Sentinel Dual
Low Power
1-3 kVA
Single-phase
Highlights
• Simplified installation
• Installation versatility
• Low running costs
• Runtime expandability
• Low noise output
• On-line (VFI)
6
SENTINEL DUAL is a new range of high density double conversion on-line
UPS, suitable for powering a wide range of devices including servers, storage systems, telephony equipment - VoIP, network, medical and industrial systems.
SENTINEL DUAL are ideal for powering and protecting Blade Server systems with high input power factor.
At only 2U, SENTINEL DUAL is ideal for
19” rack cabinet installations.
SENTINEL DUAL has a practical, modern design and includes several performanance advantages over traditional on-line UPS. All developed by the Riello UPS research and development team.
The newly-designed inverter is one of the best energy conversion systems on the market, with a 0.9 output power factor and
92% opersting efficiency in on-line mode.
For critical applications requiring long battery rutnimes, extension packs and ER versions with larger battery chargers are available.
As an ECO UPS product, SENTINUAL
DUAL is also fitted with a shut-off button to reduce energy consumption to zero during prolonged periods of inactivity.
Simplified installation
• SENTINEL DUAL can be installed as a tower or in 19” rack cabinets, by simply removing and rotating the mimic panel
• Low noise (<40dBA) thanks to a high frequency switching inverter and load-dependent digitally controlled ventilation.
• Features guaranteed up to 40°C (the components are designed for high temperatures and thus subject to less stress at normal temperatures)
• On SENTINEL DUAL models, the output sockets can be programmed to disconnect less critical loads during blackouts (Power Share function).
• Frequency converter (50 or 60 Hz)
• Multi-platform communication for all operating systems and network environments; supervision and shutdown PowerShield 3 software for
Windows operating systems 7, 2008,
Vista, 2003, XP, Linux, Mac OS X, Sun
Solaris, VMware ESX and other Unix operating systems.
• Standard UPS Tools software supplied for configuration and customisation
• RS232 serial port and opto-isolated contacts
• USB Port
• Slot for communication boards such as
Modbus/Jbus, TCP/IP, SNMP and relay contacts
Installation versatility
SENTINEL DUAL can be used in a tower or rack format, by simply turning the display and adding the supplied feet or optional runners.
Emergency function
This configuration is designed for emergency systems incljuding lighting, fire detection/exit systems and alarms.
When the mains power supply fails, the inverter begins powering the loads with a progressive start (Soft Start) in order to prevent overload.
Reduced running costs
The UPS is highly flexible and easy to configure. Programmable functions can be set using the software supplied or manually via the front mimic panel.
SENTINEL DUAL can be configured in the following operating modes:
• On-line Mode: maximum protection and output voltage waveform quality
• ECO Mode: to increase output (up to to
98%), using Line Interactive operation.
• Smart Active Mode: the UPS automatically decides upon the best operating mode based on the quality of the network - On-line or Line interactive.
• Back-up Mode: the UPS can be selected to function only when the mains power supply fails.
High quality output voltage
• Even with non-linear loads (loads with a crest factor of up to 3:1)
• High short circuit current on Bypass
• High overload capacity 150% on inverter (even with mains failure).
• Filtered, stabilised and reliable voltage
(On-line double conversion technology
(VFI compliant with EN62040-2 class
C1) with filters for the suppression of atmospheric disturbances.
• Power factor correction: UPS input power factor, close to 1 and sinewave current absorption
High battery reliability
• Automatic and manual battery test
• Batteries are user replaceable without interruption to the load (Hot Swap)
• Unlimited extendible runtime using matching battery boxes.
Reduced noise
Thanks to the use of high frequency components and load-based fan speed control, the noise produced by the UPS is less than 40dB.
Other features
• Output voltage can be selected using software (220-230-240V)
• Auto-restart when mains power is restored (programmable via software)
• Stand-by on Bypass: when the UPS is switched off, it automatically goes into bypass and battery charging mode
• Minimum load switch-off
• Battery discharge warning
• Start-up delay
• Total microprocessor control
• Automatic bypass without interruption
• Status, measurements and alarms available on standard, backlit display.
• UPS firmware updating via PC
• Input protection through resettable thermal switch (versions up to 1500VA)
• Standard Back-feed protection: to prevent energy from being fed back to the network
• Manual switching to bypass.
2-YEAR WARRANTY
1. Remove the mimic panel 2. Rotate the mimic panel and insert it into position
3. Rotate the UPS 90° 4. Attach the rack supports
90°
90° www.riello-ups.co.uk
45
46
SDH 1000
BBX
INPUT SOCKET THERMAL INPUT
PROTECTION
SDH 1500
EMERGENCY
SWITCH DEVICE
(ESD)
BATTERY
EXPANSION
OUTLET
OUTPUT
SOCKET
MAINS
INPUT
SDH 2200/2200ER
3000/3000 ER
SERIAL
RS232
USB PORT
Details
OPTIONS
• Universal rails for installation in rack cabinets
• Multipass 16 bypass (mm/kg): 2U x 438 x 360 - rack 6.8 version weight
MODELS models sdH dimensions (mm)
BB SDH 36-A3 / BB SDH 36-M1 sdH 1000
Battery box
BB SDH 72-A3 / BB SDH 72-M1 sdH 2200-3000
87
425
87
625
MODELS
PoWeR inPuT nominal voltage voltage range without battery intervention max allowable voltage nominal frequency frequency range
Power factor current distortion
By Pass voltage tolerance frequency tolerance ouTPuT voltage distortion with linear load / with non-linear load frequency static variation dynamic variation
Waveform current crest factor eco mode and smart active output
BaTTeRies
Type charging time oveRload Times
100% < load < 110%
110% < load < 150% load > 150% oTHeR feaTuRes net weight (kg) gross weight (kg) dimensions (hwd) (mm)
Packaging dimensions
(hwd) (mm) surge protection
Protection devices communication input sockets output socket compliance with standards ambient temperature
Relative humidity colour noise level standard equipment provided
SDH 1000
1000va/900W
SDH 1500
1500va/1350W
SDH 2200
2200va/1980W
220-230-240 Vac
140 Vac < Vin < 276 Vac @50% LOAD / 184 Vac < Vin < 276 Vac @ 100% LOAD
300 V
50 or 60 Hz ±5Hz
50 Hz ± 5% / 60 Hz ± 5%
> 0.98
≤7%
< 2%
Selectable: 50 Hz or 60 Hz or automatic selection
± 1%
≤ 5% in 20 msec.
Sinusoidal
3 : 1
98%
1 minute
SDH 2200 ER
2200va/1760W
200 - 253 Vac
VRLA AGM lead acid maintenance free batteries
2-4 hours
4 seconds
0.5 seconds
SDH 3000
3000va/2700W
Frequency selected (from ±0.5Hz to ±5Hz configurable)
SDH 3000 ER
3000va/2400W
17.5
21
18
21.5
87x450x425 (2Ux19”x425)
245x550x600
30.5
35
15
19.5
31
35.5
87x450x625 (2Ux19”x625)
245x600x760
15
19.5
300 joule
Overcurrent - short-circuit - overvoltage - undervoltage - thermal - low battery discharge protection
USB / DB9 with RS232 and contacts / Slot for communications interface
1 IEC 320 C14 1 IEC 320 C20
8 IEC 320 C13 8 IEC 320 C13 + 1 IEC 320 C19
Safety: EN 62040-1 and Directive 2006/95/EL; EMC: EN 620040-2 category C2 and Directive 2004/108/EL
0°C / +40°C
< 95% non-condensing
Black
< 40 dBA @ 1 m
Power cable, serial cable, USB cable, safety manual, quick start, software on CD-ROM www.riello-ups.co.uk