DELL Force10 S60 Installation guide
Dell S60: a high-performance, stackable Layer 2 switch/Layer 3 router with 44 built-in 10/100/1000 Base-T ports, four SFP ports, and an optional SFP+ module. Ideal for demanding networking applications requiring high port density, flexibility, and scalability. Supports advanced features like stacking, jumbo frames, and comprehensive security options. Delivers reliable and efficient network connectivity for businesses of all sizes.
Advertisement
Advertisement
S60 Quick Start Guide
FTOS version 8.3.3.1
July 30, 2010
Copyright 2010 Force10 Networks
All rights reserved. Printed in the USA. January 2010.
Force10 Networks® reserves the right to change, modify, revise this publication without notice.
Trademarks
Force10 Networks® and E-Series® are registered trademarks of Force10 Networks, Inc. Force10, the Force10 logo, E1200, E600, E600i,
E300, EtherScale, TeraScale, FTOS, C-Series, and S-Series are trademarks of Force10 Networks, Inc. All other brand and product names are registered trademarks or trademarks of their respective holders.
Statement of Conditions
In the interest of improving internal design, operational function, and/or reliability, Force10 Networks reserves the right to make changes to products described in this document without notice. Force10 Networks does not assume any liability that may occur due to the use or application of the product(s) described herein.
Table of Contents
S60 Quick Start Guide 1
2 Table of Contents
Chapter 1 S60 Overview
This document is intended to aid you with quick installation and set-up of a new S60 system.
• For complete S60 installation information, including illustrations and display details, refer to Installing
the S60 System (included in the shipping box with the new chassis).
• For complete information regarding the configuration of the S60 and FTOS features, refer to the FTOS
Configuration Guide for the S60 and the FTOS Command Line Reference Guide for the S60.
Introduction
The Force10 Networks S60 is a high performance, high capacity, low cost, stackable, Layer 2 switch/Layer
3 router that supports 44 built-in 10/100/1000 Base-T ports, four SFP (small form-factor pluggable) ports, and an optional SFP+ module. The front of the S60 contains the Power Supply Units (PSUs), optional module slots and the grounding connectors. As shown in the rear panel of the S60 contains the 44 ethernet ports, optional module ports, the management ports and the displays for alarms and stacking identification.
Equipment
To successfully install the S60, ensure that you have the following:
• S60 chassis
• At least one grounded AC or DC power source per chassis
• Cable to connect the AC or DC power source to the chassis (US AC power cable included)
• Mounting brackets for rack installation (included)
• Screws for rack installation and #1#2 Phillips screwdrivers (not supplied)
• Ground cable (not supplied)
• Ground cable screws (included)
• copper/fiber cables
Other optional components are:
• Additional Power Supply Unit
• Additional Fan module
• Optional modules (if using)
S60 Quick Start Guide 1
2
Features
The S60 offers the following:
• S60 CPU and switch processor
• Stackable switch features
• 19-inch rack-mountable
• Standard 1U chassis height
• Integrated PSU/Fan module (3 fans per module)
• Hot Swappable optional modules, power supplies, and fan modules
• Up to 16K MAC address entries supported with hardware assisted aging
• Supports 9K jumbo frames
Ports
• Up to four optional SFP+ modules
• 44 fixed 10/100/1000 Mbps auto-sensing and auto MDIX RJ45 ports
• Four ports capable of using 100/1000 Base-T or 1000 Base-X using auto-media detect
• Optional ports supporting one 2-port 24G stacking module or two 1-port 12G stacking modules
• Console port
• USB-A port
• USB-B port
System status
S60 status information is viewed in several ways, including physical displays and boot menu options.
Status information is also seen through the CLI show commands and with SNMP traps. For details on those options, see the FTOS Command Reference for the S60 and the FTOS Configuration Guide for the
S60.
Refer to the S60 Installation Guide for details regarding the chassis physical displays.
S60 Overview
Chapter 2 Hardware Installation
This document is intended to aid you with quick installation and set-up of a new S60 system.
• For complete S60 installation information, including illustrations and display details, refer to Installing
the S60 System (included in the shipping box with the new chassis).
To install the S60 system, Force10 Networks recommends that you complete the installation procedures in the order presented below.
1
Install the S60 chassis in a rack or cabinet
a
b
Install chassis into rack or cabinet
2.
3.
4.
Supply power and power up the system
Attention: Always wear an ESD-preventive wrist or heel ground strap when handling the S60 and its components. As with all electrical devices of this type, take all the necessary safety precautions to prevent injury when installing this system. Electrostatic discharge (ESD) damage can occur if components are mishandled.
S60 Quick Start Guide 3
4
Install the S60 chassis in a rack or cabinet
Attach mounting brackets
The S60 is shipped with mounting brackets (rack ears) and required screws for rack or cabinet installation.
The brackets are enclosed in a package with the chassis. .
Note: Force10 recommends attaching the brackets to the front of the chassis, on the PSU side. This provides the greatest weight support for the chassis in the rack or cabinet, and is in compliance with
Bellcore Zone 4 earthquake requirements.
Step
1
2
Follow these steps to attach the brackets to the chassis:
Task
Take the brackets and screws out of their packaging.
Attach the brackets to the rear sides of the chassis, using four screws for each bracket. Attach the bracket so that the “ear” faces to the rear and the outside of the chassis.
Power Supply
View from chassis rear
Connect to rack/cabinet
(ear)
Screws
View of chassis front
Power Supply
Connect to rack/cabinet
(ear)
Hardware Installation
Step
1
2
Install chassis into rack or cabinet
Ensure that there is adequate clearance surrounding the rack or within the cabinet to permit access and airflow. If you are installing two S60 switches side-by-side, position the two chassis at least 5 inches (12.7 cm) apart to permit proper airflow. Follow the steps below to install a switch into a two-post 19-inch equipment rack, using the already attached mounting brackets.
Task
It is recommended that one person hold the S60 chassis in place while another attaches the brackets to the posts.
Attach the bracket “ears” to the rack or cabinet posts, using two screws for each bracket. Ensure the screws are tightened firmly.
PSU0
PSU1
Rack Mounting
"ears"
Rack/Cabinet
Post
Attach ground cable
The S60 is shipped with 2 10-32 screws for attaching a ground cable to the chassis. The cable itself is not included. Force10 recommends a 6AWG two-hole lug, #10 hole size, .63" spacing (not included in shipping) to properly ground the chassis. The two-hole lug must be a UL recognized, crimp-type lug.
Caution: Grounding conductors must be made of copper. Do not use aluminum conductors .
Step
1
Follow these steps to connect the ground cable to the chassis:
Task
Take the (2) 10-32 screws from the package.
S60 Quick Start Guide 5
Step
2
3
Task (Continued)
Cut cable to desired length. Cable length must facilitate the proper operation of fault interrupt circuits.
Force10 recommends using of the shortest cable route allowable.
Attach the two-hole lug to the chassis as shown, using the supplied screws.
Any un-plated mating surfaces should be brought to a shiny finish, and apply an anti-oxidant coating to the surfaces prior to mating. Plated mating surfaces must be clean and free from contamination.
1
2
4 Attach the other end of the ground cable to a suitable ground point.
Insert Optional Modules
The S60 system has expansion slots at the front left and the rear right of the chassis, that can be used for
SFP+ devices.The following table lists the modules that can be installed into these slots. The modules are hot-swappable; you can insert or replace modules without powering down the system
Module Description
2-port 10G SFP+ optical module
Catalog Number
S60-10GE-2S
6
Attention: Electrostatic discharge (ESD) damage can occur if components are mishandled. Always wear an ESD-preventive wrist or heel ground strap when handling the S60 and its components.
Step
5
To install an optional module, follow the steps below:
Task
Remove the faceplate covering the module slot located at the rear left or the front right of the S60.
Hardware Installation
Step
6
Task
Remove the module from its packaging and slide the module into the slot.
7 Secure the captive screw on the side of the module.
Install the SFP and SFP+ optics
The S60 has 4 SFP optical ports in the front of the chassis in addition to the optional SFP+ optical modules.
To install SFP or SFP+ optics into an open port, follow the steps below:
Attention: Electrostatic discharge (ESD) damage can occur if components are mishandled. Always wear an ESD-preventive wrist or heel ground strap when handling the S60 and its components.
Step
1
2
Task
Position the SFP or SFP+ so it is in the upright position. (The optic has a key that prevents it from being inserted incorrectly.)
Insert the optic into the port until it gently snaps into place.
S60 Quick Start Guide 7
8
Note: For details on Force10 Networks’ supported optics, refer to http://www.force10networks.com/ products/specifications.asp
Supply power and power up the system
Supply power to the S60 after they are mounted in a rack (or on a table) and the optional modules are installed.
Note: A US AC power cable is included in the shipping container for powering up an AC power supply. All other power cables must be ordered separately
Attention: Electrostatic discharge (ESD) damage can occur if components are mishandled. Always wear an ESD-preventive wrist or heel ground strap when handling the S60 and its components.
AC power
Connect the plug to each AC receptacle, making sure that the power cord is secure. As soon as the cable is connected between the S60 and the power source, the chassis is powered-up; there is no on/off switch.
DC power
Connect the cable to the DC receptacle at the rear of the S60, making sure that the power cord is secure.
When the cable is secured, turn the power switch on.
Hardware Installation
Chapter 3 Getting Started
This document is intended to aid you with quick installation and set-up of a new S60 system.
• For complete information regarding the configuration of the S60 and FTOS features, refer to the FTOS
Configuration Guide for the S60 and the FTOS Command Line Reference Guide for the S60.
The system then loads FTOS and boot messages scroll up the terminal window during this process. No user interaction is required if the boot process proceeds without interruption.
For details on using the Command Line Interface (CLI), see the Fundamentals chapter in the FTOS
Configuration Guide for the S60.
Console access
The S60 has 2 management ports available for system access: a serial console port and a USB-B port. The
USB-B ports acts exactly as the console port.
By default, the S60 sends system messages to the serial console port. However, only one console connection can be active at a time. When both the serial console port and the USB-B port are connected, the system defaults to the USB-B port. The console connection is considered inactive if the USB-B port is also connected.
You can switch between console connections by physically connecting or disconnecting the cables. A system message is displayed on the serial console prior to switching to the USB-B console. When the
USB-B cable is detached, the system returns to the serial console default.
Access the RJ45 console port (RS-232)
Note: Before starting this procedure, be sure you have a terminal emulation program already installed on your PC.
The RS-232 console port is labeled on the the S60 chassis. It is in the upper right-hand side, as you face the rear of the chassis.
S60 Quick Start Guide 9
Figure 1 S60 serial console port connector
Console
Port
Step
1
2
3
To access the console port, follow the procedures below. Refer to
Table 1 for the console port pinout.
Task
Install an RJ-45 copper cable into the console port. Use a rollover cable to connect the S60 console port to a terminal server.
Connect the other end of the cable to the DTE terminal server.
Default terminal settings on the console are set as follows:
• 9600 baud rate
• No parity
• 8 data bits
• 1 stop bit
• No flow control
10
Accessing the RJ-45 console port with a DB-9 adapter
You can connect to the console using an RJ-45 to DB-9 adapter along with the RJ-45 rollover cable if the
DTE has a DB-9 interface. Table 1
lists the pin assignments.
Table 1 Pin Assignments Between the E300 System Console and a DTE Terminal Server
E300 System
Console Port RJ-45 to RJ-45 Rollover Cable
Signal
RTS
NC
TxD
GND
GND
RxD
NC
CTS
RJ-45 pinout
6
7
4
5
8
1
2
3
RJ-45 Pinout
3
2
5
4
1
8
7
6
RJ-45 to DB-9
Adapter
DB-9 Pin
3
4
5
5
7
8
6
2
Terminal Server
Device
Signal
CTS
DSR
RxD
GND
GND
TxD
DTR
RTS
Getting Started
Access the USB-B console port
The S60 has 2 management ports available for system access: a console port and a USB-B port. The
USB-B ports acts exactly as the console port. The terminal settings are the same, and the S60 sends all messages to the USB-B drive when it is connected.
The USB-B connector port is labeled on the the S60 chassis. It is to the left of the management ports, as you face the rear of the chassis.
Figure 2 S60 USB-B port connector
USB-B
Port
When both the console port and the USB-B port are connected, the system defaults to the USB-B port. The console connection is considered inactive if the USB-B port is also connected.
Note: Before starting this procedure, be sure you have a terminal emulation program already installed on your PC. You will also require appropriate drivers for the USB device in use. Contact Force10 Networks
Technical Support for assistance.
Step
3
4
1
2
5
6
Task
Power on the PC (XP operating system recommended)
Connect the USB-A end of cable (supplied) into an available USB port on the PC
Connect the USB-B end of cable into the USB-B console port on the S60 (
Power on the S60.
Install necessary USB device drivers (internet connection required).
Contact Force10 Networks Technical Support for assistance if necessary.
Open your terminal software emulation program to access the S60.
S60 Quick Start Guide 11
Step
7
Task (Continued)
Using the terminal settings shown here, set the terminal connection settings.
• 9600 baud rate, No parity, 8 data bits, 1 stop bit, No flow control
8 The CLI command prompt appears (shown below) when you are connected to the S60.
12 Getting Started
Figure 3 Completed Boot Process
.*************.
.# #### #######.
######## ####### ######### ######## ######## .#. ###### ###########.
### ### ## ### ### #### ### .##. ## ### #### ###.
### ### ### ### ### ### ### *#. ### ### #*
### ### ## ### #### ### ######## *# -## ### #*
###### ### ## ######### ### ######## *# ### ## #*
### ### ## ### #### ### ### *# #### ### #*
### ### ### ### #### #### ### *#. #### ### ###*
### ### ### ### ### ##### ## ######## .#.##### #### #### .
### ##### ### ### ###### ######## .###### ############ .
.# ######### .
`************'
Copyright 1999-2006 Force10 Networks, Inc.
+ Force10 Networks, Inc.
+ CPU: DB-MV64460-BP/IBM750Fx (2.3)
+ Version: VxWorks5.5.1
+ Memory Size: 1038876672 bytes.
+ BSP Version: 1.2/1.3.6
+ Creation Date : Jan 2 2007 nvDrvInit: nvDrvErase passed
-> 00:00:10: %RPM0-U:CP %RAM-6-ELECTION_ROLE: RPM0 is transitioning to Primary RPM.
00:00:11: %RPM0-P:CP %CHMGR-2-FAN_BAD: Minor alarm: some fans in fan tray 0 are down
00:00:11: %RPM0-P:CP %CHMGR-5-CARDDETECTED: Line card 1 present
DSA Card Init
00:00:11: %RPM0-P:CP POEMGR-4-POE_POWER_USAGE_ABOVE_THRESHOLD: Inline power used is exceeded 90% o available inline power
00:00:12: %RPM0-P:CP %CHMGR-5-CARDDETECTED: Line card 2 present
00:00:12: %RPM0-P:CP %TSM-6-SFM_SWITCHFAB_STATE: Switch Fabric: UP
00:00:12: %RPM0-P:CP %TSM-6-SFM_FULL_PARTIAL_STATE: SW_FAB_UP_1 SFM in the system
00:00:13: %RPM0-P:CP %IFMGR-5-OSTATE_UP: Changed interface state to up: Ma 0/0
00:01:27: %RPM0-P:CP %CHMGR-5-CHECKIN: Checkin from line card 1 (type E48TB, 48 ports)
00:01:27: %RPM0-P:CP %CHMGR-5-CHECKIN: Checkin from line card 2 (type E48TB, 48 ports)
00:01:28: %RPM0-P:CP %CHMGR-5-LINECARDUP: Line card 1 is up
00:01:28: %RPM0-P:CP %CHMGR-5-LINECARDUP: Line card 2 is up
00:01:36: %RPM0-P:CP %RAM-5-RPM_STATE: RPM0 is in Active State.
00:01:36: %RPM0-P:CP %CHMGR-5-CHAS_READY: Chassis ready
00:01:37: %RPM0-P:CP %SEC-5-LOGIN_SUCCESS: Login successful for user on line console
Force10>
Default Configuration
A version of FTOS is pre-loaded onto the chassis, however the system is not configured when you power up for the first time (except for the default hostname, which is Force10). You must configure the system using the CLI, except when using Bare Metal Auto-Configuration. Refer to the Bare Metal
Auto-Configuration chapter in the FTOS COnfiguration Guide for the S60.
S60 Quick Start Guide 13
Note: If you are using the Bare Metal Auto-Configuration feature, you do not need to proceed with the following sections.
Configure a Host Name
The host name appears in the prompt. The default host name is force10 .
• Host names must start with a letter and end with a letter or digit.
• Characters within the string can be letters, digits, and hyphens.
To configure a host name:
Command Syntax hostname name
Step Task
1 Create a new host name.
illustrates the hostname command.
Figure 4 Configuring a Hostname
Default Hostname
Force10(conf)#hostname R1
R1(conf)#
New Hostname
Command Mode
CONFIGURATION
Access the System Remotely
You can configure the system to access it remotely by Telnet. The method for configuring the C-Series and
E-Series for Telnet access is different from S-Series.
• The C-Series and E-Series have a dedicated management port and a management routing table that is separate from the IP routing table.
• The S-Series does not have a dedicated management port, but is managed from any port. It does not have a separate management routing table.
Access the C-Series and E-Series and the S60 Remotely
Configuring the system for Telnet is a three-step process:
14 Getting Started
1. Configure an IP address for the management port. See
Configure the Management Port IP Address
.
2. Configure a management route with a default gateway. See Configure a Management Route
.
3. Configure a username and password. See
Configure a Username and Password
.
Configure the Management Port IP Address
Assign IP addresses to the management ports in order to access the system remotely.
To configure the management port IP address:
Step Task
1
2
3
Command Syntax
Enter INTERFACE mode for the
Management port.
interface ManagementEthernet slot/port
• slot range: 0 to 1
• port range: 0
Assign an IP address to the interface.
Enable the interface.
ip address ip-address/mask
• ip-address: an address in dotted-decimal format (A.B.C.D).
• mask: a subnet mask in /prefix-length format (/xx).
no shutdown
Command Mode
CONFIGURATION
INTERFACE
INTERFACE
Configure a Management Route
Define a path from the system to the network from which you are accessing the system remotely.
Management routes are separate from IP routes and are only used to manage the system through the management port.
To configure a management route:
Step Task
1
Configure a management route to the network from which you are accessing the system.
Command Syntax management route ip-address / mask gateway
• ip-address: the network address in dotted-decimal format (A.B.C.D).
• mask: a subnet mask in /prefix-length format (/xx).
• gateway : the next hop for network traffic originating from the management port.
Command Mode
CONFIGURATION
Configure a Username and Password
Configure a system username and password to access the system remotely.
S60 Quick Start Guide 15
16
To configure a username and password:
Step Task
1
Configure a username and password to access the system remotely.
Command Syntax username username password [encryption-type] password encryption-type specifies how you are inputting the password, is 0 by default, and is not required.
• 0 is for inputting the password in clear text.
• 7 is for inputting a password that is already encrypted using a Type 7 hash. Obtaining the encrypted password from the configuration of another Force10 system.
Command Mode
CONFIGURATION
Access the S-Series Remotely ( on a non-management port)
The S-Series does not have a dedicated management port nor a separate management routing table.
Configure any port on the S-Series to be the port through which you manage the system and configure an
IP route to that gateway.
Note: The S60 system uses management ports and can be configured similar to the C-Series and
E-Series systems. Refer to
Access the C-Series and E-Series and the S60 Remotely
.
Configuring the system for Telnet access is a three-step process:
1. Configure an IP address for the port through which you will manage the system using the command ip address from INTERFACE mode, as shown in
.
2. Configure a IP route with a default gateway using the command ip route from CONFIGURATION mode, as shown in
.
3. Configure a username and password using the command username from CONFIGURATION mode, as shown in
.
Getting Started
Figure 5 Configuring the S-Series for Remote Access
R5(conf)#int gig 0/48
R5(conf-if-gi-0/48)#ip address 10.11.131.240
R5(conf-if-gi-0/48)#show config
!
interface GigabitEthernet 0/48
ip address 10.11.131.240/24
no shutdown
R5(conf-if-gi-0/48)#exit
R5(conf)#ip route 10.11.32.0/23 10.11.131.254
R5(conf)#username admin pass force10
Configure the Enable Password
Access the EXEC Privilege mode using the enable command. The EXEC Privilege mode is unrestricted by default. Configure a password as a basic security measure. There are two types of enable passwords:
• enable password stores the password in the running/startup configuration using a DES encryption method.
• enable secret is stored in the running/startup configuration in using a stronger, MD5 encryption method.
Force10 recommends using the enable secret password.
To configure an enable password:
Task Command Syntax Command Mode
Create a password to access EXEC Privilege mode.
enable [password | secret] [ level level ] [ encryption-type ] password level is the privilege level, is 15 by default, and is not required.
encryption-type specifies how you are inputting the password, is 0 by default, and is not required.
• 0 is for inputting the password in clear text.
• 7 is for inputting a password that is already encrypted using a DES hash. Obtain the encrypted password from the configuration file of another Force10 system.
• 5 is for inputting a password that is already encrypted using an MD5 hash. Obtain the encrypted password from the configuration file of another Force10 system.
CONFIGURATION
Configuration File Management
Files can be stored on and accessed from various storage media. Rename, delete, and copy files on the system from the EXEC Privilege mode.
S60 Quick Start Guide 17
The E-Series EtherScale platform architecture uses MMC cards for both the internal and external Flash memory. MMC cards support a maximum of 100 files. The E-Series TeraScale and ExaScale platforms architecture use Compact Flash for the internal and external Flash memory. It has a space limitation but does not limit the number of files it can contain.
Note: Using flash memory cards in the system that have not been approved by Force10 can cause unexpected system behavior, including a reboot.
Copy Files to and from the System
The command syntax for copying files is similar to UNIX. The copy command uses the format copy
source-file-url destination-file-url .
Note: See the FTOS Command Reference for a detailed description of the copy command.
• To copy a local file to a remote system, combine the file-origin syntax for a local file location with the file-destination
syntax for a remote file location shown in Table 2 .
• To copy a remote file to Force10 system, combine the file-origin syntax for a remote file location with the file-destination syntax for a local file location shown in
.
Table 2 Forming a copy Command source-file-url Syntax destination-file-url Syntax
Local File Location
Internal flash: primary RPM standby RPM
External flash: primary RPM standby RPM
USB Drive (
USB drive on RPM0
External USB drive
Remote File Location
FTP server
TFTP server
SCP server copy flash://filename copy rpm { 0 | 1 } flash://filename copy rpm { 0 | 1 } slot0://filename copy rpm { 0 | 1 } slot0://filename copy rpm0usbflash://filepath copy usbflash://filepath flash://filename rpm { 0 | 1 } flash://filename rpm rpm
{ 0 | 1 } slot0://filename
{ 0 | 1 } slot0://filename rpm0usbflash://filename usbflash://filename copy ftp://username:password @{ hostip
| hostname }/ filepath / filename copy tftp: //{ hostip | hostname } /filepath/ filename copy scp:// { hostip | hostname } /filepath/ filename ftp://username:password @{ hostip | hostname }/ filepath / filename tftp: //{ hostip | hostname } /filepath/filename scp:// { hostip | hostname } /filepath/filename
18 Getting Started
Important Points to Remember
• You may not copy a file from one remote system to another.
• You may not copy a file from one location to the same location.
• The internal flash memories on the RPMs are synchronized whenever there is a change, but only if both RPMs are running the same version of FTOS.
• When copying to a server, a hostname can only be used if a DNS server is configured.
• The usbflash and rpm0usbflash commands are supported on E-Series ExaScale platform only.
Refer to the FTOS Release Notes for a list of approved USB vendors.
shows an example of using the copy command to save a file to an FTP server.
Figure 6 Saving a file to a Remote System
Local Location
Remote Location
Force10#copy flash://FTOS-SB-8.3.3.1.bin ftp://myusername:[email protected]//FTOS/FTOS-SB-8.3.3.1
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
27952672 bytes successfully copied
shows an example of using the copy command to import a file to the Force10 system from an FTP server.
Figure 7 Saving a file to a Remote System
Remote Location
Local Location
Force10#$//copy ftp://myusername:[email protected]//FTOS/FTOS-SB-8.3.3.1.bin flash://
Destination file name [FTOS-EF-8.3.3.1.bin.bin]:
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
26292881 bytes successfully copied
Save the Running-configuration
The running-configuration contains the current system configuration. Force10 recommends that you copy your running-configuration to the startup-configuration. The system uses the startup-configuration during boot-up to configure the system. The startup-configuration is stored in the internal flash on the primary
RPM by default, but it can be saved onto an external flash (on an RPM) or a remote server.
To save the running-configuration:
Note: The commands in this section follow the same format as those in
System on page 18 but use the filenames startup-configuration and running-configuration. These
commands assume that current directory is the internal flash, which is the system default.
S60 Quick Start Guide 19
20
Task Command Syntax
Save the running-configuration to: the startup-configuration on the internal flash of the primary
RPM the internal flash on an RPM copy running-config startup-config copy running-config rpm { 0|1 } flash://filename
Note: The internal flash memories on the RPMs are synchronized whenever there is a change, but only if the RPMs are running the same version of FTOS.
Command Mode
EXEC Privilege the external flash of an RPM an FTP server a TFTP server an SCP server copy running-config rpm { 0|1 } slot0://filename copy running-config ftp://
username:password @{ hostip | hostname } /
filepath/filename copy running-config tftp:// { hostip | hostname } /
filepath/filename copy running-config scp:// { hostip | hostname } /
filepath/filename
Note: When copying to a server, a hostname can only be used if a DNS server is configured.
copy running-config startup-config duplicate Save the running-configuration to the startup-configuration on the internal flash of the primary RPM. Then copy the new startup-config file to the external flash of the primary RPM.
EXEC Privilege
View Files
File information and content can only be viewed on local file systems.
To view a list of files on the internal or external Flash:
Step Task
1 View a list of files on: the internal flash of an RPM the external flash of an RPM
Command Syntax dir flash: dir slot:
Command Mode
EXEC Privilege
The output of the command dir also shows the read/write privileges, size (in bytes), and date of
modification for each file, as shown in Figure 8 .
Getting Started
Figure 8 Viewing a List of Files in the Internal Flash
Force10#dir
Directory of flash:
1 drw- 32768 Jan 01 1980 00:00:00 .
2 drwx 512 Jul 23 2007 00:38:44 ..
3 drw- 8192 Mar 30 1919 10:31:04 TRACE_LOG_DIR
4 drw- 8192 Mar 30 1919 10:31:04 CRASH_LOG_DIR
5 drw- 8192 Mar 30 1919 10:31:04 NVTRACE_LOG_DIR
6 drw- 8192 Mar 30 1919 10:31:04 CORE_DUMP_DIR
7 d--- 8192 Mar 30 1919 10:31:04 ADMIN_DIR
8 -rw- 33059550 Jul 11 2007 17:49:46 FTOS-EF-7.4.2.0.bin
9 -rw- 27674906 Jul 06 2007 00:20:24 FTOS-EF-4.7.4.302.bin
10 -rw- 27674906 Jul 06 2007 19:54:52 boot-image-FILE
11 drw- 8192 Jan 01 1980 00:18:28 diag
12 -rw- 7276 Jul 20 2007 01:52:40 startup-config.bak
13 -rw- 7341 Jul 20 2007 15:34:46 startup-config
14 -rw- 27674906 Jul 06 2007 19:52:22 boot-image
15 -rw- 27674906 Jul 06 2007 02:23:22 boot-flash
--More--
To view the contents of a file:
Step Task
1 View the: contents of a file in the internal flash of an RPM contents of a file in the external flash of an RPM running-configuration startup-configuration
Command Syntax Command Mode show file rpm { 0|1 } flash://filename show file rpm { 0|1 } slot0://filename EXEC Privilege show running-config show startup-config
View Configuration Files
you track the last time any user made a change to the file, which user made the changes, and when the file was last saved to the startup-configuration.
In the running-configuration file, if there is a difference between the timestamp on the “Last configuration change,” and “Startup-config last updated,” then you have made changes that have not been saved and will not be preserved upon a system reboot.
S60 Quick Start Guide 21
Figure 9 Tracking Changes with Configuration Comments
Force10#show running-config
Current Configuration ...
! Version 8.2.1.0
! Last configuration change at Thu Apr 3 23:06:28 2008 by admin
! Startup-config last updated at Thu Apr 3 23:06:55 2008 by admin
!
boot system rpm0 primary flash://FTOS-EF-8.2.1.0.bin
boot system rpm0 secondary flash://FTOS-EF-7.8.1.0.bin
boot system rpm0 default flash://FTOS-EF-7.7.1.1.bin
boot system rpm1 primary flash://FTOS-EF-7.8.1.0.bin
boot system gateway 10.10.10.100
--More--
File System Management
The Force10 system can use the internal Flash, external Flash, or remote devices to store files. It stores files on the internal Flash by default but can be configured to store files elsewhere.
To view file system information:
Task
View information about each file system.
Command Syntax show file-systems
Command Mode
EXEC Privilege
The output of the command show file-systems
) shows the total capacity, amount of free memory, file structure, media type, read/write privileges for each storage device in use.
Figure 10 show file-systems Command Example
Force10#show file-systems
Size(b) Free(b) Feature Type Flags Prefixes
520962048 213778432 dosFs2.0 USERFLASH rw flash:
127772672 21936128 dosFs2.0 USERFLASH rw slot0:
- - - network rw ftp:
- - - network rw tftp:
- - - network rw scp:
You can change the default file system so that file management commands apply to a particular device or memory.
To change the default storage location:
Task
Change the default directory.
Command Syntax cd directory
Command Mode
EXEC Privilege
In
Figure 11 , the default storage location is changed to the external Flash of the primary RPM. File
management commands then apply to the external Flash rather than the internal Flash.
22 Getting Started
Figure 11 Alternative Storage Location
Force10#cd slot0:
Force10#copy running-config test
Force10#copy run test
!
7419 bytes successfully copied
Force10#dir
Directory of slot0:
1 drw- 32768 Jan 01 1980 00:00:00 .
2 drwx 512 Jul 23 2007 00:38:44 ..
3 ---- 0 Jan 01 1970 00:00:00 DCIM
4 -rw- 7419 Jul 23 2007 20:44:40 test
5 ---- 0 Jan 01 1970 00:00:00 BT
6 ---- 0 Jan 01 1970 00:00:00 200702~1VSN
7 ---- 0 Jan 01 1970 00:00:00 G
8 ---- 0 Jan 01 1970 00:00:00 F
9 ---- 0 Jan 01 1970 00:00:00 F slot0: 127772672 bytes total (21927936 bytes free)
No File System Specified
File Saved to External Flash
View command history
The command-history trace feature captures all commands entered by all users of the system with a time stamp and writes these messages to a dedicated trace log buffer. The system generates a trace message for each executed command. No password information is saved to the file.
To view the command-history trace, use the show command-history command, as shown in Figure 487 .
Figure 12 Command Example show command-history
Force10#show command-history
[12/5 10:57:8]: CMD-(CLI):service password-encryption
[12/5 10:57:12]: CMD-(CLI):hostname Force10
[12/5 10:57:12]: CMD-(CLI):ip telnet server enable
[12/5 10:57:12]: CMD-(CLI):line console 0
[12/5 10:57:12]: CMD-(CLI):line vty 0 9
[12/5 10:57:13]: CMD-(CLI):boot system rpm0 primary flash://FTOS-CB-1.1.1.2E2.bin
Upgrading and Downgrading FTOS
Note: To upgrade or downgrade FTOS, see the release notes for the version you want to load on the system.
S60 Quick Start Guide 23
24 Getting Started
Download
Advertisement
Key features
Managed L3 SNMPv1, IGMPv1, IGMPv2, IGMPv3, SSM, PIM-SM, SMIv1, SMIv2
Basic switching RJ-45 Ethernet ports quantity: 44 Console port: RJ-45
10G support 1000BASE-T, 1000BASE-TX, 100BASE-T, 100BASE-TX, 10BASE-T
MAC address table: 32000 entries Switching capacity: 176 Gbit/s
1U Rack mounting Stackable