Peerless ACC570W is a versatile ceiling plate designed for mounting audio-visual equipment. With a maximum load capacity of 150 lbs, it can securely support heavy equipment like TVs, projectors, and speakers. Installation is straightforward, allowing for flush or extension column mounting depending on your needs. The grommet included ensures a snug fit and prevents the plate from rotating once installed. Whether you have wood joists, concrete ceilings, or cinder blocks, the ACC570W comes with the necessary hardware for a secure and stable installation.
Reklamë
Reklamë
Installation and Assembly - Round Ceiling Plate
NOTE: Read entire instruction sheet before beginning installation and assembly.
Models: ACC570, ACC570S,
ACC570W
This product is UL Listed. It must be installed by a qualified professional installer.
R
Maximum UL Load Capacity: 150 lb (68 kg)
Before you begin, make sure all parts shown are included with your product.
Parts List
Description
A round ceiling plate
B #14 x 2.5" wood screw
C M5 x .8 x 10 mm phillips screw
D M5 x .8 x 10 mm socket pin screw
E 4 mm allen wrench
F rubber grommet
G concrete anchor
ACC 570
Qty. Part #
ACC 570S ACC 570W
Part # Part #
1 055-1798 055-4798 055-2798
4 5S1-015-C03 5S1-015-C04 5S1-015-C04
1 520-9250
1 520-1164
1 560-9646
1 530-9401
4 590-0097
520-2005
520-2031
560-9646
530-9401
590-0097
520-2005
520-2031
560-9646
530-9401
590-0097
A B C D E
F G
Parts may appear slightly different than illustrated.
WARNING
• Do not begin to install your Peerless product until you have read and understood the instructions and warnings contained in this Installation Sheet. If you have any questions regarding any of the instructions or warnings, please call Peerless customer care at 1-800-865-2112.
• This product should only be installed by someone of good mechanical aptitude, has experience with basic building construction, and fully understands these instructions.
• Make sure that the supporting surface will safely support the combined load of the equipment and all attached hardware and components.
• Never exceed the Maximum UL Load Capacity.
• If mounting to wood joists or wood beam ceilings, make sure that mounting screws are anchored into the center of the joists or beams. Use of an "edge to edge" stud finder is highly recommended.
• Always use an assistant or mechanical lifting equipment to safely lift and position equipment.
• Tighten screws firmly, but do not overtighten. Overtightening can damage the items, greatly reducing their holding power.
1 of 4 ISSUED: 11-14-07 SHEET #: 054-9054-5
For customer care call 1-800-729-0307 or 708-865-8870.
Visit the Peerless Web Site at www.peerlessmounts.com
1 Place grommet (F) into hole of ceiling plate (A).
NOTE: Make sure grommet overlaps retaining collar. Grommet may require some force to fit in hole and will appear slightly deformed.
A
F
RETAINING
COLLAR
WARNING
• For safety, extension column must be locked to threaded fitting with screw.
Extension Column Applications
2
Insert end of extension column into threaded fitting of ceiling plate (A). Tighten four or five complete turns.
Align slot in extension column with one of the small holes in the side of the threaded fitting. Insert and tighten one M5 x 10 mm phillips screw (C) into hole to lock extension column to threaded fitting.
NOTE: For security option, use M5 socket pin screw (D) in place of screw (C). Tighten using 4 mm allen wrench (E).
C
THREADED
FITTING
SLOT
A
EXTENSION
COLUMN
(SOLD
SEPARATELY)
Flush Mounting Applications
2 Screw flush mount from top of ceiling plate (A) as shown in fig. 2. Tighten four or five complete turns.
Align slot in flush mount tube with one of the small holes in the side of the threaded fitting. Insert and tighten one M5 x 10 mm phillips screw (C) into hole to lock flush mount tube to threaded fitting.
NOTE: For security option, use M5 socket pin screw (D) in place of screw (C). Tighten using 4 mm allen wrench (E).
fig. 2
FLUSH MOUNT
TUBE (SOLD
SEPARATELY)
A
Visit the Peerless Web Site at www.peerlessmounts.com
2 of 4 ISSUED: 11-14-07 SHEET #: 054-9054-5
For customer care call 1-800-729-0307 or 708-865-8870.
Installation to Wood Joist Finished Ceilings, Exposed Wood Joists, or Wood Beam Ceilings
WARNING
• Installer must verify that the supporting surface will safely support the combined load of the equipment and all attached hardware and components.
• Tighten wood screws so that ceiling plate is firmly attached, but do not overtighten. Overtightening can damage the screws, greatly reducing their holding power.
• Never tighten in excess of 80 in. • lb (9 N.M.).
• Make sure that mounting screws are anchored into the center of the wood joist or wood beam. The use of an
"edge to edge" stud finder is highly recommended.
• Hardware provided is for attachment of mount through standard thickness drywall or plaster into wood joist or wood beam ceilings. Installers are responsible to provide hardware for other types of mounting situations.
3 Drill two 5/32" (4 mm) dia. holes to a minimum depth of 2.5" (64 mm). Attach ceiling plate (A) to the joist center using two #14 x 2.5" wood screws (B) as shown. Tighten wood screws (B) using 3/8" (10 mm) socket wrench so ceiling plate (A) is firmly attached.
A
B
Visit the Peerless Web Site at www.peerlessmounts.com
3 of 4 ISSUED: 11-14-07 SHEET #: 054-9054-5
For customer care call 1-800-729-0307 or 708-865-8870.
Installation to Solid Concrete or Cinder Block
WARNING
• When installing Peerless ceiling plates on cinder block, verify that you have a minimum of 1-3/8" of actual concrete thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount in a solid part of the block, generally 1" minimum from the side of the block. Cinder block must meet
ASTM C-90 specifications. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a hammer drill to avoid breaking out the back of the hole when entering a void or cavity.
• Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.
• Make sure that the supporting surface will safely support the combined load of the equipment and all attached hardware and components.
3 Use ceiling plate (A) as a template to mark holes.
Drill four 1/4" (6 mm) dia. holes to a minimum depth of 2.5" (64 mm). Insert four anchors (G) in holes flush with ceiling as shown in figure 3.1.
Place ceiling plate (A) over anchors (G) and secure with #14 x 2.5" (6 mm x 65 mm) wood screws (B).
Tighten wood screws (B) using 3/8" (10 mm) socket wrench to firmly attach ceiling plate (A).
See figures 3.2 and 3.3.
fig. 3.1
CONCRETE
CEILING
G
Drill holes and insert anchors (G).
fig. 3.2
A
WARNING
• Always attach concrete anchors directly to load-bearing concrete.
• Never attach concrete anchors to concrete covered with plaster, drywall, or other finishing material. If mounting to concrete surfaces covered with a finishing surface is unavoidable, the finishing surface must be counterbored as shown below. Be sure concrete anchors do not pull away from concrete when tightening screws. If plaster/ drywall is thicker than 5/8", custom fasteners must be supplied by installer. (Not evaluated by UL)
B G
Place ceiling plate (A) over anchors (G) and secure with screws (B).
fig. 3.3
WARNING
• Tighten screws so that ceiling plate is firmly attached, but do not overtighten. Overtightening can damage screws, greatly reducing their holding power.
• Never tighten in excess of 80 in. • lb (9 N.M.).
Tighten all fasteners.
G
ceiling plate
INCORRECT concrete ceiling plate
CORRECT concrete
A
plaster/ dry wall plaster/ dry wall
Visit the Peerless Web Site at www.peerlessmounts.com
B
4 of 4 ISSUED: 11-14-07 SHEET #: 054-9054-5
For customer care call 1-800-729-0307 or 708-865-8870.
© 2007, Peerless Industries, Inc. All rights reserved.
All other brand and product names are trademarks or registered trademarks of their respective owners.
Shkarko
Reklamë
Veçoritë kryesore
White
Wood
Maximum weight capacity: 68 kg