Furuno VR-5000 Operator's Manual

Add to My manuals
2 Pages

advertisement

Furuno VR-5000 Operator's Manual | Manualzz

VR-5000 OPERATOR’S GUIDE

1. Recording

To start recording, press the AC breaker on the Power Distribution Unit (PDU) in the Data

Collecting Unit (DCU). Press the Battery breaker as well. When the DC power supply is connected to the VDR as an emergency source of power, press the DC breaker. The VDR records data automatically in both memory of the Data Recording Unit (DRU) and the removable hard disk (HD).

Data processor unit

Key (inside)

Breaker switches

(AC, DC and BATTERY from left)

Hard disk

(HD)

Lever

Status LEDs

Status LED (DCU OK)

(SYS1, 2, 3 from left)

Power-on indicators

Breakers on PDU in DCU

The LEDs on the PDU operate as follows.

LEDs Status Remarks of mains

DC Green Presence of DC power supply if connected

BATTERY Green Presence of DC power from reserve battery

(Blinking during charging)

DCU OK Green Normal operation of DCU processor (NG: Red)

SYS 1 to 3 Orange No error (Other colors: see error code list in the operator’s manual)

2. Stopping recording

Note that the recording is stopped in the following cases;

- During essential maintenance purposes whilst the vessel is in port.

- When the vessel is laid-up.

To stop recording, depress the BATTERY, DC and AC breaker switches in this order. DO NOT

turn off the system by the main breaker on the ship's switch panel while the AC breaker is on. If this is done, the system operates from the reserve battery.

3. Operation on Remote Alarm Panel (RAP)

To silence the alarm, press the ACK button. When the ERROR LED on the Remote Alarm

Panel is on, identify the error by checking the status LEDs on the PDU in the DCU, referring to the operator’s manual. The buttons on the remote alarm panel work as described in the figure below.

Dimmer Buzzer

LEDs from left

NORMAL (Green):

Must be ON.

ERROR (Red):

Lights when an error occurs.

SAVE (Yellow):

When stopping the data recording onto HD, this

LED starts blinking from

OFF state, then lights steadily.

Remote Alarm Panel (RAP)

4. If an Incident Occurs

Buttons from left

SAVE (w/ protective cover):

Stops recording onto HD only when an incident occurs.

ACK: Stops buzzer sound.

TEST: Used for testing.

1. Press the SAVE button (long press) on the RAP until the SAVE LED blinks.

After completing the save process, the buzzer on the RAP sounds and the SAVE LED stops blinking and lights. At this time, although recording to the HD is stopped in order to protect data in HD, recording at the DRU continues.

Note: Do not press the SAVE button except when an incident occurs.

2. Bring the HD with you when leaving the vessel if possible. Do not turn off the power.

1) Open the DCU with the key.

2) Open the front panel of the Data Processor Unit with the key (see previous page).

3) Turn the lever of HD outward and then turn the key fully counterclockwise.

4) Pull the lever to take out the HD.

Note: Rerecording to the HD is prevented in order to protect data. Follow the procedure below to replace it with a new HD if necessary.

1. Open the DCU with the key and turn off the three breaker switches.

2. Open the front panel of the Data Processor Unit with the key.

3. Turn the lever of HD outward and then turn the key fully counterclockwise.

4. Pull the lever to take out the HD and replace it with a new one.

5. Turn the key for HD fully clockwise.

6. Close the front panel of the Data Processor Unit with the key.

7. Turn on the three breaker switches. Confirm that the SAVE LED of RAP goes off.

8. Close the DCU with the key.

Note: The backup HD may only be replaced in the following situations:

1) When the equipment can be powered off (stopped recording). See previous page.

2) When completing the save process after an incident occurs.

P U B . N O . O S E - 4 4 1 8 0 - C 2

( 0 7 0 1 , T A T A ) V R - 5 0 0 0

advertisement

Key Features

  • Automatic data recording in DRU memory and removable HD
  • Remote Alarm Panel (RAP) for monitoring and controlling
  • Easy HD removal for data retrieval
  • Protection of HD data during incidents
  • Essential maintenance and lay-up recording stoppage
  • Emergency DC power supply for continuous recording
  • Status LEDs for system monitoring

Related manuals

Frequently Answers and Questions

How do I start recording data?
Press the AC, Battery, and DC breaker switches on the Power Distribution Unit (PDU) in the Data Collecting Unit (DCU).
How do I stop recording data?
Depress the BATTERY, DC, and AC breaker switches in that order.
What do the LEDs on the Remote Alarm Panel indicate?
The NORMAL LED must be ON, the SAVE LED blinks when data recording onto the HD is stopped due to an incident, and the ERROR LED lights when an error occurs.
How do I protect data on the HD during an incident?
Press the SAVE button on the RAP until the SAVE LED blinks.
How do I replace the HD?
Open the DCU, turn off the three breaker switches, open the Data Processor Unit, turn the HD lever outward, turn the key counterclockwise, pull the lever to remove the HD, replace it with a new one, and follow the steps in reverse order.
Download PDF