Leggett & Platt Simplicity Queen, Split Cal-King adjustable base Owners manual
Reklamë
Reklamë
owners manual
SIMPLICITY
*Queen (shown without mattress)
*Split Cal-King
ENGLISH
SPANISH
FRENCH
LPAdjustableBases.com
Spanish translation begins on page 24.
La traducción en español inicia en la página 24.
French Canadian translation begins on page 46.
La traduction en Français débute à la page 46.
If adjustable base does not operate or if parts are missing, call:
800-888-3078
Do not contact retail store or dealer.
ADVISORY
IMPORTANT INFORMATION
READ THE FOLLOWING INFORMATION CAREFULLY BEFORE USING THIS PRODUCT
FOR OPTIMUM ADJUSTABLE BASE
OPERATION, USE A GROUNDED, ELECTRICAL
SURGE PROTECTION DEVICE (NOT
INCLUDED). FAILURE TO USE A SURGE
PROTECTION DEVICE COULD COMPROMISE
SAFETY OR CAUSE PRODUCT MALFUNCTION.
ELECTRICAL RATING
Electrical components are rated for 110/120 voltage, 60Hz, 100 watt.
ELECTRICAL GROUNDING
This product is equipped with a polarized or grounded electrical power cord. The power cord will only fit into a grounded, electrical surge protection device (not included) or a grounded electrical outlet.
WARRANTY WARNING
Do not open any control boxes, motors or remote control devices (with the exception of the remote control and power down box battery compartments). The product warranty will be void if these components are tampered with. Do not attempt to alter component wiring or adjust or modify the structure of the product in any way or the warranty will be void. Any repair or replacement of base parts must be performed by authorized personnel.
LUBRICATION
This product is designed to be maintenance free. The lift motors are permanently lubricated and sealed—no additional lubrication is required. Do not apply lubricant to lift motor lead screws or any nylon nuts or the base may inadvertently creep downward from the elevated position.
PRODUCT RATINGS
The base lift motors are
not designed for
continuous use. Reliable operation and full life expectancy will be realized as long as the lift motor operation does not exceed five (5) minutes over a forty-five (45) minute period, or approximately 11% duty cycle.
Note:
Massage equipped bases are not designed for continuous, extended massage operation.
Massage systems are rated for a maximum
of 2 hours of use within any 6 hour period.
Any attempt to circumvent or exceed product ratings will shorten the life expectancy of the product and may void the warranty.
The recommended maximum weight (including mattress) is 550 lb (249 kg) distributed evenly across the base. This product is not designed to support or lift this amount in the head or foot sections alone.
Note: Exceeding the recommended weight restrictions could damage the base and void the warranty.
For best performance, consumers should enter and exit the adjustable base with the base in the flat (horizontal) position. Avoid placing entire weight on head or foot section of the base, including when in the raised position.
DO
NOT STAND ON BASE AT ANY TIME.
UL (Underwriters Laboratories) recognized components.
CFR 1633 approved for use with most mattresses.
Assembled in USA.
Performance Models Simplicity Owners Manual 99301470-b
3
ADVISORY
IMPORTANT INFORMATION
READ THE FOLLOWING INFORMATION CAREFULLY BEFORE USING THIS PRODUCT
SMALL CHILDREN / PETS WARNING
After the base is unboxed, immediately dispose of packaging material as it can smother small children and pets. To avoid injury, children or pets should not be allowed to play under or on the base. Children should not operate this base without adult supervision.
PACEMAKER WARNING
This product produces a vibrating sensation.
It is possible that individuals with heart-assist pacemakers may experience a sensation similar to exercise. Consult physician for complete information.
FCC COMPLIANCE
Components meet Class B digital device rating (Part 15, FCC rules) for residential use.
Adjustable bases generate, use and may radiate radio frequency energy. Radio communication may be affected if not installed and operated as recommended in this manual. Changes or modifications not expressively approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Radio frequency = 310MHz.
HOSPITAL USE DISCLAIMER
This base is designed for in-home use only. It
is not approved for hospital use and does not comply with hospital standards. Do not use this base with tent type oxygen therapy equipment, or use near explosive gases.
LOCKING CASTER SAFETY FEATURE
Many adjustable bases are equipped with locking casters to prohibit the base from movement. For best results, place rubber caster cups under locking casters when the base is located on smooth or hard surface flooring—it is possible for locking caster equipped beds to slide without the use of rubber caster cups.
To activate locking casters, push down on the lock tab. To disengage the locking mechanism, push up on the lock tab (see illustration below).
SERVICE REQUIREMENTS
Service technicians are not responsible for moving furniture, removing headboards and footboards or any items required to perform maintenance on the base. In the event the technician is unable to perform service due to lack of accessibility, the service call will be billed to the purchaser and the service will have to be rescheduled.
LOCKING CASTER
DETAIL
LOCK
4
Performance Models Simplicity Owners Manual 99301470-b
LIFTING/LOWERING MECHANISMS
The lift/lower feature will emit a minimal humming sound during operation. This is normal.
During operation, the lift arm wheels make contact with the platform support of the base.
This applies slight tension on the moving components and resonance is reduced to a minimum level. If excessive noise or vibration is experienced, reverse the movement action (up or down) of the base with the remote control. This should realign the base’s activating mechanisms to the proper operational position.
MASSAGE OPERATION
The massage feature will emit a minimal tone during operation. This is normal. When the massage level is increased, motor resonance will intensify accordingly.
ACOUSTICS
LOCATION ENVIRONMENT
The level of sound experienced during operation is directly related to the location environment. For example, when a base is located on a hardwood floor with the massage feature in operation, a vibrating tone will be audible. To minimize this resonance, place a piece of carpet, or rubber caster cups, under each leg or caster of the base.
It is possible to experience vibration or noise from the headboard brackets, headboards or footboards if mounting bolts are not firmly tightened.
FABRIC CLEANING INFORMATION
Spot clean only with water based shampoo or foam upholstery cleaner. Pretest a small, inconspicuous area before proceeding. Do not over wet. Do not use solvents to spot clean. Pile fabrics may require brushing with a non-metallic, stiff bristle brush to restore appearance.
Hot water extraction or steam cleaning is not a recommended cleaning
method.
To prevent overall soiling, frequent vacuuming or light brushing with a non-metallic stiff bristle brush to remove dust and grime is recommended. When cleaning a spill, blot immediately to remove spilled material. Clean spots or stains from the outside to the middle of the affected area to prevent circling. Use a professional furniture cleaning service when an overall soiled condition is apparent.
Performance Models Simplicity Owners Manual 99301470-b
5
INSTALLATION
For installation and setup, complete the following procedures, in the order indicated below and on the following pages:
STEP 1
Before discarding any packing materials, check the adjustable base shipping carton and verify the following items are included:
• (1) Mattress Retainer
• (4) Bed Legs
• (4) Locking Leg Casters
• (1) Remote Control
• (1) Owners Manual
• (1) Warranty Activation Card
• (1) Quick Setup Guide
OWNERS MANUAL
MATTRESS
RETAINER
(1 per base)
WARRANTY
ACTIVATION CARD
QUICK SETUP GUIDE
REMOTE CONTROL
LOCKING LEG CASTER
(4 pieces)
6
Performance Models Simplicity Owners Manual 99301470-b
LEG
(4 pieces)
STEP 2
Remove the hardware box. Cut the zip-tie and remove the mattress retainer.
STEP 3
Install (4) legs into the base frame. Simply screw each leg into a tapped hole at the corner of the base frame ( FIGURE 1).
Insert casters into the bottom of each bed leg.
AT LEAST TWO PEOPLE ARE
RECOMMENDED FOR HANDLING AND
MOVING ADJUSTABLE BASE.
FIGURE 1
CASTERS – PRESS-FIT
INTO BOTTOM OF LEGS
(IF APPLICABLE)
DO NOT ATTEMPT TO SCREW
LEGS INTO ANY OTHER INSERTS.
THIS WILL DAMAGE PRODUCT.
LEGS – SCREW INTO
TAPPED HOLE AT
EACH CORNER
STEP 4
Carefully lift the adjustable base from the shipping carton, keeping the unit top-side-down. Remove and extend out power cord from base.
POWER CORDS MUST NOT INTERFERE WITH
ANY ADJUSTABLE BASE MECHANISMS.
STEP 5
Remove the plastic packaging from the base frame. Carefully rotate the adjustable base over to position the base so it is resting on its legs.
Performance Models Simplicity Owners Manual 99301470-b
7
INSTALLATION
STEP 6
Plug electrical power cord into a working, grounded electrical outlet.
Note: An electrical surge protection device is recommended (not included).
STEP 7
Install batteries in remote control (4-AAA, included) ( FIGURE 2). Briefly activate all functions of the base with the remote control to verify all features are in working order. If base does not operate, refer to the
Troubleshooting section of this manual.
FIGURE 2
STEP 8
Return base to the level position.
8
Performance Models Simplicity Owners Manual 99301470-b
INSTALLATION
STEP 9
Install mattress retainer at the foot end of the adjustable base as follows: a. Locate grommeted holes at foot end of base.
b. Place mattress retainer ends into grommeted holes in top surface of adjustable base ( FIGURE 3). Press down until horizontal retainer section is flush against base.
FIGURE 3
MATTRESS
RETAINER
FOOT END OF BASE
NOTE: If base is to be set up without a headboard, install mattress to complete basic installation. If headboard is to be installed, proceed to Headboard Bracket
Installation. (Headboard Bracket sold as accessory.)
Performance Models Simplicity Owners Manual 99301470-b
9
INSTALLATION
HEADBOARD BRACKET INSTALLATION (optional accessory)
Install headboard brackets to the base frame. When attaching (2) twin size units to a king size headboard an optional swing hinge kit (see accessory section) may be used to connect the twin units.
IN ORDER TO AVOID A PERSON OR PET
BEING CAUGHT IN THE SPACE REFERENCED
BELOW WHILE THE BED IS IN MOTION,
THE BOTTOM OF THE HEADBOARD CROSS
MEMBER MUST BE POSITIONED SO THAT
THERE IS NO MORE THAN 3 INCHES
(76.2MM) BETWEEN THE HEADBOARD AND
THE TOP OF THE MATTRESS (FIGURE 4). DO
NOT EXCEED 3 INCHES (76.2MM). FAILURE
TO FOLLOW THIS INSTRUCTION COULD
RESULT IN SERIOUS PERSONAL INJURY OR
DEATH.
NOTE
FAILURE TO FOLLOW HEADBOARD BRACKET
INSTALLATION INSTRUCTIONS MAY CAUSE
HEADBOARD BRACKET INTERFERENCE WITH
BASE FOAM DURING BASE OPERATION.
BASE FOAM OR BASE COVER DAMAGE
COULD RESULT.
FIGURE 4
3 inches MAX
.
Headboard cross member location must not exceed 3 inches (76.2mm) from the top of the mattress.
10
Performance Models Simplicity Owners Manual 99301470-b
INSTALLATION
STEP 10
Install headboard brackets to the base frame as follows: a. Raise the head section of the base (with remote control) to gain access to the base frame.
b. Locate channel connector kit ( FIGURE 5). On one side of base frame, locate (2) holes for channel connector mounting ( FIGURE 6).
c. Position channel connector so that the flat side is flush against base frame. Attach channel connector to base frame using (2) 1½ inch long hex head bolts/nuts ( FIGURE 6). Tighten bolts. Note: For units with
74” base length, use inner mounting holes. For units with 80” base length, use outer mounting holes (FIGURES 5 and 6).
FIGURE 5
80” BASE
LENGTH
MOUNTING
HOLES
74” BASE
LENGTH
MOUNTING
HOLES
FIGURE 6
74” BASE
LENGTH
MOUNTING
HOLES
(2) 1-1/2 INCH LONG
HEX HEAD BOLTS/NUTS
Performance Models Simplicity Owners Manual 99301470-b
11
INSTALLATION
d. Using (2) 3 inch long carriage bolts/nuts, attach (1) headboard bracket channel to (1) channel connector ( FIGURE 7). Hand tighten bolts/nuts (loosely) to allow adjustment of the headboard bracket channels.
FIGURE 7
USE (2) 3 INCH LONG CARRIAGE
BOLTS TO ATTACH HEADBOARD
BRACKET CHANNEL TO BASE FRAME
SLIDE BRACKET
ASSEMBLIES IN OR
OUT TO ACHIEVE
POSITION
HEADBOARD
BRACKET
CHANNEL
(queen size shown)
e. Attach (1) headboard bracket flange to one of the bracket channels with (2) 1 inch long hex head bolts/nuts ( FIGURE 8). Tighten bolts.
f. Repeat procedure to attach the other headboard bracket.
FIGURE 8
USE (2) 1 INCH LONG HEX
HEAD BOLTS TO ATTACH
HEADBOARD BRACKET
FLANGE TO BRACKET
CHANNEL
ADJUST AS
REQUIRED TO
ACHIEVE POSITION
12
Performance Models Simplicity Owners Manual 99301470-b
HEADBOARD
BRACKET
FLANGE
INSTALLATION
g. When installing a headboard, footboard, or four-piece surround (case good), allow for 1.5 inches (38.1mm) to 2 inches (50.8mm) of clearance at the head and foot of the bed and a minimum of ½ inch to ¾ inch on the sides.
h. Firmly tighten the 3 inch carriage bolts of both headboard bracket channels.
i. Measure the distance (center-to-center) between the mounting holes in the headboard.
j. Measure the center-to-center distance between the mounting slots of the headboard bracket flanges.
k. If bracket flange adjustment is required to accept the headboard, remove the 1 inch headboard bracket flange bolts and move flanges side-to-side for the adjustment. Reinstall bolts and tighten.
l. Install headboard.
STEP 11
Install mattress on adjustable base.
Typical Simplicity adjustable base installation is now complete.
Performance Models Simplicity Owners Manual 99301470-b
13
REMOTE CONTROL FUNCTION
TRANSMISSION INDICATOR LIGHT
Verifies a button is being pressed and data is being sent to the base.
FOOT UP/DOWN BUTTONS
Press and hold to raise or lower the foot section.
WAVE LOW BUTTON
Press and hold—after the wave has been activated—to decrease wave speed. To turn wave off, press and hold until wave stops.
FOOT MASSAGE BUTTONS
To activate the foot massage, press and release the increase button.
Adjust massage intensity by pressing and holding the increase or decrease
button. To turn off, press and hold the decrease button until the massage turns off.
TV POSITION BUTTON
Press to adjust the base to the preprogrammed TV viewing position to maximize comfort and entertainment. This position is reprogrammable using the memory
button. To reprogram, adjust base to desired position and/or massage/ wave function, press the memory
button, then press the tv position
button to save the setting.
FLAT BUTTON
Press to adjust the base to the level position.
CUSTOM BUTTON
The custom button is preprogrammed to the level position.
To reprogram to a custom position, adjust base to desired position and/ or massage/wave function, press the memory button, then press the
custom button to save the setting.
NOTE
REMOTE CONTROL REQUIRES FOUR (4) AAA SIZE BATTERIES. TO CONSERVE
BATTERY LIFE, THE TRANSMITTER TURNS OFF ALL FUNCTIONS WHEN ANY BUTTON
IS PRESSED FOR MORE THAN 50 SECONDS.
14
Performance Models Simplicity Owners Manual 99301470-b
HEAD UP/DOWN BUTTONS
Press and hold to raise or lower the head section.
WAVE HIGH BUTTON
After the head and/or foot massager/s have been activated and the desired intensity has been achieved, press to turn the wave on. Press and hold to increase wave speed.
HEAD MASSAGE BUTTONS
To activate the head massage, press and release the increase button.
Adjust massage intensity by pressing and holding the increase or decrease
button. To turn off, press and hold the decrease button until the massage turns off.
ZERO GRAVITY BUTTON
Press to adjust the base to the preprogrammed reclined position for optimum weight distribution allowing total comfort and relaxation. This position is reprogrammable using the memory button. To reprogram, adjust base to desired position and/ or massage/wave function, press the
memory button, then press the zero
gravity button to save the setting.
MEMORY BUTTON
See TV position button, zero gravity button, or the custom button for memory button use .
REMOTE CONTROL PROGRAMMING (1 remote control - 1 base)
STEP 1
Unplug the adjustable base electrical power cord. Wait 30 seconds, then plug the cord back into the power source.
STEP 2
On the remote control, simultaneously press and hold the foot up and tv position buttons
(
FIGURE 9). The transmission indicator light
will flash slowly and then flash rapidly to
indicate programming mode. Continue to hold for 5 seconds and then release the buttons.
One remote control is now programmed to operate one base.
FOOT UP
BUTTON
TRANSMISSION
INDICATOR LIGHT
TV POSITION
BUTTON
FIGURE 9
Performance Models Simplicity Owners Manual 99301470-b
15
REMOTE CONTROL PROGRAMMING (2 remote controls - 1 base)
STEP 1
Unplug the adjustable base electrical power cord. Wait 30 seconds, then plug the cord back into the power source.
STEP 2
On remote control 1, simultaneously press and hold the foot up and tv position buttons
( FIGURE 9). The transmission indicator light
will flash slowly and then flash rapidly to
indicate programming mode. Continue to hold for 5 seconds and then release the buttons.
STEP 3
Repeat Step 1 and Step 2 with remote control 2.
Two remote controls are now programmed to operate one base.
REMOTE
CONTROL 1
REMOTE
CONTROL 2
FOOT UP
BUTTON
TRANSMISSION
INDICATOR LIGHT
NOTE
OPERATE ONLY ONE (1) REMOTE CONTROL
AT A TIME. OPERATING TWO (2) REMOTE
CONTROLS AT THE SAME TIME WILL
MOMENTARILY BLOCK BOTH RF SIGNALS
AND PREVENT BOTH CONTROLS FROM
FUNCTIONING.
TV POSITION
BUTTON
FIGURE 9
16
Performance Models Simplicity Owners Manual 99301470-b
REMOTE CONTROL PROGRAMMING (1 remote control - 2 bases)
STEP 1
Unplug both adjustable bases from the electrical power source. Wait 30 seconds, then plug the cord for base 1 back into the power source.
STEP 2
On the remote control, simultaneously press and hold the foot up and tv position buttons
( FIGURE 9). The transmission indicator light
will flash slowly and then flash rapidly to
indicate programming mode. Continue to hold for 5 seconds and then release the buttons.
STEP 3
Repeat Step 1 and Step 2 with base 2.
One remote control is now programmed to operate two bases.
FOOT UP
BUTTON
BASE 1
BASE 2
TRANSMISSION
INDICATOR LIGHT
TV POSITION
BUTTON
FIGURE 9
Performance Models Simplicity Owners Manual 99301470-b
17
REMOTE CONTROL PROGRAMMING (2 remote controls - 2 bases)
STEP 1 (BASE 1)
Unplug the adjustable base electrical power cord.
Wait 30 seconds, then plug the cord back into the power source.
STEP 2
On remote control 1, simultaneously press and hold the foot up and tv position buttons (FIGURE 9). The
transmission indicator light will flash slowly and then
flash rapidly to indicate programming mode. Continue to hold for 5 seconds and then release the buttons.
STEP 3
Repeat Step 1 and Step 2 with remote control 2.
STEP 4 (BASE 2)
Unplug the adjustable base electrical power cord.
Wait 30 seconds, then plug the cord back into the power source.
STEP 5
On remote control 1, simultaneously press and hold the foot up and tv position buttons (FIGURE 9). The
transmission indicator light will flash slowly and then
flash rapidly to indicate programming mode. Continue to hold for 5 seconds and then release the buttons.
STEP 6
Repeat Step 4 and Step 5 with remote control 2.
Two remote controls are now programmed to operate two bases.
REMOTE
CONTROL 1
REMOTE
CONTROL 2
FOOT UP
BUTTON
TV POSITION
BUTTON
BASE 1
BASE 2
TRANSMISSION
INDICATOR LIGHT
NOTE
OPERATE ONLY ONE (1) REMOTE CONTROL
AT A TIME. OPERATING TWO (2) REMOTE
CONTROLS AT THE SAME TIME WILL
MOMENTARILY BLOCK BOTH RF SIGNALS
AND PREVENT BOTH CONTROLS FROM
FUNCTIONING.
FIGURE 9
18
Performance Models Simplicity Owners Manual 99301470-b
REMOTE CONTROL PROGRAMMING (separating 2 bases)
STEP 1 (BASE 1)
Unplug the adjustable base electrical power cord.
Wait 30 seconds, then plug the cord back into the power source.
STEP 2
On remote control 1, simultaneously press and hold the foot up and tv position buttons (FIGURE 9). The
transmission indicator light will flash slowly and then
flash rapidly to indicate programming mode. Continue to hold for 5 seconds and then release the buttons.
STEP 3
Repeat Step 1 and Step 2 with remote control 1.
Note: Wait 90 seconds before proceeding to Step 4.
STEP 4 (BASE 2)
Unplug the adjustable base electrical power cord.
Wait 30 seconds, then plug the cord back into the power source.
STEP 5
On remote control 2, simultaneously press and hold the foot up and tv position buttons (FIGURE 9). The
transmission indicator light will flash slowly and then
flash rapidly to indicate programming mode. Continue to hold for 5 seconds and then release the buttons.
STEP 6
Repeat Step 4 and Step 5 with remote control 2.
Independent remote control operation is now restored (remote control 1 operating base 1; remote control 2 operating base 2).
FOOT UP
BUTTON
TV POSITION
BUTTON
REMOTE CONTROL 1
REMOTE CONTROL 2
BASE 1
BASE 2
TRANSMISSION
INDICATOR LIGHT
NOTE
OPERATE ONLY ONE (1) REMOTE CONTROL
AT A TIME. OPERATING TWO (2) REMOTE
CONTROLS AT THE SAME TIME WILL
MOMENTARILY BLOCK BOTH RF SIGNALS
AND PREVENT BOTH CONTROLS FROM
FUNCTIONING.
FIGURE 9
Performance Models Simplicity Owners Manual 99301470-b
19
TROUBLESHOOTING
If the adjustable base fails to operate, investigate the symptoms and possible solutions provided in the chart below:
SYMPTOM
Remote control illuminates and appears to be operable, but will not activate base.
No features of the base will activate.
Remote control will not illuminate.
Head or foot section will elevate, but will not return to the horizontal (flat) position.
Excessive massage motor noise.
SOLUTION
• Verify power cord is plugged into a working, grounded electrical outlet.
A grounded, electrical surge protection
device is recommended. Test outlet by plugging in another working appliance.
• Program the remote control (see Remote Control
Programming section of this manual for programming procedures).
• Unplug power cord, wait 30 seconds and plug in to reset electronic components.
• Electrical circuit breaker may be tripped. Check electrical service breaker box to verify.
• Defective surge protection device or electrical outlet.
Test outlet by plugging in another working appliance.
• Replace batteries in the remote control.
• Base mechanism may be obstructed. Elevate base and check for obstruction. Remove obstruction.
• Head section may be too close to the wall.
• Headboard may be too close the edge of the mattress.
Verify a 1.5” (38.1mm) to 2” (50.8mm) distance between headboard brackets and mattress. Adjust if required.
• Verify headboard brackets were removed during installation. Remove headboard brackets if still attached to the underneath side of base.
• If base is located on hard surface flooring, place carpet pieces or rubber caster cups under each leg or caster of the base. (See accessory sheet for rubber caster cup order information.)
• Elevate the head or foot section a short distance (with the remote control) to realign the lift/lower mechanisms with the bed support platform.
• Verify that the base is not positioned against a wall, nightstand, or other object that may cause vibration or noise.
• If base is installed over a bed frame, verify massage motors are not causing bed frame (or bed frame components) to vibrate.
• Verify that headboard attachment hardware is tightened firmly (if used).
20
Performance Models Simplicity Owners Manual 99301470-b
ACCESSORIES
OPTIONAL EQUIPMENT
Contact customer service toll free (800-888-3078) to order the accessories indicated in the chart below.
ACCESSORY DESCRIPTION
CODE IMAGE
Head Board Brackets-TXL 4B6117
Head Board Brackets-FXL/Q
4B6118
Push-in Locking Casters
(set of 4)
4B1806
Bed Link Kit
(connects two bases together)
4B7410
Rubber Caster Cups
(set of 4)
4” Legs (set of 4)
5” Legs (set fo 4)
7” Legs (set of 4)
4B1034
4B1833
4B2100
4B2101
Performance Models Simplicity Owners Manual 99301470-b
21
1 YEAR, 3 YEAR AND 25 YEAR LIMITED WARRANTY
In this warranty: “
Adjustable base” means the adjustable bed foundation sold by L&P to the dealer. The “adjustable base” does not include the mattress. “ L&P” means Leggett & Platt, Incorporated. “Purchaser” and “You” both mean the consumer who is the original purchaser of this adjustable base made by L&P. This warranty is not transferrable. “
Warranty
Commencement Date” means either (i) the date You purchased a new and unused L&P adjustable base or (ii) the date of manufacture of this adjustable base if You purchased an L&P adjustable base that has been used as floor or display model.
L&P warrants this adjustable base to You on the terms and over the reducing periods of time set out below. All warranty claims require notice from You to be given to L&P in the manner set out below, and to be received by L&P inside the applicable warranty time period.
1ST YEAR FULL WARRANTY
For the first year from the Warranty Commencement Date, your adjustable base is warranted against non-excluded defects in L&P’s workmanship or materials. During the first year from the Warranty Commencement Date, L&P will repair or replace (at no cost to You) any defective adjustable base part, and L&P will pay all authorized labor and transportation costs associated with the repair or replacement of any parts found to be defective.
ADDITIONAL TERMS AND CONDITIONS
This warranty requires notice to be given to L&P of any claim for repairs or replacement parts.
2ND & 3RD YEAR LIMITED WARRANTY
During the second and third year from the Warranty
Commencement Date, L&P will replace any adjustable base part found to be defective and not excluded by this warranty. You are responsible to pay all service and transportation costs related to the costs of receiving and installation of the new part.
EXCLUSIONS:
This warranty does not apply; (a) to any damage caused by You; (b) if there has been any repair or replacement of adjustable base parts by an unauthorized person; (c) if the adjustable base has been mishandled (whether in transit or by other means), subjected to physical or electrical abuse or misuse, or otherwise operated in any manner inconsistent with the operation and maintenance procedures outlined in the Owner’s Manual and this warranty; (d) to damage to mattresses, fabric, cables, electrical cords or items supplied by dealers (contact the dealer for warranty information on these items); (e) if there has been any modification of the adjustable base
without prior written consent by L&P; or (f) to costs for unnecessary service calls, including costs for in-home service calls solely for the purpose of educating You about the adjustable base or finding a satisfactory power connection.
4TH YEAR TO END OF 25TH YEAR LIMITED WARRANTY
Starting in the fourth year from the Warranty
Commencement Date and through to the end of the 25th year from the Warranty Commencement Date, L&P will replace steel and mechanical base parts found to be defective and not excluded by this warranty.
This warranty does not cover any electronics, electrical components,
drive motors or massage motors. You are responsible to pay all service and transportation costs related to receiving and installation of the new part and a portion of the cost of the replacement steel and mechanical part, based on the number of months that the base has been owned by you since the fourth anniversary of the
Warranty Commencement Date. By the end of the 25th year, no portion of the replacement cost is covered by
L&P. You will be required to pay 1/22nd of the then current replacement cost of the part multiplied by the number of years past the third year from the Warranty
Commencement Date. This portion is calculated using the following formula: Cost of the part divided by 22 [being the number of years in years 4 to 25 inclusive], multiplied by the number of years you have owned the base since the end of the first 3 years. For example, if you make a claim for a part eligible for this warranty in the 5th year since the Warranty Commencement Date, you would be responsible for paying: $100 part cost divided by 22, multiplied by 2 = $9.09.
This warranty will be void if either the recommended weight restriction is not followed (refer to the advisory section of the Owner’s Manual) or if You sell or give or transfer the base to another person.
Any repairs to or replacement to Your adjustable base or its components under the terms of this limited warranty does not extend the applicable warranty from the Warranty
Commencement Date. This time limitation may not apply in some jurisdictions, including the Province of Quebec.
The decision to repair or to replace defective parts under this warranty shall be made, or cause to be made, by L&P at its option and in its sole discretion.
Continued on next page...
22
Performance Models Simplicity Owners Manual 99301470-b
1 YEAR, 3 YEAR AND 25 YEAR LIMITED WARRANTY
Repair or replacement shall be the sole remedy of the
Purchaser. There shall be no liability on the part of L&P for any special, indirect, incidental, or consequential damages or for any other damage, claim, or loss not expressly covered by the terms of this warranty.
This limited warranty does not include reimbursement for inconvenience, removal, installation, setup time, loss of use, shipping, or any other costs or expenses. L&P and its service technicians will not be responsible for moving furniture or any other items not attached to the adjustable base in order to perform service on the adjustable base.
It is the sole responsibility of You to provide adequate space and accessibility to the adjustable base. In the event that the technician is unable to perform service due to lack of accessibility, the service call will be billed to
You and the service will have to be rescheduled.
L&P makes no other warranty whatever, express or implied, and all implied warranties of merchantability and fitness for a particular purpose are disclaimed by L&P and excluded from this agreement.
Some American States do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to You.
This warranty gives You specific legal rights, and You may also have other rights, which may vary from jurisdiction to jurisdiction. This warranty is valid in all 50 American
States, the District of Columbia, Puerto Rico, and all 10
Provinces and 3 Territories of Canada.
For customer service under this limited warranty, give notice to L&P by mail, phone, email or online to the addresses set out below:
Leggett & Platt, Incorporated
PO Box 668
Lexington, North Carolina 27293
toll free phone: 1.800.888.3078
online: lpadjustablebases.com
email: [email protected]
PLEASE DO NOT CONTACT YOUR RETAIL DEALER
OR ANY OTHER SERVICE PERSONNEL
Performance Models Simplicity Owners Manual 99301470-b
23
Shkarko
Reklamë