LC3-UC06E Ceiling Loudspeaker
Communications Systems | LC3-UC06E Ceiling Loudspeaker
LC3-UC06E Ceiling Loudspeaker
www.boschsecurity.com
The LC3‑UC06E is a general purpose, cost-effective
6 W ceiling loudspeaker, suitable for 100 V connection
with power tapping of: 6, 3, 1.5 and 0.75 Watt.
The optional back‑box LC3‑CBB fully protects the
loudspeaker from dust and dripping water from above,
according IP21C.
The loudspeaker frame, grill and back‑box are
manufactured from self‑extinguishing ABS according to
UL 94V0.
u
Suitable for speech and music reproduction
u
Light weight ABS material
u
Easy to install
u
Unobtrusive design
u
EN 54‑24 certified
Emergency
According to BS 5839‑8
According to EN 54‑24
CE
Declaration of Conformity
Safety
According to EN 60065
UL compliancy
According to UL 94 V 0
Notice
To be compliant with EN 54‑24:
Certifications and approvals
Quality assurance
All Bosch loudspeakers are designed to withstand
operating at their rated power for 100 hours in
accordance with IEC 268-5 Power Handling Capacity
(PHC) standards. Bosch has also developed the
Simulated Acoustical Feedback Exposure (SAFE) test
to demonstrate that they can withstand two times
their rated power for short durations. This ensures
improved reliability under extreme conditions, leading
to higher customer satisfaction, longer operating life,
and lessons the chance of failure or performance
deterioration.
The loudspeaker must be installed with the
back‑box LC3‑CBB.
Region
Certification
Poland
CNBOP
Installation/configuration notes
Installation is easy with integral spring arms that
securely hold the ceiling loudspeaker in its cut‑out.
Ceilings from 5 to 25 mm thick can be accommodated.
A template is also provided for accurately marking the
cut-out in ceiling panels.
2 | LC3-UC06E Ceiling Loudspeaker
LC3-CCB
6W
3W
+
1.5W
0.75W
4
-
Circuit diagram LC3-UC06E
dB SPL
The loudspeaker has built‑in protection to ensure that,
in the event of a fire, damage to the loudspeaker does
not result in failure of the circuit to which it is
connected. In this way, system integrity is maintained;
ensuring loudspeakers in other areas can still be used
to inform people of the situation.
The loudspeaker has a ceramic screw‑terminal
connection block, thermal fuse and heat‑resistant high
temperature wiring.
Four primary taps for 100 V are provided on the
matching transformer to allow selection of nominal
full‑power, half‑power, quarter‑power and
one‑eight‑power.
The optional back‑box (LC3‑CBB) protects the rear of
the loudspeaker from dust, falling objects, makes the
unit vermin proof and prevents sound traveling via the
ceiling cavity to adjacent areas.
The back‑box is assembled with the loudspeaker by
means of a snap‑in construction and has knock‑out
holes for two grommets (11 mm) and for two cable
glands (20.5 mm).
110
10 0
2x 20.5 mm / 0.80 in
90
163 mm / 6.41 in
2x 11 mm / 0.43 in
153.5 mm / 6.04 in
80
110.6 mm / 4.35 in
11 mm / 0.43 in
70
60
10
10 0
10 0 0
10 0 0 0
10 0 0 0 0
Frequency
Frequency-response LC3-UC06E
180 mm / 7.08 in
63 mm / 2.48 in
162 mm / 6.37 in
11 mm / 0.43 in
Mechanical diagram LC3‑UC06E and LC3‑CBB
LC3-UC06E specified active equalization required for
EN 54‑24
LC3-UC06E and LC3-CBB
3 | LC3-UC06E Ceiling Loudspeaker
0
340
10
350
5
20
Octave band sensitivity LC3‑UC06E *
30
330
0
320
310
40
-10
300
70
-20
280
Total octave
SPL
1W/1m
Total octave
SPL
Pmax/1m
125 Hz
91.3
-
-
250 Hz
89.1
-
-
500 Hz
86.2
-
-
1000 Hz
85.5
-
-
2000 Hz
89.4
4000 Hz
93.2
-
-
8000 Hz
92.7
-
-
A-weighted
-
88.0
94.7
Lin-weighted
-
89.0
96.0
60
-15
290
Octave SPL
1W/1m
50
-5
80
-25
90
270
-30
100
260
250
110
120
240
230
130
220
140
210
150
200
190
170
160
180
Octave band opening angles LC3‑UC06E
pink noise octave
125
250
500
LC3‑UC06E horizontal/vertical polar diagram (low
frequency). Normalized at 0-degrees axis
0
340
350
10
5
20
330
30
0
320
310
40
60
-10
-15
290
70
-20
280
125 Hz
180
180
250 Hz
180
180
500 Hz
180
180
1000 Hz
180
180
2000 Hz
180
180
4000 Hz
85
85
8000 Hz
56
56
90
Acoustical performance specified per octave
* (all measurements are done with a pink noise signal;
the values are in dBSPL)
100
Parts included
80
-25
270
-30
260
250
110
240
120
230
130
140
220
210
Quantity
Components
1
LC3‑UC06E Ceiling Loudspeaker
1
Installation Instruction
1
Ceiling cut‑out template
150
200
190
170
160
180
2000
4000
Technical specifications
Electrical
pink noise octave
1000
Vertical
50
-5
300
Horizontal
1000
LC3‑UC06E
8000
LC3‑UC06E horizontal/vertical polar diagram (high
frequency). Normalized at 0-degrees axis
Description
Ceiling loudspeaker
Maximum power
9W
Rated power
6 W (6/3/1.5/0.75 W)
Sound pressure level
at 6 W power / 1 W
(1 kHz, 1 m)
94 dB / 86 dB (SPL)
4 | LC3-UC06E Ceiling Loudspeaker
Ordering information
Opening angle
at 1 kHz / 4kHz (-6 dB)
180° / 85°
Effective frequency
range
(-10 dB)
90 Hz to 20 kHz
Rated voltage
100 V
Order number LC3-UC06E
Rated impedance
1667 Ohm
Accessories
Electrical connection
3‑pole ceramic screw terminal block
Acceptable wire gauge
0.5 – 3 mm2
LC3-UC06E Ceiling Loudspeaker
Ceiling loudspeaker 6 W, circular ABS grille and frame,
ceiling mounted by 2 integral spring arms, EN54-24
certified, white RAL 9010.
Mechanical
LC3‑UC06E
LC3‑CBB
Description
Ceiling
Loudspeaker
Back‑Box
Diameter
180 mm (7.08 in)
148 mm (5.82 in)
Mounting cut‑out
167 mm (6.57 in)
-
Max. ceiling thickness
5 to 25 mm
(0.19 to 0.98 in)
-
Maximum depth
63 mm (2.48 in)
96.3 mm (3.79 in)
Material (frame, front
grille)
ABS
ABS
Weight
538 g (1.19 lb)
110 g (0.24 lb)
Color
White (RAL 9010)
White (RAL 9010)
Environmental
Operating
temperature
-25 ºC to +55 ºC (-13 ºF to +131 ºF)
Storage temperature
-40 ºC to +70 ºC (-40 ºF to +158 ºF)
Relative humidity
<95%
1438
Bosch Security Systems BV
Torenallee 49, 5617BA Eindhoven, The Netherlands
10
1438-CPD-0336
EN 54-24:2008
Loudspeaker for voice alarm systems
for fire detection and fire alarm systems for buildings
Ceiling loudspeaker 6 W and accessories
LC3-UC06E, LC3-CBB
Type A
LC3‑CBB Back Box
Back box for LC3 ceiling speakers, fully protects the
loudspeaker from dust and dripping water, makes the
unit vermin proof and prevents sound traveling via the
ceiling cavity to adjacent areas, white RAL 9010.
Order number LC3-CBB
5 | LC3-UC06E Ceiling Loudspeaker
Represented by:
Americas:
Bosch Security Systems, Inc.
12000 Portland Avenue South
Burnsville MN 55337, USA
Phone: +1-800-392-3497
Fax: +1-800-955-6831
audiosupport@us.bosch.com
www.boschsecurity.com
Europe, Middle East, Africa:
Bosch Security Systems B.V.
P.O. Box 80002
5617 BA Eindhoven, The Netherlands
Phone: + 31 40 2577 284
Fax: +31 40 2577 330
emea.securitysystems@bosch.com
www.boschsecurity.com
© Bosch Security Systems 2013 | Data subject to change without notice
10144701323 | en, V7, 07. Nov 2013
Asia-Pacific:
Robert Bosch (SEA) Pte Ltd, Security
Systems
11 Bishan Street 21
Singapore 573943
Phone: +65 6571 2808
Fax: +65 6571 2699
apr.securitysystems@bosch.com
www.boschsecurity.asia
China:
America Latina:
Bosch (Shanghai) Security Systems Ltd. Robert Bosch Ltda Security Systems Division
201 Building, No. 333 Fuquan Road
Via Anhanguera, Km 98
North IBP
CEP 13065-900
Changning District, Shanghai
Campinas, Sao Paulo, Brazil
200335 China
Phone: +55 19 2103 2860
Phone +86 21 22181111
Fax: +55 19 2103 2862
Fax: +86 21 22182398
latam.boschsecurity@bosch.com
www.boschsecurity.com.cn
www.boschsecurity.com