TimePlex Synchrony CX-1500, CX-1540 Cell Exchange User’s Guide
Reklāma
Reklāma
Synchrony
CX-1500/CX-1540
Cell Exchange
User’s Guide
MC17300
July 1998
TimePlex Group
Worldwide Headquarters
400 Chestnut Ridge Road
Woodcliff Lake, NJ 07675
USA
(888) 777-0929 • (201) 391-1111
Americas Division
400 Chestnut Ridge Road
Woodcliff Lake, NJ 07675
USA
(888) 777-0929
•
(201) 391-1111
CANADA
TimePlex Canada, Inc.
50 Acadia Ave., Suite 205
P.O. Box 25
Markham, ON
Canada L3R 0B3
(905) 947-1481
Americas Customer Support
16255 Bay Vista Drive
Clearwater, FL 34620
USA
(727) 530-9475
Timeplex Federal Systems, Inc.
12150 Monument Drive
Suite 750
Fairfax, VA 22033
USA
(703) 385-3366
Europe/Middle East/Africa
Division
Langley Business Centre
Station Road, Langley
Slough, Berkshire, SL3 8DT
United Kingdom
(44) 0 1753 601000
EUROPE/AFRICA DISTRIBUTORS
10 Rue de Genéve, Bte 17
B-1140 Brussels
Belgium
(32) 2 745.02.30
FRANCE
39 Avenue des Trois Peuples
F-78180 Montigny-le-Bretonneux
France
(33.1) 30.64.81.00
GERMANY
Edisonstrasse 11-13
D-60388 Frankfurt
Germany
(49) 610-973-8505
Far East Division
30th Floor, Windsor House
311 Gloucester Road
Causeway Bay
Hong Kong
(852) 2830 9889
Australia/New Zealand
Division
Level 21
1 York Street
Sydney, NSW 2000
Australia
(612) 9 247 1422
7/98
NO WARRANTIES ARE EXTENDED BY THIS DOCUMENT. The technical information in this document is proprietary to Timeplex, Inc. and the recipient has a personal, non-exclusive and non-transferable license to use this information solely with the use of Timeplex products. The only product warranties made by Timeplex, Inc., if any, are set forth in the agreed terms and conditions for purchase of a
Timeplex product. Timeplex, Inc. disclaims liability for any and all damages that may result from publication or use of this document and/or its contents except for infringement of third party copyright or misappropriation of third party trade secrets. No part of this document may be reproduced in any manner without the prior written consent of Timeplex, Inc.
U.S. GOVERNMENT RESTRICTED AND LIMITED RIGHTS
All software and related software documentation supplied by Timeplex, Inc. to the United States
Government are provided with Restricted Rights. Use, duplication, or disclosure by the Government is subject to restrictions as set forth in subparagraph (c)(1)(ii) of the Rights in Technical Data and Computer
Software clause at DFARS 252.227-7013 or subparagraph (c)(2) of the Commercial Computer Software–
Restricted Rights at CFR 52.227-19, as applicable.
All documentation, other than software documentation which are provided with Restricted Rights, are provided with Limited Rights. U.S. Government rights to use, duplicate, or disclose documentation, other than software documentation, are governed by the restrictions defined in paragraph (a)(15) of the Rights in Technical Data and Computer Software clause at DFARS 252.227-7013.
“DFARS” is the Department of Defense Supplement to the Federal Acquisition Regulation.
Contractor/manufacturer is Timeplex, Inc., 400 Chestnut Ridge Road, Woodcliff Lake, NJ 07675.
The information in this document is subject to change without notice. Revisions may be issued at such time as information changes.
VT100 is a registered trademark of Digital Equipment Corporation.
Windows is a registered trademark of Microsoft Corporation.
Timeplex and Synchrony are registered trademarks of Timeplex, Inc.
Express Routing, Express Switching, LINK2+, and LINK/100+ are trademarks of Timeplex, Inc.
ProComm is a registered trademark of Datastorm Technologies, Incorporated.
Intel is a registered trademark of Intel Corporation.
NOTICE
Telecommunications products must be installed and operated in compliance with the relevant
National Regulatory requirements summarized in the “REGULATORY” section of this manual. READ
IN FULL, PRIOR TO INSTALLATION, any product-specific National Regulatory requirements applicable to the country of installation.
©
1998 Timeplex, Inc.
ii
CXUG
7-31-98
CXUG
7-31-98
WARNING
VORSICHT
NO OPERATOR SERVICEABLE PARTS ARE
INSIDE THIS EQUIPMENT. SERVICE MUST BE
PERFORMED BY QUALIFIED SERVICE
PERSONNEL.
NICHT VOM BENUTZER REPARIERBARE TEILE IM
GEHÄUSE. BITTE WENDEN SIE SICH AN
QUALIFIZIERTES WARTUNGSPERSONAL.
ATTENTION CET APPAREIL NE CONTIENT AUCUN ELÉMENT
QUE L'UTILISATEUR PUISSE RÉPARER. CONFIER
LA MAINTENANCE À UN PERSONNEL TECHNIQUE
QUALIFIÉ.
WARNING: THIS EQUIPMENT MAY HAVE MORE THAN ONE
POWER SUPPLY CORD. DISCONNECT ALL
POWER SUPPLY CORDS BEFORE SERVICING TO
AVOID ELECTRICAL SHOCK.
VORSICHT: DIESES GERÄT HAT MEHERE NETZANSCHLÜßE.
ZUR WARTUNG ALLE NETZKABEL TRENNEN UM
ELEKTRISCHEN SCHLAG ZU VERHINDERN.
ATTENTION: CET APPAREIL COMPORT PLUS D'UN CORDON
D'ALIMENTATION AFIN DE PRÉVENIR LES CHOCS
ÉLECTRIQUES. DÉBRANCER TOUS LES
CORDONS D'ALIMENTATION AVANT LA
MAINTENANCE.
iii
About This Manual
This manual supports Release 2.1 of the Synchrony Cell Exchange system.
The Synchrony Cell Exchange CX1500/CX1540 User’s Guide is part of the Synchrony library.
The primary purpose of the Synchrony Cell Exchange CX1500/CX1540 User’s Guide is to assist in installation, initial configuration, and operation of a Cell Exchange system.
Timeplex, Inc.
recommends that users obtain formal training prior to using this product. This manual is intended to supplement–not replace–formal training.
Contact Educational Services at 1-800-356-8338 for information.
NOTES:
Throughout this manual the term “system” and the expression “Cell
Exchange system” are used to apply to both the CX-1500 and CX-
1540 Cell Exchange Models, collectively.
The term “module” is used throughout this manual to represent component cards that have specific application and have been designed for use in both the CX-1500 and CX-1540 systems.
Organization of This Manual
This manual describes the Synchrony Cell Exchange system. This covers the physical design, basic and expanded configurations, and the available modules to expand the system to meet the user’s parameters.
The organization of this information is described below.
Chapters 1 through 8
•
Chapter 1, Overview, provides a brief summary of ATM service, the CX-1500 and CX-1540 systems, common and interface modules, timing (or clocking), cooling and performance characteristics.
•
Chapter 2, Installation, provides procedures for installing the Cell Exchange systems.
•
Chapter 3, Modules, describes each of the interface modules that can be used in the Cell
Exchange systems depending on the needs of the users.
•
Chapter 4, Operation, describes the procedures to operate the Cell Exchange systems.
•
Chapter 5, Configuration, provides procedures for configuring the Cell Exchange systems to include all possible module applications.
iv
CXUG
7-31-98
•
Chapter 6, Troubleshooting, provides an overview of diagnostic procedures used to locate the cause of malfunctions in Cell Exchange applications.
•
Chapter 7, Replacement Procedures, provides step-by-step procedures for removing and replacing field replaceable units.
Appendixes
•
Appendix A, ATM Overview, describes basic ATM concepts.
•
Appendix B, Cable Diagrams, provides an index of Cell Exchange cables and cable wiring diagrams.
•
Appendix C, Cable Applications, includes diagrams showing the types and applications of cables used in a Cell Exchange system.
•
Appendix D, Field-Replaceable Units, provides an index of Cell Exchange field replaceable items.
Service
For service in the U.S. and Canada, contact Customer Support at 1-800-237-6670.
For service outside the U.S. and Canada, contact your local sales representative.
Information required for service is:
Model No. ________________________ Serial No. ______________________________
Warnings, Precautions, and Notes
Be sure that you understand all directions, warnings, and limitations before using this product. In this manual:
•
WARNINGS present information or describe conditions which if not observed could result in injury.
•
PRECAUTIONS reflect conditions which could cause product damage or data loss.
•
NOTES describe limitations on the use of the equipment or procedure.
CXUG
7-31-98 v
If Product Is Received Damaged
Forward an immediate request to the delivering carrier to perform an inspection and prepare a damage report. SAVE container and packing material until contents are verified.
Concurrently, report the nature and extent of damage to Customer Support so that action can be initiated to repair or replace damaged items or instructions issued for returning items.
The responsibility of the manufacturer ends with delivery to the first carrier. ALL CLAIMS for loss, damage, or nondelivery must be made against the delivering carrier WITHIN 10 DAYS OF
RECEIPT of shipment.
To Return Product
Please obtain instructions from Customer Support before returning any item(s). Report the fault or deficiency along with the model, type, and serial number of the item(s) to Customer Support. Upon receipt of this information, Customer Support will provide service instructions or a Return
Authorization Number and other shipping information. All items returned under this warranty must be sent to the manufacturer with charges prepaid.
vi
CXUG
7-31-98
Contents
CXUG
7-31-98
Overview ......................................................................................................1-1
THE CX-1500/CX-1540 CELL EXCHANGE SYSTEMS .................................................. 1-1
Modules and Services ......................................................................................................... 1-2
EQUIPMENT DESCRIPTION ........................................................................................... 1-4
CX-1500............................................................................................................................. 1-4
CX-1540............................................................................................................................. 1-5
Power Distribution.............................................................................................................. 1-6
Indicators............................................................................................................................ 1-6
CPU Module....................................................................................................................... 1-6
Power Supply Module......................................................................................................... 1-6
Station Clock Module ......................................................................................................... 1-7
Interface Modules ............................................................................................................... 1-7
TIMING ............................................................................................................................. 1-7
System Timing.................................................................................................................... 1-7
Data Bus Timing................................................................................................................. 1-9
Channel/Port Timing........................................................................................................... 1-9
External Timing................................................................................................................ 1-10
SYSTEM COOLING........................................................................................................ 1-11
PERFORMANCE CHARACTERISTICS ......................................................................... 1-11
Installation ...................................................................................................2-1
SITE PREPARATION........................................................................................................ 2-1
EQUIPMENT INSTALLATION ........................................................................................ 2-1
Unpacking .......................................................................................................................... 2-1
Required Tools and Equipment ........................................................................................... 2-1
Chassis Installation Procedures ........................................................................................... 2-1
Grounding Requirements .................................................................................................... 2-2
Power Connections ............................................................................................................. 2-2
Module Installation Procedures ........................................................................................... 2-3
Modules .......................................................................................................3-1
SUMMARY OF MODULES .............................................................................................. 3-1
CPU MODULE .................................................................................................................. 3-3
Overview ............................................................................................................................ 3-3
Indicators............................................................................................................................ 3-5
Pinouts................................................................................................................................ 3-5
AC POWER SUPPLY MODULE ....................................................................................... 3-6
STATION CLOCK MODULE (SCM)................................................................................ 3-8
Overview ............................................................................................................................ 3-8
Indicators............................................................................................................................ 3-9
Pinouts................................................................................................................................ 3-9
DUAL T-1 CELL INTERFACE MODULE (T1C)............................................................ 3-10
Overview .......................................................................................................................... 3-10
Specifications ................................................................................................................... 3-11 vii
viii
Indicators.......................................................................................................................... 3-12
Pinouts.............................................................................................................................. 3-12
OC-3 CELL INTERFACE MODULE (OC3) .................................................................... 3-13
Overview .......................................................................................................................... 3-13
Specifications ................................................................................................................... 3-16
Indicators.......................................................................................................................... 3-17
Pinouts.............................................................................................................................. 3-17
DUAL SYNCHRONOUS CELL INTERFACE MODULE(DSC) ..................................... 3-18
Overview .......................................................................................................................... 3-18
Specifications ................................................................................................................... 3-19
Indicators.......................................................................................................................... 3-20
Pinouts.............................................................................................................................. 3-20
DS-3 CELL INTERFACE MODULE (DS3) ..................................................................... 3-22
Overview .......................................................................................................................... 3-22
Specifications ................................................................................................................... 3-23
Indicators.......................................................................................................................... 3-24
Pinouts.............................................................................................................................. 3-24
STRUCTURED T-1 LEGACY MODULE (STL) ............................................................. 3-25
Overview .......................................................................................................................... 3-25
STL Operation .................................................................................................................. 3-27
Specifications ................................................................................................................... 3-30
Indicators.......................................................................................................................... 3-30
Pinouts.............................................................................................................................. 3-31
SYNCHRONOUS LEGACY INTERFACE MODULES (DSL)........................................ 3-32
Overview .......................................................................................................................... 3-32
Specifications ................................................................................................................... 3-34
Indicators.......................................................................................................................... 3-35
Pinouts.............................................................................................................................. 3-35
HIGH-SPEED SYNCHRONOUS LEGACY INTERFACE MODULE (HSL)................... 3-36
Overview .......................................................................................................................... 3-36
Specifications ................................................................................................................... 3-38
Indicators.......................................................................................................................... 3-39
Pinouts.............................................................................................................................. 3-39
Operation .....................................................................................................4-1
INITIAL STARTUP ........................................................................................................... 4-1
Local Management Station.................................................................................................. 4-1
Initial Logon ....................................................................................................................... 4-3
MENU OPERATION ......................................................................................................... 4-4
Menu Selection ................................................................................................................... 4-5
Command Operation........................................................................................................... 4-6
MAIN MENU..................................................................................................................... 4-7
Configure Menu.................................................................................................................. 4-7
View Menu ......................................................................................................................... 4-9
Diagnostics Menu ............................................................................................................. 4-10
ALARMS ......................................................................................................................... 4-13
MODULE STATISTICS .................................................................................................. 4-13
Dual T-1 Cell Interface Module......................................................................................... 4-15
OC-3 Cell Interface Module.............................................................................................. 4-17
Dual Synchronous Cell Interface Module .......................................................................... 4-19
CXUG
7-31-98
CXUG
7-31-98
DS-3 Cell Interface Module .............................................................................................. 4-21
Structured T-1 Legacy Module.......................................................................................... 4-23
Synchronous Legacy Interface Module.............................................................................. 4-25
High-Speed Synchronous Legacy Interface Module .......................................................... 4-27
Configuration ..............................................................................................5-1
SETTING LOCATION NAME .......................................................................................... 5-1
CONFIGURING PHYSICAL INTERFACES ..................................................................... 5-2
SETTING SYSTEM TIMING ............................................................................................ 5-6
SOFTWARE VERSIONS................................................................................................... 5-6
CONFIGURING INTERFACE CONNECTIONS............................................................... 5-8
STATION CLOCK MODULE CONFIGURATION ......................................................... 5-11
Configuring Interfaces ...................................................................................................... 5-11
DUAL T-1 CELL INTERFACE MODULE CONFIGURATION...................................... 5-12
Configuring Interfaces ...................................................................................................... 5-12
Configuring Connections .................................................................................................. 5-13
OC-3 CELL INTERFACE MODULE CONFIGURATION .............................................. 5-14
Configuring Interfaces ...................................................................................................... 5-14
Configuring Connections .................................................................................................. 5-15
DUAL SYNCHRONOUS CELL INTERFACE MODULE CONFIGURATION............... 5-16
Configuring Interfaces ...................................................................................................... 5-16
Configuring Connections .................................................................................................. 5-17
DS-3 CELL INTERFACE MODULE CONFIGURATION............................................... 5-18
Configuring Interfaces ...................................................................................................... 5-18
Configuring Connections .................................................................................................. 5-19
STRUCTURED T-1 LEGACY MODULE CONFIGURATION ....................................... 5-20
Configuring STL Interfaces............................................................................................... 5-20
Configuring Connections .................................................................................................. 5-22
SYNCHRONOUS LEGACY INTERFACE MODULE CONFIGURATION .................... 5-24
Configuring Interfaces ...................................................................................................... 5-24
Configuring Connections .................................................................................................. 5-25
HIGH-SPEED SYNCHRONOUS LEGACY INTERFACE MODULE
CONFIGURATION..................................................................................................... 5-26
Configuring Interfaces ...................................................................................................... 5-26
Configuring Connections .................................................................................................. 5-27
Troubleshooting..........................................................................................6-1
GENERAL TROUBLESHOOTING PROCEDURES ......................................................... 6-1
Power Supply Module......................................................................................................... 6-1
CPU Module....................................................................................................................... 6-1
Other Modules .................................................................................................................... 6-2
ALARMS ........................................................................................................................... 6-2
USER-INITIATED TESTS................................................................................................. 6-6
Replacement Procedures...........................................................................7-1
ELECTROSTATIC DISCHARGE (ESD) ANTI-STATIC PROCEDURE........................... 7-1
REMOVING AND REPLACING CHASSIS ...................................................................... 7-1
REMOVING AND REPLACING MODULES ................................................................... 7-2
Model CX-1500 Power Supply Module............................................................................... 7-3 ix
CPU Module....................................................................................................................... 7-3
Other Modules .................................................................................................................... 7-4
FUSE REPLACEMENT ..................................................................................................... 7-5
Asynchronous Transfer Mode.................................................................. A-1
ATM NETWORKS ........................................................................................................... A-1
ATM CELL ....................................................................................................................... A-2
ATM REFERENCE MODEL ............................................................................................ A-3
Physical Layer ................................................................................................................... A-4
ATM Layer........................................................................................................................ A-4
ATM Adaptation Layer...................................................................................................... A-5
QUALITY OF SERVICE .................................................................................................. A-5
ATM REFERENCES......................................................................................................... A-6
Cable Diagrams.......................................................................................... B-1
Cable Applications .................................................................................... C-1
Field-Replaceable Units ............................................................................ D-1
Index
Regulatory
x
CXUG
7-31-98
Figures
Figure 1-1. Cell Exchange System Architecture ..................................................................................... 1-2
Figure 1-2. Cell Exchange System Interfaces ......................................................................................... 1-3
Figure 1-3. CX-1500 Cell Exchange System .......................................................................................... 1-4
Figure 1-4. CX-1540 Cell Exchange System .......................................................................................... 1-5
Figure 1-5. System Timing Diagram ...................................................................................................... 1-8
Figure 1-6. Cell Exchange with Stacking Fan Unit ............................................................................... 1-11
Figure 2-1. CX-1500 AC Power Connector Module (Rear Chassis) ........................................................ 2-2
Figure 2-2. CX-1540 AC Power Connector Module (Rear Chassis) ........................................................ 2-3
Figure 3-1. Front Panel of CPU Module (CPU) ...................................................................................... 3-3
Figure 3-2. CPU Module Functional Diagram ........................................................................................ 3-4
Figure 3-3. DB-9M Connector ............................................................................................................... 3-5
Figure 3-4. AC Power Supply Module Functional Diagram.................................................................... 3-6
Figure 3-5. Station Clock Module (SCM)............................................................................................... 3-8
Figure 3-6. HDB-26F (DCE) Pin Location ............................................................................................. 3-9
Figure 3-7. Dual T1 Cell Interface Module (T1C) ................................................................................ 3-10
Figure 3-8. Dual T1 Cell Interface Module Functional Diagram ........................................................... 3-11
Figure 3-9. Pin Location ...................................................................................................................... 3-12
Figure 3-10. OC-3 Cell Interface Module (OC3) .................................................................................. 3-14
Figure 3-11. OC-3 Cell Interface Module Functional Diagram ............................................................. 3-15
Figure 3-12. SC Connector .................................................................................................................. 3-17
Figure 3-13. Dual Synchronous Cell Interface Module (DSC) .............................................................. 3-18
Figure 3-14. Dual Channel Synchronous Cell Interface Module Functional Diagram ............................ 3-19
Figure 3-15. HDB-26F (DTE) Pin Location ......................................................................................... 3-20
Figure 3-16. DS-3 Cell Interface Module (DS3) ................................................................................... 3-22
Figure 3-17. DS-3 Cell Interface Module Functional Diagram.............................................................. 3-23
Figure 3-18. BNC Pin Location ........................................................................................................... 3-24
Figure 3-19. Structured T1 Legacy Interface Module (STL) ................................................................. 3-25
Figure 3-20. T1 Mapping..................................................................................................................... 3-26
Figure 3-21. STL to VPI/VCI Connections .......................................................................................... 3-26
Figure 3-22. Channel Mapping ............................................................................................................ 3-27
Figure 3-23. Trunk Conditioning ......................................................................................................... 3-28
Figure 3-24. Another Example of Trunk Conditioning ......................................................................... 3-29
Figure 3-25. Pinouts ............................................................................................................................ 3-31
Figure 3-26. Synchronous Legacy Interface Modules (DSL)................................................................. 3-32
Figure 3-27. Synchronous Legacy Interface Module (DSL) Functional Diagram................................... 3-34
Figure 3-28. HDB-26F (DCE) Pin Location ......................................................................................... 3-35
Figure 3-29. High Speed Synchronous Legacy Interface Module (HSL) ............................................... 3-36
Figure 3-30. High Speed Synchronous Legacy Interface Module Functional Diagram .......................... 3-38
Figure 3-31. HDB-26F (DCE) Pin Location ......................................................................................... 3-39
Figure 4-1. Local Cell Exchange—VT100 Connection........................................................................... 4-1
Figure 4-2. Logon Screen ...................................................................................................................... 4-3
Figure 4-3. Password Menu ................................................................................................................... 4-4
Figure 4-4. Main Menu Screen .............................................................................................................. 4-5
Figure 4-5. Main Menu Screen .............................................................................................................. 4-7
Figure 4-6. Date/Time Window from Configure Menu........................................................................... 4-8
Figure 4-7. System Reset Window from Configure Menu....................................................................... 4-9
Figure 4-8. Module Status Window from View Menu ............................................................................ 4-9
Figure 4-9. Admin Info Window from View Menu .............................................................................. 4-10
Figure 4-10. Timing Source Window from View Menu........................................................................ 4-10
CXUG
7-31-98 xi
Figure 4-11. Initialize Database Window from Diagnostics Menu ........................................................ 4-11
Figure 4-12. Save Database Window from Diagnostics menu............................................................... 4-11
Figure 4-13. Restore Database Window from Diagnostics Menu .......................................................... 4-12
Figure 4-14. Module Status Window.................................................................................................... 4-13
Figure 4-15. Logical Interface Status Window...................................................................................... 4-14
Figure 4-16. Specific Interface Window............................................................................................... 4-14
Figure 4-17. Logical Interface Status Window—Dual T1 Cell.............................................................. 4-15
Figure 4-18. Specific Interface Window—Dual T1 Cell ....................................................................... 4-16
Figure 4-19. Interface Statistics Window—Dual T1 Cell ...................................................................... 4-16
Figure 4-20. Logical Interface Status Window—OC3 Cell ................................................................... 4-17
Figure 4-21. Specific Interface Window—OC3 Cell............................................................................. 4-18
Figure 4-22. Interface Statistics Window—OC3 Cell ........................................................................... 4-18
Figure 4-23. Logical Interface Status Window—Dual Sync Cell .......................................................... 4-19
Figure 4-24. Specific Interface Window—Dual Sync Cell.................................................................... 4-20
Figure 4-25. Interface Statistics Window—Dual Sync Cell................................................................... 4-20
Figure 4-26. Logical Interface Status Window—DS3 ........................................................................... 4-21
Figure 4-27. Specific Interface Window—DS3 .................................................................................... 4-22
Figure 4-28. Interface Statistics Window—DS3 ................................................................................... 4-22
Figure 4-29. Logical Interface Status Window—STL ........................................................................... 4-23
Figure 4-30. Specific Interface Window—Structured T1 ...................................................................... 4-24
Figure 4-31. Interface Statistics Window—Structured T1..................................................................... 4-24
Figure 4-32. Logical Interface Status Window—Dual Sync Leg ........................................................... 4-25
Figure 4-33. Specific Interface Window—Dual Sync Leg .................................................................... 4-26
Figure 4-34. Interface Statistics Window—Dual Sync Leg ................................................................... 4-26
Figure 4-35. Logical Interface Status Window...................................................................................... 4-27
Figure 4-36. Specific Interface Window—High-Speed Sync Leg.......................................................... 4-28
Figure 4-37. Interface Statistics Window—High-Speed Sync Leg ........................................................ 4-28
Figure 5-1. Configure Menu – Location Name ....................................................................................... 5-1
Figure 5-2. Location Name Screen......................................................................................................... 5-2
Figure 5-3. Configure Menu – Interface ................................................................................................. 5-2
Figure 5-4. Interface Menu .................................................................................................................... 5-3
Figure 5-5. Entering Interface Information ............................................................................................. 5-3
Figure 5-6. Detailed Interface Configuration (Dual T1 Cell Interface) .................................................... 5-4
Figure 5-7. System Timing Window ...................................................................................................... 5-6
Figure 5-8. Software Version Command ................................................................................................ 5-7
Figure 5-9. Software Version Selection Screen....................................................................................... 5-7
Figure 5-10. Connection Management Window...................................................................................... 5-8
Figure 5-11. Configuration Management Mapping Menu ....................................................................... 5-9
Figure 5-12. Interface Configuration Window—Station Clock Module................................................. 5-11
Figure 5-13. Interface Configuration Window – Dual T-1 Cell ............................................................. 5-12
Figure 5-14. Connection Management Window.................................................................................... 5-13
Figure 5-15. Interface Configuration Window – OC3 Cell.................................................................... 5-14
Figure 5-16. Configuration Management Mapping Window – OC3 Cell............................................... 5-15
Figure 5-17. Interface Configuration Window – Dual Sync Cell ........................................................... 5-16
Figure 5-18. Configuration Management Mapping Window – Dual Sync Cell ...................................... 5-17
Figure 5-19. Interface Configuration Window – DS3 ........................................................................... 5-18
Figure 5-20. Configuration Management Mapping Window – DS3 ...................................................... 5-19
Figure 5-21. Interface Configuration Window – Structured T-1............................................................ 5-20
Figure 5-22. Connection Management Mapping Window – Structured T1 ............................................ 5-22
Figure 5-23. Connection Management Mapping Window – Structured T1 ............................................ 5-23
Figure 5-24. Interface Configuration Window – Dual Sync Leg............................................................ 5-24
Figure 5-25. Connection Management Mapping Window – Dual Sync Leg .......................................... 5-25
Figure 5-26. Interface Configuration Window – High-Speed Leg ......................................................... 5-26
Figure 5-27. Connection Management Mapping Window – High-Speed Leg ........................................ 5-27 xii
CXUG
7-31-98
Figure 6-1. Alarm Log Window............................................................................................................. 6-5
Figure 6-2. Loopback Window from Diagnostics Menu ......................................................................... 6-6
Figure 6-3. Loopback Data Flow............................................................................................................ 6-7
Figure 7-1. Removal of a Cell Exchange System Module (Power Supply) .............................................. 7-2
Figure 7-2. Rear Panel AC Connector with Fuse Well Exposed .............................................................. 7-6
Figure A-1. ATM Cell Structure ............................................................................................................A-3
Figure A-2. ATM Reference Model .......................................................................................................A-4
Figure A-3. Service Classification for AAL ...........................................................................................A-5
Figure B-1. CPU Craft Interface to VT100 Terminal ..............................................................................B-4
Figure B-2. CPU Craft Interface to Modem (610133-X).........................................................................B-5
Figure B-3. DSC/DSL/HSL/SCM Modules to RS-530 (V.11) (613008-X) (Sheet 1 of 2) ........................B-6
Figure B-3. DSC/DSL/HSL/SCM Modules to RS-530 (V.11) (613009-X) (Sheet 2)...............................B-7
Figure B-4. DSL/HSL Modules (DCE) to LINK/2+ or entréeLINK+ ILC
Module (613004-X) ......................................................................................................................B-8
Figure B-5. DSL/HSL/SCM Modules to RS-449 (613005-X) (Sheet 1 of 2) ...........................................B-9
Figure B-5. DSL/HSL/SCM Modules to RS-449 (613006-X) (Sheet 2) ................................................ B-10
Figure B-6. DSL/HSL/SCM Module to V.35 (613003-X) (Sheet 1 of 2) ............................................... B-11
Figure B-6. DSL/HSL/SCM Module to V.35 (613007-X) (Sheet 2)...................................................... B-12
Figure B-7. STL Module to LINK/2+ BFM/BIM.1 Modules, LINK 100/+ DLI.1
Module, entréeLINK+ CSU Module, or ST D Panel-4/PRI (T1M/E1M); T1C to
CSU/Smart Jack (Straight) (610127-X) ....................................................................................... B-13
Figure B-8. T1C to CSU/Smart Jack (Crossover) (610126-X) .............................................................. B-13
Figure B-9. STL Module to ST D Panel-4/PRI (T1M/E1M) Via BIM/PBX Cable, T1C to
CSU/Smart Jack (Straight) Via DSX-1/CSU Cable (61362)......................................................... B-14
Figure B-10. STL (Via BADP Cable) to ST D Panel-4/DSX-1 (61359) ................................................ B-14
Figure B-11. T1C (Via BADP Cable) to CSU/Smart Jack (Crossover) (61385)..................................... B-15
Figure B-12. DS-3 Module to DS3 (45 Mbps) Service (120405-X)....................................................... B-15
Figure B-13. OC-3 Module to 155 Mbps (SONET) (Multimode Fiber) (FOXN0004) ........................... B-15
Figure B-14. OC-3 Module to 155 Mbps (SONET) (Single Mode Fiber) (FOXN0005)......................... B-16
Figure C-1. CPU Module Cabling..........................................................................................................C-1
Figure C-2. SCM Module Cabling .........................................................................................................C-1
Figure C-3. DSL, HSL Module Cabling .................................................................................................C-2
Figure C-4. T1C Module Cabling ..........................................................................................................C-3
Figure C-5. STL Module Cabling ..........................................................................................................C-3
Figure C-6. DS-3 Module Cabling .........................................................................................................C-4
Figure C-7. DSC Module Cabling..........................................................................................................C-4
Figure C-8. OC3 Module Cabling ..........................................................................................................C-5
Tables
Table 1-1. Cell Exchange System Modules ............................................................................................ 1-3
Table 1-2. Physical, Electrical and Environmental Characteristics ........................................................ 1-12
Table 3-1. Module Summary ................................................................................................................. 3-1
Table 6-1. Alarm Messages ................................................................................................................... 6-2
Table B-1. Cable Applicability Matrix ...................................................................................................B-1
Table B-2. Cable Index..........................................................................................................................B-2
CXUG
7-31-98 xiii
Table D-1. CX-1500/CX-1540 Field-Replaceable Units.........................................................................D-1
Table D-2. Cables..................................................................................................................................D-2 xiv
CXUG
7-31-98
Chapter
1
Overview
Asynchronous Transfer Mode (ATM) networking is a technology that provides high bandwidth, low delay, packet-like switching and multiplexing techniques. Usable capacity is segmented into
53-byte, fixed-size cells, consisting of header and information fields, allocated to services on demand. Data is sent at irregular intervals, depending on networking availability, and no synchronizing or timing signals are required.
ATM technology was first used mostly in local area networks (LANs) but is increasingly being deployed for applications in wide area networks (WANs) and for applications involving both private and public network operations within the enterprise. ATM is a technology-enabling infrastructure that provides a global networking platform from which to connect all forms of communications applications. See Appendix A for a more detailed discussion of ATM technology.
The new Cell Exchange ATM products (CX-1500 and CX-1540) provide a flexible, modular, scaleable and cost effective “multi-access” solutions to WAN connectivity for emerging ATM networks. Multi-access means that these products allow users to transition into the new ATM technology at their own pace, while preserving their investment in the existing application infrastructure. These Cell Exchange products provide the user with an ATM Cell platform that serves on the “network edge” to multiplex and concentrate cell bearing (ATM), Frame Relay and legacy traffic (IP, Ethernet, TDM, asynchronous, bi-synchronous, SNA). These two systems are ideal for the wide range of ATM applications because of their flexible architecture and diversified interface designs. In addition, powerful ATM service capabilities result with maximum network efficiency when full traffic management and “Any-to-Any” connectivity are combined in their operation.
The CX-1500/CX-1540 Cell Exchange Systems
The CX-1500/CX-1540 Cell Exchange systems provide a versatile, scaleable, secure, and cost effective ATM cell platform. The Cell Exchange systems provide for expansion of today’s totally ubiquitous ATM networking concept by using ATM technology at lower bit rates, while at the same time continuing to make use of existing equipment.
The Cell Exchange system is designed on a modular hierarchy of functionality that allows the user to add features and functionality on a ‘need only’ basis. Thus, the user has the freedom to ‘size’ the equipment to the requirements of the application. The architecture of the Cell Exchange system is shown in Figure 1-1.
CXUG
7-31-98
1-1
Power
Supply
Cells
Cell Bearing
Interface Module
Cells
Cell Bearing
Interface Module
Cells
Cell Bearing
Interface Module
Cell Buss
Cell Bearing
Interface Module
Cells
Non Cell Bearing
Interface Module
Data
Non Cell Bearing
Interface Module
Data
Non Cell Bearing
Interface Module
Data
CPU
Figure 1-1. Cell Exchange System Architecture
The Cell Exchange system is a modular and scaleable ATM cell multiplexer that operates by using an ATM Cell Bus architecture. The system is physically constructed and integrated into a card frame sub-chassis. The Cell Exchange system comes standard with a shelf, power supply module and CPU module. Other modules can be integrated into the systems. The user has a variety of modules to choose from. Once a Cell Exchange system is populated with the modules chosen by the user for a particular application, all communications between modules is through the ATM Cell
Bus located on the backplane. The Cell Exchange uses a passive backplane design that includes the
ATM cell bus and dual power and ground tracks.
Modules and Services
The Cell Exchange system extends ATM networks to sites and applications that do not support native ATM interfaces.
*
This is accomplished through the use of various Interface Modules. A typical example is illustrated in Figure 1-2.
*
Non-ATM protocols are referred to as legacy systems in this manual.
1-2
CXUG
7-31-98
CXUG
7-31-98
Cell
Networks or
Applications
Legacy
CPE or
Networks
Protocols
A T M
Legacy
Cell Bearing
Interface
Modules
Cell
Bearing
Cell
Bearing
Cell
Bearing
Cell
Bearing
Cell Buss
(800 Mbps)
Power
Supply 1
Power
Supply 2
Cell Bearing
Interface
Modules
Non Cell
Bearing
Non Cell
Bearing
Non Cell
Bearing
Non Cell
Bearing
CPU 1
CPU 2
Figure 1-2. Cell Exchange System Interfaces
Table 1-1 shows the modules that are currently available for use with the Cell Exchange system.
Table 1-1. Cell Exchange System Modules
Type Ports Maximum Rate
CPU Module
Station Clock Module
Common System Modules
—
—
—
—
T-1
OC-3
Dual Synchronous (DSC)
DS-3
Cell Bearing Interface Modules
2
1
2
1
1.544 Mbps
155 Mbps
20 Mbps
45 Mbps
Structured T-1
Non-Cell Bearing Interface Modules
4 1.544 Mbps
Hub Router
Low Speed Asynchronous
8 RJ45 + 1 BNC
8
25 Mbps
19.2 Kbps
1-3
Table 1-1. Cell Exchange System Modules (Cont’d)
Type Ports Maximum Rate
Structured E1
Non-Cell Bearing Interface Modules (Cont’d)
Synchronous (Dual)
High Speed Synchronous
4
1
4 or 8
128 Kbps – 2.048 Mbps
50 Mbps
2.048 Mbps
Equipment Description
The Cell Exchange system is available in two physical modular designs that can integrate with a variety of ATM interface modules to provide the versatility and scalability needed to accommodate the rapidly growing ATM market, today and in the future. The CX-1500 system has a 15-slot chassis and the CX-1540 system a 4-slot chassis. Both chassis accommodate the same modules and come with a full complement of ‘common functionality’ modules, which are those that are needed to provide basic unit operation. These common modules are the CPU, Power Supply and
Station Clock modules. The CX-1500 comes standard with a chassis, passive backplane, power supply module(s) and operates from a standard AC source. For this system, the power supply module may be configured redundantly to further increase operational reliability. The CX-1540 does not have resources for a redundant Power Supply Module.
CX-1500
The CX-1500 is based on a passive backplane design, which allows all modules to be inserted from the front. The chassis has slots for 16 modules (including the CPU), plus two slots for power supply modules. It is designed for easy rack mounting in a standard 19-inch rack, but because it is fully enclosed, it may also be used in a desktop environment. Figure 1-3 shows a front-panel view of the CX-1500 system with redundant Power Supply Modules.
CX-1500
CX-1500
AC POWER SUPPLY
AC POWER SUPPLY
T1 C
T1 C
T1 C
T1 C
OC3
OC3
OC3
CPU
DSC
SCM
DS3
DSL
STL
HSL
DSC
Figure 1-3. CX-1500 Cell Exchange System
1-4
CXUG
7-31-98
Chassis Specifications
Size: 5.25 inches high, 19 inches wide, 13 inches deep
Input Power: 90 to 230 VAC, 47 to 63 Hz, 2.0 amps
The Cell Exchange system chassis are based on a passive backplane design, which allows all modules to be inserted from the front. The power supply slot(s) is located in the left-most part of the chassis. In a chassis designed to accommodate more than one power supply module, a single module may be installed in either slot. The remaining slots may be populated with any type module. The CPU Module must be installed in slot 8 and the remaining slots be populated from the center outward.
Except for the Power Supply module, all Cell Exchange modules are designed in two sections: the
ATM Cell Bus control section, containing the Microprocessor and memory; and the module functionality section, which contains the components needed to perform the module’s unique function. All interface modules (exclusive of the CPU Module) have an identical ATM Cell Bus,
Microprocessor, and memory sections. For additional information on individual modules, see the
Chapter 3, “Modules.”
CX-1540
The CX-1540 is also based on a passive backplane design, which allows all modules to be inserted from the front. It has slots for 4 modules (including the CPU). The CPU must not be installed in
slot 1. The CX-1540 may be rack mounted, used on a desktop or, with optional hardware, wall
mounted. A typical front panel view of the CX-1540 is shown in Figure 1-4.
1
2
3
4
Synchrony
Cell Exchange
CX-1540
POWER
Figure 1-4. CX-1540 Cell Exchange System
Chassis Specifications
Size: 1.75 inches high, 19 inches wide, 13 inches deep
Input Power: 90 to 230 VAC, 47 to 63 Hz, 0.8 amps
CXUG
7-31-98
1-5
Power Distribution
Power distribution within the Cell Exchange 1500 systems is relatively simple. Standard AC power
(90 to 230 VAC, 47 to 63 Hz) is received at the backplane of the chassis and transferred via the power connector interface to the Power Supply Module. The Power Supply Module converts the
AC input to +5 VDC, which is then sent to a voltage regulator and the backplane bus.
Indicators
All indicators are located on the front panel of each module. Indicators for the various modules are described in the appropriate subsections in Chapter 3, “Modules.”
CPU Module
The CPU Module is designed around a Motorola 68340 microprocessor, and is used to control, configure, collect statistics, and provide all general management functionality within the unit. The
CPU module also provides master timing for the cell bus.
The CPU Module provides all configuration, control, and management functions for the Cell
Exchange systems from a local craft interface, remote dial-up modem management feature, or a
Simple Network Management Protocol (SNMP) interface. The CPU module controls all microprocessors/controllers on other Modules located in the same chassis, using the ATM bus message formatting structure. The CPU module (ATM bus) is also responsible for ATM Q.2931
signaling between the Cell Exchange CX-1500 and local/remote ATM switches.
Power Supply Module
The CX-1500 chassis may be equipped with one or two AC Power Supply Modules depending upon the degree of reliability the user is striving for. One Power Supply Module handles the full power load required for the number of interface modules placed in the chassis, with a reserve capacity of 40% above the maximum load capability. The Power Supply Modules feature a “solid state” switcher design. If two modules are installed, the modules are coupled to supply redundant power to the bus. The Power Supply Modules are designed to allow removal and replacement into a working unit without affecting active operational traffic (hot swap). Each Power Supply Module has its own power connector and cord.
The CX-1540 is equipped with a single AC Power Supply Module that is integrated with the chassis.
1-6
CXUG
7-31-98
Station Clock Module
The Station Clock (SCM) Interface Module allows the user to input and propagate an external clock source into the CX-1500 to be used as the internal reference clock for the unit. The SCM requires a balanced electrical input signal. The clock rate may be selected at a rate from 8 kHz to
50 MHz in 8 kHz steps.
Interface Modules
The Interface Modules are part of a broad group of modules that have been developed for the Cell
Exchange systems. Each Interface Module provides a specific service, as described in Chapter 3,
“Modules.”
Timing
The following describes the various timing systems and their functions that are resident in the
Synchrony Cell Exchange system. These timing systems are used specifically in ATM networks to support AAL1 (CBR) circuit emulation type traffic. There are four major timing systems in the
Cell Exchange system. These are:
•
System Timing
•
Data Bus Timing
•
Channel/Port Timing
•
External Timing
System Timing
System Timing is the term that is used when selecting a 'single' timing source to be used as the
Reference Timing Source by the Cell Exchange system. Only one timing source may be selected at a time. The Cell Exchange systems have the capability to select a pre-determined timing source that can be used by the rest of the Channel/Port Modules as a reference clock source. In Figure 1-5 the timing signal that may be chosen as the timing reference source is labeled REF/I (note that all of the REF/I lines are tri-stated for selection purposes which are microprocessor controlled).
Located on the same Figure, the timing signal that may be used as the timing reference is labeled
REF/O.
CXUG
7-31-98
1-7
1-8
OC3
S
T
Ref/ I
S
On Board
Clock
TX
RX
ST
SD
RT
R D
TT
TT
DSL/QSL
DIV
T
Ref/ I
s
DSC
S
FIFO
PLL
FIFO
P
L
L
S
S
PLL
Adaptive
Adjustment
(DCE)
Ref/ O
Int
Int
Ref/O
ST
SD
RT
R D
ST
RT
R D
TT
SD
FIFO
S T
R ef/ I
FIFO
HSL
S
P
L
L
FIFO
DIV
P
L
L
Adaptive
Adjustment
S
(DTE)
Ref/O
Int
T
R ef/ I
S
FI FO
(DCE)
DS3
On Board
Clock
S
TX
RX
CPU
Ref/ I
Internal
Clock
Ref/O
S
Clock Fail
Sys tem
Timing
Clock
Div
Logic
SCM
T
Ref /I
HRIM
LSAL
DIV
A
SY
NCH
R
O
N
OUS
ASY
N
C
H
RON
OUS
I N
TX
T1C
S
P
L
L
S
RX
On Board
Clock
Ref/O
Int
T
R ef/ I
Ref/O
STL
On Board
Clock
Int
Ref/ I
T
S
P
L
L
S TX
RX
Ref/I = In
Ref/O
= Out
Int = Internal
S
= Selector
T
= Tri-state
Figure 1-5. System Timing Diagram
CXUG
7-31-98
Data Bus Timing
A 25 MHz high-speed clock resident on the CPU module provides the Data Bus timing. Its primary use is to transfer ATM Cell traffic to and from installed modules in the Cell Exchange system chassis. Bus timing is only used on the bus; it is not used for any other purpose.
Channel/Port Timing
Channel/Port Timing are the various Timing reference signals that may selected on a particular interface module that resides in the Cell Exchange system. Normally that reference signal dictates how the timing on that particular channel/port will operate. The following timing options are available to various interface modules, although not all options are used on all modules:
•
Recovered Timing
•
On Board Timing
•
Reference Timing
•
Internal Timing
•
Dynamic Clock Tracking
Recovered Timing
In digital networks, the high-speed network interface circuit connected to the service provider’s network is normally used as the “master” timing reference. This digital interface is referenced in multiple geographic locations throughout the service provider’s network to a Stratum 1 reference source, which provides the network with a highly reliable and stable timing source. This timing source can be used as a timing source for the Cell Exchange system.
During initial configurations, the user can choose this timing source on most of the interface modules by selecting the interface circuit (A-B-C-D) connected to the service provider, and setting it as the reference timing source.
All designed modules have this capability to “recover” timing originating from the carrier circuit and phase-lock the 'reference clock' to it to produce various timing rates required by the Cell
Exchange system. If the circuit chosen to provide reference should fail, the Cell Exchange system will revert to the internal clock source as a secondary choice. All other modules may now use this timing as the timing reference.
On-Board Timing
On Board timing is the least stable of all timing sources and should only be used if no other timing source is available. On Board timing is provided as a source reference when testing the Cell
Exchange system in a 'back-to-back' mode. This timing source may be used by all the channel/ports on that particular module.
CXUG
7-31-98
1-9
This timing source may also be selected as of the 'reference' timing source. Selecting this timing source as the reference is accomplished in the same manner as for external timing, from the Timing
Configuration screen at the craft interface. Lower speed circuits may use this timing reference as a primary clocking source.
Reference Timing
Reference timing may be used on all modules select the 'reference' timing to be used to transfer data in and out of the selected interface on that module.
Internal Timing
Internal Timing is the clock that is resident on the CPU module and is presented to all the modules as an alternative timing selection. Internal Timing is also used for the 'fall-back' timing source in the case where the selected timing source failed in which case the 'fall-back' clock would then take its place until it is restored.
Dynamic Clock Timing
Dynamic Clock Timing is ONLY used on the DSL, QSL, and HSL Modules; no other modules have this feature. Dynamic Clock Timing derives timing from the clock that was inserted at the
'far-end' of the circuit. In Dynamic Clock timing the received cell data is buffered and continuously tracked. The tracking information is then processed by the on board CPU and used to control a
VCXO. The output of the VCXO is then used to shape the timing that is produced to clock the clear data out of the module to the terminal equipment.
NOTE:
When using any of the above clock sources as timing for a CBR-type emulation circuit, it is imperative that BOTH ends of the circuit are timed from the same source, and that they are synchronous with one another. If this is not done, transmit and receive timing will “slip” as the two clocks drift past one another.
External Timing
External Timing may be inserted into the Cell Exchange system by using the Station Clock Module
(SCM). External Timing is a source of timing derived from a customer who has a highly reliable and stable timing source apparatus, such as (LORAN or GPS) being used as a Master Station
Clock. The Master Station clock timing signal can then be injected into a Cell Exchange system and be used as the master timing source for all modules in either of these systems. From the craft interface, the user can select the SCM module as the source by entering the Timing Configuration screen and choosing the appropriate command. Lower speed circuits may use this timing reference for a primary clocking source.
1-10
CXUG
7-31-98
System Cooling
System cooling is accommodated through normal ventilation. No special cooling is required under most environmental conditions when the unit is lightly populated. Under severe operating conditions, such as extremely high ambient temperatures or high concentrations of dust, circulation aids, such as stacking fan units, may be required. A stacking fan arrangement is shown in Figure
1-6.
PRECAUTION: If more than half of the slots in the CX-1500 Cell
Exchange system are populated, overheating may occur if ventilation fans are not installed.
Figure 1-6. Cell Exchange with Stacking Fan Unit
Performance Characteristics
The physical, electrical, and environmental characteristics of the Cell Exchange system are shown in Table 1-2.
CXUG
7-31-98
1-11
Table 1-2. Physical, Electrical and Environmental Characteristics
Category
System Capacity (CX-1500)
System Capacity (CX-1540)
Enclosure Size (CX-1500)
Enclosure Size (CX-1540)
Chassis Weight (CX-1500)
Chassis Weight (CX-1540)
Clearance Requirements (Both)
Power Input (CX-1500)
Power Input (CX-1540)
Operating Environment (Both)
Standard Characteristics
Case with backplane
AC power supply
CPU card
14 empty slots
Case with backplane
AC power supply
CPU card
3 empty slots
5.25” high, 19” wide, and 13” deep
1.75” high, 19” wide, and 13” deep
22 - 32 pounds, depending upon configuration
8 - 11 pounds, depending upon configuration
1.75” above and below case recommended for ventilation
90 - 230 VAC, 47 - 63 Hz, 2.0 amps
90 - 230 VAC, 47 - 63 Hz, 0.8 amps
0
°
- 50
°
C
Up to 85% relative humidity; noncondensing at 50
°
C
Options
Up to 14 interface modules
DC power supply
Redundant power supply
Up to 3 interface modules
Same as standard
Same as standard
Same as standard
Same as standard
Same as standard
None
None
Same as standard
1-12
CXUG
7-31-98
Chapter
2
Installation
Site Preparation
Minimal site preparation is required for the Cell Exchange system. They are easily mounted into a standard 19-inch rack.
Equipment Installation
Unpacking
The Cell Exchange system is shipped in cartons with adequate packing material to protect them from damage due to shock and vibration. Upon receipt of either system, inspect the condition of the carton for obvious damage. After opening, inspect the equipment for signs of damage, and inventory the equipment against the enclosed packing list. Notify the carrier and TimePlex immediately if there is any damage or shortages.
Required Tools and Equipment
There are no special tools or equipment required for installation of the Cell Exchange system.
Chassis Installation Procedures
Installing a Cell Exchange system chassis into the rack is simply a matter of selecting a mounting position with adequate room and ventilation for the Cell Exchange. A Cell Exchange system should have at least the space of open one rack unit (1-3/4 inches) above and below to provide unrestricted airflow to the venting ports in the chassis.
Once the chassis is mounted on the tray (slides), push it back into the rack until the ears on each side of the front panel contact the rack. Secure the chassis to the rack with 4 screws.
CXUG
7-31-98
2-1
Grounding Requirements
Once the chassis is installed, ground the installation by attaching a grounding strap (not supplied) between the common equipment rack ground and the grounding lug located on the backplane.
WARNING: ALWAYS ENSURE THAT THE CELL EXCHANGE
SYSTEM IS PROPERLY GROUNDED BEFORE
COMMENCING OPERATIONS. INJURY TO PERSONNEL
AND DAMAGE TO THE EQUIPMENT COULD RESULT IF
THIS PRECAUTION IS NOT OBSERVED.
Power Connections
The Cell Exchange systems require AC input power in the range 90 - 230 VAC, 47 - 63 Hz.
Ensure that the available station power can meet this criteria. To make a power connection, plug one end of a power cord into the system receptacle on the backplane and the other end into the power source receptacle. Figure 2-1 shows the AC module (receptacle) mounted on the rear of the
CX-1500 chassis. Figure 2-2 shows the CX-1540.
WARNING: SECURE THE AC POWER CABLE TO THE AC
CONNECTOR ON THE REAR PANEL BEFORE
CONNECTING THE CABLE TO THE AC POWER
SOURCE. FAILURE TO COMPLY WITH THIS
PROCEDURE MAY RESULT IN ELECTRICAL SHOCK.
POWER SUPPLY A
!
CAUTION: For continued protection from risk of fire, replace with only same type and rating of fuse.
O
I
115 VAC 60 Hz Use 3.0 Amp 250 V Fuse
POWER SUPPLY B
O
I
Figure 2-1. CX-1500 AC Power Connector Module (Rear Chassis)
2-2
CXUG
7-31-98
I
O
100 - 230 VAC
Use 3.0 Amp 250 V Fuse
!
CAUTION: For continued protection from risk of fire, replace with only same type and rating of fuse.
Figure 2-2. CX-1540 AC Power Connector Module (Rear Chassis)
Module Installation Procedures
The CX-1500 system is delivered with all user-specified modules installed. If additional modules are need to be subsequently installed, follow these basic procedures:
1.
Select an available open slot to install the new module.
PRECAUTION: The CPU Module must be installed in slot 8 of Model CX-
1500 and in any slot except slot 1 of Model CX-1540.
2.
Loosen the two captive screws holding the blank front panel to the chassis.
3.
Insert the module into the chassis. Use care to ensure that the DIN connector is correctly lined up and fully seated into the backplane.
4.
Tighten the two screws that attach the module front panel to the chassis.
NOTE:
Never force the screws when starting them. If they become difficult to turn, back them off and start over.
5.
Attach required cable(s) to module connector(s)
6.
Since certain modules may have fiber optic components, the two following notes should be carefully observed.
PRECAUTION: Working with fiber optic cables can be hazardous to personnel and, if mishandled, can cause permanent damage to the cables.
WARNING: THE FIBER-OPTIC CONNECTORS MAY EMIT LASER
LIGHT THAT CAN INJURE YOUR EYES. NEVER LOOK
INTO AN OPTICAL FIBER CONNECTOR OR CABLE.
CXUG
7-31-98
2-3
Chapter
3
Modules
This section provides a functional overview of installable Cell Exchange system modules. The Cell
Exchange system is a modular and scalable cell multiplexer, which operates using ATM Cell Bus architecture. An ATM Cell platform is provided that serves on the “net edge” to concentrate both
Cell (ATM and frame relay) and Legacy (non-ATM) serial traffic.
Summary of Modules
The tables below summarize the functions performed by the various modules available for the Cell
Exchange systems.
Table 3-1. Module Summary
Common Modules and Station Clock Module
CPU Module
Component
Power Supply Module
Station Clock Module (SCM)
Function
•
Configuration, control and management functions
•
Controls processors on other modules
•
Converts AC input voltage to +5 VDC output
•
Converts +5 VDC to +1.2 VDC
•
Monitors the attached clock signal for activity
T1 Interface Module (T1C)
OC-3 Interface Module (OC3)
Cell Bearing Interface Modules
•
Accepts T-1 cell data
•
Places the cells on the ATM cell bus
•
Monitors physical interface
•
Collects module performance statistics
•
Accepts OC-3 ATM cell data
•
Places the cells on the ATM cell bus
•
Monitors physical interface
•
Collects module performance statistics
CXUG
7-31-98
3-1
3-2
Table 3-1. Module Summary (Cont’d)
Cell Bearing Interface Modules (Cont’d)
Component
Dual Synchronous Cell Interface
Module (DSC)
DS-3 Cell Interface Module (DS3)
Function
•
Accepts synchronous cell traffic and monitors for corrupted traffic
•
Sends resynchronization signal if corrupted traffic discovered
•
Places the cells on the ATM cell bus
•
Monitors physical interface
•
Collects module performance statistics
•
Accepts cell traffic and converts the data to ATM
CBR cells
•
Places the cells on the ATM cell bus
•
Monitors the physical interface
•
Collects module performance statistics
Structured T1 Legacy Interface
Module (STL)
Non-Cell Bearing Interface Modules
•
Accepts voice or data from T-1 channel groups and passes it to/from ATM cell bearing equipment
•
Monitors the physical interface
•
Collects module performance statistics
Synchronous Legacy Interface
Module—Dual Channel (DSL)
High Speed Synchronous Legacy
Interface Module (HSL)
•
Accepts synchronous non-cell (legacy) traffic and converts the data to ATM CBR cells
•
Places the cells on the ATM cell bus
•
Monitors the physical interface
•
Collects module performance statistics
•
Accepts synchronous non-cell (legacy) traffic and converts the data to ATM CBR cells
•
Places the cells on the ATM cell bus
•
Monitors the physical interface
•
Collects module performance statistics
CXUG
7-31-98
CPU Module
Overview
The CPU Module is designed around a Motorola 68340 microprocessor, and is used to control, configure, collect statistics, and provide all general management functionality within the unit. The
CPU module also provides master timing for the cell bus. A view of the front panel of the CPU
Module is shown in Figure 3-1.
CPU
OPNL
FAIL
ACTV
ACCS
CXUG
7-31-98
CPU
Figure 3-1. Front Panel of CPU Module (CPU)
The CPU Module provides all configuration, control, and management functions for the Cell
Exchange system, either from a local craft interface, or remote SNMP management feature. The
CPU module controls all microprocessors/controllers on other modules located in the same chassis, using the ATM bus message format structure. The CPU module (ATM bus) is also responsible for
ATM Q.2931 signaling between the Cell Exchange system and local/remote ATM switches. A functional block diagram of the CPU Module is shown in Figure 3-2.
3-3
LEDs
DB9
DRIVERS
&
RECEIVERS
CPU 68340
ATM CELL
BUSS
SWITCH
Figure 3-2. CPU Module Functional Diagram
Cell Bus-Microprocessor-Power Section
The Cell Bus-Microprocessor-Power section of the CPU module consists of the following:
•
ATM Cell Bus Switching Logic IC (ATM Cell Bus Switch), along with a RAM IC, provides connectivity to the backplane board
•
96-Pin DIN connector, used to connect onto the ATM Cell Bus
•
Motorola 68340 microprocessor
•
Battery-backed RAM
•
Capacitor filtering, provided for control and noise suppression
•
DB-9F connector to interface with an external VT100 type device for the craft interface
Unique Module Functionality Section
A DB-9 female connector installed on the front of the module is used for configuration and diagnostics on the Cell Exchange system. The drivers and receivers used for this interface are asynchronous and meet RS-232C interface standards. Four LEDs are mounted on the front panel of the interface module. These LEDs provide indications of the functioning of the module.
3-4
CXUG
7-31-98
Indicators
Type
LED
LED
LED
Label
OPNL
FAIL
ACTV
LED ACCS
Color
Green Module is operational
Meaning
Red CPU module has failed
Green On - Module is active
Off - Module is standby
Yellow Indicates that CPU module is being accessed from craft interface
Pinouts
Pinouts for the DB-9M (DTE) connector on the CPU module are as shown in Figure 3-3 and the accompanying table. The mating cable should use a Female DB-9 connector
Figure 3-3. DB-9M Connector
Pin
1
2
3
4
5
Direction Signal
N/C
RxD
TxD
N/C
Gnd
To CPU Module
Pin
6
7
8
9
Direction Signal
N/C
RTS
CTS
N/C
From CPU Module
CXUG
7-31-98
3-5
AC Power Supply Module
In the CX-1500 chassis, the power supply slots are located in the left-most part of either chassis. A single power supply module may be installed in either slot. The remaining slots may be populated with any type module. In the Model 1540 chassis, the single power supply module is installed internally.
Depending on the type of chassis, one or two power supply modules may be installed. One Power
Supply Module will handle the full power load required for the number of interface modules placed in the chassis, with a reserve capacity of 40% above the maximum load capability, although a second module may be installed (Model 1500 only) for enhanced reliability. The Power Supply
Modules feature a “solid state” switcher design. If two modules are installed, the modules are coupled to supply redundant power to the bus. The Power Supply Modules are designed to allow removal and replacement into a working unit without affecting active operational traffic (hot swap). Each Power Supply Module has its own AC power connector and cord.
AC power distribution within the CX-1500 CMC is relatively simple. Standard AC power is received at the backplane of the chassis and transferred via the power connector interface to the
Power Supply Module. The Power Supply Module converts the AC input to +5 VDC for transistor-transistor logic (TTL) use, then sends it to a voltage regulator and the backplane bus.
The voltage regulator reduces the +5 VDC input to a +1.3 VDC output for Gunning Transistor
Logic (GTL) use. There are three signal components to the DC power output: +5 VDC (TTL),
+1.3 VDC (GTL), and ground. A functional block diagram of the AC power supply module is shown in Figure 3-4.
LEDs
POWER
SUPPLY
GTL
VR
AC
INPUT
Figure 3-4. AC Power Supply Module Functional Diagram
3-6
CXUG
7-31-98
Specifications
Input Voltage:
Input Frequency:
Input Current
Output Voltage:
Indicators
90 to 230 VAC
47 to 63 Hz
2.0 amps (CX-1500) or
0.8 amps (CX-1540)
+5 VDC
Type
LED
LED
Label
POWER
FAIL
Color
Green
Red
Meaning
Indicates that +5V is being read at the bus
Power supply module has failed or no AC is present
CXUG
7-31-98
3-7
Station Clock Module (SCM)
Overview
The Station Clock (SCM) Interface Module allows the user to input and propagate an external clock source into the Cell Exchange to be used as the internal reference clock for the unit. The
SCM requires a balanced electrical input signal. The clock rate may be selected at a rate from
1 MHz to 50 MHz in 8 KHz steps. The front panel of the SCM is shown in Figure 3-5.
SCM
OPNL
CLCK
ACTV
3-8
SCM
Figure 3-5. Station Clock Module (SCM)
The Station Clock Module performs the following primary functions:
•
Accepts an external timing signal from a Maser Station Clock
•
Monitors the attached clock signal for activity
CXUG
7-31-98
Specifica
t
ions
Port Capacity:
Media:
Electrical:
Connector:
Line Format:
Clock Rates:
Power:
Indicators
Type
LED
LED
LED
Label
OPNL
CLCK
ACTV
One
Shielded Multi-twisted pair cable, low capacitance
EIA-530, DCE
HDB-26, Female
Balanced
8 KHz - 50 MHz (in 8 KHz increments)
≤
7 Watts
Color
Green
Green
Green
Meaning
Module is operational
External clock source is present at the interface connector
SCM is selected as timing reference on timing screen
Pinouts
The high-speed DB-26 connector pinouts are shown in Figure 3-6 and the accompanying table.
Figure 3-6. HDB-26F (DCE) Pin Location
Direction Pin
1
7
13
21
Signal
FG
SG
TTA
TTB
From Master Clock Source
All other pins are N/C (No Connection)
CXUG
7-31-98
3-9
Dual T-1 Cell Interface Module (T1C)
Overview
The Dual T-1 Cell Bearing Module is part of a broad group of standard interface modules designed for use in the ATM Cell Exchange systems. The Dual T-1 Cell Bearing Module is a compact subassembly that occupies one of the slots available in the Cell Exchange system. It can connect to other equipment as a DSX-1 interface or terminate a public T-1 on its built-in T-1 CSU. A front panel view of the Dual T1 Cell Interface Module is shown in Figure 3-7.
OPNL
Rx Syn
Ce Syn
Rx Syn
Ce Syn
T1C
Figure 3-7. Dual T1 Cell Interface Module (T1C)
Cell Bus-Microprocessor-Power Section
The Cell Bus-Microprocessor-Power section of the T1C module consists of the following:
•
ATM Cell Bus Switching Logic IC (ATM Cell Bus Switch), along with a RAM IC, provides connectivity to the backplane board
•
96-Pin DIN connector, used to connect onto the ATM Cell Bus
•
Intel 80C31 microprocessor
•
Battery-backed RAM
•
Capacitor filtering, provided for control and noise suppression
3-10
CXUG
7-31-98
•
RJ-45 connector to interface with external devices
Unique Module Functionality Section
The Dual Cell Bearing T-1 Module terminates two independent T-1 facility interfaces, recovers clock, accesses the ATM cells within the T-1 payload, and sends these cells to the switching fabric.
In the transmit direction the process is reversed. ATM cells are taken off the switching fabric and mapped into the T-1 framed payload, which is then formatted per ATM Forum specifications and clocked out on the T-1 facility. A functional diagram is shown in Figure 3-8.
INTERFACE
DRIVERS & RECEIVERS
INTERFACE
DRIVERS & RECEIVERS
TYPE
FUNCTIONS
(AAL1)
MEMORY
ATM CELL
BUSS
SWITCH
SRAM
CPU 80C31
Figure 3-8. Dual T1 Cell Interface Module Functional Diagram
Specifications
Port Capacity:
Interface:
Media:
Connector:
Line Encoding:
Data Format:
Timing:
Diagnostics:
Alarm:
Alarm/Statistics:
Two (2)
DSX-1 or CSU (Software configurable)
Shielded, Twisted pair
RJ-45, Female (DCE)
AMI, B8ZS
ATM Cells
Recovered Receive T-1 rate, External Timing Reference, Internal 1.544
MHz (+/- 100 ppm)
Facility and Terminal Loopback
LOF, LOC, BPV, AIS, Red and Yellow Alarms
LCV, FER, CRC-6, OOF, HCS, Rx CELLS, Tx CELLS
CXUG
7-31-98
3-11
Compliance: ATM Forum DS1 UNI v3.1, af-phy-0016.0000, ANSI/Bellcore DSX-1,
T1.102, T1.107, T1.408, TR-TSY-000009, ITU-T G.703, G.804, AT&T
62411
Indicators
Type
LED
LED
LED
Label
OPNL
Rx Syn
Ce Syn
Color
Green
Green
Green
Meaning
Indicates that module has successfully received configuration from
CPU and is operational
Receive Synchronization
Cell Synchronization
Pinouts
Pinouts for the RJ-45 connectors are as shown in Figure 3-9 and the accompanying table.
Pin
1
2
1
2
4
5
Rx (to T1C)
Tx (to Network)
Figure 3-9. Pin Location
Direction
To T1C
To T1C
Signal
Rx-R
Rx-T
Pin
4
5
Direction
To Network
To Network
Signal
Tx-R
Tx-T
3-12
CXUG
7-31-98
OC-3 Cell Interface Module (OC3)
Overview
The OC-3 Cell Interface Module terminates an OC-3 facility interface, recovers clock, accesses the
ATM cells within the SONET payload, and provides these cells to the Cell Exchange system switching fabric. The OC-3 module comes in the following four configurations:
•
Multimode (MM)
•
Single Mode (SM)
•
Multimode (MM)
•
Single Mode (SM)
STS-3c format
STS-3c format
SDH STM-1 format
SDH STM-1 format
The OC-3 Cell Interface Module is part of a broad group of standard Interface Modules that have been developed for the Cell Exchange system. The OC-3 Cell Module allows the Cell Exchange system to interface with ATM switches, Engineering Workstations and ATM cell bearing transmission systems. The data rate is 155 Mbps. The module performs the following primary functions:
•
Take OC-3 ATM cell data and uncouple the cells from the physical OC-3 interface
•
Take the cells and place them onto the ATM Cell bus
•
Monitor the physical interface for alarms
•
Collect statistics on module performance.
A front panel view of the OC-3 Cell Interface Module is shown in Figure 3-10.
Laser Radiation Hazards
The OC-3 interface module, if installed, emits a laser beam onto a fiber optic connection. Observe the precaution and warning listed below.
PRECAUTION: Working with fiber optic cables can be hazardous to personnel and, if mishandled, can cause permanent damage to the cables.
WARNING: THE FIBER-OPTIC CONNECTORS MAY EMIT LASER
LIGHT THAT CAN INJURE YOUR EYES. NEVER LOOK
INTO AN OPTICAL FIBER CONNECTOR OR CABLE.
CXUG
7-31-98
3-13
OC3
OPNL
Rx Syn
Ce Syn
OC3
Figure 3-10. OC-3 Cell Interface Module (OC3)
Cell Bus-Microprocessor-Power Section
The Cell Bus-Microprocessor-Power section of the OC-3 module consists of the following:
•
ATM Cell Bus Switching Logic IC (ATM Cell Bus Switch), along with a RAM IC, provides connectivity to the backplane board
•
96-Pin DIN connector, used to connect onto the ATM Cell Bus
•
Motorola 68340 microprocessor
•
Capacitor filtering, provided for control and noise suppression
•
Optical connector to interface with external devices
Unique Module Functionality Section
The OC-3 Cell Module is a compact subassembly which provides the hardware necessary to terminate a OC-3 facility interface, recover clock, access the ATM cells within the SONET payload, and provide these cells to the Model 1500 switching fabric. In the transmit direction the process is reversed. ATM cells are taken off the switching fabric and mapped into the SONET payload, which is then properly formatted and clocked out on the OC-3 facility. A functional diagram of the OC-3 Cell Interface Module is shown in Figure 3-11.
3-14
CXUG
7-31-98
LED
OC-3
SUBMODULE
ATM CELL
BUSS
SWITCH
MEMORY
CPU 68340
LED
Figure 3-11. OC-3 Cell Interface Module Functional Diagram
Two types of OC-3 submodules are available to allow the user to select various drive distances.
The only differences are the fiber optic components, one being LED and the other MLM Laser.
These submodules are interchangeable on the Cell Exchange OC-3 interface module.
Reach
Short (0-2 km)
Short/Intermediate (0-15 km)
Source
LED
MLM Laser
Fiber Type
Multi-mode
Single Mode
Connector
SC-Duplex
SC-Duplex
There are 2 interfaces offered as part of the OC-3 Cell Module Interface section. The OC-3 interface is summarized in the following table:
Interface
RCV_OC3 Interface
XMT_OC3 Interface
Function
Provides the physical interface for the OC-3 Receive SONET interface.
Provides the physical interface for the OC-3 Transmit SONET interface.
Optical Transceiver Options
The following optical transceiver options are available:
•
Multimode Fiber - SC-Duplex Connector, source LED
•
Single Mode Fiber - SC-Duplex Connector, source MLM Laser
CXUG
7-31-98
3-15
Specifications
Port Capacity:
Media:
One
Short Haul (Multimode) Fiber
Long Haul (Single mode) Fiber
SC Duplex Connector Connector:
Line Encoding:
Framing:
Transmit Clock:
Non-Return to Zero (NRZ)
STS-3c/STM-1
Recovered Receive OC-3 rate
On Board 155.52 MHz (+/- 20 ppm)
Translation Capacity: 256 VPIs, 10,240 VCIs
Diagnostics: Facility Loopback
Terminal Loopback
Alarm Surveillance: Section, Line, and Path
Alarms/Statistics: LOS, LOF, LOP, FEBE, AIS, FERF, Yellow alarm, BIP, HCS
Maintenance Actions: SONET maintenance signaling generation RDI and AIS.
Compliance:
Power:
ATM Forum STS-3c UNI v3.1, ITU-T I.432, ANSI T1E1.2/93-020,
T1S1/92-158, ITU-T G.957, Bellcore TR-NWT-000253
≤
7 Watts
Optical Transmitter Specifications
:
Min.
1260
Type
1310
Description
Wavelength
RMS Special Bandwidth
∆λ rms
Average Transmitted Power
Pt
Extinction Ratio remin
Module
both
MM
SM
MM
SM
MM
SM
-20
-15
10
8.2
-17
-11.5
Max.
1360
75
7.7
-14
-8
Units
nm nm nm dBm dBm dB dB
Optical Receiver Specifications:
Description
Average Received Power Pr
Optical Path Power Penalty Po
Module
MM
SM
Both
Min.
-30
-28
Type Max.
-14
-8
1
Units
dBm dBm dB
3-16
CXUG
7-31-98
Jitter Characteristics:
Jitter Frequency
500 Hz - 1.3 MHz
65 kHz - 1.3 MHz
Meets Bellcore’s requirement from TR-NWT-000253.
Maximum Jitter Amplitude (UI p-p)
1.5
0.15
ATM Physical Layer Processing: per ATM Forum's User-Network Interface (UNI) Specification
3.0
Compliance: ATM Forum STS-3c UNI v3.1, ITU-T I.432, ANSI T1E1.2/93-020,
T1S1/92-185, ITU-T G.957, Bellcore TR-NWT-000253
Indicators
Type
LED
LED
LED
Label
OPNL
Rx Sync
Ce Sync
Color
Green
Green
Green
Meaning
Indicates that module has successfully received configuration from CPU and is operational
Receive Synchronization
Cell Synchronization
Pinouts
Pinouts for the SC connector are as shown in Figure 3-12.
R x
Tx
Figure 3-12. SC Connector
CXUG
7-31-98
3-17
Dual Synchronous Cell Interface Module(DSC)
Overview
The Dual Synchronous Cell Module is part of a broad group of standard Interface Modules that have been developed to be used with the ATM Cell Exchange systems. A front panel view of the
Synchronous Cell Interface Module is shown in Figure 3-13.
DSC
OPNL
DSC
3-18
Figure 3-13. Dual Synchronous Cell Interface Module (DSC)
The Dual Synchronous Cell Module is a compact subassembly designed to be used as a major system building block component in the Cell Exchange system. The Dual Synchronous Cell
Module provides the necessary hardware required to terminate two Synchronous interfaces, recover clock, access the ATM cells within the payload data stream, and provide these cells to the Cell
Exchange switching fabric. In the transmit direction the process is reversed. ATM cells are taken off the switching fabric and mapped into the payload data stream, which is then properly formatted and clocked out on the synchronous facility. Figure 3-14 shows a functional diagram of the Dual
Synchronous Cell Interface Module.
CXUG
7-31-98
INTERFACE
DRIVERS & RECEIVERS
INTERFACE
DRIVERS & RECEIVERS
CELL
DELINEATION
BLOCK
DEVICE
CELL
DELINEATION
BLOCK
DEVICE
MEMORY
CPU 80C31
ATM CELL
BUSS
SWITCH
ATM CELL
BUSS
SWITCH
Figure 3-14. Dual Channel Synchronous Cell Interface Module Functional Diagram
Cell Bus-Microprocessor-Power Section
The Cell Bus-Microprocessor-Power Section of the Synchronous Cell Module is similar to that of the OC-3 Cell Module, except that it contains additional components to accommodate dual channels.
Unique Functionality Section
The Unique Functionality Section of the Synchronous Cell Module features the following:
•
Module is equipped with two independent channels
•
Connectors are High-Density DB-26 female type (DTE)
•
Drivers and receivers conform to EIA - 530
•
A Cell Delineation Block Device circuit provides Header Error Control (HEC) checks on the incoming cell synchronous data stream to provide a reset signal to the encryption device
Specifications
Port Capacity:
Media:
Electrical:
Connector:
Line Format:
Two (2)
Shielded Multi-twisted pair cable, low capacitance
EIA - 530, DTE
HDB-26, Female
Balanced
Data Rates: 16 Kbps-20 Mbps (in 8 Kbps increments)
Translation Capacity: 256 VPIs, 10,240 VCIs (per port)
CXUG
7-31-98
3-19
Diagnostics:
External Timing Reference
Internal
Facility Loopback
Terminal Loopback
Alarm – Surveillance: HEC
Crypto-Reset Signal: Single-ended, EIA - 530 (activated on corrupted HEC)
ATM Layer:
Compliance:
AAL 1, CBR
ITU-T I.432, af-phy.0043.000
Indicators
Type
LED
Label
OPNL
Color
Green
Meaning
Indicates that module has successfully received configuration from CPU and is operational
Pinouts
Pinouts for the high-speed DB-26F connectors are as shown in Figure 3-15 and the accompanying table.
Figure 3-15. HDB-26F (DTE) Pin Location
3-20
CXUG
7-31-98
CXUG
7-31-98
Pin
1
4
5
6
2
3
11
12
13
9
10
7
8
Direction Signal
FG
SDA
RDA
RSA
CSA
DMA
SG
RRA
LL
TM
SDB
RDB
TTA
To DSC Module
Pin
14
15
16
17
18
19
24
25
26
20
21
22
23
Direction Signal
CSB
STA
DMB
RTA
RRB
TRB
TRA
TTB
RSB
STB
RL
RTB
KGRST
To Network
3-21
DS-3 Cell Interface Module (DS3)
Overview
The DS-3 Cell Interface Module allows the Cell Exchange system to interface with ATM cell bearing communications equipment. A front panel view of the DS-3 Cell Interface Module is shown in Figure 3-16.
DS3
OPNL
Rx Syn
Ce Syn
DS3
Figure 3-16. DS-3 Cell Interface Module (DS3)
The DS-3 Cell Interface Module performs the following primary functions:
•
Takes the cells and places them onto the ATM cell bus
•
Monitors the physical synchronous interface for alarms
•
Collects statistics on module performance
Cell Bus-Microprocessor-Power Section
The Cell Bus-Microprocessor-Power section of the DS-3 module consists of the following:
3-22
CXUG
7-31-98
•
ATM Cell Bus Switching Logic IC (ATM Cell Bus Switch), along with a RAM IC, provides connectivity to the backplane board
•
96-Pin DIN connector, used to connect onto the ATM Cell Bus
•
Motorola 68340 microprocessor
•
Capacitor filtering, provided for control and noise suppression
Unique Functionality Section
The DS-3 Cell Interface Module indicates the following unique functions:
•
Module equipped with one complete DS-3 channel
•
Connectors are BNC type
•
DS-3 Interface electrical specifications on the drivers and receivers conform to NSA NO. 87-
20A Specification
A functional diagram of the DS-3 Cell Interface Module is shown in Figure 3-17.
INTERFACE
DRIVERS & RECEIVERS
TYPE
FUNCTIONS
(AAL1)
MEMORY
CPU 68340
ATM CELL
BUSS
SWITCH
SRAM
Figure 3-17. DS-3 Cell Interface Module Functional Diagram
Specifications
Port Capacity:
Media:
Connector:
CXUG
7-31-98
One (1)
Coaxial Cable
BNC Female
3-23
Line Rate:
Signal Format:
44.736 Mbps
C-Bit Parity per ANSI T1.107a
M23 per ANSI T1.107
Recovered Receive DS-3 rate Transmit Clock:
On-Board 44.736 MHz (+/- 20 ppm)
Translation Capacity: 256s, 10,240 VCIs
Diagnostics: Signal Loopbacks, Self-Test
Alarm – Surveillance: LOS, LOF, LOC, AIS, Sync Fail, Hardware Fail, FERM, PLCP Path
RAI, DS3 Path RFI
Alarm/Statistics:
Compliance:
Power:
Compliance:
Physical Layer, Line Layer, DS3 Path Layer, PLCP Path Layer, and
ATM Layer
ATM UNI v3.1, ANSI T1.107-1988, ANSI T1.107a-1990, ANSI
T1.231-1993, ITU-TS Docs. I.432, I.610, G.703, G.804
≤
7 Watts
ATM Forum STS-3c UNI v3.1, ITU-T I.432, ANSI T1E1.2/93-020,
T1S1/92-185, ITU-T G.957, Bellcore TR-NWT-000253
Indicators
Type
LED
LED
LED
Label Color Meaning
OPNL Green Indicates that module has successfully received configuration from CPU and is operational
Rx Syn Green Receive Synchronization
Ce Syn Green Cell Synchronization
Pinouts
Pinouts for the BNC connectors are as shown in Figure 3-18.
R x
Tx
Figure 3-18. BNC Pin Location
3-24
CXUG
7-31-98
Structured T-1 Legacy Module (STL)
Overview
The Structured T1 Legacy (STL) module allows voice and data contained in T1 channel groups
(one or more 64KHz ds0 channels) to be passed to and from ATM cell bearing equipment. The
STL card supports either 4 or 8 T1 interfaces. Both ESF and SF framing formats are supported
(T1 interface configuration is discussed in the following section). A front panel view of the
Structured T1 Legacy Interface Modules is shown in Figure 3-19.
STL
OPNL
A
B
C
D
STL
OPNL
A C
B D
E
F
G
H
CXUG
7-31-98
STL
STL
4-Port 8-Port
Figure 3-19. Structured T1 Legacy Interface Module (STL)
Channel groups are configured as either voice or data. For channels configured as data, the STL sets up “clear channel” (64KHz) connections. For voice connections, the STL enables in-band
(“robbed bit”) signaling to pass through the network (Figure 3-20).
The user defines the various voice and data channel groupings via the STL interface configuration menu described in the configuration chapter. Each channel group consists of one or more channels.
The channels can be either contiguous or non-contiguous.
3-25
3-26
4 or 8 T1
Interfaces
T1
.
.
24
.
.
1
.
.
STL
24 ds0 x 1 channel
groups
SAR
.
.
.
.
24
1
2
3
.
VPI/VCI
VPI/VCI
ATM
Network
Each T1 channel mapped to different VPI/VCI pairs
Figure 3-20. T1 Mapping
STL connections are established via the connection management menu—configuring STL connections” follows. The Cell Exchange system allows any channel group to be connected to:
•
Any VPI/VCI of any configured cell bearing interface
•
Any “compatible” STL channel group, that is, any channel group that carries the same type of traffic (voice or data) and contains the same number of channels (Figure 3-21)
STL
T1
4 or 8 T1
Interfaces
T1
STL
.
.
.
.
1
.
.
24
ds0 channel
groups
2
5
7
1
3
8
SAR
VPI/VCI
VPI/VCI
ATM
Network
STL
T1
Two STL-to-VPI/VCI connections
Figure 3-21. STL to VPI/VCI Connections
The STL utilizes an AAL1 Segmentation And Reassembly (SAR) processor to pass data to and from the ATM network. In Figure 3-22 below, two connections that have been established between a T1 interface and the ATM network. In this example, T1 channels 1, 3, and 8 are mapped to one
VPI/VCI pair, and channels 2, 5, 7 are mapped to another VPI/VCI pair.
CXUG
7-31-98
4 or 8 T1
Interfaces
T1
STL
SAR
1
.
.
.
.
.
.
24
one ds0 x 24 channel
group
1
2
.
.
.
.
24
VPI/VCI
ATM
Network
All 24 T1 channels mapped to one VPI/VCI pair
Figure 3-22. Channel Mapping
For STL-to-STL connections, the actual channel numbers of each group may differ at each end as long as each group contains the same number of channels. The ordering of channels passed from the source channel group to the destination channel group is always preserved. In other words, the first channel of the destination receives the data from the first channel of the source; the second channel of the destination receives the data from the second channel of the source, and so on.
STL Operation
Interface Loopback
Any STL interface can be looped back via the loopback option of the diagnostics menu. When loopback is enabled, the STL configures the interface for remote loopback (to connected equipment) as well as framer loopback (all T1 transmit data is looped back to the receiver).
STL to T1 Cell Bearing Connections
[Note: For connections between STL channel groups and a T1 cell bearing interface, the total number of T1 channels must not exceed 20 channels. This is due to overhead required by ATM. If more than 20 channels are connected to T1 cell bearing interface, cells are discarded. The result of attempting to connect more than 20 channels is a significant loss of signal quality across all channels.]
Idle Channel Data Insertion
For channels configured as idle channels (not associated with any group), the STL inserts idle data according to the interface configuration settings.
When the idle channel conditioning is configured as “Data Idle,” the values inserted are:
•
0x7F (binary 01111111) if “Idle (UAC)” is selected as the trunk conditioning data code
CXUG
7-31-98
3-27
•
0x1A (binary 00011010) if “MUX-OOS” is selected as the trunk conditioning data code
When the idle channel conditioning is configured as “Voice Idle” the idle values inserted are:
•
0xFF (all ones) if “Idle(0)/Busy(1)” is selected for trunk conditioning signaling
•
0x00 (all zeroes) if “Busy(1)/Idle(0)” is selected for trunk conditioning signaling
Trunk Conditioning Logic
Trunk conditioning attempts to minimize the impact that link failures can have on connected equipment by inserting data and signaling into each of the affected channels according to the currently configured trunk conditioning parameters. Figure 3-23 shows a typical case of trunk conditioning.
4 or 8 T1
Interfaces
T1
1 link failure occurs here
STL
.
.
.
1
.
.
.
24
ds0 channel
groups
2
5
7
1
3
8
SAR
VPI/VCI
VPI/VCI
ATM
Network
STL
T1
1, 3, 8
2 cell loss detected, conditioning applied over affected channels toward connected equipment
STL
T1
2, 5, 7
Trunk Conditioning - example 1
Figure 3-23. Trunk Conditioning
The STL initiates trunk conditioning whenever 1) connections are disabled or 2) received cell loss occurs for 3 seconds. Trunk conditioning is applied in the outbound direction (toward the connected equipment). Trunk conditioning is applied only on the affected channels.
For data channels, trunk conditioning simply inserts the idle data into the affected channels.
For voice channels, idle data insertion is applied after trunk conditioning first toggles the signaling bits as follows:
•
All zeroes (2.5 sec) followed by all ones (2.5 sec) when “Idle (0)/Busy (1)” is selected for trunk conditioning signaling.
3-28
CXUG
7-31-98
•
All ones (2.5 sec) followed by all zeroes (2.5 sec) when “Busy (1)/Idle (0)” is selected for trunk conditioning signaling.
The STL removes trunk conditioning following 9 seconds of error-free cell reception. Figure 3-24 shows another typical example of trunk conditioning.
4 or 8 T1
Interfaces
T1
2 cell loss detected, conditioning applied over affected channels toward connected equipment
24
.
.
.
.
.
.
1
STL
1, 3, 8
1
3
8
SAR
ds0 channel
groups
2
5
7
VPI/VCI
VPI/VCI
ATM
Network
STL
1 link failure occurs here
T1
STL
T1
Trunk Conditioning - example 3
Figure 3-24. Another Example of Trunk Conditioning
T1 Signaling
As mentioned previously, the STL utilizes an AAL1 Segmentation And Reassembly (SAR) processor to pass the T1 data to and from the ATM network. For channel groups configured as voice, the STL directs the SAR to pass T1 signaling bits to and from the ATM network as well.
In the inbound direction (from a T1 interface into the ATM network), the SAR extracts signaling bits for each T1 channel and combines them into a single cell (separate from the actual data) for transmission through the ATM network. In the outbound direction (from the ATM network to a
T1 interface), the SAR extracts the signaling bits from these “signaling only” cells and inserts them into the correct T1 channels. This scheme allows signaling to be passed even if the T1 framing formats of the source and destination T1 interfaces differ.
ESF provides four signaling bits (the A, B, C, and D bits) while SF provides only two (the A and B bits). If a voice connection is configured between a channel group of a T1 ESF interface and a channel group of a T1 SF interface, signaling is affected as follows:
•
ESF inbound signaling bits A and B are mapped to SF outbound bits A and B, respectively
•
ESF inbound signaling bits C and D are lost since SF defines only two signaling bits
•
SF inbound signaling bit A values are mapped to two outbound ESF signaling bits A and C
•
SF inbound signaling bit B values are mapped to two outbound ESF signaling bits B and D
CXUG
7-31-98
3-29
T1 Alarms
The STL sends a yellow alarm toward the connected equipment whenever a red alarm (loss of signal) is present for a period of 3 seconds. The STL removes the yellow alarm when a signal is present for at least 9 seconds.
Specifications
Port Capacity:
Electrical:
Media:
Connector:
Line Encoding:
Framing:
Timing:
Four (4) or Eight (8)
DSX-1 or CSU
T-1, Twisted Pair Cable
RJ-45, Female (DCE)
AMI, B8ZS
SF (D4), ESF
Recovered, Internal, and External
Diagnostics: Facility and Terminal Loopback
Alarm - Surveillance: LOF, LOS, BPV, AIS, Red and Yellow Alarms
Alarm/Statistics:
Compliance:
Physical Layer, Line Layer, T-1 Path Layer, ATM Layer
ATM Forum DS1 UNI v3.1, af-vtoa0078.000 Channel Emulation
Service (CES) v2.0, 1/97, ANSI/Bellcore DSX-1, T1.102, T1.107,
T1.408, T1.403-1989, TR-TSY-000009, ITU-T G.703, G.804, AT&T
62411
Translation Capacity: 256 VPIs, 10,240 VCIs
Power:
≤
7 Watts
Indicators
Type
LED
Label
OPNL
Color
Green
LED (One per I/F)
A-D (4 port)
A-H (8 port)
Green
Meaning
Illuminated whenever the STL card is working properly and at least one T1 interface has been configured
STL has detected T1 frame synchronization on a configured interface. Extinguishes if channel dead or LOF
3-30
CXUG
7-31-98
Pinouts
All of the RJ 45 connectors on the STL 4 and 8 have the following pin-outs. Pins 1 and 2 are
Transmit out to the terminal equipment (PBX in most cases.) Pins 4 and 5 are Receive in from the terminal equipment (PBX in most cases.) Pinouts for the RJ 45 connector are shown in Figure
3-25.
4
5
1
2
Tx (to terminal equipment)
Rx (from terminal equipment)
Pin
1
2
Direction
To TE
To TE
Signal
Tx-R
Tx-T
Figure 3-25. Pinouts
Pin
4
5
Direction
To STL
To STL
Signal
Rx-R
Rx-T
CXUG
7-31-98
3-31
Synchronous Legacy Interface Modules (DSL)
Overview
The Synchronous Legacy Interface Module (DSL) allow the Cell Exchange to interface with non-
ATM cell bearing Military/Government encryption equipment on the Black or Network side at speeds up to and including 50 Mbps. The synchronous channels operate in steps of 8 Kbps. A front panel view of the Dual-channel Synchronous Legacy Interface Module is shown in Figure 3-26.
DSL
OPNL
DSL
3-32
Figure 3-26. Synchronous Legacy Interface Modules (DSL)
The Synchronous Legacy Interface Module performs the following primary functions:
•
Takes synchronous non-cell bearing traffic (Legacy traffic) and converts the data stream to
ATM CBR cells, adding the appropriate cell overhead
•
Takes the cells and places them onto the ATM cell bus
•
Monitors the physical synchronous interface for alarms
CXUG
7-31-98
•
Collects statistics on module performance
Cell Bus-Microprocessor-Power Section
The Cell Bus-Microprocessor-Power section of the Synchronous Legacy Interface Module consists of the following:
•
ATM Cell Bus Switching Logic IC (ATM Cell Bus Switch), along with a RAM IC, provides connectivity to the backplane board
•
96-Pin DIN connector, used to connect onto the ATM Cell Bus
•
Intel 80C31 microprocessor
•
Capacitor filtering, provided for control and noise suppression
Unique Functionality Section
The Synchronous Legacy Interface Module includes the following unique functions:
•
Module equipped with one complete independent synchronous channel
•
Connector is a High Density DB-26 female type
•
Synchronous Channel Interface electrical specifications on the drivers and receivers conform to
NSA NO. 87-20A Specification
•
Configured as a DCE device using a DB-26F high density connector
•
High-speed AAL1 segmentation and reassembly function process data speeds up to and including 50 Mbps at the user interface (CBR type)
A functional diagram of the Synchronous Legacy Interface Module is shown in Figure 3-27.
INTERFACE
DRIVERS & RECEIVERS
INTERFACE
DRIVERS & RECEIVERS
TYPE
FUNCTIONS
(AAL1)
MEMORY
ATM CELL
BUSS
SWITCH
SRAM
CPU 80C31
CXUG
7-31-98
Figure 3-27. Synchronous Legacy Interface Module (DSL) Functional Diagram
3-33
Specifications
Port Capacity:
Media:
Electrical:
Connector:
Line Format:
Data Format:
Data Rates:
Timing:
Two
Shielded Multi-twisted pair cable, low capacitance
EIA RS-530, DCE
HDB-26, Female
Balanced
ATM Cells
128 Kbps-50 Mbps (in 8 Kpbs increments)
Recovered Receive Timing
External Timing Reference
Diagnostics:
Internal
Facility Loopback
Terminal Loopback
Alarm – Surveillance: HEC
Compliance : ITU-T I.432, af-phy.0043.000
3-34
CXUG
7-31-98
Indicators
Type
LED
Label
OPNL
Color
Green
Meaning
Indicates that module has successfully received configuration from
CPU and is operational
Pinouts
Pinouts for the high-speed DB-26 connectors are as shown in Figure 3-28 and the accompanying table.
CXUG
7-31-98
5
6
7
3
4
Pin
1
2
10
11
8
9
12
13
Direction Signal
FG
SDA
RDA
RSA
CSA
DMA
SG
RRA
LL
TM
SDB
RDB
TTA
To DSL Module
Figure 3-28. HDB-26F (DCE) Pin Location
16
17
18
19
20
Pin
14
15
21
22
23
24
25
26
Direction Signal
CSB
STA
DMB
RTA
RRB
TRB
TRA
TTB
RSB
STB
RL
RTB
KGRST
To Terminal
3-35
High-Speed Synchronous Legacy Interface
Module (HSL)
Overview
The High Speed Synchronous Legacy Interface Module (HSL) allows the Cell Exchange to interface with non-ATM cell bearing Military/Government encryption equipment on the Black or
Network side at speeds up to and including 50 Mbps. The synchronous channels operate in steps of
8 Kbps. A front panel view of both the High Speed Synchronous Legacy Interface Module is shown in Figure 3-29.
HSL
OPNL
SYNC
BUFF
3-36
HSL
Figure 3-29. High Speed Synchronous Legacy Interface Module (HSL)
The High Speed Synchronous Legacy Interface Module performs the following primary functions:
•
Takes synchronous non-cell bearing traffic (Legacy traffic) and converts the data stream to
ATM CBR cells, adding the appropriate cell overhead
•
Takes the cells and places them onto the ATM cell bus
•
Monitors the physical synchronous interface for alarms
•
Collects statistics on module performance
CXUG
7-31-98
Cell Bus-Microprocessor-Power Section
The Cell Bus-Microprocessor-Power section of the High Speed Synchronous Legacy Interface
Module consists of the following:
•
ATM Cell Bus Switching Logic IC (ATM Cell Bus Switch), along with a RAM IC, provides connectivity to the backplane board
•
96-Pin DIN connector, used to connect onto the ATM Cell Bus
•
Intel 80C31 microprocessor
•
Capacitor filtering, provided for control and noise suppression
Unique Functionality Section
Unique functionality of the High Speed Legacy Interface Module includes:
•
Module equipped with one complete independent synchronous channel
•
Connector is a High Density DB-26 female type
•
Configured as a DCE device using a DB-26F high density connector
•
High-speed AAL1 segmentation and reassembly function process data speeds up to and including 50 Mbps at the user interface (CBR type)
A functional diagram of the Synchronous Legacy Interface Module is shown in Figure 3-30.
INTERFACE
DRIVERS & RECEIVERS
INTERFACE
DRIVERS & RECEIVERS
TYPE
FUNCTIONS
(AAL1)
MEMORY
ATM CELL
BUSS
SWITCH
SRAM
CPU 80C31
CXUG
7-31-98
Figure 3-30. High Speed Synchronous Legacy Interface Module Functional Diagram
3-37
Specifications
Port Capacity:
Media:
Electrical:
Connector:
Line Format:
Data Format:
Data Rates:
Timing:
One
Shielded Multi-twisted pair cable, low capacitance
EIA RS-530, DCE
HDB-26, Female
Balanced
ATM Cells
128 Kbps - 50 Mbps (in 8 Kbps increments)
Recovered Receive Timing
External Timing Reference
Diagnostics:
Internal
Facility Loopback
Terminal Loopback
Alarm – Surveillance: HEC
Compliance : ITU-T I.432, af-phy.0043.000
3-38
CXUG
7-31-98
Indicators
Type
LED
LED
LED
Label
OPNL
SYNC
BUFF
Color
Green
Red
Red
Meaning
Indicates that module has successfully received configuration from CPU and is operational
Off (normal) indicates synchronization with source; On indicates synchronization lost
Off (normal); On indicates clock synthesis buffer completely full or completely empty
Pinouts
Pinouts for the high speed DB-26 connector are shown in Figure 3-31 and the accompanying table.
Figure 3-31. HDB-26F (DCE) Pin Location
CXUG
7-31-98
3-39
3-40
Pin
1
4
5
6
2
3
11
12
13
9
10
7
8
Direction Signal
FG
SDA
RDA
RSA
CSA
DMA
SG
RRA
LL
TM
SDB
RDB
TTA
To HSL Module
Pin
14
15
16
17
18
19
24
25
26
20
21
22
23
Direction Signal
CSB
STA
DMB
RTA
RRB
TRB
TRA
TTB
RSB
STB
RL
RTB
KGRST
To Terminal
CXUG
7-31-98
Chapter
4
Operation
Initial Startup
On startup, the Cell Exchange will run through a short set of diagnostics, check for range errors in the current system configuration settings, and install the current system configuration (or the default configuration if range errors were detected).
Local Management Station
The Cell Exchange can be configured via a local VT100 emulation device (PC) connected via a null modem cable (See Appendix B for a description of the null modem cable.). Plug one end of the null modem cable into the PC serial port and the other into the port on the front of the CPU Module as shown in Figure 4-1.
CP U
Module
Null
Modem
Cable
CXUG
7-31-98
Figure 4-1. Local Cell Exchange—VT100 Connection
It is important that the emulation package is VT100 compatible, as ProComm or Windows terminal emulation software. The configuration environment makes use of attributes that are not always correctly emulated. The Cell Exchange will not be affected by missing reverse video in the display, but it can be tiring for the operator. Setup instructions for two terminal emulation
4-1
packages – Windows Terminal and Windows Hyper Terminal are described in the following paragraphs.
Windows Terminal Software
To configure the terminal.exe application, open the program and select the Settings menu, then
Terminal Emulation. When the emulation window opens, select DEC VT100 (ANSI). Select
Settings/Terminal Preferences. When that window opens, make the following choices:
•
Line Wrap
•
80 Column
•
Fonts: Check Fixedsys
•
Show Scroll Bar
•
Sound
•
Cursor: Check Block and Blink
•
Translation = None
•
Buffer lines = 100
Select Settings/Communications, and choose the following settings:
•
Baud Rate = 9600 bps
•
Parity = None
•
Flow Control = None
•
Data Bits = 8
•
Stop Bits = 1
•
Comm Port = 1 or 2 (depending on user configuration)
Windows Hyper Terminal Software
If using the Hyper Terminal application, open the program (Program Files/Accessories/ Hyper
Terminal). When the New Connection window opens, name it and select an icon (if desired), then click OK. On the next (Phone Number) screen, in the Connect using: box select Direct to Com 1
(or 2); click OK. When the COM 1 Properties window opens, choose the following settings:
•
Bits per second = 9600
•
Parity = None
•
Flow Control = None
•
Data Bits = 8
•
Stop Bits = 1
Click OK. When the Hyper Terminal window opens, select View/Font. In that window, choose the following:
•
Font = Terminal
•
Size = 10
•
Font Style = Regular
•
Script = OEM/DOS
The management system application runs within the Cell Exchange, using the terminal keyboard for input and the terminal screen for display. Pull down menus provide an easy to use environment.
Simply open the connection from the terminal screen and the window shown in Figure 4-2 will appear.
4-2
CXUG
7-31-98
LOGIN
Password: admin
TimePlex
®
Model CX-1500 Ver x.x-Date
Enter password
10:50 Login ************
Figure 4-2. Typical Logon Screen
Initial Logon
To access the Cell Exchange for configuration or software setup, the operator must first complete the logon procedures. The management system requires operators to logon with a password for the level of access desired. There is one password assigned to each access level. Passwords are assigned and controlled by the local system administrator.
If the logon screen is not displayed, or only partially displayed, refresh the screen by pressing
<ENTER> at the password entry prompt. Once the logon screen has repainted, the normal logon process can continue.
To logon:
1.
Power up the Local Management Station.
2.
Once the LMS has completed its internal startup procedures, call up the logon screen (see above).
3.
Follow the prompts on the screen.
4.
The default password is “admin.”
NOTE:
Once logged on, it is strongly recommended that the password be
changed as described in section "Changing Passwords.”
Logon Access Levels
Since various personnel will use the Cell Exchange, the management system allows three different levels of access. The following paragraphs describe the levels and the degree of access associated with each level.
Maintenance User - Able to login to view status and alarm conditions.
CXUG
7-31-98
4-3
Management User - Able to login to modify the configuration of the system in addition to maintenance user functions.
System Administrator - Able to login to set or change passwords in addition to all management and maintenance user functions.
Changing Passwords
Occasionally the system administrator or other authorized person may have to change passwords, due to the departure of personnel, compromise of the existing passwords, or some other reason. To change a password, select the Passwords command from the Configure menu. This will bring up the screen shown in Figure 4-3. Default passwords for each access level are shown.
Administrator Level Password:
Management Level Password:
Maintenance Level Password:
ADMIN
MANAGE
MAINTAIN
EXECUTE
09:57 CFG: Password
**ALARM**
*************
ESC-ESC = Previous
Figure 4-3. Password Menu
NOTE:
Only the administrator level can change passwords
1.
Highlight the password to be changed.
2.
Make the change.
3.
Select execute.
Menu Operation
Once logged on, the operator is automatically presented with the Main menu screen shown in
Figure 4-4. The Cell Exchange management system uses this menu-driven user interface for both operations and maintenance. The screen is divided into four sections: menu name, menu-specific selections, prompt line, and status line.
4-4
CXUG
7-31-98
Menu Name
Menu-Specific
Selections
Configure
Connect Mgmt
Multicast
Interface
Data/Time
Location Name
Admin Ports
System Timing
System Reset
Passwords
Software Ver
SNMP
View
Alarm Log
Module Status
Admin Info
Timing Source
Diagnostics
Loopback
Init Database
Save DB
Restore DB
Prompt Line
Status Line
10:50 Main Menu **ALARM** ************** 'Q' to Logout
Figure 4-4. Main Menu Screen
The menu name section is self-explanatory. The menu-specific section provides information or command selections relative to the menu that has been selected.
The prompt line is a user help function, containing information about the commands available for selection and the outcome of the selection. A prompt message will appear to show the user what information should be entered, or which key should be pressed, depending on the location of the cursor or the command selected.
The prompt line will also display alarm messages. When an alarm condition occurs or goes away, a brief message will be displayed. If multiple alarms occur, they will be queued and each message will be displayed for a very short time. When the last alarm message has timed out, the prompt line will revert to the help function.
The status line displays the current local time, the screen or menu name, alarm status, location name, and menu escape instructions where:
•
Time is displayed in 24-hour clock format (i.e., 2:30 PM is displayed as 14:30).
•
The screen/menu name area gives an indication of the path taken from the Main menu to the currently displayed screen. A colon is used to separate each element of the path.
•
The alarm status area tells the user if any alarms currently exist. If an alarm exists, the string
“**ALARM**” will be displayed. If no alarm exists, this area will be blank.
•
The location name area displays the user-assigned location name for each system.
•
The menu escape area displays the command required to exit the current screen. At the Main menu, the string “Q to Logout” is displayed. At any other menu or screen, the string “ESC-
ESC = Previous” is displayed.
Menu Selection
Within the Menu screen, the operator can move between menus by using the arrow keys or by
“quick key.” To use the arrows, simply press one of the left or right arrow keys. The menu selection will move left or right, and the new selection will highlight by displaying the menu name in reverse video and opening its command selections (drop down menu). If the current menu is the
CXUG
7-31-98
4-5
left-most menu and the left arrow is pressed, the display will “wrap” to the right-most selection.
The reverse is also true.
To use the “quick key” approach, press the key of the highlighted letter in each menu name.
Command Operation
From the Menu screen, the operator must perform the following steps to execute a command:
1.
Select the desired menu as the current menu.
2.
Use the arrow key or “quick key” to select the desired command.
3.
Select the command for execution by pressing <ENTER> or <F2> as shown on the prompt line.
Once a command is selected, it will be displayed in reverse video. To execute the command, simply press <ENTER>. The Command screen will now be displayed.
Moving around between commands is very similar to the menus, using the up and down arrow keys or a “quick key.” Using the arrow keys works exactly the same as for the menus, including the capability to wrap from top to bottom or vice versa. To use the “quick key,” press the key of the highlighted character in the command name.
Command Parameter Entry
Once a command is selected for execution, the operator will be prompted for all parameters associated with that command. For each required parameter, an entry area will be provided along with a prompt on the prompt line explaining the type of data required. As each parameter field is displayed, a default is provided. To select the default parameter, press the <ENTER> key before pressing any other key. Whenever possible, parameter selections will be made by toggle selections using the space key. This provides the operator with a consistent, user-friendly interface, and helps to limit out of range parameters. If numeric or ASCII text is required, the prompt line will show the valid range or number of ASCII characters allowed.
Regardless of the type of parameter, the entry process is ended by pressing the <ENTER> key. As each parameter is entered, validation checks are performed. If the entry is invalid, an error indication will be displayed on the status line. When the operator acknowledges the error by pressing the <ENTER> key, he/she will be prompted to enter a valid response before advancing to the next field. After a valid parameter has been entered, it will remain on the screen (if possible) until all parameters have been entered.
Keystroke Correction
To correct keystroke errors during command parameter entry, use the backspace key to erase the error, then reenter the correct information.
4-6
CXUG
7-31-98
Abort Command Key
The command parameter entry process can be ended at any time by pressing the <ESC> key twice
(<ESC><ESC>). This action will cancel command execution and return to the Menu screen.
Command Response
Commands executed by the Cell Exchange generally fall into two categories: commands that perform some process and commands that return status information. Commands that perform a process will usually return a completion code. This code is mapped into a completion status string that will be displayed on the status line. If an error is encountered during execution, the completion status string will be displayed in reverse video on the status line. If the command is executed successfully, the status string will be displayed in normal video.
Commands returning status information will only display a status string on the status line if an error occurred during execution. If execution is successful, the retrieved status information will be displayed in the command parameter window.
Main Menu
Menus are provided for Configure, View, and Diagnostics. Figure 4-5 shows the Main Menu with all submenus displayed for reference.
Configure
Connect Mgmt
Multicast
Interface
Data/Time
Location Name
Admin Ports
System Timing
System Reset
Passwords
Software Ver
SNMP
View
Alarm Log
Module Status
Admin Info
Timing Source
Diagnostics
Loopback
Init Database
Save DB
Restore DB
P r e s s E N T ER/F2 to go to the C o n n e c t i o n s M a n a g e m ent screen
10:50 Main Menu **ALARM** ******* ******* 'Q' to Logout
Figure 4-5. Main Menu Screen
Configure Menu
The Configure menu allows the operator to specify and update configuration parameters, and to set or display certain administrative information. This menu also allows the system administrator to assign or change passwords and access levels. Submenus include:
CXUG
7-31-98
4-7
4-8
Connection Management - This menu is described in section “Configuring Connections.”
Multicast – This menu item is not yet implemented.
Interface - This menu is described in section “Configuring Physical Interfaces.”
Date/Time - The Date/Time menu provides a means for setting or modifying the system parameters for date and time. When selected, the screen shown in Figure 4-6 will be displayed:
Year:
Month:
Day:
98
5
22
Hour:
Minute:
Second:
7
52
2
EXECUTE
Enter the year
07:52 CFG: Date/Time **ALARM**
**************
ESC-ESC = Previous
Figure 4-6. Date/Time Window from Configure Menu
Location Name - This menu is described in section "Setting Location Name.”
Admin Ports - This menu item is not yet implemented.
System Timing - This menu is described in section “Setting System Timing.”
System Reset - The System Reset menu provides a means to reboot the Cell Exchange system.
Selecting this menu item will bring up the window shown in Figure 4-7.
CXUG
7-31-98
RESET
R eboo t the system
9:32 DIAG: Clear Dbase **ALARM**
**************
ESC-ESC = Previous
Figure 4-7. System Reset Window from Configure Menu
Passwords - This menu is described in section “Changing Passwords.”
Software Ver - This menu is described in section “Software Versions.”
SNMP - This menu is described in section “Network Management.”
View Menu
The View menu allows the operator to display system parameters. Submenus include:
Alarm Log - This menu provides a description of the alarms and provides a timestamp.
Module Status - This menu provides a top-level view of what modules are installed in the Cell
Exchange system and defines their status. When you select this menu item, the screen shown in
Figure 4-8 is displayed.
Slot Number
9
10
11
12
7
8
5
6
13
14
15
--
--
1
2
3
4
Module Type
Dual Sync Cell
OC3 Cell
Dual Sync Leg
LSAL
Dual T1 Cell
DS3
SEL
Undefined
Hub-Router
OC3 Cell
High Speed Leg
Undefined
Undefined
STL
Undefined
Power A
Power B
Module Status
Up
Inactive
Inactive
Up
Inactive
Up
Down
N/ A
Up
Up
Up
N/ A
N/ A
Inactive
N/ A
Active
Inactive
P r e s s F 2 to show the intf status for the highlighted selection
9:32 View: Module Status
**ALARM**
**************
ESC-ESC = Previous
Figure 4-8. Module Status Window from View Menu
CXUG
7-31-98
4-9
The Module Status menu and associated windows are further described in the section “Statistics.”
Admin Info - This menu provides a summary of administrative information that has been previously entered in other screens. Selecting this menu item brings up the window shown in Figure
4-9.
Software Version:
Location:
Admin Phone Number:
Management Interface:
SNMP Read Community:
SNMP Write Community:
SNMP Trap Community:
Power Supply A:
Power Supply B: ver2.1
**************
**************
Craft Port
PUBLIC
SLIPRIVATE
PUBLIC
Active
Inactive
9:53
View: Admin Info
**ALARM**
**************
ESC-ESC = Previous
Figure 4-9. Admin Info Window from View Menu
Timing Source - This menu provides information on the source of the timing that is presently being used. Selecting this menu item brings up the window shown in Figure 4-10.
Timing Source Configured:
Timing Source in Service:
System Timing Source
Interface
--------------
Internal
Status
----
Rx/Tx Clock
--
REFRESH
Refresh this screen
14:17 View: SysTiming
**ALARM**
**************
ESC-ESC = Previous
Figure 4-10. Timing Source Window from View Menu
Diagnostics Menu
The Diagnostics menu allows the operator to access Cell Exchange diagnostic routines and database functions.
4-10
CXUG
7-31-98
Loopback: - This menu is described in “User-initiated Tests.”
Init Database - This menu provides the user with a means to clear the contents of the current database. Selecting this menu item brings up the screen shown in Figure 4-11.
EXECUTE
WARNING! Pressing F1/ENTER will clear all information out of the database.
11:13 DIAG: Clear Dbase
**ALARM**
**************
ESC-ESC = Previous
Figure 4-11. Initialize Database Window from Diagnostics Menu
Save DB - This menu allows the user to save the contents of the current database to a new file on the local management station.
NOTE:
The Save DB and Restore DB functions can only be executed in
Hyper Terminal. See section “Windows Hyper Terminal Software” for information on setting up a Hyper Terminal.
Selecting this menu item brings up the window shown in Figure 4-12.
CXUG
7-31-98
EXECUTE
Select 'Transfer: Capture Text', enter a NEW filename, then press F1/ENTER
11:18 DIAG: Save DB
**ALARM**
**************
ESC-ESC = Previous
Figure 4-12. Save Database Window from Diagnostics menu
4-11
From the Hyper Terminal menu, select Transfer, then Capture Text. Hyper Terminal will prompt for the name of the file in which the text will be stored.
NOTE:
It is very important to enter a NEW filename each time the database
is saved. If an old filename is used, the capture text operation will append the text to the file instead of overwriting its contents, and subsequent database restore operations will fail.
Once the new filename is entered, click Start and hit the <ENTER> key or F1 to send the contents of the database to the local management station. When the transfer is complete, the screen is cleared and the following prompt is displayed in the prompt line.
Select Transfer: Capture text: Stop then press ESC-ESC to exit
After the Capture Text is stopped, the save operation is complete and pressing ESC-ESC returns to the Main Menu.
Restore DB - This menu allows the user to restore the database from a previously saved file.
Selecting this menu item brings up the screen shown in Figure 4-13.
4-12
EXECUTE
Press F1/ENTER to restore the database from a file
11:24 DIAG: Restore DB **ALARM**
**************
ESC-ESC = Previous
Figure 4-13. Restore Database Window from Diagnostics Menu
Pressing the <F1> or <ENTER> key will begin the operation. The prompt line will change to
Select Transfer: Send Text File, enter the file name, and click Open
Once the Transfer/Send Text File is selected, the restore operation will begin. (Note that the Send
File menu option cannot be used for the Database Restore function.) Database restoration will take from about 10 seconds to about 1 minute, depending on the contents of the file. During this operation, no feedback is provided to the user.
When the transfer is completed, the Cell Exchange will be rebooted to ensure that any needed database conversion will be performed.
CXUG
7-31-98
If an error is detected during the Database Restore operation, the database will be completely cleared. Errors can arise from any of the following conditions:
•
Checksum error (each database file contains a checksum over the data).
•
Invalid database file format detected.
•
Database version not supported.
Alarms
Alarm messages are displayed on the prompt line. When an alarm condition occurs or clears, a brief message appears, lasting about 5 seconds. At the same time, the string “**ALARM**” appears in the status line. This string will remain until all alarms are cleared. If multiple alarms occur simultaneously, the alarms will be queued up, and each alarm message will only be displayed for about 1/2 second. The last message in the queue will be displayed for the full 5 seconds, assuming no new alarms occur. When the last alarm message has been displayed and has timed out, the prompt line will revert to its user help display.
An alarm message has priority over other prompt line messages. Therefore, if an alarm message is being displayed, and the user moves the cursor, the alarm message will remain for the full 5 seconds before displaying the help prompt for the new cursor position.
Module Statistics
The Cell Exchange system collects and displays performance statistics for each of its installed modules. To view the statistics for a given interface module, select Module Status from the View menu. The window shown in Figure 4-14 will appear.
Slot Number
11
12
13
8
9
10
14
15
--
--
5
6
7
3
4
1
2
Module Type
Dual Sync Cell
OC3 Cell
Dual Sync Leg
LSAL
Dual T1 Cell
DS3
SEL
Undefined
Hub-Router
OC3 Cell
High Speed Leg
Undefined
Undefined
STL
Undefined
Power A
Power B
Module Status
N/A
Up
Up
Up
N/A
N/A
Up
Inact ive
Inact ive
Up
Inact ive
Up
Down
Inact ive
N/A
Active
Inact ive
P r e s s F 2 t o s h o w the intf s t a t u s f o r t h e h i g h l i g h t e d s e l e c t i o n
9:32 View: Module Status
**ALARM**
**************
ESC-ESC = Previous
Figure 4-14. Module Status Window
CXUG
7-31-98
4-13
This window provides a top-level view of the hardware installed in the chassis. Information is available for each slot, including module type and module status. More information can be obtained for a particular module by highlighting the module and pressing <F2>. This action will bring up the logical interface screen shown in Figure 4-15.
Intf Name
Walkersville
Intf Type
Dual T1 Cell
Slot
5
Physical Intf
A
Inact Intf Status
Up
SCROLL UP LINE
SCROLL UP PAGE
Press F2 to go to the specific interface screen
09:52 View: Intf Status **ALARM**
SCROLL DOWN LINE
SCROLL DOWN PAGE
******************
ESC-ESC = Previous
Figure 4-15. Logical Interface Status Window
The logical interface status window displays status information for each logical interface defined for a specific module. In addition to configuration information (name, slot, port, active), the status of the interface is shown. This represents a snapshot of the current state of the interface – up or down. Additional information for each logical interface can be obtained by highlighting the interface and pressing <F2>. The screen shown in Figure 4-16 will appear.
Intf Name: Hyattsburg
Card Status:
Interface Status:
Loopback:
Up
Up
No
Slot: 14 Intf: A Intf Type: Structured T1
STL->ATM Cells:
HEC Error Cells:
Misrouted Cells:
STL<-ATM Cells:
Lost CLP Cells:
Lost non-CLP Cells:
0
0
0
0
0
0
Last Statistics
Reset Hour: 13:00
REFRESH CLEAR
HISTORY
16:25 View: Intf Status **ALARM**
**********
ESC-ESC = Previous
4-14
Figure 4-16. Specific Interface Window
The specific interface screen contains information that is tailored to the interface. The sample above represents a Structured T1 Legacy interface module.
CXUG
7-31-98
Dual T-1 Cell Interface Module
To view the statistics for the Dual T-1 Cell Interface Module, select Module Status from the View menu.
The window that appears provides a top-level view of the hardware installed in the chassis.
Information is available for each slot, including module type and module status. More information can be obtained for a particular module by highlighting the module and pressing <F2>. This action will bring up the logical interface screen shown in Figure 4-17.
Intf Name
Walkersville
Intf Type
Dual T1 Cell
Slot:
5
Physical Intf
A Up
SCROLL UP LINE
SCROLL UP PAGE
Press ENETR/F2 to go to the interface statistics screen
15:17 View: Intf Status
**ALARM**
**********
SCROLL DOWN LINE
SCROLL DOWN PAGE
ESC-ESC = Previous
Figure 4-17. Logical Interface Status Window—Dual T1 Cell
The logical interface status window displays status information for each logical interface defined for a specific module. In addition to configuration information (name, slot, port, active), the status of the interface is shown. This represents a snapshot of the current state of the interface – up or down. Additional information for each logical interface can be obtained by highlighting the interface and pressing <F2>. The screen shown in Figure 4-18 will appear. This screen contains information that is tailored to the interface.
CXUG
7-31-98
4-15
4-16
Intf Name: Walkersville
Card Status:
Interface Status:
Loopback:
Up
Up
No
Slot: 5 Intf: A Intf Type: Dual T1 Cell
T1C->ATM Cells:
HEC Error Cells:
Misrouted Cells:
T1C<-ATM Cells:
Lost CLP Cells:
0
0
Lost non-CLP Cells: 0
0
0
0
Last Statistics
Reset Hour: 13:00
REFRESH CLEAR
HISTORY
14:52 View: Intf Status **ALARM**
**********
ESC-ESC = Previous
Figure 4-18. Specific Interface Window—Dual T1 Cell
To view module activity for the past 8 hours, select the <HISTORY> button and press
<ENTER>. This will bring up the screen shown in Figure 4-19.
Intf Name:
Period
Walkersville
01:00 - 02:00
02:00 - 03:00
03:00 - 04:00
04:00 - 05:00
05:00 - 06:00
06:00 - 07:00
07:00 - 08:00
08:00 - 09:00
Slot: 5
T1C->ATM
910
908
912
912
910
912
908
910
Intf: A Intf Type: Dual T1 Cell
T1C<-ATM
910
908
912
912
910
912
908
910
Note: Above statistics show total number of cells in each hour interval
(HEC), non-matching VPI/VCI (misrouted) and congestion.
14:52 View: Intf Status **ALARM**
**********
ESC-ESC = Previous
Figure 4-19. Interface Statistics Window—Dual T1 Cell
The column on the left shows the period in which the measurement was taken. The other two columns show the number of cells passed in each direction through the interface.
CXUG
7-31-98
OC-3 Cell Interface Module
To view the statistics for the OC-3 Cell Interface Module, select Module Status from the View menu.
The window that appears provides a top-level view of the hardware installed in the chassis.
Information is available for each slot, including module type and module status. More information can be obtained for a particular module by highlighting the module and pressing <F2>. This action will bring up the logical interface screen shown in Figure 4-20.
Intf Name
Germantown
Intf Type
OC3 Cell
Slot:
2
Physical Intf Inact
A
Intf Status
Up
SCROLL UP LINE
SCROLL UP PAGE
Press ENETR/F2 to go to the interface statistics screen
15:17 View: Intf Status **ALARM**
**********
SCROLL DOWN LINE
SCROLL DOWN PAGE
ESC-ESC = Previous
Figure 4-20. Logical Interface Status Window—OC3 Cell
The logical interface status window displays status information for each logical interface defined for a specific module. In addition to configuration information (name, slot, port, active), the status of the interface is shown. This represents a snapshot of the current state of the interface – up or down. Additional information for each logical interface can be obtained by highlighting the interface and pressing <F2>. The screen shown in Figure 4-21 will appear. This screen contains information that is tailored to the interface.
CXUG
7-31-98
4-17
4-18
Intf Name: Germantown
Card Status:
Interface Status:
Loss of Frame:
Loss of Signal:
Loss of Pointer:
(Alarm Indica- Path AIS: tion Signal) Line AIS:
(Remote Failure Path RFI:
Indication) Line RFI:
Path Trace Mismatch:
Signal Label Mismatch:
Loss of Cell Delineation:
Loopback:
Up
Up
CLR
CLR
CLR
CLR
CLR
CLR
CLR
CLR
CLR
CLR
No
REFRESH
Slot: 2
CLEAR
Intf: A Intf Type: OC3 Cell
OC3->ATM Cells:
HEC Error Cells:
Misrouted Cells:
OC3<-ATM Cells:
Lost CLP Cells:
0
0
Lost non-CLP Cells: 0
0
0
0
Last Statistics
Reset Hour: 11:00
HISTORY
12:25 View: Intf Status **ALARM**
**********
ESC-ESC = Previous
Figure 4-21. Specific Interface Window—OC3 Cell
To view module activity for the past 8 hours, select the <HISTORY> button and press
<ENTER>. This will bring up the screen shown in Figure 4-22.
Intf Name: Germantown
Period
01:00 - 02:00
02:00 - 03:00
03:00 - 04:00
04:00 - 05:00
05:00 - 06:00
06:00 - 07:00
07:00 - 08:00
08:00 - 09:00
Slot: 2
OC3->ATM
910
908
912
912
910
912
908
910
Intf: A Intf Type: OC3 Cell
OC3<-ATM
910
908
912
912
910
912
908
910
Note: Above statistics show total number of cells in each hour interval
(HEC), non-matching VPI/VCI (misrouted) and congestion.
12:28 View: Intf Status **ALARM**
**********
ESC-ESC = Previous
Figure 4-22. Interface Statistics Window—OC3 Cell
The column on the left shows the period in which the measurement was taken. The other two columns show the number of cells passed in each direction through the interface.
CXUG
7-31-98
Dual Synchronous Cell Interface Module
To view the statistics for the Dual Synchronous Cell Interface Module, select Module Status from the View menu.
The window that appears provides a top-level view of the hardware installed in the chassis.
Information is available for each slot, including module type and module status. More information can be obtained for a particular module by highlighting the module and pressing <F2>. This action will bring up the logical interface screen shown in Figure 4-23.
Intf Name
Frederick
Intf Type Slot:
Dual Sync Cell 1
Physical Intf Inact
A
Intf Status
Up
SCROLL UP LINE
SCROLL UP PAGE
Press ENETR/F2 to go to the interface statistics screen
15:17 View: Intf Status **ALARM**
**********
SCROLL DOWN LINE
SCROLL DOWN PAGE
ESC-ESC = Previous
Figure 4-23. Logical Interface Status Window—Dual Sync Cell
The logical interface status window displays status information for each logical interface defined for a specific module. In addition to configuration information (name, slot, port, active), the status of the interface is shown. This represents a snapshot of the current state of the interface – up or down. Additional information for each logical interface can be obtained by highlighting the interface and pressing <F2>. The screen shown in Figure 4-24 will appear. This screen contains information that is tailored to the interface.
CXUG
7-31-98
4-19
4-20
Intf Name: Fredereick
Card Status:
Interface Status:
Lossof Cell Sync:
Loopback:
Up
Up
CLR
No
Slot: 1 Intf: A Intf Type: Dual Sync Cell
DSC->ATM Cells:
HEC Error Cells:
MisroutedCells:
DSC<-ATM Cells:
Lost CLP Cells:
Lostnon-CLP Cells:
0
0
0
0
0
0
Last Statistics
Reset Hour: 10:00
REFRESH CLEAR
HISTORY
12:25 View: Intf Status **ALARM**
**********
ESC-ESC = Previous
Figure 4-24. Specific Interface Window—Dual Sync Cell
To view module activity for the past 8 hours, select the <HISTORY> button and press
<ENTER>. This will bring up the screen shown in Figure 4-25.
Intf Name: Frederick
Period
01:00 - 02:00
02:00 - 03:00
03:00 - 04:00
04:00 - 05:00
05:00 - 06:00
06:00 - 07:00
07:00 - 08:00
08:00 - 09:00
Slot: 1
DSC->ATM
910
908
912
912
910
912
908
910
Intf: A Intf Type: Dual Sync Cell
DSC<-ATM
910
908
912
912
910
912
908
910
Note: Above statistics showtotalnumber of cells in eachhour interval
(HEC), non-matching VPI/VCI (misrouted) and congestion.
12:28 View: Intf Status **ALARM**
**********
ESC-ESC = Previous
Figure 4-25. Interface Statistics Window—Dual Sync Cell
The column on the left shows the period in which the measurement was taken. The other two columns show the number of cells passed in each direction through the interface.
CXUG
7-31-98
DS-3 Cell Interface Module
To view the statistics for the DS-3 Cell Interface Module, select Module Status from the View menu.
The window that appears provides a top-level view of the hardware installed in the chassis.
Information is available for each slot, including module type and module status. More information can be obtained for a particular module by highlighting the module and pressing <F2>. This action will bring up the logical interface screen shown in Figure 4-26.
Intf Name
Urbana
Intf Type
DS3
Slot:
6
Physical Intf
A
Inact Intf Status
Up
SCROLL UP LINE
SCROLL UP PAGE
Press ENETR/F2 to go to the interface statistics screen
15:17 View: Intf Status **ALARM**
**********
SCROLL DOWN LINE
SCROLL DOWN PAGE
ESC-ESC = Previous
Figure 4-26. Logical Interface Status Window—DS3
The logical interface status window displays status information for each logical interface defined for a specific module. In addition to configuration information (name, slot, port, active), the status of the interface is shown. This represents a snapshot of the current state of the interface—up or down. Additional information for each logical interface can be obtained by highlighting the interface and pressing <F2>. The screen shown in Figure 4-27 will appear. This screen contains information that is tailored to the interface.
CXUG
7-31-98
4-21
4-22
Intf Name: Urbana
Card Status:
Interface Status:
Up
Up
Loss of Cell Sync:
Loss of Frame:
Loss of Signal:
Loss of Cell Delineation:
Loopback:
CLR
CLR
CLR
CLR
No
Slot: 6 Intf: A Intf Type: DS3
DS3->ATM Cells:
HEC Error Cells:
0
0
Misrouted Cells:
DS3<-ATM Cells:
Lost CLP Cells:
Lost non-CLP Cells:
0
0
0
0
Last Statistics
Reset Hour: 10:00
REFRESH CLEAR
HISTORY
12:25 View: Intf Status **ALARM**
**********
ESC-ESC = Previous
Figure 4-27. Specific Interface Window—DS3
To view module activity for the past 8 hours, select the <HISTORY> button and press
<ENTER>. This will bring up the screen shown in Figure 4-28.
Intf Name: Urbana
Period
01:00 - 02:00
02:00 - 03:00
03:00 - 04:00
04:00 - 05:00
05:00 - 06:00
06:00 - 07:00
07:00 - 08:00
08:00 - 09:00
Slot: 6
DS3->ATM
910
908
912
912
910
912
908
910
Intf: A Intf Type: DS3
DS3<-ATM
910
908
912
912
910
912
908
910
Note: Above statistics show total number of cells in each hour interval
(HEC), non-matching VPI/VCI (misrouted) and congestion.
12:28 View: Intf Status **ALARM**
**********
ESC-ESC = Previous
Figure 4-28. Interface Statistics Window—DS3
The column on the left shows the period in which the measurement was taken. The other two columns show the number of cells passed in each direction through the interface.
CXUG
7-31-98
Structured T-1 Legacy Module
To view the statistics for the Structured T-1 Legacy Module, select Module Status from the View menu.
The window that appears provides a top-level view of the hardware installed in the chassis.
Information is available for each slot, including module type and module status. More information can be obtained for a particular module by highlighting the module and pressing <F2>. This action will bring up the logical interface screen shown in Figure 4-29.
Intf Name
Hyattsburg
Intf Type
STL
Slot:
14
Physical Intf
A Up
SCROLL UP LINE
SCROLL UP PAGE
Press ENETR/F2 to go to the interface statistics screen
15:17 View: Intf Status
**ALARM**
**********
SCROLL DOWN LINE
SCROLL DOWN PAGE
ESC-ESC = Previous
Figure 4-29. Logical Interface Status Window—STL
The logical interface status window displays status information for each logical interface defined for a specific module. In addition to configuration information (name, slot, port, active), the status of the interface is shown. This represents a snapshot of the current state of the interface—up or down. Additional information for each logical interface can be obtained by highlighting the interface and pressing <F2>. The screen shown in Figure 4-30 will appear. This screen contains information that is tailored to the interface.
CXUG
7-31-98
4-23
4-24
Intf Name: Hyattsburg
Card Status: Up
Interface Status:
Loopback:
Up
No
Slot: 14 Intf: A Intf Type: Structured T1
STL->ATM Cells: 0
HEC Error Cells:
Misrouted Cells:
STL<-ATM Cells:
Lost CLP Cells:
Lost non-CLP Cells:
0
0
0
0
0
Last Statistics
Reset Hour: 13:00
REFRESH CLEAR
HISTORY
16:25 View: Intf Status **ALARM**
**********
ESC-ESC = Previous
Figure 4-30. Specific Interface Window—Structured T1
To view module activity for the past 8 hours, select the <HISTORY> button and press
<ENTER>. This will bring up the screen shown in Figure 4-31.
Intf Name: Hyattsburg
Period
01:00 - 02:00
02:00 - 03:00
03:00 - 04:00
04:00 - 05:00
05:00 - 06:00
06:00 - 07:00
07:00 - 08:00
08:00 - 09:00
Slot: 14
STL->ATM
910
908
912
912
910
912
908
910
Intf: A Intf Type: Structured T1
STL<-ATM
910
908
912
912
910
912
908
910
Note: Above statistics show total number of cells in each hour interval
(HEC), non-matching VPI/VCI (misrouted) and congestion.
16:28 View: Intf Status **ALARM**
**********
ESC-ESC = Previous
Figure 4-31. Interface Statistics Window—Structured T1
The column on the left shows the period in which the measurement was taken. The other two columns show the number of cells passed in each direction through the interface.
CXUG
7-31-98
Synchronous Legacy Interface Module
To view the statistics for the Synchronous Legacy Interface Module, select Module Status from the View menu.
The window that appears provides a top-level view of the hardware installed in the chassis.
Information is available for each slot, including module type and module status. More information can be obtained for a particular module by highlighting the module and pressing <F2>. This action will bring up the logical interface screen shown in Figure 4-32.
Intf Name
Gaithersburg
Intf Type Slot:
Dual Sync Leg 3
Physical Intf
A Up
SCROLL UP LINE
SCROLL UP PAGE
Press ENETR/F2 to go to the interface statistics screen
13:37 View: Intf Status **ALARM**
**********
SCROLL DOWN LINE
SCROLL DOWN PAGE
ESC-ESC = Previous
Figure 4-32. Logical Interface Status Window—Dual Sync Leg
The logical interface status window displays status information for each logical interface defined for a specific module. In addition to configuration information (name, slot, port, active), the status of the interface is shown. This represents a snapshot of the current state of the interface – up or down. Additional information for each logical interface can be obtained by highlighting the interface and pressing <F2>. The screen shown in Figure 4-33 will appear. This screen contains information that is tailored to the interface.
CXUG
7-31-98
4-25
4-26
Intf Name: Gaithersburg
Card Status:
Interface Status:
Loopback:
Up
Up
No
Slot: 3 Intf: A Intf Type: Dual Sync Leg
DSL->ATM Cells:
HEC Error Cells:
Misrouted Cells:
DSL<-ATM Cells:
Lost CLP Cells:
Lost non-CLP Cells:
0
0
0
0
0
0
Last Statistics
Reset Hour: 11:00
REFRESH CLEAR
HISTORY
13:40 View: Intf Status **ALARM**
**********
ESC-ESC = Previous
Figure 4-33. Specific Interface Window—Dual Sync Leg
To view module activity for the past 8 hours, select the <HISTORY> button and press
<ENTER>. This will bring up the screen shown in Figure 4-34.
Intf Name: Gaithersburg
Period
01:00 - 02:00
02:00 - 03:00
03:00 - 04:00
04:00 - 05:00
05:00 - 06:00
06:00 - 07:00
07:00 - 08:00
08:00 - 09:00
Slot: 3
DSL->ATM
910
908
912
912
910
912
908
910
Intf: A Intf Type: Dual Sync Leg
DSL<-ATM
910
908
912
912
910
912
908
910
Note: Above statistics show total number of cells in each hour interval
(HEC), non-matching VPI/VCI (misrouted) and congestion.
14:28 View: Intf Status **ALARM**
**********
ESC-ESC = Previous
Figure 4-34. Interface Statistics Window—Dual Sync Leg
The column on the left shows the period in which the measurement was taken. The other two columns show the number of cells passed in each direction through the interface.
CXUG
7-31-98
High-Speed Synchronous Legacy Interface Module
To view the statistics for the High-Speed Synchronous Legacy Interface Module, select Module
Status from the View menu.
The window that appears provides a top-level view of the hardware installed in the chassis.
Information is available for each slot, including module type and module status. More information can be obtained for a particular module by highlighting the module and pressing <F2>. This action will bring up the logical interface screen shown in Figure 4-35.
Intf Name
Rockville
Intf Type Slot:
High SpeedSync Leg 11
Physical Intf
A Up
SCROLL UP LINE
SCROLL UP PAGE
Press ENETR/F2 to go to the interface statistics screen
07:50 View: Intf Status **ALARM**
**********
SCROLL DOWN LINE
SCROLL DOWN PAGE
ESC-ESC = Previous
Figure 4-35. Logical Interface Status Window
The logical interface status window displays status information for each logical interface defined for a specific module. In addition to configuration information (name, slot, port, active), the status of the interface is shown. This represents a snapshot of the current state of the interface – up or down. Additional information for each logical interface can be obtained by highlighting the interface and pressing <F2>. The screen shown in Figure 4-36 will appear. This screen contains information that is tailored to the interface.
CXUG
7-31-98
4-27
4-28
Intf Name: Rockville
Card Status: Up
Interface Status:
Loopback:
Up
No
Slot: 11 Intf: A Intf Type: High SpeedSync Leg
HSL->ATM Cells: 0
HEC Error Cells:
Misrouted Cells:
HSL<-ATM Cells:
Lost CLP Cells:
Lost non-CLP Cells:
0
0
0
0
0
Last Statistics
Reset Hour: 23:00
REFRESH CLEAR
HISTORY
08:01 View: Intf Status **ALARM**
**********
ESC-ESC = Previous
Figure 4-36. Specific Interface Window—High-Speed Sync Leg
To view module activity for the past 8 hours, select the <HISTORY> button and press
<ENTER>. This will bring up the screen shown in Figure 4-37.
Intf Name: Rockville
Period
01:00 - 02:00
02:00 - 03:00
03:00 - 04:00
04:00 - 05:00
05:00 - 06:00
06:00 - 07:00
07:00 - 08:00
08:00 - 09:00
Slot: 11
HSL->ATM
910
908
912
912
910
912
908
910
Intf: A Intf Type: High Speed Sync Leg
HSL<-ATM
910
908
912
912
910
912
908
910
Note: Above statistics show total number of cells in each hour interval
(HEC), non-matching VPI/VCI (misrouted) and congestion.
08:02 View: Intf Status **ALARM**
**********
ESC-ESC = Previous
Figure 4-37. Interface Statistics Window—High-Speed Sync Leg
The column on the left shows the period in which the measurement was taken. The other two columns show the number of cells passed in each direction through the interface.
CXUG
7-31-98
Chapter
5
Configuration
The configuration parameters for the Cell Exchange systems are stored on each module in batterybacked memory. This means that the configuration will remain unchanged even if power is removed from the unit. When power is restored, all configuration parameters previously set still reside in memory and the system will return to that configuration.
Initial configuration is normally accomplished in four steps:
1.
Set location name.
2.
Configure physical interfaces.
3.
Select system timing source.
4.
Configure connections.
These steps are further explained in the following paragraphs.
Setting Location Name
To set the location name, select the appropriate command from the Configure menu, Figure 5-1.
Configure
Connect Mgmt
Multicast
Interface
Data/Time
Location Name
Admin Ports
System Timing
System Reset
Passwords
Software Ver
SNMP
View
Diagnostics
Press ENTER/F2 to go to the Location Name scre en
10:50 Main Menu **ALARM** ************** 'Q' to Logout
Figure 5-1. Configure Menu – Location Name
This action will bring up the screen shown in Figure 5-2.
CXUG
7-31-98
5-1
Location Name:
Admin Phone Number:
EXECUTE
Press ENTE R To update the config database and return to the Main Menu
09:57 CFG: Location Name **ALARM** ************** ESC-ESC = Previous
Figure 5-2. Location Name Screen
Using the <TAB> or <ARROW> keys, move to the Location Name field and enter the location. If desired, move to the Admin Phone Number field and enter the phone number of the point of contact for that location. When done, move to the <EXECUTE> button and press <ENTER> to save the entries and return to the main menu.
Configuring Physical Interfaces
To configure the interfaces for the Cell Exchange system, select the Interface command from the
Configure menu, Figure 5-3.
Configure
Connect Mgmt
Multicast
Interface
Data/Time
Location Name
Admin Ports
System Timing
System Reset
Passwords
Software Ver
SNMP
View
Diagnostics
Press ENTER/F2 to go to the Interface screen
10:50 Main Menu **ALARM** ************** 'Q' to Logout
Figure 5-3. Configure Menu – Interface
5-2
CXUG
7-31-98
This will bring up the screen shown in Figure 5-4.
Text
Intf Name
Walkersville
Emmitsburg
Germantown
Frederick
Gaithersburg
Rockville
Urbana
Hyattsburg
Middletown
Bethesda
Darnestown
Tumbler Tumbler
Intf Type
Dual T1 Cell
OC3 Cell
OC3 Cell
Dual Sync Cell
Dual Sync Leg
High Speed Leg
DS3
STL
SEL
Hub-Router
LSAL
Slot
9
4
5
10
2
1
3
11
6
14
7
Toggle Toggle
Physical Intf
A
B
A
A
A
A
A
B
A
A
B
Inact
*
*
*
*
SCROLL UP LINE
SCROLL UP PAGE
EXECUTE
UPDATE
Press ENTER To update the config database and return to the Main Menu
09:52 CFG: Interface **ALARM** ******************
SCROLL DOWN LINE
SCROLL DOWN PAGE
ESC-ESC = Previous
Figure 5-4. Interface Menu
For initial configuration, this screen will be blank; each interface will need to be entered. See
Figure 5-5.
Intf Name
Walkersville
Intf Type Slot Physical Intf Inact
CXUG
7-31-98
SCROLL UP LINE
SCROLL UP PAGE
F1— E xecute
EXECUTE
F2 — G oto Configure
UPDATE
F3 — Add Interface
SCROLL DOWN LINE
SCROLL DOWN PAGE
F4 — Delete Interfac e
Enter an alphanumeric string with a max of 14 characters
09:52 CFG: Interface **ALARM** ******************
ESC-ESC = Previous
Figure 5-5. Entering Interface Information
NOTE:
For all menus, selecting the <UPDATE> button and pressing
<ENTER> will update the active configuration and remain in the
submenu. Selecting <EXECUTE> and pressing <ENTER> will update the configuration information and return to the main menu.
5-3
1.
Using the up <ARROW> key, move the cursor to the Intf Name field, press F3, and enter the name of the interface. The interface name can be up to 14 characters in length and is used as the interface reference name throughout the management system.
2.
Tab to the Intf Type field and select the type of interface module installed. This is a tumbler field; pressing the <SPACE> bar will move through the choices available.
3.
Tab to the Slot field and select the physical slot in which the module is installed. This is a tumbler field; pressing the <SPACE> bar will move through the slot numbers sequentially.
4.
Tab to the Physical Intf field and, using the <SPACE> bar, toggle to the interface port for this connection.
5.
Tab to the Inact field and, using the <SPACE> bar, toggle to select active or inactive status for this interface. Active status is blank, inactive status is marked with an asterisk (*).
6.
Press <F1> to enter the interface information. After a short delay, the OPNL LED on the front of the affected module should illuminate, indicating that the module has successfully received configuration information from the CPU and has booted up.
7.
Enter as many interfaces as needed by using the <F3> key to add interfaces.
8.
For detailed configuration of the interface, press <F2>. This will bring up the screen shown in
Figure 5-6.
NOTE:
The information required on each screen will differ depending upon the type of interface module selected.
Intf Name: Walkersville Slot: 5
Framing: ESF
Coding: B8ZS
Line Build Out/Equal: 0
Scramble Cells: Enable
Tx Clock Out: Recovered
EXECUTE
Intf: A Intf Type: Dual T1 Cell
Press ENTER To update the config database and return to the Main Menu
09:52 CFG: Con Mgmt: Map **ALARM**
**********
ESC-ESC = Previous
5-4
Figure 5-6. Detailed Interface Configuration (Dual T1 Cell Interface)
9.
Enter appropriate information. (This screen shows the information required for a T1 cell interface.) a.
Using the <TAB> or <ARROW> key, move to the framing mode. This is a toggle field, press the <SPACE> bar to move through the available choices.
CXUG
7-31-98
CXUG
7-31-98 b.
Using the <TAB> or <ARROW> key, move to the coding field. This is also a toggle field, press the <SPACE> bar to move through the selections.
c.
Using the <TAB> or <ARROW> key, move to the Line Build
Out/Equalization field, and toggle through the available choices.
d.
Using the <TAB> or <ARROW> key, move to the BER Alarm Threshold field and select the appropriate bit error rate. This is a toggle field. When an error rate in excess of the threshold occurs, it is considered a “Major Alarm.” e.
Using the <TAB> or <ARROW> key, move to the Scramble Cells field and select the ATM cell scrambler. This is a two-position toggle field: Enable or
Disable.
f.
Using the <TAB> or <ARROW> key, move to the transmit clock source.
This is a toggle field, press the <SPACE> bar to move through the selections.
g.
To enter all the selected parameters on the screen, either move to the
<EXECUTE> block and press <ENTER >. This will enter the parameters in the database and return to the Main Menu.
10.
To delete an interface (Figure 5-5), move the cursor to the appropriate line and press <F4>.
Deleting an interface will delete the interface parameter settings. VPI/VCI connection settings associated with the deleted interfaces will also be deleted.
11.
When all entries are complete, move to the <UPDATE> button and press <ENTER> to update the active configuration information, or use the <EXECUTE> button to update and return to the main menu. Changes take effect immediately upon execution.
5-5
Setting System Timing
To select the timing reference for the Cell Exchange systems, select the System Timing command from the Main Menu. This will bring up the screen shown in Figure 5-7.
Reference Interface:
Reference Clock on Interface:
******************
***************
EXECUTE
S elect interface for system tim ing re fere nce
09:57 CFG: Location Name **ALARM** ************** ESC-ESC = Previous
Figure 5-7. System Timing Window
1.
Move the cursor to the Reference Interface field. This is a toggle field. Pressing the <SPACE> bar will move between the available selections.
2.
Tab to Reference Clock on Interface field. This is also a toggle field. Pressing the <SPACE> bar will move between selections.
3.
When done, tab or arrow to the <EXECUTE> button and press <ENTER> to save and execute the system timing references.
Software Versions
When the user receives a new version of software (initially distributed on a diskette), it is uploaded using terminal emulation software, running on a PC with serial communication port connected to the Craft port via a RS232 null modem cable. On the PC, the user issues DOS command:\> a:<filename>, which will expand the software from the floppy disk in drive A: into the current directory on the hard drive.
The user will then:
1.
Log into the Cell Exchange system and select 'Software Ver' on the main menu shown in
Figure 5-8.
5-6
CXUG
7-31-98
Configure
Connect Mgmt
Multicast
Interface
Data/Time
Location Name
Admin Ports
System Timing
System Reset
Passwords
Software Ver
SNMP
View
Diagnostics
Press ENT ER /F2 to go to the Software Version configuration screen
10:50 Main Menu **ALARM** ************** 'Q' to Logout
Figure 5-8. Software Version Command
2.
Enter the name of the new version (supplied with the diskette) as show in Figure 5-9.
New Version Name:
Versions Currently Loaded in the System operating
LOAD
CXUG
7-31-98
UPDATE
En ter a name to identify th is version of the a pp lica tion code
09:52 CFG:Software Ver **ALARM** ******************
ESC-ESC = Previous
Figure 5-9. Software Version Selection Screen
3.
Select <LOAD> and press <ENTER>. Observe that the Main Menu screen is repainted. The time of day display will freeze, which is an indication that the upload is in progress.
4.
On the terminal emulation toolbar, Click 'Transfer' function and select 'Send ASCII' or
'Send Text' on the drop-down menu.
5.
When the dialog box appears, fill in the file name installed previously from the floppy diskette
(<filename>.hex) and click OK, or Open.
6.
This will load the new software version. The process takes approximately 35 minutes. After the upload is done, the main menu will come back on.
5-7
7.
Select 'Software' and observe that the new version is displayed on the screen.
8.
If the new version is to be used, select 'Software Ver' on the main menu and move the cursor to select the new version.
9.
Press the <F2> function key. After a short delay, the new version will load into the CPU and, subsequently, to all installed interface modules.
10.
Other versions of the software are selected and made active in the same manner.
Configuring Interface Connections
The final step in the configuration process is to set up the connections for each interface. Select the
Connection Mgmt command from the Configure menu. This will bring up the screen shown in
Figure 5-10.
Intf Name
Walkersville
Emmitsburg
Intf Type
Dual T1 Cell
Structured T1
Slot
5
10
Physical Intf
A
A
Inact
*
SCROLL UP LINE
SCROLL UP PAGE
SCROLL DOWN LINE
SCROLL DOWN PAGE
Press F2 to g o to the conn ection ma p for the high ligh ted selection
09:52 CFG: Con Mgmt **ALARM** ******************
ESC-ESC = Previous
Figure 5-10. Connection Management Window
To configure the connections, move the cursor to highlight one of the interfaces. Press <F2> or
<ENTER> to bring up the connection management map for that interface (Figure 5-11).
5-8
CXUG
7-31-98
Name: Emmitsburg
Inact VPI VCI Dir
Slot: 5
Interface Name
Intf: A
VPI
Type: Dual T1 Cell
VCI Chan Connection Name Priority
CXUG
7-31-98
SCROLL UP LINE
SCROLL UP PAGE
EXECUTE UPDATE
SCROLL DOWN LINE
SCROLL DOWN PAGE
Press ENTER to update the config database a nd return to the Main M enu
09:52 CFG: Con Mgmt:Map **ALARM** ****************** ESC-ESC = Previous
Figure 5-11. Configuration Management Mapping Menu
This screen shows the connection mapping for the selected interface (Dual T1 Cell Interface).
Moving the cursor to the affected line enters connection data for each interface.
1.
Position cursor in the Inact field. This is a toggle field, press the <SPACE> bar to toggle between active (blank) or inactive (*) modes.
2.
Tab to the VPI field for the input interface and enter the appropriate value. VPI values are in the range 0-255.
3.
Tab to the VCI field and enter value. If the VPI value is 0-39, the VCI may be 0-255, or the special character “*” indicating a VPI only translation. In this case, the VCI is passed through unchanged. If the VPI value is greater than 39, the VCI passes the VPI without translation.
4.
Tab to the Direction field and select the connection’s traffic direction. This is a toggle field, press the <SPACE> bar to move between the three possible directions: to, from, or bidirectional.
5.
Tab to the VPI field for the output interface and enter the VPI and VCI in the same manner as above.
6.
A unique connection name of up to 14 characters may be entered if desired.
7.
Tab to the Priority field and select the queuing priority for the destination interface. This is a toggle field, pressing the <SPACE> bar will move between the selections: high, medium, or low priority for each VPI/VCI. The queuing priority setting may be used to minimize cell delay variation of CBR traffic, or to prioritize traffic on “over subscribed” circuits.
As traffic enters the CMC, each cell is assigned a priority based on the setting selected for the
VPI/VCI. Any type traffic (CBR, VBR, or ABR) may be assigned any priority. Although normally CBR traffic would be assigned high priority, other types of traffic could be set to higher priority and CBR to lower, as desired. As traffic exits the CMC, it does so via the assigned priority queue for that traffic. Queuing takes place on the output port.
5-9
8.
When done, press <F1> to update the configuration. Configuration changes take place immediately upon execution.
9.
Press <F3> to add more connections or <F4> to delete.
10.
When done with all connections for this interface, highlight the <EXECUTE> button and press <ENTER> to update the configuration database and return to the Main Menu, or highlight the <UPDATE> button and press <ENTER> to update the database and remain in this screen.
NOTE:
Pressing the escape key twice (<ESC><ESC>) will exit the screen without saving any changes. The configuration will revert to the data last saved through <EXECUTE> or <UPDATE>.
5-10
CXUG
7-31-98
Station Clock Module Configuration
Configuring Interfaces
To configure a new SCM interface, follow the steps described in “Configuring Physical Interfaces” to enter the name, the interface type (Station Clock Module), the slot, and the physical interface.
Press <F2> to enter the interface configuration menu. Figure 5-12 shows the configuration menu with all fields set to the default values.
Intf name: Ref Clock Source
Slot : 12 Intf: A Intf Type: System Clock Mod
Data Rate: ________
EXECUTE
Enter the data rate in 8 KHz increm ents from 8 KHz to 50 MHz.
09:52 CFG: INTF: SCM Alarm Status Location Nam e ESC: = Prev ious
Figure 5-12. Interface Configuration Window—Station Clock Module
CXUG
7-31-98
5-11
Dual T-1 Cell Interface Module Configuration
Configuring Interfaces
To configure a new T1 interface, follow the steps described in “Configuring Physical Interfaces” to enter the name, the interface type (Dual T1 Cell), the slot, and the physical interface. Press <F2> to enter the interface configuration menu. Figure 5-13 shows the configuration menu with all fields set to the default values.
Intf Name: Walkersville Slot: 5
Framing: ESF
Coding: B8ZS
Line Build Out/Equal:
Scramble Cells: Enable
Tx Clock Out: Recovered
EXECUTE
Intf: A Intf Type: Dual T1 Cell
Press ENTER To update the config database and return to the Main Menu
09:52 CFG: Con Mgmt: Map **ALARM**
**********
ESC-ESC = Previous
Figure 5-13. Interface Configuration Window – Dual T-1 Cell
The arrow keys are used to move between the different fields. Beginning from the Framing field, the down arrow key can be used to move the cursor through each field in the following order (the space bar is used to toggle through the possible selections, which are given below in parentheses starting with the default):
•
Framing (ESF, SF)
•
Coding (B8ZS, AMI)
•
Line build out (0, -7.5, -15.0, -22.5)
•
Bit Error Rate (BER) Alarm Threshold (10-3, 10-4, 10-5, 10-6, 10-7)
•
Scramble cells (Enable, Disable)
•
Transmit clock settings (Recovered, Ref Clock, Internal, On Board)
5-12
CXUG
7-31-98
Configuring Connections
T1C connections are configured via the Connection Management menus (see “Configuring
Interface Connections”). Configuring connections to and from T1 interfaces is very similar to configuring other connections. Figure 5-14 shows the connection management window.
Name: Walkersville
Inact VPI VCI
*
Dir
<-->
<-->
Slot: 5
Interface Name
Walkersville
Germantown
Intf: A
VPI VCI
Type: Dual T1 Cell
Chan Connection Name Priority
Walker One
German two
High
Med
SCROLL UP LINE
SCROLL UP PAGE
EXECUTE UPDATE
SCROLL DOWN LINE
SCROLL DOWN PAGE
Press ENTER to update the config database and return to the Main Menu
09:52 CFG: Con Mgmt:Map **ALARM** ******************
ESC-ESC = Previous
Figure 5-14. Connection Management Window
CXUG
7-31-98
5-13
OC-3 Cell Interface Module Configuration
Configuring Interfaces
To configure a new interface, follow the steps described in “Configuring Physical Interfaces.”
Enter the name, the interface type (OC3 Cell), the slot, and the physical interface (A). Press <F2> to enter the configuration menu. Figure 5-15 shows the OC3 Cell configuration menu with all fields set to the default values.
Intf Name: Germantown Slot: 2
Tx Clock Out: Recovered
Scramble Cells:
Tx Path Trace:
Enable
Intf: A Intf Type: OC3 Cell
EXECUTE
Press EN TE R To u pdate the con fig d ataba se an d return to the Main Men u
09:52 CFG: Intf: OC3 **ALARM**
**********
ESC-ESC = Previous
Figure 5-15. Interface Configuration Window – OC3 Cell
To configure this interface, position the cursor on the Tx Clock Out field by using the up and down arrow keys. Then configure the interface for the desired framing, using the space bar to “toggle” the selection.
The arrow keys are used to move between the different fields. Beginning with the TX Clock Out field, the down arrow key can be used to move the cursor through each field in the following order
(the space bar is used to toggle through the possible selections, which are given below in parentheses starting with the default):
•
Tx Clock Out (Recovered, On Board)
•
Scramble Cells (Enable, Disable)
•
Tx Path Trace (Text string)
5-14
CXUG
7-31-98
Configuring Connections
Connections are configured via the Connection Management menus, see “Configuring Interface
Connections.” Configuring connections to and from OC3 interfaces is very similar to configuring other connections. Figure 5-16 shows the connection management mapping window.
Name: Germantown
Inact
*
VPI VCI Dir
Slot: 2
Interface Name
Emmitsburg
Walkersville
Intf: A
VPI
Type: OC3 Cell
VCI Chan Connection Name Priority
Emmit One
Walkers Two
Low
High
SCROLL UP LINE
SCROLL UP PAGE
EXECUTE UPDATE
SCROLL DOWN LINE
SCROLL DOWN PAGE
Press ENTE R to update th e config database and return to the Main Menu
11:22 CFG: Con Mgmt:Map **ALARM** ******************
ESC-ESC = Previous
Figure 5-16. Configuration Management Mapping Window – OC3 Cell
CXUG
7-31-98
5-15
Dual Synchronous Cell Interface Module
Configuration
Configuring Interfaces
To configure a new interface, follow the steps described in “Configuring Physical Interfaces.”
Enter the name, the interface type (Dual Sync Cell), the slot, and the physical interface (A or B).
Press <F2> to enter the configuration menu. Figure 5-17 shows the Synchronous Cell configuration menu with all fields set to the default values.
Intf Name: Frederick Slot: 1
Data Rate (in Kbps): 8000
Scramble Cells:
TT Clock Source:
Enable
ST
For Secured Networks
Tx Zero Blocks:
Crypto Reset:
Disable
Disable
EXECUTE
Intf: A Intf Type: Dual Sync Cell
Press EN TE R T o update the config data base and re turn to the Main Men u
09:52 CFG: Intf: Sync **ALARM**
**********
ESC-ESC = Previous
Figure 5-17. Interface Configuration Window – Dual Sync Cell
To configure this interface, position the cursor on the Data Rate field by using the up and down arrow keys. The arrow keys are used to move between the different fields. Beginning with the Data
Rate field, use the down arrow key to move the cursor through each field. The space bar is used to toggle through the possible selections (given below in parentheses, starting with the default):
•
Data Rate (Text string)
•
Scramble Cells (Enable, Disable)
•
TT Clock Source (ST, RT, Ref Clock, Internal)
•
Tx Zero Blocks (Disable, Enable)
•
Crypto Reset (Disable, Enable)
5-16
CXUG
7-31-98
Configuring Connections
Connections are configured via the Connection Management menus, see “Configuring Interface
Connections.” Configuring connections to and from synchronous cell interfaces is very similar to configuring other connections. Figure 5-18 shows the configuration management mapping window for the DSC.
Name: Frederick
Inact
*
VPI VCI
Dir
<-->
<-->
<-->
Slot: 1
Interface Name
Emmitsburg
Walkersville
Germantown
Intf: A
VPI VCI
Type: Dual Sync Cell
Chan Connection Name Priority
Emmit One
Walkers Two
German One
Low
High
High
SCROLL UP LINE
SCROLL UP PAGE
EXECUTE UPDATE
SCROLL DOWN LINE
SCROLL DOWN PAGE
Press ENTER to update the config database and return to the Main Menu
11:22 CFG: Con Mgmt:Map **ALARM** ******************
ESC-ESC = Previous
Figure 5-18. Configuration Management Mapping Window – Dual Sync Cell
CXUG
7-31-98
5-17
DS-3 Cell Interface Module Configuration
Configuring Interfaces
To configure a new interface, follow the steps described in “Configuring Physical Interfaces.”
Enter the name, the interface type (DS3), the slot, and the physical interface (A). Press <F2> to enter the configuration menu. Figure 5-19 shows the DS3 configuration menu with all fields set to the default values.
Intf Name: Urbana Slot: 6
PLCP: Enable
Line Build Out:
Scramble Cells:
Tx Clock Out:
0 To 225 Feet
Enable
Recovered
Intf: A
EXECUTE
Intf Type: DS3
Press ENTE R To upda te the config d atabase and return to the Main Menu
09:52 CFG: Intf: DS3 **ALARM**
**********
ESC-ESC = Previous
Figure 5-19. Interface Configuration Window – DS3
To configure this interface, position the cursor on the PLCP field by using the up and down arrow keys. The arrow keys are used to move between the different fields. Beginning with the PLCP
(Physical Layer Convergence Protocol) field, use the down arrow key to move the cursor through each field. The space bar is used to toggle through the possible selections (given below in parentheses, starting with the default):
•
PLCP (Enable, Disable)
•
Line Build Out (0 To 225 Feet, 225 To 450 Feet)
•
Scramble Cells (Enable, Disable)
•
Tx Clock Out (Recovered, On Board)
5-18
CXUG
7-31-98
Configuring Connections
Connections are configured via the Connection Management menus, see “Configuring Interface
Connections.” Configuring connections to and from synchronous cell interfaces is very similar to configuring other connections. Figure 5-20 shows the configuration management mapping window for the DS3.
Name: Urbana
Inact
*
VPI VCI
Dir
<-->
<-->
<-->
Slot: 6
Interface Name
Emmitsburg
Walkersville
Germantown
Intf: A
VPI VCI
Type: DS3
Chan Connection Name Priority
Emmit One
Walkers Two
German One
Low
High
High
SCROLL UP LINE
SCROLL UP PAGE
EXECUTE UPDATE
SCROLL DOWN LINE
SCROLL DOWN PAGE
Press EN TE R to update the config database and return to the Main Menu
11:22 CFG: Con Mgmt:Map **ALARM** ******************
ESC-ESC = Previous
Figure 5-20. Configuration Management Mapping Window – DS3
CXUG
7-31-98
5-19
Structured T-1 Legacy Module Configuration
Configuring STL Interfaces
To configure a new STL interface, follow the steps previously described in “Configuration
Physical Interfaces” to enter the name, the interface type (Structured T1), the slot, and the physical interface (A-H). Press F2 to enter the STL configuration menu. Figure 5-21 shows the STL configuration menu with all fields set to the default values. Here, the user is configuring interface B of the STL card in slot 14. The cursor is positioned on the Framing field (default is ESF) and the user is being prompted to select the framing mode. To configure the desired framing, the user enters the space bar to “toggle” the selection from ESF to SF.
Intf Name: Hyattsburg
Framing:
Coding:
ESF
B8ZS
Line Build Out/Equal:
BER Alarm Threshold:
Tx Clock Out:
0
10-3
On Board
Channel:
Conn:
1
1
2
1
3
1
Slot: 14
Channel:
Conn:
Channel:
Conn:
9
1
17
1
10
1
18
1
11
1
19
1
4
1
12
1
20
1
Intf: A Intf Type: Structured T1
Trunk Conditioning Data Code:
Trunk Conditioning Signaling:
Idle (UAC)
Idle (0)/Busy (1)
Idle Channel Conditioning: Voice Idle
5
1
13
1
21
1
6
1
14
1
22
1
7
1
15
1
23
1
EXECUTE
8
1
16
1
24
1
Aggregate data rate for channel grouping:
Press ENTER To update the config database and return to the Main Menu
09:52 CFG: Intf: STL **ALARM**
**********
ESC-ESC = Previous
5-20
Figure 5-21. Interface Configuration Window – Structured T-1
The arrow keys are used to move between the different fields. Beginning from the Framing field, the down arrow key can be used to move the cursor through each field in the following order (the space bar is used to toggle through the possible selections, which are given below in parentheses starting with the default):
•
Framing (ESF or SF)
•
Line coding (B8ZS or AMI)
•
Line build out (0, -7.5, -15.0, -22.5, 133_266, 266_399, 399_533, 533_655)
•
Bit Error Rate (BER) Alarm Threshold (10-3, 10-4, 10-5, 10-6, 10-7)
•
Transmit clock settings (Recovered, Ref Clock, Internal, Onboard)
•
Trunk Conditioning Data Code (Idle (UAC) or MUX-OOS)
•
Trunk Conditioning Signaling (Idle(0)/Busy(1) or Busy(1)/Idle(0))
•
Idle Channel Conditioning (Voice Idle or Data Idle)
CXUG
7-31-98
Configuring Channel Groups
The STL interface configuration menu provides a channel assignment (data entry) field for each of the 24 T1 channels. Whenever the cursor is positioned in one of the channel assignment fields, the user is prompted as follows:
Channel assignment: Valid choices: I (idle), D1-D24 (data), V1-
V24 (voice)
To configure a channel group, choose a unique channel group ID and enter it into each of the channel assignment fields of the group. Channel group IDs for data channels (64 kHz clear channel) always begin with “D” and channel group IDs for voice channels (signaling enabled) begin with “V.” Only one ID can be assigned to a particular channel. An idle channel (a channel that does not belong to a group) is configured by entering an “I” in the channel assignment field.
As shown in the Figure 5-21, all channels are initially idle when a new interface is configured.
As mentioned previously, the channels comprising a group may be contiguous or noncontiguous.
The following figure depicts two channel groups V7 and D1. Channel group V7 consists of 3 noncontiguous channels, and channel group D1 consists of 3 contiguous channels.
When the cursor is positioned in the channel assignment field of a data channel, the total bandwidth of the data channel group is displayed in units of kHz. In the example below, channel group D1 provides a total bandwidth of 192 kHz.
T1 Transmit Clock Configuration
For each configured STL interface, one of four possible T1 transmit clock sources must be selected in the interface configuration menu:
•
Recovered (the default)
•
Internal
•
Ref Clock
•
On Board
Recovered means the T1 transmit clock is derived from the received T1 signal.
Internal means the T1 transmit clock is supplied by the main CPU board.
Ref Clock means the T1 transmit clock is supplied by the currently configured reference clock source, see “Setting System Timing.” Note that an STL interface can be selected as the reference clock source for the system.
On Board means the T1 transmit clock is supplied by the STL’s on board clock source.
It is important to note that all STL interfaces that are not configured to use recovered T1 transmit clock must share the same T1 transmit clock configuration. For example, selecting Reference for one interface automatically changes the clock configuration of all of the interfaces that are not configured for recovered clock.
CXUG
7-31-98
5-21
Configuring Connections
STL connections are configured via the Connection Management menus, see “Configuring
Interface Connections.” Configuring connections to and from STL interfaces is very similar to configuring other connections. For STL connections, however, the user selects one of the channel groups instead of entering a VPI/VCI pair.
STL to Cell Bearing Interface Connections
An STL-to-Cell-Bearing connection configuration is illustrated in Figure 5-22, below. Here, a bidirectional connection is about to be enabled between a STL interface (channel group V14) and a cell-bearing interface such as an OC3 (VPI 2 and VCI 12). The channel group selection “V14/3” means that the channel group ID is V14 and is comprised of 3 channels. To select the desired channel group, the user positions the cursor in the channel group selection column (under the
“Chan” column) and presses the space bar to toggle through the configured channel groups. In this example, the name associated with the connection is “German PBX200.”
Name: Hyattsburg
Inact
Slot: 14 Intf: A Type: Structured T1
Connection Name Priority
SCROLL UP LINE
SCROLL DOWN LINE
EXECUTE UPDATE
SCROLL UP PAGE
SCROLL DOWN PAGE
F1 - Execute F3 - Add Connection F4 - Delete Connection
Figure 5-22. Connection Management Mapping Window – Structured T1
STL to STL Connections
An STL-to-STL connection configuration is shown in Figure 5-23. Here a connection is configured between channel group D1 on one STL card and channel group D5 on another. Note that both of the channel groups must contain the same number of (but not necessarily the same) channels.
CXUG
5-22
7-31-98
Name: Hyattsburg
Inact Chan
D1 /3
Dir
<-->
Slot: 14
Interface Name
Walkersville
Intf: A
VPI VCI
Type: Structured T1
Chan Connection Name Priority
D5 /3 Walker XC3 High
SCROLL UP LINE
SCROLL UP PAGE
F1 - Execute
EXECUTE
F3 - Add Connection
SCROLL DOWN LINE
UPDATE
SCROLL DOWN PAGE
F4 - Delete Connection
15:11 CFG: Con Mgmt:Map **ALARM** ******************
ESC-ESC = Previous
Figure 5-23. Connection Management Mapping Window – Structured T1
CXUG
7-31-98
5-23
Synchronous Legacy Interface Module Configuration
Configuring Interfaces
To configure a new interface, follow the steps described in “Configuring Physical Interfaces” to enter the name, the interface type, the slot, and the physical interface. Press <F2> to enter the interface configuration menu. Figure 5-24 shows the interface configuration menu with all fields set to the default values.
Intf Name: Gaithersburg Slot: 3 Intf: A
Data Rate: 1000
Adaptive Clock:
Use TT:
Invert ST:
ST and RT Clock Source:
No
No
No
Internal
EXECUTE
Intf Type: Dual Sync Leg
Press ENTER To update the config database and return to the Main Menu
16.32
CFG: Intf: Sync Leg **ALARM**
**********
ESC-ESC = Previous
Figure 5-24. Interface Configuration Window – Dual Sync Leg
The arrow keys are used to move between the different fields. Beginning at the Data Rate field, the down arrow key can be used to move the cursor through each field in the following order (the space bar is used to toggle through the possible selections, which are given below in parentheses starting with the default):
•
Data Rate (text field)
•
Adaptive Clock (No, Yes)
•
Use TT (No, Yes)
•
Invert ST (No, Yes)
•
ST and RT Clock Source (Internal, Ref Clock)
5-24
CXUG
7-31-98
Configuring Connections
Connections are configured via the Connection Management menus, see “Configuring Interface
Connections.” Configuring connections to and from synchronous legacy interfaces is very similar to configuring other connections. Figure 5-25 shows the configuration map for a Dual
Synchronous Legacy interface.
Name: Gaithersburg
Inact
VPI VCI
Dir
<-->
<--
-->
Slot: 3
Interface Name
Germantown
Urbana
Walkersville
Intf: A
VPI
2
7
--
Type: Dual Sync Leg
VCI Chan
12
14
--
--
--
V14/3
Connection Name Priority
German PBX200
Urbana One
Walker BX
High
Med
High
F1 - Execute
EXECUTE
F3 - Add Connection
UPDATE
F4 - Delete Connection
14:42 CFG: Con Mgmt:Map **ALARM** ******************
ESC-ESC = Previous
Figure 5-25. Connection Management Mapping Window – Dual Sync Leg
CXUG
7-31-98
5-25
High-Speed Synchronous Legacy Interface Module
Configuration
Configuring Interfaces
To configure a new interface, follow the steps described in “Configuring Physical Interfaces” to enter the name, the interface type, the slot, and the physical interface. Press <F2> to enter the interface configuration menu. Figure 5-26 shows the interface configuration menu with all fields set to the default values.
Intf Name: Rockville Slot: 11 Intf: A
Data Rate: 8000
Adaptive Clock:
Use TT:
Invert ST:
ST and RT Clock Source:
ST Source:
No
No
No
Internal
Normal
EXECUTE
Intf Type: High Speed Leg
Press ENTER To update the config database and return to the Main Menu
11:44 CFG: Intf: Sync Leg **ALARM**
**********
ESC-ESC = Previous
5-26
Figure 5-26. Interface Configuration Window – High-Speed Leg
The arrow keys are used to move between the different fields. Beginning at the Data Rate field, the down arrow key can be used to move the cursor through each field in the following order (the space bar is used to toggle through the possible selections, which are given below in parentheses starting with the default):
•
Data Rate (text field)
•
Adaptive Clock (No, Yes)
•
Use TT (No, Yes)
•
Invert ST (No, Yes)
•
ST and RT Clock Source (Internal, Ref Clock, External)
•
ST Source (Normal, From RT)
CXUG
7-31-98
Configuring Connections
Connections are configured via the Connection Management menus, see “Configuration Interface
Connections.” Configuring connections to and from synchronous legacy interfaces is very similar to configuring other connections. Figure 5-27 shows the configuration map for a High Speed
Synchronous Legacy interface.
Name: Rockville
Inact
VPI VCI
Dir
<-->
<--
-->
Slot: 11
Interface Name
Germantown
Urbana
Walkersville
Intf: A
VPI
2
7
--
Type: High Speed Leg
VCI Chan
12
14
--
--
--
V14/3
Connection Name Priority
German PBX200
Urbana One
Walker BX
High
Med
High
F1 - Execute
EXECUTE
F3 - Add Connection
UPDATE
F4 - Delete Connection
07:36 CFG: Con Mgmt:Map **ALARM** ******************
ESC-ESC = Previous
Figure 5-27. Connection Management Mapping Window – High-Speed Leg
CXUG
7-31-98
5-27
Chapter
6
Troubleshooting
General Troubleshooting Procedures
If the Cell Exchange system does not appear to be working properly, connect a VT100 terminal to the CPU module and enter the local management system (See Chapter 4).
If you think a cable is not working, check to ensure the cables are correctly attached and not crosswired. Check to ensure that the cable is of the correct type. In the case of an optical connection, make sure the cable is single mode or multimode, as appropriate to the application.
Power Supply Module
If the red “FAIL” LED illuminates on a Power Supply module, there is a possibility that module has failed. Here are a few quick checks to verify the status of the module.
1.
If there is only one Power Supply Module installed, a failed module will shut down the Cell
Exchange system.
a.
If the “FAIL” LED is illuminated and the Cell Exchange system is still operational, the power supply is OK, but there is a malfunction in the LED circuitry. The module should be replaced as soon as is practicable.
b.
If the Cell Exchange system is shut down, but the front panel of the power supply module is blank, AC input to the module has been lost or the fuse is blown.
2.
If there is a redundant power supply installation, the backup power supply will automatically assume the load. Check the front panel LEDs for one of the following indications: a.
If the red “FAIL” LED is illuminated, the power supply module has failed. (Since the green “POWER” LED only indicates that +5 VDC is being read at the buss, the LED may be illuminated even though the power supply has failed.) b.
If the front panel of the power supply module is blank, AC input to the module has been lost or the fuse is blown.
CPU Module
If the red “FAIL” LED illuminates on a CPU module, the module has possibly failed.
CXUG
7-31-98
6-1
1.
In a single CPU installation, a failed CPU module may not be immediately evident because it only affects cell buss timing and configuration. Over a short period of time, however, performance of the Cell Exchange system will degrade.
2.
In a dual CPU configuration, if one module fails, the other will automatically take over. This will be indicated by the illumination of the “ACTIVE” LED. If the primary CPU module has in fact failed, its “ACTIVE” LED should extinguish, and the secondary module’s “ACTIVE”
LED should illuminate.
Other Modules
Information on the front panel indicators for other Cell Exchange system modules is provided in
Chapter 3, Modules. If any module indicator is not indicating normal operation for that module, the module may be defective.
Alarms
An alarm is any out of parameter condition detected during Cell Exchange operation. If such a condition is detected, an alarm message is generated and placed in the alarm queue, and an alarm indicator is displayed on the status line. The alarm indicator provides the operator with an indication that an alarm has been generated since the last time the current list of alarms was viewed. This serves as an alarm acknowledgment mechanism for the operator.
The operator can view the current list of alarms held in the alarm queue by selecting the View menu and Alarm Log command. Upon execution, the alarm indicator being displayed is removed from the status line and the list of alarm messages is displayed in the alarm window. The current alarm is displayed in reverse video.
Alarms and their meaning are described in Table 6-1.
Alarm Message
Incorrect card configuration slot # <slot>
Table 6-1. Alarm Messages
Meaning
General
A module was detected in a slot different than the way the system is configured.
A module has been detected and successfully booted up, or has subsequently failed.
Card is alive in slot # <slot>
Card has died in slot # <slot>
Interface is up in slot # <slot>
Interface is down in slot # <slot>
Incorrect password
A configured interface/port has detected a valid signal or lost a valid signal.
The user has attempted to log in using an invalid password.
Maximum number of software versions loaded. The system has already stored the maximum number of software versions
(4) and cannot accept any more.
6-2
CXUG
7-31-98
Alarm Message
Table 6-1. Alarm Messages (Cont’d)
Meaning
Attempt to remove current operating software User has attempted to remove the currently executing version of software.
Software download succeeded or failed.
Software load successful
Software load failed
Attempt to configure connection for multicast interface
User has attempted to configure connection mappings for a
Station Clock Module (SCM) or a multicast interface (not implemented yet). No connection mappings are allowed for
SCM Modules.
Power Supply Module has been detected as available or failed.
Power supply is up: <A/B>
Power supply is down: <A/B>
LAN Emulation Client is active
LAN Emulation Client is down
Screen validation failed! <additional failure reason>
Check destination interface (destination field is bogus)
Source VCI exceeds max (connection vci was
>65535)
Destination VCI exceeds max (connection vci was
>65535)
Source VPI exceeds max (connection vpi was
>255)
Destination VPI exceeds max (connection vpi was
>255)
Invalid STL source channel group
The LAN Emulation Client has successfully connected to a
LAN Emulation Server, or has subsequently been disconnected from the server.
User has entered invalid configuration information. Where appropriate, the cursor is placed on the invalid item and the
"failure reason" is given. Some of the additional failure reasons are: Connection Mapping Validation
VPI only must be consistent (one half of a connection was specified as VPI only, but the other half was not)
Too many connections for interface (legacy interfaces are only allowed one connection in each direction)
Invalid STL destination channel group
Invalid SEL source channel group
Invalid SEL destination channel group
Duplicate source VPI/VCI pair
Duplicate source channel group
VPI/VCI pair used by SVC
Destination VPI/VCI pair in use
A connection to an STL interface did not specify a valid channel group id for that interface.
A connection to an STL interface did not specify a valid channel group id for that interface.
A connection to an STL interface did not specify a valid channel group id for that interface.
A connection to an STL interface did not specify a valid channel group id for that interface.
A source vpi/vci pair is used more than once for an interface
A source channel group of an STL, SEL, or HRIM interface is used more than once.
The source vpi/vci pair for the interface is already being used by the system's LAN Emulation Client.
The destination vpi/vci pair is used more than once for an interface.
CXUG
7-31-98
6-3
Alarm Message
Table 6-1. Alarm Messages (Cont’d)
Meaning
Destination channel group in use
Destination VPI/VCI used by SNMP SVC
Destination VPI/VCI used by SNMP PVC
Cannot remove current system timer
Can't remove/deactivate SNMP connections!
Can't change card type! Do REMOVE+ADD
The destination channel group of an STL, SEL, or HRIM interface is used more than once.
The destination vpi/vci pair for the interface is already being used by the system's LAN Emulation Client.
The destination vpi/vci pair for the interface is already being used for an SNMP PVC connection.
Logical Interfaces
User is trying to delete a logical interface that is being used as the source of system timing. User must first change the source of system timing before deleting this interface.
User is trying to delete a logical interface that is being used for
SNMP connections. User must first change the interface used for SNMP before deleting this interface.
To change the card type of an existing interface, the user should delete the old interface (F4) and add the new interface
(F3).
User did not fill in the interface name field for a logical interface Empty interface name slot# <slot >
Duplicate interface name slot# <slot>
Duplicate definition slot# <slot>
Exceeded max interfaces slot# <slot>
Empty channel Id field
Duplicate channel Id
Channel bandwidth over limit
Duplicate interface names exist.
User has entered more than one logical interface for the same slot. For example, user may have tried to define one module type for port A and a different module type for port B.
User has defined more logical interfaces than are allowed for the type of interface module. For example, three logical interface for a Dual Sync Cell Module.
Interface Physical Configuration
Can't modify group in use, chan# <channel>
No channel ID field filled in for HRIM configuration.
Duplicate channel id field for HRIM configuration.
User has defined aggregate bandwidth that exceeds the
25Mbps limit for HRIM configuration.
For STL or SEL configuration.
READ COMMUNITY string < 5 chars
WRITE COMMUNITY string < 5 chars chars
TRAP COMMUNITY string < 5 chars chars
Connection <PVC connection #>: VPI/VCI pair in use
Connection <PVC connection #>: invalid VPI/VCI choice
Connection <PVC connection #>: VPI/VCI used by SVC
Invalid CPU IP Add
SNMP
Community string must be at least five characters.
Community string must be at least five characters.
Community string must be at least five characters.
VPI/VCI pair is already in use for the selected interface.
Invalid vpi/vci numbers were entered (e.g. 0-0).
The pvc vpi/vci is already being used for a LAN Emulation
Client connection.
Invalid IP address entered.
6-4
CXUG
7-31-98
Alarm Message
Table 6-1. Alarm Messages (Cont’d)
Meaning
Invalid CPU Subnet Mask
Invalid Gateway IP Addr
Invalid IP subnet mask entered.
Invalid IP address entered.
No valid Trap IP Addr
Management validation failed: <additional failure reason>
Invalid IP address entered.
Configuration request from SNMP management failed. Failure reasons are similar to those for "Screen validation failed."
Craft Interface Display Alarms
Power Supply is up
Power Supply is down
Power Supply Module has been detected as available or failed.
A module has been detected and successfully booted up, or has subsequently failed.
Card Alive
Card Died
Interface Up
Interface Down
Incorrect Card Configuration
Management Validation Failed
LAN Emulation Client Active
LAN Emulation Client Down
A configured interface/port has detected a valid signal or lost a valid signal.
A module has been configured incorrectly.
A typical alarm screen is shown in Figure 6-1.
CXUG
7-31-98
Descri ption
Power Supply is up: A
Card is alive in slot # 5
Card is alive in slot # 11
Card has died in slot #3
Software load successful
Time Stamp
05/22/98
05/22/98
05/22/98
05/22/98
05/22/98
10:15
10:15
10:15
11:32
13:40
SCROLL UP LINE
SCROLL UP PAGE
DELETE ALL ACTIVE ALARMS ALL ALARMS
SCROLL DOWN LINE
SCROLL DOWN PAGE
Press ENTER to scr oll records up one line
10:45
CFG: SNMP:Config
**ALARM**
**************
ESC-ESC = Previous
Figure 6-1. Alarm Log Window
The operator can delete all alarms from the alarm log:
•
Using the <TAB> or <ARROW> key, move to the DELETE ALL button.
•
Press the <ENTER> key.
Clearing alarms is at the operator’s discretion, but it is recommended that alarms be cleared as soon as the condition is resolved or properly isolated. The alarm log will only store up to 54 alarms
6-5
(3 pages). If the alarm log is full and a new alarm is detected, the system will automatically delete the oldest alarm and record the newest.
User-initiated Tests
The user can diagnose a range of system components, from a single interface module to network connectivity. The operator can control each data port’s role in the diagnostic procedure. Each port has the capability to loop the data traffic back in either direction: back to the external connecting equipment; or back into the Cell Exchange system. The loopbacks are unique to the port used. The configuration screen for conducting loopback testing is shown in Figure 6-2. The loopback data flow is shown in Figure 6-3.
Associated Logical Interface:
Loopback Status:
----------------
Enable
EXECUTE
Select interface for configuring loopback state
18:46 DIAG: Loopback
**ALARM**
**************
ESC-ESC = Previous
Figure 6-2. Loopback Window from Diagnostics Menu
6-6
CXUG
7-31-98
Equipment
Interface Card
Network
Figure 6-3. Loopback Data Flow
CXUG
7-31-98
6-7
Chapter
7
Replacement Procedures
This section provides information for repair and replacement of failed modules on the Cell
Exchange system. The basic maintenance concept for the Cell Exchange system is limited to onequipment repair. Since the Cell Exchange system is modular in design, it lends itself readily to logical and straightforward maintenance procedures consisting of the removal and replacement of components.
Electrostatic Discharge (ESD) Anti-Static Procedure
When performing any maintenance action on the Cell Exchange system, observe the following procedures:
1.
Ensure that the Cell Exchange system is properly grounded.
2.
Connect an ESD wrist strap to the same ground as the Cell Exchange system.
3.
Put the wrist strap on before handling any module or the chassis of the Cell Exchange system.
4.
Use protective ESD bags to handle, store, or ship Cell exchange system components.
5.
If the maintenance or replacement action requires removing a module, do the following:
•
Remove the replacement module from its protective ESD bag and lay it on the bag.
•
Remove the defective module and lay it on another ESD bag or on the same bag.
6.
When maintenance or replacement is complete, remove the wrist strap and disconnect it from ground.
Removing and Replacing Chassis
To remove the Cell Exchange system from the rack:
1.
Turn the power switch(es) to the OFF (0) position.
2.
Unplug the power cord(s) from the power source receptacle and rear panel connector.
3.
Remove the grounding strap from the grounding lug on the rear panel (backplane).
4.
Remove the screws attaching the chassis to the equipment rack.
5.
Slide the chassis out of the rack.
CXUG
7-31-98
7-1
To replace the chassis:
1.
Slide the new chassis into the rack.
2.
Replace the screws attaching the chassis to the equipment rack.
3.
Attach the grounding strap to the grounding lug on the rear panel.
4.
Plug the power cord(s) into the rear panel connector and power source receptacle.
5.
Turn the power switch(es) to the ON (1) position.
PRECAUTION: Secure the AC power cable to the AC connector on the rear panel before connecting the cable to the AC power source. Failure to comply with this procedure may result in electrical shock.
Removing and Replacing Modules
All modules in the Cell Exchange system may be removed and replaced without removing electrical power from the chassis (hot swap). Figure 7-1 represents the removal of a Power Supply Module, but all Cell Exchange system modules are similar.
POW
ER
FAI L
EL1 5
00
CE
LL M
TRA
UX
TOR
CON
CEN
S
I
SIM
ULA
T IO
OR
ATO
N
S
RI E
TED
L AB
I NC
ORP
ORA
OC3
OC3
DSC
DSC
OP N
L
OPN
L
A
A
DSL
OC3
OC3
CPU
CPU
OPN
L
OPN
L
OP NL
OP N
L
F A IL
AC
TV
ACC
S
NL
OP
FAI L
V
ACT
AC
CS
Rx
Rx
A
Tx
Tx
OPN
L
MOD
EL1
500
POW
ER
FAI L
Rx
Tx
Rx
Tx
B
Rx S yn
Ce S yn
Rx S y n
Ce
Syn
B
B
Rx S yn
ATM
CE
LL M
UX
Ce
S yn
CON
CE N
TRA
TOR
Rx S yn
Ce S yn
DSC
DSL
DSL
OPN L
OP
NL
OP
NL
OC3
OC3
DSC
OPN L
OC3
NL
OP
OP
NL
A
Rx
Rx
Tx
Rx
A
Tx
A
Tx
A yn
Rx S
Syn
Ce
B
Rx S yn
Ce
Syn yn
Ce S
B
B
B
OC3
OC3
CPU
CPU
DSC
DSL
DSL
OC3
OC3
DSC
OC3
DSC
DSL
SIM
UL A
TI ON
LAB
O RA
INC
O RP
IES
T OR
O RA
TED
OC3
OC3
DSC
Figure 7-1. Removal of a Cell Exchange System Module (Power Supply)
7-2
CXUG
7-31-98
Model CX-1500 Power Supply Module
PRECAUTION: Observe electrostatic discharge (ESD) precautions when handling any Cell Exchange system module. If ESD precautions are not taken, sensitive components may be permanently damaged.
To remove the Power Supply Module:
1.
Turn the power switch to the OFF (0) position.
2.
Unplug the power cord from both the power source receptacle and the rear panel connector.
3.
Loosen the four captive screws securing the module to the chassis.
4.
Remove the module by pulling it straight out. Be careful not to twist or bend the module.
To replace the Power Supply Module:
1.
Slide the replacement module straight back into the chassis, aligning the power connector and
DIN connector with the backplane slot. Make sure the connector is fully seated.
2.
Tighten the four screws in the module front panel securely.
3.
Connect one end of the power cord to the rear panel connector and the other end to the power source.
4.
Turn the power switch to the ON (1) position.
NOTE:
Never force the screws when starting them. If they become difficult to turn, back them off and start over.
CPU Module
PRECAUTION: Observe electrostatic discharge (ESD) precautions when handling any Cell Exchange system module. If ESD precautions are not taken, sensitive components may be permanently damaged.
PRECAUTION: The CPU Module must be installed in slot 8 of Model CX-
1500 and in any slot except slot 1 of Model CX-1540.
To remove the CPU Module:
1.
Loosen the two captive screws securing the module to the chassis.
2.
Remove the module by pulling it straight out. Be careful not to twist or bend the module.
CXUG
7-31-98
7-3
To replace the CPU Module:
1.
Slide the replacement module straight back into the chassis, aligning the DIN connector with the backplane slot. Make sure the connector is fully seated.
2.
Tighten the two screws in the module front panel securely.
NOTE:
Never force the screws when starting them. If they become difficult to turn, back them off and start over.
Other Modules
PRECAUTION: Observe electrostatic discharge (ESD) precautions when handling any Cell Exchange system module. If ESD precautions are not taken, sensitive components may be permanently damaged.
To remove the modules:
1.
Remove any cables from the connectors on the front panel.
Observe the following precautions when removing the OC-3 Interface Module: a.
Remove the fiber optic cable connectors individually and cap with protective plastic caps.
b.
Stow any removed fiber optic cables in a protected spot where they will not be pulled or bent tighter than a 6-inch radius.
PRECAUTION: Working with fiber optic cables can be hazardous to personnel and, if mishandled, can cause permanent damage to the cables.
WARNING: THE FIBER-OPTIC CONNECTORS MAY EMIT LASER
LIGHT THAT CAN INJURE YOUR EYES. NEVER LOOK
INTO AN OPTICAL FIBER CONNECTOR OR CABLE.
PRECAUTION: Fiber optic cables require special handling. They must not be bent to a radius of less than six inches. When exposed, optical fibers (contained within the fiber-optic cable) are extremely brittle and fragments from the fiber can easily penetrate the skin or eyes. Wear protective goggles and clothing when working with the optical fibers.
2.
Loosen the two captive screws securing the module to the chassis.
3.
Remove the module by pulling it straight out. Be careful not to twist or bend the module.
To replace the module:
7-4
CXUG
7-31-98
1.
Slide the replacement module straight back into the chassis, aligning the DIN connector with the backplane slot. Make sure the connector is fully seated.
2.
Tighten the two screws in the module front panel securely.
NOTE:
Never force the screws when starting them. If they become difficult to turn, back them off and start over.
3.
Reattach any cables to the front panel connectors.
WARNING: SOME FIBER-OPTIC CONNECTORS MAY EMIT LASER
LIGHT THAT CAN INJURE YOUR EYES. NEVER LOOK
INTO AN OPTICAL FIBER CONNECTOR OR CABLE.
PRECAUTION: The fiber optic cables require special handling. They must not be bent to a radius of less than six inches.
Fuse Replacement
The Cell Exchange system is protected by a fuse in each AC connector module located on the rear panel of the chassis. To replace a fuse:
1.
Turn the power switch of the affected module to the OFF (0) position.
2.
Unplug the affected power cord from the source receptacle.
3.
Unplug the other end of the power cord from the connector module on the rear of the chassis.
4.
Pry open the protective cover over the fuse receptacle on the connector, exposing the fuse. (See
Figure 7-2.)
5.
Remove fuse with fuse puller and replace with a 250V, 3 Amp, normal-blo fuse.
PRECAUTION: Ensure that the rating on the replacement fuse is the same as that of the old fuse. Failure to do so could result in electrical shock hazard and equipment damage.
6.
Snap protective cover back over fuse well.
7.
Reconnect power cord.
8.
Turn the power switch to the ON (1) position.
PRECAUTION: Secure the AC power cable to the AC connector on the rear panel before connecting the cable to the AC power source. Failure to comply with this procedure may result in receiving an electrical shock.
CXUG
7-31-98
7-5
POWER SUPPLY A
!
CAUTION: For continued protection from risk of fire, replace with only same type and rating of fuse.
O
I
115 VAC 60 Hz Use 3.0 Amp 250 V Fuse
POWER SUPPLY B
O
I
Figure 7-2. Rear Panel AC Connector with Fuse Well Exposed
7-6
CXUG
7-31-98
Appendix
A
Asynchronous Transfer Mode
Asynchronous Transfer Mode (ATM) technology was developed for the high-speed transfer of voice, video, and data through private networks and across public networks. ATM technology provides a way of linking a wide range of devices (from telephones to computers) using one seamless network. It removes the distinction between local area and wide area networks, integrating them into one network. ATM can integrate all traffic types, eliminating parallel networks supporting different applications (like voice and data) and multiple links to the same location. It supports both bursty data and delay sensitive traffic.
ATM is a cell-switching and multiplexing technology that combines the benefits of circuit switching (constant transmission delay and guaranteed capacity) with those of packet switching
(flexibility and efficiency for intermittent traffic). ATM uses an unchannelized bandwidth approach for traffic transport. Like X.25 and Frame Relay, ATM defines the interface between the user equipment (such as workstations and routers) and the network. This interface is referred to as the
User-Network Interface (UNI).
The asynchronous in ATM refers to the way in which ATM achieves its unchannelized bandwidth allocation. ATM differs from synchronous transfer mode methods, where time-division multiplexing (TDM) techniques are employed to pre-assign users to time slots. ATM time slots are made available on demand, with information identifying the source of the transmission contained in the header of each ATM cell. Relative to ATM, TDM is inefficient because a time slot is wasted when a station has nothing to transmit. Also, when a station has more information to transmit that can fit into its allotted time slots, only part of the information can be sent at that time even though other time slots may be empty. With ATM, a station can send cells whenever necessary.
ATM networks allow for strict quality-of-service guarantees because network resources are allocated on a per connection basis. Cell sequence integrity is maintained because routing decisions are made only at connection establishment time.
ATM Networks
ATM networks are connection-oriented, where virtual connections are established between endsystems, and cells are switched according to connection identifiers. The network architecture uses unchannelized network transports. Since there are no physical channels to distinguish the traffic in an ATM network, logical connections are established. Instead of voice and video channels, ATM has voice and video connections. These logical connections are established and maintained by means of a two-part identifier structure: the virtual path and the virtual channel.
A virtual path (VP) is a concept used to describe the transport of cells belonging to a set of virtual channels. Each VP is assigned a unique identification value, called the virtual path identifier (VPI).
CXUG
7-31-98
A-1
A virtual channel (VC) is a concept used to describe the transport of ATM cells associated by a unique identification value, called the virtual channel identifier (VCI). A VP is a logical grouping of VCs that allows an ATM switch to perform operations on groups of virtual circuits.
ATM switches use the VPI and VCI fields located in the cell header to identify the next network segment that a cell needs to transit on its way to its final destination. A virtual channel is equivalent to a virtual circuit; both terms describe a logical connection between the two ends of a communications connection. As a result, ATM offers a private switched connection for each user.
The concept of virtual circuit simplifies routing once a path is established, and allows components within the network to simply distinguish among different traffic flows for purposes of admission, congestion control, and security. Multiplexing and switching in ATM are always done on VPs first and then on VCs.
ATM Cell
ATM uses very large-scale integration (VLSI) technology to segment data at high speeds into units called cells. Cells transit ATM networks by passing through switches, which analyze information in the header to switch the cell to the appropriate output port. The cell moves from switch to switch as it works its way to its destination.
ATM technology is based entirely on cell structure. The ATM cell is a 53-byte fixed length cell consisting of a 48-byte information field (cell payload) to carry user or network information, and a
5-byte header that contains information used to route the cell to its destination (Figure A-1). The header and cell payload remain constant at both the user-network interface (UNI) and networknetwork interface (NNI). Cells are assigned on demand, depending upon the source activity and available resources. Unlike earlier LAN or WAN techniques, ATM cells can be sent over a wider variety of media types (e.g., copper wire or fiber optic cable) and a wider range of transmission speeds (e.g., up to 622 Mbps).
A-2
CXUG
7-31-98
8 7
GFC
6 5
BIT
4 3
VPI
2 1
1
VPI VCI
2
VCI
VCI
PTI CLP
HEC
GFC: Generic Flow Control
VCI: Virtual Channel Identifier
CLP: Cell Loss Priority
Cell Payload
(48 octets)
VPI: Virtual Path Identifier
PTI: Payload Type Indicator
HEC: Header Error Check
6
•
•
•
53
3
4
O
C
T
E
T
5
Figure A-1. ATM Cell Structure
The main function of an ATM switch is to receive cells on one port and switch those cells to the proper output port based on the VPI and VCI values of the cell. This switching is dictated by a switching table that maps input ports to output ports based on the values of the VPI and VCI fields.
ATM Reference Model
The ATM transport network common to all services is structured into an ATM layer and a physical layer. Figure A-2 is a reference model that illustrates the organization of ATM functionality and the interrelationships between the layers of functionality.
In the ATM reference model, the ATM layer and the ATM adaptation layers are roughly analogous parts of the data link layer of the Open System Interconnection (OSI) reference model, and the ATM physical layer is analogous to the physical layer of the OSI reference model. The control plane is responsible for generating and managing signaling requests. The user plane is responsible for managing the transfer of data. Above the ATM adaptation layer are higher-layer protocols representing traditional transports and applications.
CXUG
7-31-98
A-3
Management Plane
Control Plane User Plane
Higher Layers Higher Layers
ATM Adaptation Layer
ATM Layer
Physical Layer y e r
L a n t g e m e n a
M a n a g e
M a n t m e a n e
P l
Figure A-2. ATM Reference Model
Physical Layer
The ATM physical layer controls the transmission and receipt of bits on the physical medium. It also keeps track of ATM cell boundaries and packages cells into the appropriate type of frame for the physical medium being used. ATM can use any physical medium capable of carrying ATM cells. Some existing standards that can carry ATM cells are SONET (Synchronous Optical
Network)/SDH, DS-3/E3, 100-Mbps local fiber (Fiber Distributed Data Interface [FDDI] physical layer), and 155-Mbps local fiber (Fiber Channel physical layer).
ATM Layer
The ATM layer is fully independent of the physical medium (physical layer) used to transport the
ATM cells and applications it supports above the ATM layer. This allows a wide range of upperlayer services to be supported by a single transfer mode over multiple physical media. The result is not only an integrated data transfer but also the ability to support novel integrated applications.
The ATM layer is responsible for establishing connections and passing cells through the ATM network. To do this, it uses the information contained in the header of each ATM cell. The ATM layer maps network layer addresses to ATM addresses.
The primary function of the cell header is to identify cells that belong to a virtual channel (VC).
The ATM layer also supports a virtual path (VP), identified by the virtual path identifier (VPI).
The information field of a cell is transported transparently by the ATM layer. In addition, the
A-4
CXUG
7-31-98
ATM layer preserves the cell sequence integrity on a virtual channel connection. The ATM layer provides single bit error correction on the ATM header.
ATM Adaptation Layer
The ATM adaptation layer (AAL) translates between the larger service data units (SDUs) (for example, video streams and data packets) of upper-layer processes and ATM cells. Specifically, the ATM adaptation layer (AAL) receives packets from upper-level protocols (such as AppleTalk,
Internet Protocols [IP], and NetWare) and breaks them into the 48-byte segments that form the payload field of an ATM cell.
The primary function of the ATM adaptation layer (AAL) is to segment user data into ATM cells and to reassemble the ATM cells into user data at the destination end system. This layer can provide end-to-end error control, buffering, flow control, and multiplexing based on the applications requirements. The AAL is divided into 4 classes of service, as shown in Figure A-3.
Timing Relationship Between
Source and Destination
Bit Rate
Connection Mode
Class A
Required
Constant
Class B
Connection Oriented
Class C
Not Required
Class D
Variable
Connectionless
Figure A-3. Service Classification for AAL
Some examples of different service classifications include:
Class A: Circuit Emulation, Video
Class B: Variable Bit Rate Video and Audio
Class C: Connection-oriented Data Transfer
Class D: Connectionless Data Transfer
Quality of Service
When an ATM end station connects to the ATM network, it is essentially making a contract with the network based on quality of service (QoS) parameters. This contract specifies an envelope that describes the intended traffic flow. This envelope specifies values for peak bandwidth, average sustained bandwidth, and burst size.
CXUG
7-31-98
A-5
It is the responsibility of the ATM device to adhere to the contract by means of traffic shaping.
Traffic shaping is the use of queues to constrain data bursts, limit peak data rate, and smooth jitter so that the traffic will fit within the promised envelope.
ATM switches have the option of using traffic policing to enforce the contract. The switch can measure the actual traffic flow and compare it against the agreed upon traffic envelope. If it finds that traffic is outside of the agreed upon parameters, the switch can set the Cell Loss Priority
(CLP) bit of the offending cells. Setting the CLP bit makes the cell eligible for discard, which means that the switch, or any other switch handling the cell, is allowed to drop the cell during periods of congestion.
Congestion control is a primary concern of ATM designers. For example, dropping just one cell that is part of a FDDI frame can result in the retransmission of 93 cells. Retransmission can lead to an exponential increase in congestion. As ATM switches drop individual cells from different packets, more packets are retransmitted, causing even more cells to be dropped.
ATM References
There are a number of commercial books available that will provide a good primer or additional information regarding ATM networks. Two are cited here.
Black, Uyless; ATM: Foundation for Broadband Networks; Prentice-Hall; 1995
Goralski, Walter J.; Introduction to ATM Networking; McGraw-Hill, Inc.; 1995
A-6
CXUG
7-31-98
Appendix
B
Cable Diagrams
This appendix contains wiring diagrams for CX-1500/CX-1540 cables. Table B-1 defines which cables are applicable to each module and Table B-2 provides an index of the available cables listed be part number.
613004-X
613005-X
613006-X
613003-X
613007-X
610127-X
610126-X
61362
61359
61385
120405-X
FOXN0004
FOXN0005
Part Number
650252-X
Table B-1. Cable Applicability Matrix
Module Types
Description CPU SCM T1C OC3 DSC DS3 STL DSL HSL
DB-9 (F) to DB-9 (F) X
650074-X
650075-X
610133-X
613008-X
613009-X
DB-9 (F) to DB-25 (F)
DB-9 (F) to DB-25 (M)
DB-9 (F) to DB-25 (M)
HDB-26 (M) to DB-25 (M),
RS-530
HDB-26 (M) to DB-25 (F), RS-
530
HDB-26 (M) to DB-25 (M)
HDB-26 (M) to DB-37 (M)
HDB-26 (M) to DB-37 (F)
HDB-26 (M) to DB-34 (M)
HDB-26 (M) to DB-34 (F)
RJ-45 to RJ-45 (Straight)
RJ-45 to RJ-45 (Crossover)
RJ-45 to DB-15 (F)
DB-15 (M) to DB-15 (M)
DB-15 (M) to DB-15 (M)
BNC (M) to BNC (M)
SC (M) to SC (M)
SC (M) to ST (M)
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
CXUG
7-31-98
B-1
Part No.
650252-X
Cable Model
CPU-VT100/9F
650074-X CPU-VT100/25F
650075-X CPU-VT100/25M
610133-X ST/NCP-MDM
613008-X DSC-530M
613009-X DSC-530F
613004-X DSL/HSL-ILC
613005-X DSL/HSL/SCM-449M
613006-X DSL/HSL/SCM-449F
613003-X DSL/HSL/SCM-V35M
613007-X DSL/HSL/SCM-V35F
610127-X ST/MOD-MOD
610126-X ST/MOD-XFR
61362 BADP
61359 BIM-PBX-F
Table B-2. Cable Index
Connector Figure
9 Pin DB (F) –9
Pin DB (F)
B-1A
B-1B 9 Pin DB (F) – 25
Pin DB (F)
9 Pin DB (F) – 25
Pin DB (M)
9 Pin DB (F) – 25
Pin DB (M)
26 Pin HDB (M) –
25 Pin DB (M)
B-1C
B-2
B-3
26 Pin HDB (M) –
25 Pin DB (F)
26 Pin HDB (M) –
25 Pin DB (M)
26 Pin HDB (M) –
37 Pin DB (M)
B-3
B-4
B-5
B-5
Description
CPU craft interface to VT100 terminal
CPU craft interface to VT100 terminal
CPU craft interface to VT100 terminal
CPU craft interface to VT100 terminal via modem
DSC Module (DTE) to RS-530 ATM facility
DSL/HSL Modules (DCE) and SCM
Module to V.11 (RS-530)
DSC Module (DTE) to RS-530 ATM facility
DSL/HSL Modules (DCE) and SCM
Module to V.11 (RS-530)
DSL/HSL Modules to LINK/2+ or entréeLINK+ ILC Module
DSL/HSL Modules to LINK/100+ DLI.0
Module and RS-449
SCM Module to RS-449
DSL/HSL/SCM Modules to RS-449 26 Pin HDB (M) –
37 Pin DB (F)
26 Pin HDB (M) –
34 Pin DB (M)
26 Pin HDB (M) –
34 Pin DB (F)
8 Pin Mod – 8 Pin
Mod
8 Pin Mod – 8 Pin
Mod
8 Pin Mod – 15
Pin DB (F)
15 Pin DB (M) –
15 Pin DB (M)
B-6
B-6
B-7
B-8
B-9
B-10
DSL/HSL/SCM Modules to V.35
Winchester
DSL/HSL/SCM Modules to V.35
Winchester
STL Module to LINK/2+ BFM/BIM.1,
LINK/100+ DLI.1 Module, entréeLINK+
CSU Module, or ST Dpanel-4/PRI
(T1M/E1M)
T1C Module to CSU/Smart Jack (straight)
T1C Module to CSU/Smart Jack
(crossover)
STL Module to ST Dpanel-4/DSX-1 via
BIM/PBX cable (61359)
T1C Module to CSU/Smart Jack (straight) via DSX-1/CSU cable (61385)
STL Module (via BADP cable) to ST
Dpanel-4/DSX-1
B-2
CXUG
7-31-98
Part No.
61385
Cable Model
DSX-1/CSU
120405-X TX3-DS3
FOXN0004 OC3-SM
FOXN0005 OC3-MM
Table B-2. Cable Index (Cont’d)
Connector
15 Pin DB (M) –
15 Pin DB (M)
Figure
B-11
Description
T1C Module (via BADP cable) to
CSU/Smart Jack
Male/Male BNC B-12
SC SM (M) – ST
SM (M)
SC MM (M) – SC
MM (M)
B-13
B-14
DS-3 Module to DS3 (45Mbps) facility
(ANSI T1.107)
OC-3 Module to 155 Mbps single mode service (SONET)
OC-3 Module to 155 Mbps multimode service (SONET)
CXUG
7-31-98
B-3
B-4
CPU
N/C
RD
SD
N/C
SIG GND
N/C
RTS
CTS
N/C
3
4
5
1
2
8
9
6
7
TERMINAL
2
6
5
1
3
7
9
4
8
N/C
CTS
RTS
N/C
N/C
SD
RD
N/C
SIG GND
9-PIN
FEMALE
9-PIN
FEMALE
A. 9-PIN FEMALE TO 9-PIN FEMALE (650252-X)
CPU TERMINAL
SIG GND
N/C
RTS
CTS
N/C
N/C
RD
SD
N/C
7
8
9
5
6
3
4
1
2
6
7
2
3
20
4
5
1
SD
RD
DSR
SIG GND
DTR
RTS
CTS
FRAME GND
9-PIN
FEMALE
25-PIN
FEMALE
B. 9-PIN FEMALE TO 25-PIN FEMALE (650074-X)
CPU TERMINAL
SIG GND
N/C
RTS
CTS
N/C
N/C
RD
SD
N/C
7
8
9
5
6
3
4
1
2
20
4
5
1
6
7
2
3
SD
RD
DSR
SIG GND
DTR
RTS
CTS
FRAME GND
9-PIN
FEMALE
25-PIN
MALE
C. 9-PIN FEMALE TO 25-PIN MALE (650075-X)
Figure B-1. CPU Craft Interface to VT100 Terminal
CXUG
7-31-98
CPU
N/C
RD
SD
N/C
SIG GND
N/C
RTS
CTS
N/C
7
8
5
6
9
3
4
1
2
9-PIN
FEMALE
MODEM
6
4
20
7
5
22
8
3
2
DCD
RD
SD
DTR
SIG GND
DSR
RTS
CTS
RI
25-PIN
MALE
Figure B-2. CPU Craft Interface to Modem (610133-X)
CXUG
7-31-98
B-5
B-6
SCM, DSL,
QSL, HSL
14
6
16
8
25
4
22
5
12
15
23
17
11
3
1
2
19
9
24
7
26
18
13
21
20
26-PIN
MALE
RTB
RSA
RSB
CSA
CSB
DMA
DMB
RRA
FG
SDA
SDB
RDA
RDB
STA
STB
RTA
RRB
TTA
TTB
TRA
TRB
LL
RL
SG
KG RST
RS-530
13
6
22
8
19
5
9
4
16
15
12
17
14
3
1
2
23
18
21
7
25
10
24
11
20
25-PIN
MALE
RTB
RSA
RSB
CSA
CSB
DMA
DMB
RRA
FRM GND
SDA
SDB
RDA
RDB
STA
STB
RTA
RRB
TTA
TTB
TRA
TRB
LL
RL
SIG GND
KG RST
Figure B-3. DSC/DSL/HSL/SCM Modules to RS-530 (V.11) (613008-X) (Sheet 1 of 2)
CXUG
7-31-98
CXUG
7-31-98
SCM, DSL,
QSL, HSL
14
6
16
8
25
4
22
5
12
15
23
17
11
3
1
2
19
9
24
7
26
18
13
21
20
26-PIN
MALE
DMA
DMB
RRA
RRB
TTA
TTB
TRA
TRB
LL
RL
SG
KG RST
FG
SDA
SDB
RDA
RDB
STA
STB
RTA
RTB
RSA
RSB
CSA
CSB
RS-530
25-PIN
FEMALE
TTA
TTB
TRA
TRB
LL
RL
SIG GND
KG RST
RSA
RSB
CSA
CSB
DMA
DMB
RRA
RRB
FRM GND
SDA
SDB
RDA
RDB
STA
STB
RTA
RTB
13
6
22
8
19
5
9
4
16
15
12
17
14
3
1
2
23
18
21
7
25
10
24
11
20
Figure B-3. DSC/DSL/HSL/SCM Modules to RS-530 (V.11) (613009-X) (Sheet 2)
B-7
B-8
DSL,
QSL, HSL
STB
LL
RL
RTA
RTB
TM
TTA
TTB
SDA
SDB
RDA
RDB
DMA
DMB
SIG GND
STA
TRA
RRA
TRB
RRB
25
10
13
21
23
9
24
17
20
8
19
18
6
16
7
15
2
11
3
12
26-PIN
MALE
LINK/2+ OR entréeLINK+ ILC
STA
STB
LL
RL
RTA
RTB
TM
TTA
TTB
RR
DTR
SHIELD
SDA
SDB
RDA
RDB
DMA
DMB
SIG GND
17
12
18
24
15
19
16
25
14
8
20
23
6
5
7
13
3
1
2
25-PIN
MALE
Figure B-4. DSL/HSL Modules (DCE) to LINK/2+ or entréeLINK+ ILC Module (613004-X)
CXUG
7-31-98
CXUG
7-31-98
DSL, QSL,
HSL, SCM
25
10
13
21
23
9
24
17
6
16
7
15
2
11
3
12
4
22
5
14
8
18
20
19
26-PIN
MALE
RRA
RRB
TRA
TRB
RSA
RSB
CSA
CSB
STB
LL
RL
RTA
RTB
TM
TTA
TTB
SDA
SDB
RDA
RDB
DMA
DMB
SIG GND
STA
RS-449
8
26
18
17
35
5
23
10
14
24
11
29
19
22
6
1
4
7
25
9
27
13
31
12
30
37-PIN
MALE
SHIELD
SDA
SDB
RDA
RDB
RTB
TM
TTA
TTB
RRA
RRB
TRA
TRB
DMA
DMB
SIG GND
STA
STB
LL
RL
RTA
RSA
RSB
CSA
CSB
Figure B-5. DSL/HSL/SCM Modules to RS-449 (613005-X) (Sheet 1 of 2)
B-9
B-10
DSL, QSL,
HSL, SCM
25
10
13
21
23
9
24
17
6
16
7
15
2
11
3
12
4
22
5
14
8
18
20
19
26-PIN
MALE
RRA
RRB
TRA
TRB
RSA
RSB
CSA
CSB
STB
LL
RL
RTA
RTB
TM
TTA
TTB
SDA
SDB
RDA
RDB
DMA
DMB
SIG GND
STA
RS-449
8
26
18
17
35
5
23
10
14
24
11
29
19
22
6
1
4
7
25
9
27
13
31
12
30
37-PIN
FEMALE
SHIELD
SDA
SDB
RDA
RDB
RTB
TM
TTA
TTB
RRA
RRB
TRA
TRB
DMA
DMB
SIG GND
STA
STB
LL
RL
RTA
RSA
RSB
CSA
CSB
Figure B-5. DSL/HSL/SCM Modules to RS-449 (613006-X) (Sheet 2)
CXUG
7-31-98
CXUG
7-31-98
DSL, QSL,
HSL SCM
SDA
SDB
RDA
RDB
RTA
RTB
SIG GND
STA
STB
TTA
TTB
RSA
CSA
DMA
RRA
TRA
LL
RL
TM
20
9
24
10
6
8
4
5
22
14
16
18
19
17
25
7
15
23
13
21
2
11
3
12
26-PIN
MALE
V.35
SHIELD
TX DATA A
TX DATA B
RX DATA A
RX DATA B
RX CLK A
RX CLK B
SIG GND
TX CLK A
TX CLK B
TTA
TTB
RTS
CTS
DSR
RLSD
DTR
LOCAL LOOP
LOOP MAINT
TEST IND
Y
AA
U
W
C
D
E
L
N
F
H
NN
X
B
T
V
S
R
A
P
34-PIN
MALE
Figure B-6. DSL/HSL/SCM Module to V.35 (613003-X) (Sheet 1 of 2)
B-11
B-12
DSL, QSL,
HSL SCM
SDA
SDB
RDA
RDB
RTA
RTB
SIG GND
STA
STB
TTA
TTB
RSA
CSA
DMA
RRA
TRA
LL
RL
TM
20
9
24
10
6
8
4
5
22
14
16
18
19
17
25
7
15
23
13
21
2
11
3
12
26-PIN
MALE
34-PIN
FEMALE
Figure B-6. DSL/HSL/SCM Module to V.35 (613007-X) (Sheet 2)
V.35
SHIELD
TX DATA A
TX DATA B
RX DATA A
RX DATA B
RX CLK A
RX CLK B
SIG GND
TX CLK A
TX CLK B
TTA
TTB
RTS
CTS
DSR
RLSD
DTR
LOCAL LOOP
LOOP MAINT
TEST IND
Y
AA
U
W
C
D
E
L
N
F
H
NN
X
B
T
V
S
R
A
P
CXUG
7-31-98
STL
T1C
2
1
5
4
8-PIN
MODULAR
LINK/2+ BFM/BIM.1,
LINK/100+ DLI.1, entréeLINK+ CSU,
ST-1000/ST-20 Dpanel-4/PRI
CSU/Smart Jack
2
1
5
4
T
R
T
R
TX
RX
8-PIN
MODULAR
Figure B-7. STL Module to LINK/2+ BFM/BIM.1 Modules, LINK 100/+ DLI.1
Module, entréeLINK+ CSU Module, or ST D Panel-4/PRI
(T1M/E1M); T1C to CSU/Smart Jack (Straight) (610127-X)
CXUG
7-31-98
T1C
5
4
2
1
8-PIN
MODULAR
CSU/Smart Jack
(CROSS OVER)
5
4
2
1
T
R
T
R
TX
RX
8-PIN
MODULAR
Figure B-8. T1C to CSU/Smart Jack (Crossover) (610126-X)
B-13
B-14
STL
T1C
4
2
7
5
1
8-PIN
MODULAR
ST-1000/ST-20
DPanel-4/DSX-1
VIA BIM/PBX CABLE
CSU/Smart Jack VIA
DSX-1/CSU CABLE
11
1
2
3
9
T
R
T
R
TX
RX
15-PIN
FEMALE
Figure B-9. STL Module to ST D Panel-4/PRI (T1M/E1M) Via BIM/PBX Cable,
T1C to CSU/Smart Jack (Straight) Via DSX-1/CSU Cable (61362)
STL VIA
BADP CABLE
2
1
3
11
9
15-PIN
MALE
ST-1000/ST-20
DPanel-4/DSX-1
2
1
3
11
9
T
R
T
R
TX
RX
15-PIN
MALE
Figure B-10. STL (Via BADP Cable) to ST D Panel-4/DSX-1 (61359)
CXUG
7-31-98
CXUG
7-31-98
T1C VIA
BADP CABLE
3
11
2
1
9
15-PIN
MALE
CSU/Smart Jack
1
9
2
3
11
T
R
T
R
RX
TX
15-PIN
MALE
Figure B-11. T1C (Via BADP Cable) to CSU/Smart Jack (Crossover) (61385)
DS-3
TO DS3
SERVICE
BNC
MALE
BNC
MALE
Figure B-12. DS-3 Module to DS3 (45 Mbps) Service (120405-X)
OC-3
SC FIBER
CONNECTOR
SINGLE-MODE FIBER
TO FIBER SPLICE
PANEL WITH ST
CONNECTOR COUPLINGS
ST FIBER
CONNECTOR
Figure B-13. OC-3 Module to 155 Mbps (SONET) (Single Mode Fiber) (FOXN0004)
B-15
OC-3
SC FIBER
CONNECTOR
MULTIMODE FIBER
TO FIBER SPLICE
PANEL WITH SC
CONNECTOR COUPLINGS
SC FIBER
CONNECTOR
Figure B-14. OC-3 Module to 155 Mbps (SONET) (Multimode Fiber) (FOXN0005)
B-16
CXUG
7-31-98
CXUG
7-31-98
Appendix
C
Cable Applications
This appendix provides functional application diagrams for all available CX-1500/CX-1540 cables.
CPU MODULE
650252-X
650074-X
650075-X
VT100
TERMINAL
CRAFT
INTERFACE
PORT
610133-X MODEM
Figure C-1. CPU Module Cabling
SCM MODULE
DCE
PORT
613005-X
613006-X
613003-X
613007-X
613008-X
613009-X
RS-449 (DTE)
V.35 (DTE)
RS-530 (DTE)
Figure C-2. SCM Module Cabling
C-1
C-2
DSL, HSL
MODULES
DCE
613004-X
DCE
613005-X
DCE
DCE
DCE
613006-X
613003-X
613007-X
613008-X
613009-X
LINK/2+
OR entréeLINK+
ILC MODULE
LINK/100+
DLI.0 MODULE
OR
RS-449 (DTE)
RS-449 (DTE)
V.35 (DTE)
RS-530 (DTE)
Figure C-3. DSL, HSL Module Cabling
CXUG
7-31-98
CXUG
7-31-98
T1C MODULE
610127-X
CSU/SMART JACK
(STRAIGHT)
610126-X
CSU/SMART JACK
(CROSSOVER)
61362 61385
CSU/SMART JACK
(STRAIGHT)
Figure C-4. T1C Module Cabling
STL MODULE
610127-X
LINK/2+ BFM/BIM.1,
LINK/100+ DLI.1, entréeLINK+ CSU,
ST D-PANEL-4/PRI
61362 61359
ST D-PANEL-4/DSX-1
Figure C-5. STL Module Cabling
C-3
C-4
DS-3 MODULE
120405-X
DS3 (45 Mbps)
FACILITY
Figure C-6. DS-3 Module Cabling
DSC MODULE
DTE
PORT
613008-X
613009-X
RS-530 (DCE)
Figure C-7. DSC Module Cabling
CXUG
7-31-98
OC3 MODULE
FOXN0004
FOXN0005
155 Mbps
SINGLE MODE
SERVICE
(SONET)
155 Mbps
MULTIMODE
SERVICE
(SONET)
Figure C-8. OC3 Module Cabling
CXUG
7-31-98
C-5
CXUG
7-31-98
Appendix
D
Field-Replaceable Units
170401-1
170400-1
170200-1
160203-1
160200-1
160200-2
160200-3
160200-4
160212-1
160212-2
160204-1
160208-1
160210-1
160209-1
160206-1
The tables in this appendix list the replacement parts that are available. Please note that part numbers sometimes change. Each part number should be verified with customer support (or a sales representative) before ordering.
Part Number
160402-1
160400-1
160218-1
160201-1
160401-1
Table D-1. CX-1500/CX-1540 Field-Replaceable Units
Unit Description
CX-1500, 15-Slot Base System
CX-1500, Basic Unit, 15-Slot Chassis with Backplane
CX-1500 Chassis, 15 Slot
CX-1500 Backplane, 15-Slot
CPU Module (included with basic CX-1500 system)
AC Power Supply Unit (included with the base CX-1500/CX-1540 system)
AC Power Supply Unit—Redundant Unit for CX-1500
CX-1540, 4-Slot Base System
CX-1540 Basic Unit, 4-Slot Chassis with Backplane
CX-1540 Chassis, 4-Slot
CX-1540 Backplane, 4-Slot
Station Clock Module (SCM)
OC-3 Interface Module, Multimode, STS (OC3)
OC-3 Interface Module, Single Mode, STS (OC3)
OC-3 Interface Module, Multimode, STM (OC3)
OC-3 Interface Module, Single Mode, STM (OC3)
Structured T-1 Legacy Module, STL-4 (STL)
Structured T-1 Legacy Module, STL-8 (STL)
DS-3 Cell Interface Module (DS3)
Dual Synchronous Cell Interface Module (DSC)
Synchronous Legacy Interface Module—Dual Channel (DSL)
High Sped Synchronous Module (HSL)
T-1 Interface Module (T1C)
D-1
Part No.
650252-X
650074-X
650075-X
610133-X
613008-X
613009-X
613004-X
613005-X
613006-X
613003-X
613007-X
610127-X
610126-X
61362
61359
Table D-2. Field Replaceable Cables
Cable Model Description
CPU-VT100/9F CPU craft interface to VT100 terminal
CPU-VT100/25F
CPU-VT100/25M
ST/NCP-MDM
DSC-530M
DSC-530F
DSL/HSL-ILC
DSL/HSL/SCM-449M
DSL/HSL/SCM-449F
DSL/HSL/SCM-V35M
DSL/HSL/SCM-V35F
ST/MOD-MOD
ST/MOD-XFR
BADP
BIM-PBX-F
CPU craft interface to VT100 terminal
CPU craft interface to VT100 terminal
CPU craft interface to VT100 terminal via modem
DSC Module (DTE) to RS-530 ATM facility
DSL/HSL Modules (DCE) and SCM Module to
V.11 (RS-530)
DSC Module (DTE) to RS-530 ATM facility
DSL/HSL Modules (DCE) and SCM Module to
V.11 (RS-530)
DSL/HSL Modules to LINK/2+ or entréeLINK+ ILC
Module
DSL/HSL Modules to LINK/100+ DLI.0 Module and
RS-449
SCM Module to RS-449
DSL/HSL/SCM Modules to RS-449
DSL/HSL/SCM Modules to V.35 Winchester
DSL/HSL/SCM Modules to V.35 Winchester
STL Module to LINK/2+ BFM/BIM.1, LINK/100+
DLI.1 Module, entréeLINK+ CSU Module, or ST
Dpanel-4/PRI (T1M/E1M)
T1C Module to CSU/Smart Jack (straight)
T1C Module to CSU/Smart Jack (crossover)
STL Module to ST Dpanel-4/DSX-1 via BIM/PBX cable (61359)
T1C Module to CSU/Smart Jack (straight) via
DSX-1/CSU cable (61385)
STL Module (via BADP cable) to ST Dpanel-
4/DSX-1
D-2
CXUG
July 1998
Part No.
61385
120405-X
FOXN0004
FOXN0005
OC3-MM
OC3-SM
Table D-2. Field Replaceable Cables (Cont’d)
Cable Model Description
DSX-1/CSU
TX3-DS3
T1C Module (via BADP cable) to CSU/Smart Jack
DS-3 Module to DS3 (45Mbps) facility (ANSI
T1.107)
OC-3 Module to 155 Mbps multimode service
(SONET)
OC-3 Module to 155 Mbps single mode service
(SONET)
CXUG
7-31-98
D-3
CXUG
7-31-98
Regulatory Requirements
This section contains regulatory information for geographical areas that require specific text to appear in the manual documentation. This equipment has been approved for use in areas other than those listed in this section. For areas not listed below, regulatory requirements and approvals information can be obtained from your local Timeplex office.
The information in this section includes mandatory or recommended requirements of certification authorities for the following areas:
•
Canada
•
United States
NOTE:
All ports on this equipment are Safe Extra Low Voltage (SELV) unless otherwise noted and should only be connected to SELV ports on other equipment.
Reg-1
Canada
Telephone Line Connection Information
The Canadian Department of Communications label identifies certified equipment. This certification means that the equipment meets certain telecommunications network protective, operational, and safety requirements as prescribed in the appropriate Terminal Equipment
Technical Requirements documents. The department does not guarantee the equipment will operate to the user’s satisfaction.
Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications company. The equipment also must be installed using an acceptable method of connection. The customer should be aware that compliance with the above conditions may not prevent degradation of service in some situations.
Repairs to certified equipment should be coordinated by a representative designated by the supplier. Any repairs or alterations made by the user to this equipment, or equipment malfunctions, may give the telecommunications company cause to request the user to disconnect the equipment.
Users should ensure for their own protection that the electrical ground connections of the power utility, telephone lines, and internal metallic water pipe systems, if present, are connected together.
This precaution may be particularly important in rural areas.
CAUTION: Users should not attempt to make such connections themselves, but should contact the appropriate electric inspection authority, or electrician, as appropriate.
The required connection arrangement (telephone jack) for this product is CB1D.
Canadian Compliance Statement
This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of
Communications.
Le présent appareil numérique n’émat pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la classe A prescrites dans le Réglement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada.
CXUG
7-31-98
CAN-1
United States
Federal Communication Commission Part-68 Registration Information
WARNING
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesirable operation. In accordance with FCC Part 15 Subpart B requirements, changes or modifications made to this equipment not expressly approved by Timeplex, Inc. could void user’s authority to operate this equipment.
General Information Regarding the Use of Customer-Provided
Telephone Equipment
FCC regulations and telephone company procedures prohibit connection of customer-provided equipment to telephone company-provided coin service (central office implemented systems).
Connection to party lines service is subject to State tariffs.
The goal of the telephone company is to provide you with the best service it can. To do this, it may occasionally be necessary for them to make changes in their equipment, operation, or procedures. If these changes might affect your service or the operation of your equipment, the telephone company will give you notice, in writing, to allow you to make any changes necessary to maintain uninterrupted service.
If you have any questions about your telephone line, such as how many pieces of equipment you can connect to it, the telephone company will provide this information upon request.
In certain circumstances, it may be necessary for the telephone company to request information from you concerning the equipment that you have connected to your telephone line. Upon request of the telephone company, you must provide the FCC registration number of the equipment that is connected to your line. The FCC registration number is listed on the equipment label.
If this equipment causes harm to the telephone network, the telephone company will notify you in advance that temporary discontinuance of service may be required. If advance notice is not practical, the telephone company will notify the customer as soon as possible. Also, you will be advised of your right to file a complaint with the FCC if you believe it is necessary.
Facility Interface
Codes
04DU9-BN
04DU9-DN
04DU9-1KN
04DU9-1SN
TELECOM INTERFACE PORT CODES
Manufacturer's Port
Identifier Service Order Code
T1C, STL-4, STL-8
T1C, STL-4, STL-8
T1C, STL-4, STL-8
T1C, STL-4, STL-8
6.0F
6.0F
6.0F
6.0F
Network Jacks
RJ48C
RJ48C
RJ48C
RJ48C
CXUG
7-31-98
US-1
Radio Frequency Interference
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at the user’s own expense.
If Problems Arise
If trouble is experienced with this equipment, please contact Timeplex Customer Support at (800)
237-6670 for repair and/or warranty information. If the trouble is causing harm to the telephone network, the telephone company may request that you remove the equipment from the network until the problem is resolved.
The following repairs may be done by the customer: None.
This equipment cannot be used on telephone company-provided coin service. Connection to Party
Line Service is subject to state tariffs.
In the event repairs are ever needed on this equipment, they should be performed by Timeplex, Inc., or an authorized representative of Timeplex, Inc. For information contact:
Timeplex, Inc.
16255 Bay Vista Drive
Clearwater, Florida 34620
1-800-237-6670
US-2
CXUG
7-31-98
A
Alarms, 4-7, 4-13, 5-5, 6-2, 6-5
Anti-Static Procedures, 7-1
ATM Adaptation Layer, A-5
ATM Cell, 1-2, 1-5, 3-1, 3-4, 3-10, 3-14, 3-23,
3-33, 3-37, A-2, A-3
ATM Cell Structure, A-3
ATM Layer, A-4
ATM Networks, A-1
ATM Reference Model, A-3, A-4
B
Bus Timing, 1-9
C
Cell Bus, 1-2, 1-5, 3-4, 3-10, 3-14, 3-19, 3-22,
3-23, 3-33, 3-37
Cell Exchange, 1-1
Channel Timing, 1-9
Chassis, 1-12, 2-1, 2-2, 2-3
Chassis Installation, 2-1
Command Operation, 4-6
Command Parameter Entry, 4-6
Command Response, 4-7
Configuration, 3-1, 5-4, 5-9, 5-10
Configuring Interface Connections, 5-8
Connection Management, 5-8
CPU Module, 1-5, 1-6, 3-1, 3-3, 3-4, 6-1, 7-3, 7-
4
CX-1500 Chassis, 1-4
CX-1540 Chassis, 1-5
D
Diagnostics, 4-7
DS-3 Cell Interface Module, 3-2
Dual Channel High Speed Synchronous Legacy
Interface Module, 1-7, 3-22
Dual Channel Synchronous Cell Interface
Module, 3-2
CXUG
7-31-98
Index
Dual Channel Synchronous Cell Module, 3-19
E
Electrostatic Discharge, 7-1, 7-3, 7-4
Equipment Description, 1-4
Equipment Installation, 2-1
F
Field-Replaceable Units, 11-1
Front Panel Indicators, 1-6
Fuse, 7-5, 7-6
G
General Troubleshooting, 6-1
Grounding, 2-2
H
High Speed Synchronous Legacy Interface
Module, 3-36
I
Installation, 2-1
Interface Modules, 1-2, 1-4, 1-7, 7-4
K
Keystroke Correction, 4-6
L
Local Management Station, 4-3
Location Name, 5-1, 5-2
Logon, 4-3
IN-1
M
Main Menu Screen, 4-5
Menu Selection, 4-5
Microprocessor, 1-5
Module Installation, 2-3
Module Summary, 3-1
Modules and Services, 1-2
N
Network Loopback, 6-7
Network Management, 1-6
O
OC-3 Cell Module, 3-15, 3-19
P
Passwords, 4-3, 4-4
Performance Characteristics, 1-11
Physical Interfaces, 5-2
Physical Layer, A-4
Power Connections, 2-2
Power Distribution, 1-6
Power Supply Module, 1-6, 3-1, 3-6, 6-1, 7-2, 7-
3
Preventive Maintenance, 4-5
Quality of Service, A-5
Q
R
Repair and Replacement, 7-1
Replacing Chassis, 7-1
Replacing Modules, 7-2
Required Tools and Equipment, 2-1
S
SCM, 3-8
Setting System Timing, 5-6
Site Preparation, 2-1
Software Version, 5-6, 5-7
Station Clock Interface Module, 3-8
Synchronous Legacy Interface Module, 3-32
Synchronous Legacy Interface Modules, 3-32
System Cooling, 1-11
System Reset Window, 4-9
System Timing, 1-7, 1-8, 5-6
T
Troubleshooting, 6-1
U
Unpacking, 2-1
V
Virtual Channel Identifier, 5-5, 5-9, A-2, A-3
Virtual Path Identifier, 5-5, 5-9, A-1, A-2, A-3,
A-4
IN-2
CXUG
7-31-98