Lutron Electronics Maestro User Manual
Add to my manuals
2 Pages
Lutron Electronics Maestro is a quiet fan speed control system designed for use with ceiling paddle fans. It allows you to control the speed of up to four fans from a single location, and can be used in both single-pole and multi-location applications. The system includes a wall control, one to four canopy modules, and up to two accessory controls. The wall control features a simple tap interface that allows you to increase or decrease the fan speed, or turn the fan off. The canopy modules are installed inside the fan canopy and connect to the wall control wirelessly.
advertisement
Fan Speed
Control
®
English
P/N 033-214
Quiet Fan Speed Control Multi-Location
System
Canopy Module
CM-FQ1: 120 V~ 60 Hz
1.0 A fan
Wall Control
MA-FQ4M: 120 V~ 60 Hz
4.0 A (up to 4 CM-FQ1)
Accessory Control
MA-AFQ4: 120 V~ 60 Hz
4.0 A
Warning: For use with one to four ceiling paddle fans only. Do not use with an exhaust fan.
One to four ceiling fans only No exhaust fans
Multigang Installations
When installing more than one control in the same wallbox, it may be necessary to remove all inner side sections prior to wiring (see below). Using pliers, bend side sections up and down until they break off. Repeat for each side section to be removed.
when side sections are removed.
Note: Product does not require derating
Do not remove outside sections.
?
Technical Assistance
If you have questions concerning the installation or operation of this product, call the
Lutron Technical Support Center . Please provide exact model number when calling.
U.S.A. and Canada (24 hrs/7 days):
+1.800.523.9466
Other countries 8am – 8pm ET:
+1.610.282.3800
México
+1.888.235.2910
Fax +1.610.282.1243
http://www.lutron.com
Breaking Side
Sections
Operation
Tap Button
•
•
•
Tap once when fan is off Fan speed increases to preset level.
Tap once when fan is on Fan speed slows to off.
Tap twice quickly Fan speed increases to full speed.
LEDs
Indicate exact fan speed
LEDs will change with each press
(LEDs not available on Accessory Controls)
Inside sections are removed from each control
Side sections are removed from both sides of middle control
Reference Wiring Diagram
Neutral
Switched Live
White
Canopy
Module
Yellow (Fan)
Black
Press to increase fan speed
Press to decrease fan speed
Live
120 V~
60 Hz
FASS
- Front
Accessible
Service Switch
First Fan / Canopy Module
Wall
Control
Brass
Brass
Black
Green
Ground
Wallbox
See Step 12 for two- and three-location control wiring.
Up to 3
Additional
Fans / Canopy
Modules
(up to 4 total)
Important Notes
Please read before installing.
5.
6.
7.
8.
1. Caution: To avoid overheating and possible damage to other equipment, do not use to control receptacles, lighting fixtures, transformer-supplied appliances, solid state fan motors, or
2.
3.
exhaust fans . For exhaust fans use Lutron fully variable fan speed controls.
Install in accordance with all national and local electrical codes.
When no “grounding means” exist within the wallbox then the NEC
®
2002, Article 404-9 allows a wall control without a grounding connection to be installed as a replacement, as long as a
4.
plastic, noncombustible wallplate is used. For this type of installation, cap or remove the green ground wire on the wall control and use an appropriate wallplate such as Lutron’s Claro
® or
Satin Colors
The
TM
Maestro
® series wallplates.
fan speed control system consists of a Wall Control, one to four Canopy
Modules, and up to two Accessory Controls. All must be installed correctly before attempting to control the fans. Do not attempt to mix Lutron controls with those from other manufacturers, or mix Lutron controls not labeled for use together.
.
Do not paint Wall Control, Canopy Module, or Accessory Control.
Maestro Controls are not compatible with standard 3-way/4-way switches.
Accessory Controls (MA-AFQ4) cannot be used individually and must be used in conjunction with a Maestro Wall Control (MA-FQ4M) in a 3-way/4-way application.
In any 3-way/4-way circuit use only one Wall Control (MA-FQ4M) with up to 2 Accessory 9.
10.
11.
12.
14.
Controls (MA-AFQ4).
Operate between 32 °F (0 °C) and 104 °F (40 °C) room temperature. For indoor use only.
Wall Control and Accessory Controls may feel warm to the touch during normal operation.
Recommended wallbox depth is 2.5 in (64mm) minimum.
13. Clean controls with a
15.
16.
17.
soft damp cloth only .
Do not use any chemical cleaners.
This system cannot be used to change the direction of the fan. To change the fan direction, stop the fan, and then change the position of the switch located on the body of the fan.
Do not use pull chains to operate fan(s) after installing this system.
Each Canop y Module must be installed within a fan canopy enclosure.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:(1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Troubleshooting
Symptom
Fan does not turn ON or no LEDs turn ON.
LEDs on Wall Control cycle rapidly and bottom LED is ON.
LEDs on Wall Control cycle rapidly and second lowest LED is ON.
Fan vibrates or wobbles.
Fan speeds too slow.
Wall Control LEDs respond as expected but fan does not respond properly.
Possible Cause
•Front Accessible Service Switch ( FASS ) on control is pulled out to the OFF position.
•Manual switch on fan is off (ex: pull chain).
•Breaker is OFF or tripped (or fuse blown).
•Fan direction switch is between forward and reverse.
•Wiring error, call Lutron Technical Support
Center at +1.800.523.9466.
•Unit is not activated properly. Activate system as described in Step 15.
•Wiring error, call Lutron Technical Support
Center at +1.800.523.9466.
•Communication error. Check wiring; if error continues, call
Center
Lutron Technical Support at +1.800.523.9466.
•Fan blades not properly balanced. See fan manufacturer's instructions.
• Fan pull chain not set to high.
• Fan pull chain not set to high.
• Wiring error, call
Center
Lutron Technical Support at +1.800.523.9466.
Lutron Technical Support Center
1.800.523.9466 24 hrs / 7 days www.lutron.com
Canopy Module Installation
1
Install fan(s).
• Install fan(s) according to manufacturer's instructions and check for proper operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Down Rod Bracket
Important Wiring Information
Flush Mount Bracket
When making wire connections, follow the recommended strip lengths and combinations for the supplied wire connectors (see wire connector bag).
Note: All wire connectors provided are suitable for copper wire only.
For aluminum wire, consult an electrician.
Wire Connectors:
Use to join 1.5 or 2.5 mm² (14 or 12 AWG) ground wire to 0.75 mm²
(18 AWG) Wall Control ground wire, and to join 0.75 mm² (18 AWG)
Canopy Module wire to 2.5, 1.5, 1.0 or 0.75 mm²
(12, 14, 16 or 18 AWG) wire.
Twist wire connector tight.
Limited Warranty
(Valid only in U.S.A., Canada, Puerto Rico, and the Caribbean.)
Lutron will, at its option, repair or replace any unit that is defective in materials or manufacture within one year after purchase. For warranty service, return unit to place of purchase or mail to Lutron at 7200 Suter Rd., Coopersburg, PA 18036-1299, postage prepaid.
THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES, AND THE IMPLIED WARRANTY OF
MERCHANTABILITY IS LIMITED TO ONE YEAR FROM PURCHASE. THIS WARRANTY DOES NOT COVER THE COST OF
INSTALLATION, REMOVAL OR REINST ALLATION, OR DAMAGE RESULTING FROM MISUSE, ABUSE, OR DAMAGE FROM
IMPROPER WIRING OR INSTALLATION. THIS WARRANTY DOES NOT COVER INCIDENTAL OR CONSEQUENTIAL
DAMAGES. LUTRON’S LIABILITY ON ANY CLAIM FOR DAMAGES ARISING OUT OF OR IN CONNECTION WITH THE
MANUFACTURE, SALE, INSTALLATION, DELIVERY, OR USE OF THE UNIT SHALL NEVER EXCEED THE PURCHASE PRICE
OF THE UNIT.
This warranty gives you specific legal rights, and you may have other rights which vary from state to state. Some states do not allow the exclusion or limitation of incidental or consequential damages, or limitation on how long an implied warranty may last, so the above limitations may not apply to you.
Lutron, Claro, and Maestro are registered trademarks and FASS and Satin Colors are trademarks of Lutron Electronics Co., Inc.
NEC is a registered trademark of the National Fire Protection Association, Quincy, Massachusetts.
© 2010 Lutron Electronics Co., Inc.
Lutron Electronics Co., Inc.
7200 Suter Road
Coopersburg, PA 18036-1299, U.S.A.
Made and printed in the U.S.A. 11/10 P/N 033-214 Rev. A
2
3
4
Note: Up to four ceiling fans can be controlled on one circuit.
Follow steps 4–7 for each fan.
Disconnect fan.
• Remove canopy enclosure from ceiling fan mounting bracket.
• Leave any green ground wires connected as directed in fan manufacturer's instructions.
• Disconnect fan from remaining wiring in the ceiling.
5
Set fan speed.
• Set fan(s) to highest speed using pull chains.
•
Turn OFF power.
Turn power OFF at circuit breaker (or remove fuse).
Fan
Neutral
Black
White
To junction box
Typical Wire Colors
Mounting bracket
Canopy enclosure
To junction box
Connect Canopy Module(s).
Switched
Live to additional fans
Fan
To junction box
Switched
Live
Black
Canopy
Module
To fixture
Neutral
Yellow
White at +1.800.523.9466.
Wiring the Canopy Module (CM-FQ1):
Use wire connectors to join wires as indicated below and in the wiring diagram, and to wires .
Connects to: Canopy
Module Wire:
White
Black
Yellow
Neutral wires in the junction box and to fan
Switched Live wire(s) from
Wall Control and to additional fan(s)
Fan
Lutron Technical Support Center 1.800.523.9466 24 hrs / 7 days www.lutron.com
6
Insert Canopy Module.
6a - Down Rod Bracket
• Do not install Canopy Module in ceiling.
• Slide Canopy Module into the ceiling fan mounting bracket.
To junction box
Control Installation
8
Remove original wallplate and switch.
• Remove the wallplate and switch mounting screws.
• Carefully remove switches from wall (do not remove wires) .
Danger: Verify power to each switch is OFF before proceeding.
Important Wiring Information
Trim or strip wallbox wires to the length indicated by the strip gauge on the back of the control
Push-in Terminals: Insert wires fully. NOTE: Push-in terminals are for use with
14 AWG (1.5 mm²) solid copper wire only. DO NOT use stranded or twisted wire.
OR
Screw Terminals: Tighten securely. Screw terminals are for use with
12 or 14 AWG (2.5 or 1.5 mm²) solid copper wire only. DO NOT use stranded or twisted wire.
9
Identify the circuit type.
9a - Single-Location control
One switch controlling the fan(s).
This switch will be a single-pole. The switch will have insulated wires connected to two screws of the same color plus a green ground screw.
12
Connect Control(s).
• For installations involving more than one control in a wallbox, refer to Multigang Installations before beginning.
• Only one Wall Control (MA-FQ4M) can be used with up to 2 Accessory Controls (MA-AFQ4).
12c - Three-Location control
One location will be replaced with a Wall Control (MA-FQ4M) and the other two with Accessory Controls
(MA-AFQ4).
Brass screws
Wall Control or
Accessory Control
Tagged wires
Black screw
Green wire
Ground
Replace the 4-way switch
Note: 4-way switch may be replaced with either a Wall
Control or an Accessory Control
• Connect both of the tagged wires removed from the
4-way switch to the black screw terminal on the
Control (one wire to the screw and the other to the push-in terminal).
• Connect one of the remaining wires removed from the switch to one of the brass screw terminals on the
Control.
• Connect the remaining wire removed from the switch to the remaining brass screw terminal on the Control.
• Use wire connectors to connect the green ground wire on the Control to the bare copper or green ground wire in the wallbox (see Important Note 3), and to cap any unused wires .
Replace the two 3-way switches
Follow Step 12b - Two-Location control.
6b - Flush Mount Bracket
• Do not install Canopy Module in ceiling.
• Attach Canopy Module to bracket with a cable tie.
• Ensure cable tie does not come in contact with moving motor parts.
• Install cable tie through notches on Canopy Module. Pull tight and clip excess.
To junction box
Notch
7
Attach canopy.
7a - Down Rod Bracket
• Check all wire connections.
• Tuck the wires into the junction box and/or canopy enclosure.
• Attach the canopy enclosure to the fan mounting bracket, taking care not to pinch any wires.
To junction box
7b - Flush Mount Bracket
• Check all wire connections.
• Tuck the wires into the junction box and/or bracket.
• Ensure wires and/or wire connectors do not come in contact with moving motor parts.
• Attach the canopy enclosure to the fan mounting bracket, taking care not to pinch any wires.
To junction box
Cable tie
Ground
(Bare Copper or
Green Wire)
9b - Two-Location control
Note: Screw placement may be different on your switch.
Ground
(Bare Copper or
Green Wire)
Different colored screw (Common)
Tagged wire
Two switches controlling the fan(s).
Both switches will be 3-way. Each switch will have insulated wires connected to three screws plus a green ground screw. One of these wires is connected to a screw of a different color (not green) or labeled COMMON.
this wire on both switches to identify when wiring.
TAG
12a - Single-Location control
Wall Control
Brass screws
Black screw
Green wire
Ground
Wiring the Wall Control (MA-FQ4M):
• Connect either of the wires removed from the switch to the black screw terminal on the Wall Control.
• Connect the remaining wire removed from the switch to one of the brass screw terminals on the Wall
Control.
• Tighten the remaining screw terminal on the
Wall Control. It is not used in a single-pole circuit.
• Use wire connectors to connect the ground wire on the Wall Control to the or green ground wire in the wallbox (see Important Note 3), and to cap any unused wires .
Reference Wiring Diagram
Wall Control or
Accessory Control
Wall Control or
Accessory Control
Live
120 V~
60 Hz
Br a s
Brass s
Black
Wallbox
Green
Ground
Brass
Brass
Black
Green
Ground
Wallbox
Wall Control or
Accessory Control
B r a s s
Brass
Black
Green
Ground
Wallbox
Canopy Module and Fan Fixture
Neutral
Canopy Module and Fan Fixture
Up to 4 Canopy
Modules and Fans
9c - Three-Location control
Note: Screw placement may be different on your switch.
Three switches controlling the fan(s).
Two switches will be 3-way and one will be a 4-way.
TAG the two 3-way switches as in the Two-Location diagram above. The 4-way switch will have insulated wires connected to four screws plus a green ground screw.
TAG two insulated wires which are connected to same colored screws.
Reference Wiring Diagram
Wall Control
Live
120 V~
60 Hz
Brass
Brass
Black
Wallbox
Green
Ground
Canopy Module and Fan Fixture
Neutral
Canopy Module and Fan Fixture
Up to 4 Canopy
Modules and Fans
13
Mount Control(s) to wallbox.
• Form wires carefully into the wallbox, mount and align the Control(s).
• Install wallplate(s).
Start screws.
Caution: Do not overtighten mounting screws.
Align control and tighten screws.
Same colored screw (or marked
IN or OUT)
Ground
(Bare Copper or
Green Wire)
Tagged wires
10
Identify switch wires.
Important Note:
Your wall switch may have two wires attached to the same screw (see illustrations below for examples). Tape these two wires together before disconnecting. When wiring, connect wires to new Controls the same way they were connected to the switch.
One wire in the push-in terminal and one to the screw.
One continuous wire to the screw.
12b - Two-Location control
One location will be replaced with a Wall Control (MA-FQ4M) and the other with an Accessory Control (MA-AFQ4).
Brass screws
Wall Control and
Accessory Control
Black screw
Green wire
Tag
Ground
Wiring the Wall Control and Accessory Control:
• Connect the tagged wire removed from the switch to the black screw terminal on the Control.
• Connect one of the remaining wires removed from the switch to one of the brass screw terminals on the
Control.
• Connect the remaining wire removed from the switch to the remaining brass screw terminal on the Control.
• Use wire connectors to connect the green ground wire on the Control to the bare copper or green ground wire in the wallbox (see Important Note 3), and to cap any unused wires .
14
Turn ON power.
• Do not turn on power until Wall Control, Accessory Control(s) and Canopy Module(s) have been installed and wired.
• Turn power ON at circuit breaker (or replace fuse).
Warning: Fan(s) will return to full speed when power is restored. Clean up any tools or ladders near the fan(s) first.
15
Activate system.
• Pull out the Front Accessible Service Switch ( FASS ) at the bottom of the Wall Control, wait 10 seconds, then push it back in.
• The LEDs will cycle for up to 30 seconds.
• If installing more than one Wall Control/Canopy Module system, activate one at a time with FASS pushed in on all other systems.
• Accessory Controls do not require activation.
11
Disconnect switch wires.
Reference Wiring Diagram
Wall Control or
Accessory Control
Wall Control or
Accessory Control
Screw Terminals:
Turn screws to loosen.
Push-in Terminals:
Insert screwdriver.
Pull wire out.
Looped Wire:
Turn screw to loosen.
Brass
Brass
Live
120 V~
60 Hz
Wallbox
Green
Ground
Brass
Brass
Black
Green
Ground
Wallbox
Canopy Module and Fan Fixture
Neutral
Canopy Module and Fan Fixture
Up to 4 Canopy
Modules and Fans
16
Recommended - Disconnect pull chains.
• Disconnect pull chain extensions to prevent fan speed from being adjusted at the fan(s).