Below you will find brief product information for Ada Suite-16. It offers robust capabilities, flexibility, and ease of use, making it one of the most popular multi-room audio and video distribution systems on the market. With its modular design, you can customize the system to fit your specific needs and budget.
Advertisement
Advertisement
R
EVISED
A
PRIL ‘02
System Design
&
Technical Documentation
602-610 Mamaroneck Avenue, White Plains, NY, 10605, www.ada-usa.com, 1-800-HD-AUDIO, Fax (914) 946-9620
Contents
Suite 16 Modules ........................................................................ 2
A-16 Audio Input Module ............................................................ 3
Paging Features .......................................................................... 8
P-16 Preamplifier Module ............................................................ 9
Power Amplifier Options ........................................................... 12
Home Theater (or Recording) Set Up ......................................... 16
Amp Trigger Jumping on 9-Pin D Connectors ........................... 17
V-16 Video Switching Module ................................................... 18
AVP-16 Baud Rate, Zone, & Paging Settings .............................. 20
AVP-16 Configuration Options .................................................. 22
Matrix Switching - S-Video, Component, or RGBHV .................... 23
AVP-16 Slave-Unit Configuration Options .................................. 25
AVP-16 Slave-Unit Setup ........................................................... 26
AVP-16 Main & Slave Unit Power-On Setup ................................ 27
AVP-16 ADA Bus & Control Wiring ............................................ 28
Damaged Wiring Options .......................................................... 30
CAT-Link and ADA Bus Wiring ................................................... 30
IR Repeating ............................................................................. 30
IR Control of the Suite 16 ......................................................... 31
RF Control ................................................................................ 32
MC-6000 Keypad with Video, WH-6000, & TV-6000................... 34
CMB-1 Clock Module ................................................................. 36
MC-5011 Keypad Setup ............................................................. 37
MC-5000 Keypad LED Setup ...................................................... 38
MC-5000 Keypad Manual Setup................................................. 39
MC-5000 Installer Setup ............................................................ 41
RS-232 Connections for PC’s & Control Systems.......................... 48
Keypad Uploader Program (MC-5KS Uploader) .......................... 49
Suite 16 Testing & Program ....................................................... 54
Suite 16 Serial Protocol V1.4 Explanation ................................ 64
Suite 16 Video Card V1.1 or V1.2 Protocal Explanation ............. 81
Suite 16 ASCII Codes ................................................................. 84
Appendix A - MC-5000 Setup Flow Charts ................................. 87
Appendix B - System Specifications ........................................... 94
Appendix C - 9 Pin D Connector Information ............................. 95
All specifications subject to change without prior notice.
©2002 Audio Design Associates, Inc. All rights reserved.
- 1 -
Suite 16 Modules
Suite 16 is appropriately named as it is a system that is built using a suite of modules and components. These modules and other components allow extraordinary flexibility in the design of a distributed entertainment system. This section will focus on the three modules that are inserted into the Suite 16 Multi-Room (MR) Controller Chassis, the AVP-16.
AVP-16 Multi-Room (MR) Controller Chassis
The AVP-16 is a chassis that can hold up to three Suite 16 Modules. Several AVP-16s can be used in a single system. The AVP-16 features a front panel power/reset switch, front panel
RS-232 9-Pin “D” style connector, and a removable plexi-glass window. This window will permit access to Suite 16 Module adjustment controls as well as permitting Suite 16 Module
Status LEDs to be seen during normal operation.
POWER
AVP-16
RS-232
L
R
L
R
1
2
1
1
3
4
2
2
5
6
3
3
8
4
4
10
5
5
7
VIDEO INPUTS
9 11
12
6
6
13
14
7
7
15
16
8
8
A-16
P-16
1
V16
2
EXPANSION PORTS
9
9
3
4
10
10
5
6
11
11
7
8
12
12
9
10
13
13
11
12
14
14
13
14
15
15
15
16
16 In 1-8
Input Triggers
In 6/14
In 5/13
In 7/15
In 8/16
Gnd
A-16 • Audio Input Module
Balanced
Audio Page
Input (600
Ω)
1
Com
2
(+)
3
(-)
Trigger
5-24V
AC•DC
4
(+)
5
(-)
1 Gnd
2 Fdbk
4 +V
ADA Bus®
230V
3 Cntrl
16
In 9-16
+12VDC Outputs
Paging Input/Trigger
Zones 1- 6 & 7-12
Zones 1-6
In 6/12 TO PTM-1225/1260
In 4/10
In 3/9
In 1/7
In 2/8
P-16 • Preamplifier Module
Zones 13-16
+12VDC Output
Gnd
(-)
13
(+)
14
(+)
15
(+)
16
(+)
115V
115 V
1/2 ASB
115V~
1/4 ASB
230V~
Out 1-8
Output Triggers
Out 6/14
Out 5/13
Out 7/15 Out 8/16
Gnd
V-16 • Video I/O Module
Programmed Video
Input Triggers
5-24V AC•DC
Gnd
(-)
1
(+)
2
(+)
3
(+)
4
(+)
Switch
AC
(10A)
Out 9-16
+12VDC Outputs
Input Triggers
Main
AC
Input
Network Control I/O
WARNING! Risk Of Hazardous Energy!
Make Proper Connections.
AVERTISSEMENT! Energie Electrique
Dangereuse!
Faire Des Connexions Propres
Pour L'Hautparleur.
Voir La Notice De Fonctionnement.
CAUTION: Disconnect Supply
Cord Before Servicing.
ATTENTION: Debrancher
Avant Le Depannage.
115V~/60Hz • 230V~/50Hz
500 WATTS MAX
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
ATTENTION!
RISQUE DE CHOC ELECTRIQUE.
NE PAS OUVRIR
MADE IN U.S.A.
AVP-16 MR Controller
The Suite 16 is completely modular including the Power Supply and Control I/O section. The
Power-Control Module slides in from the back of the AVP-16 chassis and can be removed in the event service is required.
The back of the AVP-16 also features two Expansion ribbon cable connections. These are only used when multiple AVP-16s are employed on a single project.
- 2 -
A-16 Audio Input Module
Only one A-16 Audio Input Module is used per Suite 16 System.
L
R
1 2 3 4 5 6 7 8
A-16
9 10 11 12 13 14 15 16 In 1-8
Input Triggers
In 6/14
In 5/13
In 4/12
In 3/11
In 7/15
In 8/16
Gnd
In 1/9
In 2/10
A-16 • Audio Input Module
Balanced
Audio Page
Input (600 Ω)
1 2 3
Com (+) (-)
Trigger
5-24V
AC•DC
4 5
(+) (-)
In 9-16
+12VDC Outputs
Paging Input/Trigger
Audio Inputs
The A-16 features 16 stereo RCA jacks which are the sixteen audio inputs to the system.
Input Level Trim Control
By and large most audio source components put out audio signal levels that are close to each other. However, some sources run significantly louder while other sources are significantly softer. This becomes an issue as you change inputs in a room, as volume levels can vary between selected components, even though the room’s volume control has not been altered.
To compensate for varying output levels between source components, the Suite 16 System permits a different input level for each of the sixteen audio inputs. This feature is set in software.
In 1-8
Input Triggers
Input Tracking Low Voltage Triggers
The A-16 also features two 9-pin “D” style connectors (non-RS-
232). The top connector includes a common ground pin and then eight other pins corresponding to inputs 1-8. The bottom connector also features a common ground pin and eight connectors which correspond with inputs 9-16. When an input is selected, its corresponding pin produces a 12VDC output. This trigger can be used to activate a source component function.
In 6/14
In 5/13
In 4/12
In 3/11
In 7/15
In 8/16
Gnd
In 1/9
In 2/10
A-16
Balan
Audio
Input (
1
Com
2
(+
In 9-16
+12VDC Outputs
Paging
120-240 VAC
50-60 Hz
Set Shunting Pins To Engage AC With Zone Or Source Numbers 1-8
1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8
TO 9 PIN "D"
DELTA-88
1 2 3 4
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
ATTENTION!
RISQUE DE CHOC ELECTRIQUE.
NE PAS OUVRIR
MADE IN U.S.A.
ACC-48
QUAD AC CONTROLLER
1.
2.
1000 WATTS
MAX TOTAL
Delta-88 9 Pin "D" programmed for source AC control. - Set one shunting pin per AC outlet according to source inputs. Set 3 pins for MT-3000.
Delta-88 9 Pin "D" programmed for zone AC control. - Set one shunting pen per AC outlet according to zone numbers. Set all shunting pins on one AC Outlet for All-On source AC control when not using an ACC-3000.
When using ADA’s ACC-48 Source Component AC Switcher, these two connectors can be attached to up to two ACC-48s each. This will provide AC component switching (based on activity) for as many as sixteen source components. As with most every ADA System, Suite 16 permits the AC to be removed from source components when they are not being used. This is intended to preserve the life of the device as even standby-power is removed when the component is not in use.
This may not be an option for devices with built-in clocks or devices that require AC at all times.
Please note, that each switched outlet on the ACC-48 is limited to 2.5 amps.
- 3 -
RS-232
Pins
2=Tx
3=Rx
5=Com
IR Repeating Only
40KHz IR Repeat
Frequency Repeater
IR - Serial
Serial
Data Only
1 2 3 4
Gnd Rx Tx +15V
ADA Bus®
ADA/232
Source Ports: 1 2 3 4 5 6 7 8
Data/Carrier
Off Norm Invert
Repeater
IR - Serial
Serial
Data Only
IR Flasher=Remove Jumper
Serial Direct=Insert Jumper Off Norm Invert
RS-232
ADA Bus
Repeater
IR - Serial
Serial
Data Only
Off Norm Invert
Repeater
IR - Serial
Serial
Data Only
1
2
3
Off Norm Invert
Repeater
IR - Serial
Serial
Data Only
4
5
PGM DEL
CON ERR
IRL-5000
Source Controller
Power On/Off IR Macro
Connect To Mainframe
Source DC Triggers &
ACC-48 AC Controllers
Off Norm Invert
Repeater
IR - Serial
Serial
Data Only
Off Norm Invert
Repeater
IR - Serial
Serial
Data Only
6
7
Off Norm Invert
Repeater
IR - Serial
Serial
Data Only
Off Norm Invert 8
The two low voltage triggers can also be used to engage an “On” and an “Off” IR command when using
ADA’s IRL-5000 to control source components.
The IRL-5000 is an advanced version of ADA’s IRL-
3000 Infrared Learner and uses the same PC software program to capture, test, layout, and label IR commands from standard source components. While the IRL-5000 is used on Suite 16 Systems when employing ADA keypads (so that the keypads transport function buttons can control the source components), the IRL-5000 can also be controlled serially making it an ideal component to add to a Suite 16 even if no
ADA keypads are being used. A single IRL-5000 can operate as many as eight source components. Two
IRL-5000’s can be used to control sixteen components when set to different addresses. The IRL-5000 has nine address settings.
The IRL-5000 features two 9-pin “D” connectors. The connector on the upper left side is used for programming and is connected to a PC. The connector at the bottom of the IRL-5000 is wired in parallel with the ACC-48(s). By using this feature of the IRL-5000, one can initiate an
IR signal or sequence (macro) when a source is first selected and also initiate an IR signal or sequence when that source is no longer being used. Since the IRL-5000 permits the use of delays, you can use both the ACC-48 and IRL-5000 together such that as a source is selected, it gets AC from the ACC-48 and then is issued a command (i.e. play). Another option for DSS receivers would involve programming the OFF function with a macro to reset the
DSS receiver to the favorite music channel. Thus, every time the DSS is no longer being used on the system, the IRL-5000 resets it to this station. When it is again selected, the favorite channel is already tuned in. This permits one button operation while completely removing AC from the component when it is no longer being used.
Naturally, one can simply use the IRL-5000 without employing ACC-48s. When using an ADA
Trinity Tuner, ADA recommends using at least one IRL-5000.
The diagrams on the next two pages show an IRL-5000 employed with two ACC-48s. The diagram on page 6 details the complete sixteen source system with two IRL-5000s and four
ACC-48’s.
LVI-3800 Low Voltage Relay
The LVI-3800 is used when controlling source components that are not capable of control via either serial or IR control interfaces.
Older sources or for example, slide projectors fall into this category. The LVI-3800 features eight relays which close momentarily when transport buttons are pressed on the MC-5000, MC-
3000, and MC-3800 keypads. The LVI-3800 is an ADA Bus device and connects to an open ADA Bus jack on any wire harness.
NORM. CLOSED NORM. OPEN Carefully remove and insert relays for changing from the Normally Open to the Normally Closed position.
+12V
+5V
-
RELAY 1
SW 2
R1
RELAY 2
ON
ADA BUS™
R2
RELAY 3
8 7 6 5 4 3 2 1
R3
R4
R5
R6
R7
R8
RELAY 4
RELAY 5
RELAY 6
RELAY 7
RELAY 8
2
1
4
3
LVI-3800
LOW VOLTAGE RELAY
SW 1
NORM
ON
8
7
6
5
4
3
2
1
RX/TX
SET
REV
- 4 -
120-240 VAC
50-60 Hz
Set Shunting Pins To Engage AC With Zone Or Source Numbers 1-8
1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8
1 2 3 4
TO 9 PIN "D"
DELTA-88
TO AC
OUTLET
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
ATTENTION!
RISQUE DE CHOC ELECTRIQUE.
NE PAS OUVRIR
MADE IN U.S.A.
ACC-48
QUAD AC CONTROLLER
1.
2.
1000 WATTS
MAX TOTAL
Delta-88 9 Pin "D" programmed for source AC control. - Set one shunting pin per AC outlet according to source inputs. Set 3 pins for MT-3000.
Delta-88 9 Pin "D" programmed for zone AC control. - Set one shunting pen per AC outlet according to zone numbers. Set all shunting pins on one AC Outlet for All-On source AC control when not using an ACC-3000.
ACC-48 OUTLET 3 (PHONOGRAPH)
& OUTLET 4 (PHONO-PREAMP)
SET TO TURN ON TOGETHER
120-240 VAC
50-60 Hz
Set Shunting Pins To Engage AC With Zone Or Source Numbers 1-8
1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8
TO 9 PIN "D"
DELTA-88
1 2 3 4
TO AC
OUTLET
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
ATTENTION!
RISQUE DE CHOC ELECTRIQUE.
NE PAS OUVRIR
MADE IN U.S.A.
ACC-48
QUAD AC CONTROLLER
1.
2.
1000 WATTS
MAX TOTAL
Delta-88 9 Pin "D" programmed for source AC control. - Set one shunting pin per AC outlet according to source inputs. Set 3 pins for MT-3000.
Delta-88 9 Pin "D" programmed for zone AC control. - Set one shunting pen per AC outlet according to zone numbers. Set all shunting pins on one AC Outlet for All-On source AC control when not using an ACC-3000.
9 PIN RIBBON
CABLE WITH
9 PIN "D"
CONNECTOR
FOR SOURCE
AC TRIGGERS
12VAC
X-FORMER
FOR
PP-1200
PHONO
PREAMP
IRL-5000
RS-232
Pins
2=Tx
5=Com
IR Repeating Only
40KHz IR Repeat
Frequency Serial
Data Only
1 2 3 4
Gnd Rx Tx +15V
ADA Bus®
Data/Carrier
ADA/232
Source Ports: 1 2 3 4 5 6 7 8
IR Flasher=Remove Jumper
Serial Direct=Insert Jumper
Norm Invert
Off
Repeater
IR - Serial
Serial
Data Only
Off Norm Invert
RS-232
ADA Bus
Repeater
IR - Serial
Serial
Data Only
Off Norm Invert
Repeater
IR - Serial
Serial
Data Only
1
2
3
IRL-5000
Source Controller
Off Norm Invert
Repeater
IR - Serial
Serial
Data Only
Norm Invert
Off
Repeater
IR - Serial
Serial
Data Only
4
5
PGM DEL
CON ERR
Power On/Off IR Macro
Connect To Mainframe
Source DC Triggers &
ACC-48 AC Controllers
Off Norm Invert
Repeater
IR - Serial
6
7
Off Norm Invert
Repeater
IR - Serial
Serial
Data Only
Off Norm Invert
8
FM 1
FM 2
CD 1
CD 2
CASSETTE
VCR
DVD
GROUND WIRE
AUDIO CABLE
GND
L R
INPUT
PP-1200
PHONO
PREAMP
Ground Post
PP-1200
Phono Preamplifier
L
Gain L
L
12VAC Power
R
Phono Input
R
Gain R
Phono Preamp Output
GAIN
OUTPUT
L R
GAIN
120VAC
DC
POWER
L
1
R
2 3
AUDIO CABLE
4
PHONOGRAPH
5 6 7
AC
LINE
CORD
8 9
A-16
10 11 12 13 14 15 16 In 1-8
Input Triggers
In 5/13
In 3/11
In 7/15
A-16 • Audio Input Module
Balanced
Audio Page
Input (600 )
1
Com
2
(+)
3
(-)
Trigger
5-24V
AC•DC
4
(+)
5
(-)
In 9-16
+12VDC Outputs
Paging Input/Trigger
PP-1200 Phono-Preamplifer
If you still enjoy playing records, there is no reason not to be able to access them through your whole-house Suite 16 System. Most turntable use a moving-magnet cartridge which requires special preamplification. The PP-1200 Phono Preamplifier provides this preamplification and permits the connection of a phonograph to the Suite 16.
- 5 -
120-240 VAC
50-60 Hz
Set Shunting Pins To Engage AC With Zone Or Source Numbers 1-8
1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8
TO 9 PIN "D"
DELTA-88
1 2 3 4
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
ATTENTION!
MADE IN U.S.A.
ACC-48
QUAD AC CONTROLLER
1.
2.
1000 WATTS
MAX TOTAL
Delta-88 9 Pin "D" programmed for source AC control. - Set one shunting pin per AC outlet according to source inputs. Set 3 pins for MT-3000.
Delta-88 9 Pin "D" programmed for zone AC control. - Set one shunting pen per AC outlet according to zone numbers. Set all shunting pins on one AC Outlet for All-On source AC control when not using an ACC-3000.
120-240 VAC
50-60 Hz
Set Shunting Pins To Engage AC With Zone Or Source Numbers 1-8
1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8
TO 9 PIN "D"
DELTA-88
1 2 3 4
IRL-5000
Address 1
RS-232
Pins
2=Tx
3=Rx
5=Com
IR Repeating Only
40KHz IR Repeat
Frequency Repeater
IR - Serial
Serial
Data Only
1 2 3 4
Gnd Rx Tx +15V
ADA Bus®
ADA/232
Source Ports: 1 2 3 4 5 6 7 8
Data/Carrier
Off
Repeater
IR - Serial
Norm Invert
Serial
Data Only
IR Flasher=Remove Jumper
Serial Direct=Insert Jumper
Off Norm Invert
RS-232
ADA Bus
Repeater
IR - Serial
Serial
Data Only
Off Norm Invert
Repeater
IR - Serial
Serial
Data Only
1
2
3
Off Norm Invert
Repeater
IR - Serial
Serial
Data Only
4
5
PGM DEL
IRL-5000
Source Controller
Power On/Off IR Macro
Connect To Mainframe
Source DC Triggers &
ACC-48 AC Controllers
Off
Norm Invert
Repeater
IR - Serial
Serial
Data Only
Off Norm Invert
Repeater
IR - Serial
Serial
Data Only
6
7
CON ERR
Off
Repeater
IR - Serial
Norm Invert
Serial
Data Only
Off Norm Invert
8
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
ATTENTION!
RISQUE DE CHOC ELECTRIQUE.
NE PAS OUVRIR
MADE IN U.S.A.
ACC-48
QUAD AC CONTROLLER
1.
2.
1000 WATTS
MAX TOTAL
Delta-88 9 Pin "D" programmed for source AC control. - Set one shunting pin per AC outlet according to source inputs. Set 3 pins for MT-3000.
Delta-88 9 Pin "D" programmed for zone AC control. - Set one shunting pen per AC outlet according to zone numbers. Set all shunting pins on one AC Outlet for All-On source AC control when not using an ACC-3000.
Sources 1-8
AC Switching
& IR Control
L
R
L
R
1
2
1
1
3
4
2
2
5
6
3
3
8
4
4
10
5
5
7
VIDEO INPUTS
9 11
12
6
6
13
14
7
7
15
16
8
8
A-16
P-16
1
V16
2
EXPANSION PORTS
9
9
3
4
10
10
5
6
11
11
7
8
12
12
9
10
13
13
11
12
14
14
13
14
15
15
15
16
16 In 1-8
Input Triggers
1 Gnd
In 6/14
In 5/13
In 4/12
In 3/11
In 7/15
In 8/16
Gnd
In 1/9
In 2/10
A-16 • Audio Input Module
Balanced
Audio Page
Input (600 Ω)
1
Com
2
(+)
3
(-)
Trigger
5-24V
AC•DC
4
(+)
5
(-)
2 Fdbk
3 Cntrl
4 +V
ADA Bus®
16
In 9-16
+12VDC Outputs
Paging Input/Trigger
Zones 1- 6 & 7-12
Zones 1-6
In 5/11
In 3/9
Gnd
In 2/8
P-16 • Preamplifier Module
Zones 13-16
+12VDC Output
Gnd
(-)
13
(+)
14
(+)
15
(+)
16
(+)
230V
115V
1/2 ASB
115V~
1/4 ASB
230V~
115 V
Out 1-8
Output Triggers
Out 6/14
Out 5/13
Out 4/12
Out 3/11
Out 7/15 Out 8/16
Gnd
Out 1/9
Out 2/10
V-16 • Video I/O Module
Programmed Video
Input Triggers
Gnd
(+)
5-24V AC•DC
1
(+)
2
(+)
3
(+)
4
(+)
Switch
AC
(10A)
Out 9-16
+12VDC Outputs
Input Triggers
Main
AC
Input
Network Control I/O
WARNING! Risk Of Hazardous Energy!
Make Proper Connections.
AVERTISSEMENT! Energie Electrique
Dangereuse!
Faire Des Connexions Propres
Pour L'Hautparleur.
Voir La Notice De Fonctionnement.
CAUTION: Disconnect Supply
Cord Before Servicing.
ATTENTION: Debrancher
Avant Le Depannage.
115V~/60Hz • 230V~/50Hz
500 WATTS MAX
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
ATTENTION!
RISQUE DE CHOC ELECTRIQUE.
NE PAS OUVRIR
MADE IN U.S.A.
AVP-16 MR Controller
120-240 VAC
50-60 Hz
Set Shunting Pins To Engage AC With Zone Or Source Numbers 1-8
1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8
TO 9 PIN "D"
DELTA-88
1 2 3 4
Sources 9-16
AC Switching
& IR Control
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
ATTENTION!
RISQUE DE CHOC ELECTRIQUE.
NE PAS OUVRIR
MADE IN U.S.A.
ACC-48
QUAD AC CONTROLLER
1.
2.
1000 WATTS
MAX TOTAL
Delta-88 9 Pin "D" programmed for source AC control. - Set one shunting pin per AC outlet according to source inputs. Set 3 pins for MT-3000.
Delta-88 9 Pin "D" programmed for zone AC control. - Set one shunting pen per AC outlet according to zone numbers. Set all shunting pins on one AC Outlet for All-On source AC control when not using an ACC-3000.
120-240 VAC
50-60 Hz
Set Shunting Pins To Engage AC With Zone Or Source Numbers 1-8
1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8
TO 9 PIN "D"
DELTA-88
1 2 3 4
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
ATTENTION!
RISQUE DE CHOC ELECTRIQUE.
NE PAS OUVRIR
MADE IN U.S.A.
ACC-48
QUAD AC CONTROLLER
1.
2.
1000 WATTS
MAX TOTAL
Delta-88 9 Pin "D" programmed for source AC control. - Set one shunting pin per AC outlet according to source inputs. Set 3 pins for MT-3000.
Delta-88 9 Pin "D" programmed for zone AC control. - Set one shunting pen per AC outlet according to zone numbers. Set all shunting pins on one AC Outlet for All-On source AC control when not using an ACC-3000.
IRL-5000
Address 2
RS-232
Pins
2=Tx
3=Rx
5=Com
IR Repeating Only
40KHz IR Repeat
Frequency Repeater
IR - Serial
Serial
Data Only
1 2 3 4
Gnd Rx Tx +15V
ADA Bus®
ADA/232
Source Ports: 1 2 3 4 5 6 7 8
Data/Carrier
Off
Norm Invert
Repeater
IR - Serial
Serial
Data Only
IR Flasher=Remove Jumper
Serial Direct=Insert Jumper
Off Norm Invert
RS-232
ADA Bus
Repeater
IR - Serial
Serial
Data Only
Off Norm Invert
Repeater
IR - Serial
Serial
Data Only
1
2
3
Off Norm Invert
Repeater
IR - Serial
Serial
Data Only
4
5
PGM DEL
IRL-5000
Source Controller
Power On/Off IR Macro
Connect To Mainframe
Source DC Triggers &
ACC-48 AC Controllers
Off
Norm Invert
Repeater
IR - Serial
Serial
Data Only
Off Norm Invert
Repeater
IR - Serial
Serial
Data Only
6
7
CON ERR
Off
Norm Invert
Repeater
IR - Serial
Serial
Data Only
Off Norm Invert 8
- 6 -
The ACC-48 features jumper pins (shunting pins) that determine which sources the outlet will activate with. Several jumper pins can be inserted for any one outlet. In the case of the Trinity
Triple Tuner, the Trinity has only one AC cord, even though it acts like three components to the system. As such, three jumper pins would be inserted into the Trinity Tuner’s ACC-48 outlet such that, whenever any of the three tuner modules is accessed, the tuner will get AC and engage.
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
1 This device may not cause harmful interference.
2 This device must accept any interference received, including interference that may cause undesired operation.
TUNER 1
AUDIO OUTPUT
T
RINITY
T
RIPLE
TUNER 2
AUDIO OUTPUT
T
UNER
TUNER 3
AUDIO OUTPUT
L L L
ANTENNA ANTENNA ANTENNA
• ICC - I C
BUS
•
OMPONENT
C
OMMUNICATION
®
The Trinity Does Not
Require a BI-3000.
IR Flasher
Input
ADA Bus™
1 2 3 4
115V
115 V
230V
115V 2/10A S.B.
230V 1/10 AS.B.
CAUTION: DISCONNECT SUPPLY
CORD BEFORE SERVICING.
ATTENTION: DEBRANCHER AVANT
LE DEPANNAGE.
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
ATTENTION!
RISQUE DE CHOC ELECTRIQUE.
NE PAS OUVRIR
MADE IN U.S.A.
AC INPUT
R R R
OUTPUT
LEVEL
OUTPUT
LEVEL
OUTPUT
LEVEL
Voltage Selector
120-240 VAC
50-60 Hz
Set Shunting Pins To Engage AC With Zone Or Source Numbers 1-8
1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8
1 2 3 4
TO 9 PIN "D"
DELTA-88
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
ATTENTION!
RISQUE DE CHOC ELECTRIQUE.
NE PAS OUVRIR
MADE IN U.S.A.
ACC-48
QUAD AC CONTROLLER
1.
2.
1000 WATTS
MAX TOTAL
Delta-88 9 Pin "D" programmed for source AC control. - Set one shunting pin per AC outlet according to source inputs. Set 3 pins for MT-3000.
Delta-88 9 Pin "D" programmed for zone AC control. - Set one shunting pen per AC outlet according to zone numbers. Set all shunting pins on one AC Outlet for All-On source AC control when not using an ACC-3000.
120-240 VAC
50-60 Hz
Set Shunting Pins To Engage AC With Zone Or Source Numbers 1-8
1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8
TO 9 PIN "D"
DELTA-88
1 2 3 4
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
ATTENTION!
RISQUE DE CHOC ELECTRIQUE.
NE PAS OUVRIR
MADE IN U.S.A.
ACC-48
QUAD AC CONTROLLER
1.
2.
1000 WATTS
MAX TOTAL
Delta-88 9 Pin "D" programmed for source AC control. - Set one shunting pin per AC outlet according to source inputs. Set 3 pins for MT-3000.
Delta-88 9 Pin "D" programmed for zone AC control. - Set one shunting pen per AC outlet according to zone numbers. Set all shunting pins on one AC Outlet for All-On source AC control when not using an ACC-3000.
- 7 -
Party Functions
There are four “Party” functions which when activated, cause rooms to switch to the selected source. As room outputs are programmed to track party groups, this feature is discussed under P-16 features.
Paging Features
The A-16 also features a seventeenth input for paging. Unlike other systems, the Suite 16’s paging feature is extensive. Included are three types of triggers (audio sensing, voltage sensing, and serial controlled). Each trigger activates its own “paging group” of which there are eight (six paging groups can be activated serially). Each paging group can be disabled
(from ever occurring) and any room can be a member of none, one, several or all paging group(s). Serial control also permits room specific paging (for room-to-room paging). When a paging trigger is activated, rooms that are directed to engage with that page load all current settings into memory and then recall a paging volume preset, while setting tone controls to flat and filters off. When the page is terminated, the previous settings are recalled. While each paging feature needs to be turned off in order to return the room to normal operation, a user can also clear a page while in progress by selecting another source in that room or by turning the room off (This will remove the page for only that room. If other rooms are part of this paging group, they will still page through.). Resetting power to the Suite 16, will also reset all paging triggers to standby.
Paging Audio Input
This balanced audio input (600 Ω) is accessed through the removable 5-pin screw terminal connector on the far right side of the A-16
Module. Here Pin 1 is common (shield), Pin 2 is Positive (+), and
Pin 3 is Negative (-). This input can be connected to the audio output of telephone systems or some other type of microphone mixing device.
s
8/16 d
1/9
2/10
A-16 • Audio Input Module
Balanced
Audio Page
Input (600 Ω)
1
Com
2
(+)
3
(-)
Trigger
5-24V
AC•DC
4
(+)
5
(-) ts
Paging Input/Trigger
Paging Compressor
The A-16 also features a paging compressor that limits the level of the audio paging signal regardless of the actual input level. There is a trim pot to adjust the compressor, which is located behind the AVP-16’s removable front panel plexi-glass plate.
Paging Volume Preset
Each room has a paging volume preset that is set in software. This volume level is independent of the volume level of the music playing in the room.
s
Paging Triggers
The A-16 features two non-serial controlled paging triggers. The first is based on audio sensing through the balanced audio input previously described. There is a trim pot to adjust sensitivity of the audio sensing trigger, which is located behind the AVP-16’s removable front panel plexi-glass plate. When engaged, the audio sens-
8/16 d
1/9
2/10 ts
A-16 • Audio Input Module
Balanced
Audio Page
Input (600 Ω)
1
Com
2
(+)
3
(-)
Trigger
5-24V
AC•DC
4
(+)
5
(-)
Paging Input/Trigger ing trigger engages a group of rooms. The rooms that are activated with the audio sensing trigger are predetermined in software by the installer. The audio sensing trigger can be defeated in software so that it never triggers the paging function. The audio sensing trigger, once activated, must be deactivated in order to return the rooms to their prior state.
- 8 -
The second trigger is a low voltage input trigger (3-24V AC or DC). It connects to the A-16 on the removable 5-pin screw terminal connector on the far right side of the A-16 Module (Pin 4 is [+] and Pin 5 is [-], polarity does not matter for an AC trigger). The low voltage trigger, once activated, must be deactivated in order to return the rooms to their prior state.
The A-16 Paging trigger can also be controlled serially. Here the paging functions are much more robust. There are a total of six paging room groups. Rooms can be programmed by the installer in software to either be part of one or several groups. Rooms can also be excluded from all pages. Also, individual rooms can be selected to receive a page. This will permit room specific paging. Again, once a serial trigger is engaged, it must be deactivated in order for the room to return to its prior state.
P-16 Preamplifier Module
The P-16 Preamplifier Module is the most advanced stereo preamplifier for multi-room use.
With special attention placed on the sound quality of the Suite 16 System, the P-16 has a host of features that are ideal for custom installation. The first AVP-16 can house one or two P-
16’s for up to 32 zones. Additional P-16s can be installed into additional AVP-16s for up to 96 zones (six P-16 Modules).
L
R
1 2 3 4 5 6 7 8
P-16
9 10 11 12 13 14 15 16
Zones 1- 6 & 7-12
Zones 1-6
In 6/12 TO PTM-1225/1260
In 5/11
In 4/10
In 3/9
Gnd
In 1/7
In 2/8
P-16 • Preamplifier Module
Zones 13-16
+12VDC Output
Gnd
(-)
13
(+)
14
(+)
15
(+)
16
(+)
Zones 7-12
+12VDC Outputs
Audio Outputs
The P-16 houses sixteen stereo RCA audio outputs. Each audio output operates as its own zone with independent: source selection; on, off, and muting; volume, bass and treble control; maximum volume level; balance control; and even loudness and stereo enhancement filters.
The P-16 can be set so that zones down-mix to mono. Zones can also be set to provide either a variable (signal to amplifiers) or fixed (signal to home theater preamplifiers or recording devices) level audio output.
Input Selection
Each zone of the P-16 can directly access any one of the sixteen audio inputs independently of each other. A zone turns on with an input selection. There are a total of eighteen serial commands for a zones input selection, sixteen for the direct access of sources, and two more commands for input up and input down selection.
Volume and Tone Controls
Each zone of the P-16 features independent volume, bass, and treble control. Serially, each of these features has three commands, up, down and direct. As expected, the up and down functions will raise or lower these parameters. The direct function is a numeric command that immediately engages that specific level. This feature is ideal when creating sliders on touch screen controls.
- 9 -
Volume and Tone Presets
Each zone has four volume and four tone presets. Each of these eight presets has a serial command to store the settings and another to recall these settings. The tone presets recall and store both a bass and treble level as well as Loudness and Stereo Enhancement filter settings. ADA suggests recalling both a Volume and Tone Preset when a room is turned on to ensure that acoustic levels are appropriate.
Maximum Zone Volume Level
To prevent speaker damage, the installer can set in software, a zones maximum volume level such that the user can never exceed this volume level.
Paging Volume Level
Because audio being paged has different characteristics than music, special concern needs to be placed on the level of the audio signal during a page. If for example, music is playing loud in a zone, should a page be introduced at the same volume level, one might expect to speaker damage. To prevent this from occurring, each zone of the P-16 features a paging volume preset level. During a page, the zone will set all tone controls flat, turn off all filters, and recall the paging volume preset. Once the page is terminated, the previous settings are recalled if that zone was previously on.
Balance Control
In some zones, it will be necessary to alter the balance of the audio levels between speakers.
To facilitate in this matter, the P-16 features a powerful balance control section. There are three serial commands that control a room’s balance level: balance left, balance right, and balance equal. Balance equal will instantly center the audio between the two speakers. There are also two balance presets with four serial commands: balance preset 1 recall and store, and balance preset 2 recall and store. If a room’s balance needs to be altered from the equal position, ADA suggests storing the appropriate balance level in one of the two presets and recalling it on start up.
Zone Turn-On Preset
Each zone of the P-16 can be set to either turn on to its last used state or presets 1. When engaging with preset 1, Volume Preset 1, Tone Preset 1, and Balance Preset 1 are all recalled as the zone turns on. This provides the installer with the ability to load into memory, ideal acoustic characteristics when a room is first turned on. This will prevent a room from coming on with inappropriate volume, bass, treble, or balance settings, even if these settings where used the last time the room was on.
Party Zone Groups
There are four party zone groups which are set, cleared, and engaged serially. This feature permits rooms to track the same source component and can be used to engage several zones to the same source during a party. The feature can also be used for rooms that are open to each other. In this application, it may be inappropriate to have one source component playing in one room, while another is playing in an adjacent area because of interference. As such, these rooms can have their control source selection buttons transmit one of the four party commands. All rooms set to track that specific party function will turn to the same source. For example, an entry foyer, living room, and dining room are open and adjacent to each other. Each room has its own control. While it is desired that each area maintain independent volume, tone, balance control, etc., it is not ideal that each area be capable of
- 10 -
playing different sources at the same time. As such, the installer can program the controls in these rooms to send party input commands instead of the standard input commands. As such, whenever someone selects CD in the living room, the dining room and entry foyer will turn on to CD as well. There are no restrictions as to which rooms track which of the four party presets or whether they do not track any. Rooms can track several party presets as well.
Rooms do not have to have a control to engage with a party function from another room.
Mute and Room Off/All Off
Each zone features three serial mute commands: mute on, mute off, and mute toggle. There are also two additional commands involving audio, room off and all off.
Stereo Enhancement and Loudness Contour Filters.
Each zone provides the option to engage/disengage two filters. These filters are used when either speaker size, placement, or room acoustics are less than perfect. The Stereo Enhancement filter opens the sound stage between two speakers. If speakers are extremely close together or in a position that is less than ideal, this filter may be of use. The Loudness
Contour Filter is used to enhance the bass output of speakers. If speakers have small bass drivers or are in a position that baffles most of the bass information, this filter may be of use.
Both filter settings are encompassed in the Tone Presets.
Stereo & Mono
Here the P-16 is uniquely outfitted with both software and hardware options. Serially, one of three preamplifier mixing options exist: stereo, mono input left, and mono input right. Stereo
(normally used), passes right and left channel audio inputs to the preamplifier stage. Mono input left or right, pass only that channels information to the preamplifier stage. This feature is useful if stereo recordings contain two completely different channels of information whereby it is desired to eliminate one channel completely (language recordings).
While the software features may be of little use, the hardware mono/stereo feature is extremely important. While most rooms will most likely be set (hardware) for stereo (the P-16s default state), it may be desirable for some zones to output a mono signal. Examples of such areas may include hallways, galleries, outdoor areas, or even rooms that might contain only one speaker (sauna). To down-mix to mono, the installer must alter a jumper-pin located on the P-16 Module. This will require powering down the AVP-16, removing the P-16 Module, locating the appropriate jumper (shunting pin) on the P-16 circuit board and inserting the jumper. At this time, that zones audio output will be same on both right and left channels, regardless of the separation of the input signal.
Variable and Fixed Outputs
The P-16 also permits any zone to have its output at either a fixed audio level (unprocessed) or variable level (all previously mentioned preamplifier features). This is extremely useful when desiring to include home theater systems or recording devices onto a Suite 16. Normally, the P-16s are inserted into an AVP-16 where zones 1-12 are set to variable (for multiroom audio) and zones 13-16 are set to fixed (the line-level audio signal can be routed to the input of a high-end home theater preamplifier, A/V receiver, high-end two channel preamplifier, TV audio input, or recording device). To alter any zone, you must locate that zones appropriate jumper pins (shunting pins) which are located on the P-16 Module circuit board and move them to the alternate setting. There are two jumper pins per zone (for left and right channels). This will require powering down the AVP-16 and removing the P-16 Module.
- 11 -
Low Voltage Triggers
The P-16 features three low voltage trigger outputs: two 9-pin “D” type connectors (these are not RS-232) and one removable five-pin screw terminal connector. The top 9-pin “D” connector provides a single ground pin and six pins that go to +12VDC individually with respect to zones 1-6. Likewise, the bottom 9-pin “D” connector provides a single ground pin and six pins that to go +12VDC for zones 7-
12. These zone triggers can connect directly to the PTM-1225 or
PTM-1260 Twelve Channel Power Amplifiers. These amplifiers utilize the zone triggers to mute and unmute zones as they are engaged by the P-16. A standard straight-through 9-Pin “D” male-tomale cable can be used (both PTM-1225 and PTM-1260 Power
Amplifiers come with this cable).
Zones 1- 6 & 7-12 nes 1-6
In 6/12 TO PTM-1225/1260
In 5/11
In 4/10
In 3/9
Gnd
In 1/7
In 2/8
P-1
Z
+1
Gn
(-) es 7-12
+12VDC Outputs
12
The removable 5-pin screw terminal connector is used to provide a low voltage trigger for zones 13-16. Here, pin 1 is ground (-), pin 2 engages (+12VDC) with zone 13, pin 3 engages with zone 14,. pin 4 engages with zone 15, and pin 5 engages with zone 16. ADA provides the ACC-3 Low Voltage Triggered AC Controller which can be used to turn on any size ADA power amplifier.
1260 d
1/7
2/8
P-16 • Preamplifier Mo
Zones 13-16
+12VDC Output
Gnd
(-)
13
(+)
14
(+)
15
(+)
16
(+) ts
Power Amplifier Options
Two ADA power amplifiers offer easy connections directly to the P-16 Module.
The PTM-1225 will provide medium power to up to six zones (25W/Ch @ 8 Ω, 45W/
Ch @ 4 Ω, stable to 2Ω).
The PTM-1260 will provide high power to up to six zones
(Unbridged - 85W/Ch @ 8 Ω,
135W/Ch @ 4 Ω, stable to
2 Ω). You can opt to use two
PTM-1225s, one PTM-1225 and one PTM-1260, or two
PTM-1260s.
The PTM-1260 can also be set so that channel pairs are bridged, from 12 to 10, 8, or
6 channels. In bridged mode power increases to 350W/Ch into 4 Ω. In bridged mode, the
PTM-1260 is stable to 4 Ω.
480 WATTS MAX
4 ASB - 115V~
2 ASB - 230V~
Bypass
Trigger
115V~/60Hz
230V~/50Hz
All Zones
12VDC
1(-) 2(+)
Individual
Zones
VOLTAGE
SELECTOR
ZONE 1
16-2
Ω
+
R
+
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
ATTENTION!
RISQUE DE CHOC ELECTRIQUE.
NE PAS OUVRIR
MADE IN U.S.A.
10K Ω
L
R
WARNING! Risk Of Hazardous Energy!
Make Proper Connections.
AVERTISSEMENT! Energie Electrique Dangereuse! Faire Des
Connexions Propres Pour L'Hautparleur.
Voir La Notice De Fonctionnement.
ZONE 2
16-2
Ω
+
R
- -
L
+
CAUTION: Disconnect Supply Cord Before Servicing.
ATTENTION: Debrancher Avant Le Depannage.
DO NOT SHORT OUTPUTS!
L
+
ZONE 3
16-2
Ω
- -
L
+
L
ZONE 4
16-2
+
R
Ω
- -
L
+
R R
10K Ω 10K Ω
PTM-1225
12 Channel Power Amp
L
10K Ω
R
ZONE 5
16-2
Ω
+
R
- -
L
+
L
10K Ω
R
+
ZONE 6
16-2
Ω
- -
L
+
L
10K Ω
R
PTM-1260
L
S TEREO
R
B
RIDGED
COM
-
Z
ONE
1
L
EFT
/ 1
+
COM
+
B
RIDGED
/ 1
-
-
R
IGHT
/ 2
+
COM
PTM-1260 P
OWER
A
MP
Z
ONE
2
L
-
R
IGHT
/ 4
+
S TEREO
R
EFT
/ 3
+
L
S TEREO
R
B
RIDGED
COM
+
B
RIDGED
/ 2
-
COM
B
RIDGED
-
B
RIDGED
/ 4
+
COM
+ + -
R
IGHT
/ 7 L / 8
Z
ONE
4
WARNING! RISK OF HAZARDOUS
ENERGY! MAKE PROPER SPEAKER
CONNECTIONS.
B
RIDGED
R
S
TEREO
L
COM
-
B
RIDGED
/ 5
+
COM
B RIDGED
+ + -
R
S
TEREO
R
IGHT
/ 9 L
EFT
/ 10
L
Z
ONE
5
AVERTISSEMENT! ENERGIE ELECTRIQUE DANGEREUSE!
FAIRE DES CONNEXIONS PROPRES POUR
L'HAUTPARLEUR. VOIR LA NOTICE DE FONCTIONNEMENT.
COM
+
R
IGHT
/ 11
CAUTION:
ATTENTION:
-
-
-
Z
ONE
3
L
EFT
/ 5
+
COM
B
RIDGED
/ 6
+
+
+
B
RIDGED
/ 3
-
-
R
IGHT
/ 6
+
COM
STANDBY
REPLACE WITH SAME VALUE FUSE
2/10A S.B.~115V
1/10A S.B.~230V
COM
-
B RIDGED
R
S
TEREO
EFT
/ 12
L
Z
ONE
6
DISCONNECT SUPPLY CORD BEFORE SERVICING.
DEBRANCHER AV LE DEPANNAGE.
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
ATTENTION!
RISQUE DE CHOC ELECTRIQUE.
NE PAS OUVRIR
MADE IN U.S.A.
A
LL
Z
ONES
DC T
1 2
(-) (+)
9-P
IN
D C
ONNECTOR
O PERATES D ELTA -88
Z
ONE
T
1-6 O
NLY
S WITCH
VOLTAGE
SWITCH
115 V~ /
230 V~
B
YPASS
E
XTERNAL
DC T
RIGGERS
POWER
115 V~ / 230 V~
50 Hz / 60 Hz
MAIN
REPLACE
WITH SAME
VALUE FUSE
1500W
VOLTAGE SWITCH
115 V~ / 230 V~
10A S.B.~115V
5A S.B.~230V
- 12 -
L
R
1 2 3 4 5 6 7 8 9
P-16
10 11 12 13 14 15 16
Zones 1- 6 & 7-12
Zones 1-6
In 6/12 TO PTM-1225/1260
In 5/11
In 4/10
In 3/9
Gnd
In 1/7
In 2/8
P-16 • Preamplifier Module
Zones 13-16
+12VDC Output
Gnd
(-)
13
(+)
14
(+)
15
(+)
16
(+)
Zones 7-12
+12VDC Outputs
480 WATTS MAX
4 ASB - 115V~
2 ASB - 230V~
Bypass
Trigger
115V~/60Hz
230V~/50Hz
All Zones
12VDC
1(-) 2(+)
Individual
Zones
VOLTAGE
SELECTOR
ZONE 1
16-2
Ω
+
R
- -
L
+
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
ATTENTION!
RISQUE DE CHOC ELECTRIQUE.
NE PAS OUVRIR
MADE IN U.S.A.
10K
Ω
L
R
WARNING! Risk Of Hazardous Energy!
Make Proper Connections.
AVERTISSEMENT! Energie Electrique Dangereuse! Faire Des
Connexions Propres Pour L'Hautparleur.
Voir La Notice De Fonctionnement.
CAUTION: Disconnect Supply Cord Before Servicing.
ATTENTION: Debrancher Avant Le Depannage.
DO NOT SHORT OUTPUTS!
ZONE 2
16-2
Ω
+
R
- -
L
+
L
ZONE 3
16-2
Ω
+
R
- -
L
+
L
ZONE 4
16-2
Ω
+
R
- -
L
+
R R
10K
Ω
10K
Ω
PTM-1225
12 Channel Power Amp
10K
Ω
L
R
ZONE 5
16-2
Ω
+
R
- -
L
+
L
10K
Ω
R
ZONE 6
16-2
Ω
+
R
- -
L
+
L
10K
Ω
R
480 WATTS MAX
4 ASB - 115V~
2 ASB - 230V~
Bypass
Trigger
115V~/60Hz
230V~/50Hz
All Zones
12VDC
1(-) 2(+)
Individual
Zones
VOLTAGE
SELECTOR
ZONE 1
16-2
Ω
+
R
- -
L
+
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
ATTENTION!
RISQUE DE CHOC ELECTRIQUE.
NE PAS OUVRIR
MADE IN U.S.A.
10K Ω
L
R
WARNING! Risk Of Hazardous Energy!
Make Proper Connections.
AVERTISSEMENT! Energie Electrique Dangereuse! Faire Des
Connexions Propres Pour L'Hautparleur.
Voir La Notice De Fonctionnement.
ZONE 2
16-2
Ω
+
R
- -
L
+
CAUTION: Disconnect Supply Cord Before Servicing.
ATTENTION: Debrancher Avant Le Depannage.
DO NOT SHORT OUTPUTS!
L
ZONE 3
16-2
Ω
+
R
- -
L
+
L
ZONE 4
16-2
Ω
+
R
- -
L
+
R R
10K Ω 10K Ω
PTM-1225
12 Channel Power Amp
10K Ω
L
R
ZONE 5
16-2
Ω
+
R
- -
L
+
10K Ω
L
R
ZONE 6
16-2
Ω
+
R
- -
L
+
L
10K Ω
R
Both the PTM-1225 and PTM-1260 feature the six zone low voltage trigger, that mutes zones when they are not in use. Connection of this trigger is easy with the provided 9-pin D style ribbon cables. You can opt to use two PTM-1225s for medium power or two PTM-1260s for high power. You can also use one of each as shown on the next page.
L
1
R
2 3 4 5 6 7 8
P-16
9 10 11 12 13 14 15 16
Zones 1- 6 & 7-12
Zones 1-6
In 6/12 TO PTM-1225/1260
In 5/11
In 4/10
In 3/9
Gnd
In 1/7
In 2/8
P-16 • Preamplifier Module
Zones 13-16
+12VDC Output
Gnd
(-)
13
(+)
14
(+)
15
(+)
16
(+)
L
S TEREO
R
B RIDGED
COM
+ -
-
Z
ONE
1
L
EFT
/ 1
+
COM
-
B
RIDGED
/ 4
+
+
+
B / 1
-
COM
-
R
IGHT
/ 7 L
EFT
/ 8
Z
ONE
4
WARNING! RISK OF HAZARDOUS
ENERGY! MAKE PROPER SPEAKER
CONNECTIONS.
-
R
IGHT
/ 2
+
B
RIDGED
R
S
TEREO
L
COM
PTM-1260 P
OWER
A
MP
Z
ONE
2
L / 3
L
+ -
R
IGHT
/ 4
+
S TEREO
COM
+
R
B RIDGED
-
COM
-
B
RIDGED
/ 5
+
+
+
B
RIDGED
/ 2
-
COM
-
B RIDGED
COM
R
S
TEREO
/ 9 L
EFT
/ 10
Z
ONE
5
L
AVERTISSEMENT! ENERGIE ELECTRIQUE DANGEREUSE!
FAIRE DES CONNEXIONS PROPRES POUR
L'HAUTPARLEUR. VOIR LA NOTICE DE FONCTIONNEMENT.
L
S TEREO
COM
+
R
B RIDGED
R
IGHT
/ 11
CAUTION:
ATTENTION:
-
Z
ONE
3
L
EFT
/ 5
+
+
B
RIDGED
/ 3
-
-
R
IGHT
/ 6
+
-
-
COM
B
RIDGED
/ 6
+
+
COM
-
B RIDGED
COM
R
S
TEREO
L
EFT
/ 12
Z
ONE
6
L
DISCONNECT SUPPLY CORD BEFORE SERVICING.
DEBRANCHER AV LE DEPANNAGE.
STANDBY
REPLACE WITH SAME VALUE FUSE
2/10A S.B.~115V
1/10A S.B.~230V
VOLTAGE
SWITCH
115 V~ /
230 V~
B
YPASS
T
RIGGER
S
WITCH
A LL Z ONES
DC T RIGGER
1 2
(-) (+)
9-P IN D C ONNECTOR
O D
Z ONE T RIGGERS
1-6 O NLY
E
XTERNAL
DC T
RIGGERS
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
ATTENTION!
POWER
115 V~ / 230 V~
50 Hz / 60 Hz
MADE IN U.S.A.
MAIN
REPLACE
WITH SAME
VALUE FUSE
VOLTAGE SWITCH
115 V~ / 230 V~
10A S.B.~115V
5A S.B.~230V
1500W
+
L
S
TEREO
R
B
RIDGED
COM
-
-
Z ONE 1
L
EFT
/ 1
+
COM
-
B
RIDGED
/ 4
+
+
+
B / 1
-
COM
-
R
IGHT
/ 7 L
EFT
/ 8
Z ONE 4
WARNING! RISK OF HAZARDOUS
ENERGY! MAKE PROPER SPEAKER
CONNECTIONS.
-
R
IGHT
/ 2
+
B
RIDGED
R
S
TEREO
L
COM
PTM-1260 P
OWER
A
MP
L
S
TEREO
-
Z ONE 2
L / 3
+ -
R
IGHT
/ 4
+
R
B
RIDGED
COM
+ -
COM
-
B
RIDGED
/ 5
+
+
+
B
RIDGED
/ 2
-
COM
-
B
RIDGED
COM
R
S TEREO
/ 9 L
EFT
/ 10
L
Z ONE 5
AVERTISSEMENT! ENERGIE ELECTRIQUE DANGEREUSE!
FAIRE DES CONNEXIONS PROPRES POUR
L'HAUTPARLEUR. VOIR LA NOTICE DE FONCTIONNEMENT.
L
S
TEREO
COM
+
R
B
RIDGED
R
IGHT
/ 11
CAUTION:
ATTENTION:
-
-
Z ONE 3
L
EFT
/ 5
+ -
R
IGHT
/ 6
+
-
COM
B
RIDGED
/ 6
+
+
+
B
RIDGED
/ 3
COM
-
-
B
RIDGED
COM
R
S TEREO
L
EFT
/ 12
L
Z ONE 6
DISCONNECT SUPPLY CORD BEFORE SERVICING.
DEBRANCHER AV LE DEPANNAGE.
STANDBY
REPLACE WITH SAME VALUE FUSE
2/10A S.B.~115V
1/10A S.B.~230V
VOLTAGE
SWITCH
115 V~ /
230 V~
B
YPASS
T
RIGGER
S
WITCH
A
LL
Z
ONES
DC T
RIGGER
1 2
(-) (+)
9-P
IN
D C
ONNECTOR
O D
Z
ONE
T
RIGGERS
1-6 O
NLY
E
XTERNAL
DC T
RIGGERS
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
POWER
115 V~ / 230 V~
50 Hz / 60 Hz
ATTENTION!
RISQUE DE CHOC ELECTRIQUE.
NE PAS OUVRIR
MADE IN U.S.A.
MAIN
REPLACE
WITH SAME
VALUE FUSE
VOLTAGE SWITCH
115 V~ / 230 V~
10A S.B.~115V
5A S.B.~230V
1500W
- 13 -
The diagram below shows that zones 1-6 are running on medium power using a PTM-1225, while zones 7-12 are running on high power using the PTM-1260 (as a six zone/twelve channel amplifier - unbridged). When duplicating this scenario, it does not matter whether the
PTM-1260 is running zones 1-6 or 7-12.
L
1 2 3 4 5 6 7 8
P-16
9 10 11 12 13 14 15 16
Zones 1- 6 & 7-12
Zones 1-6
In 6/12 TO PTM-1225/1260
In 5/11
In 4/10
In 3/9
Gnd
In 1/7
In 2/8
P-16 • Preamplifier Module
Zones 13-16
+12VDC Output
Gnd
(-)
13
(+)
14
(+)
15
(+)
16
(+)
R
480 WATTS MAX
4 ASB - 115V~
2 ASB - 230V~
Bypass
Trigger
115V~/60Hz
230V~/50Hz
All Zones
12VDC
1(-) 2(+)
Individual
Zones
VOLTAGE
SELECTOR
ZONE 1
16-2
+
R
- -
L
+
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
ATTENTION!
RISQUE DE CHOC ELECTRIQUE.
NE PAS OUVRIR
MADE IN U.S.A.
10K
L
R
WARNING! Risk Of Hazardous Energy!
Make Proper Connections.
AVERTISSEMENT! Energie Electrique Dangereuse! Faire Des
Connexions Propres Pour L'Hautparleur.
Voir La Notice De Fonctionnement.
ZONE 2
16-2
+
R
- -
L
+
CAUTION: Disconnect Supply Cord Before Servicing.
ATTENTION: Debrancher Avant Le Depannage.
DO NOT SHORT OUTPUTS!
L
ZONE 3
16-2
+
R
- -
L
+
L
ZONE 4
16-2
+
R
- -
L
+
R R
10K 10K 10K
PTM-1225
12 Channel Power Amp
L
R
ZONE 5
16-2
+
R
- -
L
+
10K
L
R
ZONE 6
16-2
+
R
- -
L
+
10K
L
R
COM
+
L
S TEREO
R
B
RIDGED
-
-
Z
ONE
1
L
EFT
/ 1
+
COM
-
RIDGED
/ 4
+
+
+
RIDGED
/ 1
-
COM
-
R
IGHT
/ 7 L
EFT
/ 8
Z ONE 4
WARNING! RISK OF HAZARDOUS
ENERGY! MAKE PROPER SPEAKER
CONNECTIONS.
-
R
IGHT
/ 2
+
B
RIDGED
R
S
TEREO
L
COM
PTM-1260 P
OWER
A
MP
Z
ONE
2
L
EFT
/ 3
L
+ -
/ 4
+
S TEREO
R
B RIDGED
COM
COM
-
RIDGED
/ 5
+
+
RIDGED
/ 2
-
COM
B
RIDGED
COM
+ + -
R
S
TEREO
R
IGHT
/ 9 L
EFT
/ 10
Z
ONE
5
L
AVERTISSEMENT! ENERGIE ELECTRIQUE DANGEREUSE!
FAIRE DES CONNEXIONS PROPRES POUR
L'HAUTPARLEUR. VOIR LA NOTICE DE FONCTIONNEMENT.
L
S TEREO
COM
+
R
B RIDGED
/ 11
CAUTION:
ATTENTION:
-
-
-
COM
Z
ONE
3
L
EFT
/ 5
RIDGED
/ 6
+
+
+
RIDGED
/ 3
COM
-
-
IGHT
/ 6
+
COM
B
RIDGED
+ -
R
S
TEREO
L
EFT
/ 12
L
Z
ONE
6
DISCONNECT SUPPLY CORD BEFORE SERVICING.
DEBRANCHER AV LE DEPANNAGE.
STANDBY
REPLACE WITH SAME VALUE FUSE
2/10A S.B.~115V
1/10A S.B.~230V
VOLTAGE
SWITCH
115 V~ /
230 V~
B
YPASS
T
RIGGER
S
WITCH
A LL Z ONES
DC T RIGGER
1 2
(-) (+)
9-P IN D C ONNECTOR
PERATES D ELTA -88
Z ONE T RIGGERS
1-6 O NLY
E
XTERNAL
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
ATTENTION!
POWER
115 V~ / 230 V~
50 Hz / 60 Hz
MADE IN U.S.A.
MAIN
REPLACE
WITH SAME
VALUE FUSE
VOLTAGE SWITCH
115 V~ / 230 V~
10A S.B.~115V
5A S.B.~230V
1500W
Whether you are using the PTM-1225 or the PTM-1260 power amplifiers, you will need to connect the stereo line-level RCA audio cables between the P-16 Module and the amplifier inputs.
These cables are in addition to the ribbon cables that trigger the amplifier zones.
ADA suggests using cables that are of appropriate length that are non-directional.
Directional cable may cause ADA amplifiers to oscillate.
L
1
R
2 3 4 5 6 7 8 9
P-16
10 11 12 13 14 15 16
Zones 1- 6 & 7-12
Zones 1-6
In 6/12 TO PTM-1225/1260
In 5/11 Gnd
In 2/8
P-16 • Preamplifier Module
Zones 13-16
+12VDC Output
Gnd
(-)
13
(+)
14
(+)
15
(+)
16
(+)
480 WATTS MAX
4 ASB - 115V~
2 ASB - 230V~
Bypass
Trigger
115V~/60Hz
230V~/50Hz
All Zones
12VDC
1(-) 2(+)
Individual
Zones
VOLTAGE
SELECTOR
ZONE 1
16-2
Ω
+ R - - L +
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
ATTENTION!
RISQUE DE CHOC ELECTRIQUE.
NE PAS OUVRIR
MADE IN U.S.A.
L
R
WARNING! Risk Of Hazardous Energy!
Make Proper Connections.
AVERTISSEMENT! Energie Electrique Dangereuse! Faire Des
Connexions Propres Pour L'Hautparleur.
Voir La Notice De Fonctionnement.
CAUTION: Disconnect Supply Cord Before Servicing.
ATTENTION: Debrancher Avant Le Depannage.
DO NOT SHORT OUTPUTS!
ZONE 2
16-2
Ω
L +
L
ZONE 3
16-2
Ω
+ R - - L +
L
ZONE 4
16-2
Ω
+ R L +
R R
10K
Ω
PTM-1225
12 Channel Power Amp
L
R
ZONE 5
16-2
Ω
+ R - - L +
L
ZONE 6
16-2
Ω
+ R - - L +
R
L
R
480 WATTS MAX
4 ASB - 115V~
2 ASB - 230V~
Bypass
Trigger
115V~/60Hz
230V~/50Hz
All Zones
12VDC
1(-) 2(+)
Individual
Zones
VOLTAGE
SELECTOR
ZONE 1
+
R
16-2 Ω
- -
L
+
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
ATTENTION!
RISQUE DE CHOC ELECTRIQUE.
NE PAS OUVRIR
MADE IN U.S.A.
L
R
WARNING! Risk Of Hazardous Energy!
Make Proper Connections.
AVERTISSEMENT! Energie Electrique Dangereuse! Faire Des
Connexions Propres Pour L'Hautparleur.
Voir La Notice De Fonctionnement.
CAUTION: Disconnect Supply Cord Before Servicing.
ATTENTION: Debrancher Avant Le Depannage.
DO NOT SHORT OUTPUTS!
ZONE 2
16-2 Ω
L
+
L
ZONE 3
+
R
16-2 Ω
- -
L
+
L
+
ZONE 4
R
16-2 Ω
L
+
10K
Ω
R R
PTM-1225
12 Channel Power Amp
L
R
ZONE 5
+
R
16-2 Ω
- -
L
+
L
ZONE 6
+
R
16-2 Ω
- -
L
+
R
L
R
- 14 -
If zones require ultra-high power amplification, ADA suggests using PF-2501 Power Amplifiers (250W/Ch @ 8 Ω, 450W/Ch @ 4Ω, stable to 2Ω) along with an ACC-3 AC Controller. If zones require driving a great many speakers (up to sixteen pairs @ 8 Ω), ADA suggests using a PF-201 (60W/Ch @ 8 Ω, 240W/Ch @ 1/2Ω) along with an ACC-3 AC Controller. These amplifiers are optimally running on zones 13-16 because of screw termination connectivity of the ACC-3 to the P-16.
s 1- 6 & 7-12
L
R
1 2 3 4 5 6 7 8
P-16
9 10 11 12 13 14 15 16
Zones 1- 6 & 7-12
Zones 1-6
In 6/12 TO PTM-1225/1260
In 5/11
In 4/10
In 3/9
Gnd
In 1/7
In 2/8
P-16 • Preamplifier Module
Zones 13-16
+12VDC Output
Gnd
(-)
13
(+)
14
(+)
15
(+)
16
(+)
Zones 7-12
+12VDC Outputs
TO PTM-1225/1260
Gnd
In 1/7
In 2/8
P-16 • Preamplifier Module
Zones 13-16
+12VDC Output
Gnd
(-)
13
(+)
14
(+)
15
(+)
16
(+)
DC Outputs
CAUTION! DO NOT SHORT OUTPUTS!
INPUT
47K Ω
CH A
WARNING!
RISK OF HAZARDOUS
ENERGY!
MAKE PROPER SPEAKER
CONNECTIONS.
OUTPUT 1/2-16 Ω OUTPUT 1/2-16 Ω
+ + -
INPUT
47K Ω
CH B
AVERTISSEMENT! ENERGIE
ELECTRIQUE DANGEREUSE! FAIRE
DES CONNEXIONS PROPRES POUR
L'HAUTPARLEUR. VOIR LA NOTICE
DE FONCTIONNEMENT.
CAUTION: DISCONNECT SUPPLY CORD
BEFORE SERVICING.
ATTENTION: DEBRANCHER AVANT
LE DEPANNAGE.
PF-201 P
OWER
A
MP
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
ATTENTION!
RISQUE DE CHOC ELECTRIQUE.
NE PAS OUVRIR
MADE IN U.S.A.
POWER
115 V - 230 V
50 Hz - 60 Hz
VOLTAGE
SWITCH
115 V - 230 V
REPLACE
WITH SAME
VALUE FUSE
10A S.B.
ACC-3
PIN 1 (-)
PIN 2 (+)
LEFT RIGHT
PARALLEL
ALL
SPEAKERS
1 2 3 4
-A+ -B+
ACC-3
OUTDOOR
AREA
L
1
R
2 3 4 5 6 7 8
P-16
9 10 11 12 13 14 15 16
Zones 1- 6 & 7-12
Zones 1-6
In 6/12 TO PTM-1225/1260
In 5/11
In 4/10
In 3/9
Gnd
In 1/7
In 2/8
P-16 • Preamplifier Module
Zones 13-16
+12VDC Output
Gnd 13 14 15 16
(-) (+) (+) (+) (+)
Zones 7-12
+12VDC Outputs nes 1- 6 & 7-12
12 TO PTM-1225/1260
11
10
3/9
Gnd
In 1/7
In 2/8
P-16 • Preamplifier Module
Zones 13-16
+12VDC Output
Gnd
(-)
13
(+)
14
(+)
15
(+)
16
(+)
2VDC Outputs
PTM-8150
E
IGHT
C
HANNEL
P
OWER
A
MPLIFIER
-
OUTPUT
2-16
Ω
+
CH
1
INPUT
47K
Ω
-
OUTPUT
2-16
Ω
+
CH
2
INPUT
47K
Ω
CH
5
+
OUTPUT
2-16
Ω
-
INPUT
47K
Ω
-
OUTPUT
2-16
Ω
+
CH
3
INPUT
47K
Ω
-
OUTPUT
2-16
Ω
+
CH
4
INPUT
47K
Ω
1500W POWER
115 V~/60 Hz • 230 V~/50 Hz
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
ATTENTION!
MADE IN U.S.A.
INPUT
47K Ω
CH
6
+
OUTPUT
2-16 Ω
-
INPUT
47K
Ω
CH
7
+
OUTPUT
2-16
Ω
-
INPUT
47K
Ω
CH
8
+
OUTPUT
2-16
Ω
-
CAUTION! DO NOT SHORT OUTPUTS!
CAUTION:
DISCONNECT SUPPLY
CORD BEFORE
SERVICING.
ATTENTION:
DEBRANCHER AVANT
LE DEPANNAGE.
REPLACE
WITH SAME
VALUE FUSE
10A S.B.~115V
5A S.B.~230V
WARNING!
RISK OF HAZARDOUS
ENERGY!
MAKE PROPER SPEAKER
CONNECTIONS.
VOLTAGE
SWITCH
230 V~
AVERTISSEMENT! ENERGIE
ELECTRIQUE DANGEREUSE! FAIRE
DES CONNEXIONS PROPRES POUR
L'HAUTPARLEUR. VOIR LA NOTICE
DE FONCTIONNEMENT.
115 V~
115 V
The PTM-8150 Eight Channel High Power Amplifier can be used to provide high power to zones 13-
16. Again use an ACC-3 to turn on the PTM-8150 when any of these four zones are turned on. On the P-16, use a small jumper wire to terminate together pins 2-5 and use a common ground (-).
1 2 3 4
-A+ -B+
ACC-3
ACC-3
PIN 1 (-)
PIN 2 (+)
- 15 -
Home Theater (or Recording) Set Up
When working with home theater preamplifiers, whether they are in the form of an AV receiver or separate preamplifier and amplifier, you can assign a Suite 16 zone output to the theater room. As such, the theater preamplifier can play the same components that are playing through the rest of the home. To do this, connect a zone’s line-level audio signal to your home theater preamp or receivers multi-room input (or Auxiliary input). Prior to making these connections, you will first need to set that zone’s preamplifier output to fixed. This will require pulling the P-16 module out slightly so that the Fixed/Variable jumper pins can be moved from the Variable position to the Fixed position. This same procedure is used when connecting a
Suite 16 zone output to a recording device which also will require a fixed line-level signal.
V
F
V
F
V
F
V
F
V
F
V
F
V
F
V
F
V
F
15 16
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
L
R
1 2 3 4 5 6 7 8
P-16
9 10 11 12 13 14 15 16
Zones 1- 6 & 7-12
Zones 1-6
In 6/12 TO PTM-1225/1260
In 4/10
In 3/9
In 1/7
In 2/8
P-16 • Preamplifier Module
Zones 13-16
+12VDC Output
Gnd
(-)
13
(+)
14
(+)
15
(+)
16
(+)
1
2
1
L
R
VIDEO INPUTS
3 5
4
2
6
L
3
R
7
8
4
VIDEO OUT
1 REC
PIN +/- CHAN
1 / 14 LT
2 / 15 CT
3 / 16
4 / 17
RT
SB
5 / 18 SL
6 / 19 SR
PIN +/-
7 / 20
8 / 21
9 /10/22
11 / 23
12 / 24
13 / 25
CHAN
SBL
SBR
SHLD
R.T.A
R.T.B
R.T.C
MULTI-PIN LFE SUM
0dB +10dB
8 CHANNEL DB-25 INPUT
MAIN REC 1
S-VIDEO INPUTS
2 3 4
2 OSD
L
SBL LS L
1
13
25 14
1
Y
PIN
POINTS
P
B/B-Y
COMPONENT VIDEO
P
R/R-Y
Y P
B/B-Y
3
O
UTPUT
2
C
Y
DIGITAL AUDIO
INPUTS
OPTICAL INPUTS
1
P
R
3
5
L
R
6 7
R
8 MAIN
AUDIO INPUTS
SBR RS R SUB
1 2 3 4 2 4
RECORD
OUT
L
R
ADA NET™
"Dolby", "Pro Logic", & the double-D
Symbol are trademarks of Dolby
Laboratories. All rights reserved.
Manufactured under license from Digital
Theater Systems, Inc. US Pat. No.
5,451,942, 5,956,764, 5,974,380,
5,978,762 and other worldwide patents issued and pending. "DTS", "DTS-ES
Extended Surround", and "Neo 6" are trademarks of Digital Theater Systems,
Inc. © 1996, 2000 Digital Theater
Systems, Inc. All rights reserved.
Manufactured under license from
Lucasfilm Ltd. U.S. patent numbers
5,043,970; 5,189,703; and/or 5,222,059.
European patent number 0323830.
Other U.S. and foreign patents pending.
Lucasfilm and THX are trademarks or registered trademarks of Lucasfilm Ltd.
Surround EX is a jointly developed technology of THX and Dolby
Laboratories, Inc., and is a trademark of
Dolby. Used under authorization.
DATA PORT
Serial Data
ADA Bus®
1 2 3 4
12VDC OUT
100mA Max Per
DC 1
1- 2+
DC 2
1- 2+
G
ND
I
N
12
C
INEMA
R
HAPSODY
M
ACH
II
OME
T
HEATER
C
ONTROLLER
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
ATTENTION!
RISQUE DE CHOC ELECTRIQUE.
NE PAS OUVRIR
MADE IN U.S.A.
WARNING! Risk Of Hazardous Energy! Make Proper
Connections.
AVERTISSEMENT! Energie Electrique Dangereuse!
Faire Des Connexions Propres Pour L'Hautparleur.
Voir La Notice De Fonctionnement.
CAUTION: Disconnect Supply Cord Before
Servicing.
ATTENTION: Debrancher Avant Le Depannage.
Voltage
Selector &
Safety Fuse
On This Side
115 V
115V 230V
AC OUTPUT AC INPUT
10A~ Max Switched 115V~60Hz/230V~50Hz
Use Same
Value Fuse
115V~1AS.B.
230V~.5AS.B.
L
R
1 2 3 4 5 6 7 8 9
P-16
10 11 12 13 14 15 16
Zones 1- 6 & 7-12
Zones 1-6
In 6/12 TO PTM-1225/1260
In 5/11
In 4/10
In 3/9
Gnd
In 1/7
In 2/8
P-16 • Preamplifier Module
Zones 13-16
+12VDC Output
Gnd
(-)
13
(+)
14
(+)
15
(+)
16
(+)
7-12
25/1260
Gnd n 1/7 n 2/8
P-16 • Preamplifier Module
Zones 13-16
+12VDC Output
Gnd
(-)
13
(+)
14
(+)
15
(+)
16
(+) puts
CAUTION! DO NOT SHORT OUTPUTS!
Manufactured under license from Lucasfilm Ltd.
Lucasfilm and THX are registered trademarks of Lucasfilm Ltd.
OUTPUT 4-16
Ω
+
INPUT
47K Ω
CH 1
CH 4
INPUT
47K Ω
OUTPUT 4-16
+ -
Ω
OUTPUT 4-16
Ω
+
CH 2
INPUT
47K Ω
WARNING!
RISK OF HAZARDOUS
ENERGY!
MAKE PROPER SPEAKER
CONNECTIONS.
INPUT
47K Ω
CH 5
OUTPUT 4-16
Ω
+ -
AVERTISSEMENT! ENERGIE
ELECTRIQUE DANGEREUSE! FAIRE
DES CONNEXIONS PROPRES POUR
L'HAUTPARLEUR. VOIR LA NOTICE
DE FONCTIONNEMENT.
OUTPUT 4-16
Ω
+
CH 3
INPUT
47K Ω
INPUT
47K Ω
CH 6
OUTPUT 4-16
Ω
+ -
CAUTION: DISCONNECT SUPPLY CORD
BEFORE SERVICING.
ATTENTION: DEBRANCHER AVANT
LE DEPANNAGE.
PTM-6150 P
OWER
A
MP
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
ATTENTION!
RISQUE DE CHOC ELECTRIQUE.
NE PAS OUVRIR
MADE IN U.S.A.
VOLTAGE
SWITCH
115 V - 230 V
REPLACE
WITH SAME
VALUE FUSE
10A S.B.
POWER
115 V - 230 V
50 Hz - 60 Hz
In the example above, zone 16 is set to fixed audio output and is sending signal to the Cinema Rhapsody Mach
II on input 8 (Multi-Room). For zones 13, 14, and 15, a
PTM-6150 Six Channel Amplifier is used in conjunction with an ACC-3. Here, the low voltage triggers for these zones are combined to trigger the ACC-3 when any of these zones is turned on.
1 2 3 4
-A+ -B+
ACC-3
ACC-3
PIN 1 (-)
PIN 2 (+)
- 16 -
Amp Trigger Jumping on 9-Pin D Connectors
When more than just a few zones require greater power, several ADA amplifiers options exist including the PTM-6150 (6 x 150W/Ch @ 8 Ω, 250W/Ch @ 4Ω, stable to 2Ω), PTM-8150 (8 x
150W/Ch @ 8 Ω, 250W/Ch @ 4Ω, stable to 2Ω), and PTM-1260 (operating in bridged mode -
6 x 175W/Ch @ 8 Ω, 350W/Ch @ 4Ω, stable to 4Ω). While the PTM-1260 has zoned triggers built-in, the PTM-6150 and PTM-8150 will require an ACC-3 to turn them on. Again, one can combine zone triggers together to engage a single amplifier, even if it is powering more than one zone.
There are two ways one can combine triggers together. ADA suggests using the DB-9 9-Pin
Termination Block but you can also cut and splice a ribbon cable. If you choose to use the
DB-9, you will need one for every P-16 D connector you will be triggering from and another for every PTM-1260 that is running in bridged mode. When doing so, remember to switch the appropriate channels to bridged mode on the back of the PTM-1260 and that in this mode, the amplifier is only stable to 4
Ω. The PTM-1260 can be bridged from 12, to 10, 8, or 6 channels.
The diagram below shows a PTM-
6150 with Ch. 1 & 2 = zone 1, Ch. 3 &
4 = zone 2, and Ch. 5 & 6 = zone 3.
Male Connector
Plugs Into P-16 DB-9 Jack
(on DB-9 or Ribbon Cable)
Pin 4/Zone 6
Pin 1/Gnd
Pin 6/Zone 1
Pin 7/Zone 2
Pin 5/Zone 5
Pin 9/Zone 4
Pin 8/Zone 3
L
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Zones 1- 6 & 7-12
Zones 1-6
In 6/12 TO PTM-1225/1260
In 5/11
In 4/10
In 3/9
Gnd
In 1/7
In 2/8
P-16 • Preamplifier Module
Zones 13-16
+12VDC Output
Gnd
(-)
13
(+)
14
(+)
15
(+)
16
(+)
ACC-3
PIN 1 (-)
PIN 2 (+)
P-16
R
Zones 7-12
+12VDC Outputs
1 2 3 4
-A+ -B+
ACC-3
CAUTION! DO NOT SHORT OUTPUTS!
Manufactured under license from Lucasfilm Ltd.
Lucasfilm and THX are registered trademarks of Lucasfilm Ltd.
OUTPUT 4-16 Ω
+
INPUT
47K
Ω
CH 1
CH 4
INPUT
47K Ω
OUTPUT 4-16
Ω
+ -
OUTPUT 4-16 Ω
+
CH 2
INPUT
47K Ω
WARNING!
RISK OF HAZARDOUS
ENERGY!
MAKE PROPER SPEAKER
CONNECTIONS.
INPUT
47K
Ω
CH 5
OUTPUT 4-16
Ω
+ -
AVERTISSEMENT! ENERGIE
ELECTRIQUE DANGEREUSE! FAIRE
DES CONNEXIONS PROPRES POUR
L'HAUTPARLEUR. VOIR LA NOTICE
DE FONCTIONNEMENT.
OUTPUT 4-16 Ω
+
CH 3
INPUT
47K Ω
INPUT
47K
Ω
CH 6
OUTPUT 4-16
Ω
+ -
CAUTION: DISCONNECT SUPPLY CORD
BEFORE SERVICING.
ATTENTION: DEBRANCHER AVANT
LE DEPANNAGE.
PTM-6150 P
OWER
A
MP
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
ATTENTION!
RISQUE DE CHOC ELECTRIQUE.
NE PAS OUVRIR
MADE IN U.S.A.
VOLTAGE
SWITCH
115 V - 230 V
REPLACE
WITH SAME
VALUE FUSE
10A S.B.
POWER
115 V - 230 V
50 Hz - 60 Hz
The diagram below shows a PTM-1260 in bridged mode for all channels such that Ch. 1 & 2 = zone 1, Ch. 3 & 4 = zone 2, and Ch. 5 & 6 = zone 3.
L
1
R
2 3 4 5 6 7 8
P-16
9
Male Connector
Plugs Into P-16 DB-9 Jack
(on DB-9 or Ribbon Cable)
Pin 1/Gnd
Pin 6/Zone 1
Pin 7/Zone 2
Pin 4/Zone 6
Pin 5/Zone 5
Pin 9/Zone 4
Pin 8/Zone 3
10 11 12 13 14 15 16
Zones 1- 6 & 7-12
Zones 1-6
In 6/12 TO PTM-1225/1260
In 5/11
In 4/10
In 3/9
Gnd
In 1/7
In 2/8
P-16 • Preamplifier Module
Zones 13-16
+12VDC Output
Gnd
(-)
13
(+)
14
(+)
15
(+)
16
(+)
Set To
Bridged
MP
+
L
S TEREO
R
OM
B
RIDGED
L
S TEREO
R
B RIDGED
COM
+ -
-
Z ONE 1
L
EFT
/ 1
+
COM
-
B
RIDGED
/ 4
+
+
+
B
RIDGED
/ 1
-
COM
-
R
IGHT
/ 7
EFT
/ 8
Z
ONE
4
WARNING! RISK OF HAZARDOUS
ENERGY! MAKE PROPER SPEAKER
CONNECTIONS.
-
R
IGHT
/ 2
+
B
RIDGED
R
S TEREO
L
COM
PTM-1260 P
OWER
A
MP
L
-
Z ONE 2
L
EFT
/ 3
+
S TEREO
-
R
IGHT
/ 4
+
R
+
B RIDGED
COM
COM
B
-
RIDGED
/ 5
+
+ -
B
RIDGED
/ 2
COM
B
RIDGED
COM
R
+ -
S TEREO
L
R
IGHT
/ 9 L
EFT
/ 10
Z
ONE
5
AVERTISSEMENT! ENERGIE ELECTRIQUE DANGEREUSE!
FAIRE DES CONNEXIONS PROPRES POUR
L'HAUTPARLEUR. VOIR LA NOTICE DE FONCTIONNEMENT.
+
L
S TEREO
R
COM
B RIDGED
R
IGHT
/ 11
CAUTION:
ATTENTION:
-
-
-
COM
B
RIDGED
+
Z ONE 3
EFT
/ 5
+
/ 6
+
B
RIDGED
/ 3
COM
-
-
R
IGHT
/ 6
B
RIDGED
+
COM
R
+ -
S TEREO
L
L
EFT
/ 12
Z
ONE
6
DISCONNECT SUPPLY CORD BEFORE SERVICING.
DEBRANCHER AV LE DEPANNAGE.
STANDBY
REPLACE WITH SAME VALUE FUSE
2/10A S.B.~115V
1/10A S.B.~230V
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
ATTENTION!
RISQUE DE CHOC ELECTRIQUE.
NE PAS OUVRIR
MADE IN U.S.A.
MAIN
REPLACE
WITH SAME
VALUE FUSE
A LL Z
DC T
RIGGER
1 2
(-) (+)
9-P IN D C ONNECTOR
O
PERATES
D
ELTA
-88
Z ONE T RIGGERS
1-6 O
NLY
T
RIGGER
S
WITCH
VOLTAGE
SWITCH
115 V~ /
230 V~
B YPASS E XTERNAL
POWER
115 V~ / 230 V~
50 Hz / 60 Hz
VOLTAGE SWITCH
115 V~ / 230 V~
10A S.B.~115V
5A S.B.~230V
1500W
- 17 -
Pin 1/Gnd
Pin 6/Brdg 1
Pin 7/Brdg 2
Pin 4/Brdg 6
Pin 5/Brdg 5
Pin 9/Brdg 4
Pin 8/Brdg 3
Male Connector
Plugs Into PTM-1260 DB-9 Jack
(on DB-9 or Ribbon Cable)
V-16 Video Switching Module
The V-16 Video Switching Module expands Suite 16’s distribution capabilities to include composite video as well as audio routing. Much like the P-16 Modules, the V-16 can be used in multiples for up to 96 zones of video switching (up to six V-16 Modules).
1
2
3
4
5
6
7
VIDEO INPUTS
9 11
8 10 12
13
14
15
16
1
V16
2
3
4
5
6
7
VIDEO OUTPUTS
9 11
8 10 12
13
14
15
16
Out 1-8
Output Triggers
Out 6/14
Out 5/13
Out 4/12
Out 3/11
Out 7/15
Out 8/16
Gnd
Out 1/9
Out 2/10
V-16 • Video I/O Module
Programmed Video
Input Triggers
5-24V AC•DC
Gnd
(-)
1
(+)
2
(+)
3
(+)
4
(+)
Out 9-16
+12VDC Outputs
Input Triggers
Video Inputs
The V-16 features sixteen video inputs per V-16 Module. When using multiple V-16 Modules, one must Y split the composite video signal of a source component to distribute it to more than one V-16. The V-16 features Hi-Z termination making video splitting possible without signal loss.
Video Outputs
The V-16 features sixteen video outputs per V-16 Module. These can be connected to TVs, monitors, plasma TVs, projectors, video touch-screen controls, etc.
Video/Audio Tracking
The V-16 can be programmed in software such that any of its sixteen inputs tracks the corresponding audio input. As such, when either a DSS, DVD, VCR, or computer game input is selected, the appropriate video signal can automatically be routed to the room’s TV or other video display. Alternately, video inputs can be selected independently of audio signals, ideal when one might want to listen to music while viewing a stock-ticker or sporting event.
Video Options
Because the V-16 has sixteen video inputs and sixteen video outputs, it may have more connections than one might think can be used in a single system. For example, one might only have 10 audio/video sources, 6 audio only sources, and only 8 rooms with a video display. That would leave six video inputs and eight video outputs unused. This may leave open the door to include up to 6 closed-circuit TV cameras which could be switched to any of the 8
TVs. On the output side, the eight unused video outputs could be used to drive video-capable touch screen controls. This makes the V-16 not just an ideal video switcher for entertainment purposes, but also ideal for integration of security cameras and touch screen preview video displays.
Video Output Triggers
The V-16 features two 9-pin “D” type connectors (non-RS-232) that engage a +12VDC signal when the corresponding video output is selected. The top connector includes a common ground pin and the eight other pins correspond to video outputs 1-8. The bottom connector also features a common ground pin with the remaining eight pins corresponding to video outputs 9-16. These triggers can be used to trigger video monitors or other source devices when a video output is selected.
Out 1-8
Output Triggers
Out 6/14
Out 5/13
Out 4/12
Out 3/11
Out 7/15
Out 8/16
Gnd
Out 1/9
Out 2/10
V-1
Pro
I
5
Gnd
(-) ut 9-16
+12VDC Outputs
Inp
- 18 -
Programmed Video Triggers
The V-16 also features five programmed triggers. The removable
5-pin screw terminal connector features ground (-) on pin 1, and 3-
24V AC or DC input voltage sensing triggers on pins 2-5. These are used to engage multiple switching functions in that are programmed by the installer. All four triggers can also be serially engaged. The fifth trigger can only be engaged via serial control.
8/16
1/9
2/10
V-16 • Video I/O Module
Programmed Video
Input Triggers
5-24V AC•DC
Gnd
(-)
1
(+)
2
(+)
3
(+)
4
(+)
Interactive Use of Triggers
The video triggers can engage more than just a single video input when a trigger is activated.
s
Input Triggers
For example, the main entrance of the home has the door bell set to engage an audio and video trigger. The audio trigger is set to line-sensing using the door chime mechanism as the audio trigger source. When the door bell is pressed, the chime will play through selected rooms using the audio sensing paging input. The main entrance also has two closed circuit
TV cameras monitoring the doorway. These input into the V-16 module on inputs 14 and 16
(completely arbitrary inputs). When the door bell is pressed, not only will the chime play through the system, but also the video cameras can be displayed. During setup, you can determine which video outputs follow any one of the triggers. If an output is dedicated to a video capable touch screen and that touch screen is set to monitor Trigger 1, then when the door bell is pressed, that touch screen will get the cameras at the front door.
Cycle Count & Dwell Time
In the case where more than one camera is set to a specific trigger, the V-16 features both a cycle count setting (1-99 cycles) and a dwell time setting (1-60 seconds). In the example above, when the door bell is pressed, the touch screen will display both camera 1 and camera
2 where you can determine how long each camera is held in frame and how often the cycle repeats itself. Cycle count and dwell time are global settings affecting all four triggers. All sixteen inputs can be set to follow a trigger if desired. When only a single camera is set to a trigger, its image remains steady even if numerous cycles are employed due to the requirements of other triggers.
L
R
L
R
1
2
1
1
3
4
2
2
5
6
3
3
8
4
4
10
5
5
7
VIDEO INPUTS
9 11
12
6
6
13
14
7
7
15
16
8
8
A-16
P-16
1
V16
2
EXPANSION PORTS
9
9
3
4
10
10
5
6
11
11
7
8
12
12
9
10
13
13
11
12
14
14
13
14
15
15
15
16
16 In 1-8
Input Triggers
In 6/14
In 5/13
In 7/15 In 8/16
Gnd
A-16 • Audio Input Module
Balanced
Audio Page
Input (600 Ω)
1
Com
2
(+)
3
(-)
Trigger
5-24V
AC•DC
4
(+)
5
(-)
16
In 9-16
+12VDC Outputs Paging Input/Trigger
Zones 1- 6 & 7-12
Zones 1-6
In 6/12 TO PTM-1225/1260
In 5/11 Gnd
In 2/8
P-16 • Preamplifier Module
Zones 13-16
+12VDC Output
Gnd
(-)
13
(+)
14
(+)
15
(+)
16
(+)
1/2 ASB
115V~
1/4 ASB
230V~
1 Gnd
2 Fdbk
4 +V
ADA Bus®
230V
3 Cntrl
115V
115 V
Zones 7-12
+12VDC Outputs
Out 1-8
Output Triggers
Out 6/14
Out 5/13
Out 4/12
Out 3/11
Out 7/15 Out 8/16
Gnd
Out 1/9
Out 2/10
V-16 • Video I/O Module
Programmed Video
Input Triggers
Gnd
(-)
5-24V AC•DC
1
(+)
2
(+)
3
(+)
4
(+)
Switch
AC
(10A)
Out 9-16
+12VDC Outputs
Input Triggers
Main
AC
Input
Network Control I/O
WARNING! Risk Of Hazardous Energy!
Make Proper Connections.
AVERTISSEMENT! Energie Electrique
Dangereuse!
Faire Des Connexions Propres
Pour L'Hautparleur.
Voir La Notice De Fonctionnement.
CAUTION: Disconnect Supply
Cord Before Servicing.
ATTENTION: Debrancher
Avant Le Depannage.
115V~/60Hz • 230V~/50Hz
500 WATTS MAX
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
ATTENTION!
RISQUE DE CHOC ELECTRIQUE.
NE PAS OUVRIR
MADE IN U.S.A.
AVP-16 MR Controller
CAM 1
CAM 2
Door Bell
Chime
6
In 6/14
In 5/13
In 4/12
In 3/11
In 7/15
In 8/16
Gnd
In 1/9
In 2/10
A-16 • Audio Input Module
Balanced
Audio Page
Input (600
Ω)
1
Com
2
(+)
3
(-)
Trigger
5-24V
AC•DC
4
(+)
5
(-)
G
2 Fd
4 +V
ADA Bus®
230V
3 Cn
6
In 9-16
+12VDC Outputs
Paging Input/Trigger
Zones 1- 6 & 7-12
Zones 1-6
115V
In 6/12 TO PTM-1225/1260
In 5/11 Gnd
In 2/8
P-16 • Preamplifier Module
Zones 13-16
+12VDC Output
Gnd
(-)
13
(+)
14
(+)
15
(+)
16
(+)
1/2 ASB
115V~
1/4 ASB
230V~
115 V
Out 1-8
Output Triggers
Out 6/14
Out 5/13
Out 4/12
Out 3/11
Out 7/15
Out 8/16
Gnd
Out 1/9
Out 2/10
V-16 • Video I/O Module
Programmed Video
Input Triggers
Gnd
5-24V AC•DC
1 2 3
(-) (+) (+) (+)
4
(+)
Switch
AC
(10A)
Out 9-16
+12VDC Outputs
Input Triggers
Main
AC
Input
Door Bell
120VAC
16-24V
Transformer
Chime
Speaker
Audio Out
(Line-Level)
If chime has no audio output, create line level using resistors across the chime speaker.
- 19 -
AVP-16 Baud Rate, Zone, & Paging Settings
The AVP-16 front panel is remarkably void of clutter. In addition to the main power switch, the front panel RS-232 I/O, there is only a smoked plexiglass plate through which several LEDs are visible. During setup, this plate may need to be removed to access options for the A-16,
P-16 or V-16 modules.
POWER
AVP-16
RS-232
AVP-16 Plexiglass Plate Removal
There are four screws that secure the front panel plexiglass plate. To remove the plate, simply remove these four screws.
0
POWER
AVP-16
RS-232
0
A-16 Module Front Panel Setup
The A-16 Audio Input module features twenty LEDs which indicate the presence of voltage
(power), which inputs are active (1-16), and whether the audio trigger is engaged. The diagram below details these LEDs and also shows the position of three trim pots.
COMPRESSION
SLOPE
INPUT
LEVEL
AUDIO
TRIGGER
ACTIVE AUDIO INPUTS (1-16)
+V -V VD 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
TRIGGER
LEVEL
POWER
SUPPLY
+/-V = ANALOG VOLTAGE
VD = DIGITAL VOLTAGE
- 20 -
The compression slope trim pot is used to compress the paging audio input signal. This feature will prevent an input signal that is too high from being broadcast at that level. While each room has its own paging volume level to prevent speaker overdrive, the compression slope adjustment is used to prevent the input signal from being distorted.
The input level adjustment trim pot is used to determine the level of the audio input signal.
With this adjustment, low level signals can be raised or signals that are too hot can be lowered.
The trigger level trim pot is used to adjust the sensitivity of the audio input trigger. There are a total of eight paging triggers. Six of these are serially controlled, one is a voltage trigger, and one trigger is audio sensing. This trim pot is used to set this trigger such that it engages and disengages appropriately.
P-16 Module Front Panel Setup
The P-16 Preamplifier module features twenty-two LEDs which indicate data transmission and reception, the presence of voltage (power), which zones are active (1-16), and whether the system is on. The diagram below details these LEDs and also
RX TX MAIN
ON
ACTIVE PREAMPLIFIER ZONES (1-16) shows the position of the address selector.
0
+V -V VD 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
The address selector sets the address of the P-16 module since as many as six
P-16s can be used for
ADDRESS
SWITCH
POWER
SUPPLY
+/-V = ANALOG VOLTAGE
VD = DIGITAL VOLTAGE up to 96 zones. Address “0” is the default address for zones 1-16 operating at a baud rate of 19200.
V-16 Module Front Panel Setup
The V-16 Video Switching module features twenty-two LEDs which indicate data transmission and reception, the presence of voltage (power), which outputs are active (1-16), and whether the system is on. The diagram below details these LEDs and also shows the position of the address selector.
RX TX
0
MAIN
ON
ACTIVE VIDEO ZONES (1-16)
+V -V VD 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
The address selector sets the address of the
V-16 module since as many as six V-16s can
ADDRESS
SWITCH
POWER
SUPPLY
+/-V = ANALOG VOLTAGE be used for up to 96
VD = DIGITAL VOLTAGE zones. Address “0” is the default address for zones 1-16 operating at a baud rate of 19200.
Dial Address 0 1 2 3 4 5 6 7 8 9 10 (A) 11 (B) 12 (C) 13 (D) 14 (E) 15 (F)
P-16 Zones 1 - 1 6 1 7 - 3 2 3 3 - 4 8 4 9 - 6 4 6 1 - 8 0 8 1 - 9 6 N/A N/A 1 - 1 6 1 7 - 3 2 3 3 - 4 8 4 9 - 6 4 6 1 - 8 0 8 1 - 9 6 N/A N/A
V-16 Zones
1 - 1 6 1 7 - 3 2 3 3 - 4 8 4 9 - 6 4 6 1 - 8 0 8 1 - 9 6 NF 1-16 NF 17-32 1 - 1 6 1 7 - 3 2 3 3 - 4 8 4 9 - 6 4 6 1 - 8 0 8 1 - 9 6 NF 1-16 NF 17-32
(NF=No Feedback)
Baud Rate 1 9 2 0 0 1 9 2 0 0 1 9 2 0 0 1 9 2 0 0 1 9 2 0 0 1 9 2 0 0 1 9 2 0 0 1 9 2 0 0 1 2 0 0 1 2 0 0 1 2 0 0 1 2 0 0 1 2 0 0 1 2 0 0 1 2 0 0 1 2 0 0
- 21 -
AVP-16 Configuration Options
The AVP-16 is the Suite 16 chassis that can house up to three cards. As both the A-16, P-16, and V-16 are designed to be interchangeable, here are some options regarding configuration of the primary AVP-16.
Basic Setup - One A-16 and One P-16
This configuration is the most basic of all Suite 16 options in which 16 audio components are routed to 16 audio zones.
L
R
L
R
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
A-16
P-16
9
9
10
10
11
11
12
12
13
13
14
14
15
15
16 In 1-8
Input Triggers
In 6/14
In 5/13
In 7/15
In 8/16
Gnd
A-16 • Audio Input Module
Balanced
Audio Page
Input (600
Ω)
1
Com
2
(+)
3
(-)
Trigger
5-24V
AC•DC
4
(+)
5
(-)
1 Gnd
2 Fdbk
4 +V
ADA Bus®
230V
3 Cntrl
16
In 9-16
+12VDC Outputs
Paging Input/Trigger
Zones 1- 6 & 7-12
Zones 1-6
In 5/11
In 4/10
In 3/9
Gnd
In 1/7
In 2/8
P-16 • Preamplifier Module
Zones 13-16
+12VDC Output
Gnd
(-)
13
(+)
14
(+)
15
(+)
16
(+)
115V
115 V
1/2 ASB
115V~
1/4 ASB
230V~
Switch
AC
(10A)
Network Control I/O
WARNING! Risk Of Hazardous Energy!
Make Proper Connections.
AVERTISSEMENT! Energie Electrique
Dangereuse!
Faire Des Connexions Propres
Pour L'Hautparleur.
Voir La Notice De Fonctionnement.
CAUTION: Disconnect Supply
Cord Before Servicing.
ATTENTION: Debrancher
Avant Le Depannage.
115V~/60Hz • 230V~/50Hz
500 WATTS MAX
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
ATTENTION!
RISQUE DE CHOC ELECTRIQUE.
NE PAS OUVRIR
MADE IN U.S.A.
Main
AC
Input
AVP-16 MR Controller
Double Audio Setup - One A-16 & Two P-16s
This configuration adds an additional 16 zones for a total of 16 audio components to 32 audio zones.
L
R
L
R
L
R
1
1
1
2
2
2
3
3
3
4
4
4
5
5
5
6
6
6
7
7
7
8
8
8
A-16
P-16
P-16
9
9
9
10
10
10
11
11
11
12
12
12
13
13
13
14
14
14
15
15
15
16 In 1-8
Input Triggers
In 5/13
In 4/12
In 3/11
In 7/15
In 1/9
In 2/10
A-16 • Audio Input Module
Balanced
Audio Page
Input (600
Ω)
1
Com
2
(+)
3
(-)
Trigger
5-24V
AC•DC
4
(+)
5
(-)
1 Gnd
2 Fdbk
3 Cntrl
4 +V
ADA Bus®
16
In 9-16
+12VDC Outputs
Paging Input/Trigger
Zones 1- 6 & 7-12
Zones 1-6
In 6/12 TO PTM-1225/1260
In 5/11 Gnd
In 2/8
P-16 • Preamplifier Module
Zones 13-16
+12VDC Output
Gnd
(-)
13
(+)
14
(+)
15
(+)
16
(+)
230V
115V
115 V
1/2 ASB
115V~
1/4 ASB
230V~
Network Control I/O
16
Zones 1- 6 & 7-12
Zones 1-6
In 6/12 TO PTM-1225/1260
In 4/10
In 3/9
In 1/7
In 2/8
P-16 • Preamplifier Module
Zones 13-16
+12VDC Output
Gnd
(-)
13
(+)
14
(+)
15
(+)
16
(+)
Switch
AC
(10A)
Main
AC
Input
WARNING! Risk Of Hazardous Energy!
Make Proper Connections.
AVERTISSEMENT! Energie Electrique
Dangereuse!
Faire Des Connexions Propres
Pour L'Hautparleur.
Voir La Notice De Fonctionnement.
CAUTION: Disconnect Supply
Cord Before Servicing.
ATTENTION: Debrancher
Avant Le Depannage.
115V~/60Hz • 230V~/50Hz
500 WATTS MAX
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
ATTENTION!
RISQUE DE CHOC ELECTRIQUE.
NE PAS OUVRIR
MADE IN U.S.A.
AVP-16 MR Controller
Basic Video Setup - One A-16, One P-16, and One V-16
This configuration adds video to the basic 16 audio sources to 16 zone configuration. Because the video card can have outputs either track or not track the 16 audio inputs, one can treat the 16 video sources as additional inputs and outputs. For example, out of the 16 audio sources, only 10 have a video signal. That would leave 6 video inputs available for non-audio video input devices such as cameras.
L
R
L
R
1
2
1
1
3
4
2
2
5
6
3
3
8
4
4
10
5
5
7
VIDEO INPUTS
9 11
12
6
6
13
14
7
7
15
16
8
8
A-16
P-16
1
V16
2
EXPANSION PORTS
9
9
3
4
10
10
5
6
11
11
7
8
12
12
9
10
13
13
11
12
14
14
13
14
15
15
15
16
16 In 1-8
Input Triggers
In 6/14
In 5/13
In 7/15
In 8/16
Gnd
A-16 • Audio Input Module
Balanced
Audio Page
Input (600
Ω)
1
Com
2
(+)
3
(-)
Trigger
5-24V
AC•DC
4
(+)
5
(-)
1 Gnd
2 Fdbk
4 +V
ADA Bus®
230V
3 Cntrl
16
In 9-16
+12VDC Outputs
Paging Input/Trigger
Zones 1- 6 & 7-12
Zones 1-6
In 6/12 TO PTM-1225/1260
In 4/10
In 3/9
In 1/7
In 2/8
P-16 • Preamplifier Module
Zones 13-16
+12VDC Output
Gnd
(-)
13
(+)
14
(+)
15
(+)
16
(+)
115V
115 V
1/2 ASB
115V~
1/4 ASB
230V~
Out 1-8
Output Triggers
Out 6/14
Out 5/13
Out 7/15 Out 8/16
Gnd
V-16 • Video I/O Module
Programmed Video
Input Triggers
5-24V AC•DC
Gnd
(+)
1
(+)
2
(+)
3
(+)
4
(+)
Switch
AC
(10A)
Out 9-16
+12VDC Outputs
Input Triggers
Main
AC
Input
Network Control I/O
WARNING! Risk Of Hazardous Energy!
Make Proper Connections.
AVERTISSEMENT! Energie Electrique
Dangereuse!
Faire Des Connexions Propres
Pour L'Hautparleur.
Voir La Notice De Fonctionnement.
CAUTION: Disconnect Supply
Cord Before Servicing.
ATTENTION: Debrancher
Avant Le Depannage.
115V~/60Hz • 230V~/50Hz
500 WATTS MAX
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
ATTENTION!
RISQUE DE CHOC ELECTRIQUE.
NE PAS OUVRIR
MADE IN U.S.A.
AVP-16 MR Controller
- 22 -
Matrix Switching - S-Video, Component, or RGBHV
For applications where an installation requires simultaneous switching of multiple discrete video signals, any Suite-16 V-16 Video Module may be set up as a slave card. This is useful for S-Video (Y & C), component video (Y, Cr, Cb), or HDTV video (RGBHV) switching. Furthermore, because of the Suite-16s value, configuration of a Suite 16 for matrix switching is extremely competitive.
As such, a single video switching command can activate switching of inputs for more than just a single V-16 module. For example, when using the S-Video configuration below, if video input 1 is selected in room 1, both video cards (one for C and one for Y), will switch together.
There are special technical issues that do come into play when switching multiple videos cards with a single command. In order for this feature to work, all V-16 modules need to be set to the same room address. As such, when a single command is issued, all cards will switch. The only problem that occurs when using standard V-16 addresses, stems from the feedback created by all cards. As each card switches, it will return conformation of the switch in the form of ASCII feedback. It is this feedback that may cause problems. As multiple cards respond, the feeback may get corrupted. To prevent this from occurring when using the AVP-
16 and V-16 modules as a matrix switcher, ADA has added two additional V-16 addresses that defeat feedback, preventing data corruption, while still permitting full control.
Changing of the V-16 Address
Located behind the removable plexiglass
RX TX panel on the front of the
AVP-16, each V-16
0 module has a rotary
DIP switch which sets
MAIN
ON
ACTIVE VIDEO ZONES (1-16)
+V -V VD 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 the address for the card. There are a total of sixteen address op-
ADDRESS
SWITCH
POWER
SUPPLY
+/-V = ANALOG VOLTAGE tions. Address 0 refers VD = DIGITAL VOLTAGE to rooms 1-16 for systems operating at 19200. Address 1 is for rooms 17-32 at the same baud rate. Alternately, address 9 is for rooms 1-16 for systems operating at 1200 baud while address 10 (sometimes noted as address A) is for rooms 17-32 at the same baud rate.
Dial Address 0 1 2 3 4 5
P-16 Zones 1 - 1 6 1 7 - 3 2 3 3 - 4 8 4 9 - 6 4 6 1 - 8 0 8 1 - 9 6
6
N/A
7
N/A
8 9
1 - 1 6 1 7 - 3 2
10 (A) 11
3 3 - 4 8
(B) 12 (C) 13 (D) 14 (E) 15 (F)
4 9 - 6 4 6 1 - 8 0 8 1 - 9 6 N/A N/A
V-16 Zones
(NF=No Feedback)
1 - 1 6 1 7 - 3 2 3 3 - 4 8 4 9 - 6 4 6 1 - 8 0 8 1 - 9 6 NF 1-16 NF 17-32 1 - 1 6 1 7 - 3 2
Baud Rate 1 9 2 0 0 1 9 2 0 0 1 9 2 0 0 1 9 2 0 0 1 9 2 0 0 1 9 2 0 0 1 9 2 0 0 1 9 2 0 0 1 2 0 0 1 2 0 0
3 3 - 4 8
1 2 0 0
4 9 - 6 4
1 2 0 0
6 1 - 8 0
1 2 0 0
8 1 - 9 6
1 2 0 0
NF 1-16 NF 17-32
1 2 0 0 1 2 0 0
There are V-16 Video Module addresses that are specifically designed not to provide feeback.
Address 6 refers to rooms 1-16 at 19200 without feedback and Address 7 refers to rooms 17-
32 at 19200, also without feedback. For 1200 baud systems without feedback, address 14
(also known as address E) refers to rooms 1-16 while address 15 (also known as address F) refers to rooms 17-32. These addresses are to be used on the second, third, fourth, and fifth
V-16 modules. The first module uses the standard address. Here it is important that all room and baud rate groups match.
- 23 -
If you have a Suite-16 for 16 rooms that is switching composite video and you have a component video switching matrix in a separate AVP-16 chassis, then you might opt to use the room group address of 17-32 for the matrix switcher. As such, you could connect the Suite-16 audio video system running 16 zones with composite video (addressed for rooms 1-16) and the 16 x 16 component video matrix Suite 16 (set to room address 17-32) on the same ADA
Bus network without conflict.
In the event, you have 17 or more rooms on a Suite-16 setup for audio and video switching, you will need to communicate to the Suite-16 setup for component video switching, through a separate com port. Here you could opt to run the matrix switcher on any of the two room group addresses, as this switcher is not going to be connected directly to the Suite-16 audio video system.
S-Video Switching
This configuration uses a single AVP-16 chassis outfitted with two V-16 modules.
One module is connected to up to 16 S-Video “Y” outputs.
The second module connects the “C” S-Video outputs. The
1
2
1
2
3
4
3
4
5
6
5
6
7
8
7
VIDEO INPUTS
9 11
8
VIDEO INPUTS
9
10
10
11
12
12
13
14
13
14
15
16
15
16
1
V16
2
1
V16
2
EXPANSION PORTS
3
4
3
4
5
6
5
6
7
8
7
8
9
10
9
10
11
12
11
12
13
14
13
14
15
16
15
16
Out 1-8
Output Triggers
Out 6/14
Out 5/13
Out 7/15
Out 8/16
Gnd
V-16 Video I/O Module
Programmed Video
Input Triggers
5-24V AC DC
Gnd
(-)
1
(+)
2
(+)
3
(+)
4
(+)
Out 9-16
+12VDC Outputs
Out 1-8
Output Triggers
Input Triggers
Out 6/14
Out 5/13
Out 4/12
Out 3/11
Out 7/15
Out 8/16
Gnd
Out 1/9
Out 2/10
V-16 Video I/O Module
Programmed Video
Input Triggers
5-24V AC DC
Gnd
(-)
1
(+)
2
(+)
3
(+)
4
(+)
1/2 ASB
115V~
1/4 ASB
230V~
1 Gnd
Network Control I/O
2 Fdbk
3 Cntrl
4 +V
ADA Busfi
230V
115V
115 V
Out 9-16
+12VDC Outputs Input Triggers Switch
AC
(10A)
WARNING! Risk Of Hazardous Energy!
Make Proper Connections.
AVERTISSEMENT! Energie Electrique
Dangereuse!
Faire Des Connexions Propres
Pour L’Hautparleur.
Voir La Notice De Fonctionnement.
CAUTION: Disconnect Supply
Cord Before Servicing.
ATTENTION: Debrancher
Avant Le Depannage.
115V~/60Hz 230V~/50Hz
500 WATTS MAX
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
ATTENTION!
RISQUE DE CHOC ELECTRIQUE.
NE PAS OUVRIR
MADE IN U.S.A.
Main
AC
Input
AVP-16 MR Controller end result is a 16 x 16 S-Video switcher. Here the first card needs to be set to the 0 address while the second unit is set to address 6. You can also uses addresses 1 and 7 respectively.
For 1200 baud systems, addresses 8 and 14 could be used or addresses 9 and 15.
Component Video Switching
This configuration uses a single AVP-16 chassis outfitted with three V-16 modules.
One module is connected to up to 16 “Y” outputs. The
1
2
1
3
4
3
5
6
5
7
8
7
VIDEO INPUTS
9
10
VIDEO INPUTS
9
11
12
11
13
14
13
15
16
15
1
V16
2
1
V16
2
3
4
3
5
6
5
7
8
7
9
10
9
11
12
11
13
14
13
15
16
15
Out 1-8
Output Triggers
Out 6/14
Out 5/13
Out 7/15 Out 8/16
Gnd
V-16 Video I/O Module
Programmed Video
Input Triggers
5-24V AC DC
Gnd
(-)
1
(+)
2
(+)
3
(+)
4
(+)
Out 9-16
+12VDC Outputs
Out 1-8
Output Triggers
Input Triggers
Out 6/14
Out 5/13
Out 4/12
Out 3/11
Out 7/15
Out 8/16
Gnd
Out 1/9
Out 2/10
V-16 Video I/O Module
Programmed Video
Input Triggers
5-24V AC DC
Gnd
(-)
1
(+)
2
(+)
3
(+)
4
(+)
Out 9-16
+12VDC Outputs
Out 1-8
Output Triggers
Input Triggers
Out 6/14
Out 5/13
Out 4/12
Out 3/11
Out 7/15
Out 8/16
Gnd
Out 1/9
Out 2/10
V-16 Video I/O Module
Programmed Video
Input Triggers
5-24V AC DC
Gnd
(-)
1
(+)
2
(+)
3
(+)
4
(+)
1 Gnd
Network Control I/O
2 Fdbk
3 Cntrl
4 +V
ADA Busfi
230V
115V
115 V
1/2 ASB
115V~
1/4 ASB
230V~
2
1
4
3
6
5
8
7
10
VIDEO INPUTS
9
12
11
14
13
16
15 1
V16
2
4
3
6
5
8
7
10
9
12
11
14
13
16
15
Switch
AC
(10A)
WARNING! Risk Of Hazardous Energy!
Make Proper Connections.
AVERTISSEMENT! Energie Electrique
Dangereuse!
Faire Des Connexions Propres
Pour L’Hautparleur.
Voir La Notice De Fonctionnement.
CAUTION: Disconnect Supply
Cord Before Servicing.
ATTENTION: Debrancher
Avant Le Depannage.
115V~/60Hz 230V~/50Hz
500 WATTS MAX
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
ATTENTION!
RISQUE DE CHOC ELECTRIQUE.
NE PAS OUVRIR
MADE IN U.S.A.
second module connects the 2 4 6 8 10 12 14 16 4 6 8 10 12 14 16
Out 9-16
+12VDC Outputs Input Triggers
Main
AC
Input
EXPANSION PORTS
AVP-16 MR Controller
“Cr” component outputs. The third card connects the “Cb” component outputs. The end result is a 16 x 16 component video switcher. Here the first card needs to be set to the 0 address while the second and third cards are set to address 6. You can also uses addresses 1 and 7 respectively. For 1200 baud systems, addresses 8 and 14 could be used or addresses 9 and 15.
RGBHV Video Switching
This configuration uses a two AVP-16 chassis outfitted with three V-16 modules in the first chassis and two in the second. One module is connected to up to 16 “R” outputs. The second module connects the “G” video outputs. The third card connects the “B” video outputs. In the second chassis, the first card is connect to the “H” video outputs and the second card is connected to the “V” video outputs. The end result is a 16 x 16 component video switcher.
Here the first card needs to be set to the 0 address while the second, third, fourth, and fifth cards are set to address 6. You can also uses addresses 1 and 7 respectively. For 1200 baud systems, addresses 8 and 14 could be used or addresses 9 and 15. An RGBHV switcher is a combination of the two diagrams above.
- 24 -
AVP-16 Slave-Unit Configuration Options
Slave Audio Setup - In addition to the first AVP-16, a 2nd chassis w/One P-16
This configuration is in addition to the primary AVP-16 and as such, does not require an A-16
Audio Input Module. This chassis adds 16 zones to the primary unit.
L
R
1 2 3 4 5 6 7 8 9
P-16
10 11 12 13 14 15 16
Zones 1- 6 & 7-12
Zones 1-6
In 6/12 TO PTM-1225/1260
In 5/11
In 4/10
In 3/9
Gnd
In 1/7
In 2/8
P-16 • Preamplifier Module
Zones 13-16
+12VDC Output
Gnd 13 14 15 16
(-) (+) (+) (+) (+)
Zones 7-12
+12VDC Outputs
1 Gnd
2 Fdbk
4 +V
ADA Bus®
230V
3 Cntrl
115V
115 V
1/2 ASB
115V~
1/4 ASB
230V~
Switch
AC
(10A)
Network Control I/O
WARNING! Risk Of Hazardous Energy!
Make Proper Connections.
AVERTISSEMENT! Energie Electrique
Dangereuse!
Faire Des Connexions Propres
Pour L'Hautparleur.
Voir La Notice De Fonctionnement.
CAUTION: Disconnect Supply
Cord Before Servicing.
ATTENTION: Debrancher
Avant Le Depannage.
115V~/60Hz • 230V~/50Hz
500 WATTS MAX
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
ATTENTION!
RISQUE DE CHOC ELECTRIQUE.
NE PAS OUVRIR
MADE IN U.S.A.
Main
AC
Input
AVP-16 MR Controller
Slave Audio Setup - In addition to the first AVP-16, a 2nd chassis w/ Two P-16s
This configuration adds 32 zones to those in the first chassis. If the first chassis houses two
P-16s and the second houses two P-16s, the zone count is 64.
L
R
1
L
1
R
2 3
2 3
4 5
4 5
6 7
6 7
8
P-16
9
8 9
P-16
10 11 12
10 11 12
13 14
13 14
15
15
16
Zones 1- 6 & 7-12
Zones 1-6
In 6/12 TO PTM-1225/1260
In 5/11
In 4/10
In 3/9
Gnd
In 1/7
In 2/8
P-16 • Preamplifier Module
Zones 13-16
+12VDC Output
Gnd
(-)
13
(+)
14
(+)
15
(+)
16
(+)
1 Gnd
2 Fdbk
4 +V
ADA Bus®
230V
3 Cntrl
Zones 7-12
+12VDC Outputs
16
Zones 1- 6 & 7-12
Zones 1-6
In 6/12 TO PTM-1225/1260
In 5/11
In 4/10
In 3/9
Gnd
In 1/7
In 2/8
P-16 • Preamplifier Module
Zones 13-16
+12VDC Output
Gnd
(-)
13
(+)
14
(+)
15
(+)
16
(+)
115V
115 V
1/2 ASB
115V~
1/4 ASB
230V~
Switch
AC
(10A)
Network Control I/O
WARNING! Risk Of Hazardous Energy!
Make Proper Connections.
AVERTISSEMENT! Energie Electrique
Dangereuse!
Faire Des Connexions Propres
Pour L'Hautparleur.
Voir La Notice De Fonctionnement.
CAUTION: Disconnect Supply
Cord Before Servicing.
ATTENTION: Debrancher
Avant Le Depannage.
115V~/60Hz • 230V~/50Hz
500 WATTS MAX
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
ATTENTION!
RISQUE DE CHOC ELECTRIQUE.
NE PAS OUVRIR
MADE IN U.S.A.
Main
AC
Input
AVP-16 MR Controller
Slave Audio Setup - In addition to the first AVP-16, a 2nd chassis w/ Three P-16s
This configuration adds 48 zones to those in the first chassis. If the first chassis houses two
P-16s and the second houses three P-16s, the zone count is 80.
L
1
R
L
1
R
L
R
1
2
2
2
3
3
3
4
4
4
5
5
5
6
6
6
7
7
7
8
P-16
8
P-16
9
8 9
P-16
9 10 11 12
10 11 12
10 11 12
13 14
13 14
13 14
15
15
15
16
Zones 1- 6 & 7-12
Zones 1-6
In 6/12 TO PTM-1225/1260
In 5/11
In 4/10
In 3/9
Gnd
In 1/7
In 2/8
P-16 • Preamplifier Module
Zones 13-16
+12VDC Output
Gnd
(-)
13
(+)
14
(+)
15
(+)
16
(+)
1 Gnd
2 Fdbk
3 Cntrl
4 +V
ADA Bus®
230V
16
Zones 1- 6 & 7-12
Zones 1-6
115V
In 6/12 TO PTM-1225/1260
In 5/11
In 4/10
In 3/9
Gnd
In 1/7
In 2/8
P-16 • Preamplifier Module
Zones 13-16
+12VDC Output
Gnd
(-)
13
(+)
14
(+)
15
(+)
16
(+)
1/2 ASB
115V~
1/4 ASB
230V~
115 V
16
Zones 1- 6 & 7-12
Zones 1-6
In 6/12 TO PTM-1225/1260
In 5/11
In 4/10
In 3/9
Gnd
In 1/7
In 2/8
P-16 • Preamplifier Module
Zones 13-16
+12VDC Output
Gnd
(-)
13
(+)
14
(+)
15
(+)
16
(+)
Switch
AC
(10A)
Zones 7-12
+12VDC Outputs
Main
AC
Input
Network Control I/O
WARNING! Risk Of Hazardous Energy!
Make Proper Connections.
AVERTISSEMENT! Energie Electrique
Dangereuse!
Faire Des Connexions Propres
Pour L'Hautparleur.
Voir La Notice De Fonctionnement.
CAUTION: Disconnect Supply
Cord Before Servicing.
ATTENTION: Debrancher
Avant Le Depannage.
115V~/60Hz • 230V~/50Hz
500 WATTS MAX
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
ATTENTION!
RISQUE DE CHOC ELECTRIQUE.
NE PAS OUVRIR
MADE IN U.S.A.
AVP-16 MR Controller
Slave Audio Setup - In addition to the first AVP-16, a second chassis w/ One P-16 &
One V-16
L
R
1
2
1
3
4
2
5
6
3
8
4
10
5
7
VIDEO INPUTS
9 11
12
6
13
14
7
15
16
8
P-16
1
V16
2
EXPANSION PORTS
9
3
4
10
5
6
11
7
8
12
9
10
13
11
12
14
13
14
15
15
16
16
Zones 1- 6 & 7-12
Zones 1-6
In 6/12 TO PTM-1225/1260
In 5/11
In 4/10
In 3/9
Gnd
In 1/7
In 2/8
P-16 • Preamplifier Module
Zones 13-16
+12VDC Output
Gnd
(-)
13
(+)
14
(+)
15
(+)
16
(+)
Zones 7-12
+12VDC Outputs
Output Triggers
Out 1-8
Out 6/14
Out 5/13
Out 4/12
Out 3/11
Out 7/15
Out 8/16
Gnd
Out 1/9
Out 2/10
V-16 • Video I/O Module
Programmed Video
Input Triggers
5-24V AC•DC
Gnd
(+)
1
(+)
2
(+)
3
(+)
4
(+)
1/2 ASB
115V~
1/4 ASB
230V~
1 Gnd
2 Fdbk
4 +V
ADA Bus®
230V
3 Cntrl
115V
115 V
Out 9-16
+12VDC Outputs Input Triggers
Switch
AC
(10A)
Network Control I/O
WARNING! Risk Of Hazardous Energy!
Make Proper Connections.
AVERTISSEMENT! Energie Electrique
Dangereuse!
Faire Des Connexions Propres
Pour L'Hautparleur.
Voir La Notice De Fonctionnement.
CAUTION: Disconnect Supply
Cord Before Servicing.
ATTENTION: Debrancher
Avant Le Depannage.
115V~/60Hz • 230V~/50Hz
500 WATTS MAX
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
ATTENTION!
RISQUE DE CHOC ELECTRIQUE.
NE PAS OUVRIR
MADE IN U.S.A.
Main
AC
Input
AVP-16 MR Controller
- 25 -
AVP-16 Slave-Unit Setup
When connecting more than one AVP-16 chassis together, the first chassis is considered the
Main Unit and all other chassis are considered Slave Units. The importance here is that the
Main Unit will become the one unit with a master turn-on switch. It will also be the chassis to house the A-16 module. Note, that audio is passed to Slave units via two 50 pin ribbon cables
(Ribbon-50). Also, the Slave Unit will derive power from the Main Units switched AC outlet using an IEC Female to IEC Male AC cord (IEC-MF). If additional AVP-16 Slave Units were employed, these would connect in line to the previous Slave Units switched AC outlet. Also, the Ribbon-50 cables would have additional connectors on the cable to permit connection of the other Slave Units.
L
R
1
L
R
1
L
R
1
2 3
2 3
2 3
4 5 6 7
4 5 6 7
4 5 6 7
8
8 9
P-16
8
A-16
P-16
9
9
10 11 12
10 11 12
10 11 12
13
13
13
14
14
14
15
15
15
16
In 1-8
Input Triggers
In 5/13
In 3/11
In 7/15
A-16 • Audio Input Module
Balanced
Audio Page
Input (600
Ω)
1
Com
2
(+)
3
(-)
Trigger
5-24V
AC•DC
4
(+)
5
(-)
16
In 9-16
+12VDC Outputs
Paging Input/Trigger
Zones 1- 6 & 7-12
Zones 1-6
In 6/12 TO PTM-1225/1260
In 5/11 Gnd
In 2/8
P-16 • Preamplifier Module
Zones 13-16
+12VDC Output
Gnd
(-)
13
(+)
14
(+)
15
(+)
16
(+)
1/2 ASB
115V~
1/4 ASB
230V~
4 +V
ADA Bus®
230V
3 Cntrl
115 V
1 Gnd
2 Fdbk
115V
16
Zones 1- 6 & 7-12
Zones 1-6
In 6/12 TO PTM-1225/1260
In 4/10
In 3/9
In 1/7
In 2/8
P-16 • Preamplifier Module
Zones 13-16
+12VDC Output
Gnd
(-)
13
(+)
14
(+)
15
(+)
16
(+)
Switch
AC
(10A)
Main
AC
Input
Network Control I/O
WARNING! Risk Of Hazardous Energy!
Make Proper Connections.
AVERTISSEMENT! Energie Electrique
Dangereuse!
Faire Des Connexions Propres
Pour L'Hautparleur.
Voir La Notice De Fonctionnement.
CAUTION: Disconnect Supply
Cord Before Servicing.
ATTENTION: Debrancher
Avant Le Depannage.
115V~/60Hz • 230V~/50Hz
500 WATTS MAX
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
ATTENTION!
NE PAS OUVRIR
MADE IN U.S.A.
AVP-16 MR Controller
STANDARD
IEC TO MALE AC CORD
SWITCHED
MAIN AC
L
R
1
L
R
1
L
R
1
2
2 3
2
3
3
4
4 5 6 7
4
5
5
6
6
7
7
8
8 9
P-16
10 11 12
8
P-16
P-16
9
9
10
10
11
11
12
12
13 14
13 14
13 14
15
15
15
16
16
Zones 1- 6 & 7-12
Zones 1-6
In 5/11
In 3/9
Gnd
In 2/8
P-16 • Preamplifier Module
Zones 13-16
+12VDC Output
Gnd
(-)
13
(+)
14
(+)
15
(+)
16
(+)
3 Cntrl
4 +V
ADA Bus®
230V
1 Gnd
2 Fdbk
Zones 1- 6 & 7-12
Zones 1-6
In 6/12 TO PTM-1225/1260
In 5/11 Gnd
In 2/8
P-16 • Preamplifier Module
Zones 13-16
+12VDC Output
Gnd
(-)
13
(+)
14
(+)
15
(+)
16
(+)
115V
1/2 ASB
115V~
1/4 ASB
230V~
115 V
16
Zones 1- 6 & 7-12
Zones 1-6
In 6/12 TO PTM-1225/1260
In 4/10
In 3/9
In 1/7
In 2/8
P-16 • Preamplifier Module
Zones 13-16
+12VDC Output
Gnd 13
Switch
AC
(10A)
Main
AC
Input
Network Control I/O
WARNING! Risk Of Hazardous Energy!
Make Proper Connections.
AVERTISSEMENT! Energie Electrique
Dangereuse!
Faire Des Connexions Propres
Pour L'Hautparleur.
Voir La Notice De Fonctionnement.
CAUTION: Disconnect Supply
Cord Before Servicing.
ATTENTION: Debrancher
Avant Le Depannage.
115V~/60Hz • 230V~/50Hz
500 WATTS MAX
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
ATTENTION!
RISQUE DE CHOC ELECTRIQUE.
NE PAS OUVRIR
MADE IN U.S.A.
AVP-16 MR Controller
IEC MALE TO
FEMALE AC CORD
(ADA#: IEC-MF)
UNSWITCHED
50 PIN RIBBON CABLES
TWO NEEDED
(ADA#: RIBBON-50)
MAIN AC SWITCH FOR BOTH AVP-16's
MASTER UNIT
SLAVE UNIT
POWER
AVP-16
RS-232
POWER
AVP-16
RS-232
SLAVE UNIT'S POWER SWITCH IS REMOVED
& REPLACED WITH COVER PLUG
- 26 -
AVP-16 Main & Slave Unit Power-On Setup
During initial power up sequencing of multiple AVP-16s, it is important that all chassis initialize together in one step. That is why the system needs to have the AC wired were the first Slave
Unit is plugged into the switched AC outlet of the Main Unit and all subsequent Slave Units derive power from the previous Slave Unit’s switched AC outlet. For this reason, ADA will also remove the front panel power button from all Slave Units preventing accidental power sequencing events from ever occurring. As such, Slave Units will have a cover cap in place of the front panel power button.
In order to make certain that the Slave Units sequence power properly, in addition to the appropriate AC wiring and removal of the front panel power switch (on Slave
Units), a special switch, located on the bottom of all AVP-16 chassis, needs to be set in the correct position.
The Master Unit needs to have the switch set toward the back of the chassis as in the top illustration.
The last Slave Unit needs to have its switch set to the position toward the front of the
AVP-16 chassis.
In the case of multiple
Slave Units, those slave units other than the last
Slave Unit, need to be set identical to the Master Unit.
Again, only the final
Slave Unit is set to the position as shown in the diagram at the bottom.
ON/OFF BY
MASTER AVP-16
POWER SWITCH
SET MASTER &
ANY SLAVE UNITS
OTHER THAN LAST
SLAVE UNIT
AVP-16 BOTTOM
(MASTER & SLAVE UNITS
OTHER THAN LAST SLAVE)
ON/OFF BY
MASTER AVP-16
POWER SWITCH
SET LAST
SLAVE UNIT
AVP-16 BOTTOM
(LAST SLAVE UNIT)
- 27 -
AVP-16 ADA Bus & Control Wiring
Suite 16 without other ADA components or Keypads
If you are controlling just an ADA Suite 16 from a non-ADA control interface (i.e. touch screen control system), you can connect directly to the Suite-16’s rear panel RS-232 jack. Please note, that the front panel and rear panel jacks are in parallel and as such, only one can be used at any one time. Thus, if you use the rear panel connection for the control system, the front panel connection will not operate in the event you wish to use your PC and the Suite-16
Setup software.
Suite 16 with other ADA Bus Components (i.e. Trinity Tuner) but no ADA Keypads.
If you are using other ADA Bus Components, such as the Trinity Triple Tuner or a Cinema
Rhapsody (or Reference) Home Theater Preamplifier, yet still only using a non-ADA control system, you will most likely want to network the ADA Bus components on the ADA Bus. By using a WH-2000 Wiring Harness and an ISO-232 ADA Bus to RS-232, you can connect the
Suite-16 and other devices directly to the WH-2000 along with the ISO-232. By using the
ISO-232 as your RS-232 interface, you can now communicate to all ADA Bus Components through a single control system I/O. Furthermore, you free up the Suite-16’s RS-232 port
(either front or rear panel but never both at the same time) for connection to PC for programming using the Suite-16 Setup software.
ADA Bus Wiring Connection
ADA Bus wire by specification is a three conductor 18 gauge tin-coated copper wire with an overall braided shield that is 90% braid. These connections are shown in the heavy black lines in the diagram to the right. In the event ADA Bus wire is not available, you can use a four conductor 16 gauge speaker cable. Please note, that ADA Bus connections are intended strictly for short runs, to connect ADA Bus components to the WH-2000 Wiring Harness.
Because Suite-16 runs at a baud rate of 19200, long runs of this cable will cause inter-component communication to fail. To maintain the best operation at the faster baud rate of 19200,
ADA recommends limiting ADA Bus wiring to a total of 15 feet in length (that is the total distance of all ADA Bus runs). As ADA Bus components are typically in the rack with the
Suite-16, several short ADA Bus connectors, 2 feet in length, are usually employed.
Suite-16 with ADA Controls
When using ADA Keypads including the MC-5011, MC-5000, MC-3000, MC-3800, MC-3000
OD or MC-3800 OD, you will need to wire them with a Cat. 5 cable and RJ-45 connectors at both ends. Standard Cat. 5 cable can be used in runs up to 700 feet in length per run. Clean termination of the RJ-
RJ-45 Cat. 5 Cable Connector
45 jack is essential as this wire carries both control and feedback in addition to voltage. A short in this wire can disrupt control and even damage both keypads and mainframe components. Tone out all terminations prior to connection. In the event a Cat. 5 cable is damaged, see alternate wiring options on the next page.
PIN NUMBER
PIN 1
PIN 2
PIN 3
PIN 4
PIN 5
PIN 6
PIN 7
PIN 8
COLOR
BROWN
BROWN/WHITE
GREEN/WHITE
ORANGE
ORANGE/WHITE
GREEN
BLUE
BLUE/WHITE
FUNCTION
+20V
GND
TX-
RX+
RX-
TX+
+20V
GND
B
L
U
E
W
H
I
T
E
B
L
U
E
G
R
E
E
N
H
I
T
E
W
E
O
R
A
N
G
O
R
A
N
G
E
I
T
E
W
H
G
R
E
E
N
H
I
T
E
B
R
O
W
N
W
8 7 6 5 4 3 2 1
Front
N
B
R
O
W
Top
- 28 -
Cinema Rhapsody Mach II
1
2
1
L
R
VIDEO INPUTS
3 5
4
2
6
3
L
R
7
8
4
VIDEO OUT
1 REC
PIN +/- CHAN
1 / 14
2 / 15
LT
CT
PIN +/-
7 / 20
8 / 21
CHAN
SBL
SBR
3 / 16
4 / 17
RT
SB
9 /10/22
11 / 23
SHLD
R.T.A
5 / 18
6 / 19
SL
SR
12 / 24
13 / 25
R.T.B
R.T.C
MULTI-PIN LFE SUM
0dB +10dB
8 CHANNEL DB-25 INPUT
MAIN REC 1
S-VIDEO INPUTS
2 3 4
1
13
25 14
1
PIN
POINTS
Y
2
5
L
OSD
6 7
L
8
SBL LS
MAIN
L
2
C
COMPONENT VIDEO
P
R/R-Y
Y P
B/B-Y
INPUTS
3
Y
DIGITAL AUDIO
OPTICAL INPUTS
O
UTPUT
P
B
1
P
P
R/R-Y
RECORD
OUT
R
3
ADA NET“
L
R
"Dolby", "Pro Logic", & the double-D Lucasfilm Ltd. U.S. patent numbers
Symbol are trademarks of Dolby
Laboratories. All rights reserved.
Manufactured under license from Digital
Theater Systems, Inc. US Pat. No.
5,451,942, 5,956,764, 5,974,380,
5,978,762 and other worldwide patents issued and pending. "DTS", "DTS-ES
Extended Surround", and "Neo 6" are trademarks of Digital Theater Systems,
Inc. ' 1996, 2000 Digital Theater
Systems, Inc. All rights reserved.
Manufactured under license from
5,043,970; 5,189,703; and/or 5,222,059.
European patent number 0323830.
Other U.S. and foreign patents pending.
Lucasfilm and THX are trademarks or registered trademarks of Lucasfilm Ltd.
Surround EX is a jointly developed technology of THX and Dolby
Laboratories, Inc., and is a trademark of
Dolby. Used under authorization.
DATA PORT
Serial Data
12VDC OUT
100mA Max Per
ADA Bus¤
DC 1 DC 2
1 2 3 4
1- 2+ 1- 2+
C
INEMA
R
HAPSODY ACH
II
H
OME
T
HEATER
C
ONTROLLER
RISK OF ELECTRIC SHOCK
DO NOT OPEN
ATTENTION!
MADE IN U.S.A.
WARNING! Risk Of Hazardous Energy! Make Proper
Connections.
AVERTISSEMENT! Energie Electrique Dangereuse!
Faire Des Connexions Propres Pour L’Hautparleur.
Voir La Notice De Fonctionnement.
CAUTION: Disconnect Supply Cord Before
Servicing.
ATTENTION: Debrancher Avant Le Depannage.
Voltage
Selector &
Safety Fuse
On This Side
115V
115 V
230V
R R
AUDIO INPUTS SBR RS
R
SUB 1 2 3 4 2 4
G
ND
O
UT
I 12V
DC
AC OUTPUT
10A~ Max Switched
AC INPUT
115V~60Hz/230V~50Hz
Use Same
Value Fuse
115V~1AS.B.
230V~.5AS.B.
Trinity Triple Tuner
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
1
2
This device may not cause harmful interference.
This device must accept any interference received, including interference that may cause undesired operation.
TUNER 1
AUDIO OUTPUT
T RINITY T RIPLE
TUNER 2
AUDIO OUTPUT
T UNER
TUNER 3
AUDIO OUTPUT
L L L
ANTENNA ANTENNA
ANTENNA
R R R
OUTPUT
LEVEL
OUTPUT
LEVEL
OUTPUT
LEVEL
BUS
• ICC - INTERACTIVE COMPONENT COMMUNICATION •
®
IR Flasher
Input
The Trinity Does Not
Require a BI-3000.
ADA Bus™
1 2 3 4
115V
115 V
230V
115V 2/10A S.B.
230V 1/10 AS.B.
CAUTION: DISCONNECT SUPPLY
CORD BEFORE SERVICING.
ATTENTION: DEBRANCHER AVANT
LE DEPANNAGE.
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
ATTENTION!
RISQUE DE CHOC ELECTRIQUE.
NE PAS OUVRIR
MADE IN U.S.A.
AC INPUT
Voltage Selector
To Any
Open
L
R
L
R
1
2
1
1
3
4
2
2
5
6
3
3
8
4
4
10
5
5
7
VIDEO INPUTS
9 11
12
6
6
13
14
7
7
15
16
8
8
A-16
P-16
1
V16
2
EXPANSION PORTS
9
9
3
4
10
10
5
6
11
11
7
8
12
12
9
10
13
13
11
12
14
14
13
14
15
15
15
16
16
16
In 1-8
Input Triggers
In 6/14
In 5/13
In 4/12
In 3/11
In 7/15
In 8/16
Gnd
In 1/9
In 2/10
A-16 • Audio Input Module
Balanced
Audio Page
Input (600‰)
1
Com
2
(+)
3
(-)
Trigger
5-24V
AC¥DC
4
(+)
5
(-)
2 Fdbk
3 Cntrl
4 +V
ADA Bus¤
In 9-16
+12VDC Outputs Paging Input/Trigger
Zones 1- 6 & 7-12
Zones 1-6
230V
115V
In 6/12 TO PTM-1225/1260
In 5/11 Gnd
In 2/8
P-16 • Preamplifier Module
Zones 13-16
+12VDC Output
Gnd
(-)
13
(+)
14
(+)
15
(+)
16
(+)
1/2 ASB
115V~
1/4 ASB
230V~
115 V
Out 1-8
Output Triggers
Out 6/14
Out 5/13
Out 4/12
Out 3/11
Out 7/15
Out 8/16
Gnd
Out 1/9
Out 2/10
V-16 • Video I/O Module
Programmed Video
Input Triggers
Gnd
(-)
5-24V AC¥DC
1
(+)
2
(+)
3
(+)
4
(+)
Switch
AC
(10A)
1 Gnd
Network Control I/O
WARNING! Risk Of Hazardous Energy!
Make Proper Connections.
AVERTISSEMENT! Energie Electrique
Dangereuse!
Faire Des Connexions Propres
Pour L’Hautparleur.
Voir La Notice De Fonctionnement.
CAUTION: Disconnect Supply
Cord Before Servicing.
ATTENTION: Debrancher
Avant Le Depannage.
115V~/60Hz ¥ 230V~/50Hz
500 WATTS MAX
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
ATTENTION!
NE PAS OUVRIR
MADE IN U.S.A.
Out 9-16
+12VDC Outputs Input Triggers
Main
AC
Input
AVP-16 MR Controller
ADA Bus to WH-2000 J1
IRL-5000
Set to Address 1
For Sources 1-8
IRL-5000
Set to Address 2
For Sources 9-16
To RS-232 Control
System or AMX or
Crestron Control System
RS-232
Pins
2=Tx
3=Rx
5=Com
IR Repeating Only
40KHz IR Repeat
Frequency
IR Flasher=Remove Jumper
Serial Direct=Insert Jumper
Repeater
IR - Serial
Serial
Data Only
1 2 3 4
Gnd Rx Tx +15V
ADA Bus¤
ADA/232
Source Ports: 1 2 3 4 5 6 7 8
Data/Carrier
Off Norm Invert
Repeater
IR - Serial
Serial
Data Only
Off Norm Invert
RS-232
ADA Bus
Repeater
IR - Serial
Serial
Data Only
Off Norm Invert
Repeater
IR - Serial
Serial
Data Only
1
2
3
Off Norm Invert
Repeater
IR - Serial
Serial
Data Only
4
5
IRL-5000
Source Controller
Off Norm Invert
Repeater
IR - Serial
Serial
Data Only
PGM DEL
Power On/Off IR Macro
Connect To Mainframe
Source DC Triggers &
ACC-48 AC Controllers
Off Norm Invert
Repeater
IR - Serial
Serial
Data Only
6
7
CON ERR
Off Norm Invert
Repeater
IR - Serial
Serial
Data Only
Off
Norm Invert 8
RS-232
Pins
2=Tx
3=Rx
5=Com
RS-232
ADA Bus
IR Repeating Only
40KHz IR Repeat
Frequency
1 2 3 4
Gnd Rx Tx +15V
ADA Bus¤
Data/Carrier
ADA/232
Source Ports: 1 2 3 4 5 6 7 8
IR Flasher=Remove Jumper
Serial Direct=Insert Jumper
Repeater
IR - Serial
Serial
Data Only
Off Norm Invert
Repeater
IR - Serial
Serial
Data Only
Off Norm Invert
Repeater
IR - Serial
Serial
Data Only
Off Norm Invert
Repeater
IR - Serial
Serial
Data Only
1
2
3
Off Norm Invert
Repeater
IR - Serial
Serial
Data Only
4
5
PGM DEL
IRL-5000
Source Controller
Power On/Off IR Macro
Connect To Mainframe
Source DC Triggers &
ACC-48 AC Controllers
Off Norm Invert
Repeater
IR - Serial
Serial
Data Only
Off Norm Invert
Repeater
IR - Serial
Serial
Data Only
6
7
CON ERR
Off Norm Invert
Repeater
IR - Serial
Serial
Data Only
Off Norm Invert 8
ISO-232
RS-232 ADA BUS
Normal
Reverse
(TuneBase)
1 2 3 4
To Aquarius Hard-Drive
CD Library or Escient
Tunebase Pro MK III
ISO-232
RS-232 ADA BUS
Normal
Reverse
(TuneBase)
1 2 3 4
ISO-232
ADA Bus to RS-232 Converter
ADA Bus
To Any
Open
WH-2000
ADA Bus
Jumper
J2 to J1
WH-2000
1 2 3 4
J1
J2
J3
J4
J5
RJ45
RJ45
RJ45
RJ45
RJ45
RJ45
RJ45
RJ45
WH-2000
ADA Bus
To Any
Open
1 2 3 4
J1
J2
J3
J4
J5
RJ45
RJ45
RJ45
RJ45
RJ45
RJ45
RJ45
RJ45
WH-2000
WH-2000
Wire Harness
Cat. 5
To Any
Open
Cat. 5
To Any
Open
FM1
AM
CD2
DVD
FM2
CD1
DSS
AUX
OFF
VOL
F F
BASS
EXTRA
VOL
1
4
7
*
8
0
2
5
3
6
9
ENT
TREB
OFF
SHIFT
FM1
AM
CD2
DVD
FM2
CD1
DSS
AUX
OFF
VOL
F F
BASS
EXTRA
VOL
1
4
7
*
8
0
2
5
3
6
9
ENT
TREB
OFF
MC-5011
FM 1 FM 2 AM CD 1 CD 2 DSS DVD AUX
VOL PTY 1 PTY 2
OFF
MC-5000
MC-3000 OD
MC-5011
MC-5000
- 29 -
Damaged Wiring Options
In the event that a Cat. 5 cable is damaged, you can still get an MC-5000, MC-5011, MC-3000, MC-3800, MC-3000
OD, or MC-3800 OD to operate, providing that six of the eight Cat. 5 wires are good. To do so, eliminate the first wire and the eighth wire from the RJ-45 connector, at both the wire harness and keypad termination point. Please note, you cannot re-wire an MC-6000 (Keypad with Video
Display) in this manner. The above keypads wired in this fashion will work as all other keypads.
RJ-45 Cat. 5 Cable Connector
B
L
U
E
G
R
E
E
N
I
T
E
E
W
H
O
R
A
N
G
O
R
A
N
G
E
W
H
I
T
E
G
R
E
E
N N
W
H
B
R
O
W
I
T
E
8 7 6 5 4 3 2 1
Front Top
CAT-Link and ADA Bus Wiring
In some cases, you may end up upgrading a project previously wired with ADA Bus four conductor wiring. As all Suite 16 keypads have only RJ-45 Cat
Link termination, you will require the BUS-CAT Module per keypad. This in-line ADA Bus screw terminal connection to male RJ-
+15V Tx Rx Gnd
4 3 2 1
45 jack will permit the keypads to connect to the system. Here
ADA suggests using the WH-3000 Wiring Harness (all ADA Bus ADA Bus jacks) to terminate the ADA Bus keypad wiring at the mainframe, while the keypads themselves terminate with RJ-45. In this situation, you will need to run the Suite 16 System at a baud rate of
1200 because the ADA Bus wire to the keypad location is not fast enough for the optimal system baud rate of 19200. When running the Suite 16 System at 1200, the initial (when the power switch on the Suite 16 is first turned on) power up sequence will take slightly longer. Also, at 1200 baud, using more than two Aquarius outputs will most likely slow system operation down some. Otherwise, most system features will work without incidence.
Top
RJ-45
IR Repeating
Whether you are running a Suite 16 System at 1200 baud or the standard 19200 baud, the IR receivers mounted in the MC-5000, MC-5011, MC-3000 and MC-3800 can IR repeat to source components via the IRL-5000. This will permit you to use the original source remote control from a remote room location. Please note, that while most source components operate at 40KHz, some do not and as such, will not IR repeat through the IRL-5000. The IRL-5000 has a trim pot adjustment for the IR carrier frequency which is only used to fine-tune IR repeating. Also, in order to employ IR repeating, the keypad’s IR needs to be active. On the MC-5011, this requires that the jumper pin on the circuit board be in place. On the other keypads, the IR receiver is turned on and off via on-keypad programming.
Also, the ports on the IRL-5000 need to have their jumper pins set so that IR repeating is active.
RS-232
Pins
2=Tx
3=Rx
5=Com
IR Repeating Only
40KHz IR Repeat
Frequency Repeater
IR - Serial
Serial
Data Only
1 2 3 4
Gnd Rx Tx +15V
ADA Bus®
ADA/232
Source Ports: 1 2 3 4 5 6 7 8
Data/Carrier
Off Norm Invert
Repeater
IR - Serial
Serial
Data Only
IR Flasher=Remove Jumper
Serial Direct=Insert Jumper Off Norm Invert
RS-232
ADA Bus
Repeater
IR - Serial
Serial
Data Only
Off
Norm Invert
Repeater
IR - Serial
Serial
Data Only
1
2
3
Off Norm Invert
Repeater
IR - Serial
Serial
Data Only
4
5
IRL-5000
Source Controller
Power On/Off IR Macro
Connect To Mainframe
Source DC Triggers &
ACC-48 AC Controllers
Off
Norm Invert
Repeater
IR - Serial
Serial
Data Only
Off Norm Invert
Repeater
IR - Serial
Serial
Data Only
6
7
PGM DEL
Off
Norm Invert
Repeater
IR - Serial
Serial
Data Only
CON ERR
8
Off
Norm Invert
- 30 -
IR Control of the Suite 16
ADA provides the RC-40 hand-held IR Remote Control for wireless infrared control of the Suite-16 and source components.
This unit features the same button layout as an MC-5000 and like any system keypad, the RC-40 is programmed for a specific room. As such, it cannot be taken from one room to the next. If this is done, the RC-40 will still control the room it is programmed for. The RC-40 issues commands at 1200 baud
(IR cannot be passed at 19200 baud) and can be aimed at an
IRR-5000 or any ADA keypad (providing that its IR receivers is active).
To
Trinity
To
Suite-16
F
M
1
F
M
2
BASS
EXTRA
VOL
A
M
C
D
1
C
D
2
D
S
S
D
V
D
A
U
X
*
1
4
7
2
5
8
0
3
6
9
ENT
TREB
OFF
For systems set to run at the optimal factory baud rate setting of 19,200, you will need to include a single BRT-1 Baud
Rate Translator in the system.
The BRT-1 is connected to any open ADA Bus jack on either the WH-2000 or WH-6000. IR commands issued by the RC-
40 are up-converted to 19200 by the BRT-1, so the Suite 16, as well as any other ADA Bus component (Trinity Tuner), will perform the function selected
RS-232
Pins
2=Tx
3=Rx
5=Com
IR Repeating Only
40KHz IR Repeat
Frequency Repeater
IR - Serial
Serial
Data Only
1 2 3 4
Gnd Rx Tx +15V
ADA BusÆ
Source Ports:
Data/Carrier
1 2 3 4 5 6 7 8
ADA/232
IR Flasher=Remove Jumper
Serial Direct=Insert Jumper
Off
Repeater
IR - Serial
Norm Invert
Serial
Data Only
Off Norm Invert
RS-232
ADA Bus
Repeater
IR - Serial
Serial
Data Only
Off
Repeater
IR - Serial
Norm Invert
Serial
Data Only
1
2
3
PGM DEL
IRL-5000
Source Controller
Power On/Off IR Macro
Connect To Mainframe
Source DC Triggers &
ACC-48 AC Controllers
Off Norm Invert
Repeater
IR - Serial
Serial
Data Only
Off
Repeater
IR - Serial
Norm Invert
Serial
Data Only
4
5
Off Norm Invert
Repeater
IR - Serial
Serial
Data Only
Off
Repeater
IR - Serial
Norm Invert
Serial
Data Only
6
7
CON ERR
Off Norm Invert 8
IRL-5000
IRR-5000
BRT-1
ADA Bus
4 +VDC
3 Data
2 Data
Translation
In Process Power
DIP Switches
Do Not Matter
BRT-1
Baud Rate Translator (1200 to 19200)
IRR-5000
WH-2000
1 2 3 4
J1
J2
J3
J4
J5
RJ45
RJ45
RJ45
RJ45
RJ45
RJ45
RJ45
RJ45
WH-2000
Cat. 5
To Any
Open
IRR-5000
FM1
AM
CD2
DVD
FM2
CD1
DSS
AUX
OFF
VOL
F
M
1
F
2
A
M
C
D
1
C
D
2
D
S
S
D
V
D
A
U
X
BASS
EXTRA
VOL
1
4
7
*
2
5
8
0
3
6
9
ENT
TREB
OFF
M
1
F
M
2
A
M
C
D
1
C
D
2
D
S
S
D
V
D
A
U
X
F
M
1
F
M
2
A
M
C
D
1
C
D
2
D
S
S
D
V
D
A
U
X
F
M
1
F
2
A
M
C
D
1
C
D
2
D
S
S
D
V
D
A
U
X
BASS 2
5
8
0
3
6
9
TREB BASS 1
4
7
2
5
8
0
3
6
9
TREB BASS 1
4
7
2
5
8
0
3
6
9
TREB
For systems running at 1200 baud, no BRT-1 is required for
EXTRA
VOL *
1
4
7
ENT OFF
EXTRA
VOL * ENT OFF
EXTRA
VOL * ENT OFF
IR control. For these systems, all ADA Bus components will
RC-40
Room Specific
RC-40
Room Specific
RC-40
Room Specific need to be set to 1200 baud. ADA strongly suggests avoiding running systems at 1200 baud, especially when using more than 32 zones and/or the Aquarius Hard Drive Jukebox, as there will be too much bus traffic for smooth operation of the system.
Front Side Back
ADA also provides the IRR-5000 peep-hole IR
Receiver that features an RJ-45 connector. This receiver is ideally run to an open RJ-45 connec-
O
N
/O
FF
T
X
1.264" .99" tor on the system wire harness.
The IRR-5000 can also be used
RJ-45
Female for only IR repeating, if the system is running at 19200 without a BRT-1.
Turn off IRT-232 when not in use.
P
OWER
RS-232
IRT-232
R
X
RS-232 I
NFRARED
T
RANSCEIVER
You can also generate IR commands for capture by other IR transmitting devices using the IRT-232. The IRT-232 connects to your PC and features an IR
Transceiver. When using the Suite 16 Tester program and an IRT-232, you can generate most any Suite 16 command in IR form. Again, it is important to remember that all commands are room specific and emit at 1200 baud.
- 31 -
RF Control
ADA provides an RF control option for Suite 16 Systems operating at either 1200 baud or 19200 baud. This involves using a single RFT-3000 RF Transceiver per system. The keypads that RFT-3000 can be controlled via RF include the MC-5000, MC-3000, MC-
3800, MC-3000 OD, and MC-3800 OD. The MC-5011 and MC-
6000 cannot be controlled via RF. Please note, while control via RF is possible, with complete feedback, the keypads still will require power.
RF control becomes an option, when wiring is damaged or not the improper type (a two conductor cable). If the wiring to keypad locations provides only four wires, because of damage or improper planning, then employing the RF
Control option becomes a viable option. Here, the existing wires can be used for power only, while all communication and feedback take place via RF. Here, in addition to the system requiring one RFT-3000 RF Transceiver, each keypad will also require the RFT-MOD RF Module which is connected to the keypad at the ADA factory.
RJ-45 Cat. 5 Cable Connector
H
I
T
E
B
L
U
E
W
B
L
U
E
N
W
H
I
B
R
O
W
T
E
N
B
R
O
W
8 7 6 5 4 3 2 1
Front
Alternately, you can employ the RF Control option for rooms where no wire can be run. In this case, instead of using an in-wall keypad, you can use the MC-5000
Table-Top control with RFT-MOD. This keypad will ship with a power supply which can be plugged into any AC outlet. The keypad can be used outdoors but it is not waterproof in any manner and should not be left outside.
F
M
1
F
M
2
A
M
C
D
1
C
D
2
D
S
S
D
V
D
A
U
X
Top
15VDC
Whether you use an in-wall or table-top RF keypad, ADA suggests running your Suite 16
System at a baud rate of 19200 for optimum performance. For the most part, function from an RF control is identical to a hard-wired con-
BASS
EXTRA
VOL *
1
4
7
2
5
8
0
3
6
9
ENT
TREB
OFF trol. To the end user, there is no difference.
When installing the controls, in addition to the normal setting of the controls baud rate to match the system, you must also make certain that the RFT-3000 and RFT-MOD dip switch settings are set to the same baud rate. Finally, you will also need to make certain that the addresses match on the RFT-3000 and the RFT-MOD. Both the RF baud rate and address are set using the four switch DIP switch on the RFT-3000 and RFT-MOD. Please note, that you select one address setting per system, as these addresses have nothing to do with zones.
RFT-3000
Dip Switch Settings
(Must match RFT-MOD)
SWITCH NO.
1
19,200 BAUD U P
1,200 BAUD D N
SWITCH NO.
ADDRESS 1
ADDRESS 2
ADDRESS 3
ADDRESS 4
ADDRESS 5
ADDRESS 6
ADDRESS 7
ADDRESS 8
2 3 4
U P U P U P
D N U P U P
U P D N U P
D N D N U P
U P U P D N
D N U P D N
U P D N D N
D N D N D N
SWITCH NO.
ADDRESS 1
ADDRESS 2
ADDRESS 3
ADDRESS 4
ADDRESS 5
ADDRESS 6
ADDRESS 7
ADDRESS 8
1 2 3
U P U P U P
U P U P D N
U P D N U P
U P D N D N
D N U P U P
D N U P D N
D N D N U P
D N D N D N
Keypad RFT-MOD
Dip Switch Settings
(Must match RFT-3000)
SWITCH NO.
4
19,200 BAUD U P
1,200 BAUD D N
- 32 -
In the diagram below, you can see that it is possible to mix and match keypads that are both hardwired, hardwired for power but running on RF for control and feedback, or completely wireless using an AC transformer. Only one RFT-3000 is required per system.
Trinity Triple Tuner
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
1 This device may not cause harmful interference.
2 This device must accept any interference received, including interference that may cause undesired operation.
TUNER 1
AUDIO OUTPUT
T
RINITY
T
RIPLE
TUNER 2
AUDIO OUTPUT
T
UNER
TUNER 3
AUDIO OUTPUT
L
R
OUTPUT
LEVEL
ANTENNA
L
R
OUTPUT
LEVEL
ANTENNA
L
R
OUTPUT
LEVEL
ANTENNA
BUS ®
• ICC - INTERACTIVE COMPONENT COMMUNICATION •
IR Flasher
Input
The Trinity Does Not
Require a BI-3000.
ADA Bus™
1 2 3 4
115 V
115V 230V
115V 2/10A S.B.
230V 1/10 AS.B.
CAUTION: DISCONNECT SUPPLY
CORD BEFORE SERVICING.
ATTENTION: DEBRANCHER AVANT
LE DEPANNAGE.
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
ATTENTION!
RISQUE DE CHOC ELECTRIQUE.
NE PAS OUVRIR
MADE IN U.S.A.
AC INPUT
Voltage Selector
L
R
L
R
1
2
1
1
3
4
2
2
5
6
3
3
8
4
4
10
5
5
7
VIDEO INPUTS
9 11
12
6
6
13
14
7
7
15
16
8
8
A-16
P-16
1
V16
2
EXPANSION PORTS
9
9
3
4
10
10
5
6
11
11
7
8
12
12
9
10
13
13
11
12
14
14
13
14
15
15
15
16
16 In 1-8
Input Triggers
In 6/14
In 5/13
In 4/12
In 3/11
In 7/15
In 8/16
Gnd
In 1/9
In 2/10
A-16 Audio Input Module
Balanced
Audio Page
Input (600 )
1 2 3
Com (+) (-)
Trigger
5-24V
AC DC
4 5
(+) (-)
16
In 9-16
+12VDC Outputs
Paging Input/Trigger
Zones 1- 6 & 7-12
Zones 1-6
In 6/12 TO PTM-1225/1260
In 5/11
In 4/10
In 3/9
Gnd
In 1/7
In 2/8
P-16 Preamplifier Module
Zones 13-16
+12VDC Output
Gnd
(-)
13
(+)
14
(+)
15
(+)
16
(+)
1/2 ASB
115V~
1/4 ASB
230V~
Out 1-8
Output Triggers
Out 6/14
Out 5/13
Out 4/12
Out 3/11
Out 7/15
Out 8/16
Gnd
Out 1/9
Out 2/10
V-16 Video I/O Module
Programmed Video
Input Triggers
5-24V AC DC
Gnd
(-)
1
(+)
2
(+)
3
(+)
4
(+)
Out 9-16
+12VDC Outputs
Input Triggers
1 Gnd
Network Control I/O
2 Fdbk
3 Cntrl
4 +V
ADA BusÆ
230V
115V
115 V
Switch
AC
(10A)
Main
AC
Input
WARNING! Risk Of Hazardous Energy!
Make Proper Connections.
AVERTISSEMENT! Energie Electrique
Dangereuse!
Faire Des Connexions Propres
Pour L'Hautparleur.
Voir La Notice De Fonctionnement.
CAUTION: Disconnect Supply
Cord Before Servicing.
ATTENTION: Debrancher
Avant Le Depannage.
115V~/60Hz 230V~/50Hz
500 WATTS MAX
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
ATTENTION!
RISQUE DE CHOC ELECTRIQUE.
NE PAS OUVRIR
MADE IN U.S.A.
AVP-16 MR Controller
Video Out Room 4-6
ADA Bus to WH-2000 J1
RS-232
Pins
2=Tx
3=Rx
5=Com
IR Repeating Only
40KHz IR Repeat
Frequency
Repeater
IR - Serial
Serial
Data Only
1 2 3 4
Gnd Rx Tx +15V
ADA BusÆ
ADA/232
Source Ports: 1 2 3 4 5 6 7 8
Data/Carrier
Off
Norm Invert
Repeater
IR - Serial
Serial
Data Only
IR Flasher=Remove Jumper
Serial Direct=Insert Jumper
Off Norm Invert
RS-232
ADA Bus
Repeater
IR - Serial
Serial
Data Only
Off
Norm Invert
Repeater
IR - Serial
Serial
Data Only
1
2
3
Off Norm Invert
Repeater
IR - Serial
Serial
Data Only
4
5
IRL-5000
Source Controller
Off Norm Invert
Repeater
IR - Serial
Serial
Data Only
PGM DEL
CON ERR
Power On/Off IR Macro
Connect To Mainframe
Source DC Triggers &
ACC-48 AC Controllers
Off Norm Invert
Repeater
IR - Serial
Serial
Data Only
6
7
Off
Norm Invert
Repeater
IR - Serial
Serial
Data Only
Off Norm Invert
8
IRL-5000
WH-2000
1 2 3 4
J1
J2
J3
J4
J5
RJ45
RJ45
RJ45
WH-2000
RJ45
RJ45
RJ45
RJ45
RJ45
Cat. 5
To Any
Open
FM1
AM
CD2
DVD
FM2
CD1
DSS
AUX
OFF
VOL
F
M
1
F
M
2
A
M
C
D
1
C
D
2
D
S
S
D
V
D
A
U
X
BASS
EXTRA
VOL *
1
4
7
2
5
8
0
3
6
9
ENT
TREB
OFF
MC-5011
RFT-3000
F
M
1
F
M
2
A
M
C
D
1
C
D
2
D
S
S
D
V
D
A
U
X
BASS
EXTRA
1
4
7
2
5
8
0
3
6
9
TREB
VOL * ENT OFF
MC-5000T RF
15VDC
F
M
1
F
M
2
A
M
C
D
1
C
D
2
D
S
S
D
V
D
A
U
X
BASS
EXTRA
1
4
7
2
5
8
0
3
6
9
TREB
VOL * ENT OFF
MC-5000T RF
- 33 -
15VDC
F
M
1
F
M
2
A
M
C
D
1
C
D
2
D
S
S
D
V
D
A
U
X
BASS
EXTRA
1
4
7
2
5
8
0
3
6
9
TREB
VOL * ENT OFF
MC-5000T RF
15VDC
MC-6000 Keypad with Video, WH-6000, & TV-6000
The MC-6000 Keypad fits a four-gang box and in addition to the MC-5000 Rapture Keypad, features a small LCD preview display. There are also five navigation buttons below the screen for up, down, right, left, and enter (select) control. The enter button is also found on the MC-5000 numeric button area. The IRL-5000 has the directional buttons available and much like any transport function, the keypad’s 12 character LED display can read these function names when pressed.
F
M
1
F
M
2
BASS
EXTRA
VOL
A
M
1
4
7
*
C
D
1
2
5
8
0
C
D
2
D
S
S
D
V
D
A
U
X
3
6
9
ENT
TREB
OFF
The MC-6000 runs on the same Cat. 5 cable that you would use for an MC-5011, MC-5000, or MC-3000 OD. Termination is also the same. However, the MC-6000 uses these eight wires slightly differently, since composite video is also passed along the single Cat. 5 cable. As such, in order for the MC-6000 to display video, you will need to use the WH-
6000 Wiring Harness. The WH-6000 features eight RJ-45 jacks that correspond to the eight composite video input jacks. If an MC-6000 is connected to RJ-45 jack number three, then the composite video output for that display must connect to composite video input number three. Each composite video input on the WH-6000 also has a Hi-Z/75 Ω
Normal switch. If you are splitting this video signal to perhaps drive two MC-6000’s on the same zone, then you will need to set one of these switches to Hi-Z while the second
WH-6000 composite video input is set to normal.
Video
In 1
75
Ω
Hi-Z
Video
In 2
75
Ω
Hi-Z
H.F. Trim
Cat-Link 1
Gain Trim
H.F. Trim
Cat-Link 2
Gain Trim
Video
In 5
75
Ω
Hi-Z
Video
In 6
75
Ω
Hi-Z
Video
In 3
75
Ω
Hi-Z
Video
In 4
75
Ω
Hi-Z
H.F. Trim
Cat-Link 3
Gain Trim
H.F. Trim
Cat-Link 4
Gain Trim
H.F. Trim
Cat-Link 5
Gain Trim
H.F. Trim
Cat-Link 6
Gain Trim
Video
In 7
75
Ω
Hi-Z
Video
In 8
75
Ω
Hi-Z
H.F. Trim
Cat-Link 7
Gain Trim
H.F. Trim
Cat-Link 8
Gain Trim
WH-6000
Tx
Rx
Bus Power
ADA Bus
+V Tx Rx Gnd
4 3 2 1
RJ-45 Cat-Link
8 7 6 5 4 3 2 1
In
Loop
Out
I/O 1
I/O 2
I/O 3
Cat-Link 1 Out
Cat-Link 2 Out
Cat-Link 3 Out
Cat-Link 4 Out
Cat-Link 5 Out
Cat-Link 6 Out
Cat-Link 7 Out
Cat-Link 8 Out
ADA also provides the TV-6000 which is a small black box that features an RJ-45 input and a composite video output. This permits you to drive a video signal to a TV by running Cat. 5 cable to the TV which will be fitted with the TV-6000. Again, if a composite video signal is “Y” split to input to two jacks on the
WH-6000, and one RJ-45 connector is running to an MC-6000 while the other is running to a TV-6000 for connection to a TV set, then one Hi-Z/75 Ω switch would be set to Hi-Z while the other is set to 75 Ω (Normal). In the event you did not run an
Cat.-5 Cable from the mainframe to the TV location but can run a jumper Cat. 5 cable from the keypad to the TV, you can opt to run video to the TV this way as well.
Video Output (75 Ω)
RJ-45 Cat-Link
8 7 6 5 4 3 2 1
H.F. Gain Pull Shunting Pin
For Hi-Z Input
TV-6000
Cat-Link Video Receiver
Cat-Link Video Input
(From WH-6000)
While the MC-5011, MC-5000, MC-3000 OD, and/or MC-3800 OD keypads can be used with the WH-2000 or WH-6000 Wire Harness, the MC-6000 can only be used with the WH-6000
Wire Harness. When using the MC-5011, MC-5000, MC-3000 OD, and/or MC-3800 OD keypads on a WH-6000, special settings must be made in order to permit the keypads to operate properly. See the instructions included with the WH-6000 regarding these settings.
- 34 -
Cinema Rhapsody Mach II
1
2
1
L
R
VIDEO INPUTS
3 5
4
2
6
3
L
R
7
8
4
VIDEO OUT
1 REC
PIN +/- CHAN
1 / 14 LT
2 / 15
3 / 16
CT
RT
PIN +/CHAN
7 / 20
8 / 21
9 /10/22
SBL
SBR
SHLD
4 / 17
5 / 18
SB
SL
11 / 23
12 / 24
R.T.A
R.T.B
6 / 19 SR 13 / 25 R.T.C
MULTI-PIN LFE SUM
0dB +10dB
8 CHANNEL DB-25 INPUT
S-VIDEO INPUTS
MAIN REC 1 2 3 4
2
5
L
OSD
6 7
L
8
SBL LS
MAIN
L
13
25 14
1 PIN
POINTS
Y
1
2
C
COMPONENT VIDEO
P
R/R-Y
Y P
B/B-Y
3
Y
DIGITAL AUDIO
INPUTS
OPTICAL INPUTS
O
UTPUT
P
B
1
P
R
3
P
R/R-Y
RECORD
OUT
ADA NETô
L
R
"Dolby", "Pro Logic", & the double-D
Symbol are trademarks of Dolby
Laboratories. All rights reserved.
Manufactured under license from Digital
Theater Systems, Inc. US Pat. No.
5,451,942, 5,956,764, 5,974,380,
5,978,762 and other worldwide patents issued and pending. "DTS", "DTS-ES
Extended Surround", and "Neo 6" are trademarks of Digital Theater Systems,
Inc. © 1996, 2000 Digital Theater
Systems, Inc. All rights reserved.
Manufactured under license from
Lucasfilm Ltd. U.S. patent numbers
5,043,970; 5,189,703; and/or 5,222,059.
European patent number 0323830.
Other U.S. and foreign patents pending.
Lucasfilm and THX are trademarks or registered trademarks of Lucasfilm Ltd.
Surround EX is a jointly developed technology of THX and Dolby
Laboratories, Inc., and is a trademark of
Dolby. Used under authorization.
DATA PORT
Serial Data
ADA BusÆ
12VDC OUT
100mA Max Per
DC 1 DC 2
1 2 3 4
1- 2+ 1- 2+
R R
AUDIO INPUTS SBR RS R SUB 1 2 3 4 2 4
O
UT
I
N
12V
DC
C
H
OME
CAUTION
DO NOT OPEN
ATTENTION!
RISQUE DE CHOC ELECTRIQUE.
NE PAS OUVRIR
MADE IN U.S.A.
M ACH II
HEATER
C
ONTROLLER
WARNING! Risk Of Hazardous Energy! Make Proper
Connections.
AVERTISSEMENT! Energie Electrique Dangereuse!
Faire Des Connexions Propres Pour L'Hautparleur.
Voir La Notice De Fonctionnement.
CAUTION: Disconnect Supply Cord Before
Servicing.
ATTENTION: Debrancher Avant Le Depannage.
Voltage
Selector &
Safety Fuse
On This Side
115V
115 V
230V
AC OUTPUT
10A~ Max Switched
AC INPUT
115V~60Hz/230V~50Hz
Use Same
Value Fuse
115V~1AS.B.
230V~.5AS.B.
Trinity Triple Tuner
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
1
2
This device may not cause harmful interference.
This device must accept any interference received, including interference that may cause undesired operation.
T
RINITY
T
RIPLE
T
UNER
TUNER 1
AUDIO OUTPUT
TUNER 2
AUDIO OUTPUT
TUNER 3
AUDIO OUTPUT
L
R
OUTPUT
LEVEL
ANTENNA
L
R
OUTPUT
LEVEL
ANTENNA
L
R
OUTPUT
LEVEL
ANTENNA
BUS
• ICC - INTERACTIVE COMPONENT COMMUNICATION •
®
The Trinity Does Not
Require a BI-3000.
IR Flasher
Input
ADA Bus™
1 2 3 4
115V
115 V
230V
115V 2/10A S.B.
230V 1/10 AS.B.
CAUTION: DISCONNECT SUPPLY
CORD BEFORE SERVICING.
ATTENTION: DEBRANCHER AVANT
LE DEPANNAGE.
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
ATTENTION!
RISQUE DE CHOC ELECTRIQUE.
NE PAS OUVRIR
MADE IN U.S.A.
AC INPUT
Voltage Selector
WH-6000 & TV-6000
Cat-Link Termination
(Control, Power, & Video)
RJ-45 Cat. 5 Cable Connector
H
I
T
E
B
L
U
E
W
B
L
U
E
G
R
E
E
N
W
H
I
T
E
N
G
E
O
R
A
O
R
A
N
G
E
H
I
T
E
E
N
W
G
R
E
N
W
H
I
B
R
O
W
T
E
B
R
O
W
N
8 7 6 5 4 3 2 1
L
R
L
R
1
2
1
1
3
4
2
2
5
6
3
3
8
4
4
10
5
5
7
VIDEO INPUTS
9 11
12
6
6
13
14
7
7
15
16
8
8
A-16
P-16
V-
1
16
2
EXPANSION PORTS
9
9
3
4
10
10
5
6
11
11
7
8
12
12
9
10
13
13
11
12
14
14
13
14
15
15
15
16
16 In 1-8
Input Triggers
In 6/14
In 5/13
In 4/12
In 3/11
In 7/15 In 8/16
Gnd
In 1/9
In 2/10
A-16 Audio Input Module
Balanced
Audio Page
Input (600 )
1
Com
2
(+)
3
(-)
Trigger
5-24V
AC DC
4
(+)
5
(-)
In 9-16
+12VDC Outputs Paging Input/Trigger
16
Zones 1- 6 & 7-12
Zones 1-6
In 5/11
In 3/9
Gnd
In 2/8
P-16 Preamplifier Module
Zones 13-16
+12VDC Output
Gnd
(-)
13
(+)
14
(+)
15
(+)
16
(+)
1/2 ASB
115V~
1/4 ASB
230V~
2 Fdbk
3 Cntrl
4 +V
ADA BusÆ
230V
1 Gnd
Network Control I/O
115V
115 V
Out 1-8
Output Triggers
Out 6/14
Out 5/13
Out 4/12
Out 3/11
Out 7/15 Out 8/16
Gnd
Out 1/9
Out 2/10
V-16 Video I/O Module
Programmed Video
Input Triggers
Gnd
(-)
5-24V AC DC
1
(+)
2
(+)
3
(+)
4
(+)
Out 9-16
+12VDC Outputs Input Triggers
Switch
AC
(10A)
Main
AC
Input
WARNING! Risk Of Hazardous Energy!
Make Proper Connections.
AVERTISSEMENT! Energie Electrique
Dangereuse!
Faire Des Connexions Propres
Pour L'Hautparleur.
Voir La Notice De Fonctionnement.
CAUTION: Disconnect Supply
Cord Before Servicing.
ATTENTION: Debrancher
Avant Le Depannage.
115V~/60Hz 230V~/50Hz
500 WATTS MAX
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
ATTENTION!
RISQUE DE CHOC ELECTRIQUE.
NE PAS OUVRIR
MADE IN U.S.A.
AVP-16 MR Controller
Video Out Room 4-6
ADA Bus to WH-2000 J1
RS-232
Pins
2=Tx
3=Rx
5=Com
IR Repeating Only
40KHz IR Repeat
Frequency
IR Flasher=Remove Jumper
Serial Direct=Insert Jumper
Repeater
IR - Serial
Serial
Data Only
1 2 3 4
Gnd Rx Tx +15V
ADA Busfi
ADA/232
Source Ports: 1 2 3 4 5 6 7 8
Data/Carrier
Off
Repeater
IR - Serial
Norm Invert
Serial
Data Only
Off Norm Invert
RS-232
ADA Bus
Repeater
IR - Serial
Serial
Data Only
Off
Repeater
IR - Serial
Norm Invert
Serial
Data Only
1
2
3
Off Norm Invert
Repeater
IR - Serial
Serial
Data Only
4
5
IRL-5000
Source Controller
Off
Repeater
IR - Serial
Norm Invert
Serial
Data Only
PGM DEL
Power On/Off IR Macro
Connect To Mainframe
Source DC Triggers &
ACC-48 AC Controllers
Off Norm Invert
Repeater
IR - Serial
Serial
Data Only
6
7
CON ERR
Off
Repeater
IR - Serial
Norm Invert
Serial
Data Only
Off
Norm Invert 8
RS-232
Pins
2=Tx
3=Rx
5=Com
IR Repeating Only
40KHz IR Repeat
Frequency
IR Flasher=Remove Jumper
Serial Direct=Insert Jumper
Repeater
IR - Serial
Serial
Data Only
1 2 3 4
Gnd Rx Tx +15V
ADA Busfi
ADA/232
Source Ports: 1 2 3 4 5 6 7 8
Data/Carrier
Off
Repeater
IR - Serial
Norm Invert
Serial
Data Only
Off Norm Invert
RS-232
ADA Bus
Repeater
IR - Serial
Serial
Data Only
Off
Repeater
IR - Serial
Norm Invert
Serial
Data Only
1
2
3
Off Norm Invert
Repeater
IR - Serial
Serial
Data Only
4
5
IRL-5000
Source Controller
Off
Repeater
IR - Serial
Norm Invert
Serial
Data Only
PGM DEL
CON ERR
Power On/Off IR Macro
Connect To Mainframe
Source DC Triggers &
ACC-48 AC Controllers
Off Norm Invert
Repeater
IR - Serial
Serial
Data Only
6
7
Off
Repeater
IR - Serial
Norm Invert
Serial
Data Only
Off
Norm Invert 8
WH-2000
1 2 3 4
J1
J2
J3
J4
J5
WH-2000
RJ45
RJ45
RJ45
RJ45
RJ45
RJ45
RJ45
RJ45
Cat. 5
To Any
Open
FM1
AM
CD2
DVD
FM2
CD1
DSS
AUX
OFF
VOL
Front Top
PIN NUMBER
PIN 1
PIN 2
PIN 3
PIN 4
PIN 5
PIN 6
PIN 7
PIN 8
COLOR
BROWN
BROWN/WHITE
GREEN/WHITE
ORANGE
ORANGE/WHITE
GREEN
BLUE
BLUE/WHITE
FUNCTION
+20V
GND
TX-
RX+
RX-
TX+
+ VIDEO
- VIDEO
MC-5011
Room 1
F
M
1
F
2
A
M
C
D
1
C
D
2
D
S
S
D
V
D
A
U
X
BASS
EXTRA
VOL
1
4
7
*
2
5
8
0
3
6
9
ENT
TREB
OFF
MC-5000
Room 3
F
1
F
2
A
M
C
D
1
C
D
2
D
S
S
D
V
D
A
U
X
BASS
EXTRA
VOL
1
4
7
*
8
0
2
5
3
6
9
ENT
TREB
OFF
MC-6000 Room 4
ISO-232
RS-232 ADA BUS
Normal
Reverse
(TuneBase)
1 2 3 4
ISO-232
RS-232 ADA BUS
Normal
Reverse
(TuneBase)
1 2 3 4
ISO-232
ADA Bus To
RS-232 Converter
CMB
ADA Bus
Clock Module
Video
In 1
75
Ω
Hi-Z
H.F. Trim
Cat-Link 1
Gain Trim
Video
In 2
75
Ω
Hi-Z
Video
In 3
75
Ω
Hi-Z
H.F. Trim
Cat-Link 2
Gain Trim
H.F. Trim
Cat-Link 3
Gain Trim
Video
In 4
75
Ω
Hi-Z
Video
In 5
75
Ω
Hi-Z
Video
In 6
75
Ω
Hi-Z
H.F. Trim
H.F. Trim
Cat-Link 5
Gain Trim
H.F. Trim
Cat-Link 4
Cat-Link 6
Gain Trim
Gain Trim
Video
In 7
75
Ω
Hi-Z
Video
In 8
75
Ω
Hi-Z
H.F. Trim
Cat-Link 7
Gain Trim
H.F. Trim
Cat-Link 8
Gain Trim
WH-6000
Tx
Rx
Bus Power
ADA Bus
+V Tx Rx Gnd
4 3 2 1
RJ-45 Cat-Link
8 7 6 5 4 3 2 1
In
Loop
Out
I/O 1
I/O 2
I/O 3
Cat-Link 1 Out
Cat-Link 2 Out
Cat-Link 3 Out
Cat-Link 4 Out
Cat-Link 5 Out
Cat-Link 6 Out
Cat-Link 7 Out
Cat-Link 8 Out
WH-6000
Video Wire
Harness
Use Standard
Cat. 5
- 35 -
F
1
F
2
A
M
C
D
1
C
D
2
D
S
S
D
V
D
A
U
X
BASS
EXTRA
VOL
1
4
7
*
8
0
2
5
3
6
9
ENT
TREB
OFF
MC-6000 Room 5
Video Output (75
Ω)
RJ-45 Cat-Link
8 7 6 5 4 3 2 1
H.F. Gain Pull Shunting Pin
For Hi-Z Input
TV-6000
Cat-Link Video Receiver
Cat-Link Video Input
(From WH-6000)
To TV
Room 6
TV-6000
CMB-1 Clock Module
The CMB-1 Clock Calendar Module is a master clock module which calibrates all system clocks (i.e. MC-
5000 Keypads) on power up and from then on, every hour. While typically powered by the ADA Bus, the
CMB-1 also features a battery backup to maintain time during power outages. The CMB-1 will permit the MC-
6000, MC-5000, MC-3000 OD, and/or MC-3800 OD keypads to display the date and time when a room is off. In order for these keypads to display the time, a single CMB-1 needs to be connected to an open
ADA Bus jack on any wire harness.
ADA
Bus
SWITCH NO.
19,200 BAUD
1,200 BAUD
CMB-1
4
3
2
1
1
U P
D N
SWITCH NO.
2
24 HOUR MODE U P
12 HOUR MODE D N
SWITCH NO.
3
DAYLIGHT AUTO U P
DAYLIGHT OFF D N
Daylight Savings
Time in Auto Mode is
SWITCH NO.
4 based on US Daylight
Savings Time.
TEST MODE
NORMAL MODE
U P
D N
Test Mode On will send the time every minute. After testing, set the switch to Normal Mode.
Red LED Flashes
CMB-1 is working.
CMB-1 Open
Green LED is the power LED.
The CMB-1 features DIP switches which set the
Baud Rate (baud rates are either 1200 or 19200 and must match the settings of the Suite 16 System, typically 19200), the time mode (12 hour or
24 hour used only during test and setup mode),
Day Light Savings Time On or Off (US DST), and a test mode. As the CMB-1 features a calendar it is capable of changing the from Standard Time to
Day Light Savings Time automatically. Only one
CMB-1 is used per system.
3V (BR2032) BATTERY
Jumper Pin when pulled, removes battery from circuit, extending its life during extened storage. Jumper pin must be in place for battery to work.
WH 2000
Video
In 1
75 Ω
Hi-Z
H.F. Trim
Cat-Link 1
Gain Trim
Video
In 2
75 Ω
Hi-Z
Video
In 3
75 Ω
Hi-Z
Video
In 4
75 Ω
Hi-Z
H.F. Trim
Cat-Link 2
Gain Trim
H.F. Trim
Cat-Link 3
Gain Trim
H.F. Trim
Cat-Link 4
Gain Trim
Video
In 5
75 Ω
Hi-Z
H.F. Trim
Cat-Link 5
Gain Trim
Video
In 6
75 Ω
Hi-Z
Video
In 7
75 Ω
Hi-Z
Video
In 8
75 Ω
Hi-Z
H.F. Trim
Cat-Link 6
Gain Trim
H.F. Trim
Cat-Link 7
Gain Trim
H.F. Trim
Cat-Link 8
Gain Trim
WH-6000
Tx
Rx
Bus Power
ADA Bus
+V Tx Rx Gnd
4 3 2 1
RJ-45 Cat-Link
8 7 6 5 4 3 2 1
In
Loop
Out
I/O 1
I/O 2
I/O 3
Cat-Link 1 Out
Cat-Link 2 Out
Cat-Link 3 Out
Cat-Link 4 Out
Cat-Link 5 Out
Cat-Link 6 Out
Cat-Link 7 Out
Cat-Link 8 Out
F
M
1
F
M
2
A
M
C
D
1
C
D
2
D
S
S
D
V
D
A
U
X
BASS
EXTRA
VOL *
1
4
7
2
5
8
0
3
6
9
ENT
TREB
OFF
MC-6000 Room 4
F
M
1
F
M
2
A
M
C
D
1
C
D
2
D
S
S
D
V
D
A
U
X
BASS
EXTRA
VOL *
1
4
7
2
5
8
0
3
6
9
ENT
TREB
OFF
MC-6000 Room 5
To TV
Room 6
If it is preferable for some rooms to have the keypad’s display turn off rather than continuously display room status or time, these keypads can be individually set to blank out (Blanking On/Off), permitting others to display status or date/time. Date/ time are displayed only when the room is off or the entire system is off.
WH-6000
Video Wire
Harness
Use Standard
Cat. 5
Video Output (75 Ω)
RJ-45 Cat-Link
8 7 6 5 4 3 2 1
H.F. Gain
Pull Shunting Pin
For Hi-Z Input
TV-6000
Cat-Link Video Receiver
Cat-Link Video Input
(From WH-6000)
TV-6000
If the CMB-1 battery is dead and the system suffers a power loss, the keypads will display CHECK
BATT/TIME after all controls have been updated.
This display will continue every hour until the clock has been set.
- 36 -
MC-5011 Keypad Setup
The MC-5011 Keypad combines both elegance, function, and price into a single-gang Decora bezel.
The MC-5011 is only available with a Cat-Link connector. As such, the MC-5011 must be wired on standard Cat. 5 cable. The MC-5011 controls the Suite 16 System. You must use the WH-2000 Wiring Harness with the MC-5011 Keypad. There are eight standard pre-made source formats which are listed below.
Format 1
Format 2
Format 3
Format 4
Format 5
Format 6
Format 7
Format 8
FM1,FM2,AM,CD1,CD2,DSS,DVD,AUX
FM1,FM2,AM,CD1,CD2,CD3,DSS,DVD
FM1,FM2,AM,CD1,CD2,DSS,DSS,AUX
FM1,FM2,FM3,CD1,CD2,DSS,DVD,AUX
FM1,FM2,FM3,CD1,CD2,CD3,DSS,DVD
FM1,FM2,FM3,CD1,CD2,DSS,DSS,AUX
FM1,FM2,CD1,CD2,DSS,DSS,DVD,AUX
FM1,FM2,CD1,CD2,DSS,DSS,AUX,AUX
FM1
AM
CD2
DVD
FM2
CD1
DSS
AUX
VOL
Custom formats are also available at an additional charge. Please note, that custom formats utilize a rubber button pad where the eight source buttons are black and the lettering is etched clear. All
OFF other keypad buttons are clear with black lettering ADA then etches away the desired source label using a process that involves a laser.
Up to three characters can be used to describe a source name. This process is functional but the letters are not as smooth as those of the eight more common formats listed above. Again, the letters in a custom rubber are clear and the area around them is black. This only applies to the eight source buttons. ADA suggests using one of the eight formats listed above.
The MC-5011 features a bank of twelve DIP Switches. Switches 1 and 2 determine system model. Switch 3 sets baud rate (1200,19200), Switch 4 sets light dimming, Switch 5, 6, and 7 set source control, and switches 8, 9, 10, 11, and 12 set room number. There are also two jumper “shunting pins” that determine if the MC-5011’s IR receiver is on or off. The second
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
1 2
ON
OFF
ON
OFF
ON
0 F F
ON
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
1 1
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
1 0
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
8
ON
ON
ON
ON
ON
ON
ON
DIP SWITCH #
ROOM 1
ROOM 2
ROOM 3
ROOM 4
ROOM 5
ROOM 6
ROOM 7
ROOM 8
ROOM 9
ROOM 10
ROOM 11
ROOM 12
ROOM 13
ROOM 14
ROOM 15
ROOM 16
ROOM 17
ROOM 18
ROOM 19
ROOM 20
ROOM 21
ROOM 22
ROOM 23
ROOM 24
ROOM 25
ROOM 26
ROOM 27
ROOM 28
ROOM 29
ROOM 30
ROOM 31
ROOM 32
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
9
ON
ON
ON
ON
ON
ON
ON jumper turns the LED’s off when the system is off. With jumper is set to night mode, when the room is on, the keypad functions as normal: the selected source is red, while all other buttons are green. When the room is off but the system is still on elsewhere, all buttons are off with the exception of the OFF button, which will glow red, indicating the system is still on somewhere. When the system is off, all buttons are off. These charts will assist in properly setting up the MC-
5011.
DIP SWITCH #
DELTA @ 1200
DELTA @ 19200
MILLEN @ 1200
1
OFF
OFF
ON
MILLEN @19200 ON
SUITE 16 @ 1200 ON or OFF
SUITE 16 @19200 ON or OFF
2
OFF
OFF
OFF
OFF
ON
ON
DIP SWITCH #
SETTING 1
SETTING 2
SETTING 3
SETTING 4
SETTING 5
SETTING 6
5
ON
ON
ON
ON
OFF
OFF
6
ON
ON
OFF
OFF
ON
ON
7
ON
OFF
ON
OFF
SOURCE CONTROL OPTIOINS
IRL-3000 SOURCES 1-8 CORRESPOND TO SOURCES 1-8
TRINITY TUNER SOURCES 1-3, IRL-3000 SOURCES 4-8
TRINITY SOURCES 1-3, SPECIAL CD 1 SOURCE 4, IRL SOURCES 5-8
OFF TRINITY SOURCES 1-3, SPECIAL CD 1 & 2 SOURCES 4 & 5, IRL SOURCES 6-8
ON TRINTIY SOURCES 1 & 2, IRL-3000 SOURCES 3-8
TRINITY SOURCES 1 & 2, SPECIAL CD SOURCE 3, IRL-3000 SOURCES 4-8
SETTING 7
SETTING 8
OFF
OFF
OFF
OFF
ON
OFF
TRINITY SOURCES 1 & 2, SPECIAL CD 1 & 2 SOURCES 3 & 4, IRL SOURCES 5-8
IRL-3000 SOURCES 1-3 & 5-8, SPECIAL CD 1 SOURCE 4
IRL-3000 PORTS 1-8 ALWAYS CORRESPOND TO SOURCES 1-8. SPECIAL CD IS USED WITH AQUARIUS & ESCIENT PRO MK II/III
3
ON
OFF
ON
OFF
ON
OFF
- 37 -
MC-5000 Keypad LED Setup
The MC-5000 Rapture Keypad is designed to permit you to select different light colors per button groups.
The buttons are grouped together by function and each group has three DIP switches associated to that group. The three switches turn on red, green, and blue individually. These switches are found on the circuit board attached to the MC-5000 wall plate.
There are two banks of 12 switches, 24 switches total, for eight button groups.
The eight groups are: Numerics, Transports, Sources
Not Selected, Source Selected, Bass & Treble (Party
1 & 2 on Millennium), Extra, Volume, and Off.
F
M
1
F
M
2
A
M
C
D
1
C
D
2
D
S
S
D
V
D
A
U
X
BASS TREB
EXTRA
VOL *
1
4
7 8
0
2
5
3
6
9
ENT
Available Colors Include: Red, Green Blue, Purple
(Red & Blue On), Orange (Green & Red On), Light
Blue (Blue & Green On), White/Pink (Red, Green & Blue On), and No Color (All Off).
OFF
To set the colors, ADA suggests taking an ordinary paper clip and creating a small tool that will allow you to turn the switches on and off as you desire.
Open the paper clip so that one end is extended straight. Using a needle-nose set of pliers, bend the end of the tip so that the extended end has a little hook to it.
As some of the DIP switch groups are hard to access, in particular Source Used and
Sources Not Used, this paper clip will be of use.
G
B
R
G
B
R
R
G
B
R
G
B
ON
SOURCE
USED
SOURCES
NOT USED
BASS/TREB
PARTY 1&2
TRANSPORT
EXTRA VOL OFF NUMER
ON
1 2 3 4 5 6 7 8 9 10 11 12
R G B R G B R G B R G B
- 38 -
MC-5000 Keypad Manual Setup
The EXTRA button is used to both permit the user to access other keypad functions while permitting the installer to enter the keypad’s program mode.
To enter the program mode, press and hold the EXTRA button for 5 seconds. The display will read the keypad’s version number followed by the enter code display:
CODE: _ _ _ _
Enter the ADA code number using the eight source buttons where the source button on the far left refers to the number 1 and the source button on the far right refers to the number 8.
The following codes activate the associated menu functions.
CODE
1111
1112
1113
1115
1116
1117
1118
1867
MENU FUNCITON
TEST KEYS
IR ON/OFF TOGGLE
DESCRIPTION
DEMONSTRATION KEYPAD MODE
TURNS KEYPAD IR RECEIVER ON & OFF
DISPLAY BLANK TOGGLE WHEN THE SYSTEM IS OFF, THE KEYPAD DISPLAY BLANKS OUT AFTER A SHORT TIME.
CLOCK SETUP SET DATE AND TIME
ROOM NUMBER
BAUD RATE 1200
SETS ZONE KEYPAD ZONE NUMBER
SETS KEYPAD BAUD RATE TO 1200 BAUD
BAUD RATE 19200
INSTALLER MODE
SETS KEYPAD BAUD RATE TO 19200 BAUD
SETS KEYPAD INTO PROGRAM MODE
After entering the code the display will confirm the setup mode selected.
For Code 1111, the display will read TEST KEYS. As sources are selected, the selected source button will illuminate the active LED color while the rest of the keypad LEDs will light up. Upon press the source buttons, the following characters will be displayed on the twelve character display. Pressing the Room Off button will turn off the source
LED’s. Pressing the Extra button will indicate EXTRA and then the keypad will exit the Test Keys mode and return to normal operation.
IR Receiver On/Off Toggle
For Code 1112, the display will read IR ON or IR OFF depending on the state of the IR. Re-entering this code will reverse the process.
Keypad Display Time Out - Bedroom Mode
For Code 1113, the display will read BLANKING ON or BLANKING
OFF, depending on the state of the readout display. Display will black out after 5 seconds after receiving a feedback update.
Room Address
For Code 1116, the display will read the current room number:
SET ROOM # (where the # is the current room number)
BUTTON
SOURCE 1
SOURCE 2
SOURCE 3
SOURCE 4
SOURCE 5
SOURCE 6
SOURCE 7
SOURCE 8
BASS UP
BASS DN
TREB UP
TREB DN
VOL UP
VOL DN
*
ENTER
>>
<<
>
<
STOP
PAUSE
7
8
5
6
9
0
3
4
1
2
DISPLAY
FM TUNER 1
FM TUNER 2
AM
CD PLAYER 1
CD PLAYER 2
DSS RECEIVER
DVD PLAYER
AUXILIARY
BASS UP
BASS DOWN
TREBLE UP
TREBLE DOWN
VOLUME UP
VOLUME DOWN
1
4
5
2
3
*
ENTER
FAST FORWARD
REWIND
PLAY
REVERSE
STOP
PAUSE
8
9
6
7
0
To change the room number of the keypad, use the >> or <<. Room numbers will increment between 1 and 99. Press EXTRA to exit the setup mode and the display will momentarily read ROOM = # and then the display will return to normal operation.
- 39 -
1200 Baud Rate
For Code 1117, the display will read BAUD 1200. If the display maintains BAUD 1200, the keypad is not communicating with the Suite 16. As such, this may be the wrong baud rate setting.
19200 Baud Rate
For Code 1118, the display will read BAUD 19200. If the display maintains BAUD 19200, the keypad is not communicating with the Suite 16. As such, this may be the wrong baud rate setting.
Clock and Calendar (This function only works if the control is connected to a system that includes the CMB-1 Clock Calendar Module. The CMB-1 must be on the bus.)
For Code 1115, the display will read CLOCK SET. Use the < or > buttons to select which of the following parameters you wish to change.
SET HOURS.-SET MINUTES-SET MONTH-SET DATE-SET DAY-SET 12-24 HR-SET YEAR
The SET 12-24 HR function refers to the clock displaying time in 12 hour mode or 24 hour mode. This setting is independent of that on the CMB-1 and is set locally. As such, some keypads can display time in 12 hour mode while others display time in 24 hour mode.
Regarding the setting of seconds, any adjustment to minutes resets the seconds to zero.
All changes are accepted immediately.
SET HOURS - When you navigate to the SET HOUR display using the < or > buttons, pressing the << or >> button only once, will cause the display to read the current state without changing any of the settings, as an example:
FEB14 23:33 or FEB14P11:33
(“P” stands for p.m. when in 12 hour mode. No character is displayed for a.m.)
While the keypads can be set to display either 12 or 24 hour modes independently of the setting of the CMB-1, during time/date setup, the CMB-1’s 12/24 hour mode setting will dominate the display. Use the >> or << to alter the hour. If in 24 hour mode (set 12 or 24 Hour mode using DIP switches on the CMB-1), the time will increment through 24 hours. If in the
12 hour mode, the clock will display “P” for p.m.
SET MINUTES - After setting the hour, use the > button to advance the display to SET MIN-
UTES and then press << or >> once. Again the display will read the current date and time, as an example, FEB14 23:33. At this time, pressing >> or << will advance or decline through minutes. When the desired time is displayed, use the > button to advance to:
SET MONTH - After setting the minutes, use the > button to advance the display to SET
MONTH and then press << or >> once. Again the display will read the current date and time, as an example, FEB14 23:33. At this time, pressing >> or << will advance or decline through the twelve month. When the desired month is displayed, use the > button to advance to:
- 40 -
SET DATE - After setting the month, use the > button to advance the display to SET DATE and then press << or >> once. Again the display will read the current date and time, as an example, FEB14 23:33. At this time, pressing >> or << will advance or decline through the numeric date. When the desired date is displayed, use the > button to advance to:
SET DAY - After setting the date, use the > button to advance the display to SET DAY and then press << or >> once. The display will read the current day, as an example, THU. At this time, pressing >> or << will advance or decline through the seven days. When the desired day is displayed, use the > button to advance to:
SET 12-24 HR - After setting the day, use the > button to advance the display to SET 12-24
HR and then press << or >> once. The display will read 12 HOUR MODE or 24 HOUR
MODE. At this time, pressing >> or << will switch between these two options. While all other features are loaded into the CMB-1, thus not requiring you to do this process for each and every keypad, the 12/24 display setting must be altered on a per keypad basis. This is the only Clock/Calendar associated setting that is not global. When the desired clock mode is displayed, use the > button to advance to:
SET YEAR - After setting the 12/24 hour mode, use the > button to advance the display to
SET YEAR and then press << or >> once. The display will read the current year, as an example, 2002. At this time, pressing >> or << will advance or decline through the available years (2000-2099). For systems that are still operational in 3000, ADA will suggest upgrading the MC-5000 software. When the desired month is displayed, use the > button to advance back to SET HOURS or press the EXTRA button to exit this setup mode.
Exiting the Clock/Calendar Setup
If you wish to exit this setup mode at any given time, press the EXTRA button.
MC-5000 Installer Setup
Unlike the previous setup features, those found under Installer Setup are more involved to the systems underlying programming. It is here, that the feature set of the MC-5000 when used with the Suite 16 System is fully realized. Prior to entering the code the Version # will appear.
To enter the installer area, press and hold the extra button until the display reads:
CODE __ __ __ __
Enter the code “1867” using the source buttons where the number one is the first source on the left while the number eight is the last source, that on the far right. When the code is entered correctly, the display will read:
INSTALLER
The first stage of this sequence is the connection of the keypad’s eight source buttons to the
16 inputs on the Suite 16. Pressing the >> or << buttons will advance through these options:
INPUT CONFIG - SOURCE CNTRL - SOURCE LABEL - CHECK SETUP - PROGRAM ALL
- 41 -
Input Configuration
While the display reads INPUT CONFIG pressing the > button will engage the input configuration mode. The display will read:
NORMAL INPUT
Here there are a total of five options, the most common of which the normal input configuration option is the most common:
NORMAL INPUT - PARTYGROUP 1 - PARTYGROUP 2 - PARTY GROUP 3 - PARTYGROUP 4
By pressing >> or <<, you will be able to advance through the above five options. Again, pressing < will return you to the previous level. When you have selected one of the above options, such as NORMAL INPUT, press the > button. The display will then read the first input option:
INPUT 0
Pressing >> or << buttons will scroll through all of the seventeen options under the headings found in the table below. To return to the previous level, press the < button.
NORMAL INPUT PARTYGROUP 1 PARTYGROUP 2 PARTYGROUP 3 PARTYGROUP 4
INPUT 0 PTYGRP1-IN 0 PTYGRP2-IN 0 PTYGRP3-IN 0 PTYGRP4-IN 0
INPUT 1
INPUT 2
PTYGRP1-IN 1
PTYGRP1-IN 2
PTYGRP2-IN 1
PTYGRP2-IN 2
PTYGRP3-IN 1
PTYGRP3-IN 2
PTYGRP4-IN 1
PTYGRP4-IN 2
INPUT 3
INPUT 4
INPUT 5
INPUT 6
PTYGRP1-IN 3
PTYGRP1-IN 4
PTYGRP1-IN 5
PTYGRP1-IN 6
PTYGRP2-IN 3
PTYGRP2-IN 4
PTYGRP2-IN 5
PTYGRP2-IN 6
PTYGRP3-IN 3
PTYGRP3-IN 4
PTYGRP3-IN 5
PTYGRP3-IN 6
PTYGRP4-IN 3
PTYGRP4-IN 4
PTYGRP4-IN 5
PTYGRP4-IN 6
INPUT 7
INPUT 8
INPUT 9
INPUT 10
INPUT 11
INPUT 12
INPUT 13
INPUT 14
INPUT 15
INPUT 16
PTYGRP1-IN 7
PTYGRP1-IN 8
PTYGRP1-IN 9
PTYGRP1-IN10
PTYGRP1-IN11
PTYGRP1-IN12
PTYGRP1-IN13
PTYGRP1-IN14
PTYGRP1-IN15
PTYGRP1-IN16
PTYGRP2-IN 7
PTYGRP2-IN 8
PTYGRP2-IN 9
PTYGRP2-IN10
PTYGRP2-IN11
PTYGRP2-IN12
PTYGRP2-IN13
PTYGRP2-IN14
PTYGRP2-IN15
PTYGRP2-IN16
PTYGRP3-IN 7
PTYGRP3-IN 8
PTYGRP3-IN 9
PTYGRP3-IN10
PTYGRP3-IN11
PTYGRP3-IN12
PTYGRP3-IN13
PTYGRP3-IN14
PTYGRP3-IN15
PTYGRP3-IN16
PTYGRP4-IN 7
PTYGRP4-IN 8
PTYGRP4-IN 9
PTYGRP4-IN10
PTYGRP4-IN11
PTYGRP4-IN12
PTYGRP4-IN13
PTYGRP4-IN14
PTYGRP4-IN15
PTYGRP4-IN16
Input 0 or any of the party group inputs that read 0 refer to no source selection at all. These options are useful to prevent a source button from selecting anything on that button (i.e. a source button that does nothing).
To lock a keypad’s source button into one of the above inputs, press the source button while the keypad displays the corresponding input setting. The keypad will echo INPUT OK while the source button pressed will illuminate, indicating that the setting has been locked in. If you have a 0 input setting displayed and you then press a source button, the display will indicate
NO INPUT OK. Continue setting all eight source buttons. To return to a previous level, press the < button. To return to the main Installer area, press the < button again.
- 42 -
Party Group Source Selection
The Party Group source selection feature permits multiple rooms to engage to the selected source when a single keypad accesses that source. This feature is used to setup “party” type sources in several rooms when entertaining. In this application, not all sources on a keypad need be set to party. In fact, the keypads in the zones set to party, might not have a single party function on them. Perhaps only one keypad, (i.e. kitchen), might have a single button
(i.e. CD1) that will cause the living room, dining room, and entry foyer to engage to CD with the kitchen. Here the kitchen CD1 button will need to access a Party Input which would be programmed on that keypad’s button as illustrated on the previous page. The three other rooms would need to be programmed to track that specific party group using ADA’s Suite 16 setup software (PC based software).
The Party Group source selection function is also used to make certain that several zones turn on together and continuously track the same source. For example, if a living room, dining room, and entry foyer require independent volume, bass and treble settings, they need to be each their own zone. However, if these three areas are open to each other, there may be a desire to prevent different sources from ever playing simultaneously in these zones/rooms.
As such, these rooms can be set to turn on together but never play a different source. To do so, one of the Suite 16’s four Party Groups will need to be dedicated to this group of zones/ rooms. Each of the rooms keypads will need to be programmed so that the source buttons on these keypads engage sources specific to that party group. Finally, in software, using the
ADA Suite 16 PC Software, all these zones/rooms will need to be set to the corresponding party group.
Exiting Input Configuration
To exit the Input Configuration mode from the deepest level, press the < button to return from the INPUT # to the NORMAL INPUT level. Press the < again to return to INPUT CONFIG and following options:
NORMAL INPUT - PARTYGROUP 1 - PARTYGROUP 2 - PARTY GROUP 3 - PARTYGROUP 4
Source Control
To advance to the SOURCE CNTRL option press the << or >> button until the display reads:
SOURCE CNTRL
Then press the > button. The display will read IR LEARNER. To advance to one of the following, press the >> or << buttons. To return to the previous level, press the < button.
IR LEARNER - ADA TUNER - SPECIAL CD - LVI - NO FUNCTION
The above five options refer to the various source control options that are built into the MC-
6000 keypad. By moving the >> or << so that the display reads IR LEARNER, you are ready to lock in sources to an IR LEARNER port. Press > to select the IR LEARNER while it is displayed.
The NO FUNCTION permits you to have a source button perform no transport functions at all. To do this, while NO FUNCTION is displayed, press the source button. The display will confirm NONE OK.
- 43 -
IRL-5000
Once you press the > button while IR LEARNER is displayed, the display will change to read:
IRL ADDRESS1
Using the >> and << buttons, you can advance through the following options. Use the < button to return to the previous level.
IRL ADDRESS1 IRL ADDRESS2 IRL ADDRESS3 IRL ADDRESS4 IRL ADDRESS5 IRL ADDRESS6 IRL ADDRESS7 IRL ADDRESS8 IRL ADDRESS9
While the display reads IRL ADDRESS1, pressing the > button will take you to the next level where the display will read:
IRL 1 OUT 1
To lock this IRL-5000 output port number to a specific source, press the source button. The display will confirm IRL OK and return to the above setting. To advance to other IRL-5000 port outputs on an IRL-5000 with the like address, use the >> or << buttons. The options listed below will be scrolled through.
IRL1 OUT1 - IRL1 OUT2 - IRL1 OUT3 - IRL1 OUT4 - IRL1 OUT5 - IRL1 OUT6 - IRL1 OUT7 - IRL1 OUT8
Again, once a desired output port is displayed, press the corresponding source button. The display will indicate IRL OK to verify the selection. As always, use the < button to return to the previous level. If the wish to exit the IRL-5000 from this level, you will need to hit the < button twice. The first time will return you to the IRL ADDRESS1 stage and the second time to the IR learner stage where the display will again read IR LEARNER.
ADA Tuner
To advance to the ADA Tuner, use the >> or << buttons. When the display reads:
ADA TUNER
Press the > button to enter this option. The display will read:
TUNER ADRS 1
Using the >> or << buttons, you can scroll to the address of the Tuner (this is not the module output number). Typically, Address 1 is the default address used and should not be changed.
Unless you changed the address, when the display reads TUNER ADRS1, press the > button. The display will then read:
TUNER1-OUT1
To return to the previous level, press <. To advance to other Tuner Module Outputs, use the
>> or << buttons.
TUNER1-OUT1 TUNER1-OUT2 TUNER1-OUT3
To engage a particular Tuner Module Output, press the corresponding source button. The keypad will respond TUNER OK, indicating that the source button will now track this output.
- 44 -
Exiting Trinity Tuner Setup
To exit the Trinity Tuner from the lowest level, you will need to press the < button twice. The first time will return you to the address level, the second time will return you to ADA TUNER with the following options available.
IR LEARNER - ADA TUNER - SPECIAL CD - LVI - NO FUNCTION
Using the >> or << buttons, you can proceed to Special CD or LVI. By pressing the < button you can return to the primary menu level which includes the following:
INPUT CONFIG - SOURCE CNTRL - SOURCE LABEL - CHECK SETUP - PROGRAM ALL
Special CD
To engage a special CD setting, you must first be certain that you have a component that specifically operates on ADA Special CD commands. ADA’s Aquarius Hard Drive, Escients
Tunebase Pro Mk II and III, or Media Access Solutions Hard Drive players are embedded with the Special CD command sets.
To navigate to this setting, make certain you are in the SOURCE CNTRL level and using the
>> or << buttons, advance until the display reads:
SPECIAL CD
Then press >. The display will read:
SPECIAL CD 1 were as many as eight options exist including the following:
SPECIAL CD 1 SPECIAL CD 2 SPECIAL CD 3 SPECIAL CD 4 SPECIAL CD 5 SPECIAL CD 6 SPECIAL CD 7 SPECIAL CD 8
To lock a source button to track one of the special cd options, press the source button while the display shows the corresponding Special CD address number. The display will confirm
CD OK. To advance to an alternate address setting, press the >> or << button. To return to the previous level, press the < button.
LVI-3800
The LVI-3800 is a low voltage relay control device that provides up to seven contact closures corresponding to a keypads: >, <, >>, <<, stop, pause, and main buttons. It is useful for controlling devices that lack either an IR or RS-232 control interface. To lock a source button to control the LVI-3800, make certain that you are in the SOURCE CNTRL. Use the >> or << buttons to navigate until the display reads:
LVI
Press > to enter the LVI menu and the display will read LVI 1 with eight possible options. Use the >> or << buttons to advance between these options LVI 1 through LVI 8. When the desired LVI address is displayed, press the source button and the keypad will confirm LVI OK.
To exit this level, press the < button.
No Function
When NO FUNCTION is displayed, pressing a source button will cause that source’s transport buttons to have absolutely no source control. The display will confirm NONE OK.
- 45 -
Source Labels
Source Labels are the names of the sources that are connected to the Suite 16. While the keypad buttons have only a few buttons to designate a source name, the keypad’s display can read up to eleven characters. This permits you to better define that component. Whether you are using eight or less sources, more than eight, or the full sixteen sources on a Suite 16
System, the keypads need to be programmed with all sixteen input names. By default, inputs
9-16 are pre-labeled in the keypads as INPUT 9 through INPUT 16.
INPUT CONFIG - SOURCE CNTRL - SOURCE LABEL - CHECK SETUP - PROGRAM ALL
To do so, while in the setup mode above, use the >> or << buttons until the display reads:
SOURCE LABEL
Then press the > button. The display will offer two options:
STNDRD LABEL or CUSTOM LABEL
Where the display will read
STNDRD LABEL
Then press >. The display will read
FORMAT 1
Using the >> or << buttons will advance through the following alternatives.
FORMAT 1 FORMAT 2 FORMAT 3 FORMAT 4 FORMAT 5 FORMAT 6 FORMAT 7 FORMAT 8
The table below shows the labels associated with the options selectable above.
Format 1
Format 2
Format 3
Format 4
Format 5
Format 6
Format 7
Format 8
Input 1
FM TUNER 1
FM TUNER 1
FM TUNER 1
FM TUNER 1
FM TUNER 1
FM TUNER 1
FM TUNER 1
FM TUNER 1
Input 2
FM TUNER 2
FM TUNER 2
FM TUNER 2
FM TUNER 2
FM TUNER 2
FM TUNER 2
FM TUNER 2
FM TUNER 2
Input 3
AM TUNER
AM TUNER
AM TUNER
FM TUNER 3
FM TUNER 3
FM TUNER 3
CD PLAYER 1
CD PLAYER 1
Input 4
CD PLAYER 1
CD PLAYER 1
CD PLAYER 1
CD PLAYER 1
CD PLAYER 1
CD PLAYER 1
CD PLAYER 2
CD PLAYER 2
Input 5
CD PLAYER 2
CD PLAYER 2
CD PLAYER 2
CD PLAYER 2
CD PLAYER 2
CD PLAYER 2
DSS 1
DSS 1
Input 6
DSS
CD PLAYER 3
DSS 1
DSS
CD PLAYER 3
DSS 1
DSS 2
DSS 2
Input 7
DVD PLAYER
DSS
DSS 2
DVD PLAYER
DSS
DSS 2
DVD PLAYER
AUXILIARY 1
Input 8
AUXILIARY
DVD PLAYER
AUXILIARY
AUXILIARY
DVD PLAYER
AUXILIARY
AUXILIARY
AUXILIARY 2
Input 16
INPUT 16
Input 9
All Formats INPUT 9
Input 10
INPUT 10
Input 11
INPUT 11
Input 12
INPUT 12
Input 13
INPUT 13
Input 14
INPUT 14
Input 15
INPUT 15
To select an option use the >> or << buttons to navigate to the Option Number and then press the > button. That label set will be applied to the first eight sources. The display will read
LABEL OK.
To exit the standard format option level, press the < button. The display will return to STNDRD
LABEL with the following options.
STNDRD LABEL CUSTOM LABEL
- 46 -
To completely exit the Source Label area, press the < button. To customize source labels for either the first eight or all sixteen source labels, use the >> or << buttons until the display reads:
CUSTOM LABEL
Then press the > button. The display will read the first of sixteen inputs.
INPUT 1
Using the >> or << buttons, you can navigate through all 16 source inputs. When the display is on an input whose label you wish to alter, press the > button. The first character will blink on the selected label.
You have two options here, a character by character changing of the label and/or a selection from a pre-made source label list. Use the VOL UP or VOL DN buttons to access the 41 premade options. Use the STOP and PAUSE buttons to change the blinking character. When done, use the >> or << buttons to advance the cursor to the next or previous character.
Repeat this until the display reads the name as you wish it to appear. Press > to lock in changes and the display will confirm LABEL OK.
To change other input source labels, use the < button to return to the previous input label level. Here, you can use the >> or << buttons to navigate to a different input. Again, press > to edit this label. To completely exit the source label menu, press the < button until the display reads CUSTOM LABEL. Then press the < button once more to return to the main setup menu with the options shown below.
INPUT CONFIG - SOURCE CNTRL - SOURCE LABEL - CHECK SETUP - PROGRAM ALL
Check Setup
When CHECK SETUP is displayed, press the > to verify keypad source buttons to input numbers, source labels, and source control settings for that input. Select the source and the display will cycle between these three settings. To step back to the previous level, press the
< button.
Program All
Program All takes the information, including keypad source buttons to input assignments, source control assignments, and source labels and uploads them to all other keypads currently on the ADA Bus. If you have some keypads currently on the ADA Bus that are custom programmed, you will want to disconnect them because the Program All function will load them with the programming that is internal to the keypad that is initiating the Program All. To program other keypads, use the >> or << buttons to navigate through the following
INPUT CONFIG - SOURCE CNTRL - SOURCE LABEL - CHECK SETUP - PROGRAM ALL until the display reads: PROGRAM ALL
Then press the > button. UPLOAD READY To abort, press the < button.
To begin the upload, press the > button. The keypad that is uploading will display UPLOAD-
ING. The keypads being programmed will read PROGRAMMING. When the programming is complete, the keypad will exit the Installer Mode and the displays will read UPLOAD DONE and PROGRAM DONE respectively.
- 47 -
RS-232 Connections for PC’s & Control Systems
The AVP-16 chassis features two RS-232 ports, one on the front of the chassis and a second one on the rear panel. These two RS-232 ports are in parallel. As such only one port can be used at any one time. If you have a PC or external control system connected to the rear panel
RS-232 port, the front panel port will not be functional. The same is true if you have the front port active, then the rear panel port will not be active.
Ideally, you want to leave either the front panel (or perhaps the rear panel) port available for connection of a PC. This will permit you to connect your lap top PC to the Suite-16 System so that you can use the two following PC based programs, the Keypad Uploader and Suite 16
Tester.
The Keypad Uploader program permits you to program MC-5000, MC-6000, MC-3000, MC-
3800, MC-3000 OD and MC-3800 OD keypads without having to enter the keypads program steps. The Suite-16 Tester program is most useful for system set up. In most cases, you will need to use a PC to fully access all the feature sets of Suite 16. As such, this program and its ability to connect to the AVP-16 is essential.
Communication Settings
While the baud rate on the Suite 16 is adjustable between 1200 and 19200 baud, the typical setting used is 19200 baud. Other settings are 8 Data Bits, 1 Stop Bit, & No Parity.
ISO-232 & External Control Systems
If you are also controlling the Suite 16 System from an external control system (i.e. AMX or
Crestron), ADA strongly suggests adding an
ISO-232 to the system. In addition to leaving either the front or rear panel RS-232 jack open for your PC, the ISO-232 provides electrical isolation that is not internal to the AVP-16’s RS-
232 ports. This isolation will be useful in helping to eliminate ground loops. The ISO-232 can connect directly to any open ADA Bus port on the system wire harness or if no other ADA
Bus components are used in the system, including any ADA keypads, directly into the ADA
Bus jack on the AVP-16.
POWER
AVP-16
RS-232
Use either front or rear panel RS-232 port to connect to your PC. Do not use both at same time.
L
R
L
R
1
2
1
1
3
4
2
2
5
6
3
3
8
4
4
10
5
5
7
VIDEO INPUTS
9 11
12
6
6
13
14
7
7
15
16
8
8
A-16
P-16
1
V16
2
EXPANSION PORTS
9
9
3
4
10
10
5
6
11
11
7
8
12
12
9
10
13
13
11
12
14
14
13
14
15
15
15
16
16 In 1-8
Input Triggers
In 6/14
In 5/13
In 4/12
In 3/11
In 7/15
In 8/16
Gnd
In 1/9
In 2/10
Zones 7-12 +12VDC Outputs
Output Triggers
Out 1-8
V-16 Video I/O Module
Out 6/14
Out 5/13
Out 4/12
Out 7/15
Out 3/11
Out 8/16
Gnd
Out 1/9
Out 2/10
Programmed Video
Input Triggers
Gnd
5-24V AC DC
1 2 3
(-) (+) (+) (+)
4
(+)
Out 9-16
+12VDC Outputs
A-16 Audio Input Module
Balanced Trigger
Audio Page
Input (600 )
5-24V
AC DC
1
Com
2
(+) (-)
3 4
(+)
5
(-)
16
In 9-16
+12VDC Outputs
Paging Input/Trigger
Zones 1- 6 & 7-12
Zones 1-6
In 6/12 TO PTM-1225/1260
In 5/11
In 4/10
In 3/9
Gnd
In 1/7
In 2/8
P-16 Preamplifier Module
Zones 13-16
+12VDC Output
Gnd 13 14 15 16
(-) (+) (+) (+) (+)
1/2 ASB
115V~
1/4 ASB
230V~
Input Triggers
1 Gnd
Network Control I/O
2 Fdbk
3 Cntrl
4 +V
ADA BusÆ
230V
115V
115 V
Switch
AC
(10A)
Main
AC
Input
WARNING! Risk Of Hazardous Energy!
Make Proper Connections.
AVERTISSEMENT! Energie Electrique
Dangereuse!
Faire Des Connexions Propres
Pour L'Hautparleur.
Voir La Notice De Fonctionnement.
CAUTION: Disconnect Supply
Cord Before Servicing.
ATTENTION: Debrancher
Avant Le Depannage.
115V~/60Hz 230V~/50Hz
500 WATTS MAX
CAUTION
DO NOT OPEN
ATTENTION!
RISQUE DE CHOC ELECTRIQUE.
NE PAS OUVRIR
MADE IN U.S.A.
AVP-16 MR Controller
ADA Bus to WH-2000 J1
RS-232 Cable
The connection of PC or Control System to an ADA RS-232 port requires a simple straight through 9-pin “D” style
RS-232 cable. You should not use a null-modem or cross-over cable. If you use an alternate type of cable, you will most likely not get communication, in the form of feedback or control to occur.
To RS-232 Control
System or AMX or
Crestron Control System
ISO-232
RS-232 ADA BUS
Normal
Reverse
(TuneBase)
1 2 3 4
ISO-232
ADA Bus To
RS-232 Converter
WH-2000
1 2 3 4
J1
J2
J3
J4
J5
RJ45
RJ45
RJ45
RJ45
RJ45
RJ45
RJ45
RJ45
WH-2000
- 48 -
Keypad Uploader Program (MC-5KS Uploader)
ADA’s MC-5KS Uploader program is designed to speed you through the process of programming keypad button input links, source control links, and source labels. Furthermore, you can retain a saved version of the project as a “.5KS” file type, permitting you to open the setup parameter file at future times.
To connect the PC to the system, you can use the front panel RS-232 jack on the AVP-16 providing that the rear panel RS-232 is not used. You can also connect using an ISO-232.
Use a straight-through 9-pin RS-232 cable.
After installing the Keypad Uploader program on your PC, open the program and proceed with these first steps.
Under Configuration, select your Com port and baud rate. Unless you have specifed or have purposely selected the 1200 baud rate setting for the Suite-16, the factory setting for the system is 19200. As such, in the setup software, you will need to select 19200 as well.
- 49 -
Begin by labeling your inputs. Select an input label, by default labeled 1 through 16, which will then be outlined in blue. You can label each source with only 11 characters.
- 50 -
Now select the Source button representative of the eight source buttons on ADA keypads and assign a Suite 16 Input to it.
Determine if the keypad button is a normal input or if it will activate a Suite 16 Party Group.
Finally, assign the source control option, in this example Trinity Tuner, Module 1.
- 51 -
For sources that are controlled by the IRL-5000, you can assign both an address and port.
For the Special CD option, to control and get feedback from the Aquarius Hard Drive Server, select the source button and assign a Special CD Address.
For sources that are controlled by the LVI-388 Low Voltage Relay device, assign as below.
- 52 -
Once you have the customer’s MC-5000 configuration established, you can opt to save it as a “.5KS” file type. As such you can reload these settings at a later time.
Under File, select Save As and enter a customer name with the “5KS” suffix and press save.
To upload the settings to the MC-5000 keypads, simply press the UPLOAD ALL button. The software will indicate the status of the upload as well as prompting you when it is completed.
- 53 -
Suite 16 Testing & Program
ADA has developed a fully functional PC program for the Suite-16 System, the Suite-16 Testing & Programming Software. Using this application, you can control a complete Suite-16
System. This program is also ideal for setting up a Suite-16 System, permitting you to make use of all the system features. As many of these features are set and permanently stored in the Suite-16, setup is typically a onetime procedure.
Use a straight-through 9-pin RS-232 cable when connecting to your PC or an external control system.
In order to use the PC software, you need to have your PC connected to the Suite-16. There are several options available to you. The AVP-16 features both a front panel and rear panel
RS-232 9-pin D connector. These two connectors are in parallel. As such, if another control system or PC is connected to the rear panel jack, you cannot use the front panel. The same is true if something were connected to the front panel and you desired to connect your PC to the rear panel. Only one of these two connectors can be used at any one time. As described on the previous page, if you are using an external control system and wish to, from time to time, connect a PC to the front panel jack (for service and setup), you may select to include an
ADA ISO-232 ADA Bus to RS-232 Converter to the system. The ISO-232 can be used for the external control system while the front (or rear panel) RS-232 port on the AVP-16 can be used for connection to your PC. If you do not have an ISO-232 and are using an external control system, disconnect the control system prior to connecting your PC.
ADA strongly suggests using an ISO-232 for external control systems because it provides additional electrical isolation and assists in preventing ground loops.
Configuration Page
The first page will access is the Configuration page. Here you will need to select your
Com port. The Global
Version Request button will request the version numbers of the P-16 and V-16 modules. As these cards’ programs are loaded at ADA, knowing the program release numbers will be useful if service issues arise. This page also permits you to test audio and video inputs using the Input/Output
Test area at the bottom of this page.
- 54 -
Room Control Page
Under the Room Control tab, you can set and control all of the audio parameters specific to that room.
Begin by selecting a room number using the pull-down room window.
To update the PC’s display with this room’s status, you will need to press the little square (orange/red) located in the lower left-hand corner of this window. The numeric fields for volume, maximum volume, paging volume, treble and bass will populate. Also, the existing room state will indent regarding all off, room off, or current audio input as well as turn-on option, stereo-L/R mode, tone filters on/off, party groupings and page groupings.
The image below details the entire Room Control page. Details for this page are discussed in the following pages.
- 55 -
Input Selection
There are several ways to select a source. You can simply use the input up or input down buttons. You can also directly access inputs numerically. If a room is off or if the system in all off, those buttons will be depressed. When an input is selected, the room turns on.
Bass & Treble Control
Bass and Treble are controlled in two ways, there is the standard up and down commands which will raise and lower bass and treble levels over a range from -12 to +12 with 0 being tone control flat. Tones levels are stepped numerically in two’s, from 0 to 2 to 4 etc. You can also do a bass or treble direct command which enters a value using the slider control. Much like a touch screen with sliders, the numeric tone level is jumped to as the slider is released.
Loudness & Stereo Enhancement Filters
There are two additional filters associated with tones. The loudness filter engages additional bass.
The stereo enhancement filter opens the stereo imaging of the sound stage.
Tone Presets
There are four tone presets. To store a preset for a specific bass and treble level, set the tone controls to that level and then press either one of the four tone preset store buttons. To recall a tone preset, press the corresponding recall button. Please note, that the status of the filters will also store with the tone presets. If the loudness filter was on and the stereo enhancement filter was off when preset number 2 was stored, they will return to these settings when preset number 2 is recalled. Tone preset number 1 is recalled when the zone turns on providing the zone is set to turn on to recall 1.
Balance Control
Balance is a feature of a speaker channels volume level and the range swings from Left 40 to Right 40, with the balance set to
Equal when centered between right and left channels. There are two balance presets. To store a balance preset, set the balance control to the desired level and then press one of the two store buttons. To recall the balance level, press the appropriate recall button. Balance preset number one is recalled when the zone turns on providing the zone is set to turn on to recall 1.
- 56 -
Volume Control
Volume is controlled in two ways, there is the volume up and down commands which will raise and lower volume levels over a range with 40 values (0-40). You can also do a volume direct command which enters a value using the slider control. Much like a touch screen with sliders, the numeric volume level, between 0 and
40, is jumped to as the slider is released.
Maximum Volume Level
The maximum volume level is set to prevent the room’s volume from ever extending beyond the maximum volume level. To set this level, simply position the slider at the desired position.
Mute Commands
Again, there are two options for mute. The mute on command engages mute, while the unmute command returns sound. Repeated pressing of the toggle button will switch between mute and unmute.
Volume Presets
There are four volume presets. To store a preset for a specific volume level, set the volume to that level and then press either one of the four volume preset store buttons. To recall a volume preset, press the corresponding recall button. Volume preset number 1 is recalled when the zone turns on providing that the zone is set to turn on with recall 1.
Zone Turn On Settings
When a zone turns on, it can be programmed to either turn on to its last used state or to a preset level.
To select the zone to turn on to a preset level, press the turn-on w/recall 1 button. At this time, all preset number 1 settings will be recalled when the zone turns on, including volume, balance, bass, treble and loudness and stereo enhancement filter settings.
Channel Mixing Selector
While you most likely will never have the need to engage a setting other than stereo, you do have option here to select a particular channel to play through both right and left preamplifier outputs.
By selecting mono left, both right and left channels will only play the source signal’s left input. By pressing mono right, both right and left channels will only play the source signal’s right channel information. Again, this feature can best be described as useful when listening to program material with a specific language on one channel and another language on the left channel. As this is a feature set that is not tied to any preset, it will be important to return to the stereo setting if either mono setting has been previously selected.
- 57 -
Party Grouping
Party Grouping delivers to the Suite 16 System two functional features. There are a total of four party groups. Much like a room has command sets for selection of input 1, input 2,...,input 16, each party group also has an input selection command set for input 1, input 2,...,input
16. Just like room 5 has an input selection command for source 8, party group 1 has an input selection command set for source 8.
With this in mind, we can proceed to understand how to use the party group functions. As previously mentioned, party grouping has two useful features. The first is the ability for several zones to turn on to a single source with one command. This is useful for entertaining, hence the name “party groups”. By assigning several rooms to a party group number, when an input selection is sent for this party group, all rooms on this party group engage to that source. If rooms are set to turn on to their acoustical preset, then all rooms associated with this party group, will turn on to the installers preset levels.
The second feature of party grouping can be used for multiple rooms that are architecturally open to each other. Here, the system can be set up such that when one room turns on to a source, the other rooms open to each other also turn on to that source. As sources are switched, these rooms will always track the same source. Because these rooms exist as independent zones on the Suite 16, they can still have their own acoustical levels and can turn off independently, but they will always share the same source.
The MC-5000 keypad has a feature set that permit the source buttons, instead of sending out input commands for a specific room, to send out input commands for a specific party group. If for example, three rooms: the entry foyer, living room, and dining room, all have a MC-5000 set to party group 2, when FM 2 is selected in the foyer, the other two rooms will also turn on to FM 2. If later, you change the living room to CD 1, the other areas will also switch to CD 1.
To set a room to track a particular party group, simply press the appropriate set button while on that room. To remove a room from that party group, press the clear button.
Page Grouping
Page grouping is set and cleared on a per room basis much like party grouping. Paging groups 1-6 are the serially controlled. Paging group 7 is triggered via audio sensing. Paging group 8 is triggered via low voltage.
Paging Volume Level
The volume level for pages is inde- pendent of the rooms volume level and is set by the slider control. When a page is initiated, the room ramps to that volume level, the tone controls are set to flat, and the filters are turned off. When the page is released, the room returns to the previous levels and input. If the room was off, it will return to the off state.
- 58 -
Global Room Control Page
The global room control tab features both party group and paging triggers as well as the input level trim controls.. The red button in the lower right hand corner is the update information request button.
Input Level Trim Adjustment
The trim level adjustment can lower the input of level of a source component. As such, the sources that play louder than the least loud source, can be balanced off to be as loud as the least loud source. As such, the least loud source becomes the reference input, where all other sources are lowered so that they are in balance to the least loud source. As such, when you change inputs, the volume levels between sources remains the same.
Party Group Testing
To test and/or activate a party group to a specific input, select the desired input from the pull down input window. Then press the desired party group button.
- 59 -
Paging Control
The paging control tab permits you to simulate paging triggers.
The first six triggers are only controlled serially. As such, a control code needs to be issued in order to activate triggers 1 through 6.
Paging group 7 is the audio sensing trigger. The sensitivity of this trigger is set on the front of the A-16 module by removing the plexiglass panel. Because a page will always cause the audio to be sensed, if you desire to defeat this trigger entirely (perhaps because you are only using serial triggers), this page has an option which permits you to disable paging group 7 entirely.
Paging group 8 is the low voltage trigger paging group, again hardwired directly to the back of the A-16 module.
When engaging any of the paging groups, you can opt to remove a room from being paged by selecting the page all except the desired room number pull down window.
You can also activate paging to a single room on this page. For direct paging, select the room number and then press the page button.
It is important to remember that when a page is activated, you must turn paging off before rooms return to their previous state. Once a page is initiated, it will remain on until it is turned off. In the case of triggers
7 & 8, the paging turns off when the trigger is removed.
In the case of paging group triggers 1-6 or room to room paging, you must turn all paging off.
If paging is on, there are two ways to turn paging off. If a room is being paged, selecting an alternate source input will turn the paging off for just that room. To reset paging for the entire system other than by issuing a serial control to do so, you will need to reset the system by turning the master power switch off on the front of the Suite 16.
- 60 -
Video Control Page
The video control tab permits control video direct selection, activation of the four video triggers, and also features the settings for video-follow-audio switching. To update this page, press the red button located in the lower left hand corner.
For direct video switching, select the room number from the pull down window and then press the desired video input. Even if the output is set to follow an active audio input, this switching will engage the newly selected input. You can also turn an active video input off to that room by press the off button.
There are four video triggers which can either be engaged serially, as on this page, or via low voltage. Setting these triggers will be discussed later on, but they are activated on this page.
The other options on this page involve setting video inputs to track audio selections. If an audio input has a video follower, you can set that input to track that audio selection. This function is also room specific, such that video follow audio tracking can be different in various rooms. The reason for this is simple. If a room has no video display of any type connected to the Suite 16, its room output can be used to drive another video device that is not room specific. For example, if room 3 physically has no TV, and room 4 has both a TV and a video capable touch screen, then the room 3 output can be used to drive video to the touch screen, while the room 4 output can be set to video-follow-audio. When using an open room output to drive a video display that is not intended to track any room’s audio selections, all video inputs to follow rooms must be in the clear
(or off) state. This will permit that room (output) to directly access video without interruption from other room audio activities. To cause a video input to follow its numeric audio counterpart, press the appropriate set buttons. To remove this feature, press the clear button. Remember to activate video-follow-audio tracking for each room. This is a room by room specific function, not a global function.
- 61 -
Video Trigger Setup Page
The video trigger setup tab incorporates the feature sets that determine what events occur when one of the four video triggers is activated. Here, the surveillance feature set of Suite 16 becomes obvious. To update this page, press the red box in the lower left hand corner of the window.
There are a total of four triggers which can be activated via serial command sets (as on the previous page) or low voltage triggers (connected directly to the V-16 module). You can choose to disable any of these four triggers in this page. This will be useful if the system is already wired for triggers, but you later wish to prevent a trigger from occurring. Instead of pulling out the rack to rewire the system, simply disable that trigger completely by turning it off.
To begin we will determine which rooms (or video outputs) are affected by a video trigger.
We specify outputs because some of the most useful effects of this feature set revolve around the ability to use open outputs to drive video capable touch-screens or closed-circuit TV monitors. Naturally, this feature also will override video playing on TV, much like the paging feature overrides audio playing in a room.
To set a room to follow a trigger or several triggers, pull down the room number from the assign trigger for room output section. To set a room (video output) to activate when a specific trigger is turned on, press the numeric set number for that trigger. To clear a trigger, press the clear button.
Now that we know which rooms (video outputs) track which triggers, we can determine what occurs when a trigger is activated. To start we will discuss the issue of video input trigger assignments. In this area of the page, select one of the four triggers using the pull down window. Next, determine which of the 16 video inputs are assigned to that trigger. For example, if video inputs 15 and 16 are open on the V-16, they could have closed circuit TV cameras connected to them. If in this example, inputs 15 and 16 are the two cameras cover-
- 62 -
ing the front door, and you want to assign these cameras to trigger number 1, select trigger number 1 from the pull down window and then set input 15 and 16 by pressing the appropriate set buttons. To clear these inputs from these triggers, press the clear buttons.
To determine what triggers do when they are activated, Suite 16 features a cycle count and dwell time setting. These two settings are global in that they will affect all four triggers. If you change the cycle count or dwell time for one trigger, you will alter the features for the other triggers. As such, you will want to give some thought into how you set cycle count and dwell time when using more than one trigger.
Dwell time refers to the length the input is held and is adjustable from a 1 second to 60 second time frame. Cycle count refers to the number of cycles that are repeated before the trigger is released. Cycle count goes from one cycle to 99 cycles. As such, the shortest time interval can be 1 second (dwell time = 1 second & cycle count = 1) all the way up to 99 minutes (dwell time = 60 seconds & cycle count = 99). In the example previously used, with two cameras covering the front door, when the front doorbell is pressed, trigger 1 engages. If the dwell time is set to 3 seconds and the cycle count is set to 4, then the first camera is displayed for three seconds, then the second camera for three seconds. This sequence will repeat three more times and then the trigger will turn off (24 seconds total time - 3x4 + 3x4).
If trigger number two has just one camera by the front gate which is activated with an electronic eye, then when trigger number two is engaged, the gate camera will be held for a period of 12 seconds (3 second dwell time x 4 cycles). Even though the Suite 16 is cycling, the image for a single input on a trigger is held steady without flutter.
To set the cycle count and dwell time, use the sliders bearing in mind that these features are global and will affect all four triggers.
- 63 -
Suite 16 Serial Protocol V1.4 Explanation
PURPOSE:
This document explains the serial data code structure and operation of the Suite 16 Multi-
Room Preamplifier. This document is preliminary and is for Suite 16 Audio card with version
1.4 software. All content subject to change.
DISCUSSION:
The Suite 16 Multi-Room Preamplifier is serial controlled at 19200 baud or 1200 baud. The
10 character command structure is as follows:
START CHARACTER ACTION
Example ‘ S or G
FUNCTION ROOM#/GLOBAL <CR>
AD01 R01 <CR>
The above example demonstrates how you would set room 1 to analog input 1. The start character must always be a ‘ called an accent grave, located on the key next to the 1 key on a standard QWERTY keyboard. All letters used in a 10 character string must be upper case.
The end of the string must always end in a carriage return or “ENTER” key. The second character is “S” for set when performing a function. When updates about system status are requested this character will be a “G” for get. The third through sixth characters are the function code. Referring to the excel sheet you can look up the various functions that the preamplifier can perform. In some cases, like the volume direct command, some of the characters are a value entered into the system. The seventh through ninth characters are for telling the system that the command is for a specific room or a global function. Like the function code, some of the characters can be a variable for certain functions.
After there is a power failure and power is restored, the system will return to the last active settings for every room including whether the room was on or off, tone controls, volume, input trim, balance and input selected. The exception being if any page mode had been activated by serial command it will be cancelled. If a page mode is being activated manually or by auto audio level detection then the page will be active on power up.
The feedback response is an 11 character string
START
CHAR
Acknowledge PLACE
HOLDER
FUNCTION
Example ‘ A X AD01
The “A” is for acknowledge and is in every feedback response
ROOM or
GLOBAL
R01 <cr>
The “X” is a placeholder but is used only for feedback in the volume, tone and balance presets
- 64 -
DESCRIPTION OF COMMANDS:
ALL OFF
Powers down all rooms, amplifiers and source equipment; a global shutdown
EXAMPLE ‘SALOFG00<cr> shut system down
Feedback ‘AXALOFG00<cr>
Feedback Request ‘GALOFG00<cr>
Feedback ‘AXALOFG00<cr> or
‘ASYSONG00
INPUT UP
Each input up command will advance to the next numbered audio input for a given room.
When the input is 16 and the input up command is requested the system will roll over to input
1 and continue to advance to the next highest input. If the room was powered down it will turn on with the previous input before it was powered down.
EXAMPLE ‘SINUPR01<cr> step input up by one
Feedback ‘AXAD02R01<CR> feedback reflects current input for selected room
Feedback Request ‘GINUPR01<cr>
Feedback
Or
Or
‘AXRMOFR01<cr>
‘AXAD##R01<cr>
‘AXALOFG00<cr> room 1 is off current input selected for room 1 system is off
INPUT DOWN
Each input down command will decrement to the next numbered audio input for a given room.
When the input is 1 and the input down command is requested the system will roll over to input 16 and continue to decrement to the next lowest input. If the room was powered down it will turn on with the previous input before it was powered down.
EXAMPLE
Feedback
‘SINDNR01<cr>
‘AXAD02R01<CR> feedback reflects current input for selected room
Feedback Request ‘GINDNR01<cr>
Feedback
Or
Or
‘AXRMOFR01<cr>
‘AXAD##R01<cr>
‘AXALOFG00<cr> room 1 is off current input selected for room 1 system is off
- 65 -
INPUT 1-INPUT 16
Directly selects one of the 16 discreet audio inputs for a given room. If the room was off the room will now be turned on and its associated amplifier and source equipment will be activated.
EXAMPLE ‘SAD01R01<cr> select audio input 1 for room 1
Feedback ‘AXAD01R01<cr>
Feedback Request ‘GAD##R01<cr>
Feedback
Or
Or
‘AXRMOFR01<cr>
‘AXAD##R01<cr>
‘AXALOFG00<cr> room 1 is off current input selected for room 1 system is off
MUTE TOGGLE
Each mute toggle command will toggle that room between mute and unmute. No function when room is off. Feedback request allowed when room is off.
toggle mute in room 1 EXAMPLE ‘SMTOGR01<cr>
Feedback Request ‘GMTOGR01<cr>
Feedback
Or
‘AXMTONR01<cr>
‘AXMTOFR01<cr> room 1 mute is on room 1 mute is off
MUTE ON
Mutes the audio signal for the selected room. No function when room is off. Feedback request allowed when room is off.
EXAMPLE ‘SMTONR01<cr> mute room 1
Feedback ‘AXMTONR01<cr>
Feedback request ‘GMTONR01<cr>
Feedback
Or
‘AXMTONR01<cr>
‘AXMTOFR01<cr> room 1 mute is on room 1 mute is on room 1 mute is off
MUTE OFF
Unmutes the audio signal for the selected room. No function when room is off. Feedback request allowed when room is off.
EXAMPLE ‘SMTOFR01<cr> unmute room 1 room 1 mute is on Feedback ‘AXMTOFR01<cr>
Feedback request ‘GMTOFR01<cr>
Feedback ‘AXMTONR01<cr>
Or ‘AXMTOFR01<cr> room 1 mute is on room 1 mute is off
- 66 -
ROOM OFF
Shuts down the selected room. If it is the only room on in the system the response will be all off.
EXAMPLE ‘SRMOFR01<cr>
Feedback ‘AXRMOFR01<cr> or
‘AXALOFG00
Feedback Request ‘GRMOFR01<cr>
Feedback
Or
Or
EXAMPLE
‘AXRMOFR01<cr>
‘AXAD##R01<cr>
‘AXALOFG00<cr>
‘SVLUPR01<cr> turn off room 1 room 1 is off all off when last room turned off room 1 is off current input selected for room 1 system is off
VOLUME UP
Advances the volume by 1 up to a maximum of 40 for a given room. If the volume has reached 40 any additional commands will result in a volume level of 40. No function when room is off. Feedback request allowed when room is off.
increment volume up by 1 in room 1 current volume set in room 1 Feedback ‘AXV###R01<cr>
Feedback Request ‘GVLUPR01<cr>
Feedback ‘AXV###R01<cr> current volume set in room 1
VOLUME DOWN
Decrements the volume by 1 to a minimum of 0 for a given room. If the volume has reached
0 and additional commands will result in a volume level of 0. No function when room is off.
Feedback request allowed when room is off.
EXAMPLE ‘SVLDNR01<cr>
Feedback ‘AXV###R01<cr>
Feedback Request ‘GVLDNR01<cr>
Feedback ‘AXV###R01<cr> decrement volume by 1 in room 1 current volume set in room 1 current volume set in room 1
VOLUME DIRECT
Allows you to go directly to a volume level for a given room. The function command is in the form of V### where ###is a number from 000 to 040. No function when room is off. Feedback request allowed when room is off.
EXAMPLE ‘SV040R01<cr> set maximum volume in room 1
Feedback ‘AXV040R01<cr>
Feedback Request ‘GV###R01<cr>
Feedback ‘AXV###R01 volume is set to maximum in room 1 current volume value for room 1
- 67 -
BASS UP
Advances bass by 2dB for a given room. The range of Bass is +12dB to -12dB incremented by 2dB. When set to 0dB bass is flat. No function when room is off. Feedback request allowed when room is off.
EXAMPLE ‘SBSUPR01<cr> increment bass up by one step in room 1
Feedback ‘AXB###R01<cr> current bass value for room 1
(-12,-10,-08,-06,-04,-02,000,+02,+04,+06,+08,+10,+12)
Request Feedback ‘GBSUPR01<cr>
Feedback ‘AXB###R01<cr> current bass value for room 1
BASS DOWN
Decrements bass by 2dB for a given room. No function when room is off. Feedback request allowed when room is off.
EXAMPLE
Feedback
‘SBSDNR01<cr>
‘AXB###R01<cr>
EXAMPLE ‘SB+12R01<cr>
Feedback ‘AXB+12R01<cr>
Request Feedback ‘GB###R01<cr>
Feedback ‘AXB###R01<cr> decrement bass by one step in room 1 current bass value for room 1
Request Feedback ‘GBSDNR01<cr>
Feedback ‘AXB###R01<cr> current bass value for room 1
BASS DIRECT
Allows you to go directly to a bass value for a given room. No function when room is off.
Feedback request allowed when room is off.
The command is in the form of B### where ### can be any of 13 values and is signed. The possible combinations are:
B-12,B-10,B-08 B-06,B-04,B-02,B000, B+02,B+04,B+06,B+08,B+10,B+12 set maximum bass in room 1 current bass value for room 1 current bass value for room 1
TREBLE UP
Advances treble by 2dB for a given room. No function when room is off. Feedback request allowed when room is off.
The range of treble is +12dB to -12dB. When set to 0dB treble is flat.
EXAMPLE ‘STRUPR01<cr> increment treble up one step
Feedback ‘AXT###R01<cr> current treble value for room 1
(-12,-10,-08,-06,-04,-02,000,+02,+04,+06,+08,+10,+12)
Request Feedback ‘GTRUPR01<cr>
Feedback ‘AXT###R01<cr> current treble value for room 1
- 68 -
TREBLE DOWN
Decrements treble by 2dB for a given room. No function when room is off. Feedback request allowed when room is off.
EXAMPLE
Feedback
‘STRDNR01<cr>
‘AXT###R01<cr> decrement treble by 1 step in room 1 current treble value for room 1
Request Feedback ‘GTRDNR01<cr>
Feedback ‘AXT###R01<cr> current treble value for room 1
TREBLE DIRECT
Allows you to go directly to a treble value for a given room. No function when room is off.
Feedback request allowed when room is off.
The command is in the form of T### where ### can be any of 13 values and is signed. The possible combinations are:
T-12,T-10,T-08 T-06,T-04,T-02,T000, T+02,T+04,T+06,T+08,T+10,T+12
EXAMPLE
Feedback
‘ST+12R01<cr>
‘AXT+12R01<cr> set maximum treble in room 1 current treble value for room 1
Request Feedback ‘GT###R01<cr>
Feedback ‘AXT###R01<cr> current treble value for room 1
TONE STORE 1-4
Allows you to store 4 preset combinations of bass, treble, loudness contour and stereo enhance for a given room. This command will store the current active tone values. No function when room is off. Feedback request allowed when room is off.
EXAMPLE ‘STNS1R01<cr> store current room 1 tone settings in tone recall 1
Feedback ‘AB1###R01<cr>
‘AT1###R01<cr> tone preset 1 bass value tone preset 1 treble value
‘ALD1OFR01<cr> or ‘ALD1ONR01<cr> tone preset 1 loudness off or on
‘AST1OFR01<cr> or ‘AST1ONR01<cr> tone preset for stereo enhance off/on
Feedback Request ‘GTNS1R01<cr>
Feedback ‘AB1###R01<cr>
‘AT1###R01<cr>
‘ALD1OFR01<cr> or ‘ALD1ONR01<cr>
‘AST1OFR01<cr> or ‘AST1ONR01<cr> tone preset 1 bass value tone preset 1 treble value tone preset 1 loudness off or on tone preset for stereo enhance off/on
- 69 -
TONE RECALL 1-4
Allows you to recall 4 pre-stored combinations of bass, treble, loudness contour and stereo enhance. No function when room is off. Feedback request allowed when room is off.
‘STNR1R01<cr> EXAMPLE
Feedback ‘AXB###R01<cr>
‘AXT###R01<cr>
‘AXLDONR01<cr> or
‘AXLDOFR01<cr>
‘AXSEONR01<cr> or
‘AXSEOFR01 recall tone 1 settings for room 1 current bass value for room 1 current treble value for room 1 current loudness for room 1 current stereo enhance for room 1
Feedback Request ‘GTNR1R01<cr>
Feedback ‘AB1###R01<cr>
‘AT1###R01<cr>
‘ALD1OFR01<cr> or ‘ALD1ONR01<cr>
‘AST1OFR01<cr> or ‘AST1ONR01<cr> tone preset 1 bass value tone preset 1 treble value tone preset 1 loudness off or on tone preset for stereo enhance off/on
VOLUME STORE 1-4
Allows you store 4 preset volume levels for a given room. The current volume level active when command is initiated will be stored. No function when room is off. Feedback request allowed when room is off.
EXAMPLE
Feedback
‘SVLS1R01<cr>
‘AV1###R01<cr>
Feedback Request ‘GVLS1R01<cr>
Feedback ‘AV1###R01<cr> store current room 1 volume in volume recall 1 volume preset 1 stored volume value volume preset 1 stored volume value
VOLUME RECALL 1-4
Allows you to recall 4 pre-stored volume levels for a given room. No function when room is off.
Feedback request allowed when room is off.
EXAMPLE ‘SVLR1R01<cr> make volume in volume recall 1 active for room 1 current volume value for room 1 Feedback ‘AXV###R01<cr>
Feedback Request ‘GVLR1R01<cr>
Feedback ‘AV1###R01<cr> volume stored in volume preset 1
LOUDNESS CONTOUR ON
Turns on loudness contour mode for a given room. No function when room is off. Feedback request allowed when room is off.
EXAMPLE ‘SLDONR01<cr>
Feedback ‘AXLDONR01<cr>
Feedback Request ‘GLDONR01<cr> turn on loudness contour for room 1
Feedback ‘AXLDONR01<cr> or ‘AXLDOFR01<cr> Loudness contour on or off in room 1
- 70 -
LOUDNESS CONTOUR OFF
Turns off loudness contour mode for a given room. No function when room is off. Feedback request allowed when room is off.
EXAMPLE ‘SLDOFR01<cr>
Feedback ‘AXLDOFR01<cr>
Feedback Request ‘GLDOFR01<cr> turn off loudness contour for room 1
Feedback ‘AXLDONR01<cr> or ‘AXLDOFR01<cr> Loudness contour on or off in room 1
STEREO ENHANCE ON
Turns on stereo enhance mode for a given room. No function when room is off. Feedback request allowed when room is off.
EXAMPLE
Feedback
‘SSEONR01<cr>
‘AXSEONR01<cr> turn on stereo enhance mode for room 1
Feedback Request ‘GSEONR01<cr>
Feedback ‘AXSEONR01<cr> or ‘AXSEOFR01<cr> Loudness contour on or off in room 1
STEREO ENHANCE OFF
Turns off stereo enhance mode for a given room. No function when room is off. Feedback request allowed when room is off.
EXAMPLE ‘SSEOFR01<cr>
Feedback ‘AXSEOFR01<cr>
Feedback Request ‘GSEOFR01<cr> turn off stereo enhance mode for room 1
Feedback ‘AXSEONR01<cr> or ‘AXSEOFR01<cr> Loudness contour on or off in room 1
STEREO
Places a given room in Stereo mode. No function when room is off. Feedback request allowed when room is off.
place room 1 in stereo mode EXAMPLE
Feedback
‘SSTROR01<cr>
‘AXSTROR01<cr>
Feedback Request ‘GSTROR01<cr>
Feedback ‘AXSTROR01<cr>
‘AXMINLR01<cr>
‘AXMINRR01<cr> or room 1 in stereo mode
orroom 1 in mono input left mode room 1 in mono input right mode
MONO INPUT LEFT
Selects left source input to be routed to left and right speakers for a given room
No function when room is off. Feedback request allowed when room is off.
left input to left and right speakers in room 1 EXAMPLE
Feedback
‘SMINLR01<cr>
Feedback ‘AXMINLR01<cr>
Feedback Request ‘GMINLR01<cr>
‘AXSTROR01<cr>
‘AXMINLR01<cr>
‘AXMINRR01<cr> or room 1 in stereo mode or room 1 in mono input left mode room 1 in mono input right mode
- 71 -
MONO INPUT RIGHT
Selects right source input to be routed to left and right speakers for a given room
No function when room is off. Feedback request allowed when room is off.
EXAMPLE ‘SMINRR01<cr> right input to left and right speakers in room 1
Feedback ‘AXMINRR01<cr>
Feedback Request ‘GMINRR01<cr>
Feedback ‘AXSTROR01<cr>
‘AXMINLR01<cr>
‘AXMINRR01<cr> or room 1 in stereo mode or room 1 in mono input left mode room 1 in mono input right mode
BALANCE LEFT
Increment by 1 balance to the left for a given room. No function when room is off. Feedback request allowed when room is off.
EXAMPLE
Feedback
‘SBALLR01<cr>
‘AXB###R01<cr>
Feedback Request ‘GBALLR01<cr> increment by 1 balance to the left in room 1 current balance value for room 1
(L40/R40/LEQ)
Feedback ‘AXB###R01<cr> current balance value in room 1
BALANCE RIGHT
Increment by 1 balance to the right in a given room
No function when room is off. Feedback request allowed when room is off.
EXAMPLE
Feedback
‘SBALRR01<cr>
‘AXB###R01<cr> increment by 1 balance to the right in room 1 current balance value for room 1
Feedback Request ‘GBALRR01<cr>
Feedback ‘AXB###R01<cr> current balance value in room 1
BALANCE EQUAL
Sets balance equal for a given room
No function when room is off. Feedback request allowed when room is off.
EXAMPLE ‘SBLEQR01<cr> set balance equal in room 1
Feedback ‘AXBLEQR01<cr>
Feedback Request ‘GBLEQR01<cr>
Feedback ‘AXB###R01 current balance value for room 1
- 72 -
BALANCE STORE 1-2
Allows you to store 2 balance settings for a given room. The current active balance setting is stored. No function when room is off. Feedback request allowed when room is off.
EXAMPLE ‘SBLS1R01<cr> store current room 1 balance setting in balance recall 1
Feedback ‘A1B###R01<cr>
Feedback request ‘GBLS1R01<cr>
‘GBLS2R01<cr> request balance store 1 for room 1 or request balance store 2 for room 1
Feedback ‘A1B###R01<cr> or
`A2B###R01<cr> balance stored in balance preset 1 for room 1 balance stored in balance preset 2 for room 1
BALANCE RECALL 1-2
Allows you to recall 2 pre-stored balance setting for a given room. No function when room is off. Feedback request allowed when room is off.
EXAMPLE
Feedback
‘SBLR1R01<cr>
‘AXB###R01<cr>
Feedback request ‘GBLR1R01<cr>
‘GBLR2R01<cr>
Feedback ‘A1B###R01<cr> or
‘A2B###R01<cr> make balance recall 1 active for room 1 current balance value for room 1 request balance store 1 for room 1 or request balance store 2 for room 1 balance stored in balance preset 1 for room 1 balance stored in balance preset 2 for room 1
INPUT LEVEL TRIM 1-16
This is a global command that allows you to trim louder input sources so they may be at relatively even volumes with other sources. When properly set any source can be selected and the volume for that room should not have to be re-adjusted. Every room in the system will attenuate the source by the value set, if any, with this command. The command structure is the function code selects which input trim to adjust followed by G for global and the 2 digit trim value. A trim level set to 00 will cause no attenuation for that input. Each value of trim is about
1.5dB of attenuation.
EXAMPLE ‘SIT01G01<cr>
‘SIT16G02<cr>
‘SIT02G00<cr>
Set input trim 1 for 1.5dB attenuation
Set input trim 16 for 3dB attenuation
Set input trim 2 for no attenuation
Feedback
Feedback request
Feedback
‘AXIT##G##<cr>
‘GIT##G00<cr>
‘AXIT##G##<cr>
- 73 -
PARTY SET 1-4
Allows any given room to become a “member” of party 1-4
EXAMPLE ‘SPTS1R01<cr> set room 1 to be a member of party 1
Feedback ‘AXPTS1R01<cr>
Feedback Request ‘GPTS1R01<cr>
Feedback ‘AXPTS1R01<cr>
‘AXPTC1R01 or room 1 is in party 1 room 1 is not in party 1
PARTY CLEAR 1-4
Clears a given room from party 1-4
EXAMPLE ‘SPTC1R01<cr> clear room 1 from party 1
Feedback ‘AXPTC1R01<cr>
Feedback Request ‘GPTC1R01<cr>
Feedback ‘AXPTS1R01<cr>
‘AXPTC1R01 or room 1 is in party 1 room 1 is not in party 1
PARTY 1-4
The party command is a global function of 4 pre-selected groups of rooms. The room members of each party are turned on and set to the same source input in the command string. The
2 characters after the G specify the input to set the party to in the range 01 to 16.
EXAMPLE ‘SPTY1G01<cr> set all members of party 1 to input 1
Feedbackcurrent room inputs for each room in party ‘AXAD##R##<cr>
PAGING OVERVIEW
The paging function of the preamplifier actually has 9 ways to accomplish paging. There are
8 paging groups any room can become a “member” of. Each room also has a serial command to pre-set a paging level for that room. When a room is paged all balance and tone controls are nulled and the preset page volume is set. After completion of page, control resume their setting previous to the page. If the room had been turned off it will turn on for the page and then turn off again when the page is completed. The first 6 groups use serial controlled paging. Group 7 is the auto paging mode and is hardware controlled. This is controlled by an audio level detector. When an audio signal applied to the auto page input exceeds a predetermined level, all members that are part of group 7 are paged. In the event of interference or noise inadvertently activating auto page, there is a serial command which can activate or deactivate the auto page mode. Group 8 is another hardware controlled paging mode. This is a simple dry contact input that will page members of group 8. The ninth method of paging is the room to room page. With this command any room can be discretely paged. Only one page can occur at one time. The method of page activation must also be used to cancel the page. For example, a manual page by contact closure must be cancelled by opening the contact. An auto page by audio level activation must be cancelled by the level being below the trigger threshold. Any serial controlled page must be cancelled by a serial command. For serial command page groups 1-6, if the room initiating the page is part of the group, it will be omitted so no audio feedback occurs. Functions are as follows:
- 74 -
PAGE VOLUME PRESET
Allows a predetermined paging level to be set for a given room. The command structure is
PV## where ## is the preset page volume 00 to 40 set page volume to maximum for room 1 EXAMPLE ‘SPV40R01<cr>
Feedback ‘AXPV40R01<cr>
Feedback Request ‘GPV##R01<cr>
Feedback ‘AXPV##R01<cr> current page volume preset value
PAGE DIRECT (direct page to only one room)
Allows direct paging to a specific room. The room is specified by the 2 characters after the G in the range of 01 to 96. Must be cancelled by the page off command
EXAMPLE ‘ SPDONG01<cr> page room 1 only
Feedback ‘AXPDONG01<cr>
Feedback Request ‘GPDONG00<cr>
Feedback ‘AXP#O#G00<cr> current paging mode
PAGE OFF
This is a global command used to turn off any serial page mode.
EXAMPLE ‘SPGOFG00<cr>
Feedback ‘AXPGOFG00<cr>
Feedback Request ‘GPGOFG00<cr>
Feedback ‘AXP#O#G00<cr> current paging mode
PAGE ENABLE GROUP 1-8
Allows any room to become a “member” of any paging group 1-8
EXAMPLE ‘SPGS1R01<cr>
Feedback ‘AXPGS1R01<cr>
Feedback Request ‘GPGS#R##<cr>
Feedback ‘AXPGS#R##<cr>
‘AXPGC#R##<cr>
PAGE DISABLE GROUP 1-8
Clears any room from any paging group 1-8 make room 1 a member of paging group 1 page for # group set for room ## or page for # group not set for room ##
EXAMPLE‘SPGC1R01<cr>clear room 1 from paging group 1
Feedback ‘AXPGC1R01<cr>
Feedback Request ‘GPGC#R##<cr>
Feedback ‘AXPGS#R##<cr>
‘AXPGC#R##<cr> page for # group set for room ## or page for # group not set for room ##
- 75 -
PAGE GROUP 1-6
Serial controlled paging of any group 1-6. Must be followed by the page off command when page completed. For audio feedback prevention, include the room number after the G to temporarily exclude it from the group.
EXAMPLE
Feedback
‘SP#ONG00<cr>
‘SP#ONG30<cr>
‘AXP#ONG00>cr
or page a group where # = 1 to 6 page but exclude room 30
Feedback Request ‘GP#ONG00<cr>
Feedback ‘AXP#ONG00<cr> or
‘AXPGOFG00<cr> current active page mode all page modes off
AUTO PAGE ON
Turns on the audio level detector for group 7. This is a global command.
EXAMPLE
Feedback
‘SPAONG00<cr>
‘AXPAONG00<cr> make auto paging active
Feedback Request ‘GPAONG00<cr>
Feedback ‘AXPAONG00<cr> or
‘AXPAOFG00<cr>
AUTO PAGE OFF
Turns off audio level detector for group 7 and cancels any page mode. This is a global command make auto paging inactive EXAMPLE ‘SPAOFG00<cr>
Feedback ‘AXPAOFG00<cr> or
‘AXPGOFG00<cr>
F eedback Request ‘GPAOFG00<cr>
Feedback ‘AXPAONG00<cr> or
AXPAOFG00<cr>
AUTO PAGE (aka group 7)
Audio level detection activated page. When audio exceeds a predetermined trigger threshold page will activate for all rooms that are members of group 7. Paging is complete when audio is below the trigger threshold. This is a hardware controlled feature. It must be enabled using the auto page on command.
Feedbackwhen activated
When deactivated
‘AXP7ONG00<cr>
‘AXPGOFG00<cr>
- 76 -
MANUAL PAGE (aka group 8)
Contact closure controlled page. All members of group 8 are paged. When contacts are released paging is complete.
Feedbackwhen activated
When deactivated
‘AXP8ONG00<cr>
‘AXPGOFG00<cr>
MAXIMUM ALLOWABLE VOLUME
Allows you to set a maximum allowable volume level per room. The command is in the form of MV## where ## is the allowable level 10 to 40.
EXAMPLE ‘SMV40R01<cr> set maximum volume to 40 for room 1
Feedback
Feedback Request
Feedback
‘AXMV40R01<cr>
‘GMV##R##
‘AXMV##R##
ROOM TURN ON WITH LAST USED VOLUME, TONE, BALANCE
Room will turn on and use previous volume, bass, treble, stereo enhance, loudness contour and balance settings.
EXAMPLE ‘SVPOFR01<cr> use previous settings for tone, balance and volume in room 1
Feedback ‘AXVPOFR01<cr>
Feedback Request ‘GVPOFR01<cr>
Feedback ‘AXVPONR01<cr> or
‘AXVPOFR01<cr>
ROOM TURN ON WITH VOLUME, TONE AND BALANCE IN PRESET 1
Room will turn on using volume, bass, treble, stereo enhance, loudness contour and balance stored in volume preset 1, tone preset 1 and balance preset 1.
EXAMPLE ‘SVPONR01<cr> use preset 1 for tone, balance and volume
Feedback ‘AXVPONR01<cr>
Feedback Request ‘GVPONR01<cr>
Feedback ‘AXVPONR01<cr> or
‘AXVPOFR01<cr>
VERSION REQUEST
This is a global command which will indicate the software version of each card. All audio cards in the system will respond sequentially.
EXAMPLE Feedback Request
Feedback
‘GVERSG00<cr>
‘A0VERS1.4<cr>
‘A1VERS1.4<cr> card 0 has version 1.4 software card 1 has version 1.4 software
- 77 -
RESET TO FACTORY DEFAULT VALUES
Resets all parameters to factory default values. All volumes and volume presets are set to half, bass and treble set flat, balance and balance presets set to equal, stereo enhance off, loudness contour off, stereo mode on, mute off, all rooms off, all input trims 0, all page groups cleared, all parties cleared, all tone presets, bass and treble set flat, stereo enhance off, loudness contour off, auto page off, maximum volume per room set to 40, page volume per room set to 30, auto page mode off, power up on last room parameters.
reset unit to factory default values EXAMPLE
Feedback
‘SFDEFG00<cr>
‘AXFDEFG00<cr>
UPDATE ALL ROOM PARAMETERS
This is a global command which will feedback all parameters of every room in the system and also global parameters . This command can be requested only.
‘GALRMG00<cr> EXAMPLE
Feedback ‘AXPAO#G00<CR>
‘AXIT01G##<CR>
‘AXIT02G##<CR>
‘AXIT03G##<CR>
‘AXIT04G##<CR>
‘AXIT05G##<CR>
‘AXIT06G##<CR>
‘AXIT07G##<CR>
‘AXIT08G##<CR>
‘AXIT09G##<CR>
‘AXIT10G##<CR>
‘AXIT11G##<CR>
‘AXIT12G##<CR>
‘AXIT13G##<CR>
‘AXIT14G##<CR>
‘AXIT15G##<CR>
‘AXIT16G##<CR> auto page on/off input trim 1 input trim 2 input trim 3 input trim 4 input trim 5 input trim 6 input trim 7 input trim 8 input trim 9 input trim 10 input trim 11 input trim 12 input trim 13 input trim 14 input trim 15 input trim 16 and then same feedback as update room for each room
- 78 -
UPDATE ALL ROOM CONTROLS
This is an abridged request that only replies with certain room parameters for all rooms as follows:
EXAMPLE ‘GALRCG00<cr>
Feedback *this feedback sequence is repeated for each room
‘AXV###R##<cr>
‘AXB###R##<cr>
‘AXT###R##<cr>
‘AXB###R##<cr>
‘AX####R##<cr>
‘AXVPO#R##<cr>
‘AXMV##R##<cr>
‘AXMTO#R##<cr>
‘AX ####R##<cr>
‘AXLDO#R##<cr>
‘AXSEO#R##<cr> volume bass treble balance current input or room off or all off volume preset on/off max volume mute on or off stereo or mono in L or mono in R loudness contour on/off stereo enhance on/off
UPDATE A SINGLE ROOM CONTROL
This is like the Update All Room Controls command but replies with information for a single room.
‘GRCONR01<cr> EXAMPLE
Feedback ‘AXV###R01<cr>
‘AXB###R01<cr>
‘AXT###R01<cr>
‘AXB###R01<cr>
‘AX####R01<cr>
‘AXVPO#R01<cr>
‘AXMV##R01<cr>
‘AXMTO#R01<cr>
‘AX ####R01<cr>
‘AXLDO#R01<cr>
‘AXSEO#R01<cr> volume bass treble balance current input or room off or all off volume preset on/off max volume mute on or off stereo or mono in L or mono in R loudness contour on/off stereo enhance on/off
UPDATE ROOM
All parameters for any single room
‘GROOMR##<cr> EXAMPLE
Feedback ‘AXV###R01<cr>
‘AXB###R01<cr>
‘AXT###R01<cr>
‘AXB###R01<cr> volume bass treble balance
- 79 -
‘AX####R01<cr>
‘AXVPO#R01<cr>
‘AXMV##R01<cr>
‘AXMTO#R01<cr>
‘AX ####R01<cr>
‘AXLDO#R01<cr>
‘AXSEO#R01<cr>
‘AV1###R01<cr>
‘AV2###R01<cr>
‘AV3###R01<cr>
‘AV4###R01<cr>
‘A1B###R01<cr>
‘A2B###R01<cr>
‘AB1###R01<cr>
‘AT1###R01<cr>
‘ALD1OFR01<cr> or ‘ALD2ONR01<cr>
‘ASE1OFR01<cr> or ‘AST2ONR01<cr>
‘AB2###R01<cr>
‘AT2###R01<cr>
‘ALD2OFR01<cr> or ‘ALD2ONR01<cr>
‘ASE2OFR01<cr> or ‘AST2ONR01<cr>
‘AB3###R01<cr>
‘AT3###R01<cr>
‘ALD3OFR01<cr> or ‘ALD2ONR01<cr>
‘ASE3OFR01<cr> or ‘AST2ONR01<cr>
‘AB4###R01<cr>
‘AT4###R01<cr>
‘ALD4OFR01<cr> or ‘ALD2ONR01<cr>
‘ASE4OFR01<cr> or ‘AST2ONR01<cr>
‘AXPT#1R01<cr>
‘AXPT#2R01<cr>
‘AXPT#3R01<cr>
‘AXPT#4R01<cr>
‘AXPV##R01<cr>
‘AXPG#1R01<cr>
‘AXPG#2R01<cr>
‘AXPG#3R01<cr>
‘AXPG#4R01<cr>
‘AXPG#5R01<cr>
‘AXPG#6R01<cr>
‘AXPG#7R01<cr>
‘AXPG#8R01<cr> current input or room off or all off volume preset on/off max volume mute on or off stereo or mono in L or mono in R loudness contour on/off stereo enhance on/off volume preset 1 volume preset 2 volume preset 3 volume preset 4 balance preset 1 balance preset 2 tone preset 1 bass value tone preset 1 treble value tone preset 1 loudness off or on tone preset 1 for stereo enhance off/on tone preset 2 bass value tone preset 2 treble value tone preset 2 loudness off or on tone preset 2 for stereo enhance off/on tone preset 3 bass value tone preset 3 treble value tone preset 3 loudness off or on tone preset 3 for stereo enhance off/on tone preset 4 bass value tone preset 4 treble value tone preset 4 loudness off or on tone preset 4 for stereo enhance off/on party enable 1 party enable 2 party enable 3 party enable 4 page volume preset page enable 1 page enable 2 page enable 3 page enable 4 page enable 5 page enable 6 page enable 7 page enable 8
- 80 -
CHARACTER ECHO COMMAND
The character echo command is useful when data is to be sent from one remote control device to another. Normally a remote control device can only send data to the Suite 16 unit to request a function. For specialized functions such as label copying, the character echo command can be utilized. The command begins by using a ‘ just like all other commands and is then followed by E for echo. You then tell the system how many characters you want to echo in the value of 1 to 255 not including the first 3 characters (‘E and #bytes to send . This is a binary value, NOT an ASCII value.
EXAMPLE
SEND to suite16‘E 21 send this to a remote
REPLY from suite16send this to a remote
In the above example “send this to a remote” is 21 characters including the spaces. If you send less characters than specified, the system will time out after about 1/2 second and take commands normally for any function. If you send more characters than specified, the echo will complete after the number of characters specified. Any additional characters will be invalid.
Suite 16 Video Card V1.1 or V1.2 Protocal Explanation
1.
FEEDBACK DISABLE ****this is not yet implemented or must have traces cut to accomplish***
For Multiple card ie for S-video set to the same room group, There should be a hardware pin to disable the serial TX as more than one card with the same address could be confusing to program serially.
2.
DIRECT VIDEO SELECTION
Code examples
‘SVD01R01<cr>
‘SVD16R80<cr>
‘SVD00R50<cr> has feedback
This function is always active. At anytime any output may be assigned a video input or turned off.
Feedback will be generated from this command.
select video input 1 for output into room 1 select video input 16 for output into room 80 turn video off in room 50
- 81 -
3.
VIDEO FOLLOWING AUDIO/INDEPENDANT VIDEO has feedback
This function is assignable for every input in any given room. That way if only a few of the inputs are video components only those set will follow audio selections. If following is set for any input in a room, the remaining inputs not set to follow will turn off the room video output when selected. If following is not set for any input in a room, the video functions independently without any audio interaction at all.
Code examples
‘SFS01R01<cr>
‘SFC01R01<cr> video input 1 will follow audio in room 1 video input 1 will not change with audio in room 1
4.
PARTY COMMAND
Works just like audio party command but with no feedback using same set up commands as the P-16 audio card. Keep in mind video following settings will affect the party commands.
5.
HARDWARE TRIGGER VIDEO INPUT ASSIGN has feedback
This serial command assigns which video inputs are used in conjunction with each of the four hardware triggers and fifth serial only trigger. Up to 16 inputs can be assigned to a trigger.
Code examples
‘SHI1SG01<cr>
‘SHI4SG16<cr>
‘SHI2CG15<cr> assign to hardware trigger 1 video input 1 assign to hardware trigger 4 video input 16 disable from hardware trigger 2 video input 15
6.
TRIGGER OUTPUT ASSIGN has feedback
This serial command assigns room outputs to one of the five trigger groups.
Code examples
‘SHO1SR01<cr>
‘SHO1CR01<cr>
‘SHO5SR16<cr>
‘SHO3CR08<cr>
Set room 1 to trigger 1
Clear room 1 from trigger 1
Set room 16 to trigger 5
Clear room 8 from trigger 3
7.
SOFTWARE CONTROL OF HARDWARE TRIGGERS
This is a global serial command to activate triggers by command string. Result is same as if activated by hardware trigger. Trigger 5 is serial controlled only.
Code examples
‘STRG1G00<cr>
‘STRG2G00<cr>
‘STRG3G00<cr>
‘STRG4G00<cr>
‘STRG5G00<cr> activate trigger 1 activate trigger 2 activate trigger 3 activate trigger 4 activate trigger 5
- 82 -
8.
VIDEO TRIGGER DWELL TIME has feedback
This serial command globally sets the dwell time. Dwell time is the interval that a video input selection remains on until it switches to the next in sequence. Range is 1-60 seconds.
Code examples
‘SDWELG05<cr>
‘SDWELG60<cr> set dwell time to 5 seconds set dwell time to 60 seconds
9.
CYCLE COUNT has feedback
This global serial command sets the number of cycles all triggers will have when activated. A cycle is equal to one sweep of any enabled inputs from 1-16 inclusive. range is 1-99
Code examples
‘SCYCLG05<cr>
‘SCYCLG99<cr> set to 5 cycles set to 99 cycles
10.
HARDWARE TRIGGER ENABLE / DISABLE has feedback
This serial command individually enables or disables the hardware trigger control inputs.
Serial commands not affected.
Code examples
‘SHT1SG00<cr>
‘SHT2CG00<cr>
‘SHT3SG00<cr>
‘SHT4CG00<cr> enable hardware trigger 1 disable hardware trigger 2 enable hardware trigger 3 disable hardware trigger 4
11.
VERSION REQUEST has feedback
This serial command will give a response with the software version of all video cards
Code example
‘GVERSG00<cr>
Response
‘A0VIDV1.1
‘A1VIDV1.1
get software version number first card second card
- 83 -
Suite 16 ASCII Codes
Preamplifier Codes
STRING
FUNCTION
INPUT UP
INPUT DOWN
INPUT 1
INPUT 2
INPUT 3
INPUT 4
INPUT 5
INPUT 6
INPUT 7
INPUT 8
INPUT 9
INPUT 10
INPUT 11
INPUT 12
INPUT 13
INPUT 14
INPUT 15
INPUT 16
MUTE TOGGLE
MUTE ON
MUTE OFF
ROOM OFF
VOLUME UP
VOLUME DN
BASS UP
BASS DN
TREBLE UP
TREBLE DN
TONE RECALL 1
TONE RECALL 2
TONE RECALL 3
TONE RECALL 4
TONE STORE 1
TONE STORE 2
TONE STORE 3
TONE STORE 4
VOLUME RECALL 1
VOLUME RECALL 2
VOLUME RECALL 3
VOLUME RECALL 4
VOLUME STORE 1
VOLUME STORE 2
VOLUME STORE 3
VOLUME STORE 4
LOUDNESS ON
LOUDNESS OFF
STEREO ENHANCE ON
STEREO ENHANCE OFF
VOLUME DIRECT
BASS DIRECT
TREBLE DIRECT
STEREO
MONO INPUT L
MONO INPUT R
BALANCE LEFT
BALANCE RIGHT
BALANCE EQUAL
BALANCE RECALL 1
BALANCE RECALL 2
BALANCE STORE 1
BALANCE STORE 2
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
START ACTION PREFIX
CHARACTER DO (SET) GET
S
S
S
S
S
S
G
G
G
G
G
G
S
S
S
S
S
S
S
S
S
S
S
S
S
G
G
G
G
G
G
G
G
G
G
G
G
G
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
TNR4
TNS1
TNS2
TNS3
TNS4
VLR1
VLR2
VLR3
VLR4
VLS1
VLS2
VLS3
VLS4
MTON
MTOF
RMOF
VLUP
VLDN
BSUP
BSDN
TRUP
TRDN
TNR1
TNR2
TNR3
LDON
LDOF
SEON
SEOF
V0##
B###
T###
STRO
MINL
MINR
BALL
BALR
BLEQ
BLR1
BLR2
BLS1
BLS2
PART 2
FUNCTION
INUP
INDN
AD01
AD02
AD03
AD04
AD05
AD06
AD07
AD08
AD09
AD10
AD11
AD12
AD13
AD14
AD15
AD16
MTOG
GLOBAL
R01
R01
R01
R01
R01
R01
R01
R01
R01
R01
R01
R01
R01
R01
R01
R01
R01
R01
R01
R01
R01
R01
R01
R01
R01
R01
R01
R01
R01
R01
R01
R01
R01
R01
R01
R01
R01
R01
R01
R01
R01
R01
R01
R01
R01
R01
R01
R01
R01
R01
R01
R01
R01
R01
R01
PART 3
R01 TO R99
R01
R01
R01
R01
R01
R01
- 84 -
Preamplifier Codes (cont.)
INPUT LEVEL TRIM 1
INPUT LEVEL TRIM 2
INPUT LEVEL TRIM 3
INPUT LEVEL TRIM 4
INPUT LEVEL TRIM 5
INPUT LEVEL TRIM 6
INPUT LEVEL TRIM 7
INPUT LEVEL TRIM 8
INPUT LEVEL TRIM 9
INPUT LEVEL TRIM 10
INPUT LEVEL TRIM 11
INPUT LEVEL TRIM 12
INPUT LEVEL TRIM 13
INPUT LEVEL TRIM 14
INPUT LEVEL TRIM 15
INPUT LEVEL TRIM 16
ALL OFF
PARTY SET 1
PARTY SET 2
PARTY SET 3
PARTY SET 4
PARTY CLEAR 1
PARTY CLEAR 2
PARTY CLEAR 3
PARTY CLEAR 4
PARTY 1
PARTY 2
PARTY 3
PARTY 4
PAGE VOLUME PRESET
PAGE ENABLE GROUP 1
PAGE ENABLE GROUP 2
PAGE ENABLE GROUP 3
PAGE ENABLE GROUP 4
PAGE ENABLE GROUP 5
PAGE ENABLE GROUP 6
PAGE ENABLE GROUP 7
PAGE ENABLE GROUP 8
PAGE DISABLE GROUP 1
PAGE DISABLE GROUP 2
PAGE DISABLE GROUP 3
PAGE DISABLE GROUP 4
PAGE DISABLE GROUP 5
PAGE DISABLE GROUP 6
PAGE DISABLE GROUP 7
PAGE DISABLE GROUP 8
AUTO PAGE ON
AUTO PAGE OFF
PAGE DIRECT
PAGE GROUP 1
PAGE GROUP 2
PAGE GROUP 3
PAGE GROUP 4
PAGE GROUP 5
PAGE GROUP 6
PAGE OFF
AUTO PAGE (audio level activated)
MANUAL PAGE (contact closure activated)
MAXIMUM VOLUME LEVEL
RESTORE FACTORY DEFAULTS
ALL UPDATE
ROOM UPDATE
ALL ROOM CONTROL UPDATE
ROOM CONTROL UPDATE
VERSION REQUEST
ECHO
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
‘
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
E
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
MV##
FDEF
ALRM
ROOM
ALRC
RCON
G VERS
# of bytes to follow 1-255
PGC2
PGC3
PGC4
PGC5
PGC6
PGC7
PGC8
PAON
PAOF
PDON
P1ON
P2ON
P3ON
P4ON
P5ON
P6ON
PGOF
PTY2
PTY3
PTY4
PV##
PGS1
PGS2
PGS3
PGS4
PGS5
PGS6
PGS7
PGS8
PGC1
IT14
IT15
IT16
ALOF
PTS1
PTS2
PTS3
PTS4
PTC1
PTC2
PTC3
PTC4
PTY1
IT08
IT09
IT10
IT11
IT12
IT13
IT01
IT02
IT03
IT04
IT05
IT06
IT07
G##
G##
G##
G##
G##
G##
G##
G##
G##
G##
G##
G##
G##
G##
G##
G##
G00
G##
G##
G##
G##
G00
G00
G##
G00
G00
G00
G00
G00
G00
G00
R01
G00
G00
G00
G00 bytes to be sent
R01
R01
R01
R01
R01
R01
R01
R01
R01
R01
R01
R01
R01
R01
R01
R01
R01
R01
R01
R01
R01
R01
R01
R01
R01
R01
R01
- 85 -
Video Switching Codes V-16 V1.1 and V1.2
Suite 16 Video card Protocol V1.1
SET VIDEO FOLLOWING
VIDEO TRACKS AUDIO INPUT
VIDEO TRACKS NOTHING (GOES OFF)
Get curent following setting for input
VIDEO DIRECT
SELECT A VIDEO INPUT
TURN VIDEO OFF
Get current video input
TRIGGER INPUT ASSIGNMENT
ASSIGN INPUT # TO TRIGGER #
DISABLE INPUT # FROM TRIGGER #
Get current input assignment for input
TRIGGER OUTPUT ASSIGNMENT
ASSIGN OUTPUT # TO TRIGGER #
DISABLE OUPUT # FROM TRIGGER #
Get current output assigment for output
HARDWARE TRIGGERS
Software activation of hardware trigger
HARDWARE TRIGGERS ENABLES
ENABLE HARDWARE TRIGGER
DISABLE HARDWARE TRIGGER
Get current hradware trigger enable status
DWELL TIME
DWELL TIME FOR ALL TRIGGERS
Get current dwell time setting
CYCLE COUNT
CYCLE COUNT FOR ALL TRIGGERS
Get current cycle setting
START SET/GET INPUT FUNCTION
‘
‘
‘
S
S
G
FS
FC
FS or FC
START SET/GET INPUT FUNCTION
‘ S VD
‘
‘ S
G
VD
VD
START SET/GET
‘
‘
‘
S
S
G
FUNCTIOIN
HI
HI
HI
01 - 16
INPUT #
01
01
01
01 - 16
INPUT #
01
00
00
OUTPUT FUNCTION
R
R
R
OUTPUT FUNCTION
R
R
R
1 - 5 01 - 16
TRIGGER # CLEAR/ SET GLOBAL INPUT #
1 SG 01
1
1
CG
SG or CG
01
01
01 - 96
ROOM #
01
01
01
01 - 96
ROOM #
01
01
01
START SET/GET
‘
‘
‘
S
S
G
FUNCTION
HO
HO
HO
CLEAR/ SET
SR
CR
SR or CR
01 - 16
ROOM #
01
01
01
START
‘
START SET/GET
‘
‘
‘
SET/GET
S
S
S
G
FUNCTION
TRG
FUNCTION
HTS
HTC
HTS or HTC
TRIGGER#
1
1
1
1 - 5
TRIGGER#
1
1 - 5
TRIGGER#
1
1
1
GLOBAL
G
GLOBAL
G
G
G
00
START
‘
‘
START
‘
‘
SET/GET
S
G
SET/GET
S
G
FUNCTIOIN
DWEL
DWEL
FUNCTIOIN
CYCL
CYCL
GLOBAL
G
G
GLOBAL
G
G
00
00
00
01 - 60
SEC.
01
01
01 - 99
CYCLES
01
01
VERSION REQUEST ‘ G VERS G 00
- 86 -
Appendix A - MC-5000 Setup Flow Charts
AUX
DVD
DSS
CD2
CD1
AM
FM2
FM1
AUX
DVD
DSS
CD2
CD1
AM
FM2
FM1
- 87 -
AUX
DVD
DSS
CD2
CD1
AM
FM2
FM1
- 88 -
AUX
DVD
DSS
CD2
CD1
AM
FM2
FM1
- 89 -
AUX
DVD
DSS
CD2
CD1
AM
FM2
FM1
AUX
DVD
DSS
CD2
CD1
AM
FM2
FM1
- 90 -
AUX
DVD
DSS
CD2
CD1
AM
FM2
FM1
AUX
DVD
DSS
CD2
CD1
AM
FM2
FM1
- 91 -
AUX
DVD
DSS
CD2
CD1
AM
FM2
FM1
- 92 -
AUX
DVD
DSS
CD2
CD1
AM
FM
2
FM1
AUX
DVD
DSS
CD2
CD1
AM
FM2
FM1
- 93 -
Appendix B - System Specifications
AVP-16 Size & Weight (with A-16, P-16, & V-16 Modules)
Width: 19” EIA Rack Mount Height: 5.25” (3 Rack Spaces) Depth: 20”
Weight: 26 lbs
Electrical Specifications
RCA Inputs: 47K
Ω Normal Input Volt.: 2V
Maximum Input Volt: 2.8V
Balanced Paging Input: 600
Ω Normal Input Volt.: 1V
Trigger Voltage Input: 3-24V AC or DC Isolated
Output Voltage:
Source Trigger: 12VDC Max. Source All On: 300mA
Zone Triggers: 12VDC Max. Zone All On: 300mA
Audio Output Impedance: 50
Ω Variable & Fixed
Unity 0dB Fixed Output Gain:
AC Power:
Inlet/Outlet: IEC-320
Input Voltage: 120V or 240V, 50-60Hz
Input Power: Max. 250W Fused
Typical Power: (1 x A-16, 1 x P-16, & 1 x V-16 {no Bus power}) = 45W
Max. Bus Power: 6 Amps @ 22VDC Unregulated
Max. Bus Power @ WH-3000/2000: 150mA typical at each port
MC-5011: Typical 45mA (Depending on LED settings)
MC-5000: Typical 60mA (Depending on LED settings)
Switched AC Outlet: IEC-320, 8 Amps Max.
- 94 -
Appendix C - 9 Pin D Connector Information
The following diagram indicates the pin connections for the 9-pin D connectors on used for zone low voltage triggering.
The P-16 Preamplifier Module, the PTM-1225 and the PTM-1260 all feature female jacks with the same pin configurations.
The DB-9 Termination Block or 9-Pin Ribbon Cable use male connectors that are diagrammed below.
Female Connector
(on P-16 & PTM-1260)
Zone 6/Ch 6
Zone 5/Ch 5
Zone 4/Ch 4
Zone 3/Ch 3
Gnd
Zone 1/Ch 1
Zone 2/Ch 2
Male Connector
(on DB-9 or Ribbon Cable)
Pin 1/Gnd
Pin 6/Zone 1/Ch 1
Pin 7/Zone 2/Ch 2
Pin 4/Zone 6/Ch 6
Pin 5/Zone 5/Ch 5
Pin 9/Zone 4/Ch 4
Pin 8/Zone 3/Ch 3
- 95 -
Download
Advertisement
Key features
Modular design allows for customization
Expands up to 48 sources and 48 zones
High-quality audio and video performance
Easy to use and install
Versatile control options
Cost-effective
Integrates with other home automation systems
Frequently asked questions
The Ada Suite-16 can expand up to 48 sources and 48 zones.
The Ada Suite-16 can be controlled via IR, RF, RS-232, and Ethernet.
Yes, the Ada Suite-16 can integrate with other home automation systems via RS-232 or Ethernet.