Imagine Communications Nexio G8 Broadcast Video Servers Application Note
PDF
Document
Advertentie
Advertentie
Application Note Serial Port Trigger Support 3/28/2014 175-100341-00 Serial Port Trigger Support Application Note Publication Information © 2014 Imagine Communications. Proprietary and Confidential. Imagine Communications considers this document and its contents to be proprietary and confidential. Except for making a reasonable number of copies for your own internal use, you may not reproduce this publication, or any part thereof, in any form, by any method, for any purpose, or in any language other than English without the written consent of Imagine Communications. All others uses are illegal. This publication is designed to assist in the use of the product as it exists on the date of publication of this manual, and may not reflect the product at the current time or an unknown time in the future. This publication does not in any way warrant description accuracy or guarantee the use for the product to which it refers. Imagine Communications reserves the right, without notice to make such changes in equipment, design, specifications, components, or documentation as progress may warrant to improve the performance of the product. Trademarks Nexio® and Nexio® G8™ are trademarks or trade names of Imagine Communications or its subsidiaries. Microsoft® and Windows® are registered trademarks of Microsoft Corporation. All other trademarks and trade names are the property of their respective companies. Contact Information Imagine Communications has office locations around the world. For domestic and international location and contact information, visit our Contact page (http://www.imaginecommunications.com/company/contact-us.aspx). Support Contact Information For domestic and international support contact information see: Support Contacts (http://www.imaginecommunications.com/services/technical-support.aspx) eCustomer Portal (http://support.imaginecommunications.com) © 2014 Imagine Communications. Proprietary and Confidential. 3/28/2014 | Page 2 Serial Port Trigger Support Application Note Serial Port Trigger Support Serial Port Trigger Support Nexio® G8™ products support serial port triggers for automation or presentation systems. Serial port trigger support is limited to selecting and outputting layouts both offline and online only, and does not include the ability to change layout content in any way. Benefit The serial port trigger allows you to display playlist events or Media Store database resources in any order via a CII formatted message on the serial port. The format of the serial port command is that of the Drake, Phillips, or Probel protocol. Using the protocol, your Nexio® G-Series product can be commanded to display events, making it easy to cover live events like town council meetings or legislative assemblies. This kind of serial command is often available with equipment commonly used in presentation control like that offered by companies like Crestron. As you need playlist events or Media Store resources, you can send them to air from the playlist by the event number (if the number is less than 1000) or from an available Media Store database (if the number is greater than 1000). A useful utility called the News Feed Simulator is provided to verify COM port communications and test the serial communications procedure. You can also use the News Feed Simulator to send commands to output events. Hardware Support Standard RS-232 or RS-422 serial port communication protocols are supported. A null modem cable is required. TCP/IP Ethernet networking control is not supported. Configure COM Port Settings Before using the serial port trigger, review the settings in your Nexio® product inscribe.ini file. 1. 2. 3. 4. Close your Nexio® product. Open the inscribe.ini file, which is in your Nexio® product folder. Find the INFINIT section. Modify the serial port trigger support settings if required. In most cases, use the default values. ComPort=COM1 Baud=9600 DataBits=8 Parity=None © 2014 Imagine Communications. Proprietary and Confidential. 3/28/2014 | Page 3 Serial Port Trigger Support Application Note Serial Port Trigger Support StopBits=1 Note: If you are also using a GPI trigger, the ComPort entry must be assigned a COM port different from the GPI trigger COM port. (To check the GPI port assignment, open the Preferences dialog and switch to the Sequencer tab.) 5. Save the inscribe.ini file. Install the News Feed Simulator After you have configured your Nexio® product, install the News Feed Simulator, which you can use to verify COM port communications and test the serial communications procedure. Note: You must install the News Feed Simulator on a computer different from the system running your Nexio® product. To install the News Feed Simulator: 1. Double-click the News Feed Simulator.exe file on your Nexio® product CD. 2. During the installation select the COM port for the serial port trigger. If you need to change the COM port setting after installation, you can select a different COM port on the Preferences tab in News Feed Simulator. After installing the News Feed Simulator, connect the two computer systems with a null modem cable attached to serial ports. It is possible to use the News Feed Simulator without the recommended hardware setup, but other hardware configurations are not guaranteed to work successfully. Enable/Disable Serial Port Trigger Support You can enable or disable serial port trigger support at any time in your Nexio® product. It is recommended that you disable serial port trigger support in your Nexio® product when no serial port trigger is being used. By default, serial port trigger support is disabled. 1. In your Nexio® product, select File > Preferences to open the Preferences dialog. 2. Switch to the General tab. 3. Enable or disable serial port trigger support. To enable support, select the External Serial Control checkbox. To disable support, clear the External Serial Control checkbox. 4. Click OK. You must close and restart your Nexio® product to see the changes made in the Preferences dialog. © 2014 Imagine Communications. Proprietary and Confidential. 3/28/2014 | Page 4 Serial Port Trigger Support Application Note Serial Port Trigger Support Use the News Feed Simulator You can use the News Feed Simulator to test serial port communication. The News Feed Simulator sends and receives commands via the serial port. 1. Open the News Feed Simulator by double-clicking the News Feed Simulator icon on your desktop. You can also launch the News Feed Simulator from the Windows Start menu (Start > All Programs > Harris > Inscriber News Feed Simulator > News Feed Simulator). 2. In the News Feed Simulator, switch to the Preferences tab. 3. On the Preferences tab, select the Serial Port option. 4. Click the Set button beside the Serial Port option. 5. In the Com Port Settings dialog, review the port’s communications settings and then click OK. 6. On your Nexio® product system, manually open a playlist (.scribelist file) by opening your Nexio® product and selecting File > Open, and then navigating to and selecting a .scribelist file containing layouts. 7. In the News Feed Simulator, switch to the Test Interface tab. 8. Select the CR and LF checkboxes to automatically add carriage return and line feed data to the end of each command line. 9. Enter a single CII command or list of CII commands to send to your Nexio® product system. A list of available commands is described in the following table. Single Command - In the Line Command window, enter a CII command, and then press ENTER or click the adjacent Send button. Only the top Send button executes a command you enter in the Line Command window. List of Commands - In the List Command window, enter a list of CII commands, and then double-click in the window or click the adjacent Send button. Only the bottom Send button executes commands in the List Command window. Action CII Command © 2014 Imagine Communications. Description Proprietary and Confidential. 3/28/2014 | Page 5 Serial Port Trigger Support Application Note Serial Port Trigger Support Action CII Command Description Take event from the playlist T\7\event#<1000\A\\ Outputs the event# that is less than 1000 to the program channel. You must replace event#<1000 with the actual event filename number that is less than 1000. Take event from T\7\event#>1000\A\\ currently selected Media Store database The application switches to the Media Store module and the event number that is greater than 1000 is output to the program channel. You must replace event#>1000 with the actual event filename number that is greater than 1000. Select an event in T\5\event#\\ the playlist for preview and preload Selects the event number in the currently loaded playlist. The selected event is loaded into CG but is not output to the program channel. You must replace event# with the actual event filename number. Take currently selected event in the playlist V\6\channel#\\ Outputs the currently selected event in the playlist. You must replace channel# with "0" to take to channel 1. Any event number higher than 1000 triggers and outputs the corresponding event number in the currently selected Media Store database. As you send commands, they display in the Command Reception window in the News Feed Simulator. Create a Log of Commands Received To help troubleshoot problems, you can log the commands that the Nexio® system receives. 1. On the Test Interface tab in the News Feed Simulator, click the File button and specify the location where you want the log file saved. 2. Click the Start button to begin logging. 3. Send commands from the News Feed Simulator. 4. Click the End button to finish logging. 5. When you are finished testing, click OK. The log file is saved automatically. © 2014 Imagine Communications. Proprietary and Confidential. 3/28/2014 | Page 6 Serial Port Trigger Support Application Note Serial Port Trigger Support Troubleshooting Is serial port trigger support enabled in the Nexio® product? To verify that the serial port trigger is enabled in your Nexio® product, complete the following steps. 1. 2. 3. 4. In your Nexio® product, select File > Preferences to open the Preferences dialog. Switch to the General tab. Ensure that the External Serial Control checkbox is selected. Click OK. Restart your Nexio® product to enable serial port trigger support. © 2014 Imagine Communications. Proprietary and Confidential. 3/28/2014 | Page 7 ">
/
Downloaden
Even een vriendelijke herinnering. U kunt het document hier bekijken. Maar het belangrijkste is dat onze AI het al heeft gelezen. Het kan complexe dingen in eenvoudige bewoordingen uitleggen, uw vragen in elke taal beantwoorden en u helpen snel te navigeren, zelfs in de langste of meest ingewikkelde documenten.
Advertentie