KW H2L531.TE
Oslon Black Flat is able to meet a wide range of requirements in terms of output and adaptability to ambient conditions. It offers a uniform light pattern, thermal stability and great brightness.
Die Oslon Black Flat erfüllt viele verschiedene
Anforderungen in Bezug auf die Leistung und die
Anpassungsfähigkeit an die
Umgebungsbedingungen. Sie bietet ein homogenes
Lichtbild, Temperaturstabilität und hohe Helligkeit.
•
•
•
•
•
•
•
Features:
Package: SMD epoxy package
Technology: ThinGaN (UX:3)
Viewing angle at 50 % I
V
: 120° (Lambertian
Emitter)
Color: Cx = 0.32, Cy = 0.33 acc. to CIE 1931
(ultra white)
ESD - withstand voltage: 8 kV acc. to
ANSI/ESDA/JEDEC JS-001 (HBM, Class 3B)
Corrosion Robustness: Improved corrosion robustness
Qualifications: The product qualification test plan is based on the guidelines of AEC-Q101-REV-C,
Stress Test Qualification for Automotive Grade
Discrete Semiconductors.
•
•
•
•
•
•
•
Besondere Merkmale:
Gehäusetyp: SMD Epoxid Gehäuse
Technologie: ThinGaN (UX:3)
Abstrahlwinkel bei 50 % I
V
: 120° (Lambertscher
Strahler)
Farbe: Cx = 0.32, Cy = 0.33 nach CIE 1931 (ultra weiß)
ESD - Festigkeit: 8 kV nach ANSI/ESDA/JEDEC
JS-001 (HBM, Klasse 3B)
Korrosionsstabilität: Verbesserte
Korrosionsstabilität
Qualifikationen: Die Produktqualifikation wurde entsprechend der Richtlinie AEC-Q101-REV-C,
„Stress Test Qualification for Automotive Grade
Discrete Semiconductors“, getestet.
•
•
•
•
•
•
Applications
Automotive Headlamp
Bending light
Lowbeam
Highbeam
Day time running light
Fog lamp
•
•
•
•
•
•
Anwendungen
Frontscheinwerfer im Automobil
Abbiegelicht
Abblendlicht
Fernlicht
Tagfahrlicht
Nebelscheinwerfer
2015-06-17 1
Version 1.3
KW H2L531.TE
Ordering Information
Bestellinformation
Type:
Typ:
KW
H2L531.TE-6P5Q-ebvF46fcbB46-
PAMA
Luminous Flux
I
F
= 1000 mA
Φ
V
[lm]
500 ... 800
Ordering Code
Bestellnummer
Q65111A8110
Note:
Anm.:
be shipped on each packing unit (there will be no mixing of two groups on each packing unit). E. g. KW
H2L531.TE-6P5Q-ebvF46fcbB46-PAMA means that only one group 5Q, 6P, 7P, 8P will be shippable for any packing unit.
In a similar manner for colors where color chromaticity coordinate groups are measured and binned, single groups will be shipped on any one packing unit. KW H2L531.TE-6P5Q-ebvF46fcbB46-PAMA means that the device will be shipped within the specified limits.
In a similar manner for colors where forward voltage groups are measured and binned, single forward voltage groups will be shipped on any packing unit. E. g. KW H2L531.TE-6P5Q-ebvF46fcbB46-PAMA means that only one forward voltage group 1A,BA,MA,PA will be shippable.
Die oben genannten Typbezeichnungen umfassen die bestellbaren Selektionen. Diese bestehen aus wenigen Helligkeitsgruppen
(siehe Seite
Es wird nur eine einzige Helligkeitsgruppe pro Verpackungseinheit geliefert. Z. B. KW
H2L531.TE-6P5Q-ebvF46fcbB46-PAMA bedeutet, dass in einer Verpackungseinheit nur eine der Helligkeitsgruppen 5Q, 6P, 7P, 8P enhalten ist.
Gleiches gilt für die Farben, bei denen Farbortgruppen gemessen und gruppiert werden. Pro Verpackungseinheit wird nur eine
Farbortgruppe geliefert. Z.B. KW H2L531.TE-6P5Q-ebvF46fcbB46-PAMA bedeutet, dass in einer Verpackungseinheit nur eine der
Farbortgruppen enthalten ist. KW H2L531.TE-6P5Q-ebvF46fcbB46-PAMA bedeutet, dass das Bauteil innerhalb der spezifizierten
Grenzen geliefert wird.
Gleiches gilt für die LEDs, bei denen die Durchlassspannungsgruppen gemessen und gruppiert werden. Pro Verpackungseinheit wird nur eine Durchlassspannungsgruppe geliefert. Z. B. KW H2L531.TE-6P5Q-ebvF46fcbB46-PAMA bedeutet, dass nach
Durchlassspannungsgruppen gruppiert wird. In einer Verpackungseinheit ist nur eine der Durchlassspannungsgruppen
1A,BA,MA,PA enthalten (siehe Seite 5).
2015-06-17 2
Version 1.3
KW H2L531.TE
Maximum Ratings
Grenzwerte
Parameter
Bezeichnung
Operating temperature range
Betriebstemperatur
Storage temperature range
Lagertemperatur
Junction temperature for short time applications *
Sperrschichttemperatur für Kurzzeitanwendung *
Junction temperature
Sperrschichttemperatur
Forward current
Durchlassstrom
(T
S
= 25 °C)
Forward current pulsed
Durchlassstrom gepulst
(t ≤ 1 ms, D = 0.1, T
S
= 25 °C)
Reverse voltage
Sperrspannung
(T
S
= 25 °C)
ESD withstand voltage
ESD Festigkeit
(acc. to ANSI/ESDA/JEDEC JS-001 - HBM, Class
3B)
Symbol
Symbol
T op
T stg
T j
T j
I
F
I
F pulse
V
R
V
ESD
Note:
Anm:
*The median lifetime (L70/B50) for Tj = 175°C is 100h.
*Die mittlere Lebensdauer (L70/B50) bei Tj = 175°C beträgt 100h.
Values
Werte
-40 ... 125
-40 ... 125
175
150
50 ... 1500
2000 mA not designed for reverse operation
V
8 kV
Unit
Einheit
°C
°C
°C
°C mA
2015-06-17 3
Version 1.3
Characteristics (T
S
= 25 °C; I
Kennwerte
F
= 1000 mA)
Parameter
Bezeichnung
Chromaticity coordinates acc. to CIE 1931
Viewing angle at 50 % I
V
Abstrahlwinkel bei 50 % I
V
Forward voltage
Durchlassspannung
(typ.)
(typ.)
(typ.)
(min.)
(typ.)
(max.)
Reverse current
Sperrstrom
Radiating surface
Abstrahlende Fläche
Real thermal resistance junction / solder point
Realer Wärmewiderstand Sperrschicht / Lötpad
(typ.)
(typ.)
(max.)
"Electrical" thermal resistance junction / solder point
(typ.)
(max.)
"Elektrischer" Wärmewiderstand Sperrschicht /
(with efficiency η e
= 30 %)
Note: Individual forward voltage groups see next page
Anm.: Durchlassspannungsgruppen siehe nächste Seite
Symbol
Symbol
Cx
Cy
2ϕ
Values
Werte
0.322
0.334
120
V
F
V
F
V
F
I
R
A color
R th JS real
R th JS real
5.45
6.15
7.45
not designed for reverse operation
2.1
V
V
V mm²
1.6
1.9
K/W
K/W
Unit
-
-
Einheit
°
R th JS el
R th JS el
KW H2L531.TE
1.1
1.3
K/W
K/W
2015-06-17 4
Version 1.3
KW H2L531.TE
Brightness Groups
Helligkeitsgruppen
Group
Gruppe
6P
7P
8P
5Q
Luminous Flux
Luminous Flux
Luminous Intensity
(min.) Φ
V
[lm]
500
560
630
710
Forward Voltage Groups
Group
Gruppe
PA
1A
(min.) V
F
5.45
5.95
[V] (max.) V
F
5.95
6.45
[V]
BA
MA
6.45
6.95
6.95
7.45
Lichtstrom
(max.) Φ
V
[lm]
560
630
710
800
(typ.) I
V
[cd]
174.9
196.4
221.1
249.2
2015-06-17 5
Version 1.3
KW H2L531.TE
Chromaticity Coordinate Groups
0,90
Cy
0,80
515
510
0,70
505
0,60
500
0,50
520
525
530
540
550
560
570
580
590
0,40
495
0,30
490
600
610
620
630
650
700
0,20
485
0,10
0,00
0,00
480
475
470
465
460
450
400
0,10 0,20 0,30 0,40 0,50 0,60 0,70
Cx
0,37
Cy
0,36
0,35
0,34
0,33
0,32
0,31
0,30
0,29 fcbB46 ebzB46 ebxD46 ebvF46
0,30 0,31 0,32 0,33
Cx
0,34
Farbortgruppen
Cx Group
Gruppe
ebzB46 0.3190
0.3203
Cy
0.3430
0.3274
fcbB46
0.3298
0.3299
0.3241
0.3248
0.3350
0.3355
0.3526
0.3361
0.3534
0.3370
0.3460
0.3633
Group
Gruppe
ebxD46 ebvF46
Cx
0.3145
0.3163
0.3246
0.3253
0.3104
0.3127
0.3199
0.3212
Cy
0.3330
0.3181
0.3424
0.3266
0.3234
0.3093
0.3325
0.3175
2015-06-17 6
Version 1.3
KW H2L531.TE
Group Name on Label
Gruppenbezeichnung auf Etikett
Example: 5Q-ebvF46-PA
Beispiel: 5Q-ebvF46-PA
Brightness
Helligkeit
5Q
Chromaticity Coordinate
Farbort
ebvF46
Forward Voltage
Durchlassspannung
PA
Note:
Anm.:
No packing unit / tape ever contains more than one group for each selection.
In einer Verpackungseinheit / Gurt ist immer nur eine Gruppe für jede Selektion enthalten.
2015-06-17 7
Version 1.3
KW H2L531.TE
Relative Spectral Emission - V(λ) = Standard eye response curve
Relative spektrale Emission - V(λ) = spektrale Augenempfindlichkeit
Φ rel
= f (λ); T
S
= 25 °C; I
F
= 1000 mA
KW H2L531.TE
Φ rel
1,0
: V
λ
: white
0,8
0,6
0,4
0,2
0,0
350 400 450 500 550 600 650 700 750 800
λ
[nm]
I rel
= f (ϕ); T
S
= 25 °C
-20°
-10°
KW H2L531.TE
ϕ
[°]
0° 10° 20° 30° 40° 50° 60° 70° 80° 90°
1,0
I rel
-30°
-40°
0,8
-50°
0,6
-60°
0,4
-70°
0,2
-80°
-90° 0,0
-100°
2015-06-17 8
Version 1.3
KW H2L531.TE
Durchlassstrom
I
F
= f (V
F
); T
S
= 25 °C
KW H2L531.TE
I
F
[mA]
1500
1400
: white
1200
1000
800
600
400
200
50
5,3 5,4 5,6 5,8 6,0 6,2 6,4 6,5
V
F
[V]
Chromaticity Coordinate Shift
Cx, Cy = f(I
F
); T
S
= 25 °C
KW H2L531.TE
Cx
Cy
: Cx
: Cy
0,35
Relative Luminous Flux
Relativer Lichtstrom
Φ
V
/Φ
V
(1000 mA) = f(I
F
); T
S
= 25 °C
Φ
V
KW H2L531.TE
Φ
V
(1000mA)
1,4 : white
1,2
1,0
0,8
0,6
0,4
0,2
0,0
50
20
0
40
0
60
0
80
0
10
00
12
00
14
00
15
00
I
F
[mA]
0,34
0,33
0,32
50
20
0
40
0
60
0
80
0
10
00
12
00
15
00
I
F
[mA]
2015-06-17 9
Version 1.3
KW H2L531.TE
Relative Forward Voltage
Relative Vorwärtsspannung
ΔV
F
= V
F
- V
F
(25 °C) = f(T j
); I
F
= 1000 mA
KW H2L531.TE
∆
V
F
[V]
0,4
0,2
0,0
-0,2
: white
-0,4
-4
0
-2
0 0
20 40 60 80
10
0
12
0
14
0
T
j
[°C]
Chromaticity Coordinate Shift
Cx, Cy = f(Tj); I
F
= 1000 mA
KW H2L531.TE
Cx
Cy
0,340
0,335
: Cx
: Cy
0,330
0,325
0,320
0,315
0,310
-4
0
-2
0 0
20 40 60 80
10
0
12
0
14
0
T
j
[°C]
Relative Luminous Flux
Relativer Lichtstrom
Φ
V
/Φ
V
(25 °C) = f(T j
); I
F
= 1000 mA
Φ v
Φ v
(25°C)
1,2
: white
KW H2L531.TE
1,0
0,8
0,6
0,4
0,2
0,0
-4
0
-2
0 0
20 40 60 80
10
0
12
0
14
0
T
j
[°C]
2015-06-17 10
Version 1.3
KW H2L531.TE
Max. Permissible Forward Current
Max. zulässiger Durchlassstrom
I
F
= f (T); 0.7 * Φ
V min.
of bin 6P; R th real max.
K W H2L531.T E
1600
I
F
[mA]
1500
1400
1300
1200
1100
1000
900
800
700
600
500
400
300
200
100
: T s
Do not us e below 50 mA
0
0 20 40 60 80 100 120 140
T
s
[°C ]
Permissible Pulse Handling Capability
Zulässige Impulsbelastbarkeit I
F
D: Duty cycle
= f(t p
)
I
F
[A]
2,2
T
A
= 0°C ... 125°C
KW H2L531.TE
2,0
: D = 1.0
: D = 0.5
: D = 0.2
: D = 0.1
: D = 0.05
: D = 0.02
: D = 0.01
: D = 0.005
1,8
Permissible Pulse Handling Capability
Zulässige Impulsbelastbarkeit I
D: Duty cycle
F
= f(t p
)
I
F
[A]
2,2
T
A
= 125°C
KW H2L531.TE
2,0
: D = 1.0
: D = 0.5
: D = 0.2
: D = 0.1
: D = 0.05
: D = 0.02
: D = 0.01
: D = 0.005
1,8
1,6
1,4
10
-6
10
-5
10
-4
10
-3
0,01 0,1 1 10
Pulse time [s]
1,6
1,4
10
-6
10
-5
10
-4
10
-3
0,01 0,1 1 10
Pulse time [s]
2015-06-17 11
Version 1.3
KW H2L531.TE
Approximate Weight:
Gewicht:
Note
Anm.
ESD information:
ESD Information:
Corrosion robustness:
2015-06-17 12
18 mg
18 mg
Percentage of red: >5% acc. to ECE regulation
Percentage of UV: <10-5 W/lm acc. to ECE regulation
Rotanteil: >5% gem. ECE-Richtlinie UV-Anteil:
<10-5 W/lm gem. ECE-Richtlinie
LED is protected by ESD device which is connected in parallel to LED-Chip.
Die LED enthält ein ESD-Bauteil, das parallel zum
Chip geschaltet ist.
Test conditions: 40 °C / 90 % rh / 15 ppm H
2
336 h
= Stricter than IEC 60068-2-43 (H
2
S /
S) [25°C / 75 % rh / 10 ppm H
2
S / 21 days]
= Regarding relevant gas (H
2
, 200 ppb NO
2,
10 ppb Cl
2
S) stricter than EN
60068-2-60 (method 4) [25 °C / 75 % rh / 200 ppb
SO
2
/ 21 days]
Version 1.3
Korrosionsfestigkeit:
Electrical Internal Circuit
Internes Elektrisches Schaltbild
KW H2L531.TE
Test Kondition: 40°C / 90 % rh / 15 ppm H
2 h
= Besser als IEC 60068-2-43 (H
2
S / 336
S) [25°C / 75 % rh / 10 ppm H
60068-2-60 (method 4) [25°C / 75 % rh / 200ppb
SO
2
2
S / 21 Tage]
= Bezogen auf das Gas (H
, 200ppb NO
2,
10ppb Cl
2
S) besser als EN
2
/ 21 Tage]
2015-06-17 13
Version 1.3
Recommended Solder Pad
Empfohlenes Lötpaddesign
Reflow soldering
Reflow-Löten
KW H2L531.TE
Note:
Anm.:
For superior solder joint connectivity results we recommend soldering under standard nitrogen atmosphere.
Package not suitable for ultra sonic cleaning.
Um eine verbesserte Lötstellenkontaktierung zu erreichen, empfehlen wir, unter Standard-
Stickstoffatmosphäre zu löten.
Das Gehäuse ist für Ultraschallreinigung nicht geeignet.
2015-06-17 14
Version 1.3
KW H2L531.TE
Reflow Soldering Profile
Reflow-Lötprofil
Product complies to MSL Level 2 acc. to JEDEC J-STD-020D.01
300
˚C
T
250
240 ˚C
217 ˚C
200
t
P
t
L
150
t
S
100
50
0
0
25 ˚C
50 100 150 200 250
T
p
245 ˚C
t
s
OHA04525
300
Profile Feature
Profil-Charakteristik
Symbol
Symbol
Pb-Free (SnAgCu) Assembly
Minimum Recommendation
2
Maximum
3 Ramp-up rate to preheat*
)
25 °C to 150 °C
Time t
S
T
Smin
to T
Smax
Ramp-up rate to peak*
)
T
Smax
to T
P
Liquidus temperature
Time above liquidus temperature t
S
60 100
2
T
L t
L
217
80
Peak temperature
Time within 5 °C of the specified peak temperature T
P
- 5 K t
T
P
P
10
245
20
Ramp-down rate*
T
P
to 100 °C
Time
25 °C to T
P
3
All temperatures refer to the center of the package, measured on the top of the component
* slope calculation DT/Dt: Dt max. 5 s; fulfillment for the whole T-range
120
3
100
260
30
6
480 s
K/s s
°C s
°C s
K/s
OHA04612
Unit
Einheit
K/s
2015-06-17 15
Version 1.3
Taping
KW H2L531.TE
2015-06-17 16
Version 1.3
Tape and Reel
Gurtverpackung
12 mm tape with 2000 pcs. on ∅ 180 mm reel
W
1
D
0
P
2
P
0
KW H2L531.TE
P
1
Direction of unreeling
W
2
Label
Direction of unreeling
Leader:
Trailer: min. 400 mm * min. 160 mm *
*) Dimensions acc. to IEC 60286-3; EIA 481-D
OHAY0324
Tape dimensions [mm]
Gurtmaße [mm]
Tape dim ensi ons in m m
W
P
0
12 + 0.3 / - 0.1 4 ± 0.1
P
1
4 ± 0.1
or
8 ± 0.1
Reel dimensions [mm]
Rollenmaße [mm]
Reel dim ensi ons in m m
A W
180 12
N min
60
P
2
2 ± 0.05
D
0
1.5 ± 0.1
E
1.75 ± 0.1
F
5.5 ± 0.05
W
1
12.4 + 2
W
2max
18.4
2015-06-17 17
Version 1.3
Dry Packing Process and Materials
Trockenverpackung und Materialien
Moisture-sensitive label or print
Barcode label
LEVEL
<
30 ˚C/60% RH.
MOISTURE SENSITIVE
at factory conditions of
OPTO SEMICONDUCTORS
Floor time 72 Hours
Floor time 24 Hours
Floor time 6 Hours
Floor time see below
If blank, see bar code label
_ 10% RH.
Moisture Level 4
Moisture Level 5
Moisture Level 6
(if blank, seal date is identical with date code).
1. Shelf life in sealed bag: 24 months at < 40 ˚C and < 90% relative humidity (RH).
body temp.
a) Mounted within b) Stored at b) 2a or 2b is not met.
4. If baking is required,
Floor time > 1 Year a) Humidity Indicator Card is > 10% when read at 23 ˚C ± 5 ˚C, or
Floor time 168 Hours reference IPC/JEDEC J-STD-033 for bake procedure.
Bag seal date
Date and time opened:
Moisture Level 1
Moisture Level 2
Moisture Level 2a
OSRAM
Humidity indicator
Barcode label examine units, if necessary examine units, if necessary
MIL-I-8835
Humidity Indicator
If wet, change desiccant
If wet, bake units check dot
Comparator
If wet, bake units
Avoid metal contact.
bag opening.
Do not eat.
Discard if circles overrun.
Please check the HIC immidiately after parts still adequately dry.
15%
WET
10%
OSRAM
Desiccant
Barcode-Product-Label (BPL)
Barcode-Produkt-Etikett (BPL)
(1T) LOT NO:
(X) PROD NO:
EXAM
1234567890
123456789
(Q)QTY:
9999
LX XXXX
RoHS Compliant
(G) GROUP:
ML
X
BIN1: XX-XX-X-XXX-X
Temp ST
XXX °C X
PLE
OHA04563
OHA00539
Transportation Packing and Materials
Kartonverpackung und Materialien
KW H2L531.TE
2015-06-17
LEVEL
CAUTION
This bag contains
˚C).
at factory conditions of
OPTO SEMICONDUCTORS
<
30 ˚C/60% RH.
Floor time 72 Hours
Floor time 24 Hours
Floor time 6 Hours
Floor time see below
If blank, see bar code label
<
10% RH.
Moisture Level 4
Moisture Level 5
Moisture Level 5a
(if blank, seal date is identical with date code).
body temp.
a) Mounted within b) Stored at Floor time > 1 Year
Floor time 1 Year
3. Devices require baking, before mounting, if: reference IPC/JEDEC J-STD-033 for bake procedure.
4. If baking is required,
Floor time 168 Hours
Bag seal date
Date and time opened:
Moisture Level 1
Moisture Level 2
Moisture Level 2a
Moisture Level 3
LSY T676
Bin1: P-1-20
Multi TOPLED
Bin3:
ML 2
Temp ST
2a
220 C R
240 C R
260 C RT
3
Additional TEXT
R077
PACKVAR:
DEMY
R18
P-1+Q-1
(G) GROUP:
210021998
(9D) D/C:
0144
(Q)QTY:
2000
(6P) BATCH NO:
(1T) LOT NO:
123GH1234
1
0 0
1
(X) PROD NO:
Barcode label
Packing
Sealing label
210021998
(9D) D/C:
(6P) BATCH NO:
(1T) LOT NO:
123GH1234
1 1
0 1
LSY T676
Bin1: P-1-20
Bin2: Q-1-20
Bin3:
ML
Multi TOPLED
2
2a
3
240 C R
260 C RT
Additional TEXT
R077
PACKVAR:
DEMY
R18
P-1+Q-1
(G) GROUP:
0144
(Q)QTY:
2000
(X) PROD NO:
Barcode label
OSRAM
OHA02044
18
Version 1.3
KW H2L531.TE
Note:
Moisture-sensitive product is packed in a dry bag containing desiccant and a humidity card.
Regarding dry pack you will find further information in the internet and in the Short Form Catalog in chapter “Tape and Reel” under the topic “Dry
Pack”. Here you will also find the normative references like JEDEC.
Anm.:
Feuchteempfindliche Produkte sind verpackt in einem Trockenbeutel zusammen mit einem Trockenmittel und einer Feuchteindikatorkarte.
Bezüglich Trockenverpackung finden Sie weitere Hinweise im Internet und in unserem Short Form Catalog im Kapitel “Gurtung und Verpackung” unter dem Punkt “Trockenverpackung”. Hier sind Normenbezüge, unter anderem ein Auszug der JEDEC-Norm, enthalten.
Dimensions of transportation box in mm
Width Length
Breite
195 ± 5
Länge
195 ± 5
Height
Höhe
30 ± 5
Notes
The evaluation of eye safety occurs according to the standard IEC 62471:2008 ("photobiological safety of lamps and lamp systems"). Within the risk grouping system of this CIE standard, the LED specified in this data sheet fall into the class Moderate risk (exposure time 0.25 s). Under real circumstances (for exposure time, eye pupils, observation distance), it is assumed that no endangerment to the eye exists from these devices. As a matter of principle, however, it should be mentioned that intense light sources have a high secondary exposure potential due to their blinding effect. As is also true when viewing other bright light sources (e.g. headlights), temporary reduction in visual acuity and afterimages can occur, leading to irritation, annoyance, visual impairment, and even accidents, depending on the situation.
Subcomponents of this LED contain, among other substances, goldplated and Ag-filled materials. In spite of the improved corrosion stability of this LED, it can be affected by environments that contain very high concentrations of aggressive substances.
Therefore, we recommend avoiding aggressive atmospheres during storage, production and use.
Hinweise
Die Bewertung der Augensicherheit erfolgt nach dem Standard IEC 62471:2008 ("photobiological safety of lamps and lamp systems"). Im
Risikogruppensystem dieser CIE- Norm erfüllen die in diesem Datenblatt angegebenen LEDs folgende
Gruppenanforderung - Moderate risk
(Expositionsdauer 0,25 s). Unter realen Umständen
(für Expositionsdauer, Augenpupille,
Betrachtungsabstand) geht damit von diesen
Bauelementen keinerlei Augengefährdung aus.
Grundsätzlich sollte jedoch erwähnt werden, dass intensive Lichtquellen durch ihre Blendwirkung ein hohes sekundäres Gefahrenpotenzial besitzen.
Nach einem Blick in eine helle Lichtquelle (z.B.
Autoscheinwerfer), kann ein temporär eingeschränktes Sehvermögen oder auch
Nachbilder zu Irritationen, Belästigungen,
Beeinträchtigungen oder sogar Unfällen führen.
Einzelkomponenten dieser LED enthalten u.a. goldbeschichtete und Ag-gefüllte Materialien. Trotz der verbesserten Korrosionsstabilität dieser LED können Einzelkomponenten durch sehr hohe
Konzentration aggressiver Substanzen angegriffen werden. Aus diesem Grund wird empfohlen, aggressive Umgebungen während der Lagerung,
Produktion und im Betrieb zu vermeiden.
2015-06-17 19
Version 1.3
KW H2L531.TE
Disclaimer
Language english will prevail in case of any discrepancies or deviations between the two language wordings.
Attention please!
The information describes the type of component and shall not be considered as assured characteristics.
Terms of delivery and rights to change design reserved.
Due to technical requirements components may contain dangerous substances.
For information on the types in question please contact our Sales Organization.
If printed or downloaded, please find the latest version in the Internet.
Packing
Please use the recycling operators known to you. We can also help you – get in touch with your nearest sales office.
By agreement we will take packing material back, if it is sorted. You must bear the costs of transport. For packing material that is returned to us unsorted or which we are not obliged to accept, we shall have to invoice you for any costs incurred.
Components used in life-support devices or systems must be expressly authorized for such purpose!
Critical components* may only be used in life-support devices** or systems with the express written approval of OSRAM OS.
*) A critical component is a component used in a life-support device or system whose failure can reasonably be expected to cause the failure of that life-support device or system, or to affect its safety or the effectiveness of that device or system.
**) Life support devices or systems are intended (a) to be implanted in the human body, or (b) to support and/or maintain and sustain human life. If they fail, it is reasonable to assume that the health and the life of the user may be endangered.
Disclaimer
Bei abweichenden Angaben im zweisprachigen
Wortlaut haben die Angaben in englischer Sprache
Vorrang.
Bitte beachten!
Lieferbedingungen und Änderungen im Design vorbehalten. Aufgrund technischer Anforderungen können die Bauteile Gefahrstoffe enthalten. Für weitere
Informationen zu gewünschten Bauteilen, wenden Sie sich bitte an unseren Vertrieb. Falls Sie dieses
Datenblatt ausgedruckt oder heruntergeladen haben, finden Sie die aktuellste Version im Internet.
Verpackung
Benutzen Sie bitte die Ihnen bekannten
Recyclingwege. Wenn diese nicht bekannt sein sollten, wenden Sie sich bitte an das nächstgelegene
Vertriebsbüro. Wir nehmen das Verpackungsmaterial zurück, falls dies vereinbart wurde und das Material sortiert ist. Sie tragen die Transportkosten. Für
Verpackungsmaterial, das unsortiert an uns zurückgeschickt wird oder das wir nicht annehmen müssen, stellen wir Ihnen die anfallenden Kosten in
Rechnung.
Bauteile, die in lebenserhaltenden Apparaten und
Systemen eingesetzt werden, müssen für diese
Zwecke ausdrücklich zugelassen sein!
Kritische Bauteile* dürfen in lebenserhaltenden
Apparaten und Systemen** nur dann eingesetzt werden, wenn ein schriftliches Einverständnis von
OSRAM OS vorliegt.
*) Ein kritisches Bauteil ist ein Bauteil, das in lebenserhaltenden Apparaten oder Systemen eingesetzt wird und dessen Defekt voraussichtlich zu einer Fehlfunktion dieses lebenserhaltenden
Apparates oder Systems führen wird oder die
Sicherheit oder Effektivität dieses Apparates oder
Systems beeinträchtigt.
**) Lebenserhaltende Apparate oder Systeme sind für
(a) die Implantierung in den menschlichen Körper oder
(b) für die Lebenserhaltung bestimmt. Falls Sie versagen, kann davon ausgegangen werden, dass die
Gesundheit und das Leben des Patienten in Gefahr ist.
2015-06-17 20
Version 1.3
KW H2L531.TE
Glossary
1)
Brightness: Brightness values are measured during a current pulse of typically 25 ms, with an internal reproducibility of ± 8 % and an expanded uncertainty of ± 11 % (acc. to GUM with a coverage factor of k = 3).
2)
Chromaticity coordinate groups: Chromaticity coordinates are measured during a current pulse of typically 25 ms, with an internal reproducibility of
± 0.005 and an expanded uncertainty of ± 0.01 (acc. to GUM with a coverage factor of k = 3).
3)
Forward Voltage: The forward voltage is measured during a current pulse of typically 8 ms, with an internal reproducibility of ± 0.05 V and an expanded uncertainty of ± 0.1 V (acc. to GUM with a coverage factor of k = 3).
4)
Thermal Resistance: Rth max is based on statistic values (6σ).
5)
Typical Values: Due to the special conditions of the manufacturing processes of LED, the typical data or calculated correlations of technical parameters can only reflect statistical figures. These do not necessarily correspond to the actual parameters of each single product, which could differ from the typical data and calculated correlations or the typical characteristic line. If requested, e.g. because of technical improvements, these typ. data will be changed without any further notice.
6)
Characteristic curve: In the range where the line of the graph is broken, you must expect higher differences between single LEDs within one packing unit.
7)
Tolerance of Measure: Unless otherwise noted in drawing, tolerances are specified with ±0.1 and dimensions are specified in mm.
Glossar
1)
Helligkeit: Helligkeitswerte werden während eines
Strompulses einer typischen Dauer von 25 ms, mit einer internen Reproduzierbarkeit von ± 8 % und einer erweiterten Messunsicherheit von ± 11 % gemessen (gemäß GUM mit Erweiterungsfaktor k = 3).
2)
Farbortgruppen: Farbkoordinaten werden während eines Strompulses einer typischen Dauer von 25 ms, mit einer internen Reproduzierbarkeit von ± 0,005 und einer erweiterten Messunsicherheit von ± 0,01 gemessen (gemäß GUM mit Erweiterungsfaktor k = 3).
3)
Durchlassspannung: Vorwärtsspannungen werden während eines Strompulses einer typischen
Dauer von 8 ms, mit einer internen
Reproduzierbarkeit von ± 0,05 V und einer erweiterten Messunsicherheit von ± 0,1 V gemessen
(gemäß GUM mit Erweiterungsfaktor k = 3).
4)
Wärmewiderstand: Rth max basiert statistischen Werten (6σ).
auf
5)
Typische Werte: Wegen der besonderen
Prozessbedingungen bei der Herstellung von LED können typische oder abgeleitete technische
Parameter nur aufgrund statistischer Werte wiedergegeben werden. Diese stimmen nicht notwendigerweise mit den Werten jedes einzelnen
Produktes überein, dessen Werte sich von typischen und abgeleiteten Werten oder typischen Kennlinien unterscheiden können. Falls erforderlich, z.B. aufgrund technischer Verbesserungen, werden diese typischen Werte ohne weitere Ankündigung geändert.
6)
Kennlinien: Im gestrichelten Bereich der Kennlinien muss mit erhöhten Abweichungen zwischen
Leuchtdioden innerhalb einer Verpackungseinheit gerechnet werden.
7)
Maßtoleranz: Wenn in der Zeichnung nicht anders angegeben, gilt eine Toleranz von ±0,1. Maße werden in mm angegeben.
2015-06-17 21
Version 1.3
KW H2L531.TE
Published by OSRAM Opto Semiconductors GmbH
Leibnizstraße 4, D-93055 Regensburg www.osram-os.com © All Rights Reserved.
2015-06-17 22
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
advertisement
Table of contents
- 1 Features:
- 1 Besondere Merkmale:
- 1 Applications
- 1 Anwendungen
- 2 Ordering Information
- 2 Bestellinformation
- 3 Maximum Ratings
- 3 Grenzwerte
- 4 Characteristics
- 4 Kennwerte
- 5 Brightness Groups
- 5 Helligkeitsgruppen
- 5 Forward Voltage Groups
- 5 Durchlassspannungsgruppen
- 6 Chromaticity Coordinate Groups
- 6 Farbortgruppen
- 6 Color Chromaticity Groups
- 6 Farbortgruppen
- 7 Group Name on Label
- 7 Gruppenbezeichnung auf Etikett
- 8 Relative Spectral Emission - V(λ) = Standard eye response curve
- 8 Relative spektrale Emission - V(λ) = spektrale Augenempfindlichkeit
- 8 Radiation Characteristics
- 8 Abstrahlcharakteristik
- 9 Forward Current
- 9 Durchlassstrom
- 9 Relative Luminous Flux
- 9 Relativer Lichtstrom
- 9 Chromaticity Coordinate Shift
- 9 Farbortverschiebung
- 10 Relative Forward Voltage
- 10 Relative Vorwärtsspannung
- 10 Relative Luminous Flux
- 10 Relativer Lichtstrom
- 10 Chromaticity Coordinate Shift
- 10 Farbortverschiebung
- 11 Max. Permissible Forward Current
- 11 Max. zulässiger Durchlassstrom
- 11 Permissible Pulse Handling Capability
- 11 Zulässige Impulsbelastbarkeit IF = f(tp)
- 11 Permissible Pulse Handling Capability
- 11 Zulässige Impulsbelastbarkeit IF = f(tp)
- 12 Package Outline
- 12 Maßzeichnung
- 13 Electrical Internal Circuit
- 13 Internes Elektrisches Schaltbild
- 14 Recommended Solder Pad
- 14 Empfohlenes Lötpaddesign
- 15 Reflow Soldering Profile
- 15 Reflow-Lötprofil
- 16 Taping
- 16 Gurtung
- 17 Tape and Reel
- 17 Gurtverpackung
- 18 Dry Packing Process and Materials
- 18 Trockenverpackung und Materialien
- 18 Barcode-Product-Label (BPL)
- 18 Barcode-Produkt-Etikett (BPL)
- 18 Transportation Packing and Materials
- 18 Kartonverpackung und Materialien
- 19 Notes
- 19 Hinweise
- 20 Disclaimer
- 20 Disclaimer
- 21 Glossary
- 21 Glossar