- No category
advertisement
▼
Scroll to page 2
of 4
TRANSPAK™ T713 RTD Input Isolating, Field Configurable Two-Wire Transmitter Provides an Isolated, Linearized Current Loop in Proportion to a 3-Wire Pt100 RTD Input T713-0000 T713-0013 (-200°C offset) Field Configurable, Switch Selectable Input Ranges Eliminates Ground Loops Wide Ranging Zero & Span Integral RTD Linearization/Output Linear to Temperature FM Safety Approval for Hazardous Installations Description The T713 series has 6 widely adjustable input ranges and 2 output ranges, all of which are field selectable via top accessed DIP switches. The T713 provides 600VDC of isolation with outputs of either 4-20mA or 10-50mA. Current outputs are linear to temperature. Urethane coating of internal circuitry for protection from corrosive atmospheres is included as standard. Application The T713 is useful in any application requiring isolation of a 2-wire loop current from a 3-wire RTD. Typical applications include SCADA and remote data acquisition such as monitoring boiler or custody transfer/pipeline temperatures. The output of the T713 can be used to drive a digital meter for direct display or interface with a computer for monitoring and control applications. The T713 has an 80% zero and span adjustability within any user selected input range. For example, Range 1 of Table 1 specifies 0 to 1000° F with a minimum span of 200° F (1000° - 200° = 800°, or 80%). This 80% adjustability allows the user to field calibrate the unit for the maximum (0 to 1000°) down to any minimum (200°) span (e.g. 740° to 940°) - as long as that adjusted span remains within the selected 0 to 1000°F range. The same is true for any user selectable range: all spans are field adjustable from 20% (minimum span) to 100% of the specified range. The T713 is FM approved for intrinsically safe operation in Class I, Division 1, Groups A, B, C, and D; Nonincendive Class I Division 2, Groups A, B, C and D, and Classes II & III, Division 2, Group G hazardous locations when installed per manufacturer’s drawing 790-0024-00. Refer to model T805 for NEMA 4, FM/CSA/CENELEC approved explosion proof housing. Calibration Note: Factory settings are: Input: Range 1 Output: 4-20mA 1. Open the access lid on the top of the unit (see Top View Diagrams). 2. Select the output range using switch S4. The CLOSED position selects a 10-50mA output. The OPEN position selects a 4-20mA output. 3. Select the input range from Table 1 or 2 and configure switches S1 through S4. 4. Connect the input to a calibrated 3-wire resistance source and monitor the output current (refer to terminal wiring). 5. Set the calibrator to the desired minimum temperature. 6. Adjust the coarse zero rotary switch to obtain an output of approximately 4mA or 10mA. Adjust the fine zero for exact calibration. Note that it may be necessary to switch coarse zero up or down one position. 7. Set the calibrator to the desired maximum temperature and perform similar adjustments using the coarse span switch and fine span potentiometer. Top View Diagram Table 1: T713-0000 Input Ranges Switch Position Input Range (100 Ohm Pt RTD) 0.00385 alpha Input Limits Minimum Span Input Limits Minimum Span 1 0 to 600 120 0 to 1000 200 2 0 to 300 60 0 to 500 100 3 0 to 50 10 30 to 130 20 1 ¡C ¡F 1 2 3 Key: = 1 = ON or Closed Table 2: T713-0013 Input Ranges Switch Position Input Range (100 Ohm Pt RTD) 0.00385 alpha Input Limits Minimum Span Input Limits Minimum Span 1 -200 to 360 120 -300 to 700 200 ¡C ¡F 2 -200 to 85 60 -300 to 200 100 3 -200 to -155 20 -300 to -250 40 2 3 Key: = 1 = ON or Closed Field Mounting The T713 is designed for installation in industrial field environments. A sealed, diecast aluminum housing protects against corrosion, moisture, dust and electrical noise such as radiofrequency (RFI) and electromagnetic (EMI) interference. All circuit boards are urethane coated for environmental protection and FM approval. For protection against extreme moisture, hose directed water (NEMA 4) or hazardous environments, use the T805, a rugged EP/ NEMA 4 enclosure with standard, 1/2" and 3/4" FPT ports for easy hookup and operation in harsh process environments. Mounting Hardware Dimensions in millimeters (inches) T805 Field Mountable Housing (EP, NEMA 4 rated) 3/4" Hub (Includes T903 Retainer Ring & NEMA 4 Gasket) T713 Terminal Connections 1. Loop Output (-) 2. Loop Output (+) 3. RTD Exc (+) 4. RTD (+) 5. RTD (-) 6. Shield (Gnd) NOTE 1: RL represents any other device loads in the current loop. NOTE 2: For best RF and common mode rejection, ground the case (pin #6). Specifications Input Span Range (Min/Max): See Tables 1, 2 Excitation Current: 1mA, typical Leadwire Resistance Effect: 1% of span error with up to 40 Ohms/lead Output Span: 4-20mA/10-50mA, switch selectable Minimum Output Current: 3.3mA, typical Maximum Output Current: 4-20mA: 24mA, typical 10-50mA: 58mA, typical Supply Voltage Range: 4-20mA: 12 to 80VDC 10-50mA: 12 to 60VDC Maximum Change in Supply - Voltage Effect: 0.05% of span Maximum Change in Load Effect: 0.05% of span Loop Voltage Drop: 12VDC @ 20mA Linearizing Accuracy: T713-0000: ± 0.1% of standard R/T tables, typical; 0.2% max. T713-0013: ± 0.21% of standard R/T tables, typical; 0.3% max. Stability: Zero: ± 0.02% of span/°C, typical, or 2mV, whichever is greater Span: ± 0.01% of span/°C, typical Overall Accuracy (Includes Linearity, Hysteresis, Stability): ± 0.5% of any adjusted span, max. Zero and Span Adjustability: 80% of any selected range Repeatability: ± 0.05% of span, typical Response Time: 150ms, typical, 400ms max. Ordering Information Models & Accessories Specify: 1. Model: T713-0000 T713-0013 (-200°C offset) 2. Optional Custom Factory Calibration: Specify C620 with desired input and output range. Output Ripple: 0.1% of span, rms, typical RFI Effect (5W, 470MHz at 3 Ft.): <1% of span error Isolation: 600V DC maximum, input to output to case Temperature Range: Operating: -40 to 80°C (-40 to 176°F) Weight: 0.64lbs Agency Approval: FM approved intrinsically safe for hazardous locations, certificate No. J.I. 2M2A5.AX (3611). Dimensions Dimensions in millimeters (inches) Accessories M004 T902 T910 AP9046 T805 V565 C620 Snap-in Channel Track, 4 ft. (nonconducting). Mounting plate for M004, includes 4" track. Bulkhead (flat surface) mounting plate. Action Pak 24/40VDC, 65mA Power Supply. NEMA 4, explosion proof enclosure. 3-1/2 digit remote loop-powered indicator, wide ranging display, NEMA 4X enclosure, CSA & FM approval standard. Specify Option C to house Transpak. Factory calibration (user specified). Factory Assistance For additional information on calibration, operation and installation contact our Technical Services Group: 703-669-1318 Eurotherm, Inc 741-F Miller Drive Leesburg, VA 20175-8993 703-443-0000 [email protected] or www.eurotherm.com/actionio Action Instruments Barber-Colman [email protected] 721-0200-00-L 09/06 Copyright© Eurotherm, Inc 2006 Chessell Continental Eurotherm
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project