STRIDER
ST1500
The dream PSU for computer enthusiasts
1500W continuous and 1600W peak power
100% modular cables with cable bag
Efficiency 85%~88% at 20%~100% loading with 80 PLUS Silver certification
Class-leading eight +12V rails with 110A (Peak up to 120A)
O
1500W continuous power output with 40C operating temperature
Strict ±3% voltage regulation
Silent running 135mm fan with 19dBA minimum
Japanese main capacitors
Four PCI-E 8pin, eight PCI-E 6pin, and twelve SATA connectors support
Support ATX 12V 2.3 & EPS 12V
Active PFC
SilverStone STRIDER ST1500
ATX12V / EPS 12V Switching Power Supply
With Active PFC
PS/2 1500W
This specification describes the requirements of 1500Watts switching power supply with an stretch form-factor and EPS12V, +5V standby voltage, remote on/off control, full range line input capability and forced air cooling characteristics.
1. AC INPUT
1-1. AC input requirements
The input voltage, current, and frequency requirements for continuous operation are stated below.
Table 1 AC Input Line Requirements
Iin
Power factor correction (PF)>0.95 at full load.
18----9.0
Arms
The power supply must meet inrush requirements for any rated AC voltage, during turn on at any phase of AC voltage, during a single cycle AC dropout condition, during repetitive
ON/OFF cycling of AC,and over the specified temperature range (Top). The peak inrush current shall be less than the ratings of its critical components (including input fuse, bulk rectifiers, and surge limiting device)
2. DC OUTPUT
ŔŕœŊŅņœġŔŕIJĶıı
2-1. DC voltage regulation
Parameter
+3.3V
+5V
+12V1,2,3,4,5,6,7,8
-12V
+5VSB
MIN NOM MAX
+3.20
+3.30
+3.39
+4.85
+11.64
-10.8
+4.75
+5.00
+12.00
-12.20
+5.00
+5.15
+12.36
-13.20
+5.25
Units Tolerance
Vms +/-3%
Vms
Vms
Vms
Vms
+/-3%
+/-3%
+/-10%
+5/-5%
2-2. Load ranges
Parameter
+3.3V
+5V
+12V1
+12V2
+12V3
+12V4
+12V5
+12V6
+12V7
+12V8
-12V
+5VSB
Min
0.8
0.1
0.1
0.1
0.1
0.5
0.1
0.1
0.1
0.1
0
0
Nom.
-
-
-
-
-
-
-
-
-
-
-
-
Load Range
Max
40
25
25
25
25
40
25
25
25
25
0.5
6.0
Peak
-
30
30
30
30
-
30
30
30
-
30
8
Unit
Amps
Amps
Amps
Amps
Amps
Amps
Amps
Amps
Amps
Amps
Amps
Amps
1.Maximum continuous total DC output power should not exceed 1500W.
2.Maximum c.ontinuous combined load on +3.3 VDC and +5 VDC outputs shall not exceed 280W.
3.Maximum peak total DC output power should not exceed 1600 W.
4.Peak power and current loading shall be supported for a minimum of 12 second.
5.Maximum combined current for the 12 V outputs shall be 110A.
6.Peak current for the combined 12V outputs shall be 120A.
2-3. Output Ripple
2-3-1. Ripple regulation
Parameter
+3.3V
+5V
+12V1
+12V2
+12V3
+12V4
+12V5
+12V6
+12V7
+12V8
-12V
+5VSB
2-3-2. Definition
Ripple&Noise
50
50
120
120
120
120
120
120
120
120
120
50
Unit mVp-p mVp-p mVp-p mVp-p mVp-p mVp-p mVp-p mVp-p mVp-p mVp-p mVp-p mVp-p
ŔŕœŊŅņœġŔŕIJĶıı
2-3-2. Definition
The ripple voltage of the outputs shall be measured at the pins of the output connector when terminated in the load impedance specified in figure 1. Ripple and noise are measured at the connectors with a 0.1uF ceramic capacitor and a 10uF electrolytic capacitor to simulate system loading. Ripple shall be measured under any condition of line voltage, output load, line frequency, operation temperature.
2-3-3. Ripple voltage test circuit
Power Supply
AC Hot
AC Neutral
AC Ground
V out
V return
10uF 0.1uF
Load
Scope
Figure 1. Ripple voltage test circuit
2-4. Overshoot
Any overshoot at turn on or turn off shall be less 10% of the norminal voltage value, all outputs shall be within the regulation limit of section 2.0 before issuing the power good signal of section 5.0.
2-5. Efficiency
Power supply efficiency typical > 85% at normal AC main voltage and full load on all outputs.
2-6. Remote ON/OFF control
When the logic level "PS-ON" is low, the DC outputs are to be enabled.
When the logic level is high or open collector, the DC outputs are to be disabled.
3. PROTECTION
3-1. Over current protection
The power supply shall have current limit to prevent the +3.3 V, +5 V, and +12 V outputs from exceeding the values shown in Table 28. If the current limits are exceeded the power supply shall shutdown and latch off. The latch will be cleared by toggling the PSON# signal or by an AC power interruption. The power supply shall not be damaged from repeated power cycling in this condition. -12 V and 5 VSB shall be protected under over current or shorted conditions so that no damage can occur to the power supply. All outputs shall be protected so that no damage occurs to the power supply under a shorted output condition.
Voltage
+3.3 V
+5 V
+12 V
110% minimum
110% minimum
110% minimum
150% maximum
150% maximum
150% maximum
3-2. Under voltage protection.
In an under voltage fault occurs, the supply will latch all DC outputs into a shutdown state when +12V, +5V & +3.3V outputs under 85% of it's maximum value.
3-3. Over voltage protection
The over voltage sense circuitry and reference shall reside in packages that are separate and distinct from the regulator control circuity and reference. No single point fault shall be able to cause a sustained over voltage condition on any or all outputs. The supply shall provide latch-mode over voltage protection as defined in Table.
output
+12 VDC
+5 VDC
+3.3 VDC
Minimum
13.4
5.74
3.76
Nominal
15.0
6.3
4.2
Maximum
16.6
7
4.50
Unit
Volts
Volts
Volts
ŔŕœŊŅņœġŔŕIJĶıı
3-4. Short circuit
An output short circuit is defined as any output impedance of less than 0.1 ohms.The
power supply shall shut down and latch off for shorting the +3.3 VDC,+5 VDC,or+12 VDC rails to return or any other rail. Shorts between main output rails and +5VSB shall not cause any damage to the power supply. The power supply shall either shut down and latch off or fold back for shorting the negative rails.+5VSB must be capable of being shorted indefinitely, but when the short is removed, the power supply shall recover automatically or by cycling PS_ON#.The power supply shall be capable of withstanding a continuous short-circuit to the output without damage or overstress to the unit.
3-5. No load operation
No damage or hazardous condition should occur with all the DC output connectors disconnected from the load. The power supply may latch into the shutdown state.
4. TIMING
4-1. Signal timing drawing
Figure 2. is a reference for signal timing for main power connector signals and
~
VAC on
PS-ON off
95%
+12V/+5V/+3.3V O/P
10%
T1
~
~
T6
T3
T5
~ pw-OK pw-OK Sense level=95% of nominal
T2
T4
Figure 2. PW-OK Timing Sequence
(1)T3: Power good signal turn on delay time (100ms~500ms)
(2)T4: Power good signal turn off delay time (1ms min)
(3)T5: Rise time (5~70ms max)
(4)T6: Hold up time (16ms min)
4-2. Hold up time
When the power loss its input power, it shall maintain 17ms in regulation limit at normal input voltage. (AC:115V/60Hz or 230V/50Hz)
5. ENVIRONMENT
5-1. Operation
Temperature
Relative Humidity
0 to 40
10 to 85%, non-condensing
5-2. Shipping and Storage
Temperature
Relative Humidity
5.3 Altitude
Operating
Storage
-40 to 70
5 to 90%, non-condensing
10,000FT max
50,000FT max
6. SAFETY
6-1. Underwriters Laboratory (UL) recognition.
The power supply designed to meet UL
6-2. The power supply must bear the German Bauart Mark from TUV
ŔŕœŊŅņœġŔŕIJĶıı
7. ELECTROMAGNETIC COMPATIBILITY (EMC)
7-1. IEC 1000-4-2 ESD LEVEL X20KV4.
7-2. IEC 1000-4-3 radiated electrical field requirement.
7-3. IEC 1000-4-4 BURST.
7-4. IEC 1000-4-5 surge Voltages.
7-5. EN61000-3-2 harmonic current emissions.
If applicable to sales in Japan or Europe, the power supply shall meet the requirements of EN 61000-3-2 class D and the guidelines for the suppression of harmonics in appliances and general use equipment class D for harmonic line current content at full-rated power.
7-6. EN55024 class B radio interference (CISPR 22)
7-7. FCC part 15, subpart J class B 115VAC operation.
8. MTBF
8-1. MTBF (mean time between failures) calculation
The demonstrated MTBF shall be 100,000 hours of continuous operation at 25 ,full load,and nominal line. The MTBF of the power supply be calculated in accordance with
MIL-HDBK-217F. The DC FAN is not included.
9-1. Physical dimension
150 mm (W) × 86 mm (H) × 220 mm (D)
9-2. Connectors(Pin definition)
M/B 24PIN connector
Pin
White
Red
Red
Red
Red
Black
Orange
Orange
Blue
Black
Green
Black
Black
Black
Signal
+3.3V
+3.3Vsense
-12VDC
COM
PS-ON
COM
COM
COM
N/C
+5VDC
+5VDC
+5Vsense
+5VDC
COM
Pin
20
21
22
22
23
24
16
17
18
19
13
13
14
15
Signal
7
8
9
5
6
3
4
1 +3.3V
2 +3.3V
COM
+5VDC
COM
+5VDC
Orange
COM
PWRGOOD
+5Vsb
+3.3V
COM
+5VDC
COM
+5VDC
COM
PWRGOOD
+5Vsb
10 +12V3 Yellow
11
12
+12V3
+3.3V
+12V3
+3.3V
Yellow
Yellow
Yellow
Yellow
EPS 12V 8PIN connector #1 & #2
Signal
+12V2
+12V2
+12V1
+12V1
Pin
7
8
5
6
Pin
3
4
1
2
Signal
COM
COM
COM
COM
Black
Black
Black
Black
Black
Black
ATX 12V 4PIN (4+4PIN EPS 12V in split mode)
Signal
GND
GND
Pin
1
2
Pin
3
4
Signal
+12V1/2
+12V1/2
Yellow
Yellow
ŔŕœŊŅņœġŔŕIJĶıı
4PIN peripheral connector (HDD) 4PIN floppy connector (FDD)
Signal Pin Pin Signal
Yellow
Black
Black
Red
+12V3/4
COM
COM
+5VDC
3
4
1
2
3
4
1
2
+5VDC
COM
COM
+12V3/4
Red
Black
Black
Yellow
SATA connector
Signal
Orange
Black
Red
Black
Yellow/White stripe
+3.3V
COM
+5V
COM
+12V4
Pin
5
4
3
2
1
Yellow
Yellow
Yellow
Black sense1
8PIN PCI Express connector #1 & #2 & #3 & #4
Signal
+12V5/6/7/8
+12V5/6/7/8
+12V5/6/7/8
COM
Pin
1
2
3
4
Pin
5
6
7
8
Signal
COM
COM
COM
COM
Black
Black
Black
Black
6PIN PCI Express connector #1 & #2 & #3 & #4 & #5 & #6 & #7 & #8
Yellow
Yellow
Yellow
Signal
+12V5/6/7/8
+12V5/6/7/8
+12V5/6/7/8
Pin
1
2
3
Pin
4
5
6
Signal
COM
COM
COM
Black
Black
Black
advertisement