Imagine Communications Farad 2300 RAIDar storage system User Guide
広告
広告
User Guide
Nexio® Farad™ 2300 Series
RAIDar Storage Management Utility
May 2014
175-100433-01
Publication Information
© 2014 Imagine Communications Corp. Proprietary and Confidential.
Imagine Communications considers this document and its contents to be proprietary and confidential. Except for making a reasonable number of copies for your own internal use, you may not reproduce this publication, or any part thereof, in any form, by any method, for any purpose, or in any language other than English without the written consent of Imagine Communications. All others uses are illegal.
This publication is designed to assist in the use of the product as it exists on the date of publication of this manual, and may not reflect the product at the current time or an unknown time in the future. This publication does not in any way warrant description accuracy or guarantee the use for the product to which it refers. Imagine
Communications reserves the right, without notice to make such changes in equipment, design, specifications, components, or documentation as progress may warrant to improve the performance of the product.
Trademarks
6800+™, ADC™, CCS Navigator™, Channel ONE™, ChannelView™, ClipSync™, Delay™, D-Series™, D-Series DSX™,
Deliver the Moment™, Delivering the Moment™, FAME™, Farad™, G8™, G-Scribe™, HView™, IconMaster™,
IconLogo™, IconStation™, IconKey™, InfoCaster™, InfoCaster Creator™, InfoCaster Manager™, InfoCaster Player™,
InstantOnline™, Invenio®, Live-Update™, mCAPTURE™, Magellan™, Magellan CCS Navigator™, Magellan Q-SEE™,
MultiService SDN™, NetPlus™, NetVX™, NewsForce™, Nexio® G8™, Nexio AMP® ChannelView™, Nexio® Channel
ONE™, Nexio® ClipSync™, Nexio® Delay™, Nexio® Digital Turnaround Processor™, Nexio® Farad™, Nexio® G-
Scribe™, Nexio® IconKey™, Nexio® IconLogo™, Nexio® IconMaster™, Nexio® IconStation™, Nexio® InfoCaster™,
Nexio® InfoCaster Creator™, Nexio® InfoCaster Manager™, Nexio® InfoCaster Player™, Nexio® InfoCaster Traffic™,
Nexio® InstantOnline™, Nexio® mCAPTURE™, Nexio® NewsForce™, Nexio® NXIQ™, Nexio® Playlist™, Nexio®
Remote™, Nexio®RTX Net™, Nexio® TitleMotion™, Nexio® TitleOne™, Nexio® Velocity ESX™, Nexio® Velocity
PRX™, Nexio® Velocity XNG™, Nexio® Volt™, OPTO+™, Panacea™, Platinum™, Playlist™, Predator II-GRF™, Predator
II-GX™, Punctuate™, Remote™, RTX Net™, QuiC™, Q-SEE™, SD-STAR™, Selenio™, Selenio 6800+™, SelenioNext™,
Selenio X50™, Selenio X85™, Selenio X100™, TitleMotion™, TitleOne™, Velocity ESX™, Velocity PRX™, Velocity
XNG™, Versio™, Videotek® SD-STAR™, X50™, and X85™ are trademarks of Imagine Communications or its subsidiaries.
Altitude Express®, Connectus®, Enabling PersonalizedTV®, ICE® Broadcast System, ICE Illustrate®, ICE-Q® algorithms, ICEPAC®, Imagine ICE®, Inscriber®, Inscriber® Connectus®, Invenio®, NEO®, Nexio®, Nexio AMP®,
PersonalizedTV®, RouterWorks®, Videotek®, Videotek® ASI-STAR®, Videotek® GEN-STAR®, and Videotek® HD-
STAR® are registered trademarks of Imagine Communications or its subsidiaries.
Microsoft® and Windows® are registered trademarks of Microsoft Corporation. HD-BNC is a trademark of
Amphenol Corporation. Some products are manufactured under license from Dolby Laboratories. Dolby and the double-D symbol are registered trademarks of Dolby Laboratories. DTS Neural audio products are manufactured under license from DTS Licensing Limited. DTS and the Symbol are registered trademarks & the DTS Logos are trademarks of DTS, Inc. © 2008-2010 DTS, Inc. All other trademarks and trade names are the property of their respective companies.
Contact Information
Imagine Communications has office locations around the world. For locations and contact information see:
http://www.imaginecommunications.com/contact-us.aspx
Support Contact Information
For support contact information see:
Support Contacts: http://www.imaginecommunications.com/services/technical-support.aspx
eCustomer Portal: http://support.imaginecommunications.com
© 2014 Imagine Communications Corp. Proprietary and Confidential
Contents
NEXIO Farad 2300 Series WBI User Guide 3
4 Contents
NEXIO Farad 2300 Series WBI User Guide 5
6 Contents
Tables
NEXIO Farad 2300 Series WBI User Guide 7
8 Tables
About this guide
This guide provides information about managing an AssuredSAN™ 4000 Series storage system by using its web interface, RAIDar Storage Management Utility.
Intended audience
This guide is intended for storage system administrators.
Prerequisites
Prerequisites for using this product include knowledge of:
• Network administration
• Storage system configuration
• SAN management and DAS
• FC, SAS, and Ethernet protocols
Related documentation
Table 1 Related Documentation
For information about See
Enhancements, known issues, and late-breaking information not included in product documentation
Overview of product shipkit contents and setup tasks
Release Notes
Regulatory compliance and safety and disposal information
NEXIO Farad 2300 Quick Start Guide
AssurredSAN_PRCS_83-00005172-10-01.PDF *
Using a rackmount bracket kit to install an enclosure into a rack
DH_RBKI_83-00004524-13-01-B.PDF
Product hardware setup and related troubleshooting
Using the CLI to configure and manage the product
Event codes and recommended actions
Identifying and installing or replacing FRUs
NEXIO Farad 2300 Series Setup Guide
NEXIO Farad 2300 Series CLI Guide
NEXIO Farad 2300 Series Service Guide
NEXIO Farad 2300 Series Service Guide
For additional information, see the Farad Infrastructure Commissioning Checklist for details on setup and configuration.
NEXIO Farad 2300 Series WBI User Guide 9
Document conventions and symbols
Table 2 Document conventions
Convention Element
Blue text Cross-reference
Blue, underlined text addresses
Bold font
• Key names
• Text typed into a GUI element, such as into a box
• GUI elements that are clicked or selected, such as menu and list items, buttons, and check boxes
Italics font
Monospace font
Text emphasis
• File and directory names
• System output
• Code
• Text typed at the command-line
Monospace, italic font
Monospace, bold font
• Code variables
• Command-line variables
Emphasis of file and directory names, system output, code, and text typed at the command line
CAUTION: Indicates that failure to follow directions could result in damage to equipment or data.
IMPORTANT: Provides clarifying information or specific instructions.
NOTE: Provides additional information.
TIP: Provides helpful hints and shortcuts.
10 About this guide
1 Getting started
RAIDar is a web-based application for configuring, monitoring, and managing the storage system.
Each controller module in the storage system contains a web server, which is accessed when you sign in to
RAIDar. In a dual-controller system, you can access all functions from either controller. If one controller becomes unavailable, you can continue to manage the storage system from the partner controller.
RAIDar is also referred to as the WBI.
Although the RAIDar interface will only display the health of a single Farad stack, you can use Farad Storage
Manager to view health of and access to multiple Farad Gen 1 and Gen 2 stacks from a single display. See the
Farad Storage Manager User Guide for more information.
NOTE: Open WBI sessions can negatively impact system performance.
Configuring and provisioning a new storage system
See the Farad Infrastructure Commissioning Checklist for the latest information on how to setup and configure a system for the first time.
You can make additional configuration and provisioning changes and view system status, as described in later chapters of this guide.
Browser setup
• Use Mozilla Firefox 3 or later, or Microsoft Internet Explorer 8 or later.
• To see the help window, you must enable pop-up windows.
• To optimize the display, use a color monitor and set its color quality to the highest setting.
• To navigate beyond the Sign In page (with a valid user account):
• Set the browser’s local-intranet security option to medium or medium-low. For Internet Explorer 8, adding each controller’s network IP address as a trusted site can avoid access issues.
• Verify that the browser is set to allow cookies at least for the IP addresses of the storage-system network ports.
Signing in
To sign in:
1. In the web browser’s address field, type the IP address of a controller network port and press Enter. The
RAIDar Sign In page is displayed. If the Sign In page does not display, verify that you have entered the correct
IP address.
2. On the Sign In page, enter the name and password of a configured user. The default user name and password are manage and !manage. To display the interface in a language other than the user setting, select the language from the Language list.
Language preferences can be configured for the system and for individual users.
3. Click Sign In. If the system is available, the System Overview page is displayed; otherwise, a message indicates that the system is unavailable.
Tips for signing in and signing out
• Do not include a leading zero in an IP address. For example, enter 10.1.4.6 not 10.1.4.06.
• Multiple users can be signed in to each controller simultaneously.
• For each active RAIDar session an identifier is stored in the browser. Depending on how your browser treats this session identifier, you might be able to run multiple independent sessions simultaneously. Internet
NEXIO Farad 2300 Series WBI User Guide 11
Explorer can run separate RAIDar sessions if you select New Session in the File menu. If you do not select this then all instances of Internet Explorer share the same session, as does Firefox.
• End a RAIDar session by clicking the Sign Out link near the top of the RAIDar window. Do not simply close the browser window.
Tips for using the main window
• The Configuration View panel displays logical and physical components of the storage system. To perform a task, select the component to act on and then either:
• Right-click to display a context menu and select the task to perform. This is the method that help topics describe.
• Click a task category in the main panel and select the task to perform.
• The System Status panel displays System Time and System Events. System Events shows how many events of each severity have occurred in the system. To view event details, click a severity icon. For more information
see Viewing the system event log on page 73.
• Many tables can be sorted by a specific column. To do so, click the column heading to sort low to high; click again to sort high to low. In tables that allow a task to be performed on multiple items, you can select up to 100 items or clear all selections by toggling the checkbox in the table’s heading row.
• Do not use the browser’s Back, Forward, Reload, or Refresh buttons. RAIDar has a single page whose content changes as you perform tasks and automatically updates to show current data.
• A red asterisk ( * ) identifies a required setting.
• The icon in the upper right corner of the main window shows the status of communication between RAIDar, the MC, and the SC, as described in the following table.
Table 3 RAIDar communication status icons
Icon Meaning
RAIDar can communicate with the MC, which can communicate with the SC.
RAIDar cannot communicate with the MC.
RAIDar can communicate with the MC, which cannot communicate with the SC.
• Below the communication status icon, a timer shows how long the session can be idle until you are automatically signed out. This timer resets after each action you perform. One minute before automatic sign-out you are prompted to continue using RAIDar.
• If a RAIDar session is active on a controller and the controller is power cycled or is forced offline by the partner controller or certain other events occur, the session might hang. RAIDar might say that it is
“Connecting” but stop responding, or the page may become blank with the browser status “Done.” After the controller comes back online, the session will not restart. To continue using RAIDar, close and reopen the browser and start a new RAIDar session.
•
•
Tips for using the help window
• To display help for a component in the Configuration View panel, right-click the component and select Help.
To display help for the content in the main panel, click either Help in the menu bar or the help icon in the upper right corner of the panel.
• In the help window, click the table of contents icon to show or hide the Contents pane.
12 Getting started
• As the context in the main panel is changed, the corresponding help topic is displayed in the help window. To prevent this automatic context-switching, click the pin icon . When a help window is pinned ( ), you can still browse to other topics within the help window and you can open a new help window. You cannot unpin a help window; you can only close it.
• If you have viewed more than one help topic, you can click the arrow icons to display the previous or next topic.
System concepts
About user accounts
The system provides three default user accounts and allows a maximum of 12 user accounts to be configured. Any account can be modified or removed except you cannot remove the user you are signed in as.
The default user accounts are for general users that can access the WBI (RAIDar), CLI, FTP, or SMI-S interfaces.
You can also create SNMPv3 user accounts that can access the MIB or receive trap notifications. SNMPv3 user accounts support SNMPv3 security features such as authentication and encryption. For information about configuring trap notifications, see
Configuring SNMP notification on page 32. For information about the MIB, see
General user accounts have these options:
• User Name.
• Password.
• User Roles. Select Monitor or Manage. You cannot change the roles of user manage.
• Monitor. The user has access to the WBI and CLI. A user with role Monitor may view system settings but cannot change them.
• Manage. The user has access to the WBI, CLI, FTP interface, and SMI-S interface. A user with role
Manage may view and change system settings.
• User Type. Identifies the user’s experience level: Standard, Advanced, or Diagnostic.
• WBI Access. Allows access to the web-based management interface.
• CLI Access. Allows access to the command-line management interface.
• FTP Access. Allows access to the FTP interface, which can be used instead of the WBI to install firmware updates and download logs.
• SMI-S Access. Allows access to the SMI-S interface, used for remote management of the system through your network.
• Base Preference. The base for entry and display of storage-space sizes. In base 2, sizes are shown as powers of
2, using 1024 as a divisor for each magnitude. In base 10, sizes are shown as powers of 10, using 1000 as a divisor for each magnitude. Operating systems usually show volume size in base 2. Disk drives usually show size in base 10. Memory (RAM and ROM) size is always shown in base 2.
• Precision Preference. The number of decimal places (1–10) for display of storage-space sizes.
• Unit Preference. The unit for display of storage-space sizes: Auto, TB, GB, or MB.
The Auto option lets the system determine the proper unit for a size. Based on the precision setting, if the selected unit is too large to meaningfully display a size, the system uses a smaller unit for that size. For example, if the unit is set to TB, precision is set to 1, and base is set to 10, the size 0.11709 TB is shown as
117.1 GB.
• Temperature Preference. The scale for display of temperature values: Celsius or Fahrenheit.
• Auto Sign Out. The amount of time that the user’s session can be idle before the user is automatically signed out (2–720 minutes). Note: It is recommended that this value remain at the default setting of 30 minutes.
• Locale. The user’s preferred display language, which overrides the system’s default display language.
Installed language sets include Chinese-Simplified, Chinese-Traditional, Dutch, English, French, German,
Italian, Japanese, Korean, and Spanish.
SNMPv3 user accounts have these options:
• User Name.
• Password.
NEXIO Farad 2300 Series WBI User Guide 13
• SNMP user type. Either: User Access, which allows the user to view the SNMP MIB; or Trap Target, which allows the user to receive SNMP trap notifications. Trap Target uses the IP address set with the Trap Host
Address option.
• Authentication Type. Either: MD5 authentication; SHA authentication; or none (no authentication).
Authentication uses the password set with the Password option.
• Privacy Type. Either: DES; AES; or none (no encryption). Encryption uses the password set with the Privacy
Password option.
• Privacy Password. The encryption password.
• Trap Host Address. The IP address of the host system that will receive SNMP traps.
Table 4 Settings for default users
Locale Name monitor !monitor
manage !manage
ftp
Password
!ftp
Roles Type Interfaces enabled
Monitor Standard WBI, CLI 10
Monitor,
Manage
WBI, CLI,
FTP,
SMI-S
Monitor,
Manage
FTP
Base Prec.
Units Temp.
Auto
Sign
Out
1 Auto Celsius 30
Min.
English
NOTE: To secure the storage system, set a new password for each default user.
Related topics
•
Configuring user accounts on page 33
About vdisks
A vdisk is a virtual disk that is composed of one or more disks, and has the combined capacity of those disks. The number of disks that a vdisk can contain is determined by its RAID level. All disks in a vdisk must be the same type (SAS SSD, enterprise SAS, or midline SAS). A maximum of 64 vdisks per controller and 128 per system can exist. A vdisk is equilavent to an array in Farad Gen 1 and would have a name in the format of Grp 001, Grp 002, etc.
See the Farad Infrastructure Commissioning Checklist for details on creating the naming vdisks.
A vdisk can contain different models of disks, and disks with different capacities. For example, a vdisk can include a 500 GB disk and a 750 GB disk. If you mix disks with different capacities, the smallest disk determines the logical capacity of all other disks in the vdisk, regardless of RAID level. For example, if a RAID0 vdisk contains one 500 GB disk and four 750 GB disks, the capacity of the vdisk is equivalent to approximately five 500
GB disks.
Each disk has metadata that identifies whether the disk is a member of a vdisk, and identifies other members of that vdisk. This enables disks to be moved to different slots in a system; an entire vdisk to be moved to a different system; and a vdisk to be quarantined if disks are detected missing.
When a vdisk is created the system automatically assigns the owner to balance the number of vdisks each controller owns.
In a dual-controller system, when a controller fails, the partner controller assumes temporary ownership of the failed controller’s vdisks and resources. If a fault-tolerant cabling configuration is used to connect the controllers to drive enclosures and hosts, both controllers’ LUNs are accessible through the partner.
When you create a vdisk you should specify a chunk size and other settings as described in the Farad
Infrastructure Commissioning Checklist. The following information is provided for the reader’s information only.
The chunk size is the amount of contiguous data that is written to a disk before moving to the next disk. After a vdisk is created its chunk size cannot be changed. For example, if the host is writing data in 16 KB transfers, that
14 Getting started
size would be a good choice for random transfers because one host read would generate the read of exactly one disk in the volume. That means if the requests are random-like, then the requests would be spread evenly over all of the disks, which is good for performance. If you have 16 KB accesses from the host and a 64 KB block size, then some of the hosts accesses would hit the same disk; each chunk contains four possible 16 KB groups of data that the host might want to read, which is not an optimal solution. Alternatively, if the host accesses were 128 KB, then each host read would have to access two disks in the vdisk. For random patterns, that ties up twice as many disks.
When you create a vdisk you can also create volumes within it. A volume is a logical subdivision of a vdisk, and can be mapped to controller host ports for access by hosts. The storage system presents only volumes, not vdisks, to hosts. A “volume” is the equivalent to a “disk” in Farad Gen 1 and would have a name in the format of Disk
001, Disk 002, etc.
See the Farad Infrastructure Commissioning Checklist for details on creating and naming volumes.
Related topics
•
•
•
• Vdisk topics in
Provisioning the system on page 47
•
Configuring an existing vdisk on page 44
•
Verifying a vdisk (Not supported in Farad Gen 2) on page 66
•
Scrubbing a vdisk (Not supported in Farad Gen 2) on page 67
•
Viewing information about a vdisk ( page 75
), all vdisks (
•
Removing a vdisk from quarantine on page 67
About spares
A controller automatically reconstructs or rebuilds a fault-tolerant vdisk (RAID 6) when one or more of its disks fails and a compatible spare disk is available. A compatible disk has enough capacity to replace the failed disk and is the same type (SAS SSD, enterprise SAS, or midline SAS).
There are three types of spares:
• Dedicated spare. Reserved for use by a specific vdisk to replace a failed disk. Most secure way to provide spares for vdisks but expensive to reserve a spare for each vdisk. Dedicated spare is not supported in Farad
Gen 2.
• Global spare. Reserved for use by any fault-tolerant vdisk to replace a failed disk.
• Dynamic spare. An available compatible disk that is automatically assigned to replace a failed disk in a fault-tolerant vdisk. Dynamic spare is not supported in Farad Gen 2.
When a disk fails, the system looks for a dedicated spare first. If it does not find a dedicated spare, it looks for a global spare. If it does not find a compatible global spare and the dynamic spares option is enabled, it takes any available compatible disk. If no compatible disk is available, reconstruction cannot start.
TIP: For more information in setting up Global Spares, see the Farad Infrastructure Commissioning Checklist.
Related topics
•
Configuring dynamic spares (Not supported in Farad Gen 2) on page 39
•
Managing dedicated spares (Not supported in Farad Gen 2) on page 44
•
Managing global spares on page 51
•
Using the Provisioning Wizard on page 47
•
•
Viewing information about a vdisk ( page 75
) or all vdisks (
NEXIO Farad 2300 Series WBI User Guide 15
About volumes
A volume is a logical subdivision of a vdisk, and can be mapped to controller host ports for access by hosts. A mapped volume provides the storage for a file system partition you create with your operating system or third-party tools. The storage system presents only volumes, not vdisks, to hosts. A vdisk can have a maximum of
128 volumes. For Farad Gen 2, each vdisk has only one associated volume.
You can create a vdisk that has one volume or multiple volumes. Multiple volumes in a single vdisk are not supported in Farad Gen 2. See the Farad Infrastructure Commissioning Checklist for more information on setting up volumes.
• Single-volume vdisks work well in environments that need one large, fault-tolerant storage space for data on one host. A large database accessed by users on a single host that is used only for that application is an example.
• Multiple-volume vdisks (not supported in Farad Gen 2) work well when you have very large disks and you want to make the most efficient use of disk space for fault tolerance (parity and spares). For example, you could create one 10 TB RAID5 vdisk and dedicate one spare to the vdisk. This minimizes the amount of disk space allocated to parity and spares compared to the space required if you created five 2 TB RAID5 vdisks.
However, I/O to multiple volumes in the same vdisk can slow system performance.
When you create volumes you can specify their sizes. If the total size of a vdisk’s volumes equals the size of the vdisk, you will not have any free space. Without free space, you cannot add or expand volumes. If you need to add or expand a volume in a vdisk without free space, you can delete a volume to create free space. Or, you can expand the vdisk and then either add a volume or expand a volume to use the new free space.
You can use a volume’s default name or change it to identify the volume’s purpose. For example, a volume used to store payroll information can be named Payroll.
You can create vdisks with volumes by using the Provisioning Wizard, or you can create volumes manually.
Related topics
•
•
About volume mapping on page 17
•
About volume cache options on page 17
• Volume topics in
Provisioning the system on page 47
•
Changing a volume’s name on page 45
•
Changing a volume’s cache settings on page 45
•
Viewing information about a volume on page 78
About hosts
A host identifies an external port that the storage system is attached to. The external port may be a port in an I/O adapter, such as an FC HBA, in a server, or a port in a network switch.
The controllers automatically discover hosts that have sent an inquiry
command or a report luns
command to the storage system. Hosts typically do this when they boot up or rescan for devices. When the command from the host occurs, the system saves the host ID. The ID for an FC or SAS host is its WWPN. You can also manually create entries for hosts.
You can assign a name to a host to make it easy to recognize for volume mapping. A maximum of 64 names can be assigned.
The Configuration View panel lists hosts by name, or if they are unnamed, by ID.
Related topics
•
Using the Configuration Wizard on page 27
•
Changing host interface settings on page 37
•
•
•
Changing a host’s name on page 56
16 Getting started
•
Changing host mappings on page 56
• Viewing information about a host (
page 80 ) or all hosts ( page 80
)
About volume mapping
Each volume has default host-access settings that are set when the volume is created; these settings are called the
default mapping. The default mapping applies to any host that has not been explicitly mapped using different settings. Explicit mappings for a volume override its default mapping. Explicit mappings are not supported in
Farad Gen 2.
Default mapping enables all attached hosts to see a volume using a specified LUN and access permissions set by the administrator. This means that when the volume is first created, all connected hosts can immediately access the volume using the advertised default mapping settings. This behavior is expected by some operating systems, such as Microsoft Windows, which can immediately discover the volume. The advantage of a default mapping is that all connected hosts can discover the volume with no additional work by the administrator. The disadvantage is that all connected hosts can discover the volume with no restrictions. Therefore, this process is not recommended for specialized volumes that require restricted access.
You can change a volume’s default mapping, and create, modify, or delete explicit mappings. A mapping can specify read-write, read-only, or no access through one or more controller host ports to a volume. When a mapping specifies no access, the volume is masked. You can apply access privileges to one or more of the host ports on either controller. To maximize performance, map a volume to at least one host port on the controller that owns it.
To sustain I/O in the event of controller failure, map to at least one host port on each controller.
For example, a payroll volume could be mapped with read-write access for the Human Resources host and be masked for all other hosts. An engineering volume could be mapped with read-write access for the Engineering host and read-only access for other departments’ hosts.
A LUN identifies a mapped volume to a host. Both controllers share a set of LUNs, and any unused LUN can be assigned to a mapping; however, each LUN can only be used once per volume as its default LUN. For example, if
LUN 5 is the default for Volume1, no other volume in the storage system can use LUN 5 as its default LUN. For explicit mappings, the rules differ: LUNs used in default mappings can be reused in explicit mappings for other volumes and other hosts.
TIP: When an explicit mapping is deleted, the volume’s default mapping takes effect. Therefore, it is recommended to use the same LUN for explicit mappings as for the default mapping.
Volume mapping settings are stored in disk metadata. If enough of the disks used by a volume are moved into a different enclosure, the volume’s vdisk can be reconstructed and the mapping data is preserved.
The 4000 Series storage-system models use ULP, which can expose all LUNs through all host ports on both controllers. The interconnect information is managed in the controller firmware. ULP appears to the host as an active-active storage system where the host can choose any available path to access a LUN regardless of vdisk ownership. When ULP is in use, the controllers’ operating/redundancy mode is shown as Active-Active ULP.
ULP uses the T10 Technical Committee of INCITS ALUA extensions, in SPC-3, to negotiate paths with aware host systems. Unaware host systems see all paths as being equal.
Related topics
•
Using the Provisioning Wizard on page 47
•
Changing a volume’s default mapping ( page 53
) or explicit mappings (
)
•
Changing host mappings on page 56
• Viewing information about a volume (
page 80 ), or all hosts ( page 80
)
About volume cache options
You can set options that optimize reads and writes performed for each volume. See the Farad Infrastructure
Commissioning Checklist for more information on setting cache options.
NEXIO Farad 2300 Series WBI User Guide 17
Using write-back or write-through caching
CAUTION: Only disable write-back caching if you fully understand how the host operating system, application, and adapter move data. If used incorrectly, you might hinder system performance.
You can change a volume’s write-back cache setting. Write-back is a cache-writing strategy in which the controller receives the data to be written to disks, stores it in the memory buffer, and immediately sends the host operating system a signal that the write operation is complete, without waiting until the data is actually written to the disk.
Write-back cache mirrors all of the data from one controller module cache to the other. Write-back cache improves the performance of write operations and the throughput of the controller.
When write-back cache is disabled, write-through becomes the cache-writing strategy. Using write-through cache, the controller writes the data to the disks before signaling the host operating system that the process is complete.
Write-through cache has lower write operation and throughput performance than write-back, but it is the safer strategy, with minimum risk of data loss on power failure. However, write-through cache does not mirror the write data because the data is written to the disk before posting command completion and mirroring is not required. You can set conditions that cause the controller to change from write-back caching to write-through caching.
In both caching strategies, active-active failover of the controllers is enabled.
You can enable and disable the write-back cache for each volume. By default, volume write-back cache is enabled.
Because controller cache is backed by super-capacitor technology, if the system loses power, data is not lost. For most applications, this is the correct setting.
If you are doing random access to this volume, leave the write-back cache enabled.
TIP: The best practice for a fault-tolerant configuration is to use write-back caching.
Optimizing read-ahead caching (Not supported in Farad Gen 2)
CAUTION: Only change read-ahead cache settings if you fully understand how the host operating system, application, and adapter move data so that you can adjust the settings accordingly.
You can optimize a volume for sequential reads or streaming data by changing its read-ahead cache settings. Read ahead is triggered by two back-to-back accesses to consecutive LBA ranges, whether forward (increasing LBAs) or reverse (decreasing LBAs).
You can change the amount of data read in advance after two back-to-back reads are made. Increasing the read-ahead cache size can greatly improve performance for multiple sequential read streams; however, increasing read-ahead size will likely decrease random read performance.
• The Default option works well for most applications: it sets one chunk for the first access in a sequential read and one stripe for all subsequent accesses. The size of the chunk is based on the chunk size used when you created the vdisk (the default is 64 KB). Non-RAID and RAID1 vdisks are considered to have a stripe size of
64 KB.
• Specific size options let you select an amount of data for all accesses.
• The Maximum option lets the controller dynamically calculate the maximum read-ahead cache size for the volume. For example, if a single volume exists, this setting enables the controller to use nearly half the memory for read-ahead cache.
Only use Maximum when disk latencies must be absorbed by cache. For example, for read-intensive applications, you will want data that is most often read to be in cache so that the response to the read request is very fast; otherwise, the controller has to locate which disks the data is on, move it up to cache, and then send it to the host. Do not use Maximum if more than two volumes are owned by the controller on which the read-ahead setting is being made. If there are more than two volumes, there is contention on the cache as to which volume’s read data should be held and which has the priority; each volume constantly overwrites the other volume’s data in cache, which could result in taking a lot of the controller’s processing power.
18 Getting started
• The Disabled option turns off read-ahead cache. This is useful if the host is triggering read ahead for what are random accesses. This can happen if the host breaks up the random I/O into two smaller reads, triggering read ahead.
You can also change the optimization mode.
• The Standard read-ahead caching mode works well for typical applications where accesses are a combination of sequential and random; this method is the default. For example, use this mode for transaction-based and database update applications that write small files in random order.
• You can use No-mirror mode. When this mode is enabled, each controller stops mirroring its cache metadata to the partner controller. This improves write I/O response time but at the risk of losing data during a failover.
ULP behavior is not affected, with the exception that during failover any write data in cache will be lost.
Related topics
•
Changing a volume’s cache settings on page 45
•
Changing system cache settings on page 40
•
Viewing information about a volume on page 78
About RAID levels
Farad Gen 2 uses RAID 6 only. The following information is provided for the reader’s information only. The
RAID controllers enable you to set up and manage vdisks, whose storage may be spread across multiple disks.
This is accomplished through firmware resident in the RAID controller. RAID refers to vdisks in which part of the storage capacity may be used to achieve fault tolerance by storing redundant data. The redundant data enables the system to reconstruct data if a disk in the vdisk fails.
Hosts see each partition of a vdisk, known as a volume, as a single disk. A volume is actually a portion of the storage space on disks behind a RAID controller. The RAID controller firmware makes each volume appear as one very large disk. Depending on the RAID level used for a vdisk, the disk presented to hosts has advantages in fault-tolerance, cost, performance, or a combination of these.
NOTE: Choosing the right RAID level for your application improves performance.
The following tables:
• Provide examples of appropriate RAID levels for different applications
• Compare the features of different RAID levels
• Describe the expansion capability for different RAID levels
Table 5 Example applications and RAID levels
Application
Testing multiple operating systems or software development (where redundancy is not an issue)
Fast temporary storage or scratch disks for graphics, page layout, and image rendering
Workgroup servers
Video editing and production
Network operating system, databases, high availability applications, workgroup servers
Very large databases, web server, video on demand
Mission-critical environments that demand high availability and use large sequential workloads
RAID level
5
50
6
NRAID
0
1 or 10
3
NEXIO Farad 2300 Series WBI User Guide 19
Table 6 RAID level comparison
RAID level
Min. disks
Description
NRAI
D
0
1
3
5
6
10
(1+0)
50
(5+0)
1
2
2
3
3
4
4
6
Non-RAID, nonstriped mapping to a single disk
Data striping without redundancy
Disk mirroring
Block-level data striping with dedicated parity disk
Block-level data striping with distributed parity
Block-level data striping with double distributed parity
Stripes data across multiple RAID1 sub-vdisks
Stripes data across multiple RAID5 sub-vdisks
Strengths Weaknesses
Ability to use a single disk to store additional data
Highest performance
Not protected, lower performance
(not striped)
No data protection: if one disk fails all data is lost
Very high performance and data protection; minimal penalty on write performance; protects against single disk failure
High redundancy cost overhead: because all data is duplicated, twice the storage capacity is required
Excellent performance for large, sequential data requests (fast read); protects against single disk failure
Not well-suited for transaction-oriented network applications: single parity disk does not support multiple, concurrent write requests
Best cost/performance for transaction-oriented networks; very high performance and data protection; supports multiple simultaneous reads and writes; can also be optimized for large, sequential requests; protects against single disk failure
Write performance is slower than
RAID0 or RAID1
Best suited for large sequential workloads; non-sequential read and sequential read/write performance is comparable to RAID5; protects against dual disk failure
Higher redundancy cost than RAID5 because the parity overhead is twice that of RAID5; not well-suited for transaction-oriented network applications; non-sequential write performance is slower than RAID5
Highest performance and data protection (protects against multiple disk failures)
High redundancy cost overhead: because all data is duplicated, twice the storage capacity is required; requires minimum of four disks
Better random read and write performance and data protection than RAID5; supports more disks than RAID5; protects against multiple disk failures
Lower storage capacity than RAID5
Table 7 Vdisk expansion by RAID level (Not supported in Farad Gen 2)
Expansion capability RAID level
NRAID
0, 3, 5, 6
1
10
50
Cannot expand.
You can add 1–4 disks at a time.
Cannot expand.
You can add 2 or 4 disks at a time.
You can add one sub-vdisk at a time. The added sub-vdisk must contain the same number of disks as each of the existing sub-vdisks.
Maximum disks
1
16
2
16
32
20 Getting started
About size representations
Parameters such as names of users and volumes have a maximum length in bytes. ASCII characters are 1 byte; most Latin (Western European) characters with diacritics are 2 bytes; most Asian characters are 3 bytes.
Operating systems usually show volume size in base 2. Disk drives usually show size in base 10. Memory (RAM and ROM) size is always shown in base 2. In RAIDar, the base for entry and display of storage-space sizes can be set per user or per session. When entering storage-space sizes only, either base-2 or base-10 units can be specified.
Table 8 Size representations in base 2 and base 10
Base 2
Unit
KiB (kibibyte) 1,024
MiB (mebibyte)
1,024
2
GiB (gibibyte)
1,024
3
TiB (tebibyte)
1,024
4
PiB (pebibyte)
1,024
5
EiB (exbibyte)
1,024
6
Size in bytes
Base 10
Unit Size in bytes
KB (kilobyte) 1,000
MB (megabyte)
1,000
2
GB (gigabyte)
1,000
3
TB (terabyte)
PB (petabyte)
EB (exabyte)
1,000
4
1,000
5
1,000
6
The locale setting determines the character used for the decimal (radix) point, as shown below.
Table 9 Decimal (radix) point character by locale
Language
English, Chinese, Japanese, Korean
Dutch, French, German, Italian, Spanish
Character Examples
Period (.) 146.81 GB
3.0 Gbit/s
Comma (,) 146,81 GB
3,0 Gbit/s
Related topics
•
About user accounts on page 13
About the system date and time
You can change the storage system’s date and time, which are displayed in the System Status panel. It is important to set the date and time so that entries in system logs and event-notification email messages have correct time stamps.
You can set the date and time manually or configure the system to use NTP to obtain them from a network-attached server. When NTP is enabled, and if an NTP server is available, the system time and date can be obtained from the NTP server. This allows multiple storage devices, hosts, log files, and so forth to be synchronized. If NTP is enabled but no NTP server is present, the date and time are maintained as if NTP was not enabled.
NTP server time is provided in UTC, which provides several options:
• If you want to synchronize the times and logs between storage devices installed in multiple time zones, set all the storage devices to use UTC.
• If you want to use the local time for a storage device, set its time zone offset.
• If a time server can provide local time rather than UTC, configure the storage devices to use that time server, with no further time adjustment.
Whether NTP is enabled or disabled, the storage system does not automatically make time adjustments, such as for U.S. daylight savings time. You must make such adjustments manually.
NEXIO Farad 2300 Series WBI User Guide 21
Related topics
•
Changing the system date and time on page 36
About storage-space color codes
RAIDar panels use the following color codes to identify how storage space is used.
Table 10 Storage-space color codes
Area
Overview panels
Vdisk panels
Color Meaning
Total space
Available/free space
Used space
Reserved/overhead space, used for parity, for example
Space used by spares
Wasted space, due to use of mixed disk sizes
About Configuration View icons
The Configuration View panel uses the following icons to let you view physical and logical components of the storage system.
Table 11 Configuration View icons
Icon Meaning
Show all subcomponents
Icon Meaning
Enclosure
Hide all subcomponents
Show the component’s subcomponents
Hide the component’s subcomponents
Storage system
Host/initiator
Vdisk volume
About disk failure and vdisk reconstruction
If one or more disks fail in a fault-tolerant vdisk (RAID 1, 3, 5, 6, 10, or 50) and compatible spares are available, the storage system automatically uses the spares to reconstruct the vdisk. Vdisk reconstruction does not require
I/O to be stopped, so the vdisk can continue to be used while the Reconstruct utility runs.
A compatible spare is one whose capacity is equal to or greater than the smallest disk in the vdisk. A compatible spare has enough capacity to replace the failed disk and is the same type (SAS SSD, enterprise SAS, or midline
SAS). If no compatible spares are available, reconstruction does not start automatically. To start reconstruction manually, replace each failed disk and then do one of the following:
• Add each new disk as a global spare. Remember that a global spare might be taken by a different critical vdisk than the one you intended. When a global spare replaces a disk in a vdisk, the global spare’s icon in the enclosure view changes to match the other disks in that vdisk.
• Enable the Dynamic Spare Capability option to use the new disks without designating them as spares.
RAID6 reconstruction behaves as follows:
• During online initialization, if one disk fails, initialization continues and the resulting vdisk will be degraded
(FTDN status). After initialization completes, the system can use a compatible spare to reconstruct the vdisk.
• During online initialization, if two disks fail, initialization stops (CRIT status). The system can use two compatible spares to reconstruct the vdisk.
• During vdisk operation, if one disk fails and a compatible spare is available, the system begins to use that spare to reconstruct the vdisk. If a second disk fails during reconstruction, reconstruction continues until it is
22 Getting started
complete, regardless of whether a second spare is available. If the spare fails during reconstruction, reconstruction stops.
• During vdisk operation, if two disks fail and only one compatible spare is available, the system waits five minutes for a second spare to become available. After five minutes, the system begins to use that spare to reconstruct one disk in the vdisk (referred to as “fail 2, fix 1” mode). If the spare fails during reconstruction, reconstruction stops.
• During vdisk operation, if two disks fail and two compatible spares are available, the system uses both spares to reconstruct the vdisk. If one of the spares fails during reconstruction, reconstruction proceeds in “fail 2, fix
1” mode. If the second spare fails during reconstruction, reconstruction stops.
When a disk fails, its Fault LED illuminates amber. When a spare is used as a reconstruction target, its Activity
LED blinks green. For details about LED states, see your product’s Setup Guide.
NOTE: Reconstruction can take hours or days to complete, depending on the vdisk RAID level and size, disk speed, utility priority, and other processes running on the storage system. You can stop reconstruction only by deleting the vdisk.
About managed logs (Not supported)
As the storage system operates, it records diagnostic data in several types of log files. The size of any log file is limited, so over time and during periods of high activity, these logs can fill up and begin overwriting their oldest data. The managed logs feature allows log data to be transferred to a log-collection system before any data is lost.
The transfer does not remove any data from the logs in the storage system. The default is disabled.
The log-collection system is a host computer that is designated to receive the log data transferred from the storage system. Because log data is transferred incrementally, the log-collection system is responsible for integrating the log data for display and analysis.
The managed logs feature can be configured to operate in push mode or pull mode:
• In push mode, when log data has accumulated to a significant size, the storage system sends notifications with attached log files via email to the log-collection system. The notification will specify the storage-system name, location, contact, and IP address, and will contain a single log segment in a compressed zip file. The log segment will be uniquely named to indicate the log-file type, the date/time of creation, and the storage system.
This information will also be in the email subject line. The file name format is logtype_yyyy_mm_dd__hh_mm_ss.zip
.
• In pull mode, when log data has accumulated to a significant size, the system sends notifications via email,
SNMP, or SMI-S to the log-collection system, which can then use FTP to transfer the appropriate logs from the storage system. The notification will specify the storage-system name, location, contact, and IP address and the log-file type that needs to be transferred.
The managed logs feature monitors the following controller-specific log files:
• EC log, which includes EC debug data, EC revisions, and PHY statistics
• SC debug log and controller event log
• SC crash logs, which include the SC boot log
• MC log
Each log-file type also contains system-configuration information. The capacity status of each log file is maintained, as well as the status of what data has already been transferred. Three capacity-status levels are defined for each log file:
• Need to transfer: The log file has filled to the threshold at which content needs to be transferred. This threshold varies for different log files. When this level is reached:
• In push mode, informational event 400 and all untransferred data is sent to the log-collection system.
• In pull mode, informational event 400 is sent to the log-collection system, which can then request the untransferred log data. The log-collection system can pull log files individually, by controller.
• Warning: The log file is nearly full of untransferred data. When this level is reached, warning event 401 is sent to the log-collection system.
NEXIO Farad 2300 Series WBI User Guide 23
• Wrapped: The log file has filled with untransferred data and has started to overwrite its oldest data. When this level is reached, informational event 402 is sent to the log-collection system.
Following the transfer of a log’s data in push or pull mode, the log’s capacity status is reset to zero to indicate that there is no untransferred data.
NOTE: In push mode, if one controller is offline its partner will send the logs from both controllers.
Alternative methods for obtaining log data are to use RAIDar’s Save Logs panel or the FTP interface’s get logs
command. These methods will transfer the entire contents of a log file without changing its capacity-status level. Use of Save Logs or get logs is expected as part of providing information for a technical support request. For information about using the Save Logs panel, see
Saving logs on page 62. For information about
using the FTP interface, see the RAIDar User Guide.
Related topics
•
Configuring email notification on page 32 (for push mode)
•
Configuring SNMP notification on page 32 (for pull mode)
•
Changing management interface settings on page 31 (to enable SNMP or SMI-S for pull mode)
•
Enabling/disabling managed logs on page 43
•
Testing notifications on page 65
About performance monitoring
The storage system samples disk-performance statistics every quarter hour and retains performance data for 6 months. You can view these historical performance statistics to identify disks that are experiencing errors or are performing poorly.
RAIDar displays historical performance statistics in graphs for ease of analysis. You can view historical performance statistics either for a single disk or for all disks in a vdisk. By default, the graphs will show the latest
50 data samples, but you can specify the time period to display. If the specified time period includes more than 50 samples, their data will be aggregated into 50 samples; the graphs show a maximum of 50 samples. Data shown will be up-to-date as of the time it is requested for display, and summary statistics will be updated when a new sample is taken.
Disk-performance graphs include:
• Data Transferred
• Data Throughput
• I/O
• IOPS
• Average Response Time
• Average I/O Size
• Disk Error Counters
• Average Queue Depth
Vdisk-performance graphs include:
• Data Transferred (B)
• Data Throughput (B/s)
• Average Response Time (
μs)
You can save historical statistics in CSV format to a file for import into a spreadsheet or other third-party application. You can also reset historical statistics, which clears the retained data and continues to gather new samples.
24 Getting started
NOTE: RAIDar does not show live statistics. For information about viewing live statistics, see the CLI
Reference Guide.
Related topics
•
Vdisk performance on page 77 (to view historical performance statistics for a vdisk)
•
Disk performance on page 83 (to view historical performance statistics for a disk)
•
Resetting historical disk-performance statistics on page 68
•
Saving historical disk-performance statistics on page 69
NEXIO Farad 2300 Series WBI User Guide 25
26 Getting started
2 Configuring the system
Using the Configuration Wizard
The Configuration Wizard is not recommended for Farad Gen 2. See the Farad Infrastructure Commissioning
Checklist for more information on configuring the system.
The Configuration Wizard helps you initially configure the system or change system configuration settings.
The wizard guides you through the following steps. For each step you can view help by clicking the help icon in the wizard panel. As you complete steps they are highlighted at the bottom of the panel. If you cancel the wizard at any point, no changes are made.
• Change passwords for the default users
• Configure each controller’s network port
• Enable or disable system-management services
• Enter information to identify the system
• Configure event notification
• Configure controller host ports
• Confirm changes and apply them
When you complete this wizard you are given the option to start the Provisioning Wizard to provision storage.
Step 1: Starting the wizard
1. In the Configuration View panel, right-click the system and select either Configuration > Configuration
Wizard or Wizards > Configuration Wizard. The wizard panel appears, displaying Step 1 of 8: Introduction.
2. Review the text, then click Next to continue.
Step 2: Changing default passwords
In the wizard panel, Step 2 of 8: Password Setup displays.
The system provides the default users manage
and monitor
. To secure the storage system, set a new password for each default user. A password is case sensitive and can include a maximum of 32 bytes using characters except a backslash, comma, or double quote.
Click Next to continue.
Step 3: Configuring network ports
In the wizard panel, Step 3 of 8: Network Configuration displays.
You can configure addressing parameters for each controller’s network port. You can set static IP values or use
DHCP.
In DHCP mode, network port IP address, subnet mask, and gateway values are obtained from a DHCP server if one is available. If a DHCP server is unavailable, current addressing is unchanged. You must have some means of determining what addresses have been assigned, such as the list of bindings on the DHCP server.
Each controller has the following factory-default IP settings:
• IP address source: manual
• Controller A IP address: 10.0.0.2
• Controller B IP address: 10.0.0.3
• IP subnet mask: 255.255.255.0
• Gateway IP address: 10.0.0.1
NEXIO 2300 Series WBI User Guide 27
When DHCP is enabled by selecting DHCP in the IP address source list, the following initial values are set and remain set until the system is able to contact a DHCP server for new addresses:
• Controller IP addresses: 169.254.x.x (where the value of x.x is the lowest 16 bits of the controller serial number)
• IP subnet mask: 255.255.0.0
• Gateway IP address: 0.0.0.0
169.254.x.x addresses (including gateway 169.254.0.1) are on a private subnet that is reserved for unconfigured systems and the addresses are not routable. This prevents the DHCP server from reassigning the addresses and possibly causing a conflict where two controllers have the same IP address. As soon as possible, change these IP values to proper values for your network.
CAUTION: Changing IP settings can cause management hosts to lose access to the storage system.
To use DHCP to obtain IP values for network ports
1. Set IP address source to DHCP.
2. Click Next to continue.
To set static IP values for network ports
1. Determine the IP address, subnet mask, and gateway values to use for each controller.
2. Set IP address source to manual.
3. Set the values for each controller. You must set a unique IP address for each network port. All fields are required.
4. Click Next to continue.
Step 4: Enabling system-management services
In the wizard panel, Step 4 of 8: Enable System-Management Services displays.
You can enable or disable management-interface services to limit the ways in which users and host-based management applications can access the storage system. Network management interfaces operate out-of-band and do not affect host I/O to the system. The network options are:
• WBI. The primary interface for managing the system. You can enable use of HTTP, or HTTPS for increased security, or both.
• CLI. An advanced user interface for managing the system. You can enable use of Telnet, or SSH for increased security, or both.
• SMI-S. Used for remote management of the system through your network. SMI-S is required for the Farad
Storage Manager. See the Farad Infrastructure Commissioning Checklist for more information on proper setup. You can enable use of secure (encrypted) or unsecure (unencrypted) SMI-S:
• Encrypted. (Required for Farad Storage Manager) Select the box to enable encryption. This option allows
SMI-S clients to communicate with each controller’s embedded SMI-S provider via HTTPS port 5989.
HTTPS port 5989 and HTTP port 5988 cannot be enabled at the same time, so enabling this option will disable port 5988. This is the default.
• Unencrypted. Clear the box to disable encryption. This option allows SMI-S clients to communicate with each controller’s embedded SMI-S provider via HTTP port 5988. HTTP port 5988 and HTTPS port 5989 cannot be enabled at the same time, so enabling this option will disable port 5989.
The SMI-S is a SNIA standard that enables interoperable management for storage networks and storage devices. SMI-S replaces multiple disparate managed object models, protocols, and transports with a single object-oriented model for each type of component in a storage network. The specification was created by
SNIA to standardize storage management solutions. SMI-S enables management applications to support storage devices from multiple vendors quickly and reliably because they are no longer proprietary. SMI-S detects and manages storage elements by type, not by vendor.
28 Configuring the system
• Other Interfaces. Other methods of interaction with the system. You can enable FTP, SNMP, Service Debug,
In-band SES Capability, or all.
• FTP. A secondary interface for installing firmware updates and downloading logs.
• SNMP. Used for remote monitoring of the system through your network.
• Service Debug. Used for technical support only.
In-band management interfaces operate through the data path and can slightly reduce I/O performance. The in-band option is:
• In-band SES Capability. Used for in-band monitoring of system status based on SES data.
If a service is disabled, it continues to run but cannot be accessed. To allow specific users to access WBI, CLI,
FTP or SMI-S, see About user accounts on page 13.
To change management interface settings
1. Enable the options that you want to use to manage the storage system, and disable the others.
2. Click Next to continue.
Step 5: Setting system information
In the wizard panel, Step 5 of 8: System Information displays.
Enter a System Name, System Contact person, System Location, and System Information description. Each value can include a maximum of 79 bytes, using characters except double quote or backslash. The name is shown in the browser title bar or tab. The name, location, and contact are included in event notifications. All four values are recorded in system debug logs for reference by service personnel.
Click Next to continue.
Step 6: Configuring event notification
In the wizard panel, Step 6 of 8: Configure Event Notification displays.
Configure email addresses and SNMP trap hosts to receive event notifications, and configure the managed logs feature.
1. In the Email Configuration section, set the options:
• Notification Level. Select the minimum severity for which the system should send notifications: Critical
(only); Error (and Critical); Warning (and Error and Critical); Informational (all). The default is none, which disables email notification.
• SMTP Server address (required). The IP address of the SMTP mail server to use for the email messages. If the mail server is not on the local network, make sure that the gateway IP address was set in the network configuration step. The default is 0.0.0.0.
• Sender Name. The sender name that is joined with an @ symbol to the domain name to form the “from” address for remote notification. This name provides a way to identify the system that is sending the notification.The sender name can have a maximum of 64 bytes. Because this name is used as part of an email address, do not include spaces. For example: Storage-1. If no sender name is set, a default name is created.
• Sender Domain (required). The domain name that is joined with an @ symbol to the sender name to form the “from” address for remote notification. The domain name can have a maximum of 255 bytes. Because this name is used as part of an email address, do not include spaces. For example: MyDomain.com. If the domain name is not valid, some email servers will not process the mail. The default is mydomain.com.
• Email Address fields. Up to three email addresses that the system should send notifications to. Email addresses must use the format user-name@domain-name. Each email address can have a maximum of 320 bytes. For example: [email protected] or [email protected].
NEXIO 2300 Series WBI User Guide 29
2. In the SNMP Configuration section, set the options:
• Notification Level. Select the minimum severity for which the system should send notifications: Critical
(only); Error (and Critical); Warning (and Error and Critical); Informational (all). The default is none, which disables SNMP notification.
• Read Community. The SNMP read password for your network. This password is also included in traps that are sent. The value is case sensitive; can include letters, numbers, hyphens, and underscores; and can have a maximum of 31 bytes. The default is public
.
• Write Community. The SNMP write password for your network. The value is case sensitive; can include letters, numbers, hyphens, and underscores; and can have a maximum of 31 bytes. The default is private
.
• Trap Host Address fields. IP addresses of up to three host systems that are configured to receive SNMP traps. The default is 0.0.0.0.
3. In the Managed Logs Notifications section, set the options:
• Log Destination. The email address of the log-collection system. The email addresses must use the format
user-name@domain-name
and can have a maximum of 320 bytes. For example:
.
• Include Logs. When the managed logs feature is enabled, this option activates “push” mode, which automatically attaches system log files to managed-logs email notifications that are sent to the log-collection system. The default is enabled.
NOTE: These options configure the managed logs feature but do not enable it, which is done on the
Configuration > Advanced Settings > System Utilities panel.
4. Click Next to continue.
Step 7: Configuring host ports
In the wizard panel, Step 7 of 8: Port Configuration displays.
To enable the system to communicate with hosts or with remote systems, you must configure the system’s host-interface options. There are options for FC ports but not for SAS ports. For SAS ports there are no host-interface options. Each SAS port displays the text, There are no configurable settings for SAS. Click Next to continue.
For FC ports you can set these options:
• Speed. Can be set to auto (the default), which auto-negotiates the proper link speed with the host, or to 2 Gbit
(Gbit/s), 4 Gbit, or 8 Gbit. Because a speed mismatch prevents communication between the port and host, set a speed only if you need to force the port to use a known speed for testing, or you need to specify a mutually supported speed for more than two FC devices connected in an arbitrated loop.
• Connection Mode. Can be set to loop, point-to-point, or auto (the default). Loop protocol can be used in a physical loop or in a direct physical connection between two devices. Point-to-point protocol can only be used on a direct physical connection between exactly two devices. Auto sets the mode based on the detected connection type.
• Loop IDs can be set, per controller, to use soft or hard target addressing:
• Soft target addressing (the default) enables a LIP to determine the loop ID. Use this setting if the loop ID is permitted to change after a LIP or power cycle.
• Hard target addressing requests a specific loop ID that should remain after a LIP or power cycle. If the port cannot acquire the specified ID, it is assigned a soft target address. Use this option if you want ports to have specific addresses, if your system checks addresses in reverse order (lowest address first), or if an application requires that specific IDs be assigned to recognize the controller.
To change FC host-interface settings
1. For controller host ports that are attached to hosts:
• Set the speed to the proper value to communicate with the host.
• Set the connection mode.
30 Configuring the system
2. For each controller, set the loop ID to use soft or hard target addressing. To use soft target addressing, select
(enable) Soft?. To use hard target addressing, clear (disable) Soft? and enter an address in the range 0–125.
You cannot set the same hard target address for both controllers. An asterisk indicates that the value is required.
3. Click Next to continue.
Step 8: Confirming configuration changes
In the wizard panel, Step 8 of 8: Confirm the Configuration Changes displays with a table listing all the values selected in the wizard.
Confirm that the values listed in the wizard panel are correct.
• If they are not correct, click Previous to return to previous steps and make necessary changes.
• If they are correct, click Finish to apply the setting changes and finish the wizard.
NOTE: If you changed a controller’s FC loop ID setting, you must restart the controller to make the change take effect.
Configuring system services
Changing management interface settings
You can enable or disable management interfaces to limit the ways in which users and host-based management applications can access the storage system. Network management interfaces operate out-of-band and do not affect host I/O to the system. The network options are:
• WBI. The primary interface for managing the system. You can enable use of HTTP, of HTTPS for increased security, or both.
• CLI. An advanced user interface for managing the system. You can enable use of Telnet, of SSH for increased security, or both.
• SMI-S. Used for remote management of the system through your network. You can enable use of secure
(encrypted) or unsecure (unencrypted) SMI-S:
• Encrypted. Select the box to enable encryption. This option allows SMI-S clients to communicate with each controller’s embedded SMI-S provider via HTTPS port 5989. HTTPS port 5989 and HTTP port 5988 cannot be enabled at the same time, so enabling this option will disable port 5988. This is the default.
• Unencrypted. Clear the box to disable encryption. This option allows SMI-S clients to communicate with each controller’s embedded SMI-S provider via HTTP port 5988. HTTP port 5988 and HTTPS port 5989 cannot be enabled at the same time, so enabling this option will disable port 5989.
• Other Interfaces. Other methods of interaction with the system. You can enable FTP, SNMP, Service Debug,
In-band SES Capability, or all.
• FTP. A secondary interface for installing firmware updates and downloading logs.
• SNMP. Used for remote monitoring of the system through your network.
• Service Debug. Used for technical support only.
In-band management interfaces operate through the data path and can slightly reduce I/O performance. The in-band option is:
• In-band SES Capability. Used for in-band monitoring of system status based on SES data.
If a service is disabled, it continues to run but cannot be accessed. To allow specific users to access WBI, CLI, or
FTP, see About user accounts on page 13.
To change management interface settings
1. In the Configuration View panel, right-click the system and select Configuration > Services > Management.
2. Enable the options that you want to use to manage the storage system, and disable the others.
3. Click Apply. If you disabled any options, a confirmation dialog appears.
NEXIO 2300 Series WBI User Guide 31
4. Click Yes to continue; otherwise, click No. If you click Yes, a processing dialog appears. When processing is complete a success dialog appears.
5. Click OK.
Configuring email notification
You can configure email-notification settings for events and managed logs. For an overview of the managed logs
feature, see About managed logs (Not supported) on page 23.
To configure email notification for events
1. In the Configuration View panel, right-click the system and select Configuration > Services > Email
Notification.
2. In the main panel, set the options:
• Notification Level. Select the minimum severity for which the system should send notifications: Critical
(only); Error (and Critical); Warning (and Error and Critical); Informational (all). The default is none
(Disabled), which disables email notification.
• SMTP Server address (required). The IP address of the SMTP mail server to use for the email messages. If the mail server is not on the local network, make sure that the gateway IP address is set in System Settings
> Network Interfaces.
• Sender Name. The sender name that is joined with an @ symbol to the domain name to form the “from” address for remote notification. This name provides a way to identify the system that is sending the notification. The sender name can have a maximum of 64 bytes. Because this name is used as part of an email address, do not include spaces. For example: Storage-1. If no sender name is set, a default name is created.
• Sender Domain (required). The domain name that is joined with an @ symbol to the sender name to form the “from” address for remote notification. The domain name can have a maximum of 255 bytes. Because this name is used as part of an email address, do not include spaces. For example: MyDomain.com. If the domain name is not valid, some email servers will not process the mail. The default is mydomain.com.
• Email Address fields. Up to three email addresses that the system should send notifications to. Email addresses must use the format user-name@domain-name. Each email address can have a maximum of 320 bytes. For example: [email protected] or [email protected].
3. Click Apply.
4. Send a test message to the configured destinations as described on page 65
.
To configure email notification for managed logs
1. In the Configuration View panel, right-click the system and select Configuration > Services > Email
Notification.
2. In the main panel, set the options:
• Log Destination. The email address of the log-collection system. The email addresses must use the format
user-name@domain-name
and can have a maximum of 320 bytes. For example:
.
• Include Logs. When the managed logs feature is selected (enabled), this option activates “push” mode, which automatically attaches system log files to managed-logs email notifications that are sent to the log-collection system. The default is enabled.
3. Click Apply.
4. Enable log management as described on page 43
.
5. Send a test message to the configured destination as described on
Configuring SNMP notification
To configure SNMP notification of events
1. In the Configuration View panel, right-click the system and select Configuration > Services > SNMP
Notification.
2. In the main panel, set the options:
32 Configuring the system
• Notification Level. Select the minimum severity for which the system should send notifications: Critical
(only); Error (and Critical); Warning (and Error and Critical); Informational (all). The default is none, which disables SNMP notification.
• Read Community. The SNMP read password for your network. This password is also included in traps that are sent. The value is case sensitive; can include any character except single quote and double quote; and can have a maximum of 31 bytes. The default is public.
• Write Community. The SNMP write password for your network. The value is case sensitive; can include any character except single quote and double quote; and can have a maximum of 31 bytes. The default is private
.
• Trap Host Address fields. IP addresses of up to three host systems that are configured to receive SNMP traps. The default is 0.0.0.0.
3. Click Apply.
4. Optionally, send a test message to the configured destinations as described on
Configuring user accounts
Configuring SysLog Server Notification
To configure SysLog Server notification of events
1. In the Configuration View panel, right-click the system and select Configuration > Services > SNMP
Notification.
2. In the main panel, set the options:
• Notification Level. Select the minimum severity for which the system should send notifications: Critical only; Error and Critical; Warning, Error and Critical; Information (all). The default is None, which disables SysLog Server notifications.
• SysLog Server IP Address. IP address of SysLog Server. The default is 0.0.0.0.
• Sys Log Server Port Number. Port Number of Port on SysLog Server (usually port 514). The default is 0.
3. Click Apply.
Adding users
You can create either a general user that can access the WBI, CLI, FTP or SMI-S interfaces, or an SNMPv3 user that can access the MIB or receive trap notifications. SNMPv3 user accounts support SNMPv3 security features such as authentication and encryption.
To add a general user
1. In the Configuration View panel, right-click the system and select Configuration > Users > Add New User.
2. In the main panel, set the options:
• User Name (required). A user name is case sensitive; cannot already exist in the system; cannot include a comma, double quote, backslash, or space; and can have a maximum of 29 bytes.
NOTE: The user name admin is reserved for internal use.
• Password (required). A password is case sensitive and can include a maximum of 32 bytes using characters except a backslash, comma, or double quote.
• SNMPv3 User Definition. This checkbox is cleared by default, which enables general-user options and disables SNMP-user options.
• User Roles. Select Monitor or Manage. You cannot change the roles of user manage.
• Monitor. The user has access to the WBI and CLI. A user with role Monitor may view system settings but cannot change them.
• Manage. The user has access to the WBI, CLI, FTP interface, and SMI-S interface. A user with role
Manage may view and change system settings.
NEXIO 2300 Series WBI User Guide 33
• User Type. Select an option to identify the user’s experience level: Standard, Advanced, or Diagnostic.
• WBI Access. Allows access to the web-based management interface.
• CLI Access. Allows access to the command-line management interface.
• FTP Access. Allows access to the FTP interface, which can be used instead of the WBI to install firmware updates and download logs.
• SMI-S Access. Allows access to the SMI-S interface, used for remote management of the system through your network.
• Base Preference. Select the base for entry and display of storage-space sizes. In base 2, sizes are shown as powers of 2, using 1024 as a divisor for each magnitude. In base 10, sizes are shown as powers of 10, using
1000 as a divisor for each magnitude. Operating systems usually show volume size in base 2. Disk drives usually show size in base 10. Memory (RAM and ROM) size is always shown in base 2.
• Precision Preference. Select the number of decimal places (1–10) for display of storage-space sizes.
• Unit Preference. The unit for display of storage-space sizes: Auto, TB, GB, or MB.
The Auto option lets the system determine the proper unit for a size. Based on the precision setting, if the selected unit is too large to meaningfully display a size, the system uses a smaller unit for that size. For example, if the unit is set to TB, precision is set to 1, and base is set to 10, the size 0.11709 TB is shown as
117.1 GB.
• Temperature Preference. Specifies the scale to use for temperature values: Celsius or Fahrenheit.
• Auto Sign Out. Select the amount of time that the user’s session can be idle before the user is automatically signed out (2–720 minutes). The default is 30 minutes.
• Locale. The user’s preferred display language, which overrides the system’s default display language.
Installed language sets include Chinese-Simplified, Chinese-Traditional, Dutch, English, French, German,
Italian, Japanese, Korean, and Spanish.
3. Click Add User.
To add an SNMPv3 user
1. In the Configuration View panel, right-click the system and select Configuration > Users > Add New User.
2. In the main panel, set the options:
• User Name (required). A user name is case sensitive; cannot already exist in the system; cannot include a comma, double quote, backslash, or space; and can have a maximum of 29 bytes.
NOTE: The user name admin is reserved for internal use.
• Password (required). A password is case sensitive and can include a maximum of 32 bytes using characters except a backslash, comma, or double quote. If the Authentication Type option is set to use authentication, this password is the authentication password and must include at least 8 characters.
• SNMPv3 User Definition. Select this checkbox to enable SNMP-user options and disable general-user options.
• SNMP user type. Select User Access to enable the user to view the SNMP MIB, or Trap Target to enable the user to receive SNMP trap notifications. If you select Trap Target you must set the Trap Host Address option.
• Authentication Type. Select whether to use MD5 or SHA authentication, or no authentication (None). The default is MD5. Authentication uses the user password.
• Privacy Type. Select whether to use DES or AES encryption, or no encryption (none). The default is none.
To use encryption you must also set the Privacy Password and Authentication Type options.
• Privacy Password. If the Privacy Type option is set to use encryption, specify an encryption password, which is case sensitive; can include a maximum of 32 bytes using characters except a backslash, comma, or double quote; and must include at least 8 characters.
• Trap Host Address. If you set the user type to Trap Target, specify the IP address of the host system that will receive SNMP traps.
3. Click Add User.
34 Configuring the system
Modifying users
You can change settings either for a general user that can access the WBI, CLI, FTP, or SMI-S interfaces, or for an
SNMPv3 user.
To modify a general user
1. In the Configuration View panel, right-click the system and select Configuration > Users > Modify User. A table displays details for each user. For each interface a user can access, a checkmark appears in the WBI, CLI,
SNMP, FTP, and SMI-S columns.
2. In the main panel, select the user to modify.
3. Set the options:
• Password. A password is case sensitive and can include a maximum of 32 bytes using characters except a backslash, comma, or double quote.
• SNMPv3 User Definition checkbox appears, but is enabled only for SNMP users.
• User Roles. Select Monitor or Manage. You cannot change the roles of user manage.
• Monitor. The user has access to the WBI and CLI. A user with role Monitor may view system settings but cannot change them.
• Manage. The user has access to the WBI, CLI, FTP interface, and SMI-S interface. A user with role
Manage may view and change system settings.
• User Type. Select an option to identify the user’s experience level: Standard, Advanced, or Diagnostic.
• WBI Access. Allows access to the web-based management interface.
• CLI Access. Allows access to the command-line management interface.
• FTP Access. Allows access to the FTP interface, which can be used instead of the WBI to install firmware updates and download logs.
• SMI-S Access. Allows access to the SMI-S interface, used for remote management of the system through your network.
• Base Preference. Select the base for entry and display of storage-space sizes. In base 2, sizes are shown as powers of 2, using 1024 as a divisor for each magnitude. In base 10, sizes are shown as powers of 10, using
1000 as a divisor for each magnitude. Operating systems usually show volume size in base 2. Disk drives usually show size in base 10. Memory (RAM and ROM) size is always shown in base 2.
• Precision Preference. Select the number of decimal places (1–10) for display of storage-space sizes.
• Unit Preference. The unit for display of storage-space sizes: Auto, TB, GB, or MB.
The Auto option lets the system determine the proper unit for a size. Based on the precision setting, if the selected unit is too large to meaningfully display a size, the system uses a smaller unit for that size. For example, if the unit is set to TB, precision is set to 1, and base is set to 10, the size 0.11709 TB is shown as
117.1 GB.
• Temperature Preference. Specifies the scale to use for temperature values: Celsius or Fahrenheit.
• Auto Sign Out. Select the amount of time that the user’s session can be idle before the user is automatically signed out (2–720 minutes). The default is 30 minutes.
• Locale. The user’s preferred display language, which overrides the system’s default display language.
Installed language sets include Chinese-Simplified, Chinese-Traditional, Dutch, English, French, German,
Italian, Japanese, Korean, and Spanish.
4. Click Modify User.
User changes take effect when the user next logs in.
To modify an SNMPv3 user
1. In the Configuration View panel, right-click the system and select Configuration > Users > Modify User. A table displays details for each user. SNMP3 users can only access the SNMP interface; the other columns are not applicable.
2. In the main panel, select the user to modify.
3. Set the options:
NEXIO 2300 Series WBI User Guide 35
• Password. A password is case sensitive and can include a maximum of 32 bytes using characters except a backslash, comma, or double quote. If the Authentication Type option is set to use authentication, this password is the authentication password and must include at least 8 characters.
• SNMP user type. Select User Access to enable the user to view the SNMP MIB, or Trap Target to enable the user to receive SNMP trap notifications. If you select Trap Target you must set the Trap Host Address option.
• Authentication Type. Select whether to use MD5 or SHA authentication, or no authentication (None). The default is MD5. Authentication uses the user password.
• Privacy Type. Select whether to use DES or AES encryption, or no encryption (none). The default is none.
To use encryption you must also set the Privacy Password and Authentication Type options.
• Privacy Password. If the Privacy Type option is set to use encryption, specify an encryption password, which is case sensitive; can include a maximum of 32 bytes using characters except a backslash, comma, or double quote; and must include at least 8 characters.
• Trap Host Address. If you set the user type to Trap Target, specify the IP address of the host system that will receive SNMP traps.
4. Click Modify User.
User changes take effect when the user next logs in.
Removing users
To remove a user
1. In the Configuration View panel, right-click the system and select Configuration > Users > Remove User. A table displays details for each user. For each interface a user can access, a checkmark appears in the WBI, CLI,
SNMP, FTP, and SMI-S columns.
2. In the main panel, select the user to remove. You cannot remove the manage user.
3. Click Remove User. A confirmation dialog appears.
4. Click Remove to continue; otherwise, click Cancel. If you click Remove, a processing dialog appears. When processing is complete, the user is removed from the table.
5. Click OK.
Configuring system settings
Changing the system date and time
You can enter values manually for the system date and time, or you can set the system to use NTP as explained in
About the system date and time on page 21.
To use manual date and time settings
1. In the Configuration View panel, right-click the system and select Configuration > System Settings > Date,
Time. The date and time options appear.
2. Set the options:
• Time. Enter the time in the format hh:mm:ss, where hh is the hour (0–23), mm is the minutes (0–59), and ss is the seconds (0–59).
• Month.
• Day.
• Year. Enter the year using four digits.
• Network Time Protocol (NTP). Select Disabled.
3. Click Apply.
To obtain the date and time from an NTP server
1. In the Configuration View panel, right-click the system and select Configuration > System Settings > Date,
Time. The date and time options appear.
2. Set the options:
• Network Time Protocol (NTP). Select Enabled.
36 Configuring the system
• NTP Time Zone Offset. Optional. The system’s time zone as an offset in hours, and optionally minutes, from UTC. For example: the Pacific Time Zone offset is -8 during Pacific Standard Time or -7 during
Pacific Daylight Time; the offset for Bangalore, India is +5:30.
• NTP Server Address. Optional. If the system should retrieve time values from a specific NTP server, enter the address of an NTP server. If no IP server address is set, the system listens for time messages sent by an
NTP server in broadcast mode.
3. Click Apply.
Changing host interface settings
The host interfaced settings should be set as described in the Farad Infrastructure Commissioning Checklist. Do not change the settings without the recommendation of Technical Support. To enable the system to communicate with hosts or with remote systems, you must configure the system’s host-interface options. There are options for
FC ports but not For SAS ports.
Each SAS port displays the text, “There are no configurable settings for SAS”. Click Next to continue.
To change FC host interface settings
1. In the Configuration View panel, right-click the system and select Configuration > System Settings > Host
Interfaces.
2. Set Speed. to auto (the default), which auto-negotiates the proper link speed with the host, or to 2 Gbit
(Gbit/s), 4 Gbit, or 8 Gbit. Because a speed mismatch prevents communication between the port and host, set a speed only if you need to force the port to use a known speed for testing, or if you need to specify a mutually supported speed for more than two FC devices connected in an arbitrated loop.
3. Set Connection Mode to loop, point-to-point, or auto (the default). Loop protocol can be used in a physical loop or in a direct physical connection between two devices. Point-to-point protocol can only be used on a direct physical connection between exactly two devices. Auto sets the mode based on the detected connection type.
4. Set Loop IDs, per controller, to use soft or hard target addressing:
• Soft target addressing (the default) enables a LIP to determine the loop ID. Use this setting if the loop ID is permitted to change after a LIP or power cycle.
• Hard target addressing requests a specific loop ID that should remain after a LIP or power cycle. If the port cannot acquire the specified ID, it is assigned a soft target address. Use this option if you want ports to have specific addresses, if your system checks addresses in reverse order (lowest address first), or if an application requires that specific IDs be assigned to recognize the controller.
5. Click Apply. If you changed a loop ID setting, a message specifies that you must restart the controller to make the change take effect. An asterisk indicates that the value shown will be changed.
Changing network interface settings
You can configure addressing parameters for each controller’s network port. You can set static IP values or use
DHCP. Static IP values are required for Farad Storage Manager.
In DHCP mode, network port IP address, subnet mask, and gateway values are obtained from a DHCP server if one is available. If a DHCP server is unavailable, current addressing is unchanged. You must have some means of determining what addresses have been assigned, such as the list of bindings on the DHCP server.
Each controller has the following factory-default IP settings:
• DHCP: disabled
• Controller A IP address: 10.0.0.2
• Controller B IP address: 10.0.0.3
• IP subnet mask: 255.255.255.0
• Gateway IP address: 10.0.0.1
When DHCP is enabled, the following initial values are set and remain set until the system is able to contact a
DHCP server for new addresses:
• Controller IP addresses: 169.254.x.x (where the value of x.x is the lowest 16 bits of the controller serial number)
NEXIO 2300 Series WBI User Guide 37
• IP subnet mask: 255.255.0.0
• Gateway IP address: 0.0.0.0
169.254.x.x addresses (including gateway 169.254.0.1) are on a private subnet that is reserved for unconfigured systems and the addresses are not routable. This prevents the DHCP server from reassigning the addresses and possibly causing a conflict where two controllers have the same IP address. As soon as possible, change these IP values to proper values for your network.
CAUTION: Changing IP settings can cause management hosts to lose access to the storage system.
To use DHCP to obtain IP values for network ports
1. In the Configuration View panel, right-click the system and select Configuration > System Settings > Network
Interfaces.
2. Set the IP address source to DHCP.
3. Click Apply. If the controllers successfully obtain IP values from the DHCP server, the new IP values are displayed.
4. Record the new addresses.
5. Sign out and try to access RAIDar using the new IP addresses.
To set static IP values for network ports
1. Determine the IP address, subnet mask, and gateway values to use for each controller.
2. In the Configuration View panel, right-click the system and select Configuration > System Settings > Network
Interfaces.
3. Set the IP address source to manual.
4. Set the options for each controller. You must set a unique IP address for each network port. All fields are required.
5. Record the IP values you assign.
6. Click Apply.
7. Sign out and try to access RAIDar using the new IP addresses.
Setting system information
To set system information
1. In the Configuration View panel, right-click the system and select Configuration > System Settings > System
Information.
2. In the main panel, set the System Name, System Contact Person, System Location, and System Information description. Each value can include a maximum of 79 bytes, using characters except double quote or backslash. The name is shown in the browser title bar or tab. The name, location, and contact are included in event notifications. All four values are recorded in system debug logs for reference by service personnel.
3. Click Apply.
Configuring advanced settings
Changing disk settings
See the Farad Infrastructure Commissioning Checklist for more information. Do not change the disk settings away from the values specified in the Commissioning checklist unless specifically instructed to do so by Technical
Support.
Configuring SMART
SMART provides data that enables you to monitor disks and analyze why a disk failed. When SMART is enabled, the system checks for SMART events one minute after a restart and every five minutes thereafter. SMART events are recorded in the event log.
38 Configuring the system
To change the SMART setting
1. In the Configuration View panel, right-click the system and select Configuration > Advanced Settings > Disk.
2. Set SMART Configuration to either:
• Don’t Modify. Allows current disks to retain their individual SMART settings and does not change the setting for new disks added to the system.
• Enabled. Enables SMART for all current disks after the next rescan and automatically enables SMART for new disks added to the system. This option is the default.
• Disabled. Disables SMART for all current disks after the next rescan and automatically disables SMART for new disks added to the system.
3. Click Apply.
Configuring dynamic spares (Not supported in Farad Gen 2)
The dynamic spares feature lets you use all of your disks in fault-tolerant vdisks without designating a disk as a spare. With dynamic spares enabled, if a disk fails and you replace it with a compatible disk, the storage system rescans the bus, finds the new disk, automatically designates it a spare, and starts reconstructing the vdisk. A compatible disk has enough capacity to replace the failed disk and is the same type (SAS SSD, enterprise SAS, or midline SAS). If a dedicated spare, global spare, or compatible available disk is already present, the dynamic spares feature uses that disk to start the reconstruction and the replacement disk can be used for another purpose.
To change the dynamic spares setting
1. In the Configuration View panel, right-click the system and select Configuration > Advanced Settings > Disk.
2. Either select (enable) or clear (disable) the Dynamic Spare Capability option.
3. Click Apply.
Configuring DSD for available disks and global spares (Not supported in Farad Gen 2)
The DSD feature monitors disk activity within system enclosures and spins down inactive disks to conserve energy. You can enable or disable DSD for available disks and global spares, and set the period of inactivity after which available disks and global spares automatically spin down.
To configure a time period to suspend and resume DSD for all disks, see
Scheduling DSD for all disks on page 39.
To configure DSD for a vdisk, see
Configuring DSD for a vdisk (Not supported in Farad Gen 2) on page 45.
DSD affects disk operations as follows:
• Spun-down disks are not polled for SMART events.
• Operations requiring access to disks may be delayed while the disks are spinning back up.
To configure DSD for available disks and global spares
1. In the Configuration View panel, right-click the local system and select Configuration > Advanced Settings >
Disk.
2. Set the options:
• Either select (enable) or clear (disable) the Available and Spare Drive Spin Down Capability option. If you are enabling DSD, a warning prompt appears; to use DSD, click Yes; to leave DSD disabled, click No.
• Set the Drive Spin Down Delay (minutes), which is the period of inactivity after which available disks and global spares automatically spin down, from 1–360 minutes. If DSD is enabled and no delay value is set, the default is 15 minutes. The value 0 disables DSD.
3. Click Apply. When processing is complete a success dialog appears.
4. Click OK.
Scheduling DSD for all disks
For all disks that are configured to use DSD, you can configure a time period to suspend and resume DSD so that disks remain spun-up during hours of frequent activity.
To configure DSD for a vdisk, see
Configuring DSD for a vdisk (Not supported in Farad Gen 2) on page 45. To
(Not supported in Farad Gen 2) on page 39.
NEXIO 2300 Series WBI User Guide 39
DSD affects disk operations as follows:
• Spun-down disks are not polled for SMART events.
• Operations requiring access to disks may be delayed while the disks are spinning back up.
• If a suspend period is configured and it starts while a disk has started spinning down, the disk spins up again.
To schedule DSD for all disks
1. In the Configuration View panel, right-click the local system and select Configuration > Advanced Settings >
Disk.
2. Set the options:
• Select the Drive Spin Down Suspend Period option.
• Set a time to suspend and a time to resume DSD. For each, enter hour and minutes values and select either
AM, PM, or 24H (24-hour clock).
• If you want the schedule to apply only Monday through Friday, select the Exclude Weekend Days from
Suspend Period option.
3. Click Apply. When processing is complete a success dialog appears.
4. Click OK.
Configuring the EMP polling rate
You can change the interval at which the storage system polls each attached EMP for status changes. Typically you can use the default setting.
• Increasing the interval might slightly improve processing efficiency, but changes in device status are communicated less frequently. For example, this increases the amount of time before LEDs are updated to reflect status changes.
• Decreasing the interval slightly decreases processing efficiency, but changes in device status are communicated more frequently. For example, this decreases the amount of time before LEDs are updated to reflect status changes.
To change the EMP polling rate
1. In the Configuration View panel, right-click the system and select Configuration > Advanced Settings > Disk.
2. Set the EMP Polling Rate interval. The options are 5 Seconds, 10 Seconds, 30 Seconds, 1 Minute, 5 Minutes,
10 Minutes, 15 Minutes, 20 Minutes, 25 Minutes, 30 Minutes, 45 Minutes, or 60 Minutes.
The default is 5 seconds.
3. Click Apply.
Changing system cache settings
See the Farad Infrastructure Commissioning Checklist for more information. Do not change the cache settings away from values specified in the Commissioning checklist unless specifically instructed to do so by Technical
Support.
Changing the synchronize-cache mode
You can control how the storage system handles the
SCSI SYNCHRONIZE CACHE
command. Typically you can use the default setting. However, if the system has performance problems or problems writing to databases or other applications, contact technical support to determine if you should change this option.
To change the synchronize-cache mode
1. In the Configuration View panel, right-click the system and select Configuration > Advanced Settings >
Cache.
2. Set Sync Cache Mode to either:
• Immediate. Good status is returned immediately and cache content is unchanged. This is the default.
• Flush to Disk. Good status is returned only after all write-back data for the specified volume is flushed to disk.
3. Click Apply.
40 Configuring the system
Changing the missing LUN response
Some operating systems do not look beyond LUN 0 if they do not find a LUN 0 or cannot handle noncontiguous
LUNs. The Missing LUN Response option handles these situations by enabling the host drivers to continue probing for LUNs until they reach the LUN to which they have access.
This option controls the SCSI sense data returned for volumes that are not accessible because they don’t exist or have been hidden through volume mapping (this does not apply to volumes of offline vdisks). Use the default value, Not Ready, unless the system is used in a VMware environment or a service technician asks you to change it to work around a host driver problem.
To change the missing LUN response
1. In the Configuration View panel, right-click the system and select Configuration > Advanced Settings >
Cache.
2. Set Missing LUN Response to either:
• Not Ready. Sends a reply that there is a LUN where a gap has been created but that it’s “not ready.” Sense data returned is a Sense Key of 2h and an ASC/ASCQ of 04/03. This option is the default.
• Illegal Request. Sends a reply that there is a LUN but that the request is “illegal.” Sense data returned is a
Sense Key of 5h and an ASC/ASCQ of 25/00. If the system is used in a VMware environment, use this option.
3. Click Apply.
Controlling host access to the system’s write-back cache setting
You can prevent hosts from using
SCSI MODE SELECT
commands to change the system’s write-back cache setting. Some operating systems disable write cache. If host control of write-back cache is disabled, the host cannot modify the cache setting. The default is disabled.
This option is useful in some environments where the host disables the system’s write-back cache, resulting in degraded performance.
To change host access to the write-back cache setting
1. In the Configuration View panel, right-click the system and select Configuration > Advanced Settings >
Cache.
2. Either select (enable) or clear (disable) the Host Control of Write-Back Cache option.
3. Click Apply.
Independent Cache Performance Mode
By default, controller failover is enabled and data in a controller’s write-back cache is mirrored to the partner controller. You can enable Independent Cache Performance Mode, in which controller failover is disabled and data in a controller’s write-back cache is not mirrored to the partner controller. This improves write performance at the risk of losing unwritten data if a controller failure occurs while there is data in controller cache.
To change Independent Cache Performance Mode settings
1. In the Configuration View panel, right-click the system and select Configuration > Advanced Settings >
Cache.
2. Either select (enable) or clear (disable) the Independent Cache Performance Mode option.
3. Click Apply.
Changing AWT cache triggers and behaviors
You can set conditions that cause (“trigger”) a controller to change the cache mode from write-back to write-through, as described in
About volume cache options on page 17. You can also specify actions for the
system to take when write-through caching is triggered.
To change AWT cache triggers and behaviors
1. In the Configuration View panel, right-click the system and select Configuration > Advanced Settings >
Cache.
2. In the Auto-Write Through Cache Trigger Conditions section, either select (enable) or clear (disable) the options:
NEXIO 2300 Series WBI User Guide 41
• Controller Failure. Changes to write-through if a controller fails. The default is disabled.
• Cache Power. Changes to write-through if cache backup power is not fully charged or fails. The default is enabled.
• CompactFlash. Changes to write-through if CompactFlash memory is not detected during POST, fails during POST, or fails while the controller is under operation. The default is enabled.
• Power Supply Failure. Changes to write-through if a PSU fails. The default is disabled.
• Fan Failure. Changes to write-through if a cooling fan fails. The default is disabled.
• Overtemperature Failure. Forces a controller shutdown if a temperature is detected that exceeds system threshold limits. The default is disabled.
3. In the Auto-Write Through Cache Behaviors section, either select (enable) or clear (disable) the options:
• Revert when Trigger Condition Clears. Changes back to write-back caching after the trigger condition is cleared. The default is enabled.
• Notify Other Controller. Notifies the partner controller that a trigger condition occurred. Enable this option to have the partner also change to write-through mode for better data protection. Disable this option to allow the partner continue using its current caching mode for better performance. The default is disabled.
4. Click Apply.
Configuring PFU
See the Farad Infrastructure Commissioning Checklist for more information. Do not change the PFU settings away from values specified in the Commissioning checklist unless specifically instructed to do so by Technical
Support.
In a dual-controller system in which PFU is enabled, when you update firmware on one controller, the system automatically updates the partner controller.
IMPORTANT: Disable PFU only if requested by a service technician.
To change the PFU setting
1. In the Configuration View panel, right-click the system and select Configuration > Advanced Settings >
Firmware.
2. Either select (enable) or clear (disable) the PFU option.
3. Click Apply.
Configuring system utilities
See the Farad Infrastructure Commissioning Checklist for more information. Do not change the system utility settings away from values specified in the Commissioning checklist unless specifically instructed to do so by
Technical Support.
Configuring background scrub for vdisks (Not supported in Farad Gen 2)
You can enable or disable whether the system continuously analyzes disks in vdisks to find and fix disk errors.
This command will fix parity mismatches for RAID 3, 5, 6, and 50; mirror mismatches for RAID 1 and 10; and media errors for all RAID levels.
You can use a vdisk while it is being scrubbed. Background vdisk scrub runs at background utility priority, which reduces to no activity if processor usage is above a certain percentage or if I/O is occurring on the vdisk being scrubbed. A vdisk scrub may be in process on multiple vdisks at once. A new vdisk will first be scrubbed 20 minutes after creation. After a vdisk is scrubbed, scrub will start again after the interval specified by the Vdisk
Scrub Interval option.
When a scrub is complete, event 207 is logged and specifies whether errors were found and whether user action is required.
Enabling background vdisk scrub is recommended for SAS disks.
42 Configuring the system
TIP: If you choose to disable background vdisk scrub, you can still scrub a selected vdisk by using Tools >
).
To configure background scrub for vdisks
1. In the Configuration View panel, right-click the system and select Configuration > Advanced Settings >
System Utilities.
2. Set the options:
• Either select (enable) or clear (disable) the Vdisk Scrub option. The default is disabled.
• Set the Vdisk Scrub Interval, which is the interval between background vdisk scrub finishing and starting again, from 1–360 hours; the default is 24 hours.
3. Click Apply.
Configuring background scrub for disks not in vdisks
You can enable or disable whether the system continuously analyzes disks that are not in vdisks to find and fix disk errors. The interval between background disk scrub finishing and starting again is 24 hours.
Enabling background disk scrub is recommended for SAS disks.
To configure background scrub for disks not in vdisks
1. In the Configuration View panel, right-click the system and select Configuration > Advanced Settings >
System Utilities.
2. Either select (enable) or clear (disable) the Disk Scrub option. The default is disabled.
3. Click Apply.
Configuring utility priority
You can change the priority at which the Verify, Reconstruct, Expand, and Initialize utilities run when there are active I/O operations competing for the system’s controllers.
To change the utility priority
1. In the Configuration View panel, right-click the system and select Configuration > Advanced Settings >
System Utilities.
2. Set Utility Priority to either:
• High. Use when your highest priority is to get the system back to a fully fault-tolerant state. This causes heavy I/O with the host to be slower than normal.
• Medium. Use when you want to balance data streaming with data redundancy.
• Low. Use when streaming data without interruption, such as for a web server, is more important than data redundancy. This enables a utility such as Reconstruct to run at a slower rate with minimal effect on host
I/O.
3. Click Apply.
Enabling/disabling managed logs
You can enable or disable the managed logs feature, which allows log files to be transferred from the storage system to a log-collection system to avoid losing diagnostic data. For an overview of the managed logs feature,
as described in
Configuring email notification on page 32 and Configuring SNMP notification on page 32. After
enabling log management, you can test it as described in
Testing notifications on page 65.
To enable or disable managed logs
1. In the Configuration View panel, right-click the system and select Configuration > Advanced Settings >
System Utilities.
2. Either select (enable) or clear (disable) the Managed Logs option. The default is disabled.
3. Click Apply.
NEXIO 2300 Series WBI User Guide 43
Configuring an existing vdisk
Managing dedicated spares (Not supported in Farad Gen 2)
You can assign a maximum of four available disks to a fault-tolerant vdisk (RAID 1, 3, 5, 6, 10, 50) for use as spares by that vdisk only. A spare must be the same type (SAS SSD, enterprise SAS, or midline SAS) as other disks in the vdisk, and have sufficient capacity to replace the smallest disk in the vdisk.
If a disk in the vdisk fails, a dedicated spare is automatically used to reconstruct the vdisk. A fault-tolerant vdisk other than RAID6 becomes Critical when one disk fails. A RAID6 vdisk becomes Degraded when one disk fails and Critical when two disks fail. After the vdisk’s parity or mirror data is completely written to the spare, the vdisk returns to fault-tolerant status. For RAID50 vdisks, if more than one sub-vdisk becomes critical, reconstruction and use of assigned spares occur in the order sub-vdisks are numbered.
To change a vdisk’s spares
1. In the Configuration View panel, right-click a vdisk and select Configuration > Manage Dedicated Spares. The main panel shows information about the selected vdisk, its spares, and all disks in the system. Existing spares are labeled SPARE.
• In the Disk Sets table, the number of white slots in the Disks column of the SPARE rowe shows how many spares you can add to the vdisk.
• In the Tabular enclosure list or Graphical enclosure view, only existing spares and suitable available disks are selectable.
2. To add a spare, select (enable) it. To remove a spare, clear (disable) it.
3. Select spares to remove, disks to add as spares, or both.
4. Click Modify Spares. If the task succeeds, the panel is updated to show which disks are now spares for the vdisk.
Changing a vdisk’s name
To change a vdisk’s name
1. In the Configuration View panel, right-click a vdisk and select Configuration > Modify Vdisk Name. The main panel shows the vdisk’s name.
2. Enter a new name. A vdisk name is case sensitive; cannot already exist in the system; and cannot include a comma, double quote, or backslash. The name you enter can have a maximum of 17 bytes.
3. Click Modify Name. The new name appears in the Configuration View panel.
Changing a vdisk’s owner
Each vdisk is owned by one of the controllers, A or B, known as the preferred owner. Typically, you should not need to change vdisk ownership.
When a controller fails, the partner controller assumes temporary ownership of the failed controller’s vdisks and resources, becoming the current owner. If the system uses a fault-tolerant cabling configuration, both controllers’
LUNs are accessible through the partner.
CAUTION: Do not change the owning controller for a vdisk unless specifically directed to do so by Technical
Support.
Changing the owner of a vdisk does not affect the mappings volumes in that vdisk.
To change a vdisk’s owner
1. In the Configuration View panel, right-click a vdisk and select Configuration > Modify Vdisk Owner. The main panel shows the vdisk’s owner.
2. Select a new owner.
3. Click Modify Owner. A confirmation dialog appears.
44 Configuring the system
4. Click Yes to continue; otherwise, click No. If you click Yes, a processing dialog appears. When processing is complete a success dialog appears.
5. Click OK.
Configuring DSD for a vdisk (Not supported in Farad Gen 2)
The DSD feature monitors disk activity within system enclosures and spins down inactive disks to conserve energy. For a specific vdisk, you can enable or disable DSD and set the period of inactivity after which the vdisk’s disks and dedicated spares automatically spin down.
To configure a time period to suspend and resume DSD for all vdisks, see
DSD affects disk operations as follows:
• Spun-down disks are not polled for SMART events.
• Operations requiring access to disks may be delayed while the disks are spinning back up.
• If a suspend period is configured and it starts while a vdisk has started spinning down, the vdisk spins up again.
To configure DSD for a vdisk
1. In the Configuration View panel, right-click a vdisk and select Configuration > Configure Vdisk Drive Spin
Down.
2. Set the options:
• Either select (enable) or clear (disable) the Enable Drive Spin Down option. The default is disabled.
• Set the Drive Spin Down Delay (minutes), which is the period of inactivity after which the vdisk’s disks and dedicated spares automatically spin down, from 1–360 minutes. If DSD is enabled and no delay value is set, the default is 15 minutes. Entering 0 results in an error message, requesting that you change the delay to a value between 1 and 360 minutes
3. Click Apply. When processing is complete a success dialog appears.
4. Click OK.
Configuring an existing volume
Changing a volume’s name
To change a volume’s name
1. In the Configuration View panel, right-click a volume and select Configuration > Modify Volume Name.
2. Enter a new name. A volume name is case sensitive; cannot already exist in a vdisk; cannot include a comma, double quote, or backslash; and can have a maximum of 20 bytes.
3. Click Modify Name. The new name appears in the Configuration View panel.
Changing a volume’s cache settings
CAUTION:
• Do not change the cache settings away from values specified in the Commissioning checklist unless specifically instructed to do so by Technical Support.
To change a volume’s cache settings
1. In the Configuration View panel, right-click a volume and select Configuration > Modify Volume Cache
Settings.
2. In the main panel, set the read-ahead cache options:
• Write Policy. Select Write-back or Write-through. The default is Write-back.
NEXIO 2300 Series WBI User Guide 45
• Write Optimization. Select Standard, Atomic Write, or No-mirror. The default is Standard.
• Read Ahead Size. Select Default, Disabled, Maximum, or a specific size (64, 128, 256, or 512 KB; 1, 2, 4,
8, 16, or 32 MB).
3. Click Modify Cache Settings.
46 Configuring the system
3 Provisioning the system
NOTE: Please setup, configure and provision the system using instructions supplied in the Farad Infrastructure
Commissioning Checklist. The Provisioning Wizard is generally not used to set up Farad Gen 2.
Using the Provisioning Wizard
The Provisioning Wizard helps you create a vdisk with volumes and to map the volumes to hosts. Before using this wizard, read documentation for your product to learn about vdisks, volumes, and mapping. Then plan the vdisks and volumes you want to create and the default mapping settings you want to use.
The wizard guides you through the following steps. For each step you can view help by clicking the help icon in the wizard panel. As you complete steps they are highlighted at the bottom of the panel. If you cancel the wizard at any point, no changes are made.
• Specify a name and RAID level for the vdisk
• Select disks to use in the vdisk
• Specify the number and size of volumes to create in the vdisk
• Specify the default mapping for access to the volume by hosts
• Confirm changes and apply them
Step 1: Starting the wizard
1. In the Configuration View panel, right-click the system and select either Provisioning > Provisioning Wizard or Wizards > Provisioning Wizard. The wizard panel appears, displaying Step 1 of 6: Introduction.
2. Review the text, then click Next to continue.
Step 2: Specifying the vdisk name and RAID level
In the wizard panel, Step 2 of 6: Name and RAID Level displays.
A vdisk is a virtual disk that is composed of one or more disks, and has the combined capacity of those disks. The number of disks that a vdisk can contain is determined by its RAID level. All disks in a vdisk must be the same type (SAS SSD, enterprise SAS, or midline SAS). A maximum of 16 vdisks per controller can exist.
A vdisk can contain different models of disks, and disks with different capacities. For example, a vdisk can include a 500 GB disk and a 750 GB disk. If you mix disks with different capacities, the smallest disk determines the logical capacity of all other disks in the vdisk, regardless of RAID level. For example, if a RAID0 vdisk contains one 500 GB disk and four 750 GB disks, the capacity of the vdisk is equivalent to approximately five 500
GB disks. To maximize capacity, use disks of similar size. For greatest reliability, use disks of the same size and rotational speed.
In a single-controller system, all vdisks are owned by that controller. In a dual-controller system, when a vdisk is created the system automatically assigns the owner to balance the number of vdisks each controller owns; or, you can select the owner. Typically it doesn’t matter which controller owns a vdisk.
In a dual-controller system, when a controller fails, the partner controller assumes temporary ownership of the failed controller’s vdisks and resources. If the system uses a fault-tolerant cabling configuration, both controllers’
LUNs are accessible through the partner.
When you create a vdisk you can also create volumes within it. A volume is a logical subdivision of a vdisk, and can be mapped to controller host ports for access by hosts. The storage system presents only volumes, not vdisks, to hosts.
NEXIO 2300 Series WBI User Guide 47
To create a vdisk
(See the Farad Infrastructure Commissioning Checklist for details on creating and naming vdisks.)
1. Set the options:
• Vdisk name (required). This field is populated with a default name. You may optionally change the default name for the vdisk. A vdisk name is case sensitive; cannot already exist in the system; and cannot include a comma, double quote, or backslash. The name you enter can have a maximum of 17 bytes.
• Assign to. If the system is operating in Active-Active ULP mode, optionally select a controller to be the preferred owner for the vdisk. Auto (the default) automatically assigns the owner to load-balance vdisks between controllers. If the system is operating in Single Controller mode, the Assign to setting is ignored and the system automatically load-balances vdisks in anticipation of the insertion of a second controller in the future.
• RAID Level (required). Select a RAID level for the vdisk.
• Number of sub-vdisks. (required) This field is populated with a default number. For a RAID10 or RAID50 vdisk, you may optionally change the number of sub-vdisks that the vdisk should contain.
• Chunk size. For RAID 3, 5, 6, 10, or 50, optionally set the amount of contiguous data that is written to a vdisk member before moving to the next member of the vdisk. For RAID50, this option sets the chunk size of each RAID5 sub-vdisk. The chunk size of the RAID50 vdisk is calculated as: configured-chunk-size x
(subvdisk-members - 1). For NRAID and RAID1, chunk size has no meaning and is therefore disabled.
The default size is 64KB.
2. Click Next to continue.
Step 3: Selecting disks
In the wizard panel, Step 3 of 6: Select Disks displays.
Select disks to include in the vdisk. The Disk Selection Sets table has one row for each sub-vdisk in a RAID10 or
RAID50 vdisk, or a single row for a vdisk having another RAID level. The table also has a SPARE row where you can assign dedicated spares to the vdisk. In each row, the Disks field shows how many disks you can, and have, assigned. As you select disks, the table shows the amount of storage space in the vdisk. For descriptions of
storage-space color codes, see About storage-space color codes on page 22.
The Tabular Enclosures Front View tab shows all available disks in all enclosures in a table, displaying Health,
Name, Type, State, Size, Enclosure, Serial Number, and Status. The Graphical tab shows all disk information graphically, displaying the state for each disk (VDISK, AVAIL, SPARE). Only available disks can be selected.
Disks you select are highlighted and color-coded to match the rows in the Disk Selection Sets table. Based on the type of disk you select first (SAS SSD, enterprise SAS, or midline SAS), only available disks of that type become selectable; disks of different types cannot be mixed in a vdisk.
To select disks and spares
1. Select disks to populate each vdisk row. When you have selected enough disks, a checkmark appears in the table’s Complete field.
2. Optionally select up to four dedicated spares for the vdisk.
3. Click Next to continue.
Step 4: Defining volumes
In the wizard panel, Step 4 of 6: Define Volumes displays.
A volume is a logical subdivision of a vdisk and can be mapped to controller host ports for access by hosts. A mapped volume provides the storage for a file system partition you create with your operating system or third-party tools. The storage system presents only volumes, not vdisks, to hosts.
You can create multiple volumes with the same base name, size, and default mapping settings. If you choose to define volumes in this step, you will define their mapping settings in the next step.
48 Provisioning the system
To define volumes
1. Number of volumes to create (required). Specify the number of volumes to create. If you do not want to create volumes, enter 0. After changing the value, press Tab.
2. Volume size. Specify the size of each volume. The default is the total space of the vdisk divided by the number of volumes.
3. Base name for volumes. Specify the base name for the volumes. A volume name is case sensitive; cannot already exist in a vdisk; cannot include a comma, double quote, or backslash; and can have a maximum of 20 bytes.
4. Click Next to continue.
Step 5: Setting the default mapping
In the wizard panel, Step 5 of 6: Set the Base Mapping for Volumes displays.
Specify default mapping settings to control whether and how hosts will be able to access the vdisk’s volumes.
These settings include:
• A LUN used to identify a mapped volume to hosts. Both controllers share one set of LUNs. Each LUN can be assigned as the default LUN for only one volume in the storage system; for example, if LUN 5 is the default for Volume1, LUN5 cannot be the default LUN for any other volume.
• The level of access — read-write, read-only, or no access — that hosts will have to each volume. When a mapping specifies no access, the volume is masked.
• Controller host ports through which hosts will be able to access each volume. To maximize performance, it is recommended to map a volume to at least one host port on the controller that the volume’s vdisk is assigned to.
To sustain I/O in the event of controller failure, it is recommended to map to at least one host port on each controller.
After a volume is created you can change its default mapping, and create, modify, or delete explicit mappings. An
explicit mapping overrides the volume’s default mapping for a specific host.
NOTE: When mapping a volume to a host using the Linux ext3 file system, specify read-write access; otherwise, the file system will be unable to mount/present/map the volume and will report an error such as
“unknown partition table.”
To specify the default mapping
1. Select Map.
2. Set the starting LUN for the volumes. If this LUN is available, it will be assigned to the first volume and the next available LUNs in sequence will be assigned to any remaining volumes.
3. In the enclosure view or list, select controller host ports through which attached hosts can access each volume.
4. Select the access level that hosts will have to each volume: read-write, read-only, or no-access (masked). The default is read-write.
5. Click Next to continue.
Step 6: Confirming vdisk settings
In the wizard panel, Step 6 of 6: Confirm the Vdisk Settings displays with a table listing all the values selected in the wizard.
Confirm that the values listed in the wizard panel are correct.
• If they are not correct, click Previous to return to previous steps and make necessary changes.
• If they are correct, click Finish to apply the setting changes and finish the wizard.
Creating a vdisk
To create a vdisk
See the Farad Infrastructure Commissioning Checklist for details on creating and naming vdisks.
NEXIO 2300 Series WBI User Guide 49
1. In the Configuration View panel, right-click the system or Vdisks and then select Provisioning > Create Vdisk.
2. In the main panel set the options:
• Vdisk name (required). This field is populated with a default name. You may optionally change the default name for the vdisk. A vdisk name is case sensitive; cannot already exist in the system; and cannot include a comma, double quote, or backslash. The name you enter can have a maximum of 17 bytes.
• Assign to. If the system is operating in Active-Active ULP mode, optionally select a controller to be the preferred owner for the vdisk. Auto (the default) automatically assigns the owner to load-balance vdisks between controllers. If the system is operating in Single Controller mode, the Assign to setting is ignored and the system automatically load-balances vdisks in anticipation of the insertion of a second controller in the future.
• RAID Level. Select a RAID level for the vdisk.
• Number of Sub-vdisks. For a RAID10 or RAID50 vdisk, optionally change the number of sub-vdisks that the vdisk should contain.
• Chunk size. For RAID 3, 5, 6, 10, or 50, optionally set the amount of contiguous data that is written to a vdisk member before moving to the next member of the vdisk. For RAID50, this option sets the chunk size of each RAID5 sub-vdisk. The chunk size of the RAID50 vdisk is calculated as: configured-chunk-size x
(subvdisk-members - 1). For NRAID and RAID1, chunk size has no meaning and is therefore disabled.
The default size is 64KB.
• Online Initialization. If this option is enabled, you can use the vdisk while it is initializing but because the verify method is used to initialize the vdisk, initialization takes more time. If this option is disabled, you must wait for initialization to complete before using the vdisk, but initialization takes less time. Online initialization is fault tolerant.
3. Select disks to include in the vdisk. The Disk Selection Sets table has one row for each sub-vdisk in a RAID10 or RAID50 vdisk, or a single row for a vdisk having another RAID level. The table also has a SPARE row where you can assign dedicated spares to the vdisk. In each row, the Disks field shows how many disks you can, and have, assigned. As you select disks, the table shows the amount of storage space in the vdisk. For
descriptions of storage-space color codes, see About storage-space color codes on page 22.
The Tabular Enclosures Front View tab shows all available disks in all enclosures in a table, displaying Health,
Name, Type, State Size, Enclosure, Serial Number, and Status. The Graphical tab shows all disk information graphically. Disks you select are highlighted and color-coded to match the rows in the Disk Selection Sets table. Based on the type of disk you select first (SAS SSD, enterprise SAS, or midline SAS), only available disks of that type become selectable; disks of different types cannot be mixed in a vdisk.
To select disks and spares:
• Select disks to populate each vdisk row. When you have selected enough disks, a checkmark appears in the table’s Complete field.
• Optionally select up to four dedicated spares for the vdisk.
4. Click Create Vdisk. If the task succeeds, the new vdisk appears in the Configuration View panel.
Deleting vdisks
CAUTION: Deleting a vdisk removes all of its volumes and their data.
To delete vdisks
1. Verify that hosts are not accessing volumes in the vdisks that you want to delete.
2. In the Configuration View panel, either:
• Right-click the system or Vdisks and then select Provisioning > Delete Vdisks.
• Right-click a vdisk and select Provisioning > Delete Vdisk.
3. In the main panel, select the vdisks to delete. To select or clear all vdisks, toggle the checkbox in the heading row.
4. Click Delete Vdisk(s). A confirmation dialog appears.
5. Click Delete to continue; otherwise, click Cancel. If you click Delete, a processing dialog appears. If the task succeeds, an overview panel and a success dialog appear.
50 Provisioning the system
6. Click OK. As processing completes, the deleted items are removed from the Configuration View panel.
Managing global spares
You can designate six global spares per Farad Gen 2 stack. If a disk in any fault-tolerant vdisk (RAID 1, 3, 5, 6,
10, 50) fails, a global spare is automatically used to reconstruct the vdisk. At least one vdisk must exist before you can add a global spare. A spare must have sufficient capacity to replace the smallest disk in an existing vdisk.
The vdisk remains in critical status until the parity or mirror data is completely written to the spare, at which time the vdisk returns to fault-tolerant status. For RAID50 vdisks, if more than one sub-vdisk becomes critical, reconstruction and use of spares occur in the order sub-vdisks are numbered.
To change the system’s global spares
1. In the Configuration View panel, right-click the system and select Provisioning > Manage Global Spares. The main panel shows information about available disks in the system. Existing spares are labeled GLOBAL SP.
• In the Disk Sets table, the number of white slots in the Disks field shows how many spares you can add.
• The Tabular Enclosures Front View tab shows all available disks in all enclosures in a table. The Graphical tab shows all disk information graphically. Disks you select are highlighted and color-coded to match the rows in the Disk Selection Sets table.
2. Select spares to remove, disks to add as spares, or both.
3. Click Modify Spares. If the task succeeds, the panel is updated to show which disks are now global spares.
Creating a volume set (Not supported in Farad Gen 2)
In a vdisk that has sufficient free space, you can create multiple volumes with the same base name and size.
Optionally, you can specify a default mapping for the volumes; otherwise, they will be created unmapped.
To create a volume set
1. In the Configuration View panel, right-click a vdisk and select Provisioning > Create Volume Set.
2. In the main panel, set the options:
• Volume Set Base-name (required). This field is populated with a default name. You may optionally change the base name for the volumes. The volume names will consist of the base name and a number that increments from 0000. If a name in the series is already in use, the next name in the series is assigned. For example, for a two-volume set starting with Volume0000, if Volume0001 already exists, the second volume is named Volume0002. A base name is case sensitive; cannot already be used by another vdisk; cannot include a comma, double quote, or backslash; and can have a maximum of 16 bytes.
• Total Volumes. Specify the number of volumes to create. Volumes are created up to the maximum number supported per vdisk.
• Size. Optionally change the volume size. The default size is the total space divided by the number of volumes.
• Map. Select this option to specify a default mapping for the volumes:
• LUN (required). If the access level is set to read-write or read-only, set a LUN for the first volume. The next available LUN is assigned to the next volume mapped through the same ports. If a LUN to be assigned to a volume is already in use, that volume and any subsequent volumes are not mapped.
• Access. Select the access level that hosts will have to the volumes. The default is read-write.
• In the enclosure view or list, select controller host ports through which attached hosts can access the volumes.
3. Click Apply. If the task succeeds, the new volumes appear in the Configuration View panel.
Creating a volume
You can add a volume to a vdisk that has sufficient free space, and define default mapping settings.
To create a volume in a vdisk
See the Farad Infrastructure Commissioning Checklist for details on creating and naming volumes.
1. In the Configuration View panel, right-click a vdisk and select Provisioning > Create Volume.
NEXIO 2300 Series WBI User Guide 51
2. In the main panel, set the options:
• Volume name (required). This field is populated with a default name. You may optionally change the default name. A volume name is case sensitive; cannot already exist in a vdisk; cannot include a comma, double quote, or backslash; and can have a maximum of 20 bytes.
• Size. Optionally change the default size, which is all free space in the vdisk.
• Map. Select this option to change the default mapping for the volume:
• Access. Select the access level that hosts will have to the volume.
• LUN. If the access level is set to read-write or read-only, set a LUN for the volume.
• In the enclosure view or list, select controller host ports through which attached hosts can access the volume.
3. Click Apply. If the task succeeds, the new volume appears in the Configuration View panel.
Deleting volumes
You can use the Delete Volumes panel to delete volumes.
CAUTION: Deleting a volume removes its mappings and deletes its data.
To delete volumes
1. Verify that hosts are not accessing the volumes that you want to delete.
2. In the Configuration View panel, either:
• Right-click the system or Vdisks or a vdisk and then select Provisioning > Delete Volumes.
• Right-click a volume and select Provisioning > Delete Volume.
3. A table displays, showing all the volumes for the selected vdisk. In the table, select the volumes to delete. To select up to 100 volumes or clear all selections, toggle the checkbox in the heading row.
4. Click Delete Volume(s).
5. Click Delete to continue; otherwise, click Cancel. If you click Delete, a processing dialog appears. If the task succeeds, an overview panel and a success dialog appear.
6. Click OK. As processing completes, the deleted items are removed from the Configuration View panel.
NOTE: The system might be unable to delete a large number of volumes in a single operation. If you specified to delete a large number of volumes, verify that all were deleted. If some of the specified volumes remain, repeat the deletion on those volumes.
Changing default mapping for multiple volumes (Not supported in Gen 2)
For all volumes in all vdisks or a selected vdisk, you can change the default access to those volumes by all hosts.
When multiple volumes are selected, LUN values are sequentially assigned starting with a LUN value that you specify. For example, if the starting LUN value is 1 for 30 selected volumes, the first volume’s mapping is assigned LUN 1 and so forth, and the last volume’s mapping is assigned LUN 30. For LUN assignment to succeed, ensure that no value in the sequence is already in use. When specifying access through specific ports, the ports and host must be the same type (for example, FC).
CAUTION: Other than as described in the Farad Infrastructure Commissioning Checklist, do not make changes to mapping unless directed to do so by Harris Support. Volume mapping changes take effect immediately. Make changes that limit access to volumes when the volumes are not in use. Before changing a volume’s LUN, be sure to unmount/unpresent/unmap the volume.
52 Provisioning the system
To change default mapping for multiple volumes
1. In the Configuration View panel, right-click Vdisks or a vdisk and then select Provisioning > Map Volume
Defaults.
2. A table displays, showing all the volumes for the selected vdisk. In the table, select the volumes to change. To select up to 100 volumes or clear all selections, toggle the checkbox in the heading row.
3. Select Map.
4. Either:
• Map the volumes to all hosts by setting a starting LUN (required), setting access to read-only or read-write
(the default is no-access), and selecting ports.
• Mask the volumes from all hosts by setting a starting LUN, selecting ports, and setting access to no-access.
Setting the default mapping to no-access will result in the LUN mapping being removed.
5. Click Apply. A message specifies whether the change succeeded or failed.
6. Click OK.
Explicitly mapping multiple volumes
For all volumes in all vdisks or a selected vdisk, you can change access to those volumes by a specific host. When multiple volumes are selected, LUN values are sequentially assigned starting with a LUN value that you specify.
For example, if the starting LUN value is 1 for 30 selected volumes, the first volume’s mapping is assigned LUN
1 and so forth, and the last volume’s mapping is assigned LUN 30. For LUN assignment to succeed, ensure that no value in the sequence is already in use. When specifying access through specific ports, the ports and host must be the same type (for example, FC).
CAUTION: Other than as described in the Farad Infrastructure Commissioning Checklist, do not make changes to mapping unless directed to do so by Harris Support. Volume mapping changes take effect immediately. Make changes that limit access to volumes when the volumes are not in use. Before changing a volume’s LUN, be sure to unmount/unpresent/unmap the volume.
To explicitly map multiple volumes
1. In the Configuration View panel, right-click Vdisks or a vdisk and then select Provisioning > Map Volumes.
2. A table displays, showing all the volumes for the selected vdisk. In the table, select the volumes to change. To select up to 100 volumes or clear all selections, toggle the checkbox in the heading row.
3. In the Maps for Selected Volumes table, select the host to change access for.
4. Select Map.
5. Either:
• Map the volumes to the host by setting a starting LUN, selecting ports, and setting access to read-only or read-write.
• Mask the volumes from the host by setting a starting LUN, selecting ports, and setting access to no-access.
6. Click Apply. A message specifies whether the change succeeded or failed.
7. Click OK.
Changing a volume’s default mapping
CAUTION: Other than as described in the Farad Infrastructure Commissioning Checklist, do not make changes to mapping unless directed to do so by Harris Support. Volume mapping changes take effect immediately. Make changes that limit access to volumes when the volumes are not in use. Be sure to unmount/unpresent/unmap a volume before changing the volume’s LUN.
NEXIO 2300 Series WBI User Guide 53
To view the default mapping
In the Configuration View panel, right-click a volume and select Provisioning > Default Mapping. The main panel shows the volume’s default mapping:
• Ports. Controller host ports through which the volume is mapped to the host.
• LUN. Volume identifier presented to the host.
• Access. Volume access type: read-write, read-only, not-mapped.
To modify the default mapping
1. Select Map.
2. Set the LUN (required) and select the ports and access type. The default is read-write.Setting the default mapping to no-access will result in the LUN mapping being removed.
3. Click Apply. A message specifies whether the change succeeded or failed.
4. Click OK. Each mapping that uses the default settings is updated.
To delete the default mapping
1. Clear Map.
2. Click Apply. A message specifies whether the change succeeded or failed.
3. Click OK. Each mapping that uses the default settings is updated.
Changing a volume’s explicit mappings
CAUTION: Other than as described in the Farad Infrastructure Commissioning Checklist, do not make changes to mapping unless directed to do so by Harris Support. Volume mapping changes take effect immediately. Make changes that limit access to volumes when the volumes are not in use. Be sure to unmount/unpresent/unmap a volume before changing the volume’s LUN.
To view volume mappings
In the Configuration View panel, right-click a volume and select Provisioning > Explicit Mappings. The main panel shows the following information about the volume’s mappings:
• Type. Explicit or Default. Settings for an explicit mapping override the default mapping.
• Host ID. WWPN
• Host Name. User-defined nickname for host.
• Ports. Controller host ports through which the host is mapped to the volume.
• LUN. Volume identifier presented to the host.
• Access. Volume access type: read-write, read-only, no-access (masked), or not-mapped.
To create an explicit mapping
1. In the Maps for Volume table, select a host.
2. Select Map.
3. Set the LUN and select the ports and access type.
4. Click Apply. A message specifies whether the change succeeded or failed.
5. Click OK. The mapping becomes Explicit with the new settings.
To modify an explicit mapping
1. In the Maps for Volume table, select the Explicit mapping to change.
2. Set the LUN and select the ports and access type.
3. Click Apply. A message specifies whether the change succeeded or failed.
4. Click OK. The mapping settings are updated.
54 Provisioning the system
To delete an explicit mapping
1. In the Maps for Volume table, select the Explicit mapping to delete.
2. Clear Map.
3. Click Apply. A message specifies whether the change succeeded or failed.
4. Click OK. The mapping returns to the Default mapping.
Unmapping volumes
You can delete all of the default and explicit mappings for multiple volumes.
CAUTION: Other than as described in the Farad Infrastructure Commissioning Checklist, do not make changes to mapping unless directed to do so by Harris Support. Volume mapping changes take effect immediately. Make changes that limit access to volumes when the volumes are not in use. Before changing a volume’s LUN, be sure to unmount/unpresent/unmap the volume.
To unmap volumes
1. In the Configuration View panel, right-click Vdisks or a vdisk and then select Provisioning > Unmap Volumes.
2. A table displays, showing all the volumes for the selected vdisk. In the table, select the volumes to unmap. To select up to 100 items or clear all selections, toggle the checkbox in the heading row.
3. Click Unmap Volume(s). A message specifies whether the change succeeded or failed.
4. Click OK. Default and explicit mappings are deleted and the volumes’ access type changes to not-mapped.
Expanding a volume (Not supported in Farad Gen 2)
You can expand a volume if its vdisk has free space and sufficient resources. Because volume expansion does not require I/O to be stopped, the volume can continue to be used during expansion.
To expand a volume
1. In the Configuration View panel, right-click a volume and select Tools > Expand Volume.
2. In the main panel, specify the amount of free space to add to the volume.
3. Click Expand Volume. If the specified value exceeds the amount of free space in the vdisk, a dialog lets you expand the volume to the limit of free space in the vdisk. If the task succeeds, the volume’s size is updated in the Configuration View panel.
Adding a host
To add a host
1. Determine the host’s WWN.
2. In the Configuration View panel, right-click the system or Hosts and then select Provisioning > Add Host.
3. In the main panel set the options:
• Host ID (WWN/IQN) (required). Enter the host’s WWN
• Host Name (required). This field is populated with a default name. You may optionally change the default name to one that helps you easily identify the host; for example, FileServer_1. A host name is case sensitive; cannot already exist in the system; cannot include a comma, double quote, or backslash; and can have a maximum of 15 bytes.
4. Click Add Host. If the task succeeds, the new host appears in the Configuration View panel.
Removing hosts
To remove hosts
1. Verify that the hosts you want to remove are not accessing volumes.
2. In the Configuration View panel, either:
NEXIO 2300 Series WBI User Guide 55
• Right-click the system or Hosts and then select Provisioning > Remove Hosts.
• Right-click a host and select Provisioning > Remove Host.
3. In the main panel, select the hosts to remove. To select or clear all items, toggle the checkbox in the heading row.
4. Click Remove Host(s). A confirmation dialog appears.
5. Click Remove to continue; otherwise, click Cancel. If you click Remove, a processing dialog appears. If the task succeeds, an overview panel and a success dialog appear.
6. Click OK. As processing completes, the deleted items are removed from the Configuration View panel.
Changing a host’s name
To change a host’s name
1. In the Configuration View panel, right-click a host and select Provisioning > Rename Host.
2. Enter a new name that helps you easily identify the host; for example, FileServer_1. A host name is case sensitive; cannot already exist in the system; cannot include a comma, double quote, or backslash; and can have a maximum of 15 bytes.
3. Click Modify Name.
Changing host mappings
For each volume that is mapped to the selected host, you can create, modify, and delete explicit mappings. To change a volume’s default mapping, see
Changing a volume’s default mapping on page 53.
CAUTION: Other than as described in the Farad Infrastructure Commissioning Checklist, do not make changes to mapping unless directed to do so by Harris Support. Volume mapping changes take effect immediately. Make changes that limit access to volumes when the volumes are not in use. Be sure to unmount/unpresent/unmap a volume before changing the volume’s LUN.
To view host mappings
In the Configuration View panel, right-click a host and select Provisioning > Manage Host Mappings. The main panel shows the following information about volumes mapped to the host:
• Type. Explicit or Default. Settings for an explicit mapping override the default mapping.
• Name. Volume name.
• Serial Number. Volume serial number.
• Ports. Controller host ports through which the volume is mapped to the host.
• LUN. Volume identifier presented to the host.
• Access. Volume access type: read-write, read-only, no-access (masked), or not-mapped.
To create an explicit mapping
1. In the Maps for Host table, select the Default mapping to override.
2. Select Map.
3. Set the LUN and select the ports and access type.
4. Click Apply. A message specifies whether the change succeeded or failed.
5. Click OK. The mapping becomes Explicit with the new settings.
To modify an explicit mapping
1. In the Maps for Host table, select the Explicit mapping to change.
2. Set the LUN and select the ports and access type.
3. Click Apply. A message specifies whether the change succeeded or failed.
4. Click OK. The mapping settings are updated.
56 Provisioning the system
To delete an explicit mapping
1. In the Maps for Host table, select the Explicit mapping to delete.
2. Clear Map.
3. Click Apply. A message specifies whether the change succeeded or failed.
4. Click OK. The mapping returns to the Default mapping.
Modifying a schedule (Not supported in Farad Gen 2)
To modify a schedule
1. In the Configuration View panel, right-click the system and select Provisioning > Modify Schedule.
2. A table displays in the main panel, showing each schedule and listing Schedule Name, Schedule
Specifications, and Status. In the table, select the schedule to modify.
3. Set the options:
• Start Schedule. Specify a date and a time in the future to be the first instance when the scheduled task will run, and to be the starting point for any specified recurrence.
• Date must use the format yyyy-mm-dd.
• Time must use the format hh:mm followed by either AM, PM, or 24H (24-hour clock). For example,
13:00 24H is the same as 1:00 PM.
• Recurrence. Specify interval at which the task should run. Select either One Time or how often the task should occur. If the task is recurrent, select Minutes, Hours, Days, Weeks, Months, or Years from the list.
The default is One Time. If One Time is selected, no further options are available and the task will occur only on the date and time specified in Start Schedule.
• Time Constraint. Specify a time range within which the task should run. Select either No Time Constraint or times between which the task will run.
If No Time Constraint is selected, the task will run whenever scheduled.
If a set of times are specified, the task can only occur during that period of time. Time must use the format
hh:mm followed by either AM, PM, or 24H (24-hour clock). For example, 13:00 24H is the same as 1:00
PM.
• Date Constraint. Specify days when the task should run. Ensure that this constraint includes the Start
Schedule date. Select No Date Constraint, Any, or a specific time.
If No Date Constraint is selected, the task will occur whenever scheduled.
For Any, select a type of day (any day, weekday, weekend day, or specific day of the week) and a year, month, or specific month. For example, if you select Any Weekday of June, the task can occur only on weekdays in June.
For a specific time, select a type of day (any day, weekday, weekend day, or specific day of the week), a number, and a year, month, or specific month. For example, if you select Sunday number 3 of January, the task can occur only on the 3rd Sunday of January.
• End Schedule. Specify when the task should stop running. Select Continuous, Date, or End After.
If Continuos is selected, the task will never end.
If a date and time is specified, the task will not run as scheduled after that date.
If End After is selected, the task will end after the running the number of times you specify. For example, if you enter 5, the task will run only 5 times.
4. Click Modify Schedule.
5. Click Yes to continue; otherwise, click No. If you click Yes, a processing dialog appears. When processing is complete a success dialog appears.
6. Click OK.
Deleting schedules (Not supported in Farad Gen 2)
If a component has a scheduled task that you no longer want to occur, you can delete the schedule. When a component is deleted, its schedules are also deleted.
To delete task schedules
1. In the Configuration View panel, right-click the system and select Provisioning > Delete Schedule.
NEXIO 2300 Series WBI User Guide 57
2. In the main panel, select the schedule to remove.
3. Click Delete Schedule. A confirmation dialog appears.
4. Click Yes to continue; otherwise, click No. If you click Yes, a processing dialog appears. If the task succeeds, the schedules are removed from the table and from the Configuration View panel. When processing is complete a success dialog appears.
5. Click OK.
58 Provisioning the system
4 Using system tools
Updating firmware
CAUTION:
• If a firmware update is required, specific instructions will be provided via Service Alert or in the Farad
Infrastructure Commissioning Checklist.
• Do not update firmware unless directed by Service Alert or Farad Infrastructure Checklist.
The following material on updating Controller Module, Expansion Module, and Drive Firmware are provided to the reader for general information on the update process.
You can view the current versions of firmware in controller modules, expansion modules, and disks, and install new versions.
TIP: To ensure success of an online update, select a period of low I/O activity. This helps the update complete as quickly as possible and avoids disruptions to host and applications due to timeouts. Attempting to update a storage system that is processing a large, I/O-intensive batch job will likely cause hosts to lose connectivity with the storage system.
IMPORTANT:
• If a vdisk is quarantined, resolve the problem that is causing the vdisk to be quarantined before updating firmware. See information about events 172 and 485 in the Event Descriptions Reference Guide, and
Removing a vdisk from quarantine on page 67.
• If any unwritten cache data is present, firmware update will not proceed. Before you can update firmware, unwritten data must be removed from cache. See information about event 44 in the Event Descriptions
Reference Guide and information about the clear cache command in the CLI Reference Guide.
• If the system’s health is Fault, firmware update will not proceed. Before you can update firmware, you must resolve the problem specified by the Health Reason value on the System Overview panel (
Updating controller-module firmware
CAUTION:
• Do not update firmware unless directed by Service Alert or Farad Infrastructure Checklist.
A controller enclosure can contain one or two controller modules. In a dual-controller system, both controllers should run the same firmware version. You can update the firmware in each controller module by loading a firmware file obtained from the enclosure vendor.
If you have a dual-controller system and the PFU option is enabled, when you update one controller the system automatically updates the partner controller. If PFU is disabled, after updating firmware on one controller you must log into the partner controller’s IP address and perform this firmware update on that controller also.
For best results, the storage system should be in a healthy state before starting firmware update.
NOTE: For information about supported releases for firmware update, see the product’s Release Notes.
NEXIO Farad 2300 Series WBI User Guide 59
To update controller-module firmware
1. Obtain the appropriate firmware file and download it to your computer or network.
2. Restart the MC in the controller to be updated; or if PFU is enabled, restart the MCs in both controllers. For the procedure, see
Restarting or shutting down controllers on page 64.
3. In the Configuration View panel, right-click the system and select Tools > Update Firmware. The table titled
Current Controller Versions shows the currently installed versions.
4. Click Browse and select the firmware file to install.
5. Click Install Controller-Module Firmware File. A dialog box shows firmware-update progress.
The process starts by validating the firmware file:
• If the file is invalid, verify that you specified the correct firmware file. If you did, try downloading it again from the source location.
• If the file is valid, the process continues.
CAUTION: Do not perform a power cycle or controller restart during a firmware update. If the update is interrupted or there is a power failure, the module might become inoperative. If this occurs, contact technical support. The module might need to be returned to the factory for reprogramming.
Firmware update typically takes 10 minutes for a controller with current CPLD firmware, or 20 minutes for a controller with downlevel CPLD firmware. If the controller enclosure has attached enclosures, allow additional time for each expansion module’s EMP to be updated. This typically takes 3 minutes for each EMP in a drive enclosure.
If the SC cannot be updated, the update operation is cancelled. Verify that you specified the correct firmware file and repeat the update. If this problem persists, contact technical support.
When firmware update on the local controller is complete, users are automatically signed out and the controller will restart. Until the restart is complete, the RAIDar Sign In page will say that the system is currently unavailable. When this message is cleared, you may sign in.
If PFU is enabled, allow 10–20 minutes for the partner controller to be updated.
6. Clear your web browser’s cache, then sign in to RAIDar. If PFU is running on the controller you sign in to, a dialog box shows PFU progress and prevents you from performing other tasks until PFU is complete.
NOTE: After firmware update has completed on both controllers, if the system health is Degraded and the health reason indicates that the firmware version is incorrect, verify that you specified the correct firmware file and repeat the update. If this problem persists, contact technical support.
Updating expansion-module firmware
CAUTION:
• Do not update firmware unless directed by Service Alert or Farad Infrastructure Checklist.
A drive enclosure can contain one or two expansion modules. Each expansion module contains an EMP. All modules of the same model should run the same firmware version.
Expansion-module firmware is updated in either of two ways:
• When you update controller-module firmware, all expansion modules are automatically updated to a compatible firmware version.
• You can update the firmware in each expansion module by loading a firmware file obtained from the enclosure vendor.
To update expansion-module firmware
1. Obtain the appropriate firmware file and download it to your computer or network.
60 Using system tools
2. In the Configuration View panel, right-click the system and select Tools > Update Firmware. The table titled
Current Versions of All Expansion Modules (EMPs) shows the currently installed versions.
3. Select the expansion modules to update.
4. Click Browse and select the firmware file to install.
5. Click Install Expansion-Module Firmware File. Messages show firmware-update progress.
CAUTION: Do not perform a power cycle or controller restart during the firmware update. If the update is interrupted or there is a power failure, the module might become inoperative. If this occurs, contact technical support. The module might need to be returned to the factory for reprogramming.
It typically takes 3 minutes to update each EMP in a drive enclosure. Wait for a message that the code load has completed.
6. Verify that each updated expansion module has the correct firmware version.
Updating disk firmware
CAUTION:
• Do not update firmware unless directed by Service Alert or Farad Infrastructure Checklist.
You can update disk firmware by loading a firmware file obtained from your reseller.
A dual-ported disk can be updated from either controller. A single-ported disk that is in a vdisk or is a dedicated spare for a vdisk must be updated from the controller that owns the vdisk. Attempting to update a single-ported disk from the non-owning controller will not cause any change to the disk.
NOTE: Disks of the same model in the storage system must have the same firmware revision.
To update disk firmware
1. Obtain the appropriate firmware file and download it to your computer or network.
2. Check the disk manufacturer’s documentation to determine whether disks must be power cycled after firmware update.
3. Stop I/O to the storage system. During the update all volumes will be temporarily inaccessible to hosts. If I/O is not stopped, mapped hosts will report I/O errors. Volume access is restored after the update completes.
4. In the Configuration View panel, right-click the system and select Tools > Update Firmware. A table titled
Current Versions (Revisions) of All Disk Drives displays the currently installed versions.
5. Select the disks to update.
6. Click Browse and select the firmware file to install.
7. Click Install Disk Firmware File.
CAUTION: Do not power cycle enclosures or restart a controller during the firmware update. If the update is interrupted or there is a power failure, the disk might become inoperative. If this occurs, contact technical support.
It typically takes several minutes for the firmware to load. Wait for a message that the update has completed.
8. If the updated disks must be power cycled: a. Shut down both controllers; see
Restarting or shutting down controllers on page 64.
b. Power cycle all enclosures as described in your product’s Setup Guide.
9. Verify that each disk has the correct firmware revision.
NEXIO Farad 2300 Series WBI User Guide 61
Saving logs
CAUTION:
• Do not gather logs unless directed to do so by Harris Support.
• Gathering logs may result in a temporary interruption to the I/O. For non-mirrored systems (such as Farad 60) plan to gather logs during a period of low activity.
To help service personnel diagnose a system problem, you might be asked to provide system log data. Using
RAIDar, you can save log data to a compressed zip file. The file will contain the following data:
• Device status summary, which includes basic status and configuration data for the system
• Each controller’s event log
• Each controller’s debug log
• Each controller’s boot log, which shows the startup sequence
• Critical error dumps from each controller, if critical errors have occurred
• CAPI traces from each controller
NOTE: The controllers share one memory buffer for gathering log data and for loading firmware. Do not try to perform more than one save-logs operation at a time, or to perform a firmware-update operation while performing a save-logs operation.
To save logs
1. In the Configuration View panel, right-click the system and select Tools > Save Logs.
2. In the main panel: a. Enter your name, email address, and phone number so support personnel will know who provided the log data.
b. Enter comments, describing the problem and specifying the date and time when the problem occurred.
This information helps service personnel when they analyze the log data. Comment text can be 500 bytes long.
3. Click Save Logs.
NOTE: In Microsoft Internet Explorer if the download is blocked by a security bar, select its Download
File option. If the download does not succeed the first time, return to the Save Logs panel and retry the save operation.
Log data is collected, which takes several minutes.
4. When prompted to open or save the file, click Save.
• If you are using Firefox and have a download directory set, the file store.zip is saved there.
• Otherwise, you are prompted to specify the file location and name. The default file name is store.zip.
Change the name to identify the system, controller, and date.
NOTE: Because the file is compressed, you must uncompress it before you can view the files it contains. To examine diagnostic data, first view store_yyyy_mm_dd__hh_mm_ss.logs.
Resetting a host port
Making a configuration or cabling change on a host might cause the storage system to stop accepting I/O requests from that host. For example, this problem can occur after moving host cables from one HBA to another on the host. To fix such a problem you might need to reset controller host ports (channels).
62 Using system tools
For a FC host port configured to use FC-AL topology, a reset issues a LIP. For SAS, resetting a host port issues a
COMINIT/COMRESET
sequence and might reset other ports.
To reset a host port
1. In the Configuration View panel, right-click the system and select Tools > Reset Host Port.
2. Select the port to reset. For example, to reset controller A port 1, select A1.
3. Click Reset Host Port.
Rescanning disk channels
A rescan forces a rediscovery of disks and enclosures in the storage system. If both SCs are online and able to communicate with both expansion modules in each connected enclosure, rescan also reassigns the enclosure IDs of attached enclosures based on controller A’s enclosure cabling order. A manual rescan may be needed after system power-up to display enclosures in the proper order. A manual rescan temporarily pauses all I/O processes, then resumes normal operation. It can take up to two minutes for the enclosure IDs to be corrected.
A manual rescan is not needed after inserting or removing disks; the controllers automatically detect these changes. When disks are inserted they are detected after a short delay, which allows the disks to spin up.
To rescan disk channels
1. Verify that both controllers are operating normally.
2. In the Configuration View panel, right-click the system and select Tools > Rescan Disk Channels.
3. Click Rescan.
Restoring system defaults
If the system is not working properly and you cannot determine why, you can restore its default configuration settings. You then can reconfigure the settings that are necessary to use the system.
To restore defaults, use the CLI’s restore defaults command, as described in the CLI Reference Guide.
Clearing disk metadata (Not supported by Farad Gen 2)
CAUTION:
• Executing the Clear Disk Metadata function will result in a temporary interruption of 10 to 15 seconds to the activity on the stack. The Clear Disk Metadata function is not supported.
• Only use this command when all vdisks are online and leftover disks exist. Improper use of this command may result in data loss.
• Do not use this command when a vdisk is offline and one or more leftover disks exist.
If you are uncertain whether to use this command, contact technical support for further assistance.
Each disk in a vdisk has metadata that identifies the owning vdisk, the other members of the vdisk, and the last time data was written to the vdisk. The following situations cause a disk to become a leftover:
• Vdisk members’ timestamps do not match so the system designates members having an older timestamp as leftovers.
• A disk is not detected during a rescan, then is subsequently detected.
When a disk becomes a leftover, the following changes occur:
• The disk’s health becomes Degraded and its How Used state becomes LEFTOVR.
• The disk is automatically excluded from the vdisk, causing the vdisk’s health to become Degraded or Fault, depending on the RAID level.
• The disk’s fault LED is illuminated amber.
If spares are available, and the health of the vdisk is Degraded, the vdisk will use them to start reconstruction.
When reconstruction is complete, you can clear the leftover disk’s metadata. Clearing the metadata will change
NEXIO Farad 2300 Series WBI User Guide 63
the disk’s health to OK and its How Used state to AVAIL, making the disk available for use in a new vdisk or as a spare.
If spares are not available to begin reconstruction, or reconstruction has not completed, keep the leftover disk so that you’ll have an opportunity to recover its data.
This command clears metadata from leftover disks only. If you specify disks that are not leftovers, the disks are not changed.
To clear metadata from leftover disks
1. In the Configuration View panel, right-click the system and then select Tools > Clear Disk Metadata.
2. In the main panel, select leftover disks to clear metadata from. To select or clear all leftover disks, toggle the checkbox in the heading row.
3. Click Clear Metadata. When processing is complete a success dialog appears.
4. Click OK.
Restarting or shutting down controllers
You can restart the processors in a controller module when RAIDar informs you that you have changed a configuration setting that requires restarting or when the controller is not working properly. Shut down the processors in a controller module before you remove it from an enclosure, or before you power off its enclosure for maintenance, repair, or a move.
A restart can be performed on either the SC processor or the processor. A shut down affects both processors.
Restarting
If you restart an SC, it attempts to shut down with a proper failover sequence, which includes stopping all I/O operations and flushing the write cache to disk, and then the controller restarts. The controller is not restarted so it can provide status information to external interfaces.
If you restart a controller, communication with it is lost until it successfully restarts. If the restart fails, the partner remains active with full ownership of operations and configuration information.
CAUTION: If you restart both controller modules, you and users lose access to the system and its data until the restart is complete.
NOTE: When a SC is restarted, live performance statistics that it recorded will be reset; historical performance statistics are not affected. In a dual-controller system, disk statistics may be reduced but will not be reset to zero, because disk statistics are summed between the two controllers. For more information, see help for commands that show statistics.
To perform a restart
1. In the Configuration View panel, right-click the local system and select Tools > Shut Down or Restart
Controller.
2. In the main panel, set the options:
• Operation. Select Restart.
• Controller Type. Select the type of controller processor to restart: Management or Storage.
• Controller. Select the controller to restart: A, B, or Both.
3. Click Restart now. A confirmation dialog appears.
4. Click Yes to continue; otherwise, click No. If you click Yes, a second confirmation dialog appears.
5. Click Yes to continue; otherwise, click No. If you click Yes, a message describes restart activity.
64 Using system tools
Shutting down
Shutting down the SC in a controller module ensures that a proper failover sequence is used, which includes stopping all I/O operations and writing any data in write cache to disk. If the SC in both controller modules is shut down, hosts cannot access the system’s data. Perform a shut down only if you have been advised to do so by
Harris Technical Support.
CAUTION: You can continue to use the CLI when either or both SCs are shut down, but information shown might be invalid.
To perform a shut down
1. In the Configuration View panel, right-click the local system and select Tools > Shut Down or Restart
Controller.
2. In the main panel, set the options:
• Operation. Select Shut down.
• Controller Type. Select Storage.
• Controller. Select the controller to shut down: A, B, or both.
3. Click Shut down now. A confirmation dialog appears.
4. Click Yes to continue; otherwise, click No. If you click Yes, a second confirmation dialog appears.
5. Click Yes to continue; otherwise, click No. If you click Yes, a message describes shutdown activity.
Testing notifications
You can send test messages to verify that EMAIL, SNMP and/or SysLog Server settings are properly configured for destinations to receive event notifications and managed-logs notifications.
For event notification, the EMAIL, SNMP and/or SysLog Server settings must include a notification level other than “none (disabled).” For managed-logs notification, the managed logs feature must be configured and enabled.
For an overview of the log-management feature, see
About managed logs (Not supported) on page 23.
To test event notification
1. In the Configuration View panel, right-click the local system and select Tools > Test Event Notifications and
Managed Logs.
2. Under the Test Event Notifications heading, click Send Event. If the task succeeds, verify that the test message reached the destinations.
To test managed-logs notification
1. In the Configuration View panel, right-click the local system and select Tools > Test Event Notifications and
Managed Logs.
2. Under the Test Managed Logs Notifications heading, click Send Managed Logs. If the task succeeds, verify that the test message reached the destination.
Expanding a vdisk (Not supported in Farad Gen 2)
You can expand the capacity of a vdisk by adding disks to it, up to the maximum number of disks that the storage system supports. Host I/O to the vdisk can continue while the expansion proceeds. You can then create or expand a volume to use the new free space, which becomes available when the expansion is complete. You can expand only one vdisk at a time. The RAID level determines whether the vdisk can be expanded and the maximum number of disks the vdisk can have. This task cannot be performed on an NRAID or RAID1 vdisk.
Adding single-ported disks to a vdisk that contains dual-ported disks is supported; however, because single-ported disks are not fault-tolerant, a confirmation prompt will appear.
NEXIO Farad 2300 Series WBI User Guide 65
IMPORTANT: Expansion can take hours or days to complete, depending on the vdisk’s RAID level and size, disk speed, utility priority, and other processes running on the storage system. You can stop expansion only by deleting the vdisk.
Before expanding a vdisk
Back up the vdisk’s data so that if you need to stop expansion and delete the vdisk, you can move the data into a new, larger vdisk.
To expand a vdisk
1. In the Configuration View panel, right-click a vdisk and select Tools > Expand Vdisk. Information appears about the selected vdisk and all disks in the system.
• In the Disk Selection Sets table, the number of white slots in the vdisk’s Disks field shows how many disks you can add to the vdisk.
• In the enclosure view or list, only suitable available disks are selectable.
2. Select disks to add.
3. Click Expand Vdisk. A Confirm Operation dialog appears.
4. Click OK. The expansion’s progress is shown in the View > Overview panel.
Verifying a vdisk (Not supported in Farad Gen 2)
If you suspect that a fault-tolerant (mirror or parity) vdisk has a problem, run the Verify utility to check the vdisk’s integrity. For example, if the storage system was operating outside the normal temperature range, verify its vdisks.
The Verify utility analyzes the selected vdisk to find and fix inconsistencies between its redundancy data and its user data. This utility fixes parity mismatches for RAID 3, 5, 6, and 50, and mirror mismatches for RAID 1 and
10. This task can be performed only on a vdisk whose status is FTOL (fault tolerant and online); it cannot be performed for NRAID or RAID0.
TIP: Media Scrub Vdisk (
page 67 ) operates similarly to Verify Vdisk but can find and fix media errors for any
RAID level, including NRAID and RAID0.
Verification can last over an hour, depending on the size of the vdisk, the utility priority, and the amount of I/O activity. You can use a vdisk while it is being verified. When verification is complete, event 21 is logged and specifies the number of inconsistencies found. Such inconsistencies can indicate that a disk in the vdisk is going bad. For information about identifying a failing disk, use the SMART option (see
Configuring SMART on page 38).
If too many utilities are running for verification to start, either wait until those utilities have completed and try again, or abort a utility to free system resources. If you abort verification, you cannot resume it; you must start it over.
To verify a vdisk
1. In the Configuration View panel, right-click a fault-tolerant vdisk and select Tools > Verify Vdisk.
2. Click Start Verify Utility. A message confirms that verification has started.
3. Click OK. The panel shows the verification’s progress.
To abort vdisk verification
1. In the Configuration View panel, right-click a fault-tolerant vdisk and select Tools > Verify Vdisk.
2. Click Abort Verify Utility. A message confirms that verification has been aborted.
3. Click OK.
66 Using system tools
Scrubbing a vdisk (Not supported in Farad Gen 2)
The system-level Vdisk Scrub option (see
Configuring background scrub for vdisks (Not supported in Farad Gen
scrub on a selected vdisk. Scrub analyzes a vdisk to find and fix disk errors. It will fix parity mismatches for RAID
3, 5, 6, and 50; mirror mismatches for RAID 1 and 10; and media errors for all RAID levels.
Scrub can last over an hour, depending on the size of the vdisk, the utility priority, and the amount of I/O activity.
However, a “foreground” scrub performed by Media Scrub Vdisk is typically faster than a background scrub performed by Vdisk Scrub. You can use a vdisk while it is being scrubbed. When a scrub is complete, event 207 is logged and specifies whether errors were found and whether user action is required.
To scrub a vdisk
1. In the Configuration View panel, right-click a vdisk and select Tools > Media Scrub Vdisk.
2. Click Start Media Scrub Utility. A message confirms that the scrub has started.
3. Click OK. The panel shows the scrub’s progress.
To abort a vdisk scrub
1. In the Configuration View panel, right-click a vdisk and select Tools > Media Scrub Vdisk.
NOTE: If the vdisk is being scrubbed but the Abort Media Scrub Utility button is grayed out, a background scrub is in progress. To stop the background scrub, disable the Vdisk Scrub option as described in
Configuring background scrub for vdisks (Not supported in Farad Gen 2) on page 42.
2. Click Abort Media Scrub Utility. A message confirms that the scrub has been aborted.
3. Click OK.
Removing a vdisk from quarantine
CAUTION: If a vdisk is removed from quarantine and does not have enough disks to continue operation, its status will change to OFFL and its data cannot be recovered. To continue operation, a RAID3 or RAID5 vdisk can have only one inaccessible disk; a RAID6 vdisk can have only one or two inaccessible disks; a RAID10 or
RAID50 vdisk can have only one inaccessible disk per sub-vdisk. For example, a 16-disk RAID10 vdisk can remain online (critical) with 8 inaccessible disks if one disk per mirror is inaccessible.
The system will automatically quarantine a vdisk having a fault-tolerant RAID level if one or more of its disks becomes inaccessible, or to prevent invalid (“stale”) data that may exist in the controller from being written to the vdisk. Quarantine will not occur if a known-failed disk becomes inaccessible or if a disk becomes inaccessible after failover or recovery. The system will automatically quarantine an NRAID or RAID0 vdisk to prevent invalid data from being written to the vdisk. If quarantine occurs because of an inaccessible disk, event 172 is logged. If quarantine occurs to prevent writing invalid data, event 485 is logged.
Examples of when quarantine can occur are:
• At system power-up, a vdisk has fewer disks online than at the previous power-up. This may happen because a disk is slow to spin up or because an enclosure is not powered up. The vdisk will be automatically dequarantined if the inaccessible disks come online and the vdisk status becomes FTOL (fault tolerant and online), or if after 60 seconds the vdisk status is QTCR or QTDN.
• During system operation, a vdisk loses redundancy plus one more disk; for example, three disks are inaccessible in a RAID6 vdisk or two disks are inaccessible for other fault-tolerant RAID levels. The vdisk will be automatically dequarantined if after 60 seconds the vdisk status is FTOL, FTDN, or CRIT.
Quarantine isolates the vdisk from host access and prevents the system from changing the vdisk status to OFFL
(offline). The number of inaccessible disks determines the quarantine status; from least to most severe:
• QTDN (quarantined with down disks): The vdisk is degraded or online with at least one inaccessible disk. The vdisk can be accessed and remains fault tolerant. For example, one disk is inaccessible in a RAID6 vdisk.
NEXIO Farad 2300 Series WBI User Guide 67
• QTCR (quarantined critical): The vdisk is critical with at least one inaccessible disk. The vdisk can be accessed. For example, two disks are inaccessible in a RAID6 vdisk or one disk is inaccessible for other fault-tolerant RAID levels.
• QTOF (quarantined offline): The vdisk is fault tolerant with multiple inaccessible disks causing user data to be incomplete, or is an NRAID or RAID0 vdisk.
When a vdisk is quarantined, its disks become write-locked, its volumes become inaccessible, and it is not available to hosts until it is dequarantined. If there are interdependencies between the quarantined vdisk’s volumes and volumes in other vdisks, quarantine may temporarily impact operation of those other volumes. Depending on the operation, the length of the outage, and the settings associated with the operation, the operation may automatically resume when the vdisk is dequarantined or may require manual intervention. A vdisk can remain quarantined indefinitely without risk of data loss.
A vdisk is dequarantined when it is brought back online, which can occur in three ways:
• If the inaccessible disks come online, making the vdisk FTOL, the vdisk is automatically dequarantined.
• If after 60 seconds from being quarantined the vdisk is QTCR or QTDN, the vdisk is automatically dequarantined. The inaccessible disks are marked as failed and the vdisk status changes to CRIT (critical) or
FTDN (fault tolerant with down disks). If the inaccessible disks later come online, they are marked as
LEFTOVR (leftover).
• The dequarantine command is used to manually dequarantine the vdisk. If the inaccessible disks later come online, they are marked as LEFTOVR (leftover). If event 485 was logged, use the dequarantine command only as specified by the event’s recommended-action text to avoid data corruption or loss.
A quarantined vdisk can be fully recovered if the inaccessible disks are restored. Make sure that all disks are properly seated, that no disks have been inadvertently removed, and that no cables have been unplugged.
Sometimes not all disks in the vdisk power up. Check that all enclosures have restarted after a power failure. If these problems are found and then fixed, the vdisk recovers and no data is lost.
If the inaccessible disks cannot be restored (for example, they failed), and the vdisk’s status is FTDN or CRIT, and compatible spares are available, reconstruction will automatically begin.
If a replacement disk (reconstruct target) is inaccessible at power up, the vdisk becomes quarantined; when the disk is found, the vdisk is dequarantined and reconstruction starts. If reconstruction was in process, it continues where it left off.
NOTE: The only tasks allowed for a quarantined vdisk are Dequarantine Vdisk and Delete Vdisk. If you delete a quarantined vdisk and its inaccessible disks later come online, the vdisk will reappear as quarantined or offline and you must delete it again (to clear those disks).
To remove a vdisk from quarantine
1. In the Configuration View panel, right-click a quarantined vdisk and select Tools > Dequarantine Vdisk.
2. Click Dequarantine Vdisk. Depending on the number of disks that remain active in the vdisk, its health might change to Degraded (RAID6 only) and its status changes to FTOL, CRIT, or FTDN. For status descriptions,
see Vdisk properties on page 76.
Resetting or saving historical disk-performance statistics
Resetting historical disk-performance statistics
You can reset (clear) all historical performance statistics for all disks. When you reset historical statistics, an event will be logged and new data samples will continue to be stored every quarter hour.
To reset historical disk performance statistics
1. In the Configuration View panel, right-click the local system and select Tools > Reset or Save Disk
Performance Statistics.
2. In the main panel, under the Reset Disk Performance Statistics heading, click Reset. A confirmation dialog appears.
68 Using system tools
3. Click Yes to continue; otherwise, click No. If you click Yes, a processing dialog appears. When processing is complete a success dialog appears.
4. Click OK.
Saving historical disk-performance statistics
NOTE: Only save historical disk-performance statistics under the advisement of Harris Technical Support.
You can download historical disk-performance statistics for all disks in the storage system. This task downloads the data in CSV format to a file, for import into a spreadsheet or other third-party application.
The number of data samples downloaded is fixed at 100 to limit the size of the data file to be generated and transferred. The default is to retrieve all the available data (up to six months) aggregated into 100 samples. You can specify a different time range by specifying a start and end time. If the specified time range spans more than
100 15-minute samples, the data will be aggregated into 100 samples.
The resulting file will contain a row of CSV property names and a row for each data sample, as shown in the following example. For property descriptions, see the topic about the disk-hist-statistics basetype in the CLI Reference Guide.
"sample-time","durable-id","serial-number","number-of-ios", ...
"2012-01-18 01:00:00","disk_1.1","PLV2W1XE","2467917", ...
"2012-01-18 01:15:00","disk_1.1","PLV2W1XE","2360042", ...
...
To save historical disk-performance statistics
1. In the Configuration View panel, right-click the local system and select Tools > Reset or Save Disk
Performance Statistics.
2. In the main panel, under the Save Disk Performance Statistics heading, specify start and end dates and times to define the range of performance data to retrieve.
3. Click Save.
NOTE: In Microsoft Internet Explorer if the download is blocked by a security bar, select its Download
File option. If the download does not succeed the first time, return to the Reset or Save Disk Performance
Statistics panel and retry the save operation.
4. When prompted to open or save the file, click Save.
• If you are using Firefox and have a download directory set, the file Disk_Performance.csv is saved there.
• Otherwise, you are prompted to specify the file location and name. The default file name is
Disk_Performance.csv
. Change the name to identify the system, controller, and date.
NEXIO Farad 2300 Series WBI User Guide 69
70 Using system tools
5 Viewing system status
Viewing information about the system
In the Configuration View panel, right-click the system and select View > Overview. The System Overview table shows:
• Health.
OK
Degraded
Fault
Unknown
• Component. System, Enclosures, Disks, Vdisks, Volumes, Schedules, Configuration Limits, Versions.
• Count.
• Capacity.
• Storage Space.
The table gives the following information about the individual components:
• The system’s capacity and total storage space
• The health, quantity, capacity, and space usage of enclosures, disks, vdisks, and volumes
• Configuration limits, licensed features, and versions of controller firmware and hardware
For descriptions of storage-space color codes, see About storage-space color codes on page 22.
Select a component to see more information about it.
System properties
When you select the System component, two tables display information about the system.
The System Information table shows:
• Health.
• Health Reason. If the system's health is not OK, its Health Reason specifies that a subcomponent is unhealthy.
In the System Overview table, notice which other components are unhealthy and view their properties as described in the sections below.
• System Name.
• System Contact.
• System Location.
• System Information. Description of system.
• Vendor Name.
• Product ID.
• Product Brand.
• SCSI Vendor ID.
• SCSI Product ID.
• Supported Locales. Languages supported by the system.
The System Redundancy Table shows:
• Controller Redundancy Mode.
• Controller Redundancy Status.
• Controller A Status.
• Controller B Status.
NEXIO Farad 2300 Series WBI User Guide 71
Enclosure properties
When you select the Enclosure component a table displays the following information for each enclosure:
• Health. If an enclosure's health is not OK, select it in the Configuration View panel to view details about it.
• Enclosure ID.
• Enclosure WWN.
• Vendor.
• Model.
• Disk Slots. The quantity of disk slots in the enclosure.
Disk properties
When you select the Disks component a table shows:
• Health. If a disk’s health is not OK, select it in the Configuration View panel to view details about it.
• Enclosure ID.
• Slot. The number of the slot the disk resides in.
• Serial Number.
• Vendor.
• Model.
• Revision.
• Type.
•
• Status. Status values are described in the vdisk properties section of
Viewing information about a vdisk on page 75.
• Size. Total size of the disk.
Vdisk properties
When you select the Vdisks component a table displays the following information for each vdisk:
• Health. If a vdisk’s health is not OK, select it in the Configuration View panel to view details about it.
• Name.
• Size. Total size of vdisk.
• Free. Amount of free space remaining on the vdisk.
• RAID. RAID level.
• Status. Status values are described in the vdisk properties section of
Viewing information about a vdisk on page 75.
•
Volume properties
When you select the Volumes component a table displays the following information for each volume:
• Name.
• Serial Number.
• Size. Total size of the volume.
• Vdisk Name. The name of the vdisk the volume resides on.
Schedules properties (Not supported in Farad Gen 2)
When you select the Schedules component a table displays the following information for each schedule:
• Schedule Name.
72 Viewing system status
• Schedule Specification. The start day and time of the schedule.
• Status. Expired or Active.
• Next Time. The next time the task is scheduled to run,
When you select a schedule, two tables display. The first table shows schedule details and the second table shows task details.
Schedule Details table. Displays schedule name and schedule specifications.
• Schedule Name.
• Schedule Specifications. The start date and time of the schedule.
• Status. Expired or active.
• Next Time. The next time the task is scheduled to run.
Task Details table. Displays specifics about the task.
• Task Name.
• Task Type. Type of task assigned to run.
• Status. Outcome of the task.
• Task State. Specific information about task type.
Configuration limits
When you select the Configuration Limits component a table shows the Maximum Vdisks, Maximum Volumes,
Maximum LUNs, Maximum Disks, and Number of Host Ports the system supports.
Version properties
When you select the Versions component a table shows the versions of firmware and hardware in each controller module.
• Storage Controller CPU Type.
• Bundle Version.
• Build Date.
• Storage Controller Code Version.
• Storage Controller Code Baselevel.
• Memory Controller FPGA Code Version. Memory Controller FPGA Code Version.
• Storage Controller Loader Code Version.
• CAPI Version.
• Management Controller Code Version.
• Management Controller Loader Code Version.
• Expander Controller Code Version.
• CPLD Code Version.
• Hardware Version.
• Host Interface Module Version.
• Host Interface Module Model.
• Backplane Type.
• Host Interface Hardware (Chip) Version.
• Disk Interface Hardware (Chip) Version.
• SC Boot Memory Reference Code.
Viewing the system event log
In the Configuration View panel, right-click the system and select View > Event Log. The System Events panel shows the 100 most recent events that have been logged by either controller. All events are logged, regardless of
NEXIO Farad 2300 Series WBI User Guide 73
event-notification settings. Click the buttons above the table to view all events, or only critical, warning, or informational events.
The event log table shows the following information:
• Severity.
Critical. A failure occurred that may cause a controller to shut down. Correct the problem immediately.
Error. A failure occurred that may affect data integrity or system stability. Correct the problem as soon as possible.
Warning. A problem occurred that may affect system stability but not data integrity. Evaluate the problem and correct it if necessary.
Informational. A configuration or state change occurred, or a problem occurred that the system corrected.
No action is required.
• Time. Date and time when the event occurred, shown as year-month-day hour:minutes:seconds. Time stamps have one-second granularity.
• Event ID. An identifier for the event. The prefix A or B identifies the controller that logged the event.
• Code. An event code that helps you and support personnel diagnose problems. For event-code descriptions and recommended actions, see the Event Descriptions Reference Guide.
• Message. Brief information about the event. Click the message to show or hide additional information and recommended actions.
NOTE: If you are having a problem with the system or a vdisk, check the event log before calling technical support. Event messages might enable you to resolve the problem.
When reviewing events, do the following:
1. For any critical, error, or warning events, click the message to view additional information and recommended actions. This information also appears in the Event Descriptions Reference Guide.
Identify the primary events and any that might be the cause of the primary event. For example, an over-temperature event could cause a disk failure.
2. View the event log and locate other critical/error/warning events in the sequence for the controller that reported the event.
Repeat this step for the other controller if necessary.
3. Review the events that occurred before and after the primary event.
During this review you are looking for any events that might indicate the cause of the critical/error/warning event. You are also looking for events that resulted from the critical/error/warning event, known as secondary events.
4. Review the events following the primary and secondary events.
You are looking for any actions that might have already been taken to resolve the problems reported by the events.
Viewing information about all vdisks
In the Configuration View panel, right-click Vdisks and select View > Overview. For each vdisk, the Vdisk
Overview table displays the following information:
• Health.
OK
Degraded
Fault
Unknown
• Component. Vdisk, disk, volume.
• Count. Number of components.
• Capacity. Total capacity of the component.
74 Viewing system status
• Storage Space. Amount of space on the component. For descriptions of storage-space color codes, see
About storage-space color codes on page 22.
The Vdisks table displays more information about each vdisk.
• Health.
• Name. Vdisk name.
• Size. Total storage space in the vdisk.
• Free. Available space in the vdisk.
• RAID. RAID level of the vdisk and all of its volumes.
• Status.
• CRIT: Critical. The vdisk is online but isn’t fault tolerant because some of its disks are down.
• FTDN: Fault tolerant with down disks. The vdisk is online and fault tolerant, but some of its disks are down.
• FTOL: Fault tolerant and online.
• OFFL: Offline. Either the vdisk is using offline initialization, or its disks are down and data may be lost.
• QTCR: Quarantined critical. The vdisk is offline and quarantined because at least one disk is missing; however, the vdisk could be accessed. For instance, one disk is missing from a mirror or RAID5.
• QTDN: Quarantined with down disks. The vdisk is offline and quarantined because at least one disk is missing; however, the vdisk could be accessed and would be fault tolerant. For instance, one disk is missing from a RAID6.
• QTOF: Quarantined offline. The vdisk is offline and quarantined because multiple disks are missing and user data is incomplete.
• STOP: The vdisk is stopped.
• UNKN: Unknown.
• UP: Up. The vdisk is online and does not have fault-tolerant attributes.
• Disk Type.
• Preferred Owner. Controller that owns the vdisk and its volumes during normal operation.
• Current Owner. Either the preferred owner during normal operation or the partner controller when the preferred owner is offline.
• Disks. Quantity of disks in the vdisk.
• Spares. Quantity of dedicated spares in the vdisk.
Viewing information about a vdisk
In the Configuration View panel, right-click a vdisk and select View > Overview. The Vdisks Overview table shows:
• Health.
OK
Degraded
Fault
Unknown
• Component. Vdisk, disks, volumes.
• Count.
• Capacity.
• Storage space.
For descriptions of storage-space color codes, see About storage-space color codes on page 22.
Select a component to see more information about it. When the Vdisk component is selected, you can view properties or historical performance statistics.
NEXIO Farad 2300 Series WBI User Guide 75
NOTE: Failure of a disk in the vdisk causes the Vdisk and Disks components to have Degraded health. Because tables displayed when the Disks component is selected exclude failed disks, those tables will show fewer disks than the Disk component’s Count value.
Vdisk properties
When you select the Vdisk component and click the Properties tab, the Properties for Vdisk table shows:
• Health.
• Health Reason. If a vdisk’s health is not OK, this entry lists the reasons for the health state. If a vdisk’s health is OK, no information is displayed.
• Health Recommendation. If a vdisk’s health is not OK, this entry lists recommendations for correcting the health. If a vdisk’s health is OK, no information is displayed.
• Name. Vdisk name.
• Size. Total storage space in the vdisk.
• Free. Available space in the vdisk.
• Current Owner. Either the preferred owner during normal operation or the partner controller when the preferred owner is offline.
• Preferred Owner. Controller that owns the vdisk and its volumes during normal operation.
• Serial Number.
• RAID. RAID level of the vdisk and all of its volumes.
• Disks. Quantity of disks in the vdisk.
• Spares. Quantity of dedicated spares in the vdisk.
• Chunk Size. The amount of contiguous data that is written to a vdisk member before moving to the next member of the vdisk.
• Created. Date and time the vdisk was created.
• Minimum Disk Size.
• Status.
• CRIT: Critical. The vdisk is online but isn’t fault tolerant because some of its disks are down.
• FTDN: Fault tolerant with down disks. The vdisk is online and fault tolerant, but some of its disks are down.
• FTOL: Fault tolerant and online.
• OFFL: Offline. Either the vdisk is using offline initialization, or its disks are down and data may be lost.
• QTCR: Quarantined critical. The vdisk is offline and quarantined because at least one disk is missing; however, the vdisk could be accessed. For instance, one disk is missing from a mirror or RAID5.
• QTDN: Quarantined with down disks. The vdisk is offline and quarantined because at least one disk is missing; however, the vdisk could be accessed and would be fault tolerant. For instance, one disk is missing from a RAID6.
• QTOF: Quarantined offline. The vdisk is offline and quarantined because multiple disks are missing and user data is incomplete.
• STOP: The vdisk is stopped.
• UNKN: Unknown.
• UP: Up. The vdisk is online and does not have fault-tolerant attributes.
• Current Job.
• CPYBK: The vdisk is in copyback.
• DRSC: Disks in the vdisk are being scrubbed.
• EXPD: The vdisk is being expanded.
• INIT: The vdisk is being initialized.
• RCON: The vdisk is being reconstructed.
76 Viewing system status
• VRFY: The vdisk is being verified.
• VRSC: The vdisk is being scrubbed.
• Drive Spin Down Vdisk Enable. Enabled or disabled.
A second table displays information about unhealthy components. If all components are healthy, this table displays the text, "There is no data for your selection".
Vdisk performance
When you select the Vdisk component and click the Performance tab, the Performance Statistics panel shows three graphs of historical performance statistics for the vdisk: Data Transferred (B), Data Throughput (B/s), and
Average Response Time (
μs). Data samples are taken every quarter hour and the graphs represent up to 50 samples.
To specify a time range of samples to display, set the start and end values and click Update. The system determines whether the number of samples in the time range exceeds the number of samples that can be displayed (50), requiring aggregation. To determine this, the system divides the number of samples in the specified time range by
50, giving a quotient and a remainder. If the quotient is 1, the 50 newest samples will be displayed. If the quotient exceeds 1, each “quotient” number of newest samples will be aggregated into one sample for display. The remainder is the number of oldest samples that will be excluded from display.
• Example 1: A 1-hour range includes 4 samples. 4 is less than 50 so all 4 samples are displayed.
• Example 2: A 15-hour range includes 60 samples. 60 divided by 50 gives a quotient of 1 and a remainder of
10. Therefore, the newest 50 samples will be displayed and the oldest 10 samples will be excluded.
• Example 3: A 30-hour range includes 120 samples. 120 divided by 50 gives a quotient of 2 and a remainder of
20. Therefore, each two newest samples will be aggregated into one sample for display and the oldest 20 samples will be excluded.
If aggregation is required, the system aggregates samples for each disk in the vdisk (as described in
Disk performance on page 83) and then aggregates the resulting values as follows:
• For a count statistic such as data transferred, the aggregated values are added to produce the value of the aggregated sample.
• For a rate statistic such as data throughput, the aggregated values are added and then are divided by their combined interval (seconds per sample multiplied by the number of samples).
The system will change the time settings to match the times of the oldest and newest samples displayed. The graphs are updated each time you click either the Performance tab or the Update button.
• For the vdisk, the Data Transferred graph shows the amounts of data read and written and the combined total over the sampling time period. The base unit is bytes.
• For the vdisk, the Data Throughput graph shows the rates at which data are read and written and the combined total over the sampling time period. The base unit is bytes per second.
• For each disk in the vdisk, the Average Response Time graph shows the average response times for reads and writes over the sampling time period. The base unit is microseconds. To view the graph’s legend, which identifies the color-coding for each disk, select Show Legend.
TIP: If you specify a time range, it is recommended to specify a range of 12 hours or less.
To view performance data for an individual disk, use the Enclosure Overview panel ( page 81
). To view live
(non-historical) performance statistics for one more vdisks, in the CLI use the show vdisk-statistics command.
Disk properties
When you select the Disks component, a Disk Sets table and enclosure view appear. The Disk Sets table shows:
• Total Space. Total storage space in the vdisk, followed by a color-coded measure of how the space is used.
• Type. For RAID10 or RAID50, the sub-vdisk that the disk is in; for other RAID levels, the disk’s RAID level; or SPARE.
NEXIO Farad 2300 Series WBI User Guide 77
• Disk Type.
• SAS: Dual-port SAS.
• sSAS: Dual-port SAS SSD.
• Disks. Quantity of disks in the vdisk or sub-vdisk.
• Size. Total capacity of the disks in the vdisk or sub-vdisk.
The enclosure view table has two tabs. The Tabular tab shows:
• Health. Shows whether the disk is healthy or has a problem.
OK
Degraded
Fault
N/A
Unknown
If the disk’s health is not OK, view health details in the Enclosure Overview panel (
• Name. System-defined disk name using the format Disk-enclosure-number.disk-slot-number.
• Type. SAS, sSAS, SAS MDL.
• State. Shows how the disk is used:
• If the disk is in a vdisk, its RAID level
• AVAIL: Available
• FAILED: The disk is unusable and must be replaced. Reasons for this status include: excessive media errors; SMART error; disk hardware failure; unsupported disk.
• SPARE: Spare assigned to a vdisk
• GLOBAL SP: Global spare
• LEFTOVR: Leftover
Also shows any job running on the disk:
• DRSC: The disk is being scrubbed
• EXPD: The vdisk is being expanded
• INIT: The vdisk is being initialized
• RCON: The vdisk is being reconstructed
• VRFY: The vdisk is being verified
• VRSC: The vdisk is being scrubbed
• Size. Disk capacity.
• Enclosure. Name of the enclosure containing the disk.
• Serial Number. Disk serial number.
• Status. Up (operational) or Not Present.
The Graphical tab shows the locations of the vdisk’s disks in system enclosures and each disk’s Health and State.
Volume properties
When you select the Volumes component, the Volumes table shows:
• Name. Volume name.
• Serial Number. Volume serial number.
• Size. Volume size.
• Vdisk Name. The name of the vdisk containing the volume.
Viewing information about a volume
In the Configuration View panel, right-click a volume and select View > Overview. The Volume Overview table shows:
• Component. Volume, Maps, Schedules.
78 Viewing system status
• Count.
• Capacity. The capacity of the volume.
• Storage Space. The space usage of the volume.
For descriptions of storage-space color codes, see About storage-space color codes on page 22.
Select a component to see more information about it.
Volume properties
When you select the Volume component, the Properties for Volume table shows:
• Vdisk Name. Name of the vdisk that the volume is in.
• Name. Volume name.
• Size. Volume size.
• Total Size.
• Allocated Size.
• Preferred Owner. Controller that owns the vdisk and its volumes during normal operation.
• Current Owner. Either the preferred owner during normal operation or the partner controller when the preferred owner is offline.
• Serial Number. Volume serial number.
• Cache Write Policy. Write-back or Write-through. See
Using write-back or write-through caching on page 18.
• Cache Optimization. Standard or No-mirror. See
Optimizing read-ahead caching (Not supported in Farad Gen
• Read Ahead Size. See
Optimizing read-ahead caching (Not supported in Farad Gen 2) on page 18.
• Type. Standard (typical) volume.
• Preference.
• Health. OK, Degraded, Fault, or Unknown.
• Health Reason. If Health is not OK, this field shows the reason for the health state.
• Health Recommendation. If Health is not OK, this field shows the recommended actions to take to resolve the health issue.
Mapping properties
When you select the Maps component, the Maps for Volume table shows:
• Type. Explicit or Default. Settings for an explicit mapping override the default mapping.
• Host ID. WWPN
• Host Name. User-defined nickname for host.
• Ports. Controller host ports through which the volume is mapped to the host.
• LUN. Volume identifier presented to the host.
• Access. Volume access type: read-write, read-only, no-access (masked), or not-mapped.
For descriptions of storage-space color codes, see About storage-space color codes on page 22.
Select a component to see more information about it.
Schedules properties (Not supported in Farad Gen 2)
When you select the Schedules component, the Schedules for Volume table shows:
• Schedule Name.
• Schedule Specification. The start day and time of the schedule.
• Status. Expired or Active.
• Next Time. The next time the task is scheduled to run,
When you select a schedule, two tables display. The first table shows schedule details and the second table shows task details.
NEXIO Farad 2300 Series WBI User Guide 79
Schedule Details table. Displays schedule name and schedule specifications.
• Schedule Name.
• Schedule Specifications. The start date and time of the schedule.
• Status. Expired or active.
• Next Time. The next time the task is scheduled to run.
Task Details table. Displays specifics about the task.
• Task Name.
• Task Type. Type of task assigned to run.
• Status. Outcome of the task.
• Task State. Specific information about task type.
• Error message. If the task was unable to run or complete, information about the error is listed.
• Information about the specific type of tasks is displayed in the remainder of the table (for example, Destination
Vdisk).
Viewing information about all hosts
In the Configuration View panel, right-click Hosts and select View > Overview. The Hosts table shows the quantity of hosts configured in the system.
For each host, the Hosts Overview table shows the following details:
• Host ID. WWPN.
• Host Name. User-defined nickname for the host.
• Discovered. If the host was discovered and its entry was automatically created, Yes. If the host entry was manually created, No.
• Mapped. If volumes are mapped to the host, Yes; otherwise, No.
• Host Type.
• If the host was discovered and its entry was automatically created, its host-interface type: FC; SAS.
• If the host entry was manually created: Undefined.
Viewing information about a host
In the Configuration View panel, right-click a host and select View > Overview. The Host Overview table shows:
• Component. Host, Maps.
• Count. The quantity of mappings for the host
Select a component to see more information about it.
Host properties
When you select the Host component, the Properties for Host table shows:
• Host ID. WWPN.
• Host Name. User-defined nickname for the host.
• Discovered. If the host was discovered and its entry was automatically created, Yes. If the host entry was manually created, No.
• Mapped. If volumes are mapped to the host, Yes; otherwise, No.
• Host Type.
• If the host was discovered and its entry was automatically created, its host-interface type: FC; SAS.
• If the host entry was manually created: Undefined.
Mapping properties
When you select the Maps component, the Maps for Host table shows:
80 Viewing system status
• Type. Explicit or Default. Settings for an explicit mapping override the default mapping.
• Name. Volume name.
• Serial Number. Volume serial number.
• Ports. Controller host ports through which the volume is mapped to the host.
• LUN. Volume identifier presented to the host.
• Access. Volume access type: read-write, read-only, no-access (masked), or not-mapped.
Viewing information about an enclosure
In the Configuration View panel, right-click an enclosure and select View > Overview. You can view information about the enclosure and its components in a front or rear graphical view, or in a front or rear tabular view.
• Front Graphical. Shows a graphical view of the front of each enclosure and its disks.
• Front Tabular. Shows a tabular view of each enclosure and its disks.
• Rear Graphical. Shows a graphical view of components at the rear of the enclosure.
• Rear Tabular. Shows a tabular view of components at the rear of the enclosure.
In any of these views, select a component to see more information about it. Components vary by enclosure model.
If any components are unhealthy, a table at the bottom of the panel identifies them. When a disk is selected, you can view properties or historical performance statistics.
Enclosure properties
When you select an enclosure, a table shows:
• Health.
OK
Degraded
Fault
Unknown
• Health Reason. If Health is not OK, this field shows the reason for the health state.
• Health Recommendation. If Health is not OK, this field shows recommended actions to take to resolve the health issue.
• Status.
• Enclosure ID.
• Vendor.
• Model.
• Disk Slots.
• Enclosure WWN.
• Midplane Serial Number.
• Part Number.
• Manufacturing Date.
• Manufacturing Location.
• Revision.
• EMP A Revision. Firmware revision of the EMP in controller module A’s EC.
• EMP B Revision. Firmware revision of the EMP in controller module B’s EC.
• EMP A Bus ID.
• EMP B Bus ID.
• EMP A Target ID.
• EMP B Target ID.
• Midplane Type.
• Enclosure Power (watts).
NEXIO Farad 2300 Series WBI User Guide 81
• PCIe 2-Capable. Shows whether the enclosure is capable of using PCI Express version 2.
Disk properties
When you select a disk and click the Properties tab, a table shows:
• Health.
OK. The disk is operating normally.
Degraded
Fault
N/A
Unknown
• Health Reason. If Health is not OK, this field shows the reason for the health state.
• Health Recommendation. If Health is not OK, this field shows recommended actions to take to resolve the health issue.
• Status.
• Up: The disk is present and is properly communicating with the expander.
• Spun Down: The disk is present and has been spun down by the DSD feature.
• Warning: The disk is present but the system is having communication problems with the disk LED processor. For disk and midplane types where this processor also controls power to the disk, power-on failure will result in Error status.
• Error: The disk is present but is not detected by the expander.
• Unknown: Initial status when the disk is first detected or powered on.
• Not Present: The disk slot indicates that no disk is present.
• Enclosure ID.
• Slot.
• How Used.
• AVAIL: Available.
• FAILED: The disk is unusable and must be replaced. Reasons for this status include: excessive media errors; SMART error; disk hardware failure; unsupported disk.
• GLOBAL SP: Global spare.
• LEFTOVR: Leftover.
• VDISK: Used in a vdisk.
• VDISK SP: Spare assigned to a vdisk.
Any jobs running on the disk or its vdisk follow the How Used value:
• CPYBK: The vdisk is in copyback.
• DRSC: The disk is being scrubbed
• EXPD: The vdisk is being expanded
• INIT: The vdisk is being initialized
• RCON: The vdisk is being reconstructed
• VRFY: The vdisk is being verified
• VRSC: The vdisk is being scrubbed
• Type.
• SAS: Dual-port SAS.
• sSAS: Dual-port SAS SSD.
• SAS MDL.
• Vendor.
• Model.
• Size.
• RPM. x1000.
82 Viewing system status
• Transfer Rate. The data transfer rate in Gbit/s.
Some 6 Gbit/s disks might not consistently support a 6 Gbit/s transfer rate. If this happens, the controller automatically adjusts transfers to those disks to 3 Gbit/s, increasing reliability and reducing error messages with little impact on system performance. This rate adjustment persists until the controller is restarted or power-cycled.
• Revision. Disk firmware revision number.
• Serial Number.
• Current Job.
• DRSC: Disks in the vdisk are being scrubbed.
• EXPD: The vdisk is being expanded.
• INIT: The vdisk is being initialized.
• RCON: The vdisk is being reconstructed.
• VRFY: The vdisk is being verified.
• VRSC: The vdisk is being scrubbed.
•
SMART. Shows whether SMART is enabled. For more information, see Configuring SMART on page 38.
• Current Owner. For the disk’s vdisk, either the preferred owner during normal operation or the partner controller when the preferred owner is offline.
• Drive Spin Down Count. How many times the disk has been spun down.
Disk performance
When you select a disk and click the Performance tab, a table shows eight graphs of historical performance statistics for the disk. Data samples are taken every quarter hour and the graphs represent up to 50 samples. By default, the graphs show the newest 50 samples.
To specify a time range of samples to display, set the start and end values and click Update. The system determines whether the number of samples in the time range exceeds the number of samples that can be displayed (50), requiring aggregation. To determine this, the system divides the number of samples in the specified time range by
50, giving a quotient and a remainder. If the quotient is 1, the 50 newest samples will be displayed. If the quotient exceeds 1, each “quotient” number of newest samples will be aggregated into one sample for display. The remainder is the number of oldest samples that will be excluded from display.
• Example 1: A 1-hour range includes 4 samples. 4 is less than 50 so all 4 samples are displayed.
• Example 2: A 15-hour range includes 60 samples. 60 divided by 50 gives a quotient of 1 and a remainder of
10. Therefore, the newest 50 samples will be displayed and the oldest 10 samples will be excluded.
• Example 3: A 30-hour range includes 120 samples. 120 divided by 50 gives a quotient of 2 and a remainder of
20. Therefore, each two newest samples will be aggregated into one sample for display and the oldest 20 samples will be excluded.
If aggregation is required, the system calculates values for the aggregated samples. For a count statistic (total data transferred, data read, data written, total I/Os, number of reads, number of writes), the samples’ values are added to produce the value of the aggregated sample. For a rate statistic (total data throughput, read throughput, write throughput, total IOPS, read IOPS, write IOPS), the samples’ values are added and then are divided by their combined interval. The base unit for data throughput is bytes per second.
• Example 1: Two samples’ number-of-reads values must be aggregated into one sample. If the value for sample
1 is 1060 and the value for sample 2 is 2000 then the value of the aggregated sample is 3060.
• Example 2: Continuing from example 1, each sample’s interval is 900 seconds so their combined interval is
1800 seconds. Their aggregate read-IOPs value is their aggregate number of reads (3060) divided by their combined interval (1800 seconds), which is 1.7.
The system will change the time settings to match the times of the oldest and newest samples displayed. The graphs are updated each time you click either the Performance tab or the Update button.
• Data Transferred (GB). Shows the amounts of data read and written and the combined total over the sampling time period. The base unit is bytes.
• Data Throughput (MB/s). Shows the rates at which data are read and written and the combined total over the sampling time period. The base unit is bytes per second.
NEXIO Farad 2300 Series WBI User Guide 83
• I/O (K). Shows the numbers of reads and writes and the combined total over the sampling time period.
• IOPS. Shows numbers of reads and writes per second and the combined total over the sampling time period.
• Average Response Time (
μs). Shows the average response times for reads and writes and the combined overage over the sampling time period. The base unit is microseconds.
• Average I/O Size (KB). Shows the average sizes of reads and writes and the combined average over the sampling time period. The base unit is bytes.
• Disk Error Counters. Shows the number of disk errors over the sampling time period.
• Average Queue Depth. Shows the average number of pending I/O operations that are being serviced over the sampling time period. This value represents periods of activity only and excludes periods of inactivity.
TIP: If you specify a time range, it is recommended to specify a range of 12 hours or less.
To view summary performance data for a vdisk, use the Vdisk Overview panel as described on page 75
. To view live (non-historical) performance statistics for one more disks, in the CLI use the show disk-statistics command.
Power supply properties
When you select a power supply, a table shows:
• Health.
OK
Degraded
Fault
Unknown
• Health Reason. If Health is not OK, this field shows the reason for the health state.
• Health Recommendation. If Health is not OK, this field shows recommended actions to take to resolve the health issue.
• Status.
• Model.
• Vendor.
• Location.
• Serial Number.
• Revision.
• Part Number.
• Manufacturing Date.
• Manufacturing Location.
Controller module properties
When you select a controller module, a table shows:
• Health.
OK
Fault
Unknown
• Health Reason. If Health is not OK, this field shows the reason for the health state.
• Health Recommendation. If Health is not OK, this field shows recommended actions to take to resolve the health issue.
• Status.
• Controller ID.
• Description.
84 Viewing system status
• CPLD Version.
• Storage Controller Code Version.
• Model.
• Storage Controller CPU Type.
• Serial Number.
• Part Number.
• Position.
• Hardware Version.
• Revision.
• Manufacturing Date.
• Manufacturing Location.
Controller module: network port properties
When you select a network port, a table shows:
• Health.
OK. The port is operating normally.
Degraded. The port’s operation is degraded.
• Health Reason. If Health is not OK, this field shows the reason for the health state.
• MAC Address.
• Addressing Mode.
• IP Address.
• Gateway.
• Subnet Mask.
Controller module: host port properties
When you select a host port, a table shows:
• Health.
OK
Degraded
Fault
N/A
• Health Reason. If Health is not OK, this field shows the reason for the health state.
• Status.
• Ports.
• Media.
• Target ID.
• Configured Speed.
• Actual Speed.
Controller module: expansion port properties
When you select an expansion (Out) port, a table shows:
• Health.
OK
Degraded
Fault
N/A
Unknown
NEXIO Farad 2300 Series WBI User Guide 85
• Health Reason. If Health is not OK, this field shows the reason for the health state.
• Health Recommendation. If Health is not OK, this field shows recommended actions to take to resolve the health issue.
• Status.
• Name.
Controller module: CompactFlash properties
When you select a CompactFlash card in the Rear Tabular view, a table shows:
• Health.
OK
Fault
• Health Reason. If Health is not OK, this field shows the reason for the health state.
• Health Recommendation. If Health is not OK, this field shows recommended actions to take to resolve the health issue.
• Status.
• Cache Flush.
• Enabled: If the controller loses power, it will automatically write cache data to the CompactFlash card.
Cache flush is normally enabled, but is temporarily disabled during controller shut down.
• Disabled: Cache flush is disabled.
Drive enclosure: I/O module properties
When you select an I/O module, a table shows:
• Health.
OK
Degraded
Fault
Unknown
• Health Reason. If Health is not OK, this field shows the reason for the health state.
• Status.
• Controller ID.
I/O modules: In port properties
When you select an In port, a table shows:
• Health.
OK
Degraded
Fault
N/A
Unknown
• Health Reason. If Health is not OK, this field shows the reason for the health state.
• Health Recommendation. If Health is not OK, this field shows recommended actions to take to resolve the health issue.
• Status.
• Name.
86 Viewing system status
I/O modules: Out port properties
When you select an Out port, a table shows:
• Health.
OK
Degraded
Fault
N/A
Unknown
• Health Reason. If Health is not OK, this field shows the reason for the health state.
• Health Recommendation. If Health is not OK, this field shows recommended actions to take to resolve the health issue.
• Status.
• Name.
NEXIO Farad 2300 Series WBI User Guide 87
88 Viewing system status
A SNMP reference
This appendix describes the SNMP capabilities that 4000 Series storage systems support. This includes standard
MIB-II, the FA SNMP MIB version 2.2 objects, and enterprise traps.
4000 Series storage systems can report their status through SNMP. SNMP provides basic discovery using MIB-II, more detailed status with the FA MIB 2.2, and asynchronous notification using enterprise traps.
SNMP is a widely used network monitoring and control protocol. It is an application layer protocol that facilitates the exchange of management information between network devices. It is part of the TCP/IP protocol suite.
SNMP enables network administrators to manage network performance, find and solve network problems, and plan for network growth. Data is passed from SNMP agents reporting activity on each network device to the workstation console used to oversee the network. The agents return information contained in a MIB, which is a data structure that defines what is obtainable from the device and what can be controlled (turned on and off, etc.).
Supported SNMP versions
4000 Series storage systems allow use of SNMPv2c or SNMPv3. SNMPv2c uses a community-based security scheme. For improved security, SNMPv3 provides authentication of the network management system that is accessing the storage system, and encryption of the information transferred between the storage system and the network management system.
When SNMPv3 is disabled, SNMPv2c will be active. When SNMPv3 is enabled, SNMPv2c will only have access to the MIB-II common system information; this allows device discovery.
Whether you use SNMPv2c or v3, note that the only SNMP-writable information is the system contact, name, and location. System data, configuration, and state cannot be changed via SNMP.
Standard MIB-II behavior
MIB-II is implemented to support basic discovery and status.
An SNMP OID is a number assigned to devices in a network for ID purposes. OID numbering is hierarchical.
Using the IETF notation of digits and dots resembling very long IP addresses, various registries such as ANSI assign high-level numbers to vendors and organizations. They, in turn, append digits to the number to identify individual devices or software processes.
The system OID (sysObjectID) is based on the vendor name followed by “.2.” and the identifier for the particular product model. For example, the OID for 4000 Series storage systems is 1.3.6.1.4.1.11.2.347. System uptime is an offset from the first time this object is read.
In the system group, all objects can be read. The contact, name, and location objects can be set.
In the interfaces group, an internal PPP interface is documented, but it is not reachable from external to the device.
The address translation (at) and external gateway protocol (egp) groups are not supported.
Enterprise traps
Traps can be generated in response to events occurring in the storage system. These events can be selected by severity and by individual event type. A maximum of three SNMP trap destinations can be configured by IP address.
Enterprise event severities are informational, minor, major, and critical. There is a different trap type for each of these severities. The trap format is represented by the enterprise traps MIB, dhtraps.mib. Information included is the event ID, the event code type, and a text description generated from the internal event. Equivalent information can also be sent using email or popup alerts to users who are logged in to RAIDar.
The text of the trap MIB is included at the end of this appendix.
NEXIO Farad 2300 Series WBI User Guide 89
FA MIB 2.2 SNMP behavior
The FA MIB 2.2 objects are in compliance with the FA MIB v2.2 Specification (FA MIB2.2 Spec). For a full description of this MIB, go to: www.emc.com/microsites/fibrealliance .
FA MIB 2.2 was never formally adopted as a standard, but it is widely implemented and contains many elements useful for storage products. This MIB generally does not reference and integrate with other standard SNMP information; it is implemented under the experimental subtree.
Significant status within the device includes such elements as its temperature and power sensors, the health of its storage elements such as vdisks, and the failure of any fault-tolerant component including an I/O controller. While sensors can be individually queried, for the benefit of network management systems all the above elements are combined into an “overall status” sensor. This is available as the unit status (connUnitStatus for the only unit), and a “sensor” in the sensor table.
The revisions of the various components within the device can be requested through SNMP.
The port section is only relevant to products with FC host ports.
The event table allows 400 recently-generated events to be requested. Informational, minor, major, or critical event types can be selected; whichever type is selected enables the capture of that type and more severe events.
This mechanism is independent of the assignment of events to be generated into traps.
The traps section is not supported. It has been replaced by an ability to configure trap destinations using the CLI or
RAIDar. The statistics section is not implemented.
The following table lists the MIB objects, their descriptions and the value set in a 4000 Series storage system.
Unless specified otherwise, objects are not settable.
Table 12 FA MIB 2.2 objects, descriptions, and values
Object
RevisionNumber
UNumber
SystemURL
StatusChangeTime
ConfigurationChangeTime
ConnUnitTableChangeTime
Description Value
Revision number for this MIB
Number of connectivity units present
0220
1
Top-level URL of the device; for example, http://10.1.2.3. If a web server is not present on the device, this string is empty in accordance with the FA MIB2.2 Spec.
Default: http://10.0.0.1 sysuptime
timestamp of the last status change event, in centiseconds. sysuptime
starts at 0 when the SC boots and keeps track of the up time. statusChangeTime
is updated each time an event occurs.
0 at startup
0 at startup sysuptime timestamp of the last configuration change event, in centiseconds. sysuptime starts at 0 when the SC boots and keeps track of the up time. configurationChangeTime
is updated each time an event occurs.
sysuptime timestamp of the last update to the connUnitTable (an entry was either added or deleted), in centiseconds
0 always (entries are not added to or deleted from the connUnitTable)
90 SNMP reference
Table 12 FA MIB 2.2 objects, descriptions, and values (continued)
Object connUnitTable connUnitId connUnitGlobalId connUnitType connUnitNumports connUnitState connUnitStatus connUnitProduct connUnitSn connUnitUpTime connUnitUrl connUnitDomainId connUnitPrincipal connUnitNumSensors connUnitStatusChangeTime connUnitConfiguration
ChangeTime connUnitNumRevs connUnitNumZones connUnitModuleId connUnitName connUnitInfo connUnitControl connUnitContact connUnitLocation
Description Value
Includes the following objects as specified by the FA MIB2.2 Spec
Unique ID for this connectivity unit Total of 16 bytes comprised of 8 bytes of the node WWN or similar serial number-based identifier (for example,
1000005013b05211) with the trailing 8 bytes equal to zero
Same as connUnitId Same
Type of connectivity unit
Number of host ports in the connectivity unit storage-subsystem(11)
Number of host ports
Overall state of the connectivity unit
Connectivity unit vendor’s product model name online(2) or unknown(1), as appropriate
Overall status of the connectivity unit ok(3), warning(4), failed(5), or unknown(1), as appropriate
Model string
Serial number for this connectivity unit Serial number string
Number of centiseconds since the last unit initialization
0 at startup
Same as systemURL
Not used; set to all 1s as specified by the FA MIB2.2 Spec
Same as systemURL
0xFFFF
Whether this connectivity unit is the principal unit within the group of fabric elements. If this value is not applicable, returns unknown.
unknown(1)
Number of sensors in the connUnitSensorTable
33
Same as statusChangeTime Same
Same as configurationChangeTime
Number of revisions in the connUnitRevsTable
Not supported
Not supported
Same as configurationChangeTime
16
0
16 bytes of 0s
Settable: Display string containing a name for this connectivity unit
Default: Uninitialized Name
Settable: Display string containing information about this connectivity unit
Default: Uninitialized Info
Not supported invalid(2) for an SNMP GET operation and not settable through an SNMP SET operation.
Default: Uninitialized Contact Settable: Contact information for this connectivity unit
Settable: Location information for this connectivity unit
Default: Uninitialized Location
NEXIO Farad 2300 Series WBI User Guide 91
Table 12 FA MIB 2.2 objects, descriptions, and values (continued)
Object connUnitEventFilter connUnitNumEvents connUnitMaxEvents connUnitEventCurrID connUnitRevsTable connUnitRevsUnitId connUnitRevsIndex connUnitRevsRevId connUnitRevsDescription connUnitSensorTable connUnitSensorUnitId connUnitSensorIndex connUnitSensorName connUnitSensorStatus connUnitSensorInfo connUnitSensorMessage connUnitSensorType connUnitSensor
Characteristic connUnitPortTable connUnitPortUnitId
Description Value
Defines the event severity that will be logged by this connectivity unit.
Settable only through RAIDar.
Number of events currently in the connUnitEventTable
Default: info(8)
Varies as the size of the Event Table varies
Maximum number of events that can be defined in the connUnitEventTable
400
Not supported 0
Includes the following objects as specified by the FA MIB2.2 Spec connUnitId
of the connectivity unit that contains this revision table
Same as connUnitId
Unique value for each connUnitRevsEntry
between 1 and connUnitNumRevs
Vendor-specific string identifying a revision of a component of the connUnit
Description of a component to which the revision corresponds
See
External details for connUnitRevsTable on page 95
String specifying the code version.
Reports “Not Installed or Offline” if module information is not available.
See
External details for connUnitRevsTable on page 95
Includes the following objects as specified by the FA MIB2.2 Spec connUnitId
of the connectivity unit that contains this sensor table
Same as connUnitId
Unique value for each connUnitSensorEntry
between 1 and connUnitNumSensors
See
External details for connUnitSensorTable on page 96
Textual ID of the sensor intended primarily for operator use
See
External details for connUnitSensorTable on page 96
Status indicated by the sensor ok(3), warning(4), or failed(5) as appropriate for FRUs that are present, or other(2) if FRU is not present.
Empty string Not supported
Description the sensor status as a message connUnitSensorName
followed by the appropriate sensor reading.
Temperatures display in both Celsius and Fahrenheit; for example, CPU
Temperature (Controller Module A):
48C 118F). Reports “Not installed” or
“Offline” if data is not available.
Type of component being monitored by this sensor
See
External details for connUnitSensorTable on page 96
Characteristics being monitored by this sensor
See
External details for connUnitSensorTable on page 96
Includes the following objects as specified by the FA MIB2.2 Spec connUnitId
of the connectivity unit that contains this port
Same as connUnitId
92 SNMP reference
Table 12 FA MIB 2.2 objects, descriptions, and values (continued)
Object connUnitPortIndex connUnitPortType connUnitPortFCClassCap connUnitPortFCClassOp connUnitPortState connUnitPortStatus
Description Value
Unique value for each connUnitPortEntry
between 1 and connUnitNumPorts
Port type
Unique value for each port, between 1 and the number of ports
Overall protocol status for the port
Technology of the port transceiver not-present(3), or n-port(5) for point-to-point topology, or l-port(6)
FC ports return 8 for class-three Bit mask that specifies the classes of service capability of this port. If this is not applicable, returns all bits set to zero.
Bit mask that specifies the classes of service that are currently operational. If this is not applicable, returns all bits set to zero.
FC ports return 8 for class-three
State of the port hardware unknown(1), online(2), offline(3), bypassed(4) unknown(1), unused(2), ok(3), warning(4), failure(5), notparticipating(6), initializing(7), bypass(8) unknown(1) for FC ports connUnitPortTransmitter
Type connUnitPortModuleType connUnitPortWwn connUnitPortFCId connUnitPortSn connUnitPortRevision connUnitPortVendor connUnitPortSpeed connUnitPortControl connUnitPortName connUnitPortPhysical
Number connUnitPortStatObject connUnitEventTable connUnitEventUnitId
Module type of the port connector
FC WWN of the port if applicable unknown(1)
WWN octet for the port, or empty string if the port is not present
Assigned FC ID of this port FC ID of the port
All bits set to 1 if the FC ID is not assigned or if the port is not present
Serial number of the unit (for example, for a GBIC). If this is not applicable, returns an empty string.
Empty string
Port revision (for example, for a GBIC) Empty string
Port vendor (for example, for a GBIC) Empty string
Speed of the port in KB/s (1 KByte =
1000 Byte)
Not supported
Port speed in KB/s, or 0 if the port is not present invalid(2) for an SNMP GET operation and not settable through an SNMP SET operation
String describing the addressed port
See
External details for connUnitPortTable on page 97
Port number represented on the hardware
Port number represented on the hardware
Not supported 0 (No statistics available)
Includes the following objects as specified by the FA MIB2.2 Spec connUnitId
of the connectivity unit that contains this port
Same as connUnitId
NEXIO Farad 2300 Series WBI User Guide 93
Table 12 FA MIB 2.2 objects, descriptions, and values (continued)
Object connUnitEventIndex connUnitEventId connUnitREventTime connUnitSEventTime connUnitEventSeverity connUnitEventType connUnitEventObject connUnitEventDescr
Description Value
Index into the connectivity unit’s event buffer, incremented for each event
Starts at 1 every time there is a table reset or the unit’s event table reaches its maximum index value
Internal event ID, incremented for each event, ranging between 0 and connUnitMaxEvents
Starts at 0 every time there is a table reset or connUnitMaxEvents is reached
Real time when the event occurred, in the following format:
DDMMYYYY HHMMSS sysuptime
timestamp when the event occurred
0 for logged events that occurred prior to or at startup
0 at startup
Event severity level
Type of this event
Not used
Text description of this event
Not supported
Not supported error(5), warning(6) or info(8)
As defined in CAPI
0
Formatted event, including relevant parameters or values
N/A
N/A connUnitLinkTable connUnitPortStatFabric
Table connUnitPortStatSCSITable connUnitPortStatLANTable
SNMP TRAPS trapMaxClients trapClientCount connUnitEventTrap trapRegTable trapRegIpAddress trapRegPort trapRegFilter trapRegRowState
Enterprise-specific fields
Not supported
Not supported
The following SNMP traps are supported
Maximum number of trap clients 1
N/A
N/A
1 if traps enabled; 0 if traps not enabled Number of trap clients currently enabled
This trap is generated each time an event occurs that passes the connUnitEventFilter
and the trapRegFilter
N/A
Includes the following objects per the
FA MIB2.2 Spec
IP address of a client registered for traps
IP address set through Telnet
User Datagram Protocol (UDP) port to send traps to for this host
162
Settable: Defines the trap severity filter for this trap host. The connUnit will send traps to this host that have a severity level less than or equal to this value.
Default: warning(6)
Specifies the state of the row READ: rowActive(3) if traps are enabled through Telnet; otherwise rowInactive(2)
WRITE: Not supported
Includes the following objects
94 SNMP reference
Table 12 FA MIB 2.2 objects, descriptions, and values (continued)
Object cpqSiSysSerialNum cpqSiSysProductId cpqSiProductName cpqHoMibStatusArray cpqHoGUID
Description Value
System serial number
System product ID
For example, 3CL8Y40991
For example, 481321-001
System product name
An array of MIB status structures.
Octets 0–3 in block 0 are reserved for systems management and serve as an aggregate of the other MIBs.
For example, DH4000
Octet 0: 0.
Octet 1 (overall status):
0 = Not available;
1 = Unknown/other;
2 = OK/normal;
3 = Degraded/warning;
4 = Failed/critical
Octet 2 (system flags):
9 = device is not a server and web-based management is enabled
Octet 3 (device type):
14 = enclosure
For example, 00.02.09.14 (hex)
Globally unique identifier formed from the product ID and serial number
For example, 4813213CL8Y40991
External details for certain FA MIB 2.2 objects
Tables in this section specify values for certain objects described in Table 12
.
External details for connUnitRevsTable
Table 13 connUnitRevsTable index and description values connUnitRevsIndex connUnitRevsDescription
13
14
15
16
17
9
10
11
12
7
8
5
6
3
4
1
2
SC processor Type (I/O Manager-A)
Bundle Version (I/O Manager-A)
Build Date (I/O Manager-A)
SC Code Version (I/O Manager-A)
SC Code Baselevel (I/O Manager-A)
Memory Controller FPGA Code Version (I/O Manager-A)
SC Loader Code Version (I/O Manager-A)
CAPI Version (I/O Manager-A)
MC Code Version (I/O Manager-A)
MC Loader Code Version (I/O Manager-A)
EC Code Version (I/O Manager-A)
CPLD Code Version (I/O Manager-A)
Hardware Version (I/O Manager-A)
Host Interface Module Version (I/O Manager-A)
Host Interface Module Model (I/O Manager-A)
Backplane Type (I/O Manager-A)
Host Interface Hardware (Chip) Version (I/O Manager-A)
NEXIO Farad 2300 Series WBI User Guide 95
Table 13 connUnitRevsTable index and description values (continued) connUnitRevsIndex connUnitRevsDescription
30
31
32
33
26
27
28
29
34
35
36
22
23
24
25
18
19
20
21
Disk Interface Hardware (Chip) Version (I/O Manager-A)
SC processor Type (I/O Manager-A)
Bundle Version (I/O Manager-B)
Build Date (I/O Manager-B)
SC Code Version (I/O Manager-B)
SC Code Baselevel (I/O Manager-B)
Memory Controller FPGA Code Version (I/O Manager-B)
SC Loader Code Version (I/O Manager-B)
CAPI Version (I/O Manager-B)
MC Code Version (I/O Manager-B)
MC Loader Code Version (I/O Manager-B)
EC Code Version (I/O Manager-B)
CPLD Code Version (I/O Manager-B)
Hardware Version (I/O Manager-B)
Host Interface Module Version (I/O Manager-B)
Host Interface Module Model (I/O Manager-B)
Backplane Type (I/O Manager-B)
Host Interface Hardware (Chip) Version (I/O Manager-B)
Disk Interface Hardware (Chip) Version (I/O Manager-B)
External details for connUnitSensorTable
Table 14 connUnitSensorTable index, name, type, and characteristic values connUnitSensorIndex connUnitSensorName
7
8
5
6
3
4
1
2
9
10
11
12
13
On-Board Temperature 1 Controller A
On-Board Temperature 1 Controller B
On-Board Temperature 2 Controller A
On-Board Temperature 2 Controller B
On-Board Temperature 3 Controller A
On-Board Temperature 3 Controller B
Disk Controller Temp Controller A
Disk Controller Temp Controller B
Memory Controller Temp Controller A
Memory Controller Temp Controller B
Capacitor Pack Voltage Controller A
Capacitor Pack Voltage Controller B
Capacitor Cell 1 Voltage Controller A connUnitSensorType connUnitSensor
Characteristic board(8) board(8) board(8) board(8) board(8) board(8) board(8) board(8) board(8) board(8) board(8) board(8) board(8) temperature temperature temperature temperature temperature temperature temperature temperature temperature temperature power power power
96 SNMP reference
Table 14 connUnitSensorTable index, name, type, and characteristic values (continued) connUnitSensorIndex connUnitSensorName
38
39
40
41
42
43
34
35
36
37
30
31
32
33
26
27
28
29
22
23
24
25
18
19
20
21
14
15
16
17
Capacitor Cell 1 Voltage Controller B
Capacitor Cell 2 Voltage Controller A
Capacitor Cell 2 Voltage Controller B
Capacitor Cell 3 Voltage Controller A
Capacitor Cell 3 Voltage Controller B
Capacitor Cell 4 Voltage Controller A
Capacitor Cell 4 Voltage Controller B
Capacitor Charge Controller A
Capacitor Charge Controller B
Overall Unit Status: OK
Temperature Loc: upper IOM A
Temperature Loc: lower IOM B
Temperature Loc: left PSU
Temperature Loc: right PSU
Voltage 12V Loc: upper-IOM A
Voltage 5V Loc: upper-IOM A
Voltage 12V Loc: lower-IOM B
Voltage 5V Loc: lower-IOM B
Voltage 12V Loc: left-PSU
Voltage 5V Loc: left-PSU
Voltage 3.3V Loc: left-PSU
Voltage 12V Loc: right PSU
Voltage 5V Loc: right PSU
Voltage 3.3V Loc: right PSU
Current 12V Loc: upper-IOM A
Current 12V Loc: lower-IOM B
Current 12V Loc: left-PSU
Current 5V Loc: left-PSU
Current 12V Loc: right-PSU
Current 5V Loc: right-PSU connUnitSensorType connUnitSensor
Characteristic enclosure(7) enclosure(7) power-supply(5) power-supply(5) power-supply(5) power-supply(5) power-supply(5) power-supply(5) enclosure(7) enclosure(7) power-supply(5) power-supply(5) power-supply(5) power-supply(5) board(8) board(8) board(8) board(8) board(8) board(8) board(8) board(8) board(8) enclosure(7) enclosure(7) enclosure(7) power-supply(5) power-supply(5) enclosure(7) enclosure(7) current current current current current current power power power power power power power power power power power power power power power other other other temperature temperature temperature temperature power power
External details for connUnitPortTable
Table 15 connUnitPortTable index and name values connUnitPortIndex connUnitPortName
1
2
Host Port 1 (Controller A)
Host Port 2 (Controller B)
NEXIO Farad 2300 Series WBI User Guide 97
Table 15 connUnitPortTable index and name values connUnitPortIndex connUnitPortName
3
4
Host Port 1 (Controller A)
Host Port 2 (Controller B)
Configuring SNMP event notification in RAIDar
2. Configure and enable SNMP traps; see
Configuring SNMP notification on page 32.
3. Optionally, configure a user account to receive SNMP traps; see
Configuring user accounts on page 33.
SNMP management
You can manage storage devices using SNMP with a network management system such as HP OpenView, HP
SIM, or HP ISEE. See their documentation for information about loading MIBs, configuring events, and viewing and setting group objects.
In order to view and set system group objects, SNMP must be enabled in the storage system; see
the network management system that intends to access the storage system or receive traps from it. In the storage system, SNMPv3 is configured through the creation and use of SNMP user accounts, as described in
management system.
98 SNMP reference
Enterprise trap MIB
The following pages show the source for the enterprise traps MIB, dhtraps.mib. This MIB defines the content of the SNMP traps that 4000 Series storage systems generate.
-- ------------------------------------------------------
-- Dot Hill Low Cost Array MIB for SNMP Traps
--
-- $Revision: 11692 $
--
-- Copyright 2005 Dot Hill Systems Corp.
-- All rights reserved. Use is subject to license terms.
--
-- ------------------------------------------------------
DHTRAPS-MIB
-- Last edit date: Nov 11th, 2005
DEFINITIONS ::= BEGIN
IMPORTS
enterprises
FROM RFC1155-SMI
TRAP-TYPE
FROM RFC-1215
connUnitEventId, connUnitEventType, connUnitEventDescr
FROM FCMGMT-MIB;
--Textual conventions for this MIB
----------------------------------------------------------------------
-- formerly Box Hill
dothill OBJECT IDENTIFIER ::= { enterprises 347 }
-- Related traps
dhEventInfoTrap TRAP-TYPE
ENTERPRISE dothill
VARIABLES { connUnitEventId,
connUnitEventType,
connUnitEventDescr }
DESCRIPTION
"An event has been generated by the storage array.
Recommended severity level (for filtering): info"
-- Trap annotations are as follows:
--#TYPE "Informational storage event"
--#SUMMARY "Informational storage event # %d, type %d, description: %s"
--#ARGUMENTS {0,1,2}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 6
::= 1
dhEventWarningTrap TRAP-TYPE
ENTERPRISE dothill
VARIABLES { connUnitEventId,
connUnitEventType,
connUnitEventDescr }
DESCRIPTION
NEXIO Farad 2300 Series WBI User Guide 99
"An event has been generated by the storage array.
Recommended severity level (for filtering): warning"
-- Trap annotations are as follows:
--#TYPE "Warning storage event"
--#SUMMARY "Warning storage event # %d, type %d, description: %s"
--#ARGUMENTS {0,1,2}
--#SEVERITY MINOR
--#TIMEINDEX 6
::= 2
dhEventErrorTrap TRAP-TYPE
ENTERPRISE dothill
VARIABLES { connUnitEventId,
connUnitEventType,
connUnitEventDescr }
DESCRIPTION
"An event has been generated by the storage array.
Recommended severity level (for filtering): error"
-- Trap annotations are as follows:
--#TYPE "Error storage event"
--#SUMMARY "Error storage event # %d, type %d, description: %s"
--#ARGUMENTS {0,1,2}
--#SEVERITY MAJOR
--#TIMEINDEX 6
::= 3
dhEventCriticalTrap TRAP-TYPE
ENTERPRISE dothill
VARIABLES { connUnitEventId,
connUnitEventType,
connUnitEventDescr }
DESCRIPTION
"An event has been generated by the storage array.
Recommended severity level (for filtering): critical"
-- Trap annotations are as follows:
--#TYPE "Critical storage event"
--#SUMMARY "Critical storage event # %d, type %d, description: %s"
--#ARGUMENTS {0,1,2}
--#SEVERITY CRITICAL
--#TIMEINDEX 6
::= 4
END
100 SNMP reference
B Using FTP to download logs and update firmware
CAUTION:
• Do not download system logs unless directed to do so by Harris Technical Support.
Although RAIDar is the preferred interface for downloading log data and historical disk-performance statistics and updating firmware, you can also use FTP to do these tasks.
IMPORTANT: Do not attempt to do more than one of the operations in this appendix at the same time. They can interfere with each other and the operations may fail. Specifically, do not try to do more than one firmware update at the same time or try to download system logs while doing a firmware update.
Downloading system logs
To help service personnel diagnose a system problem, you might be asked to provide system log data. You can download this data by accessing the system’s FTP interface and running the get logs command. When both controllers are online, regardless of operating mode, get logs will download a single, compressed zip file that includes:
• User configuration settings from both controllers
• Event logs from both controllers
• SC logs from both controllers
• SC crash dumps from both controllers
• CAPI trace from the controller receiving the command
• MC log from the controller receiving the command
• Controller environment (including data about attached disks, enclosures, and so forth)
Use a command-line-based FTP client; a GUI-based FTP client might not work.
To download system logs
1. In RAIDar, prepare to use FTP:
.
b. Verify that the system’s FTP service is enabled; see
Changing management interface settings
on
on
2. Open a Command Prompt (Windows) or a terminal window (UNIX) and navigate to the destination directory for the log file.
3. Enter:
ftp
controller-network-address
For example:
ftp 10.1.0.9
4. Log in as a user that has permission to use the FTP interface.
5. Enter:
get logs
filename.zip where filename is the file that will contain the logs. It is recommended to choose a filename that identifies the system, controller, and date.
For example:
get logs Storage2_A_20120126.zip
NEXIO Farad 2300 Series WBI User Guide 101
Wait for the message Operation Complete to appear.
6. Quit the FTP session.
7. If the problem to diagnose seems specific to user-interface behavior, repeat step 3
through
controller to collect its unique MC log data.
NOTE: You must uncompress a zip file before you can view the files it contains. To examine diagnostic data, first view store_yyyy_mm_dd__hh_mm_ss.logs.
Transferring log data to a log-collection system (Not supported in Gen 2)
If the log-management feature is configured in pull mode, a log-collection system can access the storage system’s
FTP interface and use the get managed-logs command to retrieve untransferred data from a system log file.
This command retrieves the untransferred data from the specified log to a compressed zip file on the log-collection system. Following the transfer of a log’s data, the log’s capacity status is reset to zero indicate that there is no untransferred data. Log data is controller specific.
For an overview of the log-management feature, see
About managed logs (Not supported) on page 23.
Use a command-line-based FTP client; a GUI-based FTP client might not work.
To transfer log data to a log-collection system
1. In RAIDar, prepare to use FTP:
.
b. Verify that the system’s FTP service is enabled; see
Changing management interface settings
on
on
2. On the log-collection system, open a Command Prompt (Windows) or a terminal window (UNIX) and navigate to the destination directory for the log file.
3. Enter:
ftp
controller-network-address
For example:
ftp 10.1.0.9
4. Log in as a user that has permission to use the FTP interface.
5. Enter:
get managed-logs:
log-type filename.zip where:
•
log-type
specifies the type of log data to transfer:
• crash1
, crash2, crash3, or crash4: One of the SC’s four crash logs.
• ecdebug
: EC log.
• mc
: MC log.
• scdebug
: SC log.
•
filename
is the file that will contain the transferred data. It is recommended to choose a filename that identifies the system, controller, log type, and date.
For example:
get managed-logs:scdebug Storage2-A_scdebug_2011_08_22.zip
Wait for the message Operation Complete to appear.
6. Quit the FTP session.
NOTE: You must uncompress a zip file before you can view the files it contains.
102 Using FTP to download logs and update firmware
Downloading historical disk-performance statistics
CAUTION:
• Do not download historical disk-performance statistics unless directed to do so by Harris Technical Support.
You can access the storage system’s FTP interface and use the get perf command to download historical disk-performance statistics for all disks in the storage system. This command downloads the data in CSV format to a file, for import into a spreadsheet or other third-party application.
The number of data samples downloaded is fixed at 100 to limit the size of the data file to be generated and transferred. The default is to retrieve all the available data (up to six months) aggregated into 100 samples. You can specify a different time range by specifying a start and end time. If the specified time range spans more than
100 15-minute samples, the data will be aggregated into 100 samples.
The resulting file will contain a row of CSV property names and a row for each data sample, as shown in the following example. For property descriptions, see the topic about the disk-hist-statistics basetype in the CLI Reference Guide.
"sample-time","durable-id","serial-number","number-of-ios", ...
"2012-01-26 01:00:00","disk_1.1","PLV2W1XE","2467917", ...
"2012-01-26 01:15:00","disk_1.1","PLV2W1XE","2360042", ...
...
Use a command-line-based FTP client; a GUI-based FTP client might not work.
To retrieve historical disk-performance statistics
1. In RAIDar, prepare to use FTP:
.
b. Verify that the system’s FTP service is enabled; see
Changing management interface settings
on
on
2. Open a Command Prompt (Windows) or a terminal window (UNIX) and navigate to the destination directory for the log file.
3. Enter:
ftp
controller-network-address
For example:
ftp 10.1.0.9
4. Log in as a user that has permission to use the FTP interface.
5. Enter:
get perf[:
date/time-range] filename.csv where:
•
date/time-range
is optional and specifies the time range of data to transfer, in the format: start.yyyy-mm-dd.hh:mm.[AM|PM].end.yyyy-mm-dd.hh:mm.[AM|PM]
. The string must contain no spaces.
•
filename
is the file that will contain the data. It is recommended to choose a filename that identifies the system, controller, and date.
For example:
get perf:start.2012-01-26.12:00.PM.end.2012-01-26.23:00.PM
Storage2_A_20120126.csv
Wait for the message Operation Complete to appear.
6. Quit the FTP session.
NEXIO Farad 2300 Series WBI User Guide 103
Updating firmware
You can update the versions of firmware in controller modules, expansion modules (in drive enclosures), and disks.
TIP: To ensure success of an online update, select a period of low I/O activity. This helps the update complete as quickly as possible and avoids disruptions to host and applications due to timeouts. Attempting to update a storage system that is processing a large, I/O-intensive batch job will likely cause hosts to lose connectivity with the storage system.
IMPORTANT:
• If a vdisk is quarantined, resolve the problem that is causing the vdisk to be quarantined before updating firmware. See information about events 172 and 485 in the Event Descriptions Reference Guide, and
Removing a vdisk from quarantine on page 67.
• If any unwritten cache data is present, firmware update will not proceed. Before you can update firmware, that data must be removed from cache. See information about event 44 in the Event Descriptions Reference Guide and information about the clear cache command in the CLI Reference Guide.
• If the system’s health is Fault, firmware update will not proceed. Before you can update firmware, you must resolve the problem specified by the Health Reason value on the System Overview panel (
Updating controller-module firmware
A controller enclosure can contain one or two controller modules. In a dual-controller system, both controllers should run the same firmware version. You can update the firmware in each controller module by loading a firmware file obtained from the enclosure vendor.
If you have a dual-controller system and the PFU option is enabled, when you update one controller the system automatically updates the partner controller. If PFU is disabled, after updating firmware on one controller you must log into the partner controller’s IP address and perform this firmware update on that controller also.
For best results, the storage system should be in a healthy state before starting firmware update.
NOTE: For information about supported releases for firmware update, see the product’s Release Notes.
To update controller-module firmware
1. Obtain the appropriate firmware file and download it to your computer or network.
2. In RAIDar, prepare to use FTP: a. Determine the network-port IP addresses of the system’s controllers.
b. Verify that the system’s FTP service is enabled.
c. Verify that the user you will log in as has permission to use the FTP interface.
3. Restart the MC in the controller to be updated; or if PFU is enabled, restart the MCs in both controllers. For the procedure, see
Restarting or shutting down controllers on page 64.
4. Open a Command Prompt (Windows) or a terminal window (UNIX) and navigate to the directory containing the firmware file to load.
5. Enter:
ftp
controller-network-address
For example:
ftp 10.1.0.9
6. Log in as an FTP user.
7. Enter:
104 Using FTP to download logs and update firmware
put
firmware-file flash
For example:
put T230R01-01.bin flash
CAUTION: Do not perform a power cycle or controller restart during a firmware update. If the update is interrupted or there is a power failure, the module might become inoperative. If this occurs, contact technical support. The module might need to be returned to the factory for reprogramming.
NOTE: If you attempt to load an incompatible firmware version, the message *** Code Load
Fail. Bad format image. *** is displayed and after a few seconds the FTP prompt is redisplayed. The code is not loaded.
Firmware update typically takes 10 minutes for a controller having current CPLD firmware, or 20 minutes for a controller having downlevel CPLD firmware. If the controller enclosure has attached drive enclosures, allow additional time for each EMP to be updated. This typically takes 3 minutes for an EMP in each drive enclosure.
NOTE: If you are using a Windows FTP client, during firmware update a client-side FTP application issue can cause the FTP session to be aborted. If this issue persists try using RAIDar to perform the update, use another client, or use another FTP application.
If the SC cannot be updated, the update operation is cancelled. If the FTP prompt does not return, quit the FTP session and log in again. Verify that you specified the correct firmware file and repeat the update. If this problem persists, contact technical support.
When firmware update on the local controller is complete, the message Operation Complete is printed, the FTP session returns to the ftp> prompt, and the FTP session to the local MC is closed.
If PFU is enabled, allow an additional 10–20 minutes for the partner controller to be updated.
8. Quit the FTP session.
9. Clear your web browser’s cache, then sign in to RAIDar. If PFU is running on the controller you sign in to, a dialog box shows PFU progress and prevents you from performing other tasks until PFU is complete.
NOTE: After firmware update has completed on both controllers, if the system health is Degraded and the health reason indicates that the firmware version is incorrect, verify that you specified the correct firmware file and repeat the update. If this problem persists, contact technical support.
Updating expansion-module firmware
A drive enclosure can contain one or two expansion modules. Each expansion module contains an EMP. All modules of the same model should run the same firmware version.
Expansion-module firmware is updated in either of two ways:
• When you update controller-module firmware, all expansion modules are automatically updated to a compatible firmware version.
• You can update the firmware in each expansion module by loading a firmware file obtained from the enclosure vendor.
You can specify to update all expansion modules or only specific expansion modules. If you specify to update all expansion modules and the system contains more than one type of enclosure, the update will be attempted on all enclosures in the system. The update will only succeed for enclosures whose type matches the file, and will fail for enclosures of other types.
NEXIO Farad 2300 Series WBI User Guide 105
To update expansion-module firmware
1. Obtain the appropriate firmware file and download it to your computer or network.
2. If you want to update all expansion modules, continue with the next step; otherwise, in RAIDar, determine the address of each expansion module to update: a. In the Configuration View panel, select a drive enclosure.
b. In the enclosure properties table, note each EMP’s bus ID and target ID values. For example, 0 and 63, and
1 and 63. Bus 0 is the bus that is native to a given controller, while bus 1 is an alternate path through the partner controller. It is recommended to perform update tasks consistently through one controller to avoid confusion.
3. In RAIDar, prepare to use FTP: a. Determine the network-port IP addresses of the system’s controllers.
b. Verify that the system’s FTP service is enabled.
c. Verify that the user you will log in as has permission to use the FTP interface.
4. Open a Command Prompt (Windows) or a terminal window (UNIX) and navigate to the directory containing the firmware file to load.
5. Enter:
ftp
controller-network-address
For example:
ftp 10.1.0.9
6. Log in as an FTP user.
7. Either:
• To update all expansion modules, enter:
put
firmware-file encl
• To update specific expansion modules, enter:
put
firmware-file encl:EMP-bus-ID:EMP-target-ID
For example:
put S110R01.bin encl:1:63
CAUTION: Do not perform a power cycle or controller restart during the firmware update. If the update is interrupted or there is a power failure, the module might become inoperative. If this occurs, contact technical support. The module might need to be returned to the factory for reprogramming.
It typically takes 1.5 minutes to update each EMP in a drive enclosure. Wait for a message that the code load has completed.
NOTE: If the update fails, verify that you specified the correct firmware file and try the update a second time. If it fails again, contact technical support.
8. If you are updating specific expansion modules, repeat
for each remaining expansion module that needs to be updated.
9. Quit the FTP session.
10. Verify that each updated expansion module has the correct firmware version.
Updating disk firmware
You can update disk firmware by loading a firmware file obtained from your reseller.
A dual-ported disk can be updated from either controller. A single-ported disk that is in a vdisk or is a dedicated spare for a vdisk must be updated from the controller that owns the vdisk. Attempting to update a single-ported disk from the non-owning controller will not cause any change to the disk.
106 Using FTP to download logs and update firmware
NOTE: Disks of the same model in the storage system must have the same firmware revision.
You can specify to update all disks or only specific disks. If you specify to update all disks and the system contains more than one type of disk, the update will be attempted on all disks in the system. The update will only succeed for disks whose type matches the file, and will fail for disks of other types.
To prepare for update
1. Obtain the appropriate firmware file and download it to your computer or network.
2. Check the disk manufacturer’s documentation to determine whether disks must be power cycled after firmware update.
3. If you want to update all disks of the type that the firmware applies to, continue with the next step; otherwise, in RAIDar, for each disk to update: a. Determine the enclosure number and slot number of the disk.
b. If the disk is associated with a vdisk and is single ported, determine which controller owns the vdisk.
4. In RAIDar, prepare to use FTP: a. Determine the network-port IP addresses of the system’s controllers.
b. Verify that the system’s FTP service is enabled.
c. Verify that the user you will log in as has permission to use the FTP interface.
5. Stop I/O to the storage system. During the update all volumes will be temporarily inaccessible to hosts. If I/O is not stopped, mapped hosts will report I/O errors. Volume access is restored after the update completes.
To update disk firmware
1. Open a Command Prompt (Windows) or a terminal window (UNIX) and navigate to the directory containing the firmware file to load.
2. Enter:
ftp
controller-network-address
For example:
ftp 10.1.0.9
3. Log in as an FTP user.
4. Either:
• To update all disks of the type that the firmware applies to, enter:
put
firmware-file disk
• To update specific disks, enter:
put
firmware-file disk:enclosure-ID:slot-number
For example:
put
firmware-file disk:1:11
CAUTION: Do not power cycle enclosures or restart a controller during the firmware update. If the update is interrupted or there is a power failure, the disk might become inoperative. If this occurs, contact technical support.
It typically takes several minutes for the firmware to load. Wait for a message that the update has succeeded.
NOTE: If the update fails, verify that you specified the correct firmware file and try the update a second time. If it fails again, contact technical support.
5. If you are updating specific disks, repeat
for each remaining disk to update.
6. Quit the FTP session.
7. If the updated disks must be power cycled:
NEXIO Farad 2300 Series WBI User Guide 107
a. Shut down both controllers by using RAIDar.
b. Power cycle all enclosures as described in your product’s Setup Guide.
8. Verify that each disk has the correct firmware revision.
108 Using FTP to download logs and update firmware
C Using SMI-S
This appendix provides information for network administrators who are managing the 4000 Series from a storage management application through the SMI-S. SMI-S is a SNIA standard that enables interoperable management for storage networks and storage devices.
SMI-S replaces multiple disparate managed object models, protocols, and transports with a single object-oriented model for each type of component in a storage network. The specification was created by SNIA to standardize storage management solutions. SMI-S enables management applications to support storage devices from multiple vendors quickly and reliably because they are no longer proprietary. SMI-S detects and manages storage elements by type, not by vendor.
The key SMI-S components are:
• WBEM. A set of management and internet standard technologies developed to unify the management of enterprise computing environments. WBEM includes the following specifications:
• xmlCIM: defines XML elements, conforming to DTD, which can be used to represent CIM classes and instances
• CIM Operations over HTTP: defines a mapping of CIM operations onto HTTP; used as a transport mechanism
• CIM. The data model for WBEM. Provides a common definition of management information for systems, networks, applications and services, and allows for vendor extensions. SMI-S is the interpretation of CIM for storage. It provides a consistent definition and structure of data, using object-oriented techniques. The standard language used to define elements of CIM is MOF. UML is used to create a graphical representation
(using boxes and lines) of objects and relationships.
• SLP. Enables computers and other devices to find services in a local area network without prior configuration.
SLP has been designed to scale from small, unmanaged networks to large enterprise networks.
Embedded SMI-S array provider
The embedded SMI-S array provider provides an implementation of SMI-S 1.5 using cim-xml over HTTPS.
SMI-enabled management clients such as HP SIM or HP Storage Essentials can perform storage management tasks such as monitoring, configuring or event-management. The provider supports the Array and Server profiles with additional (or supporting subprofiles). The Server profile provides a mechanism to tell the client how to connect and use the embedded provider. The Array profile has the following supporting profiles and subprofiles:
• Array profile
• Block Services package
• Physical Package package
• Health package
• Multiple Computer System subprofile
• Masking and Mapping profile
• FC Target Ports subprofile
• SAS Target Ports subprofile
• Disk Drive Lite profile
• Extent Composition subprofile
• Storage Enclosure profile
• Fan profile
• Power Supply profile
• Sensors profile
• Access Points subprofile
• Location subprofile
• Software Inventory subprofile
• Block Server Performance subprofile
NEXIO Farad 2300 Series WBI User Guide 109
• Job Control subprofile
• Storage Enclosure subprofile (if expansion enclosures are attached)
• Disk Sparing subprofile
• CIM Alert and Lifecycle indications are supported.
• SLPv2 is supported.
• HTTPS using SSL encryption is supported on default port 5989. HTTP is supported on default http port
5988. (Both ports cannot be enabled at the same time.)
SMI-S implementation
SMI-S is implemented with the following components:
• CIM server (called CIMOM), which listens for WBEM requests (CIM operations over HTTP) from a CIM client, and responds.
• CIM provider, which communicates to a particular type of managed resource (for example, Dot Hill
AssuredSAN 4000 Series storage systems), and provides the CIMOM with information about them. In theory, providers for multiple types of devices (for example, 4000 Series storage systems and Brocade switches) can be plugged into the same CIMOM. However, in practice, all storage vendors provide the CIMOM and a single provider together, and they do not co-exist well with solutions from other vendors.
These components may be provided in several different ways:
• Embedded agent: The hardware device has an embedded SMI-S agent. No other installation of software is required to enable management of the device.
• SMI solution: The hardware or software ships with an agent that is installed on a host. The agent needs to connect to the device and obtain unique identifying information.
SMI-S architecture
The architecture requirements for the embedded SMI-S Array provider are to work within the MC architecture, use limited disk space, use limited memory resources and be as fast as a proxy provider running on a server. The provider is an MC application and works by making MC CLI requests. An SMI-S cache caches these requests for
30 to 60 seconds. The disk space used is about 3 MB without qualifiers and 8 MB with qualifiers. The CIMOM used is the open source SFCB CIMOM.
SFCB is a lightweight CIM daemon that responds to CIM client requests and supports the standard CIM XML over http/https protocol. The provider is a CMPI provider and uses this interface. To reduce the memory footprint, a third-party package called CIMPLE ( www.simplewbem.org
) is used. For more information on SFCB go to sblim.cvs.sourceforge.net/sblim/sfcb/README?view=markup .
About the 4000 Series SMI-S provider
The CF100 release passes all SMI-S 1.5 tests and is CTP 1.5 certified. Full provisioning is supported.
The 4000 Series SMI-S provider is a full-fledged embedded provider implemented in the firmware. It provides an industry-standard WBEM-based management framework. SMI-S clients can interact with this embedded provider directly and do not need an intermediate proxy provider. The provider supports active management features such as RAID provisioning.
Each 4000 Series is supported, including FC, SAS platforms. The classes for Dot Hill are DHS_XXX. The device namespace for Dot Hill is /root/dhs.
The embedded CIMOM can be configured either to listen to secure SMI-S queries from the clients on port 5989 and require credentials to be provided for all queries, or to listen to unsecure SMI-S queries from the clients on port 5988. This provider implementation complies with the SNIA SMI-S specification version 1.5.0.
NOTE: Port 5989 and port 5988 cannot be enabled at the same time.
The namespace details are given below.
110 Using SMI-S
• Implementation Namespace - root/dhs
• Interop Namespace - root/interop
The embedded provider set includes the following providers:
• Instance Provider
• Association Provider
• Method Provider
• Indication Provider
The embedded provider supports the following CIM operations:
• getClass
• enumerateClasses
• enumerateClassNames
• getInstance
• enumerateInstances
• enumerateInstaneceNames
• associators
• associatorNames
• references
• referenceNames
• invokeMethod
SMI-S profiles
SMI-S is organized around profiles, which describe objects relevant for a class of storage subsystem. SMI-S includes profiles for arrays, FC HBAs, FC switches, and tape libraries. Other storage devices are expected to be added in the future. Profiles are registered with the CIM server and advertised to clients using SLP. HP SIM determines which profiles it intends to manage, and then uses the CIM model to discover the actual configurations and capabilities.
Table 16 Supported SMI-S profiles
Profile/subprofile
/package
Description
Array profile
Block Services package
Describes RAID array systems. It provides a high-level overview of the array system.
Defines a standard expression of existing storage capacity, the assignment of capacity to
Storage Pools, and allocation of capacity to be used by external devices or applications.
Physical Package package Models information about a storage system’s physical package and optionally about internal sub-packages.
Health package
Server profile
Defines the general mechanisms used in expressing health in SMI-S.
Defines the capabilities of a CIM object manager based on the communication mechanisms that it supports.
FC Target Ports profile Models the FC specific aspects of a target storage system.
SAS Target Ports subprofile Models the SAS specific aspects of a target storage system.
Access Points subprofile
Fan profile
Provides addresses of remote access points for management services.
Specializes the DMTF Fan profile by adding indications.
Power Supply profile Specializes the DMTF Power Supply profile by adding indications.
Profile Registration profile Models the profiles registered in the object manager and associations between registration classes and domain classes implementing the profile.
Software subprofile Models software or firmware installed on the system.
NEXIO Farad 2300 Series WBI User Guide 111
Table 16 Supported SMI-S profiles
Profile/subprofile
/package
Description
Masking and Mapping profile
Models device mapping and masking abilities for SCSI systems.
Disk Drive Lite profile
Extent Composition
Models disk drive devices.
Provides an abstraction of how it virtualizes exposable block storage elements from the underlying Primordial storage pool.
Location subprofile
Sensors profile
Models the location details of product and its sub-components.
Specializes the DMTF Sensors profile.
Software Inventory profile Models installed and available software and firmware.
Storage Enclosure profile Describes an enclosure that contains storage elements (e.g., disk or tape drives) and enclosure elements (e.g., fans and power supplies).
Multiple Computer System subprofile
Models multiple systems that cooperate to present a virtual computer system with additional capabilities or redundancy.
Job Control subprofile Provides the ability to monitor provisioning operations, such as creating volumes, and mapping volumes to hosts.
Disk Sparing subprofile Provides the ability to describe the current spare disk configuration, to allocate/de-allocate spare disks, and to clear the state of unavailable disk drives.
Block Server Performance subprofile
The implementation of the block server performance subprofile allows use of the CIM_XXXStatisticalData classes and their associations, and the GetStatisticsCollection, CreateManifestCollection, AddOrModifyManifest and RemoveManifest methods.
CIM
Supported CIM operations
SFCB provides a full set of CIM operations including GetClass, ModifyClass, CreateClass, DeleteClass,
EnumerateClasses, EnumerateClassNames, GetInstance, DeleteInstance, CreateInstance, ModifyInstance,
EnumerateInstances, EnumerateInstanceNames, InvokeMethod (MethodCall), ExecQuery, Associators,
AssociatorNames, References, ReferenceNames, GetQualifier, SetQualifier, DeleteQualifier,
EnumerateQualifiers, GetProperty and SetProperty.
CIM Alerts
The implementation of alert indications allow a subscribing CIM client to receive events such as FC cable connects, Power Supply events, Fan events, Temperature Sensor events and Disk Drive events.
If the storage system’s SMI-S interface is enabled, the system will send events as indications to SMI-S clients so that SMI-S clients can monitor system performance. For information about enabling the SMI-S interface, see
SMI-S configuration on page 114.
The event categories below pertain to FRU assemblies and certain FRU components.
Table 17 CIM Alert indication events
FRU/Event category
Controller
Hard Disk Drive
Fan
Corresponding SMI-S class
DHS_Controller
DHS_DiskDrive
DHS_PSUFan
Operational status values that would trigger alert conditions
Down, Not Installed, OK
Unknown, Missing, Error, Degraded, OK
Error, Stopped, OK
112 Using SMI-S
Table 17 CIM Alert indication events
FRU/Event category
Power Supply
Temperature Sensor
Battery/Super Cap
FC Port
SAS Port
Corresponding SMI-S class
DHS_PSU
DHS_OverallTempSensor
DHS_SuperCap
DHS_FCPort
DHS_SASTargetPort
Operational status values that would trigger alert conditions
Unknown, Error, Other, Stressed, Degraded, OK
Unknown, Error, Other, Non-Recoverable Error, Degraded, OK
Unknown, Error, OK
Stopped, OK
Stopped, OK
Life cycle indications
The SMI-S interface provides CIM life cycle indications for changes in the physical and logical devices in the storage system. The SMI-S provider supports all mandatory elements and certain optional elements in SNIA
SMI-S specification version 1.5.0. CQL and WQL are both supported, with some limitations to the CQL indication filter.
Table 18 Life cycle indications
Profile or subprofile
Element description and name WQL or
CQL
Block
Services
Block
Services
SELECT * FROM CIM_InstCreation WHERE SourceInstance ISA CIM_StoragePool
Send life cycle indication when a vdisk is created or deleted.
SELECT * FROM CIM_InstCreation WHERE SourceInstance ISA CIM_StorageVolume
Send life cycle indication when a volume is created or deleted.
Block
Services
Disk Drive
Lite
SELECT * FROM CIM_InstCreation WHERE SourceInstance ISA CIM_DiskDrive
Send life cycle indication when a disk drive is inserted or removed.
Fan
SELECT * FROM CIM_InstModification WHERE SourceInstance ISA CIM_LogicalDevice
Send life cycle indication when disk drive (or any logical device) status changes.
SELECT * FROM CIM_InstCreation WHERE SourceInstance ISA CIM_Fan
Send life cycle indication when a fan is powered on or off.
Both
Both
Both
Both
Both
Job Control SELECT * FROM CIM_InstModification WHERE SourceInstance ISA CIM_ConcreteJob AND
SourceInstance.OperationalStatus=17 AND SourceInstance.OperationalStatus=2
Send life cycle indication when a create or delete operation completes for a volume, LUN.
WQL
Masking and
Mapping
Masking and
Mapping
SELECT * FROM CIM_InstCreation WHERE SourceInstance ISA CIM_AuthorizedSubject
Send life cycle indication when a host privilege is created or deleted.
SELECT * FROM CIM_InstCreation WHERE SourceInstance ISA CIM_ProtocolController
Send life cycle indication when create/delete storage hardware ID (add/remove hosts).
Both
Both
Masking and
Mapping
Multiple
Computer
System
Multiple
Computer
System
SELECT * FROM CIM_InstCreation WHERE SourceInstance ISA
CIM_ProtocolControllerForUnit
Send life cycle indication when a LUN is created, deleted, or modified.
SELECT * FROM CIM_InstCreation WHERE SourceInstance ISA CIM_ComputerSystem
Send life cycle indication when a controller is powered on or off.
SELECT * FROM CIM_InstModification WHERE SourceInstance ISA CIM_ComputerSystem
AND SourceInstance.OperationalStatus <> PreviousInstance.OperationalStatus
Send life cycle indication when a logical component degrades or upgrades the system.
Both
Both
WQL
NEXIO Farad 2300 Series WBI User Guide 113
Table 18 Life cycle indications (continued)
Profile or subprofile
Element description and name
Multiple
Computer
System
Target
Ports
Target
Ports
SELECT * FROM CIM_InstModification WHERE SourceInstance ISA CIM_RedundancySet
AND SourceInstance.RedundancyStatus <> PreviousInstance.RedundancyStatus
Send life cycle indication when the controller active-active configuration changes.
SELECT * FROM CIM_InstCreation WHERE SourceInstance ISA CIM_FCPort
Send life cycle indication when a target port is created or deleted.
SELECT * FROM CIM_InstModification WHERE SourceInstance ISA CIM_FCPort AND
SourceInstance.OperationalStatus <> PreviousInstance.OperationalStatus
Send life cycle indication when the status of a target port changes.
WQL or
CQL
WQL
Both
WQL
SMI-S configuration
In the default SMI-S configuration:
• The secure SMI-S protocol is enabled, which is the recommended protocol for SMI-S.
• The SMI-S interface is enabled for the manage user.
The following table lists the CLI commands relevant to the SMI-S protocol:
Action
Enable secure SMI-S port 5989 (and disable port 5988)
Disable secure SMI-S port 5989
Enable unsecure SMI-S port 5988 (and disable port
5989)
Disable unsecure SMI-S port 5988 (and enable port
5989)
Enable unsecure SMI-S port 5988
See the current status
CLI command set protocols smis enabled set protocols smis disabled set protocols usmis disabled set protocols usmis enabled set protocol usmis enabled show protocols
To configure the SMI-S interface for other users:
1. Log in as manage
2. If the user does not already exist, create one using this command: create user level manage username
3. Type this command: set user username interfaces wbi,cli,smis,ftp
Listening for managed-logs notifications (Not supported in Farad Gen 2)
For use with the storage system’s managed logs feature, the SMI-S provider can be set up to listen for notifications that log files have filled to a point that are ready to be transferred to a log-collection system. For more information about the managed logs feature, see
About managed logs (Not supported) on page 23.
To set up SMI-S to listen for managed logs notifications:
1. In the CLI, enter this command: set advanced-settings managed-logs enabled
2. In an SMI-S client: a. Subscribe using the SELECT * FROM CIM_InstCreation WHERE SourceInstance ISA
CIM_LogicalFile
filter.
114 Using SMI-S
b. Subscribe using the SELECT * FROM CIM_InstDeletion WHERE SourceInstance ISA
CIM_LogicalFile
filter.
Testing SMI-S
Use an SMI-S certified client for SMI-S 1.5. HP has clients such as HP SIM and HP Storage Essentials. Other common clients are Microsoft System Center, IBM Tivoli, EMC CommandCenter and CA Unicenter. Common
WBEM CLI clients are Pegasus cimcli and Sblim’s wbemcli.
Testing also employs a Java Swing GUI called CIM Browser. To certify that the array provider is SMI-S 1.5 compliant, SNIA requires that the providers pass the CTP tests.
LUN Masking and Mapping operations
The implementation of the Masking and Mapping subprofile’s extrinsic methods allows CIM clients to create
LUNs by mapping volumes to logical ports. The ExposePaths method is fully implemented and simplifies this operation to 1 step. The CreateStorageHardwareID and DeleteStorageHardwareID methods all CIM clients to create and remove hosts.
Troubleshooting
The table below provides information on the most common situations needing troubleshooting.
Table 19 Troubleshooting
Problem
Unable to connect to the embedded
SMI-S Array provider.
HTTP Error (Invalid username/password or 401
Unauthorized).
Want to connect securely as user name my_xxxx.
Unable to discover via SLP.
Unable to determine if SMI-S is running.
Cause
SMI-S protocol is not enabled.
User preferences are configurable for each user on the storage system.
Check that the user has access to the smis interface and set the user preferences to support the smis
interface, if necessary. See SMI-S configuration on page 114 for
instructions on how to add users.
Also verify the supplied credentials.
Need to add user Log in to the array as manage.
Type create user level manage my_xxxuser
and then type set user my_xxxuser interfaces wbi,cli,smis
SLP multicast has limited range
(known as hops).
Initial troubleshooting.
Solution
Log in to the array as manage and type: set protocol smis enabled.
Move the client closer to the array or set up a SLP DA server or using unicast requests.
Install wbemcli on a Linux system by typing apt-get install wbemcli
.
Type wbemcli -nl -t
-noverify ein
'https://manage:!manage
@:5989/root/dhs:cim_com putersystem'
NEXIO Farad 2300 Series WBI User Guide 115
116 Using SMI-S
D Administering a log-collection system
The log-collection system is not supported in Farad Gen 2.
A log-collection system receives log data that is incrementally transferred from a storage system whose managed logs feature is enabled, and is used to integrate that data for display and analysis. For information about the managed logs feature, see
About managed logs (Not supported) on page 23.
Over time, a log-collection system can receive many log files from one or more storage systems. The administrator organizes and stores these log files on the log-collection system. Then, if a storage system experiences a problem that needs analysis, that system’s current log data can be collected and combined with the stored historical log data to provide a long-term view of the system’s operation for analysis.
The managed logs feature monitors the following controller-specific log files:
• EC log, which includes EC debug data, EC revisions, and PHY statistics
• SC debug log and controller event log
• SC crash logs, which include the SC boot log
• MC log
Each log-file type also contains system-configuration information.
How log files are transferred and identified
Log files can be transferred to the log-collection system in two ways, depending on whether the managed logs feature is configured to operate in push mode or pull mode:
• In push mode, when log data has accumulated to a significant size, the storage system sends notification events with attached log files through email to the log-collection system. The notification specifies the storage-system name, location, contact, and IP address, and contains a single log segment in a compressed zip file. The log segment will be uniquely named to indicate the log-file type, the date/time of creation, and the storage system. This information will also be in the email subject line. The file name format is logtype_yyyy_mm_dd__hh_mm_ss.zip
.
• In pull mode, when log data has accumulated to a significant size, the system sends notification events via email, SNMP traps, or SMI-S to the log-collection system. The notification will specify the storage-system name, location, contact, and IP address and the log-file type (region) that needs to be transferred. The storage system's FTP interface can be used to transfer the appropriate logs to the log-collection system, as described in
Transferring log data to a log-collection system (Not supported in Gen 2) on page 102.
Log-file details
• SC debug-log records contain date/time stamps of the form mm/dd hh:mm:ss.
• SC crash logs (diagnostic dumps) are produced if the firmware fails. Upon restart, such logs are available, and the restart boot log is also included. The four most recent crash logs are retained in the storage system.
• When EC debug logs are obtained, EC revision data and SAS PHY statistics are also provided.
• MC debug logs transferred by the managed logs feature are for five internal components: appsv, mccli, logc
, web, and snmpd. The contained files are log-file segments for these internal components and are numbered sequentially.
Storing log files
It is recommended to store log files hierarchically by storage-system name, log-file type, and date/time. Then, if historical analysis is required, the appropriate log-file segments can easily be located and can be concatenated into a complete record.
NEXIO Farad 2300 Series WBI User Guide 117
For example, assume that the administrator of a log-collection system has created the following hierarchy for logs from two storage systems named Storage1 and Storage2:
In push mode, when the administrator receives an email with an attached ecdebug file from Storage1, the administrator would open the attachment and unzip it into the ecdebug subdirectory of the Storage1 directory.
In pull mode, when the administrator receives notification that an SC debug log needs to be transferred from
Storage2, the administrator would use the storage system’s FTP interface to get the log and save it into the scdebug
subdirectory of the Storage2 directory.
118 Administering a log-collection system
Glossary
Additional Sense
Code/Additional Sense
Code Qualifier
Advanced Encryption
Standard
AES
.
.
ASC/ASCQ atomic write auto-write-through available disk
AWT
CAPI
Advanced Encryption Standard. A specification for the encryption of data using a symmetric-key algorithm.
Additional Sense Code/Additional Sense Code Qualifier. Information on sense data returned by a
SCSI device.
A mode that guarantees if a failure (such as I/O being aborted or a controller failure) interrupts a data transfer between a host and the storage system, controller cache will contain either all the old data or all the new data, not a mix of old and new data. This option has a slight performance cost because it maintains a secondary copy of data in cache so that if a data transfer is not completed, the old cache data can be restored.
.
A disk that is not being used in a vdisk , is not configured as a spare, and is not in the
It is available to be configured as a part of a vdisk or as a spare.
Auto-write-through. A setting that specifies when the RAID controller cache mode automatically changes from write-back to write-through.
Configuration Application Programming Interface. A proprietary protocol used for
and the
MC in a controller module. CAPI is always enabled.
chunk size
CIM
The amount of contiguous data that is written to a
vdisk member before moving to the next
member of the vdisk.
Common Information Model. The data model for
WBEM . It provides a common definition of
management information for systems, networks, applications and services, and allows for vendor extensions.
CIM Query Language
.
CIMOM Common Information Model Object Manager. A component in between management applications and providers.
that handles the interactions
CMIP Common Management Interface Protocol. A model that allows modification of information on managed objects.
comma separated values
.
Common Information
Model
.
Common Information
Model Object Manager
Common Management
Interface Protocol compatible disk
Configuration
Application
Programming Interface
A disk that can be used to replace a failed member disk of a vdisk because it both has enough
capacity and is of the same type (SAS SSD, enterprise SAS, or midline SAS) as the disk that failed.
complex programmable logic device
.
NEXIO Farad 2300 Series WBI User Guide 119
Coordinated Universal
Time
CPLD
.
CQL
CRC
Complex programmable logic device. An electronic component used to build reconfigurable digital circuits. It can replace large numbers of logic gates.
CIM Query Language.
Cyclic Redundancy Check. A mathematical algorithm that, when implemented in software or hardware, can be used to detect errors in data.
Comma separated values. A format to store tabular data in plain-text form.
.
CSV
Cyclic Redundancy
Check
DAS Direct Attached Storage. A digital storage system attached to a storage system or workstation without the use of a network.
. Data Encryption
Standard
DDR dedicated spare default mapping
Double data rate. A class of memory integrated circuits use in computers.
A disk that is reserved for use by a specific vdisk
to replace a failed disk. See compatible disk .
Host-access settings that are configured when a
volume is created, and that apply to all hosts that
are not explicitly mapped to that volume using different settings. See also explicit mapping
and
DES
DHCP
Data Encryption Standard. An algorithm for the encryption of electronic data.
Dynamic Host Configuration Protocol. A network configuration protocol for hosts on IP networks.
. Direct Attach Storage
Distributed Management
Task Force
DMTF Distributed management task force. An industry organization that develops and maintains standards for system management.
double data rate drive spin down
DSD dual-port disk
.
Drive spin down. A power-saving feature that monitors disk activity in the storage system and spins down inactive SAS disks based on user-selectable policies.
A disk in a dual-controller environment connected to both controllers so it has two data paths, achieving fault tolerance.
. Dynamic Host
Configuration Protocol dynamic spare
EC
that is automatically assigned, if the dynamic spares option is enabled, to replace a failed disk in a
Expander controller. A processor located in the SAS expander in each controller module and
expansion module that controls the SAS expander and provides SES
functionality. See also
.
electromagnetic interface
EMI
EMP
Electromagnetic interface.
Enclosure management processor. An EC
subsystem that provides
power supply and fan status, and the presence or absence of disks.
enclosure management processor expander controller explicit mapping
.
Access settings for a host to a volume
that override the volume’s default mapping. See also
120 Glossary
extrinsic methods
FC-AL
FRU global spare
HBA
Methods which are particular to a specific class in
Fibre Channel Arbitrated Loop. The FC topology in which devices are connected in a one-way loop.
Fibre Channel Arbitrated
Loop
. field-programmable gate array
field-replaceable unit
FPGA
.
Field-programmable gate array. An integrated circuit designed to be configured after manufacturing.
Field-replaceable unit. A part that can be removed and replaced by the user or support technician without having to send the product to a repair facility.
A
that is reserved for use by any vdisk to replace a failed disk.
host port
Host Bus Adapter. A device that facilitates I/O processing and physical connectivity between a host and the storage system.
A port on a controller module that interfaces to a host computer, either directly or through a network switch.
host bus adapter
Input/Output Module intrinsic methods
IOM large form factor
LBA leftover
.
Methods inherited from CIM and present in all classes such as getclass, createinstance,
enumerateinstances, and associatorNames in SMI-S
.
Input/Output Module. An IOM can be either a controller module or an expansion module.
.
Logical Block Address. The address used for specifying the location of a block of data.
The state of a disk that the system has excluded from a vdisk because the timestamp in the disks’s metadata is older than the timestamp of other disks in the vdisk, or because the disk was not detected during a rescan. A leftover disk cannot be used in another vdisk until the disk’s metadata is cleared; for information and cautions about doing so, see documentation topics about clearing disk metadata.
LFF
LIP
Large form factor. A type of disk drive.
Loop Initialization Primitive. An FC primitive used to determine the loop ID for a controller.
Logical Block Address
.
Logical Unit Number
loop
Loop Initialization
Primitive
LUN
MAC Address
topology.
Logical Unit Number. A number that identifies a mapped volume
to a host.
Media Access Control Address. A unique identifier assigned to network interfaces for communication on a network.
management controller
Management
Information Base
. masking
MC
Media Access Control
Address
A
volume -mapping setting that specifies no access to that volume by hosts. See also
default mapping and explicit mapping .
Management controller. A processor located in a controller module that is responsible for human-computer interfaces and computer-computer interfaces, including the
interfaces, and interacts with the SC .
NEXIO Farad 2300 Series WBI User Guide 121
Memory reference code
. metadata
Data in the first sectors of a disk drive that stores all disk-,
information including vdisk membership or spare ID, vdisk ownership, volumes host mapping of volumes, and results of the last media scrub.
-specific
MIB
MMF
Management Information Base. A database used for managing the entities in SNMP.
Multimode fiber.
MRC
Multimode fiber
Memory reference code.
. native command queuing
NCQ Native command queuing.
network port An ethernet port on a controller module through which its
is connected to the network.
network time protocol
.
NTP object identifier
Network time protocol.
OID orphan data
Partner Firmware
Upgrade
PCBA
Object Identifier. A number assigned to devices in a network for identification purposes.
See
.
Printed circuit board assembly. A printed circuit board populated with electronic components.
. persistent group reservations
PFU
PGR
PHY
Partner Firmware Upgrade. The automatic update of the partner controller when the user updates firmware on one controller in a dual-controller system.
Persistent group reservations.
physical layer point-to-point
POST
Power-on Self Test
Power Supply Unit printed circuit board assembly
One of two hardware components that form a physical connection between devices in a SAS network that enables transmission of data.
.
The FC topology where two ports are directly connected.
Power-On Self Test. Tests that run immediately after a device is powered on.
.
PSU real-time clock recipe
RTC
Power Supply Unit. The power supply FRU
.
.
A pseudo-client code added to SMI-S
to demonstrate usage of methods and associations.
Real-time clock. A circuit in the controller module that maintains the date and time. The RTC has a battery backup that maintains the time even when there is no power attached to the module.
SC Storage Controller. A processor located in a controller module that is responsible for RAID controller functions. The SC is also referred to as the RAID controller.
SCSI Enclosure Services
. secure hash algorithm
. secure shell
Secure Sockets Layer
SEEPROM
.
Serial electrically erasable programmable ROM. A type of nonvolatile (persistent if power removed) computer memory used as
ID devices.
122 Glossary
Self-Monitoring
Analysis and Reporting
Technology serial electrically erasable programmable
ROM service Location
Protocol
SES
.
.
SFCB
SFF
SHA
SIM single-port disk
SLP
SCSI Enclosure Services. The protocol that allows the initiator to communicate with the enclosure using SCSI commands.
Small Footprint CIM Broker.
Small form factor. A type of disk drive.
Secure Hash Algorithm. A cryptographic hash function.
Systems Insight Manager. HP-owned and operated technology supporting servers and storage devices.
A disk with a single data path not connected to both controllers so it is not fault tolerant.
Single-port disk types are identified with the suffix -S.
Service Location Protocol. Enables computers and other devices to find services in a local area network without prior configuration.
Small Footprint CIM
Broker small form factor
SMART
SMI-S
SNIA
.
Self-Monitoring Analysis and Reporting Technology. A monitoring system for disk drives that monitors reliability indicators for the purpose of anticipating disk failures and reporting those potential failures.
Storage Management Initiative - Specification. The
SNIA standard that enables interoperable
management of storage networks and storage devices.
The interpretation of
for storage. It provides a consistent definition and structure of data, using object-oriented techniques.
Storage Networking Industry Association. An association regarding storage networking technology and applications.
SSH
SSL storage controller
Storage Management
Initiative - Specification
Secure Shell. A network protocol for secure data communication.
Secure Sockets Layer. A cryptographic protocol that provides security over the internet.
.
Storage Networking
Industry Association
Systems Insight
Manager
UCS Transformation
Format - 8-bit
ULP
.
Unified
LUN Presentation. A RAID controller feature that enables a host to access mapped
s through either controller’s host ports. ULP incorporates ALUA extensions.
. Unified LUN
Presentation
Uninterruptible Power
Source
NEXIO Farad 2300 Series WBI User Guide 123
unwritable cache data Cache data that has not been written to disk and is associated with a
or whose disks are not online. If the data is needed, the volume’s disks must be brought online. If the data is not needed it can be cleared. Unwritable cache data is also called orphan data.
UPS
UTC
Uninterruptible Power Source.
Coordinated universal time. The primary time standard by which the world regulates clocks and time. It replaces Greenwich Mean Time.
UTF-8 vdisk virtual disk volume
WBEM
UCS transformation format - 8-bit. A variable-width encoding that can represent every character
in the Unicode character set used for the CLI and WBI
interfaces.
A virtual disk comprised of the capacity of one or more physical disks. The number of disks that a vdisk can contain is determined by its RAID level.
A portion of the capacity of a vdisk that can be presented as a storage device to a host.
Web-Based Enterprise Management. A set of management and internet standard technologies
developed to unify the management of enterprise computing environments. See also CIM .
.
web-based interface/web-browser interface
WBI Web-based interface/web-browser interface. The primary interface for managing the system. A user can enable the use of HTTP, HTTPS for increased security, or both.
Web-Based Enterprise
Management
Windows Management
Instrumentation Query
Language
.
World Wide Name
.
World Wide Node Name
.
World Wide Port Name
WQL Windows Management Instrumentation Query Language.
WWN World Wide Name. A globally unique 64-bit number that identifies a device used in storage technology.
WWNN
WWPN
World Wide Node Name. A globally unique 64-bit number that identifies a node.
World Wide Port Name. A globally unique 64-bit number that identifies a port.
124 Glossary
Index
Symbols
* (asterisk) in option name
A
ALUA
array
ASC/ASCQ
asterisk (*) in option name
Atomic Write
audience, document
B base for size representations
bytes versus characters
C cache configuring auto-write-through triggers and behaviors
configuring host access to
configuring system settings
configuring volume settings
CAPI
characters versus bytes
chunk
CIM
CIMOM
CMPI
color codes for storage space
CompactFlash properties
configuration browser
first-time
system limits
Configuration View component icons
Configuration View panel, using
Configuration Wizard, using
controller module properties
controllers restarting or shutting down
using FTP to update firmware
using WBI to update firmware
conventions, document
Coordinated Universal Time (UTC)
CPLD
CRC
current owner
D
DAS
date and time about
configuring
debug data saving to a file
debug logs downloading
dedicated spare
,
dedicated spares adding and removing
default mapping
DES
DHCP configuring
configuring with Configuration Wizard
disk channels rescanning
disk metadata clearing
disk performance about monitoring historical
resetting (clearing) historical statistics
saving (downloading) historical statistics
disk properties
disk settings configuring
disk state (how used) values
disks configuring background scrub
configuring SMART
configuring spin down for available and global-spare
enabling vdisk reconstruction by replacing failed
scheduling spin down for all
showing data transfer rate
using FTP to retrieve performance statistics
using FTP to update firmware
using WBI to update firmware
DMTF
document audience
conventions
prerequisite knowledge
related documentation
drive spin down configuring for a vdisk
configuring for available and global-spare disks
scheduling for all disks
DSD
dual-port disk
dynamic spare
dynamic spares configuring
E
EC
EMP
NEXIO Farad 2300 Series WBI User Guide 125
EMP polling rate configuring
enclosure viewing information about
enclosure properties
event log viewing
event notification configuring email settings
configuring SNMP settings
configuring with Configuration Wizard
sending a test message
event severity icons
expansion module properties
expansion port properties
explicit mapping
Extrinsic Methods
F
FC-AL
firmware using FTP to update controller module
using FTP to update disk drive
using FTP to update expansion module
using WBI to update controller module
using WBI to update disk
using WBI to update expansion module
firmware versions
FPGA
FTP downloading system logs
retrieving disk-performance statistics
updating controller module firmware
updating disk drive firmware
updating expansion module firmware
using with the log-management feature
G global spare
global spares
adding and removing
H hardware versions
HBA
help using online
host adding
changing mappings
changing name
viewing information about
host access to cache configuring
host mapping properties
host port properties
host ports configuring
126 Index configuring with Configuration Wizard
resetting
host properties
hosts about
removing
viewing information about all
I
I/O module properties
icons event severity
storage-system component
WBI communication status
In port properties
Intrinsic Methods
L
LBA
leftover
leftover disk
link rate adjustment
link speed configuring FC
LIP
log data saving to a file
log management about
sending a test message
using FTP
log-collection system administering
logs downloading debug
loop IDs configuring FC
LUN
LUNs configuring response to missing
M
MAC address
managed logs about
administering a log-collection system
enabling/disabling
Management Controller
Management Information Base
management interface services configuring
configuring with Configuration Wizard
mapping volumes
masked volume
maximum physical and logical entities supported
MC
Media Access Control Address
metadata
clearing disk
MIB
missing LUN response configuring
N network port
network port properties
network ports configuring
configuring with Configuration Wizard
NTP about
configuring
O
OID
orphan data
Out port properties
P passwords
PCBA
performance monitoring
PFU
point-to-point
POST
power supply properties
preferred owner
prerequisite knowledge, document
priority configuring utility
Provisioning Wizard using to create a vdisk with volumes and mappings
provisioning, first-time
R
RAID levels about
RAIDar Storage Management Utility
read-ahead caching optimizing
Recipe
related documentation
rescan disk channels
restarting controllers
restoring the system’s default configuration settings
S
SC
schedule deleting
modifying
schedule properties
scrub configuring background disk
configuring background vdisk
SCSI MODE SELECT
command configuring handling of
SCSI SYNCHRONIZE CACHE
command configuring handling of
See Advanced Encryption Standard
SEEPROM
selective storage presentation
SES
SHA
shutting down controllers
sign out, auto setting user
viewing remaining time
signing in to the WBI
signing out of the WBI
SIM
single-port disk
size representations about
SLP
SMART
configuring
SMI-S
SNIA
SNMP configuring traps
enterprise trap MIB
enterprise traps
external details for connUnitPortTable
external details for connUnitRevsTable
external details for connUnitSensorTable
FA MIB 2.2 behavior
FA MIB 2.2 objects, descriptions, and values
management
MIB-II behavior
overview
setting event notification
sorting a table
spares about
See also dedicated spare, dynamic spare, and global spare
SSH
SSL
storage system
synchronize-cache mode configuring
system configuration limits
restoring default configuration settings
viewing event log
viewing information about
system information configuring
NEXIO Farad 2300 Series WBI User Guide 127
configuring with Configuration Wizard
system properties
System Status panel using
system utilities configuring
T tables sorting
task schedule
temperature configuring controller shutdown for high
time and date about
configuring
U
ULP
units for size representations
users about user accounts
adding
changing default passwords with Configuration Wizard
maximum that can sign in
modifying
removing
UTC
utility priority configuring
V vdisk aborting scrub
aborting verification
changing name
changing owner
configuring
configuring drive spin down
creating
creating with the Provisioning Wizard
expanding
removing from quarantine
scrubbing
verifying redundant
viewing information about
vdisk health values
vdisk performance graphs
vdisk properties
vdisk reconstruction replacing failed disks to enable
setting spares to enable
vdisk status values
vdisks about
configuring background scrub
deleting
viewing information about all
volume changing default mapping
changing explicit mappings
changing name
configuring
configuring cache settings
creating
expanding
viewing information about
volume cache options about
volume mapping about
changing default mapping for multiple volumes
changing explicit mapping for multiple volumes
unmapping multiple volumes
volume mapping properties
volume masking
volume properties
volume set creating
volumes about
deleting
W
WBEM
WBI
about
signing in
signing out
WBI communication status icon
WBI session hang
web-browser buttons to avoid
web-browser interface
web-browser setup
write-back caching
write-through caching
WWN
WWPN
128 Index