Battery Model: D31T
Part Number: 8050-160
Nominal Voltage: 12 volts
NSN: 6140 01 457 5469
Description: High power, dual purpose engine start and deep cycle, sealed lead acid battery
Physical Characteristics:
Plate Design:
Electrolyte:
Case:
Color:
Group Size:
High purity lead-tin alloy. Wound cell configuration utilizing proprietary
SPIRALCELL
® technology.
Sulfuric acid, H
2
Polypropylene
SO
4
Case: Light Gray
Cover: “OPTIMA” Yellow
BCI: 31
Length:
Width:
Height:
Weight:
Standard Metric
12.774”
6.529”
9.355”
59.8 lb
324.46 mm
165.84 mm
237.62 mm (Height at the top of terminals)
27.1 kg
Terminal Configuration: 3/8”-16UNC-2A stainless steel stud.
Performance Data:
Open Circuit Voltage (Fully charged):
Internal Resistance (Fully charged):
Capacity:
Reserve Capacity:
13.1 volts
.0025 ohms
75 Ah (C/20)
BCI: 155 minutes
(25 amp discharge, 80°F (26.7°C), to 10.5 volts cut-off)
Power:
CCA (BCI 0°F): 900 amps
MCA (BCI 32°F): 1125 amps
Recommended Charging:
The following charging methods are recommended to ensure a long battery life: (Always use a voltage regulated charger with voltage limits set as described below.)
Model: D31T
These batteries are designed for starting and deep cycle applications and for use in vehicles with large accessory loads.
Recommended Charging Information:
Alternator:
Battery Charger (Constant Voltage):
Float Charge:
Rapid Recharge:
(Constant voltage charger)
Cyclic or Series String Applications:
13.65 to 15.0 volts
13.8 to 15.0 volts; 10 amps maximum; 6-12 hours approximate
13.2 to 13.8 volts; 1 amp maximum; (indefinite time at lower voltages)
Maximum voltage 15.6 volts. No current limit as long as battery temperature remains below 125°F (51.7°C). Charge until current drops below 1 amp.
14.7 volts. No current limit as long as battery temperature remains below 125°F (51.7°C). When current falls below 1 amp, finish with 3 amp constant current for 1 hour.
All limits must be strictly adhered to.
Recharge Time: (example assuming 100% discharge – 10.5 volts)
Current Approximate time to 90% charge
100 amps
50 amps
25 amps
52 minutes
112 minutes
210 minutes
Recharge time will vary according to temperature and charger characteristics. When using
Constant Voltage chargers, amperage will taper down as the battery becomes recharged. When amperage drops below 1 amp, the battery will be close to a full state of charge.
(All charge recommendations assume an average room temperature of 77°F (25°C).
Always wear safety glasses when working with batteries.
Always use a voltage regulated battery charger with limits set to the above ratings. Overcharging can cause the safety valves to open and battery gases to escape, causing premature end of life.
These gases are flammable! You cannot replace water in sealed batteries that have been overcharged. Any battery that becomes very hot while charging should be disconnected immediately.
Not fully charging a battery can result in poor performance and a reduction in capacity.
Shipping and Transportation Information:
OPTIMA batteries can be shipped by AIR. The battery is nonspillable and is tested according to
ICAO Technical Instructions DOC. 9284-AN/905 to meet the requirements of Packing Instructions
No. 806 and is classified as non-regulated by IATA Special Provision A-48 and A-67 for UN2800.
Terminals must be protected from short circuit.
BCI = Battery Council International