STRIDER

ST1500

The dream PSU for computer enthusiasts

1500W continuous and 1600W peak power

100% modular cables with cable bag

Efficiency 85%~88% at 20%~100% loading with 80 PLUS Silver certification

Class-leading eight +12V rails with 110A (Peak up to 120A)

O

1500W continuous power output with 40C operating temperature

Strict ±3% voltage regulation

Silent running 135mm fan with 19dBA minimum

Japanese main capacitors

Four PCI-E 8pin, eight PCI-E 6pin, and twelve SATA connectors support

Support ATX 12V 2.3 & EPS 12V

Active PFC

SilverStone STRIDER ST1500

ATX12V / EPS 12V Switching Power Supply

With Active PFC

PS/2 1500W

This specification describes the requirements of 1500Watts switching power supply with an stretch form-factor and EPS12V, +5V standby voltage, remote on/off control, full range line input capability and forced air cooling characteristics.

1. AC INPUT

1-1. AC input requirements

The input voltage, current, and frequency requirements for continuous operation are stated below.

Table 1 AC Input Line Requirements

Iin

Power factor correction (PF)>0.95 at full load.

18----9.0

Arms

The power supply must meet inrush requirements for any rated AC voltage, during turn on at any phase of AC voltage, during a single cycle AC dropout condition, during repetitive

ON/OFF cycling of AC,and over the specified temperature range (Top). The peak inrush current shall be less than the ratings of its critical components (including input fuse, bulk rectifiers, and surge limiting device)

2. DC OUTPUT

ŔŕœŊŅņœġŔŕIJĶıı

2-1. DC voltage regulation

Parameter

+3.3V

+5V

+12V1,2,3,4,5,6,7,8

-12V

+5VSB

MIN NOM MAX

+3.20

+3.30

+3.39

+4.85

+11.64

-10.8

+4.75

+5.00

+12.00

-12.20

+5.00

+5.15

+12.36

-13.20

+5.25

Units Tolerance

Vms +/-3%

Vms

Vms

Vms

Vms

+/-3%

+/-3%

+/-10%

+5/-5%

2-2. Load ranges

Parameter

+3.3V

+5V

+12V1

+12V2

+12V3

+12V4

+12V5

+12V6

+12V7

+12V8

-12V

+5VSB

Min

0.8

0.1

0.1

0.1

0.1

0.5

0.1

0.1

0.1

0.1

0

0

Nom.

-

-

-

-

-

-

-

-

-

-

-

-

Load Range

Max

40

25

25

25

25

40

25

25

25

25

0.5

6.0

Peak

-

30

30

30

30

-

30

30

30

-

30

8

Unit

Amps

Amps

Amps

Amps

Amps

Amps

Amps

Amps

Amps

Amps

Amps

Amps

1.Maximum continuous total DC output power should not exceed 1500W.

2.Maximum c.ontinuous combined load on +3.3 VDC and +5 VDC outputs shall not exceed 280W.

3.Maximum peak total DC output power should not exceed 1600 W.

4.Peak power and current loading shall be supported for a minimum of 12 second.

5.Maximum combined current for the 12 V outputs shall be 110A.

6.Peak current for the combined 12V outputs shall be 120A.

2-3. Output Ripple

2-3-1. Ripple regulation

Parameter

+3.3V

+5V

+12V1

+12V2

+12V3

+12V4

+12V5

+12V6

+12V7

+12V8

-12V

+5VSB

2-3-2. Definition

Ripple&Noise

50

50

120

120

120

120

120

120

120

120

120

50

Unit mVp-p mVp-p mVp-p mVp-p mVp-p mVp-p mVp-p mVp-p mVp-p mVp-p mVp-p mVp-p

ŔŕœŊŅņœġŔŕIJĶıı

2-3-2. Definition

The ripple voltage of the outputs shall be measured at the pins of the output connector when terminated in the load impedance specified in figure 1. Ripple and noise are measured at the connectors with a 0.1uF ceramic capacitor and a 10uF electrolytic capacitor to simulate system loading. Ripple shall be measured under any condition of line voltage, output load, line frequency, operation temperature.

2-3-3. Ripple voltage test circuit

Power Supply

AC Hot

AC Neutral

AC Ground

V out

V return

10uF 0.1uF

Load

Scope

Figure 1. Ripple voltage test circuit

2-4. Overshoot

Any overshoot at turn on or turn off shall be less 10% of the norminal voltage value, all outputs shall be within the regulation limit of section 2.0 before issuing the power good signal of section 5.0.

2-5. Efficiency

Power supply efficiency typical > 85% at normal AC main voltage and full load on all outputs.

2-6. Remote ON/OFF control

When the logic level "PS-ON" is low, the DC outputs are to be enabled.

When the logic level is high or open collector, the DC outputs are to be disabled.

3. PROTECTION

3-1. Over current protection

The power supply shall have current limit to prevent the +3.3 V, +5 V, and +12 V outputs from exceeding the values shown in Table 28. If the current limits are exceeded the power supply shall shutdown and latch off. The latch will be cleared by toggling the PSON# signal or by an AC power interruption. The power supply shall not be damaged from repeated power cycling in this condition. -12 V and 5 VSB shall be protected under over current or shorted conditions so that no damage can occur to the power supply. All outputs shall be protected so that no damage occurs to the power supply under a shorted output condition.

Voltage

+3.3 V

+5 V

+12 V

110% minimum

110% minimum

110% minimum

150% maximum

150% maximum

150% maximum

3-2. Under voltage protection.

In an under voltage fault occurs, the supply will latch all DC outputs into a shutdown state when +12V, +5V & +3.3V outputs under 85% of it's maximum value.

3-3. Over voltage protection

The over voltage sense circuitry and reference shall reside in packages that are separate and distinct from the regulator control circuity and reference. No single point fault shall be able to cause a sustained over voltage condition on any or all outputs. The supply shall provide latch-mode over voltage protection as defined in Table.

output

+12 VDC

+5 VDC

+3.3 VDC

Minimum

13.4

5.74

3.76

Nominal

15.0

6.3

4.2

Maximum

16.6

7

4.50

Unit

Volts

Volts

Volts

ŔŕœŊŅņœġŔŕIJĶıı

3-4. Short circuit

An output short circuit is defined as any output impedance of less than 0.1 ohms.The

power supply shall shut down and latch off for shorting the +3.3 VDC,+5 VDC,or+12 VDC rails to return or any other rail. Shorts between main output rails and +5VSB shall not cause any damage to the power supply. The power supply shall either shut down and latch off or fold back for shorting the negative rails.+5VSB must be capable of being shorted indefinitely, but when the short is removed, the power supply shall recover automatically or by cycling PS_ON#.The power supply shall be capable of withstanding a continuous short-circuit to the output without damage or overstress to the unit.

3-5. No load operation

No damage or hazardous condition should occur with all the DC output connectors disconnected from the load. The power supply may latch into the shutdown state.

4. TIMING

4-1. Signal timing drawing

Figure 2. is a reference for signal timing for main power connector signals and

~

VAC on

PS-ON off

95%

+12V/+5V/+3.3V O/P

10%

T1

~

~

T6

T3

T5

~ pw-OK pw-OK Sense level=95% of nominal

T2

T4

Figure 2. PW-OK Timing Sequence

(1)T3: Power good signal turn on delay time (100ms~500ms)

(2)T4: Power good signal turn off delay time (1ms min)

(3)T5: Rise time (5~70ms max)

(4)T6: Hold up time (16ms min)

4-2. Hold up time

When the power loss its input power, it shall maintain 17ms in regulation limit at normal input voltage. (AC:115V/60Hz or 230V/50Hz)

5. ENVIRONMENT

5-1. Operation

Temperature

Relative Humidity

0 to 40

10 to 85%, non-condensing

5-2. Shipping and Storage

Temperature

Relative Humidity

5.3 Altitude

Operating

Storage

-40 to 70

5 to 90%, non-condensing

10,000FT max

50,000FT max

6. SAFETY

6-1. Underwriters Laboratory (UL) recognition.

The power supply designed to meet UL

6-2. The power supply must bear the German Bauart Mark from TUV

ŔŕœŊŅņœġŔŕIJĶıı

7. ELECTROMAGNETIC COMPATIBILITY (EMC)

7-1. IEC 1000-4-2 ESD LEVEL X20KV4.

7-2. IEC 1000-4-3 radiated electrical field requirement.

7-3. IEC 1000-4-4 BURST.

7-4. IEC 1000-4-5 surge Voltages.

7-5. EN61000-3-2 harmonic current emissions.

If applicable to sales in Japan or Europe, the power supply shall meet the requirements of EN 61000-3-2 class D and the guidelines for the suppression of harmonics in appliances and general use equipment class D for harmonic line current content at full-rated power.

7-6. EN55024 class B radio interference (CISPR 22)

7-7. FCC part 15, subpart J class B 115VAC operation.

8. MTBF

8-1. MTBF (mean time between failures) calculation

The demonstrated MTBF shall be 100,000 hours of continuous operation at 25 ,full load,and nominal line. The MTBF of the power supply be calculated in accordance with

MIL-HDBK-217F. The DC FAN is not included.

9-1. Physical dimension

150 mm (W) × 86 mm (H) × 220 mm (D)

9-2. Connectors(Pin definition)

M/B 24PIN connector

Pin

White

Red

Red

Red

Red

Black

Orange

Orange

Blue

Black

Green

Black

Black

Black

Signal

+3.3V

+3.3Vsense

-12VDC

COM

PS-ON

COM

COM

COM

N/C

+5VDC

+5VDC

+5Vsense

+5VDC

COM

Pin

20

21

22

22

23

24

16

17

18

19

13

13

14

15

Signal

7

8

9

5

6

3

4

1 +3.3V

2 +3.3V

COM

+5VDC

COM

+5VDC

Orange

COM

PWRGOOD

+5Vsb

+3.3V

COM

+5VDC

COM

+5VDC

COM

PWRGOOD

+5Vsb

10 +12V3 Yellow

11

12

+12V3

+3.3V

+12V3

+3.3V

Yellow

Yellow

Yellow

Yellow

EPS 12V 8PIN connector #1 & #2

Signal

+12V2

+12V2

+12V1

+12V1

Pin

7

8

5

6

Pin

3

4

1

2

Signal

COM

COM

COM

COM

Black

Black

Black

Black

Black

Black

ATX 12V 4PIN (4+4PIN EPS 12V in split mode)

Signal

GND

GND

Pin

1

2

Pin

3

4

Signal

+12V1/2

+12V1/2

Yellow

Yellow

ŔŕœŊŅņœġŔŕIJĶıı

4PIN peripheral connector (HDD) 4PIN floppy connector (FDD)

Signal Pin Pin Signal

Yellow

Black

Black

Red

+12V3/4

COM

COM

+5VDC

3

4

1

2

3

4

1

2

+5VDC

COM

COM

+12V3/4

Red

Black

Black

Yellow

SATA connector

Signal

Orange

Black

Red

Black

Yellow/White stripe

+3.3V

COM

+5V

COM

+12V4

Pin

5

4

3

2

1

Yellow

Yellow

Yellow

Black sense1

8PIN PCI Express connector #1 & #2 & #3 & #4

Signal

+12V5/6/7/8

+12V5/6/7/8

+12V5/6/7/8

COM

Pin

1

2

3

4

Pin

5

6

7

8

Signal

COM

COM

COM

COM

Black

Black

Black

Black

6PIN PCI Express connector #1 & #2 & #3 & #4 & #5 & #6 & #7 & #8

Yellow

Yellow

Yellow

Signal

+12V5/6/7/8

+12V5/6/7/8

+12V5/6/7/8

Pin

1

2

3

Pin

4

5

6

Signal

COM

COM

COM

Black

Black

Black

advertisement