MK300
[Applicable models]
Three phase 400V(0.75kW~3.7kW)
Foreward
Thank you for purchasing Panasonic products.
● For optimum performance and safety, please read this manual carefully before using this product.
● Please save this manual for future use.
Applicability of the Product
● This general-purpose inverter manufactured by us is not designed or manufactured to be used in machine or system in situations that can affect or endanger human life.
Before using this product in special applications such as machinery or systems in movable object, medical, aerospace, nuclear energy control, submarine relay equipments or systems, please contact us.
● Although this product was manufactured under strict quality control system, it is strongly recommended to install safety devices to prevent serious accidents when used in facilities where a breakdown of this product is likely to cause a serious injury or major losses.
● Do not use this product for loads other than a 3-phase induction motor.
● This product, if discarded, should be treated as industrial wastes.
Table of Contents
Table of Contents .............................................................................i
Safety Precautions......................................................................... 1
Points for Handling......................................................................... 7
Special Precautions ............................................................................8
1. Part Names and Functions .......................................................11
1.1 Part Names and Functions .........................................................12
1.2 List of Models..............................................................................14
2. Installation................................................................................ 15
2.1 Safety Precautions......................................................................16
2.2 Installation Precautions...............................................................17
2.3 Outline Dimensions.....................................................................19
3. Wiring....................................................................................... 21
3.1 Safety Precautions......................................................................22
3.2 Removal and Installation of Terminal Cover................................23
3.3 Wiring (Main Circuit) ...................................................................24
3.4 Wiring (Control Circuit)................................................................27
4. Operation Method (Basic & Trial Operations).......................... 33
4.1 Safety Precautions......................................................................34
4.2 Description of Operation Panel ...................................................35
4.3 Operation Modes ........................................................................36
4.4 Switching between Operation Modes .........................................37
4.5 Rotation Direction Setting Mode .................................................38
4.6 Monitoring Mode .........................................................................39 i
4.7 Method for Changing Parameters...............................................45
4.8 List of Function Parameters........................................................48
4.9 Operation Method .......................................................................65
4.10 Operating via Operation Panel..................................................66
4.11 Operating based on External Input Signal.................................69
4.12 Setting Frequency via External Device .....................................70
4.13 V/F Control Setting Method......................................................73
4.14 Auto-tuning................................................................................74
4.15 Vector Control ...........................................................................76
5. Troubleshooting ....................................................................... 79
5.1 Safety Precautions......................................................................80
5.2 Abnormality Diagnostic Function and Reset Method ..................80
5.3 Handling Abnormality..................................................................83
6. Maintenance and Inspection.................................................... 85
6.1 Safety Precautions......................................................................86
6.2 Precautions on Inspection...........................................................86
6.3 Inspection Items..........................................................................86
6.4 Component Replacement ...........................................................87
6.5 Maintenance and Inspection Table..............................................88
7. Specifications........................................................................... 91
7.1 Rated Specifications ...................................................................92
7.2 Standard Specifications...............................................................94
7.3 Common Specifications ..............................................................95
ii
Appendix Function Parameter List............................................... 99
“Administrative Measures on the Control of Pollutio n Caused by
Electronic Information Products” in China
Names and Content Marks of Toxic and Hazardous Substances or
Elements .................................................................................... 214
Applicable Standards ................................................................. 215
Warranty..................................................................................... 217
Revision History iii
iv
Safety Precautions
1
Safety Precautions
Safety Precautions
Please read this Manual and related documents carefully before attempting to install, operate, service or inspect the inverter.
Make sure that you have a full understanding of the device, the safety information and all precautions before starting the use.
Precautions described in this Manual are divided into two grades:
“Danger” and “Caution”.
Dange r
: Indicates dangerous situations that could lead to serious injury or death in case of any mishandling.
Caution
: Indicates dangerous situations that could lead to moderate or minor injury or property damage in case of any mishandling.
In addition, failure to follow the precautions in Caution may also lead to serious situations depending on conditions.
Since the precautions of the above two grades are of critical importance, please make sure to observe them strictly.
2
Safety Precautions
1. Installation
Caution
● Install the unit on non-flammable material, such as metal, etc. Failure to do so may lead to fire.
● Do not place the unit near flammable materials. Failure to do so may lead to fire.
● Do not hold the unit by terminal cover while transporting it. Failure to do so may cause the unit to drop and result in injury.
● Do not let foreign matters such as metal sheet enter into the unit. Failure to do so may lead to fire.
● Install the unit on a place strong enough to support the weight of it according to the instruction manual. Failure to do so may lead to dropping of the unit and thus result in injury.
● Do not install or operate an inverter that is damaged or with part(s) missing. Failure to do so may result in injury.
2. Wiring
Danger
● Always make sure that power is OFF before starting wiring. Failure to do so may result in electric shock or fire.
● Always connect ground wire. Failure to do so may result in electric shock or fire.
● Wiring work should always be carried out by a qualified electrician.
Failure to do so may result in electric shock or fire.
● Always install the unit before wiring. Failure to do so may result in electric shock or injury.
3
Safety Precautions
Caution
● Do not connect an AC power supply to output terminals (U·V·W). Failure to do so may result in injury or fire.
● Make sure that the voltage rating of the product matches with that of AC power supply. Or it may result in injury and fire.
● Tighten terminal screws to specified torque. Failure to do so may lead to fire.
● Do not connect any resistors to the DC terminals P/DB+ and N−. Failure to do so may lead to fire.
3. Operation
Danger
● Always close the terminal cover before turning ON the inlet power. Do not open the terminal cover while the power is ON. Failure to do so may result in electric shock or fire.
● Do not operate the switches or dials with wet hands. Failure to do so may result in electric shock.
● Do not touch the inverter terminals even when the inverter is stopped while the power is ON. Failure to do so may result in electric shock.
● The
STOP
button is not designed for emergency stop purposes. So set a separate button for emergency stop. Failure to do so may result in injury.
● Depending on the start mode and the settings of ride-through function, if operating signal is ON or the power is restored from a power failure, the inverter may start (or restart) suddenly. Keep away from the unit to avoid injury.
Design the machine so that it can ensure personal safety even if the 〔 inverter starts suddenly.
〕
● Depending on the setting of start mode function, when reset fault trip with the operating signal present, the inverter may restart suddenly.
Always take measures to ensure personal safety. Failure to do so may result in injury.
● When retry function is in use, the unit may automatically start (restart) suddenly, so do not approach the unit. (Always take measures to ensure personal safety.) Failure to do so may result in injury.
4
Safety Precautions
● While auto-tuning function is in use, the inverter will automatically drive the motor in the stand-along mode when the
RUN
button on the panel is pressed.
Always take measures to ensure personal safety. Failure to do so may result in injury.
● Please confirm and adjust parameters before operation.
Some machines are likely to trigger unexpected operations.
Always take measures to ensure personal safety. Failure to do so may result in injury.
● If data change during operation, variations of the motor and motor load may change drastically and sudden stop will occur.
Always take measures to ensure personal safety. Failure to do so may result in injury.
Caution
● The heat sinks and braking resistors are at high temperature, so do not touch them. Doing so may result in burns.
● The inverter can be easily switched from low speed to high speed, so confirm carefully the allowable range of the motor and machine before making setting. Failure to do so may result in injury.
● Set separate holding brakes if required. Failure to do so may result in injury.
4. Maintenance, Inspection and Part Replacement
Danger
● Wait at least five minutes after turning OFF the inlet power before starting maintenance and inspection. Failure to do so may result in electric shock.
● Maintenance, inspection and part replacement work must be done only by qualified persons.
[Remove all metal personal belongings (watches, bracelets, etc.) before starting work.]
Please use insulated tools. Failure to do so may result in electric shock or injury.
● Do not replace the cooling fan while the power is ON. Failure to do so may result in electric shock or injury.
5
Safety Precautions
Caution
● Employ an electrical engineering company to periodically tighten the terminal screws. Loosen screws may lead to overheating or fire.
5. Others
Danger
● Never modify the unit.
Failure to do so may result in injury.
6. General Precautions
All diagrams in this instruction manual show the state with the cover or safety partitions removed to explain the details. Be sure to replace the covers and partitions in position, and then operate the unit according to the instruction manual.
7. Warning Label on Inverter
6
Points for Handling
Special Precautions.................................................8
7
Notes for the Use of Inverter
Special Precautions
Use the inverter only within the allow able ambient temperature range (-10~
50 ).
Since the service life of the inverter is greatly affected by the ambient temperature, use it within the allowable temperature range. Also, observe the installation directions and conditions. (Refer to P.17)
The inverter will be damaged if the power voltage is applied to its output side.
Applying power voltage to the output terminal U, V or W will damage the inverter.
Check carefully for faulty wiring and operation sequence (commercial switching circuit, etc.). Never apply a voltage exceeding the allowable range.
Never touch the inside of the inverter during operation.
It could be extremely dangerous since the inverter contains high-voltage circuit. Be sure to turn OFF the power of the inverter and wait at least 5 minutes before making an internal check. Do not touch the heat sink or the braking resistor during operation as these parts are at high temperature.
Radio interference
The main circuit of the inverter contains a high-frequency harmonic component and may interfere with communicating equipment s (such as AM radio) near by. The severity of inte rference depends on the radio fi eld strength a nd is hard to be eliminated completely. While it ma y be reduced by relocating radio antenna, using noise filter, housing the inverter in a metal box, or routing cables in conduit. (Please inquire separately.)
Do not conduct insulation resistance test between wires of the inverter.
To measure insulation resist ance between power cord and motor wires, please remove the cables connected to the invert er and conduct test w ith them. Do not conduct insulation test on the control circ uits. However, insulation test can b e performed between charging unit and the ground.
Do not use a ma gnetic contactor which is connected to the po wer side or load side of the inverter to start or stop the motor (inverter).
Frequent ON/OFF switching on the power supply side can cause inverter malfunction. Also, do not conduct ON/OFF switching on the load side during inverter operation, or it can cause fault trip of the inverter. Start or stop the motor by operating signals of the inverter only.
Do not connect a power capacitor or a surge absorber to the output side of the inverter.
Such device can damage the inverter, resulting in breakage of capacitors and other parts. Remove it if connected.
Do not use the inverter for load other than a motor or for a 1-phase motor.
8
Notes for the U se of Inverter
Precautions for inverter’s protection function
The inverter integrates various protection functions such as stall prevention, current limiting and over-current shut-off. These protection functions are designed to protect the inverter against the sudden abnormal conditions, instead of general control functions.
Therefore, avoid using them in applications where they will be activated under normal conditions.
Failure to do so may shorten the inverter's service life or damage the inverter.
Always measure the output current, etc. with a meter, check the details of the fault trip memory, and confirm that operation conditions conform to the precautions and specifications are correct.
In case the protection function is enabled, reset and restart the inverter only after all faults had been removed.
Besides, if the breaker on the input side of the inverter trips, it may be due to the wiring errors or the damaged parts in the inverter.
Find out the breaker tripping causes, and reconnect the breaker after all faults had been removed.
Take the measure of suppressing higher order harmonics.
The higher order harmonics generated by the inverter may result in over-heating or damage of the intake phase capacitor or the electric generator.
Precautions for motors of 400V series
If the inverter is used to drive the motors of 400V series, in this case, use the motors that had undergone a reinforced insulation treatment or adopt a method of suppressing the surge voltage.
The surge voltage on the motor terminal produced due to the wiring parameters may lead to the aging of insulation of the motor for such reason.
The electronic thermal relay may be unable to provide an overheating protection for motors. It is therefore s uggested to also set an external thermal relay or a PTC thermistor to provide the overheating protection.
9
Notes for the Use of Inverter
10
1
Part Names and Functions
1.1 Part Names and Functions..............................12
1.2 List of Models ..................................................14
11
2
7
6
1. Part Names and Functions
1.1 Part Names and Functions
1
3
AT
AK
AM
4
AM
8
9
5
AM
AL
AM
12
1. Part Names and Functions
① Operation panel unit
② Warning label
③ Casing
④ ※
⑤ Heat sink
⑥ Inlet hole for main circuit wire
⑦ Inlet hole for control wire
⑧ Connection terminals for optional units (RJ45)
⑨ Terminal Block for control cir input/output) cuit (signal
⑩ Terminal Block for control circuit (relay output)
⑪ Terminal block for main circuit
⑫ Ground terminal
⑬ Mounting holes
⑭ Terminal cover
⑮ Connection cover for optional units
⑯ Fix screws for terminal covers
⑰ Terminal cover for main circuit
⑱ Cooling fan connector cover ( 2)
⑲ Cooling fan( 2)
⑳ Cooling fan cover( 2)
※ 1 Check that the rating nameplate confirms to your order.
※ 2 Cooling fans are not provided for models with a capacity of 0.75kW or lower.
(⑱and ⑳ shall be equipped.)
13
1. Part Names and Functions
1.2 List of models
Series
Power supply
3-phase
400V
Appli cap cable m otor acity (k W)
0.75
1.5
2.2
3.7
Voltage Class
4: 3-phase 400V
Applicable motor capacity
Model No.
AMK3000P74
AMK3001P54
AMK3002P24
AMK3003P74
14
2
Installation
2.1 Safety Precautions ..........................................16
2.2 Installation Precautions ...................................17
2.3 Outline Dimensions .........................................19
15
2. Installation
2.1 Safety Precautions
Install the unit on non-flammable material, such as metal, etc.
Failure to do so may lead to fire.
Do not place the unit near flammable materials
Failure to do so may lead to fire.
Do not hold the unit by terminal cover while transporting it.
Failure to do so may cause the unit to drop and result in injury.
Do not let foreign matter such as metal sheet enter into the unit.
Failure to do so may lead to fire.
Install the unit on a place strong enough to support the weight of it according to the instruction manual.
Failure to do so may lead to dropping of the unit and thus result in injury
Do not inst all or operate an inv erter that is da maged or with part(s) missing.
Failure to do so may result in injury.
16
2. Installation
2.2 Installation Precautions
■ Do not install the inverter in the following locations.
· Locations subject to direct sunlight.
· Locations subject to water vapor or high humidity.
· Locations with large amount of oil mist, dust or fiber dust.
· Locations where rain water, water drops or oil drops may come in contact.
· Locations where there are corrosive gases, explosive gases or flammable gases.
· Installation onto flammable materials such as wood, or near flammable materials.
· Locations subject to vibration.
■ Make sure that the ambient temperature stays within the specified range.
If the inverter is installed near a heat generating device or housed in a p anel, its surrounding temperature will increase. This may shorten the life of the inverter .
When housing t he inverter in a panel, give sufficient consideration to the cooling method and the panel size.
○ Allowable ambient temperature range: -10 to +50℃
(Ambient temperature should be measured at a point 5 cm from the inverter.)
○ In case multiple inverters are installed
If multiple inverters are installed sideways, ambient temperature should be within the range of -10 to + 40 °C.
■ Install the inverter vertically
Installing the inv erter in an y other way will decrease heat dissip ation effect and result in malfunction.
Vertical Horizontal Sideways
17
2. Installation
■
Space for Installation
When a single inverter is installed
To ensure that there are suf ficient spaces for the ventilatio n (cooling) and wiring of the in verter, always provide a clearance as shown in the following figure.
5 cm
以上
10 cm 以上
5 cm
以上
10 cm 以上
When multiple inverters are installed sideways
If multiple inverters are inst alled sideways inside the control panel, always provide a clearance as show in the following figure.
5 cm
以上
5cm or
5 cm
以上
18
2.3 Outline Dimensions
2. Installation
● 3-phase 400V input type
Inverter capacity
0.75, 1.5 kW
2.2, 3.7 kW
W1
100
130
Note 1): Install the M4 screws in the mounting holes.
W
110
140
H1
130
130
H
140
140
D
156
156
Unit: mm
Φ d
5
5
19
2. Installation
20
3
Wiring
3.1 Safety Precautions·········································· 22
3.2 Removal and Installation of Terminal Cover···· 23
3.3 Wiring (Main Circuit) ······································· 24
3.4 Wiring (Control Circuit)···································· 27
21
3. Wiring
3.1 Safety Precautions
Make sure that Power is turned OFF before starting wiring.
Failure to do so may result in electric shock or fire.
Always connect ground wire.
Failure to do so may result in electric shock or fire.
Wiring work should always be carried out by qualified electricians.
Failure to do so may result in electric shock or fire.
Always install the unit before wiring.
Failure to do so may result in electric shock or injury.
Do not connect an AC power source to the output terminals (U·V·W).
Failure to do so may result in injury or fire.
Make sure that the voltage rating of the product matches with that of
AC power source.
Failure to do so may result in injury or fire.
Tighten the terminal screws to the specified tightening torque.
Failure to do so may lead to fire.
Do not connect resistors to the DC terminals P/DB+ or N−. Failure to do so may lead to fire.
22
3. Wiring
3.2 Removal and Installation of Terminal Cover
■ Removal and Installation of Terminal Cover
〔 Removal〕 ① Loosen the retaining screws in the terminal cover first, then pull it up lightly while holding the center button edge of the terminal cover.
〔 Installation〕②Insert the mounting jaw of the terminal cover into the slot on the casing, then lightly press down the center bottom edge of the terminal cover.
Note: the screws are designed to be unable to detach from the cover for the purpose of preventing dust from entering.
■ Removal and Installation of Terminal Cover of the Main Circuit
〔 Removal〕 ① While holding the center part of the terminal cover of the main circuit, pull it up lightly until the mounting jaw releases.
〔 Installation〕② Insert the mounting jaw of the terminal cover of the main circuit into the slot on the casing, then lightly press down the terminal cover.
Note: after installation, make sure that the terminal cover and the main circuit terminal cover are fitted in position.
23
3. Wiring
3.3 Wiring (Main Circuit)
3.3.1 Main Circuit Wiring Diagram
■ 3-phase 400V 0.75~3.7kW
To meet the CE marking requirements, protective devices against over-current, short-circuit and current leakage must be set up on the power supply side of the inverter.
配线用断路器
(MCCB) CCB)
■ Functions of Terminals for Main Circuit
Terminal No. Terminal Name
R/L1, S/L2, T/L3 Power supply for main circuit
U, V, W Inverter Output
P/DB+, DB-
N-
Braking resistor connection
Internal DC voltage
(negative)
×2
Ground
Explanation of terminal function
Connect to commercial power.
Connect to 3-phase motor.
Connect to breaking resistor.
Negative terminal of the internal DC voltage.
Ground terminal.
3-phase 400 V type: ground resistance 10 Ω or less. Ground the neutral of the power source.
24
3. Wiring
3.3.2 Precautions on Wiring Main Circuit
■ Precautions on Wiring
To avoid mistakes in wiring and operation, be sure to observe the following guides. (Failure to do so may damage the unit.)
· Always connect the power source to input terminals (R/L1, S/L2, T/L3), and connect the motor to output terminals (U, V, W). Please connect the output terminals (U, V, W) in the correct sequence. Failure to do so may cause the motor to run in the reverse direction.
· Use round crimp terminals with sleeve for power source and motor connections. Select crimp terminals according to wire sizes and screw sizes.
· After wiring main circuit, confirm the tightening condition of terminals.
· Main circuit must be wired prior to control circuit. Otherwise, re-tightening operation is not possible after control circuit wiring is completed.
· When connecting directly to a transformer of large capacity (500 kVA or more), always install an AC reactor on the input side of the inverter.
Note 1: It is recommended to use teflon insulated wire (600 V, Class 2, allowable operating temperature up to 75 °C) for main circuit wiring.
Note 2: Use wires with larger diameter if the wiring distance is long.
Note 3: If the over-current trip of the circuit breaker is a magnetic type, the device could become overheated due to higher harmonics. Use a load rate of 50% or lower in this case.
Note 4: Use a circuit breaker for the motor.
Note 5: Always connect protective devices against over-current, short-circuit and current leakage on the input side.
■ Precautions on Using Regenerative Brakes
· When using regenerative brakes, set the parameter P026 to "0". Since its factory setting is "1", the brakes will not be activated in that case.
· Specifications for regenerative brakes are shown as follows. Carefully consider the operation conditions before using them. Note that the inverter could be damaged if a brake outside specifications is used.
25
3. Wiring
■ Connected Device, Wire Size and Tightening Torque (3-phase 400V)
Inverter capacity
Current rating of circuit breaker for wiring (MCCB)
Wire size
R/L1, S/L2,
T/L3,
U, V, W
Ground wire
Screw size
Braking resistor*1
Tightening torque
Allowable braking utilization rate
Resistance
Allowable continuous value power rating
0.75 kW
1.5 kW
10 A
15 A
2 mm 2
2 mm 2
(AWG14)
5% 470Ω 80W
5% 470Ω 80W
2.2 kW 20 A
(AWG14)
3.5 mm 2 5% 320Ω 120W
3.7 kW 30 A (AWG12) 5% 190Ω 220W
*1) The above specifications are reference data in such conditions where the braking torque is 100%, the max. operating time is 5s and the max. braking utilization rate is 5%.
Notes for Customers when selecting a braking resistor
1) Resistance Value (Ω)
When selecting a resistor by referring to the resistance value as shown in the above table, a larger resistance value can by chosen, however, the braking torque shall be decreased accordingly.
2) Allowable continuous power rating (W)
A larger power rating may be chosen when referring to the value as shown in the above table, yet in this case, it will cause the resistor to produce lots of heat (300℃).
Please cooperate with the resistor manufacturer to take precautions during installation.
3) Allowable braking utilization rate (%)
The larger the continuous power rating of the braking resistor, the higher the utilization rate can be used in the theoretical calculation. Yet in this case, the resistor in the inverter shall be over-heated, therefore, it is suggested to use the utilization rate of 5% as specified.
T0
运
行
频
率
T1
1) Braking torque: 100% or more
2) Max. Operating Time: T1max= 5s
3) Max. Utilization Rate: T1/T0 (%ED) 5%
26
3. Wiring
3.4 Wiring (Control Circuit)
3.4.1 Terminal Arrangement and Functions
■ Terminal Arrangement
(com)
Analog output
(0~10V)
RS485 communication terminals
(com)
Open-collector output
(TR1, TR2)
Relay output
· Specification for frequency setting potentiometer (VR) : 10kΩ, 1/4W or higher
· Specification for relay output contact: 1c volt free contact
230V AC 0.25 A (resistive load), 30V DC 1A (resistive load)
· Specification for open-coll ector output: Max. rating 50V DC, 50mA
27
3. Wiring
■ Explanation of terminals for control circuit
Terminal No.
①
②
③
④
⑤
⑥
⑦
Terminal Function
Input terminal for multi-function control signal SW1
Input terminal for multi-function control signal SW2
Input terminal for multi-function control signal SW3
Input terminal for multi-function control signal SW4
Input terminal for multi-function control signal SW5
Input terminal for multi-function control signal SW6
Common terminals for input signals (①~⑥)
Output terminal for open-collector (TR1) (C1: Collector) ⑧
⑨
⑩
⑪
Output terminal for open-collector (TR2) (C2: Collector)
Common output terminal for open-collector (E: Emitter)
Connection terminal for frequency setting potentiometer (+5 V)
⑱
A
B
⑫
⑬
⑭
⑮
⑯
⑰
Input terminal for analog signal of frequency setting
Input terminal for the 2 nd analog signal
Common terminals for analog signals (⑪, ⑫, ⑬, ⑮)
Output terminals for analog signals (0~10V)
+ terminal for RS485 communication transmission line (D+)
- terminal for RS485 communication transmission line (D-)
Terminal for terminal station of RS485 communication (E)
Output terminal for relay contact (NO: factory setting)
Output terminal for relay contact (NC: factory setting)
C Output terminal for relay contact (COM)
Note: common terminals (⑦, ⑩, ⑭) are connected internally. Do not ground the common terminal.
28
3. Wiring
3.4.2
Common Precautions on Terminals for Control Circuit
■ Precautions on Wiring
· For wiring of terminals of control circuit, strip specified length of insulation coating before connecting.
· Loosen the terminal screws and insert the wires from the bottom of the terminal block, and tighten the screws to specified tightening torque.
· Any loose connection could cause wire to come off and lead to malfunction. Also, over-tightening could cause short-circuit due to the broken screws and unit, thus lead to malfunction
· Use shielded cables for all control signal lines and separate them from power lines or high-voltage circuits (20 cm or more).
· Wiring length of control signal lines should be within 30m.
· Since input signals of control circuit are feeble, use dedicated terminals for feeble signals to avoid poor contact during contact input.
■ Wire Size and Tightening Torque for Control Circuit Terminal
Terminal symbol
Screw size
Tightening torque
N·m
Wire size
Stripping length of wire
A,B,C M3 0.5~0.6
① to ⑱ M2 0.22~0.25
0.25~0.75mm
2
(AWG24~AWG18)
0.25~0.75mm
2
(AWG24~AWG18)
6mm
5mm
· Screwdriver: Small-size ㊀ screwdriver
· Stripping length of wire
(Thickness of the edge: 0.4mm/Width of the edge: 2.5mm)
· Terminal block for main circuit:
The maximum number of the conductors: 2*1
· Terminal block for control circuit (Relay output):
· Terminal block for control circuit (Signal input/output):
The maximum number of the conductors: 2 *1
*1 The maximum number of the conductors should be made in the reach of the suitable electric wire size.
■ Notes for wiring
To prevent wire disconnection, please observe the following points:
· Do not damage the core wire when peeling off its insulation layer.
· Connect the core wires at the same time.
· Do not lift the core wire to make a connection through welding. A disconnection is possible in this case due to vibration.
· After wiring, do not apply voltage to the cables.
· In respect of the terminal structure, if the wire is tightened in an anti-clockwise direction, it is an error connection.
Unplug the wire and reconnect it after the correct terminal had been confirmed.
请将电缆线
插在此处
29
3. Wiring
3.4.3 Specific Precautions on Each Terminal
■ Input Terminal for Multi-function Control Signal (Terminals No. ① to ⑥)
· General SINK/SOURCE input type. The external input devices, SINK input or SOURCE input type, can be applicable. Please carry out the wiring as the wiring example given below.
■ Wiring Diagram and Precautions for SINK Input Setting
· Input open-collector signal or volt-free contact signal in between the input terminal (①~⑥) and the 0V-COM terminal ⑦.
· Never supply (+) voltage from an external power source or use an external pull-up resistor. Otherwise, it will cause malfunction.
· Note that the 0V-COM terminal ⑦ is internally connected with the terminal
(⑩, ⑭) and the internal circuit 0V. Moreover, never ground it.
· Each terminal has a max. SINK current of 8mA.
4.7k
+5V
Max. SINK current: 8mA
Terminal ①
SW1
Internal Circuit of MK300 Inverter
0V
4.7k
+5V
0V
Max. SINK current: 8mA
Terminal ⑥
SW6
Terminal ⑦
0V-COM
0V
SW1~6 COM Terminal
External +V
Never use an external pull-up resistor.
SW□ SW1~6
Open-collector or volt-free contact
30
3. Wiring
■ Wiring Diagram and Precautions for SOURCE Input Setting
· Input open-collector signal or volt-free contact signal to the input terminal
(①~⑥) by supplying an external 24V power source. Connect the negative terminal (on the 0V side) of the external 24V power source to the 0V-COM terminal ⑦.
· Never use an external Pull-down resistor. Otherwise, it will cause malfunction.
· Note that the 0V-COM terminal ⑦ is internally connected to the terminal (⑩,
⑭ ) and the internal circuit 0V. Moreover, never ground it.
· Each terminal has a max. SOURCE current of 8mA.
Internal Circuit of MK300 Inverter
4.7k
+5V
Max. SOURCE current: 8mA
Terminal ①
SW1
0V
4.7k
+5V
0V
Terminal ⑥
SW6
Max. SOURCE current: 8mA
Terminal
⑦
0V-COM
0V
24V DC
SW1~6 COM Terminal
Never use an external Pull-down resistor.
0V
SW□
SW1~6
Open-collector or volt-free contact
31
3. Wiring
■ Wiring for Open-collector Output Terminals (Terminal No. ⑧ to ⑩)
· When using open-collector output terminals to drive inductive loads, always connect a freewheel diode.
■ Wiring for RS485 Communication Terminals (Terminal No. ⑯ to ⑱)
The following figure shows the terminals used when connection is made between PC and PLC via RS485 communication lines.
· As for communication cable, use a shielded twisted-pair cable and separate it from power lines or high-voltage circuits (20 cm or more).
· The total wiring length of the communication cables must not exceed 500m.
· Jump out the terminal “D-” and “E” of the inverter used as terminal station.
Jumping is not allowed for any other device.
32
4
Operation Method
(Basic & Trial Operations)
4.1 Safety Precautions...................................................... 34
4.2 Description of Operation Panel................................... 35
4.3 Operation Modes ........................................................ 36
4.4 Switching between Operation Modes ......................... 37
4.5 Rotation Direction Setting Mode ................................. 38
4.6 Monitoring Mode......................................................... 39
4.7 Method for Changing Parameters............................... 45
4.8 List of Function Parameters........................................ 48
4.9 Operation Method ....................................................... 65
4.10 Operating via Operation Panel ................................. 66
4.11 Operating based on External Input Signal ................ 69
4.12 Setting Frequency via External Device ..................... 70
4.13 V/F Control Setting Method ..................................... 73
4.14 Auto-tuning ............................................................... 74
4.15 Vector Control........................................................... 76
33
4. Operation Method (Basic & Trial Operations)
4.1 Safety Precautions
Always close the terminal cover before turning ON the inlet power.
Do not open the terminal cover while the power is ON. Failure to do so may result in electric shock or fire.
Do not operate the switches or dials with wet hands. Failure to do so may result in electric shock.
Do not touch the inverter terminals even when the inverter is stopped while the power is ON. Failure to do so may result in electric shock.
The
STOP
button is not designed for emergency stop purposes.
Set a separate button for emergency stop. Failure to do so may result in injury.
The heat sinks and braking resistors are at high temperature, so do not touch them. Doing so may result in burns.
The inverter can be easily switched from low speed to high speed, so confirm carefully the allowable range of the motor and machine before making settings. Failure to do so may result in injury.
Set separate holding brakes if required. Failure to do so may result in injury.
Before turning on the power, check the following points again.
1. Check again whether all wirings are correct.
The reversed wirings between the power supply and the loads in particular could damage the inverter.
2. Check whether the voltage rating of the inverter matches with that of the power supply.
3. Check whether a phase-lead capacitor is connected to the motor.
The connection of a phase-lead capacitor may result in faults to the inverter and capacitor.
4. Confirm the set frequency before starting a trial operation.
34
4. Operation Method (Basic & Trial Operations)
4.2 Description of Operation Panel
①
②
③
⑧
⑩
⑨
No Component name
Symbols used in this Manual
① Display
②
FWD indicator
(green)
③
REV indicator
(green)
④
⑤
ALM indicator
(red)
PROG indicator
(green)
⑥ RUN
⑦ STOP button
⑧ MODE
RUN
STOP
MODE
⑨ ESC
ESC
To the right
⑩ Knob
To the left
Press down
④
⑤
⑥
⑦
Details of function
For displaying output frequency, current, linear speed, set frequency, communication station No., error details, each mode indication and function setting data.
For indicating forward run (ON during constant-speed running/Flickering during acceleration/deceleration running).
For indicating reverse run (ON during constant-speed running/Flickering during acceleration/deceleration running).
For indicating abnormality and alarms.
ON when switching the parameter setting mode.
A button for enabling the inverter to run.
A button for disabling the inverter to run.
A button used to switch modes of “operation status display” and “function setting”, and from data display to mode display.
Return to the previous action during parameters setting.
For adding the parameter No., increasing the set value and switching the direction setting.
For reducing the parameter No., decreasing the set value and switching the direction setting.
For pressing down when the mode, rotation direction, parameter No., or the set value had been confirmed.
And for switching between the frequency and current display in the mode of “operation status display”.
35
4. Operation Method (Basic & Trial Operations)
4.3 Operation Modes
Mode
Operation status display mode
Description
For displaying the output frequency and the output current
Frequency setting mode
Rotation direction setting mode
For digital setting of frequency and frequency command monitoring
For rotation direction setting of panel operation and control status (operation panel/external control/communication) monitoring
Control status monitoring mode
For monitoring of control status and abnormality
Parameter (P0) setting mode
Parameter (P1) setting mode
Parameter (P2) setting mode
Parameter (P3) setting mode
For changing and monitoring the parameter data, and using the copy function of parameter data.
For changing and monitoring the parameter data, and using the copy function of parameter data.
For changing and monitoring the parameter data, and using the copy function of parameter data.
For changing and monitoring the parameter data, and using the copy function of parameter data.
Panel Display Content
36
4. Operation Method (Basic & Trial Operations)
4.4 Switching between Operation Modes
· Press the
MODE button to switch between the modes of “operation status display” and “parameter setting”.
(The PROG LED will be turned ON in the parameter seeting mode.)
· In each mode, if the “Knob” button is pressed, the data monitoring or changing function will be enabled; and if the ESC button is pressed, it will return to the previous display status. Therefore, if the “Knob” button is pressed by mistake, just press the ESC button to return to the previous display status.
37
4. Operation Method (Basic & Trial Operations)
4.5 Rotation Direction Setting Mode
In the Operation Status Display mode, press the
MODE button once, the mode shall be changed to the Parameter Setting mode, then clockwisely rotate the panel Knob to select the Rotation Direction Setting mode and press the panel
Knob to display the rotation direction data, next, change the rotation direction with the Knob and press the the Knob to apply the change. (The factory setting is “Forward Run”.)
Finally, press the
RUN button to start the operation.
Operation
Command
Operation panel
External control
Display
L
E
Communication C
Rotation
Direction
Forward
Run
Reverse
Run
Display
F r
· The rotation direction setting in this mode is only enabled when P003 is set to 0.
The setting function is disabled and only the monitoring function is enabled when
P003 is set to 1.
38
4. Operation Method (Basic & Trial Operations)
No n001 n002 n003 n004 n005 n006 n007
4.6 Monitoring Mode
The Monitoring mode in the Setting mode enables you to view the inverter information.
27 items can be viewed in the Monitoring mode.
4.6.1 List of Monitoring Parameters n009 n010 n011 n012 n013 n015 n016 n017 n018 n019 n021 n022 n023 n024 n025 n026 n027
Name
Output frequency
Output current
Output voltage
Internal DC voltage
Set frequency
Communication station No. -
Operation times of timer Times
-
Control circuit terminal status
(input signal)
Control circuit terminal status
(output signal)
PID setting value (SP)
PID measured value (PV)
PID output value (MV)
-
-
Cumulative operation time of fan
Abnormality display 1 (latest)
Abnormality display 2
(second to latest)
Abnormality display 3
(third to latest)
Abnormality display 4
(fourth to latest)
-
-
-
-
Pulse input signal detection value
Winding length
Used for manufacturer’s confirmation
Used for manufacturer’s confirmation
Hz m
-
-
%
%
%
-
-
-
Analog input 1 %
Unit
Hz
A
VAC
VDC
Hz
Analog input 2
Temperature of internal module
%
℃
Content
To display the output frequency (unit: 0.1Hz)
To displaythe output current (unit: 0.1A)
To display the output voltage (unit: 1VAC )
To display the internal DC voltage (unit: 1VDC)
To display the set frequency (unit: 0.1Hz)
To display the current setting of the connmunication station
No.
To display the continuous operation times of timer in one cycle
To display the indication of the LED alarm
To display the input signal status of the control circuit terminal
To display the output signal status of the control circuit terminal
To display the setting value (SP) of PID control
To display the measured value (PV) of PID control
To display the output value (MV) of PID control
To show the cumulative operation time of the inverter
To show the cumulative operation time of fan of the inverter
To display the details of the latest abnormality
To display the details of abnormality from second to latest
To display the details of abnormality from third to latest
To display the details of abnormality from fourth to latest
To show the firmware version of the Unit
To display the detected frequency value based on the pulse input signal
To display the current winding length
-
-
To display the corresponding percentage of the analog quantity of the analog input terminal ⑫
To display the corresponding percentage of the analog quantity of the analog input terminal⑬
To show the temperature of the internal module.
39
4. Operation Method (Basic & Trial Operations)
4.6.2 Explanation of the Monitored Items n001
Output Frequency
To display the output frequency of the inverter; “0.0”shall be displayed if the inverter is in the stop status (unit: Hz). n002 n003 n004
Output Current
Output Voltage
Internal DC Voltage
To display the output frequency, output voltage as well as the internal DC voltage of the inverter. These indicated data are not served as values from precision measurement, they are provided for reference only. (if you need accurate values, use other measuring instruments.) n005
Set Frequency
To display the set frequency of the inverter (Unit: Hz). n006
Communication Station No.
To display the communication station number that had been set.
The communication station number can be set with “P132: Communication
Station No. Setting”. n007
Operation Times of Timer
To disply the operation times of the timer in one cycle in the sate of multi-step speed operation or acceleration/deceleration linking operation. When a cycle starts, the operation times shall be counted up. Yet when each operation ends and the next operation command is input, the counted times shall be cleared.
Operation times of timer can be set with “P324: Timer Operation Times”.
40
4. Operation Method (Basic & Trial Operations) n008
Alarm Type
To display different alarm LED contents.
Alarm Type Indication
Normal
Abnormal output voltage alarm
Overload alarm
Abnormal temperature alarm
Abnormal cooling fan alarm
Timer stop signal
Note: 1. When “Alarm LED Operation Selection”(Parameter P056) is set to “1”;
If all alarms occur simultaneously, their display priortity shall be as follows. (If a higher-priority alarm is in an active state, it will be continuously displayed even if a lower-priority alarm enters.)
Abnormal temperature alarm
>
Overload alarm
>
Abnormal output voltage alarm
>
Abnormal cooling fan alarm
>
Timer stop signal
41
4. Operation Method (Basic & Trial Operations) n009 n010
Control Circuit Terminal Status (Input Signal)
Control Circuit Terminal Status (Output Signal)
Monitoring Parameters n009 and n010 and displaying the statuses of the input and output signals of the control circuit terminal.
Segment a1 to f1 shall accordingly light up or light out when the input terminals
(①~⑥) and the common terminal ⑦ are turned ON or turn OFF. When output terminals are closed (ON) between ⑧ to ⑩ and ⑨ to ⑩, segment a1 and b1 of n010 light up; when output terminals are opened (OFF) between ⑧ to ⑩ and
⑨ to ⑩, segment a1 and b1 light out.
Segment c1 lights up when the output terminals is ON (Excitation in ON status: short circuit across A-C; non-excitation in ON status: short circuit across B-C); segment c1 lights out when the output terminal is OFF (Excitation in ON status: open circuit across B-C; non-excitation in ON status: open circuit across A-C).)
Monitor No. n009 n010
I/O signal
SW1
SW2
SW3
SW4
SW5
SW6
Open-collector 1
Open-collector 2
Relay
Terminal indication
“a” lights up
“b” lights up
LED segment indication
Signal ON Signal OFF
“a1” lights up “a1” lights out
“b1” lights up “b1” lights out
“c” lights up
“d” lights up
“c1” lights up
“d1” lights up
“c1” lights out
“d1” lights out
“e” lights up
“f” lights up
“a” lights up
“b” lights up
“c” lights up
“e1” lights up
“f1” lights up
“e1” lights out
“f1” lights out
“a1” lights up “a1” lights out
“b1” lights up “b1” lights out
“c1” lights up “c1” lights out l l
j j i f f
42
4. Operation Method (Basic & Trial Operations) n011 n012 n013
PID Setting Value (SP)
PID Measured Value (PV)
PID Output Value (MV)
To display the setting value (SP), measured value (PV) as well as the output value (MV) of PID control (Unit: %). n014
Cumulative Operation Time
n015 n016
Cumulative Operation Time of Fan
“n014” shows the accumulative power-on time of inverter. “n015” shows the accumulative operation time of the inverter cooling fan. “P052: Cooling Fan
ON-OFF Control” is set to “1”: In synchronized operation, no counting will be executed when the cooling fan is stopped.
The basic display unit is “0.001” corresponding to 1 hour. The display increment is
“0.01” corresponding to 10 hours for the time longer than 10.0; and “0.1” corresponding to 100 hours for the time longer than 100.0; and “1” corresponding to
1000 hours for the time longer than 1000.0.
Since there are errors in the displayed values, so just use them for reference only.
Abnormality Display 1 (Latest)
n017
Abnormality Display 2 (Second to Latest)
n018 n019
Abnormality Display 3 (Third to Latest)
Abnormality Display 1 (Fourth to Latest)
To show the abnormality information of the inverter (latest, second to latest, third to latest and fourth to latest). n020
Unit Version
· To show the firmware versions of the MK300 unit and the operation panel.
· The model code and version code are shown as follows.
About the version of the MK300 unit
· Operation status display varies depending on the combination of the firmware versions of MK300 unit and the operation panel.
43
4. Operation Method (Basic & Trial Operations) n021 Pulse Input Signal Detection Value
· To show the detected frequency value based on the pulse input signal from the inverter (unit: Hz). n022
Winding Length
· To show the calculated result of the winding length of the pulse input signal when any one of the set values of “P101: SW1 Function Selection ” to“P106:
SW6 Function Selection” is set to “14”.
· The winding length is calculated as below.
Winding Length=
(Pulse value input to SW)×(P343:Winding length ratio)
1000
· The relationship between the winding length and the indication is as follows.
Display 1~9999 when the winding length is 1m~9,999m.
Display1.000~9.999 when the winding length is 10,000m~99,999m.
Display 10.00~60.00 when the winding length is 100,000m~600,000m.
· The calculated value shall be cleared when any one of the set values of
“P101: SW1 Function Selection ” to“P106: SW6 Function Selection” is set to
“15”and SW is turned to be ON. n025
Analog Input 1
To show the corresponding percentage (0~100%) of the analog quantity of the analog input terminal ⑫ (unit: %). n026
Analog Input 2
To show the corresponding percentage (0~100%) of the analog quantity of the analog input terminal ⑬ (unit: %). n027
Temperature of Internal Module
To show the temperature of the internal module (unit: ℃).
44
4. Operation Method (Basic & Trial Operations)
4.7 Method for Changing Parameters
Be sure to change and set various function parameters in stop status. And note that some function parameters can be changed during operation.
4.7.1 Changing Function Parameters in Stop Status
Setting Example:
Change the base frequency from 50.0Hz to 45.0Hz (that is, change the setting value of parameter P013 from “50.0” to “45.0”)
①
Press
STOP
button to stop the inverter and show
“0000”.
STOP
② Press
MODE
button to show “Fr”. MODE
③ Rotate the encoder to “P0--”.
④ Press the encoder to show “P001”.
⑤ Rotate the encoder to “P013”.
⑥ Press the encoder to show “50.0” and it flickers.
⑦ Rotate the encoder to “45.0”, and it flickers.
⑧ Press the encoder to set the data. It shows “P014”.
⑨
Press
MODE button to show “0000”.
By now, the inverter is in the normal stop status and can be operated.
MODE
45
4. Operation Method (Basic & Trial Operations)
4.7.2 Changing Function Parameters During Operation
Changing parameters during operation are likely to cause great changes to the motor and motor load, thus resulting in a sudden stop of them.
(Please take measures to ensure personal safety.) Failure to do so may result in injury.
For the function parameters that can be changed during operation, please refer to items marked with “○” in “Changeable during Operation” of “4.8 List of
Function Parameters”.
Setting Example:
Change the first deceleration time from 5.0s to 10.0s (that is, change the setting value of parameter P002 from “5.0” to “10.0”). Confirm
Use the current data to control the motor
①
Confirm the operation status (operating at
50.0Hz ).
② Press
MODE
button to show “Fr”. MODE
③ Rotate the encoder to “P0--”.
④ Press the encoder to show “P001”.
⑤ Rotate the encoder to “P002”.
⑥ Press the encoder to show “5.0” and it flickers.
⑦ Press the encoder to show “10.0” and it flickers.
Use new data to control the motor
① Press the encoder to set the data. It shows “P002”.
② Press
MODE
button to show “50.0”. MODE
46
4. Operation Method (Basic & Trial Operations)
• The initial values of such parameters may vary with the different ratings of inverters.
• If you monitor parameters that cannot be set during operation when the operation signal is OFF, the setting values will flicker and then become changeable.
• The changed communication parameters will only be effective after the inverter is rebooted (namely, the power is changed from OFF to ON).
• During operation, it is impossible to change to auto torque boost from manual torque boost and vice versa.
47
4. Operation Method (Basic & Trial Operations)
4.8 List of Function Parameters
No.
4.8.1 List of P0 Function Parameters
Changeable
Function name during operation
Setting range
P001
The 1st Acceleration
Time
P002
The 1st Deceleration
Time
○
○
Unit
Initial Reference value page
0.0(0.04sec)•0.1~3600 0.1[sec] 5.0
0.0(0.04sec)•0.1~3600 0.1[sec] 5.0
100
101
Setting Panel value Reset*1
Control Type Content
0 Yes Panel
Run: RUN
Stop: STOP
Rotation direction: set in
“dr” mode
P003 Run Command Selection -
1 Yes
3 Yes
5 Yes
7 Yes
Panel
Communication
Forward:
Reverse:
+ RUN
+ RUN
Stop: STOP
Run: SW1 ON
Stop: SW1 OFF
Forward: SW2 OFF
Reverse: SW2 ON
Run: SW1 ON
Stop: SW1 OFF
Forward: SW2 OFF
Reverse: SW2 ON
Forward run: SW1 ON
Stop: SW1 OFF
Reverse run: SW2 ON
Stop: SW2 OFF
Forward run: SW1 ON
Stop: SW1 OFF
Reverse run: SW2 ON
Stop: SW2 OFF
Communication command
Communication command
- 0 102
48
4. Operation Method (Basic & Trial Operations)
No.
P005
Function name
Operation Status
Monitoring
P006 Vector Control Selection
S-shape
P008 Acceleration/Deceleratio n mode
P012 Max. Output Frequency
P014 Change Point Frequency 1
Changeable during operation
-
-
-
○
-
-
-
○
-
-
○
Setting range Unit
Initial Reference value page
0: Panel input
1: External Control: “VR” input
2: External Control: 0~5V
3: External Control: 0~10V
4: External Control: 4~20mA
5: External Control: 0~20mA
6: Communication: Communication command
7: External Control: PWM signal
8: External Control: pulse signal
0: Output frequency
1: Linear speed
2: Output current
3: Communication station No.
4: Set frequency
5: Communication station No./Output frequency
6: Communication station No./Linear speed
7: Communication station No./Output current
8: Winding length
0: V/F control
1: Sensorless vector control
In V/F control: 0.8~15.0 (9 options)
In sensorless vector control: 2.5~15.0 (6 options)
0: Linear acceleration/deceleration
1: S-shape acceleration/deceleration(quadratic curve)
2: S-shape acceleration/deceleration (cubic curve)
50: 50Hz mode
60: 60Hz mode
FF: Free mode
3C: 3-point mode
3C1: 3-point fixed 1
3C2: 3-point fixed 2
3C3: 3-point fixed 3
3C4: 3-point fixed 4
3C5: 3-point fixed 5
3C6: 3-point fixed 6
0: Constant torque mode
1: Reduced torque mode
0~40: Manual torque boost
Auto: Auto torque boost
50.0~400.0
-
-
-
[kHz] 2.5
-
-
-
0 104
0 105
0 106
0 107
50
0 111
1[%] 5 112
0.1[Hz] 50.0
45.0~400.0 0.1[Hz] 50.0
106
108
113
113
0.2~400.0 0.1[Hz] 0.2
114
49
4. Operation Method (Basic & Trial Operations)
No. Function name
P015 Change Point Voltage 1
Changeable during operation
○
P016 Change Point Frequency 2
P017 Change Point Voltage 2
○
○
-
○
○
○
P022
P023
P025
P026
JOG
Panel Operation
Electronic Thermal
Selection
P024 Thermal Current Setting
Overcurrent Stall
Prevention Function
Overvoltage Stall
Prevention Function
P027 Current Limit Function
-
○
○
○
○
○
○
Setting range
0.0~100.0
0.2~400.0
0.0~100.0
0 (power source voltage value), 1~500
0.2~400.0
0.0(0.04sec)•0.1~3600
0.0(0.04sec)•0.1~3600
0: Do not use the panel JOG function.
1: Use the panel JOG function(external control JOG function is unavailable).
2: Use the panel JOG function(external control JOG function is unavailable).
0: 140% of the rated current, 1min OL tripping
1: without reducing the output frequency
2: Reducing the output frequency
3: Specifications of forced air-cooled motor
0.1~100.0
0: Overcurrent Stall Prevention Function: OFF
Overcurrent Tripping Prevention Function: OFF
1: Overcurrent Stall Prevention Function: ON
Overcurrent Tripping Prevention Function: ON
2: Overcurrent Stall Prevention Function: OFF
Overcurrent Tripping Prevention Function: ON
3: Overcurrent Stall Prevention Function: ON
Overcurrent Tripping Prevention Function: OFF
0: Stall Prevention Function: OFF
1: Stall Prevention Function: ON
(the ON/OFF function of the regeneration resistor/brake resistor is disabled.)
0.0•0.1~9.9
1~200
Unit
Initial Reference value page
0.1[%] 0.0
0.1[Hz] 0.2
0.1[%] 0.0
114
114
114
1[V] 0 115
0.1[Hz] 10.0
116
0.1[sec] 5.0
0.1[sec] 5.0
116
116
-
-
0 116
2 118
0.1[A]
-
-
*4 118
1 119
1 120
0.1[sec] 0.0
1[%] 140
121
122
50
4. Operation Method (Basic & Trial Operations)
No.
P032
Function name
Ride-through Restart
Selection
P038 DC Brake Time
P039 DC Brake Level
P040
Stop Frequency during
Forward/Reverse Run
Operation
P041
DC Brake Time during
Forward/Reverse Run
Operation
P042
DC Brake Level during
Forward/Reverse Run
Operation
P043
DC Brake Time at
Start-up
P044
DC Brake Level at
Start-up
P045 Lower Limit Frequency
P046 Upper Limit Frequency
P047
Zero Stop Function
Selection
P048 The 1st Skip Frequency
P049 The 2nd Skip Frequency
Changeable during operation
○
○
-
-
○
-
○
-
○
○
○
Setting range Unit
Initial Reference value page
0: Without retry function
1: Only for overcurrent abnormality
2: Only for overvoltage abnormality
3: Only for overcurrent abnormality/overvoltage abnormality
- 0 123
1~10 1[Times]
0: Run
1: OP Stop
2: Run after the waiting time
3: OP Stop (waiting time)
0: Restart Mode 1
1: Restart Mode 2
2: Restart Mode 3
3: Restart Mode 4
-
-
1 124
0 126
0.1~100.0 0.1[sec] 0.1
128
0: Enable forward/reverse run
1: Disable reverse run
- 0 128
0.2~60.0 0.1[Hz] 0.2
128
0: Slow down and stop
1: Coast-to-stop
- 0 129
0.2~60.0 0.1[Hz] 0.2
129
0.0~120.0 0.1[sec] 0.0
130
○
○
○
○
○
○
○
-
○
○
0.2~60.0 0.1[Hz]
0.0~120.0 0.1[sec]
0.0~120.0 0.1[sec]
0.2~400.0 0.1[Hz]
0.2
0.0
0.0
0.2
0.2~400.0 0.1[Hz] 400.0
0.0•0.2~400.0 0.1[Hz]
0.0•0.2~400.0 0.1[Hz]
0.0•0.2~400.0 0.1[Hz]
0.2
0.0
0.0
131
131
132
133
133
134
135
135
51
4. Operation Method (Basic & Trial Operations)
No. Function name
P050 The 3rd Skip Frequency
P051
Skip Frequency
Bandwidth
Changeable during operation
○
○
0.0•0.20.0~400.0
0~10
P052
P056
Cooling Fan ON-OFF
Control Selection
P053 Input Terminal Filter
P054 Linear Speed Multiplier
P055 Setting Data Clear
Alarm LED Operation
Selection
○
○
○
○
Setting range Unit
0.1[Hz]
Initial Reference value
0.0
page
135
1[Hz] 0 135
0: ON when Power-on/ OFF when Power-off
(With fan tripping)
1: ON when Power-on/ OFF when the temperature of the internal switch moule is below 100℃
(With fan tripping)
2: OFF ON when Power-on/ OFF when Power-off
(Without fan tripping/giving alarm)
3: ON when Power-on/ OFF when the temperature of the internal switch moule is below 100℃
(Without fan tripping/giving alarm)
5~100
0.1~100.0
0: Normal status
1: All are set to the factory setting values except the motor constants.
2: Change all data to their factory setting values.
0: No settings
1: Full-range Monitoring and Alarming
2: Output voltage
3: Overload
4: Temperature ABNORMALITY
5: Timer stop
6: Cooling fan abnormality
- 0 136
1[Times] 20
1[Times] 3.0
-
-
137
137
0 138
0 139
P057
Upper Limit Voltage of
Alarm LED
P058
Upper Limit Current of
Alarm LED
P059 Password
○
○
○
0.1~600.0
0.1~100.0
0.1[V]
0.1[A]
-
550.0
*4
0000
139
140
140
P060
MOP Operation
Selection
○
0000~9999
0: Linkage control of the acceleration/deceleration time for
MOP Operation
1: Linkage control of the frequency setting
2: MOP function is closed
- 2 142
P061
Acceleration/deceleration
Time for MOP Operation
P062 Torque Boost Gain
P063
Torque Boost Response
Gain
○
-
-
0.0(0.04sec)•0.1~3600 0.1[sec] 5.0
142
52
4. Operation Method (Basic & Trial Operations)
4.8.2 List of P1 Function Parameters
Changeable
No. Function name during operation
Setting range
P101
SW1 Function
Selection
-
0: No settings(*2)
1(r1): Multiple segments
2(r2): Reset
3(r3): Reset lock
4(r4): JOG Selection
5(r5): External fault stop
6(r6): Parameter setting disable
7(r7): Coast-to-stop
8(r8): Frequency signal switch
9(r9): The 2 nd characteristic Selection
10(r10): PID control switch
11(r11): 3-wire stop command
12(r12): Speed search
13(r13): Temporary stopping of winding mode
14(r14): Input mode of winding length
15(r15): Clear winding length
16(r16): Run/stop
17(r17): Forward/reverse
18(r18): JOG forward run
19(r19): JOG reverse run
20(r20): Invalid
P102
SW2 Function
Selection
-
0: No settings(*2)
1(r1): Multiple segments
2(r2): Reset
3(r3): Reset lock
4(r4): JOG Selection
5(r5): External fault stop
6(r6): Parameter setting disable
7(r7): Coast-to-stop
8(r8): Frequency signal switch
9(r9): The 2 nd characteristic Selection
10(r10): PID control switch
11(r11): 3-wire stop command
12(r12): Speed search
13(r13): Temporary stopping of winding mode
14(r14): Input mode of winding length
15(r15): Clear winding length
16(r16): Run/stop
17(r17): Forward/reverse
18(r18): JOG forward run
19(r19): JOG reverse run
20(r20): Invalid
Unit
Initial value
Reference page
- 16
- 17
53
4. Operation Method (Basic & Trial Operations)
No.
P103
P104
Function name
Changeable during operation
SW3 Function
Selection
SW4 Function
Selection
-
-
Setting range
0: No settings(*2)
1(r1): Multiple segments
2(r2): Reset
3(r3): Reset lock
4(r4): JOG Selection
5(r5): External fault stop
6(r6): Parameter setting disable
7(r7): Coast-to-stop
8(r8): Frequency signal switch
9(r9): The 2 nd characteristic selection
10(r10): PID control switch
11(r11): 3-wire stop command
12(r12): Speed search
13(r13): Temporary stopping of winding mode
14(r14): Input mode of winding length
15(r15): Clear winding length
16(r16): Run/stop
17(r17): Forward/reverse
18(r18): JOG forward run
19(r19): JOG reverse run
20(r20): Frequency ▲ setting
0: No settings(*2)
1(r1): Multiple segments
2(r2): Reset
3(r3): Reset lock
4(r4): JOG selection
5(r5): External fault stop
6(r6): Parameter setting disable
7(r7): Coast-to-stop
8(r8): Frequency signal switch
9(r9): The 2 nd characteristic selection
10(r10): PID control switch
11(r11): 3-wire stop command
12(r12): Speed search
13(r13): Temporary stopping of winding mode
14(r14): Input mode of winding length
15(r15): Clear winding length
16(r16): Run/stop
17(r17): Forward/reverse
18(r18): JOG forward run
19(r19): JOG reverse run
20(r20): Frequency ▲ setting
Unit
Initial value
Reference page
- 0
- 0
54
4. Operation Method (Basic & Trial Operations)
No.
P105
P106
Function name
Changeable during operation
SW5 Function
Selection
SW6 Function
Selection
-
-
Setting range
0: No settings(*2)
1(r1): Multiple segments
2(r2): Reset
3(r3): Reset lock
4(r4): JOG selection
5(r5): External fault stop
6(r6): Parameter setting disable
7(r7): Coast-to-stop
8(r8): Frequency signal switch
9(r9): The 2 nd characteristic selection
10(r10): PID control switch
11(r11): 3-wire stop command
12(r12): Speed search
13(r13): Temporary stopping of winding mode
14(r14): Input mode of winding length
15(r15): Clear winding length
16(r16): Run/stop
17(r17): Forward/reverse
18(r18): JOG forward run
19(r19): JOG reverse run
20(r20): Frequency storage setting
0: No settings(*2)
1(r1): Multiple segments
2(r2): Reset
3(r3): Reset lock
4(r4): JOG selection
5(r5): External fault stop
6(r6): Parameter setting disable
7(r7): Coast-to-stop
8(r8): Frequency signal switch
9(r9): The 2 nd characteristic selection
10(r10): PID control switch
11(r11): 3-wire stop command
12(r12): Speed search
13(r13): Temporary stopping of winding mode
14(r14): Input mode of winding length
15(r15): Clear winding length
16(r16): Run/stop
17(r17): Forward/reverse
18(r18): JOG forward run
19(r19): JOG reverse run
20(r20): Winding length
Unit
Initial value
Reference page
- 0
- 0
55
4. Operation Method (Basic & Trial Operations)
No. Function name
P107
Pulse Input
Frequency
P108 Pulse Input Filter
P109
PWM Signal
Average Times
P110 PWM Signal Cycle
Changeable during operation
-
-
○
○
Setting range Unit
10~100 1[Times]
1~100 1[Times]
1.0~2000 0.1[msec]
Initial value
Reference page
P111 Analog Input Filter
P112
P113
Bias Frequency
Setting
Gain Frequency
Setting
○
○
○
5~200 1[Times]
P114
Analog Direction
Mode
○
0: No settings
1: Change the rotation direction based on the analog input signal (forward → reverse)
2: Change the rotation direction based on the analog input signal (reverse →forward)
- 0
P115
P116
The 2nd Bias
Frequency Setting
The 2nd Gain
Frequency Setting
○
○
P117
P118
P119
The 2nd Analog
Direction Mode
The 2nd Analog
Input Function
Selection
The 2nd Analog
Input
SignalSelection
○
-
-
○
0: No settings
1: Reverse the rotation direction based on the analog input signal (forward → reverse)
2: Reverse the rotation direction based on the analog input signal (reverse →forward)
0: The 2 nd frequency setting signal
1: Setting value of PIDcontrol (PV)
2: Base frequency + PID adjusted value
3: Base frequency + complemented frequency setting signal
2: External control: 0~5V
3: External control: 0~10V
4: External control: 4~20mA
5: External control: 0~20mA
0: Output frequency
1: Output current
-
-
-
-
0
0
2
0 P120
P121
P122
Analog Output
Function Selection
PWM Output
Duty-cycle
Compensation
PWM Output
Function Selection
○
○
0: Output frequency
1: Output current
- 0
56
4. Operation Method (Basic & Trial Operations)
No. Function name
P123 PWM Output Cycle
Changeable during operation
○
P124
P125
Output TR1
Function Selection
Output TR2
Function Selection
○
○
Setting range Unit
Initial value
Reference page
1~2000 1[msec]
0: Run signal
1: Reverse signal
2: Arrival signal
3: Overload alarm
4: Frequency detection
5: Current detection (1)
6: Current detection (2)
7: Abnormality alarm (1)
8: Abnormality alarm (2)
9: Timer stops running after a cycle
10: Timer stops running
11: Alarm
12: Speed search act
13: PWM output
14: Pulse output
0: Run signal
1: Reverse signal
2: Arrival signal
3: Overload alarm
4: Frequency detection
5: Current detection (1)
6: Current detection (2)
7: Abnormality alarm (1)
8: Abnormality alarm (2)
9: Timer stops running after a cycle
10: Timer stops running
11: Alarm
12: Speed search act
-
-
0
0
57
4. Operation Method (Basic & Trial Operations)
No.
P126
Function name
Changeable during operation
Output RY
Function Selection
○
○
Setting range Unit
Initial value
Reference page
0(r0): Run signal (*3)
1(r1): Reverse signal
2(r2): Arrival signal
3(r3): Overload alarm
4(r4): Frequency detection
5(r5): Current detection (1)
6(r6): Current detection (2)
7(r7): Abnormality alarm (1)
8(r8): Abnormality alarm (2)
9(r9): Timer stops running after a cycle
10(r10): Timer stops running
11(r11): Alarm
12(r12): Speed search act
- 0
0.0, 0.2~400.0 0.1[Hz] P127
P128
Detect Frequency
(OutputTR)
Detect Frequency
(Output RY)
P129
P130
P131
P132
Current Detection
Level
Current Detection
Delay Time
RS485
Communication
Protocol *6
RS485
Communication station No.*6
○
○
○
○
○
0.0, 0.2~400.0 0.1[Hz]
0.1~10.0 0.1[sec]
0: MEWTOCOL
1: Modbus-RTU
2: Modbus-ASCII
01~31
-
-
0
01
P133
P134
P135
RS485
Communication
Speed *6
RS485 Stop Bit
Length *6
RS485 Parity
Check *6
○
○
○
○
48: 4800
96: 9600
192: 19200
384: 38400
576: 57600
1152: 115200
1: 1bit
2: 2bit
0: No check
1: Odd number
2: Even number bps 96 176
- 0
0.0•0.1~60.0 0.1[sec] P136
P137
RS485 Timeout
Sensing *6
RS485 Wait-to-send
Time *6
○ 1~1000 1[msec]
58
4. Operation Method (Basic & Trial Operations)
No. Function name
Changeable during operation
P138
P139
P140
RS485 Judging
Time for TEXT
Completion *6
The 2nd Base
Frequency
The 2nd Torque
Boost *7
○
○
P141
The 2nd Electronic
Thermal Selection
○
Setting range
3~200 1[msec]
45.0~400.0 0.1[Hz]
0~40: manual torque boost
Auto: auto torque boost
0: 140% of the rated current, 1min OL tripping
1: without reducing the output frequency
2: Reducing the output frequency
3: Specifications of forced air-cooled motor
Unit
Initial value
Reference page
1[%] 5 179
-
50.0
178
2
P142
P143
P144
The 2nd Thermal
Current Setting
The 2nd Change
Point
Frequency 1
The 2nd Change
Point
Voltage 1
P145
P146
P147
P148
The 2nd Change
Point
Frequency 2
The 2nd Change
Point
Voltage 2
Pulse Output
Frequency
Pulse Output
Duty-cycle
P149
Analog Output
Voltage
Compensation
○
○
○
○
○
○
○
○
0.2~400.0 0.1[Hz]
0.2~400.0 0.1[Hz]
1.0~10.0 0.1[kHz]
59
4. Operation Method (Basic & Trial Operations)
4.8.3 List of P2 Function Parameters
Changeable
No. Function name during operation
Setting range
0: Heavy load rating
P201 Load Rating -
P202 Auto-tuning -
1: Light load rating
0: Without tuning
1: Full band tuning
P203 Motor Capacity
P204
Motor Pole
Number
-
-
0.2: 0.2kW
0.4: 0.4kW
0.7: 0.75kW
1.5: 1.5kW
2.2: 2.2kW
3.7: 3.7kW
5.5: 5.5kW
7.5: 7.5kW
11.: 11kW
15.: 15kW
2: 2 poles
4: 4 poles
6: 6poles
P205
P206
P207
P208
P209
P210
P211
P212
P213
P214
P215
Rated Voltage of
Motor
Rated
Frequency of
Motor
Rated Current of
Motor
Primary
Resistance
Secondary
Resistance
Energizing
Inductance
Leakage
Inductance
Energizing
Current
Speed Control
Percentage
Increment
Speed Control
Integral Increment
Torque Limit
Level
-
Initial Reference value page
- 10.0~120.0 0.1[Hz] 50.0
- 0.01~99.99 0.01[A] *4
- 0.00~99.99 0.01[Ω] *4
- 0.00~99.99 0.01[Ω] *4
- 0.0~999.9, 1000~5000 (Unit: 1mH)
Unit
- 0 183
- 0 184
- *4
Poles
0.1[mH] *4
- 0.0~999.9 0.1[mH] *4
- 0.01~99.99 0.01[A] *4
- 0.01~10.00 0.01
- 0.01~10.00 0.01
- 50~400 1[%]
4 185
*4
*4
220
185
185
185
186
186
186
186
186
187
187
188
60
4. Operation Method (Basic & Trial Operations)
No. Function name
Changeable during operation
P216
The 2 nd
Motor
Capacity
0.2: 0.2kW
0.4: 0.4kW
0.7: 0.75kW
1.5: 1.5kW
2.2: 2.2kW
3.7: 3.7kW
5.5: 5.5kW
7.5: 7.5kW
11.: 11kW
15.: 15kW
2: 2 极
4: 4 极
6: 6 极
P217
Poles Number of the 2nd Motor
P218
P219
P220
P221
P222
P223
P224
P225
P226
P227
P228
Rated Voltage of the 2nd Motor
Rated Frequency of the 2nd Motor
Rated Current of the 2nd Motor
Primary
Resistance of the
2nd Motor
Secondary
Resistance of the
2nd Motor
Energizing
Inductance of the
2nd Motor
Leakage
Inductance of the
2nd Motor
Energizing
Current of the 2 nd
Motor
Speed Control
Percentage
Increment of the
2nd Motor
Speed Control
Integral Increment of the 2nd Motor
Torque Limit
Level of the 2nd
Motor
Setting range
Initial Reference value page
10.0~120.0 0.1[Hz] *4
0.01~99.99 0.01[A] *4
0.00~99.99 0.01[Ω] *4
0.00~99.99 0.01[Ω] *4
0.0~999.9, 1000~5000 (Unit: 1mH)
Unit
- *4
极 4 189
0.1[mH] *4
0.0~999.9 0.1[mH] *4
0.01~99.99 0.01[A] *4
0.01~10.00 0.01
0.01~10.00 0.01
50~400 1[%]
*4
*4
220
189
189
189
190
190
190
190
190
191
191
192
61
4. Operation Method (Basic & Trial Operations)
4.8.4 List of P3 Function Parameters
Changeable
No. Function name during operation
Setting range
P301
Multi-step speed
Function
Selection
-
0: Multi-step speed frequency operation function
1: The 2 nd
/3 rd
/4 th acceleration/deceleration operation function
2: Acceleration/deceleration linked with multi-step speed frequency operation function
3: Timer controlled multi-step speed frequency operation
4: Timer controlled acceleration/deceleration linked with multi-step speed frequency operation
P302
P303
P304
P305
P306
P307
P308
P309
P310
P311
P312
P313
P314
P315
P316
P317
P318
P319
P320
P321
P322
P323
P324
The 2nd Speed
Frequency
The 3rd Speed
Frequency
The 4th Speed
Frequency
The 5th Speed
Frequency
The 6th Speed
Frequency
The 7th Speed
Frequency
The 8th Speed
Frequency
The 9th Speed
Frequency
The 10th Speed
Frequency
The 11th Speed
Frequency
The 12th Speed
Frequency
The 13th Speed
Frequency
The 14th Speed
Frequency
The 15th Speed
Frequency
The 16th Speed
Frequency
The 2nd
Acceleration Time
The 2nd
Deceleration Time
The 3rd
Acceleration Time
The 3rd
Deceleration Time
The 4th
Acceleration Time
The 4th
Deceleration Time
Rotation Direction of Timer Operation
Continuous
Operation Times of
Timer
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
-
○
Unit
Initial value
Reference page
- 0 193
0.0, 0.2~400.0 0.1[Hz] 5.0
0.0, 0.2~400.0 0.1[Hz] 10.0
0.0, 0.2~400.0 0.1[Hz] 12.5
0.0, 0.2~400.0 0.1[Hz] 15.0
0.0, 0.2~400.0 0.1[Hz] 17.5
0.0, 0.2~400.0 0.1[Hz] 20.0
0.0, 0.2~400.0 0.1[Hz] 22.5
0.0, 0.2~400.0 0.1[Hz] 25.0
0.0, 0.2~400.0 0.1[Hz] 27.5
0.0, 0.2~400.0 0.1[Hz] 30.0
0.0, 0.2~400.0 0.1[Hz] 32.5
0.0, 0.2~400.0 0.1[Hz] 35.0
0.0, 0.2~400.0 0.1[Hz] 40.0
0.0, 0.2~400.0 0.1[Hz] 45.0
0.0, 0.2~400.0 0.1[Hz] 50.0
0.1~3600 0.1[sec] 5.0
0.1~3600 0.1[sec] 5.0
0.1~3600 0.1[sec] 5.0
0.1~3600 0.1[sec] 5.0
0.1~3600 0.1[sec] 5.0
0.1~3600 0.1[sec] 5.0
0~255
0•1~9999 1[Times]
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
- 0 201
62
4. Operation Method (Basic & Trial Operations)
No. Function name
Changeable during operation
P325
Continuous
Operation Mode of
Timer
P326
P327
P328
P329
P330
P331
P332
P333
P334
Continuous Waiting
Time of Timer
The 1st Speed
Runtime
The 2nd Speed
Runtime
The 3rd Speed
Runtime
The 4th Speed
Runtime
The 5th Speed
Runtime
The 6th Speed
Runtime
The 7th Speed
Runtime
The 8th Speed
Runtime
○
○
○
○
○
○
○
○
○
○
Setting range Unit
Initial value
Reference page
0: Return to zero position/stop status, and change to the next cycle.
1: Change to the 1 st
Speed Frequency of the next cycle.
- 0 203
0.0•0.1~6553 0.1[sec] 0.0
203
0.0•0.1~6553 0.1[sec]
0.0•0.1~6553 0.1[sec]
0.0•0.1~6553 0.1[sec]
0.0•0.1~6553 0.1[sec]
0.0•0.1~6553 0.1[sec]
0.0•0.1~6553 0.1[sec]
0.0•0.1~6553 0.1[sec]
0.0
0.0
0.0
0.0
0.0
0.0
0.0
204
204
204
204
204
204
204
P335
Winding Mode
Control Selection
P336
P337
P338
P339
Amplitude in
Winding Mode
Recoil Frequency
Band in Winding
Mode
Winding Mode
Cycle
Rise Time
Coefficient in
Winding Mode
○
○
○
○
○
0.0•0.1~6553 0.1[sec] 0.0
0: Winding mode control: OFF
1: Set frequency standard
2: Max. frequency standard
-
0.0~100.0 0.1[%] 50.0
204
0 205
205
0.0~100.0 0.1[%]
0.0~3600 0.1[sec]
0.0~100.0 0.1[%]
10.0
10.0
50.0
205
205
205
P340
Winding Mode
Operation Selection
-
-
0: Normal Mode
1: 2-point normal mode
2: Random Swinging Mode
3: 2-point Random Swinging Mode
- 0 206
0.0~100.0 0.1[%] 50.0
207 P341
P342
P343
P344
Max. Random Rise
Time Coefficient
Min. Random Rise
Time Coefficient
Winding Length
Multiplier
Winding Stop
Length
P345 PID Target Value
P346
P347
PID Upper Limit
Value
PID Lower Limit
Value
P348 PID Bias Value
P349
Proportional Gain
[Kp]
-
-
-
○
○
○
○
○
0.0~100.0 0.1[%]
0~9999
0.0~100.0 0.1[%]
0.0~100.0 0.1[%]
0.0~100.0 0.1[%]
- 100~100.0 0.1[%]
0.1~1000
-
-
50.0
1 207
0.0
100.0
0.0
100.0
1.0
207
208
208
209
209
209
63
4. Operation Method (Basic & Trial Operations)
No. Function name
P350 Integral Time[Ti]
Changeable during operation
○
○
P352 Control Cycle [Ts]
P354
PIDOutput
Reverse
Selection
○
-
-
○
Setting range Unit
Initial value
Reference page
0.00~360.0 0.01[sec] 0.00
0.00~10.00 0.01[sec] 0.00
209
209
0.00~60.00 0.01[sec] 0.00
0: Inverse Operation
1: Forward operation
0: Reverse operation is invalid.
1: Reverse operation is valid.
-
-
210
0 210
0 210
0.0•0.2~400.0 0.1[Hz] 0.0
211
P357
Sleep Operation
Speed Search
Selection at
Startup
P360
Waiting Time
Speed Search
Voltage Recovery
Time
○
○
○
○
0.0~25.0 0.1[sec] 0.0
0: Valid
1: Invalid
-
0.0~100.0 0.1[sec] 0.5
211
0 211
212
0.0~10.0 0.1[sec] 0.5
212
P364
Retry Times
Speed Search
Upper Limit
Frequency
Selection
○
○
○
○
0: Invalid
1: Valid
0: Error reporting stops
1: Start the frequency operation
-
-
0 212
0~10 1[Times]
0
212
0: Below Max. frequency
1: Below the previous frequency value before the coast-to-stop operation.
- 0 213
*1: After an abnormal tripping, if the stop signal from external operation cannot reset it, use the
STOP button on the operation panel to make a reset.
However, if the reset lock function is enabled, the reset lock function shall take precedence, yet the reset function is also valid.
*2: If the setting value displays “r”, it is a “b” contact operation. (If no “r” is displayed, then it is an “a” contact operation.)
*3: If the setting value displays “r”, then it is a non-exciting operation when it is
ON. (If no “r” is displayed, then it is an exciting operation when it is ON.)
*4: The initial values vary with the different capacities of inverters.
*5: The initial values vary with the different applicable input voltages of inverters.
The initial value is 200 at 200V, 380 at 400V.
*6: It is effective when the power is OFF. (All changed parameters will apply after the power is turned from OFF to ON.)
*7: During operation, it is impossible to change to auto torque boost from manual torque boost and vice versa.
64
4. Operation Method (Basic & Trial Operations)
4.9 Operation Method
There needs operation command and frequency command for the inverter. The motor will rotate when the operation command is set to ON, in this case, the rotating speed of the motor shall be determined by the frequency command
(set frequency).
Please make a setting according to the following flow chart.
Operation command ?
Operating via the
“
RUN
” button on the operation panel
Refer to 4.10 (Page 66)
Input signal from external device into the input control circuit to drive the operation
Refer to 4.11 (Page 69)
Operating according to the communication command
Refer to “MK300
Communication
Manual”
Frequency command ?
Setting via the operation panel
Setting via the external potentiometer
Setting via the voltage output device
Setting via the current output device
Refer to 4.10 (Page 66) Refer to 4.12 (Page 70) Refer to 4.12 (Page 70) Refer to 4.12 (Page 70)
Setting via communication
Refer to “MK300
Communication Manual”
Setting based on the pulse output of the external device
Setting based on the PWM output of the external device
Refer to 4.12 (Page 70) Refer to 4.12 (Page 70)
65
4. Operation Method (Basic & Trial Operations)
4.10 Operating via Operation Panel
【 Wiring Example】
AC power supply
R/L1
S/L2
T/L3
Operation Panel
U
V
W
Motor
Please set parameter P003 to “0” or “1” when operating via operation panel.
Note that the setting of rotation direction varies with different setting values.
4.10.1 Operating via Operation Panel and Changing of the Set
Frequency - 1(when P003=0)
During operation, please pay full attention to the safety of the surrounding of the motor and other machines.
Make sure that the wiring of the motor is correct.
【 Factory Setting】
① Turn on the power.
The display part with be ON immediately after power on. (Operation Status Display Mode)
② Press
RUN .
The motor rotate at the frequency of 0.2Hz.
Confirm the rotation direction of the motor.
【 Changing Frequency】
Method 1: change the setting of “Fr”
RUN
③ Press
MODE
to show “Fr”.
MODE
④ Press the panel knob.
⑤ Rotate the panel knob to set the frequency to
“50.0Hz”.
66
4. Operation Method (Basic & Trial Operations)
⑥ Press the panel knob to cause the motor to
⑦ Press
MODE
to show the operation frequency.
⑧
Press
STOP
to cause the motor to start decelerating and stop when it displays “0000”.
【
Changing the rotation direction
】
① Press
MODE
to show “Fr”.
② Rotate the panel knob to show “dr” (Direction
Setting Mode) .
③ Press the panel knob.
MODE
STOP
MODE
④ Rotate the panel knob to select “L-r”.
⑤ Press the panel knob.
⑥ Press
MODE
.
MODE
Press
RUN
to cause the motor to start running in
⑦ a reverse direction until the frequency becomes
“50Hz”.
RUN
⑧
Press
STOP
to cause the motor to start decelerating and stop when it displays “0000”.
STOP
• During operation, you can also make this change through these procedures.
67
4. Operation Method (Basic & Trial Operations)
4.10.2 Operating via Operation Panel and Changing of the Set
Frequency - 2(when P003=1)
① Turn on the power.
The display part with be ON immediately after power on. (Operation Status Display Mode)
② Counterclockwisely rotate the panel knob to show “L-F”. (Clockwaisely rotate the encoder to show “L-r”)
③ Press
RUN .
The motor rotate forward at the frequency of
Confirm the rotation direction of the motor.
RUN
④ Press
MODE
to show “Fr”.
MODE
⑤ Press the panel knob.
⑥ Rotate the panel knob to set the frequency to
“50.0Hz”.
⑦ Press the panel knob.
The motor accelerates to “50.0Hz”.
⑧ Press
MODE
.
⑨ Counterclockwisely rotate the panel knob to show “L-r”;
(Clockwaisely rotate the encoder to show
“L-F”)
⑩ Press
RUN to cause the motor to decelerate to
“0Hz”, then the motor will reversely run at the frequency of “50.0Hz”.
⑪
Press
STOP
to cause the motor to start decelerating and stop when it displays “0000”.
MODE
RUN
STOP
68
4. Operation Method (Basic & Trial Operations)
4.11 Operating based on External Input Signal
It can be operated based on the external input signals when the parameter
P003 is set to “2” to “5”.
Note that the changing of the rotatation direction for the setting value of “2”, “3”,
“4” and “5” is different.Wiring
【 Wiring Example: when P003 = 2 or 3】
AC power supply
R/L1
S/L2
T/L3
U
V
W
Motor
ON: Run OFF: Stop
ON: Reverse OFF: Forward
① ※ 1
② ※ 1
⑦ (Common
Terminal )
※ 1 ① be set.
※ 2 No example of wiring for frequency setting signal is provided.
②
For the setting of frequency, please refer to “4.11 Operating based on
External Input Signal”, it is set at the same time as the wiring.
【 Wiring Example: when P003 = 4 or 5】
AC power supply
R/L1
S/L2
T/L3
U
V
W
Motor
ON: Forward Run OFF: Stop
ON: Reverse Run OFF: Forward
① ※1
② ※1
⑦ (Common
Terminal )
※ 1 ① be set.
※ 2 No example of wiring for frequency setting signal is provided.
②
For the setting of frequency, please refer to “4.11 Operating based on
External Input Signal”, it is set at the same time as the wiring.
69
4. Operation Method (Basic & Trial Operations)
4.12 Setting Frequency via External Device
The frequency can also be set according to the output signal from the external device in addition to methods of setting via the operation panel and communication.
Frequencies corresponding to various output signals can be set by changing the parameter P004.
【 Wiring Example: when setting via the potentiometer input (P004 = 1)】
AC power supply
R/L1
S/L2
T/L3
U
V
W
Motor
Potentiometer
( VR)
⑪
⑫
⑭
(Common
Terminal )
※ 1 No example of wiring for operation command signal is provided.
For the operation command signal, please refer to “4.11 Operating based on External Input Signal”, it is set at the same time as the wiring.
• Please choose a potentiometer with the specifications higher than 10kΩ and 1/4W.
【 Wiring Example: when setting via the voltage output device (P004 = 2 or 3)】
AC power supply
R/L1
S/L2
T/L3
U
V
W
Motor
0 to 5V voltage output signal
0 to 10V voltage output signal
}
‐
+ ⑫
⑭ (Common
Terminal )
※ 1 No example of wiring for operation command signal is provided.
For the operation command signal, please refer to “4.11 Operating based on External Input Signal”, it is set at the same time as the wiring.
• Set parameter P004 to “2” when the output signal from the external device is in the range of 0 to 5V.
• Set parameter P004 to “3” when the output signal from the external device is in the range of 0 to 10V.
Related Parameters P047, P111~P114
70
4. Operation Method (Basic & Trial Operations)
【 Wiring Example: when setting via the current output decvice (P004 = 4 or 5)】
AC power supply
R/L1
S/L2
T/L3
U
V
W
Motor
4 to 20mA current signal
0 to 20mA current signal
} +
‐
⑫
⑭ (Common
Terminal )
※ 1 No example of wiring for operation command signal is provided.
For the operation command signal, please refer to “4.11 Operating based on
External Input Signal”, it is set at the same time as the wiring.
• Set parameter P004 to “4” when the output signal from the external device is in the range of 4 to 20mA.
• Set parameter P004 to “5” when the output signal from the external device is in the range of 0 to 20mA.
Related ParametersP047, P111~P114
【 Wiring Example: When setting based on the PWM signal (P004 = 7)】
AC power supply
R/L1
S/L2
T/L3
U
V
W
Motor
+
⑥
PWM signal
–
⑦
(Common
Terminal )
※ 1 No example of wiring for operation command signal is provided.
For the operation command signal, please refer to “4.11 Operating based on
External Input Signal”, it is set at the same time as the wiring.
Be sure to set the following parameters when setting the frequency based on the PWM signal. Moreover, they should only be used after the notes for every parameter had been carefully read.
Parameter
No.
Function name Unit Setting range Initial Value
P109
PWM Signal Average
Times
1[Times] 1 ~ 100 1
0.1[msec] 1.0
~ 2000 1.0
71
4. Operation Method (Basic & Trial Operations)
【 Wiring Example: When setting based on the pulse signal (P004 = 8)】
AC power supply
R/L1
S/L2
T/L3
U
V
W
Motor
+
⑥
Pulse signal
–
⑦
(Common
Terminal )
※ 1 No example of wiring for operation command signal is provided.
For the operation command signal, please refer to “4.11 Operating based on
External Input Signal”, it is set at the same time as the wiring.
Be sure to set the following parameters when setting the frequency based on the pulse signal. Moreover, they should only be used after the notes for every parameter had been carefully read.
Parameter
No.
Function name Unit Setting range Initial Value
P108
Input 1[kHz] 1.0
~ 40.0 1.0 frequency
Pulse Input Filter 1[msec] 10 ~ 100 50
72
4. Operation Method (Basic & Trial Operations)
4.13 V/F Control Setting
MK300 supports the V/F control and the sensorless vector control.
In the V/F control mode, the output voltage of the inverter is proportional to its output frequency.
■ Steps for Setting the V/F Control:
· Setting Example: change the max. output frequency from 50.0Hz to 60.0Hz (that is, change the value of parameter P012 fro “50.0” to “60.0”)
① It displays “0000” when the inverter is powered ON.
② Set P006 to “0”.
•Refer to “4.8 Parameter Setting” for the setting of parameters.
③ Set P009 to “50”.
•Refer to “4.8 Parameter Setting” for the setting of parameters.
•Different V/F modes are available for the function parameter
P009.
P009 Setting value
Corresponding VF mode
P009 Setting value
Corresponding VF mode
50 50Hz mode 3C2 3-point fix mode 2
60
FF
3C
60Hz mode
Free mode
3-point mode
3C3
3C4
3C5
3-point fix mode 3
3-point fix mode 4
3-point fix mode 5
3C1 3-point fix mode 1 3C6 3-point fix mode 6
Refer to the detailed explanation about the function parameter P009 for the details of various modes.
④ Set P012 to “50.0”. and cannot be modified.
•In the 60Hz mode, P012 will be automatically set to “60.0” and cannot be modified.
•In other modes, P012 needs to be set manually.
•Refer to “4.8 Parameter Setting” for the setting of parameters.
•In the 50Hz mode, P013 will be automatically set to “50.0” and cannot be modified.
•In the 60Hz mode, P013 will be automatically set to “60.0” and cannot be modified.
•In other modes, P013 needs to be set manually.
•Refer to “4.8 Parameter Setting” for the setting of parameters.
⑥ After the above steps had been completed, the control mode operated through the V/F control.
73
4. Operation Method (Basic & Trial Operations)
4.14 Auto-tuning
When operating in the sensorless vector control mode, or operating the auto torque boost in the V/F control mode, be sure to perform the auto-tuning for all motores before their first operation. Otherwise, they cannot be controlled normally. Measure the motor constants for control use and automatically save them to parameter P208 to P212 (for the 2 nd motor: P216 to P220)
The inverter will automatically drive the motor within the range of uppter/lower frequency limit after the auto-tuning starts.
Do not start an auto-tuning if there is a danger with the motor that is being driven.
Do not approach the unit and the conductive parts during auto-tuning.
Failure to do so may result in injury and accidents.
· Do not connect loads and other objects to the motor shaft during auto-tuning. It is suggested that it should be done in the standalone status.
The auto-tuning cannot be normally performed if loads and objects with greater inertia are connected.
Perform the auto-tuning in a free rotation state without loads as far as possible.
· Start the auto-tuning only after the motor had come to a complete stop.
■ Auto-tuning Procedure:
· Perform it in the following order (1 to 4).
1.Set motor specifications with the parameters P203 to P207 (for the 2 nd motor: P216 to P220).
· Be sure to set them before the start of the auto-tuning.
2.For the 2 nd motor only: switch to the 2 nd Characteristics Selection status.
· Switch the selection status by inputing control signals.
(Refer to parameters P101 to P106.)
3.After setting P202 to “1”, swich to the Operation Status Display mode by pressing the
MODE
button.
· It will enter the measurement ready status after the panel displays “Att1”.
(Reset P202 to “0” to exit the ready status if needed.)
< Lighting up >
74
4. Operation Method (Basic & Trial Operations)
4.Press
RUN button to perform the auto-tuning.
· In the “Att1” lighting-up status, press
RUN button to automatically start the measurement. The displaying parts show as follows with the progress of the measurement.
· Press
RUN button only after it is confirmed that the motor had completely stopped.
· It takes about 2 minutes for the measurement to end.
· If the measurement needs to be stopped halfway, press
STOP button. The motor constants will not be saved if it is stopped before it displays “End” (“Att1” to
“Att3” flashing) and it will return to the measurement ready status (3.).
(Reset P202 to “0” to exit the ready status if needed.)
· It will display “End” if the measurement ends normally, and the motor constants will be saved.
Press
STOP button in the “End” displaying status to return to the normal status.
(P202 will automatically return to “0”.)
<
< Lighting up >
Flashing >
Measurement Ready Status
RUN
Press
Error
< Flashing >
Error
< Flashing >
Error
< Lighting up >
Normally end and motor constants are saved
STOP
Press
< Lighting up >
Return to normal status
· During measurement, if errors occur and it displays “t.Er1~3”, press
STOP button to return to the measurement ready status (3.). Check the configuration and wiring, and restart the automatic measurement after it is confirmed that the motor had completely stopped.
· If errors still occur in the new measurement after the configuration and wiring status had been ensured, please temperately reset P202 to “0” to exit the ready status and confirm again the specifications of the motor.
75
4. Operation Method (Basic & Trial Operations)
4.15 Vector Control
In sensorless vector control mode, the output current of inverter can be divided into the energizing current and the torpque current in the vector operation and make a compensation for the frequency and voltage to ensure that the current flowing into the motor matches up with the load torque.
This function is effective for the case that the load fluctuates sharply when high start-up torque or sufficient torque at lower speed is required.
In sensorless vector control mode, please use the inverter in the following conditions.
· A squirrel-cage induction motor should be selected.
· Please select the inverter with the capacity equivalent to or 1 level higher than the motor capacity.
· The motor must be a 2-pole, 4-pole or 6-pole one.
· It must operate in standalone mode (i.e. one motor is driven by one inverter).
· The maximum wiring length between the inverter and the motor must not exceed 30m.
· The carrier frequency should be higher than 2.5kHz.
If the above conditions are not satisfied, sound operation performance cannot be achieved.
· Uneven rotations occur more often than in the V/F control mode. It is not applicable to the load whose minor rotation may cause problems at lower speed.
In this case, V/F control should be selected.
· The output frequency ranges from 0.5Hz to 120Hz when the sensorless vector control is selected.
· The “P007: carrier frequency” is only effective in the frequency range of 2.5kHz to15.0kHz when the sensorless vector control is selected.
The setting value of carrier frequency shall be automatically changed to 2.5kHz if the “P007: Vector Control Selection” is set to “1” (sensorless vector control) in the condition that the carrier frequency is set to “0.8kHz to 1.6kHz”.
· In sensorless vector control mode, carrier frequency in area where output frequency is relatively lower may vary accordingly.
76
4. Operation Method (Basic & Trial Operations)
【 Setting Procedure for Sensorless Vector Control】
Make a setting and carry out the trial operation in the following order (1 to 4).
1. Selecting the inverter control mode
· In “P006: Vector Control Selection” mode, you may select the V/F control mode or the sensorless vector control mode.
It had been initially set to V/F control mode, therefore, it is necessary to change it to sensorless vector control mode (P006 = “1”).
2. Setting based on various specifications of the motor
The following setting values shall be taken as the benchmark for the auto-tuning, so be sure to set them before the start of the auto-tuning (parameter P202).
1) Setting of Motor Capacity:
· Set the applied motor capacity to “P203: Motor Capacity”.
The initial value of the “Motor Capacity” had been set equivalent to the
“Inverter Capacity”.
2) Setting of Motor Polarity:
· Set the applied motor polarity to “P204: Motor Pole Number”.
The initial value of the “Motor Polarity” had been set to “4 poles”.
3) Setting of Motor Rated Voltage
· Set the applied motor rated voltage to “P205: Motor Rated Voltage”.
The initial value of the “Motor Rated Voltage” had been set to “380V” (in the
400V mode)”.
4)Setting of Motor Rated Frequency
· Set the applied motor rated frequency to “P206: Motor Rated Frequency”.
The initial value of the “Motor Rated Frequency” had been set to “50Hz”.
5) Setting of Motor Rated Current
· Set the applied motor rated current to “P207: Motor Rated Current”.
· The specifications of the motor are generally specified according to the combinations of the rated voltage, rated frequency and rated current.
【 For example】380V/50Hz/1.0A,400V/60Hz/1.5A
The rated voltage should be set only after the power voltage in practical use input to the inverter MK300 had been selected.
Moreover, the rated current varies with the rated voltage and the rated frequency, be sure to set them after the combination had been confirmed.
77
4. Operation Method (Basic & Trial Operations)
3. Setting of Motor Constants
Be sure to perform the auto-tuning after the specifications of motor had been set.
· Do not connect loads to the motor shaft during auto-tuning. It is suggested that it should be done in the standalone status. The auto-tuning cannot be normally performed if loads and objects with greater inertia are connected. Perform the auto-tuning in a free rotation state without load as far as possible.
· Start the auto-tuning only after the motor had completely stopped.
Refer to “4.14 Auto-tuning” for the auto-tuning procedure.
4. Trial Operation
Perform the trial operation only after the operation command and the speed command had been set.
Please set various functions (acceleration time, deceleration time, max. output frequency) according to the need.
The settings shall be finished if the required motor characteristics had been achieved.
Related Parameters: P006, P201~P228
78
5
Troubleshooting
5.1 Safety Precautions ..........................................80
5.2 Abnormality Diagnostic Function and Reset Method ...........80
5.3 Handling Abnormality ......................................83
79
5. Troubleshooting
5.1 Safety Precautions
Wait at least fiv e minutes after turning off the input power before starting the maintenance and inspection work.
Failure to do so may result in electric shock.
Maintenance, inspection and part replacement work must be done only by qualified persons.
(Remove metal articles such as watch, bracelet(s) etc. before operation.)
(Please use insulated tools.)
Failure to do so may result in electric shock or injury.
5.2 Abnormality Diagnostic Function and Reset Method
5.2.1 Details and Remedies for Various Fault Trips
The fault trip memory stores the causes of trip in monitor modes n16 to n19.
Even if the power is cut off, the fourth to the latest causes of trip will still be held.
(Details of factory inspection are stored in the memory before delivery.)
Indication Details and causes of abnormality Remedies
SC1
SC2
SC3
SC4
SC5
SC6
OC1
OC2
OC3
OU1
· Instantaneous overcurrent during acceleration
· Instantaneous overcurrent at constant speed
· Instantaneous overcurrent during deceleration
· Instantaneous overcurrent during acceleration/deceleration or at constant speed
·
Short circuit & overcurrent at the output side at start-up
·
Faults detected at startup
· Overcurrent during acceleration
· Overcurrent at constant speed
· Overcurrent during deceleration
·
Internal DC over-voltage during acceleration
· Check if there is any output short-circuit or ground short-circuit.
·Remove sharp variations at load side.
· Extend time acceleration/deceleration
(parameters P001, P002, P317 to P322).
· Stop open and close operation of magnetic contactor at load side.
·
Check if there is any output short-circuit or ground short-circuit.
· Check the power module faults (out-source repair services).
· Check output for open phase and remove sharp variations at load side. time · Extend acceleration/deceleration
(parameters P001, P002, P317 to P322).
· Adjust torque boost level (parameter P011).
·
Check for restart operation during normal operation.
·
Stop open and close operation of magnetic contactor at load side.
· Extend acceleration time (parameters P001,
P317, P319, P321).
80
5. Troubleshooting
Indication
OU2
OU3
LU
OL
OH
AU
OP
FAN
SEr
CPU
Details and causes of abnormality Remedies
·
·
·
·
Internal DC over-voltage at constant speed
Internal DC over-voltage during deceleration
Power supply voltage below 85% of its rating
The output current exceeds 125% o f electronic thermal setting current or 140% of rated current of inverter for more than 1 minute.
· Heat sink overheating
·
External fault stop input signal is input from control circuit terminals.
· The power is turned ON with run signal ON.
· Timeout detected
· The communication cable comes off.
· Cooling fan abnormality
· Speed search failed
· Incorrect motor rotation direction
·
The rating of the motor is too small compared with that of inverter.
·
Motor rotates slowly during normal operation.
· Too much interference is applied to the inverter
· Remove sharp variations at load side.
· Extend deceleration time (parameters P002,
P318, P320, P322).
· Measure the power supply voltage and che ck input for open phase;
· Check ride-through restart function.
· Check the setting current of electronic thermal;
· Check and adjust the torque boost lev el
(parameter P011)
·
Reduce load
·
·
Check ambient temperature
·
Check if the external signal is p roper and i f timing circuit is correct.
· Check start mode (parameter P031)
· Check communication setting and wiring.
· Reduce the interference around the inverter.
Check if the cooling fan is locked.
· Reduce the noise around the inverter.
· Check the rotation direction of motor.
· Reduce the interference around the inverter.
ErrC · Too much interference is applied to the inverter · Reduce the interference around the inverter.
· Error information “SC6” refers to the error of power module fault detected in the inverter.
Please inquire the distributor from whom you purchased this product or the maintenance department of our Company about the product repair.
81
5. Troubleshooting
5.2.2 Resetting Fault Trips
If the abnormality indicator in the display part of operation panel lights up and operation is stopped, please handle the ab normality before resetting the operation.
Reset by power
Reset by stop signal
Reset by panel
Reset by multi-function terminal
Reset by communication command
The reset can be made by cutting off the power once.
(The inverter can operate when powered on again.)
① For the operation in panel setting mode (parameter P003 is set to “0” or“1”), press
STOP
button on the operation panel to reset, and then restart the inverter.
② For the operation in external control mode (parameter P003 is set to “2” or“4”), turn off the OPERATION COMMAND button designed for external control once to reset, and then restart the inverter.
Note: Reset by stop signal cannot be made through communication.
For the operation in external control or communication setting mode
(parameter P003 is set to “3”, “5”, or “7”) , the reset cannot be made even if
OPERATION COMMAND button designed for external control or communication is turned OFF once.
Press
STOP button on the operation panel to reset, and then restart the inverter.
Set parameters P101 to P106 to “2” “r2”;
Then turn the function setting switch ON once and OFF again to perform the reset.
Then restart the unit again.
Write 0x9696 into register No. 505 (DT505) to reset the inverter.
· If the error information “SC6” or “CPU” is indicated, the mod es of “reset by stop signal”, “reset b y panel”, “reset by multi-function terminal” or “reset b y communication” are disabled, in this case, only the mode of “reset by power” is enabled.
82
5. Troubleshooting
5.3 Handling Abnormalities
5.3.1 The motor does not rotate. (When abnormality indicator lights out.)
5.3.2 The motor does not rotate. (When abnormality indicator lights up)
When abnormality indicators light up but the motor does not rotate, please check out the following two items.
1. Check whether the abnormality occurs for the first time or immediately after the initial installation or during operation.
2. Check w hether the abnormality is caus ed by inverter failur e (defect) or incorrect wiring and motor failure.
83
5. Troubleshooting
5.3.3 Breaker Trip
5.3.4 Motor Overheating
5.3.5 Communication Failed
84
6
Maintenance and Inspection
6.1 Safety Precautions ..........................................86
6.2 Precautions on Inspection ...............................86
6.3 Inspection Items ..............................................86
6.4 Component Replacement................................87
6.5 Maintenance and Inspection Table ..................88
85
6. Maintenance and Inspection
6.1 Safety Precautions
Wait at least five minutes after turning off the input power before starting the maintenance and inspection work.
Failure to do so may result in electric shock.
Maintenance, inspection and part replacement work must be done only by qualified persons.
(Remove metal articles such as watch, bracelet(s) etc. before operation.)
(Please use insulated tools.)
Failure to do so may result in electric shock or injury.
Do not replace the cooling fan when power is ON. Failure to do so may result in electric shock
Employ an electrical engineering company to periodically tighten the terminal screws.
Loose terminal screws could lead to overheating or fire.
6.2 Precautions on Inspection
· To measure the insulation resistance between the power supply cable and the motor cable with a megger, always disconnect the wires connected to the inverter first before measuring. Do not make such measurement on the control circuit.
· The inverter is mainly consisted of semiconductor elements. To prevent the negative effects arising from the temperature, humidity, dust and vibration etc. in working environment and the malfunctions caused by components’ aging and service life, please perform daily inspection.
The following table shows the standard replacement interval (years) under normal working conditions (average annual ambient temperature = 30°C, load factor < 80% and average daily operation period < 12 h).
6.3 Inspection Items
1. Daily inspection: Basically check if abnormality occurs during operation.
A multimeter is normally used to check the input and output voltages of the inverter during operation.
2. Periodic inspection: To check all locations where inspection can be performed only when the inverter is stopped and where periodic inspection is required.
86
6. Maintenance and Inspection
6.4 Component Replacement
Wear-out faults are related to endurance period and service life. The endurance period largely depends on the working conditions.
1. For example, service life of relay is determined by the roughness of the contact surface.
Contact current and load inductance are the major factors affecting its service life.
2. Capacitor inside the inverter is used mainly as a smoothing filter. Due to the chemical reaction that takes place internally, its service life is greatly affected by the temperature. Generally speaking, rising of 10°C in temperature reduces the service life of an aluminum electrolytic capacitor by half, which also affects the service life of inverter.
When the inverter is used under high temperature, the aluminum electrolytic capacitor may suffer from wear-out faults prior to other components in normal status and must be replaced to extend the service life of inverter.
Component Name
Standard replacement interval (year)
Method of replacement/Others
5 years Cooling fan
Smoothing capacitor
Relays
5 years
―
Replace with a new one
Investigate and replace with a new one if necessary.
Investigate and replace with a new one if necessary.
◆ Contact us for replacing or repairing the components.
87
6. Maintenance and Inspection
6.5 Maintenance and Inspection Table
Note: Symbols used in “Inspection interval” are with different meanings: ☆ for
“daily”, ○ for “yearly” and ◎ for “every two years”.
Location
Inspection item
Inspection details
Ambient environment
Check the ambient temperature, humidity, dust level and etc.
Whole unit
Main
Circuit
Inspection
☆ interval
Whole unit
Power supply voltage
Check for abnormal vibration and noise.
☆
Check the main correct.
☆
1) Check if fasteners are loose;
The whole part
2) Check if there is any sign of component overheating;
3) Cleaning
○
○
○
Connected conductors and wires
1) Check if conductors are crooked;
2) Check if the wire insulation is broken
○
○
Inspection method
Refer to the
“Precautions on installation”
Check visually and listen
Measure input voltage visually.
Judgment criteria
Ambient temperature
In normal state
400V type:
323 to 506 VAC state
& humidity: -10 ~
50℃, 90%
1) Strengthen the fasteners;
2) Check visually.
1), 2): In normal state
Instrument
Thermometer
Hygrometer
Multimeter
Transformer burning smell.
Terminal block
Check if there is sign of damage.
Transistors and diodes
Smoothing capacitor
Relay
1) Check for liquid leakage;
2) Check if the safety valve is working correctly;
3) Measure electrostatic capacity.
1) Check if the operation sound is normal;
2) Check the contact roughness.
☆
☆
○
○
○
○
Just smell
Check visually.
In normal state
In normal state
Check the resistance between the terminals.
◎
Disconnect the main circuit wires and measure at the terminals.
Multimeter
1), 2): Check visually.
3): Measure with a capacitance meter
1) Just listen
2) Check visually.
1), 2): In normal state
3): Minimum 85% of rated capacity
1), 2): In normal state
Capacitance meter
88
6. Maintenance and Inspection
Location
Control circuit and protection circuit
Cooling system
Display
Inspection item
Resistor
Operation
Check
Whole unit
Capacitor
Cooling fan
Display unit
Meter
Inspection details
1) Check if there is cracking on the insulation;
2) Check if open circuit exists.
Inspection interval
○
○
Inspection method
1), 2): Check visually.
1) Check the balance condition of the output voltage between each phase during operation of single unit;
2) Inspect the protection and display circuit with timing protection operation test.
○
○
1) Measure the voltage between output terminals
2) Simulate a short circuit condition between the inverter alarm outputs.
1) Check if there is burning smell and discoloration.
2) Check if there is heavy rustling.
Check for liquid
☆ deformation.
○
○
1) Check for abnormal vibration and noise;
2) Check if connected parts are loose.
☆
Check if the indicator ☆ malfunctions.
○
1), 2): Smell and check visually.
Check visually.
1) Just listen; 2)
Strengthen the fasteners.
Check visually.
Judgment criteria
1), 2): In normal state
1) Line output balance is 8V max.
2) Timing protection circuit must function properly.
1), 2): In normal state
In normal state
1), 2): In normal state
In normal state
Instrument
Check if the indication is correct.
☆
Check the indication.
Within specifications or control values.
Voltmeter
Ammeter
1) Check for unit and noise;
2) Check if there is burning smell.
☆
☆
Check visually, listen and smell
1), 2): In normal state
89
6. Maintenance and Inspection
90
7
Specifications
7.1 Rated Specifications ······································· 92
7.2 Standard Specifications ·································· 94
7.3 Common Specifications ·································· 95
91
7. Specifications
7.1 Rated Specifications
■ 3-phase 400V Input Type
Model AMK3004
Applicable motor output (kW) *1
Standard specifications
Rated output current (A) *2
Rated output capacity (kVA) *3
Rated input current (A) *4
Power supply capacity (kVA) *4
Light load specifications
Applicable motor output(kW) *1
Rated output current(A) *2
Rated output capacity(kVA) *3
Rated input current (A) *4
Power supply capacity(kVA) *4
0P7
0.75
2.6
2.1
3.9
3.1
1P5
1.5
4.0
3.2
6.0
4.8
2P2
2.2
6.0
4.8
9.0
7.2
3P7
3.7
9.5
7.6
14.3
11.4
1.5
3.6
2.2
5.4
3.7
6.9
5.5
11.1
2.9
5.4
4.3
4.3
8.1
6.5
5.5
10.4
8.2
8.8
16.7
13.3
1.5 1.6 1.9 2.0
*1 The applicable motor here means the 4-pole standard motor at its maximum applicable capacity.
Make sure that the rated output current of the inverter is higher than the rated current of the motor at the time when selecting a model.
*2 The rated output current varies depending on the set carrier frequency.
Note to reduce the output current before its use.
*3 The rated output capacity here means the capacity when using the
3-phase 400V input type with a output voltage of 460 VAC.
*4 The input current and the power supply capacity varies with the impedance at its side. Prepare the power supply source with specifications higher than the listed values.
92
7. Specifications
■ Table 1: Relationship between Carrier Frequency and Rated Current
5.0kHz 以下 7.5kHz 10.0kHz 12.5kHz
Unit: A
15kHz
Model
Light load
Heavy load
Light load
Heavy load
Light load
Heavy
load
Light
load
Heavy
load
Light load
Heavy load
AMK3003P74 11.1 9.5 9.5 9.5 8.1 8.1 6.7 6.7 5.2 5.2
The rated output current varies depending on the set carrier frequency.
Reduce the output current according to Table 1, Figure 1 and Figure 2 before its use.
93
7. Specifications
7.2 Standard Specifications
■3-phase 400V Input Type
Items Specifications
Standard output of applicable motor (kW)
0.75~3.7 kW
Rated voltage 3-phase, 380 to 460V AC (proportional to power supply voltage)
Rated
Heavy load specifications: 150% of rated output current for 1 output Overload current rating Light load specifications: 120% of rated output current for 1 minute
Number of phases, voltage and frequency
3-phase, 380 to 460VAC, 50/60Hz
Input power supply
Allowable voltage fluctuation
Allowable frequency fluctuation
Instantaneous voltage drop ride-through capability
+ 10% and -15% of ratted input AC voltage
±5% of rated input frequency
·Operation continues when voltage is above 323VAC.
·Operation continues for 15ms when voltage drops below
323VAC.
94
7. Specifications
7.3 Common Specifications
Input Power
Supply
Applicable motor capacity
(kW)
Model
0.75 AMK3000P74
3-phase
400V
1.5 AMK3001P54
2.2 AMK3002P24
3.7 AMK3003P74
Items Specifications
Output frequency
Frequency range
Frequency display
Frequency accuracy
Frequency resolution
Inverter control mode
Carrier frequency
Run/Stop
Operation
Forward/Reverse run
JOG operation
Stop mode
Reset function
VF control: 0.2 to 400Hz
Sensorless vector control: 0.5 to 120 Hz
Digital display
Analog setting: within ±0.5% of maximum setting frequency (25°C±10°C)
Digital setting: within ±0.01% of maximum setting frequency (-10°C to +50°C)
Analog setting: 0.1Hz (in 50/60Hz mode)
Digital setting: 0.1Hz
High carrier frequency sinusoidal PWM control
(V/F control or sensorless vector control is available.)
·V/F control setting: 9 options can be selected
(adjustable from 0.8 to 15 kHz).
·Sensorless vector control: 6 options can be selected
(adjustable from 2.5 to 15 kHz)
(0.8, 1.1, 1.6, 2.5, 5.0, 7.5, 10.0, 12.5, 15.0kHz)
• Operation panel buttons
• 1a contact signal and 3-wire input (1a and 1b contact signals) can be selected.
• RS485 communication
• Wait time (0.1 to 100 s) can be set.
• Operation panel buttons
• 1a contact signal (reverse run can be disabled.)
• RS485 communication
Operation frequency: adjustable from 0.2 to 400 Hz
Acceleration/deceleration time: adjustable from 0.04 to
3600s
Ramp-to-stop / coast-to-stop (switchable)
Stop signal reset/external reset/panel reset (optional)
/power supply reset
95
7. Specifications
Items
Start frequency
Stop frequency
Specifications
Adjustable from 0.2 to 60Hz
Adjustable from 0.2 to 60Hz
Operation
Control
Control
Speed search
Retry function
Frequency setting signal
Voltage/frequency characteristics
Speed search during startup (optional)
Retry select: validity of function, details of retry faults
Retry times: adjustable from 1 to 10 times
Panel setting (operation panel): digital setting
Analog setting signal input from external control:
• Potentiometer (10 kΩ, 1/4 W or higher)
• 0 to 5 VDC, 0 to 10 VDC
• 4 to 20 mA, 0 to 20 mA
Digital setting signal input from external control:
• PWM signal (cycle: 1 to 2000 ms) or Pulse input signal
• Frequency rise SW/drop SW/storage SW signal
Communication setting: RS485
Base frequency: fixed at 50/60 Hz, adjustable from 45 to
400Hz
In 3-point V/F mode: adjustable voltage and frequency
V/F curve: constant/square torque mode (switchable)
Adjustable from 0 to 40%/auto torque boost (switchable) Torque boost
Acceleration/deceleration time
Acceleration/deceleration characteristics
The 2 nd function select
0.04 to 3600s (independent acceleration/deceleration setting)
Linear and S-shaped acceleration/deceleration
(switchable)
The 2 nd function select (acceleration/deceleration time, torque boost, voltage/frequency characteristics (base frequency, 3-point V/F mode, electronic thermal and analog frequency setting)
Multi-speed frequency setting
•Multi-speed operation: up to 16 speed settings (No limitation to frequency setting)
•Timer operation: up to 8 speed settings (No limitation to frequency setting)
It can be linked with acceleration/ deceleration time.
Skip frequency setting
Up to 3 settings (skip frequency band adjustable from 1 to
10 Hz)
Upper frequency limit setting
Adjustable from 0.2 to 400Hz
Lower frequency limit setting
Adjustable from 0.2 to 400Hz
Bias/gain frequency setting
Bias frequency: adjustable from -99.0 to 250.0%
Gain frequency: adjustable from 0.0 to 500.0%
96
7. Specifications
Items
External stop function
Specifications
External fault stop/coast-to-stop (switchable)
PID function PID control mode (optional)
Braking
Output signal
Display
Offline auto-tuning function Auto-tuning of motor constant
Cooling fan ON/OFF control
Optional
Communication function
·Interface: RS485 serial communication
·Communication speed: 4800/9600/19200/38400/57600/
115200 bps (switchable)
·Protocols: MEWTOCOL-COM/Modbus-RTU/
Modbus-ASCII (switchable)
·Communication pattern: Half duplex
·Maximum number of connected units: 31
·Maximum transmission distance: 500m (in total)
Regenerative braking torque
·400V, 0.75 to 3.7kW: 20% or higher
DC braking
Analog output
Open-collector output
Relay output
Operation/control status
Details of abnormality
Operate at the frequency below stop frequency
•Braking torque level: 0 to 100
•Braking time: adjustable from 0.1 to 120 s
Output specifications: 0 to 10 VDC(max. 1mA)
Output function: output frequency and output current proportion (switchable)
Output specification: max. rating 50 VDC/50 mA
Output functions: operation signal, arrival signal, overload alarm, frequency detection, abnormal reverse run signal alarm, current detection, timer OFF signal, output frequency/current proportion PWM signal and output frequency/current proportion pulse signal (switchable)
Output Specifications: 1c contact (contact capacity
230VAC, 0.3A; 30VDC, 0.3A resistive load)
Output functions: operation signal, arrival signal, overload alarm, frequency detection, abnormal reverse run signal alarm, current detection, timer OFF signal (switchable)
Output frequency, linear speed display (switchable) and rotation direction
Output voltage, internal DC voltage, setting frequency, communication station No., operation times of timer, alarm type, control circuit terminal status (I/O signal), operation status, PID (setting value, measured value and output value), progress of automatic tuning, accumulative operation time and accumulative operation time of fan
Specific symbol is indicated when the protection function is activated (the latest four abnormalities are stored.)
97
7. Specifications
Protection
Environment
Items Specifications
Current limit
Trip (stop)
Current limit can be set within 1 to 200% of rated output current.
Instantaneous overcurrent (SC1-6) and abnormal temperature (OH)
Overcurrent (OC1-3), overload and electronic thermal relay (OL), undervoltage (LU), overvoltage (OU1-3), cooling fan fault (FAn), external fault (AU), operation fault
(OP) and CPU fault (CPU, ErrC)
Overcurrent and overvoltage stall prevention Stall prevention function
Ambient temperature and humidity
-10 to +50°C (Note 1) (without freezing) and below
90%RH (without condensation)
Storage temperature and humidity
-25 to +65°C and below 95%RH
Altitude
Location
1000m or below
Indoor areas free of corrosive gases, flammable gases, oil mist or dust
Cooling method 0.75kW: self-cooling; 1.5to 3.7kW: air-cooling
Note 1: It is -10 to +40°C when multiple inverters are installed side-by-side.
98
Appendix
Function Parameter List
99
Appendix Function Parameter List
P001
The 1st Acceleration Time
The time to accelerate from 0.2 Hz to the maximum output frequency can be set.
Data setting range (s) 0.04·0.1~3600
Increment (s)
0.1(0.1~999.9)、
1(1000~3600)
· The display code for “0.04 s” is “0.0”.
· The maximum output frequency can be set with parameter P009 and P012.
· Please note that if the acceleration time setting is too small, overcurrent may occur depending on the load.
Related parameters: P009, P012
100
Appendix Function Parameter List
P002
The 1st Deceleration Time
The time to decelerate from the maximum to 0.2 Hz output frequency can be set.
Data setting range (s) 0.04·0.1 ~ 3600
Increment (s)
0.1(0.1 ~ 999.9)、
1(1000 ~ 3600)
· The display code for “0.04 s” is “0.0”.
· The maximum output frequency can be set with parameter P009 and P012.
· Please note that if the deceleration time setting is too small, overcurrent may occur depending on the load.
Related parameters: P009, P012
101
Appendix Function Parameter List
P003
Run Command Selection
Run/stop and forward/reverse run can be selected via the operation panel, the signal input from external control device or the communication commands.
Setting value
Command status
Panel reset function
Operation method and control circuit terminal connection diagram
RUN : RUN, STOP : STOP
Enabled / (Forward/reverse): can be set in the Rotation
Direction Setting mode (dr mode)
+
RUN
: Forward Run,
Enabled
STOP
: STOP
+
RUN
: Reverse Run,
Commom terminal
(Terminal No.⑦)
ON: Run /OFF: Stop
ON: Reverse /OFF: Forward
Commom terminal
(Terminal No.⑦)
ON: Forward run/OFF: Stop
ON: Reverse run/OFF: Stop
Disabled Make run command transmitted through communication valid.
■ Panel Reset Function
After an abnormal tripping, if the stop signal from external operation cannot reset it, use the
STOP
button on the operation panel to make a reset. However, if the reset lock function is enabled, the reset lock function shall take precedence, yet the reset function is also valid.
(*1): Set the “SW1~6”Function Selection of parameters P101
~
P106 to the setting values of “16(r16): Run/Stop” and “17(r17): Forward/Reverse”.
102
Appendix Function Parameter List
■ 3-wire run/stop command
Please assign the “3-wire stop command” to any one of the input terminals of
SW1 to SW6.
Setting value
Command status
Panel reset function
Operation method and control circuit terminal connection diagram
2
3
External control
External control
Disabled
Enabled
Commom terminal
(Terminal No.⑦)
ON: Run
ON: Reverse/OFF: Forward
ON: Stop (*1)
4
5
External control
External control
Disabled
Enabled
Commom terminal
(Terminal No.⑦)
ON: Forward run
ON: Reverse run
ON: Stop (*1)
(*1) Set the “SW1~6”Function Selection of parameters P101 to P106 to the setting values of “16(r16): Run/Stop” and “17(r17): Forward/Reverse”.
(*2) If any terminal of SW1 to SW6 is used as “3-wire stop command”, please set their corresponding parameters P101 to P106 to “11 or r11”
(*3) When 3-wire mode is used, “a” contact input shall apply.
(*4) When 3-wire mode is used, “b” contact input shall apply.
When P003 is set to “2 or 3”. When P003 is set to “4 or 5”.
Forward
Forward
Time
Time
Reverse
SW1
(P101 = 16)
SW2
(P102 = 17)
SW3
(P103 = 11)
ON
ON
ON
Reverse
SW1
(P101 = 16)
SW2
(P102 = 17)
SW3
(P103 = 11)
ON
ON
ON
OFF
ON
OFF
ON
ON
OFF
ON
OFF
ON
· The operation status will not change if the forward run and reverse run signals are both “ON”. But if it is in a stop mode, it will not operate even if the signals are both ON.
Related parameters: P101 to P106
103
Appendix Function Parameter List
P004
Frequency Setting Signal
The frequency setting signal can be set via the operation panel, the signal input from external devices or the communication command.
Setting value
0
Command status
Panel
1
2
3
4
5
External control
Panel reset function
Operation method and control circuit terminal connection diagram
Digital setting Can be set in the “Frequency Setting Mode (Fr)”
Potentiometer
VR input
0~5V
(Voltage signal)
0 ~10V
(Voltage signal)
4~20mA
(Current signal)
0~20mA
(Current signal)
Terminal AK, AL and AN, (center of potentiometer is connected to Terminal AL).
Terminals AL and AN (12: +, 14: -)
Terminals AL and AN (12: +, 14: -)
Terminals AL and AN (12: +, 14: -)
Terminals AL and AN (12:+, 14:-)
Enable the frequency command transmitted via communication.
7 PWM signal input Terminal No. 6 and No. 7 (6: +, 7: -)
External control
8 Pulse input Terminal No. 6 and No. 7 (6: +, 7: -)
· When the setting value is set to “1” to “5”, the inverter will run or stop as defined by the setting value of “P047: 0V Stop Function Selection”. If 0V Stop
Function is set to invalid, parameter P047 should be set to “0.0”.
Related parameters: P009, P012, P047, P109 to P113
104
Appendix Function Parameter List
P005
Operation Status Monitoring
The display on the panel can be changed according to its purpose.
Setting value
Function Name
LED display
Operation
Preparation Status
(in Stop mode)
Operation Status
3 Communication station No.
5
6
7
8
* The display example shown in the above Table, where the operation frequency is “50.0” , the output current is “1.0A”, the setting frequency is “50.0”, the communication station No. is
“01”, the linear speed multiplier is “0.5”, and the winding length is “10.00”.
Communication station
No./Output frequency
Communication station
No./Linear speed
Communication station No./
Output current
Winding length (the same as n022)
· When in the Operation Status Display mode, press the current display.
button to switch to
· The operation preparation status recorded in this Manual is “0000”, the display will change based on the setting value when this parameter is changed.
Related parameters: P054
105
Appendix Function Parameter List
P006
Vector Control Selection
This function is effective for the case that the load fluctuates sharply when high start-up torque or sufficient torque at lower speed is required. But it is not applicable to the load whose minor rotation may cause problems at lower speed.
Setting value
Details
If it is set to the vector control mode, please carefully read “4.15: Vector
Control” and follow the precautions to set various parameters.
P007
Carrier Frequency
To reduce the motor noise and avoid the machine resonance, you may change the carrier frequency.
■ “P006: Vector Control Selection” is set to “0” (when V/F control is selected)
Setting value (kHz) 0.8, 1.1, 1.6, 2.5, 5.0, 7.5, 10.0, 12.5, 15.0 (9 values are optional)
■ “P006: Vector Control Selection” is set to “1” (when sensorless V/F control is selected)
Setting value (kHz) 2.5, 5.0, 7.5, 10.0, 12.5, 15.0 (6 values are optional)
· Please carefully read “Chapter 7: Relationship between Carrier Frequency and Rated Current” before you change the carrier frequency.
106
Appendix Function Parameter List
P008
S-shape Acceleration/Deceleration Mode
The acceleration/deceleration mode can be switched between linear and
S-shaped (quadratic and cubic) pattern.
Setting value
0
1
2
Details
Linear acceleration/deceleration (Factory setting)
S-shaped acceleration/deceleration
(Quadratic curve)
S-shaped acceleration/deceleration
(Cubic curve)
· The acceleration/deceleration time remains the same regardless of the acceleration/deceleration mode (linear or s-shaped acceleration/deceleration).
Related parameters: P001, P002, P317 to P322
107
Appendix Function Parameter List
P009
V/F Control
V/F mode of “50· 60 Hz” and “0.2 to 400 Hz” can be set separately within the maximum output frequency band (50 ~ 400 Hz).
Setting value
Name Details
V/F mode of 50 Hz is set regardless of parameter P012 and
P013 setting.
V/F mode of 60 Hz is set regardless of parameter P012 and
P013 setting.
V/F mode can be set via parameter P012 and P013. Set the maximum output frequency via parameter P012 and the base frequency via parameter P013.
3-point V/F mode can be set via parameter P012 to P017.
Set the maximum output frequency via parameter P012 and the base frequency via parameter P013.
Set the change point frequency 1 via parameter P014 and the change point voltage 1 via parameter P015.
Set the change point frequency 2 via parameter P016 and the change point voltage 2 via parameter P017.
3C1 3-point fixed mode 1 Set value for the fixed mode via parameter P013 to P017.
3C2 3-point fixed mode 2 Set value for the fixed mode via parameter P013 to P017.
3C3 3-point fixed mode 3 Set value for the fixed mode via parameter P013 to P017.
3C4 3-point fixed mode 4 Set value for the fixed mode via parameter P013 to P017.
3C5 3-point fixed mode 5 Set value for the fixed mode via parameter P013 to P017.
3C6 3-point fixed mode 6 Set value for the fixed mode via parameter P013 to P017.
108
Appendix Function Parameter List
If 3-point V/F mode is used, please set each parameter according to the following diagram.
(Also apply to the 2nd characteristic).
109
Appendix Function Parameter List
· Settings for 3C1 to 3C6 will not affect the 2nd characteristics.
· Factory settings of maximum output frequency and base frequency are both
50Hz.
· Please consider the setting of Upper Frequency Limit (parameter P046) when changing the maximum output frequency.
· In free mode or 3-point mode, please note that sharp acceleration/deceleration or overcurrent may occur depending on setting values and load state if change point frequency and voltage are changed during operation.
· If change point frequency 1 or 2 is set to a value higher than the base frequency, the invert will still operate according to the base frequency setting.
· If change point frequency 2 is set to a value lower than change point frequency 1, it will operate according to the setting of the latter one.
· If change point voltage 1 or 2 is set below the torque boost value, it will operate according to the setting value of “P011: Torque Boost”.
· If change point voltage 2 is set to a value lower than change point voltage 1, it will operate according to the setting of the latter one.
· In 3-point mode, V/F curve (P010) corresponds to constant torque mode. Even if the setting is square torque mode, constant torque mode still applies.
· It is invalid during vector control (P006 = “1”).
Related parameters: P011 to P017, P046
110
Appendix Function Parameter List
P010
V/F Curve
Constant or square torque mode can be selected.
Setting value
0
1
Name
Constant torque mode
Square torque mode
Remarks
For machine applications, etc.
For fan and pump applications, etc.
· If “P009: V/F Mode” is set to “3C”, “3C1 to 3C6”, V/F curve will correspond to constant torque mode.
Even if the setting is square torque mode, constant torque mode will still apply.
· It is invalid during vector control (P006 = “1”).
Related parameters: P009, P013
111
Appendix Function Parameter List
P011
Torque Boost
Torque boost level corresponding to load characteristics can be set. The larger the setting value is, the higher output voltage and torque boost will be.
· After the mode is set to “auto torque boost”, the output voltage will change automatically according to the load fluctuation. To set “Auto torque boost”, please clockwiswly rotate once when the operation panel displays “40”.
Name
Auto torque boost
Manual torque boost
Data setting range
(%)
Auto
0~40%
Method of increasing torque at lower speed
· If higher torque is required at lower speed, the torque boost level can be set to a larger value, thus generating higher output voltage to increase the torque.
· If the boost level setting is too high, it may cuase overcurrent fault, overload fault, motor overheating or excessive noise.
· The motor current will rise after the boost level increases. Please carefully consider the settings for “P023: Electronic Thermal Selection” and “P024:
Thermal Current Setting”.
· Once it is set to “vector control”, the settings for parameter “P006: Vector
Control Selection =1” and parameter “P011: Torque Boost” will become invalid.
· If auto torque boost mode is selected, be sure to conduct auto-tuning and use the inverter with correct setting of the motor constants.
(Please carefully read “4.14: auto-tuning” for the details of auto-tuning.)
112
Appendix Function Parameter List
P012
P013
Max. Output Frequency
Base Frequency
Maximum output frequency and base frequency can be set.
(Parameter P009 is only valid when “FF” or “3C” is set.)
■ Parameter P012: Max. Output Frequency
Data setting range (Hz) 50.0~400.0
■ Parameter P013: Base Frequency
Data setting range (Hz) 45.0~400.0
· If “P009: V/F Mode” is set to “50”, “60” or “3C1 to 3C6”, the maximum output frequency and base frequency will be fixed values.
· A frequency higher than “P046: Upper Frequency Limit” cannot be output.
· If a general-purpose motor with rated frequency of 50/60 Hz is running at a frequency exceeding the ratings, the motor may be damaged. Therefore, please set a frequency that matches with the motor characteristics.
· If base frequency is required to be changed simutaneously with maximum output frequency for a dedicated high-speed motor etc., such change should also be made via this parameter.
· When running a general-purpose motor at a frequency higher than universal frequency, the base frequency setting should not exceed the rated output frequency (50/60 Hz) of the motor.
· When a general-purpose motor reaches a level higher than the base frequency (normally 50/60 Hz), the motor will show constant output characteristics and the generated torque will drop in reverse proportion to the frequency.
· If “P006: Vector Control Selection” is set to “Sensorless Vector Control” mode, the maximum output frequency shall range from 50.0 to 120.0Hz.
Related parameters: P009, P046
113
Appendix Function Parameter List
P014
P015
Change Point Frequency 1
Change Point Voltage 1
P016
P017
Change Point Frequency 2
Change Point Voltage 2
Change point 1 and 2 can be selected in 3C mode of “P009: V/F Mode”.
(It is only valid when parameter P009 is set to “3C”.)
■ ParameterP014:Change Point Frequency 1
Data setting range (Hz) 0.2~400.0
■ ParameterP015:Change Point Voltage1
Data setting range (%) 0.0~100.0
■ ParameterP016:Change Point Frequency 2
Data setting range (Hz) 0.2~400.0
■ ParameterP017:Change Point Voltage 2
Data setting range (%) 0.0~100.0
· Read “P009: V/F Mode” carefully before setting.
· Change point frequency 1 and 2 will operate according to the setting value of the base frequency when set to a value higher than the base frequency.
· Change point frequency 2 will operate according to the setting value of change point frequency 1 when set to a value lower than change point frequency 1.
· When setting “P011: Torque Boost”, change point voltage 1 and 2 will operate according to the setting value of torque boost if set to a value lower than torque boost level.
· Change point voltage 2 will operate according to the setting value of change point voltage 1 when it is set to below change point voltage 1.
· Please note that sharp acceleration/deceleration or overcurrent may occur depending on setting values and load status if data is changed during operation.
· When "3C1" to "3C6" of "P009: V/F Mode" is set, P010 to P013 will change to fixed value automatically, and cannot be changed.
Related parameters: P009, P046, P011 to P013
114
Appendix Function Parameter List
P018
Max. Output Voltage
The msximum output voltage can be set via this parameter.
Data setting range (V) 1~500
*When the data is set to “0”, power voltage value will be output
· A voltage exceeding power supply rating cannot be output.
· This setting has no connection with the DC brake level.
· It is invalid when vector control mode is selected.
Related parameters: P009, P012
115
Appendix Function Parameter List
P019
P020
P021
P022
JOG Frequency
JOG Acceleration
JOG Deceleration
JOG Panel Operation
The operating frequency, acceleration/deceleration time during JOG operation can be respectively set via these parameters.
■ Parameter P019: JOG Frequency
Data setting range (Hz) 0.2~400.0
■ Parameter P020: JOG Acceleration
Data setting range (s) 0.04·0.1~600
Increment (s) 0.1(0.1~999.9), 1(1000~3600)
· The display code for 0.04 is “0.0”.
■ Parameter P021: JOG Deceleration
Data setting range (s) 0.04·0.1~3600
Increment (s) 0.1(0.1~999.9), 1(1000~3600)
· The display code for 0.04 is “0.0”.
■ Parameter P022: JOG Panel Operation
Name
Panel JOG
Operation
Setting value
0
1
2
Details
Panel JOG function is invalid.
Use Panel JOG function (JOG function of the external device is invalid)
Panel JOG function (JOG function of the external device is invalid)
116
Appendix Function Parameter List
Operation Method of Panel JOG Function
① Power on the inverter.
The inverter displays “
0000
” when the power is ON.
②
Press mode.
MODE
button to enter into the Parameter Setting
③ Rotate the knob to “P0: Parameter Setting”.
MODE
④ Press the knob to display parameter P001.
⑤
Rotate the knob to “P022: JOG Panel Operation”.
⑥
Press the knob to proceed to the setting of value for P022.
⑦
Rotate the knob to adjust the value of P022 to “1”.
⑧ Press the knob to apply the setting “1” for P022 and use the Panel JOG function. (adopt the same method to respectively set P019 to “ 10.0
”, P020 to “ 5.0
” and
P021 to “5.0” ).
⑨ Press
MODE
button to enter into Forward JOG operation and display “ Jog.F
” .
( Counterclockwisely rotate the knob to switch to Reverse
JOG operation to display “ Jog.r
”)
⑩
Press RUN button to forward accelerate the motor to
10.0Hz and remain at this speed.Loosen
Loosen
RUN
button, the motor will decelerate until it stops.
RUN
· Where the external control JOG function is selected, the operation command must be set to External Control operation (Parameter P003 shall be set to
“2” to “5”).
· Where the external control JOG function is selected, please refer to the related contents of parameters P101 to P106.
· The JOG frequency used in vector control ranges from 0.5Hz to 120.0Hz.
Related parameters: P003, P101 to P106
117
Appendix Function Parameter List
P023
P024
Electronic Thermal Selection
Thermal Current Setting
Electronic thermal operation level can be set when motor overload is detected and the inverter output needs to be stopped.
Operation coasts to stop when OL is displayed.
■ Parameter P023: Electronic Thermal Selection
Setting value
Validity of function
Details of function
1
2
3
Enabled The output frequency is not derated.
Enabled The output frequency is derated.
Enabled Forced air-cooled motor specification
* About frequency derating
The function can automatically compensate operation level when motor cooling performance drops during low-speed operation.
■ Parameter P024:Thermal Current Setting
Data setting range (A) 0.1~100.0
* Please make settings according to the rated current of the applicable motor.
■ Example of setting current and thermal operation (P023=1)
· Setting current×100% Does not operate
· Setting current×125% Operate (OL trip)
118
Appendix Function Parameter List
P025
Overcurrent Stall Prevention Function
· Overcurrent Stall Prevention Function:
During acceleration/deceleration, if acceleration/deceleration time is too short for the inertial load and the output current exceeds OCS level, the parameter serves to extend acceleration/deceleration time.
· Overcurrent Trip Prevention Function:
If overcurrent occurs in the inverter during operation, output will be temporarily stopped and started again when the current drops to normal level.
Name Setting value
Overcurrent
Stall
Prevention
Function
0
1
2
3
Details
Overcurrent Stall Prevention Function: OFF
Overcurrent Trip Prevention Function: OFF
Overcurrent Stall Prevention Function: ON
Overcurrent Trip Prevention Function: ON
Overcurrent Stall Prevention Function: OFF
Overcurrent Trip Prevention Function: ON
Overcurrent Stall Prevention Function: ON
Overcurrent Trip Prevention Function: OFF
· When load fluctuates drastically or the inverter accelerates or decelerates sharply, instantaneous overcurrent may sometimes lead to a trip.
· The operation level of overcurrent stall prevention function can be set via parameter “P028: OCS Level”. The factory setting is 140% of the rated current.
· Overcurrent trip prevention function is activated regardless of the setting of parameter “P025: Overcurrent Stall Prevention Function” after parameter
“P027: Current Limit Function” is set.
· Overcurrent trip prevention function shall be disabled if the sensorless vector control function is selected.
Related parameters: P028
119
Appendix Function Parameter List
P026
Overvoltage Stall Prevention Function
During deceleration, when the deceleration time is too short for the inertial load, this parameter can be used to temporarily retard the deceleration, thus preventing overvoltage trip.
Setting value
0
1
Details
Stall prevention function disabled
Stall prevention function enabled
· When regenerative brake is used in the inverter with braking function, please set the value to “0”.
(The regenerative brake function will be disabled if the factory setting is “1”).
· The specifications of the built-in brake of the inverter are as follows. Please take them into full consideration before its use.
Please note that the braking resistor and inverter could be damaged if used beyond specifications.
(3) Maximum working time: 5s
· Only brake circuit is built in the inverter.
(1) Braking torque: 100%
(2) Maximum duty factor (%ED): 5%
120
Appendix Function Parameter List
P027
Current Limit Function
If the output current reaches the overcurrent stall level (OCS level) during overload operation, the frequency will be automatically reduced. When the load recovers to normal level, the frequency will be automatically restored to the original setting and the operation will continue. This function is effective for preventing overcurrent trips in sticky material crushing machines.
When the function becomes valid/invalid and the output current reaches the overcurrent stall level, deceleration time will be automatically set to lower the frequency.
The operation level (overcurrent stall level) can be set with the parameter
“P028: OCS Level”.
Data setting range (s) 0.0·0.1~9.9
* “0.0” corresponds to a setting without current limit.
· Overcurrent trip prevention function is activated regardless of the setting of parameter “P025: Overcurrent Stall Prevention Function” after parameter
“P027: Current Limit Function” is set.
Related parameters: P025, P028
121
Appendix Function Parameter List
P028
OCS Level
The OCS level (overcurrent stall prevention operation level) and current limit function level can be set with a ratio (%) to the rated current of inverter.
Data setting range (%) 1~200
· The factory setting of OCS level is 140 % of the rated current.
· The OCS level is equivalent to the current limit level.
· It has no connection with the electronic thermal level and the overload detection level.
Related parameters: P025, P027
122
Appendix Function Parameter List
P029
P030
Retry Function Selection
Retry Count
The retry function can automatically reset the fault and restart (run) operation after waiting time has elapsed when an inverter fault trip occurs. Please use this function to continue the operation.
When the retry function is used, the unit may automatically start (restart) suddenly, so do not approach the unit. (Please take measures to ensure personal safety.)
Failure to do so may lead to injury.
■ Parameter P029: Retry Function Selection
Setting value
0
Details
Retry function disabled (retry is not performed.)
1
2
Perform retry operation only for overcurrent fault and heat sink abnormal overheating (OC1/OC2/OC3).
Perform retry operation only for overvoltage fault (OU1/OU2/OU3).
3
Perform retry operation only for overcurrent fault and heat sink abnormal overheating (OC1/OC2/OC3) and overvoltage fault (OU1/OU2/OU3)
■ Parameter P030: Retry Count
Data Setting Range (times) 1~10
123
Appendix Function Parameter List
· The retry interval is set via the parameter “P033: Waiting Time”.
· Fault alarm is not output during retry operation. But when the fault still occurs even if retry is performed for preset times, the fault alarm will be output.
· If an unselected fault occurs during retry, the fault alarm will be output and the retry count accumulated up to now will be cleared.
· Once the power is cut off, the retry count accumulated up to now will be cleared.
· If the fault does not occur for over 5 minutes, the retry times accumulated up to now will be cleared.
· When speed search is selected via parameter “P361: Speed Search
Selection during Retry” and the time set via parameter “P033: Waiting Time” and “P359: Waiting Time to Speed Search” has elapsed, the speed search function will start to operate.
Related parameters: P033
P031
Start Mode
This parameter is used to set the start-up operation for the case that a run signal set externally is input when the power is turned ON.
Depending on the start mode setting, when the run signal is
ON, the inverter may start (restart) suddenly if the power is turned ON or restored after a power failure. Therefore, do not approach the unit. Design the machine so that personal safety can be ensured even if the inverter starts suddenly.
Depending on the start mode function setting, if the fault trip is reset with the run signal ON, the inverter may sometimes restart suddenly. (Please take measures to ensure personal safety.)
Failure to do so may lead to injury.
· The factory setting is "1" (OP stop).
· If the value is set to “0”, operation will start immediately after the power is turned ON.
· If the value is set to "2", operation will start when the power is turned ON and after the waiting time has elapsed.
124
Appendix Function Parameter List
Setting value
Operation
0 Run
Details of operation
Operation starts immediately when the low voltage level (LU level) is exceeded after the power is turned ON.
OP trip occurs when the low voltage level (LU level) is exceeded after the power is turned ON.
Turn the run signal OFF once, perform reset operation and turn the run signal ON again to start operation.
2 elapes turned ON.(The waiting time can be set via parameter P033.)
OP trip occurs when the low voltage level (LU level) is exceeded after the power is turned ON. Turn the run signal
OFF once, perform reset operation and turn the run signal ON again to start operation.
(The setting will function in the same manner as data "1" with run signal ON when the power is turned ON. However, starting after the waiting time has elapsed is possible during normal startup.)
· Waiting time can be set via parameter P033.
Related parameters: P033
125
Appendix Function Parameter List
P032
Ride-through Restart Selection
The restart pattern after constant power failure or instantaneous power supply can be selected according to the load status and system configuration.
A waiting timer function is built-in.
The inverter may suddenly start (restart) if the power is restored after a power failure with the setting of ride-through restart, so do not approach the unit.
Please take measures to ensure personal safety. Failure to do so may result in injury.
Setting value
0
1
2
3
Function
Name
Restart
Mode 1
Restart
Mode 2
Restart
Mode 3
Restart
Mode 4
Inverter operation in regard to instantaneous power failure time
≥ 15 ms
(Note 1)
Operation continues
≥ 15 ms
(Note 1)
≤ 100 ms
(Note 2)
>100 ms
(Note 2)
·LU trip occurs and the inverter operates according to the start mode setting.
·“LU” will be displayed and the fault alarm signal will be output.
·Restart from 0 Hz after the waiting time has elapsed.
·“LU” will be displayed and the fault alarm signal will not be output.
·After the waiting time has elapsed, the inverter restarts at the frequency applied before the ride-through occurrence.
·“LU” will be displayed and the fault alarm signal will be output.
The inverter operates according to the start mode
·After the waiting time has elapsed, the inverter will sense the motor rotation through speed search function and restart at the setting. corresponding frequency. (note 3)
·“LU” will be displayed and the fault alarm signal will be output.
Note 1: This is the minimum time for operation at the rated output current.
(The time may be longer depending on different models.)
Note 2: This is the minimum time. (The time may be longer with higher rated capacity.)
Even if the power failure time is relatively long (approx. 1 min.), the inverter may sometimes restart after the power is restored. Therefore, inverter, motor and load equipments should be restarted after the power is restored for more than 4 minutes (waiting time + 2 minutes).
Note 3: In sensorless vector control, speed search will not be performed and the inverter will operate according to the start frequency setting (P036).
126
Appendix Function Parameter List
· Waiting time can be set via parameter P033.
Related parameters: P033
127
Appendix Function Parameter List
P033
Waiting Time
Waiting time required by the start mode, the ride-through restart and retry function can be set.
Data setting range (s) 0.1~100.0
Related parameters: P029~P032
P034
Reverse Run Lock
When used only in forward run mode, reverse run can be disabled to avoid possible mishandling.
Setting value
0
1
Details
Reverse run operation enabled
(Both forward run and reverse run operation enabled)
Reverse run disabled
(Only forward run operation enabled)
· When disabled, reverse run cannot be performed during the operation of panel, external control and communication.
Related parameters: P004
P035
Start Frequency
The frequency at which the inverter output starts can be set during inverter start-up.
Data setting range (Hz) 0.2~60.0
· Please note that overcurrent may occur depending on setting values and load status if the data is changed during operation.
· In vector control mode, the minimum value is changed to “0.5Hz”.
128
Appendix Function Parameter List
P036
Stop Mode
Ramp-to-stop or coast-to-stop mode can be selected when stopping the inverter.
Setting value
1
Details
0 Ramp-to-stop
Details
The inverter is stopped by the stop signal depending on the frequency decreased according to the deceleration time.
Coast-to-stop The inverter output is shut off immediately by the stop signal.
P037
Stop Frequency
The frequency at which the inverter output stops can be set when the inverter ramps to stop.
Data setting range (Hz) 0.2~60.0
Related parameters: P038 to P039
129
Appendix Function Parameter List
P038
P039
DC Brake Time
DC Brake Level
DC brake can be applied when the inverter output frequency drops below “P037:
Stop Frequency” during ramp-to-stop.
In addition, positioning control can be performed combining with JOG operation.
■ Parameter P038:DC Brake Time
Data setting range (s) 0.0~120.0
* The DC brake is disabled when “0.0” is set.
■ Parameter P039:DC Brake Level
Data setting range (%) 0~100
* The larger the value is, the stronger the braking force is.
· DC brake starts at the frequency corresponding to the setting value of parameter “P037: Stop Frequency”.
· DC brake during the switching between forward run and reverse run is set via parameter “P040: Stop Frequency during Forward/Reverse Run
Operation”, “P041: DC Brake Time during Forward/Reverse Run Operation” and “P042: DC Brake Level during Forward/Reverse Run Operation”.
Related parameters: P037
130
Appendix Function Parameter List
P040
P041
P042
Stop Frequency during Forward/Reverse Run Operation
DC Brake Time during Forward/Reverse Run Operation
DC Brake Level during Forward/Reverse Run Operation
DC brake can be applied when the inverter output frequency drops below
“P040: Stop Frequency during Forward/Reverse Run Operation” during forward/reverse run operation.
■ Parameter P040:Stop Frequency during Forward/Reverse Run Operation
Data setting range (Hz) 0.2~60.0
■ Parameter P041: DC Brake Time during Forward/Reverse Run Operation
Data setting range (s) 0.0~120.0
* The DC brake is disabled when “0.0” is set.
■ Parameter P042: DC Brake Level during Forward/Reverse Run Operation
Data setting range (%) 0~100
* The larger the value is, the stronger the braking force is.
· The frequency for applying the DC brake is set by parameter “P040: Stop
Frequency during Forward/Reverse Run Operation”.
· “P040: Stop Frequency during Forward/Reverse Run Operation” is only valid when DC brake is applied during forward/reverse run operation. (It’s valid when P041 is set to a value other than “0000” )
· To stop the inverter, DC brake can be set via parameter “P037: Stop
Frequency”, “P038: DC Brake Time” and “P039: DC Brake Level”.
131
Appendix Function Parameter List
P043
P044
DC Brake Time at Start-up
DC Brake Level at Start-up
· The coast-to-stop motor can be restarted via this parameter after a pause.
■ Parameter P043: DC Brake Time at Startup
Data setting range (s) 0.0~120.0
■ Parameter P044: DC Brake Level at Startup
Data setting range (%) 0~100
*1: Set P043 to “0.0” to disable the DC brake function when not used.
*2:The larger the value is, the stronger the braking force is.
· The start frequency is specified by parameter “P035: Start Frequency”.
· Please note that sharp acceleration/deceleration or overcurrent may occur depending on the setting values and load status if data is changed during operation.
· When parameter “P357: Speed Search at Startup” is set to “enabled”, the setting value of DC brake set via this parameter is “disabled”.
132
Appendix Function Parameter List
P045
P046
Lower Frequency Limit
Upper Frequency Limit
The upper limit and lower limit of the output frequency can be set.
■ ParameterP045:Lower Frequency Limit
Data setting range (Hz) 0.2~400.0
■ ParameterP046:Upper Frequency Limit
Data setting range (Hz) 0.2~400.0
· When the upper frequency limit is lower than the maximum output frequency
(parameter P012), the upper frequency takes precedence.
· When the lower frequency limit is higher than the upper frequency limit
(reverse run setting), the latter takes precedence.
· The inverter may accelerate/decelerate depending on the setting values when data is changed during operation.
· In vector control mode, the minimum value and the maximum value shall be respectively changed to 0.5Hz and 120Hz.
Related parameters: P009, P012
133
Appendix Function Parameter List
P047
0V Stop Function Selection
When the frequency setting signal is lower than than setting value, the inverter output can be stopped by using 0V stop function.
Data setting range (Hz) 0.0·0.2~400.0
· Setting value “0.0” : 0V stop function disabled.
· Setting value “0.2~400.0” : 0V stop function enabled(0V stop function setting)
■ 0V stop function
· When the frequency signal is set to “analog setting (parameter P004 = “1”,
“2”, “3”, “4” and “5”), the inverter will stop output after the frequency setting signal reaches a value below the setting value of 0 V stop function selection.
· 0 V stop will not be performed if 0 V stop function selection is set to “0.0”.
The inverter will continuously run at the lower frequency limit if the frequency setting signal is lower than 1/100 (1%) of full scale.
134
Appendix Function Parameter List
P048
P049
P050
P051
The 1st Skip Frequency
The 2nd Skip Frequency
The 3rd Skip Frequency
Skip Frequency Band Width
If mechanical parts of the load resonate at a specific output frequency of inverter, continuous operation within frequency band width should be avoided by setting the skip frequency and the skip frequency band width.
· Up to 3 skip frequency values can be set, and the skip frequency band width can be set between 1 and 10 Hz.
■ Parameter P048: The 1st Skip Frequency
■ Parameter P049: The 2nd Skip Frequency
■ Parameter P050: The 3rd Skip Frequency
Data setting range (Hz) 0.0•0.2~400.0
* “0.0” indicates that there is no skip function setting.
■ Parameter P051: Skip Frequency Band Width
Data setting range (Hz) 0·1~10
* “0” indicates that there is no skip function setting.
135
Appendix Function Parameter List
P052
Cooling Fan ON-OFF Control Selection
· Operation modes of cooling fan in normal status and fault status can be set.
Setting value Operation of cooling fan
Details
Operation when heat sink is faulty
0
1
2
3
Fan ON when the power supply is switched ON.
Fan OFF when the power supply is switched OFF.
Fan ON at the start of the operation.
Fan OFF when the operation stops.
※ The status of the internal temperature of the inverter will be switched between
ON and OFF when in the stop status (It shall be switched to OFF when the internal temperature of the inverter is below 100℃).
Fan ON when the power supply is switched ON.
Fan OFF when the power supply is switched OFF.
Fan ON at the start of the operation.
Fan OFF when the operation stops.
※ The status of the internal temperature of the inverter will be switched between
ON and OFF when in the stop status (It shall be switched to OFF when the internal temperature of the inverter is below 100℃).
The inverter stops abnormally.
The inverter stops abnormally.
The inverter does not stop but sends out alarm.
The inverter does not stop but sends out alarm.
· The parameter is invalid to the models without cooling fans (3-phase 400
V/0.75 kW model).
·Please set the parameter “P056:—” to be “1” or “6” when the setting value “2” or “3” is used.
136
Appendix Function Parameter List
P053
Input Terminal Filter
Filter constants can be set to the control circuit terminals of the inverter to effectively remove the interference of the external signal input.
Setting value (times) 5~100
· If the setting value is too large, the interference resistance capability will be enhanced, but the response speed of the control input terminals will decrease.
· If the setting value is too small, the interference resistance capability will be weakened, but the response speed of the control input terminals will increase.
· When start/stop, forward run and reverse run signals are used to operate the inverter, internal processing time of the inverter will become longer even if the setting value is small. In this case, the response speed of the control input terminals will be slower than other terminals.
P054
Linear Speed Multiplier
When the setting value shown in “P005: Operation Status Monitor” is “1” (linear speed), multiplier relative to the output frequency can be set.
■ Parameter P054:Linear Speed Multiplier
Data setting range (times) 0.1~100.0
<Setting example> When linear speed is displayed
Linear speed (m/min) =F(Hz)×K (multiplier)
· To display the linear speed 25(m/min) at 50Hz, set the multiplier
(K) to “0.5”.
· Linear speed exceeding “9999” is displayed as “9.9.9.9”.
Related parameters: P005
137
Appendix Function Parameter List
P055
Setting Data Clear
All data can be restored to their factory settings via this parameter.
Setting value
0
1
Details
It indicates the value in normal status.
Except motor constants, all data will be restored to their factory settings.
2 All data will be restored to their factory settings.
■ Uninitialized motor constants when P055=2
Function Name
Motor Capacity
Motor Pole Number
Rated Voltage of Motor
Rated Frequency of Motor
Rated Current of Motor
Primary Resistance
Secondary Resistance
Energizing Inductance
Leakage Inductance
Energizing Current
Speed Control Percentage
Increment
Speed Control Integral Increment
Torque Limit Level
ParameterNo.
For the 1st motor
P203
For the 2nd motor
P216
P204
P205
P217
P218
P206
P207
P208
P209
P210
P211
P212
P219
P220
P221
P222
P223
P224
P225
P213 P226
P214
P215
P227
P228
· When the setting value is changed to a value other than “0” and button is pressed, the display will automatically switch to “0” afterwards to apply the change.
138
Appendix Function Parameter List
P056
Alarm LED Operation Selection
Alarm LED operation of the panel can be selected via this parameter.
Setting
Value
0
Function Name Details of Function
1
2
4
6
N/A
Full monitor alarm
Output voltage fault alarm
Abnormal temperature alarm
Abnormal cooling fan alarm
N/A (The LED lights up when fault trip occurs)
When any of the specified conditions (output voltage fault, overload, temperature abnormality, timer operation stop and cooling fan abnormality) is satisfied, the alarm LED will flicker.
When the setting value (P057) is reached, the alarm
LED will flicker.
When the setting value (P058) is reached, the alarm
LED will flicker.
When the heat sink temperature rises above 80 °C, the alarm LED will flicker.
When the timer operation is complete, the alarm LED will flicker.
(The signal is linked with the timer operation function.
When ∞ is displayed, the alarm LED will not flicker.)
When cooling fan abnormality occurs, the alarm LED will flicker.
· If fault trip occurs, the alarm LED will light up.
· Monitor function “n008: Alarm Type” can be used to identify the type of the current alarm.
· When alarm LED operation selection (parameter P056) is set to “1” and several alarms occur simultaneously, the alarm display order is as follows.
(If a higher-priority alarm is in operation, it will still be displayed even if a lower-priority alarm enters.)
· When the settings of “P124 to P126: Output TR1, TR2 and Ry Function Selection” are set to “11(r11)”, it can be output to the external devices as alarm signal.
Related parameters: P057, P058
P057
Upper Voltage Limit of Alarm LED
When alarm LED operation selection is set to “1” or “2”, the upper voltage limit applied to judge the output voltage fault alarm can be set via this parameter.
If the output voltage of inverter is higher than the setting value, the alarm LED will flicker as output voltage fault alarm.
Data setting range (V) 0.1~600.0
Related parameters: P056
139
Appendix Function Parameter List
P058
Upper Current Limit of Alarm LED
When alarm LED operation selection is set to “1” or “3”, the upper current limit applied to judge the overload fault alarm can be set via this parameter.
If the output current of inverter is higher than the setting value, the alarm LED will flicker as overload fault alarm.
Data setting range (A) 0.1~100.0
Related parameters: P056
P059
Password
To prevent accidental changes to the data after parameter setting is complete, password can be set via this parameter.
Data setting range 0000~9999
* “0000” indicates that there is no password.
To set a password, rotate the encoder to switch to the parameter setting mode to show “PS”. You may proceed to parameter setting after you enter the password and press the encoder.
140
Appendix Function Parameter List
Input and Setting of Password
Password Input
① Power ON the inverter.
The inverter shows “0000” when it is powered ON.
② Press
MODE to enter the Parameter Setting mode. MODE
③ Rotate the knob to “P0: Parameter Setting”.
④ Press the knob to display parameter P001.
⑤ Rotate the knob to “P059: Password”.
⑥ Press the knob to proceed to the setting of P055.
⑦
Rotate the knob to adjust the value of P055 to
“1234”.
⑧ Press the knob to apply the setting of “1234”.
Password Setting
⑨
Press
MODE to proceed to “P0: Parameter Setting” to show“P0--”.
⑩
Counterclockwisely rotate the knob to proceed to passwork lock mode to show“PS”.
MODE
ESC
141
Appendix Function Parameter List
P060
P061
MOP Function Selection
Acceleration/Deceleration Time for MOP Operation
Operation of frequency change can be set via these parameters when MOP function is used.
When acceleration/deceleration time is relatively short, frequency change is much easier with this function.
■ Parameter P060:MOP Function Selection
Setting
Value
0
1
Function Name
MOP operation linked with the acceleration/deceleration time
Operation linked with frequency setting
Details
Press the Left/Right rotation knob, the inverter will accelerate/decelerate according to the acceleration/deceleration time set with the parameter
P061.
Press the Left/Right rotation knob to switch to the frequency setting mode. But if operation linkage is not performed, press the knob after frequency is selected and acceleration/deceleration will be performed according to the acceleration/deceleration time set via parameter P001 and P002.
Disable the use of the MOP function. 2 MOP function disabled
■ Parameter P061: Acceleration/Deceleration Time for MOP Operation
Data setting range (s) 0.04·0.1~3600
Increment (s) 0.1(0.1~999.9), 1(1000~3600)
· When parameter P060 is set to “1”, applicable acceleration/deceleration time can be set via this parameter.
· When the data setting range is “0.04s”, the display is “0.0”.
· The maximum frequency is set via parameter P009 and P012.
142
Appendix Function Parameter List
· This function still applies even if parameter “P103 to P105: SW3 to SW5
Function Selection” is set to “20: Frequency ▲/▼ Setting”.
■ Operation when parameter P060 is set to “1: Operation Linked with
Frequency Setting”
· Rotate the Left/Right Arrow button of the rotation knob while the setting frequency is being displayed, the displayed data will flicker and proceed to a status under which the frequency setting data can be changed.
· Press the “knob” button to apply the frequency setting, the operation will start at the new frequency and implement the acceleration/deceleration operation.
· Press “ESC” button to return to its previous status while the frequency display data is flickering.
Related parameters: P001, P002, P009, P012, P060, P103 to P105
143
Appendix Function Parameter List
P062
P063
Torque Boost Increment
Torque Boost Response Increment
The boost increment and response increment can be set via these parameters in the auto torque boost mode.
■ Parameter P062: Torque Boost Increment
Data setting range (%) 0~200
· With the increase of the setting value, the voltage will rise accordingly, in this case, overcurrent will occur depending on the loads.
■ Parameter P063: Torque Boost Response Increment
Data setting range (%) 0~200
· With the increase of the setting value, response to the load change will be quickened, in this case, the motor is likely to produce vibration.
· Parameter P062 and P063 are valid only when parameter P011 and P140 are set to “Auto”.
144
Appendix Function Parameter List
P101
P102
P103
SW1 Function Selection
SW2 Function Selection
SW3 Function Selection
P104
P105
SW4 Function Selection
SW5 Function Selection
P106
SW6 Function Selection
Control function of SW1·2·3·4·5·6 (control circuit terminal No.1·2·3·4·5·6) can be set. Refer to the table below for the corresponding functions of the setting values of 1 to 18. If “b” contact input is applied, set the value with a letter “r”.
• “A” contact input =“0”: “ON” is detected when the SW signal is in a close state
(the terminal level is “L”).
• “B” contact input = “1”: “ON” is detected when the SW signal is in an oprn state (the terminal level is “H”).
SW used to set the function
SW1
Terminal No.1
SW2
Terminal No.2
SW3
Terminal No.3
SW4
Terminal No.4
SW5
Terminal No.5
SW6
Terminal No.6
0 No setting No setting No setting No setting No setting No setting
1 r1 Multi-step speed Multi-step speed Multi-step speed Multi-step speed Multi-step speed Multi-step speed
3 r3 Reset Lock
4 r4 JOG Selection
Reset Lock
JOG Selection
Reset Lock
JOG Selection
Reset Lock
JOG Selection
Reset Lock
JOG Selection
Reset Lock
JOG Selection
5 r5 External Fault Stop External Fault Stop External Fault Stop External Fault Stop External Fault Stop External Fault Stop
Parameter Setting
Disabled
Parameter Setting
Disabled
Parameter Setting
Disabled
Parameter Setting
Disabled
Parameter Setting
Disabled
Frequency Signal
Switch
Frequency Signal
Switch
Frequency Signal
Switch
Frequency Signal
Switch
Frequency Signal
Switch
Setting value
9 r9
The 2nd
Characteristics
Selection
The 2nd
Characteristics
Selection
The 2nd
Characteristics
Selection
The 2nd
Characteristics
Selection
The 2nd
Characteristics
Selection
The 2nd
Characteristics
Selection
10 r10 PID Control Switch PID Control Switch PID Control Switch PID Control Switch PID Control Switch PID Control Switch
11 r11
3-wire Stop
Command
3-wire Stop
Command
3-wire Stop
Command
3-wire Stop
Command
3-wire Stop
Command
3-wire Stop
Command
12 r12 Speed Search
14 r14
Speed Search Speed Search Speed Search Speed Search Speed Search
13 r13
Temporary Control
Stop of Winding
Mode
Temporary Control
Stop of Winding
Mode
Temporary Control
Stop of Winding
Mode
Temporary Control
Stop of Winding
Mode
Temporary Control
Stop of Winding
Mode
Temporary Control
Stop of Winding
Mode
Input Mode of
Winding Length
Input Mode of
Winding Length
Winding Length
Zero Clearing
Input Mode of
Winding Length
Winding Length
Zero Clearing
Input Mode of
Winding Length
Winding Length
Zero Clearing
Input Mode of
Winding Length
Winding Length
Zero Clearing
Input Mode of
Winding Length
Winding Length
Zero Clearing
17 r17 Forward/Reverse Forward/Reverse Forward/Reverse Forward/Reverse Forward/Reverse Forward/Reverse
18 r18 JOG Forward Run JOG Forward Run JOG Forward Run JOG Forward Run JOG Forward Run JOG Forward Run
19 r19 JOG Reverse Run JOG Reverse Run JOG Reverse Run JOG Reverse Run JOG Reverse Run JOG Reverse Run
20 r20
Frequency▲Settin g
Frequency▲Settin g
Frequency Storage
Setting
Winding Length
145
146
Appendix Function Parameter List
■ Multi-step speed SW Function
SW function is set so that it is used as multi-step speed function.
Multi-step speed function selection is set via parameter P301.
· When all SWs are set to multi-step speed function and 16-speed operation is performed, the four SWs with lower No. are valid as multi-step speed command SW.
(Set “SW1 to SW6” to multi-step speed function → Use SW1, SW2, SW3 and
SW4 as multi-step speed command.)
· Read “P301: Multi Speed Function Selection” carefully before using this function.
Related parameters: P301 to P334
■ Reset Function
Fault stop status can be reset through external control if an inverter fault trip
(stop) occurs.
When a fault trip occurs and SW signal input is turned ON, the fault trip status will be cleared if the SW signal input is turned OFF.
Appendix Function Parameter List
■ Reset Lock Function
When a fault trip occurs, clearing of fault trip status with stop signal is disabled to perform reset operation with SW signal after identifying the details of fault trip and eliminating the abnormality.
· Normally, SW signal is input with ON status.
· When a fault trip occurs, the inverter will maintain the trip status even if stop signal and reset signal are input.
· After the abnormality is identified and eliminated, the fault trip will be reset when this SW is turned OFF.
* Turn reset lock signal OFF and press
STOP
button to reset the fault.
In addition, turn the fault reset signal OFF.
147
Appendix Function Parameter List
■ JOG Function
Micro operations such as position adjustment can be performed with external control signals.
Signal input terminals for controlling micro operation from external devices can be set via parameter P101 to P106.
But Run Command Selection (parameter P003) should be set through external control.
· Turn the signal input ON, and it will enter JOG operation mode.
· JOG operation is performed according to “P019: JOG Frequency”, “P020:
JOG Acceleration Time” and “P021: JOG Deceleration Time” settings, after run/stop and forward/reverse run signals are input via terminals.
<Example> When SW1 (parameter P101) is set to “16 (Run/Stop)”; SW2
(parameter P102) is set to “17 (Forward/Reverse Run)”; SW3
(parameter P103) is set to “4 (JOG Selection)”; operations are performed as follows.
7
1
2
3
Note 1: During JOG operation, please turn the JOG selection signal ON (time
B) and then turn the run signal ON.
Note 2: During reverse run operation, please turn the reverse run signal ON
(time A) and then turn the run signal ON.
Related parameters: P019 to P021
148
Appendix Function Parameter List
■ External Fault Stop Function
Signal input terminal for applying fault stop (emergency stop) to the inverter through external devices can be set.
· The inverter will stop output immediately after the external fault stop input
(setting value = 5) turns SW signal ON and “AU” is displayed.
· Input signal logic setting can be changed by setting the SW function parameter to “r5”.
<Example> When SW1 (parameter P101) is set to “16 (Run/Stop)”; SW3
(parameter P103) is set to “r5” (fault stop input contrary to the logic) , operations are performed as follows.
7
1
3
* When external fault stop signal is set to contact B input, fault reset can be applied after run signal is turn OFF, even if external stop signal is “ON”. But fault trip will occur after the run signal is turned “ON” again. So please turn the run signal “ON” after the external fault stop signal being turned “OFF” for normal operation.
■ Parameter Setting Disabled Function
The signal input terminal for disabling the parameter setting through external control can be set.
· After signal input is turned ON, setting parameters with the operation panel and communication are disabled.
· When the signal input is turned ON, function parameters and built-in memory parameters cannot be set but be monitored.
· During data setting, data cannot be changed through the SW function even if button is pressed when the signal is ON.
149
Appendix Function Parameter List
■ Coast-to-stop Function
The signal input terminal for applying coast-to-stop through external control can be set.
· During operation, the inverter will stop output immediately after signal input is turned ON and “0.0” is displayed.
(Without fault indication and fault alarm output)
· The inverter will run immediately after signal input is turned OFF and run signal is turned ON.
[Note] The inverter will start as the signal input is turned OFF, so please ensure personal safety before operation.
· The inverter will stop normally after the run signal is turned OFF together with signal input being turned OFF.
<Example> When SW1 (parameter P101) is set to “16 (Run/Stop)”; SW3
(parameter P103) is set to “7 (coast-to-stop)”, and run command selection
(parameter P003=2) is used;
150
Appendix Function Parameter List
■ Frequency Signal Switching Function
Signal input terminal for switching frequency setting command from “The 1st
Frequency Setting Signal (command set via parameter P004)” to “The 2nd
Frequency Setting Signal (command set via parameter P118)” can be set.
This function is valid when parameter “P119: The 2nd Analog Input Function
Selection” is set to “0: The 2nd Frequency Setting Signal”.
· When signal input is OFF: The 1st Frequency Setting Signal.
· When signal input is ON: The 2nd Frequency Setting Signal.
Related parameters: P118, P119
151
Appendix Function Parameter List
■ The 2nd Characteristics Selection Function
When SW signal is ON, the inverter will run according to the 2nd
Characteristics Function settings as follows.
Switching button OFF
P001: The 1st Acceleration Time
P002: The 1st Deceleration Time
P013: Base Frequency
P011: Torque Boost
P023: Electronic Thermal Selection
P024: Thermal Current Setting
P014 Change Point Frequency1
P015: Change Point Voltage 1
P016: Change Point Frequency 2
P017: Change Point Voltage 2
P203: Motor Capacity
P204: Motor Pole Number
P205: Rated Voltage of Motor
P206: Rated Frequency of Motor
P207: Rated Current of Motor
P208: Primary Resistance
P209: Secondary Resistance
P210: Energizing Inductance
P211: Leakage Inductance
Switching button ON
P317: The 2nd Acceleration Time
P318: The 2nd Deceleration Time
P139: The 2nd Base Frequency
P140: The 2nd Torque Boost
P141: The 2nd Electronic Thermal Selection
P142: The 2nd Thermal Current Setting
P143: The 2nd Change Point Frequency 1
P144: The 2nd Change Point Voltage 1
P145: The 2nd Change Point Frequency 2
P146: The 2nd Change Point Voltage 2
P216: The 2nd Motor Capacity
P217: Pole Number of the 2nd Motor
P218: Rated Voltage of the 2nd Motor
P219: Rated Frequency of the 2nd Motor
P220: Rated Current of the 2nd Motor
P221: Primary Resistance of the 2nd Motor
P222: Secondary Resistance of the 2nd Motor
P223: Energizing Inductance of the 2nd Motor
P224: Leakage Inductance of the 2nd Motor
P212: Energizing Current
P213: Speed Control Percentage
Increment
P214: Speed Control Integral Increment
P225: Energizing Current of the 2nd Motor
P226: Speed Control Percentage Increment of the 2nd Motor
P227: Speed Control Integral Increment of the
2nd Motor
P228: Torque Limit Level 2 of the 2nd Motor P215: Torque Limit Level 1
Note: Ensure personal safety before switching characteristics.
152
Appendix Function Parameter List
■ Control Switching Function
Signal input terminal for cancelling PID control through external control can be set. When the signal input is turned ON, the inverter switches from “PID control” to the command set via parameter P004.
The function is valid when parameter “P118: The 2nd Analog Input Function
Selection” is set to “1 to 3”.
·When the signal input is OFF: PID control or control based on auxiliary frequency signal.
·When the signal input is ON: command set via parameter P004.
■ 3-wire Stop Command Function
Signal input terminal for executing 3-wire stop command can be set.
When “3-wire stop signal” is ON, “run signal” or “forward/reverse run signal” can be held automatically. Also, switching to OFF will cancel the holding status.
· Please set “Run Command Selection” via parameter P003.
· Set the SW1 to SW6 terminals to be 3-wire stop command function (contact
B input) (always be contact B input regardless of the setting value is 11 or r11).
Related parameters: P003
153
Appendix Function Parameter List
■ Frequency ▲/▼ Setting Function
When frequency and parameter “P103 to P105” are set to “digital setting with operation panel (P004 = 1)” and “20” respectively, SW3 and SW4 can be used to change frequency while SW5 is used to save this frequency.
· SW3: During ON, frequency increases. (During OFF, the existing frequency is held.)
· SW4: During ON, frequency decreases. (During OFF, existing frequency is held.)
· SW5: Turn ON once and OFF again to save the frequency at that time.
(The frequency can be saved even if the power is turned OFF.)
Note 1: The operating frequency will not be changed when both▲button (SW3) and ▼button (SW4) are turned OFF or ON (i.e. in A or B area etc).
Note 2: The operating frequency will not be saved when “frequency memory operation of SW5” and “frequency setting in frequency setting mode” on the operation panel are not performed.
· When parameter “P060: MOP Function Selection” is set to “0”, the acceleration/deceleration time set via parameter “P061:
Acceleration/Deceleration Time for MOP Operation” will be used.
Please set P106 to be “0” or “1”when using this function.
Related parameters: P004, P060, P061
154
Appendix Function Parameter List
■ Speed Search Function
· The inverter will apply minor DC voltage to the motor, detect its rotation speed and restart it at this frequency when the motor rotates freely due to inertia, which is the so-called “speed search function”.
· There are 3 methods to start the speed search.
1) Through input signal from control terminals (SW1 to SW6)
Related parameters: P101 to P106 (SW1 to SW6 Function Selection)
2) At motor startup
Related parameters: P357 (Speed Search at Startup)
3) During retry operation of inverter after fault trip occurrence
Related parameters: P029 (Retry Function), P361 (Speed Search Selection during Retry)
· Perform speed search according to the following procedures.
· Conditions of speed search can be set via parameter P359 to P364.
· The start of speed search through control input is only valid during free operation. Therefore, even if the control input assigned to speed search is
ON, the speed search will nevertheless be ignored.
· If the rotation speed is too low and the rotation direction does not match the rotation command, the rotation speed may not be sensed.
· The sensing function may fail if the speed search is performed for the motor with capacity smaller than the inverter.
· “CAL” will be displayed on the operation panel during speed search. During the displaying, there is minor DC voltage applied on the motor externally.
155
Appendix Function Parameter List
■ Winding Mode Control Function
· Winding mode control function will operate at the triangular-wave-shaped frequency as shown in the following graph.
· When parameter “P335: Winding Mode Control Selection” is set to “1” or “2”, winding mode control function will start after run command is turned ON. During startup, the inverter will keep on accelerating within the time set via parameter
“P001: The 1st Acceleration Time” until the set frequency is reached.
· The conditions of winding mode control are set via parameter P335 to P339.
· The operational mode of winding mode is set via parameter "P340:Winding Mode
Operation Selection". When parameter "P340" is set to "1" or "3", 2-point mode starts, in this case, set frequency of second point via parameter "P302: Second
Frequency", set stop length via parameter "P344: Winding Stop Length", the basic frequency will change to the second frequency with the increase of the winding length, the change of linear and when the winding length reaches the stop length.
When P340 is set to "2" or "3", random mode starts, in this case, set random change range via parameter "P341: Max Random Rise Time Coefficient" and "P342:
Minimum Random Rise Time Coefficient", yet when P342<P341, random function doesn't start. Especially, when P340 is set to "3", it will be 2-point random mode, the basic frequency will change from fixed frequency to second frequency with the change of winding length. And, rise time coefficient change randomly in the random range.
· When parameter “P101 to P106: SW1 to SW6 Function Selection” is set to “13”, and SW input of corresponding control input terminals (SW1 to SW6) are ON, the inverter will terminate winding mode control and continue to run at the frequency when SW input (SW1 to SW6) is turned ON.
· When stop command is turned ON, the deceleration will be performed to stop the inverter according to the value set via parameter “P002: The 1st Deceleration Time” regardless of the operating frequency.
156
Appendix Function Parameter List
If the following functions start together with winding mode control function, such function will take precedence. And what’s more, winding mode control will not start when the following functions operate.
· Trial operation function
· Auto-tuning function
· Timer operation function
· PID function
■ Winding Mode Input Length
When parameter “P335: Winding Mode Control Selection” is set to “1” or “2”, parameter “P106: SW6 Function Selection” is set to “20” or “14”, and pulse is input from SW6, length can be calculated based on “P343: Winding Length
Multiplier”.
· The calculated result will be displayed in n022.
Winding length=
(Pulse “n” input to SW6)×(P343: Winding Length Multiplier )
1000
When any multi-function SW is set to “14 (winding length input mode)” , the response speed will be slower.
When the input pulse band width is shorter than 15ms, set P106 to “20” and input from SW6.
157
Appendix Function Parameter List
■ JOG Forward Run/JOG Reverse Run
Micro operations such as position adjustment can be performed with external control signals.
Signal input terminals for controlling micro operation from external devices can be set via parameter P101 to P106.
JOG commands of all operations are valid, but the JOG command should take precedence.
· Turn the signal input ON, and it will enter JOG operation mode.
· JOG operation is performed according to “P019: JOG Frequency”, “P020:
JOG Acceleration Time” and “P021: JOG Deceleration Time” settings, after run/stop and forward/reverse run signals are input from terminals.
<Example> When SW1 (parameter P101) and SW2 (parameter P102) are respectively set to “18 (JOG Forward Run)” and “19 (JOG Reverse Run)”, operation are performed as follows.
Related parameters: P003, P019, P022
158
Appendix Function Parameter List
P107
Pulse Input Frequency
The number of pulses per second (pulse frequency) at the maximum output frequency can be set using this parameter.
Setting Range (kHz) 1.0~40.0
P108
Pulse Input Filter
The responsiveness to pulse input signal can be set using this parameter.
Please set at the time when diffirent frequency is sensed.
Setting Range (times) 10~100
P109
PWM Signal Average Times
The inverter measures and calculates ON time and OFF time of each PWM cycle used as frequency command.
When using this parameter, the times of each PWM cycle command should be averaged, and then the average operation times are set as final output frequency.
Data Setting Range (times) 1~100
* With the increase of the average times, the frequency command will become stable, while the response speed will decrease.
159
Appendix Function Parameter List
P110
PWM Signal Cycle
PWM signal cycle can be input via this parameter.
Data setting range(msec) 1.0~2000
· The output frequency controlled by PWM signal is “0 V stop or the minimum frequency (without ON status)” and “the maximum frequency (without OFF status)”.
· Due to the fact that the output frequency accuracy relative to input signal will decrease around the minimum frequency and maximum frequency, do not use the inverter for precise frequency control.
· The 2nd frequency setting signal takes precedence over the PWM frequency signal if the 2nd frequency setting signal is selected (ON).
· PID control function is invalid when PWM frequency signal is selected.
PWM frequency signal cannot be used as PID setting value (SP).
■ Connection and Function Descriptions of Control Circuit Terminals
■ Relationship between PWM Signal and Frequency Command Value
■ Relationship between Pulse Signal and Frequency
Please set the number of pulse input per second (pulse frequency) at the maximum output frequency using parameter “P107: Pulse Input Signal Frequency”.
· When parameter P009 is set to “50” and “60”, the maximum output frequency shall be “50Hz” and “60Hz” accordingly; when it is set to “FF” or “3C”, the maximum output frequency shall be the value of parameter P012.
Related parameters: P009, P012
160
Appendix Function Parameter List
P111
Analog Input Filter
Filter constant of analog input terminal (control circuit terminal⑫and⑭) can be set to eliminate external interference caused by external voltage or current frequency setting signals.
Data Setting Range (times) 5~200
· Filter constant of analog input signals for control circuit terminal⑬and⑭ share the same setting value.
· Frequency command will become stable with the increase of the setting value (average times), while the response speed will decrease.
Related parameters: P004, P119
161
Appendix Function Parameter List
P112
P113
Bias Frequency Setting
Gain Frequency Setting
The relationship between output frequency and frequency setting signal can be adjusted freely. Please use this function according to the applications.
■ Parameter P112: Bias Frequency Setting
Data setting range (%) -99.0~250.0
■ Parameter P113: Gain Frequency Setting
Data setting range (%) 0.0~500.0
· Bias frequency and gain frequency are set in terms of pencentage (%) of the maximum output frequency (100%) (parameter P012).
· A frequency exceeding the maximum frequency or the upper frequency limit will not be output.
Also, the frequency will not drop below the lower frequency limit.
· The inverter will not perform reverse run operation even if negative frequency setting signal is input.
■ When bias frequency is set to be “positive” ■ When bias frequency is set to be “negative”
Related parameters: P004, P009, P012
162
Appendix Function Parameter List
P114
Analog Direction Mode
Used to set the direction after the frequency command had been set to analog signal.
■ Parameter P114: Analog Direction Mode
Setting Details
0 Analog direction mode is disabled.
1
2
If frequency is controlled by the analog quantity, the forward run will switch to reverse run at the threshold value of 50% of the maximum analog quantity input.
If frequency is controlled by the analog quantity, the reverse run will switch to forward run at the threshold value of 50% of the maximum analog quantity input.
· Control the direction based on the analog quantity.
P114 is set to “0”
Output
Frequency
%
100%
P114 is set to “1”
Output
Frequency
%
100%
100%
The 1st analog input (%)
Forward run
Reverse run
100%
The 1st analog input (%)
P114 is set to “2”
Output
Frequency
%
100%
Reverse run
Forward run
The 1st analog input (%)
100%
· The direction setting mode (dr) is invalid when the setting value is “1” or “2”.
163
Appendix Function Parameter List
P115
P116
The 2nd Bias Frequency Setting
The 2nd Gain Frequency Setting
Output frequency and the 2nd analog input signal can be adjusted freely.
■ Parameter P115: The 2nd Bias Frequency Setting
Data setting range (%) -99.0~250.0
■ Parameter P116: The 2nd Gain Frequency Setting
Data setting range (%) 0.0~500.0
· The 2nd bias frequency and the 2nd gain frequency are set in terms of pencentage (%) of the maximum output frequency (100%) (parameter P012).
· A frequency exceeding the maximum frequency or the upper frequency limit will not be output.
Also, the frequency will not drop below the lower frequency limit.
· The inverter will not perform reverse run operation even if negative frequency setting signal is input.
■ Relationship between the 2nd Frequency Setting Signal and the Output Frequency
164
Appendix Function Parameter List
P117
The 2nd Analof Direction Mode
Used to set the direction after the frequency command had been set to analog signal.
■ Parameter P117: The 2nd Analog Direction Mode
Setting Details
0 Analog direction mode is disabled.
1
2
If frequency is controlled by the 2nd analog quantity, the forward run will switch to reverse run at the threshold value of 50% of the maximum analog quantity input.
If frequency is controlled by the 2nd analog quantity, the reverse run will switch to forward run at the threshold value of 50% of the maximum analog quantity input.
· Control the direction based on the analog quantity.
P117 is set to “0”
Output frequency
(%)
100%
P117 is set to “1”
Output frequency
(%)
100%
100%
The 2nd frequency input (%)
Forward run
Reverse run
100%
The 2nd frequency input (%)
P117 is set to “2”
Output frequency
(%)
100%
Reverse run
Forward run
The 2nd frequency input (%)
100%
· The direction setting mode (dr) is invalid when the setting value is “1” or “2”.
165
Appendix Function Parameter List
P118
The 2nd Analog Input Function Selection
The control function of the 2nd analog input terminal (control circuit terminal
No.16) can be selected.
Setting value
0
1
2
Details
The 2nd frequency setting signal
Measured value of PID control
Bias signal of PID control
3 Auxiliary frequency setting signal
■The 2nd frequency setting signal (setting value = “0”)
· The 2nd analog input terminal can be used as the 2nd frequency setting signal.
· Frequency setting command can be switched between the 1st frequency setting signal and the 2nd frequency setting signal depending on the input status set via parameter “P101 to P106: SW1 to SW6 Function Selection”.
SW with OFF input: the 1st frequency setting signal.
SW with ON input: the 2nd frequency setting signal.
■Measured Value of PID Control (setting value = “1”)
· The 2nd analog input terminal can be used as feedback signal of PID control
(measured value PV).
· Input signals (0 ~ 5 V, 0 ~ 10 V, 4 ~ 20 mA and 0 ~ 20 mA) are fed back as measured values (PVs) of PID control (positive values: 0
~
100%).
· After parameter P118 is set to “1”, set target value (SP) to the output frequency through parameter “P004: Frequency Setting Signal” to perform PID control so that measured value PV will approach the target value SP and the output frequency will be changed accordingly.
· Parameters for PID control can be set via parameter P345 to P354.
166
Appendix Function Parameter List
■ Bias Signal of PID Control (setting value = “2”)
· The 2nd analog input terminal can be used as measured value of PID control
(bias signal).
· Input signals (0 ~ 5 V, 0 ~ 10 V, 4 ~ 20 mA and 0 ~ 20 mA) are fed back as bias signal of PID control (setting example: -10%
~
+10%).
· Bias value can be converted inside the inverter via parameter “P115: The
2nd Bias Frequency Setting” and “P116: The 2nd Gain Frequency Setting”.
<Example> When the analog input ranges from 0 to 5 V and both the 2nd bias value and the 2nd gain are set to “10”
(%)
10
第2增益
P116=10.0
The 2nd bias
P115=10.0
P115=-10.0
0
2.5
Analog input voltage
-10
· After parameter P118 is set to “2”, conduct the target value (SP) PID control based on the bias signal input to the analog input terminal, the output frequency will change accordingly. In this case, the bias signal (PV–SP) under
PID control is the bias signal of the 2nd analog input terminal.
· Parameters for PID control can be set via parameter P345 to P354.
167
Appendix Function Parameter List
■Auxiliary Frequency Setting Signal (setting value = “3”)
· The 2nd analog input terminal can be used as auxiliary frequency setting signal.
· Input signals (0
~
5 V, 0
~
10 V, 4
~
20 mA and 0
~
20 mA) are fed back as auxiliary frequency setting signal added to the 1st frequency setting signal (%)
(setting example: -10%
~
+10%).
· The setting value of auxiliary frequency setting signal can be converted inside the inverter via parameter “P115: The 2nd Bias Frequency Setting” and
“P116: The 2nd Gain Frequency Setting”.
<Example> When the analog input ranges from 0 to 5 V and both the 2nd bias value and the 2nd gain are set to “10”
(%)
10 The 2nd gain
P116=10.0
The 2nd bias
P115=10.0
P115=-10.0
0
2.5
Analog input
voltage
-10
· It can be used when the result of PID calculation conducted by external devices such as PLC is added to the speed command value.
· The inverter’s output frequency is determined by the following formula.
Output frequency=Max. output frequency×(The 1st frequency setting signal
(%) + auxiliary frequency setting signal (%))
Related parameters: P004, P101 to P106, P115 to P116, P345 to P354
168
Appendix Function Parameter List
P119
The 2nd Analog Input Singal Selection
Setting signal of the 2nd analog input terminal (control circuit terminal⑬) can be selected.
Setting value
2
3
4
5
Details of setting signal
0~5V
(voltage signal)
0~10V
(voltage signal)
4~20mA
(current signal)
0~20mA
(current signal)
Operation method and control circuit terminal connection diagram
Terminal ⑬ and ⑭ (13: +, 14: -)
Terminal ⑬ and ⑭ (13: +, 14: -)
Terminal ⑬ and ⑭ (13: +, 14: -)
Terminal ⑬ and ⑭ (13: +, 14: -)
· The inverter will run or stop as defined by the setting value of “P047: 0V Stop
Function Selection”.
To make the 0V stop function invalid, please set parameter P047 to “0.0”.
Related parameters: P047, P115, P116
169
Appendix Function Parameter List
P120
Analog Output Function Selection
Functions of “0 to 10V voltage signal” from the control circuit terminal No. 15 can be set here.
Setting value
0
Details
Signals in proportion to output frequency are output.
1 Signals in proportion to output current are output.
■ Relationship between 0 to 10V voltage signal and output frequency/output current
<In proportion to the output frequency> < In proportion to the output current>
(V)
10
Max. output frequency
(V)
10
150% of the rated output current
0 0
Output frequency Output Current
P121
Compensation for PWM Output Duty Ratio
Compensation for output duty ratio of the “output status signal (PWM)” can be made here.
Data setting range (%) 25~100
■ Adjustable Range (full scale value)
· PWM signal: PWM signal duty ratio×Percentage set with P121
(%)
100
(%)
100
Max. output frequency
150% of the rated output current
25 25
Output frequency Output Current
Relationship between PWM duty ratio and output frequency when P121=100.
Relationship between PWM duty ratio and output frequency when P121=25
170
Appendix Function Parameter List
P122
PWM/Pulse Output Function Selection
be set here.
Setting value
0
Details
Signals in proportion to output frequency are output.
1 Signals in proportion to output current are output.
■ Relationship between PWM signal output and output frequency/output current
(%)
100
Max. output frequency
(%)
100
150% of the rated output current
Output frequency Output Current
■ Relationship between pulse signal output and output frequency/output current
(%)
100
Max. output frequency
(%)
100
150% of the rated output current
Output frequency Output Current
· The “pulse percentage” shown in the diagram refers to the percentage of the output pulse frequency in the setting value of “P147: Pulse Output
Frequency”.
P123
PWM Output Cycle
Set the output cycle for PWM when the Tr1 output function is set to be PWM output.
■ Parameter P123: PWM Output Cycle
Data setting range[msec] 1~2000
· Cycle of PWM wave output can be set.
171
Appendix Function Parameter List
P124
P125
Output TR1 Function Selection
Output TR2 Function Selection
open-collector output 2 (control circuit terminal ⑨ to ) can be set.
P124
(TR1)
0
P125
(TR2)
0
Function
Run signal
ON condtions for open-collector output
With run signal ON or during inverter output
1 1 Reverse run signal When inverter is in reverse run status
When output frequency is within ±2 Hz of setting frequency
When the output current is above 140% of the rated current or the electronic thermal level is reached.
Setting value
5
6
7
8
11
13
14
5
6
7
8
11
-
-
Current sensing (1)
Current sensing (2)
Fault alarm (1)
Fault alarm (2)
Alarm
Output status signal
(PWM)
Output status signal
(pulse)
When the output current is above the sensing current level (parameter P129 setting)
When the output current is below the sensing current level (parameter P129 setting)
When fault trip occurs in the inverter
When the inverter is in normal status (OFF for fault trip status)
When one cycle of timer operation completes
(output is available only during waiting time).
When timer operation completes (with “t.End” displayed).
Output is available with alarm LED flickering.
When speed search starts, the open-collector output is ON; when the speed search completes, the open-collector output is OFF.
PWM signals in proportion to output frequency or output current will be output.
Pulse signals in proportion to output frequency or output current will be output.
· The setting value “5” and “6” are used to set the delay time of current detection signal with “P130: Current Sensing Delay Time”.
· The setting value “10” is used to output the time set with “P326: Continuous
Waiting Time of Timer Operation”.
· Output frequency ratio or output current ratio of the setting value “13” and
“14” can be set via parameter P121. Setting value “13” and “14” can only be used to set open-collector output 1 (TR1).
Related parameters: P326, P127, P129 to P131
172
Appendix Function Parameter List
P126
Output RY Function Selection
Functions of relay output (control circuit terminal A, B and C) can be set.
· Energizing in ON status: The relay is turned ON when the coil is energized.
(Signal ON status = ON between terminals A and C, OFF between terminals B and C)
· Non-energizing in ON status: The relay is turned ON when the coil is not energized.
(Signal ON status = ON between terminals A and C, OFF between terminals B and C)
Setting value
Energizing in
ON status
0
Non-energizing in
ON status r0
1 r1
Function
Run signal
Reverse run signal
ON conditions for relay
With run signal ON or during inverter output
When inverter is in reverse run status
When the output current is above 140% of the alarm reached.
7
8
11 r7 r8 r11
Current
When the output current is above the sensing current level (parameter P129 setting)
Current
When the output current is below the sensing current level (parameter P129 setting)
Fault alarm (1) When fault trip occurs in the inverter
Fault alarm (2)
When the inverter is in normal status (OFF for fault trip status)
When one cycle of timer operation completes
(output is available only during waiting time).
When timer operation completes (with “t.End” displayed).
Alarm Output is available with alarm LED flickering. output is ON; when the speed search completes, the open-collector output is OFF.
· The setting value “5” and “6” are used to set the delay time of current detection signal with “P130: Current Sensing Delay Time”.
· The setting value “10” is used to output the time set with “P326: Continuous
Waiting Time of Timer Operation”.
Related parameters: P326, P128 to P130
173
Appendix Function Parameter List
P127
P128
Sensing Frequency[Output TR]
Sensing Frequency[Output RY]
Open-collector 1, 2 and relay output can be used to set the frequency sensed when outputting frequency sensing signals.
■ Parameter P127: Sensing Frequency [Output TR]
Data setting range (Hz) 0.0·0.2~400.0
· It is valid in open-collector output 1 and 2.
· “0.0” indicates 0V stop (0.0).
■ Parameter P128: Sensing Frequency [Output RY]
Data setting range (Hz) 0.0·0.2~400.0
· “0.0” indicates 0V stop (0.0).
■ Relationship between output frequency and each output signal
Related parameters: P124 to P126
174
Appendix Function Parameter List
P129
P130
Current Sensing Level
Current Sensing Delay Time
Open-collector 1, 2 and relay output can be used to set current sensing level and delay time when current sensing signal is output.
■ Parameter P129: Current Sensing Level
Data setting range (A) 0.1~100.0
■ Parameter P130: Current Sensing Delay Time
Data setting range (s) 0.1~10.0
· Current sensing delay time refers to the delay time for a signal to switch from
OFF to ON.
The delay time for a signal to switch from ON to OFF is about 100 ms (fixed value).
Related parameters: P124 to P126
175
Appendix Function Parameter List
P131
P132
RS485 Communication Protocol Selection
RS485 Communication Station No. Setting
P135
P136
RS485 Parity Check
RS485 Timeout Sensing
P133
RS485 Communication Speed Setting
P137
RS485 Wait-to-send Time
P134 RS485Stop Bit Length P138 RS485 Judging Time for TEXT Completion
Important parameters necessary for sending commands to inverter through communication can be set.
■ P131: RS485 Communication Protocol Selection
MK300 is based on three protocols: MEWTOCOL-COM, Modbus(RTU) and
Modbus (ASCII). Either protocol can be selected.
Setting value Details of function
0 MEWTOCOL-COM
1 Modbus(RTU)
2 Modbus(ASCII)
■ P132: RS485 Communication Station No. Setting
Data setting range 1~31
■ P133: RS485 Communication Speed Setting
Setting value Details of function
48 4800bps
96 9600bps
192 19200bps
384 38400bps
576 57600bps
1152 115200bps
■ P134: RS485 Stop Bit Length
Setting value Details of function
1 1bit
2 2bit
■ P135: RS485 Parity Check
Setting value
0
Details of function
Without parity check
176
Appendix Function Parameter List
■ P136: RS485 Timeout Sensing
If the status without communication continues for more than the allowable time when the Operation Command Selection (P003) and Frequency Setting Signal
(P004) are in the communication setting mode, the inverter will abnormally stop (displaying “OP”). Such allowable time can be set here.
Data setting range(sec) 0.0·0.1~60.0
* “0.0” indicates a setting without timeout sensing.
■ P137: RS485 Wait-to-send Time
Data setting range(msec) 1~1000
■ P138: RS485 Judging Time for TEXT Completion
Data setting range(msec) 3~200
* The setting is only valid when protocol Modbus (RTU) is used.
· Please cut off the primary power supply after the values of conmmunication-related parameter P131 to P138 had all been set.
After the power supply reset, the setting values will be applied in the inverter.
177
Appendix Function Parameter List
P139
The 2nd Base Frequency
The 2nd base frequency can be selected and set with the 2nd characteristics selection button.
(It is only valid when parameter P009 is set to “FF” or “3C”.)
■ Parameter P139:The 2nd Base Frequency
Data setting range (Hz) 45.0~400.0
· The maximum output frequency is the setting value of parameter P009 (V/F
Mode) or parameter P012 (Max. Output
Frequency)
· If “P009: V/F Mode” is set to “50” or “60”, the maximum output frequency and base frequency will be fixed values.
· A frequency value exceeding “P046: Upper Frequency Limit” cannot be output.
· If a general-purpose motor with rated frequency of 50/60 Hz is running at a frequency value exceeding the ratings, the motor may be damaged. Therefore, please set the frequency to match motor characteristics.
· If the base frequency is required to be changed together with the maximum output frequency for a dedicated high-speed motor etc., such change can also be changed via this parameter.
· When running the general-purpose motor at a frequency value exceeding the universal frequency, please set the base frequency to the rated output frequency (50/60 Hz) of general-purpose motor.
· When the general-purpose motor reaches a level exceeding the base frequency (normally 50/60 Hz), the motor will have the constant output characteristics and the generated torque will drop in reverse proportion to the frequency.
Related parameters: P009, P012, P101~P106, P046, P140, P143~P146
178
Appendix Function Parameter List
P140
The 2nd Torque Boost
The 2nd torque boost can be selected and set with the 2nd characteristics selection button. The larger the setting value is, the higher output voltage and torque boost are.
·After the mode is set to “auto torque boost”, the output voltage will be changed automatically according to the load fluctuation. To set “Auto torque boost”, please rotate the knob once more when the operation panel displays “40”.
Name
Auto torque boost
Manual torque boost
Data setting range (%)
Auto
0~40%
· If the boost level setting is too high, overcurrent fault, overload fault, motor overheating or excessive noise may occur.
· The motor current will rise after the boost level is increased. Please carefully consider the settings of “P141: The 2nd Electronic Thermal Selection” and
“P142: The 2nd Thermal Current Setting”.
· Auto-tuning is necessary when auto torque boost is selected. Please use it after the motor constants had been correctly set.
( For the auto-tuning methods, please carefully read “4.14 Auto-tuning” .)
179
Appendix Function Parameter List
P141
P142
The 2nd Electronic Thermal Selection
The 2nd Thermal Current Setting
Electronic thermal operation level can be selected and set with the 2nd characteristics selection button when the inverter output is stopped. Operation coasts to stop when OL is displayed.
■ Example for setting current and thermal operation (P141=1)
·Setting current ×100% Does not operate
·Setting current ×125% Operate (OL trip)
■ Parameter P141: The 2nd Electronic Thermal Selection
Setting value
Validity of function
Details of function
1 Enabled Without output frequency derating
2 Enabled With output frequency derating
3 Enabled Forced air-cooled motor specification
* About frequency derating
Cooling performance of the motor will be reduced at lower speed. To handle the problem, this function can automatically compensate operation level.
■ Parameter P141=1 ■ Parameter P141=2 ■ Parameter P141=3
■ Parameter P142: The 2nd Thermal Current Setting
Data setting range (A) 0.1~100.0
* Please make settings according to the rated current of the applicable motor.
Related parameters: P101 to P106
180
Appendix Function Parameter List
P143
P144
The 2nd Change Point Frequency 1
P145
The 2nd Change Point Voltage 1 P146
The 2nd Change Point Frequency 2
The 2nd Change Point Voltage 2
Change point 1 and 2 can be selected in 3-point mode of “P009: V/F Mode”.
(It is only valid when parameter P009 is set to “3C”.)
■ Parameter P143: The 2nd Change Point Frequency 1
Data setting range (Hz) 0.2~400.0
■ Parameter P144: The 2nd Change Point Voltage 1
Data setting range (%) 0.0~100.0
■ Parameter P145: The 2nd Change Point Frequency 2
Data setting range (Hz) 0.2~400.0
■ Parameter P146: The 2nd hange Point Voltage 2
Data setting range (%) 0.0~100.0
· Read “P009: V/F Mode” carefully before setting.
· The 2nd change point frequency 1 and 2 will operate according to the setting value of the base frequency when set to a value higher than the base frequency.
· The 2nd change point frequency 2 will operate according to the setting value of the 2nd change point frequency 1 when set to a value lower than the 2nd change point frequency 1.
· When setting “P140: The 2nd Torque Boost”, the 2nd change point voltage 1 and
2 will operate according to the setting value of the 2nd torque boost if set to a value lower than the 2nd torque boost level.
· The 2nd change point voltage 2 will operate according to the setting value of the
2nd change point voltage 1 when it is set to below the 2nd change point voltage 1.
· Please note that sharp acceleration/deceleration or overcurrent may occur depending on setting values and load status if data is changed during operation.
· The auto torque boost mode will take precedence if the auto torque boost mode is selected via parameter “P140: The 2nd Torque Boost”, in this case, settings related to 3-point mode (parameter P143 to P146: Change Point Voltage and Change Point
Frequency) will become invalid.
Related parameters: P009, P012, P101 to P106, P139, P140
181
Appendix Function Parameter List
P147
Pulse Output Frequency
The number of pulses per second (pulse frequency) at the maximum output frequency or 150% of the rated output current can be set using this parameter.
Setting Range (kHz) 1.0~10.0
P148
Pulse Output Duty Ratio
The pulse output duty ratio can be adjusted within the range of 25% to 75%.
Setting Range (%) 25~75
P149
Analog Output Voltage Compensation
Output compensation for “0 to 10V voltage singal” can be made.
Setting Range (%) 25~100
■ Adjustable Range (full scale value)
· Analog output voltage : Analog output voltage×Percentage set with P149
(V)
10
(V)
10
Max. output frequency
150% of the rated output current
2.5
2.5
Output frequency Output current
Relationship between analog output voltage and output frequency when P149=100.
Relationship between analog output voltage and output frequency when P149=25.
182
Appendix Function Parameter List
P201
Load Rating
Load rating types are set as the rated output current reference.
Setting value
0
1
Details
Heavy load specification
Light load specification
· For applications where requires a small variation in torque or small maximum torque and maximum speed, please select “1: Light Load
Specification” to enable the motor to operate continuously at a high output level (however, the carrier frequency should be 5kHz or less).
· The light load specification can be used when the rated output current is larger than the heavy load specification, overload current ratings are listed as below.
【 Overload Current Ratings】
Heavy load specification: 150% of the rated output current, lating for 1 minute
Light load specification: 120% of the rated output current, lating for 1 minute
· The heavy load specification has no difference with the light load specification when the carrier frequency is above 7.5kHz.
· Please carefully read Item 7 in this manual for the rated output currents of the heavy load specification and light load specification of various models and use them in their rating range.
· For applications where there is a sharp variation in torque and an instantaneous sharp increase in torque, please select “0: heavy load specification”.
If the light load specification is selected, the inverter will be forced to make a stop due to the protection function.
183
Appendix Function Parameter List
P202
Auto-tuning
Measure the motor constants used for control purpose and automatically save them to parameter P208 to P212 (the 2nd motor: P216 to P220)
The inverter will automatically drive the motor within the range of the upper frequency limit and the lower frequency limit after the auto-tuning starts.
Do not start an auto-tuning if there is a danger with the motor that is being driven.
Never approach the motor and the conductive parts during auto-tuning.
Failure to do so may result in injury and accidents.
Setting value Details
· When operating in the sensorless vector control mode, or operating the auto torque boost in the V/F control mode, be sure to perform the auto-tuning for all motores before their first operation.
Otherwise, they cannot be controlled normally.
· Do not connect loads and other objects to the motor shaft during auto-tuning.
It is suggested that it should be done in the standalone status.
The auto-tuning cannot be normally performed if loads and objects with greater inertia are connected.
Perform the auto-tuning in a free rotation state without loads as far as possible.
· Start the auto-tuning only after the motor had come to a complete stop.
· Refer to “4.14 Auto-tuning” for the auto-tuning procedures.
184
Appendix Function Parameter List
P203
P204
P205
P206
P207
Motor Capacity
Motor Pole Number
Rated Voltage of Motor
Rated Frequency of Motor
Rated Current of Motor
Motor specifications are set as the benchmarks for motor auto-tuning.
■ Parameter P203
Data setting range(kW) 0.2, 0.4, 0.7, 1.5, 2.2, 3.7, 5.5, 7.5, 11, 15
P203: The setting range of motor capacity is limited by the rated values of the inverter.
■ Parameter P204
Data setting range (poles) 2, 4, 6
■ Parameter P205
0~500 Data setting range (V)
■ Parameter P206
10.0~120.0 Data setting range (Hz)
■ Parameter P207
Data setting range (A) 0.01~99.99
· Set specifications for the motor used.
· These setting values shall be taken as benchmarks for auto-tuning, please make such setting before the start of auto-tuning (parameter P202).
· The specifications of motor are defined by the combination of various rated voltages, rated frequencies amd rated currents.
【 For example】380V/50Hz/1.0A; 400V/60Hz/1.5A
The rated voltage should be set after the AC power voltage actually used to input voltage to the MK300 inverter had been selected.
· In addition, be sure to set the rated current based on the combination due to that the rated current varies with the different rated voltage and rated frequency.
Torque limitation (parameter P215) is conducted according to the internal arithmetic of the setting value of rated current of motor (P207). The limitation operation cannot be normally performed if the setting value of P207 is incorrect.
Related parameters: P202, P215
185
Appendix Function Parameter List
P208
P209
P210
P211
P212
Primary Resistance
Secondary Resistance
Energizing Inductance
Leakage Inductance
Energizing Current
Motor constants shall be saved after the auto-tuning is done.
■ Parameter P208
Data setting range(Ω) 0.00~99.99
■ Parameter P209
Data setting range(Ω) 0.00~99.99
■ Parameter P210
Data setting range(mH) 0.0~5000
■ Parameter P211
Data setting range(mH) 0.0~999.9
■ Parameter P212
Data setting range (A) 0.01~99.99
· Various motor constants shall be automatically saved after the auto-tuning
(parameter P202) is done.
· In principle, the values saved after the auto-tuning can be used directly.
Related parameters: P202
186
Appendix Function Parameter List
P213
P214
Speed Control Percentage Increment
Speed Control Integral Increment
Set the speed control increment for the internal arithmetic of sensorless vector control.
■ Parameter P213
Data setting range 0.01~10.00
■ Parameter P214
Data setting range 0.01~10.00
· Applicable initial values of various motors had been set. Normally, such initial values can be used directly.
· In the actual operation in sensorless vector control mode, adjustment to such parameter can sometimes enhance the stability and responsiveness to the torque variation.
Adjust the values in small increments during parameter adjustment and verify their effectiveness through actual running test.
· The adjustment of such parameter will cause the normal rotation control unable to be maintained when some values are applied.
When adjusting parameters, please conduct the test by taking into account the safety in case of abnormal rotation.
187
Appendix Function Parameter List
P215
Torque Limit Level
Set the limit value for torque current in the sensorless vector control mode.
Data setting range (%) 50~400
· The inverter will be forced to come to stop because of the protection function if the torque current increases due to that the torque is too large.
Therefore, it is necessary to set a limit value for the torque current to prevent the force stop.
· The output frequency shall be automatically changed for the control when the torque current reaches the limit value.
· To disable the limitation, please set the upper limit value to “400”.
· If it is required to prevent a force stop to the utmost extent, it is suggested to set the limit value to 200 or less.
The increase of the limit value are likely to cause it to reach the force stop level before the implementation of such limitation.
· Such torque limitation is conducted according to the internal arithmetic of the setting value of rated current of motor (P207). The limitation operation cannot be normally performed if the setting value of P207 is incorrect.
Related parameters: P207
188
Appendix Function Parameter List
P216
P217
P218
P219
P220
Capacity of the 2nd Motor
Pole Number of the 2nd Motor
Rated Voltage of the 2nd Motor
Rated Frequency of the 2nd Motor
Rated Current of the 2nd Motor
Motor specifications used as benchmarks for the auto-tuning of the 2nd motor are set via these parameters.
■ Parameter P216
Data setting range(kW) 0.2, 0.4, 0.7, 1.5, 2.2, 3.7, 5.5, 7.5, 11, 15
■ Parameter P217
Data setting range (poles) 2, 4, 6
P216: The setting range of capacity of the 2nd motor is limited by the rated values of the inverter.
■ Parameter P218
Data setting range (V)
■ Parameter P219
0~500
Data setting range (Hz) 10.0~120.0
■ Parameter P220
Data setting range (A) 0.01~99.99
· Set specifications for the 2nd motor used.
· These setting values shall be taken as benchmarks for auto-tuning, please make such setting before the start of auto-tuning (parameter P202) of the
2nd motor.
· The specifications of motor are defined by the combination of various rated voltages, rated frequencies amd rated currents.
【 For example】380V/50Hz/1.0A; 400V/60Hz/1.5A
The rated voltage should be set after the AC power voltage actually used to input voltage to the MK300 inverter had been selected.
In addition, be sure to set the rated current based on the combination due to that the rated current varies with the different rated voltage and rated frequency.
· Torque limitation of the 2nd motor (parameter P228) is conducted according to the internal arithmetic of the setting value of rated current of the 2nd motor (P220).
The limitation operation cannot be normally performed if the setting value of P220 is incorrect.
Related parameters: P202, P228
189
Appendix Function Parameter List
P221
P222
P223
P224
P225
Primary Resistance of the 2nd Motor
Secondary Resistance of the 2nd Motor
Energizing Inductance of the 2nd Motor
Leakage Inductance of the 2nd Motor
Energizing Current of the 2nd Motor
Motor constants of the 2nd motor shall be saved after the auto-tuning of the
2nd motor is done.
■ Parameter P221
Data setting range(Ω)
■ Parameter P222
0.00~99.99
Data setting range(Ω)
■ Parameter P223
0.00~99.99
Data setting range(mH) 0.0~5000
■ Parameter P224
Data setting range(mH) 0.0~999.9
■ Parameter P225
Data setting range (A) 0.01~99.99
· Various motor constants shall be automatically saved after the auto-tuning
(parameter P202) of the 2nd motor is done.
· In principle, the values saved after the auto-tuning can be used directly.
Related parameters: P202
190
Appendix Function Parameter List
P226
P227
Speed Control Percentage Increment of the 2nd Motor
Speed Control Integral Increment of the 2nd Motor
Set the speed control increment of the 2nd motor for the internal arithmetic of sensorless vector control.
■ Parameter P226
Data setting range 0.01~10.00
■ Parameter P227
Data setting range 0.01~10.00
· Applicable initial values of various motors had been set. Normally, such initial values can be used directly.
· In the actual operation in sensorless vector control mode, adjustment to such parameter can sometimes enhance the stability and responsiveness to the torque variation.
Adjust the values in small increments during parameter adjustment and verify their effectiveness through actual running test.
· The adjustment of such parameter will cause the normal rotation control unable to be maintained when some values are applied.
When adjusting parameters, please conduct the test by taking into account the safety in case of abnormal rotation.
191
Appendix Function Parameter List
P228
Torque Limit Level of the 2nd Motor
Set the limit value for torque current of the 2nd motor in the sensorless vector control mode.
Data setting range (%) 50~400
· The inverter will be forced to come to stop because of the protection function if the torque current increases due to that the torque is too large.
Therefore, it is necessary to set a limit value for the torque current to prevent the force stop.
· The output frequency shall be automatically changed for the control when the torque current reaches the limit value.
· To disable the limitation, please set the upper limit value to “400”.
· When it is required to prevent a force stop to the utmost extent, it is suggested to set the limit value to 200 or less.
The increase of the limit value are likely to cause it to reach the force stop level before the implementation of such limitation.
· Such torque limitation is conducted according to the internal arithmetic of the setting value of rated current of the 2nd motor (P220).
The limitation operation cannot be normally performed if the setting value of
P220 is incorrect.
Related parameters: P220
192
Appendix Function Parameter List
P301
Multi-step speed Function Selection
Each control function can be set when using parameter P101 to P106 to set
SW1 to SW6 to be used as multi-step speed functions.
Setting value
0
Details
Set to “multi-step speed frequency operation”
1
2
Set to “2nd/3rd/4th acceleration/deceleration operation”
Set to “acceleration/deceleration linked with multi-step speed frequency operation”
Set to “timer controlled multi-step speed frequency operation” 3
4
Set to “timer controlled acceleration/deceleration linked with multi-step speed frequency operation”
If the setting value is “0” to “2”, SW1 to SW6 can only be used after they have been set to “multi-step speed function” via parameter P101 to P106.
If the setting value is “3” or “4”, SW1 to SW6 are invalid even if they have been set to “multi-step speed function” via parameter P101 to P106.
Multi-step speed frequency operation (setting value = “0”)
The 2nd/3rd/4th acceleration/deceleration operation (setting value = “1”)
Acceleration/deceleration linked with multi-step speed frequency operation
(setting value = “2”)
■ Setting value = “0”: multi-step speed frequency operation
Up to 16 steps can be set by SW in multi-step speed frequency operation.
Acceleration/deceleration time is fixed to “the 1st Acceleration/Deceleration
Time” (parameter P001, P002).
When functions of SW1 to SW6 are all set to “1” and “r1” (multi-step speed SW input function), 4 SWs (starting from the one with the smallest No.) can be valid as multi-step speed command SW.
The 2nd to the 16th speed frequencies are set via parameter P302 to P316.
■ Setting value = “1”: The 2nd/3rd/4th acceleration/deceleration operation
When the frequency is fixed to the 1st speed, up to 4 acceleration/deceleration times can be changed through SW.
The 2nd to the 4th acceleration/deceleration times can be set via parameter
P317 to P322.
193
Appendix Function Parameter List
■ Setting value = “2”: Acceleration/deceleration linked with multi-step speed frequency operation
4 SWs can be used to link up to 16 speed steps and 4 acceleration/deceleration times to perform multi-step speed frequency operation.
SW1
(Note
1)
SW2
(Note
1)
SW3
(Note
1)
SW4
(Note
1)
ON
OFF
ON
OFF
OFF
ON
OFF
OFF multi-step speed frequency operation
Frequency
The 4th speed
The 5th speed
P301=0
Acceleration
/deceleration time
2nd/3rd/4th acceleration/deceleration operation
P302=1
Acceleration/deceleration linked with multi-step speed frequency operation
P303=2
Frequency
Acceleration
/deceleration time
The 1st acceleration
/deceleration
The 2nd acceleration
/deceleration
The 3rd acceleration
/deceleration
The 4th acceleration
/deceleration
Frequency
The 1st speed
The 2nd speed
The 3rd speed
The 4th speed
Acceleration
/deceleration time
The 1st acceleration
/deceleration
The 2nd acceleration
/deceleration
The 3rd acceleration
/deceleration
The 4th acceleration
/deceleration
The 5th speed
OFF ON ON OFF The 7th speed The 1st acceleration
/deceleration
The 1st speed
ON ON ON OFF The speed
The speed
The 7th speed
ON OFF OFF ON The 10th speed
ON ON
OFF OFF
OFF ON
ON ON
The 12th speed
The 13th speed
The 1st acceleration
/deceleration
The 10th speed The 1st acceleration
/deceleration
The 12th speed
The 13th speed
OFF ON ON ON The 15th speed The 15th speed
The 16th speed
(Note 1) When the functions of any 4 SWs of SW1 to SW6 are set to “1” and “r1”
(multi-step speed SW input function), the four SWs (starting from the one with the smallest No.) can be valid as multi-step speed command SW.
< Example > When SW1, SW2, SW4 and SW5 are set to multi-step speed SW input function, SW4 and SW5 will be allocated to the column (see Table above) previously occupied by SW3 and SW4.
194
Appendix Function Parameter List
■ Example of multi-step speed frequency operation (setting value = “0”)
Up to sixteen levels of frequency can be selected, switched and controlled by 4 button signals.
(The 1st speed: setting signal of P004, the 2nd to 16th speed: setting frequency of P302 toP316)
· Set any 4 buttons of SW1 to SW6 to multi-step speed function buttons.
(Set P101 to P106 to “1” or “r1”.)
· With this function, 1 button, 2 buttons and 3 buttons are used to input 2-step speed, 4-step speed and 8-step speed respectively.
· The inverter will stop (0 V stop) when the 2nd to 16th speed frequency (P302 to P316) are set to “0” and this multi-step speed frequency is selected.
195
196
Appendix Function Parameter List
■ Example of the 2nd/3rd/4th acceleration/deceleration operation (setting value = “1”)
Four groups of acceleration/deceleration times can be selected, switched and controlled with two SW signals.
(The 1st acceleration/deceleration time: P001 and P002, the 2nd to 4th acceleration/deceleration time: P317 to P322)
· Set any two buttons of SW1 to SW6 to multi-step speed function buttons.
(Set P301 to P306 to “1” or “r1”)
Appendix Function Parameter List
■ Example of Acceleration/deceleration linked with multi-step speed frequency operation (setting value = “2”)
The 2nd, 3rd and 4th speed can be linked (combined) with the 2nd, 3rd and 4th acceleration/deceleration by using two SW signals.
· Set any two buttons of SW1 to SW6 to multi-step speed function buttons.
(Set P101 to P106 to “1” or “r1”)
· The 1st speed is the command value of frequency setting signal set via parameter P004.
· The 1st acceleration time is set via parameter P001.
The 1st deceleration time is set via parameter P002.
· The 2nd to 16th speed frequency are set via parameter P302 to P316.
The 2nd to 4th acceleration/deceleration time are set via parameter P317 to
P322.
Related parameters: P101 to P106, P302 to P322
197
Appendix Function Parameter List
Timer controlled multi-step speed frequency operation (setting value = “3”)
Timer controlled acceleration/deceleration linked with multi-step speed frequency operation (setting value = “4”)
■ Setting Value = “3”: Timer controlled multi-step speed frequency operation
During timer controlled multi-step speed frequency operation, the acceleration/deceleration time can be fixed to 8 steps. Upon the input of the run command, the inverter will automatically switch to the next speed after running for a period of the time set.
When SW1 to SW6 are set to “multi-step speed SW input function”, even if signals are input during the timer controlled multi-step speed operation, such signals will be invalid and the multi-step speed operation will continue.
Rotation direction and continuous operation times of timer during one cycle can be set via parameter “P323: Rotation Direction of Timer Operation” and “P324: Continuous
Operation Times of Timer” respectively. Operation mode and waiting time for timer operation from the end of one cycle to the next one can be set via parameter “P325:
Continuous Operation Mode of Timer” and “P326: Continuous Waiting Time of Timer
Operation”. Runtime for the 1st to 8th speed can be set via parameter “P327 to P334: The
1st to 8th Speed Runtime”.
■ Setting Value = “4”: Timer controlled acceleration/deceleration linked with multi-step speed frequency operation
Up to 8 steps of speeds and 4 acceleration/deceleration times can be linked to perform the timer controlled mullt-speed operation.
P301=3
Rotation
Direction
(selected bit)
Forward run/
Reverse run
0/1
Forward run/
Reverse run
0/1
Forward run/
Reverse run
0/1
Forward run/
Reverse run
0/1
Forward run/
Reverse run
0/1
Forward run/
Reverse run
0/1
Forward run/
Reverse run
0/1
Forward run/
Reverse run
0/1
Frequency Runtime
The 1st speed
①
The 6th speed
⑥
The 7th speed
⑦
The 8th speed
⑧
The 2nd speed
②
The 3rd speed
③
The 4th speed
④
The 5th speed
⑤
The 1st speed runtime T1
The 2nd speed runtime T2
The 3rd speed runtime T3
The 4th speed runtime T4
The 5th speed runtime T5
The 6th speed runtime T6
The 7th speed runtime T7
The 8th speed runtime T8
Acceleration/ deceleration time
The 1st acceleration time A1
The 1st deceleration time D1
Rotation
Direction
(selected bit)
Forward run/
Reverse run
0/1
Forward run/
Reverse run
0/1
Forward run/
Reverse run
0/1
Forward run/
Reverse run
0/1
Forward run/
Reverse run
0/1
Forward run/
Reverse run
0/1
Forward run/
Reverse run
0/1
Forward run/
Reverse run
0/1
Frequency
The 5th speed
⑤
The 6th speed
⑥
The 7th speed
⑦
The 8th speed
⑧
The 1st speed
①
The 2nd speed
②
The 3rd speed
③
The 4th speed
④
P301=4
Runtime
The 1st speed runtime T1
The 2nd speed runtime T2
The 3rd speed runtime T3
The 4th speed runtime T4
The 5th speed runtime T5
The 6th speed runtime T6
The 7th speed runtime T7
The 8th speed runtime T8
Acceleration/ deceleration time
The 1st acceleration/ deceleration time
A1/D1
The 2nd acceleration/ deceleration time
A2/D2
The 3rd acceleration/ deceleration time
A3/D3
The 4th acceleration/ deceleration time
A4/D4
The 1st acceleration/ deceleration time
A1/D1
198
Appendix Function Parameter List
■ Example: Mode for one cycle of timer operation
After the timer runs one cycle for times set via parameter “P324: Continuous
Operation Times of Timer”, “tEnd” will be displayed. Then the timer will return to “0000” (operation status mode) after stop command is input with “tEnd” displayed.
· During timer operation, forward/reverse run commands input from operation panel, external control and communication are invalid.
· During timer operation, operation will be stopped immediately even in cycle operation when the stop command is input.
Related parameters: P001, P002, P101 to P106, P317 to 334
199
Appendix Function Parameter List
P302
P303
P304
P305
P306
The 2nd Speed
Frequency
The 3rd Speed
Frequency
The 4th Speed
Frequency
The 5th Speed
Frequency
The 6th Speed
Frequency
P307
P308
P309
P310
P311
The 7th Speed
Frequency
The 8th Speed
Frequency
The 9th Speed
Frequency
The 10th Speed
Frequency
The 11th Speed
Frequency
P312
P313
P314
P315
P316
The 12th Speed
Frequency
The 13th Speed
Frequency
The 14th Speed
Frequency
The 15th Speed
Frequency
The 16th Speed
Frequency
The 2nd to 16th speed frequency can be set to perform the multi-step speed operation.
Data setting range (Hz) 0.0·0.2~400.0
· “0.0” indicates 0V stop.
· When under vector control, the frequency is 0.5Hz to 120.0Hz.
Related parameters: P101 to P106, P301, , P317 to P334
P317
P318
The 2nd
Acceleration
Time
The 2nd
Deceleration
Time
P319
P320
The 3rd
Acceleration
Time
The 3rd
Deceleration
Time
P321
P322
The 4th
Acceleration Time
The 4th
Deceleration Time
The 2nd to 4th acceleration/deceleration time can be set to perform the 4-step acceleration/deceleration control operation.
The 2nd to 4th acceleration/deceleration time corresponds to the frequency band of 0.2 Hz to the max. output frequency.
Data setting range (s) 0.1~3600
Increment (s)
0.1(0.1~999.9)、
1(1000~3600)
Related parameters: P101 to P106, P301 to 304, P323 to P334
200
Appendix Function Parameter List
P323
Rotation Direction of Timer Operation
Rotation direction at each level from the 1st to 8th speed can be set in “P301:
Multi-step Speed Function Selection” with the setting value of “3” or “4”.
“0” and “1” indicate forward run and reverse run respectively, while the 1st to
8th speed indicate different levels. After rotation direction is determined (“0”
(forward run) or “1” (reverse run)), the sum of 0 or 1 multiplied by addition value corresponding to each level can be acquired and used as the setting value.
(Refer to the following table. The sum of rotation direction (“0” or “1”) multiplied by addition value of each speed level is used as the setting value.)
■ Example of setting: The 1st speed=forward run, the 2nd speed=forward run, the 3rd speed=forward run, the 4th speed=forward run, the 5th speed= reverse run, the 6th speed=reverse run, the 7th speed=reverse run, the 8th speed=forward run
Speed
Rotation direction
Set value
The 1st speed forward run
The
2nd speed forward run
The
3rd speed forward run
The 4th speed forward run
The 5th speed reverse run
The
6th speed reverse run
The 7th speed reverse run
The 8th speed forward run
0/1 0/1 0/1 0/1 0/1 0/1 0/1 0/1
Addition value
(0×1)+(0×2)+(0×4)+(0×8)+(1×16)+(1×32)+
(1×64)+(0×128)= 112
So the setting value is “112”.
· This function is only valid when “3” or “4” is set with “P301: Multi-step Speed
Function Selection”.
· Please note that rotation direction varies depending on the setting.
Related parameters: P001, P002, P301 to P308, P317 to P322
201
Appendix Function Parameter List
P324
Cntinuous Operation Times of Timer
Continuous operation times of timer in one cycle can be set by using the 1st to
8th speed operation as “timer operation cycle” when the setting is “3” or “4” in
“P301: Multi-step Speed Function Selection”.
Data Setting Range (times) 0·1~9999
* “0” indicates that there is no limit to operation times. After run command is input, the operation will keep on until stop command is input.
· This function is only valid when “3” or “4” is set with “P301: Multi-step Speed
Function Selection”.
· If data is changed during operation, the changed data will become valid from the next cycle.
Related parameters: P301, P325 to P326
202
Appendix Function Parameter List
P325
Continuous Operation Mode of Timer
P326
Continuous Waiting Time of Timer Operation
Operation mode and continuous waiting time of timer operation from the end of the 1st cycle to the 2nd cycle can be set when “3” or “4” is set with “P301:
Multi-step Speed Function Selection”.
If the continuous operation mode of timer is set to “1”, the continuous waiting time of timer operation will become invalid.
■ Parameter P325: Continuous Operation Mode of Timer
Setting value Details
0
After one cycle of operation, the operation returns to the 0 V stop status within the 1st deceleration time and enters the next cycle.
1
After one cycle of operation, the operating frequency will change to the 1st speed frequency of the next cycle within the 1st deceleration time.
■ Parameter P326: Continuous Waiting Time of Timer Operation
Data setting range (s) 0.0·0.1~6553
Increment (s)
0.1(0.1~999.9)、
1(1000~6553)
* “0.0” indicates that there is no waiting time.
· If mode is changed during operation, the changed mode will become valid from the next cycle.
· If data is changed during the waiting time, the changed data will become valid from the next cycle.
Related parameters: P002, P301 to P308, 317 to P324
203
Appendix Function Parameter List
P327
P328
P329
P330
The 1st Speed Runtime
The 2nd Speed Runtime
The 3rd Speed Runtime
The 4th Speed Runtime
P331
P332
P333
P334
The 5th Speed Runtime
The 6th Speed Runtime
The 7th Speed Runtime
The 8th Speed Runtime
Runtime at the 1st to 8th speed frequency can be set when “3” or “4” is set with
“P301: Multi-step Speed Function Selection”.
Data setting range (s) 0.0·0.1~6553
Increment (s)
0.1(0.1~999.9)、
1(1000~3600)
* “0.0” indicates that no operation will be performed at the set speed.
· Each function is only valid when “3” or “4” is set with “P301: Multi-step Speed
Function Selection”.
· The inverter will not operate at the set speed when the setting is “0.0”. Timer controlled multi-step speed operation will be performed only at the speed for which time is set with P327 to P334.
If data is changed during operation, the changed data will become valid from the next cycle.
Related parameters: P301 to P308, P317 to P326
204
Appendix Function Parameter List
P335
Winding Mode Control Selection
Select ON status for the winding mode control operation and the amplitude during such control.
Setting
0
Details
Winding mode control is OFF.
1
2
Amplitude is set based on the setting frequency.
Amplitude is set based on the maximum frequency.
P336
Amplitude in Winding Mode
Frequency amplitude under winding mode control can be set via this parameter.
Setting Range (%) 0.0~100.0
When P335=1, frequency amplitude (Hz) = setting frequency (Hz) × amplitude in winding mode (%)
When P335=2, frequency amplitude (Hz) = maximum frequency (Hz) ×amplitude in winding mode (%)
For the details of the winding mode control function, please refer to P335.
P337
Recoil Frequency Band Width in Winding Mode
Percentage of the recoil frequency for frequency amplitude set via parameter P336 can be set via this parameter.
Setting Range (%) 0.0~100.0
P338
Winding Mode Cycle
P339
Rise Time Coefficient of Winding Mode
Time required for one cycle of winding mode control operation and the acceleration time in one cycle can be set via these parameters.
■ Winding Mode Cycle
Setting range (sec) 0.0~3600
■ Rise Time Coefficient of Winding Mode
Setting Range (%) 0.0~100.0
The formulas of acceleration/deceleration time below can be acquired via the setting of
P338 and P339.
Rise time of triangular-wave frequency = winding mode cycle (s) × rise time coefficient of winding mode (%)
Drop time of triangular-wave frequency = winding mode cycle (s) × (100 - rise time coefficient of winding mode (%))
205
Appendix Function Parameter List
P340
Winding Mode Operation Selection
It is used for setting the winding mode operation selection.
Setting value Name
1 2-point normal mode
3 2-point random mode
■ Random Mode
When “P340: Winding Mode Operation Selection” is set to “2” or “3”, the winding mode is a random mode. And the rise time shall swing between “P341:
Max.Random Rise Time” and “P342: Min.Random Rise Time”.
■ 2-point Mode
When “P340: Winding Mode Operation Selection” is set to “1” or “3”, and “P344:
Winding Stop Length” is not set to “0”, the winding mode is a 2-point mode. In this case, the setting frequency will vary with the increase of the winding length and finally become “P302: The 2nd Speed Frequency”
Especially, when P340 is set to “3”, namely the 2-point mode is selected, in this case, the base frequency will change from the setting frequency to the 2nd speed frequency (P344 is not set “0”) with the change of the winding length, at the same time, the rise time coefficient will vary in a random range.
206
Appendix Function Parameter List
P341
Max. Random Rise
Time Coefficient
P342
Min. Random Rise Time
Coefficient
Set the maximum and minimum values of rise time for random function.
Setting Range (%) 0.0~100.0(setting unit: 0.1%)
P343
Winding Length Multiplier
When function of SW input pulse for winding length counts is set, the winding length can be calculated based on “P343: Winding Length Multiplier”.
Setting range 1~9999
P344
Winding Stop Length
The winding mode will stop when the winding length accumulates to the stop length.
Setting range (m) 0·1~600000(setting unit: 1m)
· The winding length stop function will be disabled when the setting value is
“0”.
· The relationship between the setting value and the display is as follows.
When the setting value is “1m
~
9,999m” , it will display “1
~
9999”.
When the setting value is “10,000m
~
99,999m”, it will display “1.000
~
9.999”
When the setting value is “100,000m ~ 600,000m”, it will display “10.00
~
60.00”.
207
Appendix Function Parameter List
PID control is a control method enabling the feedback value (measured value) to be consistent with the set target value. In MK300, PID control can be applied after the setting values of P118, P101 to P106 are changed to “10(r10)”. Related parameters of PID control: P345 to P356.
■ P Control (Proportional Control)
Output the operation amount (output frequency) that is in direct proportion to the deviation.
■ I Control (Integral Control)
Output the operation amount (output frequency) of the deviation integral. Which can be used to effectively control the consistence of the feedback value and the target value, however, a sharp change cannot be traced.
■ D Control (Derivative Control)
It is controlled via the value, which is obtained by derivative (slope deviation) multiplied by the time constant, to judge the deviation of the signal. Transient characteristics such as overshoot or vibration can be reduced through the derivative control.
■ PID Control Flow Chart
PID target value (SP)
P348: PID
P348: PID偏置值
Invalid: PID control switch signal = ON
Valid: PID control switch signal = OFF
(P101 to P106 = 10)
Frequency command value (set with P004)
(P345 = 0)
P345: PID target value
(P345 = 0.1~100.0%)
PID measured value (PV)
The 2nd analog input signal (set with P119 )
+
-
Deviation
(P118 = 1 or 2)
0
(P118 = 0)
PID arithmeticn
K p
( 1
T i
1
S
T d
S )
P349: proportional gain [Kp]
P350: integral time [Ti]
P349: derivative time [Td]
P349: control cycle [Ts]
+
+
PID output
P354: PID output reverse characteristic
P347: PID lower limit
P355: sleep mode operation frequency
+
-
P346: PID upper limit Invalid
Valid
P356: sleep mode operation delay
Operation amount
(output frequency)
Output
ON/OFF
P345
PID Target Value
Target value used in PID control can be set via this parameter. When the setting value is “0.0”, the frequency setting signal set with P004 shall be used as the target value.
Data setting range[%] 0.0, 0.1~100.0
P346
PID Upper Limit
Set the value obtained from the PID arithmetic not exceeding the setting value.
Set “P012: Max. Output Frequency” to “100%”.
Data setting range[%] 0.0~100.0
208
Appendix Function Parameter List
P347
PID Lower Limit
Set the value obtained from the PID arithmetic not lower than the setting value.
Set “P012: Max. Output Frequency” to “100%”.
Data setting range[%] 0.0, 0.1~100.0
P348
PID Bias
Bias corresponding to the PID output can be adjusted via this parameter. Set
“P012: Max. Output Frequency” to “100%”.
Data setting range[%] -100~100.0
P349
PID Proportional Gain(Kp)
Proportional gain used in PID arithmetic can be set via this parameter.
The larger the setting value is, the smaller the deviation is, however, instability phenomenon such as vibration will be produced if it is too large.
The smaller the setting value is, the larger the deviation between the target value (SP) and the measured value (PV) is.
Data setting range 0.1~1000
P350
PID Integral Time (Ti)
Integral time (time constant for integral computation) used in PID arithmetic can be set via this parameter.
If the deviation cannot be reduced to zero through proportional control, then this parameter must be set to eliminate the deviation.
It can quickly reach a stable status by shortening the integral time, however, overshoot or vibration will occur if the setting time is too short.
Data setting range[sec] 0.00, 0.01~360.0
※ “0.00” indicates that there is no proportional control.
P351
PIDDerivative Time (Td)
Derivative time used in in PID arithmetic can be set
The larger the setting value is, the greater the responsiveness is, but vibration will be produced accordingly. The decrease of the setting value can inhibit the overshoot, but on the other hand, the responsiveness will be weakened.
Data setting range[sec] 0.00, 0.01~10.0
※ “0.00” indicates that there is no proportional control.
209
Appendix Function Parameter List
P352
PID Control Cycle (Ts)
Execution cycle required in PID control can be set.
Data setting range[sec] 0.00, 0.01~60.0
P353
PID Output Characteristics
Forward or reverse operation output from PID arithmetic can be set via this parameter.
Setting value Details
■ Reverse Operation
Increase the operation amount (output frequency) if the deviation (SP-PV) is positive; decrease the operation amount if the deviation is negative.
<Example> Heating
Deviation >0, operation amount (output frequency) Cold operation amount UP
PID target value (SP)
+
-
PID measured value (PV)
Deviation <0, operation amount (output frequency) Hot operation amount DOWN
■ Forward Operation
Increase the operation amount (output frequency) if the deviation (SP-PV) is negative; decrease the operation amount if the deviation is positive.
<Example> Cooling
PID target value (SP)
+
-
PID measured value (PV)
Deviation <0, operation amount (output frequency)
Deviation > 0, operation amount (output frequency)
Hot operation amount UP
Undercolling operation amount
DOWN
P354
PID Output Reverse Selection
Set whether the rotation direction can be reversed or not when the PID output is negative.
Setting range
0
1
Reverse operation is disabled.
Reverse operation is enabled.
Details
Set the output frequency to “0”, when PID output
< 0.
Perform the reverse operation according to the output value when PID output <0.
· It is invalid when P118=2.
210
Appendix Function Parameter List
P355
Sleep Mode Operation Frequency
P356
Sleep Mode Operation Delay
■ Parameter P355: Sleep Mode Operation Frequency
Data setting range (Hz) 0.0•0.2~400.0
■ Parameter P356: Sleep Mode Operation
Data setting range (s) 0.0~25.0
When output frequency < sleep mode operation frequency is set,
The inverter will stop the output after the elapse of the sleep mode operation delay.
When output frequency > sleep mode operation frequency is set,
The output will be resumed after the elapse of the sleep mode operation delay.
Output frequency
Sleep mode operation frequency
Run command
RUN STOP RUN
Sleep mode operation delay
Sleep mode operation delay
P357
Speed Search Selection at Startup
To set whether the speed search is enabled or disabled at the startup.
Setting
0
1
Details
Speed search at startup is disabled.
When speed search is selected via parameter “P101 to P106: SW1 to
SW6 Function Selection”, speed search will be performed if relevant SWs are turned ON.
Speed search at startup is enabled.
· It is disabled in sensorless vector control mode.
211
Appendix Function Parameter List
P359
Waiting Time for Speed Search
The time to start the speed search can be set via this parameter during speed search.
Setting range 0.0~100.0
· If “P033: Waiting Time” is set and the waiting time has elapsed, the inverter will enter the waiting status according to the setting value of “Waiting Time for Speed Search” and then start the speed search.
P360
Voltage Recovery Time for Speed Search
The voltage can be applied gradually at the frequency detected during speed search.
Setting range 0.1~10.0
· If the setting value is too low, overcurrent trip may occur.
P361
Speed Search Selection During Retry
When retry function is set to “enabled” via parameter “P029: Retry Function”, whether speed search is performed or not during retry after fault occurrence can be set via this parameter.
Setting Details
0
1
Disabled: speed search is not performed during retry after fault occurrence.
Enabled: speed search is performed during retry after fault occurrence.
· It is disabled in sensorless vector control mode.
P362
Speed Search Retry Selection
Whether speed search is performed again after speed search selection failure can be set via this parameter.
Setting
0
1
Details
When speed search fails or the upper limit of retry times for speed search is exceeded, “SEr” will be displayed on the operation panel and operation will be stopped.
When speed search fails or upper limit of retry times for speed search is exceeded, operation will start at the start frequency.
212
Appendix Function Parameter List
P363
Speed Search Retry Times
Speed search retry times can be set when “Speed Search Retry Selection” is selected.
Setting Range (times) 0~10
P364
Upper Limit Frequency Selection for Speed Search
Frequency range for speed search can be set via this parameter.
Setting
0
1
Details
Speed search is performed at a frequency below the maximum frequency.
Speed search is performed at a frequency lower than the previous frequency operating before the normal stop of the operation.
213
“Administrative Measures on the Control of Pollution
Caused by Electronic Information Products” in China
Names and Content Marks of Toxic and Hazardous
Substances or Elements
Component name
Lead
(Pb)
Toxic and Hazardous Substances or Elements
Mercury
(Hg)
Cadmium
(Cd)
Hexavalent
Chromium
(Cr6+)
Polybrominated
Biphenyl
(PBB)
Polybrominated
Diphenyl
Ethers
(PBDE)
Base plate assembly
Case
×
○
○
○
○
○
○
○
○
○
○
○
Other accessories
○ ○ ○ ○ ○ ○
○: Indicates that the content of toxic or hazardous substances contained in all homogeneous materials for this component is below the standard specified in the “Requirements for
Concentration Limits for Certain Hazardous Substances in Electronic Information
Products”.
×: Indicates that the content of toxic or hazardous substances contained in at least one homogeneous material for this component is above the standard specified in
“Requirements for Concentration Limits for Certain Hazardous Substances in Electronic
Information Products”.
Note: This product accords with the EU RoHS Directive.
Items that comply not with the EU RoHS Directive are listed in the above
Table.
TYPE 1
214
Precautions on European Standard Directives
1. CE Marking labeled on the inverter is based on the following specifications directive.
Council directive :
2006/95/EC Low Voltage Directive
2011/65/EU RoHS Directive
Harmonized Standards :
EN61800-5-1 : 2007 Second Edition
EN50581 : 2012
2. Adaptability to EMC Directive shall be determined in a complete plant equipped with the inverter.
3. Inverter's control circuit terminals are only basically insulated (protection against electric shock I, overvoltage category II, pollution degree 2).
To meet requirements of CE Marking, final product shall be subject to insulation.
4. Make sure to ground the supply neutral.
5. Power supply input end of the inverter shall be equipped with protection devices for over current, short circuit and leakage of electricity.
6. Main circuit wiring (L, N, U, V, W) shall be connected with ring-type compression terminals.
7. The inverter is only used for fixed installation, not for other occasions.
8. Adaptability to Low Voltage Directive for the inverter
① Protection against Electric Shock: I
② Overvoltage category: II
③ Pollution degree: 2
9. The capacity of relay output terminal mark A, B, C is 30V DC, 0.3A.
10. Use the 2.5 mm 2 wire with the allowable continuous operating temperature up to 70°C for the grounding.
11. Ambient Temperature: 40°C maximum.
215
Precautions on European Standard Directives
1. CE Marking labeled on the inverter is based on the specifications of the Low
Voltage Directive.
2. Adaptability to EMC Directive shall be determined in a complete plant equipped with the inverter.
3. Inverter's control circuit terminals are only basically insulated (protection against electric shock I, overvoltage category II, pollution degree 2).
To meet requirements of CE Marking, final product shall be subject to insulation.
4. Make sure to ground the supply neutral.
5. Power supply input end of the inverter shall be equipped with protection devices for over current, short circuit and leakage of electricity.
6. Main circuit wiring (R/L1, S/L2, T/L3, U, V, and W) shall be connected with ring-type compression terminals.
7. The inverter is only used for fixed installation, not for other occasions.
8. Adaptability to Low Voltage Directive for the inverter:
① Protection against Electric Shock: I
② Overvoltage category: II
③ Pollution degree: 2
9. The capacity of relay output terminal mark A, B, C is 30V DC, 0.3A (resistive load).
10. Use the wire of a specified size with the allowable continuous operating temperature up to 70°C for the grounding.
11. Ambient Temperature: 40°C maximum.
216
Warranty
The products and specifications listed in this document are subject to change without prior notice as occasioned by the improvements that we introduce into our products. Therefore, when you consider the use of the product and place orders for the product, you may contact our customer service representatives and check that the details listed in this document are commensurate with the most up-to-date information.
We spare no efforts to give utmost care and attention to the quality of this product.
However, to ensure optimal performance, we recommend that:
1) When our product is used beyond the range of the specifications, environment or conditions listed herein, or it is used in any environment or conditions not listed herein, or when you are considering the use of product in any condition or environment that is not specified herein, or when you are considering the use of our product for particular purposes for which high reliability is required such as safety environment and control systems used for the railroad, aviation or medical care industries, you should contact our customer service representatives and obtain proper specification sheets. environment and conditions of use, installation locations etc. to prevent accidents caused by the items not listed herein.
3) Take safety measures (such as double interlock, etc.) to the external circuit of the product to ensure the safety of the whole system in case of abnormities caused by product failure or external factors; and always use this product within its limits and capacity mentioned in this document.
4) For the product you have purchased from us or with the product delivered to your premises, promptly perform an acceptance inspection; for handling of our product both before and during the acceptance inspection, give full attention to the control and preservation of our product.
【 Warranty Period】
• The warranty period of this product is 3 years from either the date of purchase or the date on which the product is delivered to the location specified by the Buyer.
However, the warranty period (the so-called “3 years”) shall be valid only until 42 months from the date of manufacture which includes a maximum of 6-month distribution period.
217
【 Warranty Scope】
• In the event of any failure or obvious defect in the product due to the reasons solely attributable to Panasonic Electric Works, Panasonic Electric Works shall remedy such malfunctioning or defective product at its own cost in one of the following ways: i) repair such product; ii) replace such product; iii) supply of replacement parts.
However, the warranty shall not cover the failures or defects arising from any of the following reasons.
1. Specifications, standards and handling procedures specified by the Buyer.
2. Modifications to the structure, performance or specifications performed by a party other than the Seller after the date of purchase or the date on which the product is delivered.
3. Phenomena that could not have been foreseen with the technology that was put into practical use at or after the time of purchase.
4. Cases that the range of conditions, circumstances or environment described in the manual or specification sheet are exceeded.
5. Damages that could be avoided if Buyer’s product provides the function and structure generally accepted in the industry when this product is incorporated into
Buyer’s product.
6. Natural disasters or force majeure.
7. Consumable goods such as capacitor, cooling fan and relay or optional accessories such as cables.
In addition, the warranty described herein shall only cover the single unit purchased or delivered by Panasonic Electric Works. Damages arising from failures or defects of this product are excluded from this warranty.
218
Revision History
The manual No. is recorded on the back co ver.
Issue Date
November 2014
Manual No.
MC-MK300SSC
Descriptions of Revision
The 1 st edition
Panasonic Industrial Devices SUNX Suzhou Co., Ltd.
No.97, Huoju Road, New District Suzhou, Jiangsu province, China
Phone: +86-512-6843-2580 FAX: +86-512-6843-2590
© Panasonic Industrial Devices SUNX Suzhou Co., Ltd. 2013
MC-MK300SSE
MC-MK300SSE
2014.11
device.panasonic.cn/ac
MK300
[Applicable models]
Three phase 400V(0.75kW~3.7kW)
다운로드
광고