Addonics ST4ESA-B disk array User guide


Add to my manuals
8 Pages

advertisement

Addonics ST4ESA-B disk array User guide | Manualzz

T E C H N O L O G I E S

User Guide

Mini Storage Tower

(MST5HMXA)

www.addonics.com

v5.1.11

Technical Support

If you need any assistance to get your unit functioning properly, please have your product information ready and contact Addonics Technical Support at:

Hours: 8:30 am - 6:00 pm PST

Phone: 408-453-6212

Email: http://www.addonics.com/support/query/

Note: You need to verify that the eSATA port you are connecting the tower is port multiplier compatible. If it is connected to a non-port multiplier compatible host controller, the operating system will only see one drive out of the five connected and that is the drive connected to port 1.

For example, when the tower is connected to a SATA Host controller with SiI3124 or SiI3132 chip which is port multiplier compatible, in the RAID BIOS of the host controller, you will only see one drive and that is the drive connected to port 1 on the hardware PM.

All the SATA drives connected to the tower will show in the SATARAID5 Array

Manager of the SATA Host controller with SiI3124 or SiI3132 chip.

Removing Cover of Mini

Storage Tower

Loosen the 3 screws at the back of the tower using a Philips screwdriver by turning counter-clockwise. Separate the metal casing of the tower from the housing by lifting up the casing as shown on the photo.

Installing drives into the

Storage Tower

Step 1

Slide the storage device into the embedded mounting bracket.

Step 2

Using 3.5” SATA Hard Disk Drives

Connect the internal SATA data cable to the data port of the hard drive then connect the

15-pin SATA power connector to the power port on the hard drive.

Step 3

Secure the hard disk by using screws provided. Repeat the above procedure for additional hard drives.

Hard Disk www.addonics.com

Technical Support (M-F 8:30am - 6:00pm PST) Phone: 408-453-6212 Email: www.addonics.com/support/query/

SATA Port 3

SATA Port 0

SATA Port 1

SATA Port 4

SATA Port 2

Drive activity LED Jumper Block (J1)

Error LED Jumper Block (J3)

Floppy

Power

Connector eSATA Host Port (Port 5) Dip Switch RAID Setting Button

Raid Mode

Individual Drive

(Factory Default)

0

1 and 10

3

5

Clone

Large

Dip Switch Settings

1 2 3 4 5

OFF OFF OFF OFF OFF

OFF

OFF

OFF

OFF

OFF OFF

OFF

Enable

ERR Buzzer

Function

OFF

Auto-

Rebuilding to Spare

Drive

OFF

OFF

OFF

OFF

ON

ON

ON

ON

ON

OFF

ON

OFF

OFF

OFF

ON

ON

OFF

OFF

ON

ON OFF

Port Multiplier Mode

ON www.addonics.com

Technical Support (M-F 8:30am - 6:00pm PST) Phone: 408-453-6212 Email: www.addonics.com/support/query/

Default factory DIP Switch setting:

SW1 – RAID Setting DIP Switch

1.

2.

3.

BZS – Error buzzer function

EZ – Automatic rebuilding to spare drive (one of the drives on the raid is set as a spare). If EZ is ENABLED anda drive failure occurs, the spare will automatically act as a drive replacement and rebuilding will automatically

start.

M2 – RAID mode 2

M1 – RAID mode 1

M0 – RAID mode 0 SW1

1 2 3 4 5

BZS EZ M2 M1 M0

Error buzzer function is ENABLED (BZS) when dip switch is in OFF position

Auto-rebuilding to spare drive is DISABLED (EZ)

Individual drive mode is ENABLED (M0~M2)

Note: When the default factory RAID setting is used, independent drive configuration and optical drive are supported only when connecting to controllers with Silicon

Image Sil3124, Sil3132 chip set or controllers that are Port Multiplier (PM) compatible. Simultaneous DVD writing was tested using the Nero Burning Rom.

LED Pin Header

J3 J1

P5 P0 P1 P2 P3 P4

Error LED

P5 P0 P1 P2 P3 P4

Activity LED

J1 – Drive Activity LED

P5 – Activity LED for eSATA host port lights up when it is connected to a

SATA controller card.

P0, P1, P2, P3 & P4 - Activity LEDs for port 0, 1, 2, 3, 4 & 5 light up when a drive is connected and blinks when there’s drive activity.

J3 – Error LED

P5 – error LED for eSATA host port

P0, P1, P2, P3 & P4 - error LED for port 0, 1, 2, 3, 4 & 5 www.addonics.com

Technical Support (M-F 8:30am - 6:00pm PST) Phone: 408-453-6212 Email: www.addonics.com/support/query/

1.

Setting or Modifying the RAID Mode Using the JMicron

HW RAID Manager Utility Program:

For Windows users, install the JMicron HW RAID Manager located on the

SATA Controller CD. In the CD, go to Configuration Utilities > JMB393. This manager can be use to create and monitor the status of the RAID volume.

2.

It is recommended to use the default factory RAID DIP switch setting when using the JMicron HW RAID Manager.

Modify the RAID mode on the 5-port HPM-XA using DIP switch

Recommended to be used on operating system without JMicron HW RAID

Manager support like Linux, Mac & Solaris. Windows users can also use the procedure below.

Note: Steps A to D need to be performed each time the raid mode is modified.

a. Set the DIP switch as shown below. b. c. d.

SW1

1 2 3 4 5

BZS EZ M2 M1 M0

Press the RAID setting button with a ball point pen.

While pressing the RAID setting button turn on the system power where the HPM is connected. The buzzer will sound while holding the

RAID setting button. Release it after at least 5 seconds for hardware initialization. A single beep will be heard to indicate initialization is completed. The above steps act as a reset.

Power off the system power.

www.addonics.com

Technical Support (M-F 8:30am - 6:00pm PST) Phone: 408-453-6212 Email: www.addonics.com/support/query/

e. On the DIP switch, change (M0 to M2) setting to the desired RAID mode using the diagram below.

All settings on the diagram shows

Error buzzer function is ENABLED

EZ function is DISABLED.

RAID 0 Mode Clone Mode

SW1

1 2 3 4 5

BZS EZ M2 M1 M0

RAID 1& RAID 10 Mode

SW1

1 2 3 4 5

BZS EZ M2 M1 M0

Large Mode

SW1

1 2 3 4 5

BZS EZ M2 M1 M0

RAID 3 Mode

SW1

1 2 3 4 5

BZS EZ M2 M1 M0

Individual Drives Mode

SW1

1 2 3 4 5

BZS EZ M2 M1 M0

SW1

1 2 3 4 5

BZS EZ M2 M1 M0

RAID 5 Mode

SW1

1 2 3 4 5

BZS EZ M2 M1 M0 www.addonics.com

Technical Support (M-F 8:30am - 6:00pm PST) Phone: 408-453-6212 Email: www.addonics.com/support/query/

RAID Setting Notes:

SW1

RAID 1& RAID 10 Mode

1 2 3 4 5

BZS EZ M2 M1 M0

When 2 drives are connected to the HPM-XA, and DIP switch is set to this setting, the 2 drives will be configured as a 2-drive

RAID1 array.

When 4 drives are connected to the HPM-XA, the 4 drives will be configured as a 4-drive RAID10 array.

SW1

Clone Mode

1 2 3 4 5

BZS EZ M2 M1 M0

Clone’s action is similar to

RAID1. However, all of the hard drives will be mirrored.

Clone mode is useful especially when users like to copy data from a source hard drive to the drives connected to the HPM-XA.

f. Press the RAID setting button with a ball point pen.

g. While pressing the RAID setting button turn on the system power where the HPM is connected. The buzzer will sound while holding the

RAID setting button. Release it after at least 5 seconds for hardware initialization. A single beep will be heard to indicate initialization is

completed. h. i. j. k.

Verify if the RAID array is detected by the system.

If the 5-port HPM-XA is connected to the motherboard onboard

SATA, on the CMOS setup utility, the raid array will display as

“Addonics H/W RAID5” if setup as a RAID5 array.

If the 5-port HPM-XA is connected to an eSATA host controller card, on the RAID BIOS, the raid array will display as “Addonics H/W

RAID0” if setup as a RAID0 array.

If booted into Windows, in Disk Drives under Device Manager, the raid array will display as “Addonics H/W LARGE” if setup as a l. Once raid array is verified, you can set the buzzer either ON or OFF.

www.addonics.com

Technical Support (M-F 8:30am - 6:00pm PST) Phone: 408-453-6212 Email: www.addonics.com/support/query/

f. Press the RAID setting button with a ball point pen.

g. While pressing the RAID setting button turn on the system power where the HPM is connected. The buzzer will sound while holding the

RAID setting button. Release it after at least 5 seconds for hardware initialization. A single beep will be heard to indicate initialization is

completed. h. i. j. k.

Verify if the RAID array is detected by the system.

If the 5-port HPM-XA is connected to the motherboard onboard

SATA, on the CMOS setup utility, the raid array will display as

“Addonics H/W RAID5” if setup as a RAID5 array.

If the 5-port HPM-XA is connected to an eSATA host controller card, on the RAID BIOS, the raid array will display as “Addonics H/W

RAID0” if setup as a RAID0 array.

If booted into Windows, in Disk Drives under Device Manager, the raid array will display as “Addonics H/W LARGE” if setup as a l. Once raid array is verified, you can set the buzzer either ON or OFF.

B.

A.

Notes on Spare Drives using the Easy RAID Setting (EZ)

When EZ function is ENABLED, the auto-rebuilding to spare drive is automatic.

The degraded RAID group will start rebuilding automatically by using the existing spare drive.

* Spare drive can be either plugged before RAID building or a new drive can be plug as the spare drive when RAID rebuild is required.

Which port acts as a spare drive?

The last drive will automatically become the spare drive.

For a 3-drive RAID5 with spare:

Drives connected to SATA ports 1~3 belong to the active RAID5 array and drive connected to port 4 is the spare.

For a 4-drive RAID10 with spare:

Drives connected to SATA ports 1~4 belong to the active RAID10 array and drive connected to port 5 is the spare.

For a 2-drive RAID1 with spare:

Drives connected to SATA ports 1& 4 belong to the active RAID1 array and drive connected to port 5 is the spare.

When will rebuild action start?

When the raid fails and EZ is enabled, the HPM-XA will automatically rebuild the RAID group using the spare.

When the raid fails and EZ is disabled, the HPM-XA will NOT rebuild the raid group unless you install a good drive to replace the

Connecting the Power Cable and Storage Tower to the

Computer

a. Connect the power cord provided from the wall outlet to the back of the

tower.

b. c.

Make sure the power is off (power LED light should be off).

Connect the eSATA cable from the back of the tower to the eSATA port on the

computer.

Power on/off control

a. A main power switch is located at the back of the tower. Turn the switch on.

Another auxiliary switch is located on the front of the tower.

b. Make sure the power is off on the auxiliary switch (power LED light should be

off).

c. Power on the tower www.addonics.com