Imagine Communications AES6800+ B, C, SR, DR, S, D Audio Distribution Amplifier Installation and Operation Manual
Reklama
Reklama
Installation and Operation Manual
AES6800+
AES/EBU Audio Distribution
Amplifiers
Edition C
175-000186-00
Delivering the Moment
Publication Information
© 2014 Imagine Communications Corp. Proprietary and Confidential.
Imagine Communications considers this document and its contents to be proprietary and confidential. Except for making a reasonable number of copies for your own internal use, you may not reproduce this publication, or any part thereof, in any form, by any method, for any purpose, or in any language other than English without the written consent of Imagine Communications. All others uses are illegal.
This publication is designed to assist in the use of the product as it exists on the date of publication of this manual, and may not reflect the product at the current time or an unknown time in the future. This publication does not in any way warrant description accuracy or guarantee the use for the product to which it refers. Imagine Communications reserves the right, without notice to make such changes in equipment, design, specifications, components, or documentation as progress may warrant to improve the performance of the product.
Trademarks
6800+™, ADC™, CCS Navigator™, Channel ONE™, ChannelView™, ClipSync™, Delay™, D Series™, D Series DSX™, Deliver the Moment™, Delivering the Moment™, FAME™, Farad™, G8™, G Scribe™, HView™, IconMaster™, IconLogo™, IconStation™, IconKey™, InfoCaster™, InfoCaster Creator™, InfoCaster Manager™, InfoCaster Player™, InstantOnline™, Invenio®,
Live Update™, mCAPTURE™, Magellan™, Magellan CCS Navigator™, Magellan Q SEE™, MultiService SDN™, NetPlus™,
NetVX™, NewsForce™, Nexio® G8™, Nexio AMP® ChannelView™, Nexio® Channel ONE™, Nexio® ClipSync™, Nexio®
Delay™, Nexio® Digital Turnaround Processor™, Nexio® Farad™, Nexio® G Scribe™, Nexio® IconKey™, Nexio® IconLogo™,
Nexio® IconMaster™, Nexio® IconStation™, Nexio® InfoCaster™, Nexio® InfoCaster Creator™, Nexio® InfoCaster Manager™, Nexio® InfoCaster Player™, Nexio® InfoCaster Traffic™, Nexio® InstantOnline™, Nexio® mCAPTURE™, Nexio® News-
Force™, Nexio® NXIQ™, Nexio® Playlist™, Nexio® Remote™, Nexio®RTX Net™, Nexio® TitleMotion™, Nexio® TitleOne™,
Nexio® Velocity ESX™, Nexio® Velocity PRX™, Nexio® Velocity XNG™, Nexio® Volt™, OPTO+™, Panacea™, Platinum™,
Playlist™, Predator II GRF™, Predator II GX™, Punctuate™, Remote™, RTX Net™, QuiC™, Q SEE™, SD STAR™, Selenio™,
Selenio 6800+™, SelenioNext™, Selenio X50™, Selenio X85™, Selenio X100™, TitleMotion™, TitleOne™, Velocity ESX™,
Velocity PRX™, Velocity XNG™, Versio™, Videotek® SD STAR™, X50™, and X85™ are trademarks of Imagine Communications or its subsidiaries.
Altitude Express®, Connectus®, Enabling PersonalizedTV®, ICE® Broadcast System, ICE Illustrate®, ICE Q® algorithms, ICE-
PAC®, Imagine ICE®, Inscriber®, Inscriber® Connectus®, Invenio®, NEO®, Nexio®, Nexio AMP®, PersonalizedTV®, Router-
Works®, Videotek®, Videotek® ASI STAR®, Videotek® GEN STAR®, and Videotek® HD STAR® are registered trademarks of
Imagine Communications or its subsidiaries.
Microsoft® and Windows® are registered trademarks of Microsoft Corporation. HD BNC is a trademark of Amphenol
Corporation. Some products are manufactured under license from Dolby Laboratories. Dolby and the double D symbol are registered trademarks of Dolby Laboratories. DTS Neural audio products are manufactured under license from DTS
Licensing Limited. DTS and the Symbol are registered trademarks & the DTS Logos are trademarks of DTS, Inc. © 2008
2010 DTS, Inc. All other trademarks and trade names are the property of their respective companies.
Contact Information
Imagine Communications has office locations around the world. For locations and contact information see:
http://www.imaginecommunications.com/contact us/
Support Contact Information
For support contact information see:
▪
▪ Support Contacts: http://www.imaginecommunications.com/services/technical support/ eCustomer Portal: http://support.imaginecommunications.com
© 2014 Imagine Communications Corp. Proprietary and Confidential
AES6800+
AES/EBU Audio Distribution
Amplifier
Installation and Operation Manual
Edition C
November 2011
Contents
Preface
........................................................................................................................ vii
Waste from Electrical and Electronic Equipment (WEEE) Directive ............................... ix
Chapter 1 Introduction
.............................................................................................................. 1
Chapter 2 Installation and Configuration
....................................................................... 7
+ Frame Power Ratings ..................................................................... 11
Copyright © 2003-2011, Harris Corporation v
vi
Contents
+ Modules ............................................................................................12
+ Modules ...................................................................................12
+ Modules .................................................................................12
Chapter 3 Operation
.................................................................................................................. 13
Chapter 4 Specifications
......................................................................................................... 19
Appendix A Troubleshooting
Index
........................................................................................................................... 27
Copyright © 2003-2011, Harris Corporation
Preface
Manual Information
Purpose
This manual details the features, installation procedures, operational procedures, and specifications of the AES6800
+ AES/EBU audio distribution amplifier.
Audience
This manual is written for engineers, technicians, and operators responsible for the installation, setup, and/or operation of the AES6800
+ AES/EBU audio distribution amplifier.
Revision
History
Table P-1 PManual Revision History
Edition
A
B
Date
November 2003
July 2005
C November 2011
Revision History
Initial release
Added information concerning maximum 6800
+ frame power ratings
Added index
Minor corrections and updates to contents
Writing
Conventions
To enhance your understanding, the authors of this manual have adhered to the following text conventions:
Table P-2 Manual Style and Writing Conventions
Term or Convention
Bold
Italics
CAPS
Code
Description
Indicates dialog boxes, property sheets, fields, buttons, check boxes, list boxes, combo boxes, menus, submenus, windows, lists, and selection names.
Indicates email addresses, the names of books or publications, and the first instances of new terms and specialized words that need emphasis.
Indicates a specific key on the keyboard, such as ENTER,
TAB, CTRL, ALT, or DELETE.
Indicates variables or command-line entries, such as a
DOS entry or something you type into a field.
Copyright © 2003-2011, Harris Corporation vii
viii
Preface
Table P-2 Manual Style and Writing Conventions (Continued)
Term or Convention
> hyperlink
Internet address
Description
Indicates the direction of navigation through a hierarchy of menus and windows.
Indicates a jump to another location within the electronic document or elsewhere
Indicates a jump to a website or URL
Indicates important information that helps to avoid and troubleshoot problems.
Note:
Obtaining
Documents
Product support documents can be viewed or downloaded from our website. Alternatively, contact your Customer Service representative to request a document.
Unpacking/Shipping Information
This product was carefully inspected, tested, and calibrated before shipment to ensure years of stable and trouble-free service.
1
Check equipment for any visible damage that may have occurred during transit.
2
Confirm that you have received all items listed on the packing list.
3
Contact your dealer if any item on the packing list is missing.
4
Contact the carrier if any item is damaged.
5
Remove all packaging material from the product and its associated components before you install the unit.
Keep at least one set of original packaging, in the event that you need to return a product for servicing.
In the unlikely event that your product fails to operate properly, please contact Customer
Service to obtain a Return Authorization (RA) number, then send the unit back for servicing.
Keep at least one set of original packaging in the event that a product needs to be returned for service. If the original package is not available, you can supply your own packaging as long as it meets the following criteria:
The packaging must be able to withstand the product’s weight.
The product must be held rigid within the packaging.
There must be at least 2 in. (5 cm) of space between the product and the container.
The corners of the product must be protected.
Ship products back to us for servicing prepaid and, if possible, in the original packaging material. If the product is still within the warranty period, we will return the product prepaid after servicing.
Copyright © 2003-2011, Harris Corporation
AES6800
+
Installation and Operation Manual
ix
Safety Standards and Compliances
A 6800
+ series safety manual is shipped with every 6800+ Frame Installation and
Operation Manual and can be downloaded from our website. Alternatively, contact your
Customer Service representative for a copy of this safety manual.
Restriction on Hazardous Substances (RoHS) Directive
Directive 2002/95/EC—commonly known as the European Union (EU) Restriction on
Hazardous Substances (RoHS)—sets limits on the use of certain substances found in electrical and electronic equipment. The intent of this legislation is to reduce the amount of hazardous chemicals that may leach out of landfill sites or otherwise contaminate the environment during end-of-life recycling. The Directive takes effect on July 1, 2006, and it refers to the following hazardous substances:
Lead (Pb)
Mercury (Hg)
Cadmium (Cd)
Hexavalent Chromium (Cr-V1)
Polybrominated Biphenyls (PBB)
Polybrominated Diphenyl Ethers (PBDE)
In accordance with this EU Directive, all products sold in the European Union will be fully
RoHS-compliant and “lead-free.” (See our website for more information on dates and deadlines for compliance.) Spare parts supplied for the repair and upgrade of equipment sold before July 1, 2006 are exempt from the legislation. Equipment that complies with the
EU directive will be marked with a RoHS-compliant symbol, as shown in
.
Figure P-1 RoHS Compliance Symbol
Waste from Electrical and Electronic Equipment (WEEE) Directive
The European Union (EU) Directive 2002/96/EC on Waste from Electrical and Electronic
Equipment (WEEE) deals with the collection, treatment, recovery, and recycling of electrical and electronic waste products. The objective of the WEEE Directive is to assign the responsibility for the disposal of associated hazardous waste to either the producers or users of these products. Effective August 13, 2005, producers or users will be required to recycle electrical and electronic equipment at end of its useful life, and must not dispose of the equipment in landfills or by using other unapproved methods. (Some EU member states may have different deadlines.)
In accordance with this EU Directive, companies selling electric or electronic devices in the
EU will affix labels indicating that such products must properly recycled. (See our website for more information on dates and deadlines for compliance.) Contact your local Sales representative for information on returning these products for recycling. Eequipment that complies with the EU directive will be marked with a WEEE-compliant symbol, as shown in
.
Copyright © 2003-2011, Harris Corporation
x
Preface
Figure P-2 WEEE Compliance Symbol
Safety Terms and Symbols
This product manual uses the following safety terms and symbols to identify certain conditions or practices. See the 6800
+ Safety Instructions and Standards Manual for more information.
Table P-3 Safety Terms and Symbols
WARNING
Identifies conditions or practices that can result in personal injury or loss of life—high voltage is present. Uninsulated dangerous voltage within the product’s enclosure may be sufficient to constitute a risk of electric shock to persons.
CAUTION
Identifies conditions or practices that can result in damage to the equipment or other property. Important operating and maintenance (servicing) instructions are included in the literature accompanying the product.
Copyright © 2003-2011, Harris Corporation
1
Introduction
Product Description
AES6800
+ is a digital audio distribution amplifier module set in the new 6800+ family. The
AES6800
+ features cable auto-equalization, data reclocking, and incoming data error detection and reporting. The error detection and reporting features use front-mounted LEDs and an external alarm reporting. Housed in an FR-6802
+ series frame, this distribution amplifier meets the AES interface standards according to SMPTE 276M, AES3 1992 (r 1997), and AES3 id-2001.
These DAs feature high audio performance, low cost, remote monitoring, and diagnostic capability in our control system.
You can set up and monitor the AES6800
+ locally via DIP switches. You can monitor error signals and card status remotely on a PC. For remote monitoring, you can use either a serial
RS-232 or optional ICE6800
+ Ethernet connection.
Typical Broadcast and Production Applications
The AES6800
+ distribution amplifier can be used in broadcast, cable, production, educational, and auditorium applications where a low cost method of distributing AES/EBU digital audio signals is required.
Main
Features
Available in balanced (AES6800
+B) and coaxial (AES6800+C) I/O formats
Distribution of one signal input into four or nine isolated outputs
Input signal lock detect
Automatic or manual EQ
Sampling frequency from 30 kHz to 192 kHz
Bypass mode for non-AES signals of < 30 MHz @ 50% duty cycle
Automatic reporting of data or signal quality errors, such as
CRC errors
Validity
Confidence
Biphase encoding errors
Parity errors
Copyright © 2003-2011, Harris Corporation
1
2
Chapter 1
Introduction
Module Descriptions
Front Module AES6800
+B
The AES6800
+B is a balanced 4- or 9-output AES/EBU digital audio distribution amplifier. It uses serial transmission format over twisted pair for two-channel linearly represented digital audio data per AES3-1992.
is a generic top-front view of a typical AES6800
+B front module, and shows the general location of LEDs and jumpers.
Figure 1-1 Typical AES6800
+B Front Module
AES6800
+C
The AES6800
+C is a coaxial 4- or 9-output AES/EBU digital audio distribution amplifier. It uses serial transmission format over 75
coaxial cable per SMPTE 276M.
is a generic top-front view of a typical AES6800
+C front module, and shows the general location of LEDs and jumpers.
Figure 1-2 Typical AES6800
+C Front Module
Copyright © 2003-2011, Harris Corporation
AES6800
+
Installation and Operation Manual
3
LEDs, Switches, and Jumpers
briefly describes generic 6800
+ LEDs, switches, and jumpers. See
Installation and Configuration
for more information on specific AES6800
+ module controls, LEDs, and jumpers.
Table 1-1 Generic 6800
+ Module Features
Feature Description
Module status
LEDs
Control LEDs
Monitoring
LEDs
Local/remote control jumper
Various color and lighting combinations of these
LEDs indicate the module state. See
information.
Various lighting combinations of these control LEDs
(sometimes referred to as “Bank Select LEDs”) indicate the currently selected bank. (This item not available on the AES6800
+)
Each 6800
+ module has a number of LEDs assigned to indicate varying states/functions. See
on page 16 for a description of these LEDs.
Local: Locks out external control panels and allows card-edge control only; limits the functionality of remote software applications to monitoring
Remote: Allows remote or local (card-edge) configuration, operation, and monitoring of the
AES6800
+
Each 6800
+ module has a number of LEDs assigned to indicated varying states/functions.
These functions are listed in
.
Table 1-2 AES6800
+ Module-Specific Status LEDs
Condition Color Function
Green No error, everything working well All OK
No Errors
No lock
Biphase coding error
Red
Amber
Signal not present or cannot be locked
Biphase coding of incoming data incorrect
Parity error
CRC error
Amber
Amber
Confidence flag error
Validity error
Alarm
Amber
Amber
Amber
AES stream’s parity not set as specified
CRC value calculated for incoming data does not match the CRC byte of channel status word
Received data eye opening less than half a bit period, indicating a possible lack of signal strength or high jitter; also may mean that insufficient EQ applied
AES stream’s validity bit is high (incoming data not suitable for conversion to an analog audio signal)
External alarm contact closure asserted; card reporting an alarm
Copyright © 2003-2011, Harris Corporation
4
Chapter 1
Introduction
Table 1-2 AES6800
+ Module-Specific Status LEDs
Condition Color Function
Frame status*
Red
Green
Frame alarm
All OK, no frame alarm
* If the frame status LED is not lit, the module may not be operational.
Back Module FR6802
+ Frame Back Module
shows the single-width back connector and
shows the double-slot back connector used by the AES6800
+ when installed in an FR6802+ or FR6802+DM frame.
AES IN
AES IN
AES OUT 1
AES OUT 1
AES OUT 2
AES OUT 3
AES OUT 2
AES OUT 3
AES OUT 4
AES OUT 4
Balanced Unbalanced
Figure 1-3 Single-Width Back Connectors for FR6802
+ Frame
AES IN AES OUT 9
AES OUT 9 AES IN
AES OUT 8 AES OUT 1 AES OUT 1 AES OUT 8
AES OUT 2 AES OUT 7
AES OUT 3 AES OUT 6
AES OUT 7 AES OUT 2
AES OUT 6 AES OUT 3
AES OUT 4 AES OUT 5
AES OUT 5 AES OUT 4
Balanced Unbalanced
Figure 1-4 Double-Slot Back Connectors for FR6802
+ and FR6802+DM Frames
Copyright © 2003-2011, Harris Corporation
AES6800
+
Installation and Operation Manual
5
6800/7000 Series Frame Back Module (Overlay) (AES6800
+C
Only)
Note: Remote monitoring for the AES6800
+C module is not available if it is installed in a
6800/7000 series frame.
shows the double-slot back connector overlay used by the AES6800
+C when installed in a 6800/7000 series frame. The AES6800
+B cannot be installed in a 6800/7000 series frame.
AES IN
AES OUT 2 AES OUT 1
AES OUT 4 AES OUT 3
AES OUT 6 AES OUT 5
AES OUT 8 AES OUT 7
Figure 1-5 Back Connector for 6800/7000 Series Frame
Signal Flow
AES IN Equalizer Reclocker
+BD, +CD only
Figure 1-6 AES6800
+B and AES6800+C Signal Flow Diagram
CPU Monitoring and Control
AES OUT 1
AES OUT 2
AES OUT 3
AES OUT 4
AES OUT 5
AES OUT 6
AES OUT 7
AES OUT 8
AES OUT 9
Copyright © 2003-2011, Harris Corporation
6
Chapter 1
Introduction
Copyright © 2003-2011, Harris Corporation
2
Installation and Configuration
7
Overview
CAUTION: Before installing this product, read the 6800
+ Series Safety Instructions
and Standards manual shipped with every FR6802
+ Frame Installation and
Operation Manual, or downloadable from our website. This safety manual contains important information about the safe installation and operation of 6800
+ series products.
See the FR6802
+ Frame Installation and Operation Manual for information about installing and operating an FR6802
+ frame and its components.
The AES6800
+C can be installed in a 6800/7000 series frame. When installed in a 6800/
7000 series frame, the AES6800
+C will not report to the frame alarm.
The AES6800
+B cannot be installed in a 6800/7000 series frame.
Unpacking the Module
Preparing the Product for Installation
Before you install the AES6800
+, perform the following:
Note: Contact your Customer Service representative if parts are missing or damaged.
Check the equipment for any visible damage that may have occurred during transit.
Confirm receipt of all items on the packing list. See
for more information.
Remove the anti-static shipping pouch, if present, and all other packaging material.
Retain the original packaging materials for possible re-use.
Unpacking/Shipping Information
on page viii for information about returning a
product for servicing.
Copyright © 2003-2011, Harris Corporation
8
Chapter 2
Installation and Configuration
Checking the
Packing List
Table 2-1 AES6800
+ Packing List
Ordered Product
AES6800
AES6800
AES6800
AES6800
+
+S
+D
+SR
AES6800
+DR
Content Description
One AES6800
+ front module
One AES6800
+ Installation and Operation Manual
One AES6800
+ front module
One standard single-slot back connector
One AES6800
+ Installation and Operation Manual
One AES6800
+ front module
One standard double-slot back connector
One AES6800
+ Installation and Operation Manual
One standard single-slot back connector
One standard double-slot back connector
Setting Jumpers
Note: We recommend that you use the available 6800
+ software control options (serial/
local or Ethernet/remote) to aid in viewing, setting, and confirming parameter values.
The AES6800
+ module has two standard jumpers, which are located on the front card edge. The jumpers allow you to switch between EQ automatic and manual modes, and between AES and bypass modes.
Figure 2-1 Settings for Automatic / Manual EQ Mode, and AES / Bypass Mode
EQ Mode
This distribution amplifier provides two options for EQ adjustment: manual and automatic.
The mode is jumper-selected. See
.
Copyright © 2003-2011, Harris Corporation
AES6800
+
Installation and Operation Manual
9
Manual EQ
In manual adjust mode a card-edge mounted, multi-turn potentiometer manual EQ adjust is used for adjusting equalization. The Lock and Confidence flag warnings on the card-edge mounted LED indicator can be used to determine the amount of EQ required without external test equipment. If the confidence flag error light is on, more EQ is needed. To increase the amount of EQ, use a screwdriver to turn the manual EQ adjustment potentiometer counter-clockwise until the Confidence LED indicator turns off and the Lock
LED indicator turns green.
Automatic EQ
Note: The factory default configurations for J1 is in the “AUTO” position.
In automatic adjust mode, the AES6800
+ automatically sets the amount of cable EQ needed to improve signal quality in case of signal degradation over extended cable lengths.
The EQ is designed for use with up to 2,000 ft (609 m) of Belden 8281 coaxial cable or equivalent, or up to 1,000 ft (304 m) of Belden 8451 twisted pair cable or equivalent.
AES or
Bypass Mode
AES Mode
Note: The factory default configuration is for AES mode.
AES mode is used to allow the distribution amplifier to automatically receive and decode audio data according to AES3 interface standards. It also allows the DA to decode the AES data stream for any error information.
Bypass Mode
Bypass mode is used to allow the distribution amplifier to pass non-AES or non-biphase encoded signals of frequency less than 30 MHz at 50% duty cycle.
Setting the Jumper for the AES Digital Audio Signal
Follow this procedure to set the jumper for the proper AES digital audio signal:
1
Locate the jumper set on the module (near the top front of the module).
shows the standard location of the jumper set.
Copyright © 2003-2011, Harris Corporation
10
Chapter 2
Installation and Configuration
Figure 2-2 Location of the Jumper Set
2
Place a jumper on the pin that corresponds to the mode that you want (see Figure 2-1 on page 8).
Setting DIP Switches
Note: DIP switches are set at the Manufacturing facility to the ALL ON position.
A six-pin DIP switch provides for external frame alarm configuration. The DIP switches allow you to select which errors contained within the biphase encoded data stream (received by the receiver) can trigger a frame alarm. When a DIP switch is in the ON position, any error received from the AES biphase encoded signal will trigger the frame alarm, light the appropriate LED, and light the red frame status LED.
DIP switches must be set to the ON position for the alarms to show up in Navigator.
The DIP switches allow selectable error reporting of these types of errors:
CRC errors
Loss of lock
Validity errors
Confidence errors
Biphase coding errors
Parity errors
To prevent any of the listed errors from triggering the frame alarm, you must set the appropriately labeled DIP switch to the OFF position.
Copyright © 2003-2011, Harris Corporation
AES6800
+
Installation and Operation Manual
11
Figure 2-3 Location of DIP Switches
Maximum 6800
+ Frame Power Ratings
describes the maximum allowable power ratings for 6800
+ frames.Note the given maximums before installing any 6800
+ modules in your frame.
AES6800
+B and AES6800+C modules can be installed in either FR6802+ frames;
AES6800
+C modules only can be installed in 6000/7000 series frames.
Table 2-2 Maximum Power Ratings for 6800
+ Frames
6800
+ Frame Type
Max. Frame
Power
Dissipation
50 W
Number of
Usable Slots
10
Max. Power
Dissipation
Per Slot
5 W FR6802
+DM frame
(with AC power supply, without fans)
FR6802
+DMF frame
(with AC power supply and fans)
FR6802
+X frame
(with AC power supply, without fans)
FR6802
+XF frame
(with AC power supply and fans)
FR6802
+DM48frame
(With DC power supply, without fans)
FR6802
+DMF48 frame
(With DC power supply and fans)
FR6802
+X48 frame
(With DC power supply, without fans)
FR6802
+XF48 frame
(With DC power supply and fans)
FR6802
+QXF frame
(with AC or DC power supply)
FR6822
+ frame
(with AC or DC power supply)
120 W
50 W
120 W
50 W
105 W
50 W
105 W
120W
120W
10
20
20
10
10
20
20
20
20
12 W
2.5 W
6 W
5.0 W
10.5 W
2.5 W
5.25 W
6 W
6 W
Copyright © 2003-2011, Harris Corporation
12
Chapter 2
Installation and Configuration
Installing 6800
+ Modules
Required Frames and Back Connector Types
The AES6800
+ modules have double-width back connectors that can be installed in an
FR6802
+X(F) or a 6000/7000 series frame. See the FR6802+ Frame Installation and
Operation Manual for details on installing back connectors in an FR6802
+ frame.
See the 6800 Series Frames and Power Supply Installation and Operation Manual for details on installing back connectors in a 6000/7000 series frame.
Installing AES6800
+ Modules
These modules require no specialized installation procedures.
See the FR6802
+ Frame Installation and Operation Manual for information about installing and operating an FR6802
+ frame and its components.
See the 6800 Series Frames and Power Supply Installation and Operation Manual for information about installing and operating a 6800/7000 series frame.
Removing AES6800
+ Modules
These modules require no specialized removal procedures.
See the FR6802
+ Frame Installation and Operation Manual for information about removing components in an FR6802
+ frame.
See the 6800 Series Frames and Power Supply Installation and Operation Manual for information about removing components in a 6800/7000 series frame.
Making Connections
Once you have installed your AES6800
+ modules, you can connect them to the appropriate input and outputs.
Copyright © 2003-2011, Harris Corporation
3
Operation
Overview
Controls for AES6800
on page 10), in addition to parameters that can be monitored in
CCS Navigator or using a NUCLEUS control panel.
This chapter describes how to operate the AES6800
+ using local controls only. See the
CCS™ Navigator™ or NUCLEUS user manuals for information on how to operate this product remotely.
Introducing Parameter Types
Most AES6800
+ parameters are adjustable, and can be set using either card-edge controls
(see
on page 8) or a software application. However, there are some
parameters that are considered “read-only” and cannot be changed. Indicated by the abbreviation “[RO],” these parameters provide status and feedback information only.
Adjustable Parameters
Two types of adjustable parameters can be changed using the card-edge controls:
Numerical parameters—which require you to select a value within a numerical range
Selectable parameters—which require you to select a specific option
Both numerical and selectable parameter changes are immediate.
Use the available 6800
+ software controls (serial/local or Ethernet/remote network) to view and monitor parameter selections.
Read-Only Parameters
Many of the read-only parameters are also represented by LEDs on the front of the module’s
for the location of these LEDs.
Copyright © 2003-2011, Harris Corporation
13
14
Chapter 3
Operation
Figure 3-1 Location of LEDs
Operating Notes
When setting the control parameters on the AES6800
+, observe the following:
When you change a parameter, the effect is immediate. However, the module requires up to 20 seconds to save the latest change. After 20 seconds, the new settings are saved and will be restored if the module loses power and must be restarted.
When setting the control parameters on the AES6800
+, observe the following:
When the module is set to remote control, the reclocking mode is controlled by the
CCS control software application. When the module powers up with remote selected, the reclocking mode is set to the last known value.
When the module is set to local control, the reclocking mode is controlled by adjusting the card-edge jumper to the appropriate setting. Reclocking mode selections are reflected in the CCS control software application. Any remote attempts to adjust the reclocking mode will have no effect.
If a card-edge jumper is not installed the reclocking mode is set to Auto.
Copyright © 2003-2011, Harris Corporation
AES6800
+
Installation and Operation Manual
15
Setting Locally Accessible Parameters
+ parameters that are accessible locally via an on-board
on page 8 for more information about setting these
parameters via jumper.
Table 3-1 Locally Accessible Parameters
Parameter
Name
Module status
Range Description
All OK
CRC
Validity
Biphase coding
Parity
Confidence
No Lock
Red
Green
Off
Red, blinking
Alternating
Green
Yellow
Off
Yellow
Off
Yellow
Off
Yellow
Off
Yellow
Off
Red
Alarm condition exists
Operating properly
Not operational
Not operational; hardware fault
Module configuration ongoing
Signal present, no errors
CRC value of the data does not match the CRC byte of the channel status
CRC value correct
Incoming value not suitable for conversion to analog audio signal
Data valid
Biphase coding of incoming data invalid
Biphase coding correct
AES stream parity bit is not set as specified
AES stream parity bit correct
Received data pattern is less than one-half a bit period, indicating a possible leak in signal strength, high jitter, or insufficient EQ
Received data pattern correct
Signal is not present
Changing Parameter Settings
You can trigger the master frame alarm from the AES error detection and reporting feature designed into the AES6800
+ distribution amplifier. The error detection feature will report problems contained within the AES data stream, such as CRC, validity, confidence, biphase, parity, and lock.
To “force” the frame alarm on an AES error detection, you must set the corresponding DIP switch (S1) to the “ON” position. DIP switches are marked accordingly.
Copyright © 2003-2011, Harris Corporation
16
Chapter 3
Operation
Recalling Default Parameter Settings
You cannot recall default parameter settings for the AES6800
+.
Reading the Software Version
The current software version of your AES6800
+ module can only be viewed using Navigator
(via Ethernet control). See your CCS Navigator User Manual or Online Help for information on viewing software versions.
Reading the Hardware Version
The current hardware revision of your AES6800
+ module can only be viewed using
Navigator (via Ethernet control). See your CCS Navigator User Manual or Online Help for information on viewing hardware identifiers.
LEDs and Alarms
Module
Status LED
The AES6800
+ module has a module status LED that reports the state of the module. See
on page 2 for the location of this LED, and
for a definition of LED colors.
Table 3-2 Status LED Descriptions
LED Color
Sequence
Off
Meaning
Green
Red
There is no power to the module; the module is not operational
There is power to the module; the module operates properly
There is an alarm condition
Alarms
Alarms are usually logged and monitored within CCS Navigator. See the Navigator user manual or online help for more information.
Note: For alarms to appear in CCS Navigator, the DIP switches on the module must be set
Copyright © 2003-2011, Harris Corporation
AES6800
+
Installation and Operation Manual
17
Other LED
Descriptions
on page 2 for the location of this LED , and
for a definition of LED colors and meanings.
Table 3-3 LED Descriptions
LED Name
No Lock
CRC
Validity
Confidence
Biphase
Parity
All OK
Color
Red
Amber
Amber
Amber
Amber
Amber
Green
Description (When Lit)
Loss of signal lock
CRC error
Validity error
Confidence error
Biphase error
Parity error
AES data stream good
Copyright © 2003-2011, Harris Corporation
18
Chapter 3
Operation
Copyright © 2003-2011, Harris Corporation
4
Specifications
Specifications and designs are subject to change without notice.
Inputs
1
Table 4-1 AES6800
+B
1
Input Specifications
Item
Number of inputs
Specification
1
Input connector
Signal type
AES frame rates
Impedance
Signal amplitude
Cable EQ
WECO
Balanced, transformer coupled
30 kHz – 192 kHz
110
0.2 Vp-p to 7 Vp-p
0 – 984 ft (0 – 300 m) twisted pair Belden
8451 or equivalent
Table 4-2 AES6800
+C
1
Input Specifications
Item
Number of inputs
Specification
1
Input connector
Signal type
AES frame rates
Impedance
BNC
AC coupled
30 kHz – 192 kHz
75
Signal amplitude
Return loss
Cable EQ
0.1 Vp-p to 2 Vp-p
> 30 dB
0 – 1969 ft (0 – 600 m) coaxial Belden 8281 or equivalent
1
AES6800
+B conforms to AES3-1992. AES6800+C conforms to SMPTE 276M.
Copyright © 2003-2011, Harris Corporation
19
20
Chapter 4
Specifications
Outputs
1
Table 4-3 AES6800
+B 1
Output Specifications
Item
Number of outputs
Specification
4 or 9
Output connector
Type
Impedance
Signal amplitude
WECO
Balanced, transformer coupled
110
5 Vp-p
1 V into 110 load
Table 4-4 AES6800
+C 1
Output Specifications
Item
Number of outputs
Specification
4 or 9
Output connector
Signal type
Impedance
Return loss
Signal amplitude
BNC
Uncoupled
75
> 30 dB
1.0 Vp-p
10% into 75 load
Performance
2
Table 4-5 AES6800
+B
1
Performance Specifications
Item
Jitter
DC offset
Rise/fall time
Specification
< 5 ns
0.0 V
50 V
5 ns to 30 ns
Table 4-6 AES6800
+C
1
Performance Specifications
Item
Jitter
DC offset
Rise/fall time
Specification
< 5 ns
0.0 V
0.05 V
30 ns to 44 ns
1
AES6800
+B conforms to AES3-1992. AES6800+C conforms to SMPTE 276M.
2
AES6800
+B conforms to AES3-1992. AES6800+C conforms to SMPTE 276M.
Copyright © 2003-2011, Harris Corporation
Power Consumption
Table 4-7 Power Consumption Specifications
Item
AES6800
+B
AES6800
+C
Specification
< 5 W
< 5 W
Propagation Delay
Table 4-8 Propagation Delay Specifications
Item
AES6800
+B
AES6800
+C
Specification
< 600 ns @ 48 kHz
< 600 ns @ 48 kHz
Temperature
Table 4-9 Temperature Specification
Item
Performance
Operating
Specification
41° – 104°F (5° – 40°C)
32° – 122°F (0° – 50°C)
AES6800
+
Installation and Operation Manual
21
Copyright © 2003-2011, Harris Corporation
22
Chapter 4
Specifications
Copyright © 2003-2011, Harris Corporation
A
Troubleshooting
Software Communication Problems
The frame is powered up, but the module does not communicate with
CCS Navigator.
Solutions
Ensure you have specified the proper module slot.
See the installation and operation manual for your frame for more information about slot identification.
Verify whether there is an ICE6800
+ or 6800+ETH module installed in the frame.
Remove any legacy 6800 series product that is in the frame.
CCS software cannot communicate with legacy 6800 series products, even though these modules may operate with card-edge controls in an FR6802
+ frame. Legacy 6800 products do not have the “
+” symbol on their extractor handles.
Check for bent pins on the back module by following this procedure:
i.
Unplug the front module.
ii.
Unscrew and remove the back module.
iii. Inspect the 20- or 30-pin spring connector at the bottom of the back module
(
on page 24), and verify that the connector does not have any
slightly bent or pressed pins.
iv. Carefully reposition any bent pins; If this is not possible, contact Customer Support.
23
Copyright © 2003-2011, Harris Corporation
24
Appendix A
Troubleshooting
Figure A-1 Typical Back Module Spring Connector
CCS software sees the frame, but does not find all of the modules.
Solutions
Remove any legacy 6800 series products.
Plug your modules in before starting the discovery.
Start your discovery after the frame and all modules have fully powered up.
it.
CCS software shows a module in the Control window, but cannot control
Solution
1
Set the module’s Local/Remote jumper to Remote.
2
Ensure the module name in the Control window matches the module type in the frame.
3
Gently push the module into its slot in the frame to ensure it is seated properly and powered up.
4
Verify that the Control window indicates the device is ready.
Hardware Communication Problems
After a power failure, the frames and PC do not communicate.
Solution
1
Wait four minutes for the frames to recover from the power failure.
2
Close the CCS software, and then restart the PC.
3
Restart the software application.
Copyright © 2003-2011, Harris Corporation
AES6800
+
Installation and Operation Manual
25
The module does not seem to work.
Solutions
Ensure the correct frame is powered up.
Verify that all appropriate rear connections are secure.
Gently push the module into its slot in the frame to ensure it is seated properly.
Ensure the back module does not have bent pins by following this procedure:
i.
Unplug the front module.
ii.
Unscrew and remove the back module.
iii. Inspect the spring connector at the bottom of the back module (
), and verify the connector does not have any slightly bent or pressed pins.
iv. Carefully reposition any bent pins; if this is not possible, contact Customer Service.
Copyright © 2003-2011, Harris Corporation
26
Appendix A
Troubleshooting
Copyright © 2003-2011, Harris Corporation
Index
A
Adjustable parameters
AES digital audio signal
mode
Alarms
configuring DIP switches for
Applications
B
Back modules
Bypass mode
D-E
Descriptions modules back module
–
front module
–
product
DIP switches
Discovery failure
EQ mode
automatic EQ
manual EQ
F-G
Features
Front modules
–
I
Input specifications
Installation and configuration back connector types, required
DIP switches
installing modules
jumpers
AES mode
bypass mode
control types
EQ mode
–
setting jumpers
packing list
power ratings
preparing module for installation
removing modules
required frames
unpacking modules
Introduction applications
descriptions modules
product
features
signal flow diagram
J-K
Jumpers
AES mode
bypass mode
control types
EQ mode
setting jumpers
L
LEDs
M-N
Manual revision history
writing conventions
Modules alarms
back modules
front modules
–
installing modules
LEDs
removing modules
Navigator configuring alarms to appear in
O
Operating temperature
Copyright © 2003-2011, Harris Corporation
27
28
Index
Operation operating notes
parameter types
recalling parameter settings
Output specifications
P-Q
Packing list
Parameters adjustable
parameter types
read-only
recalling settings
Performance specifications
Performance temperature
Power consumption specifications
Power ratings
Preparing for installation
Product desccription
Propagation delay specifications
R
Read-only parameters
Removing modules
S
Safety compliances
standards
symbols
terms
Setting
AES digital audio signal
DIP switches
jumpers
–
Shipping information
Signal flow
AES6800
+B
Specifications input
output
performance
power consumption
propagation delay
temperature
T
Temperature specifications
Troubleshooting
discovery failure
installation
local control
not ready status
power failure causes communication problems
remote control
U
Unpacking information
Copyright © 2003-2011, Harris Corporation
Stáhnout
Reklama