advertisement
HRM-4X Remote Station
Digital Partyline Solutions
Linking
People
Togethe
r
HRM-4X
Key Features and Benefits
• For use with the HMS-4X
HelixNet Main Station
• Access to all networked channels of audio from Main Station
• Select any 4 channels from up to
24 channels of audio
• Core Configuration Management
(CCM browser-based tool (with software v3.0 or higher)
• Large format yellow OLED,
10-character label displays
• Connects to Main Station over mic or Ethernet cable
• Powered by Powerline, PoE or
AC/DC adapter (universal)
• Rotary channel level controls
• Speaker and Program level controls
• Line/LAN Status indication
HelixNet is a digital partyline system with up to 24 channels of full-duplex audio and program audio over any shielded twisted-pair cable.
Description
The HRM-4X is a 1RU, 4-channel remote station that connects to the HMS-4X main station and other user stations using various cable types, including a single shielded twisted pair cable. The HRM-4X provides access to four simultaneous channels of intercom communication, plus assignable program audio.
Operation
The HRM-4X has separate buttons to activate the headset or the gooseneck mic.
User controls include OLED displays, momentary/latching Talk button, Call button and rotary encoder level controls per channel. Access to channels and other functions are assignable through the menu or the Core Configuration Manager (CCM) browser-based tool*.
Power Options
When using a combination of power options, the priority of power is applied; local power first, PoE second, then Powerline. The HRM-4X receives audio data, control data, and
DC power via the same Powerline cable connection to a HMS-4X Main Station.
*CCM is only available in software v3.0 and requires HLI-ET2 or HLI-FBS for access.
HRM-4X Remote Station
Digital Partyline Solutions
Technical Specifications
dBu is an absolute measurement. 0 dBu is referenced to 0.775 volts RMS.
Channels
Four local from any networked Main Station
One local and any networked program audio feeds (Assignable to intercom channels)
Connectors
Intercom Line: (1) 3-pin XLR-M (1) 3-pin XLR-F
Ethernet/PoE: Ethercon RJ-45
Headset: 4-pin XLR–M
Gooseneck Mic: 3-pin Tuchel
USB: Type A
Program: 3-pin XLR–F
SA (Stage Announce): 3-pin XLR–M
Hot Mic/IFB Interface: 1/4” (0.64 cm) phone jack
GPIO: 9 way D-type male (1xGPI, 1xGPO)
DC Power: 3-pin to AC adapter (provided)
Microphone Pre-amplifier
Headset Mic
Impedance: 200Ω (Dynamic)
Headset Mic Voltage: 1.7V (Electret selectable)
Limiter: +23dB
The following specified for a route to four-wire output at 0dBu out:
Mic Gain: 60dB (Dynamic), 45dB (Electret)
Frequency Response: 300Hz –
10 kHz ±3dBContoured for Intelligibility
Distortion: <0.2% THD @ 1kHz
Noise: <-55dBu (Dynamic),<-65dBu (Electret)
Headphone Amplifier
Load Impedance: >32Ω
Output Level: +12dBu before clipping
Sidetone: -12dBu (selectable)
The following specified for a route from a four-wire input at 0dBu in:
Max Gain: 0dB
Frequency Response: 180Hz – 11kHz +3dB
Distortion: <0.1% THD @ 1kHz
Noise: <-65dBu
Headphone Limiter: 0dBu (selectable)
Loudspeaker Amplifier
Load Impedance: 8Ω
Output Level: +18dBu before clipping
The following specified for a route from a four-wire input at 0dBu in:
Max Gain: 18dB
Frequency Response: 200Hz - 10kHz ±3dB
Distortion: <0.1% THD @ 1kHz
Noise:<-50dBu
Program Line Input
Maximum Level
Before Clipping: 18dBu
Nominal Input Level: 0dBu (selectable)
Input Impedance: >= 10KΩ
The following specified for a route to four-wire output at 0dBu out:
Frequency Response: 20Hz - 10kHz ±3dB
Distortion: <0.2% THD @ 1kHz
Noise: <-65dBu
Stage Announce Output
Maximum Level
Before Clipping: 18dBu
Nominal Output Level: 0dBu (selectable)
Output Impedance: <= 100Ω
The following specified for a route from a dynamic headset:
Frequency Response: 300Hz - 12kHz ±3dB
Distortion: <0.1% THD @ 1kHz
Noise: <-55dBu
Hot Mic Output
Maximum Level
Before Clipping: 12dBu
Nominal Output Level: 0dBu (selectable)
Output Impedance: <= 100Ω
The following specified for a route from a dynamic headset:
Frequency Response: 300Hz - 12kHz ±3dB
Distortion: <0.2% THD @ 1kHz
Noise: <-55dBu
Main Power (Remote Station)
Via AC Adapter:
Input Voltage Range: 100 - 240VAC
Input Frequency
Range: 50 - 60Hz
Input Power: <= 250VAC
AC Adapter Power
Connector: IEC60320-1-C14
Via Power over Ethernet (PoE):
Connector: RJ-45
Conforms to PoE standard: IEEE 802.3af-2003
Power Required: 13W
Environmental
Max temperature is 40ºC (104ºF)
0 - 90% relative humidity
Dimensions
19” W x 1.75” H x 6.4” D
(483 mm x 44 mm x 165 mm)
Weight
4lbs (1.8kg)
Order Code
HRM-4X www.clearcom.com
® Clear-Com and the Clear-Com logo are registered trademarks of HM Electronics, Inc. Copyright
© 2015. Clear-Com, LLC. All rights reserved.
Notice About Specifications
While Clear-Com makes every attempt to maintain the accuracy of the information contained in its product manuals, that information is subject to change without notice. Performance specifications included in this manual are design-center specifications and are included for customer guidance and to facilitate system installation. Actual operating performance may vary.
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project