TP600 and TP400 Control Panels


Add to my manuals
25 Pages

advertisement

TP600 and TP400 Control Panels | Manualzz

TP600 and TP400 Control Panels

Balboa Water Group Revolution Series

User Interface and Programming Reference – Standard Menus

System Model:

Software Version:

Panel Model:

Software Version:

BP1500 / BP1600 - Other BP-Series Systems as required.

7.0 and later

TP600 Series

2.3 or later

TP400 Series

2.4 or later

JETS AUX LIGH T H

Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,

Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. All material copyright of Balboa Water Group.

40940_I

1

05-08-12

Main Menus

Navigation

Navigating the entire menu structure is done with 2 or 3 buttons on the control panel.

Some panels have separate WARM (Up) and COOL (Down) buttons, while others have a single Temperature button. In the navigation diagrams

Temperature buttons are indicated by a single button icon.

Panels that have two Temperature buttons (Warm and Cool) can use both of them to simplify navigation and programming where a single Temperature icon is shown.

The LIGHT Button is also used to choose the various menus and navigate each section.

Typical use of the Temperature button(s) allows changing the

Set Temperature while the numbers are fl ashing in the LCD.

Pressing the LIGHT button while the numbers are fl ashing will enter the menus.

The menus can be exited with certain button presses. Simply waiting for several seconds will return the panel operation to normal.

Power-up Screens

Each time the System powers up, a series of numbers is displayed.

After the startup sequence of numbers, the system will enter Priming Mode (See Page 3).

Key

Indicates Flashing or Changing Segment

Indicates Alternating or Progressive Message - every 1/2 second

A temperature button, used for “Action”

Light or dedicated “Choose” button, depending on control panel configuration

Waiting time that keeps the last change to a menu item.

*****

Waiting time (depends on menu item) that reverts to original setting and ignores any change to that menu item.

Main Screen

While the Temperature is still flashing, press Light.

READY RANGE FLTR1 SET RANGE

Light Cycle if enabled

Indicates a Menu Item that

Depends on a Manufacturer

Configuration and may or may not appear.

SET RANGE

SET READY SET

1

2

SET

P

If Time of Day is not set

“SET TIME” will appear in this menu.

Main Screen

READY RANGE FLTR1

Waiting Several Seconds in the Main Menu will allow the display to revert to the Main Screen.

Most changes are not saved unless Light is pressed.

Refer to Key above.

Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,

Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. All material copyright of Balboa Water Group.

40940_I

2

05-08-12

Fill it up!

Preparation and Filling

Fill the spa to its correct operating level. Be sure to open all valves and jets in the plumbing system before fi lling to allow as much air as possible to escape from the plumbing and the control system during the fi lling process.

After turning the power on at the main power panel, the top-side panel display will go through specifi c sequences. These sequences are normal and display a variety of information regarding the confi guration of the hot tub control.

Priming Mode – M019*

This mode will last for 4-5 minutes or you can manually exit the priming mode after the pump(s) have primed.

Regardless of whether the priming mode ends automatically or you manually exit the priming mode, the system will automatically return to normal heating and fi ltering at the end of the priming mode. During the priming mode, the heater is disabled to allow the priming process to be completed without the possibility of energizing the heater under low-fl ow or no-fl ow conditions. Nothing comes on automatically, but the pump(s) can be energized by pushing the “Jet” buttons.

If the spa has a Circ Pump, it can be activated by pressing the “Light” button during Priming Mode.

Priming the Pumps

As soon as the above display appears on the panel, push the “Jet” button once to start Pump 1 in low-speed and then again to switch to high-speed. Also, push the Pump 2 or “Aux” button, if you have a 2nd pump, to turn it on. The pumps will now be running in high-speed to facilitate priming. If the pumps have not primed after 2 minutes, and water is not fl owing from the jets in the spa, do not allow the pumps to continue to run. Turn off the pumps and repeat the process.

Note: Turning the power off and back on again will initiate a new pump priming session. Sometimes momentarily turning the pump off and on will help it to prime. Do not do this more than 5 times. If the pump(s) will not prime, shut off the power to the spa and call for service.

Important: A pump should not be allowed to run without priming for more than 2 minutes. Under NO circumstances should a pump be allowed to run without priming beyond the end of the 4-5 minute priming mode. Doing so may cause damage to the pump and cause the system to energize the heater and go into an overheat condition.

Exiting Priming Mode

You can manually exit Priming Mode by pressing a “Temp” button (Up or Down). Note that if you do not manually exit the priming mode as described above, the priming mode will be automatically terminated after 4-5 minutes. Be sure that the pump(s) have been primed by this time.

Once the system has exited Priming Mode, the top-side panel will momentarily display the set temperature but the display will not show the temperature yet, as shown below. This is because the system requires approximately 1 minute of water or

READY RANGE READY RANGE

fl owing through the heater to determine the water temperature and display it.

*M019 is a Message Code. See Page 15.

Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,

Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. All material copyright of Balboa Water Group.

40940_I

3

05-08-12

Spa Behavior

Pumps

Press the “Jets 1” button once to turn pump 1 on or off, and to shift between low- and high-speeds if equipped.

If left running, the pump will turn off after a time-out period. The pump 1 low-speed will time out after 30 minutes. The high-speed will time out after 15 minutes.

On non-circ systems, the low-speed of pump 1 runs when the blower or any other pump is on. If the spa is in Ready Mode

(See page 6), Pump 1 low may also activate for at least 1 minute every 30 minutes to detect the spa temperature (polling) and then to heat to the set temperature if needed. When the low-speed turns on automatically, it cannot be deactivated from the panel, however the high speed may be started.

Circulation Pump Modes

If the system is equipped with a circ pump, it will be confi gured to work in one of three different ways:

1, The circ pump operates continuously (24 hours) with the exception of turning off for 30 minutes at a time when the water temperature reaches 3°F (1.5°C) above the set temperature (most likely to happen in very hot climates).

2, The circ pump stays on continuously, regardless of water temperature.

3, A programmable circ pump will come on when the system is checking temperature (polling), during fi lter cycles, during freeze conditions, or when another pump is on.

The specifi c Circulation Mode that is used has been determined by the Manufacturer and cannot be changed in the fi eld.

Filtration and Ozone

On non-circ systems, Pump 1 low and the ozone generator will run during fi ltration. On circ systems, the ozone will run with the circ pump.

The system is factory-programmed with one fi lter cycle that will run in the evening (assuming the time-of-day is properly set) when energy rates are often lower. The fi lter time and duration are programmable. (See page 10)

A second fi lter cycle can be enabled as needed.

At the start of each fi lter cycle, the blower (if there is one) or Pump 2 (if there is one) will run briefl y to purge its plumbing to maintain good water quality.

Freeze Protection

If the temperature sensors within the heater detect a low enough temperature, then the pump(s) and the blower automatically activate to provide freeze protection. The pump(s) and blower will run either continuously or periodically depending on conditions.

In colder climates, an optional additional freeze sensor may be added to protect against freeze conditions that may not be sensed by the standard sensors. Auxiliary freeze sensor protection acts similarly except with the temperature thresholds determined by the switch. See your dealer for details.

Clean-up Cycle (optional)

When a pump or blower is turned on by a button press, a clean-up cycle begins 30 minutes after the pump or blower is turned off or times out. The pump and the ozone generator will run for 30 minutes or more, depending on the system. On some systems, you can change this setting. (See the Preferences section on page 12)

Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,

Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. All material copyright of Balboa Water Group.

40940_I

4

05-08-12

Temperature and Temp Range

Adjusting the Set Temperature

When using a panel with Up and Down buttons (Temperature buttons), pressing Up or Down will cause the temperature to fl ash. Pressing a temperature button again will adjust the set temperature in the direction indicated on the button. When the LCD stops fl ashing, the spa will heat to the new set temperature when required.

If the panel has a single temperature button, pressing the button will cause the temperature to fl ash. Pressing the button again will cause the temperature to change in one direction (e.g. UP). After allowing the display to stop fl ashing, pressing the Temperature Button will cause the temperature to fl ash and the next press will change the temperature in the opposite direction (e.g. DOWN).

Press-and-Hold

If a Temperature button is pressed and held when the temperature is fl ashing, the temperature will continue to change until the button is released. If only one temperature button is available and the limit of the Temperature Range is reached when the button is being held, the progression will reverse direction.

Dual Temperature Ranges

This system incorporates two temperature range settings with independent set temperatures. The High Range designated in the display by an “up” arrow, and the Low Range designated in the display by a “down” arrow.

These ranges can be used for various reasons, with a common use being a “ready to use” setting vs. a “vacation” setting.

The Ranges are chosen using the menu structure below. Each range maintains its own set temperature as programmed by the user. This way, when a range is chosen, the spa will heat to the set temperature associated with that range.

For example:

High Range might be set between 80°F and 104°F.

Low Range might be set between 50°F and 99°F.

More specifi c Temp Ranges may be determined by the Manufacturer.

Freeze Protection is active in either range.

See Ready and Rest on Page 6 for additional heating control information.

Key

Indicates Flashing or Changing Segment

Indicates Alternating or Progressive Message - every 1/2 second

A temperature button, used for “Action”

Light or dedicated “Choose” button, depending on control panel configuration

Waiting time that keeps the last change to a menu item.

*****

Waiting time (depends on menu item) that reverts to original setting and ignores any change to that menu item.

Main Screen

Set Temp will Show & Flash Press a Temp Button repeatedly to change the temperature.

Main Screen

READY RANGE FLTR1 SET

High-Range vs.

Low-Range Temp Choice

While temperature is flashing...

RANGE SET RANGE SET RANGE

OR

Several Seconds

Pressing and holding a Temp Button will also change the temperature.

READY

Toggle the Range arrows in the LCD.

To Set

Main Screen

RANGE FLTR1

SET RANGE SET RANGE

READY

Several Seconds

Reverts to Original Setting

RANGE FLTR1

To next item in Main Menu

Main Screen

READY RANGE FLTR1

Set Temp will Show & Flash

SET

Press a Temp Button repeatedly to change the temperature.

Main Screen

RANGE FLTR1 SET RANGE FLTR1 SET RANGE FLTR1

OR

Several Seconds

Pressing and holding a Temp Button will also change the temperature.

READY RANGE FLTR1

Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,

Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. All material copyright of Balboa Water Group.

40940_I

5

05-08-12

Mode – Ready and Rest

In order for the spa to heat, a pump needs to circulate water through the heater. The pump that performs this function is known as the “heater pump.”

The heater pump can be either a 2-Speed Pump 1 or a circulation pump.

If the heater pump is a 2-Speed Pump 1, READY Mode will circulate water every 1/2 hour, using Pump 1 Low, in order to maintain a constant water temperature, heat as needed, and refresh the temperature display. This is known as “polling.”

REST Mode will only allow heating during programmed fi lter cycles. Since polling does not occur, the temperature display may not show a current temperature until the heater pump has been running for a minute or two.

Circulation Mode (See Page 4, under Pumps, for other circulation modes)

If the spa is confi gured for 24HR circulation, the heater pump generally runs continuously. Since the heater pump is always running, the spa will maintain set temperature and heat as needed in Ready Mode, without polling.

In Rest Mode, the spa will only heat to set temperature during programmed fi lter times, even though the water is being fi ltered constantly when in Circulation Mode.

Main Screen

READY RANGE FLTR1

SET READY

To next item in

Main Menu

If not toggled

Main Screen

SET RANGE

While the Temperature is still flashing, press Light repeatedly until MODE appears in the LCD.

Main Screen

To Set

Key

Indicates Flashing or Changing Segment

Indicates Alternating or Progressive Message - every 1/2 second

A temperature button, used for “Action”

Light or dedicated “Choose” button, depending on control panel configuration

Waiting time that keeps the last change to a menu item.

*****

Waiting time (depends on menu item) that reverts to original setting and ignores any change to that menu item.

SET REST

Several Seconds

Reverts to Original Setting

REST RANGE FLTR1

Toggle between READY and REST

Pressing Light when the display is toggled will go to Main Screen.

READY Mode will allow the spa to Poll and determine a need for heat. The panel will maintain a “current” temperature display.

REST Mode will not Poll and will only heat during filter cycles. The panel will not display a current temperature at all times.

REST RANGE FLTR1

1 Hour

REST RANGE REST RANGE REST RANGE REST RANGE

The Main Screen will display RUN PUMP FOR TEMP if the filtration pump has not run for over 1 hour.

The Main Screen will display normally during Filter Cycles or when the spa is in use.

If the filtration pump has been off for an hour or more, when any function button, EXCEPT Light, is pressed on the panel, the pump used in conjuncton with the heater will run so that temperature can be sensed and displayed.

REST RANGE

Ready-in-Rest Mode

READY/REST appears in the display if the spa is in Rest Mode and Jet 1 is pressed. It is assumed that the spa is being used and will heat to set temperature. While Pump 1 High can be turned on and off, Pump 1 Low will run until set temperature is reached, or 1 hour has passed. After 1 hour, the System will revert to Rest Mode. This mode can also be reset by entering the Mode Menu and changing the Mode.

Main Screen Main Screen

J

READY/REST RANGE REST RANGE

Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,

Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. All material copyright of Balboa Water Group.

40940_I

6

05-08-12

Show and Set Time-of-Day

Be sure to set the Time-of-Day

Setting the time-of-day can be important for determining fi ltration times and other background features.

When in the TIME menu, SET TIME will fl ash on the display if no time-of-day is set in the memory.

24-hour time display can be set under the PREF menu. (See Page 10)

READY

Main Screen

RANGE FLTR1 SET RANGE

While the Temperature is still flashing, press Light repeatedly until TIME appears in the LCD.

Key

Indicates Flashing or Changing Segment

Indicates Alternating or Progressive Message - every 1/2 second

A temperature button, used for “Action”

Light or dedicated “Choose” button, depending on control panel configuration

Main Screen

Waiting time that keeps the last change to a menu item.

*****

Waiting time (depends on menu item) that reverts to original setting and ignores any change to that menu item.

P

Several Seconds

READY RANGE FLTR1

To next item in

Main Menu

SET P SET P SET P SET

Main Screen

To Set

P READY

Several Seconds

Reverts to Original Setting

RANGE FLTR1

If Time of Day is not actually programmed due to a power cycle,

SET TIME will appear in the menu instead of just TIME.

P

Note:

If power is interrupted to the system, Time-of-Day is not stored. The system will still operate and all other user settings will be stored. If fi lter cycles are required to run at a particular time of day, resetting the clock will return the fi lter times to the actual programmed periods.

When the system starts up, it defaults to 12:00 Noon, so another way to get fi lter times back to normal is to start up the spa at noon on any given day. SET TIME will still fl ash in the TIME Menu until the time is actually set, but since the spa started at noon, the fi lter cycles will run as programmed.

Flip (Invert Display)

Main Screen

SET

READY RANGE FLTR1 SET RANGE

While the Temperature is still flashing, press Light repeatedly until FLIP appears in the LCD.

Main Screen or

Several Seconds

SET

READY RANGE FLTR1

Toggle the inversion of the segmented characters

Pressing Light when the display is toggled will go to Main Screen.

To next item in

Main Menu

If not toggled

Note:

Some panels may have a dedicated FLIP button, which allows the user to fl ip the display with a single button-press.

Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,

Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. All material copyright of Balboa Water Group.

40940_I

7

05-08-12

Restricting Operation

The control can be restricted to prevent unwanted use or temperature adjustments.

Locking the panel prevents the controller from being used, but all automatic functions are still active.

Locking the Temperature allows Jets and other features to be used, but the Set Temperature and other programmed settings cannot be adjusted.

Temperature Lock allows access to a reduced selection of menu items.

These include Set Temperature, FLIP, LOCK, UTIL, INFO and FALT LOG.

Main Screen

READY RANGE FLTR1 SET RANGE

While the Temperature is still flashing, press Light repeatedly until LOCK appears in the LCD.

Key

Indicates Flashing or Changing Segment

Indicates Alternating or Progressive Message - every 1/2 second

A temperature button, used for “Action”

Light or dedicated “Choose” button, depending on control panel configuration

Locks Temp. and Settings.

Locks all function buttons.

Waiting time that keeps the last change to a menu item.

*****

Waiting time (depends on menu item) that reverts to original setting and ignores any change to that menu item.

SET SET SET

Several Seconds

To next item in

Main Menu

Main Screen

To Set

SET SET

Panel Locked

Main Screen Main Screen

READY

Several Seconds

Reverts to Original Setting

RANGE FLTR1

READY RANGE FLTR1

Any

Button

Press

READY RANGE FLTR1

Several

Seconds

READY RANGE FLTR1

Temperature Locked

Main Screen

LOCK will remain on the display for 3 seconds and then revert to the normal display.

Main Screen

READY RANGE FLTR1

Several

Seconds

RANGE

READY RANGE FLTR1

READY RANGE FLTR1

When the Temperature is locked, the panel will display the Set Temperature by pressing a Temperature Button, as ususal.

LOCK will appear if an attempt to reset the temperature is made with a subsequent button press.

Adjustable settings in the menus are also locked.

Other function buttons will operate normally.

Unlocking

This Unlock sequence may be used from any screen that may be displayed on a restricted panel.

While pressing and holding the Temperature Button (or UP button, if available),

Slowly press and release the Light Button two times.

Main Screen

A Few

Seconds

READY RANGE FLTR1

NOTE: If the panel has both an UP and a Down button, the ONLY button that will work in the Unlock Sequence is the UP button.

Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,

Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. All material copyright of Balboa Water Group.

40940_I

8

05-08-12

Hold (Standby)

Hold Mode – M037*

Hold Mode is used to disable the pumps during service functions like cleaning or replacing the fi lter. Hold Mode will last for

1 hour unless the mode is exited manually.

Drain Mode

Some spas have a special feature that allows a pump to be employed when draining the water.

When available, this feature is a component of Hold Mode.

Main Screen

READY RANGE FLTR1 SET RANGE

Main Screen

While the Temperature is still flashing, press Light repeatedly until HOLD appears in the LCD.

Several Seconds

READY RANGE FLTR1 SET

To next item in

Main Menu

Key

Indicates Flashing or Changing Segment

Indicates Alternating or Progressive Message - every 1/2 second

A temperature button, used for “Action”

Light or dedicated “Choose” button, depending on control panel configuration

Waiting time that keeps the last change to a menu item.

*****

Waiting time (depends on menu item) that reverts to original setting and ignores any change to that menu item.

Indicates a Menu Item that

Depends on a Manufacturer

Configuration and may or may not appear.

OR

Press JET Button for Pump Out/Drain, only if Drain Mode is enabled.

Some spas will allow

PUMP ING OUT (Drain Mode) with Jet 1 button

Jet 1 will toggle pump on and off.

J

3 Seconds

Main Screen

READY RANGE FLTR1

M037 is a Message Code. See Page 15.

Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,

Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. All material copyright of Balboa Water Group.

40940_I

9

05-08-12

Adjusting Filtration

Main Filtration

Filter cycles are set using a start time and a duration. Start time is indicated by an “A” or “P” in the bottom right corner of the display. Duration has no “A” or “P” indication. Each setting can be adjusted in 15-minute increments. The panel calculates the end time and displays it automatically.

Key

Main Screen

Indicates Flashing or Changing Segment

Indicates Alternating or Progressive Message - every 1/2 second

A temperature button, used for “Action”

Light or dedicated “Choose” button, depending on control panel configuration

READY RANGE FLTR1 SET RANGE

While the Temperature is still flashing, press Light repeatedly until FLTR 1 appears in the LCD.

Waiting time that keeps the last change to a menu item.

*****

Waiting time (depends on menu item) that reverts to original setting and ignores any change to that menu item.

Shows/flashes start time Sets start hour Selects minutes Sets 15-minute increments

Waiting

Several Seconds

Reverts to Original Setting

*****

SET FLTR1 P

1 FLTR1

SET FLTR1 P SET FLTR1 P SET FLTR1 P

to show RUN HRS

FLTR1 FLTR1

Sets Filter 1 length in hours

SET FLTR1

Selects part of an hour

SET FLTR1

Sets 15-minute increments

Wait to

Revert

*****

SET FLTR1

to show F1 ENDS xx:xx

To Set

A

To Set

*****

Waiting several seconds will lose any new Filter 1

Start Time and Run Hours and revert to the previous Filter 1 settings.

READY

Main Screen

RANGE FLTR1

To next item in

Main Menu

2 SET

To Set

FLTR 2

FLTR 2

to show RUN HRS

SET FLTR 2

Shows/flashes start time

Waiting

Several Seconds

Reverts to Original Setting

*****

To Set

Sets start hour

SET FLTR 2 P

Main Screen

READY RANGE FLTR1

Selects minutes

SET FLTR 2 P SET FLTR 2 P

Sets Filter 1 length in hours Selects part of an hour

Sets 15-minute increments Waiting

Several Seconds

Reverts to Original Setting

*****

SET FLTR 2 P

Sets 15-minute increments

Wait to

Revert

*****

SET FLTR 2 FLTR 2 FLTR 2 SET FLTR 2 SET FLTR 2

to show F1 ENDS xx:xx

To Set

Filter Cycle 2 - Optional Filtration

Filter Cycle 2 is OFF by default.

It is possible to overlap Filter Cycle 1 and Filter Cycle 2, which will shorten overall fi ltration by the overlap amount.

A

To Set

*****

Waiting several seconds will lose any new Filter 2 On/OFF,

Start Time and Run Hours and revert to any previous Filter 2 settings.

READY

Main Screen

RANGE FLTR1

Purge Cycles

In order to maintain sanitary conditions, secondary Pumps and/or a Blower will purge water from their respective plumbing by running briefl y at the beginning of each fi lter cycle.

If Filter Cycle 1 is set for 24 hours, enabling Filter Cycle 2 will initiate a purge when Filter Cycle 2 is programmed to begin.

Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,

Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. All material copyright of Balboa Water Group.

40940_I

10

05-08-12

Light Timer Programming

Light Timer Option

If LITE TIMR does not appear in the Main Menu, the Light Timer feature is not enabled by the manufacturer.

When available, the Light Timer is OFF by default.

Main Screen

READY RANGE FLTR1 SET RANGE

While the Temperature is still flashing, press Light repeatedly until LITE TIMR appears in the LCD.

Key

Indicates Flashing or Changing Segment

Indicates Alternating or Progressive Message - every 1/2 second

A temperature button, used for “Action”

Light or dedicated “Choose” button, depending on control panel configuration

Waiting time that keeps the last change to a menu item.

*****

Waiting time (depends on menu item) that reverts to original setting and ignores any change to that menu item.

Indicates a Menu Item that

Depends on a Manufacturer

Configuration and may or may not appear.

To next item in

Main Menu

SET

To Set

To Set

Main Screen to show RUN HRS

SET

Shows/flashes start time

Waiting

Several Seconds

Reverts to Original Setting

*****

To Set

Sets start hour

SET

to show TIMR ENDS xx:xx

A

READY RANGE FLTR1

Selects minutes

SET A

Sets Timer Length in hours

SET

SET

Selects part of an hour

A

Sets 15-minute increments

Waiting

Several Seconds

Reverts to Original Setting

*****

SET A

Sets 15-minute increments

Wait to

Revert

*****

SET SET

A

To Set

*****

Waiting several seconds will lose any new Lite Timer

On/OFF, Start Time and Run Hours and

READY

revert to the previous Lite Timer settings.

Main Screen

RANGE FLTR1

Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,

Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. All material copyright of Balboa Water Group.

40940_I

11

05-08-12

Preferences

F / C (Temp Display)

Change the temperature between Fahrenheit and Celsius.

12 / 24 (Time Display)

Change the clock between 12 hr and 24 hr display.

RE-MIN-DERS (Reminders)

Turn the reminder messages (like “Clean Filter”) On or Off.

CLN-UP (Cleanup)

Cleanup Cycle Duration is not always enabled, so it may not appear. When it is available, set the length of time Pump 1 will run after each use. 0-4 hours are available.

DOL-PHIN AD-DRES (Dolphin II and Dolphin III) Applies to RF Dolphin only.

(This message may not appear depending on the confi guration)

When set to 0, no addressing is used. Use this setting for a Dolphin Remote which is factory set for no address by default.

When set between 1 and 7, the number is the address. (See the Dolphin manual for details.)

Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,

Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. All material copyright of Balboa Water Group.

40940_I

12

05-08-12

Preferences

Main Screen

READY RANGE FLTR1 SET RANGE

While the Temperature is still flashing, press Light repeatedly until PREF appears in the LCD.

Key

Indicates Flashing or Changing Segment

Indicates Alternating or Progressive Message - every 1/2 second

A temperature button, used for “Action”

Light or dedicated “Choose” button, depending on control panel configuration

Waiting time that keeps the last change to a menu item.

*****

Waiting time (depends on menu item) that reverts to original setting and ignores any change to that menu item.

To next item in

Main Menu

(UTIL)

To show first item in Preferences menu

(F/C)

OR

Wait Several Seconds to

Return to Main Screen

Toggle °F and °C

To Set

Press Light for 12-24

SET SET

Toggle 12-hour clock and 24-hour clock

Revert

To Set

Toggle Yes and No

To next item in

Main Menu

(UTIL)

Press Light for REMINDERS

SET SET

Press Light for CLEAN UP

Only if Cleanup

Cycle is enabled.

Press Light

SET

to show Address Menu for Dolphin II or Dolphin III

RF Dolphin only.

SET

To view current setting and to toggle number of hours (0-4).

SET

SET SET

OR

Several Seconds

Revert

To Set

Revert

To Set

To veiw current setting and to toggle address numbers for Dolphin II or Dolphin III (0-7)

SET SET SET

Revert

To Set

Indicates a Menu Item that

Depends on a Manufacturer

Configuration and may or may not appear.

Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,

Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. All material copyright of Balboa Water Group.

40940_I

13

05-08-12

Utilities and Information

INFO (System Information sub-menu)

The System Information Menu displays various settings and identifi cation of the particular system. As each item in the menu is highlighted, the detail for that item is displayed at the bottom of the screen.

SSID (Software ID)

Displays the software ID number for the System.

MODL (System Model)

Displays the Model Number of the System.

SETP (Current Setup)

Displays the currently selected Confi guration Setup Number.

SIG (Confi guration Signature)

Displays the checksum for the system confi guration fi le.

Heater Voltage (Feature not used on CE rated systems.)

Displays the operating voltage confi gured for the heater.

Heater Wattage as Confi gured in Software (CE Systems Only.)

Displays a heater kilowatt rating as programmed into the control system software (1-3 or 3-6).

H _ (Heater Type)

Displays a heater type ID number.

SW _ (Dip Switch Settings)

Displays a number that represents the DIP switch positions of S1 on the main circuit board.

PANL (Panel Version)

Displays a number of the software in the topside control panel.

Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,

Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. All material copyright of Balboa Water Group.

40940_I

14

05-08-12

Additional Utilities

Utilities

In addition to INFO, The Utilities Menu contains the following:

GFCI (GFCI Test)

(Feature not available on CE rated systems.)

GFCI Test is not always enabled, so it may not appear. This screen allows the GFCI to be tested manually from the panel and can be used to reset the automatic test feature. If the GFCI Test Feature is reset, the device will trip within 7 days. (See

Page 17)

A / B (A/B Sensor Temperatures)

When this is set to On, the temperature display will alternate to display temperature from Sensor A and Sensor B in the heater.

FALT LOG (Fault Log)

The Fault Log is a record of the last 24 faults that can be reviewed by a service tech.

DEMO (Demo Mode)

Demo Mode is not always enabled, so it may not appear. This is designed to operate several devices in a sequence in order to demonstrate the various features of a particular hot tub.

Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,

Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. All material copyright of Balboa Water Group.

40940_I

15

05-08-12

Utilities

Main Screen

READY RANGE FLTR1 SET RANGE

To FIRST item in

Main Menu

(TEMP Range)

While the Temperature is still flashing, press Light repeatedly until UTIL (Utilities) appears in the LCD.

Key

Indicates Flashing or Changing Segment

Indicates Alternating or Progressive Message - every 1/2 second

A temperature button, used for “Action”

Light or dedicated “Choose” button, depending on control panel configuration

*****

Waiting time that keeps the last change to a menu item.

Waiting time (depends on menu item) that reverts to original setting and ignores any change to that menu item.

Start display of string. There is a 2 second delay on each number.

Start display of string. There is a 2 second delay on each number.

Start display of string. There is a slight delay on each number.

These strings will display once and return to the beginning.

Press Temperature again to display the string again.

Waiting 10 seconds will allow the screen to return to normal operation.

DIP Switch

Settings

120 or 240 VAC input power sensed by a

UL system at startup.

OR

Heater Type

3-6 or 1-3 Heater Wattage as programmed. Displayed by a

CE system at startup.

DIP Switch 1 – Test Mode Off (0) or On (1)

DIP Switch 2+3+4 = the number of HS pumps with heat

Store Settings (0) or Memory Reset (1)

N/A or Special Amperage Rule 1 or 2

Only if GFCI is enabled

Only if DEMO Mode is enabled

SET

OR

Several Seconds

Displays GFCI Test Menu

See Page 17

SET

To Set

When set to ON, Panel will display alternate readings from

Senor A and Sensor B on Main Screen

SET

Displays Fault Log

Several Seconds

Reverts to Original Setting

See Page 18

Indicates a Menu Item that

Depends on a Manufacturer

Configuration and may or may not appear.

OR

Back to normal operation

Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,

Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. All material copyright of Balboa Water Group.

40940_I

16

05-08-12

Utilities – GFCI Test Feature

Not Available on CE Rated Systems.

A GFCI is an important safety device and is required equipment on a hot tub installation.

Your spa may be equipped with a GFCI Protection feature. (UL rated systems only.) If your spa has this feature enabled by the manufacturer, the GFCI Trip Test must occur to allow proper spa function.

Within 1 to 7 days after startup, the spa will trip the GFCI to test it. (The number of days is factory programmed.) The GFCI must be reset once it has tripped. After passing the GFCI Trip Test, any subsequent GFCI trips will indicate a ground fault or other unsafe condition and the power to the spa must be shut off until a service person can correct the problem.

Key

Main Screen

Indicates Flashing or Changing Segment

Indicates Alternating or Progressive Message - every 1/2 second

A temperature button, used for “Action”

Light or dedicated “Choose” button, depending on control panel configuration

READY RANGE FLTR1 SET RANGE

While the Temperature is still flashing, press Light repeatedly until UTIL (Utilities) appears in the LCD.

Waiting time that keeps the last change to a menu item.

*****

Waiting time (depends on menu item) that reverts to original setting and ignores any change to that menu item.

To FIRST item in

Main Menu

(TEMP Range)

Only if GFCI is enabled

Indicates a Menu Item that

Depends on a Manufacturer

Configuration and may or may not appear.

One of these screens will appear.

TRIP may also appear briefly under certain circumstances.

When the GFCI trips, the spa will shut down.

After the breaker is reset, PASS will appear in this menu and the spa will operate normally.

The GFCI will be tripped at a random interval.

If the GFCI does

NOT trip, FAIL will appear and Spa will not operate.

SET

Only appears if a GFCI test has been passed.

Revert

Revert Revert

To next item in

Info Menu

(A/B°)

*****

Waiting several seconds inside the GFCI Menu will allow the screen to return to normal operation.

Forcing the GFCI Trip Test

The installer can cause the GFCI Trip Test to occur sooner by initiating it using the above menu.

The GFCI should trip within several seconds and the spa should shut down. If it does not, shut down the power and manually verify that a GFCI breaker is installed and that the circuit and spa are wired correctly. Verify the function of the GFCI with its own test button. Restore power to the spa and repeat the GFCI Trip Test.

Once the GFCI is tripped by the test, reset the GFCI and the spa will operate normally from that point. You can verify a successful test by navigating to the above menu. PASS should appear after a temp button is pressed from the GFCI screen.

The end-user must be trained to expect this one-time test to occur and how to properly reset the GFCI.

Warning:

If freezing conditions exist, a GFCI should be reset immediately or spa damage could result. The end user should always trained to test and reset the

GFCI on a regular basis.

Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,

Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. All material copyright of Balboa Water Group.

40940_I

17

05-08-12

Utilities – Fault Log

A Little History can tell a lot

The Fault Log stores up to 24 events in memory and they can be reviewed under the Fault Log Menu.

Each event captures a Fault Message Code, how many days have passed since the fault, Time of the fault, Set Temperature during the fault, and Sensor A and B temperatures during the fault.

Main Screen

READY RANGE FLTR1 SET RANGE

While the Temperature is still flashing, press Light repeatedly until UTIL (Utilities) appears in the LCD.

Key

Indicates Flashing or Changing Segment

Indicates Alternating or Progressive Message - every 1/2 second

A temperature button, used for “Action”

Light or dedicated “Choose” button, depending on control panel configuration

Waiting time - varies depending on function

To FIRST item in

Main Menu

(TEMP Range)

Press Light repeatedly until FALT LOG appears in the LCD.

M: Message Code

Indicates a Menu Item that

Depends on a Manufacturer

Configuration and may or may not appear.

SET

Only if DEMO Mode is enabled

READY RANGE READY

D: Days Ago

RANGE

M:

READY RANGE

24 Fault messages is the maximum.

Fewer messages may be displayed.

M:

READY RANGE

Set Temperature

READY RANGE

READY

Time

RANGE

P

M:

Sensor A Temp

READY RANGE

The Fault Log is also available from the

Test Menu (in Test Mode).

Sensor B Temp

Waiting several seconds inside the Fault Log Menu will allow the screen to return to normal operation.

See following pages for various Message Codes and defi nitions.

Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,

Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. All material copyright of Balboa Water Group.

40940_I

18

05-08-12

General Messages

Priming Mode – M019

Each time the spa is powered up, it will enter Priming Mode. The purpose of Priming Mode is to allow the user to run each pump and manually verify that the pumps are primed (air is purged) and water is fl owing. This typically requires observing the output of each pump separately, and is generally not possible in normal operation. Priming Mode lasts 4 minutes, but you can exit it earlier by pressing any Temp button. The heater is not allowed to run during Priming Mode.

NOTE: If your spa has a Circ Pump, it will turn on with Jets 1 in Priming Mode. The Circ Pump will run by itself when Priming Mode is exited. or

READY RANGE READY RANGE

Water Temperature is Unknown

After the pump has been running for 1 minute, the temperature will be displayed.

READY RANGE FLTR1

Too Cold - Freeze Protection

A potential freeze condition has been detected, or the Aux Freeze Switch has closed, and all pumps and blower are activated. All pumps and blower are ON for at least 4 minutes after the potential freeze condition has ended, or when the aux freeze switch opens.

In some cases, pumps may turn on and off and the heater may operate during Freeze Protection.

This is an operational message, not an error indication.

Water is too Hot (OHS) – M029

One of the water temp sensors has detected spa water temp 110°F (43.3°C) and spa functions are disabled. System will auto reset when the spa water temp is below 108°F (42.2°C). Check for extended pump operation or high ambient temp.

Safety Trip - Pump Suction Blockage* – M033

The Safety Trip error message indicates that the vacuum switch has closed. This occurs when there has been a suction problem or a possible entrapment situation avoided. (Note: not all spas have this feature.)

M0XX numbers are Message Codes. See Page 15.

* This message can be reset from the topside panel with any button press.

Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,

Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. All material copyright of Balboa Water Group.

40940_I

19

05-08-12

Heater-Related Messages

Heater Flow is Reduced (HFL) – M016

There may not be enough water fl ow through the heater to carry the heat away from the heating element. Heater start up will begin again after about 1 min. See “Flow Related Checks” below.

Heater Flow is Reduced (LF)* – M017

There is not enough water fl ow through the heater to carry the heat away from the heating element and the heater has been disabled. See “Flow Related Checks” below. After the problem has been resolved, you must press any button to reset and begin heater start up.

Heater may be Dry (dr)* – M028

Possible dry heater, or not enough water in the heater to start it. The spa is shut down for 15 min. Press any button to reset the heater start-up. See “Flow Related Checks” below.

Heater is Dry* – M027

There is not enough water in the heater to start it. The spa is shut down. After the problem has been resolved, you must press any button to reset and restart heater start up. See “Flow Related Checks” below.

Heater is too Hot (OHH)* – M030

One of the water temp sensors has detected 118°f (47.8°C) in the heater and the spa is shut down. You must press any button to reset when water is below 108°f (42.2°C). See “Flow Related Checks” below.

A Reset Message may Appear with other Messages.

Some errors may require power to be removed and restored.

Flow-Related Checks

Check for low water level, suction fl ow restrictions, closed valves, trapped air, too many closed jets and pump prime.

On some systems even when spa is shut down, some equipment may occasionally turn on to continue monitoring temperature or if freeze protection is needed.

* This message can be reset from the topside panel with any button press.

Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,

Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. All material copyright of Balboa Water Group.

40940_I

20

05-08-12

Sensor-Related Messages

READY RANGE FLTR1

Sensor Balance is Poor – M015

The temperature sensors MAY be out of sync by 2°F or 3°F. Call for Service.

Sensor Balance is Poor* – M026

The temperature sensors ARE out of sync. The Sensor Balance is Poor fault has been established for at least 1 hour.

Call for Service.

Sensor Failure – Sensor A: M031, Sensor B: M032

A temperature sensor or sensor circuit has failed. Call for Service.

Miscellaneous Messages

No Communications

The control panel is not receiving communication from the System. Call for Service.

Pre-Production Software

The Control System is operating with test software. Call for Service.

READY RANGE FLTR1

°F or °C is replaced by °T

The Control System is in Test Mode. Call for Service.

* This message can be reset from the topside panel with any button press.

Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,

Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. All material copyright of Balboa Water Group.

40940_I

21

05-08-12

System-Related Messages

Memory Failure - Checksum Error* – M022

At Power-Up, the system has failed the Program Checksum Test. This indicates a problem with the fi rmware (operation program) and requires a service call.

Memory Warning - Persistent Memory Reset* – M021

Appears after any system setup change. Contact your dealer or service organization if this message appears on more than one power-up, or if it appears after the system has been running normally for a period of time.

Memory Failure - Clock Error* – M020 - Not Applicable on the BP1500

Contact your dealer or service organization.

Confi guration Error – Spa will not Start Up

Contact your dealer or service organization.

GFCI Failure - System Could Not Test/Trip the GFCI – M036

NORTH AMERICA ONLY. May indicate an unsafe installation. Contact your dealer or service organization.

A Pump Appears to be Stuck ON – M034

Water may be overheated. POWER DOWN THE SPA. DO NOT ENTER THE WATER. Contact your dealer or service organization.

A Pump Appears to have been Stuck ON when spa was last powered – M035

POWER DOWN THE SPA. DO NOT ENTER THE WATER.

Contact your dealer or service organization.

* This message can be reset from the topside panel with any button press.

Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,

Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. All material copyright of Balboa Water Group.

40940_I

22

05-08-12

Reminder Messages

General maintenance helps.

Reminder Messages can be suppressed by using the PREF Menu. See Page 11.

Reminder Messages can be chosen individually by the Manufacturer. They may be disabled entirely, or there may be a limited number of reminders on a specifi c model.

The frequency of each reminder (i.e. 7 days) can be specifi ed by the Manufacturer.

Press a Temperature button to reset a displayed reminder message.

Alternates with temperature or normal display.

Appears on a regular schedule, e.g. every 7 days.

Check pH with a test kit and adjust pH with the appropriate chemicals.

Alternates with temperature or normal display.

Appears on a regular schedule, e.g. every 7 days.

Check sanitizer level and other water chemistry with a test kit and adjust with the appropriate chemicals.

Alternates with temperature or normal display.

Appears on a regular schedule, e.g. every 30 days.

Clean the fi lter media as instructed by the manufacturer. See HOLD on page 6.

Alternates with temperature or normal display.

Appears on a regular schedule, e.g. every 30 days.

The Ground Fault Circuit Interrupter (GFCI) or Residual Current Device (RCD) is an important safety device and must be tested on a regular basis to verify its reliability.

Every user should be trained to safely test the GFCI or RCD associated with the hot tub installation.

A GFCI or RCD will have a TEST and RESET button on it that allows a user to verify proper function.

Warning:

If freezing conditions exist, a GFCI or RCD should be reset immediately or spa damage could result.

The end user should always trained to test and reset the GFCI or RCD on a regular basis.

Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,

Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. All material copyright of Balboa Water Group.

40940_I

23

05-08-12

Reminder Messages Continued

Alternates with temperature or normal display.

Appears on a regular schedule, e.g. every 90 days.

Change the water in the spa on regular basis to maintain proper chemical balance and sanitary conditions.

Alternates with temperature or normal display.

Appears on a regular schedule, e.g. every 180 days.

Vinyl covers should be cleaned and conditioned for maximum life.

Alternates with temperature or normal display.

Appears on a regular schedule, e.g. every 180 days.

Wood skirting and furniture should be cleaned and conditioned per the manufacturers instructions for maximum life.

Alternates with temperature or normal display.

Appears on a regular schedule, e.g. every 365 days.

Filters should be replaced occasionally to maintain proper spa function and sanitary conditions.

Alternates with temperature or normal display.

As needed.

Install new mineral cartridge

Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,

Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. All material copyright of Balboa Water Group.

40940_I

24

05-08-12

Warning! Qualifi ed Technician Required for Service and Installation

Basic Installation and

Confi guration Guidelines

Use minimum 6AWG copper conductors only.

Torque fi eld connections between 21 and 23 in lbs.

Readily accessible disconnecting means to be provided at time of installation.

Permanently connected.

Connect only to a circuit protected by a Class A Ground Fault Circuit

Interrupter (GFCI) or Residual Current Device (RCD) mounted at least 5’

(1.52M) from the inside walls of the spa/hot tub and in line of sight from the equipment compartment.

CSA enclosure: Type 2

Refer to Wiring Diagram inside the cover of the control enclosure.

Refer to Installation and Safety Instructions provided by the spa manufacturer.

Warning:

People with infectious diseases should not use a spa or hot tub.

Warning:

To avoid injury, exercise care when entering or exiting the spa or hot tub.

Warning:

Do not use a spa or hot tub immediately following strenuous exercise

Warning:

Prolonged immersion in a spa or hot tub may be injurious to your health

Warning:

Maintain water chemistry in accordance with the Manufacturers instructions.

Warning:

The equipment and controls shall be located not less than 1.5 meters horizontally from the spa or hot tub.

Warning! GFCI or RCD Protection.

The Owner should test and reset the GFCI or RCD on a regular basis to verify its function.

Warning! Shock Hazard!

No User Serviceable Parts.

Do not attempt service of this control system. Contact your dealer or service organization for assistance. Follow all owner’s manual power connection instructions. Installation must be performed by a licensed electrician and all grounding connections must be properly installed.

CSA Compliance/Conformité

Caution:

• Test the ground fault circuit interrupter or residual current device before each use of the spa.

• Read the instruction manual.

• Adequate drainage must be provided if the equipment is to be installed in a pit.

• For use only within an enclosure rated CSA Enclosure 3.

• Connect only to a circuit protected by a Class A ground fault circuit interrupter or residual current device.

• To ensure continued protection against shock hazard, use only identical replacement parts when servicing.

• Install a suitably rated suction guard to match the maximum fl ow rate marked.

Warning:

• Water temperature in excess of 38°C may be injurious to your health.

• Disconnect the electrical power before servicing.

Attention:

• Toujours verifi er l’effi cacite du disjoncteur differentiel avant d’utiliser differentiel avant d’utiliser le bain.

• Lire la notice technique.

• Lorsque l’appareillage est installe dans une fosse, on doit assurer un drainage adequat.

• Employer uniquement a l’interieur d’une cloture CSA Enclosure 3.

• Connecter uniquement a un circuit protege par un disjoncteur differentiel de Class A.

• Afi n d’assurer une protection permanente contre le danger de shock electrique, lors de l’entretien employer seulement des pieces de rechange identiques.

• Les prises d’aspiration doivent etre equipees de grilles convenant au debit maximal indique.

Avertissement:

• Des temperatures de l’eau superieures a 38°C peuvent presenter un danger pour la sante.

• Deconnecter du circuit d’alimentation electrique avante l’entretien.

Warning/Advertissement:

• Disconnect the electric power before servicing. Keep access door closed.

• Deconnecter du circuit d’alimentation electrique avant l’entretien.

Garder la porte fermer.

Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,

Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. All material copyright of Balboa Water Group.

40940_I

25

05-08-12

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement