![](http://s3.manualzz.com/store/data/023777258_1-670ebf14bd34af02d47b2c18ec43808e-128x128.png)
advertisement
![Fluke 411D Laser Distance Meter | Manualzz Fluke 411D Laser Distance Meter | Manualzz](http://s3.manualzz.com/store/data/023777258_1-670ebf14bd34af02d47b2c18ec43808e-360x466.png)
Fluke 411D Laser Distance Meter
Technical specifications
Range (for extended distances, use a target plate)
Measuring accuracy
Laser class
Laser type
Automatic power off
Continuous measurement
Addition/subtraction
Battery life
LCD illumination
Data locations
Min/Max
Audible feedback
• Fluke 411D 0.1 m to 30 m (0.33 ft to 100 ft)
• Fluke 416D 0.05 m to 60 m (0.16 ft to 200 ft)
• Fluke 421D 0.05 m to 100 m (0.16 ft to 330 ft)
• Fluke 411D* ± 3 mm (0.118 in)
• Fluke 416D** ± 1.5 mm (± 0.059 in)
• Fluke 421D ± 1.5 mm (± 0.059 in)
• Fluke 411D Class II
• Fluke 416D Class II
• Fluke 421D Class II
• Fluke 411D 635 nm, 1 mW
• Fluke 416D 635 nm, 1 mW
• Fluke 421D 635 nm, 1 mW
• Fluke 411D after 180 seconds
• Fluke 416D after 180 seconds
• Fluke 421D after 180 seconds
• Fluke 411D Yes
• Fluke 416D Yes
• Fluke 421D Yes
• Fluke 411D Yes
• Fluke 416D Yes
• Fluke 421D Yes
• Fluke 411D up to 3,000 measurements
• Fluke 416D up to 5,000 measurements
• Fluke 421D up to 5,000 measurements
• Fluke 411D No
• Fluke 416D Yes
• Fluke 421D Yes
• Fluke 411D No
• Fluke 416D 10
• Fluke 421D 20
• Fluke 411D No
• Fluke 416D Yes
• Fluke 421D Yes
• Fluke 411D No
Pythagoras (Indirect measurement)
Ingress protection
Dimensions
Weight
Temperature range
Operating altitude (ISO
9022)
Storage humidity (at 35 °C)
Batteries
• Fluke 416D Yes
• Fluke 421D Yes
• Fluke 411D Simple
• Fluke 416D Full
• Fluke 421D Full
• Fluke 411D IP40
• Fluke 416D IP54
• Fluke 421D IP54
• Fluke 411D 123 mm x 50 mm x 26 mm (4.84 in x 1.97 in x
1.02 in)
• Fluke 416D 135 mm x 46 mm x 31 mm (5.31 in x 1.81 in x
1.22 in)
• Fluke 421D 127 mm x 52 mm x 29 mm (5.00 in x 2.06 in x 1.13 in)
• Fluke 411D 150 g (5.29 oz)
• Fluke 416D 110 g (3.88 oz)
• Fluke 421D 125 g (4.40 oz)
• Fluke 411D Storage: -25 °C to 70 °C (-13 °F to 158 °F)
• Operation: 0 °C to 40 °C (32 °F to 104 °F)
• Fluke 416D Storage: -25 °C to 70 °C (-13 °F to 158 °F)
• Operation: 0 °C to 40 °C (32 °F to 104 °F)
• Fluke 421D -25 °C to 70 °C (-13 °F to 158 °F)
• 0 °C to 40 °C (32 °F to 104 °F)
• Fluke 411D up to 3500 m
• Fluke 416D up to 3500 m
• Fluke 421D up to 3500 m
• Fluke 411D maximum 85 % for 24 h
• Fluke 416D maximum 85 % for 24 h
• Fluke 421D maximum 85 % for 24 h
• Fluke 411D AAA (2)
• Fluke 416D AAA (2)
• Fluke 421D AAA (2)
• In favorable conditions (optimal target surface, room temperature) up to 10 m (33 ft). In unfavorable conditions, such as intensive sunshine, very weakly reflecting target surface, or large temperature fluctuations, measuring accuracy may deteriorate to approx. ± 0.25 mm/m (±
0.003 in/ft) for distances above 10 m (33 ft).
• In favorable conditions (optimal target surface, room temperature) up to 10 m (33 ft). In unfavorable conditions, such as intensive sunshine, very weakly reflecting target surface, or large temperature fluctuations, the deviation over distances 10 m (33 ft) can increase by approx.
± 0.15 mm/m (± 0.0018 in/ft).
advertisement
Related manuals
advertisement