Avocent PM 3000 Vertical Model Data Sheet
Werbung
Werbung
Avocent Data Sheet
PM 1000/2000/3000
Power Distribution Units (PM PDUs)
Avocent Power Management
The Avocent PM PDUs include single-phase and three-phase models that support strip-level metering, outlet-level metering or outlet-level metering and switching. This advanced family of rack PDUs includes horizontal and vertical models for a variety of rack configurations in branch and remote offices.
The PM PDUs include an LED display and a built-in browser interface for local and remote access to real-time data. The metering features, along with the capability to set custom thresholds, allow companies to optimize their electrical infrastructure, without the risk of downtime due to overloaded circuits.
The PM 1000 PDUs enable companies of all sizes to accurately measure the current, voltage and power for the entire strip and the circuits within. The PM 2000 and PM 3000 PDUs take this a step further to support outlet-level metering and switching capability (PM 3000 PDUs only) to provide data center professionals the tools they need to monitor, measure, reduce and manage the growing power consumption costs of IT equipment.
All of these PDUs include advanced features that consist of a built-in network port for access to the browser interface, daisy chain ports for easy installation and expansion and support for external environmental sensors.
PDU
Product
Family
PM 1000
Metering
Capability
Strip level
Switching
Capability
None
Environmental
Sensor
Support
Yes
Daisy
Chain
Capability
Yes
Main
Interface
Options
Management
Options
Serial* or
IP
Stand alone or integrated with DSView 3 management software
PM 2000 Outlet level None Yes Yes
Serial* or
IP
Stand alone or integrated with DSView 3 management software
PM 3000 Outlet level Outlet level Yes Yes
Serial* or
IP
Stand alone or integrated with DSView 3 management software
*Note - The serial interface option allows the PDU to connect to a supported Avocent appliance and share the
IP connection of the main appliance.
Quick Facts
• Measure and monitor voltage, current, power (kW) and energy
(kWh) consumption
• Create thresholds to generate alerts/notifications
• Remote switching capability to power on/off outlets (PM 3000
PDU models)
• Flexible installation - IP and serial interface options
• Chaining option allows multiple
PDUs to share an IP or serial connection
• Supports external, environmental sensors for measuring temperature and humidity
• Onboard data log for individual
PDU activity logs and historical data
• Can be managed directly or integrated with other Avocent solutions using the DSView® 3 management software
• Optional DSView 3 software Power
Manager plug-in for historical reporting across multiple PDUs
[Avocent Data Sheet] PM 1000/2000/3000 Power Distribution Units (PM PDUs)
Avocent can help you answer questions like:
• Do you have sufficient tools in place in order to understand the details about your current, voltage and power?
• Do you know how much power each piece of equipment is consuming?
• Do you know your energy consumption costs?
• Do you have the capability to cycle the power to your local and remote servers?
• How do you limit who has permission to power cycle equipment, and how is that activity logged?
• Do you need to provide power to high amp equipment like blade servers and larger network switches?
• When you install new equipment, how do you ensure that you have power available?
• How can you prevent overdrawing your power circuits to prevent unnecessary downtime?
• Do you need to supply a network connection for each metered PDU?
• Are you looking for tools to help justify the purchase of new energyefficient hardware?
Alarms and monitoring
Thresholds can be created to allow data center teams to know before problems occur, minimizing downtime caused by overloaded circuits. The Avocent PM PDUs deliver accurate, real-time, current monitoring of all connected devices via the Web manager,
DSView 3 software or locally through an LED digital display. Users can set a current alarm threshold that, once exceeded, will cause the PM PDU to sound an alarm, send a notification message or both.
Flexible management options
Avocent PDUs can be combined with an ACS 6000 advanced console server or MergePoint Unity®
KVM over IP and serial console switch appliances to provide faster problem solving by integrating system access and power control in a single interface. Now you can see the remote devices and control their power using an integrated approach that allows you to actually see the remote device as it powers up or reboots. This integration provides instant feedback when critical issues are being resolved remotely.
DSView 3 management software integration
The DSView 3 software provides access and control to nearly all equipment found in today’s data centers. The DSView 3 software Power
Manager plug-in extends the capability of the DSView 3 software by giving companies the ability to monitor and measure IT energy consumption, costs and trends across all levels within their data centers and remote locations. With the PM PDUs, this information allows a professional to look at individual devices, a rack of equipment or a row of equipment and group items together to view overall consumptions, capacity and costs across many locations or just a single device.
Measure both power and energy consumption
Many PDUs measure the available current at the strip level to ensure the integrity of power to the attached equipment. The PM PDUs also provide additional measurements in order to measure the energy consumption at the strip level (PM 1000 PDU models) or down to individual outlets (PM 2000 and PM 3000 PDU models). This energy measurement allows companies to implement chargeback policies, more accurately budget for expansion and measure the financial impacts of any changes.
Environmental sensor support
To get even more capabilities out of the PM PDUs, environmental sensors can be added to measure conditions at several locations within a rack. These sensors include chaining capabilities to enable a single PDU to support up to six sensors in order to measure temperature and humidity. Thresholds and alerts allow early detection to avoid downtime and equipment damage.
Features and benefits
• Outlet-Level, Phase-Level and Strip-Level Metering with Threshold/Alert
Capabilities – Provides preemptive notification of any impending overload issues before they occur and simplifies the task of installing new equipment
Note - measurement resolution +/- 5%
• Capability to Remotely Switch Outlets Through Onboard Web Interface,
DSView 3 Management Software – Allows power to hung up IT equipment to be recycled, turned on or turned off remotely for faster resolution time (not available on
PM 1000 or PM 2000 PDUs)
• Onboard Web Interface – Can be installed for direct access right out of the box or it can be configured as part of a larger integrated solution using the DSView 3 management software
• IP and Serial Interface Options – Options to install by connecting directly to the network or save IP connections by using the serial interface to connect directly to
Avocent appliances already connected to the network
• Daisy Chaining – Saves the number of IP addresses or console/KVM ports that are required to manage all power distribution needs
• Integration with DSView 3 Management Software – Single interface for management of IT equipment and PDUs simplifies mapping of outlets to servers and other equipment in order to reduce and minimize power cycling the wrong equipment
• Integration with DSView 3 Software Power Manager Plug-In – Track historical trends to measure and monitor IT power consumption, capacity and cost in order to understand what issues exist and to make more informed decisions in the future
• Electronic Overcurrent Protection (OCP) – An added layer of protection that is activated in the event of minor overloads; during such events, outlets are turned off first instead of the primary OCP tripping
• Sequential Startup – Protects integrity of all upstream electrical infrastructure by staggering the inrush current draw of all plugged-in devices
• Supports Environmental Sensors – Chain up to six environmental sensors per PDU to measure and monitor temperature and humidity at several different points within the rack for notification of any impending environmental issues
Daisy Chain
Environmental
Sensors
Environmental
Sensors
Specifications
ENVIRONMENTAL SENSOR
Physical Dimensions (W x D x H)
3 x 3 x 1.5 in. (7.6 x 7.6 x 3.8 cm)
Temperature Sensor
Range: -45° to +115°C
Accuracy: 1°C
Humidity Sensor (PMHD-THS only)
Range: -0 - 100%
Accuracy: 2%
Daisy Chaining Capability
Up to 3 sensors per PDU sensor port
External Power Required
No
Cable Type
Standard CAT-5 Patch Cable
Maximum Cable Length
1200 ft. (between the PDU and the last sensor in the daisy chain)
PM 3000/2000/1000 PDU firmware compatibility
Version 1.3.0 and higher
HARWARE
Weight
3- and 6-outlet horizontal models:
27.3 lbs. without power cord
10-outlet horizontal models:
5.2 lbs. without power cord
24-outlet vertical models:
14.8 lbs. without power cord
20-outlet vertical models:
11 lbs. without power cord
Physical Dimensions (W x D x H)
3- and 6-outlet horizontal models:
17 x 8.272 x 1.719 in. (43.2 x 21 x 4.4 cm)
10-outlet horizontal models:
17 x 5.5 x 1.7 in. (43.2 x 14 x 4.3 cm)
24-outlet vertical models:
2.2 x 3.15 x 66 in. (5.6 x 8 x 167.6 cm)
20-outlet vertical models:
2.2 x 3.2 x 52 in. (5.6 x 8.1 x 132.1 cm)
Note: PM 1000 PDU height is 46 in. (116.8 cm)
Environmental
Operating Temperature: 50° to 113°F
(10° to 45°C)
Storage Temperature: -40° to 149°F
(-40° to 65°C)
Network Connection
Number: 1
Type: 10/100/1000 Ethernet
External Sensor Connections:
Number: 2
Type: RJ-45
Accessories Included
Rack-mount kit, toolless-mounting hardware with vertical models and outlet retention clips
Warranty
Two Years
Communications options supported
Browser, CLI, SNMP, Serial or IP (using DSView 3 software or supported Avocent appliances)
Standards
Approved Agency: UL, FCC, cUL, CE, VCCI,
C-Tick, CB
[Avocent Data Sheet] PM 1000/2000/3000 Power Distribution Units (PM PDUs)
ORDERING DETAILS
PM 1000
PART NUMBER
PM 2000
PART NUMBER
PM 3000
PART NUMBER
NUMBER
OF
OUTLETS
TYPE OF
OUTLETS
RATED
AMPS
MAXIMUM
CONTINUOUS
AMPS**
INPUT
VOLTAGE
INPUT POWER
CORD TYPE
North America – Horizontal Models
PM2001H-401
PM2002H-401
PM1009H-401
PM1011H-xxx*
PM2005H-403
PM2005H-404
PM2006H-401
PM2007H-401
PM2009H-xxx*
PM3001H-401
PM3002H-401
PM3005H-403
PM3005H-404
PM3006H-401
PM3007H-401
PM3009H-xxx*
6
6
3
6
6
10
10
IEC C19
IEC C19
IEC C19
IEC C19
IEC C19
IEC C13
IEC C13
30A
30A
50A
60A
30A
30A
20A
24A
24A
40A
48A
24A
24A
16A
1-PH 208V
3-PH 208V
3-PH 208V
3-PH 208V
3-PH 208V
1-PH 200-240V
1-PH 100-240V
L6-30P
L15-30P
HUBBELL CS8365C
IEC309
L21-30P
L6-30P
Detachable cord with
IEC 320-C20 inlet
North America – Vertical Models
PM1001V-401
PM1008V-401
PM1003V-401
PM1004V-401
PM1002V-401
PM1012V-401
PM1014V-xxx*
PM2001V-401
PM2002V-401
PM2005V-403
PM2005V-404
PM2006V-401
PM2010V-401
PM2012V-xxx*
PM3001V-401
PM3002V-401
PM3005V-403
PM3005V-404
PM3006V-401
PM3010V-401
PM3012V-xxx*
24
24
24
24
24
20
20
(21) C13 and (3) C19 outlets
(21) C13 and (3) C19 outlets
(21) C13 and (3) C19 outlets
(21) C13 and (3) C19 outlets
(21) C13 and (3) C19 outlets
IEC C13
IEC C13
30A
30A
50A
60A
30A
30A
20A
24A
24A
40A
48A
24A
24A
16A
1-PH 208V
3-PH 208V
3-PH 208V
3-PH 208V
3-PH 208V
1-PH 200-240V
1-PH 100-240V
L6-30P
L15-30P
HUBBELL CS8365C
IEC309
L21-30P
L6-30P
Detachable cord with
IEC 320-C20 inlet
International – Horizontal Models
PM1010H-401
PM1011H-xxx*
PM2003H-401
PM2004H-401
PM2005H-406
PM2008H-401
PM2009H-xxx*
PM3003H-401
PM3004H-401
PM3005H-406
PM3008H-401
PM3009H-xxx*
3
6
6
10
10
IEC C19
IEC C19
IEC C19
IEC C13
IEC C13
32A
16A
32A
32A
16A
32A
16A
32A
32A
16A
1-PH 220/230/240V
3-PH 380/400/415V
3-PH 380/400/415V
IEC309
IEC309
IEC309
1-PH 220/230/240V
1-PH 100-240V
IEC309
Detachable cord with
IEC 320-C20 inlet
International – Vertical Models
PM1005V-401
PM1006V-401
PM1007V-401
PM2003V-401
PM2004V-401
PM2005V-406
PM3003V-401
PM3004V-401
PM3005V-406
24
24
24
(21) C13 and (3) C19 outlets
(21) C13 and (3) C19 outlets
(21) C13 and (3) C19 outlets
32A
16A
32A
32A
16A
32A
1-PH 220/230/240V
3-PH 380/400/415V
3-PH 380/400/415V
IEC309
IEC309
IEC309
PM1013V-401
PM1014V-xxx*
PM2011V-401
PM2012V-xxx*
PM3011V-401
PM3012V-xxx*
20
20
IEC C13
IEC C13
32A
16A
32A
16A
* Note- Actual part numbers for these models include a specific country code. Please review the chart below for the list of available options.
** Note-Maximum Continuous amps shown for North American models are derated 20% for North American safety codes.
1-PH 220/230/240V
1-PH 100-240V
IEC309
Detachable cord with
IEC 320-C20 inlet
COUNTRY CODE/POWER CORD OPTIONS (FOR MODELS WITH DETACHABLE POWER CORDS)
PART NUMBER SUFFIX
-001
-101
-105
-102
-201
-103
-202
-104
POWER CORD TYPE
L6-20P
L6-20P
L6-20P
BS1363
BS1363
GB1002/2099
CEE 7/7 VDE
CEE 7/7 EK
COUNTRY SOLD
US, Americas
Taiwan, Thailand
Japan
Singapore, Malaysia, Hong Kong
Ireland, UK
China
Continental Europe
S. Korea
Avocent, the Avocent logo, DSR, DSView and MergePoint are trademarks of Avocent Corporation or its affiliates in the US or other countries. All other marks are the property of their respective owners. © 2010 Avocent Corporation. All rights reserved. 0310-PM1K2K3K-DS-EN
Herunterladen