Tatung R-091DYGN Air Conditioners Owner's Manual
Below you will find brief information for R-091DYGN. This document serves as a comprehensive owner's manual, guiding users through the safe operation, detailed features, and proper maintenance of their split air conditioner. It covers everything from remote control functions and display icons to installation instructions, troubleshooting common issues, and essential cleaning procedures, ensuring optimal performance and longevity for the appliance.
Advertisement
Advertisement
Q TATUNG
AIR CONDITIONER
Loe Е —— ——
OWNER'S MANUAL
Split Air Conditioner Avègres
Content
Read Before Operation
SC As 1
Name of Parts ................e..eeeecrcerccccrncoceceaceaeaceneeeateneacenesee acercara nee eee 6
Screen Operation Guide
Buttons on remote controller ............ reee eee eee 7
Introduction for icons on display screen .................e....r.ee=eeeeseeeeeeecene eee 7
Introduction for buttons on remote controller...........................eeeeeeereresere DA 8
Function introduction for combination buttons...................-.e-e......e. erre 12
Operation guide ……..…..….....….......….......….ccsresececenerracecenenrecee an aseee ce eaara crea rence mener 13
Replacement of batteries in remote controller... eevee, 13
Emergency Operation .............oo oii ener enn. 14
Maintenance
Clean and maintenance..................e..eeeeceesiiierrrcer rece eee eee eee eer eens 14
Troubleshooting
Malfunction analysiS .…….........…......rsreececeserracenanracre ne nene ee ee sance cena rence me nee nana 17
Installation Notice
Installation dimension diagraM ee near rene 21
Tools for installation .....................ee..eeeesieerneercieee eee eee re ere arce ereenacen eee. 22
Selection of installation location ......................—e..........ee0eeieeeer reee eee RDA 22
Requirements for electric connection... eee 23
Installation
Installation of indoor Unit........................eee2eeeesveeerriecencece rece eee reee eee. 24
Installation of outdoor Unit .....................e.eeeeesereercreerneeee ene arce ercer eee. 29
Vacuum pumping................ RS 32
Leakage detection .......... coor ea 32
Check after installation ……..................….....rrrccsrrncrnreeearreeaerenene en anea caen n aan caen cena e 33
Test and operation
Test operatiON ce sance rene care een eee aan 33
Attachment
Configuration of connection PIPE ...... coor iii e... =D. 34
Pipe expanding Method... een ere 36
Safety /
( N
Operation and Maintenance
*Children shall not play with the appliance.
eCleaning and user maintenance shall not be made by
children without supervision.
*Do not connect air conditioner to multi-purpose socket.
Otherwise, it may cause fire hazard.
eDo disconnect power supply when cleaning air
conditioner. Otherwise, it may cause electric shack.
*|f the supply cord is damaged, it must be replaced by
the manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
*Do not wash the air conditioner with water to avoid
electric shock.
*Do not spray water on indoor unit. It may cause electric
shock or malfunction.
eAfter removing the filter, do not touch fins to avoid injury.
*Do not use fire or hair dryer to dry the filter to avoid
deformation or fire hazard.
Safety /
( N
e Do not repair air conditioner by yourself. It may cause
electric shock or damage. Please contact dealer when
you need to repair air conditioner.
e Do not extend fingers or objects into air inlet or air
outlet. It may cause personal injury or damage.
e Do not block air outlet or air inlet. It may cause
malfunction.
e Do not spill water on the remote controler, otherwise the
remote controller may be broken.
* When below phenomenon occurs, please turn off air
conditioner and disconnect power immediately, and then
contact the dealer or qualified professionals for service.
- Power cord is overheating or damaged.
+ There's abnormal sound during operation.
. Circuit break trips off frequently.
. Air conditioner gives off burning smell.
. Indoor unit is leaking.
e |f the air conditioner operates under abnormal conditions,
it may cause malfunction, electric shock or fire hazard.
* When turning on or turning off the unit by emergency
operation switch, please press this switch with an insulating
object other than metal.
* Do not step on top panel of outdoor unit, or put heavy
objects. It may cause damage or personal injury.
Safety /
Attachment
e Installation must be performed by qualified professionals.
Otherwise, it may cause personal injury or damage.
e Must follow the electric safety regulations when installing
the unit.
* According to the local safety regulations, use qualified
power supply circuit and circuit break.
Do install the circuit break. If not, it may cause malfunction.
e An all-pole disconnection switch having a contact separation
of at least 3mm in all poles should be connected in fixed
wiring.
e Including a circuit break with suitable capacity, please
note the following able: Air switch should be included with
magnet buckle and heating buckle function, it can protect
the circuit-short and overload.
e Air Conditioner should be properly grounded. Incorrect
grounding may cause electric shock.
* Don't use unqualified power cord.
e Make sure the power supply matches with the
requirement of air conditioner.Unstable power supply or
Incorrect wiring or malfunction. Please install proper power
supply cables before using the air conditioner.
~
e Properly connect the live wire, neutral wire and
grounding wire of power socket.
* Be sure to cut off the power supply before proceeding
u any work related to electricity and safety.
J
3
Safety /
( N
e Do not put through the power before finishing installation.
* The temperature of refrigerant circuit will be high, please
keep the interconnection cable away from the copper
tube.
* The appliance shall be installed in accordance with
national wiring regulations.
e Installation must be performed in accordance with the
requirement of NEC and CEC by authorized personnel
only.
* The yellow-green wire in air conditioner is grounding
wire, which can't be used for other purposes.
e The grounding resistance should comply with national
electric safety regulations.
* The appliance must be positioned so that the plug is
accessible.
* All wires of indoor unit and outdoor unit should be
connected by a professional.
* |f the length of power connection wire is insufficient, please
contact the supplier for a new one. Avoid extending the
wire by yourself.
Safety /
( N
e For air conditioners with plug, the plug should be
reachable after finishing installation.
e For air conditioners without plug, a circuit break
must be installed in the line.
e If you need to relocate the air conditioner to another
place, only the qualified person can perform the work.
Otherwise, it may cause personal injury or damage.
* Select a location which is out of reach for children and
far away from animals or plants. If it is unavoidable,
please add fence for safety purpose.
u The indoor unit should be installed close to the wall.
Working temperature range
Indoor side DB/WB(C) Outdoor side DB/WB(C)
Maximum cooling 26.7/19.4 46.1/23.9
Maximum heating 26. 7/- 23.9/18.3
Indoor side DB/WB(*F ) Outdoor side DB/WB( °F)
Maximum cooling 80.06/66.92 114.98/75.02
Maximum heating 80.06/- 75.02/64.94
NOTICE:
e The operating temperature range (outdoor temperature) is -18 C~46.1C
(-0.4F-114.9F).
Name of Parts /
EGO air inlet
panel
filter
= aux.button
r J
== Es Ll =
€ ZÉ Q Á >
\ Noon louver
air outlet
cooling power receiver
indicator indicator window
У
| display
| |
Xx x* 6 db «a
| | |
heating temp. drying
indicator indicator indicator
(Display content or position may be different from above
graphics, please refer to actual products) remote controller
N
R-091DYGN
air inlet
Connection wire
air outlet
4
NOTICE:
Actual product may be different from above graphics, please refer to actual
products.
Buttons on remote controller /
7 3
>
>
7
OPER
* OF
s UD -
© 98-8645
“1: SE 0% a
FAN
*
>.
-
*
o-
AS
N
ON/OFF
999999 ¢
0
=)
ee)
TURBO SLEEP
| TIMER ON |
LIGHT
_ Y
@ ON/OFF button
@ MODE button
© +/- button
@ FAN button
© Sl button
@ CLOCK button
TIMER ON/TIMER OFF
button
X-FAN button
Note: X-FAN is the same with BLOW
O TEMP button
(M TURBO button
@ LIGHT button
(P SLEEP button
Introduction for icons on display screen /
OPUS Set fan speed
- 7 / ~
Operation mode \ /N FAN pr Send signal
i AT Tm _—
| Auto mode - - --H se / «=» «= X-fan mode
| Cool mode ----L--7 Le | И F
| D | 6 - Ee, Sett t
ry mode -------/-4 6 | i | ; et temperature
: Fanmode-----l (n| = == С
| 7m Ps =-------- --- Turbo mode
| Heat mode----L- no - --Set time
\ - Xx O 06:00
o fr == == "S_L__.TIMER ON / TIMER OFF
Clock---—"1
* | M1 NV N : SS lb Chi
Sleep mode------ С ae 7 © E |) Cob lock
NT |
| Aiea Up & down swing
—_—— - - Temp. display type — — — — .
| A Set temp. 0 Indoor ambient temp.
Г 5 :Outdoor ambient temp. J
—— a а.
Introduction for buttons on remote controller/
Note:
e After plugging inthe power, the air conditioner will give out a sound.
Operation indictor "(|)" is ON (red indicator). After that, you can operate the air
conditioner by using remote controller.
ON/OFF button
Press this button can turn on or turn off the air conditioner. After turning on the air
conditioner, operation indicator "(1)" on indoor unit's display is ON (green indicator.
The colour is different for different models), and indoor unit will give out a sound.
MODE button
Press this button to select your required operation mode.
AUTO COOL DRY FAN HEAT
COTE S XX >)
e When selecting auto mode, air conditioner will start auto operation according to
indoor ambient temperature. Set temperature can't be adjusted and will not
be displayed as well. Press "FAN" button can adjust fan speed.
Press " 31 " button can adjust fan blowing angle.
e After selecting cool mode, air conditioner will operate under cool mode. Cool
indicator "3" on indoor unit is ON. Press "+" or "-" button to adjust set tempe-
rature. Press "FAN" button to adjust fan speed. Press * 3 " button to adjust fan
blowing angle.
e When selecting dry mode, the air conditioner operates at low speed under dry
mode. Dry indicator " %" on indoor unit is ON. Under dry mode, fan speed can't
be adjusted. Press " 31 " button to adjust fan blowing angle.
e Vhen selecting fan mode, the air conditioner will only blow fan, no cooling and
no heating. All indicators are OFF. Press "FAN" button to adjust fan speed. Press
" 31 " button to adjust fan blowing angle.
e Vhen selecting heating mode, the air conditioner operates under heat mode.
Heat indicator " Y € " on indoor unit is ÓN. Press "+" or "-" button to adjust set
temperature. Press "FAN" button to adjust fan speed. Press * 1 " button to adjust
fan blowing angle. (Cooling only unit won't receive heating mode signal. If setting
heat mode with remote controller, press ON/OFF button can’t start up the unit).
Note:
e To prevent cold air, after starting up heating mode, the unit will delay 1-5
minutes to blow air (actual delay time is depend on indoor ambient temperature).
e Set temperature range from remote controller:16-30'C (60.8~86°F) ; Fan speed:
auto, low speed, medium speed. high speed.
8
Introduction for buttons on remote controller/
+/- button
e Press "+" or "-" button once increase or decrease set temperature 1°C (1.8°F) .
Holding "+" or "-" button, 2s later, set temperature on remote controller will
change quickly. On releasing button after setting is finished, temperature indica-
tor on indoor unit will change accordingly. (Temperature can’t be adjusted under
auto mode)
e \When setting TIMER ON, TIMER OFF or CLOCK, press "+" or "-" button to
adjust time. (Refer to CLOCK, TIMER ON, TIMER OFF buttons) When setting
TIMER ON, TIMER OFF or CLOCK, press "+" or "-" button to adjust time. (Refer
to CLOCK, TIMER ON, TIMER OFF buttons)
FAN button
Pressing this button can set fan speed circularly as: auto (AUTO), low( 4), medium
(dt), high( af).
(TAT — MM a 1 5
Note:
e Under AUTO speed, the IDU fan motor will adjust the fan speed (high, medium or
low speed) according to ambient temperature.
e Fan speed under dry mode is low speed.
31 button
Press this button can select up&down swing angle. Fan blow angle can be selected
circularly as below:
ae — \ — > — -] — I
no display «— >] «—3]«— A— J
(horizontal louvers stops
at current position)
e When selecting " 31 ", air conditioner is blowing fan automatically. Horizontal
louver will automatically swing up & down at maximum angle.
e When selecting * J. E. -1- .1- 1", air conditioner is blowing fan at fixed
position. Horizontal louver will stop at the fixed position.
e \When selecting " =. 3 71" , air conditioner is blowing fan at fixed angle.
Horizontal louver will send air at the fixed angle.
e Hold "MN" button above 2s to set your required swing angle. When reaching your
required angle, release the button.
Note:
e "1551" may not be available. When air conditioner receives this signal, the
air conditioner will blow fan automatically.
9
Introduction for buttons on remote controller/
M} CLOCK button
Press this button to set clock time. "ED" icon on remote controller will blink. Press
"+" or "-" button within 5s to set clock time. Each pressing of "+" or "-" button, clock
time will increase or decrease 1 minute. If hold "+" or "-" button, 2s later, time will
change quickly. Release this button when reaching your required time. Press
"CLOCK" button to confirm the time. "€" icon stops blinking.
Note:
e Clock time adopts 24-hour mode.
e The interval between two operation can't exceeds 5s. Otherwise, remote contro-
ller will quit setting status. Operation for TIMER ON/TIMER OFF is the same.
TIMER ON / TIMER OFF button
e TIMER ON button
"TIMER ON" button can set the time for timer on. After pressing this button, " On
icon disappears and the word "ON" on remote controller blinks. Press "+" or "-"
button to adjust TIMER ON setting. After each pressing "+" or "-" button, TIMER
ON setting will increase or decrease 1min. Hold "+" or "-" button, 2s later, the
time will change quickly until reaching your required time.
Press "TIMER ON" to confirm it. The word "ON" will stop blinking. "BD" icon
resumes displaying. Cancel TIMER ON: Under the condition that TIMER ON is
started up, press "TIMER ON" button to cancel it.
e TIMER OFF button
"TIMER OFF" button can set the time for timer off. After pressing this button," €5"
icon disappears and the word "OFF" on remote controller blinks. Press "+" or "-"
button to adjust TIMER OFF setting. After each pressing "+" or "-" button, TIMER
OFF setting will increase or decrease 1min. Hold "+" or "-" button, 2s later, the
time will change quickly until reaching your required time.
Press "TIMER OFF" word "OFF" will stop blinking. "(5)" icon resumes displaying.
Cancel TIMER OFF. Under the condition that TIMER OFF is started up, press
"TIMER OFF" button to cancel it.
Note:
e Under on and off status, you can set TIMER OFF or TIMER ON simultaneously.
e Before setting TIMER ON or TIMER OFF, please adjust the clock time.
e After starting up TIMER ON or TIMER OFF, set the constant circulating valid.
After that, air conditioner will be turned on or turned off according to setting time.
ON/OFF button has no effect on setting. If you don’t need this function, please
use remote controller to cancel it.
10
Introduction for buttons on remote controller/
E X-FAN button
Press this button under cool and dry mode to start up x-fan function, and "+ " icon
on remote controller will be displayed. Press this button again to cancel x-fan
function, and " 4 " icon will disappear.
Note:
e Vhen x-fan function is on, if the air conditioner is turned off, indoor fan will still
operate at low speed for a while to blow the residual water inside the air duct.
e During x-fan operation, press X-FAN button to turn off x-fan function. Indoor fan
Will stop operation immediately.
[2] тЕМР button
By pressing this button, you can see indoor set temperature, indoor ambient temp-
erature or outdoor ambient temperature on indoor unit's display. The setting on
remote controlleris selected circularly as below:
Care A
e When selecting "7 “ or no display with remote controller, temperature indicator
on indoor unit displays set temperature.
e When selecting "a" with remote controller, temperature indicator on indoor unit
displays indoor ambient temperature.
e When selecting "Са" with remote controller, temperature indicator on indoor unit
displays outdoor ambient temperature.
Note:
e Outdoor temperature display is not available for some models. At that time, indoor
unit receives " |_|" signal, while it displays indoor set temperature.
e |t's defaulted to display set temperature when turning on the unit. There is no
display in the remote controller.
e Only for the models whose indoor unit has dual-8 display.
e VWhen selecting displaying of indoor or outdoor ambient temperature, indoor
temperature indicator displays corresponding temperature and automatically turn
to display set temperature after three or five seconds.
TURBO button
Under COOL or HEAT mode, press this button to turn to quick COOL or quick
HEAT mode. "63 " icon is displayed on remote controller. Press this button again
to exit turbo function and " 69" icon will disappear.
11
Introduction for buttons on remote controller/
SLEEP button
Under COOL, HEAT or DRY mode, press this button to start up sleep function.
"Œ" icon is displayed on remote controller. Press this button again to cancel sleep
function and " €*" icon will disappear.
LIGHT button
Press this button to turn off display light on indoor unit. " ху "icon on remote
controller disappears. Press this button again to turn on display light. " Ser "icon is
displayed.
Function introduction for combination buttons/
( Child lock function)
Press "+" and "-" simultaneously to turn on or turn off child lock function. When
child lock function is on, "My" icon is displayed on remote controller. If you operate
the remote controller, the "gg" icon will blink three times without sending signal to
the unit.
( Temperature display switchover function )
Under OFF status, press "-" and "MODE" buttons simultaneously to switch temp-
erature display between C and °F" .
12
Operation Guide/
1. Plug in power cord, press "ON/OFF" button on remote controller to turn on
the air conditioner.
2. Press "MODE" button to select your required mode: AUTO, COOL, DRY, FAN,
HEAT.
3. Press "+" or "-" button to set your required temperature. (Temperature can’t be
adjusted under auto mode).
4. Press "FAN" button to set your required fan speed: auto, low, medium and high
speed.
5. Press "31" button to select fan blowing angle.
Replacement of batteries in remote controller/
@ >
1. Press the back side of remote controller marked signal sender battery
with "=", as shown in the fig, and then push out
the cover of battery box along the arrow direction. reinstall O°
2. Replace two 7# (AAA 1.5V) dry batteries, and
make sure the position of "+" polar and "-" polar Ya remove
| e
Cover of battery box —_)
are correct.
3. Reinstall the cover of battery box.
u
e During operation, point the remote control signal sender at the receiving
window on indoor unit.
e The distance between signal sender and receiving window should be no
more than 8m (26.24 ft), and there should be no obstacles between them.
e Signal may be interfered easily in the room where there is fluorescent lamp
or wireless telephone; remote controller should be close to indoor unit during
operation.
e Replace new batteries of the same model when replacement is required.
e When you dont use remote controller for a long time, please take out the
batteries.
e |fthe display on remote controller is fuzzy or there's no display, please
_ replace batteries. )
13
Emergency Operation/
( ON
If remote controller is lost or damaged, please use auxiliary button to turn
on or turn off the air conditioner. The operation in details are as below:
As shown in the fig. Open panel, press aux. button to turn on or turn off the
air conditioner. When the air conditioner is turned on, it will operate under
auto mode.
aux. button
Os
N ”
Clean and Maintenance /
AN WARNING
m Turn off the air conditioner and disconnect the power before cleaning the air
conditioner to avoid electric shock.
x
m Do not wash the air conditioner with water to avoid electric shock.
\" Do not use volatile liquid to clean the air conditioner. D
( Clean surface of indoor unit )
When the surface of indoor unit is dirty, it is recommended to use a soft dry cloth
or wet cloth to wipe it.
NOTICE:
e Do not remove the panel when cleaning it.
14
Clean and Maintenance /
(Clean filter )
( Open panel dé Clean filter >
Pull out the panel to a certain 6) e Use dust catcher or water to
angle as shown in the fig. clean the filter.
e When the filter is very dirty, use
the water (below 45°C) to clean
it, and then put it in a shady
and cool place to dry.
N 7
Remove filter
Remove the filter as in- N J
dicated in the fig. 7
QA Install filter В
Install the filter and then close the
panel cover tightly.
N И NX ,
m The filter should be cleaned every three months. If there is much dust in the
operation environment, clean frequency can be increased.
A WARNING
m After removing the filter, do not touch fins to avoid injury.
m Do not use fire or hair dryer to dry the filter to avoid deformation or fire hazard.
15
Clean and Maintenance /
NOTICE: Checking before use-season
1. Check whether air inlets and air outlets are blocked.
2. Check whether circuit break, plug and socket are in good condition.
3. Check whether filter is clean.
4. Check whether mounting bracket for outdoor unit is damaged or corroded.
If yes, please contact dealer.
5. Check whether drainage pipe is damaged.
N J
NOTICE: Checking after use-season
1. Disconnect power supply.
2. Clean filter and indoor unit's panel.
3. Check whether mounting bracket for outdoor unit is damaged or corroded.
If yes, please contact dealer.
N J
Notice for recovery
1. Many packing materials are recyclable materials.
Please dispose them in appropriate recycling unit.
2. If you want to dispose the air conditioner, please contact local dealer or
consultant service center for the correct disposal method.
16
Troubleshooting /
General phenomenon analysis )
Please check below items before asking for maintenance. If the malfunction still
can't be eliminated, please contact local dealer or qualified professionals.
Problem Check items
Solution
voltage)?
e Whether remote controller is
Within the signal receiving
range?
Indoor unit
can't receive
remote
controller's
signal or
remote
controller
has no
action.
e Whether remote controller is
pointing at the receiving
window?
display?
e No display when operating
remote controller?
e Fluorescent lamp in room?
e Whether it's interfered severely e Pull out the plug. Reinsert D)
(such as static electricity,stable
e Whether there are obstacles?
e |s sensitivity of remote contro-
ller low ; fuzzy display and no
the plug after about 3min, and
then turn on the unit again.
e Signal receiving range is 8m
(260.241).
e Remove obstacles.
e Select proper angle and point
the remote controller at the re-
ceiving window on indoor unit.
e Check the batteries. If the
power of batteries is too low,
please replace them.
e Check whether remote cont-
roller appears to be damaged.
If yes, replace it.
e Take the remote controller
close to indoor unit.
e Turn off the fluoresent lamp
and then try it again. J
unit is blocked?
e Under heating mode, indoor
No air
emitted
from
temperature?
indoor
unit now?
e Air inlet or air outlet of indoor
temperature is reached to set
e Heating mode is turned on just e In order to prevent blowing
e Eliminate obstacles. D)
e After reaching to set temper-
ature, indoor unit will stop bl-
owing out air.
out cold air, indoor unit will be
started after delaying for sev-
eral minutes, which is a nor-
mal phenomenon. J
17
Troubleshooting /
Problem
Check items
Solution
Air condit-
joner can't
operate
Mist is em-
itted from
indoor unit's
air outlet
Set temper-
ature can't
be adjusted
Cooling
(heating)
effect is
not good.
e Power failure?
® |5 plug loose?
e Circuit break trips off or
fuse is burnt out?
e Wiring has malfunction?
e Unit has restarted immediately
after stopping operation?
e Whether the function setting
for remote controller is
correct?
e Wait until power recovery. D)
e Reinsert the plug.
e Ask professional to replace
circuit break or fuse.
e Ask professional to replace it.
e Wait for 3min, and then turn
on the unit again.
e Reset the function.
e Indoor temperature and hum-
idity is high?
e Because indoor air is cooled
rapidly. After a while, indoor
temperature and humidity will
be decrease and mist will
disappear.
e Unit is operating under auto
mode?
e Your required temperature
exceeds the set temperature
range?
e Temperature cant be adju- N
sted under auto mode.
Please switch the operation
mode if you need to adjust
temperature.
e Set temperature range:
16 C-30C (60.8-86F) . J
e Voltage is too low?
e Filter is dirty?
e Set temperature is in proper
range?
e Door and window are open?
18
>
e Wait until the voltage
resumes normal.
e Clean the filter.
e Adjust temperature to proper
range.
e Close door and window.
J
Troubleshooting /
Problem Check items Solution
e Whether there's odors source,
such as furniture and cigarette,
etc.
Odors are e Eliminate the odors source.
emitted e Clean the filter.
Air conditio-
ner operates
abnormally
e Disconnect power, put back
power, and then turn on the
unit again.
e Whether there's interference,
such as thunder, wireless
devices, etc.
Outdoor
unit has
vapor
“Waterf
flowing"
noise
Cracking
noise
e Heating mode is turned on?
e During defrosting under he-
ating mode, it may generate
vapor, which is a normal
phenomenon.
e Air conditioner is turned on or
turned off just now?
e The noise is the sound of
refrigerant flowing inside
the unit, which is a normal
phenomenon.
e Air conditioner is turned on or
turned off just now?
e This is the sound of friction
caused by expansion and/or
contraction of panel or other
parts due to the change of
temperature.
88 7 об ВА т)
19
Troubleshooting /
( Error Code )
e When air conditioner status is abnormal, temperature indicator on indoor unit will
blink to display corresponding error code. Please refer to below list for identific-
ation of error code.
Above indicator diagram is only
Xx % ES © «a {Indoor for reference. Please refer to
| display J actual product for the actual
Error code indicator and position.
Error code Troubleshooting
Heating indicator
ON 10s OFF 0.5s
ES
H6
C5
F1
F2
E6
Note: If there're other error codes, please contact qualified professionals for
service.
E When below phenomenon occurs, please turn off air conditioner and discon-
nect power immediately, and then contact the dealer or qualified professionals
for service.
e¢ Power cord is overheating or damaged.
e There's abnormal sound during operation.
e Circuit break trips off frequently.
e Air conditioner gives off burning smell.
e Indoor unit is leaking.
H Do not repair or refit the air conditioner by yourself.
H If the air conditioner operates under abnormal conditions, it may cause
\ malfunction, electric shock or fire hazard. y
Installation dimension diagram/
ce to the c
(5.9 in)
Spa
| Space to the wall
o
(5.9in), IT FL E
(Atleast 15cm> EELLECI A
AN NN NN IS TS IS IN = (5.9 in)
/ Г C
Y Zr
3 7
= A
2 A
o il =
2 Ц
D —
= Г
>
5 -
в
|
>
в
|
|
<>
”
—
5 |
©
5 В,
2 y” Е 2
o ©
7
\
Space-to
NN
At least 50cm) (19.68 in)
LLL \
(19.68 in)
At least 50cm
Space to the
7 obstruction
- LJ . .
a Drainage pipe
>
21
Tools for Installation /
1 Level meter 2 Screw driver 3 Impact drill
4 Drill head 5 Pipe expander 6 Torque wrench
7 Open-end wrench 8 Pipe cutter 9 Leakage detector
10 Vacuum pump 11 Pressure meter 12 Universal meter
| 13 Inner hexagon spanner 14 Measuring tape J
ACID e Please contact the local agent for installation. )
e Dont use unqualified power cord.
\_
Selection of installation location/
Basic requirement Indoor unit
Installing the unit in the following pla- | 1. There should be no obstruction near air
ces may cause malfunction. If itis un-| inlet and air outlet.
avoidable, please consult the local 2. Select a location where the condensat-
dealer: ion water can be dispersed easily and
1.The place with strong heat sources,| won't affect other people.
vapors, flammable or explosive gas, | 3. Select a location which is convenient to
or volatile objects spread in the air. connect the outdoor unit and near the
2.The place with high-frequency power socket.
devices (such as welding machine, |4. Select a location which is out of reach
medical equipment). for children.
3.The place near coast area. 5. The location should be able to withstand
4.The place with oil or fumes in the air. the weight of indoor unit and won't incr-
5.The place with sulfureted gas. ease noise and vibration.
6.Other places with special circums- |6. The appliance must be installed 8.2 ft
tances. above floor.
7.Do not use the unit in the immediate| 7. Don't install the indoor unit right above
surroundings of a laundry a bath a the electric appliance.
shower or a swimming pool. 8. Please try your best to keep way from
fluorescent lamp.
Outdoor unit
1. Select a location where the noise and outflow air emitted by the outdoor unit
Will not affect neighborhood.
2. The location should be well ventilated and dry, in which the outdoor unit
won't be exposed directly to sunlight or strong wind.
3. The location should be able to withstand the weight of outdoor unit.
4. Make sure that the installation follows the requirement of installation
dimension diagram.
5. Select a location which is out of reach for children and far away from animals
\_ or plants. If it is unavoidable, please add the fence for safety purpose. ,
22
Requirements for Electric Connection /
(
1.
Safety Precaution )
Must follow the electric safety regulations when installing the unit.
2. According to the local safety regulations, use qualified power supply circuit and
3.
9.
circuit break.
Make sure the power supply matches with the requirement of air conditioner.
Unstable power supply or incorrect wiring or malfunction. Please install proper
power supply cables before using the air conditioner.
. Properly connect the live wire, neutral wire and grounding wire of power socket.
. Be sure to cut off the power supply before proceeding any work related to
electricity and safety.
. Do not put through the power before finishing installation.
. If the supply cord is damaged, it must be replaced by the manufacturer, its
service agent or similarly qualified persons in order to avoid a hazard.
. The temperature of refrigerant circuit will be high, please keep the interconnec-
tion cable away from the copper tube.
The appliance shall be installed in accordance with national wiring regulations.
10. Installation must be performed in accordance with the requirement of NEC
and CEC by authorized personnel only.
(Grounding requirement)
1.
2.
3.
4.
The air conditioner is the first class electric appliance. It must be properly
grounding with specialized grounding device by a professional. Please make
sure it is always grounded effectively, otherwise it may cause electric shock.
The yellow-green wire in air conditioner is grounding wire, which can't be used
for other purposes.
The grounding resistance should comply with national electric safety regulations.
The appliance must be positioned so that the plug is accessible.
5. An all-pole disconnection switch having a contact separation of at least 3mm in
6.
all poles should be connected in fixed wiring.
Including an circuit break with suitable capacity, please note the following table.
Circuit break should be included magnet buckle and heating buckle function, it
can protect the circuit-short and overload. (Caution: please do not use the fuse
only for protect the circuit)
( Air-conditioner | Air switch capacity)
09K 35A
1% BA
23
Installation of Indoor Unit /
Step One: Choosing installation location
Recommend the installation location to the client and then confirm it with the client.
Step Two: Install wall-mounting frame
1. Hang the wall-mounting frame on the wall; adjust it in horizontal position with the
level meter and then point out the screw fixing holes on the wall.
2. Drill the screw fixing holes on the wall with impact drill (the specification of drill
head should be the same as the plastic expansion particle) and then fill the
plastic expansion particles in the holes.
3. Fix the wall-mounting frame on the wall with tapping screws (ST4.2X25TA) and
then check if the frame is firmly installed by pulling the frame. If the plastic
expansion particle is loose, please drill another fixing hole nearby.
Step Three: Open piping hole
1. Choose the position of piping hole according to the direction of outlet pipe. The
position of piping hole should be a little lower than the wall-mounted frame,
shown as below.
f NN
Wall Wall
\ space Sn in the = of it > — Level meter Space x
\ he SZ. = ‘to he
wa wa
\ above above
ems e U Il A
®55mm(2.16in) © I I I o somm(2.16 in)
q (Rear piping hole) (Rear piping hole) |
2. Open a piping hole with the diameter of ®55mm(2.16 in) or P 70mM(2.75 in)
on the selected outlet pipe position. In order to drain smoothly, slant the piping
hole on the wall slightly downward to the outdoor side with the gradient of
5~10°.
24
Installation of Indoor Unit /
Indoor outdoor
Note:
e Pay attention to dust prevention and
take relevant safety measures when
opening the hole. |
e The plastic expansion particles are о Ф55/
not provided and should be bought 5-10 P70
locally.
N J
Step Four: Outlet pipe
1. The pipe can be led out in the I 2. When select leading out the pipe
direction of right, rear right, left or | from left or right, please cut off the
rear left. | corresponding hole on the bottom
| case.
| left right
|
|
rear left N cut off
| 4 the hole E
Step Five: Connect the pipe of indoor unit
1. Aim the pipe joint at the corresponding ______ > <) —
bellmouth. ОЗ 7
pipe joint union nut Pipe
2. Pretightening the union nut with hand.
3. Adjust the torque force by referring to the following sheet. Place the open-end
wrench on the pipe joint and place the torque wrench on the union nut. Tighten
the union nut with torque wrench.
25
Installation of Indoor Unit /
t X Hex nut diameter| Tightening torque (N-m) |
open-end =
wrench ®6(1/4") 15-20
union nut $9.52(3/8") 30~40
Ф12(1/2") 45-55
torque weneh__ (q > PP® | Ф16(5/8") 60-65
= [1903/47 70-75 7
indoor pipe
4. Wrap the indoor pipe and joint of con-
nection pipe with insulating pipe, and
then wrap it with tape. insulating pipe
Step Six: Install drain hose
1. Connect the drain hose to the outlet pipe of
indoor unit.
drain hose
outlet pipe
2. Bind the joint with tape.
т КРУ
UD
tape
Note: drain hose
e Add insulating pipe in the indoor NNN к
drain hose in order to prevent ) | | | | | | |
condensation.
|
e The plastic expansion particles are
not provided. insulating pipe
Step Seven: Connect wire of indoor unit
panel screw
1. Open the panel, remove the screw
on the wiring cover and then take
down the cover.
wiring cover
26
Installation of Indoor Unit /
2. Make the power connection cord go
through the cable-cross hole at the back
of indoor unit and then pull it out from
the front side.
3. Remove the wire clip; connect the power connection cord to the wiring terminal
according to the color ; tighten the screws and then fix the power connection cord
With wire clip.
If there is no wired controller in the product you bought ,you should put the wire
fixed by the wire clip inside of the electric box first before connecting the power
connection cord.
( N
[№2 | з | © |
— |
LA
[ I Î | - ss 1
= | | N L | © |
|
= ı INC) 2 [3D]
№ о к к ое ее = = == = — —
| Outdoor unit connection J
4. Put wiring cover back and then tighten the screw.
5. Close the panel.
Note:
e All wires of indoor unit and outdoor unit should be connected by a professional.
e If the length of power connection cord is insufficient, please contact the supplier
for a new one. Avoid extending the cord by yourself.
e For the air conditioner with plug, the plug should be reachable after finishing
installation.
e For the air conditioner without plug, an circuit break must be installed in the line.
The air switch should be all-pole parting and the contact parting distance should
be more than 3mm (0.11 inch).
27
Installation of Indoor Unit /
Step Eight: Bind up pipe
1. Bind up the connection pipe, power
cord and drain hose with the band.
joepps!boe
pvuepps!qpxfs!dpse
£ SN Te
2. Reserve a certain length of drain
hose and power cord for installation
when binding them. When binding to
a certain degree, separate the indoor
power and then separate the drain
hose.
| dpoofdujpolajaf
joepps!agpxfs!dpse
4. The liquid pipe and gas pipe should
[
|
| 3. Bind them evenly.
| be bound separately at the end.
Note:
e The power cord and control wire
can’t be crossed or winding.
| ÿ ® The drain hose should be bound
I at the bottom.
Step Nine: Hang the indoor unit
1. Put the bound pipes in the wall pipe and then make them pass through the wall
hole.
2. Hang the indoor unit on the wall-mounting frame.
3. Stuff the gap between pipes and wall hole with sealing gum.
4. Fix the wall pipe.
5. Check if the indoor unit is installed firmly and closed to the wall.
joepps pvueprs
tfomjoh!hvn
(77
(=
mpxfs!ippl!pg
xbmm.npvoujoh!gsBn
т
Note:
| Do not bend the drain hose too excessively in order to prevent blocking.
28
Installation of Outdoor Unit /
Step One: Fix the support of outdoor unit
(select it according to the actual installation situation)
1. Select installation location according to the house structure.
2. Fix the support of outdoor unit on the selected location with expansion screws.
Note:
Take sufficient protective measures when
installing the outdoor unit.
e Make sure the support can withstand at least
four times of the unit weight.
e The outdoor unit should be installed at least
3cm above the floor in order to install drain
joint.
e For the unit with cooling capacity of 2300W
~5000W, 6 expansion screws are needed;
for the unit with cooling capacity of 6000W
~8000W, 8 expansion screws are needed;
for the unit with cooling capacity oí 10000W at least 3cm(1.18 in) above the floor
~16000W, 10 expansion screws are needed.
и
Step Two: Install drain joint | Step Three: Fix outdoor unit
(Only for cooling and heating ! 1. Place the outdoor unit on the
unit) | support.
1. Connect the outdoor drain joint into | 2 Fix the foot holes of outdoor unit
the hole on the chassis, as shown in | with bolts.
the picture below. I foot holes
2. Connect the drain hose into the drain
vent. | = =
|
Е
[ - + -
|
| A
Ez |
drain vent—- chassis | foot holes
outdoor drain joint
Drain hose и hn Jol |
Installation of Outdoor Unit /
Step Four: Connect indoor and outdoor pipes
1. Remove the screw on the right han- lI 3. Pretightening the union nut with
dle of outdoor unit and then remove [ hand.
the handle. |
[
— |
|
2. Remove the screw cap of valve and | 4. Tighten the union nut with torque
aim the pipe joint at the bellmouth of | wrench by referring to the sheet
PIPE. | below.
/ liquid pipe | (Hex nut diameter TE jorque °
liquid gas pipe D6(1/4") 15~20
valve | | ®9.52(3/8") 30-40
BN | Ф12(1/2") 45-55
| | ®16(5/8") 60-65
> gas va ve USE 70-75
Step Five: Connect Outdoor electric wire
1. Remove the wire clip; connect the power connection cord and power cord
to the wiring terminal according to the color; fix them with screws.
OUTDOOR UNIT
N(1)| 2 | 3 G LN
N L
power
1 Lo cord
power
| connection
= cord
|
| [Ney] 2 | 3 | |
|
| INDOOR UNIT
0/0
30
Installation of Outdoor Unit /
2. Fix the power connection cord and power cord with wire clip.
Note:
* After tighten the screw,pull the power cord and power connection cord slightly
to check if they are firm.
* Never cut the power connection cord to prolong or shorten the distance.
a
Step Six: Neaten the pipes
1. The pipes should be placed along the wall,
bent reasonably and hidden possibly. Min.
a
semidiameter of bending the pipe is 10cm. E
E I
2. If the outdoor unit is higher than the wall Я ve
hole, you must set a U-shaped curve in the Я
pipe before pipe goes into the room, in À
order to prevent rain from getting into the U-shaped cûrve
room.
drain hose
( в
Note:
e The through-wal height of drain hose e Slant the drain hose slightly dow-
shouldn’t be higher than the outlet nwards. The drain hose can’t be
pipe hole of indoor unit. curved, raised and fluctuant, etc.
the drain h
У X | ania SI
upwards.
| — — A
| ]
x The drain hose can't be fluctuant
e The water outlet can't be placed
in water in order to drain smoothly.
Xx The drain hose
can't be fluctuant
к
X
The water
outlet can't be
fluctuant
The water outlet
can't be placed__ 7= „ра
in water
31
Vacuum Pumping /
( Use vacuum pump )
1.
Leakage Detection /
gas valv
gerant charging vent.
. Connect the charging hose refrigerant valve cap
charging vents
. Open the piezometer com-
. Close the vacuum pump
Remove the valve caps on
the liquid valve and gas liquid valve piezometer
valve and the nut of refri- N
= (5) WN)
=
of piezometer to the refri-
gerant charging vent of gas nut of refrigerant
valve and then connect the ~~ charging vent
other charging hose to the “ZA —
vacuum pump.
vacuum pump
pletely and operate for inner hexagon
10-15min to check if the
pressure of piezometer re-
mains in -0.1MPa.
spanner
and maintain this status for
1-2min to check if the pres-
E close
sure of piezometer remains
in -0.1MPa. If the pressure decreases, there may be leakage.
. Remove the piezometer, open the valve core of liquid valve and gas valve
completely with inner hexagon spanner.
. Tighten the screw caps of valves and refrigerant charging vent.
. Reinstall the handle.
1. With leakage detector:
Check if there is leakage with leakage detector.
2. With soap water:
If leakage detector is not available, please use soap water for leakage detection.
Apply soap water at the suspected position and keep the soap water for more
than 3min. If there are air bubbles coming out of this position, there's a leakage.
32
Check after Installation /
e Check according to the following requirement after finishing installation.
д Items to be checked
>
Possible malfunction
Has the unit been installed firmly?
The unit may drop, shake or emit noise.
Have you done the refrigerant leakage
test?
It may cause insufficient cooling
(heating) capacity.
Is heat insulation of pipeline sufficient?
It may cause condensation and water
dripping.
Is water drained well?
It may cause condensation and water
dripping.
Is the voltage of power supply accord-
ing to the voltage marked on the
nameplate?
It may cause malfunction or damaging
the parts.
Is electric wiring and pipeline installed
correctly?
It may cause malfunction or damaging
the parts.
Is the unit grounded securely?
It may cause electric leakage.
Does the power cord follow the speci-
fication?
It may cause malfunction or damaging
the parts.
Is there any obstruction in the air inlet
and outlet?
It may cause insufficient cooling
(heating) capacity.
The dust and sundries caused during
installation are removed?
It may cause malfunction or damaging
the parts.
The gas valve and liquid valve of
\ connection pipe are open completely?
It may cause insufficient cooling
(heating) capacity.
”
Test Operation /
1. Preparation of test operation
e [he client approves the air conditioner.
e Specify the important notes for air conditioner to the client.
2. Method of test operation
e Put through the power, press ON/OFF button on the remote controller to start
operation.
e Press MODE button to select AUTO, COOL, DRY, FAN and HEAT to check
whether the operation is normal or not.
e If the ambient temperature is lower than 16°C (60.8’F), the air conditioner can’t
start cooling.
33
Configuration of Connection Pipe /
1. Standard length of connection pipe
e 5m(16.4ft), 7.5m(24.6ft), 8m(26.24ft).
2.Min. length of connection pipe is 3m(9.84ft).
3.Max. length of connection pipe and max. high difference.
Cooling Max length Max height Cooling Max length Max height
of connec- |. of connec- |.
capacity .. 1 difference capacity — ,. 1 difference
tion pipe tion pipe
5000Btu/h 24000Btu/h
25(82.02ft) 10(32.8f
(1465) 15(49.21ft) 5(16.4ft) (7032W) ( ) 10(32.8t)
(2051W) 15(49.21ft) 5(16.4#) (8204W) 30(98.42ft) ( )
9000Btu/h 36000Btu/h
(2637W) 15(49.21ft) 5(16.4ft) (10548W) 30(98.42ft) 20(65.61ft)
12000Btu/h 42000Btu/h
(3516W) 20(65.61ft) 10(32.8ft) | | (1>306w 30(98.42ft) 20(65.61ft)
18000Btu/h 48000Btu/h
10(32.8ft 2 .61ft
(5274W) 25(82.02ft) 10( ) (14064W) 30(98.42ft) 20(65.61ft)
4. The additional refrigerant oil and refrigerant charging required after prolonging
connection pipe
e After the length of connection pipe is prolonged for 10m(32.8ft) at the basis of
standard length, you should add 5ml of refrigerant oil for each additional 5m
of connection pipe.
e The calculation method of additional refrigerant charging amount (on the basis
of liquid pipe):
Additional refrigerant charging amount = prolonged length of liquid pipe x
additional refrigerant charging amount per meter
e When the length of connection pipe is above 5m(16.4ft, add refrigerant according
to the prolonged length of liquid pipe. The additional refrigerant charging amount
per meter is different according to the diameter of liquid pipe. See the
following sheet.
34
Configuration of Connection Pipe /
Additional refrigerant charging amount for R22, R407C, R410A and R134a
Pipe Expanding Method /
Note:
Improper pipe expanding is the main cause of refrigerant leakage. Please expand
the pipe according to the following steps:
A: Cut the pipe
e Confirm the pipe length according to
the distance of indoor unit and
outdoor unit.
e Cut the required pipe with pipe cutter.
E: Expand the port
e Expand the port with expander.
v X x X
90 canis, uneven burr
al PA
T ] au
Note:
e "A" is different according to the
diameter, please refer to the sheet
below:
B: Remove the burrs
e Remove the burrs with shaper and Max Min Max
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
prevent the burrs from getting into | Ф6-6.35(1/4") 1.3 0.7 0.05 0.02
the pipe. 1 | 0952358) 1.6 1.0 0.06 0.04
1 | Ф12-12.7(1/2") 18 1.0 0.07 0.04
: Ф15.8-16(5/8") 2.4 22 0.09 0.08
|
|
|
|
|
|
|
|
|
|
|
pipe
shaper
downwards
F: Inspection
e Check the quality of expanding port.
If there is any blemish, expand the
port again according to the steps
above.
C: Put on suitable insulating pipe
D: Put on the union nut
e Remove the union nut on the indoor
connection pipe and outdoor valve;
install the union nut on the pipe.
union pipe
smooth surface
improper expanding
YO Yr Yer Y
leaning damaged crack uneven
surface thickness
pipe the length is equal
36
O TATUNG
TATUNG Co. of America, Inc.
2850 El Presidio Street, Long Beach CA 90810, U.S.A
TEL : (310)637-2105 FAX: (310)632-3588
66129918389
">
Download
Advertisement
Key features
Multiple operation modes (Auto, Cool, Dry, Fan, Heat)
Adjustable fan speed control (Auto, Low, Medium, High)
Selectable up & down swing angles for air distribution
TIMER ON/OFF function for programmed operation
X-FAN (Blow) function to reduce moisture in air duct
Temperature display options (set, indoor, outdoor ambient)
TURBO mode for quick cooling or heating
SLEEP function for optimized nighttime comfort
Child lock function for remote controller
Emergency operation via auxiliary button
Frequently asked questions
Check if the remote controller is within the 8m (26.24 ft) signal receiving range and pointing at the receiving window, and if there are obstacles. Ensure batteries are not low or damaged. Avoid interference from fluorescent lamps.
If heating mode is turned on, the unit delays 1-5 minutes to blow air to prevent blowing cold air until the indoor unit reaches a set temperature. If the set temperature is already reached, the indoor unit will stop blowing air.
Check for power failure, loose plug, tripped circuit break, or blown fuse. If the unit stopped recently, wait for 3 minutes before restarting. Also, verify that the remote controller function settings are correct.
Mist can be emitted when indoor temperature and humidity are high and the indoor air is cooled rapidly. This is a normal phenomenon and the mist will disappear after a while as temperature and humidity decrease.
This noise is the sound of refrigerant flowing inside the unit, which is a normal phenomenon, especially when the air conditioner is turned on or off.