SPM-15 Selective Level Meter for the frequency range 50 Hz to 10 MHz, send section available IEEE 488 ® Selective and wideband measurements ® Synthesizer for high accuracy and stability of tuned frequency e Frequency is set quasi-continuous!y Search-scan, AFC Analog or digital level display with autoranging; resolution 0.01 dB Absolute and relative measurements Automatic level calibration Fast signal detector, AFC Integral demodulator and loudspeaker A.C. line and battery operation Compact, handy, light Version BN 955/02: e Measures noise, reading in dBrnC e Connectors for WECO male connectors The SPM-15 Selective Level Meter is used for level measure- ments on balanced and coaxial FDM systems, at the baseband of radio-link and satellite systems with up to 1872 channels and also in single voice-channels and sound programme channels. Because the SPM-15 is compact, robust and can be battery powered it is ideal for the servicing and maintenance work car- ried out on postal systems, on railways and on the networks of public utility companies supplying energy. The SPM-15 is par- ticularly effective for detecting spurious signais, or for long-term monitoring applications. As the SPM-15 is accurate, flexible and remote controllable, it can be used during the development, production and testing of system components. When the send section is fitted, a com- plete measuring setup for loss and gain measurements is formed. The PS-15 Level Generator is available for measure- ments at different send and receive frequencies, and for end- to-end measurements. Frequency conditioning in the SPM-15 is carried out in a synthe- sizer with an especially high spectral purity, accuracy and stability. The frequency can be tuned continuously, by incre- ments or automatically (search-scan). The frequency is shown on an LED display with a resolution of 1 Hz. The receive level can be displayed on a meter or digitally with greater resolution. The automatic level calibration and linearity check ensure a high accuracy of measurement. If re- quired, the Level Meter can be delivered with a tracking genera- tor, (inclusive batteries) or, alternatively, with the Interface Bus <IEC 625>/1EEE 488 for control by a computer. Frequency range ........ . 50 Hz to 10 MHz Frequency adjustments . . . . ..... quasi-continuous, by increments or search-scan Error limits of the frequency +3x 1078 Display range (Z, = 75 Q) selective . . . . . .. — 140 to + 20 dB/— 130 to +20 dBm wideband —60 to + 20 dB/—50 to + 20 dBm 25 Hz”, 1.74 kHz, 3.1 kHz * 100 Hz on request Input impedance coaxial . . ......... 75 Q, high impedance balanced 124, 150 (135), 600 Q, high impedance Intrinsic harmonicratio . . . . ........... =80dB Send level range (with PSE-15) . . . . —60to + 11dB/dBm Further characteristics and applications e Switch-selectable bandwidths: Pilots, carrier leaks, or frequency spectra can be investigated using the narrow 25 Hz filter. On the other hand, weighted noise measure- SPM-15 Level Meter, BN 955/01 e High frequency accuracy: The small deviation of 3 x 10 from the set frequency means that the frequency selected is also accurate at high frequencies, e.g. when measuring pilot levels or carrier leaks. The error stated is valid in the rated range of temperature and includes ageing of the reference crystal. Search-scan: This facility is used to rapidly locate hot tones or discrete impairments whose level exceeds a set threshold. The scan speed is set automatically for the selec- ted bandwidth. Automatic frequency control (AFC): Ensures exact tuning to frequency under test. Operates in selective mode and analog level display only. Automatic level calibration: Ensures high measuring accuracy in the selective mode, by using a tracking calibra- tion signal which has the same frequency as the tuned fre- quency. This signal is switched into the signal path at regular intervals or when important setting parameters are altered. Digital and analog level display: The digital display has a resolution of 0.01 dB when autoranging is used. When the analog display is used (overview measurements, align- ments) the 20 dB range or the expander with a range of +1 dB can be selected. Absolute and relative level measurements: The absolute level (in dB or dBm) can be stored as a reference level so that the deviations from this value in subsequent measurements can be read off on the digital or analog ments can be carried out in single voice channels at the car- rier frequency level using a 1.74 kHz effective noise band- width filter. A flat 3.1 kHz filter for measurements over the whole channel bandwidth (e.g. via the demodulator output) can also be switched in. The SPM-15 can be equipped with a 100 Hz bandwidth filter in place of 25 Hz to facilitate measurements on FM 120 VFT systems. Remote control: All important functions can be remote controlled using the remote control board option. The board complies with IEC 625/1EEE 488. The board is fitted in the back panel instead of the BAZ- 15 Battery Pack. If you have to perform rapid level measurements or to handle large amounts of data (e.g. system monitoring), we recom- mend the use of the SPM-19 Selective Level Meter (50 Hz to 25 MHz). BCI-1 Barcode Interface (accessory): All the important device functions can be remote-controlled without using an external computer. The BCI-1 converts barcodes into the corresponding IEC bus commands. A generator program for DOS computers with matrix or laser printers is included. Economical design: Depending on the application, the SPM-15 can be used with the PSE-15 Send Section (same send and receive frequency), or with the PS- 15 Level Gener- ator (translator and distortion measurements) to form a measuring setup. SPM-15 Level Meter, BN 955/02 like version BN 955/01, but also has — built-in tracking generator (PSE-15) — CF-channel noise displayed in dBrnC — 75, 124, 135 and 600 © impedances — Femaie WECO connectors display. This simplifies both frequency response and distor- tion measurements. ® Measuring very high levels: High impedance level measurements on power-line carrier equipment and installa- tions, for example, can be carried out by connecting in the SDG-40 Balanced Attenuator (max. 30 V). Specifications for the Selective Level Meter with tracking generator SPM-15 If nothing to the contrary is stated, the data for the nominal ranges of ambient temperature, a.c. line voltage and a.c. line frequency are valid immediately after switch-on. Inputs Display ranges + - + oh » Coaxialinput*. . . . .. Versacon 9 Universal Connector Input Selective Wideband " System suitable for all usual connector types dB BN 955/02: fem. connector for WECO 358 A male connector до = 75 © - br © 1 al 0 © O a Inputimpedance, switchable . . . . 75Q and highimpedance > Fr ncyrange .. .. ........... 50 Hzto 10 MHz 2, = 124, 150 © — 120 10 +20 dBm 40 to +20 dBm Co a Z, = 600 Q —130 to +20 dB/dBm | —50to +20 dB/dBm Balancedinput ............ 3 pole CF connector Input impedance, switchable 124, 150 Q and high impedance BN 955/02: only 124 Q tem. connector tor WECO 372 A/379 A male connector Frequency range . . . . . . . ...—.. . 6kHzto 10 MHz Signal balance ratio as per CCITT O.121, f=6kHzto 1MHZ . ... .. .. =40dB Returnlossatf = 100kHz =40dB Inputimpedance, switchable . . 600 Q and high impedance BN 955/02: also 135 Q2 135 Q fem. connector for WECO 241 A male connector 600 Q fem. connector for WECO 310 male connector Frequencyrange . . . . . . ......... 50 Hz to 620 kHz Signal balance ratio as per CCITT 0.121 . . ...... =40dB Returnloss atf = 10 kHz =50 dB Tolerable input voltage for atl inputs Overload limit when terminated withZ,,V, ms . . . . . . . 10V Tolerable d.c. voltage at high impedance input + We + 2 a4 & = a x a =m » = Frequency Frequency settings Manual quasi-continuous adjustment over the whole range without switchover, resolution . . . . . . . . . .. ... 1Hz also by increments with variable increment width and automatic search-scan. Stopped by signal detector. Automatic frequency control (AFC) operating in selective mode and analog level display. Synchronous tuning of the PS-15 Level Generator can also be carried out. Frequencydisplay..........., 7 digits with LED Error limits for the tuning frequency including ageingoverayear . . . . . . . .......... +3x 107° Level display Display of power level (dBm) referred to . 1MW of voltage level (dB) referredto . . 0.775V the level difference between an absolute and a stored reference level! . . . . . . . dB Noise level (dBrnC) with Option BN 955/00.23 instead of noise voitage level 1) OdBrnC = 90dBm Display, switchable . . . . ....... Digital display, resolution . . . . . . . . Analog display viameter, ranges . . . . . . digital or analog .... 0.01dB + 1 dB and 20 dB Fast signal detector with LED Activation threshold on the 20 dB scale . approx. — 15 dB (= — 10 dB) *) “Inputs” describes the impedances for BN 955/02 1) In analog measurement mode, the lower limit is 10 dB less Measurement range selection Autoranging for digital display Manually in steps of 1 dB or 10 dB fcr analog display Measurement errors Selective measurements for Zin = Zou = Z, and automatic level calibration Error limits of level display for 0 dBm (dB) input level, display digital or analog (+1 dB scale), f= 10 kHz (100 kHZ at Z, = 124, 150 ©), bandwidth 1.74 and 3.1 kHz Coaxial | Bal. inthe range (23 £3)°C . . +0.06 dB | +0.1 dB inthe range Oto +50°C . . ++ *0.15dB | +0.2 dB Additional error for any input level coaxial input +20 0 dBm -70 - 90 —100 -110 | +0.15 dB +0.1d8 | :0.15dB | +0.3d8 | +1d8” | +20 0 dB —80 - 100 -110 —120 balanced input 0.15.08 | +0.1dB 1 1 +20 0 dB/dBm - 65 - 85 —95 - 105 *) Error limits only apply 10 the 25 Hz bandwidth. | +0.15dB | +0.3d8 | +1d8" F T 1 The variation of level display with frequency referred to 10 kHz (100 kHz at Z, = 124, 150 Q), for input levels at least 40 dB greater than intrinsic noise (values in dB). Z,=750 | +03 | +0.08 2, = 124, 150 0 — | +04 | 10.15 2, = 600 @ | +08 [+025] +0.15 [-025| — I 1 r 1 T I 50 200 2 6 60 100 620 10 Hz kHz MHz Additional error for analog display 20 dB scale, intherange —10to +2dB . . . . . . . ....... +0.3dB Wideband measurements Overall error in the range 0 to +50°C, Zin = Zou = Zo and after calibration Input *! Level range Error limits Zo = 75 Q — 50 to +20 dB/ —40 to +20 dBm 10.6 dB Zo = 124, 150 2 | -40to +20 dB/-30 to + 20 аВт +0.7 dB Za, = 600 Q —40 to +20 dB/dBm +0.7 dB “) See “inputs” for impedances for BN 955/02 Selectivity The bandwidths are switchable between: Bandwidth 25 Hz” 174kHZ” | 3.1kHz | Eff. noise bandwidth (+10%) | — 1.74 kHz? | 3.1kHz | Distance Af from =3d8 +7 Hz +650 Hz + 1.5kHz centre frequency for =50 dB +80 Hz — — an attenuation of =60 dB +250 Hz +2 kHz +2 kHz 1) Values apply to a temperature range of + 5 to +40°C 2) 1.95 kHz for BN 955/02 100 Hz bandwidth for BN 955/01 and /02 in place ot 25 Hz for BN 955/04 as additional external filter Bandwidth, attenuation =3dB . . 100 Hz + 5 HZ attenuation = 18 dB + 100 Hz attenuation = 60 dB + 400 Hz Image frequency rejection and IF suppression =70dB Harmonic ratio a, ay, level of the fundamental =0 dB/dBm with automatic calibration, frequency of the fundamental FZ3kHZ . ... . =80dB f =300 Hz (bandwidth 25 Hz) . . . =70dB Noise power ratio (NPR) when loaded with noise having the bandwidth 12 kHz to 8160 kHz, wideband level —25 to + 10 dBm, slot anywhere in the band with By = 20 kHz, bandwidth 1.74 kHz (1.95 kHz) and with automatic calibration =54 dB EEE EEE E EN Noise floor Intrinsic noise and discrete spurious signals, selective, bandwidth 25 Hz, input terminated with Z,, f = 3 kHz Input75Q . . <— 135 dB (- 125 dBm) Input 124, 150 Q (f =6kHz) . . . . . . <— 125 dB (- 120 dBm) Input 135, 600 Q ........ 1100 <—120 dB/dBm When the bandwidths 1.74 kHz (1.95 kHz) and 3.1 kHz are used, the level values increase by +10 dB. Additional outputs Demodulator output 3 pole CF connector . . . ........... Zon = 600 9 BN 955/02: fem. connector for WECQO 310 male connector SSBdemodulation . . . ... erect/inverted position Frequency of the translated channel when tuned to channelcarrier . . . ..... Oto 4kHz A.C. voltage output (BNC), short circuit proof (not fitted to BN 955/04) Output level for Zou = Z = 75 Q and OdBrangedisplay LL 211141 LL 0 dBm Output frequency, operating mode, selective . . .. 10kHz wideband . . as input signal D.C. output 3 pole CF connector o Zo => 5kQ Open-circuitvoltageforf.s.d. .. .. ........ +5V Outputforinternal standard frequency (BNC) . .. 10MHz Control output for external tuning (BNC) of the PS-15 Level Generator, frequency range .. ... 1.221241 4110 40to 50 MHz Options PSE-15 Tracking Generator, BN 955/00.02 (Standard in BN 955/02 and BN 955/04) Frequencyrange, adjustmentanddisplay. . Generator outputs Coaxial output, fem . . Outputimpedance Return loss at 10OKHz . . Balanced output, fem. . . . Output impedance, . . same as Level Meter . . same as Level Meter ‚ 7/5 2 =50dB . . same as Level Meter switchable . . . . . 600, 150, 124 Q, approx. 15 Q BN 955/02: 600, 135, 124, approx. 15 Q Return loss atf = 100kHzor 10kHz (600Q) . . . . . . =36dB Signal balance ratio as per CCITT O.121 =40dB Send level Send level is displayed digitally by pressing abutton, resolution . . ...... 0.1dB Send level range Coaxial Ze = 752 —55 to +12 dBm —65 to +3 dB = | — ‚9 dB Balanced 2, = 124 © 58 to +9.9 dBm 6510 +3 dB Z,=150Q | -59to +9 dBm Z, — 135 9 "| -58 to + 9.5 dBm —65 to +3 dB Balanced Z,= 6000 65 to +3 dBm —65 to + 3 dB Za = Ô —59 to + 11 dBm -59 to + t1 dB 1) BN 955/02: instead of 150 Q Level adjustmentinstepsof . . . . 5dBor0.1dB Error limits of the send level for Zou = Zi = Zo OF Zaun — 0.2. = Z, 2, = 75 © +0.6 dB | +0.25 de 7, = 124, 1500 — | -0.3 dB 2, = 600 © _ __ 7 _2, | !0698 +0.3 dB ~0.4 dB 27. = 600 © N _ 7 oz -z| +068 +0398 ~0.6 dB 1 50 200 Hz 6 100 620 kHz 10 MHz Intrinsic harmonic ratio a, and a, f=50Hzto 10MHZ . ..... ..... =40 dB Attenuation of discrete nonharmonic spurious signals, at least 50 dB below wanted signal. BAZ-15 Battery Pack”, BN 955/00.01 Operatingtime . . .......... . approx. 5h Chargingtime . . . . ........... . approx. 14h Interface Bus <IEC 625>/IEEE 488”, BN 955/00.04 Interface functions . . . . . SH1,AH1, T6, L4, SR1,RL1, PP2, DC1, DT1, CO Measurement times if level changed (x = measurement range) withinx+1dB . . . . ............ typically 2 (2.3)s X+ 100B .............. typically 3.3 (3.6)s additionally (due to calibration clock) . . . . typically 1.9(2.3)s (values in parentheses refer to 25 Hz bandwidth) Default high impedance", BN 955/00.25 Input switches to high impedance after power interruption or change of impedance. General Specifications Power supply A.C. line Nominal ranges of use for a.c. line voltage, switchable . . . 110/117/127/220/227/237V, —12to + 10% Nominal range of use for a.c. line frequency . . . 47.5t063 Hz Power consumption, measuring orcharging . . approx. 38 VA Safety class as per IEC 348 and VDE 0411. ...... Class | Battery powered from BAZ-15 Battery Pack, BN 955/00.01. Ambienttemperature Nominalrangeofuse .. ..... . 010 +55°С Limits operating range .. - ...... —10to +55°C Ordering Information Level Meter SPM-15* BN 955/01 Level Meter SPM-15 with Tracking Generator PSE-15, BN 955/02 noise measurements in dBrnC ”, and WECO connectors Level Meter SPM-15 BN 955/04 same as BN 955/02, 75/124 Q connectors: WECO 558 A Option (included in price) Default high impedance BN 955/00.25 Options (at extra cost) Tracking Generator PSE-15” (for BN 955/01) BN 955/00.02 Battery Pack BAZ-15, rechargeable“ BN 955/00.01 Interface <IEC 625> board * BN 955/00.04 with IEEE 488 connector and K 420 cable 100 Hz bandwidth BN 955/00.09 for BN 955/01 and /02 in place of 25 Hz 100 Hz bandwidth BN 955/00.06 for BN 955/04 as additional external filter Storage andtransportation. .. .. .. ... —40 to + 70°C * *) with BAZ-15 Battery Pack, BN 955/00.01, — 40 to +60°C Dimensions(wxhxd)inmm ‚ З17 х 175 х 342 Weight SPM-15 with PSE-15 . approx. 13kg BAZ-15 ... 121011 44 14444 44140 approx. 2.8 kg < IEC 625 > Interface Bus Card . . . German Post Office Certificate of Approval No. for SPM-15, BN 855/01 for PSE-15, BN 955/00.02 approx. 1kg 272 181 826-5 272918 104-5 for BAK-15, BN 955/00.01. ......... 191090 156-0 BN 955/00.21 Noise measurements in dBrnC”' (tor BN 955/01) ВМ 955/00.23 Accessories (at extra cost)” BCI-1 Barcode Interface BN 3005/10 for SPM- 15 with IEC bus board Return Loss Measuring Attachment RFZ-12 BN 810/01 200 Hz to 4.5 MHz Signal Balance Ratio Measuring Attachment SDZ-12 BN 811/01 200 Hz to 4.5 MHz Impedance Magnitude Measuring Attachment SFZ-1 BN 385/04 300 Hz to 612 kHz SDG-40 Balanced Attenuator BN 608/00.01 IEEE 488/1EC 625 (plug) adaptor S832 Protective Transportation Cover SD-940 (1 set) BN 960/00.02 19” conversion kit BN 955/00.11 1) Factory installed. Order with instrument. 2) has bandwidth of 1.95 kHz instead of 1.74 kHz 3) The BAZ-15 and the Interface Bus cannot be used at the same time 4) For specifications and more ordering information see the Specification Sheet “Measuring Accessories”. Accessories suitable for BN 955/01. "Equipped with the 75 Q basic connector Versacon™ 9 and BNC adaptor. For other adaptor types, see “Specification Sheet Versacon® 9", and order chosen type when ordering instrument.
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement