IFM AP3022 App for parameter setting and set-up of 1D/2D code reader Quick Start Guide
Add to My manuals6 Pages
advertisement
![IFM AP3022 App for parameter setting and set-up of 1D/2D code reader Quick Start Guide | Manualzz IFM AP3022 App for parameter setting and set-up of 1D/2D code reader Quick Start Guide | Manualzz](http://s3.manualzz.com/store/data/025745198_1-34764e27ab2510b46217b8a77628ff25-360x466.png)
i f m S y s t e m S o l u t i o n s
Quick Guide
Article number:
Article name:
Version:
AC14 firmware version:
URL (main page):
URL (additional pages):
AP3022
App AC14 O2I camera
1.0.2
>= V3.1.2 http://<IP-Adresse*>:8080/o2i.htm
-
Languages:
Restrictions in demo mode:
Additional required software:
English
The communication between the
SmartPLC AC14 and the cameras will be interrupted after one hour.
O2I1xx / O2I3xx operating software:
efector dualis Multicode-Reader
Parameter setting software
This program belongs to the shipment of th is App. Additionally it’s available free of charge in the download section on ifm.com
* IP address of the AC14 configuration interface
Short description
Key functions of ifm System Solutions App O2I (AP3022):
Connection setup for up to 5 cameras of type O2I1xx / O2I3xx.
Monitoring of the Ethernet connection to the cameras. The connection status is transferred via the fieldbus to the upper level PLC.
Caution: The connection status of a camera will only be updated for this camera after triggering it.
Gateway function between the ethernet based O2I-Camera-Data and the fieldbus of the AC14: o AC1401/02: Profinet o AC1411/12: Profibus o AC1421/22: EtherNet/IP
The cameras can be triggered via the fieldbus and the Web-Interface.
The reading results of the cameras are transferred to the fieldbus and displayed in the Web-Interface.
i f m S y s t e m S o l u t i o n s
Groundworks for using the ifm System Solutions App
1. Setup the camera within the Software
‘efector dualis Multicode Reader Parameter setting software’ which you can find on the USB stick:
Set the global device settings of the process interface of the O2I-Multicode-
Readers like shown in the picture below:
Set the network parameters of the O2I-Multicode-Readers:
i f m S y s t e m S o l u t i o n s
Create a new configuration and configure all required image quality parameters for your application.
Set the ‘Trigger type’ in the Tab element ‘Trigger configuration’ to ‘TCP/IP’.
Define in the tab element
‘Code type’ the right one for your application, e.g.
EAN13.
For the Process interface settings the default values must be used:
Save all settings and disconnect the existing device connection.
i f m S y s t e m S o l u t i o n s
The user interface
URL of the O2I configuration page: http://<IP-Adresse*>:8080/o2i.htm
On this screen the cameras IP addresses, the port numbers and the code length can be entered. As soon as the option field ‘Activate connection to camera’ is activated, the AC14 tries to establish a connection to the camera. The connection status is shown for each camera.
Caution: The connection status of a camera will only be updated for this camera after triggering it.
Connection settings Code length [characters] Manual trigger
Output field of the detected code.
If no code was detected ‘fail’ is shown here.
If a request is pending ‘busy’ is shown here.
i f m S y s t e m S o l u t i o n s
In word 0 of the fieldbus slot ‘Outputs to AC14nn-PLC’ the O2I cameras can be triggered:
Bit 0: not used
Bit 1: Kamera 1
Bit 2: Kamera 2
Bit 3: Kamera 3
Bit 4: Kamera 4
Bit 5: Kamera 5
The trigger signals of each camera are monitored by the SmartPLC AC14 for a rising edge. Only this edge triggers the camera.
In word 0 of the fieldbus slot
‘Inputs from AC14nn-PLC’ the camera connection status is transmitted:
Bit 0: not used
Bit 1: camera 1
Bit 2: camera 2
Bit 3: camera 3
Bit 4: camera 4
Bit 5: camera 5
True = connection to camera is ok
False = no connection to camera
Caution: The connection status of a camera will only be updated for this camera after triggering it.
i f m S y s t e m S o l u t i o n s
In the words 1 … n of the fieldbus slots ‘Inputs from AC14nn-PLC’ all camera data are transmitted as dada type String. If an odd number is transmitted by a camera the last character is filled with the value 0. That’s because the next camera data should start on n even word number.
Received code data from camera 1.
In this example an EAN13
Code was detected, i.e. 13 charachters ASCII.
0077890256008
Filling byte to make sure that the data of the next camera starts with the next even word address.