Gefran MN DataSheet
The Gefran MN series pressure transmitters are designed for use in high-temperature environments, up to 400°C. They utilize a fluid-filled system for temperature stability and employ strain-gauge technology to convert physical measurements into electrical signals. The MN series offers various pressure ranges from 0-35 to 0-2000 bar or 0-500 to 0-30000 psi. They feature high accuracy, with <±0.25% FSO for the H version and <±0.5% FSO for the M version.
โฆษณา
โฆษณา
MELT PRESSURE TRANSMITTERS
MN SERIES
Voltage output
MAIN FEATURES
• Pressure ranges from:
0-35 to 0-2000 bar / 0-500 to 0-30000 psi
• Accuracy: < ±0.25% FSO (H); < ±0.5% FSO (M)
• Fluid-filled system for temperature stability
• Mercury filling volume:
MN0 (30mm 3 ); MN1, MN2, MN3 (40mm 3 )
• 1/2-20UNF, M18x1.5 standard threads; other types available on request
• Other diaphragms available on request
• Autozero function on board / external option
• Drift Autocompensation function (SP version)
• Standard diaphragm is 15-5 PH stainless steel with
GTP+ coating
• 17-7 PH corrugated diaphragm with GTP+ coating for
ranges below 100 bar-1500 psi
GTP+ (advanced protection)
Coating with high resistance against corrosion, abrasion and high temperature
AUTOZERO FUNCTION
All signal variations in the absence of pressure can be eliminated by using the Autozero function.
This function is activated by closing a magnetic contact located on the transmitter housing.
The procedure is permitted only with pressure at zero.
AUTOCOMPENSATES INFLUENCE OF MELT
TEMPERATURE
Thanks to internal self-compensation, the MSP series transmitter cancels the effect of pressure signal variation caused by variation of Melt temperature.
This reduces at the minimum the read error caused by heating of the filling fluid (typical of all sensors built with
“filled” technology).
The MN series of Gefran, are pressure transmitters for using in High temperature environment.
The main characteristic of this series is the capability to read temperature of the media up to 400°C.
The constructive principle is based on the hydraulic trasmission of the pressure.
The fluid-filled system assures the temperature stability.
The phisical measure is transformed in a electrical measure by means the strain-gauge technology.
TECHNICAL SPECIFICATIONS
Accuracy (1)
Resolution
Measurement range
Maximum overpressure
(without degrading performances)
Measurement principle
Power supply
Maximum current absorption
Insulation resistance (at 50Vdc)
Output signal Full Scale (FSO)
H <±0.25%FSO (100...2000 bar)
M <±0.5%FSO (35...2000 bar)
Infinite
0..35 to 0..2000bar
0..500 to 0..30000psi
2 x FS
1.5 x FS above 1000bar/15000psi
Extensimetric
15...30Vdc N, C
10...30Vdc B, M
-15...+15Vdc H, L
25mA
>1000 MOhm
5Vdc (M, H) - 10Vdc (N, L)
5,1Vdc (B) - 10,1Vdc (C)
0Vdc (M, N, H, L)
0.1Vdc (B, C)
“Autozero” function
Zero balance
(tollerance ± 0.25% FSO)
Zero signals adjustment
(tollerance ± 0.25% FSO)
Span adjustment within ± 5% FSO
Maximum allowed load
Response time (10...90% FSO)
Output noise (RMS 10-400Hz)
Calibration signal
Output short circuit ingress and reverse polarity protection
Compensed temperature range
Operating temperature range
Storage temperature range
Thermal drift in compesated range:
Zero / Calibration / Sensibility
Diaphragm maximum temperature
Zero drift due to change in process temperature (zero)
See Manual
1mA
~ 1ms
< 0.025% FSO
80% FSO
YES
0...+85°C
-30...+105°C
-40...+125°C
< 0.02% FSO/°C
400°C / 750°F
0.02 bar/°C
Zero drift temperature for
Autocompensated version (SP) within the temperature range 20°C-400°C inclusive the drift temperature of the housing
Standard material in contact with process medium
Thermocouple (model MN2)
Protection degree (6-pole female connect)
< 0.003 bar/°C 100 ≤ p < 500 bar
0.0014 %FS/°C p ≥ 500 bar
Diaphragm:
• 15-5 PH with GTP+ coating
• 17-7 PH corrugated diaphragm
with GTP+ coating for ranges
<100 bar(1500psi)
Stem: • 17-4 PH
STD: type “J” (isolated junction)
IP65
FSO = Full scale output: (1) BFSL method (Best Fit Straight Line): includes combined effects of Non-Linearity, Hysteresis and Repeatability.
MECHANICAL DIMENSIONS
MN0
MN1
MN2
D1
D2
D3
D4
D5
A
B
C
Ch
[Hex]
1/2 - 20UNF
ø7.8 -0.05
[ ø0.31” -0.002
]
ø10.5 -0.025
[ ø0.41” -0.001
]
ø10.67
[ ø0.42” ]
ø12.7
[ ø0.5” ]
5.56 -0.26
[ 0.22” -0.01
]
11.2
[ 0.44” ]
15.74
[ 0.62” ]
16
[ 5/8” ]
D1
D2
D3
D4
D5
A
B
C
Ch
[Hex]
M18x1.5
ø10 -0.05
[ ø0.394” -0.002
]
ø16 -0.08
[ ø0.63” -0.003
]
ø16 -0.4
[ ø0.63” -0.016 ]
ø18
[ ø0.71” ]
6
-0.26
[ 0.24” -0.01
]
14.8 -0.4
[ 0.58” -0.016
]
19
[ 0.75” ]
19
[ 3/4” ]
MN3
Capillare esposto
Exposed capillary
D1 1/2-20UNF
D2 .307/.305”
[7.80/7.75mm]
D3 .414/.412”
[10.52/10.46mm]
A .125/.120”
[3.18/3.05mm]
B .318/.312”
[8.08/7.92mm]
C .81”
[20.6mm]
NOTE : dimensions refer to rigid stem length option “4” (153 mm – 6”)
WARNING : For installation use a maximum tightening torque of 56 Nm(500 in-lb)
ELECTRICAL CONNECTIONS
VOLTAGE OUTPUT (M, N, B, C)
Power supply 15..30Vdc
MAGNETIC
AUTOZERO
6-pin
Shield drain wire is tied to connector via cable clamp
EXTERNAL
AUTOZERO
6-pin
6 pin connector
VPT07RA10-6PT2
(PT02A-10-6P)
CONTROLLER
Supply Voltage
Supply Voltage
Signal
-
+
+
C
D
A
Supply Voltage
Supply Voltage
Signal
-
+
+
C
D
A
G
H
E
F
C
D
A
B
AMPLIF.
B
E - F
Signal
Autozero
VOLTAGE OUTPUT (H, L)
Power supply -15..+15Vdc (*)
( * ) The pin B of the connector must be connected to the common of the ± 15Vdc supply
8-pin connector
Connector
PC06A-12-88 (SR)
Connect the cable sheathing to the side of the instrument.
R-Cal
No connection
Signal
Calibration shunt
-
E + Supply voltage
S +
E -
S -
Signal
Supply voltage
Signal
Magnetic Autozero version
A = Excitation + (white)
B = Signal + (red)
C = Excitation - (green)
D = Signal - (black)
E = R-Cal (blue)
F = R-Cal (brown)
G = no connection
H = no connection
External Autozero version
A = Excitation + (white)
B = Signal + (red)
C = Excitation - (green)
D = Signal - (black)
E = Autozero (blue)
F = Autozero (brown)
G = no connection
H = no connection
B
E - F
42 [1.65"]
8 pin connector
PC02E-12-8P Bendix
AUTOZERO FUNCTION
The Autozero function is activated through a magnetic contact (external magnet supplied with the sensor).
See the manual for a complete Autozero function explanation.
ACCESSORIES
Connectors
6-pin mating connector (IP65 protection degree)
8-pin mating connector
Extension cables
6-pin connector with 8m (25ft) cable
6-pin connector with 15m (50ft) cable
6-pin connector with 25m (75ft) cable
6-pin connector with 30m (100ft) cable
8-pin connector with 8m (25ft) cable
8-pin connector with 15m (50ft) cable
8-pin connector with 25m (75ft) cable
8-pin connector with 30m (100ft) cable
Other lengths
Accessories
Mounting bracket
Dummy plug for 1/2-20UNF
Dummy plug for M18x1.5
Drill kit for 1/2-20UNF
Drill kit for M18x1.5
Cleaning kit for 1/2-20UNF
Cleaning kit for M18x1.5
Fixing pen clip
Autozero pen
Thermocouple for MN2 model
Type “J” (153mm - 6” stem)
CON300
CON307
C08WLS
C15WLS
C25WLS
C30WLS
E08WLS
E15WLS
E25WLS
E30WLS consult factory
SF18
SC12
SC18
KF12
KF18
CT12
CT18
PKIT309
PKIT312
TTER 601
Cable color code
6 wires
Conn.
Wire
A Red
B
C
Black
White
D
E
F
Green
Blue
Orange F
G
D
E
H
Cable color code
8 wires
Conn.
Wire
A White
B
C
Red
Green
Black
Blue
Orange n.c.
n.c.
ORDER CODE
M 000
Autocompensation (*)
Standard
SP
-
000= Standard version
Special or customized versions available on request
(*) available for ranges > to 100bar
(*) not available with MN3 version
OUTPUT SIGNAL
0 .. 5Vdc M
0 .. 10Vdc N
0.1 .. 5.1Vdc
B
0.1 .. 10.1Vdc
C
0 .. 5Vdc
(supply -15...+15Vdc)
H
0 .. 10Vdc
(supply -15...+15Vdc)
L
E
-
External autozero
Magnetic autozero
FLEXIBLE LENGTH
(mm / inches)
Standard (MN0)
0
Standard (MN1, MN2)
D
E
F none
457mm
Standard (MN3)
L
610mm
760mm
711mm
18”
24”
30”
28”
Standard
CONFIGURATION
Rigid stem 0
Rigid stem + flexible
With thermocouple
Exposed capillary
1
2
3
CONNECTOR
6 pin
8 pin
6
8
Available on request
A 76mm
B 152mm
C 300mm
3”
6”
12”
36” G 914mm
H 1067mm
I 1220mm
J 1372mm
K 1520mm
42”
48”
54”
60” ACCURACY CLASS
0.25% FSO
(ranges ≥ 100 bar/1500 psi)
H
0.5% FSO M
RIGID STEM LENGTH
(mm / inches)
RANGE Standard (MN0, MN1, MN2) bar
35
50
70
B35U
B05D
B07D
100 B01C psi
500
750
P05C
P75D
1000 P01M
1500 P15C
4
5
153mm
318mm
Standard (MN3)
0 none
6”
12.5”
200
350
500
700
B02C
B35D
B05C
B07C
3000 P03M
5000 P05M
7500 P75C
10000 P10M
1000 B01M 15000 P15M
Available on request
1 38mm
2 50mm
3 76mm
6 350mm
7 400mm
8 456mm
1.5”
2”
3”
14”
16”
18”
1400 B14C 20000 P20M
2000 B02M 30000 P30M
Examples
MN2-6-M-B07C-1-4-D-000
THREAD
Standard
1
4
1/2 - 20 UNF
M18 x 1.5
Melt pressure transmitter with type “J” thermocouple, 0..10Vdc output, 6-pin connector, 1/2-20UNF thread, 700 bar full scale, 0,5% accuracy class, 153 mm (6”) rigid stem, 457mm (18”) flexible capillary.
MSPM0-6-M-P03M-1-4-0-000
Melt pressure transmitter autocompensated version, rigid stem, 0..10Vdc output, 6-pin connector, 1/2-20UNF thread, 3000 psi full scale, 0,5% accuracy class, 153 mm (6”) rigid stem.
Sensors are manufactured in compliance with:
- EMC compatibility directive
Product designed and available in compliance with Directive 2011/65/EU (RoHS II) only for large-scale stationary installation or industrial tools, or for B-to-B laboratory equipments for R&D purposes
Electrical installation requirements and Conformity certificate are available on our web site: www.gefran.com
GEFRAN reserves the right to make any kind of design or functional modification at any moment without prior notice.
GEFRAN spa via Sebina, 74
25050 PROVAGLIO D’ISEO (BS) - ITALIA tel. 0309888.1 - fax. 0309839063
Internet: http://www.gefran.com
DTS_MN_07-2017_ENG
ดาวน์โหลด
โฆษณา