Imagine Communications 6800+ VSD, VSE Standard Serial Digital Video Distribution Amplifier Installation and Operation Manual
광고
광고
Installation and Operation Manual
VSD/VSE6800+
Standard Serial Digital Video
Distribution Amplifiers
Edition C
175-000149-00
Delivering the Moment
Publication Information
© 2014 Imagine Communications Corp. Proprietary and Confidential.
Imagine Communications considers this document and its contents to be proprietary and confidential. Except for making a reasonable number of copies for your own internal use, you may not reproduce this publication, or any part thereof, in any form, by any method, for any purpose, or in any language other than English without the written consent of Imagine Communications. All others uses are illegal.
This publication is designed to assist in the use of the product as it exists on the date of publication of this manual, and may not reflect the product at the current time or an unknown time in the future. This publication does not in any way warrant description accuracy or guarantee the use for the product to which it refers. Imagine Communications reserves the right, without notice to make such changes in equipment, design, specifications, components, or documentation as progress may warrant to improve the performance of the product.
Trademarks
6800+™, ADC™, CCS Navigator™, Channel ONE™, ChannelView™, ClipSync™, Delay™, D Series™, D Series DSX™, Deliver the Moment™, Delivering the Moment™, FAME™, Farad™, G8™, G Scribe™, HView™, IconMaster™, IconLogo™, IconStation™, IconKey™, InfoCaster™, InfoCaster Creator™, InfoCaster Manager™, InfoCaster Player™, InstantOnline™, Invenio®,
Live Update™, mCAPTURE™, Magellan™, Magellan CCS Navigator™, Magellan Q SEE™, MultiService SDN™, NetPlus™,
NetVX™, NewsForce™, Nexio® G8™, Nexio AMP® ChannelView™, Nexio® Channel ONE™, Nexio® ClipSync™, Nexio®
Delay™, Nexio® Digital Turnaround Processor™, Nexio® Farad™, Nexio® G Scribe™, Nexio® IconKey™, Nexio® IconLogo™,
Nexio® IconMaster™, Nexio® IconStation™, Nexio® InfoCaster™, Nexio® InfoCaster Creator™, Nexio® InfoCaster Manager™, Nexio® InfoCaster Player™, Nexio® InfoCaster Traffic™, Nexio® InstantOnline™, Nexio® mCAPTURE™, Nexio® News-
Force™, Nexio® NXIQ™, Nexio® Playlist™, Nexio® Remote™, Nexio®RTX Net™, Nexio® TitleMotion™, Nexio® TitleOne™,
Nexio® Velocity ESX™, Nexio® Velocity PRX™, Nexio® Velocity XNG™, Nexio® Volt™, OPTO+™, Panacea™, Platinum™,
Playlist™, Predator II GRF™, Predator II GX™, Punctuate™, Remote™, RTX Net™, QuiC™, Q SEE™, SD STAR™, Selenio™,
Selenio 6800+™, SelenioNext™, Selenio X50™, Selenio X85™, Selenio X100™, TitleMotion™, TitleOne™, Velocity ESX™,
Velocity PRX™, Velocity XNG™, Versio™, Videotek® SD STAR™, X50™, and X85™ are trademarks of Imagine Communications or its subsidiaries.
Altitude Express®, Connectus®, Enabling PersonalizedTV®, ICE® Broadcast System, ICE Illustrate®, ICE Q® algorithms, ICE-
PAC®, Imagine ICE®, Inscriber®, Inscriber® Connectus®, Invenio®, NEO®, Nexio®, Nexio AMP®, PersonalizedTV®, Router-
Works®, Videotek®, Videotek® ASI STAR®, Videotek® GEN STAR®, and Videotek® HD STAR® are registered trademarks of
Imagine Communications or its subsidiaries.
Microsoft® and Windows® are registered trademarks of Microsoft Corporation. HD BNC is a trademark of Amphenol
Corporation. Some products are manufactured under license from Dolby Laboratories. Dolby and the double D symbol are registered trademarks of Dolby Laboratories. DTS Neural audio products are manufactured under license from DTS
Licensing Limited. DTS and the Symbol are registered trademarks & the DTS Logos are trademarks of DTS, Inc. © 2008
2010 DTS, Inc. All other trademarks and trade names are the property of their respective companies.
Contact Information
Imagine Communications has office locations around the world. For locations and contact information see:
http://www.imaginecommunications.com/contact us/
Support Contact Information
For support contact information see:
▪
▪ Support Contacts: http://www.imaginecommunications.com/services/technical support/ eCustomer Portal: http://support.imaginecommunications.com
© 2014 Imagine Communications Corp. Proprietary and Confidential
Preliminary—Contents are proprietary and confidential. Do not photocopy or distribute.
VSD / VSE6800
+
Standard Serial Digital Video
Distribution Amplifier
Installation and Operation
Manual
Edition C
March 2006
Preliminary—Contents are proprietary and confidential. Do not photocopy or distribute.
Contents
Preface
Revision History ............................................................................ vii
Writing Conventions ..................................................................... viii
Obtaining Documents ................................................................... viii
Unpacking/Shipping Information .......................................................... ix
Safety Standards and Compliances ..........................................................x
Safety Terms and Symbols ...............................................................x
Restriction on Hazardous Substances (RoHS) Directive ..................x
Waste from Electrical and Electronic Equipment
(WEEE) Directive ........................................................................... xi
Chapter 1: Introduction
Typical Broadcast and Production Applications ..............................2
Main Features ...................................................................................2
Front Module ....................................................................................3
Back Module .....................................................................................3
Chapter 2: Installation
+ Frame Power Ratings ..................................................8
Unpacking the Module .............................................................................9
Preparing for Installation ..................................................................9
Checking the Packing List ................................................................9
VSD/VSE6800
+ Installation and Operation Manual
v
Preliminary—Contents are proprietary and confidential. Do not photocopy or distribute.
Contents
+ Modules ..................................................................... 11
Required Frames and Back Module Connector Types .................. 11
+ Modules ............................................. 11
+ Modules ........................................... 11
Making Connections ...................................................................... 11
Chapter 3: Operation
Understanding Jumper Controls ............................................................ 14
Introducing Jumper Control Types ................................................ 14
Local Control ................................................................................. 14
Remote Control .............................................................................. 14
Understanding Parameter Types ........................................................... 16
Adjustable Parameters .................................................................... 16
Read-Only Parameters ................................................................... 16
Setting Locally-Accessible Parameters .......................................... 18
Setting Remotely-Controlled Parameters ....................................... 19
Changing Parameter Settings ................................................................ 20
Recalling Default Parameter Settings ............................................ 20
Reading the Software Version ....................................................... 20
Reading the Hardware Version ...................................................... 20
Module Status LED ........................................................................ 21
Other LED Descriptions ................................................................. 22
Chapter 4: Specifications
Power Consumption ............................................................................... 25
Index
vi VSD/VSE6800
+ Installation and Operation Manual
Preface
Manual Information
Purpose
This manual details features, installation and operational procedures, and specifications of the VSD / VSE6800
+ standard serial digital video distribution amplifier.
Audience
This manual is written for engineers, technicians and operators responsible for the installation, setup, and/or operation of the
VSD / VSE6800
+ standard serial digital video distribution amplifier.
Revision History
Table P-1. Manual Revision History
Edition
A
B
C
Date
May 2003
Revision History
Initial release
February 2005 Corrected the “Checking the Packing List” table; added information concerning maximum 6800
+ frame power ratings; corrected power specifications; added index
March 2006 Added RoHS and WEEE compliance information
VSD / VSE6800
+ Installation and Operation Manual
vii
Preface
Writing Conventions
To enhance your understanding, the authors of this manual have adhered to the following text conventions:
Table P-2. Manual Style and Writing Conventions
Term or
Convention
Description
Bold
Italics
Indicates dialog boxes, property sheets, fields, buttons, check boxes, list boxes, combo boxes, menus, submenus, windows, lists, and selection names.
Indicates email addresses, the names of books or publications, and the first instances of new terms and specialized words that need emphasis.
CAPS
Code
Note
Indicates a specific key on the keyboard, such as ENTER,
TAB, CTRL, ALT, or DELETE.
Indicates variables or command-line entries, such as a
DOS entry or something you type into a field.
> hyperlink
Indicates the direction of navigation through a hierarchy of menus and windows.
Indicates a jump to another location within the electronic document or elsewhere
Internet address Indicates a jump to a Web site or URL
Indicates important information that helps to avoid and troubleshoot problems.
Obtaining Documents
Documents can be viewed or downloaded from our Web site at www.broadcast.harris.com/leitch (go to support>documentation).
viii VSD / VSE6800
+ Installation and Operation Manual
Preface
Unpacking/Shipping Information
This product was carefully inspected, tested, and calibrated before shipment to ensure years of stable and trouble free service.
1. Check equipment for any visible damage that may have occurred during transit.
2. Confirm that you have received all items listed on the packing list.
3. Contact your dealer if any item on the packing list is missing.
4. Contact the carrier if any item is damaged.
5. Remove all packaging material from the product and its associated components before you install the unit.
Keep at least one set of original packaging, in the event that you need to return a product for servicing. If the original packaging is not available, you can supply your own packaging as long as it meets the following criteria:
• Withstands the weight of the product
• Holds the product rigid within the packaging
• Leaves at least two inches of space between the product and the container
• Protects the corners of the product
Ship products back to us for servicing prepaid and, if possible, in the original packaging material. If the product is still within the warranty period, we will return the product prepaid after servicing.
VSD / VSE6800
+ Installation and Operation Manual
ix
x
Preface
Safety Standards and Compliances
See the 6800
+ Safety Instructions and Standards Manual to find the safety standards and compliances for this 6800
+ series product. A safety manual is shipped with every FR6802
+ Frame Installation and
Operation Manual and can be downloaded from our Web site at www.broadcast.harris.com/leitch . Alternatively, contact your Customer
Service representative for a copy of this safety manual.
Safety Terms and Symbols
This product manual uses the following safety terms and symbols to identify certain conditions or practices. See the 6800
+ Safety
Instructions and Standards Manual for more information.
Table P-3. Safety Terms and Symbols
WARNING: Identifies conditions or practices that can result in personal injury or loss of life—high voltage is present.
Uninsulated dangerous voltage within the product’s enclosure may be sufficient to constitute a risk of electric shock to persons.
CAUTION: Identifies conditions or practices that can result in damage to the equipment or other property. Important operating and maintenance (servicing) instructions are included in the literature accompanying the product.
Restriction on Hazardous Substances (RoHS) Directive
Directive 2002/95/EC—commonly known as the European Union (EU)
Restriction on Hazardous Substances (RoHS)—sets limits on the use of certain substances found in electrical and electronic equipment. The intent of this legislation is to reduce the amount of hazardous chemicals that may leach out of landfill sites or otherwise contaminate the environment during end-of-life recycling. The Directive takes effect on
July 1, 2006, and it refers to the following hazardous substances:
• Lead (Pb)
• Mercury (Hg)
• Cadmium (Cd)
• Hexavalent Chromium (Cr-V1)
• Polybrominated Biphenyls (PBB)
• Polybrominated Diphenyl Ethers (PBDE)
VSD / VSE6800
+ Installation and Operation Manual
Preface
In accordance with this EU Directive, all products sold in the European
Union will be fully RoHS-compliant and “lead-free.” (See our Web site, www.broadcast.harris.com/leitch , for more information on dates and deadlines for compliance.) Spare parts supplied for the repair and upgrade of equipment sold before July 1, 2006 are exempt from the legislation. Equipment that complies with the EU directive will be
marked with a RoHS-compliant symbol, as shown in Figure P-1 .
Figure P-1. RoHS Compliance Symbol
Waste from Electrical and Electronic Equipment
(WEEE) Directive
The European Union (EU) Directive 2002/96/EC on Waste from
Electrical and Electronic Equipment (WEEE) deals with the collection, treatment, recovery, and recycling of electrical and electronic waste products. The objective of the WEEE Directive is to assign the responsibility for the disposal of associated hazardous waste to either the producers or users of these products. Effective August 13, 2005, producers or users will be required to recycle electrical and electronic equipment at end of its useful life, and must not dispose of the equipment in landfills or by using other unapproved methods. (Some
EU member states may have different deadlines.)
VSD / VSE6800
+ Installation and Operation Manual
xi
Preface
In accordance with this EU Directive, companies selling electric or electronic devices in the EU will affix labels indicating that such products must be properly recycled. (See our Web site, www.broadcast.harris.com/leitch , for more information on dates and deadlines for compliance.) Contact your local Sales representative for information on returning these products for recycling. equipment that complies with the EU directive will be marked with a WEEE-compliant
symbol, as shown in Figure P-2
.
Figure P-2. WEEE Compliance Symbol
xii VSD / VSE6800
+ Installation and Operation Manual
Preliminary—Contents are proprietary and confidential. Do not photocopy or distribute.
Chapter 1
Introduction
Overview
The VSD / VSE6800
+ is a serial digital video distribution amplifier. The
VSD / VSE6800
+ provides one SDI video input and eight SDI video outputs.
The following topics are described in this chapter:
•
“Product Description” on page 2
•
•
“Module Descriptions” on page 3
•
VSD / VSE6800
+ Installation and Operation Manual
1
2
Preliminary—Contents are proprietary and confidential. Do not photocopy or distribute.
Chapter 1: Introduction
Product Description
VSD6800
+ and VSE6800+ are serial digital video distribution amplifiers in the 6800+ family. These modules have one differential input and eight outputs.
• The VSD6800
+ is a serial digital video distribution amplifier with cable equalizing.
• The VSE6800
+ is a serial digital video distribution amplifier with cable equalizing and reclocking.
Both DAs feature high video performance, low cost, remote control, and diagnostic capability in Leitch's control system.
• The VSD6800
+ can distribute any 10 – 540Mb / s data within the amplitude limitation.
• The VSE6800
+ handles 143 Mb / s, 177 Mb / s, 270 Mb / s, 360
Mb / s, and 540Mb Mb / s serial digital video signals; and ASI signal
(4 outputs only).
You can set up, control, and monitor the VSD/VSE6800
+ either locally via card-edge jumper or remotely on a PC. For remote control, you can use either a serial RS-232 or optional ICE6800+ Ethernet connection.
Typical Broadcast and Production Applications
The VSD / VSE6800
+ distribution amplifiers can be used in broadcast, cable, production, educational, and auditorium applications where a low cost method of distributing serial digital video signals is required.
Main Features
VSD / VSE6800
+
• Input signal presence detect
• Automatic cable equalization
• Alarm output
VSE6800
+ Only
• Automatic / manual relock rate select at 143 / 177 / 270 / 360 / 540
Mb / s
• Reclocking status report
• Automatic / manual bypass
VSD / VSE6800
+ Installation and Operation Manual
Preliminary—Contents are proprietary and confidential. Do not photocopy or distribute.
Chapter 1: Introduction
Module Descriptions
Front Module
Figure 1-1 is a top view of a VSD/VSE6800
+ front module, and shows the general location of standard LEDs and jumper.
Figure 1-1. Typical VSD/VSE6800
+ Front Module
Back Module
FR6802
+ Frame Back Module
Figure 1-2 shows the double-width back module used by the
VSD/VSE6800
+ when installed in an FR6802+ frame.
Figure 1-2. Back Module for FR6802
+ Frame
VSD / VSE6800
+ Installation and Operation Manual
3
Preliminary—Contents are proprietary and confidential. Do not photocopy or distribute.
Chapter 1: Introduction
Signal Input / Output Connections for FR6802
+DM Frames
Note
Figure 1-3 shows the signal input / output connections used by the
VSD / VSE6800
+ when installed in an FR6802+DM frame.
Distribution amplifiers with unused inputs should have the input terminated. Not doing so may cause erroneous readings of a valid input signal that can be induced from adjacent slots.
Figure 1-3. Back Module for FR6802
+DM Frame
6800 / 7000 Series Frame Back Module (Overlay)
Note
Remote control for this 6800
+ module is not available if it is installed in a 6800 / 7000 series frame.
Figure 1-4 shows the double-width back module overlay used by the
VSD/VSE6800
+ when installed in a 6800 / 7000 series frame.
4
Figure 1-4. Back Module for 6800 / 7000 Series Frame
VSD / VSE6800
+ Installation and Operation Manual
Preliminary—Contents are proprietary and confidential. Do not photocopy or distribute.
Chapter 1: Introduction
Signal Flow
Figure 1-5. VSD/VSE6800
+ Signal Flow Diagram
VSD / VSE6800
+ Installation and Operation Manual
5
Preliminary—Contents are proprietary and confidential. Do not photocopy or distribute.
Chapter 1: Introduction
6 VSD / VSE6800
+ Installation and Operation Manual
Preliminary—Contents are proprietary and confidential. Do not photocopy or distribute.
Chapter 2
Installation
Overview
Caution
Before installing this product, read the 6800
+ Series Safety
Instructions and Standards
Manual shipped with every
FR6802
+ Frame Installation
and Operation Manual, or downloadable from our Web site at www.broadcast.harris.com/leitch . This safety manual contains important information about the safe installation and operation of
6800
+ series products.
Before installing this product,
see “Unpacking the Module” on page 9 .
This chapter describes the VSD / VSE6800
+ installation process, including the following topics:
•
“Unpacking the Module” on page 9
•
•
•
“Making Connections” on page 11
•
See the FR6802
+ Frame Installation and Operation Manual for information about installing and operating an FR6802
+ frame and its components.
See the 6800 / 7000 Series Frames and Power Supply Installation and
Operation Manual for information about installing and operating a
6800 / 7000 series frame.
VSD / VSE6800
+ Installation and Operation Manual
7
8
Preliminary—Contents are proprietary and confidential. Do not photocopy or distribute.
Chapter 2: Installation
Maximum 6800
+ Frame Power Ratings
Power consumption information is listed in
Chapter 4: Specifications” on page 25 .
Table 2-1 describes the maximum allowable power ratings for 6800
+ frames.Note the given maximums before installing any 6800
+ modules in your frame.
VSD / VSE6800
+ modules can be installed in FR6802+ frames and in
6800 / 7000 series frames.
Table 2-1. Maximum Power Ratings for 6800
+ Frames
6800
+ Frame Type
Power Supply
Type
AC
Max. Frame
Power
Dissipation
50 W FR6802
+DM
(frame without fans)
FR6802
+DMF
(frame with fans)
FR6802
+X
(frame without fans)
FR6802
+XF
(frame with fans)
FR6802
+DM48
(frame without fans)
FR6802
+DMF48
(frame with fans)
FR6802
+X48
(frame without fans)
FR6802
+XF48
(frame with fans)
AC
AC
AC
DC
DC
DC
DC
120 W
50 W
120 W
50 W
105 W
50 W
105 W
Number of
Usable Slots
10
10
20
20
10
10
20
20
Max. Power
Dissipation Per
Slot
5 W
12 W
2.5 W
6 W
5.0 W
10.5 W
2.5 W
5.25 W
VSD / VSE6800
+ Installation and Operation Manual
Preliminary—Contents are proprietary and confidential. Do not photocopy or distribute.
Chapter 2: Installation
Unpacking the Module
Preparing for Installation
Before you install the VSD / VSE6800
+, perform the following:
Note
• Check the equipment for any visible damage that may have occurred during transit.
Contact your Customer Service representative if parts are missing or damaged.
• Confirm receipt of all items on the packing list. See
Packing List” for more information.
• Remove the anti-static shipping pouch, if present, and all other packaging material.
• Retain the original packaging materials for possible re-use.
See
“Unpacking/Shipping Information” on page ix
for information about returning a product for servicing.
Checking the Packing List
Table 2-2. VSD / VSE6800
+ Packing List
Ordered Product
VSD / VSE6800
+
VSD / VSE6800
+S
VSD / VSE6800
+D
VSD / VSE6800
+SR
VSD / VSE6800
+DR
Content Description
• One VSD / VSE6800
+ front module
• One VSD / VSE6800
+ Installation and
Operation Manual
• One VSD / VSE6800
+ front module
• One standard single-slot back connector
• One VSD / VSE6800
+ Installation and
Operation Manual
• One VSD / VSE6800
+ front module
• One standard double-slot back connector
• One VSD / VSE6800
+ Installation and
Operation Manual
• One standard single-slot back connector
• One standard double-slot back connector
VSD / VSE6800
+ Installation and Operation Manual
9
Preliminary—Contents are proprietary and confidential. Do not photocopy or distribute.
Chapter 2: Installation
Setting Jumpers
Note
You need to configure modules for local or remote operation
before power-up. To change the configuration, first remove power from the module, reset the jumper, and then reapply power.
The VSE6800
+ module has one standard jumper. Follow this procedure to set the jumper for the proper signal:
1. Locate jumper set on the module (near the left top of the module).
Figure 2-1 shows the standard location of the jumper set.
Figure 2-1. Location of the Jumper Set
2. Place a jumper on the pin that corresponds to the reclocking mode that you want. See
10
Figure 2-2. Jumper Set Settings
VSD / VSE6800
+ Installation and Operation Manual
Preliminary—Contents are proprietary and confidential. Do not photocopy or distribute.
Chapter 2: Installation
Installing 6800
+ Modules
Required Frames and Back Module Connector Types
Note
VSD / VSE6800
+ modules with unused inputs should have the input terminated. Not doing so may cause erroneous readings of a valid input signal that can be induced from adjacent slots.
The VSD / VSE6800
+ modules have double-width back connectors that can be installed in an FR6802+X(F) or a 6800 / 7000 series frame.
• See the FR6802+ Frame Installation and Operation Manual for details on installing back connectors in an FR6802
+ frame.
• See the 6800 Series Frames and Power Supply Installation and
Operation Manual for details on installing back connectors in a
6800 / 7000 series frame.
Installing VSD / VSE6800
+ Modules
These modules require no specialized installation procedures.
• See the FR6802
+ Frame Installation and Operation Manual for information about installing and operating an FR6802
+ frame and its components.
• See the 6800 Series Frames and Power Supply Installation and
Operation Manual for information about installing and operating a
6800 / 7000 series frame.
Removing VSD / VSE6800
+ Modules
These modules require no specialized removal procedures.
• See the FR6802
+ Frame Installation and Operation Manual for information about removing components in an FR6802
+ frame.
• See the 6800 Series Frames and Power Supply Installation and
Operation Manual for information about removing components in a
6800 / 7000 series frame.
Making Connections
Once you have installed your VSD / VSE6800
+ modules, you can connect them to the appropriate input and outputs.
VSD / VSE6800
+ Installation and Operation Manual
11
Preliminary—Contents are proprietary and confidential. Do not photocopy or distribute.
Chapter 2: Installation
12 VSD / VSE6800
+ Installation and Operation Manual
Preliminary—Contents are proprietary and confidential. Do not photocopy or distribute.
Chapter 3
Operation
Overview
This chapter describes how to operate the VSD / VSE6800
+ using card-edge controls only. See the following Leitch documents for information on how to operate this product remotely:
•
+Pilot Lite User Manual for serial control interface
• CCS™ Navigator™, Pilot™, CoPilot™, or RCP-CCS-1U Remote
Control Panel Installation and Operation Manual for Ethernet control interface
The following topics are discussed in this chapter:
•
“Changing Parameter Settings” on page 20
•
•
•
“Setting Parameters” on page 18
•
“Understanding Jumper Controls” on page 14
•
“Understanding Parameter Types” on page 16
VSD / VSE6800
+ Installation and Operation Manual
13
Preliminary—Contents are proprietary and confidential. Do not photocopy or distribute.
Chapter 3: Operation
Understanding Jumper Controls
Introducing Jumper Control Types
Note
You can use the jumper on the front edge of the VSE6800
+ to select either local control or remote control reclock setting operation mode.
illustrates the location of this jumper.
We recommend that you use the available 6800
+ software control options (serial / local or
Ethernet / remote) to aid in viewing, setting, and confirming parameter values.
Local Control
Note
In the local control reclock setting operation mode, all of the settings’ data status information appears on the
+Pilot Lite control screen; however, you cannot change any setting in this mode via
+Pilot Lite. To control the reclocking setting mode via
+Pilot Lite, set the jumper to the remote control reclock setting operation mode.
The local control is used to select one of three reclocking setting modes by a jumper at the board edge: automatic, manual, and bypass.
• The automatic reclocking setting mode automatically reclocks the input signal. The RCLK LED is green and the corresponding rate indicator LED (yellow) is on when this reclock is successful.
If this reclocking attempt fails, the RCLK LED will be red and the signal bypasses the reclocker and is present at outputs.
• The manual reclocking setting mode allows you to select at which
rate the input signal attempts to reclock. (See Table 3-1 on page 15
for instructions on setting up the operation for reclocking rates.)
• The bypass mode allows you to force the input data to take the bypass path, whether it is locked or not.
Remote Control
Note
To control the reclocking setting mode manually, set the jumper to the local control reclock setting operation mode.
When the jumper is set to the “remote” position, the reclocker setting is handled by
+Pilot Lite only. You may select the three setting modes
(automatic, manual, and bypass) remotely via
+Pilot Lite.
14 VSD / VSE6800
+ Installation and Operation Manual
Preliminary—Contents are proprietary and confidential. Do not photocopy or distribute.
Chapter 3: Operation
Table 3-1. Reclocking Mode Setting
See
Figure 2-2 on page 10 for a picture of the jumper set settings
Input Signal
143 Mb / s
177 Mb / s
270 Mb / s
360 Mb / s
540 Mb / s
Operation Setup
Set the jumper on the pin that allows the reclocker to handle 143 Mb / s data only
• If the reclocking is successful, the RCLK LED will be green and the 143 Mb / s
LED will be yellow
• If the reclocking is not successful, the RCLK LED will be red, the 143 Mb / s
LED will be off, and un-reclocked data will be present at output
Set the jumper on the pin that allows the reclocker to handle 177 Mb / s data only
• If the reclocking is successful, the RCLK LED will be green and the 177 Mb / s
LED will be yellow
• If the reclocking is not successful, the RCLK LED will be red, the 177 Mb / s
LED will be off, and un-reclocked data will be present at output
Set the jumper on the pin that allows the reclocker to handle 270 Mb / s data only
• If the reclocking is successful, the RCLK LED will be green and the 270 Mb / s
LED will be yellow
• If the reclocking is not successful, the RCLK LED will be red, the 270 Mb / s
LED will be off, and un-reclocked data will be present at output
Set the jumper on the pin that allows the reclocker to handle 360 Mb / s data only
• If the reclocking is successful, the RCLK LED will be green and the 360 Mb / s
LED will be yellow
• If the reclocking is not successful, the RCLK LED will be red, the 360 Mb / s
LED will be off, and un-reclocked data will be present at output
Set the jumper on the pin that allows the reclocker to handle 540 Mb / s data only
• If the reclocking is successful, the RCLK LED will be green and the 540 Mb / s
LED will be yellow
• If the reclocking is not successful, the RCLK LED will be red, the 540 Mb / s
LED will be off, and un-reclocked data will be present at output
VSD / VSE6800
+ Installation and Operation Manual
15
Preliminary—Contents are proprietary and confidential. Do not photocopy or distribute.
Chapter 3: Operation
Understanding Parameter Types
Most VSD / VSE6800
+ parameters are adjustable, and can be set using
either card-edge controls (see “Introducing Jumper Control Types” on page 14
) or a software application. However, there are some parameters that are considered “read-only” and cannot be changed. Indicated by the abbreviation “[RO],” these parameters provide status and feedback information only.
Adjustable Parameters
Two types of adjustable parameters can be changed using the card-edge controls:
• Numerical parameters—which require you to select a value within a numerical range
• Selectable parameters—which require you to select a specific option
Both numerical and selectable parameter changes are immediate.
Use the available 6800
+ software controls (serial / local or
Ethernet / remote network) to view and monitor parameter selections.
Read-Only Parameters
Many of the read-only parameters are also represented by LEDs on the front of the module’s card edge. See
location of these LEDs.
16 VSD / VSE6800
+ Installation and Operation Manual
Preliminary—Contents are proprietary and confidential. Do not photocopy or distribute.
Chapter 3: Operation
Operating Notes
When setting the control parameters on the VSD / VSE6800
+, observe the following:
• When you change a parameter, the effect is immediate. However, the module requires up to 20 seconds to save the latest change.
After 20 seconds, the new settings are saved and will be restored if the module loses power and must be restarted.
When setting the control parameters on the VSE6800
+, observe the following:
• When the module is set to remote control, the reclocking mode is controlled by the CCS control software application. When the module powers up with remote selected, the reclocking mode is set to the last known value.
• When the module is set to local control, the reclocking mode is controlled by adjusting the card-edge jumper to the appropriate setting. Reclocking mode selections are reflected in the CCS control software application. Any remote attempts to adjust the reclocking mode will have no effect.
• If a card-edge jumper is not installed the reclocking mode is set to
Auto.
When setting the control parameters on the VSD6800
+, observe the following:
• The module has no user settable controls. As in the VSE6800
+, status information is reflected on the card-edge LEDS and in the
CCS control software application.
VSD / VSE6800
+ Installation and Operation Manual
17
Preliminary—Contents are proprietary and confidential. Do not photocopy or distribute.
Chapter 3: Operation
Setting Parameters
Setting Locally-Accessible Parameters
Table 3-2 describes VSD / VSE6800
+ parameters that are accessible
jumper.
Table 3-2. Locally-Accessible Parameters
Parameter
Name
Module status
Range Description
Signal presence
Re-clockable
Reclocking
Mode setting
• Red
• Green
• Off
• Red, blinking
• Alternating
• Red
• Green
• Red
• Green
• Auto
• 143
• 177
• 270
• 360
• 540
• Bypass
• Remote
Alarm condition exists
Module is operating properly
Module is not operational
Module not operational; hardware fault
Module configuration ongoing
Signal absent
Signal present
Not reclockable
Reclockable
Automatically select reclock mode
Only 143 Mb / s can be locked
Only 177 Mb / s can be locked
Only 270 Mb / s can be locked
Only 360 Mb / s can be locked
Only 540 Mb / s can be locked
Allow data to bypass reclocker
Let CCS select the control mode
18 VSD / VSE6800
+ Installation and Operation Manual
Preliminary—Contents are proprietary and confidential. Do not photocopy or distribute.
Chapter 3: Operation
Setting Remotely-Controlled Parameters
Table 3-3 describes VSD / VSE6800
+ parameters that are accessible remotely. See your CCS control software application manual or online help for more information on setting and monitoring the following parameters remotely.
Table 3-3. Remotely Controlled Parameters
Parameter Name
Locked Data Rate
[RO]
Signal Present
[RO]
Re-Clocking Mode
Range
• None
• 143 Mb / s
• 177 Mb / s
• 270 Mb / s
• 360 Mb / s
• 540 Mb / s
• No
• Yes
• Auto
• 143 Mb / s
• 177 Mb / s
• 270 Mb / s
• 360 Mb / s
• 540 Mb / s
• Bypass
Description
Returns the locking status of the reclocker (not available on the
VSD6800
+)
Returns the presence of the input signal
Sets the module working mode (not available on the
VSD6800
+)
VSD / VSE6800
+ Installation and Operation Manual
19
Preliminary—Contents are proprietary and confidential. Do not photocopy or distribute.
Chapter 3: Operation
Changing Parameter Settings
You can change VSD / VSE6800
+ parameter settings locally with the card-edge jumper or remotely by selecting the Reclocking Mode parameter setting.
Recalling Default Parameter Settings
You cannot recall default parameter settings for the VSD / VSE6800
+.
Reading the Software Version
The current software version of your VSD / VSE6800
+ module can be viewed using Pilot (via Ethernet control). See your CCS Pilot User
Manual or Online Help for information on viewing software versions.
Reading the Hardware Version
The current hardware revision of your VSD / VSE6800
+ module can be viewed using Pilot (via Ethernet control). See your CCS Pilot User
Manual or Online Help for information on viewing hardware identifiers.
20 VSD / VSE6800
+ Installation and Operation Manual
Preliminary—Contents are proprietary and confidential. Do not photocopy or distribute.
Chapter 3: Operation
LEDs and Alarms
Module Status LED
The VSD / VSE6800
+ module has a module status indicator LED that reports the state of the module. See Figure 1-1 for the location of this
for a definition of the LED colors.
Table 3-4. Module Status LED Descriptions
LED Color Sequence
Off
Green
Red
Amber
Meaning
There is no power to the module; the module is not operational
There is power to the module; the module is operating properly
There is an alarm condition
The module is undergoing configuration
Alarms
Alarms are usually logged and monitored within the available 6800
+ software control applications (for example,
+Pilot Lite or Pilot). See the appropriate software control user manual or online help for more information.
VSD / VSE6800
+ Installation and Operation Manual
21
Preliminary—Contents are proprietary and confidential. Do not photocopy or distribute.
Chapter 3: Operation
Other LED Descriptions
Each 6800
+ module has a number of LEDs assigned to indicated varying states / functions. For VSD / VSE6800
+ modules, these
functions are listed in Table 3-5 . See
Figure 1-1 for the location of these
LEDs.
Table 3-5. Module-Specific Status LEDs
LED Name
Signal
Color
Green
Rclk
1
Red
Green
Red
143
1
177
1
270
1
360
1
Green
Green
Green
Green
540
1
Green
1
Not functional in VSD6800
+
Description (When Lit)
Signal present
Signal not present
Data rate locked
Data rate not locked
143 Mb / s data rate locked
177 Mb / s data rate locked
270 Mb / s data rate locked
360 Mb / s data rate locked
540 Mb / s data rate locked
22 VSD / VSE6800
+ Installation and Operation Manual
Preliminary—Contents are proprietary and confidential. Do not photocopy or distribute.
Chapter 4
Specifications
Overview
The following specification tables appear in this chapter:
•
•
•
•
“Power Consumption” on page 25
•
•
Specifications and designs are subject to change without notice.
VSD / VSE6800
+ Installation and Operation Manual
23
Preliminary—Contents are proprietary and confidential. Do not photocopy or distribute.
Chapter 4: Specifications
Inputs
Note
VSD / VSE6800
+ modules with unused inputs should have the input terminated. Not doing so may cause erroneous readings of a valid input signal that can be induced from adjacent slots.
Table 4-1. VSD / VSE6800
+ Input Specifications
Item
Signal type
Connector
Impedance
Return loss
Maximum signal
Cable equalization
SDI 270 Mb / s
Specification
SDI, ASI
BNC (IEC169-8)
75
Ω
>18 dB 5 MHz to 540 MHz
≥ 0.88 V
0 – 984 ft (0 – 300 m) Belden 1694A or equivalent
Outputs
Table 4-2. VSD / VSE6800
+ Output Specifications
Item
Number of outputs
SDI
ASI
Signal type
Connector
Impedance
Return loss
Signal amplitude
DC offset
Rise and fall time
Overshoot
Specification
8
4
SDI, ASI
BNC (IEC169-8)
75
Ω
>18 dB 5 MHz to 540 MHz
800 mV ± 10%
0.0 V ± 0.5 V
400 to 700 pS
<10%
24 VSD / VSE6800
+ Installation and Operation Manual
Preliminary—Contents are proprietary and confidential. Do not photocopy or distribute.
Chapter 4: Specifications
Performance
Power Consumption
Table 4-4. Power Consumption Specifications
Item
VSD6800
+
VSE6800
+
Specification
2.5 W
3.5 W
Temperature
Table 4-3. VSD / VSE6800
+ Performance Specifications
Item
Jitter
Propagation
VSD6800
+
VSE6800
+
Specification
< 0.2 UI
< 12.0 ns
< 12.5 ns
Table 4-5. Temperature Specifications
Item
Operating temperature
Performance temperature
Specification
32° to 122° F (0° – 50° C)
41° to 104° F (5° – 40° C)
Start-Up Time
Start-up time for VSD / VSE6800
+ modules is approximately 10 seconds.
VSD / VSE6800
+ Installation and Operation Manual
25
Preliminary—Contents are proprietary and confidential. Do not photocopy or distribute.
Chapter 4: Specifications
26 VSD / VSE6800
+ Installation and Operation Manual
Index
Keywords
A-G
Adjustable parameters
Applications
Back connectors. See Back modules
Back modules
Changing parameter settings 20
Controls control types
understanding controls
Descriptions
LEDs
module descriptions back modules
front modules
Directives
Restriction on Hazardous Substances x
Waste from Electrical and Electronic Equipment
Features
Front modules
H-L
Input specifications
back modules
installing modules
power ratings
preparing modules
removing modules
required frames
unpacking modules
applications 2 main features 2
module descriptions back modules
front module
signal flow diagram
Jumpers controls control types
remote control
14 understanding jumper controls
LEDs
module specific
module status
Locally-accessible parameters
M-R
VSD / VSE6800
+ Installation and Operation Manual
27
Index
Modules back modules
front modules
installing modules
LEDs
preparing modules
removing modules
unpacking modules
alarms
jumper control types
LEDs
local jumper controls
operating notes
parameters changing settings
locally-accessible parameters 18
parameter types
remotely-controlled parameters
setting parameters
reading hardware versions
remote jumper controls
14 understanding jumper controls 14–15
Output specifications
Parameters
changing settings
parameter types
setting parameters
Performance specifications
Performance temperature
Power consumption specifications
Power ratings
Preparing for installation
Product description
Reclocking mode setting
Remote control jumpers
Remotely-controlled parameters
Removing modules
Restriction on Hazardous Substances (RoHS) directive
S-Z
Safety compliances
RoHS directive
standards
symbols
WEEE directive
Setting jumpers
Shipping information
Signal flow diagram
Software versions, reading
Specifications input
output
performance
power consumption
start-up time
temperature
Start-up time
Temperature specifications
Waste from Electrical and Electronic Equipment
(WEEE) directive
28 VSD / VSE6800
+ Installation and Operation Manual
다운로드
광고