Transmitter x100e Series for pH, Dissolved Oxygen and Conductivity
Advanced transmitters for reliable measurements and for harsh conditions
Technical Data
Short description
The cost-effective Transmitter X100 Series are suitable designed for highly reliable and accurate measurements in a wide range of industrial applications. The instruments are easy to operate and the large-size
LCD provides substantial all essential information. The measurement values are displayed in large characters and additional pictographs explain the function operation and advise any signal or functional irregularities.
Features
– Two 0/4…20 mA current outputs
– Two limit contacts
– Alarm & wash contact
– Continuous monitoring of sensor and transmitter performance
– Sensor diagnostics
– Easy operation with help of pictographs
– PID controller
– Communication with EasyClean, the METTLER TOLEDO cleaning
Drawings
Specifications transmitter pH 2100e
Specifications transmitter O
2
4100e
Specifications transmitter O
2
4100ppb
Specifications transmitter Cond 7100e
Specifications transmitter Cond Ind 7100e
Terminal assignment «Advanced Line» transmitters
General specifications «Advanced Line» transmitters
Ordering information
8
10
12
14
17
6
7
2
4
2
Drawings
Assembly
Mounting
1
2
10
9
3
4 5 6 7
144 105
27
12
11
8
1 Sealing plugs
2 Hexagon nuts
3 Pg cable glands
4 Rubber reducer
5 Pg plug
6 Enclosure screws
7 Hinge pin
8 Cable ties
9 Filler plugs
10 Gaskets
11 Washer
12 Jumper
1 Cable gland (3 pieces)
2 Breakthroughs for cable gland or conduit 1 /
2
",
Ø 21.5 mm
(2 breakthroughs).
Conduits not included!
3 Holes for post mounting
4 Holes for wall mounting
32
42
84
80
21
43
2
Drawings
Pipe mounting with ZU 0274 bracket kit
40 – 60 mm dia.
2
3
4
132 mm
1
5
Protective hood ZU 0276 for wall and pipe mounting
165 mm 132 mm
1 Protected hood
(if required)
2 Hose clamps with worm gear drive to DIN 3017
(2 pieces)
3 Postmounting plate
4 For vertical or horizontal post/pipe mounting
5 Self-tapping screws
Panel-mount kit ZU 0275 max. 25
78 27
1
5 4
2
3
1 Screws
2 Seal
3 Control panel
4 Span pieces
5 Threaded sleeves
3
4
Specifications Transmitter pH 2100e pH/mV input Input for pH, ORP electrodes or ISFET
Measurement range –1500…+1500 mV
Display range pH value –2.00…16.00
ORP –1999…+1999 mV
Glass electrode input 1)
Input resistance
Input current
Reference electrode input 1)
> 0.5 x 10
< 2 x 10
12
–12 A
Ω
Input resistance
Input current
Meas. error 1,2,3) pH value mV value
> 1 x 10 10 Ω
< 1 x 10 –10 A
< 0.02
< 1 mV
Electrode
standardization pH *
Operating modes
Zero point adjustment
Max. calibration range
-BUF Calibration with automatic buffer recognition Calimatic:
Buffer sets -01Mettler-Toledo 2.00/4.01/7.00/9.21
-02Merck/Riedel de Haen 2.00/4.00/7.00/9.00/12.00
-03Ciba (94) 2.06/4.00/7.00/10.00
-04NIST technical 1.68/4.00/7.00/10.01/12.46
-05NIST standard 1.679/4.006/6.865/9.180
-06HACH 4.00/7.00/10.18
-07WTW technical buffers 2.00/4.01/7.00/10.00
-PRD
-MAN
-DAT
±200 mV
Product Calibration
Calibration with manual entry of individual buffer values
Data entry of premeasured electrodes
Asymmetry potential: ±60 mV
Slope: 80…103 % (47.5…61 mV/pH)
Sensor standardization
ORP*
Max. calibration range
Cal timer
Sensocheck
Sensoface
ORP calibration
–700…+700 D mV
0000…9999 h automatic monitoring of glass and reference electrode (can be disabled) provides information on the electrode condition.
Evaluation of zero/slope, response, calibration interval, Sensocheck
Specifications
Temperature input *
Measurement range
Adjustment range
Resolution
Meas. error 1,2,3)
Temp. compensation of process medium
Power output
Transmitter pH 2100e
Pt100/Pt1000/NTC 30 kΩ / NTC 8,55 kΩ
2-wire connection, adjustable
Pt100/Pt1000:
NTC 30 kΩ
NTC 8.55 kΩ
–20.0…+ 200.0 °C/–4…+ 392 °F
– 20.0…+ 150.0 °C/–4…+ 302 °F
–10.0…+ 130.0 °C/+14…+ 266 °F
10 K
0.1 °C/1 °F
< 0.5 K (< 1 K for Pt100; <1K for NTC >100 °C)
Linear –19.99…+19.99 %/K
(reference temp. 25 °C) for operating an ISFET adapter
+ 3 V/0.5 mA
– 3 V/0.5 mA
* User-defined
1) To IEC 746 Part 1, at nominal operating conditions
2)
3)
± 1 count
Plus sensor error
5
6
Specifications Transmitter O
2
4100e
Dissolved oxygen input
Sensor type A:
Sensor type B:
Measuring current
Resolution
InPro6000…6800
InPro6900
-2…1800 nA
0.05 nA (with Vpol ≤ 800 mV and Vref ≤ 200 mV)
Saturation (–10…80 °C) 0…500 %
Meas. error 1,2,3) 0.5 % of meas. val. +0.5 %
Concentration (–10…80 °C) 0.00…50.00 mg/l
0.00…50.00 ppm
Meas. error 1,2,3) 0.5 % of meas. val. + 0.05 mg/l
Adm. guard current
Polarization voltage *
Process pressure* or 0.05 ppm
20 µA
0…1000 mV
0.000…9.999 bar
Salt correction *
(…999.9 kPa/…145.0 psi)
00.00…45.00 g/kg
Sensor standardization
Operating modes *
Calibration range
Sensor type A
Calibration range
Sensor type B
Calibration timer *
Pressure correction *
DO saturation (automatic)
DO concentration (automatic)
Product calibration
Zero point calibration
Zero point
Slope
± 2 nA
25…130 nA
(at 25 °C, 1013 mbars)
± 2 nA Zero point
Slope 200…550 nA
(at 25 °C, 1013 mbars)
0000…9999 h
0.000…9.999 bars/999.9 kPa/145.0 psi
Sensocheck
Sensoface
Monitoring for short circuits/open circuits (can be disabled)
Provides information on the sensor condition
Evaluation of zero/slope, response, calibration interval, Sensocheck
Temperature input *
Measurement range
Adjustment range
Resolution
Meas. error 1,2,3)
NTC 22 kΩ / NTC 30 kΩ*
2-wire connection, adjustable
– 20.0…+150.0 °C/– 4…+ 302 °F
10 K
0.1 °C/1 °F
< 0.5 K (< 1 K at >100 °C)
* User-defined
1) To IEC 746 Part 1, at nominal operating conditions
2)
3)
± 1 count
Plus sensor error
Specifications Transmitter O
2
4100ppb
Dissolved oxygen input
Sensor type A:
Sensor type B:
Measuring current
Resolution
InPro6000…6800
InPro6900
-2…600 nA
0.01 nA (with Vpol ≤ 500 mV and Vref ≤ 200 mV)
Saturation (–10…80 °C) 0.0.…120.0 %
Meas. error 1,2,3) 0.5 % of meas. val. +0.1 %
Concentration (–10…80 °C) 0000…9999 µg/l
0000…9999 ppb
0.0000…9.999 mg/l
0.0000…9.999 ppm
Meas. error 1,2,3) 0.5 % of meas. val. +0.005 mg/l or 0.005 ppm
Adm. guard current
Polarization voltage*
Process pressure*
Salt correction*
20 µA
0…1000 mV
0.000…9.999 bars
(to 999.9 kPa/…145.0 psi)
00.00…45.00 g/kg
Sensor standardization
Operating modes *
Calibration range
Sensor type A
Calibration range
Sensor type B
Calibration timer *
Pressure correction *
Sensocheck
Sensoface
DO saturation (automatic)
DO concentration (automatic)
Product calibration
Zero point calibration
Zero point
Slope
± 2 nA
25…130 nA
(at 25 °C, 1013 mbars)
± 2 nA Zero point
Slope 200…550 nA
(at 25 °C, 1013 mbars)
0000…9999 h
0.000…9.999 bars/999.9 kPa/145.0 psi
Monitoring for short circuits/open circuits (can be disabled)
Provides information on the sensor condition
Evaluation of zero/slope, response, calibration interval, Sensocheck
Temperature input *
Measurement range
Adjustment range
Resolution
Meas. error 1,2,3)
NTC 22 kΩ/ NTC 30 kΩ*
2-wire connection, adjustable
–20.0…+150.0 °C/–4…+302 °F
10 K
0.1 °C/1 °F
< 0.5 K (< 1 K at >100 °C)
* User-defined
1) To IEC 746 Part 1, at nominal operating conditions
2)
3)
± 1 count
Plus sensor error
7
8
Specifications
Conductivity input
Working range
Effective ranges
Measurement error 1,2,3)
Conc. measurements
Sensor standardization
Permissible cell constant
Sensocheck
Sensoface
Sensor monitor
USP-Function
Transmitter Cond 7100e
Input for 2-e or 4-e conductivity sensors
4-electrode sensor: 0.2 µS *c …1000 mS * c (c = cell constant)
2-electrode sensor: 0.2 µS *c …200 mS * c
(the actual range is very much depending on the sensor used, display limited to 3500 mS)
Conductivity 0.000…9.999 µS/cm
00.00…99.99 µS/cm
000.0…999.9 µS/cm
0000…9999 µS/cm
0.000…9.999 mS/cm
00.00…99.99 mS/cm
000.0…999.9 mS/cm
0.000…9.999 S/m
00.00…99.99 S/m
Resistivity
Concentration
00.00…99.99 MΩcm
0.00…9.99 % by wt.
Salinity 0.0…45.0 ‰ (0…35 °C)
< 1% of measured value +0.4 µS * c
-01- NaCl
-02- HCl
0.00…9.99 % by wt.
(0 …60°C)
0.00…9.99 % by wt.
(–20…50 °C)
-03- NaOH 0.00…9.99 % by wt.
(0…100 °C)
-04- H
2
SO
-05- HNO
3
4
0.00…9.99 % by wt.
(–17…110 °C)
0.00…9.99 % by wt.
(–17…50 °C)
Input of cell constant with simultaneous display of conductivity value and temperature
Input of conductivity value with simultaneous display of cell constant and temperature
Product calibration
Temperature probe adjustment
00.0050…19.9999 cm –1
Monitoring of sensor polarization and cable capacitance (can be disabled)
Provides information on the sensor condition (Sensocheck)
Display of direct measurement values for validation purpose (resistance/temperature)
Monitoring of conductivity of water for pharmaceutical applications to USP (USP <645>) with adjustable limit values (10…100 % of USP value)
Specifications Transmitter Cond 7100e
Temperature input
Measuring range
*) Pt100/Pt1000/NTC 30 kΩ / NTC 8.55 kΩ
2-wire connection, adjustable
Pt100/Pt1000
NTC 30 kΩ
NTC 8.55 kΩ
0.1 °C / 1 °F
–20…+200 °C / –4…+392 °F
–20…+150 °C / -4…+302 °F
–10…+130 °C / +14…+266 °F
Resolution
Error 1,2,3) 0.5 K (< 1 K with Pt100; < 1 K with NTC > 100 °C)
Temperature compensation (OFF) not compensated
(ref. temp. 25 °C) (Lin) linear, 0.00…19.99 %/K, –20…130 °C
(NLF) natural waters to EN 27888, 0…36 °C
(nACL) ultrapure water with NaCl traces, 0…120 °C
(HCL) ultrapure water with HCl traces,
(nH3) ultrapure water with NH
3 traces,
0…120 °C
0…120 °C
* User-defined
1) To IEC 746 Part 1, at nominal operating conditions
2)
3)
± 1 count
Plus sensor error
9
10
Specifications
Conductivity input
Working range
Effective ranges
Measurement error 1,2,3)
Conc. measurements
Sensor standardization
Transmitter Cond Ind 7100e
Input for inductive sensors
Conductivity 0.000…1999 mS/cm
Concentration
Salinity
Conductivity
0.00…100 % by wt.
0.0…45.0 ‰ (0…35 °C)
0.000…9.999 mS/cm
00.00…99.99 mS/cm
000.0…999.9 mS/cm
0000…1999 mS/cm
0.000…9.999 S/m
00.00…99.99 S/m
Concentration
Salinity
0.00…99.99 %
0.0…45.0 ‰ (0…35 °C)
< 1% of measured value +0.005 mS
-01- NaCl
-02- HCl
0…26 % (0…60 °C)
0…18 % (–20…50 °C)
-03- NaOH 0…14 % (0…100 °C)
-04- H
2
SO
4
-05- HNO
3
-06- H
2
SO
-07- HCl
4
0…30 % (–17…110 °C)
0…30 % (–20…50 °C)
92…99 % (–17…115 °C)
22…39 % (–20…50 °C)
-08- HNO
3
-09- H
2
SO
4
35…96 % (–20…50 °C)
32…84 % (–17…115 °C)
-10- NaOH 18…50 % (0…100 °C)
Input of cell factor with simultaneous display of conductivity value and temperature
Input of conductivity value with simultaneous display of cell factor and temperature
Product calibration
Zero point calibration
Temperature probe adjustment
00.100…19.999
01.00…199.99
Permissible cell factor
Permissible transfer ratio
Permissible zero point deviation
Sensocheck
Sensoface
Sensor monitor
± 0.5 mS/cm
Monitoring of sender coil and leads for short circuiting, and of the receiver coil for disruption (can be disabled)
Indicates sensor status (zero point, sensocheck)
Display of direct measurement values for validation purpose (resistance /temperature)
Specifications Transmitter Cond Ind 7100e
Temperature input
Measuring range
* Pt100/Pt1000/NTC 100 kΩ
2-wire connection, adjustable
Pt100/Pt1000 –20…+200 °C / –4… +392 °F
NTC –20…+130 °C / –4… +266 °F
0.1 °C / 1 °F Resolution
Error 1,2,3) 0.5 K (< 1 K with Pt100; < 1 K with NTC > 100 °C)
Temperature compensation (OFF) not compensated
(ref. temp. 25 °C) (LIN) linear, 0.00…19.99 %/K
(NLF) natural waters to EN 27888 (0…35 °C)
* User-defined
1)
2)
To IEC 746 Part 1, at nominal operating conditions
± 1 count
3) Plus sensor error
11
12
Terminal assignment
Transmitter pH 2100 e
Transmitter O
2
4100 e
Transmitter O
2
4100 ppb
«Advanced Line» transmitters
Terminal assignment
Transmitter Cond 7100e
Transmitter Cond Ind 7100e
«Advanced Line» transmitters
13
14
General specifications
HOLD input
Function
Switching voltage
CONTROL input pH/O
2
Function
)
Switching voltage
CONTROL input (Cond)
Function
Switching voltage
Output 1
Process variable *
Current characteristics*
Overrange *
Output filter *
Meas. error
1)
Start/end of scale
Adm. span
Output 2
Process variable
Overrange *
Output filter *
Meas. error 1)
Start/end of scale *
Adm. span
Alarm contact
Contact ratings
Contact response
Alarm delay
«Advanced Line» transmitters
Galv. separated (OPTO coupler)
Switches device to HOLD state
0…2 V (AC/DC) hold inactive
10…30 V (AC/DC) hold active
Galv. separated (OPTO coupler)
Control input for automatic cleaning/calibration system
0…2 V (AC/DC) inactive
10…30 V (AC/DC) active
Galv. separated (OPTO coupler)
Switches between two parameter sets
0…2 V (AC/DC) set #1 active
10…30 V (AC/DC) set #2 active
0/4…20 mA, max. 10 V, floating
(galv. connected to output 2) pH 2100 e
O
2
O
2
4100e
4100 ppb
Cond 7100e pH/mV
%, mg/l
%, mg/l conductivity, resistivity, concentration, salinity
Cond Ind 7100e conductivity, concentration, salinity linear or logarithmic (depends on transmitter)
22 mA in the case of error message
Low-pass, filter time constant 0…120 s
< 0.3 % of current value +0.05 mA
As desired within measuring range pH 2100e
0
2
0
2
4100e
4100 ppb
Cond 7100e
2.00…18.00/200…3000 mV
5…500 %, 0.5…50 mg/l
2…200 %, 0.2…10 mg/l
LIN 5 % of selected measuring range
LOG 1 decade
Cond Ind 7100e LIN 5 % of selected measuring range
LOG 1 decade
0/4…20 mA, max. 10 V, floating
(galv. connected to output 1)
Temperature
22 mA in the case of temp error messages
Low-pass, filter time constant 0…120 s
< 0.3 % of current value + 0.05 mA pH, Cond: –20…+200 °C/–4…+392 °F, 0
2 pH, Cond: 20…320 K, 0
2
: 20…170 K
: –20…+150 °C/–4...+302 °F
Relay contact, floating
AC < 250 V/< 3 A/< 750 VA
DC < 30 V/< 3 A/< 90 W
N/C (fail-safe type)
0000…0600 s
General specifications «Advanced Line» transmitters
Limit values
Contact ratings
Contact response *
Delay *
Switching points *
Hysteresis *
PID process controller
Setpoint specification *
Neutral zone *
P-action *
I-action component *
D-action component *
Output via relay contacts R1, R2
Contacts R1, R2 floating, but inter-connected
AC < 250 V/< 3 A/< 750 VA
DC < 30 V/< 3 A/< 90 W
N/C or N/O
0000…9999 s
As desired within measuring range pH 2100e 0…5.00 pH/0…500 mV
0
2
0
2
4100e
4100ppb
Cond 7100e
0…50 %/0…5.00 mg/l (ppm)
0…50 %/0…5.00 mg/l (ppm)
0…50 % of measuring range
Cond Ind 7100e 0…50 % of measuring range
Output via relay contacts R1, R2 (see limit values) pH 2100e –02.00…16.00/– 1500…+1500 mV
0
2
0
2
4100e
4100ppb
Cond 7100e
0…500 % / 0…50 mg/l
0…120% / 0…9.999 mg/l within selected measuring range
Cond Ind 7100e within selected measuring range pH 2100e
0
2
0
2
4100e
4100ppb
Cond 7100e
0…5.00 pH / 0…+500 mV
0…50 % / 0…5 mg/l
0…50 % / 0…5 mg/l (ppm) within selected measuring range
Cond Ind 7100e max. 50 % of selected measuring range
Controller gain K
Reset time Tr:
R
: 0010…9999 %
0000…9999 s
(0000 s = no integral action)
Derivative-action time Td: 0000…9999 s
(0000 s = no derivative action)
Pulse length controller or pulse frequency controller
0001…0600 s, min. ON time 0.5 s (pulse length controller)
0001…0180 min –1 (pulse frequency controller)
Controller type*
Pulse period *
Max. pulse frequency *
Cleaning function/
2 nd parameter set
Contact ratings
Contact response *
Rinsing interval *
Cleaning time *
Calibration interval *
Cleaning interval*
Relay contact, floating for controlling a simple rinsing system or an automatic cleaning system or to show that 2 nd parameter set is active
AC < 250 V/< 3 A/< 750 VA
DC < 30 V/< 3 A/< 90 W
N/C or N/O (cleaning function)
N/O (2 nd parameter set)
000.0…999.9 h
(000.0 h = cleaning function switched off)
0000…1999 s
000.0…999.9 h
000.0…999.9 h
* User-defined
1)
2)
To IEC 746 Part 1, at nominal operating conditions
± 1 count
3) Plus sensor error
15
16
General specifications «Advanced Line» transmitters
Display
Main display
Secondary display
Sensoface
Mode indicators
Alarm indication
Keypad
Service functions
Current source
Manual controller
Device self-test
Display test
Last Error
Sensor monitor
Relay test
Parameter sets*
Data retention
EMC
Lightning protection
LC display, 7-segment with icons
Character height 17 mm, unit symbols 10 mm
Character height 10 mm, unit symbols 7 mm
3 status indicators (friendly, neutral, sad smiley)
5 status bars: «meas», «cal», «alarm», «cleaning», «config»
18 further icons for configuration and messages
Red LED in case of alarm or HOLD, user defined
5 keys: [cal] [conf] [ ] [ ] [enter]
Current specifiable for output 1 and 2 (00.00…22.00mA)
Controller output entered directly (start of control process)
Automatic memory test (RAM, FLASH, EEPROM)
Display of all segments
Display of last error occurred
Display of direct, uncorrected sensor signal (electrode/sensor)
Manual control of the four switching contacts
Two selectable parameter sets for different applications
Parameters and calibration data > 10 years (EEPROM)
EN 61326
EN 61326/A1
EN 61000-4-5, Installation Class 2
Protection against electrical shock
FM/CSA
Power supply
Protective separation of all extra-low-voltage circuits against mains as per EN 61010
NI, Class 1, Div 2, Group A, B, C, D, T4
24 (–15%)…230 (+10%) V AC/DC; approx. 5 VA, 2.5 W
AC: 45…65 Hz
Overvoltage category II, Class II
Nominal operating conditions
Ambient temperature – 20…+55 °C / –4...+131 °F
Transport/Storage temp
Relative humidity
– 20…+70 °C / -4...+158 °F
10…95 % non condensing
Power supply
Frequency for AC
24 (–15%)…230 (+ 10 %) V AC/DC
45…65 Hz
General specifications and ordering information «Advanced Line» transmitters
Enclosure
Color
Assembly
Dimensions
Ingress protection
Cable glands
Weight molded enclosure made of PBT (polybutylene terephtalate)
Bluish gray RAL 7031
• Wall mounting
• Pipe mounting: Ø 40…60 mm, Ø 30…45 mm
• Panel mounting, cutout to DIN 43 700, sealed against panel
H x W x L: 144 x 144 x 105 mm (5.67 x 5.67 x 4.13")
IP 65/NEMA 4X
3 breakthroughs for cable glands M20 x 1.5
2 breakthroughs for NPT approx. 1 kg
* User-defined
1) To IEC 746 Part 1, at nominal operating conditions
2)
3)
± 1 count
Plus sensor error
1 /
2
" or Rigid Metallic Conduit
Ordering information
Description
4-wire instruments (20…253 V AC/DC)
Transmitter pH 2100e
Transmitter O
Transmitter O
2
4100e
2
4100ppb
Transmitter Cond 7100e
Transmitter Cond Ind 7100e
Installation accessories
Bracket kit
Panel-mount kit
Protective hood
Designation pH 2100e
O
2
O
2
4100e
4100ppb
Cond 7100e
Cond Ind 7100e
ZU 0274
ZU 0275
ZU 0276
Order number
52 121 102
52 121 103
52 121 104
52 121 126
52 121 127
52 120 741
52 120 740
52 120 739
17
18
Notes
Notes
19
METTLER TOLEDO Market Organizations
Sales and Service:
Australia
Mettler-Toledo Ltd.
220 Turner Street
Port Melbourne
AUS-3207 Melbourne/VIC
Phone +61 1300 659 761
Fax +61 3 9645 3935 e-mail [email protected]
Austria
Mettler-Toledo Ges.m.b.H.
Südrandstraße 17
A-1230 Wien
Phone +43 1 604 19 80
Fax +43 1 604 28 80 e-mail [email protected]
Brazil
Mettler-Toledo Ind. e Com. Ltda.
Avenida Tamboré, 418
Tamboré
BR-06460-000 Barueri/SP
Tel.
Fax
+55 11 4166 7400
+55 11 4166 7401 e-mail [email protected]
China
Mettler-Toledo Instruments
(Shanghai) Co. Ltd.
589 Gui Ping Road
Cao He Jing
CN-200233 Shanghai
Phone +86 21 64 85 04 35
Fax +86 21 64 85 33 51 e-mail [email protected]
Croatia
Mettler-Toledo d.o.o.
Mandlova 3
HR-10000 Zagreb
Phone +385 1 292 06 33
Fax +385 1 295 81 40 e-mail [email protected]
Czech Republic
Mettler-Toledo s.r.o.
Trebohosticka 2283/2
CZ-100 00 Praha 10
Phone +420 2 72 123 150
Fax +420 2 72 123 170 e-mail [email protected]
Denmark
Mettler-Toledo A/S
Naverland 8
DK-2600 Glostrup
Phone +45 43 27 08 00
Fax +45 43 27 08 28 e-mail [email protected]
France
Mettler-Toledo
Analyse Industrielle S.A.S.
30, Boulevard de Douaumont
F-75017 Paris
Phone +33 1 47 37 06 00
Fax +33 1 47 37 46 26 e-mail [email protected]
Germany
Mettler-Toledo GmbH
Prozeßanalytik
Ockerweg 3
D-35396 Gießen
Phone +49 641 507 333
Fax +49 641 507 397 e-mail [email protected]
Great Britain
Mettler-Toledo LTD
64 Boston Road, Beaumont Leys
GB-Leicester LE4 1AW
Phone +44 116 235 7070
Fax +44 116 236 5500 e-mail [email protected]
Hungary
Mettler-Toledo Kereskedelmi KFT
Teve u. 41
HU-1139 Budapest
Phone +36 1 288 40 40
Fax +36 1 288 40 50 e-mail [email protected]
India
Mettler-Toledo India Private Limited
Amar Hill, Saki Vihar Road
Powai
IN-400 072 Mumbai
Phone +91 22 2857 0808
Fax +91 22 2857 5071 e-mail [email protected]
Italy
Mettler-Toledo S.p.A.
Via Vialba 42
I-20026 Novate Milanese
Phone +39 02 333 321
Fax +39 02 356 2973 e-mail [email protected]
Japan
Mettler-Toledo K.K.
Process Division
6F Ikenohata Nisshoku Bldg.
2-9-7, Ikenohata
Taito-ku
JP-110-0008 Tokyo
Phone +81 3 5815 5606
Fax +81 3 5815 5626 e-mail [email protected]
Malaysia
Mettler-Toledo (M) Sdn Bhd
Bangunan Electroscon Holding, U 1-01
Lot 8 Jalan Astaka U8/84
Seksyen U8, Bukit Jelutong
MY-40150 Shah Alam Selangor
Phone +60 3 78 44 58 88
Fax +60 3 78 45 87 73 e-mail
Mexico
Mettler-Toledo S.A. de C.V.
Ejercito Nacional #340
Col. Chapultepec Morales
Del. Miguel Hidalgo
MX-11570 México D.F.
Phone +52 55 1946 0900 e-mail [email protected]
Poland
Mettler-Toledo (Poland) Sp.z.o.o.
ul. Poleczki 21
PL-02-822 Warszawa
Phone +48 22 545 06 80
Fax +48 22 545 06 88 e-mail [email protected]
Russia
Mettler-Toledo Vostok ZAO
Sretenskij Bulvar 6/1
Office 6
RU-101000 Moscow
Phone +7 495 621 56 66
Fax +7 495 621 63 53 e-mail [email protected]
Singapore
Mettler-Toledo (S) Pte. Ltd.
Block 28
Ayer Rajah Crescent #05-01
SG-139959 Singapore
Phone +65 6890 00 11
Fax +65 6890 00 12
+65 6890 00 13 e-mail [email protected]
Slovakia
Mettler-Toledo s.r.o.
Hattalova 12/A
SK-83103 Bratislava
Phone +421 2 4444 12 20-2
Fax +421 2 4444 12 23 e-mail [email protected]
Slovenia
Mettler-Toledo d.o.o.
Pot heroja Trtnika 26
SI-1261 Ljubljana-Dobrunje
Phone +386 1 530 80 50
Fax +386 1 562 17 89 e-mail [email protected]
South Korea
Mettler-Toledo (Korea) Ltd.
Yeil Building 1 & 2 F
124-5, YangJe-Dong
SeCho-Ku
KR-137-130 Seoul
Phone +82 2 3498 3500
Fax +82 2 3498 3555 e-mail [email protected]
Spain
Mettler-Toledo S.A.E.
C/Miguel Hernández, 69-71
ES-08908 L’Hospitalet de Llobregat
(Barcelona)
Phone +34 902 32 00 23
Fax +34 902 32 00 24 e-mail [email protected]
Sweden
Mettler-Toledo AB
Virkesvägen 10
Box 92161
SE-12008 Stockholm
Phone +46 8 702 50 00
Fax +46 8 642 45 62 e-mail [email protected]
Switzerland
Mettler-Toledo (Schweiz) GmbH
Im Langacher
Postfach
CH-8606 Greifensee
Phone +41 44 944 45 45
Fax +41 44 944 45 10 e-mail [email protected]
Thailand
Mettler-Toledo (Thailand) Ltd.
272 Soi Soonvijai 4
Rama 9 Rd., Bangkapi
Huay Kwang
TH-10320 Bangkok
Phone +66 2 723 03 00
Fax +66 2 719 64 79 e-mail
USA/Canada
Mettler-Toledo Ingold, Inc.
36 Middlesex Turnpike
Bedford, MA 01730, USA
Phone +1 781 301 8800
Freephone +1 800 352 8763
Fax e-mail
+1 781 271 0681 [email protected]
ISO
9001 certified
ISO
14001 certified
Management System certified according to
ISO 9001 / ISO 14001
Subject to technical changes.
© Mettler-Toledo AG, Process Analytics
08/13 Printed in Switzerland. 52 121 132
Mettler-Toledo AG, Process Analytics
Im Hackacker 15, CH–8902 Urdorf
Tel. + 41 44 729 62 11, Fax +41 44 729 66 36 www.mt.com
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement