assembly instructions


Add to my manuals
5 Pages

advertisement

assembly instructions | Manualzz

bulb fuse

INFINITY OPTICS

Figure 3 underside of base

Bulb replacement: (Unplug unit from power source)

Figure 3: Simply slide light housing out of the way (shown in picture) Remove the old bulb. Important: Do not touch the new halogen bulb with bare hands. Wear gloves or hold the bulb using tissue or lens paper. Body oils may damage the halogen bulb. Carefully insert prongs of replacement bulb firmly into socket. Close door and tighten screw knob.

The manufacturer warrants this instrument to be free from defects in material and workmanship under normal use for five years from the date of purchase (one year for electrical components). It does not cover damage resulting from abuse or misuse, repairs or alterations performed by other than authorized repair technicians, or damage occurring in transit. If you have questions concerning this product or warranty, contact the dealer from whom it was purchased. For warranty service, microscope should be well packed to avoid damage in transit, preferably in original box and packing. Include your complete return address and telephone number as well as a description of the difficulty, date and place of purchase, and ship to the address below. It will be repaired or replaced at no charge and returned. If misuse, alterations, accident or abnormal conditions of operation caused failure, an estimate for repairs will be provided for your approval prior to work being performed.

Woodley Equipment Company Ltd, Old Station Park Buildings, St Johns Street, Horwich, Bolton, BL6 7NY

Tel: +44(0)1204 669033 Fax: +44(0)1204 669034 Email: [email protected]

MICROSCOPE

Model MIS-6000

USER’S MANUAL

Before using this microscope, please read this manual to learn about

the available features to obtain the best results from your microscope.

WARNING: To prevent fire or shock hazard, do not expose this unit to rain or moisture.

This equipment should be used with AC 110V, 60 Hz in the USA or Canada.

CAUTION: No user-serviceable parts inside. Refer servicing to qualified service personnel.

Version 1_0811 EC

SPECIFICATIONS

Objectives: Infinity Achromatic objectives (also available with PLAN)

Objective

∞ 4X

∞ 10X

∞ 40X

∞ 100X (oil)

Eyepieces:

Numerical

Aperture (N.A.)

0.10

0.25

0.65

1.25

Working

Distance

10mm

6.92mm

0.58mm

0.1395mm

Eyepiece

10X (wide field)

Linear field of view

24mm in diameter

Total magnifying powers:

Eyepiece &

Auxiliary Lens

4X

Objective

10X 40X

10X wide field 40X 100X

100X

400X 1000X

Stage:

Size

X-direction movement range

Y-direction movement range

148x153mm 90 mm 60 mm

Abbe double lens condenser: N.A. = 1.25 with a built in graduated iris diaphragm.

Fine focusing range: 70 mm. One division is 0.002 mm.

Coarse focusing range: 70 mm.

Binocular head: Interpupillary distance between eyepiece tubes from 55 mm to 75 mm.

Magnifying power of the auxiliary lens: 1X. objective should be wiped off with a piece of soft clean cloth or lens tissue moistened

1 with xylene to remove the immersion oil immediately after using.

After using your Premiere

®

microscope, turn the dimmer control to the lowest setting and turn off the power to prolong the life of the halogen bulb. Lower the stage by rotating the coarse adjustment knob. (Release the locking ring first.) The instrument should be covered with a hood to keep dust off it or dis-assembled and stored in its styrofoam case.

MAINTENANCE

Like other optical instruments, this microscope should be kept in a cool, shady and dry place, free from dust, fumes and moisture. If not stored in its box, cover with a hood to protect from dust.

Since all lenses have been carefully aligned, it is not desirable to dismantle them at random. If there is any dirt settled on them, wipe it off gently with some absorbent cotton moistened with lens cleaner. If alcohol is used, be careful not to let it penetrate through the lenses and dissolve the gumming. Any dust settled on the lenses can be blown away with an air blower or wiped off with a clean soft camel hair brush. In cleaning mechanical parts and applying non-corrosive lubricant, take special care not to touch the optical elements, especially the objective lenses.

When dis-assembling the microscope for storage, always put the covers into the eyepiece tubes and objective apertures to prevent dust settling inside the microscope lenses.

The 100X oil immersion objective should be wiped off with a piece of soft clean cloth or lens tissue moistened with xylene immediately after using.

1

8

6

2

14

13

10

5

11

15

12

9

16

3

17 7

6

4

Figures 1 & 2. The Structure of MIS-6000 Microscope

1. Eyepiece

2. Graduated Diopter Ring

3. X-Direction Movement Knob

4. Y-Direction Movement Knob

5. Moveable Spring Clips

6. Fine Adjustment Knob

7. Coarse Adjustment Knob

8. Screw for Clamping the Head

9. Nosepiece

10. Objective

11. Objective Stage

12. Condenser

13. Iris Diaphragm Adjustment Lever

14. Condenser Control Knob

15. Dimmer Control for Brightness Adjustment

16. Field Diapragm/Collector Lens

17. Locking Control

ASSEMBLY INSTRUCTIONS

3

1. Remove microscope stand from box and styrofoam packing and place it on a stable work table. It is strongly recommended to keep the styrofoam and carton for possible future shipping.

2. Remove all plastic bags and covering (these can be discarded).

3. Remove binocular head from the packing.

4. Remove the plastic cap covering the neck of the microscope base. Fit the binocular head into the neck of the microscope stand. Tighten with the screw clamp as necessary. The head is 360° rotatable and can be adjusted to any position desired.

5. Unscrew the plastic aperture covers from the nosepiece. Beginning with the 4X

Objective, remove from plastic case and screw the objective into any opening in the nosepiece. Rotate nosepiece as needed and fit remaining 3 objectives into each aperture in ascending order.

6. Remove the plastic eyepiece tube covers and insert eyepieces into each eyepiece tube.

7. Attach power cord to the back of microscope and connect to power source.

Your Premiere

®

microscope is now ready for use.

OPERATING INSTRUCTIONS

Set light dimmer control to lowest intensity and switch on the power (switch at back of scope base), increasing slowly to desired level.

Begin by placing a microscope slide containing a specimen to be observed on the object stage and clamp it carefully with the movable spring clip. Adjust the interpupillary distance between the two eyepieces to the most comfortable position for the user. Adjust the Graduated Diopter Ring on the left eyepiece for maximum clarity.

Unlock the stage by moving the locking control inside the left coarse focus knob ring to the up position. Using the X and Y Direction Knobs located just below the stage

(on the right hand side) the specimen may be moved to the center of the stage for observation. Once the specimen is in focus, the X and Y Direction Knobs may be adjusted to observe different sections of the specimen.

Begin observation of your specimen with the 4X Objective. Turn the coarse focusing knob until a clear image is obtained, then use the fine focus knob to enhance the observation of the specimen to its clearest image.

The locking control can be used to lock the stage in position while examining a specimen. This can help prevent the stage from being raised enough to reach the objectives. Turn the ring so the locking control is in the up position to lock the stage.

Be sure to unlock the stage by moving the lever to the up or down position to allow the stage to travel further up when necessary.

Regulating brightness of the view: There are several ways to adjust the amount of light which is shed on a specimen, and the light will affect the observation. In most cases, a better view is obtained by the use of a colored glass filter inserted below the iris diaphragm. Slide the filter holder to the right to reveal an open ring. Insert the blue or green filter into this ring and slide the filter holder back into position under the diaphragm. The iris diaphragm below the stage can be opened (slide lever forward) or closed (slide lever back to left) to control the amount of light directed through the condenser. The condenser assembly under the stage can be shifted up or down by means of the control knob (left hand side under stage) to effectively move the light beam closer to (up) or away from (down) the specimen under observation.

Finally, the dimmer control allows the user to adjust the intensity of the halogen light.

Vary these different methods of regulating the light beam on the specimen to obtain the most effective view for your microscope needs.

When the desired view is obtained under the lowest power (4X), rotate the nosepiece to the next higher magnification (10X). The nosepiece should “click” into position. It should only be necessary to adjust the fine focus knob slightly to again have a clear view of the specimen. As the magnification is increased, the user may also find adjustments in the various methods of regulating the brightness will improve the view of the specimen.

It is important to remember when adjusting the focus that the objective should never touch the specimen. When increasing to 100X magnification, the objective will appear to be very close to the slide. Because the 100X is an oil immersion objective, a drop of cedar-wood oil or other immersion oil should be applied in the gap between the objective and the specimen. (Note: all slides should be prepared with cover slips over the specimen for observation under the 100X objective.) The 100X oil immersion

5

STANDARD OUTFIT

MIS-6000 Microscope Stand

Eyepieces: 10X (wide field)

Infinity Achromatic Objectives: 4X, 10X, 40X, 100X (oil)

Halogen replacement bulb: (12V 30W)

Replacement Fuses (0.5A 250V)

Three wire power cord

Light green and blue glass filters

Covers for protecting Objective Screw Apertures

Covers for protecting Eyepiece Tubes

Cedar-Wood Oil

Vinyl Dust Cover

1 set

1 pair

1 piece each

1 each

1 each

1 each

1 piece each

4 pieces

2 pieces

1 bottle

1 each

APPLICATION

Premiere

®

Model MIS-6000 Infinity Optics Microscopes are specially designed for clinical examination and teaching demonstrations in laboratories, colleges and medical fields. They are also ideal instruments for biological, bacteriological, pathological and pharmaceutical research. These microscopes are equipped with Infinity objectives,

10X widefield eyepieces, Abbe condenser, built-in variable light source and coarse and fine focus adjustment to give a nice sharp image. With the revolutionary Infinity optics, you have an infinite path of light range between the objectives and the eyepiece. This gives the added benefit of adding compartments to your microscope and not affecting the optics. With the Infinity optical system you get much better results especially when using phase contrast, dark field or polarized light techniques in comparison with regular achromatic objectives.

2

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement