HP (Hewlett-Packard) ML330 G6 Server User manual


Add to my manuals
137 Pages

advertisement

HP (Hewlett-Packard) ML330 G6 Server User manual | Manualzz

HP ProLiant ML330 G6 Server

User Guide

Part Number 534305-002

March 2010 (Second Edition)

© Copyright 2009, 2010 Hewlett-Packard Development Company, L.P.

The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein.

Microsoft, Windows, and Windows Server are U.S. registered trademarks of Microsoft Corporation.

Intended audience

This document is for the person who installs, administers, and troubleshoots servers and storage systems.

HP assumes you are qualified in the servicing of computer equipment and trained in recognizing hazards in products with hazardous energy levels.

Contents

Component identification ............................................................................................................... 7

Front panel components ................................................................................................................................ 7

Front panel LEDs and buttons ......................................................................................................................... 8

Rear panel components ................................................................................................................................ 9

Rear panel LEDs and buttons ....................................................................................................................... 10

System board components .......................................................................................................................... 11

System maintenance switch ............................................................................................................... 12

NMI functionality ............................................................................................................................. 13

System board LEDs ..................................................................................................................................... 13

System LEDs and internal health LED combinations ......................................................................................... 14

DIMM slots ................................................................................................................................................ 15

DIMM identification .................................................................................................................................... 15

SAS and SATA device numbers ................................................................................................................... 17

Hot-plug SATA or SAS hard drive LEDs ......................................................................................................... 18

Fan locations ............................................................................................................................................. 19

Operations................................................................................................................................. 20

Power up the server .................................................................................................................................... 20

Power down the server ............................................................................................................................... 20

Open or remove the tower bezel ................................................................................................................. 20

Extend the server from the rack .................................................................................................................... 21

Remove the access panel ............................................................................................................................ 21

Install the access panel ............................................................................................................................... 22

Remove the air baffle .................................................................................................................................. 22

Configure the air baffle ............................................................................................................................... 22

Remove the media bay blank ...................................................................................................................... 23

Remove a bezel blank ................................................................................................................................ 24

Remove the processor board ....................................................................................................................... 24

Install the processor board .......................................................................................................................... 25

Setup ......................................................................................................................................... 28

Optional installation services ....................................................................................................................... 28

Rack planning resources ............................................................................................................................. 28

Optimum environment................................................................................................................................. 28

Space and airflow requirements ........................................................................................................ 28

Temperature requirements ................................................................................................................. 29

Power requirements .......................................................................................................................... 30

Electrical grounding requirements ...................................................................................................... 30

Rack warnings ........................................................................................................................................... 30

Identifying the server shipping carton contents ............................................................................................... 31

Installing hardware options ......................................................................................................................... 31

Setting up a tower server ............................................................................................................................ 31

Installing a server in a rack ......................................................................................................................... 32

Installing the operating system ..................................................................................................................... 34

Registering the server.................................................................................................................................. 34

Hardware options installation ....................................................................................................... 35

Introduction ............................................................................................................................................... 35

Processor option......................................................................................................................................... 35

Memory options ......................................................................................................................................... 40

Memory subsystem architecture ......................................................................................................... 41

Single-, dual-, and quad-rank DIMMs ................................................................................................. 41

Memory configurations ..................................................................................................................... 41

General DIMM slot population guidelines ........................................................................................... 43

Installing DIMMs .............................................................................................................................. 47

Redundant hot-plug power supply option ...................................................................................................... 48

Power supply configuration ............................................................................................................... 49

Installing the redundant hot-plug power supply option .......................................................................... 49

Redundant fan assembly option ................................................................................................................... 50

SAS or SATA hard drive option ................................................................................................................... 52

Expansion hard drive cage option (hot-plug) ................................................................................................. 53

Expansion hard drive cage option (non-hot-plug) ........................................................................................... 55

Removable media devices ........................................................................................................................... 57

Identifying guide screws.................................................................................................................... 58

SATA optical drive option ................................................................................................................. 58

USB tape drive option ....................................................................................................................... 60

Full-height tape drive option .............................................................................................................. 61

Expansion board options ............................................................................................................................ 63

Removing the expansion slot cover ..................................................................................................... 63

Installing expansion boards ............................................................................................................... 64

PCI-X extender board option ........................................................................................................................ 65

Storage controller option ............................................................................................................................. 68

Battery-backed write cache battery pack option ............................................................................................. 68

FBWC module and capacitor pack option .................................................................................................... 70

SAS controller option .................................................................................................................................. 72

Dedicated iLO 2 port module option ............................................................................................................ 73

HP Trusted Platform Module option .............................................................................................................. 74

Installing the Trusted Platform Module board ....................................................................................... 75

Retaining the recovery key/password ................................................................................................. 76

Enabling the Trusted Platform Module ................................................................................................. 77

Cabling ..................................................................................................................................... 78

Non-hot-plug SATA hard drive cabling ......................................................................................................... 78

Non-hot-plug SATA/SAS hard drive cabling ................................................................................................. 79

Hot-plug SATA/SAS hard drive cabling ........................................................................................................ 79

Non-hot-plug hard drive single power cabling ............................................................................................... 80

Hot-plug hard drive single power cabling ..................................................................................................... 81

Non-hot-plug hard drive redundant power cabling ......................................................................................... 82

Hot-plug hard drive redundant power cabling ............................................................................................... 83

Configuration and utilities ............................................................................................................ 84

Configuration tools ..................................................................................................................................... 84

SmartStart software .......................................................................................................................... 84

HP ROM-Based Setup Utility .............................................................................................................. 85

Option ROM Configuration for Arrays................................................................................................ 87

HP ProLiant Essentials Rapid Deployment Pack .................................................................................... 88

Re-entering the server serial number and product ID ............................................................................. 88

Management tools...................................................................................................................................... 88

Automatic Server Recovery ................................................................................................................ 88

ROMPaq utility ................................................................................................................................. 89 iLO 2 technology ............................................................................................................................. 89

Erase Utility ..................................................................................................................................... 89

StorageWorks library and tape tools .................................................................................................. 90

HP Systems Insight Manager ............................................................................................................. 90

Management Agents ........................................................................................................................ 90

Redundant ROM support ................................................................................................................... 90

USB support .................................................................................................................................... 91

Internal USB functionality .................................................................................................................. 91

Diagnostic tools ......................................................................................................................................... 91

HP Insight Diagnostics ...................................................................................................................... 91

HP Insight Diagnostics survey functionality .......................................................................................... 92

Integrated Management Log .............................................................................................................. 92

Array Diagnostic Utility ..................................................................................................................... 92

HP Insight Server Migration software for ProLiant ................................................................................. 92

Remote support and analysis tools ............................................................................................................... 93

HP Insight Remote Support software ................................................................................................... 93

Keeping the system current .......................................................................................................................... 93

Drivers ............................................................................................................................................ 93

ProLiant Support Packs ...................................................................................................................... 94

Operating system version support ...................................................................................................... 94

System Online ROM flash component utility ........................................................................................ 94

Change control and proactive notification .......................................................................................... 94

Care Pack ....................................................................................................................................... 95

Troubleshooting .......................................................................................................................... 96

Troubleshooting resources ........................................................................................................................... 96

Pre-diagnostic steps .................................................................................................................................... 96

Important safety information .............................................................................................................. 96

Symptom information ........................................................................................................................ 98

Prepare the server for diagnosis ......................................................................................................... 99

Loose connections ...................................................................................................................................... 99

Service notifications .................................................................................................................................. 100

Troubleshooting flowcharts ........................................................................................................................ 100

Start diagnosis flowchart ................................................................................................................. 100

General diagnosis flowchart ............................................................................................................ 101

Server power-on problems flowchart ................................................................................................ 103

POST problems flowchart ................................................................................................................ 106

OS boot problems flowchart ............................................................................................................ 107

Server fault indications flowchart ..................................................................................................... 109

POST error messages and beep codes ....................................................................................................... 111

Battery replacement .................................................................................................................. 112

Regulatory compliance notices ................................................................................................... 113

Regulatory compliance identification numbers ............................................................................................. 113

Federal Communications Commission notice ............................................................................................... 113

FCC rating label ............................................................................................................................ 113

Class A equipment ......................................................................................................................... 113

Class B equipment .......................................................................................................................... 113

Declaration of conformity for products marked with the FCC logo, United States only ...................................... 114

Modifications ........................................................................................................................................... 114

Cables .................................................................................................................................................... 114

Canadian notice (Avis Canadien) .............................................................................................................. 115

European Union regulatory notice .............................................................................................................. 115

Disposal of waste equipment by users in private households in the European Union ........................................ 115

Japanese notice ....................................................................................................................................... 116

BSMI notice ............................................................................................................................................. 116

Korean notice .......................................................................................................................................... 117

Chinese notice ......................................................................................................................................... 117

Laser compliance ..................................................................................................................................... 117

Battery replacement notice ........................................................................................................................ 117

Taiwan battery recycling notice ................................................................................................................. 118

Power cord statement for Japan ................................................................................................................. 118

Electrostatic discharge ............................................................................................................... 119

Preventing electrostatic discharge .............................................................................................................. 119

Grounding methods to prevent electrostatic discharge .................................................................................. 119

Specifications ........................................................................................................................... 120

Environmental specifications ...................................................................................................................... 120

Mechanical specifications ......................................................................................................................... 120

Power supply specifications ....................................................................................................................... 121

Technical support ...................................................................................................................... 123

Before you contact HP .............................................................................................................................. 123

HP contact information .............................................................................................................................. 123

Customer Self Repair ................................................................................................................................ 123

Acronyms and abbreviations ...................................................................................................... 131

Index ....................................................................................................................................... 134

Component identification

Front panel components

Item Description

3

4

1

2

5

Optical drive

USB connectors (2)

Standard hard drive bays (4)

Expansion hard drive bays (4)

Media bays (2)

Component identification 7

Front panel LEDs and buttons

Item Description

1

2

3

4

5

System health LED

NIC 1 link/activity LED

NIC 2 link/activity LED

Drive activity LED

Power On/Stand by button and system power LED

Status

Green = System health is normal.

Amber = System health is degraded. To identify the component in

a degraded state, see "System board LEDs (on page 13 )."

Red = System health is critical. To identify the component in a

critical state, see "System board LEDs (on page 13 )."

Off = System health is normal (when in standby mode).

Green or flashing green = Activity exists.

Off = No activity exists.

If power is off, view the LEDs on the RJ-45 connector. See "Rear

panel LEDs and buttons (on page 10 )."

Green = Link exists.

Off = No link exists.

If power is off, view the LEDs on the RJ-45 connector. See "Rear

panel LEDs and buttons (on page 10 )."

Green = Drive activity is normal.

Off = No drive activity exists.

Green = Power is on.

Amber = System is in standby mode.

Component identification 8

Rear panel components

12

13

14

15

16

7

8

9

5

6

10

11

Item Description

3

4

1

2

Dedicated iLO 2 management port (optional)

Serial connector

10/100/1000 NIC 2 connector

10/100/1000 NIC 1 connector/shared iLO 2 management port

Mouse connector

Power supply 1

Power supply blank

Slot 1 PCI-X*

Slot 2 PCI-X*

Slot 3 PCIe1 x8 (1)

Slot 4 PCIe2 x16 (16, 8, 4, 2, 1)

Slot 5 PCIe2 x8 (4, 2, 1)

Slot 6 PCIe2 x8 (4, 2, 1)

Video connector

USB connectors (2)

Keyboard connector

Component identification 9

*Slots 1 and 2 are available only when an optional PCI-X extender board is installed.

Rear panel LEDs and buttons

2

3

Item

1

Description Status

UID button/LED Blue = Activated

Flashing = System is being managed remotely.

Off = Deactivated

NIC/iLO 2 activity Green or flashing green = Activity exists.

Off = No activity exists.

NIC/iLO 2 link Green = Link exists.

Off = No link exists.

Component identification 10

System board components

For this server, some system board slots and connectors are reserved.

Item

6

7

4

5

1

2

3

8

9

10

11

12

17

18

19

20

13

14

15

16

21

22

Description

Hard drive backplane connectors (2)

Internal USB connector

Redundant power supply connector

Front panel connector

Reserved

SATA connectors 1-4 (hard drive)

Hard drive LED connector

System maintenance switch

SATA connectors 5-6 (optical drive)

Slot 3 PCIe1 x8 (1)

SD card slot

Slot 4 PCIe2 x16 (16, 8, 4, 2, 1)

Slot 5 PCIe2 x8 (4, 2, 1)

Slot 6 PCIe2 x8 (4, 2, 1)

Fan 6 connector

Dedicated iLO 2 module connector (optional)

Hard drive backplane connector

NMI jumper

Processor board connectors

TPM connector

Processor 1 DIMMs (1-9)

USB connector

Component identification 11

Item Description

27

28

29

30

23

24

25

26

System power connector

Fan 1 connector

Fan 1.5 or 2 connector

Fan 3 connector

Reserved

Processor socket 1 (populated)

Battery

Reserved

31 Power connector

32 Front USB connector

* The server supports one optical drive that can be connected to either SATA connector 5 or SATA connector 6.

System maintenance switch

Position Default Function

S1 Off

S2

S3

S4

S5

S6

S7

Off

Off

Off

Off

Off

Off

Off = iLO 2 security is enabled.

On = iLO 2 security is disabled.

Off = Normal operation

On = RBSU will not commit any configuration changes.*

Reserved

Reserved

Off = Power-on password enabled

On = Power-on password disabled*

Off = Normal operation

On = BIOS will clear CMOS and

NVRAM.*

Reserved

S8 Off

* "On" activates the function.

Reserved

Component identification 12

NMI functionality

An NMI crash dump enables administrators to create crash dump files when a system is hung and not responding to traditional debug mechanisms.

Crash dump log analysis is an essential part of diagnosing reliability problems, such as hangs in operating systems, device drivers, and applications. Many crashes freeze a system, and the only available action for administrators is to cycle the system power. Resetting the system erases any information that could support problem analysis, but the NMI feature preserves that information by performing a memory dump before a hard reset.

To force the OS to invoke the NMI handler and generate a crash dump log, the administrator can do any of the following:

Short the NMI jumper pins

Press the NMI switch

Use the iLO Virtual NMI feature

For additional information, see the whitepaper on the HP website

( http://h20000.www2.hp.com/bc/docs/support/SupportManual/c00797875/c00797875.pdf

).

System board LEDs

2

3

Item

1

LED description

Processor failure

Fan 6 failure

Power supply

Status

Amber = Processor has failed.

Off = Normal

Amber = Fan has failed or is missing.

Off = Normal

Off = No AC power or failed power supply

Green = Power supply is on and is functioning.

Component identification 13

Item

4

5

6

7

8

LED description Status

Overtemperature Amber = System has reached a cautionary or critical temperature level.

Off = Normal

Fan 1 failure Amber = Fan has failed or is missing.

Off = Normal

Fan 1.5 or 2 failure Amber = Fan has failed or is missing.

Off = Normal

DIMM failure (1-9) Amber = DIMM has failed or is missing.

Off = Normal

Fan 3 failure Amber = Fan has failed or is missing.

Off = Normal

System LEDs and internal health LED combinations

When the internal health LED on the front panel illuminates either amber or red, the server is experiencing a health event. Combinations of illuminated system LEDs and the internal health LED indicate system status.

The front panel health LEDs indicate only the current hardware status. In some situations, HP SIM may report server status differently than the health LEDs because the software tracks more system attributes.

System LED and

Color

Internal Health

LED Color

Status

Processor failure

(amber)

Red

Amber

One or more of the following conditions may exist:

Processor has failed.

Processor is not installed in the socket.

Processor is unsupported.

ROM detects a failed processor during POST.

Processor is in a pre-failure condition.

DIMM failure, slot X

(amber)

Red

Amber

Red

DIMM in slot X has failed.

DIMM in slot X is an unsupported type, and no valid memory exists in another channel.

DIMM in slot X has reached the single-bit correctable error threshold.

DIMM in slot X is in a pre-failure condition.

DIMM in slot X is an unsupported type, but valid memory exists in another channel.

No valid or usable memory is installed in the system. DIMM failure, all slots in one channel

(amber)

Amber

Overtemperature

(amber)

Amber

The entire channel is not populated.

DIMMs do not match within the channel, but other valid memory is available.

The Health Driver has detected a cautionary temperature level.

Component identification 14

System LED and

Color

Internal Health

LED Color

Red

Status

Fan module (amber) Red

Power supply (amber) Red

The server has detected a hardware critical temperature level.

The minimum fan requirements are not being met in one or more of the fan modules. One or more fans have failed or are missing.

One or more of the following conditions may exist:

There is no AC power.

The power supply has failed.

There is a power supply mismatch at POST. Amber

DIMM slots

DIMM slots are numbered sequentially (1 through 9) for each processor. The supported AMP modes use the letter assignments for population guidelines.

DIMM identification

IMPORTANT:

This server does not support mixing RDIMMs and UDIMMs. Attempting to mix these two types causes the server to halt during BIOS initialization.

Component identification 15

The memory subsystem may be populated with either RDIMMs or UDIMMs, but mixing the two types is not supported. To determine DIMM characteristics, use the label attached to the DIMM and the following illustration and table.

Item Description

1

2

3

4

5

Size

Rank

Data width

Memory speed

DIMM type

Definition

1R = Single-rank

2R = Dual-rank

4R = Quad-rank x4 = 4-bit x8 = 8-bit

10600 = 1333-MHz

8500 = 1066-MHz

R = RDIMM (registered)

E = UDIMM (unbuffered with ECC)

For the latest supported memory information, see the QuickSpecs on the HP website

( http://www.hp.com

).

Component identification 16

SAS and SATA device numbers

Standard configuration

Optional configuration with hard drive expansion cage

Component identification 17

Hot-plug SATA or SAS hard drive LEDs

Item LED description

1

2

Fault/UID status

Online/Activity status

Status

Amber = Drive failure

Flashing amber = Fault-process activity

Blue = Unit identification is active

Off = No fault-process activity

Green = Drive activity

Flashing green = High activity on the drive or drive is being configured as part of an array

Off = No drive activity

The online/activity status LED will not illuminate if using SATA drives connected to the embedded storage device. In this configuration, SATA hard drive activity can be identified using the hard drive activity LED on the system front panel.

Component identification 18

Fan locations

Standard fan configuration

Redundant fan configuration

Component identification 19

Operations

Power up the server

To power up the server, press the Power On/Standby button.

Power down the server

WARNING: To reduce the risk of personal injury, electric shock, or damage to the equipment, remove the power cord to remove power from the server. The front panel Power

On/Standby button does not completely shut off system power. Portions of the power supply and some internal circuitry remain active until AC power is removed.

IMPORTANT: If installing a hot-plug device, it is not necessary to power down the server.

1.

2.

Back up the server data.

Shut down the operating system as directed by the operating system documentation.

NOTE:

If the operating system automatically places the server in Standby mode, omit the next step.

3.

Press the Power On/Standby button to place the server in Standby mode. When the server activates

Standby power mode, the system power LED changes to amber.

IMPORTANT: Pressing the UID button illuminates the blue UID LEDs on the front and rear panels. In a rack environment, this feature facilitates locating a server when moving between the front and rear of the rack.

4.

Disconnect the power cords.

The system is now without power.

Open or remove the tower bezel

This server has a removable bezel that must be unlocked and opened before accessing the front panel components. The bezel should remain closed during normal server operations.

CAUTION: To avoid injury, HP recommends that only authorized technicians keep the bezel key.

CAUTION:

To avoid breaking the bezel, remove the bezel before placing the server on its side.

To remove the component:

1.

Power down the server (on page 20 ).

Operations 20

2.

3.

Using the key provided with the server, unlock the bezel.

Remove the bezel, as needed.

Extend the server from the rack

NOTE: If the optional cable management arm option is installed, you can extend the server without powering down the server or disconnecting peripheral cables and power cords.

These steps are only necessary with the standard cable management solution.

1.

2.

3.

Power down the server (on page 20 ).

Disconnect all peripheral cables and power cords from the server rear panel.

Extend the tray.

WARNING: To reduce the risk of personal injury or equipment damage, be sure that the rack is adequately stabilized before extending a component from the rack.

WARNING:

To reduce the risk of personal injury, be careful when pressing the server railrelease latches and sliding the server into the rack. The sliding rails could pinch your fingers.

4.

5.

After performing the installation or maintenance procedure, slide the server back into the rack: a.

Press the server rail-release latches and slide the server fully into rack. b.

Secure the server by tightening the thumbscrews.

Reconnect the peripheral cables and power cords.

Remove the access panel

1.

2.

Power down the server (on page 20 ).

Do one of the following: o

Open or remove the tower bezel, as needed (" Open or remove the tower bezel " on page 20 ).

o

Extend the server from the rack (on page 21 ).

Operations 21

3.

4.

5.

Loosen the access panel screws.

Slide the access panel back about 1.5 cm (0.5 in).

Lift and remove the access panel.

CAUTION:

For proper cooling, do not operate the server without the access panel, baffles, expansion slot covers, hard drives, or blanks installed.

Install the access panel

1.

2.

Place the access panel on top of the server, allowing it to extend past the rear of the server approximately 1.5 cm (0.5 in).

Slide the access panel forward until it clicks into place, and close the access panel latch.

Remove the air baffle

1.

2.

3.

4.

Power down the server (on page 20 ).

Do one of the following: o

Open or remove the tower bezel, as needed (" Open or remove the tower bezel " on page 20 ).

o

Extend the server from the rack (on page 21 ).

Remove the access panel (on page 21 ).

Remove the air baffle.

If necessary, configure the air baffle (on page 22 ).

Configure the air baffle

This procedure is necessary for 2P models only.

1.

2.

Power down the server (on page 20 ).

Do one of the following:

Operations 22

3.

4.

5. o o

Open or remove the tower bezel, as needed (" Open or remove the tower bezel " on page 20 ).

Extend the server from the rack (on page

Remove the access panel (on page 21 ).

21 ).

Remove the air baffle (on page 22 ).

Press and hold the release button.

6.

Remove the partition.

Remove the media bay blank

1.

2.

Power down the server (on page 20 ).

Open or remove the tower bezel, as needed (" Open or remove the tower bezel " on page 20 ).

CAUTION:

Always populate each media bay with either a device or a blank. Proper airflow can only be maintained when the bays are populated. Unpopulated drive bays can lead to improper cooling and thermal damage.

Operations 23

3.

Remove the media bay blank.

Remove a bezel blank

1.

2.

3.

Power down the server (on page 20 ).

Remove the front bezel (" Open or remove the tower bezel " on page 20 ).

Remove a bezel blank.

Remove the processor board

1.

2.

3.

4.

5.

6.

Power down the server (on page 20 ).

Do one of the following: o

Open or remove the tower bezel, as needed (" Open or remove the tower bezel " on page 20 ).

o

Extend the server from the rack (on page 21 ).

Remove the access panel (on page 21 ).

Place the tower server on its side.

Remove the air baffle (on page 22 ).

Disconnect the power cable from the processor board.

Operations 24

7.

8.

Using a T-15 Torx screwdriver, remove the screws securing the processor board.

Remove the processor board.

9.

10.

Using the wrench provided in the kit, remove the mezzanine support stand-offs.

Remove the metal plate.

Install the processor board

1.

2.

3.

4.

5.

Power down the server (on page 20 ).

Do one of the following: o

Open or remove the tower bezel, as needed (" Open or remove the tower bezel " on page 20 ).

o

Extend the server from the rack (on page 21 ).

Remove the access panel (on page 21 ).

Place the tower server on its side.

Remove the air baffle (on page 22 ).

Operations 25

6.

Using a T-15 Torx screwdriver, remove the seven screws on the system board.

Save the screws.

7.

Using the wrench provided in the kit, install the seven mezzanine base stand-offs.

8.

Install the metal plate on the mezzanine base stand-offs.

Operations 26

9.

Using the wrench from the kit, install the mezzanine support stand-offs.

10.

11.

Install the processor board.

Using the screws removed from the system board, secure the processor board.

Operations 27

Setup

Optional installation services

Delivered by experienced, certified engineers, HP Care Pack services help you keep your servers up and running with support packages tailored specifically for HP ProLiant systems. HP Care Packs let you integrate both hardware and software support into a single package. A number of service level options are available to meet your needs.

HP Care Pack Services offer upgraded service levels to expand your standard product warranty with easyto-buy, easy-to-use support packages that help you make the most of your server investments. Some of the

Care Pack services are:

Hardware support o

6-Hour Call-to-Repair o o

4-Hour 24x7 Same Day

4-Hour Same Business Day

Software support o

Microsoft® o o

Linux

HP ProLiant Essentials (HP SIM and RDP)

Startup and implementation services for both hardware and software

For more information on Care Packs, refer to the HP website

( http://www.hp.com/hps/carepack/servers/cp_proliant.html

).

Rack planning resources

The rack resource kit ships with all HP branded or Compaq branded 9000, 10000, and H9 series racks.

For more information on the content of each resource, refer to the rack resource kit documentation.

If you intend to deploy and configure multiple servers in a single rack, refer to the white paper on highdensity deployment at the HP website ( http://www.hp.com/products/servers/platforms ).

Optimum environment

When installing the server in a rack, select a location that meets the environmental standards described in this section.

Space and airflow requirements

To allow for servicing and adequate airflow, observe the following space and airflow requirements when deciding where to install a rack:

Setup 28

Leave a minimum clearance of 63.5 cm (25 in) in front of the rack.

Leave a minimum clearance of 76.2 cm (30 in) behind the rack.

Leave a minimum clearance of 121.9 cm (48 in) from the back of the rack to the back of another rack or row of racks.

HP servers draw in cool air through the front door and expel warm air through the rear door. Therefore, the front and rear rack doors must be adequately ventilated to allow ambient room air to enter the cabinet, and the rear door must be adequately ventilated to allow the warm air to escape from the cabinet.

CAUTION:

To prevent improper cooling and damage to the equipment, do not block the ventilation openings.

When vertical space in the rack is not filled by a server or rack component, the gaps between the components cause changes in airflow through the rack and across the servers. Cover all gaps with blanking panels to maintain proper airflow.

CAUTION: Always use blanking panels to fill empty vertical spaces in the rack. This arrangement ensures proper airflow. Using a rack without blanking panels results in improper cooling that can lead to thermal damage.

The 9000 and 10000 Series Racks provide proper server cooling from flow-through perforations in the front and rear doors that provide 64 percent open area for ventilation.

CAUTION: When using a Compaq branded 7000 Series rack, you must install the high airflow rack door insert [P/N 327281-B21 (42U) or P/N 157847-B21 (22U)] to provide proper front-to-back airflow and cooling.

CAUTION: If a third-party rack is used, observe the following additional requirements to ensure adequate airflow and to prevent damage to the equipment:

Front and rear doors—If the 42U rack includes closing front and rear doors, you must allow 5,350 sq cm (830 sq in) of holes evenly distributed from top to bottom to permit adequate airflow (equivalent to the required 64 percent open area for ventilation).

Side—The clearance between the installed rack component and the side panels of the rack must be a minimum of 7 cm (2.75 in).

Temperature requirements

To ensure continued safe and reliable equipment operation, install or position the system in a wellventilated, climate-controlled environment.

The maximum recommended ambient operating temperature (TMRA) for most server products is 35°C

(95°F). The temperature in the room where the rack is located must not exceed 35°C (95°F).

CAUTION:

To reduce the risk of damage to the equipment when installing third-party options:

Do not permit optional equipment to impede airflow around the server or to increase the internal rack temperature beyond the maximum allowable limits.

• Do not exceed the manufacturer’s TMRA.

Setup 29

Power requirements

Installation of this equipment must comply with local and regional electrical regulations governing the installation of information technology equipment by licensed electricians. This equipment is designed to operate in installations covered by NFPA 70, 1999 Edition (National Electric Code) and NFPA-75, 1992

(code for Protection of Electronic Computer/Data Processing Equipment). For electrical power ratings on options, refer to the product rating label or the user documentation supplied with that option.

WARNING:

To reduce the risk of personal injury, fire, or damage to the equipment, do not overload the AC supply branch circuit that provides power to the rack. Consult the electrical authority having jurisdiction over wiring and installation requirements of your facility.

CAUTION: Protect the server from power fluctuations and temporary interruptions with a regulating uninterruptible power supply (UPS). This device protects the hardware from damage caused by power surges and voltage spikes and keeps the system in operation during a power failure.

When installing more than one server, you may need to use additional power distribution devices to safely provide power to all devices. Observe the following guidelines:

Balance the server power load between available AC supply branch circuits.

Do not allow the overall system AC current load to exceed 80 percent of the branch circuit AC current rating.

Do not use common power outlet strips for this equipment.

Provide a separate electrical circuit for the server.

Electrical grounding requirements

The server must be grounded properly for proper operation and safety. In the United States, you must install the equipment in accordance with NFPA 70, 1999 Edition (National Electric Code), Article 250, as well as any local and regional building codes. In Canada, you must install the equipment in accordance with Canadian Standards Association, CSA C22.1, Canadian Electrical Code. In all other countries, you must install the equipment in accordance with any regional or national electrical wiring codes, such as the International Electrotechnical Commission (IEC) Code 364, parts 1 through 7.

Furthermore, you must be sure that all power distribution devices used in the installation, such as branch wiring and receptacles, are listed or certified grounding-type devices.

Because of the high ground-leakage currents associated with multiple servers connected to the same power source, HP recommends the use of a PDU that is either permanently wired to the building’s branch circuit or includes a nondetachable cord that is wired to an industrial-style plug. NEMA locking-style plugs or those complying with IEC 60309 are considered suitable for this purpose. Using common power outlet strips for the server is not recommended.

Rack warnings

Setup 30

WARNING:

To reduce the risk of personal injury or damage to the equipment, be sure that:

The leveling jacks are extended to the floor.

The full weight of the rack rests on the leveling jacks.

• The stabilizing feet are attached to the rack if it is a single-rack installation.

• The racks are coupled together in multiple-rack installations.

Only one component is extended at a time. A rack may become unstable if more than one component is extended for any reason.

WARNING: To reduce the risk of personal injury or equipment damage when unloading a rack:

• At least two people are needed to safely unload the rack from the pallet. An empty 42U rack can weigh as much as 115 kg (253 lb), can stand more than 2.1 m (7 ft) tall, and may become unstable when being moved on its casters.

Never stand in front of the rack when it is rolling down the ramp from the pallet. Always handle the rack from both sides.

Identifying the server shipping carton contents

Unpack the server shipping carton and locate the materials and documentation necessary for installing the server. All the rack mounting hardware necessary for installing the server into the rack is included with the rack or the server.

The contents of the server shipping carton include:

Server

Printed setup documentation, Documentation CD, and software products

Power cord

Rack mounting hardware kit and documentation

In addition to these supplied items, you may need:

Application software CDs or diskettes

Options to be installed

T-10/T-15 Torx screwdriver

Installing hardware options

Install any hardware options before initializing the server. For options installation information, refer to the option documentation. For server-specific information, refer to "Hardware options installation (on page

35 )."

Setting up a tower server

Follow the steps in this section to set up a tower model server. If you are going to install the server into a

rack, refer to the rack installation (" Installing a server in a rack " on page 32 ) section.

1.

Connect peripheral devices to the server.

Setup 31

2.

3.

WARNING: To reduce the risk of electric shock, fire, or damage to the equipment, do not plug telephone or telecommunications connectors into RJ-45 connectors.

Connect the power cord to the rear of the server.

Connect the power cord to the AC power source.

WARNING: To reduce the risk of electric shock or damage to the equipment:

Do not disable the power cord grounding plug. The grounding plug is an important safety feature.

• Plug the power cord into a grounded (earthed) electrical outlet that is easily accessible at all times.

• Unplug the power cord from the power supply to disconnect power to the equipment.

• Do not route the power cord where it can be walked on or pinched by items placed against it. Pay particular attention to the plug, electrical outlet, and the point where the cord extends from the server.

Installing a server in a rack

The procedure to install the tray in the rack is similar to the procedures to install a server in a rack. For more information, see the 2U Quick Deploy Rail System Installation Instructions that shipped in the rail kit.

CAUTION: To avoid damage to the equipment, be sure that the rack rails are installed in a predetermined location on the rack so that airflow clearance issues are resolved. For airflow clearance information, refer to the documentation that ships with the server.

To install the component:

1.

See the "Installing the Product into a Rack" section of the 2U Quick Deploy Rack Rail System

Installation Instructions to do the following: a.

Install the component rails on the tray.

2. b.

Install the rack rails in the rack.

Install the tray onto the rack rails, and then partially slide the assembly into the rack.

Setup 32

3.

Attach the straps to the tray.

4.

Place the server on the tray, and then secure the server to the tray.

CAUTION: To prevent damage to equipment, do not place the monitor on a rack-mounted server. The rack enabling kit supports only the server.

5.

Slide the tray fully into the rack, and then tighten the thumbscrews.

Setup 33

6.

Slide the locking bracket forward, and then tighten the thumbscrews.

Installing the operating system

To operate properly, the server must have a supported operating system. For the latest information on supported operating systems, refer to the HP website ( http://www.hp.com/go/supportos ).

Two methods are available to install an operating system on the server:

SmartStart assisted installation—Insert the SmartStart CD into the CD-ROM drive and reboot the server.

Manual installation—Insert the operating system CD into the CD-ROM drive and reboot the server.

This process may require you to obtain additional drivers from the HP website

( http://www.hp.com/support ).

Follow the on-screen instructions to begin the installation process.

For information on using these installation paths, refer to the SmartStart installation poster in the HP

ProLiant Essentials Foundation Pack, included with the server.

Registering the server

To register the server, refer to the HP Registration website ( http://register.hp.com

).

Setup 34

Hardware options installation

Introduction

If more than one option is being installed, read the installation instructions for all the hardware options and identify similar steps to streamline the installation process.

WARNING:

To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system components to cool before touching them.

CAUTION: To prevent damage to electrical components, properly ground the server before beginning any installation procedure. Improper grounding can cause electrostatic discharge.

Processor option

The server supports single- and dual-processor operation. With two processors installed, the server supports boot functions through the processor installed in processor socket 1. However, if processor 1 fails, the system automatically boots from processor 2 and provides a processor failure message.

WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system components to cool before touching them.

CAUTION: To avoid damage to the system board:

• Do not touch the processor socket contacts.

Always install the processor socket cover after removing the processor from the socket.

• Do not tilt or slide the processor when lowering the processor into the socket.

CAUTION:

To avoid damage to the processor:

Handle the processor only by the edges.

• Do not touch the bottom of the processor, especially the contact area.

CAUTION:

To prevent possible server malfunction and damage to the equipment, multiprocessor configurations must contain processors with the same part number.

CAUTION: To prevent possible server overheating, always populate processor socket 2 with a processor and a heatsink or a processor socket cover and a heatsink blank.

CAUTION: The heatsink thermal interface media is not reusable and must be replaced if the heatsink is removed from the processor after it has been installed.

CAUTION: To prevent possible server malfunction and damage to the equipment, multiprocessor configurations must contain the same type of processors.

Hardware options installation 35

IMPORTANT: When installing the heatsink, align the guide pins on the processor retention bracket with the alignment holes in the heatsink.

IMPORTANT: Processor socket 1 must always be populated. If processor socket 1 is empty, the server does not power up.

NOTE: Do not discard the processor protective cover. Always install the processor protective cover if the processor is removed from the socket.

CAUTION: To help avoid damage to the processor and system board, do not install the processor without using the processor installation tool.

To install the component:

1.

Update the system ROM.

Locate and download the latest ROM version from the HP website ( http://www.hp.com/support ).

Follow the instructions on the website to update the system ROM.

2.

3.

4.

Power down the server (on page 20 ).

Disconnect all power cords from the power source.

Disconnect power cords from the server.

5.

6.

7.

8.

9.

10.

11.

Do one of the following: o

Open or remove the tower bezel, as needed (" Open or remove the tower bezel " on page 20 ).

o

Extend the server from the rack (on page 21 ).

Remove the access panel (on page 21 ).

Place the tower server on its side.

Remove the air baffle (on page 22 ).

Configure the air baffle (on page 22 ).

Install the processor board (on page 25 ).

Connect an available system power cable to the processor board.

12.

Open the processor retaining latch and the processor socket retaining bracket.

Hardware options installation 36

13.

Remove the processor socket protective cover.

IMPORTANT: Be sure the processor remains inside the processor installation tool.

14.

If the processor has separated from the installation tool, carefully re-insert the processor in the tool.

Hardware options installation 37

15.

Align the processor installation tool with the socket and install the processor.

16.

Press down firmly until the processor installation tool clicks and separates from the processor, and then remove the processor installation tool.

Hardware options installation 38

17.

Close the processor socket retaining bracket and the processor retaining latch.

18.

Remove the heatsink protective cover.

19.

Install the heatsink.

Hardware options installation 39

Be sure the airflow arrow on the heatsink points toward the rear of the server.

20.

21.

22.

23.

24.

25.

26.

(Optional) To optimize performance, install DIMMs into the processor 2 DIMM slots (" Installing

DIMMs " on page 47 ).

For the location of the processor 2 DIMM slots, see "System board components (on page 11 )."

Install the air baffle.

Install the access panel (on page 22 ).

Do one of the following: o o

Close or install the tower bezel, as needed.

Slide the server back into the rack.

Connect all power cords to the server.

Connect power cords to the power source.

Power up the server (on page 20 ).

Memory options

IMPORTANT: This server does not support mixing RDIMMs and UDIMMs. Attempting to mix these two types causes the server to halt during BIOS initialization.

The memory subsystem in this server can support RDIMMs or UDIMMs. Both types are referred to as

DIMMs when the information applies to both types. When specified as RDIMM or UDIMM, the information applies to that type only. All memory installed in the server must be the same type.

The server supports the following DIMM speeds:

Single- and dual-rank PC3-10600 (DDR-1333) DIMMs operating at 1333 and 1066 MHz

Quad-rank PC3-8500 (DDR-1067) DIMMs operating at 1066 MHz

Depending on the processor model, the number of DIMMs installed, and whether UDIMMs or RDIMMs are installed, the memory clock speed may be reduced to 1066 or 800 MHz. For more information on

the effect of DIMM slot population, see "General DIMM slot population guidelines (on page 43 )."

Hardware options installation 40

Memory subsystem architecture

The memory subsystem in this server is divided into channels. Each processor supports three channels, and each channel supports three DIMM slots, as shown in the following table.

Channel Slot Slot number

1

2

3 I

F

C

H

E

B

G

D

A

7

8

9

4

5

6

1

2

3

This multi-channel architecture provides enhanced performance in Advanced ECC mode. This architecture also enables the Mirrored Memory and Lockstep memory modes. This server supports both Registered

PC3 DIMMs (RDIMMs) and Unbuffered DIMMs (UDIMMs).

DIMM slots in this server are identified by number and by letter. Letters identify the slots to populate for specific AMP modes. Slot numbers are reported by ROM messages during boot and for error reporting.

Single-, dual-, and quad-rank DIMMs

To understand and configure memory protection modes properly, an understanding of single-, dual-, and quad-rank DIMMs is helpful. Some DIMM configuration requirements are based on these classifications.

A single-rank DIMM has one set of memory chips that is accessed while writing to or reading from the memory. A dual-rank DIMM is similar to having two single-rank DIMMs on the same module, with only one rank accessible at a time. A quad-rank DIMM is, effectively, two dual-rank DIMMs on the same module. Only one rank is accessible at a time. The server memory control subsystem selects the proper rank within the DIMM when writing to or reading from the DIMM.

Dual- and quad-rank DIMMs provide the greatest capacity with the existing memory technology. For example, if current DRAM technology supports 2-GB single-rank DIMMs, a dual-rank DIMM would be 4-

GB, and a quad-rank DIMM would be 8-GB.

Memory configurations

To optimize server availability, the server supports the following AMP modes:

Advanced ECC—provides the greatest memory capacity for a given DIMM size, while providing up to 4-bit error correction. This mode is the default option for this server.

Mirrored Memory—provides maximum protection against failed DIMMs. Uncorrectable errors in one channel are corrected by the mirror channel.

Lockstep—provides enhanced protection while making all installed memory available to the operating system. The server can continue to function if a single- or mulit-bit memory failure within a single DRAM device occurs.

Hardware options installation 41

Advanced Memory Protection options are configured in RBSU. If the requested AMP mode is not supported by the installed DIMM configuration, the server boots in Advanced ECC mode. For more

information, see "HP ROM-Based Setup Utility (on page 85 )."

For the latest memory configuration information, see the QuickSpecs on the HP website

( http://www.hp.com

).

RDIMM maximum memory configurations

The following table lists the maximum memory configuration possible with 8-GB RDIMMs.

Rank Processor

Single-rank

Dual-rank

Quad-rank

72 GB

72 GB

48 GB

UDIMM maximum memory configurations

The server supports a maximum of 24 GB using 4-GB dual-rank UDIMMs.

Low voltage DIMMs

Low Voltage DDR3 DIMMs operate at a lower voltage (1.35V) than standard voltage DDR3 DIMMs

(1.5V), and therefore consume less power. However, LVDIMMs are configured to operated at standard voltage levels (1.5V) under the following conditions:

If LVDIMMs are mixed with standard DDR3 DIMMs on the same server, the LVDIMMs operate at

1.5V.

If there are two dual-rank LVDIMMs per channel on any populated memory channel in the system running at 1333 MHz, the LVDIMMs operate at 1.5V.

This setting preserves maximum memory subsystem performance. To have DIMMs operate at 1.35V, configure the Maximum Memory Bus Frequency option in the ROM-Based Setup Utility to 1066

MHz.

If there is one quad-rank LVDIMM per channel on any populated memory channel in the system running at 1066 MHz, the LVDIMMs operate at 1.5V.

This setting preserves maximum memory subsystem performance. To have DIMMs operate at 1.35V, configure the Maximum Memory Bus Frequency option in the ROM-Based Setup Utility to 800 MHz.

LVDIMMs are only supported for use with the Intel® Xeon® 5600 series of processors.

Advanced ECC memory configuration

Advanced ECC memory is the default memory protection mode for this server. Standard ECC can correct single-bit memory errors and detect multi-bit memory errors. When multi-bit errors are detected using

Standard ECC, the error is signaled to the server and causes the server to halt.

Advanced ECC protects the server against some multi-bit memory errors. Advanced ECC can correct both single-bit memory errors and 4-bit memory errors if all failed bits are on the same DRAM device on the

DIMM.

Hardware options installation 42

Advanced ECC provides additional protection over Standard ECC because it is possible to correct certain memory errors that would otherwise be uncorrected and result in a server failure. The server provides notification that correctable error events have exceeded a pre-defined threshold rate.

Mirrored memory configuration

Mirroring provides protection against uncorrected memory errors that would otherwise result in server downtime. Mirroring is performed at the channel level. Channels 1 and 2 are used; channel 3 is not populated.

Data is written to both memory channels. Data is read from one of the two memory channels. If an uncorrectable error is detected in the active memory channel, data is retrieved from the mirror channel.

This channel becomes the new active channel, and the system disables the channel with the failed DIMM.

Online Spare memory configuration

Online spare memory provides protection against degraded DIMMs by reducing the likelihood of uncorrected memory errors. This protection is available without any operating system support.

Online spare memory protection dedicates one rank of each memory channel for use as spare memory.

The remaining ranks are available for OS and application use. If correctable memory errors occur at a rate higher than a specific threshold on any of the non-spare ranks, the server automatically copies the memory contents of the degraded rank to the online spare rank. The server then deactivates the failing rank and automatically switches over to the online spare rank.

Lockstep memory configuration

Lockstep mode provides protection against multi-bit memory errors that occur on the same DRAM device.

Lockstep mode can correct any single DRAM device failure on x4 and x8 DIMM types. The DIMMs in each channel must have identical HP part numbers.

Lockstep mode uses channel 1 and channel 2. Channel 3 is not populated. Because channel 3 cannot be populated when using Lockstep mode, the maximum memory capacity is lower than Advanced ECC mode. Memory performance with Advanced ECC is also slightly higher.

General DIMM slot population guidelines

Observe the following guidelines for all AMP modes:

Populate DIMM slots for a processor only if the processor is installed.

To maximize performance in multi-processor configurations, distribute the total memory capacity between all processors as evenly as possible.

Do not mix Unbuffered and Registered PC3 DIMMs.

Each channel supports up to two Unbuffered DIMMs.

If quad-rank DIMMs are installed for a processor, a maximum of two DIMMs can be installed on each channel for that processor.

If a channel contains quad-rank DIMMs, the quad-rank DIMM must be installed first on that channel.

DIMM speeds are supported as indicated in the following table.

Hardware options installation 43

Populated slots

(per channel)

Rank Speeds supported

(MHz)

1

1

Single- or dual-rank

Quad-rank

1333, 1066

1066

2 Single- or dual-rank 1066

3 Single- or dual-rank 800

Advanced ECC population guidelines

For Advanced ECC mode configurations, observe the following guidelines:

Observe the general DIMM slot population guidelines (on page 43 ).

DIMMs may be installed individually.

Single-processor Advanced ECC population order

For Advanced ECC mode configurations with a single processor, populate the DIMM slots in the following order:

RDIMM: Sequentially in alphabetical order (A through I)

UDIMM: A through F, sequentially in alphabetical order. Do not populate DIMM slots G through I.

Multi-processor Advanced ECC population order

For Advanced ECC mode configurations with multiple processors, populate the DIMM slots for each processor in the following order:

RDIMM: Sequentially in alphabetical order (A through I)

UDIMM: A through F, sequentially in alphabetical order. Do not populate DIMM slots G through I.

Lockstep Memory population guidelines

For Lockstep memory mode configurations, observe the following guidelines:

Observe the general DIMM slot population guidelines (on page 43 ).

Always install DIMMs in channels 1 and 2 for each installed processor.

Do not install DIMMs in channel 3 for any processor.

DIMM configuration on channel 1 and channel 2 of a processor must be identical.

In multi-processor configurations, each processor must have a valid Lockstep Memory configuration.

In multi-processor configurations, each processor may have a different valid Lockstep Memory configuration.

Single-processor Lockstep population order

For Lockstep memory mode configurations with a single processor, populate the DIMM slots in the following order:

RDIMM o

First: A and B

Hardware options installation 44

o o

Next: D and E

Last: G and H

Do not populate slots C, F, or I. o

UDIMM o

First: A and B o o

Last: D and E

Do not populate slots C, F, G, H, or I.

After installing the DIMMs, use RBSU to configure the system for Lockstep memory support (" Configuring lockstep memory " on page 87 ).

Multi-processor Lockstep population order

For Lockstep memory mode configurations with multiple processors, populate the DIMM slots for each processor in the following order:

RDIMM o o

First: A and B

Next: D and E o o

Last: G and H

Do not populate slots C, F, or I.

UDIMM o o

First: A and B

Last: D and E o

Do not populate slots C, F, G, H, or I.

After installing the DIMMs, use RBSU to configure the system for Lockstep memory support (" Configuring lockstep memory " on page 87 ).

Mirrored Memory population guidelines

For Mirrored Memory mode configurations, observe the following guidelines:

Observe the general DIMM slot population guidelines (on page 43 ).

Always install DIMMs in channels 1 and 2 for each installed processor.

Do not install DIMMs in channel 3 for any processor.

DIMMs installed on channel 1 and channel 2 of an installed processor must be identical.

In multi-processor configurations, each processor must have a valid Mirrored Memory configuration.

In multi-processor configurations, each processor may have a different valid Mirrored Memory configuration.

Single-processor Mirrored Memory population order

For Mirrored Memory mode configurations with a single processor, populate the DIMM slots in the following order:

RDIMM

Hardware options installation 45

o o

First: A and B

Next: D and E

Last: G and H o o

Do not populate slots C, F, or I.

UDIMM o o o

First: A and B

Last: D and E

Do not populate slots C, F, G, H, or I.

After installing the DIMMs, use RBSU to configure the system for Mirrored Memory support (" Configuring mirrored memory " on page 86 ).

Multi-processor Mirrored Memory population order

For Mirrored Memory mode configurations with multiple processors, populate the DIMM slots for each processor in the following order:

RDIMM o

First: A and B o o

Next: D and E

Last: G and H o

Do not populate slots C, F, or I.

UDIMM o

First: A and B o o

Last: D and E

Do not populate slots C, F, G, H, or I.

After installing the DIMMs, use RBSU to configure the system for mirrored memory support (" Configuring mirrored memory " on page 86 ).

Online Spare population guidelines

For Online Spare mode configurations, observe the following guidelines:

Observe the general DIMM slot population guidelines (on page 43 ).

DIMM configuration on each channel of a processor must be identical.

Each processor must have a valid Online Spare configuration.

In multi-processor configurations, each processor can have a different valid Online Spare configuration.

Single-processor Online Spare population order

For Online Spare mode configurations with a single processor, populate the DIMM slots in the following order:

RDIMM o

First: A, B, and C

Hardware options installation 46

o o

Next: D, E, and F

Last: G, H, and I

UDIMM o

First: A, B, and C o o

Last: D, E, and F

Do not populate slots G, H, and I.

After installing the DIMMs, use RBSU to configure the system for online spare memory support

(" Configuring online spare memory " on page 87 ).

Multi-processor Online Spare population order

For Online Spare mode configurations with a multiple processors, populate the DIMM slots for each processor in the following order:

RDIMM o

First: A, B, and C o o

Next: D, E, and F

Last: G, H, and I

UDIMM o

First: A, B, and C o o

Last: D, E, and F

Do not populate slots G, H, and I.

After installing the DIMMs, use RBSU to configure the system for online spare memory support

(" Configuring online spare memory " on page 87 ).

Installing DIMMs

CAUTION: To avoid damage to the hard drives, memory, and other system components, the air baffle, drive blanks, and access panel must be installed when the server is powered up.

1.

2.

3.

4.

5.

Power down the server (on page 20 ).

Do one of the following: o o

Open or remove the tower bezel, as needed (" Open or remove the tower bezel " on page 20 ).

Extend the server from the rack (on page 21 ).

Remove the access panel (on page 21 ).

Remove the air baffle (on page 22 ).

Open the DIMM slot latches.

Hardware options installation 47

6.

Install the DIMM.

7.

8.

9.

10.

Install the air baffle.

Install the access panel (on page 22 ).

Do one of the following: o

Close or install the tower bezel, as needed. o

Slide the server back into the rack.

Power up the server (on page 20 ).

After installing DIMMs, configure the AMP mode in RBSU (" HP ROM-Based Setup Utility " on page 85 ).

Redundant hot-plug power supply option

The server supports a second hot-plug power supply to provide redundant power to the system if the primary power supply fails.

WARNING: To reduce the risk of electric shock or damage to the equipment:

• Do not disable the power cord grounding plug. The grounding plug is an important safety feature.

• Plug the power cord into a grounded (earthed) electrical outlet that is easily accessible at all times.

Unplug the power cord from the power supply to disconnect power to the equipment.

Do not route the power cord where it can be walked on or pinched by items placed against it. Pay particular attention to the plug, electrical outlet, and the point where the cord extends from the equipment.

WARNING:

To reduce the risk of personal injury from hot surfaces, allow the power supply or power supply blank to cool before touching it.

WARNING:

To reduce the risk of electric shock or damage to the equipment, do not connect the power cord to the power supply until the power supply is installed.

Hardware options installation 48

CAUTION: Always install either a hot-plug power supply or a power supply blank into each bay to maintain proper airflow and cooling in the server. Improper airflow can lead to thermal damage.

Power supply configuration

Label color

CAUTION: All power supplies installed in the server must have the same output power capacity to operate in redundant mode. Verify that all power supplies have the same part number and label color. When the system detects mismatched power supplies, the system displays POST messages, does not power on the new power supply, and remains in nonredundant mode.

Output

Orange 750 W

Installing the redundant hot-plug power supply option

WARNING: To reduce the risk of personal injury or damage to the equipment, the installation of power supplies should be performed only by individuals who are qualified in servicing server equipment and trained to deal with products capable of producing hazardous energy levels.

WARNING:

To reduce the risk of personal injury from hot surfaces, observe the thermal labels on each power supply or module.

WARNING:

To reduce the risk of injury from electric shock hazards, do not open power supplies. Refer all maintenance, upgrades, and servicing to qualified personnel.

CAUTION: Electrostatic discharge (ESD) can damage electronic components. Be sure that you are properly grounded (earthed) before beginning any installation procedure.

To install the component:

1.

Identify the redundant power supply bay.

IMPORTANT:

Power supplies for the model shown are hot-pluggable. When using the redundant power supply option, it is not necessary to power down the server before removing or installing a power supply.

Hardware options installation 49

2.

Remove the power supply blank.

3.

WARNING: To reduce the risk of electric shock or damage to the equipment, do not connect

AC power cords to uninstalled power supplies.

Slide the power supply into the power supply bay until the release/lock lever clicks, securing the power supply.

4.

5.

6.

7.

Connect the power cord to the power supply.

Using the retaining clip shipped with the server, secure the power cord to the power supply handle.

Securing the cord will ensure enough slack.

Connect the power cord to the AC power source.

Be sure that the power supply LED is illuminated green (" Rear panel LEDs and buttons " on page 10 ).

Redundant fan assembly option

To install the component:

1.

2.

Power down the server (on page 20 ).

Do one of the following:

Hardware options installation 50

3.

4.

5. o o

Open or remove the tower bezel, as needed (" Open or remove the tower bezel " on page 20 ).

Extend the server from the rack (on page

Remove the access panel (on page 21 ).

21 ).

Remove the air baffle (on page 22 ).

Remove the fan from fan bay 1.5.

6.

7.

Install the removed fan in fan bay 2.

Install a fan from the option kit in fan bay 1.

8.

9.

10.

11.

Locate the fan 1 connector (" System board components " on page 11 ).

Remove the jumper from the fan 1 connector.

Connect the fan cables to the system board (" System board components " on page 11 ):

a. b.

Fan 1 cable to fan 1 connector

Fan 2 cable to fan 2 connector

Install the air baffle.

Hardware options installation 51

12.

13.

14.

Install the access panel (on page 22 ).

Do one of the following: o

Close or install the tower bezel, as needed. o

Slide the server back into the rack.

Power up the server (on page 20 ).

SAS or SATA hard drive option

CAUTION:

For proper cooling, do not operate the server without the access panel, baffles, expansion slot covers, hard drives, or blanks installed.

To install the component:

1.

Remove the hard drive blank.

2.

Prepare the drive for installation.

Hardware options installation 52

3.

Install the hard drive.

4.

5.

Determine the status of the drive by observing the drive LEDs (" Hot-plug SATA or SAS hard drive

LEDs " on page 18 ).

Resume normal server operations.

Expansion hard drive cage option (hot-plug)

To install the component:

1.

Power down the server (on page 20 ).

2.

Do one of the following: o

Open or remove the tower bezel, as needed (" Open or remove the tower bezel " on page 20 ).

3.

4. o

Extend the server from the rack (on page 21 ).

Remove the access panel (on page 21 ).

Remove the air baffle (on page 22 ).

Hardware options installation 53

5.

Using a T-15 Torx screwdriver, remove the hard drive cage blank.

6.

Install the expansion hard drive cage.

7.

Connect the following cables to the expansion hard drive cage. a.

SATA controller cable b. c.

Hard drive data cable

An available power cable

Hardware options installation 54

The server is not shown for clarity.

8.

9.

10.

Do one of the following: o

If using a SATA/SAS RAID controller, install the controller (" Installing expansion boards " on page 64 ).

o

If using SATA cables, connect the cables to the system board, and then proceed to step 10.

Connect the SATA controller cable to the RAID controller.

Connect the hard drive data cable to a hard drive backplane connector on the system board

(" System board components " on page 11 ).

CAUTION:

To prevent improper cooling and thermal damage, do not operate the server unless all bays are populated with either a component or a blank.

11.

12.

13.

14.

15.

Install any hard drives or blanks (" SAS or SATA hard drive option " on page 52 ).

Install the air baffle.

Install the access panel (on page 22 ).

Do one of the following: o o

Close or install the tower bezel, as needed.

Slide the server back into the rack.

Power up the server (on page 20 ).

Expansion hard drive cage option (non-hot-plug)

To install the component:

1.

2.

Power down the server (on page 20 ).

Do one of the following:

3. o o

Open or remove the tower bezel, as needed (" Open or remove the tower bezel " on page 20 ).

Extend the server from the rack (on page 21 ).

Remove the access panel (on page 21 ).

Hardware options installation 55

4.

5.

Remove the air baffle (on page 22 ).

Using a T-15 Torx screwdriver, remove the hard drive cage blank.

6.

7.

CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all bays are populated with either a component or a blank.

Using four of the surplus T-15 screws located on the non-hot-plug hard drive expansion cage, install the non-hot-plug hard drives.

Connect the power and data cables to the non-hot-plug hard drive.

8.

Install the non-hot-plug hard drive expansion cage.

Hardware options installation 56

Be sure to thread the cables through the rear of the non-hot-plug expansion cage into the server.

9.

10.

11.

12.

13.

Connect the cables to the SATA connectors 1-4 on the system board (" System board components " on page 11 ).

Install the air baffle.

Install the access panel (on page 22 ).

Do one of the following: o

Close or install the tower bezel, as needed. o

Slide the server back into the rack.

Power up the server (on page 20 ).

Removable media devices

This section provides the following information and procedures:

Identifying guide screws (on page 58 )

SATA optical drive option (on page 58 )

USB tape drive option (on page 60 )

Full-height tape drive option (on page 61 )

Hardware options installation 57

Identifying guide screws

When installing drives in the removable media bay, guide screws must be installed so that the drives align correctly in the drive cage. HP has provided extra guide screws, located behind the side access panel. Depending on the option, use 5.25 M3 metric screws or HD 6-32 shipping screws. The metric screws supplied by HP are black.

SATA optical drive option

For clarity, the following illustrations include option cabling only.

CAUTION:

To prevent improper cooling and thermal damage, do not operate the server unless all bays are populated with either a component or a blank.

To install the component:

1.

Power down the server (on page 20 ).

2.

3.

Do one of the following: o

Open or remove the tower bezel, as needed (" Open or remove the tower bezel " on page 20 ).

o

Extend the server from the rack (on page 21 ).

Remove the access panel (on page 21 ).

4.

5.

Remove the applicable media bay blank (" Remove the media bay blank " on page 23 ).

Identify the guide screws (" Identifying guide screws " on page 58 ).

Hardware options installation 58

6.

Install the guide screws on the optical drive.

7.

Install the optical drive.

8.

9.

Connect the power cable to the rear of the drive.

Connect the optical drive cable to the rear of the optical drive and to the SATA connector on the system board.

Hardware options installation 59

10.

11.

12.

13.

Remove the applicable bezel blank from the bezel (" Remove a bezel blank " on page 24 ).

Install the access panel (on page 22 ).

Do one of the following: o o

Close or install the tower bezel, as needed.

Slide the server back into the rack.

Power up the server (on page 20 ).

USB tape drive option

For clarity, the following illustrations include option cabling only.

CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all bays are populated with either a component or a blank.

To install the component:

1.

Power down the server (on page 20 ).

2.

Do one of the following: o

Open or remove the tower bezel, as needed (" Open or remove the tower bezel " on page 20 ).

3.

4.

5.

6. o

Extend the server from the rack (on page 21 ).

Remove the access panel (on page 21 ).

Remove the applicable media bay blank (" Remove the media bay blank " on page 23 ).

Identify the guide screws (" Identifying guide screws " on page 58 ).

Install the guide screws.

Hardware options installation 60

7.

Install the tape drive.

8.

9.

Connect the power cable to the rear of the drive.

Connect the USB tape drive cable to the rear of the drive and to the USB tape drive connector on the system board.

10.

11.

12.

13.

Remove the applicable bezel blank from the bezel (" Remove a bezel blank " on page 24 ).

Install the access panel (on page 22 ).

Do one of the following: o o

Close or install the tower bezel, as needed.

Slide the server back into the rack.

Power up the server (on page 20 ).

Full-height tape drive option

For clarity, the following illustrations include option cabling only.

Hardware options installation 61

To install the component:

1.

Power down the server (on page 20 ).

2.

Do one of the following:

3.

4. o o

Unlock and remove the bezel (" Open or remove the tower bezel " on page 20 ).

Extend the server from the rack (on page

Remove the access panel (on page 21 ).

21 ).

Remove the applicable media bay blanks (" Remove the media bay blank " on page 23 ).

IMPORTANT: For correct cabling, install the full-height tape drive in the top two slots.

5.

6.

Identify the guide screws (" Identifying guide screws " on page 58 ).

Install the guide screws.

7.

Install the tape drive.

8.

9.

Install a SAS controller (" Installing expansion boards " on page 64 ).

Connect the power cable to the rear of the drive.

Hardware options installation 62

10.

Connect the tape drive cable to the rear of the drive and to the SAS controller.

11.

12.

13.

14.

Remove the applicable bezel blanks from the bezel (" Remove a bezel blank " on page 24 ).

Install the access panel (on page 22 ).

Do one of the following: o o

Close or install the tower bezel, as needed.

Slide the server back into the rack.

Power up the server (on page 20 ).

Expansion board options

3

4

1

2

5

6

The server supports PCI Express and PCI-X expansion boards. Slot 1 is located on the optional PCI-X

extender board (" PCI-X extender board option " on page 65 ).

Slot Expansion board type

Connector Maximum speed

PCI-X (optional)

PCI-X (optional)

PCIe1

PCIe2

PCIe2

PCIe2

64 bit, 3.3 V

64 bit, 3.3 V x8 x16 x8 x8

100 MHz

100 MHz x1 x16 x4 x4

Removing the expansion slot cover

1.

2.

Power down the server (on page 20 ).

Do one of the following: o o

Open or remove the tower bezel, as needed (" Open or remove the tower bezel " on page 20 ).

Extend the server from the rack (on page 21 ).

Hardware options installation 63

3.

4.

Remove the access panel (on page 21 ).

Open the slot cover retainer.

5.

Remove the slot cover.

CAUTION:

To prevent improper cooling and thermal damage, do not operate the server unless all PCI slots have either an expansion slot cover or an expansion board installed.

Installing expansion boards

CAUTION:

To prevent damage to the server or expansion boards, power down the server and remove all AC power cords before removing or installing the expansion boards.

1.

2.

Power down the server (on page 20 ).

Do one of the following: o

Open or remove the tower bezel, as needed (" Open or remove the tower bezel " on page 20 ).

Hardware options installation 64

3.

4.

5. o

Extend the server from the rack (on page 21 ).

Remove the access panel (on page 21 ).

Remove the expansion slot cover (" Removing the expansion slot cover " on page 63 ).

Install the expansion board, and then press firmly to seat the board in the connector.

6.

7.

8.

9.

10.

11.

Close the slot cover retainer.

Connect any required internal cables to the expansion board. See the documentation that ships with the expansion board.

Install the access panel (on page 22 ).

Do one of the following: o o

Close or install the tower bezel, as needed.

Slide the server back into the rack.

Connect any required external cables.

Power up the server (on page 20 ).

PCI-X extender board option

1.

2.

3.

4.

5.

6.

Power down the server (on page 20 ).

Disconnect power cords from the power source.

Disconnect all power cords from the server.

Do one of the following: o

Open or remove the tower bezel, as needed (" Open or remove the tower bezel " on page 20 ).

o

Extend the server from the rack (on page 21 ).

Remove the access panel (on page 21 ).

Remove the air baffle (on page 22 ).

Hardware options installation 65

7.

Remove the protective film from the PCI-X expansion cage bracket.

8.

9.

Disconnect the power cable from the extender board.

Using a T-10 Torx screwdriver, remove the six screws securing the extender board, and then remove the extender board from the PCI-X expansion cage bracket.

10.

11.

Remove fan 3.

Install the extender board.

Hardware options installation 66

12.

Connect the power extender cables, provided in the option kit, to the power cables in the server.

For clarity, the following illustration includes cabling only.

13.

14.

Install the riser board in expansion slot 5.

Connect the mini-SAS data cable to the extender board and to the riser board.

15.

16.

17.

18.

(Optional) Install expansion boards in the extender board (" Installing expansion boards " on page

64 ).

Install fan 3.

Install the air baffle.

Install the access panel (on page 22 ).

Hardware options installation 67

19.

20.

21.

22.

Do one of the following: o

Close or install the tower bezel, as needed. o

Slide the server back into the rack.

Connect all power cords to the server.

Connect power cords to the power source.

Power up the server (on page 20 ).

Storage controller option

IMPORTANT: For additional installation and configuration information, refer to the documentation that ships with the option.

To install the component:

1.

Power down the server (on page 20 ).

2.

Do one of the following:

3.

4.

5.

6.

7.

8.

9.

10. o o

Open or remove the tower bezel, as needed (" Open or remove the tower bezel " on page 20 ).

Extend the server from the rack (on page

Remove the access panel (on page 21 ).

21 ).

Remove the air baffle (on page 22 ).

Install the storage controller (" Installing expansion boards " on page 64 ).

Connect the mini-SAS to mini-SAS cable, provided in the mini-SAS to mini-SAS cable option kit, to the hard drive backplane and to the storage controller.

Install the air baffle.

Install the access panel (on page 22 ).

Do one of the following: o

Close or install the tower bezel, as needed. o

Slide the server back into the rack.

Power up the server (on page 20 ).

Battery-backed write cache battery pack option

CAUTION: To prevent a server malfunction or damage to the equipment, do not add or remove the battery pack while an array capacity expansion, RAID level migration, or stripe size migration is in progress.

CAUTION: After the server is powered down, wait 15 seconds and then check the amber LED before unplugging the cable from the cache module. If the amber LED blinks after 15 seconds, do not remove the cable from the cache module. The cache module is backing up data, and data is lost if the cable is detached.

Hardware options installation 68

IMPORTANT: The battery pack might have a low charge when installed. In this case, a POST error message is displayed when the server is powered up, indicating that the battery pack is temporarily disabled. No action is necessary on your part. The internal circuitry automatically recharges the batteries and enables the battery pack. This process might take up to four hours. During this time, the cache module functions properly, but without the performance advantage of the battery pack.

NOTE: The data protection and the time limit also apply if a power outage occurs. When power is restored to the system, an initialization process writes the preserved data to the hard drives.

To install the component:

1.

2.

Power down the server (on page 20 ).

Do one of the following:

3.

4.

5.

6. o o

Open or remove the tower bezel, as needed (" Open or remove the tower bezel " on page 20 ).

Extend the server from the rack (on page 21 ).

Remove the access panel (on page 21 ).

Install the storage controller, if not installed (" Installing expansion boards " on page 64 ).

Open the cache module latches.

Install the cache module on the controller.

Hardware options installation 69

7.

Connect the cable to the cache module.

8.

Install the battery pack.

9.

10.

11.

12.

Route the cable.

Install the access panel (on page 22 ).

Do one of the following: o

Close or install the tower bezel, as needed. o

Slide the server back into the rack.

Power up the server (on page 20 ).

FBWC module and capacitor pack option

CAUTION: Do not use this controller with cache modules designed for other controller models, because the controller can malfunction and you can lose data. Also, do not transfer this cache module to a different controller module, because you can lose data.

Hardware options installation 70

To install the component:

1.

Back up all data.

2.

3.

Close all applications.

Power down the server (on page 20 ).

CAUTION: In systems that use external data storage, be sure that the server is the first unit to be powered down and the last to be powered back up. Taking this precaution ensures that the system does not erroneously mark the drives as failed when the server is powered up.

4.

5.

6.

Do one of the following: o

Open or remove the tower bezel, as needed (" Open or remove the tower bezel " on page 20 ).

o

Extend the server from the rack (on page 21 ).

Remove the access panel (on page 21 ).

Install the FBWC module.

7.

Connect the cable.

Hardware options installation 71

8.

Install the capacitor pack.

9.

10.

11.

12.

Route the cable.

Install the access panel (on page 22 ).

Do one of the following: o

Close or install the tower bezel, as needed. o

Slide the server back into the rack.

Power up the server (on page 20 ).

SAS controller option

To install the component:

1.

Power down the server (on page 20 ).

2.

Do one of the following: o

Open or remove the tower bezel, as needed (" Open or remove the tower bezel " on page 20 ).

3.

4.

5.

6.

7.

8.

9.

10. o

Extend the server from the rack (on page 21 ).

Remove the access panel (on page 21 ).

Remove the expansion slot cover (" Removing the expansion slot cover " on page 63 ).

Install the SAS controller (" Installing expansion boards " on page 64 ).

Disconnect the SATA cable from the hard drive backplane and from the system board.

Connect the SAS cable to the hard drive backplane and to the SAS controller.

Install the access panel (on page 22 ).

Do one of the following: o

Close or install the tower bezel, as needed. o

Slide the server back into the rack.

Power up the server (on page 20 ).

Hardware options installation 72

Dedicated iLO 2 port module option

To install the component:

1.

2.

Power down the server (on page 20 ).

Do one of the following:

3.

4. o o

Open or remove the tower bezel, as needed (" Open or remove the tower bezel " on page 20 ).

Extend the server from the rack (on page 21 ).

Remove the access panel (on page 21 ).

Using a Phillips screwdriver, remove the dedicated iLO 2 connector module blank.

5.

Install the dedicated iLO 2 management port module.

Hardware options installation 73

6.

Using a T-15 Torx screwdriver, secure the dedicated iLO 2 management port module.

7.

8.

9.

10.

Install the access panel.

Do one of the following: o

Close or install the tower bezel, as needed. o

Slide the server back into the rack.

Connect a network cable to the module, as needed.

Power up the server (on page 20 ).

HP Trusted Platform Module option

Use these instructions to install and enable a TPM on a supported server. This procedure includes three sections:

1.

Installing the Trusted Platform Module board (on page 75 ).

2.

3.

Retaining the recovery key/password (on page 76 ).

Enabling the Trusted Platform Module (on page 77 ).

Enabling the TPM requires accessing the ROM-Based Setup Utility (RBSU) (" HP ROM-Based Setup

Utility " on page 85 ). For more information about RBSU, see the HP website

( http://www.hp.com/support/smartstart/documentation ).

TPM installation requires the use of drive encryption technology, such as the Microsoft® Windows®

BitLocker™ Drive Encryption feature. For more information on BitLocker™, see the Microsoft website

( http://www.microsoft.com

).

CAUTION: Always observe the guidelines in this document. Failure to follow these guidelines can cause hardware damage or halt data access.

When installing or replacing a TPM, observe the following guidelines:

Do not remove an installed TPM. Once installed, the TPM becomes a permanent part of the system board.

Hardware options installation 74

When installing or replacing hardware, HP service providers cannot enable the TPM or the encryption technology. For security reasons, only the customer can enable these features.

When returning a system board for service replacement, do not remove the TPM from the system board. When requested, HP Service provides a TPM with the spare system board.

Any attempt to remove an installed TPM from the system board breaks or disfigures the TPM security rivet. Upon locating a broken or disfigured rivet on an installed TPM, administrators should consider the system compromised and take appropriate measures to ensure the integrity of the system data.

When using BitLocker™, always retain the recovery key/password. The recovery key/password is required to enter Recovery Mode after BitLocker™ detects a possible compromise of system integrity.

HP is not liable for blocked data access caused by improper TPM use. For operating instructions, see the encryption technology feature documentation provided by the operating system.

Installing the Trusted Platform Module board

WARNING: To reduce the risk of personal injury, electric shock, or damage to the equipment, remove the power cord to remove power from the server. The front panel Power

On/Standby button does not completely shut off system power. Portions of the power supply and some internal circuitry remain active until AC power is removed.

WARNING:

To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system components to cool before touching them.

1.

2.

3.

4.

Power down the server (on page 20 ).

Do one of the following: o

Open or remove the tower bezel, as needed (" Open or remove the tower bezel " on page 20 ).

o

Extend the server from the rack (on page 21 ).

Remove the access panel (on page 21 ).

Remove the air baffle (on page 22 ).

IMPORTANT: When removing a processor board to install a TPM, the processor, heatsink, and DIMMs can remain installed on the processor board.

5.

6.

Remove the processor board, if necessary (" Remove the processor board " on page 24 ).

Locate the TPM connector (" System board components " on page 11 ).

CAUTION: Any attempt to remove an installed TPM from the system board breaks or disfigures the TPM security rivet. Upon locating a broken or disfigured rivet on an installed

TPM, administrators should consider the system compromised and take appropriate measures to ensure the integrity of the system data.

Hardware options installation 75

7.

Install the TPM board. Press down on the connector to seat the board (" System board components " on page 11 ).

8.

Install the TPM security rivet by pressing the rivet firmly into the system board.

9.

10.

11.

12.

13.

Install the processor board, if removed (" Install the processor board " on page 25 ).

Install the air baffle.

Install the access panel (on page 22 ).

Do one of the following: o

Close or install the tower bezel, as needed. o

Slide the server back into the rack.

Power up the server (on page 20 ).

Retaining the recovery key/password

The recovery key/password is generated during BitLocker™ setup, and can be saved and printed after

BitLocker™ is enabled. When using BitLocker™, always retain the recovery key/password. The recovery

Hardware options installation 76

key/password is required to enter Recovery Mode after BitLocker™ detects a possible compromise of system integrity.

To help ensure maximum security, observe the following guidelines when retaining the recovery key/password:

Always store the recovery key/password in multiple locations.

Always store copies of the recovery key/password away from the server.

Do not save the recovery key/password on the encrypted hard drive.

Enabling the Trusted Platform Module

1.

2.

3.

4.

5.

6.

7.

8.

When prompted during the start-up sequence, access RBSU by pressing the F9 key.

From the Main Menu, select Server Security.

From the Server Security Menu, select Trusted Platform Module.

From the Trusted Platform Module Menu, select TPM Functionality.

Select Enable, and then press the Enter key to modify the TPM Functionality setting.

Press the Esc key to exit the current menu, or press the F10 key to exit RBSU.

Reboot the server.

Enable the TPM in the OS. For OS-specific instructions, see the OS documentation.

CAUTION: When a TPM is installed and enabled on the server, data access is locked if you fail to follow the proper procedures for updating the system or option firmware, replacing the system board, replacing a hard drive, or modifying OS application TPM settings.

For more information on firmware updates and hardware procedures, see the HP Trusted Platform Module

Best Practices White Paper on the HP website ( http://www.hp.com/support ).

For more information on adjusting TPM usage in BitLocker™, see the Microsoft website

( http://technet.microsoft.com/en-us/windowsvista/aa905065.aspx

).

Hardware options installation 77

Cabling

Non-hot-plug SATA hard drive cabling

Item

3

4

1

2

5

Description

Media bay 11

Media bay 10

Media bay 9

Hard drive bay (hard drives 1-4)

Hard drive bay (hard drives 5-8)

Cabling 78

Non-hot-plug SATA/SAS hard drive cabling

Description

Media bay 11

Media bay 10

Media bay 9

Hard drive bay (hard drives 1-4)

Item

3

4

1

2

Hot-plug SATA/SAS hard drive cabling

Item

1

2

Description

Media bay 11

Media bay 10

Cabling 79

Item

3

4

Description

Media bay 9

Hard drive bay (hard drives 1-4)

Non-hot-plug hard drive single power cabling

3

4

1

2

5

6

7

The hard drive backplane uses the 4-pin power connectors.

When connecting SATA hard drives, be sure to use the black SATA power connectors.

Item Description

Media bay 11

Media bay 10

Hard drive bay (hard drives 1-4)

Power supply

4-pin power connector (P14)

4-pin power connector (P2)

24-pin power connector

Cabling 80

Hot-plug hard drive single power cabling

The hard drive backplane uses the 4-pin power connectors.

5

6

7

3

4

1

2

When connecting SATA hard drives, be sure to use the black SATA power connectors.

Item Description

Media bay 11

Media bay 10

Hard drive bay (hard drives 1-4)

Power supply

4-pin power connector (P14)

4-pin power connector (P2)

24-pin power connector

Cabling 81

Non-hot-plug hard drive redundant power cabling

The hard drive backplane uses the 4-pin power connectors.

When connecting SATA hard drives, be sure to use the black SATA power connectors.

Item Description

7

8

9

5

6

10

11

3

4

1

2

Media bay 11

Media bay 10

Media bay 9

Hard drive bay (hard drives 1-4)

Hard drive bay (hard drives 5-8)

Power supply

4-pin power connector (P19)

16-pin power connector

4-pin power connector (P3)

8-pin power connector

24-pin power connector

Cabling 82

Hot-plug hard drive redundant power cabling

8

9

10

11

1

2

3

4

5

6

7

The hard drive backplane uses the 4-pin power connectors.

When connecting SATA hard drives, be sure to use the black SATA power connectors.

Item Description

Media bay 11

Media bay 10

Media bay 9

Hard drive bay (hard drives 1-4)

Hard drive bay (hard drives 5-8)

Power supply

4-pin power connector (P19)

16-pin power connector

4-pin power connector (P3)

8-pin power connector

24-pin power connector

Cabling 83

Configuration and utilities

Configuration tools

SmartStart software

SmartStart is a collection of software that optimizes single-server setup, providing a simple and consistent way to deploy server configuration. SmartStart has been tested on many ProLiant server products, resulting in proven, reliable configurations.

SmartStart assists the deployment process by performing a wide range of configuration activities, including:

Preparing the system for installing "off-the-shelf" versions of leading operating system software

Installing optimized server drivers, management agents, and utilities automatically with every assisted installation

Testing server hardware using the Insight Diagnostics Utility (" HP Insight Diagnostics " on page 91 )

Installing software drivers directly from the CD. With systems that have Internet connection, the

SmartStart Autorun Menu provides access to a complete list of ProLiant system software.

Enabling access to the Array Configuration Utility and Erase Utility (on page 89 )

SmartStart is included in the HP Insight Foundation suite for ProLiant. For more information about

SmartStart software, see the HP Insight Foundation suite for ProLiant or the HP website

( http://www.hp.com/go/foundation ).

SmartStart Scripting Toolkit

The SmartStart Scripting Toolkit is a server deployment product that delivers an unattended automated installation for high-volume server deployments. The SmartStart Scripting Toolkit is designed to support

ProLiant BL, ML, DL, and 100 series servers. The toolkit includes a modular set of utilities and important documentation that describes how to apply these new tools to build an automated server deployment process.

Using SmartStart technology, the Scripting Toolkit provides a flexible way to create standard server configuration scripts. These scripts are used to automate many of the manual steps in the server configuration process. This automated server configuration process cuts time from each deployment, making it possible to scale server deployments to high volumes in a rapid manner.

For more information, and to download the SmartStart Scripting Toolkit, see the HP website

( http://www.hp.com/servers/sstoolkit ).

Configuration Replication Utility

CONREP is shipped in the SmartStart Scripting Toolkit and is a program that works with RBSU to replicate hardware configuration on ProLiant servers. This utility is run during State 0, Run Hardware Configuration

Utility, when doing a scripted server deployment. CONREP reads the state of the system environment

Configuration and utilities 84

variables to determine the configuration and then writes the results to an editable script file. This file can then be deployed across multiple servers with similar hardware and software components. For more information, refer to the SmartStart Scripting Toolkit User Guide on the HP website

( http://h18004.www1.hp.com/products/servers/management/toolkit/documentation.html

).

HP ROM-Based Setup Utility

RBSU is a configuration utility embedded in ProLiant servers that performs a wide range of configuration activities that can include the following:

Configuring system devices and installed options

Enabling and disabling system features

Displaying system information

Selecting the primary boot controller

Configuring memory options

Language selection

For more information on RBSU, see the HP ROM-Based Setup Utility User Guide on the Documentation CD or the HP website ( http://www.hp.com/support/smartstart/documentation ).

Using RBSU

To use RBSU, use the following keys:

To access RBSU, press the F9 key during power-up when prompted.

To navigate the menu system, use the arrow keys.

To make selections, press the Enter key.

To access Help for a highlighted configuration option, press the F1 key.

IMPORTANT:

RBSU automatically saves settings when you press the Enter key. The utility does not prompt you for confirmation of settings before you exit the utility. To change a selected setting, you must select a different setting and press the Enter key.

Default configuration settings are applied to the server at one of the following times:

Upon the first system power-up

After defaults have been restored

Default configuration settings are sufficient for proper typical server operation, but configuration settings can be modified using RBSU. The system will prompt you for access to RBSU with each power-up.

Auto-configuration process

The auto-configuration process automatically runs when you boot the server for the first time. During the power-up sequence, the system ROM automatically configures the entire system without needing any intervention. During this process, the ORCA utility, in most cases, automatically configures the array to a default setting based on the number of drives connected to the server.

NOTE: The server may not support all the following examples.

Configuration and utilities 85

NOTE: If the boot drive is not empty or has been written to in the past, ORCA does not automatically configure the array. You must run ORCA to configure the array settings.

Drives installed Drives used RAID level

1

2

3, 4, 5, or 6

More than 6

1

2

3, 4, 5, or 6

0

RAID 0

RAID 1

RAID 5

None

To change any ORCA default settings and override the auto-configuration process, press the F8 key when prompted.

By default, the auto-configuration process configures the system for the English language. To change any default settings in the auto-configuration process (such as the settings for language, operating system, and primary boot controller), execute RBSU by pressing the F9 key when prompted. After the settings are selected, exit RBSU and allow the server to reboot automatically.

For more information on RBSU, see the HP ROM-Based Setup Utility User Guide on the Documentation CD or the HP website ( http://www.hp.com/support/smartstart/documentation ).

Boot options

Near the end of the boot process, the boot options screen is displayed. This screen is visible for several seconds before the system attempts to boot from a supported boot device. During this time, you can do the following:

Access RBSU by pressing the F9 key.

Access the System Maintenance Menu (which enables you to launch ROM-based Diagnostics or

Inspect) by pressing the F10 key.

Force a PXE Network boot by pressing the F12 key.

BIOS Serial Console

BIOS Serial Console allows you to configure the serial port to view POST error messages and run RBSU remotely through a serial connection to the server COM port. The server that you are remotely configuring does not require a keyboard and mouse.

For more information about BIOS Serial Console, see the BIOS Serial Console User Guide on the

Documentation CD or the HP website ( http://www.hp.com/support/smartstart/documentation ).

Configuring mirrored memory

To configure mirrored memory:

1.

2.

3.

Install the required DIMMs (" Installing DIMMs " on page 47 ).

Access RBSU by pressing the F9 key during power-up when the prompt is displayed.

Select System Options.

4.

5.

6.

Select Advanced Memory Protection.

Select Mirrored Memory with Advanced ECC Support.

Press the Enter key.

Configuration and utilities 86

7.

Press the Esc key to exit the current menu or press the F10 key to exit RBSU.

For more information on mirrored memory, see the white paper on the HP website

( http://h18000.www1.hp.com/products/servers/technology/memoryprotection.html

).

Configuring lockstep memory

To configure Lockstep memory:

1.

Install the required DIMMs (" Installing DIMMs " on page 47 ).

2.

3.

Access RBSU by pressing the F9 key during power-up when the prompt is displayed.

Select System Options.

4.

5.

6.

7.

Select Advanced Memory Protection.

Select Lockstep with Advanced ECC Support.

Press the Enter key.

Press the Esc key to exit the current menu, or press the F10 key to exit RBSU.

For more information on Lockstep memory, see the white paper on the HP website

( http://h18000.www1.hp.com/products/servers/technology/memoryprotection.html

).

Configuring online spare memory

To configure online spare memory:

1.

Install the required DIMMs (" Installing DIMMs " on page 47 ).

2.

3.

When the prompt appears, access RBSU by pressing the F9 key during power-up.

Select System Options.

4.

5.

6.

7.

Select Advanced Memory Protection.

Select Online Spare with Advanced ECC Support.

Press the Enter key.

Press the Esc key to exit the current menu, or press the F10 key to exit RBSU.

For more information on online spare memory, see the HP website

( http://h18000.www1.hp.com/products/servers/technology/memoryprotection.html

).

Option ROM Configuration for Arrays

Before installing an operating system, you can use the ORCA utility to create the first logical drive, assign

RAID levels, and establish online spare configurations.

The utility also provides support for the following functions:

Reconfiguring one or more logical drives

Viewing the current logical drive configuration

Deleting a logical drive configuration

Setting the controller to be the boot controller

If you do not use the utility, ORCA will default to the standard configuration.

For more information regarding array controller configuration, refer to the controller user guide.

Configuration and utilities 87

For more information regarding the default configurations that ORCA uses, refer to the HP ROM-Based

Setup Utility User Guide on the Documentation CD.

HP ProLiant Essentials Rapid Deployment Pack

The RDP software is the preferred method for rapid, high-volume server deployments. The RDP software integrates two powerful products: Altiris Deployment Solution and the HP ProLiant Integration Module.

The intuitive graphical user interface of the Altiris Deployment Solution console provides simplified pointand-click and drag-and-drop operations that enable you to deploy target servers, including server blades, remotely. It enables you to perform imaging or scripting functions and maintain software images.

For more information about the RDP, refer to the HP ProLiant Essentials Rapid Deployment Pack CD or refer to the HP website ( http://www.hp.com/servers/rdp ).

Re-entering the server serial number and product ID

After you replace the system board, you must re-enter the server serial number and the product ID.

1.

During the server startup sequence, press the F9 key to access RBSU.

2.

3.

4.

5.

6.

7.

8.

Select the Advanced Options menu.

Select Service Options.

Select Serial Number. The following warnings appear:

WARNING! WARNING! WARNING! The serial number is loaded into the system during the manufacturing process and should NOT be modified. This option should only be used by qualified service personnel. This value should always match the serial number sticker located on the chassis.

Warning: The serial number should ONLY be modified by qualified personnel. This value should always match the serial number located on the chassis.

Press the Enter key to clear the warning.

Enter the serial number and press the Enter key.

Select Product ID. The following warning appears:

Warning: The Product ID should ONLY be modified by qualified personnel.

This value should always match the Product ID on the chassis.

Enter the product ID and press the Enter key.

9.

10.

11.

Press the Esc key to close the menu.

Press the Esc key to exit RBSU.

Press the F10 key to confirm exiting RBSU. The server automatically reboots.

Management tools

Automatic Server Recovery

ASR is a feature that causes the system to restart when a catastrophic operating system error occurs, such as a blue screen, ABEND, or panic. A system fail-safe timer, the ASR timer, starts when the System

Management driver, also known as the Health Driver, is loaded. When the operating system is

Configuration and utilities 88

functioning properly, the system periodically resets the timer. However, when the operating system fails, the timer expires and restarts the server.

ASR increases server availability by restarting the server within a specified time after a system hang or shutdown. At the same time, the HP SIM console notifies you by sending a message to a designated pager number that ASR has restarted the system. You can disable ASR from the HP SIM console or through RBSU.

ROMPaq utility

The ROMPaq utility enables you to upgrade the system firmware (BIOS). To upgrade the firmware, insert a ROMPaq USB Key into an available USB port and boot the system. In addition to ROMPaq, Online

Flash Components for Windows and Linux operating systems are available for updating the system firmware.

The ROMPaq utility checks the system and provides a choice (if more than one exists) of available firmware revisions.

For more information, see the Download drivers and software page for the server. To access the serverspecific page, enter the following web address into the browser: http://www.hp.com/support/<servername>

For example: http://www.hp.com/support/dl360g6

iLO 2 technology

The iLO 2 subsystem is a standard component of selected ProLiant servers that provides server health and remote server manageability. The iLO 2 subsystem includes an intelligent microprocessor, secure memory, and a dedicated network interface. This design makes iLO 2 independent of the host server and its operating system. The iLO 2 subsystem provides remote access to any authorized network client, sends alerts, and provides other server management functions.

Using iLO 2, you can:

Remotely power up, power down, or reboot the host server.

Send alerts from iLO 2 regardless of the state of the host server.

Access advanced troubleshooting features through the iLO 2 interface.

Diagnose iLO 2 using HP SIM through a web browser and SNMP alerting.

For more information about iLO 2 features (which may require an iLO Advanced Pack or iLO Advanced for BladeSystem license), see the iLO 2 documentation on the Documentation CD or on the HP website

( http://www.hp.com/servers/lights-out ).

Erase Utility

CAUTION:

Perform a backup before running the System Erase Utility. The utility sets the system to its original factory state, deletes the current hardware configuration information, including array setup and disk partitioning, and erases all connected hard drives completely.

Refer to the instructions for using this utility.

Configuration and utilities 89

Run the Erase Utility if you must erase the system for the following reasons:

You want to install a new operating system on a server with an existing operating system.

You encounter an error when completing the steps of a factory-installed operating system installation.

To access the Erase Utility, use the System Erase button on the home screen of the SmartStart CD

(" SmartStart software " on page 84 ).

StorageWorks library and tape tools

HP StorageWorks L&TT provides functionality for firmware downloads, verification of device operation, maintenance procedures, failure analysis, corrective service actions, and some utility functions. It also provides seamless integration with HP hardware support by generating and emailing support tickets that deliver a snapshot of the storage system.

For more information, and to download the utility, refer to the StorageWorks L&TT website

( http://h18006.www1.hp.com/products/storageworks/ltt ).

HP Systems Insight Manager

HP SIM is a web-based application that allows system administrators to accomplish normal administrative tasks from any remote location, using a web browser. HP SIM provides device management capabilities that consolidate and integrate management data from HP and third-party devices.

IMPORTANT:

You must install and use HP SIM to benefit from the Pre-Failure Warranty for processors, SAS and SATA hard drives, and memory modules.

For additional information, refer to the Management CD in the HP ProLiant Essentials Foundation Pack or the HP SIM website ( http://www.hp.com/go/hpsim ).

Management Agents

Management Agents provide the information to enable fault, performance, and configuration management. The agents allow easy manageability of the server through HP SIM software, and thirdparty SNMP management platforms. Management Agents are installed with every SmartStart assisted installation or can be installed through the HP PSP. The Systems Management homepage provides status and direct access to in-depth subsystem information by accessing data reported through the Management

Agents. For additional information, refer to the Management CD in the HP ProLiant Essentials Foundation

Pack or the HP website ( http://www.hp.com/servers/manage ).

Redundant ROM support

The server enables you to upgrade or configure the ROM safely with redundant ROM support. The server has a 8-MB ROM that acts as two, separate 4-MB ROMs. In the standard implementation, one side of the

ROM contains the current ROM program version, while the other side of the ROM contains a backup version.

NOTE: The server ships with the same version programmed on each side of the ROM.

Configuration and utilities 90

Safety and security benefits

When you flash the system ROM, ROMPaq writes over the backup ROM and saves the current ROM as a backup, enabling you to switch easily to the alternate ROM version if the new ROM becomes corrupted for any reason. This feature protects the existing ROM version, even if you experience a power failure while flashing the ROM.

USB support

HP provides both standard USB 2.0 support and legacy USB 2.0 support. Standard support is provided by the OS through the appropriate USB device drivers. Before the OS loads, HP provides support for USB devices through legacy USB support, which is enabled by default in the system ROM.

Legacy USB support provides USB functionality in environments where USB support is not available normally. Specifically, HP provides legacy USB functionality for the following:

POST

RBSU

Diagnostics

DOS

Operating environments which do not provide native USB support

Internal USB functionality

An internal USB connector is available for use with USB drive keys only. This solution provides for use of a permanent boot drive from a USB drive key installed in the internal connector, avoiding issues of clearance on the front of the rack and physical access to secure data.

For additional security, you can disable the external USB connectors through RBSU. Disabling the rear

USB connectors in RBSU disables both rear USB ports.

Diagnostic tools

HP Insight Diagnostics

HP Insight Diagnostics is a proactive server management tool, available in both offline and online versions, that provides diagnostics and troubleshooting capabilities to assist IT administrators who verify server installations, troubleshoot problems, and perform repair validation.

HP Insight Diagnostics Offline Edition performs various in-depth system and component testing while the

OS is not running. To run this utility, launch the SmartStart CD.

HP Insight Diagnostics Online Edition is a web-based application that captures system configuration and other related data needed for effective server management. Available in Microsoft® Windows® and

Linux versions, the utility helps to ensure proper system operation.

For more information or to download the utility, refer to the HP website

( http://www.hp.com/servers/diags ).

Configuration and utilities 91

HP Insight Diagnostics survey functionality

HP Insight Diagnostics (on page 91 ) provides survey functionality that gathers critical hardware and

software information on ProLiant servers.

This functionality supports operating systems that may not be supported by the server. For operating systems supported by the server, see the HP website ( http://www.hp.com/go/supportos ).

If a significant change occurs between data-gathering intervals, the survey function marks the previous information and overwrites the survey data files to reflect the latest changes in the configuration.

Survey functionality is installed with every SmartStart-assisted HP Insight Diagnostics installation, or it can

be installed through the HP PSP (" ProLiant Support Packs " on page 94 ).

NOTE: The current version of SmartStart provides the memory spare part numbers for the server. To download the latest version, see the HP website ( http://www.hp.com/support ).

Integrated Management Log

The IML records hundreds of events and stores them in an easy-to-view form. The IML timestamps each event with 1-minute granularity.

You can view recorded events in the IML in several ways, including the following:

From within HP SIM (" HP Systems Insight Manager " on page 90 )

From within Survey Utility

From within operating system-specific IML viewers o o

For NetWare: IML Viewer

For Windows®: IML Viewer

For Linux: IML Viewer Application o

From within the iLO 2 user interface

From within HP Insight Diagnostics (on page 91 )

For more information, see the Management CD in the HP Insight Foundation suite for ProLiant.

Array Diagnostic Utility

The HP Array Diagnostics Utility is a web-based application that creates a report of all HP storage controllers and disk drives. This report provides vital information to assist in identifying faults or conditions

that may require attention. ADU can be accessed from the SmartStart CD (" SmartStart software " on page

84 ) or downloaded from the HP website (

http://www.hp.com

).

HP Insight Server Migration software for ProLiant

The HP Insight Server Migration software for ProLiant (SMP) enables administrators to upgrade or replace an existing server through server migration. SMP provides an automated, accurate, and affordable method of migrating existing servers and their content to the latest server technologies.

SMP automates the migration of the operating system, applications, and data from one server to another without errors, eliminating the need for manual redeployment of these elements on the new server. During

Configuration and utilities 92

the migration process, the software automatically loads new drivers, required for boot, on the destination server. The wizard-based user interface simplifies the migration process and requires little experience or training.

For more information about the SMP, see the HP website ( http://www.hp.com/go/migrate ).

Remote support and analysis tools

HP Insight Remote Support software

HP Insight Remote Support software delivers secure remote support for your HP Servers and Storage, 24 X

7, so you can spend less time solving problems and more time focused on your business. You can have your systems remotely monitored for hardware failure using secure technology that has been proven at thousands of companies around the world. In many cases, you can avoid problems before they occur.

There are two HP Insight Remote Support solutions:

For small and midsize environments: HP Insight Remote Support Standard provides basic remote monitoring, notification/advisories and service dispatch. It is optimized for environments with 1 to

50 servers and can be installed on a shared HP ProLiant Windows application server. The software supports HP EVA storage devices, HP ProLiant, BladeSystems, HP Integrity and HP 9000 servers running Microsoft Windows, Red Hat Enterprise Linux, Novell SUSE and Novell Netware. Download from the HP website

( http://h20392.www2.hp.com/portal/swdepot/displayProductInfo.do?productNumber=RSSWMBA

SE ).

For midsize and large environments: HP Insight Remote Support Pack (formerly Service Essentials

Remote Support Pack) is targeted for larger environments and is integrated with HP Systems Insight

Manager (SIM). It provides comprehensive remote monitoring, notification/advisories, dispatch and proactive service support for nearly all HP servers, storage, network and SAN environments, plus selected Dell and IBM Windows servers that have a support obligation with HP. It also enables HP to deliver higher levels of proactive support in line with HP Mission Critical Services support agreements. Download from the HP website

( http://h20392.www2.hp.com/portal/swdepot/displayProductInfo.do?productNumber=ISDVD ).

Both HP Insight Remote Support solutions are available at no additional cost to customers with a valid warranty on HP technology, an HP Care Pack Service or HP contractual support agreement.

For more information, see the HP website ( http://www.hp.com/go/insightremotesupport ).

Keeping the system current

Drivers

The server includes new hardware that may not have driver support on all operating system installation media.

If you are installing a SmartStart-supported operating system, use the SmartStart software (on page 84 )

and its Assisted Path feature to install the operating system and latest driver support.

Configuration and utilities 93

NOTE: If you are installing drivers from the SmartStart CD or the Software Maintenance CD, refer to the SmartStart website ( http://www.hp.com/servers/smartstart ) to be sure that you are using the latest version of SmartStart. For more information, refer to the documentation provided with the SmartStart CD.

If you do not use the SmartStart CD to install an operating system, drivers for some of the new hardware are required. These drivers, as well as other option drivers, ROM images, and value-add software can be downloaded from the HP website ( http://www.hp.com/support ).

IMPORTANT:

Always perform a backup before installing or updating device drivers.

ProLiant Support Packs

PSPs represent operating system-specific bundles of ProLiant optimized drivers, utilities, and management agents. Refer to the PSP website

( http://h18000.www1.hp.com/products/servers/management/psp.html

).

Operating system version support

Refer to the operating system support matrix ( http://www.hp.com/go/supportos ).

System Online ROM flash component utility

The Online ROM Flash Component Utility enables system administrators to efficiently upgrade system or controller ROM images across a wide range of servers and array controllers. This tool has the following features:

Works offline and online

Supports Windows Server® 2003, Windows Server® 2008, Novell Netware, and Linux operating systems

IMPORTANT: This utility supports operating systems that may not be supported by the server.

For operating systems supported by the server, see the HP website

( http://www.hp.com/support ).

Integrates with other software maintenance, deployment, and operating system tools

Automatically checks for hardware, firmware, and operating system dependencies, and installs only the correct ROM upgrades required by each target server

To download the tool and for more information, see the HP website ( http://www.hp.com/support ).

Change control and proactive notification

HP offers Change Control and Proactive Notification to notify customers 30 to 60 days in advance of upcoming hardware and software changes on HP commercial products.

For more information, refer to the HP website ( http://www.hp.com/go/pcn ).

Configuration and utilities 94

Care Pack

HP Care Pack Services offer upgraded service levels to extend and expand standard product warranty with easy-to-buy, easy-to-use support packages that help you make the most of your server investments.

Refer to the Care Pack website ( http://www.hp.com/hps/carepack/servers/cp_proliant.html

).

Configuration and utilities 95

Troubleshooting

Troubleshooting resources

The HP ProLiant Servers Troubleshooting Guide provides procedures for resolving common problems and comprehensive courses of action for fault isolation and identification, error message interpretation, issue resolution, and software maintenance on ProLiant servers and server blades. This guide includes problemspecific flowcharts to help you navigate complex troubleshooting processes. To view the guide, select a language:

English ( http://www.hp.com/support/ProLiant_TSG_en )

French ( http://www.hp.com/support/ProLiant_TSG_fr )

Italian ( http://www.hp.com/support/ProLiant_TSG_it )

Spanish ( http://www.hp.com/support/ProLiant_TSG_sp )

German ( http://www.hp.com/support/ProLiant_TSG_gr )

Dutch ( http://www.hp.com/support/ProLiant_TSG_nl )

Japanese ( http://www.hp.com/support/ProLiant_TSG_jp )

Pre-diagnostic steps

WARNING: To avoid potential problems, ALWAYS read the warnings and cautionary information in the server documentation before removing, replacing, reseating, or modifying system components.

IMPORTANT: This guide provides information for multiple servers. Some information may not apply to the server you are troubleshooting. Refer to the server documentation for information on procedures, hardware options, software tools, and operating systems supported by the server.

1.

2.

3.

4.

Review the important safety information (on page 96 ).

Gather symptom information (on page 98 ).

Prepare the server for diagnosis (on page 99 ).

Use the Start diagnosis flowchart (on page 100 ) to begin the diagnostic process.

Important safety information

Familiarize yourself with the safety information in the following sections before troubleshooting the server.

Important safety information

Before servicing this product, read the Important Safety Information document provided with the server.

Troubleshooting 96

Symbols on equipment

The following symbols may be placed on equipment to indicate the presence of potentially hazardous conditions.

This symbol indicates the presence of hazardous energy circuits or electric shock hazards. Refer all servicing to qualified personnel.

WARNING: To reduce the risk of injury from electric shock hazards, do not open this enclosure. Refer all maintenance, upgrades, and servicing to qualified personnel.

This symbol indicates the presence of electric shock hazards. The area contains no user or field serviceable parts. Do not open for any reason.

WARNING:

To reduce the risk of injury from electric shock hazards, do not open this enclosure.

This symbol on an RJ-45 receptacle indicates a network interface connection.

WARNING:

To reduce the risk of electric shock, fire, or damage to the equipment, do not plug telephone or telecommunications connectors into this receptacle.

This symbol indicates the presence of a hot surface or hot component. If this surface is contacted, the potential for injury exists.

WARNING: To reduce the risk of injury from a hot component, allow the surface to cool before touching.

15.0 kg

33.0 lb

This symbol indicates that the component exceeds the recommended weight for one individual to handle safely.

WARNING: To reduce the risk of personal injury or damage to the equipment, observe local occupational health and safety requirements and guidelines for manual material handling.

These symbols, on power supplies or systems, indicate that the equipment is supplied by multiple sources of power.

WARNING: To reduce the risk of injury from electric shock, remove all power cords to completely disconnect power from the system.

Warnings and cautions

WARNING: Only authorized technicians trained by HP should attempt to repair this equipment. All troubleshooting and repair procedures are detailed to allow only subassembly/module-level repair. Because of the complexity of the individual boards and subassemblies, no one should attempt to make repairs at the component level or to make modifications to any printed wiring board. Improper repairs can create a safety hazard.

WARNING:

To reduce the risk of personal injury or damage to the equipment, be sure that:

The leveling feet are extended to the floor.

• The full weight of the rack rests on the leveling feet.

• The stabilizing feet are attached to the rack if it is a single-rack installation.

The racks are coupled together in multiple-rack installations.

Only one component is extended at a time. A rack may become unstable if more than one component is extended for any reason.

Troubleshooting 97

WARNING: To reduce the risk of electric shock or damage to the equipment:

• Do not disable the power cord grounding plug. The grounding plug is an important safety feature.

Plug the power cord into a grounded (earthed) electrical outlet that is easily accessible at all times.

• Unplug the power cord from the power supply to disconnect power to the equipment.

Do not route the power cord where it can be walked on or pinched by items placed against it. Pay particular attention to the plug, electrical outlet, and the point where the cord extends from the server.

15.0 kg

33.0 lb

WARNING: To reduce the risk of personal injury or damage to the equipment:

• Observe local occupation health and safety requirements and guidelines for manual handling.

Obtain adequate assistance to lift and stabilize the chassis during installation or removal.

• The server is unstable when not fastened to the rails.

When mounting the server in a rack, remove the power supplies and any other removable module to reduce the overall weight of the product.

CAUTION: To properly ventilate the system, you must provide at least 7.6 cm (3.0 in) of clearance at the front and back of the server.

CAUTION: The server is designed to be electrically grounded (earthed). To ensure proper operation, plug the AC power cord into a properly grounded AC outlet only.

Symptom information

Before troubleshooting a server problem, collect the following information:

What events preceded the failure? After which steps does the problem occur?

What has been changed since the time the server was working?

Did you recently add or remove hardware or software? If so, did you remember to change the appropriate settings in the server setup utility, if necessary?

How long has the server exhibited problem symptoms?

If the problem occurs randomly, what is the duration or frequency?

To answer these questions, the following information may be useful:

Run HP Insight Diagnostics (on page 91 ) and use the survey page to view the current configuration

or to compare it to previous configurations.

Refer to your hardware and software records for information.

Refer to server LEDs and their statuses.

Troubleshooting 98

Prepare the server for diagnosis

1.

2.

3.

4.

5.

6.

Be sure the server is in the proper operating environment with adequate power, air conditioning, and humidity control. For required environmental conditions, see the server documentation.

Record any error messages displayed by the system.

Remove all diskettes, CD-ROMs, DVD-ROMs, and USB drive keys.

Power down the server and peripheral devices if you will be diagnosing the server offline. If possible, always perform an orderly shutdown: a.

Exit any applications. b. c.

Exit the operating system.

Power down the server (on page 20 ).

Disconnect any peripheral devices not required for testing (any devices not necessary to power up the server). Do not disconnect the printer if you want to use it to print error messages.

Collect all tools and utilities, such as a Torx screwdriver, loopback adapters, ESD wrist strap, and software utilities, necessary to troubleshoot the problem. o

You must have the appropriate Health Drivers and Management Agents installed on the server.

To verify the server configuration, connect to the System Management homepage and select

Version Control Agent. The VCA gives you a list of names and versions of all installed HP drivers,

Management Agents, and utilities, and whether they are up-to-date. o o

HP recommends you have access to the server documentation for server-specific information.

HP recommends you have access to the SmartStart CD for value-added software and drivers required during the troubleshooting process. Download the current version of SmartStart from the

HP website ( http://www.hp.com/servers/smartstart ).

Loose connections

Action:

Be sure all power cords are securely connected.

Be sure all cables are properly aligned and securely connected for all external and internal components.

Remove and check all data and power cables for damage. Be sure no cables have bent pins or damaged connectors.

If a fixed cable tray is available for the server, be sure the cords and cables connected to the server are routed correctly through the tray.

Be sure each device is properly seated. Avoid bending or flexing circuit boards when reseating components.

If a device has latches, be sure they are completely closed and locked.

Check any interlock or interconnect LEDs that may indicate a component is not connected properly.

If problems continue to occur, remove and reinstall each device, checking the connectors and sockets for bent pins or other damage.

Troubleshooting 99

Service notifications

To view the latest service notifications, refer to the HP website ( http://www.hp.com/go/bizsupport ).

Select the appropriate server model, and then click the Troubleshoot a Problem link on the product page.

Troubleshooting flowcharts

To effectively troubleshoot a problem, HP recommends that you start with the first flowchart in this section,

"Start diagnosis flowchart (on page 100 )," and follow the appropriate diagnostic path. If the other

flowcharts do not provide a troubleshooting solution, follow the diagnostic steps in "General diagnosis

flowchart (on page 101 )." The General diagnosis flowchart is a generic troubleshooting process to be

used when the problem is not server-specific or is not easily categorized into the other flowcharts.

The available flowcharts include:

Start diagnosis flowchart (on page 100 )

General diagnosis flowchart (on page 101 )

Server power-on problems flowchart (on page 103 )

POST problems flowchart (on page 106 )

OS boot problems flowchart (on page 107 )

Server fault indications flowchart (on page 109 )

Start diagnosis flowchart

3

4

5

1

2

Use the following flowchart to start the diagnostic process.

Item Refer to

"General diagnosis flowchart (on page 101 )"

"Power-on problems flowchart (" Server power-on problems flowchart " on page 103 )"

"POST problems flowchart (on page 106 )"

"OS boot problems flowchart (on page 107 )"

"Server fault indications flowchart (on page 109 )"

Troubleshooting 100

General diagnosis flowchart

3

4

1

2

The General diagnosis flowchart provides a generic approach to troubleshooting. If you are unsure of the problem, or if the other flowcharts do not fix the problem, use the following flowchart.

Item Refer to

"Symptom information (on page 98 )"

"Loose connections (on page 99 )"

"Service notifications (on page 100 )"

The most recent version of a particular server or option firmware is available on the HP Support website ( http://www.hp.com/support ).

Troubleshooting 101

Item

5

6

7

8

9

Refer to

"General memory problems are occurring" in the HP ProLiant Servers

Troubleshooting Guide located on the Documentation CD or on the HP website ( http://www.hp.com/support )

Server maintenance and service guide, located on the Documentation

CD or the HP website

( http://www.hp.com/products/servers/platforms )

Server maintenance and service guide, located on the

Documentation CD or the HP website

( http://www.hp.com/products/servers/platforms )

"Hardware problems" in the HP ProLiant Servers Troubleshooting

Guide located on the Documentation CD or on the HP website

( http://www.hp.com/support )

"Server information you need" in the HP ProLiant Servers

Troubleshooting Guide located on the Documentation CD or on the

HP website ( http://www.hp.com/support )

"Operating system information you need" in the HP ProLiant Servers

Troubleshooting Guide located on the Documentation CD or on the

HP website ( http://www.hp.com/support )

"HP contact information (on page 123 )"

Troubleshooting 102

Server power-on problems flowchart

Symptoms:

The server does not power on.

The system power LED is off or amber.

Troubleshooting 103

The external health LED is red or amber.

The internal health LED is red or amber.

NOTE: For the location of server LEDs and information on their statuses, refer to the server documentation.

3

4

1

2

Possible causes:

Improperly seated or faulty power supply

Loose or faulty power cord

Power source problem

Power on circuit problem

Improperly seated component or interlock problem

Faulty internal component

Item Refer to

5

6

7

8

"Component identification (on page 7 )"

"HP Insight Diagnostics (on page 91 )" or in the HP ProLiant Servers

Troubleshooting Guide located on the Documentation CD or on the HP website ( http://www.hp.com/support )

"Loose connections (on page 99 )"

Server maintenance and service guide, located on the Documentation

CD, or the HP website

( http://www.hp.com/products/servers/platforms )

"Integrated Management Log (on page 92 )" or in the HP ProLiant

Servers Troubleshooting Guide located on the Documentation CD or on the HP website ( http://www.hp.com/support )

"Power source problems" in the HP ProLiant Servers Troubleshooting

Guide located on the Documentation CD or on the HP website

( http://www.hp.com/support )

"Power supply problems" in the HP ProLiant Servers Troubleshooting

Guide located on the Documentation CD or on the HP website

( http://www.hp.com/support )

Server maintenance and service guide, located on the

Documentation CD, or the HP website

( http://www.hp.com/products/servers/platforms )

"System open circuits and short circuits" in the HP ProLiant Servers

Troubleshooting Guide located on the Documentation CD or on the HP website ( http://www.hp.com/support )

Troubleshooting 104

Troubleshooting 105

POST problems flowchart

Symptoms:

Server does not complete POST

NOTE:

The server has completed POST when the system attempts to access the boot device.

Server completes POST with errors

5

6

3

4

1

2

Possible problems:

Improperly seated or faulty internal component

Faulty KVM device

Faulty video device

Item Refer to

7

8

"POST error messages and beep codes (on page 111 )"

"Video problems" in the HP ProLiant Servers Troubleshooting Guide located on the Documentation CD or on the HP website

( http://www.hp.com/support )

KVM or iLO 2 documentation

"Loose connections (on page 99 )"

"Symptom information (on page 98 )"

Server maintenance and service guide, located on the Documentation

CD or the HP website

( http://www.hp.com/products/servers/platforms )

"Port 85 and iLO messages" in the HP ProLiant Servers Troubleshooting

Guide located on the Documentation CD or on the HP website

( http://www.hp.com/support )

"General memory problems are occurring" in the HP ProLiant Servers

Troubleshooting Guide located on the Documentation CD or on the HP website ( http://www.hp.com/support )

9

10

"Hardware problems" in the HP ProLiant Servers Troubleshooting

Guide located on the Documentation CD or on the HP website

( http://www.hp.com/support )

Server maintenance and service guide, located on the

Documentation CD or the HP website

( http://www.hp.com/products/servers/platforms )

"Server information you need" in the HP ProLiant Servers

Troubleshooting Guide located on the Documentation CD or on the

HP website ( http://www.hp.com/support )

"Operating system information you need" in the HP ProLiant Servers

Troubleshooting Guide located on the Documentation CD or on the

HP website ( http://www.hp.com/support )

Troubleshooting 106

Item Refer to

OS boot problems flowchart

Symptoms:

Server does not boot a previously installed operating system

Troubleshooting 107

Server does not boot SmartStart

2

3

Possible causes:

Corrupted operating system

Hard drive subsystem problem

Incorrect boot order setting in RBSU

Item Refer to

1

4

5

6

7

8

9

HP ROM-Based Setup Utility User Guide

( http://www.hp.com/servers/smartstart )

"POST problems flowchart (on page 106 )"

"Hard drive problems" in the HP ProLiant Servers Troubleshooting

Guide located on the Documentation CD or on the HP website

( http://www.hp.com/support )

Controller documentation

"HP Insight Diagnostics (on page 91 )" or in the HP ProLiant Servers

Troubleshooting Guide located on the Documentation CD or on the HP website ( http://www.hp.com/support )

"CD-ROM and DVD drive problems" in the HP ProLiant Servers

Troubleshooting Guide located on the Documentation CD or on the

HP website ( http://www.hp.com/support )

Controller documentation

"Loose connections (on page 99 )"

"General memory problems are occurring" in the HP ProLiant Servers

Troubleshooting Guide located on the Documentation CD or on the HP website ( http://www.hp.com/support )

"Operating system problems" in the HP ProLiant Servers

Troubleshooting Guide located on the Documentation CD or on the

HP website ( http://www.hp.com/support )

"HP contact information (on page 123 )"

"Hardware problems" in the HP ProLiant Servers Troubleshooting

Guide located on the Documentation CD or on the HP website

( http://www.hp.com/support )

Server maintenance and service guide, located on the

Documentation CD or the HP website

( http://www.hp.com/products/servers/platforms )

"General diagnosis flowchart (on page 101 )"

Troubleshooting 108

Server fault indications flowchart

Symptoms:

Server boots, but a fault event is reported by Insight Management Agents (on page 90 )

Server boots, but the internal health LED, external health LED, or component health LED is red or amber

Troubleshooting 109

NOTE: For the location of server LEDs and information on their statuses, refer to the server documentation.

3

4

5

Possible causes:

Improperly seated or faulty internal or external component

Unsupported component installed

Redundancy failure

System overtemperature condition

Item Refer to

1

2

6

7

8

"Management agents (on page 90 )" or in the HP ProLiant Servers

Troubleshooting Guide located on the Documentation CD or on the HP website ( http://www.hp.com/support )

"Integrated Management Log (on page 92 )" or in the HP ProLiant

Servers Troubleshooting Guide located on the Documentation CD or on the HP website ( http://www.hp.com/support )

"Event list error messages" in the HP ProLiant Servers

Troubleshooting Guide located on the Documentation CD or on the

HP website ( http://www.hp.com/support )

"Component identification (on page 7 )"

System Management Homepage ( https://localhost:2381 )

"Power-on problems flowchart (" Server power-on problems flowchart " on page 103 )"

"Smart Array SCSI Diagnosis feature" in the HP ProLiant Servers

Troubleshooting Guide located on the Documentation CD or on the

HP website ( http://www.hp.com/support )

Server maintenance and service guide, located on the

Documentation CD or the HP website

( http://www.hp.com/products/servers/platforms )

"HP contact information (on page 123 )"

"HP Insight Diagnostics (on page 91 )" or in the HP ProLiant Servers

Troubleshooting Guide located on the Documentation CD or on the HP website ( http://www.hp.com/support )

"Hardware problems" in the HP ProLiant Servers Troubleshooting

Guide located on the Documentation CD or on the HP website

( http://www.hp.com/support )

Server maintenance and service guide, located on the

Documentation CD or the HP website

( http://www.hp.com/products/servers/platforms )

Troubleshooting 110

POST error messages and beep codes

For a complete listing of error messages, refer to the "POST error messages" in the HP ProLiant Servers

Troubleshooting Guide located on the Documentation CD or on the HP website

( http://www.hp.com/support ).

WARNING: To avoid potential problems, ALWAYS read the warnings and cautionary information in the server documentation before removing, replacing, reseating, or modifying system components.

Troubleshooting 111

Battery replacement

If the server no longer automatically displays the correct date and time, you may need to replace the battery that provides power to the real-time clock. Under normal use, battery life is 5 to 10 years.

WARNING: The computer contains an internal lithium manganese dioxide, a vanadium pentoxide, or an alkaline battery pack. A risk of fire and burns exists if the battery pack is not properly handled. To reduce the risk of personal injury:

Do not attempt to recharge the battery.

• Do not expose the battery to temperatures higher than 60°C (140°F).

• Do not disassemble, crush, puncture, short external contacts, or dispose of in fire or water.

Replace only with the spare designated for this product.

To remove the component:

1.

Power down the server (on page 20 ).

2.

Do one of the following: o

Open or remove the tower bezel, as needed (" Open or remove the tower bezel " on page 20 ).

3.

4. o

Extend the server from the rack (on page 21 ).

Remove the access panel (on page 21 ).

Remove the battery.

IMPORTANT:

Replacing the system board battery resets the system ROM to its default configuration. After replacing the battery, reconfigure the system through RBSU.

To replace the component, reverse the removal procedure.

For more information about battery replacement or proper disposal, contact an authorized reseller or an authorized service provider.

Battery replacement 112

Regulatory compliance notices

Regulatory compliance identification numbers

For the purpose of regulatory compliance certifications and identification, this product has been assigned a unique regulatory model number. The regulatory model number can be found on the product nameplate label, along with all required approval markings and information. When requesting compliance information for this product, always refer to this regulatory model number. The regulatory model number is not the marketing name or model number of the product.

Federal Communications Commission notice

Part 15 of the Federal Communications Commission (FCC) Rules and Regulations has established Radio

Frequency (RF) emission limits to provide an interference-free radio frequency spectrum. Many electronic devices, including computers, generate RF energy incidental to their intended function and are, therefore, covered by these rules. These rules place computers and related peripheral devices into two classes, A and B, depending upon their intended installation. Class A devices are those that may reasonably be expected to be installed in a business or commercial environment. Class B devices are those that may reasonably be expected to be installed in a residential environment (for example, personal computers).

The FCC requires devices in both classes to bear a label indicating the interference potential of the device as well as additional operating instructions for the user.

FCC rating label

The FCC rating label on the device shows the classification (A or B) of the equipment. Class B devices have an FCC logo or ID on the label. Class A devices do not have an FCC logo or ID on the label. After you determine the class of the device, refer to the corresponding statement.

Class A equipment

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at personal expense.

Class B equipment

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference

Regulatory compliance notices 113

to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment into an outlet on a circuit that is different from that to which the receiver is connected.

Consult the dealer or an experienced radio or television technician for help.

Declaration of conformity for products marked with the FCC logo, United States only

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

(1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

For questions regarding this product, contact us by mail or telephone:

Hewlett-Packard Company

P. O. Box 692000, Mail Stop 530113

Houston, Texas 77269-2000

1-800-HP-INVENT (1-800-474-6836). (For continuous quality improvement, calls may be recorded or monitored.)

For questions regarding this FCC declaration, contact us by mail or telephone:

Hewlett-Packard Company

P. O. Box 692000, Mail Stop 510101

Houston, Texas 77269-2000

1-281-514-3333

To identify this product, refer to the part, series, or model number found on the product.

Modifications

The FCC requires the user to be notified that any changes or modifications made to this device that are not expressly approved by Hewlett-Packard Company may void the user’s authority to operate the equipment.

Cables

Connections to this device must be made with shielded cables with metallic RFI/EMI connector hoods in order to maintain compliance with FCC Rules and Regulations.

Regulatory compliance notices 114

Canadian notice (Avis Canadien)

Class A equipment

This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment

Regulations.

Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.

Class B equipment

This Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment

Regulations.

Cet appareil numérique de la classe B respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.

European Union regulatory notice

This product complies with the following EU Directives:

Low Voltage Directive 2006/95/EC

EMC Directive 2004/108/EC

Compliance with these directives implies conformity to applicable harmonized European standards

(European Norms) which are listed on the EU Declaration of Conformity issued by Hewlett-Packard for this product or product family.

This compliance is indicated by the following conformity marking placed on the product:

This marking is valid for non-Telecom products and EU harmonized Telecom products (e.g. Bluetooth).

This marking is valid for EU non-harmonized Telecom products.

*Notified body number (used only if applicable—refer to the product label)

Hewlett-Packard GmbH, HQ-TRE, Herrenberger Strasse 140, 71034 Boeblingen, Germany

The official EU CE declaration of conformity for this device can be found on the HP website

( http://www.hp.com/go/certificates ).

Disposal of waste equipment by users in private households in the European Union

Regulatory compliance notices 115

This symbol on the product or on its packaging indicates that this product must not be disposed of with your other household waste. Instead, it is your responsibility to dispose of your waste equipment by handing it over to a designated collection point for the recycling of waste electrical and electronic equipment. The separate collection and recycling of your waste equipment at the time of disposal will help to conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment. For more information about where you can drop off your waste equipment for recycling, please contact your local city office, your household waste disposal service or the shop where you purchased the product.

Japanese notice

BSMI notice

Regulatory compliance notices 116

Korean notice

Class A equipment

Class B equipment

Chinese notice

Class A equipment

Laser compliance

This product may be provided with an optical storage device (that is, CD or DVD drive) and/or fiber optic transceiver. Each of these devices contains a laser that is classified as a Class 1 Laser Product in accordance with US FDA regulations and the IEC 60825-1. The product does not emit hazardous laser radiation.

Each laser product complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to Laser

Notice No. 50, dated May 27, 2001; and with IEC 60825-1:1993/A2:2001.

WARNING: Use of controls or adjustments or performance of procedures other than those specified herein or in the laser product's installation guide may result in hazardous radiation exposure. To reduce the risk of exposure to hazardous radiation:

Do not try to open the module enclosure. There are no user-serviceable components inside.

• Do not operate controls, make adjustments, or perform procedures to the laser device other than those specified herein.

Allow only HP Authorized Service technicians to repair the unit.

The Center for Devices and Radiological Health (CDRH) of the U.S. Food and Drug Administration implemented regulations for laser products on August 2, 1976. These regulations apply to laser products manufactured from August 1, 1976. Compliance is mandatory for products marketed in the United States.

Battery replacement notice

Regulatory compliance notices 117

WARNING: The computer contains an internal lithium manganese dioxide, a vanadium pentoxide, or an alkaline battery pack. A risk of fire and burns exists if the battery pack is not properly handled. To reduce the risk of personal injury:

• Do not attempt to recharge the battery.

• Do not expose the battery to temperatures higher than 60°C (140°F).

Do not disassemble, crush, puncture, short external contacts, or dispose of in fire or water.

Batteries, battery packs, and accumulators should not be disposed of together with the general household waste. To forward them to recycling or proper disposal, use the public collection system or return them to HP, an authorized HP Partner, or their agents.

For more information about battery replacement or proper disposal, contact an authorized reseller or an authorized service provider.

Taiwan battery recycling notice

The Taiwan EPA requires dry battery manufacturing or importing firms in accordance with Article 15 of the Waste Disposal Act to indicate the recovery marks on the batteries used in sales, giveaway or promotion. Contact a qualified Taiwanese recycler for proper battery disposal.

Power cord statement for Japan

Regulatory compliance notices 118

Electrostatic discharge

Preventing electrostatic discharge

To prevent damaging the system, be aware of the precautions you need to follow when setting up the system or handling parts. A discharge of static electricity from a finger or other conductor may damage system boards or other static-sensitive devices. This type of damage may reduce the life expectancy of the device.

To prevent electrostatic damage:

Avoid hand contact by transporting and storing products in static-safe containers.

Keep electrostatic-sensitive parts in their containers until they arrive at static-free workstations.

Place parts on a grounded surface before removing them from their containers.

Avoid touching pins, leads, or circuitry.

Always be properly grounded when touching a static-sensitive component or assembly.

Grounding methods to prevent electrostatic discharge

Several methods are used for grounding. Use one or more of the following methods when handling or installing electrostatic-sensitive parts:

Use a wrist strap connected by a ground cord to a grounded workstation or computer chassis. Wrist straps are flexible straps with a minimum of 1 megohm ±10 percent resistance in the ground cords.

To provide proper ground, wear the strap snug against the skin.

Use heel straps, toe straps, or boot straps at standing workstations. Wear the straps on both feet when standing on conductive floors or dissipating floor mats.

Use conductive field service tools.

Use a portable field service kit with a folding static-dissipating work mat.

If you do not have any of the suggested equipment for proper grounding, have an authorized reseller install the part.

For more information on static electricity or assistance with product installation, contact an authorized reseller.

Electrostatic discharge 119

Specifications

Environmental specifications

Specification Value

Temperature

Operating 1

Non-operating

Maximum rate of temperature change

10°C to 35°C (50°F to 90°F)

30°C to 60°C (-22°F to 140°F)

Operating 2,3

Non-operating

Relative humidity

(noncondensing)***

10°C/hr (18°F/hr)

20°C/hr (36°F/hr)

Operating

Non-operating

Maximum wet bulb temperature (non-condensing)

10% to 90%

5% to 95%

Operating

Non-operating

28°C (82.4°F)

38.7°C (101.7°F)

Altitude

Operating 2

Non-operating

3,050 m (10,000 ft)

9144 m (30,000 ft)

Maximum rate of altitude change

Operating 3,000 m (10,000 ft)

Non-operating 9,144 m (30,000 ft)

1 All temperature ratings shown are for sea level. An altitude derating of 1°C per 300 m (1.8°F per 1,000 ft) to 3048 m (10,000 ft) is applicable. No direct sunlight is allowed.

2 The type and number of options installed can limit the upper limit.

3

System performance may be reduced if operating with a fan fault above 30ºC (86ºF).

Mechanical specifications

Specification Value

Height 20.0 cm (7.87 in)

Depth (without bezel)

Width

42.70 cm (16.81 in)

61.30 cm (24.13 in)

Weight (no drives installed) 16.04 kg (35.37 lb)

Specifications 120

Power supply specifications

Depending on installed options, the server is configured with one of the following power supplies:

HP ProLiant 750 W Power Supply

Specification Value

Input requirements

Rated input voltage

Rated input frequency

Rated input current

Rated input power

BTUs per hour

100 to 120 VAC, 200 to

240 VAC

50 Hz to 60 Hz

9.4 A at 100 VAC

4.7 A at 200 VAC

857 W at 100V AC input

852 W at 200V AC input

2924 at 100V AC input

2907 at 200V AC input

Power supply output

Rated steady-state power 750 W at 100V to 120V AC input

750 W at 200V to 240V AC input

Maximum peak power 750 W at 100V to 120V AC input

750 W at 200V to 240V AC input

HP ProLiant 460 W Power Supply

Specification Value

Input requirements

Rated input voltage

Rated input frequency

Rated input current

Rated input power

BTUs per hour

100 to 120 VAC, 200 to

240 VAC

50 Hz to 60 Hz

10.0 A at 100 VAC

5.0 A at 200 VAC

626 W at 100V AC input

676 W at 200V AC input

2306 at 100V AC input

2306 at 200V AC input

Power supply output

Rated steady-state power 460 W at 100V to 120V AC input

460 W at 200V to 240V AC input

Specifications 121

Maximum peak power 460 W at 100V to 120V AC input

460 W at 200V to 240V AC input

Specifications 122

Technical support

Before you contact HP

Be sure to have the following information available before you call HP:

Technical support registration number (if applicable)

Product serial number

Product model name and number

Product identification number

Applicable error messages

Add-on boards or hardware

Third-party hardware or software

Operating system type and revision level

HP contact information

For the name of the nearest HP authorized reseller:

See the Contact HP worldwide (in English) webpage

( http://welcome.hp.com/country/us/en/wwcontact.html

).

For HP technical support:

In the United States, for contact options see the Contact HP United States webpage

( http://welcome.hp.com/country/us/en/contact_us.html

). To contact HP by phone: o o

Call 1-800-HP-INVENT (1-800-474-6836). This service is available 24 hours a day, 7 days a week. For continuous quality improvement, calls may be recorded or monitored.

If you have purchased a Care Pack (service upgrade), call 1-800-633-3600. For more information about Care Packs, refer to the HP website ( http://www.hp.com/hps ).

In other locations, see the Contact HP worldwide (in English) webpage

( http://welcome.hp.com/country/us/en/wwcontact.html

).

Customer Self Repair

HP products are designed with many Customer Self Repair (CSR) parts to minimize repair time and allow for greater flexibility in performing defective parts replacement. If during the diagnosis period HP (or HP service providers or service partners) identifies that the repair can be accomplished by the use of a CSR part, HP will ship that part directly to you for replacement. There are two categories of CSR parts:

Mandatory—Parts for which customer self repair is mandatory. If you request HP to replace these parts, you will be charged for the travel and labor costs of this service.

Technical support 123

Optional—Parts for which customer self repair is optional. These parts are also designed for customer self repair. If, however, you require that HP replace them for you, there may or may not be additional charges, depending on the type of warranty service designated for your product.

NOTE: Some HP parts are not designed for customer self repair. In order to satisfy the customer warranty,

HP requires that an authorized service provider replace the part. These parts are identified as "No" in the

Illustrated Parts Catalog.

Based on availability and where geography permits, CSR parts will be shipped for next business day delivery. Same day or four-hour delivery may be offered at an additional charge where geography permits. If assistance is required, you can call the HP Technical Support Center and a technician will help you over the telephone. HP specifies in the materials shipped with a replacement CSR part whether a defective part must be returned to HP. In cases where it is required to return the defective part to HP, you must ship the defective part back to HP within a defined period of time, normally five (5) business days.

The defective part must be returned with the associated documentation in the provided shipping material.

Failure to return the defective part may result in HP billing you for the replacement. With a customer self repair, HP will pay all shipping and part return costs and determine the courier/carrier to be used.

For more information about HP's Customer Self Repair program, contact your local service provider. For the North American program, refer to the HP website ( http://www.hp.com/go/selfrepair ).

Réparation par le client (CSR)

Les produits HP comportent de nombreuses pièces CSR (Customer Self Repair = réparation par le client) afin de minimiser les délais de réparation et faciliter le remplacement des pièces défectueuses. Si pendant la période de diagnostic, HP (ou ses partenaires ou mainteneurs agréés) détermine que la réparation peut

être effectuée à l'aide d'une pièce CSR, HP vous l'envoie directement. Il existe deux catégories de pièces

CSR:

Obligatoire - Pièces pour lesquelles la réparation par le client est obligatoire. Si vous demandez à HP de remplacer ces pièces, les coûts de déplacement et main d'œuvre du service vous seront facturés.

Facultatif - Pièces pour lesquelles la réparation par le client est facultative. Ces pièces sont également conçues pour permettre au client d'effectuer lui-même la réparation. Toutefois, si vous demandez à HP de remplacer ces pièces, l'intervention peut ou non vous être facturée, selon le type de garantie applicable à votre produit.

REMARQUE: Certaines pièces HP ne sont pas conçues pour permettre au client d'effectuer lui-même la réparation. Pour que la garantie puisse s'appliquer, HP exige que le remplacement de la pièce soit effectué par un Mainteneur Agréé. Ces pièces sont identifiées par la mention "Non" dans le Catalogue illustré.

Les pièces CSR sont livrées le jour ouvré suivant, dans la limite des stocks disponibles et selon votre situation géographique. Si votre situation géographique le permet et que vous demandez une livraison le jour même ou dans les 4 heures, celle-ci vous sera facturée. Pour bénéficier d'une assistance téléphonique, appelez le Centre d'assistance technique HP. Dans les documents envoyés avec la pièce de rechange CSR, HP précise s'il est nécessaire de lui retourner la pièce défectueuse. Si c'est le cas, vous devez le faire dans le délai indiqué, généralement cinq (5) jours ouvrés. La pièce et sa documentation doivent être retournées dans l'emballage fourni. Si vous ne retournez pas la pièce défectueuse, HP se réserve le droit de vous facturer les coûts de remplacement. Dans le cas d'une pièce CSR, HP supporte l'ensemble des frais d'expédition et de retour, et détermine la société de courses ou le transporteur à utiliser.

Technical support 124

Pour plus d'informations sur le programme CSR de HP, contactez votre Mainteneur Agrée local. Pour plus d'informations sur ce programme en Amérique du Nord, consultez le site Web HP

( http://www.hp.com/go/selfrepair ).

Riparazione da parte del cliente

Per abbreviare i tempi di riparazione e garantire una maggiore flessibilità nella sostituzione di parti difettose, i prodotti HP sono realizzati con numerosi componenti che possono essere riparati direttamente dal cliente (CSR, Customer Self Repair). Se in fase di diagnostica HP (o un centro di servizi o di assistenza HP) identifica il guasto come riparabile mediante un ricambio CSR, HP lo spedirà direttamente al cliente per la sostituzione. Vi sono due categorie di parti CSR:

Obbligatorie – Parti che devono essere necessariamente riparate dal cliente. Se il cliente ne affida la riparazione ad HP, deve sostenere le spese di spedizione e di manodopera per il servizio.

Opzionali – Parti la cui riparazione da parte del cliente è facoltativa. Si tratta comunque di componenti progettati per questo scopo. Se tuttavia il cliente ne richiede la sostituzione ad HP, potrebbe dover sostenere spese addizionali a seconda del tipo di garanzia previsto per il prodotto.

NOTA: alcuni componenti HP non sono progettati per la riparazione da parte del cliente. Per rispettare la garanzia, HP richiede che queste parti siano sostituite da un centro di assistenza autorizzato. Tali parti sono identificate da un "No" nel Catalogo illustrato dei componenti.

In base alla disponibilità e alla località geografica, le parti CSR vengono spedite con consegna entro il giorno lavorativo seguente. La consegna nel giorno stesso o entro quattro ore è offerta con un supplemento di costo solo in alcune zone. In caso di necessità si può richiedere l'assistenza telefonica di un addetto del centro di supporto tecnico HP. Nel materiale fornito con una parte di ricambio CSR, HP specifica se il cliente deve restituire dei componenti. Qualora sia richiesta la resa ad HP del componente difettoso, lo si deve spedire ad HP entro un determinato periodo di tempo, generalmente cinque (5) giorni lavorativi. Il componente difettoso deve essere restituito con la documentazione associata nell'imballo di spedizione fornito. La mancata restituzione del componente può comportare la fatturazione del ricambio da parte di HP. Nel caso di riparazione da parte del cliente, HP sostiene tutte le spese di spedizione e resa e sceglie il corriere/vettore da utilizzare.

Per ulteriori informazioni sul programma CSR di HP contattare il centro di assistenza di zona. Per il programma in Nord America fare riferimento al sito Web HP ( http://www.hp.com/go/selfrepair ).

Customer Self Repair

HP Produkte enthalten viele CSR-Teile (Customer Self Repair), um Reparaturzeiten zu minimieren und höhere Flexibilität beim Austausch defekter Bauteile zu ermöglichen. Wenn HP (oder ein HP

Servicepartner) bei der Diagnose feststellt, dass das Produkt mithilfe eines CSR-Teils repariert werden kann, sendet Ihnen HP dieses Bauteil zum Austausch direkt zu. CSR-Teile werden in zwei Kategorien unterteilt:

Zwingend – Teile, für die das Customer Self Repair-Verfahren zwingend vorgegeben ist. Wenn Sie den

Austausch dieser Teile von HP vornehmen lassen, werden Ihnen die Anfahrt- und Arbeitskosten für diesen

Service berechnet.

Optional – Teile, für die das Customer Self Repair-Verfahren optional ist. Diese Teile sind auch für

Customer Self Repair ausgelegt. Wenn Sie jedoch den Austausch dieser Teile von HP vornehmen lassen möchten, können bei diesem Service je nach den für Ihr Produkt vorgesehenen Garantiebedingungen zusätzliche Kosten anfallen.

Technical support 125

HINWEIS: Einige Teile sind nicht für Customer Self Repair ausgelegt. Um den Garantieanspruch des

Kunden zu erfüllen, muss das Teil von einem HP Servicepartner ersetzt werden. Im illustrierten Teilekatalog sind diese Teile mit „No“ bzw. „Nein“ gekennzeichnet.

CSR-Teile werden abhängig von der Verfügbarkeit und vom Lieferziel am folgenden Geschäftstag geliefert. Für bestimmte Standorte ist eine Lieferung am selben Tag oder innerhalb von vier Stunden gegen einen Aufpreis verfügbar. Wenn Sie Hilfe benötigen, können Sie das HP technische Support Center anrufen und sich von einem Mitarbeiter per Telefon helfen lassen. Den Materialien, die mit einem CSR-

Ersatzteil geliefert werden, können Sie entnehmen, ob das defekte Teil an HP zurückgeschickt werden muss. Wenn es erforderlich ist, das defekte Teil an HP zurückzuschicken, müssen Sie dies innerhalb eines vorgegebenen Zeitraums tun, in der Regel innerhalb von fünf (5) Geschäftstagen. Das defekte Teil muss mit der zugehörigen Dokumentation in der Verpackung zurückgeschickt werden, die im Lieferumfang enthalten ist. Wenn Sie das defekte Teil nicht zurückschicken, kann HP Ihnen das Ersatzteil in Rechnung stellen. Im Falle von Customer Self Repair kommt HP für alle Kosten für die Lieferung und Rücksendung auf und bestimmt den Kurier-/Frachtdienst.

Weitere Informationen über das HP Customer Self Repair Programm erhalten Sie von Ihrem Servicepartner vor Ort. Informationen über das CSR-Programm in Nordamerika finden Sie auf der HP Website unter

( http://www.hp.com/go/selfrepair ).

Reparaciones del propio cliente

Los productos de HP incluyen muchos componentes que el propio usuario puede reemplazar (Customer

Self Repair, CSR) para minimizar el tiempo de reparación y ofrecer una mayor flexibilidad a la hora de realizar sustituciones de componentes defectuosos. Si, durante la fase de diagnóstico, HP (o los proveedores o socios de servicio de HP) identifica que una reparación puede llevarse a cabo mediante el uso de un componente CSR, HP le enviará dicho componente directamente para que realice su sustitución. Los componentes CSR se clasifican en dos categorías:

Obligatorio: componentes para los que la reparación por parte del usuario es obligatoria. Si solicita a HP que realice la sustitución de estos componentes, tendrá que hacerse cargo de los gastos de desplazamiento y de mano de obra de dicho servicio.

Opcional: componentes para los que la reparación por parte del usuario es opcional. Estos componentes también están diseñados para que puedan ser reparados por el usuario. Sin embargo, si precisa que HP realice su sustitución, puede o no conllevar costes adicionales, dependiendo del tipo de servicio de garantía correspondiente al producto.

NOTA: Algunos componentes no están diseñados para que puedan ser reparados por el usuario. Para que el usuario haga valer su garantía, HP pone como condición que un proveedor de servicios autorizado realice la sustitución de estos componentes. Dichos componentes se identifican con la palabra

"No" en el catálogo ilustrado de componentes.

Según la disponibilidad y la situación geográfica, los componentes CSR se enviarán para que lleguen a su destino al siguiente día laborable. Si la situación geográfica lo permite, se puede solicitar la entrega en el mismo día o en cuatro horas con un coste adicional. Si precisa asistencia técnica, puede llamar al

Centro de asistencia técnica de HP y recibirá ayuda telefónica por parte de un técnico. Con el envío de materiales para la sustitución de componentes CSR, HP especificará si los componentes defectuosos deberán devolverse a HP. En aquellos casos en los que sea necesario devolver algún componente a HP, deberá hacerlo en el periodo de tiempo especificado, normalmente cinco días laborables. Los componentes defectuosos deberán devolverse con toda la documentación relacionada y con el embalaje de envío. Si no enviara el componente defectuoso requerido, HP podrá cobrarle por el de sustitución. En

Technical support 126

el caso de todas sustituciones que lleve a cabo el cliente, HP se hará cargo de todos los gastos de envío y devolución de componentes y escogerá la empresa de transporte que se utilice para dicho servicio.

Para obtener más información acerca del programa de Reparaciones del propio cliente de HP, póngase en contacto con su proveedor de servicios local. Si está interesado en el programa para Norteamérica, visite la página web de HP siguiente ( http://www.hp.com/go/selfrepair ).

Customer Self Repair

Veel onderdelen in HP producten zijn door de klant zelf te repareren, waardoor de reparatieduur tot een minimum beperkt kan blijven en de flexibiliteit in het vervangen van defecte onderdelen groter is. Deze onderdelen worden CSR-onderdelen (Customer Self Repair) genoemd. Als HP (of een HP Service Partner) bij de diagnose vaststelt dat de reparatie kan worden uitgevoerd met een CSR-onderdeel, verzendt HP dat onderdeel rechtstreeks naar u, zodat u het defecte onderdeel daarmee kunt vervangen. Er zijn twee categorieën CSR-onderdelen:

Verplicht: Onderdelen waarvoor reparatie door de klant verplicht is. Als u HP verzoekt deze onderdelen voor u te vervangen, worden u voor deze service reiskosten en arbeidsloon in rekening gebracht.

Optioneel: Onderdelen waarvoor reparatie door de klant optioneel is. Ook deze onderdelen zijn ontworpen voor reparatie door de klant. Als u echter HP verzoekt deze onderdelen voor u te vervangen, kunnen daarvoor extra kosten in rekening worden gebracht, afhankelijk van het type garantieservice voor het product.

OPMERKING: Sommige HP onderdelen zijn niet ontwikkeld voor reparatie door de klant. In verband met de garantievoorwaarden moet het onderdeel door een geautoriseerde Service Partner worden vervangen.

Deze onderdelen worden in de geïllustreerde onderdelencatalogus aangemerkt met "Nee".

Afhankelijk van de leverbaarheid en de locatie worden CSR-onderdelen verzonden voor levering op de eerstvolgende werkdag. Levering op dezelfde dag of binnen vier uur kan tegen meerkosten worden aangeboden, indien dit mogelijk is gezien de locatie. Indien assistentie gewenst is, belt u een HP Service

Partner om via de telefoon technische ondersteuning te ontvangen. HP vermeldt in de documentatie bij het vervangende CSR-onderdeel of het defecte onderdeel aan HP moet worden geretourneerd. Als het defecte onderdeel aan HP moet worden teruggezonden, moet u het defecte onderdeel binnen een bepaalde periode, gewoonlijk vijf (5) werkdagen, retourneren aan HP. Het defecte onderdeel moet met de bijbehorende documentatie worden geretourneerd in het meegeleverde verpakkingsmateriaal. Als u het defecte onderdeel niet terugzendt, kan HP u voor het vervangende onderdeel kosten in rekening brengen.

Bij reparatie door de klant betaalt HP alle verzendkosten voor het vervangende en geretourneerde onderdeel en kiest HP zelf welke koerier/transportonderneming hiervoor wordt gebruikt.

Neem contact op met een Service Partner voor meer informatie over het Customer Self Repair programma van HP. Informatie over Service Partners vindt u op de HP website ( http://www.hp.com/go/selfrepair ).

Reparo feito pelo cliente

Os produtos da HP são projetados com muitas peças para reparo feito pelo cliente (CSR) de modo a minimizar o tempo de reparo e permitir maior flexibilidade na substituição de peças com defeito. Se, durante o período de diagnóstico, a HP (ou fornecedores/parceiros de serviço da HP) concluir que o reparo pode ser efetuado pelo uso de uma peça CSR, a peça de reposição será enviada diretamente ao cliente. Existem duas categorias de peças CSR:

Obrigatória – Peças cujo reparo feito pelo cliente é obrigatório. Se desejar que a HP substitua essas peças, serão cobradas as despesas de transporte e mão-de-obra do serviço.

Technical support 127

Opcional – Peças cujo reparo feito pelo cliente é opcional. Essas peças também são projetadas para o reparo feito pelo cliente. No entanto, se desejar que a HP as substitua, pode haver ou não a cobrança de taxa adicional, dependendo do tipo de serviço de garantia destinado ao produto.

OBSERVAÇÃO: Algumas peças da HP não são projetadas para o reparo feito pelo cliente. A fim de cumprir a garantia do cliente, a HP exige que um técnico autorizado substitua a peça. Essas peças estão identificadas com a marca "No" (Não), no catálogo de peças ilustrado.

Conforme a disponibilidade e o local geográfico, as peças CSR serão enviadas no primeiro dia útil após o pedido. Onde as condições geográficas permitirem, a entrega no mesmo dia ou em quatro horas pode ser feita mediante uma taxa adicional. Se precisar de auxílio, entre em contato com o Centro de suporte técnico da HP para que um técnico o ajude por telefone. A HP especifica nos materiais fornecidos com a peça CSR de reposição se a peça com defeito deve ser devolvida à HP. Nos casos em que isso for necessário, é preciso enviar a peça com defeito à HP dentro do período determinado, normalmente cinco (5) dias úteis. A peça com defeito deve ser enviada com a documentação correspondente no material de transporte fornecido. Caso não o faça, a HP poderá cobrar a reposição. Para as peças de reparo feito pelo cliente, a HP paga todas as despesas de transporte e de devolução da peça e determina a transportadora/serviço postal a ser utilizado.

Para obter mais informações sobre o programa de reparo feito pelo cliente da HP, entre em contato com o fornecedor de serviços local. Para o programa norte-americano, visite o site da HP

( http://www.hp.com/go/selfrepair ).

Technical support 128

Technical support 129

Technical support 130

Acronyms and abbreviations

ABEND abnormal end

ACU

Array Configuration Utility

ADU

Array Diagnostics Utility

AMP

Advanced Memory Protection

ASR

Automatic Server Recovery

DDR double data rate

FBWC flash-backed write cache

IEC

International Electrotechnical Commission iLO

Integrated Lights-Out

IML

Integrated Management Log

KVM keyboard, video, and mouse

LV DIMM

Low voltage DIMM

Acronyms and abbreviations 131

NMI non-maskable interrupt

NVRAM non-volatile memory

ORCA

Option ROM Configuration for Arrays

PCIe peripheral component interconnect express

PCI-X peripheral component interconnect extended

PDU power distribution unit

POST

Power-On Self Test

PSP

ProLiant Support Pack

RBSU

ROM-Based Setup Utility

RDIMM

Registered Dual In-line Memory Module

RDP

Rapid Deployment Pack

SAS serial attached SCSI

SATA serial ATA

SIM

Systems Insight Manager

Acronyms and abbreviations 132

SMP

Server Migration Pack

TPM trusted platform module

UDIMM

Unregistered Dual In-Line Memory Module

UID unit identification

USB universal serial bus

VCA

Version Control Agent

Acronyms and abbreviations 133

Index

A

access panel 21, 22

additional information 96

ADU (Array Diagnostic Utility) 92

air baffle 22 air baffle, configuring 22

airflow requirements 28, 29

Altiris Deployment Solution 88

Altiris eXpress Deployment Server 88

Array Diagnostic Utility (ADU) 92

ASR (Automatic Server Recovery) 88

authorized reseller 123

auto-configuration process 85

Automatic Server Recovery (ASR) 88

B

Basic Input/Output System (BIOS) 86, 89, 101

batteries, replacing 117 battery 13, 112, 117 battery replacement notice 117

BBWC (battery-backed write cache) 68

BBWC battery pack 68

beep codes 111

bezel blank 24

BIOS (Basic Input/Output System) 86, 89, 101

BIOS Serial Console 86

BIOS upgrade 89

blue screen event 13

boot options 86

BSMI notice 116

buttons 7

C

cables 78, 99, 114

cabling 78, 79, 80, 81, 82, 83

Canadian notice 115

capacitor pack 70

Care Pack 28, 95

cautions 97

Change Control 94

Chinese notice 117

class A equipment 113 class B equipment 113

components 7

components, identification 7, 13

configuration of system 84 configuration tools 84

connection problems 99

connectors 7

contact information 123 contacting HP 123

crash dump analysis 13

creating a disk image 88

CSR (customer self repair) 123 customer self repair (CSR) 123

D

Declaration of Conformity 114

dedicated iLO 2 connector module 73 dedicated iLO 2 module connector 73

deployment software 88

device numbers 17

diagnosing problems 96

diagnostic tools 88, 89, 91 diagnostics utility 91

DIMM installation guidelines 43

DIMM slot locations 15

DIMMs 15, 40, 41, 86

diskette image creation 88

disposal, battery 115, 117

drive LEDs 18

drivers 93

E

electrical grounding requirements 30

electrostatic discharge 119

environmental requirements 28

environmental specifications 120

Erase Utility 89

error messages 111

European Union notice 115

expansion boards 63, 64 expansion slot covers, removing 63, 64

extending server from rack 21

Index 134

F

fan module locations 19

fans 19, 50

FBWC module 70

FCC rating label 113

features 7

Federal Communications Commission (FCC)

notice 113, 114

flowcharts 100, 101, 103, 106, 107, 109

front bezel 20

front panel buttons 8

front panel components 7

front panel LEDs 8, 14

full-height media device 61 full-height tape drive 61

G

general diagnosis flowchart 101

grounding methods 119

grounding requirements 30

guide screws 58

H

half-height media device 58, 60

hard drive cage 53, 55

hard drive LEDs 18

hardware options 35 hardware options installation 31, 35

health driver 88

health LEDs 13, 14

heatsink 35

help resources 123

hot-plug hard drive cage 53

HP Insight Diagnostics 91, 92

HP Insight Remote Support software 93

HP Insight Server Migration Pack software for

ProLiant 92

HP Management Packs 1.1 for MOM 2005,

troubleshooting 96

HP ProLiant Essentials Foundation Pack 90

HP ProLiant Essentials Rapid Deployment Pack 88

HP Systems Insight Manager overview 90

HP technical support 123

I

identification number 113

iLO (Integrated Lights-Out) 89 iLO 2 (Integrated Lights-Out 2) 89

IML (Integrated Management Log) 92

Important Safety Information document 96

Insight Diagnostics 91, 92, 93

installation services 28

installation, server options 31, 35 installing hardware 35

installing operating system 34

Integrated Lights-Out (iLO) 89

Integrated Lights-Out 2 (iLO 2) 89

Integrated Management Log (IML) 92

internal health LED 14

internal USB functionality 91

J

Japanese notice 116

K

Korean notices 117

L

laser compliance 117 laser devices 117

LEDs 7, 14

LEDs, hard drive 18

LEDs, SAS hard drive 18

LEDs, troubleshooting 14, 18, 96

loose connections 99

M

Management Agents 90

management tools 88

mechanical specifications 120

media bay blank 23

media devices 57

memory 40, 41, 43, 86, 87

memory configurations 41, 42, 43

memory subsystem architecture 41

memory, installing 47

memory, mirrored 43, 45, 46

modifications, FCC notice 114

N

NMI switch 13

non-hot-plug hard drive cage 55

O

operating systems 94

Index 135

operations 20

optimum environment 28

Option ROM Configuration for Arrays (ORCA) 87

options installation 31, 35

ORCA (Option ROM Configuration for Arrays) 87

OS boot problems flowchart 107

P

PCI slots 20

PCI-X extender board 65

PCI-X extender board connector 11

phone numbers 123

POST error messages 111

POST problems flowchart 106

power cord 97, 118

power distribution unit (PDU) 30

Power On/Standby button 20

power requirements 30

power supplies 48, 49 power supply configuration 49

power supply specifications 121

powering down 20

powering up 20, 85

power-on problems flowchart 103

pre-diagnostic steps 96

preparation procedures 20, 99

problem diagnosis 96

processor board, installing 25

processor board, removing 24

processors 35

ProLiant Support Pack (PSP) 94

PSPs, overview 94

R

rack installation 28, 30, 32

rack resources 28

rack stability 97 rack warnings 30, 97

RBSU (ROM-Based Setup Utility) 85

RBSU configuration 85

rear panel buttons 10

rear panel components 9

rear panel LEDs 10

redundant ROM 90

registering the server 34

regulatory compliance identification numbers 113

regulatory compliance notices 113, 115, 118

remote support and analysis tools 93

removable media devices 58, 60, 61

required information 123

requirements, airflow 28 requirements, environmental 28

requirements, power 30

requirements, space 28

requirements, temperature 29

ROM redundancy 90

ROM-Based Setup Utility (RBSU) 77, 85

ROMPaq utility 89, 90

S

safety considerations 30, 96

safety information 91

SAS controller 72

SAS device numbers 17

SAS hard drive 52

SAS hard drive LEDs 18

SATA drives 17

SATA hard drive 52

SATA hard drive LEDs 18

SATA optical drive 58

scripted installation 84

serial number 88

series number 113

server fault indications flowchart 109

server features and options 35 server options, installing 31, 35

service notifications 100

shipping carton contents 31

site requirements 29

SmartStart autorun menu 84

SmartStart Scripting Toolkit 84

SmartStart, overview 84 software 84

space requirements 28

specifications 120, 121

specifications, environmental 120 specifications, mechanical 120

specifications, power supply 121

specifications, server 120

start diagnosis flowchart 100

static electricity 119

storage controller 68

StorageWorks Library and Tape Tools (L&TT) 90

support 93, 123

support packs 84

supported operating systems 94

switches 13

symbols on equipment 97

symptom information 98

Index 136

system battery 112

system board components 11

system board LEDs 13

system configuration settings 84

System Erase Utility 89

system maintenance switch 12, 13

System Online ROM flash component utility 94

system, keeping current 93

Systems Insight Manager 90

T

Taiwan battery recycling notice 118

tape drives 60, 61

technical support 123 telephone numbers 123

temperature requirements 29

tower bezel, removing 20

tower server, setting up 31

TPM (Trusted Platform Module) 11, 74, 75

troubleshooting 96

troubleshooting flowcharts 100

troubleshooting resources 96

Trusted Platform Module (TPM) 74, 76

U

updating the system ROM 90

UPS (uninterruptible power supply) 30

USB support 91

utilities 84

utilities, deployment 84, 85, 88

V

ventilation 28

W

warnings 30, 97

website, HP 123

Index 137

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement

Table of contents

Languages