IR Quiet Fan Speed and Incandescent/
Halogen Dimmer Single-Location System
Canopy Module
CM-L300FQ1: 120 V~ 60 Hz
300 W light / 1 A fan (3.5 A total)
Wall Control
MIR-LFQ35: 120 V~ 60 Hz
3.5 A (one CM-L300FQ1)
Multigang Installations
When installing more than one control in the same wallbox, it may be necessary to remove all inner side sections prior to wiring (see below). Using pliers, bend side sections up and down until they break off. Repeat for each side section to be removed.
Note: Product does not require derating when side sections are removed.
Do not remove outside sections.
?
Technical Assistance
If you have questions concerning the installation or operation of this product, call the
Lutron Technical Support Center. Please provide exact model number when calling.
U.S.A. and Canada (24 hrs/7days):
1.800.523.9466
Other countries 8am – 8pm ET:
+1.610.282.3800
México
+1.888.235.2910
Fax +1.610.282.1243
http://www.lutron.com
Infrared Wireless Transmitter
MIR-ITFS-LF: 3 V 0.15 W
Warning: For use with one ceiling paddle fan and light only. Do not use with an exhaust fan or more than one fan.
One ceiling fan only No exhaust fans
Important Notes
Please read before installing.
1. Caution: To avoid overheating and possible damage to other equipment, do not use to control receptacles, fluorescent or neon lighting fixtures, transformer-supplied appliances, solid state fan motors, or exhaust fans. For exhaust fans use Lutron fully variable fan speed controls.
2. Install in accordance with all national and local electrical codes.
3. When no “grounding means” exist within the wallbox then the NEC
®
2005, Article 404.9
allows a wall control without a grounding connection to be installed as a replacement, as long as a plastic, noncombustible wallplate is used. For this type of installation, cap or remove the green ground wire on the wall control and use an appropriate wallplate such as
Lutron’s Claro
® series wallplates.
4. The Maestro
®
IR dual fan/light control system consists of a Wall Control and a Canopy
Module. Both must be installed correctly before attempting to control the fan/light fixture. Do not attempt to mix Lutron controls with those from other manufacturers, or mix Lutron controls not labeled for use together.
5. This system is not compatible with fans having a control system built into the motor.
6. Do not paint Wall Control or Canopy Module.
7. Do not use where total lamp wattage is less than 40 W or greater than 300 W.
8. Operate between 32 °F (0 °C) and 104 °F (40 °C) room temperature. For indoor use only.
9. Wall Control may feel warm to the touch during normal operation.
10. Recommended wallbox depth is 2.5 in (64 mm) minimum.
11. Clean Wall Control with a soft damp cloth only. Do not use any chemical cleaners.
12. This system cannot be used to change the direction of the fan. To change the fan direction, stop the fan, and then change the position of the switch located on the body of the fan.
13. To maximize light bulb life, use bulbs recommended for fan or “rough service” use.
14. Do not use pull chains to operate fan/light after installing this system.
15. Canopy Module must be installed within a fan canopy enclosure.
16. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Breaking Side
Sections
Inside sections are removed from each control
Side sections are removed from both sides of middle control
Operation
Light Level Tap Button
• Tap once when lights are off -
Lights brighten smoothly to preset intensity.
• Tap once when lights are on -
Lights dim smoothly to off.
• Tap twice quickly - Lights brighten rapidly to full intensity.
• Press and hold when lights are on
- Activates delayed fade to off mode.
As the tap button is held, the LEDs will begin to flash. The first flashing
LED represents a 10 second fade to
OFF. Each additional flashing LED represents an additional 10 seconds of delay before lights fade to OFF (up to 60 seconds of delay).
Fan Speed Tap Button
• Tap once when fan is off - Fan speed increases to preset level.
• Tap once when fan is on - Fan speed slows to off.
• Tap twice quickly - Fan speed increases to full speed.
Light Level LEDs
Indicate approximate light level
LEDs may not change with each press
Press to increase light level
Press to decrease light level
Fan speed LEDs
Indicate exact fan speed
LEDs will change with each press
Press to increase fan speed
Press to decrease fan speed
(LEDs not available on Accessory Controls)
FASS
TM
- Front
Accessible
Service Switch
IMPORTANT NOTICE:
To replace bulb, remove power by pulling the FASS switch out on the Control.
For any procedure other than routine bulb replacement, power must be disconnected at the main electrical panel.
Troubleshooting
Symptom
Light or fan does not turn ON or no LEDs turn ON.
Upper LEDs on Wall Control cycle rapidly and bottom LED is ON.
Upper LEDs on Wall Control cycle rapidly and second lowest LED is ON.
Fan vibrates or wobbles.
Light dims in large steps and fan is noisy or does not spin at correct speed.
Light button controls fan and vice-versa.
Fan speeds too slow.
Wall Control LEDs respond as expected but fan and/or light does not respond properly.
Light or fan does not respond to infrared wireless transmitter.
Possible Cause
•Front Accessible Service Switch ( FASS) on control is pulled out to the OFF position.
•Manual switch on fan is off (ex: pull chain).
•Light bulb(s) burned out.
•Breaker is OFF or tripped (or fuse blown).
•Fan direction switch is between forward and reverse.
•Wiring error, call Lutron Technical Support
Center at 1.800.523.9466.
•Unit is not activated properly. Activate system as described in Step 14.
•Wiring error, call Lutron Technical Support
Center at 1.800.523.9466.
•Communication error. Check wiring; if error continues, call Lutron Technical Support
Center at 1.800.523.9466.
•Fan blades not properly balanced. See fan manufacturer's instructions.
•Fan and light control wires on Canopy Module are reversed.
•Fan and light control wires on Canopy Module are reversed.
•Fan pull chain not set to high.
•Fan and/or light pull chains not set to high/on.
•Wiring error, call Lutron Technical Support
Center at 1.800.523.9466.
•Transmitter batteries installed incorrectly.
•Transmitter batteries are dead.
•Transmitter not aimed directly at wall control.
•Transmitter outside operating range.
•Wall control has already received and responded to command.
Reference Wiring Diagram
Neutral
Live
120 V~
60 Hz
Switched Live
White
Black
Wallbox
Canopy
Module
Red (Light)
Yellow (Fan)
Junction box and Canopy
Wall
Control
Brass
Green
Brass
Ground
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Limited Warranty
Ceiling Fan and Light
(Valid only in U.S.A., Canada, Puerto Rico, and the Caribbean.)
Lutron will, at its option, repair or replace any unit that is defective in materials or manufacture within one year after purchase.
For warranty service, return unit to place of purchase or mail to Lutron at 7200 Suter Rd., Coopersburg, PA 18036-1299, postage pre-paid.
THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES, AND THE IMPLIED WARRANTY OF MERCHANTABILITY
IS LIMITED TO ONE YEAR FROM PURCHASE. THIS WARRANTY DOES NOT COVER THE COST OF INSTALLATION, REMOVAL OR
REINSTALLATION, OR DAMAGE RESULTING FROM MISUSE, ABUSE, OR DAMAGE FROM IMPROPER WIRING OR
INSTALLATION. THIS WARRANTY DOES NOT COVER INCIDENTAL OR CONSEQUENTIAL DAMAGES. LUTRON’S LIABILITY ON
ANY CLAIM FOR DAMAGES ARISING OUT OF OR IN CONNECTION WITH THE MANUFACTURE, SALE, INSTALLATION,
DELIVERY, OR USE OF THE UNIT SHALL NEVER EXCEED THE PURCHASE PRICE OF THE UNIT.
This warranty gives you specific legal rights, and you may have other rights which vary from state to state. Some states do not allow the exclusion or limitation of incidental or consequential damages, or limitation on how long an implied warranty may last, so the above limitations may not apply to you.
Lutron, Claro, Maestro, and Maestro IR are registered trademarks and FASS is a trademark of Lutron
Electronics Co., Inc. NEC is a registered trademark of the National Fire Protection Association, Quincy, Massachusetts.
© 2010 Lutron Electronics Co., Inc.
Infrared Wireless Transmitter Operation
Point the transmitter at the Maestro IR
®
Wall Control(s), then use the buttons as outlined below.
LIGHT ON FULL:
Tap once: lights brighten smoothly to full intensity.
LIGHT OFF:
Tap once: 3 second fade to off
Press and hold: 10–60 second delayed fade to off.
FAN ON FULL:
Fan speed increases to full speed.
FAN OFF:
Fan speed slows to off.
FAN FAVORITE LEVEL:
Tap once to recall your favorite fan speed.
To store your favorite level, press and hold for about 3 seconds until the wall control
LED begins to flash. (“Off” is a valid preset level.)
LIGHT RAISE:
Press to increase light level
LIGHT LOWER:
Press to decrease light level
LIGHT FAVORITE LEVEL:
Tap once to recall your favorite light level.
To store your favorite speed, press and hold for about 3 seconds until the wall control LED begins to flash.
(“Off” is a valid preset level.)
FAN RAISE:
Press to increase fan speed
FAN LOWER:
Press to decrease fan speed
This transmitter is compatible with most learning remote controls.
Please see the learning remote control manufacturer’s instructions for programming information.
Multiple Gang Application
Maestro IR
® fan controls may be ganged together with Maestro IR
® dimmers, but should not be ganged with other Maestro IR
® fan or fan/light controls. If ganged with
Maestro IR
® dimmers, button presses on a Dimmer IR transmitter will affect all light controls; button presses on a Fan IR transmitter will affect only the fan control.
• Pressing the ON FULL button will cause each control to fade to its highest level, regardless of whether some are on and some are off.
• Pressing the OFF button will cause all controls to turn off.
• Pressing the RAISE or LOWER buttons will change the control level on all units at the same rate until the button is released or until the controls have reached their maximum or minimum level. If any units are off when the RAISE button is pressed, they will turn on at the minimum control level.
• To save your favorite control level, adjust all the controls to the desired level, then press and hold the FAVORITE button for about 3 seconds until the LEDs begin to flash. Once your favorite level is set, pressing the FAVORITE button will cause each control to return to your programmed favorite level.
Battery Replacement
The Infrared Wireless Transmitter uses 2 AAA batteries that are pre-installed. For best results use alkaline batteries. Do not use NiCad or NiMH batteries.
To replace batteries:
1. Remove the battery cover (see diagram).
2. Replace with 2 size AAA batteries as shown.
Note: Incorrect installation will cause batteries to drain.
3. Replace the battery cover.
Push on arrow, slide and lift off battery cover.
Lutron Electronics Co., Inc.
7200 Suter Road
Coopersburg, PA 18036-1299, U.S.A.
Made and printed in the U.S.A. 11/10 P/N 033-217 Rev. A
Lutron Technical Support Center 1.800.523.9466 24 hrs / 7 days www.lutron.com
Canopy Module Installation
1
Install fan.
• Install fan according to manufacturer's instructions and check for proper operation.
6
Insert Canopy Module.
6a - Down Rod Bracket
• Do not install Canopy Module in ceiling.
• Slide Canopy Module into the ceiling fan mounting bracket.
To junction box 2
Set fan speed and lights.
• Set fan to highest speed and turn lights on using pull chains.
• If two switches control the fan and light separately, note which controls the light.
3
Turn OFF power.
• Turn power OFF at circuit breaker (or remove fuse).
4
Disconnect fan.
• Remove canopy enclosure from ceiling fan mounting bracket.
• If separate wires from the junction box power the fan and light, tag the wire connected to the light wire. In Step 5, connect this wire to the black Canopy Module wire.
• Leave any green ground wires connected as directed in fan manufacturer's instructions.
• Disconnect fan from remaining wiring in the ceiling.
Black
Black with White stripe or Blue
White
Typical Wire Colors
Fan
Light
Neutral
If the fan and light do not have separate wires, the fixture may have a control system built into the motor and cannot be used with this product.
To junction box To junction box
6b - Flush Mount Bracket
• Do not install Canopy Module in ceiling.
• Attach Canopy Module to bracket with a cable tie.
• Ensure cable tie does not come in contact with moving motor parts.
• Install cable tie through notches on Canopy Module. Pull tight and clip excess.
To junction box
Notch
Cable tie
Mounting bracket
Canopy enclosure
Down Rod Bracket Flush Mount Bracket
Important Wiring Information
When making wire connections, follow the recommended strip lengths and combinations for the supplied wire connectors (see wire connector bag).
Note: All wire connectors provided are suitable for copper wire only. For aluminum wire, consult an electrician.
Wire Connectors:
Use to join 14 or 12 AWG (1.5 or 2.5 mm²) ground wire to
18 AWG (0.75 mm²) Wall Control ground wire, and to join
18 AWG (0.75 mm²) Canopy Module wire to 12, 14, 16 or 18 AWG
(2.5, 1.5, 1.0 or 0.75 mm²) wire.
Twist wire connector tight.
7
Attach canopy.
7a - Down Rod Bracket
• Check all wire connections.
• Tuck the wires into the junction box and/or canopy enclosure.
• Attach the canopy enclosure to the fan mounting bracket, taking care not to pinch any wires.
To junction box
5
Connect Canopy Module.
• If you have questions about wiring, call the Lutron Technical Support Center at
1.800.523.9466.
To junction box
Switched Live
Black
White
Wiring the Canopy Module (CM-L300FQ1):
Use wire connectors to join wires as indicated below and in the wiring diagram, and to cap any unused
wires.
Neutral
Fan
Light
Yellow
Red
Canopy
Module Wire:
White
Black
Yellow
Red
Connects to:
Neutral wires in the junction box and to fan
Switched Live wire from
Wall Control
Fan
Light
To fixture
Canopy
Module
7b - Flush Mount Bracket
• Check all wire connections.
• Tuck the wires into the junction box and/or bracket.
• Ensure wires and/or wire connectors do not come in contact with moving motor parts.
• Attach the canopy enclosure to the fan mounting bracket, taking care not to pinch any wires.
To junction box
Control Installation
8
Remove original wallplate and switch.
• Remove the wallplate and switch mounting screws.
• Carefully remove switches from wall (do not remove wires).
Danger: Verify power to each switch is OFF before proceeding.
12
Mount Control(s) to wallbox.
• Form wires carefully into the wallbox, mount and align the Control(s).
• Replace the wallplate.
Align wall control and tighten screws.
Caution:
Do not overtighten mounting screws.
Snap on Claro wallplate.
9
Identify switch wires.
• If two switches control the fan and light separately, tag the wires connected to the light switch. In Step 11, connect these wires to the Wall Control.
Important Note:
Your wall switch may have two wires attached to the same screw (see illustrations below for examples). Tape these two wires together before disconnecting. When wiring, connect wires to new Controls the same way they were connected to the switch.
13
Turn ON power.
• Do not turn on power until Wall Control and Canopy Module have been installed and wired.
• Turn power ON at circuit breaker (or replace fuse).
Warning: Fan will return to full speed when power is restored. Clean up any tools or ladders near the fan first.
10
One wire in the push-in terminal and one to the screw.
Disconnect switch wires.
One continuous wire to the screw.
14
Activate system.
• Pull out the Front Accessible Service Switch ( FASS) at the bottom of the Wall Control, wait 10 seconds, then push it back in.
• The LEDs will cycle for up to 30 seconds.
• If installing more than one Wall Control/Canopy Module system, activate one at a time with FASS pushed in on all other systems.
Screw Terminals:
Turn screws to loosen.
Push-in Terminals:
Insert screwdriver.
Pull wire out.
Looped Wire:
Turn screw to loosen.
15
Recommended - Disconnect pull chains.
• Disconnect pull chain extensions to prevent light and fan speeds from being adjusted at the fan.
Important Wiring Information
Trim or strip wallbox wires to the length indicated by the strip gauge on the back of the control
Push-in Terminals: Insert wires fully.
NOTE: Push-in terminals are for use with 14 AWG (1.5 mm²) solid copper wire only.
DO NOT use stranded or twisted wire.
OR
Screw Terminals: Tighten securely.
Screw terminals are for use with 12 or 14 AWG (2.5 or 1.5 mm²) solid copper
wire only. DO NOT use stranded or twisted wire.
11
Connect Wall Control.
• For installations involving more than one control in a wallbox, refer to
Multigang Installations before beginning.
• Remove the wallplate before proceeding with installation. This will expose
Wall Control mounting holes and prevent wallplate damage while installing.
Grasp Claro wallplate at top and pull forward to remove.
Wall Control
Brass screw
Brass screw
Green wire
Ground
Wiring the Wall Control (MIR-LFQ35):
See reference wiring diagram (on reverse).
• Use wire connectors to connect the green ground wire on the Wall Control to the bare
copper or green ground wire in the wallbox
(see 4-Important Wiring Information).
• Connect either of the wires removed from the switch to one of the brass screw terminals on the Wall Control, or insert fully into the push-in terminal.
• Connect the remaining wire removed from the switch to the other brass screw terminal on the Wall Control, or insert fully into the push-in terminal.
• Cap any unused wires.