Lucent Technologies DMX Access Multiplexer Applications and Planning Guide
Reklama
Reklama
Metropolis
®
DMX Access Multiplexer
Release 5.1–7.0
Applications and Planning Guide
Copyright
2006 Lucent Technologies
All Rights Reserved
365-372-300
Issue 8.0
September 2006
Copyright © 2006 Lucent Technologies. All Rights Reserved.
This material is protected by the copyright laws of the United States and other countries. It may not be reproduced, distributed, or altered in any fashion by any entity (either internal or external to Lucent Technologies), except in accordance with applicable agreements, contracts or licensing, without the express written consent of the Customer Training and Information Products organization and the business management owner of the material.
For permission to reproduce or distribute, please contact the following:
Product Development Manager 1-888-LTINFO6 (1-888-584-6366)
Notice
Every effort was made to ensure that the information in this document was complete and accurate at the time of printing. However, information is subject to change.
Mandatory Customer Information
Interference Information: Part 15 of Federal Communications Commission (FCC) Rules.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residence is likely to cause harmful interference in which case the user will be required to correct the interference at their own expense.
Security statement
In rare instances, unauthorized individuals make connections to the telecommunications network through the use of remote access features. In such an event, applicable tariffs require that the customer pay all network charges for traffic. Lucent Technologies cannot be responsible for such charges and will not make any allowance or give any credit for charges that result from unauthorized access.
Trademarks
WaveStar and Metropolis family of products including DMX, DMXpress, DMXtend, DMXplore, EON, BandWidth Manager, TDM 2.5G, TDM 10G, OLS
40G, and OLS 400G are registered trademarks of Lucent Technologies.
5ESS, 7R/E, SNMS, DDM-2000 OC-3 Multiplexer, DDM-2000 OC-12 Multiplexer, DDM-2000 FiberReach Multiplexer, and FT-2000 Lightwave System are registered trademarks of Lucent Technologies.
ANSI is a registered trademark of American National Standards Institute, Inc.
Common Language is a registered trademark, and CLEI, CLLI, and CLFI are trademarks of Telcordia, Inc.
Microsoft, MS-DOS, and Windows are registered trademarks of Microsoft Corporation.
National Electric Code is a registered trademark of National Fire Protection Association, Inc.
NMA, TIRKS, and TEMS are registered trademarks of Telcordia, Inc.
Ordering information
The ordering number for this document is 365-372-300. To order this document, call 1-888-582-3688. For more ordering information, refer to “How to Order
Documents” in the section “About This Document.”
Technical Support Telephone Numbers
For SONET technical assistance, call Lucent Technologies’ Technical Support Services (TSS) at 1-866-LUCENT8 (866-582-3688). This phone number is monitored 24 hours a day.
Information Product Support Telephone Number
You can also use this telephone number to provide comments on the Metropolis
®
DMX Access Multiplexer or to suggest enhancements.
Contents
............................................................................................................................................................................................................................................................
About this information product
Reason for reissue
Safety labels
Intended audience
Intended audienceHow to use this information product
Conventions used
How to comment
............................................................................................................................................................................................................................................................
Overview of the Metropolis
®
Portfolio
Metropolis
®
Metro Access Solutions
Metropolis
®
DMXplore Access Multiplexer
Metropolis
®
DMXtend Access Multiplexer
Introduction to the DMX Access Multiplexer
Feature Release Plan
............................................................................................................................................................................................................................................................
Hardware Features
In-service Upgrades
Networking Capabilities
Cross-connection Types
Operations Features
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
C O N T E N T S i i i
............................................................................................................................................................................................................................................................
Service Applications
Established Network Evolution
Access Transport for Voice and TDM Private Line Services
Interoffice Transport
Ethernet Private Line
Multi-point Ethernet Private Line
Ethernet Rate Shaping Services
Hitless Bandwidth Provisioning with LCAS
Link Aggregation (LNW70 LAN ports)
Virtual LAN Services
Transparent LAN Services
Best Effort Ethernet Service
Ethernet/TDM Access to Frame Relay and/or ATM Service
Ethernet/TDM Access to IP Network
DMX as an Ethernet Hub using LNW70
DMX as an Ethernet Hub using LNW78
Ethernet Transport via RPR
SAN Distance Extensions with DMX
Converged Service Delivery via Metropolis
®
DSLAM Access
TransMUX Functionality with LNW18/20
Enhanced TransMUX Functionality with LNW20
Network Configurations
Path Switched Rings
2-Fiber BLSRs
Packet Rings
DWDM Optics
............................................................................................................................................................................................................................................................
C O N T E N T S i v
365-372-300
Issue 8.0 September 2006
Dual Node Ring Interworking
Single and Dual-Homing
Linear Optical Extensions
Hubbing
............................................................................................................................................................................................................................................................
Shelf Description
Circuit Packs
Circuit Pack Descriptions
Passive Optics Units (POUs)
External Optical Amplifiers
Power Specifications
DMX 20 Amp Shelf Power Specifications
............................................................................................................................................................................................................................................................
Physical Arrangements
Shelf Configurations
Shelf Configurations
Medium and Large Fabric Engineering Rules
Very Large Fabric (VLF) Engineering Rules
Network Bay Frames
Typical Bay Arrangement
Cabinet Arrangements
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
C O N T E N T S v
Environmental Considerations
Cross-connections
Cross-Connect Types
Allowable Cross-Connects
Assignment of VT Bandwidth on OC-48 and
OC-12 High-speed Interface
Synchronization
Network Synchronization Environment
Synchronization Features
Network Configurations
Timing Distribution
Synchronization Messaging
Sync Messaging Feature Details and Options
Sync Messaging Examples
Frequently Asked Network Timing Distribution Questions
............................................................................................................................................................................................................................................................
Maintenance
Three-tiered Operations
IAO LAN Ports (detail)
Operations Philosophy
Lucent Operations Interworking
Multi-Vendor Operations Interworking
Data Communications Channel (DCC)
Software Download (Generic)
Database Backup and Restore
Maintenance Signaling
Fault Detection, Isolation, and Reporting
Loopbacks and Tests
............................................................................................................................................................................................................................................................
C O N T E N T S v i
365-372-300
Issue 8.0 September 2006
Test Access
WaveStar
®
CIT
Introduction to the WaveStar
®
CIT
WaveStar
®
CIT Access
Protection Switching
Line Protection Switching
Path Protection Switching (Path Switched Rings)
Line Protection Switching (Line Switched Rings)
Spanning Tree
Resilient Packet Ring (RPR)
Link Aggregation (LNW70 LAN ports)
Equipment Protection
Performance Monitoring
Performance Monitoring Parameters
Performance Monitoring Data Storage
Performance Parameter Thresholds
TCA Transmission to OS
SNMP Parameters and Traps
Provisioning
Default Provisioning
Remote Provisioning
Cross-Connect Provisioning
Automatic Provisioning on Circuit Pack Replacement
Port State Provisioning
Channel State Provisioning
Line State Provisioning
Reports
Alarm and Status Reports
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
C O N T E N T S v i i
Performance Monitoring Reports
Maintenance History Reports
State Reports
Provisioning Reports
Version/Equipment List
Administration
Software Upgrades
IP Access for network management
Time and Date Synchronization
Office Alarms Interface
Remote NE Status
Network Size
Directory Services
Password Administration (CIT and System)
User-setable Miscellaneous Discrete Interface
............................................................................................................................................................................................................................................................
Engineering Drawings
Software and Documentation
Miscellaneous Equipment and Tools
............................................................................................................................................................................................................................................................
Worldwide Services
............................................................................................................................................................................................................................................................
C O N T E N T S v i i i
365-372-300
Issue 8.0 September 2006
............................................................................................................................................................................................................................................................
Lucent’s Quality Policy
Reliability Program and Specifications
Failure Rates
Sparing Information
Sparing Graph
International Standards Organization (ISO) Certification
............................................................................................................................................................................................................................................................
Electrical Interfaces
28DS1 (LNW6), 28DS1PM (LNW7), and 56 DS1/E1 (LNW8)
12DS3/EC1 (LNW16) and 48DS3/EC1 (LNW19/19B)
DS3 TransMUX (LNW18)
48DS3/EC1/TransMUX (LNW20)
10/100T (10/100 Mbps) Ethernet (LNW66 and LNW71)
100/1000BASE-TX (10/100 Mbps) Ethernet (LNW70)
10/100BASE-TX (10/100 Mbps) Ethernet (LNW74)
Electrical PTM 100/1000BASE-TX (100/1000 Mbps)
Ethernet (LNW63/64/70)
TDM Optical Interfaces
Quad OC-3 Low-speed OLIU (LNW36)
Quad OC-3 Low-speed OLIU (LNW37)
8-port OC-3 Low-speed OLIU (LNW45)
Dual OC-12 Low-speed OLIU (LNW46)
OC-12 High-speed OLIU (LNW48)
Quad OC-12 Low-speed OLIU (LNW49)
OC-12 High-speed OLIU (LNW50)
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
C O N T E N T S i x
OC-12 High-speed OLIU (LNW54)
OC-48 OLIU (DWDMs, LNW26B, LNW27, LNW28, LNW29,
LNW31, LNW32, LNW62, LNW76, and LNW77)
OC-192 OLIUs (LNW56, LNW57, LNW58, LNW59, LNW60,
LNW523, LNW527, LNW554, and LNW555)
SONET Optical Specifications: OC-3 and OC-12 Low-speed
OLIUs (LNW36, LNW46)
SONET Optical Specifications: OC-12 High-speed OLIUs
(LNW48, LNW50, and LNW54)
SONET Optical Specifications: OC-3 OLIUs (LNW37 and LNW45) with PTM pluggable optics
SONET Optical Specifications: OC-12 OLIUs (LNW49) with PTM pluggable optics
SONET Optical Specifications: OC-48 OLIUs (LNW26B, LNW27,
LNW28, LNW29, LNW32)
SONET Optical Specifications: OC-48 OLIU (LNW62)
SONET Optical Specifications: OC-48 OLIU
(LNW76 and LNW77)
OC-48 DWDM Optical Specification (LNW121B-LNW159B,
LNW221-LNW259, and LNW421-LNW459)
SONET Optical Specifications: OC-192 OLIU (LNW59)
SONET Optical Specifications: OC-192 OLIU
(LNW56 and LNW58)
SONET Optical Specifications: OC-192 OLIU
(LNW57 and LNW60)
DWDM OC-192 OLIUs (LNW523, LNW527, LNW554, and LNW555) Optical Specification
Lightguide Jumpers and Buildouts
Multimode Fiber Transmission with OC-3 and OC-12 circuit packs
Background Information
............................................................................................................................................................................................................................................................
C O N T E N T S x
365-372-300
Issue 8.0 September 2006
Ethernet/SAN Optical Specifications
4-port GbE PTM (1000BASE-TX and/or 1000BASE-SX/LX/ZX)
Private Line Optical Ethernet (LNW63)
8-port GbE PTM (1000BASE-TX and/or 1000BASE-SX/LX/ZX)
Private Line Optical Ethernet (LNW64)
Short-reach GbE (1000BASE-SX) Optical Ethernet (LNW67)
Long-reach GbE (1000BASE-LX) Optical Ethernet (LNW68)
GbE (1000BASE-X)/ Fast-E (100BASE-LX/TX)
Optical/Electrical Ethernet (LNW70)
FC-DATA: FICON/ESCON/Fibre-Channel (LNW73 and LNW73C)
SAN Transport Interface
10/100T (10/100BASE-T)/ Fast-E (100BASE-LX)
Electrical/Optical Ethernet Private Line (LNW74)
RPR Enabled GbE (1000BASE-X)/ Fast-E
(100BASE-LX/TX) Optical Ethernet (LNW78)
Allowed PTM Tranceivers
1000BASE-SX Optical Ethernet/SAN Specification
1000BASE-LX Optical Ethernet/SAN Specification
1000BASE-ZX Optical Ethernet/SAN Specification
100BASE-LX Optical Ethernet Specification
ESCON SAN Transport Specification (LNW73 and LNW73C)
System Performance
SONET Overhead Bytes
Signal Performance
Protection Switching
Transient Performance
Transmission Delay
Performance Monitoring
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
C O N T E N T S x i
Operations Interfaces
Craft Interface Terminal (PC-CIT)
Personal Computer Specifications for Software Download
LEDs, Indicators, and Office Alarms
Physical Specifications
Physical Specifications
Power Specifications
External Equipment Specifications
External Optical Amplifier
............................................................................................................................................................................................................................................................
Introduction to Ethernet Services
Ethernet/SAN Circuit Packs
Ethernet Transport
Tagging Modes
Quality of Service
Ethernet Service Management
Ethernet Service Configurations
SONET-Based Distance Extensions for
ESCON/FICON/Fibre-Channel Services
............................................................................................................................................................................................................................................................
C O N T E N T S x i i
365-372-300
Issue 8.0 September 2006
............................................................................................................................................................................................................................................................
Introduction to Performance Monitoring
OC-N Performance Parameters
EC-1 Performance Parameters
E1 Performance Parameters
STS-N Performance Parameters
VT1.5 Performance Parameters
VC-12 Performance Parameters
DS3 Performance Monitoring Parameters
DS1 Performance Monitoring Parameters
Ethernet/SAN Performance Monitoring Parameters
SNMP Parameters and Traps
............................................................................................................................................................................................................................................................
Area Address Assignment
Level 2 Router Assignment
IS-IS Level 2 Routing Remote Provisioning Sequence
IS-IS Level 2 Routing Provisioning Confirmation
Maximum Number of OSI Nodes
Engineering Rules and Guidelines
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
C O N T E N T S x i i i
............................................................................................................................................................................................................................................................
Shelf Description
Physical Requirements
Electrical Requirements and Objectives
Environmental Requirements and Objectives
Test Verification and Qualification
............................................................................................................................................................................................................................................................
GL Glossary
GL-1
............................................................................................................................................................................................................................................................
Index
............................................................................................................................................................................................................................................................
C O N T E N T S x i v
365-372-300
Issue 8.0 September 2006
List of Figures
............................................................................................................................................................................................................................................................
1-1 DMXplore providing enterprise access
1-2 Next-generation Loop Access with DMXtend
............................................................................................................................................................................................................................................................
3 Applications and Configurations
3-1 Multiservice Optical Access Network
3-3 Established Network Evolution
3-4 Voice and Private Line Access Application
3-6 Ethernet Private Line Transport Application
3-7 Multi-point Ethernet Private Line Application
3-8 Bandwidth Allocation within Ethernet circuit packs
3-9 Hitless Bandwidth Provisioning: 1st Span
3-10 Link aggregation at 100 Mbps (all ports in-service)
3-14 DMX providing Ethernet/TDM access to the Internet
3-16 Hybrid hub-and-spoke/RPR interconnect with LNW78
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
F I G U R E S x v
3-18 Basic vs. Enhanced Bridging
3-19 Steering Protection with Enhanced Bridging
3-20 Steering Protection with Basic Bridging
3-22 RPR Packet Ring interconnect via EOS VCG with LNW78
3-23 RPR Packet Ring interconnect via EOS VCG with LNW78
DMX Product Family SAN Transport
DMX Family Providing Converged Service
DMX Family Converged Service Application
3-32 Traffic Capacity in an OC-192 2-Fiber BLSR
3-33 Normal Traffic Flow in a 2-Fiber BLSR
3-34 Loopback Protection Switch in a 2-Fiber BLSR
3-36 Lucent Passive Optics Unit with DMX
3-37 External Optical Amplifier Application
3-38 Dual Ring Interworking Protection
3-40 Multinode OC-3/OC-12 Ring with OC-48 Ring Transport
3-41 Inter-function group hairpin
3-43 Linear Optical Extensions
............................................................................................................................................................................................................................................................
F I G U R E S x v i
365-372-300
Issue 8.0 September 2006
............................................................................................................................................................................................................................................................
4-2 DMX High Capacity Shelf Backplane Connectors
4-3 Passive Optics Unit (POU) Shelves (DWDM Filter Units):
4-5 MUX/DMUX Passive Optics Shelf
(16 Transmit at One End, 16 Receive at the Other End)
4-6 MUX/DMUX Passive Optics Shelf
(8 Transmit and 8 Receive at Each End)
4-7 Optical Amplifier (Front Access)
4-8 Optical Amplifier (Rear Access)
4-9 SYSCTL Circuit Pack (LNW2)
............................................................................................................................................................................................................................................................
5 System Planning and Engineering
5-1 DMX with large fabric Main circuit packs
5-2 DMX with medium fabric Main circuit packs
5-3 DMX with VLF Main circuit packs (LNW59)
5-4 Typical Bay Frame Arrangement Using High-capacity Shelf 5-21
5-6 Two-way add/drop, Unswitched, and 0x1Sn
5-7 Pass-through cross-connection on High-speed interface
5-8 Pass-through hairpin
5-9 SONET hairpinning
5-10 LNW20 portless mode cross-connects
5-11 Ethernet Multi-point cross-connection
5-14 Free Running/Line Timed Configuration - Ring Network
5-15 Tributary line timing references
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
F I G U R E S x v i i
5-16 External Timing/Line Timing - Ring Network
5-17 External Timing Configuration - Ring Network
5-18 DS1/E1 Timing Output and Plesiochronous
5-19 OC-n (OC-3/12/48/192) Derived DS1 Timing Reference
5-20 Timing from Multiplexed DS1
5-21 Synchronization Reconfiguration - Access Ring
5-22 External Timing with Derived DS1 Output, Part A and B
5-23 Automatic Synchronization Reconfiguration,Part A and B
5-24 Automatic Synchronization Reconfiguration,Part C and D
5-25 Automatic Synchronization Reconfiguration Part E and F
............................................................................................................................................................................................................................................................
6 Operations, Administration, Maintenance, and Provisioning
6-4 Remote Operations Philosophy
6-5 User/Network Side Designation on a UPSR/BLSR
6-6 User/Network Side Designation on an OC-3/12 UPSR with DDM-2000
6-7 User/Network Side Designation on a Low Speed OC-48 BLSR 6-24
CIT Access via rear IAO LAN Port
CIT Access via DCC
®
CIT Access via modem
6-13 Spanning Tree on LAN ports
6-14 Steering Protection with Enhanced Bridging
6-15 Steering Protection with Basic Bridging
6-16 Link aggregation at 100 Mbps (all ports in-service)
6-17 DS1/DS3 Line/Path Performance Monitoring
............................................................................................................................................................................................................................................................
F I G U R E S x v i i i
365-372-300
Issue 8.0 September 2006
6-18 DS1 Path Performance Monitoring
6-23 Operations Communication via IP over DCC
............................................................................................................................................................................................................................................................
9-1 Sparing Graph for a 10-Day Lead Time
............................................................................................................................................................................................................................................................
10-1 Transmission Over Multi-Mode Fiber
Connection Diagram using: Single-Mode Fiber
Offset-Launch Mode-Conditioning Patch Cord
............................................................................................................................................................................................................................................................
A-1 LNW63 Gigabit Ethernet (Private Line) Circuit Pack
A-2 LNW64 Gigabit Ethernet (Private Line) Circuit Pack
A-3 LNW73/73C Gigabit Ethernet (Private Line) Circuit Pack
A-4 LNW66 Fast Ethernet Circuit Pack
A-5 Gigabit Ethernet Circuit Pack
A-6 LNW70 In Private Line Mode
A-8 LNW71 Fast Ethernet (Private Line) Circuit Pack
A-9 LNW74 Fast Ethernet Hybrid (optical/electrical) Pack
A-10 LNW78 RPR Ethernet Interface
A-11 Ethernet Transport Through DMX
A-13 Virtual Concatenation Group
A-14 SONET Protected Cross-Connections
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
F I G U R E S x i x
A-15 Multi-point Cross-connections (unprotected)
A-16 Gigabit Multipoint Cross-Connections (Unprotected)
A-17 LNW63 and LNW70 Gigabit Multipoint
Cross-Connections (Unprotected)
A-18 LNW71 Multipoint Cross-Connections (Unprotected)
A-19 Ethernet-to-Ethernet Hairpin Cross-Connections
A-21 Ethernet Frame Format with Stacked VLAN Tags
A-24 Spanning Tree on LAN ports
A-25 Link aggregation at 100 Mbps (all ports in-service)
A-27 Local Flow Control of Ingress Traffic
A-28 Local Flow Control of Egress Traffic
A-29 End-to-End Flow Control (LNW66, LNW67, LNW68)
A-30 End-to-End Flow Control (LNW71/70/63)
A-31 End-to-End Flow Control (LNW74)
A-32 Queue and Buffer Architecture (LNW66, LNW67, LNW68) A-75
A-33 Buffer Architecture (LNW63/70/71/74)
A-34 802.1Q Mode VLAN Tag Processing
A-35 Transparent Mode Tag Processing
A-36 Transparent Mode Tag Processing with Stacked VLANs
A-37 Flow and Classifications of Traffic through
A-38 Ethernet Private Line Service over Protected UPSR
A-40 Spanning Tree Protected Private LAN and
A-41 Virtual Private Line with LNW70
............................................................................................................................................................................................................................................................
F I G U R E S x x
365-372-300
Issue 8.0 September 2006
A-43 RPR Packet Ring and Hairpin to Subtending Ring with LNW78A-120
A-44 Direction Reversal in UPSRs Joined via RPR and
Daisy Chained RPR Nodes within One NE
A-45 RPR Packet Ring interconnect via EOS VCG with LNW78
A-46 RPR Packet Ring interconnect via EOS VCG with LNW78
A-47 Remote LAN port aggregation/RPR interconnect
A-48 NE-local LAN port aggregation/interconnect
............................................................................................................................................................................................................................................................
C IS-IS Level 2 Routing Guidelines
C-1 Network with Level 2 Routers
C-4 Redundant Routes with the Level 2 Subdomain
C-5 Recommended Level 2 Router Assignments
Recommended Placement of Level 2 Routers
Recommended Navis™ Optical EMS Access via OSI LAN/WANC-20
Level 2 Router Assignments on an OSI LAN
............................................................................................................................................................................................................................................................
D Physical, Electrical, and Thermal Compatability Requirements for ODP Applications
D-1 DMX Shelf Side/Front View with Mounting Bracket
D-2 DMXtend Shelf Side/Front View with Mounting Bracket
D-3 DMXplore Wall-mount Shelf Side/Front View with
D-4 DMXplore Rack-mount Side/Front View with
D-5 Mounting Bracket Positions on DMX Shelf
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
F I G U R E S x x i
............................................................................................................................................................................................................................................................
F I G U R E S x x i i
365-372-300
Issue 8.0 September 2006
List of Tables
............................................................................................................................................................................................................................................................
............................................................................................................................................................................................................................................................
4-2 Circuit Packs in DMX Shelf
4-3 Main packs that allow portless LNW20 operation
4-4 DMX 30 Amp High Capacity Shelf Power
4-5 DMX 20 Amp High Capacity Shelf Power
4-6 High-capacity Shelf Current Drains
4-8 High-capacity Shelf Heat Dissipation
............................................................................................................................................................................................................................................................
5 System Planning and Engineering
5-1 Circuit packs with medium sized switch fabric
5-2 0x1 compatible combinations
5-3 Ethernet Circuit Pack Capacities Summary Part 1
5-4 Ethernet Circuit Pack Capacities Summary Part 2
5-5 Ethernet Circuit Pack Capacities for Ring Configuration
5-6 All Allowable UPSR Add-drop Cross-connections
5-7 All Allowable 1+1 Add-drop Cross-connections
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
T A B L E S x x i i i
5-8 All Allowable BLSR Add-drop Cross-connections
5-9 All Allowable Hairpin Cross-connections
5-10 Sync Messages with the S1 Byte
............................................................................................................................................................................................................................................................
6 Operations, Administration, Maintenance, and Provisioning
6-1 SYSCTL Faceplate Indicators and Functions
6-3 DMX OI Compatibility Summary
6-6 Remote Software Download Compatibility
6-9 Provisionable PM Parameters
6-10 DMX Time and Date Synchronization Compatibility
6-11 Remote NE Status Compatibility
6-12 Characters NOT Allowed in a WaveStar
CIT Password
6-13 Characters Allowed in a WaveStar
®
CIT Password
6-14 Characters NOT Allowed in a DMX Password and User ID 6-128
6-15 Characters Allowed in a DMX Password and User ID
............................................................................................................................................................................................................................................................
7-3 Lightguide Build-outs and Accessories
7-4 PTM Optics for LNW37/45/49/59/62/63/64/70/73/73C/74/78 7-9
............................................................................................................................................................................................................................................................
T A B L E S x x i v
365-372-300
Issue 8.0 September 2006
............................................................................................................................................................................................................................................................
10-1 Transmission Interface Standards
10-5 SONET Optical System Specifications
10-6 SONET Optical Transmitter Information
10-7 SONET Optical Receiver Information
10-8 SONET Optical Specifications and Link Budgets
10-9 SONET Optical System Specifications
10-10 SONET Optical Transmitter Information
10-11 SONET Optical Receiver Information
10-12 SONET Optical Specifications and Link Budgets
10-13 SONET Optical System Specifications
10-14 SONET Optical Transmitter Information
10-15 SONET Optical Receiver Information
10-16 SONET Optical Specifications and Link Budgets
10-17 SONET Optical System Specifications
10-18 SONET Optical Transmitter Information
10-19 SONET Optical Receiver Information
10-20 SONET Optical Specifications and Link Budgets
10-21 SONET Optical System Specifications
10-22 SONET Optical Transmitter Information
10-23 SONET Optical Receiver Information
10-24 SONET Optical Specifications and Link Budgets
10-26 SONET Optical System Specifications
10-27 SONET Optical Transmitter Information
10-28 SONET Optical Receiver Information
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
T A B L E S x x v
10-29 SONET Optical Specifications and Link Budgets
10-30 SONET Optical System Specifications
10-31 SONET Optical Transmitter Information
10-32 SONET Optical Receiver Information
10-33 SONET Optical Specifications and Link Budgets
10-34 SONET Optical System Specifications
10-35 SONET Optical Transmitter Information
10-36 SONET Optical Receiver Information
10-37 Optical Specifications and Link Budgets
10-38 SONET Optical System Specifications
10-39 SONET Optical Transmitter Information
10-40 SONET Optical Receiver Information
10-41 OC-48 DWDM OLIUs Wavelength Plan
10-42 Optical Requirements and Link Budgets for the
10-44 SONET Optical System Specifications
10-45 SONET Optical Transmitter Information
10-46 SONET Optical Receiver Information
10-47 Optical Specifications and Link Budgets
10-48 SONET Optical System Specifications
10-49 SONET Optical Transmitter Information
10-50 SONET Optical Receiver Information
10-51 Optical Specifications and Link Budgets
10-52 SONET Optical System Specifications
10-53 SONET Optical Transmitter Information
10-54 SONET Optical Receiver Information
10-55 Optical Specifications and Link Budgets
10-56 SONET Optical System Specifications
10-57 SONET Optical Transmitter Information 10-87
10-58 SONET Optical Receiver Information 10-87
10-59 OC-192 DWDM OLIUs Wavelength Plan
............................................................................................................................................................................................................................................................
T A B L E S x x v i
365-372-300
Issue 8.0 September 2006
10-60 Optical Specifications and Link Budgets
10-61 PTM Optics for LNW63/64/70/73/73C/74/78
10-62 1000BASE-SX Operating Range Over Each
10-63 1000BASE-SX Transmit Specifications
10-64 1000BASE-SX Receive Specifications
10-65 1000BASE-SX Link Budgets and Penalties
10-66 1000BASE-LX Operating Range
10-67 1000BASE-LX Transmit Specifications
10-68 1000BASE-LX Receive Specifications
10-69 1000BASE-LX Link Budgets and Penalties
10-70 1000BASE-ZX Operating Range
10-71 1000BASE-ZX Transmit Specifications
10-72 1000BASE-ZX Receive Specifications
10-73 1000BASE-ZX Link Budgets and Penalties
10-74 100BASE-LX Operating Range Single-Mode Fiber
10-75 100BASE-LX Transmit Specifications
10-76 100BASE-LX Receive Specifications
10-77 100BASE-LX Link Budgets and Penalties
10-78 ESCON Optics Operating Range Multi-Mode Fiber
10-79 ESCON Transmit Specifications
10-80 ESCON Receive Specifications
10-82 Transmission Delay in Microseconds
10-83 DMX 30 Amp High Capacity Shelf Power
10-84 DMX 20 Amp High Capacity Shelf Power
10-85 High-capacity Shelf Current Drains
10-87 High-capacity Shelf Heat Dissipation
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
T A B L E S x x v i i
............................................................................................................................................................................................................................................................
A-1 1way Cross-Connection Support
A-2 Allowed Traffic Management Modes per Port Type
A-3 Handling of Untagged or Unprovisioned service at
A-4 Default mapping of User Priority to CoS
A-4 Default mapping of DSCP to CoS
A-5 Combination of VLAN Tagging and
A-6 Ethernet Private Line Services
A-7 Ethernet Packet Ring Services
A-8 VCGs Available on Ethernet Circuit Packs
A-9 Supported Ethernet Services
A-10 Typical Ethernet Service Configurations
............................................................................................................................................................................................................................................................
B-2 SONET OC-N Performance Parameters
B-3 SONET EC-1 Performance Parameters
B-4 SONET E1 Performance Parameters
B-5 SONET STS-N Performance Parameters
B-6 SONET VT1.5 Performance Parameters
B-7 SONET VC-12 Performance Parameters
B-8 DS3 Performance Parameters
B-9 DS3 Signal formats, PM signal formats, and VM modes
B-10 DS1 Performance Parameters
B-11 CV-PFE parameter increments
B-12 Ethernet Performance Parameters
............................................................................................................................................................................................................................................................
T A B L E S x x v i i i
365-372-300
Issue 8.0 September 2006
............................................................................................................................................................................................................................................................
C IS-IS Level 2 Routing Guidelines
............................................................................................................................................................................................................................................................
D Physical, Electrical, and Thermal Compatability Requirements for OSP Applications
Dimensions and Weight
D-2 DMX Shelf Power Supply Requirements
D-3 DMX 20 Amp High Capacity Shelf Power
D-5 DMX Power Supply Requirements
D-6 DMXtend Shelf Current Drains
D-7 DMXplore Power Supply Requirements
D-8 DMXplore Shelf Current Drains
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
T A B L E S x x i x
............................................................................................................................................................................................................................................................
T A B L E S x x x
365-372-300
Issue 8.0 September 2006
About this information product
Purpose
This applications and planning guide (APG) provides the following information for the Metropolis
®
DMX Access Multiplexer:
• Features
• Applications
• Operation
• Engineering
• Support
• Specifications
• Ordering
Reason for reissue
Issue 8.0 of this document details features associated with Release 7.0 of DMX. Release 7.0 includes software enhancements and introduces new hardware to support the R7.0 features detailed herein.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006 x x v
Safety labels
This document may contain safety labels in the form of
DANGERS
,
WARNINGS
, and
CAUTIONS
.
These admonishments have the following definitions:
•
DANGER
shows the presence of a hazard that will cause death or severe personal injury if the hazard is not avoided.
•
WARNING
shows the presence of a hazard that can cause death or severe personal injury if the hazard is not avoided.
•
CAUTION
shows the presence of a hazard that will or can cause minor personal injury or property damage if the hazard is not avoided. Caution is also used for property-damage-only accidents.
This includes equipment damage, loss of software, or service interruption.
The alert symbol appears throughout this document to alert the user to these safety labels.
Intended audience
This applications and planning guide is intended for network planners and engineers. However, it is also for anyone who needs specific information regarding the features, applications, operation, engineering, and ordering of the DMX Access Multiplexer.
How to use this information product
The following is a brief description of the contents of each chapter in this document:
•
“About This Document”
describes the purpose, intended audience, reason for reissue, and organization of this document. This section references related documentation and explains how to order, make comments, or recommend changes to this document.
• Chapter 1,
“System Overview,”
describes the DMX Access
Multiplexer. This introductory section also lists the features included in the releases covered by this document.
• Chapter 2,
“Features,”
briefly describes the features listed in
Chapter 1. These features are described in more detail in Chapter
3, “Network Topologies,” Chapter 4, “Product Description,” and
Chapter 6, “Operations, Administration, Maintenance, and
Provisioning.”
• Chapter 3,
“Applications and Configurations,”
describes how the
DMX Access Multiplexer shelf serves diverse needs such as embedded network evolution, access transport for voice and private line services, interoffice transport, broadband business data access, DSLAM access, IP network infrastructure, enterprise
............................................................................................................................................................................................................................................................
x x v i
365-372-300
Issue 8.0 September 2006
LAN interconnect and transport, ISP carrier access, and cable access to internet applications through configurations such as path switched ring, linear optical extensions, homing, and hubbing.
• Chapter 4,
“Product Description,”
describes the DMX Access
Multiplexer hardware, including the shelf, circuit packs, cables, and power.
• Chapter 5,
“System Planning and Engineering,”
summarizes physical arrangement, cross-connection, and synchronization information to help you plan procurement and deployment of the
DMX Access Multiplexer.
• Chapter 6,
“Operations, Administration, Maintenance, and
Provisioning,”
defines the “maintenance philosophy,” outlining the various features available to monitor and maintain the DMX
Access Multiplexer.
• Chapter 7,
“Ordering,”
provides equipment ordering information for the DMX Access Multiplexer.
• Chapter 8,
“Product Support,”
describes how Lucent Technologies supports the DMX Access Multiplexer. This chapter includes information about engineering and installation services, technical support, documentation support, and training available from
Lucent Technologies.
• Chapter 9,
“Reliability and Quality,”
provides the Lucent
Technologies quality policy and describes the reliability program.
• Chapter 10,
“Technical Specifications,”
lists the technical specifications for the Metropolis
®
DMX Access Multiplexer.
• Appendix A,
“Ethernet/SAN,”
details all Ethernet/SAN specific equipment and specifications relevant to the Metropolis
®
DMX
Access Multiplexer.
• Appendix B,
“Performance Monitoring,”
primarily lists the performance monitoring parameters for the Metropolis
®
DMX
Access Multiplexer.
• Appendix C,
“IS-IS Level 2 Routing Guidelines,”
provides guidelines for L2 routing on the Metropolis
®
DMX Access
Multiplexer.
• Appendix D,
“Physical, Electrical, and Thermal Compatibility
Requirements for OSP Applications”
provides guidelines for the installation of the DMX, DMXtend, and DMXplore in OSP cabinet applications.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006 x x v i i
• Glossary provides definitions for telecommunication acronyms and terms.
• Index supplies users with specific subjects and corresponding page numbers to find necessary information.
Conventions used
Bold
typeface signifies emphasis.
Italic typeface denotes a particular product line or information product.
Bold Courier
typeface signifies a command.
For the remainder of this information product, “DMX” is used in place of Metropolis
®
DMX Access Multiplexer in most cases.
Electronic documentation
Documentation for the DMX Access Multiplexer is now available in electronic form, on compact disk read only memory (CD-ROM). CD-
ROM has many advantages over traditional paper documentation, including cost savings and search and retrieve capability.
Ordering information
CD-ROM documentation is available by annual subscription (on standing order). To order, call your Technical Information Resource
Manager, your Lucent Technologies Account Executive, or the Lucent
Technologies Customer Information Center (
1-888-582-3688
).
Pricing information
For pricing information or a list of all documents that are available on
CD-ROM, contact your Lucent Technologies Network Systems
Account Executive or the Lucent Technologies Customer Education and Training hotline (
1-800-334-0404
).
Technical information
For technical information, call Lucent Technologies Documentation
Support (
1-888-LTINFO6
).
How to comment Fax
Fax comments to
(407) 767-2760
.
Phone
You may also report errors or request changes to this document by calling the toll-free number,
1-888-LTINFO6 (1-888-584-6366)
. When calling, be sure to have the nine-digit document number ready.
............................................................................................................................................................................................................................................................
x x v i i i
365-372-300
Issue 8.0 September 2006
Comments may be sent via email to
.
World Wide Web
Comments may also be sent by filling out a web-based form at
www.lucent-info.com
.
How to order
To order additional copies of this document or to request placement on the standing order list, refer to the information below.
Commercial customers
A check, money order, purchase order number, or charge card number is required with all orders. Make checks payable to Lucent
Technologies. Lucent Technologies entities should use Form 1-80.80
FA, available through the Customer Information Center (CIC). RBOC/
BOC customers should process orders through your Company
Documentation Coordinator.
Internet orders
Hardware, software, and documentation may be ordered on the world wide web. For more information, visit Lucent on the web at
www.lucentdocs.com
.
From Canada: email orders to [email protected].
Mail orders
To order documentation by mail, send correspondence to the address below:
Lucent Technologies
Customer Information Center
Attention: Order Entry Section
2855 North Franklin Road
P.O. Box 19901
Indianapolis, IN 46219
Telephone orders
Within US: 1-888-LUCENT-8 (1-888-582-3688)
From Caribbean, Latin America, and Canada: (Toll) 1-317-322-6616
From Europe, Middle East, and Africa: (Toll) 1-317-322-6416
From Asia/Pacific Region, China, Australia, and New Zealand:
(Toll) 1-317-322-6411
FAX orders
Within US (24 hrs/day, toll free): 1-800-566-9568
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006 x x i x
International: 1-317-322-6699
............................................................................................................................................................................................................................................................
x x x
365-372-300
Issue 8.0 September 2006
1 System Overview
Overview
............................................................................................................................................................................................................................................................
Purpose
This chapter introduces the Metropolis
®
DMX Access Multiplexer system.
Contents
The following topics are included in this chapter:
Introduction to the DMX Access Multiplexer
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 - 1
System Overview
Overview of the Metropolis
®
Portfolio
............................................................................................................................................................................................................................................................
Purpose
Metropolitan, "metro," networks are the communications networks that link homes and businesses to larger, long-distance core networks.
These networks are complex because they are filled with both old and new networking equipment and must carry all types of service traffic, including voice, data and video.
Driven by the exponential growth of the Internet, requirements for metropolitan optical transport networks are changing quickly from pure circuit networks to hybrid networks. This evolution requires metro access networks to aggregate the local loop or last-mile bandwidth in order to integrate with the high-speed core/backbone networks. These requirements are driving metropolitan network evolution from traditional SONET multiplexers into more flexible, higher-speed, dataaware platforms—a necessity for optical edge solutions.
Solution
Lucent Technologies is helping service providers to cost-effectively deploy solutions that can accommodate a multitude of services, such as voice, private line, Ethernet, IP, frame relay, and ATM. The Metropolis
®
portfolio offers a seamless evolution to next-generation metro solutions that can eliminate the bottleneck in the metropolitan network, allowing service providers to deliver new high-speed, revenue-generating services such as gigabit Ethernet, virtual private networks (VPN), storage area networks and digital subscriber lines (DSL).
...........................................................................................................................................................................................................................................................
1 - 2
365-372-300
Issue 8.0, September 2006
Overview of the Metropolis® Portfolio
System Overview
Portfolio
Lucent designed its Metropolis
®
portfolio so customers can choose the solution that best accommodates their existing networks, allowing them to bring new services to market quickly and cost effectively.
Metropolis
®
includes two categories of next-generation products based on the most common types of metro networks:
• Next-Generation SONET—Metropolis DMX, DMXtend,
DMXpress, and DMXplore Access Multiplexers— which leverages existing optical equipment while providing a solid foundation for future bandwidth, gigabit Ethernet (GbE) and IP services growth.
• MetroWDM—Metropolis EON (Enhanced Optical Networking),
Lambda Unite, and Metropolis WSM, metro core DWDM solutions for regional traffic.
Each of the Metropolis
®
solutions can fuse with Lucent’s new multiservice data switches and existing IP and ATM equipment to provide an end-to-end broadband network that links to long-distance or other metro networks.
Low Cost Access
Metropolis
®
DMX
tend
Metropolis
®
DMX
plore
Metropolis
®
DMX
plore
SONET/SDH Metropolitan Access/
DSLAM Access Transport
(Stinger)
Globe Aggregation and Transport
(Optical Edge Service)
Multiservice TDM
Bulk Carrier/to carrier
Interconnect
(Wavelength Service)
Digital Video Services
(WaveStar
®
DVS)
Metropolis
®
DMX/ADM
TDM to IP Services Migration
High Margin Ethernet Services
High Security Multiservices
Access (PSAX, Stinger,
GX SSQ, Springtide)
Low Cost Last Mile Aggregation
Scaleability from 2.5G to
10G to 40G and Beyond
GX 550
WaveStar
®
TDM 2.5G/10G
Metro EON
(40G/80G)
Lambda Unite
Metropolis WSM
WaveStar
®
OLS 1.6T
Metropolitan Core
WaveStar
®
OLS 1.6T
WaveStar
®
OLS 1.6T
Multiservice
Edge Node
Optical Core - Long Haul
®
2.5G = WaveStar TDM 2.5G (OC-48) 2F
®
10G = WaveStar TDM 10G (OC-192) 2F
®
DMX = Metropolis DMX Access Multiplexer
DMX
tend
®
= Metropolis DMX
tend
Access Multiplexer
DMX
plore
= Metropolis DMX plore Access Multiplexer
®
ADM = Metropolis ADD/Drop Multiplexer nc-dmx-111
®
WSM= Metropolis WaveLength Services Manager
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 - 3
System Overview
Metropolis
®
Metro Access Solutions
............................................................................................................................................................................................................................................................
Overview
This section provides a brief description of each of the following products which comprise the Metropolis portfolio:
• Metropolis
®
DMXplore Access Multiplexer
• Metropolis
®
DMXtend Access Multiplexer
• Metropolis
®
DMX Access Multiplexer
...........................................................................................................................................................................................................................................................
1 - 4
365-372-300
Issue 8.0, September 2006
System Overview
Metropolis
®
DMXplore Access Multiplexer
............................................................................................................................................................................................................................................................
Overview
DMXplore is ideal for Fiber-to-the-Business (FTTB) and end-user access applications. It has been designed with an extremely small footprint to enable seamless integration as a piece of customer premise equipment (CPE). Supporting OC-3/12 high-speed, DS1/DS3, and 10/
100 Mbps Ethernet tributary interfaces, DMXplore is an ideal nextgeneration CPE for its ability to provide voice and data devices to a variable number of end-users.
DMXplore is designed with a modular architecture to support protected or unprotected DS1 and DS3 transport applications using OC-3/12 high-speed interfaces. This modular architecture supports separate working and protection circuit packs, thus allowing the continuation of service in the event of failures.
DMXplore features combo cards supporting OC-3/12 high-speed interfaces as well as the switch fabric servicing the DS1/DS3 ports.
The DMXplore is optimized for low-cost, small footprint entry into end-user environments. The DMXplore can be placed in an office building, medical facility, hotel, college dormitory, or any building housing a moderate amount of multiple end users. In its ability to provide a flexible mix of DS1, DS3, and 10/100 Mbps interfaces, the
DMXplore is ideal as a collection point for multiple lines within a diverse MTU (Multi-Tenant Unit), providing a variety of both voice and data services.
Figure 1-1 DMXplore providing enterprise access
DMX
plore
- DS1/-3 provides:
- 10/100 Mbp Ethernet
DMX
plore
DMX
plore
Metropolis
®
DMX
tend
OC-12
Metropolis
DMX
®
UPSR
Metropolis
®
DMX
tend
OC-3 UPSR/1+1
DMX
plore
OC-3
UPSR
DMX
plore
Metropolis
®
DMX
Metropolis
®
DMX
press
OC-48/192 UPSR
Metropolis
®
DMX
Metro Core
DMX = Metropolis
®
DMX Access Multiplexer
DMX
tend
= Metropolis
®
DMX
tend
Access Multiplexer
DMX
plore
= Metropolis
®
DMX
plore
Access Multiplexer
MA-DMXplore-11
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 - 5
System Overview
Metropolis
®
DMXtend Access Multiplexer
............................................................................................................................................................................................................................................................
Introduction to DMXtend
The DMXtend Access Multiplexer is a single-shelf network multiplexer designed primarily for access transport, business access, and regional interoffice applications transporting voice, data, and SAN traffic at the OC-3/12/48/192 level via 1+1, or unidirectional path switched ring (UPSR) protected lines.
DMXtend supports a wide array of wideband and broadband transport, including traditional SONET transport of DS1, E1, DS3, EC-1,
TransMUX, OC-3, OC-12, OC-48, OC-192 as well as 10/100/1000
Mbps LAN, Resilient Packet Ring (RPR), and FICON/ESCON/Fibre-
Channel SAN transport. The shelf can be equipped to serve many diverse network applications and supports a variety of operations interfaces for current and evolving network operations needs.
The figure below shows the DMXtend providing loop access for the various interfaces listed above, and interworking with DDM and
FT-2000 to enable a network transition to next-generation, higher capacity services, and shows how the DMXtend can interwork with embedded, legacy equipment.
Figure 1-2 Next-generation Loop Access with DMXtend
Access Loop
DS1/3
10/100/1000
MbPS
Metropolis
®
DMX tend
Metropolis
®
DMX tend
DS1/3
Fiber
Reach
DS1/3
Metropolis
®
DMX tend
For TR-008 DLC
DS1/3
10/100/1000
MbPS
Metropolis
®
DMX tend
DDM
DDM
DDM
OC-48
OC-3
OC-3
Central
Office
DS1s
DCS
STS-1
OC-3
Sx:x
LNW67
1G SX
LUCENT
BRK A 20A
ON
LNW26
OC-48 Sx:x 1310 LR
LUCENT
LNW1
SYSCTL Sx:x
LUCENT
BRK B 20A
ON
177D
BLANK Sx:x
LUCENT
LNW26
OC-48 Sx:x 1310 LR
LUCENT
LNW36
OC-3 Sx:x
LUCENT
LNW36
OC-3 Sx:x
LUCENT
Sx:x
LNW46
LUCENT
OC-12 1310LR
Sx:x
LNW46
LUCENT
OC-12 1310LR
LNW6
28DS1 Sx:x
LUCENT
LNW6
28DS1 Sx:x
LUCENT
LNW16
12DS3/EC1 Sx:x
LUCENT
LNW16
12DS3/EC1 Sx:x
LUCENT
FAULT
ACTIVE
28DS1
FAULT
ACTIVE
28DS1
FAULT
ACTIVE
FAULT
ACTIVE
12DS3/
EC1
12DS3/
EC1
1G SX
FAULT
ACTIVE
OUT IN
1
2
FAULT
ACTIVE
OC-48
OLIU
OUT IN
SEL
UPD/
INT
LAN
CIT
RS
232
FAULT
CR
MJ
MN
ABN
FE
NE
ACO
ACO
TEST
IND
177D
BLANK
FAULT
ACTIVE
OC-48
OLIU
OUT IN
FAULT
ACTIVE
OC-3
OLIU
FAULT
ACTIVE
OC-3
OLIU
OUT IN OUT IN
FAULT
ACTIVE
OC-12
OLIU
FAULT
ACTIVE
OC-12
OLIU
1 1 OUT IN OUT IN
2
3
2
3
1 1
2 2
4 4
A1 A2 B1 B2 G1 M1 CTL G2 M2
DMX
C1 C2 D1 D2
DS3,OC-3
For TR-303 DLC
FR/ATM
Edge
Class 5
Switch
"5ESS"
Switch (es)
OC-12
DDM
DS1/3
10/100 MbPS
OC-3
Metropolis
DMX tend
®
DMX = Metropolis
®
DMX Access Multiplexer
DMX tend
®
= Metropolis DMX tend Access Multiplexer
DDM
NC-DMXtend-002
...........................................................................................................................................................................................................................................................
1 - 6
365-372-300
Issue 8.0, September 2006
System Overview
Introduction to the DMX Access Multiplexer
............................................................................................................................................................................................................................................................
Overview
The DMX Access Multiplexer is a single-shelf network multiplexer designed primarily for access transport, business access, and regional interoffice applications transporting voice and data at the
OC-12/OC-48/OC-192 level via a UPSR, BLSR, or 1+1 linear optical extension.
Lucent’s rich history of SONET multiplexers provides the foundation for the DMX. The DMX builds on that tradition by providing the tools necessary for the new generation of access networks: greater capacity, increased network flexibility, diverse functionality, and reliable service.
DMX, a SONET line terminating network element, supports a wide array of wideband and broadband transport, including traditional
SONET transport of DS1, E1, DS3, EC-1, TransMUX, OC-3, OC-12,
OC-48, and OC-192 signals, as well as 10/100/1000 Mbps LAN,
Resilient Packet Ring (RPR) and FICON/ESCON/Fibre-channel SAN transport. The shelf can be equipped to serve many diverse network applications and supports a variety of operations interfaces for current and evolving network operations needs.
Functionality
There are 13 circuit pack slots in each shelf, consisting of the following:
• 1 Control slot (CTL) for the SYSCTL (LNW1 or LNW2)
• 2 Main slots (M1, M2) for high-speed optical line interface units
(OC-12, OC-48, or OC-192) or the Main Switch Pack (LNW80)
• 8 multipurpose Function Unit slots (A through D) for DS1, DS3,
E1, TransMUX, EC-1, OC-3, OC-12, OC-48, 10/100BASE-TX/
LX and 10/100BASE-TX/LX Private Line, 1000BASE-SX,
1000BASE-LX, RPR, ESCON, FICON, and Fibre-Channel service
• 2 Growth slots (G1, G2) for OC-3, OC-12, OC-48,
1000BASE-X SX/LX, optical 100BASE-LX, RPR, ESCON,
FICON, and Fibre-Channel service. In R7.0, Growth slots can also host the LNW20 TransMUX card in portless DS3 mode.
The Growth slots are regarded as Function Unit slots in Release
7.0, but in the future may also be used for additional features.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 - 7
Introduction to the DMX Access Multiplexer
System Overview
Release 7.0 supports the following circuit packs:
• System Controller (LNW2)
• 28DS1 (LNW6)
• 28DS1PM (LNW7)
• 56DS1/E1 (LNW8)
• 12-port DS3 TransMUX (LNW18)
• 48TMUXDS3EC1 (LNW20)
• 12DS3/EC1 (LNW16)
• 48DS3/EC1 (LNW19)
• 48DS3/EC1 with terminal loopbacks (LNW19B)
• Quad OC-3 OLIU (LNW36)
• Eight-port OC-3 PTM OLIU (LNW45)
• Quad OC-3 PTM OLIU (LNW37)
• Dual OC-12 OLIU (LNW46)
• OC-12 OLIU (LNW48)
• Quad OC-12 PTM OLIU (LNW49)
• OC-12 OLIU (LNW50)
• OC-12 OLIU (LNW54)
• Quad OC-48 PTM OLIU (LNW62)
• OC-48 OLIU (LNW26B)
• OC-48 OLIU (LNW27)
• OC-48 OLIU (LNW28)
• OC-48 OLIU (LNW29)
• OC-48 OLIU (LNW76)
• OC-48 OLIU (LNW77)
• OC-48 OLIU (LNW31)
• OC-48 OLIU (LNW32)
• OC-48 DWDM OLIUs (LNW421-459, LNW221-259, and
LNW121B-159B) (32 wavelengths for both network and tributary interfaces)
• OC-192 OLIU (LNW56)
• OC-192 OLIU with Tone Circuitry (LNW57)
...........................................................................................................................................................................................................................................................
1 - 8
365-372-300
Issue 8.0, September 2006
Introduction to the DMX Access Multiplexer
System Overview
• OC-192 OLIU with Tone Circuitry and on-board amplifier
(LNW60)
• OC-192 OLIU (LNW58)
• Dual OC-192 OLIU (LNW59)
• OC-192 OLIU (LNW523— DWDM, 4-color tunable)
• OC-192 OLIU (LNW527— DWDM, 4-color tunable)
• OC-192 OLIU (LNW554— DWDM, 4-color tunable)
• OC-192 OLIU (LNW555)
• 1G SX/LX Private Line (4— 1000BASE-LX/SX ports) (LNW63)
• Octal 1GbE Private Line (8 —1000BASE-SX/LX/ZX optical and/ or electrical 1000BASE-TX) (LNW64)
• 10/100Mbps (24 100BASE-TX ports) (LNW66)
• 1G SX (2— 1000BASE-SX ports) (LNW67)
• 1G LX (2— 1000BASE-LX ports) (LNW68)
• 100/1000 Mbps (4— 100BASE-LX and
4— 1000 BASE-X ports) (LNW70)
• 10/100Mbps Private Line (24— 100BASE-TX ports) (LNW71)
• SAN circuit pack (FC-DATA) with choice of FICON/ESCON/
Fibre-channel interfaces using PTM optics (LNW73)
• SAN circuit pack with compression, choice of FICON/ESCON/
Fibre-channel interfaces using PTM optics (LNW73C)
• 10/100Mbps Private Line (8— 100BASE-X and
16 100BASE-TX ports) (LNW74)
• 10/100Mbps RPR (4— 100BASE-X and 2 1000BASE-X ports)
(LNW78)
• Electric Continuity Test Tool (for DS1/DS3/Ethernet Cabling)
(LNW94 and LNW93)
• Main Switch Pack— no optics (LNW80)
Important!
DS1, DS3, EC-1, E1, TransMUX, and 10/100-TX functionality is not supported in the Growth slots. 100 BASE-LX
(optical Fast Ethernet) functionality is supported in Growth Slots.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 - 9
Introduction to the DMX Access Multiplexer
System Overview
Interface Density
DMX provides a VT1.5 and STS-1 cross-connect fabric. DMX’s main switch fabric is contained in each of the high-speed (network-side interface) circuit packs, located in the MAIN slots. The MAIN slots house OC-12, OC-48, and OC-192 high-speed interfaces. They can also house the LNW80 switch pack. The LNW59 VLF Main enables
0x1 Fn/Growth slot equipage beginning in R7.0. In many cases, this doubles the overall capacity of the shelf.
The table below details the maximum number of signals that DMX can transport if all Function Unit (and Growth Slots where applicable) groups are equipped with a particular circuit pack (for example, 80
1000BASE-SX/LX/ZX ports if both slots in all four Function Unit and
Growth groups are equipped with the LNW64 circuit packs (this 0x1 configuration requires VLF Main packs).
Table 1-1 Interface Densities
Interface Type
DS1/E1
DS3/EC-1
TransMUX
OC-3
OC-12
OC-48
OC-192
100BASE-TX
100BASE-LX (optical)
1000BASE-SX/LX/ZX
1000BASE-TX
FICON/ESCON/
Fibre-Channel
96
80
80
80
40
192
80
40
40
Capacity/Main Switch
VLF
(0x1 equipped)
Large/
Medium
Fabric
224
192
224
192
4
192
80
40
10
2
Comments
Electrical TDM packs, and other packs that require rear access, do not support true 0x1, hence, overall capacity does not increase with VLF Mains
192 capacity requires the 48 port LNW20
80 unprotected, 40 protected
40 unprotected, 20 protected
40 capacity requires LNW62, only supported on VLF equipped shelves. 40/10 unprotected, 20/5 protected
4 capacity requires LNW59. LNW59 provides 2 OC-192 ports. 4 unprotected with LNW59 only, 2/1 protected
96
40
20
20
20
Larger capacities associated with VLF Mains require 0x1 equipage in all slots, only supported in R7.0 and later releases.
...........................................................................................................................................................................................................................................................
1 - 1 0
365-372-300
Issue 8.0, September 2006
Introduction to the DMX Access Multiplexer
System Overview
DMX also provides STS-1 virtual concatenation. STS-1 VCAT increases flexibility when managing Ethernet services. Each
10/100BASE-TX/PL and 1000BASE-SX/LX/ZX Ethernet service can be provisioned to any number of STS-1s (up to 21 STS-1s per VCG).
This is true for all Ethernet packs except LNW71. The LNW71 and
LNW74 can accept 1 or 2 STS-1s or a single STS-3c per port (the
LNW74 also supports VT1.5 VCAT). The LNW73/73C provides STS-
1 and STS-3c virtual concatenation.
Shelf size
The High-Capacity shelf has the following characteristics (includes integral fan unit):
• Width: 17.6 inches
• Height: 19 inches (includes integral fan unit)
• Depth (front to back): 13.75 inches (all optical applications only: without back cover and interface connectors*)
• Weight (with circuit packs): 57 pounds
• Weight (without circuit packs): 38 pounds
Important!
*: 15 inches with interface connectors, 16 inches with connectors and cover.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 - 1 1
Introduction to the DMX Access Multiplexer
System Overview
Operations
The DMX is representative of ten years of Lucent’s innovation and experience in network operations, control, and maintenance. Utilizing
Level 1 and Level 2 Target Identifier (TID) Address Resolution
Protocol (TARP), a consistent and standard form of address resolution is in place, enabling the DMX network to be easily monitored and maintained.
DMX also supports standard interworking using the Open Systems
Interconnection (OSI) seven-layer protocol stack or IP over the DCC.
The OSI seven-layer protocol stack refers to the OSI reference model, a logical framework for network operations standardized by the ISO.
This provides for large networks up to 1000 NEs via level 1 area provisioning and level 2 routing.
The DMX is designed for easy installation and operation. Centralized operation is supported by a full set of single-ended operations (SEO), control, and maintenance features. Integrated test capabilities and default provisioning simplifies installation.
Basic maintenance tasks can be performed using faceplate LED displays and controls, while a craft interface terminal (CIT) or a remote
OS gives access to sophisticated maintenance, provisioning, and reporting features.
Built-in maintenance capabilities support both installation and system operation. A DMX can be tested and installed without external test equipment.
...........................................................................................................................................................................................................................................................
1 - 1 2
365-372-300
Issue 8.0, September 2006
System Overview
Feature Release Plan
............................................................................................................................................................................................................................................................
Overview
This section outlines the major features of Releases 7.0. The feature release plan will be updated for each future release of the system.
A list of important features from past releases can be found directly following the R7.0 Features.
Release 7.0 Features
Listed below are the Release 7.0 features.
•
Dual OC-192 VLF optical interface (LNW59)
Dual OC-192 Very Large Fabric (VLF) Mains (LNW59) support
OC-192 add/drop, UPSR, and BLSR configurations, single- and dual-homing, revertive or non-revertive linear 1+1 protection switching. The LNW59 provides 2 XFP ports capable of supporting 1.3SR1, 1.5IR2, and 1.5LR2 XFPs. It can also function as a headless main, similar to the LNW80 (i.e. with no optics).
For overall capacity, the LNW59 boasts a 20G optical main with a
240G centralized STS switch fabric, 30G centralized VT termination capacity, and 40G VT switch fabric. When DMX is equipped with the LNW59 VLF Main, all switching takes place on the LNW59. The switch fabrics on the low-speed, tributary optical circuit packs are disabled. The LNW59 further upgrades the shelf’s overall capacity by enabling the Function and Growth slots with 10G of bandwidth.
The LNW59 also enables true 0x1 operation amongst the tributary slots by supporting hairpin cross-connections between unprotected
0x1 interfaces located in the same function or growth unit.
LNW59 supports STS-1, STS-3c, STS-12c, and STS-48c signal transport. It can cross-connect VTs in any of 192 STS-1s.
LNW59s may occupy Main slots 1 and 2.
All tributary circuit packs, with the exception of the LNW6 and
LNW7, are supported by the LNW59.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 - 1 3
Feature Release Plan
System Overview
•
Quad OC-48 optical interface (LNW62)
Quad OC-48 (LNW62) circuit packs support add/drop, UPSR, and
BLSR configurations, single- and dual-homing, revertive or nonrevertive linear 1+1 protection switching and 0x1 operation. A maximum of 15 BLSRs (between low-speed and high-speed slots) are supported per shelf.
The LNW62 provides 4 PTM (also known as SFP) ports capable of supporting 1.3LR1 and 1.5LR2 PTMs.
As an R7.0 circuit pack, the LNW62 does not have an on-board switch fabric and therefore can only be used with the LNW59 packs in the Main slots. All switching functions are performed on the VLF Main packs (LNW59).
LNW62 supports STS-1, STS-3c, STS-12c, and STS-48c signal transport. The LNW62 boasts a 10G backplane interface capacity and may occupy both Function and Growth slots, providing a total port density of 20 OC-48 ports per shelf if every Function and
Growth slot is equipped with an LNW62.
•
8-port optical/electrical GbE private line interface
(8 optical 1000BASE-SX/LX/ZX or electrical 1000BASE-TX ports)
(LNW64)
The LNW64 provides 8 private line, PTM (also known as SFP)
GbE ports. The ports can be equipped with 8 1000BASE-SX/LX/
ZX PTMs or 8 1000BASE-TX electrical PTMs. LNW64 can also support a mix of 4 electrical and 4 optical PTMs. The LNW64 contains 8 internal VCG ports supporting enhanced private line services such as virtual concatenation (VCAT) and Link Capacity
Adjustment Scheme (LCAS). LNW64 is OSP hardened and can only be used with VLF Mains (LNW59).
LNW64 supports STS-1 and STS-3c cross-connections with or without VCAT, and STS-12c cross-connections without VCAT.
All ports are capable of transmitting at wire speed (1000 Mbps) simultaneously, making full capacity of the pack 168 STS-1s.
With VLF Mains, LNW64 can occupy both slots 1 and 2 of a function/growth unit, making the total capacity of a system fully populated with LNW64s, 80 GbE private line ports.
...........................................................................................................................................................................................................................................................
1 - 1 4
365-372-300
Issue 8.0, September 2006
Feature Release Plan
System Overview
•
48-port DS3/EC1/TransMUX/Portless TMUX circuit pack (LNW20)
The LNW20 will be available in R7.0.1 (03/07). It provides 48 ports supporting DS3, EC1, and TMUX functionality on a portby-port basis. Each port can be individually provisioned as DS3 or
EC1 (unchannelized), or as TransMUX (channelized DS3s). With the LNW20, one high-density pack can be used for all DS3, EC1, and/or TransMUX applications.
The LNW20 can also function in portless mode. Portless mode does not utilize physical ports on the pack (those provisioned for portless that is). When operating in portless mode, LNW20 pulls
DS1s from channelized DS3 signals that enter DMX on a SONET
STS-1 interface on another pack (at least one side of the crossconnect is OCn/EC1) and converts them to VT mapped STS-1s.
This VT-mapped STS-1 is cross-connected at the VT level in the
Main packs to any interface that supports the signal structure today (DS1, channelized DS3, EC1, optical). Portless mode can be provisioned on a per-port basis when VLF Mains are used. When non-VLF Mains are used, odd numbered ports can be configured as portless and the corresponding even-numbered port will be unavailable for service.
LNW20 can be 1x1 protected or function in 0x1 unprotected mode. It supports hairpins to other packs in the shelf, and between ports on the same pack. LNW20 can occupy slots A1/A2 through
G1/G2 when the LNW59 VLF Main is used. LNW20 only functions in portless mode in G1/G2. Portless mode is only supported with certain Main packs, when the shelf is equipped with Main packs that don’t support portless mode, it can not occupy G1/G2 (see
Main packs that allow portless LNW20 operation
•
4-port optical SAN interface with Compression
—
FICON/ESCON/
Fibre-Channel (LNW73C)
The LNW73C is a Storage Area Networking (SAN) interface card designed to facilitate SAN distance extensions via the DMX platform using GFP-T (G.7041). The LNW73C differs from the
LNW73 in that it enables compression of SAN traffic. The
LNW73C is able to conserve up to 50% of bandwidth versus uncompressed SAN traffic in typical applications.
Like the LNW73, it utilizes PTM optics to provide the option of
FICON, ESCON, or Fibre-channel interfaces natively on the
DMX shelf. Each pack must be equipped to provide only one type of service (FICON/FC or ESCON) and can be housed in Slot A1,
B1, C1, D1, or G1. The LNW73C can operate at 1 Gbps or 2 Gbps
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 - 1 5
Feature Release Plan
System Overview
and in either Asynchronous or Synchronous transmission modes.
When operating in async Fibre Channel (FC) mode, 2 ports are available at 2Gbps FC, or 4 ports at 1Gbps FC, or 1 port at 2Gbps
FC and 2 ports of 1Gbps FC. When operating in synchronous FC mode, 1 port is available at 2Gbps FC, or 2 at 1Gbps FC. So, the total number of SA N interfaces on a DMX shelf is 20 when the
LNW73C is operating at 1G FC/FICON or ESCON, and 10 when it is set to 2G FC/FICON.
The R7.0 implementation of SAN compression enables a high throughput of up to four full-line rate FC-2G interfaces in a single pack.
•
Data Compression for SAN traffic
Release 7.0 supports data compression on new LNW73C SAN packs. The LNW73C is able to compress asynchronous Fibre
Channel traffic and conserve up to 50% of bandwidth versus uncompressed asynchronous FC traffic in typical applications.
Compression for asynchronous FC traffic is pre-standard and will be standardized by FC-BB-4. The R7.0 implementation of SAN compression enables a high throughput of up to two full-line rate
FC-2G interfaces in a single pack.
•
True 0x1
With the introduction of the VLF Main pack (LNW59) in R7.0,
DMX allows true 0x1 unprotected circuit packs. That means that any slot can be equipped with any pack (some restrictions apply).
For example, an LNW70 could be used to provide switched
Ethernet services in slot A1, while slot A2 could be equipped with another pack, like an LNW62. Two of the same circuit pack can also populate adjacent slots in the same group, yet certain restrictions apply. For more information on 0x1, including circuit pack/slot equipage restrictions, refer to Chapter 5.
The 0x1 OCn application replaces 0x1Sn functionality when VLF
Mains are used. 0x1Sn will still be supported when the shelf is equipped with non-VLF Mains. 0x1 is only available on the lowspeed/tributary packs, not on the Main (M1/M2) interfaces. When all lines on an OCn pack are set to 0x1, the pack becomes unprotected and the companion slot can be equipped with a different pack.
...........................................................................................................................................................................................................................................................
1 - 1 6
365-372-300
Issue 8.0, September 2006
Feature Release Plan
System Overview
•
Line timing from optical tributary packs
DMX can derive timing references from low-speed/tributary optical interfaces beginning in R7.0. Prior to R7.0, line timing references could only be derived from the signals entering the
Main circuit packs. DMX can now derive timing references form any optical line entering Main, Function Unit, or Growth slots.
All optical circuit packs can derive a 6.48MHz timing signal from an incoming optical line.
•
Link Aggregation on LNW70 LAN ports
DMX supports link aggregation on any two LNW70 LAN ports of the same rate (i.e. 100 or 1000 Mbps) operating in switched mode.
The ports must be located on the same pack and DMX supports a maximum of 8 Link Aggregation Groups (LAGs) per function unit/growth group.
Link aggregation can be used to enable bandwidth increases/ decreases and facility protection on LNW70 LAN ports.
Ordinarily, multiple Ethernet links between two bridges form loops (unless a spanning tree blocks all but one) so they can’t be used to increase bandwidth. Link Aggregation causes defined groups of links to be treated as a single logical link, making multiple LAN ports appear as one. In this way, bandwidth can be increased without requiring an upgrade to a higher rate link.
Link aggregation can also remove failed links automatically, thereby providing a means of facility protection. When a link fails, traffic is shifted to the remaining links in that LAG. More links than are needed can be added to the group and each is active until it fails (similar to utilizing LCAS protection for SONET tributaries).
•
QoS on EoS VCGs
Quality of service (QoS) on Ethernet over SONET (EoS) VCGs is designed to enable aggregation of diverse data streams in multiple topologies amongst LNW70 and LNW78 circuit packs. These topologies include packet rings, hub-and-spoke with LNW70 at the hub, and hybrid ring/hub-and-spoke with LNW70/LNW78 at the hub.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 - 1 7
Feature Release Plan
System Overview
QoS on EoS VCGs functions by giving EoS VCG ports the same classification options for incoming packets, rate control capabilities for Ethernet services (PIR, CIR), queuing/scheduling capabilities for outgoing, and the same packet transformation functions as on 802.3 LAN ports.
•
MAC address locking
DMX allows MAC locking on the LNW70. MAC locking prevents unauthorized users from gaining access to the network through an Ethernet port, thereby providing a level of security against intrusion attempts. MAC locking restricts access to a bridged Ethernet network by requiring that the source address of traffic entering a locked port be registered with that port. Any number of ports, LANs, VCG, or link aggregation groups (LAGs) can be locked. DMX permits registering of multiple addresses with a single entity.
•
Ethernet facility loopbacks
DMX supports facility loopbacks on the LNW70 and LNW78.
Facility loopbacks are used to test the integrity of the customer to provider network link by looping the signals back at the far end and comparing counts of sent and received frames.
Facility loopbacks are supported on both individual ports and
LAGs. Loopbacks on LAGs are permitted simultaneously for both ports in the group because they are treated as failed members allowing transmission on unlooped members. If a facility loopback is set up on a LAG, alarms are suppressed on both the member ports and the LAG.
•
Locked VT Cross-connections (aka VT locked bandwidth)
In the “locked” mode, DMX does not select the best signal from both rotations of a UPSR. Instead, traffic is added and dropped
(locked) from one rotation of the ring only (provisionable). The main advantage of locked VT cross-connections is the lack of
UPSR switching which results in the ability to reuse timeslots around a UPSR.
The ability to mix locked, unlocked, and pass-through VT1.5s within the same STS-1 was added in R6.0.2.
...........................................................................................................................................................................................................................................................
1 - 1 8
365-372-300
Issue 8.0, September 2006
Feature Release Plan
System Overview
•
Linear/Unprotected UPSR
In R7.0, DMX also allows both rotations of a ring to be used simultaneously. Prior to 7.0, if a 1WAY (as opposed to a pathprotected 1WAYPR) cross-connection was established with the source from a UPSR ring, the other side became unusable as the source (1WAY) or destination of a cross-connection (1WAY or
1WAYPR), except for pass-through cross-connections. This feature removes those restrictions.
DMX permits simultaneous 1WAY cross-connections sourced from the 2 associated ring channels in a UPSR application, simultaneous 1WAY cross-connection sourced from a ring channel, and 1WAY or 1WAYPR destined to the associated ring channel.
This feature removes the need for unswitched cross-connections on Ethernet/Data packs which don’t require VCG pairing, yet they will still be supported to ensure backwards compatibility.
•
Electrical 100/1000BASE-TX PTMs on LNW78 and LNW63
DMX supports 100BASE-TX and 1000BASE-TX electrical
PTMs (also known as SFPs) on the LNW78 and LNW63 circuit packs. Certain port/PTM equipage restrictions apply.
•
LNW78 RPR enhancements for R7.0
In addition to the various Ethernet networking capabilities detailed above for R7.0, the LNW78 RPR pack has been upgraded to support the following capabilities:
– VCG ports 17-22 are now available to provide EoS service.
This feature enables EoS port connectivity to RPR ring interfaces via the LNW78 faceplate and/or hairpin crossconnections.
– Standards-based LCAS
– Interconnection of multiple RPR rings on the same shelf or separate shelf using EoS VCGs.
– EOS private line support: adds EoS private line support to an
RPR core ring. Traffic can be managed with QoS support on
EoS VCGs.
– Support of Basic RPR Bridging. In past Releases, DMX only supported enhanced RPR bridging.
Highlighted Features From
Past Releases
Listed below are important features from past releases of the DMX:
New System Controller (LNW2)
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 - 1 9
Feature Release Plan
System Overview
The LNW2 contains a memory upgrade to support the enhanced feature sets of R6.0 and later releases.
The System Controller (SYSCTL) supports all DMX operations interfaces, including IAO LAN (OSI or TCP/IP), TL1, PC-CIT, office alarms, and miscellaneous discretes. The SYSCTL also supports DCC terminations for each optical line interface.
The SYSCTL circuit pack provides a microprocessor, nonvolatile memory to store the generic program software and provisioning database, and additional memory for system operation.
The new SYSCTL (LNW2) will continue to provide PC-CIT front access to the DMX via the IAO LAN and a serial RS-232 port (it also provides access via the LAN and serial ports located on the back of the
DMX shelf).
High Speed (network side) Service Interfaces
•
OC-192 HS Long-reach optical interface with on-board amplifier
(LNW60)
The LNW60 is an OC-192 long-reach OLIU with tone circuitry and an on-board, integrated amplifier. The LNW60 also includes an integrated, on-board amplifier capable of transmitting signals across spans as great as 127 km.
•
1-port OC-12 High-speed interface (LNW54)
•
OC-192 HS Long-reach optical interface (80 km)
DMX OC-192 Long-reach OLIUs (LNW555) are 1533.47 nm port units supporting OC-192 add/drop and UPSR and BLSR configurations, single- and dual-homing, non-revertive linear 1+1
(1+1 on OC-192 in R4.0) protection switching, and STS-1, STS-
3c, STS-12c, and STS-48c signal transport. The OC-192 OLIU can cross-connect VTs in any 48 STS-1s. LNW555s may occupy
Main slots 1 and 2.
•
OC-192 HS Long-reach optical interface
DMX OC-192 Long-reach OLIUs with tone circuitry (LNW57) are 1533.47 nm port units supporting OC-192 add/drop, UPSR and BLSR configurations, single- and dual-homing, non-revertive linear 1+1 protection switching, and VT1.5, STS-1, STS-3c, STS-
12c, and STS-48c signal transport. LNW57s may occupy Main slots 1 and 2.
•
OC-192 HS DWDM optical interface
...........................................................................................................................................................................................................................................................
1 - 2 0
365-372-300
Issue 8.0, September 2006
Feature Release Plan
System Overview
DMX OC-192 DWDM OLIUs (LNW523, LNW527 and
LNW554) are 1550 nm (see Table 10-36 for a list of tunable frequencies) port units supporting OC-192 add/drop and UPSR and BLSR configurations, single- and dual-homing, non-revertive linear 1+1 protection switching, and VT1.5, STS-1, STS-3c, STS-
12c, and STS-48c signal transport. These circuit packs may occupy Main slots 1 and 2.
•
OC-48 long-reach high-speed optical interface
The LNW32 high-speed circuit pack is a long-reach OC-48, 1310 nm optical line interface unit. The LNW32 supports OC-48 add/ drop, BLSR and UPSR configurations, single- and dual-homing, non-revertive linear 1+1 protection switching, and VT1.5, STS-1,
STS-3c, STS-12c, and STS-48c signal transport. The LNW32 contains a 48 STS-1 VT switch fabric and is OSP hardened.
•
OC-48 HS DWDM optical interface (passive optics)
(LNW221-259 and LNW121-159B)
DMX OC-48 High-speed DWDM OLIUs are passive optical port units, available in 32 different wavelengths. By using the DWDM port units and the Passive Optic Units (POUs), you are able to increase fiber capacity by a factor of 16 or 32. The OC-48 HS
DWDM OLIUs may occupy Main slots 1 and 2.
•
OC-12 High-speed optical interface
s
The OC-12 OLIUs are intermediate- (LNW48) or long- (LNW50) reach 1310 nm optical line interface unit.
•
20 Amp version of the High Capacity Shelf
The 20 Amp version of the high-capacity shelf contains all of the functionality of the standard DMX high-capacity shelf, but it is designed to function with a 20 Amp power supply.
•
Main Switch Pack (No optics, 96 STS-1 VT fabric)
The LNW80 may occupy Main slots 1 and 2 and contains NO interfaces on the faceplate of the pack. The LNW80 high-speed circuit pack is designed to save cost in CO hub applications where there is no need to transmit traffic over network-side interfaces.
LNW80 is best used in a DCS type of application. It can crossconnect signals amongst multiple low-speed tributary interfaces and perform VT mapping into OC-3/12/48 tributaries.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 - 2 1
Feature Release Plan
System Overview
Low Speed (tributary side) TDM and Ethernet Service Interfaces
•
OC-48 low-speed optical interface
Capacity of 10 low-speed OC-48 ports when all Function Unit groups (including Growth slots) are equipped with OC-48 OLIU circuit packs (1 bidirectional port per pack). Capacity of 5 OC-48 rings when ports are protected.
•
OC-48 LS DWDM optical interface (passive optics)
DMX OC-48 Low-speed DWDM OLIUs are optical port units, available in 32 different wavelengths. By using the DWDM port units and the Passive Optic Shelves, you are able to increase fiber capacity by a factor of 8, 16, or 32. The OC-48 LS DWDM OLIUs may occupy both the Function and Growth slots.
•
Dual OC-12 low-speed optical interface
Twenty OC-12 capacity when all Function Unit groups (including
Growth slots) are equipped with OC-12 OLIU circuit packs (2 ports per pack). 10 OC-12 capacity when signals are protected.
•
Quad OC-12 low-speed optical interface (48 STS-1 VT fabric)
Provides forty ports at OC-12 when all Function Unit groups
(including Growth slots) are equipped with LNW49 OC-12 OLIU circuit packs (4 ports per pack). These packs provide 20 OC-12 interfaces when signals are protected.
•
8-port OC-3 low-speed optical interface (48 STS-1 VT fabric)
(LNW45)
Provides eight OC-3 ports per pack, equaling a total interface density of 80 OC-3 ports when all Function Unit groups
(including Growth slots) are equipped with OC-3 circuit packs.
These packs provide forty ports of OC-3 capacity when signals are protected. The LNW45 utilizes PTM optics, allowing you to equip additional ports as necessary. It also contains a 48 STS-1s VT switch fabric that allows usage of all ports at full capacity for add/ drop, hairpinning, and/or VT ring closure applications.
•
Quad OC-3 low-speed optical interface (12 STS-1 VT fabric)
Provides forty ports at OC-3 when all Function Unit groups
(including Growth slots) are equipped with OC-3 OLIU circuit packs (4 ports per pack). These packs provide 20 OC-3 capacity when signals are protected.
•
56 Port E1 service support
...........................................................................................................................................................................................................................................................
1 - 2 2
365-372-300
Issue 8.0, September 2006
Feature Release Plan
System Overview
DMX supports 56 E1 signals on the LNW8 circuit pack. E1 signals are SDH/PDH signals at 2.048 Mbps. DMX supports performance monitoring on E1 signals.
•
48 port DS3/EC1 interface with DS3 loopbacks (LNW19B)
192 DS3/EC1 drop capacity when four Function Unit groups are equipped with LNW19B circuit packs (48 ports per pack, 1x1 hardware protected). The difference between the LNW19B and the previously released LNW19, is that the LNW19B provides the capability for DS3 terminal loopbacks that aid in testing, troubleshooting, and installation procedures.
•
56 port DS1 interface (LNW8)
224 DS1 drop capacity when four Function Unit groups are equipped with LNW8 circuit packs (56 ports per pack, 1x1 hardware protected).
•
48 port DS3/EC1 interface (LNW19)
192 DS3/EC1 drop capacity when four Function Unit groups are equipped with LNW19 circuit packs (48 ports per pack, 1x1 hardware protected).
•
Port-provisionable 12DS3/EC1 circuit pack
In early releases the 12DS3/EC1 circuit pack was switch selectable for DS3 or EC-1 service on a per-pack basis. DS3 or
EC-1 service can be provisioned on a per-port basis.
•
12-port DS1/DS3 TransMux circuit pack
DMX supports a 12-port Trans/MUX card that can collect various
DS1 signals from around a ring and combine them into a channelized DS3 signal.
•
6-port optical RPR Ethernet interface (two 1000BASE-X and four 100BASE-X ports) with PTM optics (LNW78)
The LNW78 provides two 1000BASE-X ports for GbE LAN applications and four 100BASE-X ports for fast Ethernet LAN applications at 100 Mbps. The first two ports (1-2) are for the GbE traffic. Ports 5-8 are for FE traffic, and ports 3 and 4 are not available until a later release. The LNW78 supports similar port, switching, and traffic management capabilities as the LNW70.
The LNW78 also provides standards compliant RPR switching per IEEE 802.17. LNW78 will support one RPR instance in R7.0 and two in the future. The LNW78 provides two internal Virtual
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 - 2 3
Feature Release Plan
System Overview
Concatenation Group (VCG) WAN ports (will support 4 in the future) with a total capacity of 2.5 Gbps capacity for Ethernet RPR traffic (24 STS-1s in each direction).
DMX supports a total add/drop capacity of 10 RPR GbE ports and
20 RPR FE ports if all slots are equipped with LNW78 circuit packs.
•
GbE (1000 Mbps) Private Line circuit pack (LNW63)
The LNW63 enables support of GbE private line on DMX. The
LNW63 provides 4 PTM ports that can be equipped with longreach (1000 BASE-LX) 1310 nm and/or short-reach (1000 BASE-
SX) 850 nm single mode PTMs.
•
8-port optical Ethernet interface (four 1000BASE-X and four 100BASE-LX ports) (LNW70)
The LNW70 supports all R4.0 and R5.0 Ethernet enhancements
(see descriptions below), provides 32 internal Virtual
Concatenation Group (VCG) WAN ports with a total capacity of
2.5 Gbps with SONET protection and 5 Gbps without SONET protection. The LNW70 has a total Ethernet switching capacity of
9 gigabits per second (Gbps).
•
4-port optical SAN interface
—
FICON/ESCON/Fibre-Channel
(LNW73)
The LNW73 is a Storage Area Networking (SAN) interface card designed to facilitate SAN distance extensions via the DMX platform using GFP-T (G.7041). It utilizes PTM optics to provide the option of FICON, ESCON, or Fibre-channel interfaces natively on the DMX shelf.
•
24 port 100BASE-TX (10/100Mbps) Private Line Ethernet interface
(LNW71)
Enhanced 10/100 Mbps Ethernet interface designed to enable Fast
Ethernet Private Line services. 96 10/100 Mbps drop capacity when four Function Unit groups are equipped with 10/100 Mbps circuit packs (24 ports per pack).
•
24-port optical/electrical Fast Ethernet private line interface
(8 optical 100BASE-LX and 16 electrical 100BASE-TX ports) with
R5.0 Ethernet enhancements (LNW74)
The LNW74 provides 8 100BASE-LX optical ports with front
(faceplate) access and 16 electrical 100BASE-TX ports with rear access at 10/100 Mbps for enhanced fast Ethernet private line applications. The LNW74 contains 24 internal 100 Mbps WAN
...........................................................................................................................................................................................................................................................
1 - 2 4
365-372-300
Issue 8.0, September 2006
Feature Release Plan
System Overview
ports supporting enhanced private line services such as low-order virtual concatenation (VT1.5) and Link Capacity Adjustment
Scheme (LCAS). LNW74 is OSP hardened.
•
100BASE-TX (10/100T) Ethernet interface
Ninety-six 100BASE-TX drop capacity when four Function Unit groups are equipped with 10/100T circuit packs (24 ports per pack).
•
1000BASE-SX/LX (1G SX/LX) optical Ethernet interfaces
Ten 1000BASE-SX/LX drop capacity when all Function Unit groups (including Growth slots) are equipped with 1G SX and/or
1G LX circuit packs (2 ports per pack).
•
Electrical Fast Ethernet/GbE PTM for LNW70
•
Pluggable Transmission Module (PTM) optics
The Pluggable Transmission Module (PTM) optics, also known as
SFP optics, are used on the LNW37, LNW49. LNW45, LNW63,
LNW70, LNW73, LNW74, and LNW78 packs. PTM optics are
“pluggable” optics. PTM optics also allow one pack to support various span lengths (short/intermediate, and long-reach).
•
Fiber Management Brackets
In the interest of helping customers organize the physical networking in their offices, DMX provides a fiber management bracket that mounts to the apparatus blanks used in the unoccupied slots of the shelf. This bracket has 8 hooks where fibers can be set until the pack to which they will be attached are installed.
•
Detectable Blank Circuit Packs
DMX supports detectable blank circuit packs: LNW98 in unequipped Function and Growth slots, LNW97 in an unequipped
M2.
•
In-service Electric Continuity Test Tool
The In-service Electrical Continuity Test Tool (LNW93) is very similar to the LNW94 test tool except that it has no backplane connectors for DS1 ports #1-28 or for DS3 ports #1-24. When the
LNW93 is plugged in, it makes no contact with the wires on the backplane for those lower ports. Since there is no physical connection, the LNW93 does not interfere with the service of the pack in the other slot of the function unit.
•
Electric Continuity Test Tool
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 - 2 5
Feature Release Plan
System Overview
The Electrical Continuity Test Tool (LNW94) can be placed in any Function slot on the DMX shelf. It is used to test the cables which will be connected to DS1, DS3, or Ethernet electrical interfaces. LNW94 tests the integrity of electrical cables to both identify where trouble exists and which cables or DSX panels are faulty prior to installation and turn up.
•
Optical Amplifiers
External amplifiers, enabling transmission for OC-48/192 spans of up to 140 km.
In-service upgrades
•
In-service upgrade from LNW1 to LNW2
DMX supports an in-service upgrade from the LNW1 to LNW2
SYSCTL on shelves equipped with software Release 5.x. Use of the LNW2 SYSCTL requires that the shelf be equipped with R6.0 or later software.
•
OC-48 to OC-192 HS BLSR and UPSR in-service upgrade
DMX supports in-service upgrades, from OC-48 to OC-192
UPSRs and from OC-48 to OC-192 BLSRs (in-service OC-48 to
OC-192 upgrades are currently supported only when using OC-
192 packs released prior to R7.0.
•
OC-12 to OC-48 HS UPSR in-service upgrade
DMX supports in-service upgrades, from OC-12 to OC-48 (small fabric packs) UPSRs.
•
In-service upgrade from low-density to high-density electrical interface circuit packs
.
DMX allows an in-service upgrade from either the LNW16 to the
LNW19/19B or the LNW6 and LNW7 to LNW8.
•
In-service upgrade from low-density (LNW16) to high-density
(LNW19/19B) electrical interface circuit packs
.
DMX allows an in-service upgrade from the LNW16 (12 DS3 ports) to the LNW19 or LNW19B (48 DS3/EC-1 ports) circuit packs.
...........................................................................................................................................................................................................................................................
1 - 2 6
365-372-300
Issue 8.0, September 2006
Feature Release Plan
System Overview
Network Configurations/Capabilities
•
OC-192/48/12 HS linear optical extension
The DMX supports point-to-point, 1+1 protected linear optical extension from the circuit packs in the MAIN slots.
•
OC-192/48/12 HS unidirectional path switched ring (UPSR)
•
OC-48/192 HS Bidirectional line switched ring (BLSR)
with VT support
The DMX supports OC-48/192 BLSR at VT1.5, STS-1, STS-3c,
STS-12c, and STS-48c (OC-48 BLSRs do not support STS-48c) level. DMX OC-48/192 BLSRs also support VT grooming and squelching.
•
Low-speed OC-48 UPSR
•
1+1 protected low-speed linear optical extensions (OC-3/12/48)
•
Bidirectional Optimized 1+1 Linear Protection Switching per ITU-T
G.841 Annex B
DMX supports this feature on all OC-n interfaces. Bidirectional optimized 1+1 is designed to enable interoperability between
DMX and SDH equipment. It is a separate switching scheme from standard 1+1 bidirectional and does not work with standard 1+1.
•
Bidirectional 1+1 Protection Switching
DMX supports revertive and non-revertive bidirectional 1+1 protection switching in all OC-n interfaces in addition to linear
1+1 protection switching.
•
Support of Resilient Packet Ring (RPR) per IEEE 802.17
•
GbE Private Line
Allows DMX to provide dedicated bandwidth (up to 1000Mbps) for individual customers.
•
0x1Sn unprotected interfaces
DMX supports 0x1 provisioning of an optical port in 1 slot of a low-speed (function unit) pair. 0x1Sn is not supported on HS interfaces. The companion port to the one provisioned for 0x1Sn is inactive. 0x1Sn is provisionable on per port/port pair basis.
•
Locked DS1/DS3 Cross-connections
In the “locked” mode, DMX does not select the best signal from both rotations of a UPSR. Instead, traffic is added and dropped
(locked) from one rotation of the ring only (provisionable). The
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 - 2 7
Feature Release Plan
System Overview
main advantage of locked DS1/DS3 cross-connections is the lack of UPSR switching which results in the ability to reuse timeslots around a UPSR.
•
DS1s 1x1 protected
DS1s are 1x1 equipment protected at the pack level. The LNW8
56DS1 pack provides support for up to 224 DS1s.
•
DS3s 1x1 protected
DS3s are 1x1 equipment protected at the pack level. The LNW19/
LNW19B 48 DS3 packs provides support for up to 192 DS3s
•
VT1.5 granularity
Fully-flexible VT1.5 granularity across up to 48 STS-1s. The number of VTs supported varies on a per-pack basis.
•
VT and Ethernet Hairpinning
•
Ethernet Enhancements for R4.0
•
Ethernet Enhancements for R5.0
•
Utilization of Simple Network Management Protocol (SNMP)
DMX allows SNMP to be used for monitoring alarms and traps relative to the Ethernet circuit packs.
•
Utilization of Simple Network Management Protocol (SNMP) for
TDM interfaces
DMX allows SNMP to be used monitoring alarms, traps, and performance monitoring parameters relative to the DS1/E1 and
DS3/EC-1 circuit packs.
•
R5.1 Ethernet Enhancements (supported by LNW70)
– Committed and Peak rate controls (CIR and PIR)
– 4 classes of services
– 4 1000BASE-X and 4 100BASE-LX port density with PTM optics (simultaneously)
– Larger MAC tables
– 32 VCGs (star configuration) per G.707
– 16 virtual switches with independent VLAN space per virtual switch
• DMX
Ethernet interworking with DDM-2000
The DDM-2000 circuit pack can interwork with the LNW71 and
LNW74 circuit packs.
•
VLAN Transparency
...........................................................................................................................................................................................................................................................
1 - 2 8
365-372-300
Issue 8.0, September 2006
Feature Release Plan
System Overview
•
1 Mbps Ethernet rate shaping
•
IP DiffSrv packet priority for VoIP applications
R6.0 allows DMX to use an IP DiffSrv Code Point (DSCP) in the header of IP packets to enable differentiated levels of services for individual customers and their data streams.
•
Performance monitoring (PM) on VLANs
DMX can provide PM on UPSR VT1.5, STS-n pass-throughs, and
BLSR STS-n pass-throughs.
•
Support of 4093 Virtual Local Area Networks (VLANs) and stacked
VLANs per Ethernet circuit pack
•
Pipe-mode (adaptive rate) cross-connections
Pipe mode is a fault and PM feature whereby fault and PM are reported independently for each constituent signal within a crossconnection rather than simply at the xc rate.
•
Increased number of OSI associations
The maximum number of OSI associations per TCP connection has been increased from 64 to 300. The maximum number of OSI associations for TL1 per GNE has been increased from 200 to 300.
•
250 NEs in a Level 1 routing area
The maximum number of NEs per OSI Level 1 routing area has been increased from 50 to 250.
•
Alarm Severity Assignment Profiles (ASAPs)
•
Revertive Unidirectional and Bidirectional 1+1
DMX now supports revertive and non-revertive unidirectional and bidirectional 1+1.
•
VT grooming on Low-speed Interfaces (LNW45 and 49)
•
WaveStar BandWidth Manager, FT-2000, LambdaUnite, and 2.5G/
10G interworking over OC-48 BLSRs
•
Single- and dual-homed 0x1 ring tributaries
: OC-3, OC-12, OC-48
•
BLSR auto ring discovery for BLSR interworking
•
FTP/FTAM Gateway
Also referred to as FTTD (File Transfer Translation Device), the
FTTD allows DMX to function as a Gateway Network Element
(GNE) that can facilitate the download of files located at FTP servers to remote NEs connected to the DMX.
•
UPSR and BLSR bridge and roll cross-connections
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 - 2 9
Feature Release Plan
System Overview
Allows DMX to move cross-connections within or between an
OC-n with minimal hits to traffic.
•
OC-12/48/192 Facility Loopbacks
•
OC-3 Facility Loopbacks
With the release of LNW37, DMX supports OC-3 facility loopbacks in addition to the OC-12/48/192 facility loopbacks supported in previous releases.
•
UPSR Dual Ring Interworking (DRI)
ANSI/Bellcore compliant DRI (through drop and continue method) with interconnected rings (OC-3/12/48/192 interfaces)
•
Non-preemptible Unprotected Traffic (NUT)
DMX allows the manual provisioning of NUT on BLSRs. NUT allows the DMX to host packet rings over BLSRs.
•
SS bits per pack
By default DMX transmits 00 in the outgoing SS pointer bits for compatibility with SONET interfaces. DMX provides the ability to set the outgoing SS bits to 10 on a LS optical pack basis for compatibility with older SDH equipment. DMX is provisionable to support SS bits on a per pack basis. This prevents LOP defects and allows SONET/SDH interworking.
•
IP communications over DCC channel
Synchronization
•
Embedded Stratum 3 Timing Generator
The OC-12/48/192 high-speed circuit packs contain an embedded
Stratum 3 timing generator. This timing generator is used when the DMX is configured in a free running mode.
•
DS1 Timing Output
DMX can generate a DS1 timing output to time other externallytimed systems. The DS1 output is derived from a line reference.
•
S1 Byte Synchronization Messaging
DMX uses the S1 byte of the SONET overhead to pass timing status information to different nodes in an access transport network.
•
Network Time Protocol (NTP)
NTP assures accurate time keeping with reference to radio and atomic clocks located on the Internet.
...........................................................................................................................................................................................................................................................
1 - 3 0
365-372-300
Issue 8.0, September 2006
Feature Release Plan
System Overview
Operations
•
Telcordia support of LCAS, VCAT, and diverse routing
•
Navis
™
Optical Management System (OMS) R3.1 support
Navis™ OMS R3.1 can be used to manage operations on DMX
R5.0.
•
TIRKS (R20.0)/NMA (R14.0)/TRANSPORT (R3.2)
DMX is supported by Telcordia OSs TIRKS, NMA, and
TRANSPORT.
•
Target ID Address Resolution Protocol (TARP)
DMX is compatible with any other-vendor NEs that support
TARP, OSI, IAO LAN, and TL1/X.25 as specified in Telcordia
Technologies GR-253.
•
Transmission Control Protocol/Internet Protocol (TCP/IP)
Provides access to Navis ™ Optical EMS or PC-CIT over TCP/IP
LAN to a DMX and subtending DMX, DDM-2000, and other NEs that support DMX operations interworking.
TCP/IP also enable software downloads via FTP through the LAN
CIT and RS232 CIT ports located at the front of the high-speed
(network side) circuit packs in the MAIN slots of the DMX shelf.
•
Level 1 Area Provisioning
•
Level 2 Routing
•
OSI seven-layer protocol stack
Provides interworking using the standard Open Systems
Interconnection (OSI) seven-layer protocol stack over the data communications channel (DCC).
•
WaveStar CIT
The CIT manages the DMX system through the LAN/Serial ports, providing TL1 messaging, software download, and full operations, maintenance, and provisioning functions through a
Graphic User Interface (GUI).
•
Product family 2000 and WaveStar product family Operations interworking (OI)
OI compatibility with Product Family 2000 (DDM-2000 and FT-
2000), and WaveStar Product Family.
•
Multivendor Operations interworking (OI)
DMX supports interoperability with many other vendors. Ask your account representative for more information.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 - 3 1
Feature Release Plan
System Overview
•
Utilization of Simple Network Management Protocol (SNMP)
DMX allows SNMP to be used in monitoring alarms and traps relative to the Ethernet circuit packs.
•
Test Access
Test access, a traditional DCS function, allows the user visibility into any VT1.5/STS-1 signal in the network. Test access aids users in turning up connections and in identifying faults in existing service connections. DMX supports two different types of test access. The non-intrusive method simply taps the VT1.5/STS-
1 channel as it passes through the system and routes it to an external testing device. The more intrusive mode splits the VT1.5/
STS-1 from the incoming signal and sends it to an external testing device. Test access facilitates DMX functioning in a DCS application.
•
Proxy Address Resolution Protocol (ARP)
•
Office Alarm support
•
IAO-LAN support (front and rear)
•
In-service node additions
•
Remote alarm support
•
EIA-RS-232 PC-CIT (serial port front and rear access)
•
Local and Remote Software Download capability
•
AITS support
•
Ring Circuit Audits
•
Auto-generated Squelch Map
Environmental and Packaging
•
EMC, UL 605950, NEBS Level 3, CSA
...........................................................................................................................................................................................................................................................
1 - 3 2
365-372-300
Issue 8.0, September 2006
2 Features
Overview
............................................................................................................................................................................................................................................................
Purpose
This chapter briefly highlights the features of the DMX Access
Multiplexer. These features are more thoroughly described in Chapter
3, “Network Topologies,” Chapter 4, “Product Description,” Chapter 5,
“System Planning and Engineering”, and Chapter 6, “Operations,
Administration, Maintenance, and Provisioning,” as applicable.
Contents
The following topics are included in this chapter:
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
2 - 1
Features
Hardware Features
............................................................................................................................................................................................................................................................
Overview
This section briefly describes the major hardware related features supported through Release 7.0 of the Metropolis
®
DMX Access
Multiplexer.
Below is a list of the sections included in Hardware Features:
• DMX High Capacity Shelf
• Network interface circuit packs (those housed in the MAIN slots of the DMX shelf)
• Optical, tributary interface circuit packs
• Electrical, tributary interface circuit packs
• Ethernet circuit packs
• Other hardware features
Important!
For more detailed information on the capabilities of these circuit packs, refer to the sections entitled “Circuit Packs” in
Chapter 4. For technical specifications refer to Chapter 10.
DMX High Capacity Shelf
The high capacity shelf is not software dependent. This design incorporates additional DS1/E1 and DS3/EC-1 interfaces that enable the DMX to support 224 DS1s/E1s or 192 DS3s/EC-1s. In order to support this amount of traffic, the DMX high capacity shelf must be equipped with high density DS1 and DS3 circuit packs.
This shelf is available in both 20 Amp and 30 Amp versions. The 20
Amp version has no restrictions as to circuit pack slot equipage through
R7.0. The 30 Amp version of the shelf is intended to provide “future proofing”.
...........................................................................................................................................................................................................................................................
2 - 2
365-372-300
Issue 8.0, September 2006
Hardware Features
System Controller-
SYSCTL (No Network
Interfaces)
Features
The DMX supports two SYSCTLs:
• LNW1— The SYSCTL provides communication with other circuit packs on the DMX shelf. The SYSCTL supports all DMX operations interfaces, including IAO LAN (OSI or TCP/IP), TL1,
PC-CIT, office alarms, and miscellaneous discretes. The SYSCTL also supports DCC terminations for each optical line interface.
The LNW1 will work with any software release prior to R6.0, but the LNW2 must be used with R6.0 and later Releases.
• LNW2 — This version of the SYSCTL contains a memory upgrade to support the enhanced feature sets of R6.0 and upcoming releases.
Network Interface Circuit
Packs
This section briefly details the network interface circuit packs available through Release 7.0 of the DMX. “Network Interface” is used to refer to the high-speed circuit packs, housed in the MAIN slots of the DMX shelf, and used to provide the connection to the core-side of the network.
Main Switch Circuit Pack (No Network Interfaces)
The DMX supports the following main switch cards:
• LNW80— headless pack to facilitate switching amongst multiple tributary interfaces, resides in Main slots, provides no high speed or network side optics, VT mapping in 96 STS-1s, OSP hardened
VLF Main Circuit Pack (LNW59) (R7.0)
In R7.0, DMX introduces the LNW59 OC-192 Very Large Fabric
(VLF) Main circuit pack. LNW59 drastically increases the overall switch fabric capacity of DMX. It also provides two ports that can host
PTMs (also known as XFPs). LNW59 can support 1.3SR1, 1.5IR2, and
1.5LR2 pluggable optics. It can also function in headless mode, providing switching and synchronization functionality without being equipped with optics.
For overall capacity, the LNW59 boasts a 20G optical main with a
240G centralized STS switch fabric, 30G centralized VT termination capacity, and 40G VT switch fabric. When DMX is equipped with the
LNW59 VLF Main, all switching takes place on the LNW59. The switch fabrics on the low-speed, tributary optical circuit packs are disabled. The LNW59 further upgrades the shelf’s overall capacity by enabling the Function and Growth slots to house circuit packs with up to 10G bandwidth.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
2 - 3
Hardware Features
Features
The LNW59 also enables true 0x1 operation amongst the tributary slots by supporting hairpin cross-connections between unprotected 0x1 interfaces located in the same function or growth unit.
All tributary circuit packs, with the exception of the LNW6 and LNW7 are supported by the LNW59.
OC-192 Network Interface Circuit Packs
The DMX supports the following OC-192 network interface cards:
• LNW56— (1550nm, intermediate-reach, VT mapping across 48
STS-1s)
• LNW57— (1533.47 nm, long-reach, VT mapping across 48
STS-1s, 80 km reach, with SBS tone circuitry)
• LNW58— (1310nm, short-reach, VT mapping across 48 STS-1s)
• LNW59— (4 ports, 1.3SR1, 1.5IR2, and 1.5LR2 PTM optics,
240G centralized STS switch fabric, 30G centralized VT termination capacity, and 40G VT switch fabric)
• LNW60— (1533.47 nm, long-reach, VT mapping across 48
STS-1s, with SBS tone circuitry, and on-board optical amplifier)
• LNW523, LNW527 and LNW554— (DWDM, full VT access,
4-frequency tunable laser. The LNW523 is being DA’d and will no longer be available as of 6/30/07.)
• LNW555— (1550nm, long-reach, VT mapping across 48 STS-1s,
80 km reach)
OC-48 Network Interface Circuit Packs
The DMX supports the following OC-48 network interface cards:
• LNW26B— (1310nm, long-reach, VT mapping across 12
STS-1s)
• LNW27— (1310nm, long-reach, VT mapping across 48 STS-1s)
• LNW28— (1310nm, long-reach, VT mapping across 12 STS-1s,
OSP hardened). The LNW28 will no longer be available as of
5/28/06.
• LNW29— (1550nm, long-reach, VT mapping across 48 STS-1s)
• LNW32— (1310nm, long-reach, VT mapping across 48 STS-1s,
OSP hardened)
• LNW76— (1310nm, short-reach, VT mapping across 48 STS-1s)
• LNW77— (1310nm, intermediate-reach, VT mapping across 12
STS-1s)
...........................................................................................................................................................................................................................................................
2 - 4
365-372-300
Issue 8.0, September 2006
Hardware Features
Features
• LNW121B-159B— (DWDM, VT mapping across 12 STS-1s, the
LNW121B, 123B, 131B, 135B, 137B, 143B, 145B, 147B, 149B,
157B, and 159B packs are no longer available. All other 100 series packs are still be available.
• LNW221-259— (high-speed, DWDM, 1550nm, long-reach, VT mapping across 48 STS-1s, the LNW221, 243, and 257 packs are no longer available. All other 200 series packs will still be available.)
OC-12 Network Interface Circuit Packs
The DMX supports the following OC-12 network interface card:
• LNW48— (1310nm, intermediate-reach, VT mapping across 12
STS-1s, OSP Hardened)
• LNW50— (1310nm, long-reach, VT mapping across 12 STS-1s,
OSP Hardened)
• LNW54— (1550nm, long-reach, VT mapping across 12 STS-1s,
OSP Hardened)
Optical, Tributary Interface
Circuit Packs
DMX supports the following optical, tributary interface circuit packs:
• OC-3— LNW36 (1310nm, long-reach, 12 STS-1 VT fabric
,
OSP hardened, 4 ports. The LNW36 is being DA’d and will no longer be available as of 12/31/07.)
• OC-3— LNW45 (PTM optics, OSP hardened, 8 ports,
VT mapping across 48 STS-1s)
• OC-3— LNW37 (PTM optics, OSP hardened, 4 ports,
VT mapping across 12 STS-1s)
• OC-12— LNW46 (1310nm, long-reach, 12 STS-1 VT fabric, OSP hardened, 2 ports. The LNW46 is being DA’d and will no longer be available as of 12/31/07.)
• OC-12— LNW49 (PTM optics, 48 STS-1 VT fabric, 4 ports,
OSP)
• OC-48— LNW31 (1310nm, intermediate-reach, 1 port,
VT mapping across 12 STS-1s)
• OC-48— LNW62 (R7.0) (1.3LR1 and 1.5LR2 PTM optics, 4 ports, requires VLF Main- LNW59)
• OC-48— LNW421-459 (low-speed, DWDM, 1550nm, long-reach, VT mapping across 12 STS-1s, the LNW421, 423,
431, 433, 435, 437, 443, 445, 457 packs are no longer available.
All other 400 series packs are still be available.)
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
2 - 5
Hardware Features
Features
Electrical, Tributary
Interface Circuit Packs
DMX supports the following electrical, tributary interface circuit packs:
• 28DS1— LNW6 (28 ports, OSP hardened, not supported on shelves equipped with LNW59 VLF Mains)
• 28DS1PM— LNW7 (28 ports, enables PM functionality on DS1 interfaces, OSP hardened, not supported on shelves equipped with
LNW59 VLF Mains)
• 56DS1/E1 — LNW8 (56 ports, enables PM functionality on DS1 and E1 interfaces— E1 functionality provisionable on a per pack basis, OSP hardened)
• 12DS3/EC1— LNW16 (12 ports, DS3 or EC-1 service is provisionable on a per-port basis)
• 48DS3/EC1— LNW19 (48 ports, DS3 or EC-1 service is provisionable on a per-port basis, OSP hardened)
• 48DS3/EC1— LNW19B (48 ports, DS3 or EC-1 service is provisionable on a per-port basis, supports DS3 loopbacks, OSP hardened)
• DS1/DS3 TransMUX — LNW18 (12-port, capable of collecting various DS1 signals from around a ring and combining them into channelized DS3 signals, OSP hardened)
• DS1/DS3 TransMUX/Portless — LNW20 (R7.0) (48-port, DS3,
EC1, and TMUX functionality on a port-by-port basis, supports channelized or unchannelized DS-3s, also offers a portless mode wherein the pack pulls DS1s from channelized DS3 signals that enter DMX on a SONET STS-1 interface (on another pack) and then converts them to a VT mapped STS-1, OSP hardened)
Ethernet/ Interface Circuit
Packs
DMX supports the following Ethernet interface circuit packs:
• Fast Ethernet— LNW66 (24 ports, 10/100 Mbps)
• Fast Ethernet— LNW71 (24 ports, 10/100 Mbps, enhancements to enable Ethernet private line services, The LNW71 is being DA’d and will no longer be available as of 3/1/08.)
• 24-port Optical/Electrical Fast Ethernet Private Line— LNW74 (8 optical 100BASE-FX with front, faceplate access and 16 electrical
100BASE-TX ports with rear access, supports R5.0 and 5.1
Ethernet enhancements and PTM optics)
...........................................................................................................................................................................................................................................................
2 - 6
365-372-300
Issue 8.0, September 2006
Hardware Features
Features
• 8-port Optical/Electrical Gigabit Ethernet Private Line— (R7.0)
LNW64 (8 optical 1000BASE-SX/LX/ZX or 8 electrical
1000BASE-TX PTMs, also supports a mix of 4 optical and 4 electrical PTMs, OSP hardened, 168 STS-1 capacity, requires
VLF Mains- LNW59)
• Gigabit Ethernet (GbE)— LNW67 (2 ports, 1 gigabit each, short reach. The LNW67 is being DA’d and will no longer be available as of 3/1/08.)
• GbE— LNW68 (2 ports, 1 gigabit each, long reach, The LNW68 is being DA’d and will no longer be available as of 3/1/08.)
• Gigabit Ethernet (GbE)/Fast Ethernet (10/100 Mbps)— LNW70
(four 1000BASE-X or 10/100/1000BASE-T and four
100BASE-FX ports) with R5.0 and 5.1 Ethernet enhancements and PTM optics
• FC-DATA— LNW73 (4 ports, support of FICON, ESCON, or
Fibre-Channel interfaces using PTM optics) Pack must be equipped with only one type of PTM: either FICON/FC or
ESCON.
• FC-DATA (R7.0)— LNW73C (4 ports, support of FICON,
ESCON, or Fibre-Channel interfaces with compression) Identical to the LNW73, except that is supports compression of SAN traffic, resulting in an increase of bandwidth efficiency to the order of 100%.
• 4-port Optical Gigabit Ethernet Private Line— LNW63 (4 optical
1000BASE-X ports), supports R5.0 and 5.1 Ethernet enhancements and PTM optics. Can be equipped with long-reach
(1000 BASE-LX) 1310 nm and/or short-reach (1000 BASE-SX)
850 nm single mode PTMs.
• RPR Pack— LNW78 (two 1000BASE-X and four 100BASE-FX ports) supports GbE and FE interfaces via PTM optics. Similar switching and traffic management capabilities to the LNW70, added support of standards compliant RPR (IEEE802.17)
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
2 - 7
Hardware Features
Features
Other Hardware Features
DMX also supports the following hardware:
External Optical Amplifiers
For OC-48/192 spans of up to 140km, Lucent Technologies offers external optical amplifiers. The external optical amplifier is a stand-alone shelf and can be used with both OC-48 and OC-192 optics.
External optical amplifiers consist of one booster and one pre-amplifier part. The booster part is connected via a Dispersion Compensation
Module (DCM) to the transmit interface of the respective OC-192 or
OC-48 port unit. The pre-amplifier part is connected by means of a
DCM to the receive interface of the associated port unit.
Passive Optics Units (POUs)
The Lucent Passive Optics Units (POUs) are a lower-cost solution to using DWDM for transmitting large amounts of traffic on one fiber.
This module fits into a bay frame, but reduces the number of DMX shelves in a bay to three. The box does not require any electrical powering.
POU shelves are available to support the following applications:
• Optical add-drop module (OADM): 1, 2, or 4 wavelengths
• Optical add-drop module (OADM): one 1310 nm port and four
1550 nm ports
• 16 unidirectional/bidirectional wavelengths (2 versions):
MUX/DMUX
• 32 wavelengths; 16 unidirectional/bidirectional wavelengths with a wavelength interleaver used to add another 16 wavelengths:
MUXINT/DMUXINT
Pluggable Transmission Modules (PTMs)
PTMs, also known as SFPs and XFPs (LNW59 only), are used on the
LNW37/45/49/59/62/63/64/70/73/73c/74/78 packs. PTM optics are
“pluggable” optics. This means that the circuit pack does not come equipped with optics. The customer orders the number and type of optics required at the time of installation. Additional optics can be ordered as new services are required. Thus DMX interface density is made more scalable to meet the unique needs of each customer.
The PTM optics also allow for some versatility in the span lengths and rates that can be covered by the same pack.
...........................................................................................................................................................................................................................................................
2 - 8
365-372-300
Issue 8.0, September 2006
Hardware Features
Features
Electrical Fast Ethernet/GbE PTM
The LNW64/70/78 now supports a dual function electrical Pluggable
Transmission Module (PTM) that is provisionable for 100 or 1000
Mbps (electrical FE or GbE) traffic. It conforms to the IEEE802.3 standards for 100BASE-T and 1000BASE-T in its respective settings
(IEEE802.3z and IEE802.3ab). Connectivity is provided for an RJ-45
Cat 5 cable and the PTM has a maximum span length of 100 meters.
This provisionable PTM can occupy ports 1-4 on the LNW64 and
LNW70. Ports 5 through 8 on both packs are always reserved for optical Fast Ethernet PTMs. This PTM can occupy ports 5-8 on the
LNW78. Ports 1 and 2 are reserved for optical GbE and port 3 and 4 are not usable at this time.
High-capacity 20 Amp Shelf
The 20 Amp version of the high-capacity shelf contains all of the functionality of the 30 Amp DMX high-capacity shelf, but it is designed to function with a 20 Amp power supply. This can save customers considerable investment in power cables. There are no restrictions through R6.0 resulting from the lower amperage given the circuit packs that are currently available through R6.0.
Important!
With the LNW59 VLF Main pack, available in
R7.0, overload and overheating in the 20A Standard Shelf is a possibility given certain combinations of circuit packs in the tributary slots. The LNW59 is not necessarily precluded from use in the 20 Amp shelf, but guidelines provided later in this document must be followed to ensure proper functioning of the 20
Amp shelf when it is equipped with the LNW59.
The power density of certain system configurations may also preclude the use of more than two DMX shelves per frame in
NEBS environments. See the section entitled
for more information.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
2 - 9
Hardware Features
Features
Cable Management Bracket
In the interest of helping customers organize the physical networking in their offices, DMX provides a fiber management bracket that mounts to the apparatus blanks used in the unoccupied slots of the shelf. This bracket has 8 hooks where fibers can be set until the pack to which they will be attached is installed.
The bracket is designed to facilitate the organization and storage of prewired fibers that are expected to carry service to the shelf in the future. These brackets attach to the apparatus blanks via PEM nuts on the faceplate. PEM Nuts or PEM Fasteners are mounted flush on the faceplate. They provide a fixed receptacle to which the bracket can be screwed in.
This feature is available on both the standard and detectable apparatus blanks and also allows visibility via the CIT.
Electrical Continuity Test Tool (LNW94)
DMX supports a circuit pack designed to aid technicians in the installation and maintenance of Electrical interfaces and cables. The
Electrical Continuity Test Tool (LNW94) can be placed in any
Function Unit slot (A, B, C, and D) on the DMX shelf. It is used to test the cables which will be connected to DS1, DS3, or Ethernet electrical interfaces. LNW94 tests the integrity of electrical cables to both identify where trouble exists and which cables or DSX panels are faulty prior to installation and turn up.
...........................................................................................................................................................................................................................................................
2 - 1 0
365-372-300
Issue 8.0, September 2006
Hardware Features
Features
In-service Electric Continuity Test Tool (LNW93)
The In-service Electrical Continuity Test Tool (LNW93) test circuit pack is used for upgrades in the DMX high capacity shelf. An in-service shelf might have a function unit with low capacity DS1
(LNW6 or 7) or DS3 (LNW16) packs. When these packs are upgraded with higher capacity packs (DS1, LNW8; DS3, LNW19/19B), as part of the upgrade procedure, new DS1 or DS3 connectorized cables are added to the DSX cross-connect frames and to the DMX shelf. The
LNW93 pack is used to test out the new wiring without disrupting traffic on the in-service pack.
The LNW93 is very similar to the LNW94 test tool except that it has no backplane connectors for DS1 ports #1-28 or for DS3 ports #1-12.
When the LNW93 is plugged in, it makes no contact with the wires on the backplane for those lower ports. Since there is no physical connection, the LNW93 does not interfere with the service of the pack in the other slot of the function unit. The LNW93 tests the integrity of electrical cables to both identify where trouble exists and which cables or DSX panels are faulty prior to installation and turn up of a high density DS1 or DS3 circuit pack.
Detectable blank circuit packs
DMX supports detectable blank circuit packs: LNW98 in unequipped
Function and Growth slots, LNW97 in an unequipped M2.
The WaveStar
®
CIT reports the presence of a detectable blank in a slot by displaying a blank faceplate graphic instead of an empty slot graphic. No alarms are associated with the insertion or removal of the detectable blank.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
2 - 1 1
Features
In-service Upgrades
............................................................................................................................................................................................................................................................
Overview
This section briefly describes the in-service upgrades supported through Release 7.0 of the Metropolis
®
DMX Access Multiplexer. All features associated with Release 7.0 display the release number next to the feature title. If no release number is specified, the feature was part of a previous release of DMX.
LNW1 to LNW2 in-service upgrade
DMX supports an in-service upgrade from the LNW1 to LNW2 circuit packs on any shelf that is running Release 5.x software. The LNW1 functions with every software Release prior to R6.0, but the LNW2 must be used with R6.0 software (or that of a later Release).
OC-48 UPSR to OC-192
UPSR in-service upgrade
DMX supports an in-service upgrade, enabling you to increase UPSR network capacity from OC-48 to OC-192 without affecting service. No in-service upgrades to the LNW59 are currently supported.
OC-12 UPSR to OC-48
UPSR in-service upgrade
DMX supports an in-service upgrade, enabling you to increase UPSR network capacity from OC-12 to OC-48 (small, 12 STS-1 fabric packs) without affecting service. No in-service upgrades to the LNW59 are currently supported.
OC-48 BLSR to OC-192
BLSR in-service upgrade
DMX supports an in-service upgrade, enabling you to increase BLSR network capacity from OC-48 to OC-192 without affecting service. No in-service upgrades to the LNW59 are currently supported.
In-service electrical upgrade from low to high-density DS1/DS3 circuit packs
DMX supports an in-service electrical upgrade on the High-capacity shelf, enabling you to increase DS1/DS3 capacity without affecting service. There is an outage of 100 to 200 milliseconds when upgrading
DS1 circuit packs. Total DS1 capacity can be increased from 112 to
224 DS1 interfaces per shelf. Total DS3/EC1 capacity can be increased from 48 to 192. Electrical in-service upgrades can be performed on shelves hosting a mix of DS1 and DS3/EC1 circuit packs without affecting service. The DMX High-Capacity shelf is required when using high-density DS1/DS3 circuit packs.
Important!
DMX also supports an in-service electrical upgrade from the LNW16 to the LNW19 or 19B (the LNW19B is available beginning in R5.0). No in-service upgrades to the LNW20 are currently supported.
...........................................................................................................................................................................................................................................................
2 - 1 2
365-372-300
Issue 8.0, September 2006
In-service Upgrades
Features
LNW6/7 Upgrade Rules
Whenever upgrading LNW6 to LNW7 circuit packs, it is necessary to first install an LNW8 circuit pack to ensure that the upgrade is completed without loss of service. The LNW6 and LNW7 are not allowed in a DMX system equipped with LNW59 VLF Mains.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
2 - 1 3
Features
Topologies
............................................................................................................................................................................................................................................................
Overview
This section briefly describes the major topologies supported through
Release 7.0 of the Metropolis
®
DMX Access Multiplexer. All features associated with Release 7.0 display the release number next to the feature title. If no release number is specified, the feature was part of a previous release of the DMX.
High-speed (Network interface) OC-192/48/12
UPSR for STS-n/VT1.5
DMX supports Unidirectional Path Switched Rings (UPSR) at the
STS-n and VT1.5 level. When both Main slots are equipped with
OC-192/48/12 VLF or large VT fabric circuit packs, an STS-1/VT1.5 switching fabric (STS-1, STS-3c, STS-12c, and STS-48c) supports the low-speed interfaces. OC-48/12 medium VT fabric cards, supporting
STS-1, STS-3c, STS-12c, and STS-48c are also available. Each circuit pack establishes both an east-to-west and a west-to-east rotation on the ring. A UPSR ring provides a very valuable and reliable foundation for services protecting against fiber cuts and node failures.
High-speed (Network interface) OC-192/48 BLSR for STS-1/VT1.5
The DMX system supports an OC-192/48 Bidirectional Line Switched
Ring (BLSR). When both Main slots are equipped with OC-192/48
OLIU circuit packs, an STS-1 switch fabric supports the low-speed interfaces (STS-1, STS-3c, STS-12c, and STS-48c). A 2-fiber bidirectional line-switched ring (BLSR) is a self-healing ring configuration in which bidirectional traffic travels over the same set of nodes in each direction. Bidirectional switching makes use of redundant (protection) bandwidth on the bidirectional lines that interconnect the nodes in the ring to provide protection for traffic carried on the working bandwidth. Because the traffic is bidirectional, a single circuit does not necessarily consume bandwidth on every span in the ring. This leaves the spans between other nodes available for additional traffic. Therefore, with distributed switching patterns, a
BLSR can carry more traffic than the same facilities could carry if configured for a unidirectional path-switched ring. In BLSR configurations, the VT switch fabric located in the MAIN packs is used only for Function Unit or Growth Slot hairpins.
DMX supports VT BLSRs on all high speed OC-192 interfaces and on high-speed OC-48 interfaces that have a 48 STS-1 VT fabric (LNW29,
LNW27, LNW32, LNW76, LNW221-259).
...........................................................................................................................................................................................................................................................
2 - 1 4
365-372-300
Issue 8.0, September 2006
Topologies
Features
Multiple BLSRs
DMX supports multiple BLSRs on the low-speed interfaces. Including the MAIN, high-speed interfaces, a total of 4 BLSRs can be supported in R6.0. With the VLF Main LNW59, available in R7.0, DMX can support a total of 5 BLSRs when the shelf is equipped with single-port circuit packs. LNW59 provides 4 OC-192 ports, thereby allowing two,
2-fiber BLSRs on the Main interface. When the LNW62 (R7.0) is equipped in all slots of the shelf, DMX can support a maximum of 16
BLSRs.
True 0x1 (R7.0)
With the introduction of the VLF Main pack (LNW59) in R7.0, DMX allows true 0x1 unprotected circuit packs. That means that any slot can be equipped with any pack (some restrictions apply). For example, an
LNW70 could be used to provide switched Ethernet services in slot A1, while slot A2 could be equipped with another pack, like an LNW62.
Two of the same circuit pack can also populate adjacent slots in the same group, yet certain restrictions apply. For more information on
0x1, including circuit pack/slot equipage restrictions, refer to Chapter
5.
The 0x1 OCn application replaces 0x1Sn functionality when VLF
Mains are used. 0x1Sn will still be supported when the shelf is equipped with non-VLF Mains. 0x1 is only available on the low-speed/tributary packs, not on the Main (M1/M2) interfaces. When all lines on an OCn pack are set to 0x1, the pack becomes unprotected and the companion slot can be equipped with a different pack.
VT Grooming and
Squelching
DMX supports GR-1230 compliant VT grooming and squelching on
OC-48/192 BLSRs. DMX also support the automatic generation of VT squelch maps.
High-speed (Network interface) OC-192/48/12
Linear optical extensions
DMX supports 1+1 protected linear optical extensions. The high-speed linear optical extension may connect the DMX shelf, by way of
OC-12/48/192 network interfaces in the MAIN slots, to an
OC-12/48/192 node. This feature performs true linear switching based on line layer defects.
R6.0 and later Releases support revertive unidirectional and bidirectional 1+1 (as opposed to just non-revertive).
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
2 - 1 5
Topologies
Features
Low-speed UPSRs (for
STS-1 termination and VT
Ring Closure)
The DMX can host multiple rings on the low-speed interfaces of the
DMX shelf. Each circuit pack establishes both an east-to-west and a west-to-east rotation on the ring. A UPSR ring provides a very valuable and reliable foundation for services protecting against fiber cuts and node failures.
DMX supports UPSRs on all lines of all slots equipped with OLIUs.
Low-speed (Tributary interface) Linear optical extensions
DMX supports 1+1 protected linear optical extensions for data transport originating at a data device. The low-speed linear optical extension may connect the DMX shelf, by way of OC-3/12/48 tributary interfaces in the Function and/or Growth slots, to an OC-3, OC-12, as well as an OC-48 node.
Single- and dual-homed ring extensions
The DMX supports low-speed OC-3/12/48 0x1 protected broadband tributaries, including single- and dual- homed ring extensions. A
DDM-2000 OC-3, OC-12, FiberReach, DMXpress, DMXtend, or
DMXplore may be the add/drop multiplexer on the lower-speed ring.
Hairpinning
In “hairpinning” topologies prior to R7.0, low-speed tributary traffic was routed into the system and back out without ever being placed on the high-speed (OC-12, OC-48 or OC-192) interfaces. If the VLF Main pack (LNW59) available in R7.0 is used, all cross-connects use the switch fabric located on these packs. Any switch fabrics located on low-speed, tributary packs are disabled when VLF Mains are used.
Prior to R7.0, and when VLF Mains are not used, DMX is capable of connecting any input on a circuit pack in a function or growth slot to any output on a circuit pack in a different function or growth slot in the same shelf. With the VLF Mains available in R7.0, DMX can cross-connect any input on a circuit pack in a function or growth slot to any output on a circuit pack in the same or different function or growth slot.
...........................................................................................................................................................................................................................................................
2 - 1 6
365-372-300
Issue 8.0, September 2006
Topologies
Features
Dual Ring Interworking
DMX supports UPSR DRI. DMX dual node ring interworking (DRI) cross-connections comply with Telcordia GR-1400 (which refers to
GR-253-CORE) standards. A service selector exists for each STS-N tributary provisioned for DRI.
GbE Private Line
DMX GbE private lines (1000 Mbps) enable premium data transport services offering GbE transport with optional bandwidth provisioning up to full line-rate. GbE private lines provide the user the ability to transport frames completely transparently between two DMX NEs. No
VLAN knowledge or packet-layer provisioning is required by the user in this application. Simple, SONET cross-connect provisioning is all that is required when using “private line” or “no tag” mode. These GbE capabilities allow the DMX to provide dedicated bandwidth for individual customers and fast SONET-layer restoration.
Fast Ethernet Private Line
DMX Fast Ethernet (10/100 Mbps) private lines enable premium data transport services offering 10/100 Mbps transport with optional bandwidth provisioning up to 100Mbps (variable bandwidth provisioning of 1, 2, or 3 STS1s. Fast Ethernet private lines provide the user the ability to transport frames completely transparently between two DMX NEs. No VLAN knowledge or packet-layer provisioning is required by the user in this application. Simple, SONET cross-connect provisioning is all that is required. These Fast Ethernet capabilities allow the DMX to provide dedicated bandwidth for individual customers and fast SONET-layer restoration. LNW71 or LNW74 must be used to enable Fast Ethernet private lines.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
2 - 1 7
Topologies
Features
GbE Packet Rings
DMX supports Gigabit Ethernet (GbE) packet rings that enable cost-effective Internet access and business-to-business LAN services.
GbE packet rings allow interworking among 10/100 Mbps and 1000
Mbps (GbE) Ethernet lines while VLAN tagging ensures individual customer privacy. These GbE capabilities allow the DMX to support various Quality of Service (QoS) features, including fast packet-layer restoration.
4093 VLANs
DMX allows the provisioning of up to 4093 separate IEEE 802.1q
VLANs. VLANs are a way in which LAN users at the enterprise level, located on physically separated LAN networks, are assigned priority access privileges across a WAN backbone. Although they are in different locations, they appear to be on the same physical segment of an enterprise-level LAN. Thus, VLANs are logical groupings of various users, regardless of their physical location on the network.
Stacked VLANs (VLAN Transparency)
DMX allows customer traffic to be identified and segregated using
“stacked” IEEE 802.1q VLAN tags. VLAN tags enable the formation of Virtual Private Networks (VPNs) by segregating various units of traffic and isolating different end-customers. This allows data from different customers to efficiently share common bandwidth while simultaneously ensuring a basic level of security for each customer
(hence VPN).
The notion of VLAN “transparency” comes from the fact that individual customer packets are tagged using a second tag, a default port tag (default port tag is provided by customer equipment). There is no need to coordinate VLAN tags between the customer and service provider. Therefore, customer packets are transmitted through a service provider’s network “transparently”.
...........................................................................................................................................................................................................................................................
2 - 1 8
365-372-300
Issue 8.0, September 2006
Topologies
Features
Resilient Packet Ring
(RPR) Ethernet Protection
DMX supports Resilient Packet Ring (RPR) Ethernet transport compliant with IEEE 802.17. RPR is intended to optimize
Ethernet-based metro ring networks for packet transport with resiliency equivalent to that of SONET rings. It could be used to carry voice and
TDM traffic with the QoS of SONET and ATM combined, while supporting LAN traffic with the efficiency of Ethernet. It also employs a fairness algorithm to allow equal access to opportunistic bandwidth regardless of a node’s position around the ring.
DMX’s RPR implementation uses enhanced Ethernet bridging as opposed to basic Ethernet bridging. Basic bridging may be supported in a future release.
RPR is supported through the use of the LNW78. LNW78 supports one
RPR instance in R7.0 and two in the future. The LNW78 provides two internal Virtual Concatenation Group (VCG) WAN ports (will support
4 in the future) with a total capacity of 2.5 Gbps capacity for Ethernet
RPR traffic.
Dense Wave Division
Multiplexing (DWDM)
DMX supports DWDM on OC-48 high-speed and low-speed and
OC-192 high-speed interfaces. DWDM enables you to combine multiple OC-48/192 wavelengths on the same fiber. With DWDM and passive filter components, fiber capacity can be increased by a factor as great as 32.
Non-preemptable
Unprotected Traffic
DMX allows the manual provisioning of non-preemptable unprotected traffic (NUT). NUT can be used on both high-speed and low-speed
BLSRs.
NUT ensures that data transmission over SONET BLSR topologies runs smoothly. When using multi-point cross-connections through a
BLSR, packets do not receive standard BLSR protection due to the necessary functioning of NUT. Yet, protection on all data packets is provided for with rapid spanning tree protocol (IEEE 802.1w). Thus,
NUT enables protected packet rings without utilizing SONET layer protection.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
2 - 1 9
Features
Networking Capabilities
............................................................................................................................................................................................................................................................
Overview
This section briefly describes the major networking capabilities supported through Release 7.0 of the Metropolis
®
DMX Access
Multiplexer. All features associated with Release 7.0 display the release number next to the feature title. If no release number is specified, the feature was part of a previous release of the DMX.
1+1 Non-revertive
Bidirectional Protection
Switching
DMX now supports non-revertive bidirectional protection switching for all OC-n interfaces in addition to non-revertive unidirectional protection switching.
1+1 revertive unidirectional and bidirectional
Protection Switching
R6.0 and later Releases support revertive unidirectional and bidirectional protection switching.
SAN Networking via DMX
With the LNW73 DMX supports native SAN interfaces integrated into the DMX shelf. The LNW73 is a Storage Area Networking (SAN) interface card designed to facilitate SAN distance extensions via the use of GFP-T (G.7041) to encapsulate SAN traffic and transport it over
SONET networks. It utilizes PTM optics to provide the option of
FICON, ESCON, or Fibre-channel interfaces natively on the DMX shelf. Each pack must be equipped with only one type of PTM (either
FICON/FC or ESCON) and can be housed in Slot A1, B1, C1, D1, or
G1. The LNW73 can operate at 1 Gbps or 2 Gbps. When the pack is operating at 2 Gbps only every other port may be used. So, the total number of SAN interfaces on a DMX shelf is 20 when the LNW73 is operating at 1G FC/FICON or ESCON, and 10 when it is set to 2G
FC/FICON.
DMX is pursuing interoperability certification with established storage hardware vendors such as IBM and EMC. Interoperability testing is currently underway with EMC, with a target date of the end of 2006.
To achieve EMC certification, DMX has been tested with various
FC/FICON switches used with EMC storage equipment. Presently,
DMX has completed testing with the Brocade Silkworm 3800 and
2250, the McData Sphereon 4500, and Cisco MDS 9120 and MDS
9126. This testing has yielded some simple guidelines that need to be followed to ensure smooth interworking between DMX and the
FC/FICON switches listed above. For more information on these
...........................................................................................................................................................................................................................................................
2 - 2 0
365-372-300
Issue 8.0, September 2006
Networking Capabilities
Features
Data Compression for SAN
Traffic (R7.0)
The R7.0 implementation of SAN compression enables a high throughput of up to two full-line rate FC-2G interfaces in a single pack.
Release 7.0 supports data compression on new LNW73C SAN packs.
The LNW73C is able to compress asychronous Fibre Channel traffic and conserve up to 50% of bandwidth versus uncompressed asynchronous FC traffic in typical applications.
Compression for asynchronous FC traffic is pre-standard and will be standardized by FC-BB-4.
Ethernet Interworking with
DDM-2000
To facilitate affordable and more immediate delivery of Ethernet services on SONET networks, DMX now interworks with new
Ethernet circuit packs available for the DDM-2000.
DDM-2000 now supports a circuit pack providing one 100BASE-LX
(100 Mbps p/s) and four 10/100 BASE-TX ports with data transport at the rate of 10/100 Mbps using standard Ethernet switching (IEEE
802.1), standard encapsulation according to ITU G.7041 for Generic
Framing Procedure (GFP), ITU G.707 for Virtual Concatenation
(VCAT). The DDM-2000 can transmit Ethernet signals across spans as long as 100 meters. The DDM-2000 circuit pack is designed specifically to support Fast Ethernet Private Line applications. Each circuit pack can support 4 private lines. The pack supports VT1.5,
STS-1, and STS-3c cross-connections.
The DDM-2000 circuit pack can interwork with the LNW71 and
LNW74 circuit packs.
1 Mbps Rate Limiting
DMX supports rate shaping at the level of 1 Mbps for Ethernet interfaces. This means that DMX can automatically establish Ethernet transmission channels to fit the need of the user upon connection. For each connection, the DMX will create a virtual channel of the appropriate size (in 1 Mbps intervals) to facilitate the desired Service
Level Agreement (SLA). Rate limiting at the 1Mbps level provides a transmission ceiling for highly efficient allocation of shared bandwidth for data communications.
High-speed VT1.5
granularity
VT1.5 granularity is provided across any 12 STS-1 signals within the
OC-48 OLIU (LNW26B, LNW77, LNW28, and LNW121B-159B) providing a fully-flexible assignment of VT1.5 timeslots across any 12
STS-1s. VT1.5 granularity is provided across 48 STS-1 signals within the OC-48 OLIUs (LNW27, LNW29, LNW32, LNW76, and
LNW221-259). VT1.5 granularity is provided across 48 STS-1 signals within the OC-192 OLIUs (LNW58, LNW56, LNW57, LNW523,
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
2 - 2 1
Networking Capabilities
Features
LNW527, LNW554, and LNW555). The LNW59 boasts a 40G VT fabric.
VT1.5 granularity is provided across 96 STS-1s on the LNW80 (Main
Switch Pack).
For the VT granularity of the tributary (low-speed) packs, refer to the section above entitled
Optical, Tributary Interface Circuit Packs
.
Automatic Ring Discovery for BLSR Interworking
DMX supports automatic ring discovery to better facilitate BLSR interworking with Lucent’s FT-2000, WaveStar BandWidth Manager,
Lambda Unite, and WaveStar 2.5G/10G.
Non-preemptable
Unprotected Traffic
DMX allows the manual provisioning of non-preemptable unprotected traffic (NUT) for multi-point Ethernet and 0x1 cross-connections on service tributaries. Though this traffic is unprotected, its transmission priority will not be preempted by other service or protection traffic.
DMX/Lambda UNITE bay configuration
The compact size of the DMX allows you to place two DMX shelves and one Lambda UNITE in the same bay. As the needs of an access site grow to the point where equipment is required to hub more than 6
OC-48 rings, it becomes advantageous to upgrade a DMX shelf to a
Lambda UNITE. The Short Reach (SR) OC-48 and OC-192 optics supported by the DMX are designed for such an application. Once the
Lambda UNITE is installed as the hub-node, the Unite node can hub 64
OC-48 rings or 16 OC-192 rings while simultaneously using the original DMX as a drop node or mini-DCS.
Multicast Ethernet Packets
DMX supports multicast Ethernet packets in all releases. A multicast packet is identified by the first bit in the MAC destination address.
Such a MAC address will never appear as a source address, and so multicast destination addresses (TIDs) are not learned. Since unknown source addresses a treated as broadcast, multicast packets/frames are sent to ALL ports in the VLAN (IEEE 802.1Q) or Transparent LAN
(customer/port tag) for that packet.
Optical Terminal and
Facility Loopbacks
DMX supports facility loopbacks on all OC-192/48/12 high speed
(network side) interfaces. DMX also supports OC-3/12/48 low speed
(tributary side) facility loopbacks as well as low speed OC-3/12/48 terminal loopbacks. Terminal and facility loopbacks are used for installation and maintenance procedures to test the integrity of near and far- end interfaces as well as fibers and system circuitry. OC-3 facility loopbacks are only supported on the LNW37/45 circuit packs.
...........................................................................................................................................................................................................................................................
2 - 2 2
365-372-300
Issue 8.0, September 2006
Networking Capabilities
Features
DS3 Terminal Loopbacks
DMX supports terminal loopbacks on DS3 interfaces.
Ethernet Terminal
Loopbacks
DMX supports terminal loopbacks on all Ethernet interfaces. Ethernet loopbacks may be used during installation and maintenance procedures to test the integrity of near and far- end interfaces as well as fibers and system circuitry.
Ethernet Facility
Loopbacks (R7.0)
DMX supports facility loopbacks on the LNW70 and LNW78. Facility loopbacks are used to test the integrity of the customer to provider network link by looping the signals back at the far end and comparing counts of sent and received frames.
Facility loopbacks are supported on both individual ports and Link
Aggregation Groups (LAGs). Loopbacks on LAGs are permitted simultaneously for both ports in the group because they are treated as failed members allowing transmission on unlooped members. If a facility loopback is set up on a LAG, alarms are suppressed on both the member ports and the LAG.
MAC Address Locking
(R7.0)
DMX allows MAC locking on the LNW70. MAC locking prevents unauthorized users from gaining access to the network through an
Ethernet port, thereby providing a level of security against intrusion attempts. MAC locking restricts access to a bridged Ethernet network by requiring that the source address of traffic entering a locked port be registered with that port. Any number of ports, LANs, VCG, or link aggregation groups (LAGs) can be locked. DMX permits registering of multiple addresses with a single entity.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
2 - 2 3
Networking Capabilities
Features
Fast Spanning Tree/
IEEE802.1w Rapid
Reconfiguration
Ethernet requires a network with a tree structure in order to work effectively. Ethernet bridges and switches build tables that define the paths to specific devices. A MAC bridge, for example, will have a filtering database that defines where to send any packets addressed to a specific MAC within the network. The tables are built based on input from devices within the network. DMX supports an improved/faster spanning tree algorithm, documented in IEEE 802.1w Rapid
Reconfiguration.
R6.0 added support of spanning tree on LAN ports on the LNW70 in addition to VCG ports that were supported in previous releases.
If there is a loop in the network, that is, if there is more than one way to get to a destination device, two problems can result:
Frames may be duplicated in the network.
• That is, the same frame may be sent to a node via two different paths.
The address information will be changed as packets from that device are received across different paths. In a meshed network, the reconfiguration of the filtering database can begin to use up all the network resources, so that little bandwidth is left for data traffic.
The spanning tree accomplishes two important functions:
• It removes loops from the bridged network
• It allows Ethernet layer reconfiguration if a link fails.
Important!
DMX has been designed with multi-vendor interoperability in mind. As many vendors’ equipment (including legacy equipment) may not be able to use IEEE802.1w, DMX can automatically fall back on IEEE802.1d in the event that other NEs in the network are running standard spanning tree protocol.
However DMX employs IEEE 802.1w as a default spanning tree protocol.
SS Bits Per Pack
By default DMX transmits 00 in the outgoing SS pointer bits for compatibility with SONET interfaces. DMX provides the ability to set the outgoing SS bits to 10 on a LS optical pack basis for compatibility with older SDH equipment. DMX ignores incoming SS bits regardless of the outgoing SS bit provisioning. Most SONET equipment ignores
SS bits. DMX is provisionable to support SS bits on a per pack basis.
This prevents LOP defects and allows SONET/SDH interworking.
...........................................................................................................................................................................................................................................................
2 - 2 4
365-372-300
Issue 8.0, September 2006
Networking Capabilities
Features
E1 Service Support
DMX supports 56 E1 signals on the LNW8 circuit pack. E1 signals are
SDH/PDH signals at 2.048 Mbps. DMX supports performance monitoring on E1 signals.
R4.0 Ethernet
Enhancements
Release 4.0 contains many software-based enhancements to the functionality of DMX Ethernet circuit packs. Again, these are software-based enhancements and require no changes to DMX hardware.
• Ethernet Latency improvements
• Ethernet auto-negotiation provisioning
• Automatic MDI/MDIX crossover capability on LNW71
• TCAs on Ethernet PM error counts
• Ethernet MAC address table search and report (with support for static entries)
• Ethernet loopbacks
• Admin-down capability for Ethernet ports
• QinQ stacked VLAN tags
• Extension of 1-way cross-connections for video broadcast to
BLSR rings
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
2 - 2 5
Networking Capabilities
Features
R5.0/5.1 Ethernet
Enhancements
Release 5.0 and 5.1 contain many hardware and software-based enhancements to the functionality of DMX Ethernet circuit packs. As these are hardware-based enhancements, they require the use of the
LNW70 and LNW74 circuit packs. The features with a circuit pack listed in parenthesis are available only with the use of that pack and not both. The features associated with the LNW70 circuit pack are available beginning in R5.1.
• Committed and Peak rate controls (CIR and PIR) (LNW70)
• 4 classes of services (LNW70)
• 4xGbE density with PTM optics (LNW70)
• Larger MAC tables (LNW70)
• 32 VCGs (star configuration) per G.707 (LNW70)
• 16 virtual switches with independent VLAN space per virtual switch (LNW70)
•
Jumbo Frames (refer to Packet size in different tagging modes (A-86)
• Link Capacity Adjustment Scheme (LCAS) per ITU G.7042
• Generic Framing Procedure (GFP) per ITU G.7041
• Client Signal Fail
• 100BASE-FX optical, fast Ethernet ports
• VT1.5 VCAT (LNW74 only)
LNW78 RPR
Enhancements (R7.0)
In addition to the various Ethernet networking capabilities detailed above for R7.0, the LNW78 RPR pack has been upgrades to support the following capabilities:
• VCG ports 17-22 are now available to provide EoS connectivity.
This feature allows EoS port connectivity to RPR ring interfaces via the faceplate of the LNW78 and/or hairpin cross-connects.
• Standards-based LCAS
• Interconnection of multiple RPR rings on the same shelf or separate shelf using EoS VCGs.
• EoS traffic can be managed with QoS support on EoS VCGs.
• Support of Basic RPR Bridging. In past Releases, DMX only supported enhanced RPR bridging.
...........................................................................................................................................................................................................................................................
2 - 2 6
365-372-300
Issue 8.0, September 2006
Networking Capabilities
Features
QoS on EoS VCGs (R7.0)
Quality of service (QoS) on Ethernet over SONET (EoS) VCGs is designed to enable aggregation of diverse data streams in multiple topologies amongst LNW70 and LNW78 circuit packs. These topologies include packet rings, hub-and-spoke with LNW70 at the hub, and hybrid ring/hub-and-spoke with LNW70/LNW78 at the hub.
QoS on EoS VCGs functions by giving EoS VCG ports the same classification options for incoming packets, rate control capabilities for
Ethernet services (PIR, CIR), queuing/scheduling capabilities for outgoing, and the same packet transformation functions as on 802.3
LAN ports.
Link Aggregation on
LNW70 LAN Ports (R7.0)
DMX supports link aggregation on any two LNW70 LAN ports of the same rate (i.e. 100 or 100 Mbps) operating in switched mode. The ports must be located on the same pack and DMX supports a maximum of 8
Link Aggregation Groups (LAGs) per function unit/growth group.
Link aggregation can be used to enable hitless bandwidth increases and both facility and equipment protection on LNW70 LAN ports.
Ordinarily, multiple Ethernet links between two bridges form loops
(unless a spanning tree blocks all but one) so they can’t be used to increase bandwidth. Link Aggregation causes defined groups of links to be treated as a single logical link, making multiple LAN ports appear as one. In this way, Bandwidth can be increased without requiring an upgrade to a higher rate link.
Link aggregation can also remove failed links automatically, thereby providing a means of facility protection. More links than are needed can be added to the group and each is active until it fails (similar to utilizing LCAS protection for SONET).
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
2 - 2 7
Features
Cross-connection Types
............................................................................................................................................................................................................................................................
All allowable crossconnections
This section details the types of cross-connections supported by the last few releases of DMX. Thus, this represents only a fraction of the total allowable cross-connections. For an in depth look at cross-connections supported by the DMX, refer to the section entitled
“Cross-connections” in Chapter 5 of this document.
Atomic cross-connections
Beginning in R6.0, DMX employs atomic cross-connections for all cross-connect provisioning. The introduction of atomic cross-connections simplifies cross-connection provisioning and lays the ground work for the support of additional applications and combinations of cross-connections in future releases. Atomic cross-connections are one-way cross-connections between logical ring channels which can be set up and taken down by a single command, and which cannot be broken down into smaller parts. Logical ring channels are the tributaries of a port or port protection group used for transmission in the absence of any line or equipment protection.
Atomic cross-connections are more flexible than the cross-connect provisioning structure employed previously. They allow for the support of more detailed applications because multiple atomic cross-connections can be provisioned to construct the desired cross-connection application.
The difference is that you are provisioning each portion of the 2way cross-connect (as in legacy releases) as 1way cross-connects. This provides increased flexibility in provisioning all cross-connects.
For customers who use the WaveStar PC-CIT, Telcordia Operating
Systems (OS), and Navis INC this change will be transparent. In order to support atomic cross-connections for the first time, customers employing proprietary OS solutions will need to adjust their cross-connection provisioning procedures.
...........................................................................................................................................................................................................................................................
2 - 2 8
365-372-300
Issue 8.0, September 2006
Cross-connection Types
Features
Hairpinning cross-connections
In “hairpinning” topologies prior to R7.0, low-speed tributary traffic was routed into the system and back out without ever being placed on the high-speed (OC-12, OC-48 or OC-192) interfaces. If the VLF Main pack (LNW59) available in R7.0 is used, all cross-connects use the switch fabric located on these packs. Any switch fabrics located on low-speed, tributary packs are disabled when VLF Mains are used.
Prior to R7.0, and when VLF Mains are not used, DMX is capable of connecting any input on a circuit pack in a function or growth slot to any output on a circuit pack in a different function or growth slot in the same shelf. With the VLF Mains available in R7.0, DMX can cross-connect any input on a circuit pack in a function or growth slot to any output on a circuit pack in the same or different function or growth slot. This is because R7.0 enables true 0x1 configurations where both slots in a function group can be provisioned independently for working traffic, wether they are the same or different packs (certain restrictions
apply, refer to Very Large Fabric (VLF) Engineering Rules (5-15)).
These flexible cross-connect capabilities allow you to use a combination of add/drop and hairpinning of compatible payloads through a variety of interfaces. You can bring traffic in from one remote site and cross-connect it at the VT1.5, STS-1, STS-3c, STS-12c, or STS-48c level back out to other remote sites without consuming any capacity on the ring/line interface.
If hairpinning cross-connections are being provisioned between any interface and a 0x1 unprotected interface, 1-way cross-connections must be used. 1-waypr cross-connections are not allowed in 0x1 unprotected scenarios.
Bridge and Roll cross-connections
Bridge and roll cross-connections are coordinated activity between two
NEs designed to move traffic from one facility to another, affecting service by a maximum of 10 milliseconds.
Bridged Cross-connections
Bridging of an existing cross-connection consists of adding a one-way cross-connection with the same input tributary as that of an existing cross-connection, resulting in a 1x2 multicast from an input tributary to two output tributaries. DMX supports bridging for each of the supported SONET cross-connection rates. You can bridge any existing cross-connection to a second output port without impairing the existing signal. Conversely, either half of a bridged signal can be taken down without impairing the remaining cross-connected signal.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
2 - 2 9
Cross-connection Types
Features
Rolling a bridged cross-connection
The DMX provides the capability to change the location or source of the input tributary of a given cross-connection. The DMX supports facility rolling for all supported signal rates as follows:
• Disconnection of the circuit cross-connecting input tributary to output tributary
• Cross-connection of either a new input tributary to the corresponding input tributary
Locked DS1/DS3 Cross
Connections
In the “locked” mode, DMX does not select the best signal from both rotations of a UPSR. Instead, traffic is added and dropped (locked) from one rotation of the ring only (provisionable). The main advantage of locked DS1/DS3 cross-connections is the lack of UPSR switching.
Locked VT Cross
Connections (R7.0)
In the “locked” mode, DMX does not select the best signal from both rotations of a UPSR. Instead, traffic is added and dropped (locked) from one rotation of the ring only (provisionable). The main advantage of locked VT cross-connections is the lack of UPSR switching which results in the ability to reuse timeslots around a UPSR.
The ability to mix locked, unlocked, and pass-through VT1.5s within the same STS-1 was added in R6.0.2. In R7.0, DMX also allows both rotations of a ring to be used simultaneously.
Linear/Unprotected UPSR
(R7.0)
In R7.0, DMX also allows both rotations of a ring to be used simultaneously. Prior to 7.0, if a 1WAY (as opposed to a path-protected
1WAYPR) cross-connection was established with the source from a
UPSR ring, the other side became unusable as the source (1WAY) or destination of a cross-connection (1WAY or 1WAYPR), except for pass-through cross-connections. This feature removes those restrictions.
DMX permits simultaneous 1WAY cross-connections sourced from the
2 associated ring channels in a UPSR application, simultaneous 1WAY cross-connection sourced from a ring channel, and 1WAY or
1WAYPR destined to the associated ring channel.
This feature removes the need for unswitched cross-connections on
Ethernet/Data packs which don’t require VCG pairing, yet they will still be supported to ensure backwards compatibility.
...........................................................................................................................................................................................................................................................
2 - 3 0
365-372-300
Issue 8.0, September 2006
Features
Operations Features
............................................................................................................................................................................................................................................................
Overview
This section details the operations features available with Release 7.0 of the Metropolis
®
DMX Access Multiplexer. All features associated with Release 7.0 display the release number next to the feature title. If no release number is specified, the feature was part of a previous release of the DMX.
DMX PC-CIT with GUI
The PC-CIT manages the DMX system through the TL1/CIT port, providing TL1 messaging, software download, and full operations and provisioning capability via a Graphic User Interface (GUI) or TL1 command builder. The PC-CIT can run a full-featured GUI or TL1 scripts. Using the GUI, a crafts person can access all DMX software functions and context-sensitive help. The TL1 command builder, also known as the TL1 Translation Device (T-TD), is a flexible TL1 command instructor that supports full TL1 management through
TCP/IP or RS-232 interfaces.
The PC-CIT is not used to download release software to the system (the
PC is used, but not the CIT software). Release software can be copied to other NEs remotely, provided the initial download of DMX release software has occurred on each system.
Performance monitoring
Performance monitoring (PM) data will be reported on the VT1.5,
VC12, STS-1, STS-3c, STS-12c, STS-48c, DS1, E1, DS3, EC-1,
Ethernet (LAN and VCG ports), SAN, OC-3, OC-12, OC-48 and
OC-192 levels.
Alarm Severity Assignment
Profiles (ASAPs)
DMX supports adjustable ASAPs. With ASAPs, alarms are grouped into categories called “Profile Types”. Each Profile Type can have multiple views (ASAPs). These views include the default view and various user created/provisioned profiles. Each ASAP within a profile type has the same alarms, but alarm severity levels are user provisionable. The user can then assign ASAPs to entities within the shelf.
With legacy releases, many alarm severity levels are hardcoded and are not adjustable. R6.0 and later Releases make it possible to assign different alarm severity levels for all alarms. This feature also allows the user to assign different alarm severity levels for the same probable cause to different entities within the shelf. Once alarm severity levels
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
2 - 3 1
Operations Features
Features
Pipe-mode (adaptive-rate) cross-connections
Proxy ARP
are set, the user can assign the same level to different entities without reprovisioning the level itself.
These capabilities give the user greater control over alarm reporting.
Pipe mode is a fault and PM feature whereby fault and PM are reported independently for each constituent signal within a cross-connection rather than simply at the xc rate.
In normal ARP usage for an Ethernet LAN, the sending system broadcasts an ARP request on the physical LAN. The ARP request contains the target IP address and asks the system with this IP address to respond with its physical Ethernet address. All systems on the LAN receive the request, but only the system which recognizes the target IP address as its own will send a point-to-point ARP reply to the sending system. The broadcast ARP request on a physical LAN only reaches systems which are attached to this physical LAN. If the sending system and the target system are on different physical networks, the target system will not receive the ARP request and thus can not respond to it.
Proxy ARP lets a system, called ARP subnet gateway, answer ARP requests received from one of its physical (LAN) networks for a target system which is not attached to this physical network.
To allow SNMP manager/NTP server located in the IP-based access
Data Communication Network (DCN) to communicate with NEs located in the OSI-based DCN, DMX supports IP tunneling solution to encapsulate and route IP packets over OSI-based embedded DCN. The provisioning of static routes on the external router(s) is required to route the IP packets from the access DCN to the embedded DCN. The
Proxy ARP support on the Gateway Network Element (GNE) will eliminate this need of static routes on the external router(s).
Support of Simple Network
Management Protocol
DMX makes use of Simple Network Management Protocol (SNMP).
SNMP is the most common protocol used by data network management applications to query a management agent using a supported Management Information Base (MIB). SNMP operates at the
OSI Application layer. The IP-based SNMP is the basis of most network management software, to the extent that today the phrase
“managed device” implies SNMP compliance. The DMX provides
SNMP support of certain reports and traps for all Ethernet interfaces.
For more information, see the section entitled “SNMP Parameters and
Traps” in Chapter 6 of this document.
DMX supports SNMP on DS1/E1 and DS3/EC-1 interfaces. SNMP support of these TDM interfaces includes traps and performance monitoring parameters.
...........................................................................................................................................................................................................................................................
2 - 3 2
365-372-300
Issue 8.0, September 2006
Operations Features
Features
Test Access
Test access, a traditional DCS function, allows the user visibility into any DS1/DS3 signal in the network. Test access aids users in turning up connections and in identifying faults in existing service connections.
DMX supports two different types of test access. The non-intrusive method simply taps the DS1 channel as it passes through the system and routes it to an external testing device. The more intrusive mode splits the DS1 or DS3 from the incoming signal and sends it to an external testing device. Test access facilitates DMX functioning in a
DCS application.
PRBS generation/detection
Test access using PRBS generation/detection via the internal test head on the VLF Main allows the user to test network, NE, and facility performance/integrity without an external test head. The VLF Mains introduced in R7.0 contain an internal test head that can generate and detect errors in Pseudo Random Bit Sequences (PRBSs). This capability is not meant to wholly eliminate the use of external equipment for tests, but can be used for expediency, less complicated tests, and where non-manual set-up is advantageous. PRBS enabled test access involves initiating test access, inserting a test signal (i.e. a
PRBS) generated internal to the NE, and/or monitoring a received test signal internal to the NE. PRBS generation/detection is supported on
STS1 and STS3c tributaries.
DMX allows up to 12 test access sessions at a time and for a mix of the old style test access sessions described on the previous pages
(specifying tatrib(s)) or the new-style session (to the internal test head) within the 12 allowed sessions. The internal test head hardware supports signal generation on up to 12 STS1s, and signal detection on up to 12 STS1s. Test access for STS3c rates is new in R7.0. Only internal test access is supported on STS3c signals; requests using the tatrib parameter(s) will be denied. It’s important to note that when a generator or detector is allocated to an STS3c session, it uses 3 of the
12-STS1 capacity, and that 3 generators or detectors on the STS3c boundary must be available.
TL1 management
TL1 messaging is supported via the Serial and IAO LAN interfaces.
The DMX PC-CIT, when used in conjunction with the TL1 command builder, provides full TL1 management through TCP/IP to OSI interfaces.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
2 - 3 3
Operations Features
Features
TL1 management via
TCP/IP
TL1 message exchange is supported over TCP/IP via IAO LAN, OSI
LAN, and PC-CIT interfaces. IAO LAN supports TCP/IP protocol and
OSI protocol. These provide a communication link from a DMX to a local node that may serve as a gateway to the network.
Integrated TCP/IP
Management Interface
The DMX supports two types of IP Access. In one case, the DMX can serve as a TL1 Translation Device (T-TD) by being a gateway network element that allows a Navis EMS and/or PC-CIT to communicate to other network elements (NEs) on an OSI network through an IP access network. In the second instance, the DMX can functionally encapsulate
IP packets within OSI packets to be transmitted through the OSI network to the proper NE. This capability is called IP tunneling.
TL1 Translation
The DMX can copy the application information within an IP packet into an OSI packet. Thus, all IP protocol information is lost. This translation is performed at the application layer. Separate gateways can be provided by a single DMX.
IP Tunneling
IP tunneling allows for file transfer through an IP access network. IP tunneling is used to perform end-to-end FTP through the OSI portion of the IP access network. In this instance the DMX serves as a gateway network element (GNE) that encapsulates an IP packet within an OSI packet. When the final destination of the file is reached, the IP packet is removed from within the OSI packet and processed by the TCP/IP stack. Thus, IP tunneling allows an Navis EMS and/or CIT to reach
NEs in an OSI based DCN network with FTP over IP. In this case, the end points of the IP tunnel are the actual terminating points for the IP traffic.
FTP/FTAM Gateway for remote software download
Also referred to as FTTD (File Transfer Translation Device), the FTTD allows DMX to function as a Gateway Network Element (GNE) that can facilitate the download of files located at FTP servers to remote
NEs connected to the DMX.
Software download over
DCC
This feature enables software (upgrade) to be downloaded to remote
NEs from a central office site via the data communications channel
(DCC).
...........................................................................................................................................................................................................................................................
2 - 3 4
365-372-300
Issue 8.0, September 2006
Operations Features
Features
Increased OSI associations
The maximum number of OSI associations per TCP connection has been increased from 64 to 300. The maximum number of OSI associations for TL1 per GNE has been increased from 200 to 300.
250 NEs in a Level 1 area
The maximum number of NEs per OSI Level 1 routing area has been increased from 50 to 250.
OSI seven-layer protocol stack
This feature provides interworking using the Open Systems
Interconnection (OSI) seven-layer protocol stack over the data communications channel (DCC). The OSI seven-layer protocol stack refers to the OSI reference model, a logical structure for network operations standardized by the International Standards Organization
(ISO).
Remote NE Status
This feature partitions a subnetwork into maintenance domains (alarm groups). An Alarm Group is a set of NEs that share status information.
Alarm groups can be nodes in a ring or any other logical grouping such as a maintenance or geographical group. Each Level 1 area can be identified as a separate Alarm Group, as long as it does not exceed 50 nodes. You must provision one NE in an Alarm Group as an alarm gateway NE (AGNE) to support office alarms and a summary alarm information of remote NEs in the local alarm report. More than one
AGNE can be provisioned per alarm group, but this is not recommended.
Security
Security features include 1-999 day password aging, customized login proprietary messages, and 150 users.
TARP
DMX is compatible with any other-vendor NEs that support Target ID
Address Resolution Protocol (TARP), OSI, IAO LAN, and TL1 as specified in Telcordia Technologies GR-253.
SONET
Many of the traditional SONET maintenance, provisioning, operations, control, and synchronization features are included in the DMX. The flexible SONET standard provides a formidable foundation for the
DMX to build upon.
TIRKS/NMA/Transport compatibility
Multivendor Operations
Interworking
DMX is supported by Telcordia OSs: TIRKS, NMA, and Transport.
DMX supports interoperability with many vendors’ equipment.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
2 - 3 5
Operations Features
Features
Product Family
2000/WaveStar Product
Family Interworking
DMX supports TARP interoperability with Product Family 2000 nodes such as the FT-2000 OC-48 Lightwave System, the DDM-2000
OC-3/OC-12 Multiplexer, and the DDM-2000 FiberReach Multiplexer.
DMX also provides interoperability with all WaveStar Product Family nodes supporting TARP over both UPSR and BLSR applications.
DMX provides interoperability with WaveStar BandWidth Manager nodes supporting TARP over both OC-48 and OC-192 BLSRs.
Navis
®
Operations Support
DMX supports operations via Lucent’s Navis™ Optical OMS and
Navis™ Optical INC.
Network Time Protocol
Network Time Protocol (NTP) assures accurate synchronization of the
DMX with reference to radio and/or atomic clocks located on the
Internet.
...........................................................................................................................................................................................................................................................
2 - 3 6
365-372-300
Issue 8.0, September 2006
Features
Synchronization
............................................................................................................................................................................................................................................................
Embedded Stratum 3 timing generator
The OC-12/48/192 high-speed circuit packs (as well as LNW80) contain an embedded Stratum 3 timing generator. This timing generator is used when the DMX is configured in a free running mode.
Line timing and external timing are also supported by DMX. Line timing is derived from an incoming MAIN or tributary OC-12/48/192 line, while external timing is derived from an external timing source.
Line timing from tributary optical interfaces is supported beginning in
R7.0.
DS1 timing output
DMX can generate a DS1 timing output to time other externally-timed systems. The DS1 output is derived from a line reference.
S1 byte synchronization messaging
DMX uses the S1 byte of the SONET overhead to pass timing status information to different nodes in an access transport network.
Line Timing from Optical
Tributary Packs (R7.0)
DMX can derive timing references from low-speed/tributary optical interfaces beginning in R7.0. Prior to R7.0, line timing references could only be derived from the signals entering the Main circuit packs. DMX can now derive timing references form any optical line entering Main,
Function Unit, or Growth slots.
All optical circuit packs can derive a 6.48MHz timing signal from an incoming optical line.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
2 - 3 7
Synchronization
Features
...........................................................................................................................................................................................................................................................
2 - 3 8
365-372-300
Issue 8.0, September 2006
3 Applications and Configurations
Overview
............................................................................................................................................................................................................................................................
Purpose
The DMX Access Multiplexer supports a wide range of service applications and a variety of network configurations economically and efficiently.
Because DMX is very flexible, most of the applications described in this section can be served over many of the available network topologies. The product configuration deployed depends on many factors such as fiber layout location, mix of services offered, and interconnections to other networks.
The first section of this chapter describes service applications. The second section explains the network topologies supported.
The following sections are included in this chapter:
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
Lucent Technologies – Proprietary
See notice on first page
3 - 1
Applications and Configurations
Service Applications
Overview
............................................................................................................................................................................................................................................................
Purpose
The DMX Access Multiplexer provides a wide range of service applications transporting voice and data from the access edge of the network to the core of the network. These applications range from traditional SONET applications to advanced data transport applications.
Features
DMX provides the following features for the service applications described in this section:
• DS1 transport and switching
• DS3 transport and switching
• E1 transport
• EC-1 transport and switching
• OC-3 transport and switching
• OC-12 transport and switching
• OC-48 transport and switching
• OC-192 transport and switching
• 100BASE-TX/FX transport and switching
• 1000BASE-SX/LX transport and switching
• SAN (FICON/ESCON/Fibre-Channel) transport
• Synchronization distribution (DS1 timing inputs and outputs)
• Single-ended or independent operations
• Long reach single-mode fiber spans for OC-3, OC-12, OC-48, and
OC-192 optics
• Passive wavelength division multiplexing (DWDM)-compatible optics.
...........................................................................................................................................................................................................................................................
3 - 2
Lucent Technologies – Proprietary
See notice on first page
365-372-300
Issue 8.0 September 2006
Overview
Applications and Configurations
The figure below shows how the DMX fits into Lucent’s metropolitan optical networking solution.
Figure 3-1 Multiservice Optical Access Network
Large
Business
PBX/Switch
Router
- Voice
- Broadband Data
- 100/1000 Ethernet
Metropolis
DMX
®
DOS
Metropolis
®
DMX
OC-48/192 UPSR
Metropolis
®
DMX
Medium
Business
Switch
Router
OC-48
U
Metropolis
®
DMX
PSR
Metropolis
®
DMX
FR/ATM
Edge
Switches
Broadband
(ATM,TDM)
Ethernet
DSLAM CMTS
- Voice
- Wideband Data (TDM,
ATM, FR,PPP)
- 10/100 Ethernet xDSL
Residential/SOHO
Customer
ATM
Concentrator
Access Node
®
DMX = Metropolis DMX Access Multiplexer
HFC
Voice
Switch
Access
Routers
LAN
Application
Services
Core
Router(s)
Access
Routers
ATM
Core
Switch
Service Node/CO
PSTN
Internet
ATM nc-dmx2-029
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
Lucent Technologies – Proprietary
See notice on first page
3 - 3
Overview
Applications and Configurations
Contents
Service applications described in this section include:
Access Transport for Voice and TDM Private Line Services
Multi-point Ethernet Private Line
Ethernet Rate Shaping Services
Hitless Bandwidth Provisioning with LCAS
Link Aggregation (LNW70 LAN ports)
Ethernet/TDM Access to Frame Relay and/or ATM Service
Ethernet/TDM Access to IP Network
DMX as an Ethernet Hub using LNW70
DMX as an Ethernet Hub using LNW78
SAN Distance Extensions with DMX
Converged Service Delivery via Metropolis
TransMUX Functionality with LNW18/20
Enhanced TransMUX Functionality with LNW20
...........................................................................................................................................................................................................................................................
3 - 4
Lucent Technologies – Proprietary
See notice on first page
365-372-300
Issue 8.0 September 2006
Applications and Configurations
Established Network Evolution
............................................................................................................................................................................................................................................................
Overview
The DMX offers a capacity upgrade from an OC-3 or OC-12 network to an OC-12/48/192 network. Implementing a DMX ring at the edge of the network, in combination with pre-existing OC-3 and OC-12 rings, provides increased network capacity and flexibility with the opportunity to interwork with or replace current-generation access multiplexers.
Description
The DMX can interwork with existing Lucent and other-vendor
SONET network elements to support all of the applications and topologies described in this section. The figures below show the network evolving from an OC-3/OC-12 network to an OC-48/192
network. Figure 3-2 (3-5) shows the original network, while Figure 3-3
(3-6) shows the network evolution when once DMX is deployed.
Figure 3-2 Established Network
WBDCS/
DMX
WaveStar
®
2.5G/10G,
BWM
CO/POP
OC3/12
DDM
OC3/12
DS1,DS3, OC-3c
Customer
Location
DDM
FiberReach
Customer
Location nc-dmx-157
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
Lucent Technologies – Proprietary
See notice on first page
3 - 5
Established Network Evolution
Figure 3-3 Established Network Evolution
Applications and Configurations
WBDCS/
DMX
DS1,DS3,
OC-3/12/48
Metropolis
DMX
®
OC-12/48/192 UPSR
WaveStar
®
2.5G/10G,
BWM
DDM
OC3/12
DS1,DS3, OC-3c
CO/POP
Metropolis
®
DMX
Hub/RT
DS1,DS3
Metropolis
®
DMX
0X
1
OC-3/12
& rings
Customer
Location
Customer
Location
DDM
FiberReach nc-dmx-015
Application advantage
As greater capacity is needed, the DMX provides customers a graceful upgrade path from smaller capacity OC-3/12 networks to
OC-12/48/192 DMX networks capable of enhanced applications, topologies, and capacities. The features of the DMX enable it to cost-effectively serve your needs now while protecting your networking future.
...........................................................................................................................................................................................................................................................
3 - 6
Lucent Technologies – Proprietary
See notice on first page
365-372-300
Issue 8.0 September 2006
Applications and Configurations
Access Transport for Voice and TDM Private Line Services
............................................................................................................................................................................................................................................................
Overview
The DMX supports a full set of interfaces, topologies, and operations to provide the flexibility, upgradability, and ease of operation required to meet the dynamic requirements of the access transport environment. A
DMX OC-12/48/192 path switched ring for TDM transport of voice and private line services is a reliable infrastructure for residential or small business voice services.
Description
DMX is particularly suited to the evolving needs of voice and private line access transport applications due to its compact size, environmental hardening, and capacity growth potential. The DMX’s flexibility allows the infrastructure to be optimized for a particular fiber topology, service mix, and growth forecast. DMX can simultaneously support wideband and broadband private line services for DS1, DS3,
E1, EC-1, OC-3, OC-12, and OC-48 client interfaces.
The figure below shows a path switched ring transporting low-speed
DS1 signals that are carrying voice services from a PBX or a digital loop carrier (DLC) system over an OC-48 or OC-192 ring. In this application, DMX hands off these voice circuits to the voice switch in the central office using a very cost-effective DS1/EC-1 interface.
Figure 3-4 Voice and Private Line Access Application
CO
Customer
Location
Voice
Switch
DS1/
EC-1
Metropolis
®
DMX
DS1,DS3,
OC-3(c)/
12(c)/48(c)
OC-12/48/192
Metropolis
®
DMX
Metropolis
®
DMX
Cabinet
DS1 DLC or
PBX
DS1,DS3,
OC-3(c)/
12(c)/48(c) nc-dmx-007
Application advantage
The access transport application provides low-cost transport of revenue-generating voice and private line wideband and broadband services in a single multiplexer.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
Lucent Technologies – Proprietary
See notice on first page
3 - 7
Applications and Configurations
Interoffice Transport
............................................................................................................................................................................................................................................................
Overview
The DMX provides the features necessary for interoffice transport in a greater metropolitan area, including long-span optics, easy capacity upgrades, and add/drop interfaces to other CO equipment. A
VT1.5/STS-1 OC-48 path switched ring is a very effective self-healing network configuration for large cross-section interoffice networks.
Description
The DMX is ideal for metropolitan interoffice transport applications due to its large capacity and mixture of voice, data, and Ethernet services. An OC-12/48/192 UPSR/BLSR ring provides fast and reliable transport of DS1, E1, DS3, EC-1, OC-3(c), OC-12(c), OC-48(c), and
10/100/1000 Mbps Ethernet services.
The figure below shows a sample interoffice transport configuration.
Figure 3-5 Interoffice Transport
Central Office
DMX
OC-48/192
Central Office
DMX
OC-48/192
Central Office
DMX
DS1, DS3, E1, EC-1,
OC-3, OC-12, OC-48
10/100/1000 Mb/s
Ethernet
DS1, Ds3, E1, EC-1,
OC-3, OC-12, OC-48
10/100/1000 Mb/s
Ethernet
OC-48/192
Central Office
DMX
OC-48/192
DS1, Ds3, E1, EC-1,
OC-3, OC-12, OC-48
10/100/1000 Mb/s
Ethernet
VT1.5/STS-1 cross-connect
DS1, DS3, E1, EC-1,
OC-3, OC-12, OC-48
10/100/1000 Mb/s
Ethernet nc-dmx2-030
Application advantage
DMX’s interoffice transport applications provide low-cost, self-healing voice, Ethernet, asynchronous transfer mode (ATM), and frame relay
(FR) transport on a single multiplexer.
...........................................................................................................................................................................................................................................................
3 - 8
Lucent Technologies – Proprietary
See notice on first page
365-372-300
Issue 8.0 September 2006
Applications and Configurations
Ethernet Private Line
............................................................................................................................................................................................................................................................
Overview
Ethernet private lines provide the user the ability to transport frames completely transparently between two DMX NEs. No VLAN knowledge or packet-layer provisioning is required by the user in this application. Simple, SONET STS-1 cross-connect provisioning is all that is required. These private line capabilities allow the DMX to provide dedicated bandwidth for individual customers and fast
SONET-layer restoration in the event of a facility-based failure.
Ethernet Private Line
(point-to-point Ethernet) for
Enterprise LAN transport
DMX utilizes standard STS-1 (STS-3(c) can also be used) with virtual concatenation (ITU G.707) to transport 10/100 Mbps or 1000 Mbps
Ethernet services over a SONET OC-12/48/192 UPSR/BLSR ring. In this configuration, Ethernet traffic from an end customer may be fed to a core router in the central office (CO), while voice traffic is fed from the same ring to a voice switch in the CO. In private line LAN transport configurations, standard SONET UPSRs/BLSRs provide restoration of service within 50 milliseconds.
Figure 3-6 Ethernet Private Line Transport Application
Customer A Customer B
Server Farm
Switch/
Router
10/100Mbps
GbE
Local
Branch office
Main campus
Switch/Router
1000Mbps
GbE
Metropolis
®
DMX
Customer A
Metropolis
®
DMX
OC-192
10/100Mbps
GbE
Local
Branch office
Switch/Router
Metropolis
®
DMX
1000Mbps
GbE
OC-12/48
Metropolis
®
DMX
Regional
POP
Customer B
Main Office nc-dmx2-018
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
Lucent Technologies – Proprietary
See notice on first page
3 - 9
Ethernet Private Line
Applications and Configurations
Application advantage
Ethernet Private Lines simplify networks by eliminating intermediate
WAN protocols, such as frame relay or ATM while providing service providers an ideal migration path from traditional private line, circuit-based services.
Ethernet Private Lines also provide dedicated bandwidth and absolute
QoS for business critical data transport applications. Private lines are protected by SONET layer protection switching with a guaranteed restoration time of less than 50 milliseconds.
...........................................................................................................................................................................................................................................................
3 - 1 0
Lucent Technologies – Proprietary
See notice on first page
365-372-300
Issue 8.0 September 2006
Applications and Configurations
Multi-point Ethernet Private Line
............................................................................................................................................................................................................................................................
Overview
This section is meant to supplement the previous section (Ethernet
Private Line) and aims at better describing the Multipoint Ethernet cross connection functionality of private lines.
Multi-point Ethernet Private
Line for Enterprise LAN transport
Similar to the figure discussed in the previous section, the figure below shows a customer (Customer 1) with a private line connecting multiple sites. In such applications, multi-point connectivity enables simultaneous connectivity to all sites serviced by the private line at all times. Ethernet private line links are sized independently and are configured for 802.1q or Transparent VLAN mode, and VT Virtual
Concatenation in R5.0. Finally, in multi-point ethernet applications, the intermediate nodes (the DMX at the bottom of the ring in the figure below) provide a simple bridging function, passing-through all
Ethernet traffic on the private line. As such, the intermediate nodes do no require Ethernet functionality.
Figure 3-7 Multi-point Ethernet Private Line Application
SONET-protected
Link A
Customer 1
Metropolis
®
DMX
SONET-protected
Link B
Customer 1
Metropolis
®
DMX
OC12/48/192
UPSR
Metropolis
®
DMX
Customer 1
Metropolis
®
DMX
®
DMX = Metropolis DMX Access Multiplexer
Through Nodes do not require
Ethernet functionality nc-dmx2-034
Multicast Ethernet Packets
Multicast Ethernet packets/transmission can be used to facilitate certain private line applications. Yet, Ethernet private line can be implemented using a variety of Ethernet cross-connection types. For more information about Ethernet cross-connection types, refer to the section entitled “Cross-connections” in Chapter 5 of this document.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
Lucent Technologies – Proprietary
See notice on first page
3 - 1 1
Multi-point Ethernet Private Line
Applications and Configurations
Multicast Ethernet can also be used to facilitate video distribution, webcasting, and any other application in which multipoint Ethernet cross-connections are used. For more information on the functionality of multicast Ethernet in the DMX, refer to the section entitled
“Networking Capabilities” in Chapter 2 of this document.
Application advantage
Multi-point Ethernet Private Lines eliminate the need for an adjunct data switch and further simplify networks by eliminating intermediate
WAN protocols, such as frame relay or ATM while giving service providers an ideal migration path from traditional private line, circuit-based services.
Multi-point Ethernet Private Lines also provide absolute QoS and security for data transport applications with dedicated bandwidth and
SONET layer protection switching (less than 50 millisecond restoration time).
...........................................................................................................................................................................................................................................................
3 - 1 2
Lucent Technologies – Proprietary
See notice on first page
365-372-300
Issue 8.0 September 2006
Applications and Configurations
Ethernet Rate Shaping Services
............................................................................................................................................................................................................................................................
Overview
Rate-shaped services offer a statistical multiplexing model that makes efficient use of shared bandwidth. DMX currently supports two of the primary forms of rate shaping. The two primary forms of rate shaping are rate limiting, and guaranteed rate services (plus various combinations of both).
Rate limiting is achieved using Peak Information Rate (PIR) provisioning. Guaranteed rate service is achieved using Committed
Information Rate (CIR) provisioning. PIR institutes a limit, or
“ceiling”, of maximum bandwidth to be allocated to a particular customer at any time. CIR, on the other hand, provides a guaranteed minimum, or “floor” throughput even during periods of high congestion. DMX provides support of CIR in R5.0.
PIR
Burstable Bandwidth
CIR
Guaranteed Bandwidth nc-dmx2-032
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
Lucent Technologies – Proprietary
See notice on first page
3 - 1 3
Ethernet Rate Shaping Services
Applications and Configurations
How it Works
The figure above demonstrates the relationship between CIR and PIR services for a single customer’s bursty data stream. Again, PIR represents the maximum bandwidth a particular customer will be allocated at any time, while CIR is guaranteed minimum bandwidth that insures a constant level of service even during periods of high congestion.
As the figure above suggests, if the maximum bandwidth for a customer (PIR) is exceeded, surplus packets may be dropped. Rate guarantees can be changed in-service and are provisionable at sub-rate levels (1 Mbps).
Policing takes place first in order to ensure that a customer meets the
CIR/PIR stipulations of their contract. The priority queuing relative to other customer’s traffic then occurs providing another QoS capability.
Figure 3-8 Bandwidth Allocation within Ethernet circuit packs
Eth ports
Policing is done here, inside the Ethernet card.
PIR
Policing
Priority
Queues
(WRR)
To Ethernet switch fabric
Discarded non-
Conforming packets nc-dmx2-030
Application advantage
Rate shaping provides the capability to offer a maximum “ceiling” throughput at all times (PIR). It also supports commitments to minimum bandwidth availability (CIR). This combination of CIR and
PIR rate shaping enables DMX to both help service providers meet detailed service level agreements (SLAs) and to ensure adequate capacity for end-users at all times. SLAs also can be offered with sub-rate guarantees. Rate shaping can enable oversubscription with increased revenue potential. Finally, all private line traffic is protected by time-tested SONET layer protection (1+1, UPSR, and BLSR).
...........................................................................................................................................................................................................................................................
3 - 1 4
Lucent Technologies – Proprietary
See notice on first page
365-372-300
Issue 8.0 September 2006
Applications and Configurations
Hitless Bandwidth Provisioning with LCAS
............................................................................................................................................................................................................................................................
Overview
Link Capacity Adjustment Scheme (LCAS) enables in-service (or non-service affecting) bandwidth increases/decreases for Ethernet links.
Description
DMX supports standard LCAS per ITU G.7041. Bandwidth changes to
Ethernet links are done one span at a time. Without LCAS, provisioning a bandwidth change on the first span of a packet ring takes down Ethernet service around the rest of the ring until the entire ring is set to operate at the same capacity.
With LCAS, planned increases and/or decreases of bandwidth are hitless (that is, they do not affect service). As the figure below illustrates, when capacity changes to each span around the packet ring are provisioned, service is not interrupted. While the span between nodes A&B is set to 15 STS-1s, the remaining spans continue to function at 10 STS-1s.
Figure 3-9 Hitless Bandwidth Provisioning: 1st Span
Central Office
TDM
Capacity of span one changed to 15 STS-1s in-service. The rest of the packet ring continues to function.
Metropolis
®
DMX
15 STS-1s
OC12/48/192
Metropolis
®
DMX
Ethernet
10 STS-1s
Metropolis
®
DMX
10 STS-1s
10 STS-1s
Metropolis
®
DMX
JK-E-10.eps
Application Advantages
As the global market for communication services is in continuous flux, both advances in technology and changes in state, regional, and national economies exert various pressures on your network.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
Lucent Technologies – Proprietary
See notice on first page
3 - 1 5
Hitless Bandwidth Provisioning with LCAS
Applications and Configurations
Accordingly, capacity changes to your network are necessary on a regular basis.
LCAS enables you to meet the challenges of today’s market without affecting service. With LCAS, you are not in danger of violating stringent Enterprise customer SLAs. You can also deploy you SONET network according to long-term growth forecasts, and get the most out of the ability to adjust private line and packet ring capacity within your
SONET lines.
...........................................................................................................................................................................................................................................................
3 - 1 6
Lucent Technologies – Proprietary
See notice on first page
365-372-300
Issue 8.0 September 2006
Applications and Configurations
Link Aggregation (LNW70 LAN ports)
............................................................................................................................................................................................................................................................
Overview
DMX supports link aggregation on any two LNW70 LAN ports of the same rate (i.e. 100 or 1000 Mbps), operating in switched mode. In
R7.0, the two ports comprising a LAG must be located on the same pack.
Link aggregation can also provide facility protection on LNW70 LAN ports.
Description
Ordinarily, multiple Ethernet links between two bridges form loops
(unless a spanning tree blocks all but one) so they can’t be used to increase bandwidth. Link Aggregation causes defined groups of links to be treated as a single logical link, making multiple LAN ports appear as one. In this way, Bandwidth may be increased without requiring an upgrade to a higher rate link.
Link aggregation can also remove failed links automatically, thereby providing a means of facility protection. When a link fails, traffic is shifted to the remaining links in that Link Aggregation Group (LAG).
More links than are needed can be added to the group and each is active until it fails (similar to utilizing LCAS protection for SONET tributaries).
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
Lucent Technologies – Proprietary
See notice on first page
3 - 1 7
Link Aggregation (LNW70 LAN ports)
Applications and Configurations
Link Aggregation Example
The figure below depicts link aggregation on two LNW70 LAN ports functioning at 100Mbps. The top portion of the figure shows two ports receiving separate 100 Mbps inbound flows. The bottom portion depicts the same two flows being equally split across the two outbound ports in the LAG. In this example, no failure has occurred and both ports comprising the LAG are in-service.
Traffic entering incoming ports is aggregated into a LAG. While both ports are in-service, outgoing traffic is split between working ports.
Figure 3-10 Link aggregation at 100 Mbps
(all ports in-service)
Link Aggregation Group (LAG)
100 Mb
100 Mb
Up to
200 Mbps
LNW70
Link Aggregation Group (LAG)
LNW70
100 Mb
100 Mb
200 Mbps per conversation
MA-DMXAPG-044
The instance pictured above represents the ideal case, in which there are at least 2 flows, each a maximum of 100Mbps. In this case they can be equally split over the two ports comprising the LAG. The ability to split the two flows across multiple ports also depends on the distribution of MAC/IP addresses.
Link aggregation employs an algorithm that assigns traffic to member ports to prevent misreading. A given flow can be assigned to only one port and cannot be split across multiple ports in the same LAG. To increase flexibility, DMX allows a flow to be defined by either a MAC source and destination address pair or an IP source and address pair.
The algorithm uses the XOR of the least significant bits of the address pairs to assign a port/link. Therefore, the actual load balancing achieved depends on the distribution of MAC/IP addresses.
...........................................................................................................................................................................................................................................................
3 - 1 8
Lucent Technologies – Proprietary
See notice on first page
365-372-300
Issue 8.0 September 2006
Link Aggregation (LNW70 LAN ports)
Applications and Configurations
Application advantage
Link Aggregation provides a means of supporting facility protection and bandwidth increases/decreases on LNW70 LAN ports. Link
Aggregation causes defined groups of links to be treated as a single logical link and removes failed links automatically, thereby enabling bandwidth changes and facility protection on 2 paired links comprising a LAG.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
Lucent Technologies – Proprietary
See notice on first page
3 - 1 9
Applications and Configurations
Virtual LAN Services
............................................................................................................................................................................................................................................................
Overview
The Virtual LAN (VLAN) Service application provides a packet-based
Ethernet connection via a shared packet over SONET connection.
Description
VLAN Service applications can be utilized by multiple customers over a shared ring for improved bandwidth efficiency. DMX uses VLANs and allows bandwidth to be shared among customers. Up to 4093
VLANs can be assigned to guarantee privacy among various customers.
Multiple customers can use the VLAN interconnect (multipoint LAN) capability of DMX at multiple sites.
The figure below shows DMX’s varied VLAN capabilities.
Figure 3-11 VLAN Service Application
DMX 100/1000M
Ethernet
Switch/
Router
Switch/
Router
100/1000M
Ethernet
DMX
DMX
OC-48/192
DMX
DMX
OC-48
CO/Regional
Hub
DMX
ISP
Router
Ethernet
OC-48
DMX
10/100/1000M bps Ethernet
Application
Server
Switch/
Router nc-dmx2-014
Application advantage
DMX Ethernet services extend packet switching from the LAN to the
WAN. In doing so, enterprise interconnect locations in metropolitan areas can transport traffic much more efficiently over shared and/or provisionable access bandwidth. ISP carrier access applications can use spanning tree protection and flexible bandwidth allocation (using
STS-1 virtual concatenation) in the WAN.
...........................................................................................................................................................................................................................................................
3 - 2 0
Lucent Technologies – Proprietary
See notice on first page
365-372-300
Issue 8.0 September 2006
Applications and Configurations
Transparent LAN Services
............................................................................................................................................................................................................................................................
Overview
The enterprise LAN (local area network) interconnect and transport applications provide business-to-business networking of routers and data switches. Transparent LAN service is similar to VLAN service, except that Transparent LANs can be deployed using rate shaping OR on a best effort basis.
Enterprise LAN interconnect (multipoint
Ethernet) description
The multipoint LAN interconnect capability of DMX allows data to be transported across a DMX network from any point to any other point.
Protection is provided via the standard spanning tree algorithm. The
DMX software determines which DMX NE is the “root” of the data network. The data spans out from that DMX NE, enabling the customer to extend its enterprise network into the WAN as a virtual private LAN.
The figure below depicts two high-speed DMX path switched rings transporting data in either a point-to-point or multipoint configuration between DMX clients through multiple nodes and switching points.
Figure 3-12 Transparent LAN Services
Customer 2
FE
Customer 3
FE
Metropolis
®
DMX
Services:
Point-to-Point
Multi-Point Broadcast
Aggregation
Customer 2
FE
Metropolis
®
DMX
Customer 1
FE
OC-12/48/192
UPSR or
BLSR
Metropolis
®
DMX
Customer 3
FE
Customer 1
FE
1GbE
Customer 2
FE = Fast Ethernet (10/100 Mbps)
GbE = Gigabit Ethernet (1000 Mbps)
Metropolis
®
DMX
1GbE
Customer 1 nc-dmx2-012
Multicast Ethernet Packets
Multicast Ethernet packets/transmission can be used to facilitate certain
Transparent LAN applications. Yet, Transparent LANs can be implemented using a variety of Ethernet cross-connection types. For more information about Ethernet cross-connection types, refer to the
section entitled Cross-connections (5-26).
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
Lucent Technologies – Proprietary
See notice on first page
3 - 2 1
Transparent LAN Services
Applications and Configurations
Multicast Ethernet can also be used to facilitate video distribution, webcasting, and any other application in which multipoint Ethernet cross-connections are used. For more information on the functionality of multicast Ethernet in the DMX, refer to the section entitled
“Networking Capabilities” in Chapter 2 of this document.
Application advantage
The Transparent LAN application supports fast, packet-layer protection throughout the WAN, as well as the ability to offer both dedicated and shared bandwidth transport services with improved efficiency and flexible quality of service (QoS).
...........................................................................................................................................................................................................................................................
3 - 2 2
Lucent Technologies – Proprietary
See notice on first page
365-372-300
Issue 8.0 September 2006
Applications and Configurations
Best Effort Ethernet Service
............................................................................................................................................................................................................................................................
Overview
Best effort Ethernet Services is an over-subscription service model that functions without Rate Shaping. Ideal for broadband Internet access within a metro area, Best Effort Ethernet Service enables service providers/carriers to offer an economy-class of service that maximizes revenue potential of a fixed amount of bandwidth.
Description
In the Best Effort service model customers share common bandwidth and are given no quality of service (QoS) or throughput rate guarantees.
Thus best effort applications function without rate shaping services and provide customers with throughput relative to available bandwidth only.
If customers require that their traffic be separated from common network traffic (for security purposes), this can be achieved by VLAN tagging (IEEE 802.1q) or Transparent VLANs (see the sections above).
Traffic in best effort applications may also be prioritized via IEEE
802.1p tags.
Protection in this application is provided by both standard SONET layer switching within the WAN and Rapid Spanning Tree protocol
(IEEE 802.1w) in the Ethernet environment.
Application Advantages
Best effort services are ideal for providing Internet access. This application enables service providers to offer economy-class service facilitated by over-subscribing bandwidth shared by numerous customers. Thus best effort services enable service providers/carriers to maximize the revenue potential of a fixed amount of bandwidth.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
Lucent Technologies – Proprietary
See notice on first page
3 - 2 3
Applications and Configurations
Ethernet/TDM Access to Frame Relay and/or ATM Service
............................................................................................................................................................................................................................................................
Overview
The DMX supports business data access applications for a variety of broadband service interfaces. These services can cost-effectively reach remote data aggregation switches at collocated sites and business premises.
Description
In this application, DMX transports DS1, DS3, OC-3, OC-12, and
OC-48 (c) signals from an edge aggregator (Figure 3-13 (3-24)) to the
core switch. It also provides DS1 and DS3 (TDM) low-cost backhaul of frame relay and ATM to the hub multiservice switch. This application also provides 10/100/1000 Mbps Ethernet transport and switching.
Figure 3-13 DMX Providing Access to Frame Relay and/or ATM
Network
METRO
POP
ISP Edge
Switch/Router
FR/ATM
TDM access
LAN
10/100/1000
Mbps and or
TDM
FR/ATM
UNIT
FR/ATM
UNIT
LAN
Ethernet access
Metropolis
®
DMX
DS1/DS3
GbE Packet Ring
(Flexible nx STS1 statistical pipes) Metropolis
®
DMX
Application advantage
PVC
FR/ATM
Network
FR/ATM
UNIT nc-dmx2-017
DMX satisfies evolving data service delivery requirements for business customers through its flexible, scalable access network infrastructure, offering a next-generation infrastructure that is stable against the churn of data technology.
DMX simplifies data service delivery by enabling access to existing
ATM and Frame Relay networks through Ethernet and/or TDM interfaces. Thus, traffic originating at Frame Relay or ATM equipment can enter the DMX through a 10/100/1000 Mbps Ethernet or DS1/DS3
TDM interface to be transmitted across SONET networks to its final destination (be it a Frame Relay/ATM based network or an Ethernet
LAN).
...........................................................................................................................................................................................................................................................
3 - 2 4
Lucent Technologies – Proprietary
See notice on first page
365-372-300
Issue 8.0 September 2006
Applications and Configurations
Ethernet/TDM Access to IP Network
............................................................................................................................................................................................................................................................
Overview
DMX provides access to the IP service delivering platforms, which enable such capabilities as virtual routing services, Layer 3 VPNs, firewalling, and IPsec Tunnels. These enhanced IP services allow service providers to offer customers state-of-the-art networking capabilities such as network based VPNs, built-in QoS, bullet-proof security, multi-tenant Internet access, voice/data convergence, and other next generation applications.
Description
While DMX single-handedly enables such things as voice/data convergence, it is important to state that the majority of the services listed above are supported by various IP Services platforms (Lucent’s
Access Point
®
Routers, and Brick Firewall Family for example). The
DMX, however provides an efficient and crucial link between metro area networks and these IP Services platforms located in the network core.
In the figure below the DMX is hosting an OC-48/192 metro ring connected to an OC-12/48 access ring on one end, and the metro core on the other. On the access ring side, DMX provides a link to CPE sized multiplexers (which are in turn connected to routers or firewalling platforms) or directly to IP routers (over 10/100/1000 Mbps
Ethernet interfaces).
On the other side of the metro ring, the DMX is connected to an IP
Services switch (both TDM and Ethernet interfaces supported by some
IP switches). IP services switches can then provide a range of enhanced
IP services.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
Lucent Technologies – Proprietary
See notice on first page
3 - 2 5
Ethernet/TDM Access to IP Network
Applications and Configurations
Figure 3-14 DMX providing Ethernet/TDM access to the Internet
IP
802.1q VLAN or Transparent VLAN IP/IP-Sec
MPLS VPN
Main Service Node
Gx550
Class 5
Switch
10/100 Mbps
No Firewall
VLAN
Metropolis
®
DMX press
LAN traffic over right sized
STS1-xv
Hub
Node
OC-12/48
Access Ring
Metropolis
®
DMX
Metropolis
®
DMX press
GbE
VPN Bricks
(Firewall),
SuperPipe
(VPN router)
OC-48/92
Access Ring
Metropolis
®
DMX
10/100 Mbps and or GbE
IP VPN to the
Internet
FR/ATM
UNIT nc-dmx2-016
Application Advantages
DMX allows service provider’s access networks to support today’s enterprise customer needs with TDM to IP services migration, access to high-security multiservice platforms (i.e. SpringTide
®
), and efficient aggregation of last-mile voice and data services.
...........................................................................................................................................................................................................................................................
3 - 2 6
Lucent Technologies – Proprietary
See notice on first page
365-372-300
Issue 8.0 September 2006
Applications and Configurations
DMX as an Ethernet Hub using LNW70
............................................................................................................................................................................................................................................................
Metropolis
®
DMX
Overview
Description
When DMX is equipped with the LNW70 and used as a metro Ethernet hub, it presents many advantages over other next-generation and non next-generation metro ADMs.
At the metro edge, the Metropolis
®
Portfolio provides integrated
CPE/MSPP functionality. With Ethernet over SONET (EoS), the
Metropolis
®
Portfolio supports full- or sub-rate GbE packet rings. It supports Transparent (802.1q) or Stacked VLANs and can provide
802.1w rapid spanning tree restoration (802.1d also supported) whether functioning in Private Line or Packet Ring mode.
Figure 3-15 DMX as an Ethernet Hub
Single DMX for Metro Hub
OC-12/48/192
Metropolis
®
DMX
Metropolis
®
DMX
tend
10/100/1000 Mbps
Ethernet, plus TDM
Metropolis
®
DMX
plore
OC-3/12/48
OC-3/12/48
OC-3/12/48
OC-12/48/192
OC-12/48/192
OC-3/12/48
OC-3/12/48
OC-3/12/48
OC-3/12/48
OC-3/12/48
OC-3/12/48
LNW70
GE
®
DMX = Metropolis DMX Access Multiplexer
DMX
plore
®
= Metropolis DMX
plore
Access Multiplexer
DMX
press
= Metropolis
®
DMX
press
Access Multiplexer
DMX
tend
= Metropolis
®
DMX
tend
Access Multiplexer
MA-DMX-409
As shown in the figure above, the LNW70 contains enough capacity and external ports to aggregate and transmit 2.5 Gigabits per second of
Ethernet traffic. The integrated packet switch can connect multiple packet rings and/or point-to-point “spokes”. DMX also supports optical/Ethernet hairpinning at full-rate GbE line speed. Finally, with the LNW70, DMX provides optical 100BASE-X and 1000BASE-X, along with electrical 10/100BASE-T and 1000BASE-T ports on one
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
Lucent Technologies – Proprietary
See notice on first page
3 - 2 7
DMX as an Ethernet Hub using LNW70
Applications and Configurations
card for data traffic aggregation at the metro edge or data traffic hand-off at the metro core.
Application Advantages
DMX provides superior Ethernet aggregation and switch capacity with the LNW70. Each LNW70 supports an industry leading, single circuit pack capacity of 2.5Gbps. It supports both optical 100BASE-X and
1000BASE-X, along with electrical 10/100BASE-T and 1000BASE-T optical ports on the same pack, allowing you to provision the most appropriate and rate-specific data cross-connections for your network.
This helps you to get the most out of your investment in both metro edge and data core NEs.
With an array of Ethernet topologies to choose from, DMX allows you to deploy the most appropriate network for your customers’ needs.
Support of industry standard Private Lines and Packet rings, with both
SONET and spanning tree protection schemes, ensures your ability to interwork with CPE networks and provide your customers with the highest level of reliability possible. R5.1 also makes such billable services as CIR and PIR available in structuring Enterprise SLAs.
Meeting the reliability requirements of stringent SLAs is easier given
R5.1’s support of LCAS, which enables hitless bandwidth provisioning.
DMX provides all of these capabilities within an industry leading TDM
NE that scales from DS1/E1 to OC-192 in the same, compact unit. This makes DMX capable of aggregating both Ethernet and SONET traffic with the highest levels of speed, security, and sophistication possible.
...........................................................................................................................................................................................................................................................
3 - 2 8
Lucent Technologies – Proprietary
See notice on first page
365-372-300
Issue 8.0 September 2006
Applications and Configurations
DMX as an Ethernet Hub using LNW78
............................................................................................................................................................................................................................................................
Overview
The LNW78 support both RPR and EoS services on a single card. The
LNW78 also supports CoS features on EoS VCGs, including the same classification options for incoming packets, queuing/scheduling capabilities for outgoing packets, and CIR/PIR rate shaping functionality as were previously supported only on 802.3 LAN ports.
This increased functionality allows DMX to offer hybrid
RPR/hub-and-spoke functionality where the LNW78 acts as a point of both aggregation for remote LAN ports (or customer ports) and interconnection, linking remote LAN ports to an RPR ring.
Hybrid hub-and-spoke/RPR interconnect
As the figure below demonstrates, employing the LNW78 at a hub node enables DMX to support hub-and-spoke configurations similar to the hubbing application using the LNW70 described in the previous section. As the LNW78 also supports RPR, it can aggregate remote
LAN ports and connect their traffic to an RPR ring.
Figure 3-16 Hybrid hub-and-spoke/RPR interconnect with LNW78
SONET
6 Eos VCG
With Rate Controls
Metropolis
®
DMX
plore
VLNC15
Metropolis
®
DMX
plore
VLNC15
LNW78
RPR Port Unit
RPR Ring
RPR VCG
LNW78
RPR Port Unit
RPR VCG
LNW78
RPR Port Unit
Metropolis
®
DMX
LNW70
LNW78
RPR Port Unit
Metropolis
®
DMX
tend
LNW74
Metropolis
®
DMX
tend
LNW74
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
Lucent Technologies – Proprietary
See notice on first page
3 - 2 9
DMX as an Ethernet Hub using LNW78
Ne-local LAN port aggregation/interconnect
Applications and Configurations
The NE-local LAN ports aggregation/interconnect configuration below functions similar to the application described above except that the connections to Ethernet pack(s) providing LAN ports is via backplane hairpin(s).
The figure below shows more benefits enabled by EoS functionality on the LNW78. Both private lines dropped from an optical ring and local
Ethernet LAN ports (LNW70 and LNW74 in the figure below) can be hairpinned through the shelf backplane and added to the RPR ring. If a shelf is equipped with both LNW70 and LNW78 packs, the Ethernet switch on the LNW70 can be used to aggregate traffic from multiple ports into a single point-to-point connection to an LNW78 EoS VCG.
Figure 3-17 DMX as an Ethernet Hub
MAIN MAIN
Aggregated Traffic
From a SW Port Card
RPR VCG
EoS VCG
OC-3/12/48
LNW78 LNW74 LNW70
Local LNW78 Ports
Remote Private Line via
Optical Ring
OC-n
Local 10/100
Ports
Local 100/1000
Mbps Ports
Additional Local LAN
Ports to RPR
MA-DMXAPG-050
Application Advantages
This application allows lower cost edge ports that may not have the sophistication of DMX’s Ethernet capabilities to be rate controlled with
CIR/PIR rate shaping. It also provides that added benefit of RPR/LAN port interconnect without requiring the use of physical LAN ports, additional Ethernet circuit packs, PTMs (SFPs), and associated cabling and craft personnel time needed to establish the interconnect.
...........................................................................................................................................................................................................................................................
3 - 3 0
Lucent Technologies – Proprietary
See notice on first page
365-372-300
Issue 8.0 September 2006
Applications and Configurations
Ethernet Transport via RPR
............................................................................................................................................................................................................................................................
Overview
DMX supports Resilient Packet Ring (RPR) Ethernet transport compliant with IEEE 802.17. RPR is intended to optimize
Ethernet-based metro ring networks for packet transport with resiliency equivalent to that of SONET rings. It could be used to carry voice and
TDM traffic with the QoS of SONET and ATM combined, while supporting LAN traffic with the efficiency of Ethernet. It also employs a fairness algorithm to allow equal access to opportunistic bandwidth regardless of a node’s position around the ring. RPR is a useful alternative to Ethernet over Fiber for carriers, cable operators, large enterprise networks, and municipal utilities-owned networks.
Bridging in RPR
DMX’s RPR implementation uses enhanced Ethernet bridging as well as basic Ethernet bridging. As shown in the figure below, basic bridging is much different than enhanced bridging. Chief among their differences is that enhanced bridging allows for spatial reuse, meaning that other nodes around the ring can reuse opportunistic bandwidth.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
Lucent Technologies – Proprietary
See notice on first page
3 - 3 1
Ethernet Transport via RPR
Applications and Configurations
Basic Bridging
With basic bridging (side “a” of the figure below), packets that originate at any node on the ring are flooded. Flooding means they are sent to every node around the ring, regardless of their destination. With basic bridging, all nodes see all packets, making it a simple form of reliable transport. The downside of flooding packets with basic bridging is that it negates the possibility of spatial reuse, one of the great benefits of RPR.
Figure 3-18 Basic vs. Enhanced Bridging
1 1
Y Y
8 2 8 2
7
B
3 7
A
6 4
5
X
Basic with Unidirectional Flooding
3
6 4
5
X
Enhanced with Spatial Reuse
MA-DMXplore-061
Enhanced Bridging
Enhanced bridging is a more efficient form of RPR transport that allows for the possibility of spatial reuse. As shown in side “b” of the figure above, enhanced bridging allows the nodes to learn the location of the node to which the destination address belongs. All subsequent transmissions for that data stream are unicast by the shortest path. This means that packets are not flooded around the ring, but are sent directly to the destination node. This leaves the unused bandwidth around the rest of the ring open for additional traffic.
...........................................................................................................................................................................................................................................................
3 - 3 2
Lucent Technologies – Proprietary
See notice on first page
365-372-300
Issue 8.0 September 2006
Ethernet Transport via RPR
Applications and Configurations
Steering Protection
DMX uses steering protection to recover from failures in RPR. As shown in the figure below, all the nodes around the RPR ring learn of a failure through topology messaging. The nodes then redirect transmission to reach destination addresses. RPR steering provides <50 msec recovery time (similar to SONET) and is revertive.
Steering with Enhanced Bridging
The figure below depicts steering protection as it would function with
Enhanced RPR bridging. Again, with enhanced bridging all nodes learn the location to which the destination address belongs and transmit packets one-way (unicast), directly toward the destination node. If packets are originating at node “x” and their destination is node “y”, and a failure occurs in the shortest path, the “x” node will perform the steering function to send packets back around the ring in the other direction. With enhanced bridging, the post-failure transmissions will also be unicast.
Figure 3-19 Steering Protection with Enhanced Bridging
Enhanced Bridging
1 1
Y Y
8 2 8 2
7
X
6
5
X
Before Steering
4
3 7
X
6
5
X
After Steering
4
3
MA-DMXplore-063
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
Lucent Technologies – Proprietary
See notice on first page
3 - 3 3
Ethernet Transport via RPR
Applications and Configurations
Steering with Basic Bridging
The figure below depicts steering protection with basic bridging. Basic bridging functions using unidirectional flooding (see the graphic on the left of the figure below). If the RPR ring is set to use basic bridging with unidirectional flooding, steering will force it into bidirectional flooding as pictured on the right side of the figure below.
Figure 3-20 Steering Protection with Basic Bridging
Basic Bridging
1 1
Y Y
8 2 8 2
3 7
X
6 4
5
X
Before Steering
(Unidirectional Flooding)
Cleave point - Based on
Failed Span
7
X
6
5
X
After Steering
(Bidirectional Flooding)
4
3
MA-DMXplore-064
As is the case with enhanced bridging, steering directs traffic away from the failure point. With basic bridging, the steering function will change the cleave point in the RPR ring to the point of failure. All traffic will still be broadcast in both directions, around the entire ring.
...........................................................................................................................................................................................................................................................
3 - 3 4
Lucent Technologies – Proprietary
See notice on first page
365-372-300
Issue 8.0 September 2006
Ethernet Transport via RPR
Applications and Configurations
Fairness and Spatial reuse Spatial Reuse
RPR provides support for spatial reuse, whereby unused bandwidth around the ring can be used to facilitate transport of additional traffic.
Spatial reuse is supported only in enhanced bridging scenarios where the unused portion of the ring is left open to additional traffic (See
).
With enhanced bridging (as in Figure 3-18), Node 1 can transmit traffic
to Node 2 at the full ring rate, while Node 2 can transmit traffic to Node
3 at the full ring rate. The same capability is enabled at the other nodes around the ring because the traffic originating at each node stops at its destination node.
Fairness
Fairness is accomplished by way of an algorithm that functionally throttles the access to this unused bandwidth at each node around the ring in an effort to provide equal access for all best-effort traffic.
Fairness allows best-effort users (Class C users, or Class B users that are transmitting traffic at a rate higher than their specified CIR) equal access to any available, unreserved bandwidth. Bandwidth reserved for
Class A users can’t be used by any other class. The unreserved bandwidth is the difference between the maximum ring rate and the reserved bandwidth (what is left over). The fairness algorithm then prevents any one node from having greater access to unreserved bandwidth than the other nodes around the ring.
Figure 3-21 Fairness in RPR
250 Mb
250 Mb
200 Mb
1
8
2
200 Mb
7
700 Mb available
3
6 4
5
300 Mb
(offered)
Initial Condition
300 Mb
(offered)
Steady State
MA-DMXplore-066
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
Lucent Technologies – Proprietary
See notice on first page
3 - 3 5
Ethernet Transport via RPR
Applications and Configurations
The figure above depicts a typical RPR ring where a total of 700 Mbps is unreserved. If there is only one best-effort user on the ring, that user can send a maximum of 700 Mbps. If there is another best-effort user at another node transmitting traffic, the first node is throttled back to allow the second equal access to bandwidth.
On the left side of the figure above, both Node 5 and 6 have 300 Mb to transmit to Node 8. If they were the only best-effort users on the ring transmitting traffic at this time, there would be no problem. Yet, Node 7 is also trying to transmit 200 Mb of traffic to Node 1. Initially, because there is already 600 Mb of traffic (from Nodes 5 and 6) in route, Node 7 can only get 100 Mb of traffic through to Node 1.
As a result, it sends a message to Node 6 (shown as the black arrows inside the ring), informing it that it can only send 100 Mb of its total payload. Node 6 immediately reduces its transmit rate to 100 Mbps and sends a similar fairness message to Node 5. Node 5 then responds in a similar fashion to Node 6.
With this feedback control system, the transmit rates and fairness messages adjust to converge on a steady state average of 250 Mb for
Nodes 5 and 6, and 200 Mb for Node 7. The reason that the rates aren’t all equal is because Node 7 only needs to send 200 Mb to start with.
In this example fairness ensures that all nodes with best-effort users share unreserved bandwidth equally. Node 7 is allowed to transmit its entire payload only because the capacity is less than the capacity that can be allocated to each of the other two nodes hosting best-effort users.
...........................................................................................................................................................................................................................................................
3 - 3 6
Lucent Technologies – Proprietary
See notice on first page
365-372-300
Issue 8.0 September 2006
Ethernet Transport via RPR
Applications and Configurations
RPR interconnect with
LNW78 EoS functionality
The figure below shows two RPR rings connected via an EoS link. The rings are linked together through EoS VCGs LNW78 located on different shelves. The Eos ports on the LNW78(s) connect the Ethernet switches located on the packs, thereby providing a bridge between the two RPR rings. This eliminates the need to use physical LAN ports, additional Ethernet circuit packs, PTMs (SFPs), and associated cabling to establish the interconnect. On each shelf shown below traffic is mapped to EoS ports. The EoS ports are then connected to an optical interface, in this case, via a hairpin connection. The two shelves are connected by an optical ring (or 1+1). Ethernet traffic can now flow between RPR rings.
Figure 3-22 RPR Packet Ring interconnect via EOS VCG with
LNW78 (multi-node interconnect)
RPR Ring 1
Metropolis
®
DMX
LNW78
Metropolis
®
DMX
LNW78
OC-n
LNW78
Metropolis
®
DMX
LNW78
Local Hairpin – LNW78 to
Optical Port Unit
OC-n
Optical Shelf
Interconnect
Local Hairpin – LNW78 to
Optical Port Unit
LNW78
Metropolis
®
DMX
LNW78
OC-n
Metropolis
®
DMX
LNW78
Metropolis
®
DMX
LNW78
RPR Ring 2
MA-DMXAPG-051
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
Lucent Technologies – Proprietary
See notice on first page
3 - 3 7
Ethernet Transport via RPR
Applications and Configurations
Metropolis
®
DMX
LNW78
As the figure below shows, the link between the two rings can be established using LNW78s located on the same shelf. In this example, the two RPR rings reside on a single shelf. As in the multi-NE shelf example, Ethernet traffic is mapped to EoS ports. The difference in this figure is that the EoS ports on each card are connected to each other via an internal hairpin.
Figure 3-23 RPR Packet Ring interconnect via EOS VCG with
LNW78 (single-node interconnect)
RPR Ring 1
Metropolis
®
DMX
LNW78
OC-n
LNW78
LNW78
Local Hairpin –
LNW78 to LNW78
Metropolis
®
DMX
LNW78
Metropolis
®
DMX
LNW78
OC-n
Metropolis
®
DMX
LNW78
LNW78
RPR Ring 2
®
DMX = Metropolis DMX Access Multiplexer
MA-DMXAPG-052
RPR ring interconnect via EoS connects multiple rings without making them the same ring. This is advantageous because all functions of the rings remain separate, including node-based bandwidth allocation around the RPR as governed by the fairness algorithm.
...........................................................................................................................................................................................................................................................
3 - 3 8
Lucent Technologies – Proprietary
See notice on first page
365-372-300
Issue 8.0 September 2006
Ethernet Transport via RPR
Applications and Configurations
Application Advantages
RPR can offer the following advantages over Ethernet over Fiber and
SONET transport for data traffic.
• Optimizes SONET rings for Ethernet transport with <50 msec restoration.
• Could be used to transport voice, TDM, and data traffic with the efficiency of Ethernet
• RPR offers efficient allocation of SONET timeslots for leased line data services.
• RPR can be oversubscribed, with equal access to opportunistic bandwidth.
• Best-effort classes of service use opportunistic, unreserved bandwidth. RPR does not reserve protection bandwidth. It doesn’t have unused links as with the Spanning Tree protocol.
• Enhanced bridging only uses the direct path between source and destination, allowing for spatial reuse.
• RPR supports a fairness algorithm used to distribute access to opportunistic bandwidth around the ring. Even when two RPR rings are connected via EoS VCGs on the LNW78, all ring functionality remains separate. This allows fairness to function independently relative to each ring.
• RPR supports 3 classes of service:
– Class A: CIR= PIR (used for voice, video, and circuit emulation)
– Class B: CIR and PIR (guaranteed bandwidth, everything above the CIR and below the PIR has best-effort, fairness controlled access to opportunistic bandwidth)
– Class C: CIR=0 (all traffic is best-effort, fairness controlled)
• CoS functionality on EoS VCGs extends the same classification options for incoming packets, queuing/scheduling capabilities for outgoing packets, and CIR/PIR rate shaping functionality as were previously supported only on 802.3 LAN ports. Therefore traffic originating on low-cost remote LAN/customer ports that may not have the advanced Ethernet capabilities of DMX can be managed with QoS support available on EoS VCGs.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
Lucent Technologies – Proprietary
See notice on first page
3 - 3 9
Applications and Configurations
SAN Distance Extensions with DMX
............................................................................................................................................................................................................................................................
Overview
Description
With today’s increasing regulations and heightened concern with
Business Continuity and Disaster Recovery, both large and small businesses must consider alternate storage architectures for distance extensions. DMX can provide a ubiquitous, flexible, highly reliable platform for both TDM and data-based transport, including voice, DSn private line, Ethernet, and storage (SAN) traffic.
When SAN deployments began in corporations and colleges, it was to serve the needs of various, unique departments within a larger organization. The resulting situation, depicted in the figure below, is one of multiple SAN Islands made up of disparate technology with various management and transport requirements.
Figure 3-24 SAN Islands Today
There are three options available to connect SAN islands: IP, WDM, and SONET. IP is attractive due to its high availability, but it is non-deterministic and prone to packet loss. This makes IP incapable of providing both the capacity and reliability necessitated by enterprise requirements. WDM is not widely available for enterprises today, but is a good choice for large data center connectivity and those enterprises that require many storage ports.
SONET, on the other hand, is ubiquitously available and accepted as a data transport platform by business customers. It provides the most attractive balance of QoS and capacity for small to large-sized
Enterprises running both synchronous (disk mirroring) and asynchronous (data replication/backup) applications. With new technology such as GFP, VCAT, and LCAS, SAN over SONET enables simple deployment and traffic engineering for carriers, while ensuring efficient transport by way of low overhead byte count and flexible framing. Due to SONET’s advanced protection capabilities it can guarantee little or no packet loss for SAN transport. Plus, given
...........................................................................................................................................................................................................................................................
3 - 4 0
Lucent Technologies – Proprietary
See notice on first page
365-372-300
Issue 8.0 September 2006
SAN Distance Extensions with DMX
Applications and Configurations
Ethernet’s incorporation into SONET platforms, SAN management can be easily centralized and performed over IP. For reliability, capacity, and ease of deployment/management SONET is the clear choice when considering the creation of corporate and campus SAN extensions.
Application Advantages
In addition to GFP, VCAT, and LCAS, Metropolis DMX products incorporate a full array of SAN interfaces on a single card to enable efficient SAN transport over SONET. The DMX SAN card uses PTM
(Pluggable Transmission Module) optics, also known as SFP optics, to provide FICON, ESCON, and Fibre-channel interfaces. The same card can be used on both the Metropolis DMX and DMXtend, enabling rollout of new services from the metro core to edge, where and when they are requested. It can be equipped with four 200Mbps ESCON ports or four 1Gbs, two 2Gbs, or a mix of one 2Gbs and two 1Gbs
FICON/FC ports. The Metropolis SAN implementation offers standards-based buffer-to-buffer credit management for long distance operations, sub-rate allocation of asynchronous FC traffic, and provisionable bandwidth levels.
The Metropolis DMX and DMXtend are the ideal platforms for
SAN/SONET connectivity. They can easily connect various enterprise
SAN islands no matter what protocol is used. The figure below is a network view of multiple SANs connected within the same building or business park, across a region and nation-wide.
Figure 3-25 Metropolis
®
DMX Product Family SAN Transport
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
Lucent Technologies – Proprietary
See notice on first page
3 - 4 1
Applications and Configurations
Converged Service Delivery via Metropolis
®
DMX Product Family
............................................................................................................................................................................................................................................................
Overview
Description
Modern Ethernet/SONET MSPPs like DMX have made it simple for a single provider to offer voice, data, and video on a common, easy-to-manage platform. The hybrid Ethernet/SONET nature of DMX has made it an integral part of the top Service Provider (SP) networks moving toward converged offerings. In addition to convergence, there are a host of new service opportunities that demand intelligent access solutions. These include services like Storage Area Network (SAN) distance extensions, secure VPNs, and VoIP; all of which are receiving great attention from industry media and promise high market demand in the future.
The Metropolis
®
DMX, DMXplore and DMXtend offer high bandwidth optical access at the OC-3/12/48 level in conjunction with
DS1/3 interfaces for voice traffic, Fast Ethernet (10/100 Mbps) and
Gigabit Ethernet (1000Mbps) for integrated data transport, and on
DMX and DMXtend, native SAN interfaces
(FICON/ESCON/Fibre-Channel) all in one compact, low-cost unit.
These characteristics make the DMX family ideal next-generation converged platforms for their ability to address the concerns of both
SPs and end-users alike.
Figure 3-26 Metropolis
®
DMX Family Providing Converged
Service
Metropolis DMX/ DMX
tend/
DMX
plore
DS1/DS3
Voice
10/100/
1000 Mbps
Ethernet
SAN
FICON/
ESCON/FC
SONET
OC-3/12/48
Voice
DATA/
Ethernet
SAN
OC-3/12/48/192 high-speed lines provide connections with enough bandwidth to service even very high-bandwidth FTTB and FTTH applications. The rich feature set of the Metropolis
®
DMX family includes support of Ethernet QoS protocols that rival offerings from other industry vendors and, combined with the legendary reliability of
...........................................................................................................................................................................................................................................................
3 - 4 2
Lucent Technologies – Proprietary
See notice on first page
365-372-300
Issue 8.0 September 2006
Converged Service Delivery via Metropolis® DMX Product Family
Applications and Configurations
SONET, provides an extremely resilient platform ensuring low-latency and fast restoration in the event of failures. Finally, because the
Metropolis
®
DMX Family is SONET-based and provides fully integrated interfaces for data transport, they can enable SPs and
Enterprises alike to preserve their investment in existing network assets.
Application Advantages
With a metro platform that provides integrated multi-service access,
Enterprises can continue to employ their entire data infrastructure, simply connecting to the DMX/DMXplore/DMXtend at the point of transport. In addition to protecting their existing investments in hardware, this approach also enables the continued use of platforms and procedures used to manage their internal LAN. On the SP side, integrated access amounts to enabling converged service offerings with similar advantages. SPs can deliver more revenue generating services without the use of multiple CPEs/CO access devices. This is both an attractive prospect for enterprises, and allows SPs to keep OPEX under control. As SONET-based platforms, the Metropolis
®
DMX Family can interoperate with SP management systems and be easily integrated into their network.
Across the board, industry analysts agree that OPEX and CAPEX reductions are the compelling force for upgrading to next-generation network elements. And with a small footprint, great scalability, and fully integrated multi-service interfaces, DMXplore and DMXtend simultaneously make the case for a next-generation CPE and fulfill the need.
Figure 3-27 Metropolis
®
DMX Family Converged Service
Application
DMX
plore
10/100 Mbps and/or
TDM
METRO
CO/POP
DMX
plore
OC-3/12
1+1/
UPSR
Metropolis
®
DMX
tend
OC-3/12/48
UPSR/ 1+1
Metropolis
®
DMX
DMX
plore
= Metropolis
®
DMX
plore
Access Multiplexer
®
DMX = Metropolis DMX Access Multiplexer
DMX
tend
= Metropolis
®
DMX
tend
Access Multiplexer
MA-DMXplore-019
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
Lucent Technologies – Proprietary
See notice on first page
3 - 4 3
Applications and Configurations
DSLAM Access
............................................................................................................................................................................................................................................................
Overview
The DMX provides a cost-effective aggregation and transport vehicle for digital subscriber line (DSL) or remote digital subscriber line access multiplexer (DSLAM) gateways.
Description
Application advantage
In the figure below DMX is located at a central office where it collects
DS3 and/or OC-3/OC-12/GbE signals from multiple DSLAMs, multiplexes them to the OC-48/192 line rate, and sends them out on the
OC-48/192 ring for back-haul to centrally located ATM switches that can be used more cost-effectively than distributed ATM switches.
Figure 3-28 DSLAM Application
DSLAM
DSLAM
DS3, OC-3,
OC-12 (A
TM)
DS3, OC-3,
OC-12 (ATM)
DSLAM
(Ether
Edge POP
RT
Metropolis
DMX
Metropolis
DMX
®
®
OC-48/OC-192 UPSR
Voice
Switch
Data Hub
Metropolis
®
DMX
DS3,
OC-3/12
(high-fill)
Core
Switch
DS3,
OC-3
(low-fill)
Edge
Switch
OC-12
DSI/
Voice
Multiservice
DSLAM
DS3, OC-3,
OC-12 (ATM)
DSLAM nc-dmx-012
A DMX offers a cost-effective, scalable access network infrastructure for DSL access transport.
...........................................................................................................................................................................................................................................................
3 - 4 4
Lucent Technologies – Proprietary
See notice on first page
365-372-300
Issue 8.0 September 2006
Applications and Configurations
TransMUX Functionality with LNW18/20
............................................................................................................................................................................................................................................................
Overview
The DMX provides a cost-effective/ bandwidth preserving aggregation and transport vehicle for DS1 signals. Using the LNW18 (12 ports) or
LNW20 (48 ports), DMX can combine multiple DS1 signals into a channelized DS3 for more efficient transport through/to the core network.
Description
In the figure below DMX is pictured collecting multiple DS1s around the UPSR and, in the node at the far right of the figure, transmitting them within a channelized DS3 signal back to the core network. This
TransMUX capability is provided by the TransMUX circuit packs located in the DMX at the far right of the picture.
Figure 3-29 TransMUX Application
7 DS1s on
STS-1 #1 to IEC
Metropolis
®
DMX
Metropolis
®
DMX
OC48/192
UPSR
Metropolis
®
DMX
1 DS3 to IEC
Transmux CPs are only required here
10 DS1s on
STS-1 #2 to IEC
Metropolis
®
DMX
10 DS1s on
STS-1 #3 to IEC nc-dmx2-035
Application advantage
TransMUX functionality enables the DMX to:
• Groom DS1s for channelized DS3s
• Eliminate the need for separate M-13 MUXs at the DS1 aggregation site
• Pack DS3s with multiple DS1s to use bandwidth back to the network core most efficiently
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
Lucent Technologies – Proprietary
See notice on first page
3 - 4 5
Applications and Configurations
Enhanced TransMUX Functionality with LNW20
............................................................................................................................................................................................................................................................
Overview
The LNW20 enhances DMX TransMUX functionality by increasing capacity and supporting new configurations. LNW20 provides 48 ports supporting DS3, EC1, and TMUX services provisionable on a port-by-port basis. Each port can be individually provisioned as DS3 or
EC1 (unchannelized), or as TransMUX (channelized DS3s). With the
LNW20, one high-density pack can be used for all DS3, EC1, and/or
TransMUX applications.
Description
The figure below shows the various capabilities of the LNW20. Notice that the brackets and text at the right of the figure differentiate between legacy features and new capabilities enabled only by the LNW20.
Figure 3-30 LNW20 Capabilities
DS-3
DS-3
DS-3
DS-3
EC-1
EC-1
EC-1
(VT1.5/DS-1)
EC-1
(VT1.5/DS-1)
STS-1(VT1.5/DS-1)
STS-1(VT1.5/DS-1)
STS-1(DS-3/DS-1)
STS-1(DS-3/DS-1)
STS-1(VT1.5)
STS-1(VT1.5)
LNW18 TMUX
LNW16/LNW19
Existing
Capability
STS-1(DS-3/DS-1)
STS-1(DS-3/DS-1)
STS-1(DS-3/DS-1)
Added
Functionality via LNW20
External Internal
STS-1(VT1.5/DS-1)
STS-1 OC-n Main
STS-1 to OC-n Hairpin
STS-1 Main Fabric
VT1.5 to DS-1 Drop
VT1.5 Groomed to Multiple Interfaces
Portless
Transmux
MA-DMXAPG-054
Before the LNW20 was introduced, DMX could support TransMUX functionality on DS3 signals using the LNW18. It could also support
EC-1 signals using the LNW16/19/19B.
...........................................................................................................................................................................................................................................................
3 - 4 6
Lucent Technologies – Proprietary
See notice on first page
365-372-300
Issue 8.0 September 2006
Enhanced TransMUX Functionality with LNW20
Applications and Configurations
With the LNW20, DMX can support DS3, EC-1 TransMUX using a single card. As the figure shows, it also supports a portless mode that supports TransMUX functionality without using any of the physical interfaces on the pack (for those ports in portless mode that is).
When operating in portless mode, LNW20 pulls DS1s from channelized DS3 signals that enter DMX on a SONET STS-1 interface on another pack (at least one side of the cross-connect is OCn/EC1) and converts them to VT mapped STS-1s. This VT-mapped STS-1 is cross-connected at the VT level in the Main packs to any interface that supports the signal structure today (DS1, channelized DS3, EC1, optical).
Application advantage
Enhanced TransMUX functionality with the LNW20 enables DMX to:
• Upgrade density for TransMUX to 48 ports per pack
• Support DS3, EC-1 and TransMUX on a single pack
• Portless functionality allows DMX to cross-connect any channelized DS3 entering the shelf to any port that accepts
VT-mapped STS-1s without using the electrical interfaces on the
LNW20 itself.
• Groom DS1s for channelized DS3s
• Eliminate the need for separate M-13 MUXs at the DS1 aggregation site
• Pack DS3s with multiple DS1s to use bandwidth back to the network core most efficiently
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
Lucent Technologies – Proprietary
See notice on first page
3 - 4 7
Applications and Configurations
Network Configurations
Overview
............................................................................................................................................................................................................................................................
Purpose
DMX provides the flexibility required for operation in today’s changing telecommunications networks. With topology and capacity upgrades, a DMX network can be installed with minimum first cost and then easily grown to add new sites and services.
Network flexibility
The following sections describe some of the network topologies in which DMX can be used. Many other combinations of these network configurations can be used to meet specific network and fiber topologies.
...........................................................................................................................................................................................................................................................
3 - 4 8
Lucent Technologies – Proprietary
See notice on first page
365-372-300
Issue 8.0 September 2006
Overview
Contents
Applications and Configurations
Network topologies discussed in this section include:
Increased Span Length: External DWDM Optical Amplifiers
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
Lucent Technologies – Proprietary
See notice on first page
3 - 4 9
Applications and Configurations
Path Switched Rings
............................................................................................................................................................................................................................................................
Overview
This section describes the unidirectional path switched ring configuration available with the DMX.
Purpose of path switched rings
The need to prevent service outage caused by network failure has created path switched ring applications. The path switched rings configuration provided by DMX is a self-healing network that automatically protects against service outages caused by cable cuts and equipment failures, which in turn protects customer traffic and increases revenue opportunity.
DMX path switched rings operate in an easily-managed, integrated, single-ended fashion. Restoration is fast and reliable. Complex network-level coordination is not necessary to restore traffic.
Furthermore, bandwidth administration and network reconfigurations
(for example, adding or deleting nodes) are simple because path switching does not require special time slot assignment rules.
Typical path switched ring application
A network that requires the majority of its traffic to be dropped at a single node is an ideal application for path switched rings. A typical access network, where most traffic is between the customer locations and a point-of-presence (POP) or end office, fits this mold. Such an application calls for reliable delivery between customers and POPs. In cases where a mixture of wideband and broadband services is required, a DMX path switched ring is ideal.
OC-3/12/48/192 path switched rings
The OC-12/48/192 path switched ring allows several remote sites to share the two-fiber ring facility back to the CO. DMX interfaces to the ring through the Main slots at the OC-12/48/192 rate and uses its programmable VT1.5/STS-1/STS-3c/STS-12c/STS-48c cross-connect capability. Path switching can be done on VT1.5, STS-1, STS-3c,
STS-12c, or STS-48c paths, or a mixture of these, and all can be added/dropped from the DMX path switched ring at any node. Using the ring’s path protection scheme, time slots are reserved all the way around the ring. Cross-connections offer full flexibility in assigning signals between low-speed ports and the high-speed interface at each node. DMX can easily adapt to unpredicted growth at a ring node.
OC-3/12/48 UPSRs are supported on the low speed (tributary) interfaces with the same characteristics as the high speed UPSRs
...........................................................................................................................................................................................................................................................
3 - 5 0
Lucent Technologies – Proprietary
See notice on first page
365-372-300
Issue 8.0 September 2006
Path Switched Rings
Applications and Configurations
described above. DMX supports path switching on STS-1, STS-3c,
STS-12c, STS-48c, and VT1.5 paths only.
Ring topology
The ring topology routes traffic between a CO site and a set of remote sites, or between multiple COs, while providing complete protection. In addition, only two OLIUs are needed per DMX, which provides a cost savings. Traffic can also be routed between remote nodes. The ring can start with as few as two nodes and grow to support many nodes through in-service node additions.
For protection against a CO failure, it may be desirable to include a second CO node in the ring. DMX’s support for dual homing architectures allows all services to be routed to the alternate CO while the first CO is out of service.
Operation
The DMX OC-3/12/48/192 path switched ring operates as shown in
Figure 3-31 (3-52). Traffic entering a path switched ring node is sent
onto both rotations of the ring. At the receiving node, the signal having the highest integrity (based on SONET path information) is selected and dropped as outgoing traffic. At intermediate nodes, the traffic is
“passed-through” without changing the SONET path information. The
DMX VT1.5/STS-1/STS-3c/STS-12c/STS-48c cross-connect capabilities make the provisioning of add/drop and pass-through traffic quick and easy.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
Lucent Technologies – Proprietary
See notice on first page
3 - 5 1
Path Switched Rings
Applications and Configurations
The self-healing nature of the path switched ring is shown in Figure
3-31 (3-52) (b). In this case, the fiber failure between nodes C and D
causes node C to switch from the counterclockwise ring to the clockwise ring, thus maintaining service between all nodes on the ring.
Figure 3-31 Path Switched Rings
AC CA AC CA
Node A
Node D Node B
Node C
Node A
Node D Node B
Node C
Switch
Made
AC CA AC CA nc-dmx2-028
Configuration advantage
Path switched rings are the industry standard for self-healing networks, providing reliable transport for access networks while accommodating almost any type of application.
...........................................................................................................................................................................................................................................................
3 - 5 2
Lucent Technologies – Proprietary
See notice on first page
365-372-300
Issue 8.0 September 2006
Applications and Configurations
2-Fiber BLSRs
............................................................................................................................................................................................................................................................
Overview
Traffic capacity
A 2-fiber bidirectional line-switched ring (BLSR) is a self-healing ring configuration in which bidirectional traffic travels over the same set of nodes in each direction. Bidirectional switching makes use of redundant (protection) bandwidth on the bidirectional lines that interconnect the nodes in the ring to provide protection for traffic carried on the working bandwidth. Because the traffic is bidirectional, a single circuit does not necessarily consume bandwidth on every span in the ring. This leaves the spans between other nodes available for additional traffic. Therefore, with distributed switching patterns, a
BLSR can carry more traffic than the same facilities could carry if configured for a unidirectional path-switched ring.
The DMX supports one high-speed OC-48 2-fiber BLSR or two high-speed OC-192 2-fiber BLSR and 14 low-speed OC-48 BLSRs. In the latter application, the low-speed OC-48 BLSR(s) is hosted by
OC-48 circuit packs housed in the Function slots and can add and drop traffic with the high-speed OC-192/48 circuit packs housed in the Main slots. Low-speed OC-48 BLSRs can also add and drop traffic with interfaces in other tributary (low-speed) slots (includes both Function
Units and Growth slots).
The following figure shows working and protection traffic capacities in an OC-192 2-fiber BLSR. The OC-48 2-fiber BLSR operates in the same way, but has 48 STS-1 timeslots in each direction, 24 for working traffic and 24 for protection.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
Lucent Technologies – Proprietary
See notice on first page
3 - 5 3
2-Fiber BLSRs
Applications and Configurations
Figure 3-32 Traffic Capacity in an OC-192 2-Fiber BLSR
Working 1
Protection 2
Working 2
Fiber 1
Timeslots 1-96
Timeslots 1-96
Timeslots 97-192
Protection 1
Timeslots 97-192
Fiber 2
Metropolis
®
DMX
Metropolis
®
DMX
Protection 2
Working 1
Protection 1
Working 2
Fiber 2
Timeslots 97-192
Timeslots 1-96
Timeslots 97-192
Timeslots 1-96
Fiber 1 nc-dmx-109
Self-healing rings
DMX 2-fiber BLSRs are self-healing in that transport is automatically restored after node or fiber failures. Each OC-192 line carries 96 STS-1 equivalent timeslots of working capacity plus 96 STS-1 equivalent timeslots of protection capacity. Each OC-48 line carries 24 STS-1 equivalent timeslots of working capacity plus 24 STS-1 equivalent timeslots of protection capacity. In the event of a fiber or node failure, service is restored by switching traffic from the working capacity of the failed line to the protection capacity in the opposite direction around the ring (see the figure below and the figure on the following page.). In the event of a node failure, traffic added and dropped from the failed node is not protected by line switching.
...........................................................................................................................................................................................................................................................
3 - 5 4
Lucent Technologies – Proprietary
See notice on first page
365-372-300
Issue 8.0 September 2006
2-Fiber BLSRs
Applications and Configurations
2-fiber BLSR traffic flow
The figure below shows normal (non-protection-switched) traffic flow on a 2-fiber BLSR.
Figure 3-33 Normal Traffic Flow in a 2-Fiber BLSR
Working 1
Protection 2
Working 2
Protection 1
Node B
DMX
Node A Node C
DMX DMX
DMX
Node E
DMX
Node D
Protection switching
When a line failure triggers a protection switch, the nodes adjacent to the failure switch traffic on to protection capacity. Traffic heading toward the failure is looped back on to the protection capacity traveling away from the failure to reach its destination by traveling the opposite way around the ring (see the figure below). Service is reestablished on the protection capacity in
≤
50 milliseconds after detection of the failure
(for catastrophic failures in rings without existing protection switches or extra traffic).
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
Lucent Technologies – Proprietary
See notice on first page
3 - 5 5
2-Fiber BLSRs
Applications and Configurations
Fiber cut example
The figure below illustrates a 2-fiber BLSR protection switch that results from a fiber cut.
Figure 3-34 Loopback Protection Switch in a 2-Fiber BLSR
Working 1
Protection 2
Working 2
Protection 1
Node B
DMX
Node A Node C
DMX DMX
Protection traffic flow
DMX
Node E
DMX
Node D
Fiber Cut nc-dmx-113
In the figure above, traffic going from Node A to Node C that normally passes through Node E and Node D on “working 2” capacity is switched at Node E on to the “protection 2” capacity of the line leaving
Node E in the direction of Node A. The traffic passes through Nodes A,
B, and C on the protection bandwidth to Node D where it is looped back to Node C. Similarly, traffic going from Node C to Node A that normally passes through Node D and Node E on “working 1” capacity is switched at Node D on to the “protection 1” capacity of the line leaving Node D in the direction of Node C. The traffic passes through
Nodes C, B, and A on the protection bandwidth to Node E where it is looped back to Node A. Note that only the nodes adjacent to the failure perform loopback protection switches. The same approach is used for a node failure. For example, if Node D fails, Nodes C and E perform loopback protection switches to provide an alternate route for ring traffic. However, traffic that is added and dropped at the failed node,
Node D, cannot be protected by ring switching and is therefore squelched at the switching nodes.
...........................................................................................................................................................................................................................................................
3 - 5 6
Lucent Technologies – Proprietary
See notice on first page
365-372-300
Issue 8.0 September 2006
Applications and Configurations
Packet Rings
............................................................................................................................................................................................................................................................
Overview
Packet Ring configurations provide business-to-business networking of routers and data switches using Ethernet transport over a reliable, low-cost multiservice network. The DMX provides the unique capability for a packet ring to span multiple ring topologies. As shown in the figure below packet rings hosted by the DMX can span multiple
OC-192, OC-48, OC-12, OC-3 ring configurations (UPSRs or BLSRs).
Additionally, packet rings hosted by the DMX can reach into areas serviced by dual and single-homed ring extensions (see the figure below).
Ethernet over SONET
A Packet Ring is a set of packet switches connected in a ring topology that use the inherent redundancy of the ring configuration to provide durability and fast restoration in the event of failures.
Packet rings can be used with or without SONET layer protection. At the packet layer, the rapid spanning tree protocol (as defined in IEEE
802.1) is used to provide protection.
Figure 3-35 Packet Rings
DMX
100/1000M
Ethernet
Switch/
Router
Switch/
Router
100/1000M
Ethernet
DMX
DMX
OC-48/192
DMX
DMX
OC-48
CO/Regional
Hub
DMX
ISP
Router
Ethernet
OC-48
DMX
10/100/1000M bps Ethernet
Application
Server
Switch/
Router
®
DMX = Metropolis DMX Access Multiplexer nc-dmx2-014
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
Lucent Technologies – Proprietary
See notice on first page
3 - 5 7
Packet Rings
Applications and Configurations
DMX uses standard Generic Framing Procedure (GFP) encapsulation
(ITU G.7041) for Ethernet over SONET mapping. Packet rings provide efficient aggregation and transport for Ethernet traffic. DMX’s virtual concatenation capability (ITU G.707) provides flexible bandwidth granularity in the wide area network (WAN), which can grow with your service demand.
Packet Rings over a BLSR
DMX allows the manual provisioning of non-preemptable unprotected traffic (NUT) for multi-point Ethernet cross-connections that originate on low-speed (tributary) interfaces and share bandwidth on the high-speed (Network side) BLSR ring.
When using multi-point cross-connections through a BLSR, packets do not receive standard BLSR protection due to the necessary functioning of NUT. Yet, protection on all data packets is provided for with rapid spanning tree protocol (IEEE 803.1w).
Packet Ring Capacity
DMX supports the following number of packet rings per Ethernet interface circuit pack:
• 1 packet ring on each 10/100 Mbps Fast Ethernet circuit pack
(LNW66, LNW71, and LNW74)
• 2 packet rings on each 1000 Mbps GbE circuit pack (LNW67 and
LNW68)
• 16 packet rings on each 10/100/1000 Mbps GbE circuit pack
(LNW70)
• 2 packet rings on each RPR circuit pack (LNW78)
Specific Applications
Supported
DMX supports the following enterprise LAN (local area network) interconnect and transport applications:
• Ethernet Private Line
• Ethernet Rate Shaping Services
• Virtual LAN Services
• Transparent LAN Services
• Best Effort Service
• Ethernet/TDM Access to Frame Relay or ATM Network
• Ethernet/TDM Access to IP Network
• DSLAM Access
Each of these packet ring applications are detailed in the “Service
Applications” section of this chapter.
...........................................................................................................................................................................................................................................................
3 - 5 8
Lucent Technologies – Proprietary
See notice on first page
365-372-300
Issue 8.0 September 2006
Applications and Configurations
DWDM Optics
............................................................................................................................................................................................................................................................
Overview
Metropolis
®
DMX Access Multiplexer supports low-cost DWDM optics. These optics include 16 different OLIUs (2 wavelengths per
OLIU) for OC-48 transmission, and a choice of 5 different Passive
Optics Units (POUs) where the various wavelengths are combined for transmission over one fiber. The DWDM wavelengths or channels are chosen at 100 GHz increments per the ITU grid.
In R4.0, DMX also supports 3 OC-192 DWDM circuit packs that feature “tunable” lasers. The optics on each pack can be tuned to any one of four separate frequencies to provide a flexible range of DWDM frequencies that enable each circuit pack to serve in four different
DMX DWDM systems. This makes each pack more versatile, reusable, and efficient in DWDM applications. The LNW523, LNW527, and
LNW554 are the circuit packs featuring tunable optics.
Port units
DMX OC-48 DWDM OLIUs are available in 32 different wavelengths.
Each port unit is capable of transmitting 2 different wavelengths (1 wavelength at a time). These units are compatible with the SONET standards.
The DWDM OLIUs are designed to be used with the Lucent POUs. By using the DWDM OLIUs and the POUs, you are able to increase fiber from 1 to 32.
Passive optics units
As the variety of applications listed above suggests, there are various versions of the POU, each designed to maximize functionality in a variety of deployment scenarios. The bulleted list below details the various forms of POUs:
• 16 Channel MUX or DMUX (odd numbered channels): This POU supports unidirectional and bidirectional transmission systems.
• 16 Channel MUX or DMUX with Interleaver (even numbered channels): This POU supports unidirectional and bidirectional transmission systems, and includes an interleaver to support 16 additional channels.
• Dual 1-Channel Optical Add Drop: This POU supports unidirectional transmission systems and can add/drop one channel from a DWDM line carrying up to 32 different channels.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
Lucent Technologies – Proprietary
See notice on first page
3 - 5 9
DWDM Optics
Applications and Configurations
• Dual 2-Channel Optical Add Drop: This POU supports unidirectional transmission systems and can add/drop two channels from a DWDM line carrying up to 32 different channels.
• Dual 4-Channel Optical Add Drop: This POU supports unidirectional transmission systems and can add/drop four channels from a DWDM line carrying up to 32 different channels.
• Dual 1310 + 4x1550 MUX/DMUX: This POU provides one I/O port for 1310 nm signals and four I/O ports for 1550 nm signals.
This POU supports unidirectional transmission systems and can
MUX or DMUX a 1310 channel and four 1550 bands to/from a
DWDM line.
Important!
The last four bulleted items in the list above describe the various OADMs and MUX/DMUX as “Dual”.
“Dual” is in reference to the fact that each of these specific POUs are comprised of two complete sets of OADMs or MUX/DMUX units. Thus, the dual 1-channel OADM POU contains 2 OADMs interfaces, enabling it to support 1 add/drop in each direction.
Protection
The passive optic port units support the same protection modes as the standard port units. For example, both sets of passive port units support
BLSR, UPSR, and 0x1 protection. The DWDM passive OLIUs also support 1+1 protection.
MUX/DMUX Example
The figure below shows 16 lines to and from DMX systems. The
OC-48 traffic from the 8 incoming (receive) and 8 outgoing (transmit) lines is transmitted over one fiber using DWDM on the Lucent passive optics shelf to a remote Lucent passive optics shelf. The traffic is similarly transmitted and received by that system. Alternatively, the equipment can be set up to handle 16 or 32 transmit lines on one end of the passive optics unit and 16 or 32 receive lines on the other end.
...........................................................................................................................................................................................................................................................
3 - 6 0
Lucent Technologies – Proprietary
See notice on first page
365-372-300
Issue 8.0 September 2006
DWDM Optics
Applications and Configurations
Figure 3-36 Lucent Passive Optics Unit with DMX
DMX DMX
To/From other
Nodes and
Tributaries
DMX
WaveStar
2.5G/10G
2F
DMX
WaveStar
Bandwidth
Manager
OC-48/192
BLSR or UPSR
DWDM
OC-48/192
BLSR or UPSR
WaveStar
2.5G/10G
2F
DMX
WaveStar
Bandwidth
Manager
DMX
To/From other
Nodes and
Tributarie
DMX DMX nc-dmx-11
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
Lucent Technologies – Proprietary
See notice on first page
3 - 6 1
Applications and Configurations
Increased Span Length: External DWDM Optical Amplifiers (OAs)
............................................................................................................................................................................................................................................................
Overview
For OC-192 spans of up to 140km, Lucent Technologies offers DWDM optical amplifiers. The DWDM optical amplifier is a stand-alone shelf and can be used with both regular and DWDM OC-48 and OC-192 optics.
Concept
Optical amplifiers consist of one booster and one pre-amplifier part.
The booster part is connected via a Dispersion Compensation Module
(DCM) to the transmit interface of the respective OC-192 or OC-48 port unit. The pre-amplifier is connected by means of a DCM to the receive interface of the associated port unit.
Applications
The DWDM optical amplifier has two main applications:
• Single span application
• Multiple span application
A simple example for a single span application is shown in the following figure.
Figure 3-37 External Optical Amplifier Application
Office A
Transmitt Amplifier
Metropolis
®
DMX
OA
Remote Site
Line Amplifier
OA
OA
Office B
Pre-Amplifier
Metropolis
®
DMX
Nc-dmx-165
Further Information
For a description of the optical amplifier’s physical specifications, see the section entitled “External Optical Amplifier” in Chapter 4 of this document.
For a description of the optical amplifier’s optical specifications, see the section entitled “External Optical Amplifier” in Chapter 10 of this document.
...........................................................................................................................................................................................................................................................
3 - 6 2
Lucent Technologies – Proprietary
See notice on first page
365-372-300
Issue 8.0 September 2006
Applications and Configurations
Dual Node Ring Interworking
............................................................................................................................................................................................................................................................
Overview
Dual node ring interworking (DRI) is a configuration that provides path-level protection for selected STS-N circuits that are being carried through two UPSRs. Protection for the route between the two rings is
provided by interconnecting the rings at two places (see Figure 3-38
Each circuit that is provisioned with DRI protection is dual-homed, meaning it is duplicated and subsequently passed-through at two different nodes on a ring. The two interconnecting nodes in each ring do not need to be adjacent.
DRI protection
The self-healing mechanisms of the two UPSRs remain independent and together protect against simultaneous single failures on both rings
(not affecting the interconnections). The DRI configuration additionally protects against failures in either of the interconnections between the rings, whether the failure is in a facility or an interconnection node.
Ring interworking
All DMX tributary SONET interfaces (OC-3, OC-12, and OC-48) support DRI. The DMX high-speed ring can be an OC-12/48/192
UPSR. A DMX ring supports DRI with UPSRs, including rings using the following products:
• DMX
• WaveStar TDM 2.5G/10G (2-Fiber)
• WaveStar BandWidth Manager
• DDM-2000 OC-3
• DDM-2000 OC-12
• FT-2000 ADR
Additionally, there can be intermediate network elements in the interconnection routes between the two rings.
UPSR-to-UPSR interworking
In the UPSR to UPSR interworking both UPSR DRI nodes select the better of two paths travelling in the drop direction and pass traffic to one rotation of the ring in the add direction.
UPSR drop and continue
DMX supports the drop and continue method of DRI, in which both
UPSR DRI nodes select the better of two paths travelling in the drop direction and pass traffic to one rotation of the ring in the add direction.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
Lucent Technologies – Proprietary
See notice on first page
3 - 6 3
Applications and Configurations
UPSR to UPSR protection switching example
Each node drops the circuit in the direction of the other ring and a pass-through circuit to the other DRI node is made. The best of the 2 resulting signals is dropped at the terminating node of the new ring.
The figure below illustrates a failure of the interconnection to a DRI node at the point labeled “X” in the figure. A failure in the route from
Node A to Node Z results in a path switch at the surrounding nodes adjacent to the failure. The DRI nodes themselves will only perform the protection switch if they are the nodes adjacent to the failure. As you can see, while all nodes and lines remain fully functional, DRI functions as described in the section above. Both DRI nodes in the top ring select the best of the 2 signals received from that ring, and transmit them to the DRI nodes in the lower ring. The best of the signals received at the terminating node is dropped.
A path protection switch in a DMX occurs in <50 milliseconds (not counting the detection time) at the nodes adjacent to any failure.
Figure 3-38 Dual Ring Interworking Protection
A
Primary
Nodes
X
X
Z
A
Secondary
Nodes
Z
1. DRI configurations: two rings interconnected by two nodes
2. Circuit originating and terminating in
Nodes A and Z
3. Failure (depicted by x) triggers
DRI switch at primary nodes, which automatically selects traffic from secondary nodes
NC-DMX-149
...........................................................................................................................................................................................................................................................
3 - 6 4
Lucent Technologies – Proprietary
See notice on first page
365-372-300
Issue 8.0 September 2006
Applications and Configurations
Single and Dual-Homing
............................................................................................................................................................................................................................................................
Overview
End users are demanding service with high availability. Service providers are responding with tariffs that rely on self-healing networks to offer high availability service. Some of these tariffs even call for penalties for the service provider when service is interrupted or has a high error rate. The Lucent SONET product family offers many options for meeting these service needs. One of these, OC-3/12/48 ring transport on DMX ring networks, can be implemented in single- and dual-homing configurations.
For lower-density TDM applications, DMX can provide an OC-3/12/48 optical ring termination for a DDM-2000 OC-3 Multiplexer,
DDM-2000 OC-12 Multiplexer, DDM-2000 FiberReach, or any other compliant network element. This feeder ring is useful for evolving lower-density access transport applications into high-rate access networks.
Description
The figure below shows a dual-homed OC-3 extension from two remote nodes on a DMX access ring. OC-3 extensions from DMX rings are available when the DMX Function Unit groups are equipped with
OC-3 OLIU circuit packs. OC-12/48 extensions from DMX rings are also available. The host nodes must be DMX NEs. For an example of single homing, see the following page.
Figure 3-39 Dual Homing Example
CO
WBDCS/
DMX
WaveStar
®
BWM/TDM
10-G
OC-48/192 UPSR
Metropolis
®
DMX
DS1,DS3,
OC-3(c)/12(c)/48(c)
Metropolis
®
DMX
OC-3/12
Hub/RT
DS1,DS3,
OC-3(c)/12(c)/48(c)
0x1 rings
DDM-2000
OC-3/FiberReach
Customer
Location
DS1/DS3/OC-3(c) nc-dmx-011
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
Lucent Technologies – Proprietary
See notice on first page
3 - 6 5
Single and Dual-Homing
Applications and Configurations
Description (continued)
The figure below provides an example of both single and dual-homing.
Path protection switching is employed for dual-homed and single-homed applications in the same manner. That is, 50 millisecond path switching is supplied by the remote DDM-2000
OC-3/OC-12/FiberReach nodes and the DMX systems. The DMX host node dual homing configuration differs from that used for single-homing because each host node transports only one leg of the
OC-3/OC-12/OC-48 extension. At each host node, a connection is made from the single OC-3/OC-12/OC-48 extension to just one rotation of the DMX host ring. Dual- and single-homed extensions can also be mixed at a host node, allowing the access network to be tailored efficiently to different groups of customers. Host nodes could also be
DMXtends.
Figure 3-40 Multinode OC-3/OC-12 Ring with OC-48 Ring
Transport
DDM
DDM OC-3/12/48
UPSR
Metropolis
®
DMX
Metropolis
DMX
®
OC-12/48/192
UPSR
Metropolis
®
DMX
DDM
Single
Homed
OC-3/12/48
Ring
DDM
Metropolis
®
DMX
Metropolis
®
DMX
DDM
DDM
Dual
Homed
OC-3/12/48
Ring
DDM
DDM nc-dmx2-027
Configuration advantage
The DMX provides a seamless transmission and operations integration with lower-capacity ring networks, as well as increased scalability for those established networks. So, single and dual-homing provide additional topological flexibility in UPSR configurations supporting voice and data services.
...........................................................................................................................................................................................................................................................
3 - 6 6
Lucent Technologies – Proprietary
See notice on first page
365-372-300
Issue 8.0 September 2006
Applications and Configurations
Hairpinning
............................................................................................................................................................................................................................................................
Overview
The DMX supports both inter-function group, intra-function group, intra-port as well as pass-through hairpinning cross-connections. These capabilities allow you to route traffic in and out of the DMX system without consuming bandwidth on the high-speed (OC-12/48/192)
UPSR interfaces, and to host multiple rings on the low-speed interfaces of the DMX shelf (OC-48, OC-12, OC-3).
Inter-function group hairpin
In a “hairpinning” topology, low-speed tributary traffic is routed into the system and back out of the system without ever being placed on the high-speed (OC-12/48/192) UPSR interfaces (this description assumes that the MAINs are provisioned for UPSR protection, but intra-function group hairpins are supported on all MAIN application/protection schemes). The cross-connection capability of connecting any input on a circuit pack in a function or growth slot to any output on a circuit pack in a different function or growth slot of the same shelf allows you to use a combination of add/drop and hairpinning of compatible payloads through a variety of interfaces. You can bring traffic in from one remote site and cross-connect it at the VT, STS-1, STS-3c, STS-12c, or
STS-48c level back out to other remote sites without consuming any capacity on the high-speed UPSRs.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
Lucent Technologies – Proprietary
See notice on first page
3 - 6 7
Hairpinning
Applications and Configurations
The figure below demonstrates a topology in which traffic is hairpinned among OC-12 and OC-3 low-speed interfaces (OC-48 also an option).
For instance, a signal dropped from the OC-3 UPSR in the bottom left of the figure can travel out of the DMX on the OC-12 UPSR on a completely different tributary.
Figure 3-41 Inter-function group hairpin
A
PWR
OC-12/48/192
UPSR
B
PWR
OC-3
OLIU
FAULT
ACTIVE
OC-3
OLIU
FAULT
ACTIVE
OC-12
OLIU
FAULT
ACTIVE
OC-12
OLIU
FAULT
ACTIVE
OUT IN OUT IN
OUT IN OUT IN
1G SX OC-48
OLIU
FAULT
ACTIVE
FAULT
ACTIVE
OUT IN OUT IN
FAULT
CR
MJ
MN
ABN
FE
NE
ACO
ACO
TST
IND
SEL
UPD
INT
LAN
RS232
OC-48
OLIU
FAULT
ACTIVE
OUT IN
28DS1
FAULT
ACTIVE
28DS1
FAULT
12DS3/
EC1
FAULT
12DS3/
EC1
FAULT
ACTIVE ACTIVE ACTIVE
DDM-2000
A1 A2 B1 B2
OC-3
UPSR
OC-12
UPSR
G1 M1 CTL
Fiber Tray
G2
DDM-2000
DDM-2000
Metropolis
®
DMX press
M2 C1 C2 D1 D2 nc-dmx-018
...........................................................................................................................................................................................................................................................
3 - 6 8
Lucent Technologies – Proprietary
See notice on first page
365-372-300
Issue 8.0 September 2006
Hairpinning
Applications and Configurations
Low-speed Ring closure
The DMX can host multiple rings on the low-speed interfaces of the
DMX shelf. This is accomplished by either protected drops from a
UPSR or UPSR pass-throughs. The DMX can close a low-speed ring by supporting a cross-connection between a receive port on one circuit pack and a corresponding transmit port on another companion circuit pack in the same function or growth group (cross-connections can also be made to ports in any other slot on the shelf). All protection switching advantages/capabilities of UPSR configurations still apply in the low-speed ring closure application shown below.
The figure below demonstrates a ring closure topology in which both an OC-3 or OC-12 ring is being hosted on the low-speed interfaces alone. Notice that this consumes no bandwidth on the OC-48, high-speed UPSR in the top of the figure.
Figure 3-42 Low-speed ring closure
A
PWR
OC-12/48/192
UPSR
B
PWR
OC-3
OLIU
FAULT
ACTIVE
OC-3
OLIU
FAULT
ACTIVE
OC-12
OLIU
FAULT
ACTIVE
OC-12
OLIU
FAULT
ACTIVE
OUT IN OUT IN
OUT IN OUT IN
1G SX OC-48
OLIU
FAULT
ACTIVE
FAULT
ACTIVE
OUT IN OUT IN
FAULT
CR
MJ
MN
ABN
FE
NE
ACO
ACO
TST
IND
SEL
UPD
INT
LAN
RS232
OC-48
OLIU
FAULT
ACTIVE
OUT IN
28DS1
FAULT
ACTIVE
28DS1
FAULT
12DS3/
EC1
FAULT
12DS3/
EC1
FAULT
ACTIVE ACTIVE ACTIVE
A1 A2 B1 B2 G1 M2 C1 C2 D1 D2 M1 CTL
Fiber Tray
G2
DDM-2000
OC-3/12/48
UPSR
OC-3/12/48
1+1
DDM-2000
DDM-2000
DDM-2000 nc-dmx2-013
Intra-function group hairpin
DMX supports intra-function group, hairpin cross-connections that are cross-connections between different tributaries on different ports within the same function group. Again, the application above could be enabled by either intra-function group hairpins or UPSR pass-throughs.
Intra-function group hairpins are available in all protection schemes, not just in UPSR applications.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
Lucent Technologies – Proprietary
See notice on first page
3 - 6 9
Hairpinning
Applications and Configurations
Intra-port hairpin
DMX supports the provisioning of intra-port cross connection on
UPSR interfaces. Intra-port characterizes cross connections between channels/timeslots/tributaries hosted on the same port.
...........................................................................................................................................................................................................................................................
3 - 7 0
Lucent Technologies – Proprietary
See notice on first page
365-372-300
Issue 8.0 September 2006
Applications and Configurations
Linear Optical Extensions
............................................................................................................................................................................................................................................................
Overview
An additional topological flexibility offered by the DMX is 1+1 protected linear OC-3, OC-12, OC-48, OC-192 optical extensions from the DMX ring. Using this capability, DMX can support many of the new network configurations desired in evolving access networks.
Description
An access provider can use linear optical extensions from an
OC-12/48/192 ring to provide OC-3, OC-12, and OC-48 signals directly to end users. This gives the end users the bandwidth they need for large bandwidth applications, such as video, data, and ATM.
Linear optical extensions can also be used to interconnect SONET subnetworks. Examples include interconnection of two access networks and interconnection between access and interoffice rings.
Optical extensions can be used to interconnect DMX ring networks to an OC-3, OC-12, or OC-48 terminal, an OC-3, OC-12, OC-48, or
OC-192 add/drop network, or another OC-3, OC-12, OC-48, or
OC-192 ring. Intra-port hairpins are supported on 1+1 protected interfaces.
The figure below shows a DMX OC-48/OC-192 path switched ring with OC-3/OC-12/OC-48 services using linear optical extensions.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
Lucent Technologies – Proprietary
See notice on first page
3 - 7 1
Linear Optical Extensions
Applications and Configurations
Figure 3-43 Linear Optical Extensions
Customer Location
Customer Location
OC-3/12/48
Broadband
Terminal
Central Office
OC-3/
OC-12
Metropolis
®
DMX
DDM-2000
OC-3
DS1/DS3/EC-1
OC-3
DDM-2000
OC-3
DS1/DS3/EC-1
DS1/DS3/EC-1
OC-3/
OC-12/
OC-48
DS3/EC-1 Remote Terminal
Metropolis
®
DMX
Metropolis
®
DMX
OC-48/OC-192
UPSR or BLSR
DS3/EC-1
DS3/EC-1
Remote Terminal
OC-3/
OC-12
Metropolis
®
DMX
FT-2000 or
2.5G/10G
(2-Fiber)
DS3/EC-1
Central Office nc-dmx-010
Configuration advantage
Optical extensions from a DMX ring provide fast, reliable transport of voice, video, data, and ATM directly to end users when fiber topologies warrant protected linear (rather than ring) connections.
...........................................................................................................................................................................................................................................................
3 - 7 2
Lucent Technologies – Proprietary
See notice on first page
365-372-300
Issue 8.0 September 2006
Applications and Configurations
Hubbing
............................................................................................................................................................................................................................................................
Overview
The DMX hubbing topology provides metropolitan-area and regional-area network infrastructures based on a single NE.
Description
A DMX high-speed UPSR ring can serve as a core feeder ring, transporting voice and data from metropolitan networks to the optical core network and vice versa.
As shown in Figure 3-28, one DMX node is configured as a core feeder node, providing a conduit from the optical core to the OC-48/192 access network. On the ring, another DMX is configured as the hub node, where several DMX and DDM UPSR rings are terminated. The hub node grooms the traffic and cross-connects it to the appropriate ring.
One DMX can be configured as a hub node for up to 80 OC-3 rings, 40
OC-12 rings, 20 OC-48 rings, or, as pictured below, a mixture of high- and low-speed rings.
Figure 3-44 Hubbing Application
Metropolis
®
DMX
press
DDM-2000
DMX
OC-48
OC-3/12
CO/Hub
Node
DMX
DMX OC-48
OC-12
Metropolis
®
DMX
press
DDM-2000
DDM-2000
®
DMX = Metropolis DMX Access Multiplexer
CO
DMX
OC-48/192
UPSR
DMX
CO
DMX
Metro
Core
Optical
Core
NC-DMX-155
Configuration advantage
Hubbing provides high-capacity, low-cost grooming between multiple optical rings. It also provides greater flexibility and efficiency in serving large numbers of customers on multiple fiber rings.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
Lucent Technologies – Proprietary
See notice on first page
3 - 7 3
Hubbing
Applications and Configurations
...........................................................................................................................................................................................................................................................
3 - 7 4
Lucent Technologies – Proprietary
See notice on first page
365-372-300
Issue 8.0 September 2006
4 Product Description
Overview
............................................................................................................................................................................................................................................................
Purpose
This chapter provides a detailed view of the DMX Access Multiplexer architecture. After introducing the DMX shelf, this chapter describes the system circuit packs, control, power, and cabling.
Contents
The following hardware is described in this chapter:
DMX 20 Amp Shelf Power Specifications
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
4 - 1
Product Description
Shelf Description
............................................................................................................................................................................................................................................................
Overview
The DMX is a single-shelf multiplexer that may house DS1/E1, DS3/
EC1, TransMUX, OC-3, OC-12, OC-48, OC-192, 10/100T (optical and electrical), 1G TX/SX/LX/ZX, and SAN (FICON/ESCON/FC) circuit packs.
Size
When equipped with VLF Mains (LNW59), each Function Unit and
Growth slot in the DMX shelf has a 10 Gb/s IO capacity. The LNW59
VLF Main increases the capacity of the Main slots to 20 Gb/s.
When VLF Mains are not used, each Function Unit slot in the DMX shelf has a 2.5 Gb/s IO capacity. The Growth slots have 5 Gb/s capacity, and the Main slots have 10 Gb/ps. Up to four DMX systems can fit in a bay, and all shelves are individually mounted.
The High-Capacity shelf also has the following characteristics:
• Width: 17.6 inches
• Height: 19 inches (includes integral fan unit)
• Depth (front to back): 13.75 inches (all optical applications only: without back cover and interface connectors*)
• Weight (with circuit packs): 57 pounds
• Weight (without circuit packs): 38 pounds
Important!
*: 15 inches with interface connectors, 16 inches with connectors and cover.
Up to four DMX high capacity shelves can fit in a bay (including integral fan unit), and all shelves are individually mounted.
The DMX high capacity shelf is available with 30 amp circuit breakers or 20 amp circuit breakers.
High Capacity Shelf
The high capacity shelf can operate using any release of DMX software.
This new design incorporates additional DS1/DS3 D-SUB cable connectors on the rear of the shelf that enable the DMX to support 224
DS1/E1s or 192 DS3/EC-1s. In order to support this amount of traffic, the DMX high capacity shelf must be equipped with new, higher density DS1/E1 and DS3/EC-1 circuit packs.
All other existing and future electrical, optical, Ethernet, and SAN circuit packs can also be used in the high capacity shelf.
...........................................................................................................................................................................................................................................................
4 - 2
365-372-300
Issue 8.0, September 2006
Shelf Description
Product Description
Interface Density
DMX provides a VT1.5 and STS-1 cross-connect fabric. DMX’s main switch fabric is contained in each of the high-speed (network-side interface) circuit packs, located in the MAIN slots. The MAIN slots house OC-12, OC-48, and OC-192 high-speed interfaces. They can also house the LNW80 switch pack. The LNW59 VLF Main enables
0x1 Fn/Growth slot equipage beginning in R7.0. In many cases, this doubles the overall capacity of the shelf.
The table below details the maximum number of signals that DMX can transport if all Function Unit (and Growth Slots where applicable) groups are equipped with a particular circuit pack (for example, 80
1000BASE-SX/LX/ZX ports if both slots in all four Function Unit and
Growth groups are equipped with the LNW64 circuit packs (this 0x1 configuration requires VLF Main packs).
Table 4-1 Interface Densities
Interface Type
DS1/E1
DS3/EC-1
TransMUX
OC-3
OC-12
OC-48
OC-192
192
80
40
40
Capacity/Main Switch
VLF
(0x1 equipped)
Large/
Medium
Fabric
224
192
224
192
4
192
80
40
10
2
Comments
Electrical TDM packs, and other packs that require rear access, do not support true 0x1, hence, overall capacity does not increase with VLF Mains
192 capacity requires the 48 port LNW20
80 unprotected, 40 protected
40 unprotected, 20 protected
40 capacity requires LNW62, only supported on VLF equipped shelves. 40/10 unprotected, 20/5 protected
4 capacity requires LNW59. LNW59 provides 2 OC-192 ports. 4 unprotected with LNW59 only, 2/1 protected
100BASE-TX
100BASE-LX (optical)
1000BASE-SX/LX/ZX
1000BASE-TX
FICON/ESCON/
Fibre-Channel
96
80
80
80
40
96
40
20
20
20
Larger capacities associated with VLF Mains require 0x1 equipage in all slots, only supported in R7.0 and later releases.
365-372-300
Issue 8.0, September 2006
DMX also provides STS-1 virtual concatenation. STS-1 VCAT increases flexibility when managing Ethernet services. Each
............................................................................................................................................................................................................................................................
4 - 3
Shelf Description
Product Description
10/100BASE-TX/PL and 1000BASE-SX/LX/ZX Ethernet service can be provisioned to any number of STS-1s (up to 21 STS-1s per VCG).
This is true for all Ethernet packs except LNW71. The LNW71 and
LNW74 can accept 1 or 2 STS-1s or a single STS-3c per port. The
LNW73/73C provides STS-1 and STS-3c virtual concatenation.
...........................................................................................................................................................................................................................................................
4 - 4
365-372-300
Issue 8.0, September 2006
Shelf Description
Front view
Product Description
The figure below shows the front of the DMX shelf equipped with the following:
• 28DS1 circuit packs in Function Unit group A
• 12DS3/EC1 circuit packs in Function Unit group B
• Quad OC-3 circuit packs in Function Unit group C
• Dual OC-12 circuit packs in Function Unit group D
• 1G SX circuit pack in Growth slot G1
• an apparatus blank in Growth slot G2
• OC-48 circuit packs in Main slots 1 and 2
• LNW2 SYSCTL circuit pack in the CTL slot.
Note that high-speed OC-192, OC-12, and the LNW80 (headless switch pack) network interface OLIUs are not pictured, but could populate Main slots 1 and 2. Many other tributary packs are not
pictured either. For pack-specific slot equipage rules refer to
Circuit pack slots and compatible circuit packs
Figure 4-1 Shelf Front View
a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa
LNW6
Sx:x
LUCENT
LNW6
Sx:x
LUCENT
LNW16
Sx:x
LUCENT
LNW16
Sx:x
LUCENT
LNW67
Sx:x
LUCENT
LNW26
Sx:x
LUCENT
LNW1
Sx:x
LUCENT
177D
Sx:x
LUCENT
LNW26
Sx:x
LUCENT
LNW36
Sx:x
LUCENT
LNW36
Sx:x
LUCENT
LNW46
Sx:x
LUCENT
LNW46
Sx:x
LUCENT
Heat Baffle
FAULT
ACTIVE
28DS1
FAULT
ACTIVE
28DS1
FAULT
ACTIVE
FAULT
ACTIVE
12DS3/
EC1
12DS3/
EC1
FAULT
ACTIVE
1G SX
FAULT
ACTIVE
OC-48
OLIU
OUT IN
1
2
OUT IN
FAULT
CR
MJ
MN
ABN
FE
NE
ACO
ACO
TEST
IND
SEL
UPD/
INT
LAN
CIT
RS
232
177D
BLANK
FAULT
ACTIVE
OC-48
OLIU
FAULT
ACTIVE
OC-3
OLIU
OC-3
OLIU
OUT IN OUT IN
FAULT
ACTIVE
FAULT
ACTIVE
OC-12
OLIU
FAULT
ACTIVE
OC-12
OLIU
OUT IN 1 1
2 2
OUT IN OUT IN
1 1
3
4
3
4
2 2
A1 A2
Lucent Technologies
Metropolis
®
DMX
B1 B2 G1 M1 CTL G2 M2 C1 C2 D1
OFF
ON
D2
Fan Filter
MA-DMX-405
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
4 - 5
Shelf Description
Product Description
Circuit pack slots and compatible circuit packs
The DMX high capacity shelf has 8 function unit slots, 2 Main slots, 2
Growth slots, and one Control slot.
Function units slots
The function unit slots are divided into four groups designated A, B, C, and D. Function unit slots A1, A2, B1, B2, C1, C2, D1, and D2 can be equipped, depending on the application, with the following circuit packs
• 28DS1
• 56DS1/E1
• 12DS3/EC1
• 48DS3/EC1
• 48DS3/EC1/TMUX
• TMUX
• OC-3
• OC-12 (LNW46 and LNW49)
• OC-48 (LNW31, LNW62, and LNW421 - LNW459 only)
• 10/100T
• 10/100-PL
• 1000BASE-LX
• 1000BASE-SX
• 1000BASE-X/ 100BASE-LX
• 100BASE-LX/ 10/100 BASE-TX
• SAN circuit pack with choice of FICON/ESCON/Fibre-channel interfaces using PTM optics (LNW73 and LNW73C)
When the shelf is equipped with non-VLF Mains (LNW59), Ethernet and SAN circuit packs are restricted to slot 1 of a function unit (for example, slot A1). If slot 1 of a function unit is equipped with an
Ethernet or SAN circuit pack, then slot 2 must be equipped with a 177D apparatus blank or an LNW98 detectable blank circuit pack.
When the shelf is equipped with the LNW59 VLF Main, Ethernet and
SAN packs can reside in Slots 1 and 2 of a function unit (see Chapter 5 for restrictions).
...........................................................................................................................................................................................................................................................
4 - 6
365-372-300
Issue 8.0, September 2006
Shelf Description
Product Description
Growth slots
Growth slots G1 and G2 can be equipped, depending on the application, with the following circuit packs:
• 48DS3/EC1TransMUX (LNW20)
• OC-3
• OC-12 (LNW46 and LNW49)
• OC-48 (LNW31, LNW62, and LNW421 - LNW459 only)
• 1000BASE-LX
• 1000BASE-SX
• 1000BASE-X/ 100BASE-LX
• 100BASE-LX/ 10/100 BASE-TX
• FC-DATA (FICON/FC/Fibre-Channel)
When the shelf is equipped with non-VLF Mains (LNW59), Ethernet and SAN circuit packs are restricted to slot G1. If slot G1 is equipped with an Ethernet or SAN circuit pack, then slot G2 must be equipped with a 177D apparatus blank or an LNW98 detectable blank circuit pack. The LNW66 and LNW71 can not be housed in the growth slots.
When the shelf is equipped with the LNW59 VLF Main, Ethernet and
SAN packs can reside in Slots 1 and G2 (See Chapter 5 for restrictions.
R7.0 also supports Link Aggregation on the LAN ports of the LNW70 when they are in switched mode. Link Aggregation can be used to provide protection on LNW70 Ethernet ports. For more information on
Link Aggregation, refer to Appendix A.
Also, the LNW74 can only be installed in G1 and only the optical ports are available for service.
The LNW20 (48 DS3/EC1TransMUX) will not function in Portless mode when the shelf is equipped with certain Main interface packs. It is also restricted to Portless mode only when installed in Growth Slots.
Therefore the LNW20 cannot ben used in the Growth Slots when certain Main packs are used (see
Main packs that allow portless LNW20 operation
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
4 - 7
Shelf Description
Product Description
Main slots
The main slots M1 and M2 can be equipped, depending on the application, with the following circuit packs:
• OC-12 OLIU circuit pack: LNW48, LNW50, and LNW54
• OC-48 OLIU circuit packs: LNW26B, LNW27, LNW28,
LNW29, LNW32, LNW76, LNW77, LNW121B-159B, or
LNW221-LNW259
• OC-192 OLIU circuit packs: LNW56, LNW57, LNW58, LNW59,
LNW60, LNW523, LNW527, LNW554, or LNW555
• Main Switch Circuit Pack: LNW80
The Stratum 3 timing generator and central TDM switch fabrics are embedded in the all of the MAIN circuit packs. If main slot M1 or M2 is not equipped with a circuit pack, the slot must be equipped with a
177E apparatus blank or an LNW97 detectable blank circuit pack.
There is no switch fabric on the blank circuit packs.
In R7.0, DMX introduces the LNW59 VLF Main. VLF Mains are designed to drastically increase the overall switch fabric capacity of
DMX. When DMX is equipped with VLF Mains, the switch fabrics of the low-speed, tributary packs are not used. Rather, all switching functions are performed on the VLF Main Fabric.
Control slot
The control slot CTL is reserved for the non-redundant System
Controller (SYSCTL) circuit pack. R6.0 (and all later releases) software requires the use of the LNW2 SYSCTL. The LNW1 is operational with R5.x software and all prior releases.
...........................................................................................................................................................................................................................................................
4 - 8
365-372-300
Issue 8.0, September 2006
Shelf Description
Product Description
Rear view (high-capacity shelf)
The figure below shows the various jacks and cable inputs on the DMX high-capacity shelf backplane.
Figure 4-2 DMX High Capacity Shelf Backplane Connectors
-48VB
-48RTNB
P15
J14
SYNC2
J11
MISC
J17
MODEM
J15
FAN
J9
SYNC1 P14
-48VA
-48RTNA
J22 C IN
J23 D IN
J26 C OUT
J27 D OUT
J20 A IN
J21 B IN
J24 A OUT
J25 B OUT
J19
INTEROP
J8
D OUT
J7
D IN
J6
C OUT
J5
C IN
J16
IAOLAN
EXP2
IN
CTL
OUT
J18
DLAN
J10
X.25
J12
ALM
EXP1
IN
OUT
CTL
J4
B IN
J13
ALM MULT
J3
B OUT
J2
A IN
J1
A OUT
NC-DMX-156
The shelf backplane provides the following connectors:
• Communications modem (J17 MODEM)
• Intraoffice LAN (J16 IAOLAN)
• External DS1 synchronization input and output (J9 SYNC1 and
J14 SYNC2)
• Fan shelf power/alarm (J15 FAN)
• -48 V DC power feeder A and B (P14 -48VA, -48RTNA and
P15 -48VB, -48RTNB)
• Miscellaneous (environmental) discrete telemetry (J11 MISC)
• TL1 interface (J10)
• Office alarm interface (J12 ALM)
• Office alarm multiple (J13 ALM MULT)
• J18 DLAN (Reserved for use in a future release)
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
4 - 9
Shelf Description
Product Description
• J19 INTEROP (Reserved for use in a future release)
• EXP1 IN, OUT, CTL (Reserved for use in a future release)
• EXP2 IN, OUT, CTL (Reserved for use in a future release)
• Eight DS1/DS3 and 10/100Base-T inputs (J2 A IN, J4 B IN,
J5 C IN, J7 D IN, J20 A IN, J21 B IN, J22 C IN, J23 D IN)
• Eight DS1/DS3 and 10/100Base-T outputs (J1 A OUT, J3 B OUT,
J6 C OUT, J8 D OUT, J24 A OUT, J25 B OUT, J26 C OUT,
J27 D OUT)
The -48 V DC power feeder interfaces (BAT A and BAT B) are located on the sides of the shelf.
...........................................................................................................................................................................................................................................................
4 - 1 0
365-372-300
Issue 8.0, September 2006
Product Description
Circuit Packs
............................................................................................................................................................................................................................................................
Available circuit packs
The table below contains a list of each circuit pack supported by the
DMX, indicates which slots they are able to be housed in, and in what release each circuit pack is available.
Table 4-2 Circuit Packs in DMX Shelf
Circuit Pack
System Controller
(SYSCTL)
Apparatus
Code
LNW1
Slot(s)
CTL
Release
1.0-5.x only
Comments
System Controller
(SYSCTL)
Main Switch Pack
LNW2
LNW80
CTL
M1, M2
6.0
4.0
Extended temp. certification for outside cabinet deployment (OSP
Hardened), supports R5.x software and earlier releases
New controller that must be used for for R6.0. Additional memory to support R6.0 and beyond. Extended temp. certification for outside cabinet deployment (OSP
Hardened)
High-speed, 96 STS-1 VT fabric, based on LNW 27, no optics on pack, OSP hardened.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
4 - 1 1
Circuit Packs
Circuit Pack
OC-192 OLIUs
Apparatus
Code
LNW59
Slot(s)
M1, M2
LNW58
LNW56
LNW60
M1, M2
M1, M2
M1, M2
LNW57 M1, M2
LNW523 M1, M2
LNW527 M1, M2
LNW554 M1, M2
LNW555 M1, M2
Product Description
Release Comments
7.0
2.1
2.1
5.1
4.0
4.0
4.0
4.0
3.1
2 port, High-speed, 1.3SR1/1.5IR2/
1.5LR2 via XFP PTMs, 20G optical main, 240G STS fabric, 30G VT termination capacity, and 40G VT fabric
High-speed, very short reach,
1310nm, 48 STS-1 VT fabric
High-speed, intermediate reach,
1550nm, 48 STS-1 VT fabric
High-speed, long reach, 1533.47 nm, 48 STS-1 VT fabric, with tone circuitry and on-board amplifier
High-speed, long reach, 1533.47 nm, 48 STS-1 VT fabric, with tone circuitry
High-speed, DWDM, 1550 nm range, 48 STS-1 VT fabric, tunable laser (four lambda range).
High-speed, DWDM, 1550 nm range, 48 STS-1 VT fabric, tunable laser (four lambda range).
High-speed, DWDM, 1550 nm range, 48 STS-1 VT fabric, tunable laser (four lambda range).
High-speed, long reach (80 km),
1550 nm range, 48 STS-1 VT fabric/ can also be used as a single channel (channel 55) DWDM pack.
...........................................................................................................................................................................................................................................................
4 - 1 2
365-372-300
Issue 8.0, September 2006
Circuit Packs
Circuit Pack
OC-48 OLIU
Product Description
Apparatus
Code
LNW26B
LNW27
LNW28
LNW29
LNW31
LNW32
LNW62
(4-port)
LNW76
LNW77
LNW121B-
LNW159B and
LNW221-
LNW259
LNW421-
LNW459
Slot(s) Release Comments
M1, M2
M1, M2
M1, M2
M1, M2
A-D, G1, G2 2.0
M1, M2
A-D, G1, G2
M1, M2
M1, M2
M1, M2
2.0
2.1
1.0
2.1
4.0
7.0
2.1
2.0
2.0 and 2.1
A-D, G1, G2 3.0
High-speed, long reach, 1310nm, 12
STS-1 VT fabric
High-speed, long reach, 1310nm, 48
STS-1 VT fabric
High-speed, long reach, 1310nm, 12
STS-1 VT fabric
, OSP Hardened
High-speed, long reach, 1550nm, 48
STS-1 VT fabric
Low-speed, intermediate reach,
1310nm, 12 STS-1 VT fabric
High-speed, long reach, 1310nm, 48
STS-1 VT fabric, OSP Hardened
4 port, Low-speed, 1.3LR1/1.5LR2 via PTMs, no switch fabric, requires use of LNW59 VLF Main, OSP
Hardened
High-speed, short reach, 1310nm,
48 STS-1 VT fabric
High-speed, intermediate reach,
1310nm, 12 STS-1 VT fabric
High-speed, 16 DWDM circuit packs support 32 different wavelengths in the 1550 nm range.
The 121B series supports 12 STS-1
VT fabric while the 221 series supports 48 STS-1 VT mapping.
Low-speed 16 DWDM circuit packs support 32 different wavelengths in the 1550 nm range, 12 STS-1 VT fabric.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
4 - 1 3
Circuit Packs
Product Description
Circuit Pack
OC-12 OLIU
(1 port)
OC-12 OLIU
(4 ports)
OC-12 OLIU
(2 ports)
OC-3 OLIU
(4 ports)
OC-3 OLIU
(4 ports)
OC-3 OLIU
(8 ports)
12DS3/EC1
48DS3/EC1
48DS3/EC1
48DS3/EC1/TMUX
(with portless operation)
Apparatus
Code
LNW48
LNW50
LNW54
LNW49
LNW46
LNW36
LNW37
LNW45
LNW16
LNW19
LNW19B
LNW20
Slot(s)
M1, M2
M1, M2
M1, M2
Release
3.1
3.1
5.1
A-D, G1, G2 4.0
A-D, G1, G2 1.1
A-D, G1, G2 1.1
A-D, G1, G2 4.0
A-D, G1, G2 5.0
A-D
A-D
A-D
A-G
(see comments)
1.0
3.1
5.0
7.0.1
Comments
High-speed, Intermediate reach.
1310 nm, OSP Hardened, 12 STS-1
VT fabric
High-speed, Long reach. 1310 nm,
OSP Hardened, 12 STS-1 VT fabric
High-speed, Long reach. 1550 nm,
OSP Hardened, 12 STS-1 VT fabric
Low-speed, 48 STS-1 VT fabric,
PTM optics, OSP hardened
Low-speed, long reach. 1310 nm,
12 STS-1 VT fabric, OSP Hardened
Low-speed, long reach 1310 nm,
12 STS-1 VT fabric, OSP Hardened
Low-speed, 12 STS-1 VT fabric,
PTM optics, OSP hardened, supports facility loopbacks, backwards compatible to R1.1
Low-speed, 48 STS-1 VT fabric,
PTM optics, OSP hardened, supports facility loopbacks
12 ports, OSP Hardened
48 ports, for use in DMX High
Capacity Shelf, OSP Hardened
48 ports, for use in DMX High
Capacity Shelf, OSP Hardened, supports DS3 Loopbacks
48 ports, OSP Hardened, DS3, EC1, and TMUX functionality on a portby-port basis. LNW20 is supported in G1/2 for portless mode only with certain Mains. When Mains that don’t support portless are used,
LNW20 can only be installed in A-
D
...........................................................................................................................................................................................................................................................
4 - 1 4
365-372-300
Issue 8.0, September 2006
Circuit Packs
Product Description
Circuit Pack
DS1/DS3
TransMUX
28DS1
28DS1PM
56DS1/E1
Electrical
Continuity Test
Tool
In-service
Electrical
Continuity Test
Tool
1000BASE-SX/LX/
ZX (4 ports)
Private Line
1000BASE-TX/SX/
LX/ZX (8 ports)
Private Line
Apparatus
Code
LNW18
Slot(s)
A-D
LNW6
LNW7
LNW8
LNW94
LNW93
LNW63
LNW64
A-D
A-D
A-D
A-D
A-D
Release Comments
3.0
1.0
1.0
3.1
3.1
4.0
A-G
(See Note 1)
6.0
A-G
(See Note 1)
7.0
12 ports, receives/transmits channelized DS3, OSP Hardened
28 ports, OSP Hardened, not supported with VLF Mains
28 ports, OSP Hardened, not supported with VLF Mains
56 ports, for use in DMX High
Capacity Shelf, OSP Hardened, E1 service is provisionable on a per pack basis, E1 became available in
R4.0
For use in DMX to test the integrity of cables connected to the DS1,
DS3, and Ethernet interfaces on the
DMX shelf
For use in DMX to test the integrity of cables that will be connected to a high-capacity DS1, DS3, or
Ethernet circuit pack while a lower capacity pack is in-service in the other slot of the function group.
1000BASE-SX/LX/ZX Ethernet interface via optical PTMs, can be used is slot 1 and/or 2 in a VLF equipped DMX and either slot 1 or
2 in a non-VLF equipped DMX,
GbE private lines, includes no switch fabric, OSP hardened
1000BASE-TX/SX/LX/ZX
Ethernet interface via PTMs, can be used is slot 1 and/or 2 in a VLF equipped DMX and in slot 1 in a non-VLF equipped DMX, GbE private lines, includes no switch fabric, OSP hardened
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
4 - 1 5
Circuit Packs
Product Description
Circuit Pack
10/100T
(24 ports)
10/100 PL (24 ports)
Private Line
Apparatus
Code
LNW66
LNW71
Slot(s)
A-D
(See Note 2)
A-D
(See Note 2)
Release
1.1
3.1
1GbE SX
(2 ports)
1GbE LX
(2 ports)
Enhanced Ethernet
Switch Pack
(100/1000 BASE-T or 1000BASE-LX/
SX
—
4 ports,
10/100 LX
—
4 ports
FC-DATA
(SAN Interface)
FC-DATA w/ compression
(SAN Interface)
LNW67
LNW68
LNW70
LNW73
LNW73C
A-G
(See Note 1)
1.1
A-G
(See Note 1)
1.1
A-G
(See Note 1)
5.1
A-G
(See Note 1)
5.1
A-G
(See Note 1)
7.0
Comments
100BASE-TX Ethernet interface
100BASE-TX PL Ethernet interface, supports Ethernet Private
Lines
1000BASE-SX Ethernet interface, may occupy slot 1 or 2 of a function group or a growth slot, requires multi-mode cable
1000BASE-LX Ethernet interface, may occupy slot 1 or 2 of a function group or a growth slot, requires single-mode cable
Hybrid 100/1000 BASE-TX or
1000BASE-X (ports 1-4), and 100
BASE-LX (ports 5-8) Ethernet interface, may occupy slot 1 or 2 of a function group or a growth slot, uses PTMs, supports enhanced
Ethernet QoS
4 ports, PTM optics supporting either FICON/Fibre-Channel or
ESCON, can be installed in slot 1 or
2 of a function group or a growth slot with VLF mains, slot 1 only with non-VLF
4 ports, PTM optics supporting either FICON/Fibre-Channel or
ESCON, also supports compression of SAN traffic, can be installed in slot 1 or 2 of a function group or a growth slot with VLF mains, slot 1 only with non-VLF
...........................................................................................................................................................................................................................................................
4 - 1 6
365-372-300
Issue 8.0, September 2006
Circuit Packs
Product Description
Circuit Pack
100BASE-LX
(8 ports)
10/100BASE-TX
(16 ports)
Private Line
Apparatus Blank
Apparatus Blank
Detectable
Apparatus Blank
Detectable
Apparatus Blank
Apparatus
Code
LNW74
Slot(s)
A-G
(See Note 1)
Release
5.0
RPR 1GbE X
100/1000BASE-X
(2 ports),
100BASE-LX
(4 ports)
LNW78
177D
177E
LNW97
LNW98
A-G
(See Note 1)
6.0
A-D, G1, G2 1.0
M2
M2
2.0
3.1
A-D, G1, G2 3.1
Comments
Hybrid 100BASE-LX and 10/100
BASE-TX Ethernet interface, OSP hardened, may only occupy slot 1 of a function group or a growth slot, uses PTM optics for LX interfaces, supports private lines, when in G1 slot, only the optical ports (17-24) of the LNW74 function
Hybrid 100/1000BASE-X and 100
BASE-LX Ethernet interface, may only occupy slot 1 of a function group or a growth slot if non-VLF mains are used, slot 1 and 2 are available with VLF mains, uses
PTM optics, supports RPR protection and enhanced Ethernet
QoS, adds support for Ethernet over
SONET in R7.0
Filler plates to be used in unpopulated slots of the DMX shelf
Filler plates to be used in unpopulated slots of the DMX shelf
Filler plates to be used in unpopulated M2 slot of the
DMX shelf. The PC-CIT will show a blank plate when slot is equipped with this pack.
Filler plates to be used in unpopulated Function Unit or
Growth Slot of the
DMX
shelf. The
PC-CIT will show a blank plate when slot is equipped with this pack.
Notes
1. In order to support Ethernet and SAN packs in both Slot 1 and 2 of a
Function Group or Growth Slot, DMX must be equipped with VLF
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
4 - 1 7
Circuit Packs
Product Description
Mains (LNW59) and R7.0 software.
2. DMX does not allow installation of two packs with electrical interfaces in adjacent slots within the same Function Unit or Growth
Group (other then an equipment-protected pair). Therefore, in systems equipped with LNW59 VLF mains, LNW66 and LNW71 packs can reside in either Slot 1 or Slot 2 of a group, but not both at the same time.
Telcordia will only support electrical packs in Slot 1 of a group.
However, another optical (Ethernet or SONET) pack may be installed in the other slot. In non-VLF equipped shelves, LNW66 and LNW71 can only occupy Slot 1 of a particular group.
3. When populating the MAIN slots in the DMX shelf, it is imperative that both MAIN 1 and MAIN 2 contain circuit packs with identical VT switch fabric size. The DMX OC-48 circuit packs, for example, contain fabrics ranging from 6 to 48 STS-1 capacity. It is therefore very important that you look carefully at the switch fabric sizes of your high-speed circuit packs while planning your order.
This information can be found in the Comments column of the table above, or in the text associated with the various circuit packs detailed in the following section.
...........................................................................................................................................................................................................................................................
4 - 1 8
365-372-300
Issue 8.0, September 2006
Product Description
Circuit Pack Descriptions
............................................................................................................................................................................................................................................................
Overview
This section briefly describes DMX circuit packs.
System Controller (LNW1)
The LNW1 is operational with Release 5.x software and all prior releases. It cannot be used with R6.0 and later releases
The SYSCTL provides communication with other circuit packs on the
DMX shelf. The SYSCTL supports all DMX operations interfaces, including IAO LAN (OSI or TCP/IP), TL1/X.25, PC-CIT, office alarms, and miscellaneous discretes. The SYSCTL also supports DCC terminations for each optical line interface.
The SYSCTL faceplate has push-button switches, alarm/status LEDs, and a 7-segment numeric display to facilitate local operations. The
SYSCTL provides redundancy by duplicating all cross-connect information on the OLIU circuit packs. Transmission is not affected if the SYSCTL fails.
The SYSCTL circuit pack provides a microprocessor, nonvolatile memory to store the generic program software and provisioning database, and additional memory for system operation. The SYSCTL circuit pack also has interfaces across the backplane to monitor and control every circuit pack in the shelf.
The SYSCTL supports PC-CIT front access to the DMX via the IAO
LAN and a serial RS-232 port located on the back of the DMX shelf.
System Controller (LNW2)
The LNW2 functions in the same capacity and with the same capabilities as LNW1, except that it contains a memory upgrade to support the enhanced feature sets of R6.0 and upcoming releases and it does not support X.25. The LNW2 must be used with R6.0 and later releases.
LNW2 also contains two removable Non-volatile Memory (NVM) cards that are separately orderable from the LNW2 card itself (although the SYSCTL does come equipped with two NVM cards). A DMX shelf running R6.0 software will only function properly when it is equipped with a LNW2 card that contains two fully functioning NVM cards. The
NVM cards are removable/replaceable.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
4 - 1 9
Circuit Pack Descriptions
Product Description
Main Switch Pack
(LNW80)
The LNW80 high-speed circuit pack is designed to save cost in CO hub applications where there is no need to transmit traffic over networkside interfaces. LNW80 is best used in a DCS type of application. It can cross-connect signals amongst multiple low-speed tributary interfaces and perform VT mapping into OC-3/12/48 tributaries. It can crossconnect signals at the VT1.5, STS-1, STS-3(c), STS-12(c), and STS-
48(c) level. The Stratum 3 timing generator and central TDM switch fabrics are embedded in the LNW80.
The LNW80 circuit pack design is based on the design/capabilities of the LNW27 pack, minus the optical interfaces.
The LNW80 circuit pack supports VT mapping in 96 STS-1s.
The LNW80 may occupy Main slots 1 and 2 and contains NO interfaces on the faceplate of the pack. Due to the increased switch fabric size and the absence of any optics on the pack’s faceplate, the
LNW80 is not upgradeable to a high-speed optical pack.
28DS1 (LNW6) and
28DS1PM (LNW7)
The LNW6 and LNW7 are not supported when DMX is equipped with
VLF Main (LNW59) packs. LNW6/7 contain 28 DS1 ports that can be cross-connected to VT1.5 timeslots when the system is operating with a
UPSR, 1+1, or BLSR Main interface. Hairpin cross-connections to OCn and other electrical interfaces are also supported. Both packs are 1x1 protected, and non-revertive protection switching is supported. Line build-outs and DS1 signal encoding are software provisionable. Both circuit packs terminate up to 28 bidirectional DS1 electrical signals and support the transport of DS1 signals coded in either alternate mark inversion (AMI) or bipolar 8-zero substitution (B8ZS) modes. The signals received from the DSX-1 are mapped into SONET VT1.5 signals and then routed to the high-speed OLIU circuit pack.
Both circuit packs can occupy Function Unit groups A, B, C, and D.
All electric interface circuit packs are 1x1 hardware protected. So, although both slots in each function group can house a LNW6 or
LNW7 circuit pack, one slot in each function group populated by
LNW6 or LNW7 circuit packs is always used for hardware protection.
Thus the DMX shelf supports up to 112 working ports when four
Function Unit groups are equipped with the LNW6 or LNW7 circuit pack.
In addition to maintenance and provisioning functions, the 28DS1PM circuit pack provides performance monitoring capabilities.
Whenever upgrading LNW6 to LNW7 circuit packs, it is necessary to first install an LNW8 circuit pack to ensure that the upgrade is completed without loss of service.
...........................................................................................................................................................................................................................................................
4 - 2 0
365-372-300
Issue 8.0, September 2006
Circuit Pack Descriptions
Product Description
56DS1/E1 (LNW8)
These circuit packs can be used only in the high capacity shelf and contain 56 DS1/E1 ports that can be cross-connected to VT or STS-1 timeslots in DS1 mode and STS3(c) timeslots in E1 mode. 56DS1/E1 packs are 1x1 protected by default, and non-revertive protection switching is supported. LNW8 can be provisioned for 0x1 protection, allowing the pack to go unprotected. Yet, DMX does not allow electrical TDM packs (and other packs that require rear access) to be paired with any other working packs in the same Function group or
Growth slot. For a detailed description of circuit pack slot equipage guidelines, refer to Chapter 5.
Line build-outs and DS1 signal encoding are software provisionable.
These packs terminate up to 56 bidirectional DS1 electrical signals and support the transport of DS1 signals coded in either alternate mark inversion (AMI) or bipolar 8-zero substitution (B8ZS) modes. The signals received from the DSX-1 are mapped into SONET VT1.5 signals and then routed to the high-speed OLIU circuit pack. DS1 signals can be connected directly to high-speed BLSRs at the VT1 rate.
The E1 ports have 120 Ohm terminations, and are HDB3-encoded. The mapping is E1 <-> VC-12 <-> TU-12 <-TUG2 <-> TUG3 <->VC-4
(treated as an STS3c). When the LNW8 is provisioned for E1 interfaces the output of the card will always be an STS-3c regardless of the amount of traffic it is actually handling.
56DS1/E1 circuit packs can occupy Function Unit groups A, B, C, and
D. Electric interface circuit packs are 1x1 hardware protected. So, although both slots in each function group can house a LNW8 circuit packs, one slot in each function group populated by LNW8 circuit packs is always used for hardware protection. Thus the DMX shelf supports up to 224 working ports when four Function Unit groups are equipped with the LNW8 circuit pack.
In addition to maintenance and provisioning functions, the 56DS1/E1 circuit pack provides performance monitoring capabilities.
12DS3/EC1 (LNW16)
The 12DS3/EC1 (LNW16) circuit pack contains 12 ports and supports non-revertive protection switching. The 12DS3/EC1 circuit pack provides bidirectional transport of 12 DS3 or EC-1 signals and maps the DS3s into STS-1 signals, and supports transport of DS3 signals coded in bipolar 3-zero substitution (B3ZS). DS3 or EC-1 service is provisionable on a per-port basis within each pack.
The LNW16 may occupy Function Unit groups A, B, C, and D.
Electric interface circuit packs are 1x1 hardware protected. So, although both slots in each function group can house a LNW16 circuit
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
4 - 2 1
Circuit Pack Descriptions
Product Description
pack, one slot in each function group populated by LNW16 circuit pack is always used for hardware protection. Thus the DMX shelf supports up to 48 working ports when four Function Unit groups are equipped with the LNW16 circuit packs.
Trans/MUX circuit pack
(LNW18)
DMX supports a 12-port Trans/MUX card that can collect various DS1 signals from around a ring and combine them into a channelized DS3 signal. LNW18 is environmentally hardened for outside plant (OSP) deployments.
The LNW18 may occupy Function Unit groups A, B, C, and D.
Electric interface circuit packs are 1x1 hardware protected. So, although both slots in each function group can house a LNW18 circuit pack, one slot in each function group populated by LNW18 circuit pack is always used for hardware protection. Thus the DMX shelf supports up to 48 working ports when four Function Unit groups are equipped with the LNW18 circuit packs.
The Trans/MUX circuit pack functions in the following manner:
Transmit Functions
• Receives a B3ZS-encoded DS3 signal from a DSX-3
• Recovers DS3 clock and NRZ data
• Calculates parity errors on the DS3 input
• Demultiplexes the M13 or C-bit formatted DS3 signal into 28
DS1s
• Maps the 28 DS1s into VT1.5s and then into an STS-1
• Inserts STS-1 path overhead
• Provides the STS-1 signal to the OLIU circuit packs
Receive Functions
• Interprets the STS-1 pointer values
• Terminates the STS-1 path
• Disinterleaves the STS-1 signal into 28 VT1.5s and interprets VT pointer values
• Converts the VT1.5 signals to 28 DS1 signals
• Multiplexes the 28 DS1 signals to an M13 or C-bit formatted DS3 signal
• B3ZS encodes the outgoing DS3 signal
• Pre-equalizes the DS3 signal (with LBO) and transmits it to a
DSX-3
...........................................................................................................................................................................................................................................................
4 - 2 2
365-372-300
Issue 8.0, September 2006
Circuit Pack Descriptions
Product Description
48DS1/E1/TransMUX
(LNW20
—
R7.0.1)
The LNW20 provides 48 ports supporting DS3, EC1, and TMUX functionality on a port-by-port basis. Each port can be individually provisioned as DS3 or EC1 (unchannelized), or as TransMUX
(channelized DS3s). With the LNW20, one high-density pack can be used for all DS3, EC1, and/or TransMUX applications.
The LNW20 can also function in portless mode. Portless mode does not utilize any of the electrical ports on the pack. When operating in portless mode, LNW20 pulls DS1s from channelized DS3 signals that enter DMX on a SONET STS-1 interface (on another pack) and converts them to VT mapped STS-1s. This VT-mapped STS-1 is crossconnected at the VT level in the Main packs (at least one side of the cross-connect is OCn/EC1) to any interface that supports the signal structure today (DS1, channelized DS3, EC1, optical). Portless mode can be provisioned on a per-port basis. When certain Mains are used, only odd numbered ports can be configured as portless and the corresponding even-numbered port will be unavailable for service.
LNW20 can be 1x1 protected or function in 0x1 unprotected mode. It supports hairpins to other packs in the shelf, and between ports on the same pack. LNW20 can occupy slots A1/A2 through G1/G2 when the
LNW59 VLF Main is used. LNW20 only functions in portless mode in
G1/G2. Certain Main packs do not support portless mode (see table below). Therefore, when these packs are used, LNW20 cannot be used in G1/G2.
Table 4-3 Main packs that allow portless LNW20 operation
Rate
OC-48
Circuit packs
LNW27
LNW29
LNW32
LNW76
LNW221-259
OC-192 LNW56
LNW57
LNW58
LNW59
LNW60
LNW521-559
Switch pack (headless) LNW80
DMX does not allow 2 electrical TDM packs of different types (or any packs that require rear access) to occupy adjacent slots in the same
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
4 - 2 3
Circuit Pack Descriptions
Product Description
Function Group. So, although 0x1 functionality allows LNW20 to function unprotected, overall capacity is not increased. A total of 192 ports are available when all slots are equipped with LNW20 circuit packs (a maximum of 240 ports are available when the LNW20 is functioning in portless mode and the shelf is equipped with VLF
Mains). This is because LNW20 must function in portless mode when installed in the Growth Slots. Though the LNW20 supports 0x1 protection, companion slots (ex. A1 and A2) can only be equipped with
LNW20 packs (no circuit pack/interface mixing in the same Function
Group) providing 1+1 protection.
OC-3 OLIU (LNW36)
The quad OC-3 OLIU low-speed circuit pack is a four-port, long-reach,
1310 nm optical line interface unit supporting VT1.5, STS-1 and STS-
3c path switching. LNW36 supports VT mapping in 12 STS-1s. The
LNW36 can interface with other OC-3 rings in the network and can also be used as an interface for OC-3 linear optical extensions, as well as single- and dual- homed ring extensions. Fiber access is provided via four pairs of LC-type connectors on the LNW36 faceplate.
The LNW36 can occupy any Function Unit group on the DMX shelf
(including Growth slots), and up to 40 ports are addressable when all
Function Unit groups are equipped with the LNW36 circuit pack.
The LNW36 is being DA’d and will no longer be available as of 12/31/
07.
OC-3 OLIU (LNW37)
The quad OC-3 OLIU low-speed circuit pack is a four-port, PTMbased optical line interface unit supporting VT1.5, STS-1 and STS-3c path switching. The LNW37 can interface with other OC-3 rings in the network and can also be used as an interface for OC-3 linear optical extensions, as well as single- and dual- homed ring extensions. LNW37 supports VT mapping in 12 STS-1s. The LNW37 also supports facility loopbacks for testing purposes. The LNW37 is OSP hardened.
The LNW37 features Pluggable Transmission Module (PTM) optics, also known as SFP optics. PTM optics are “pluggable” in the sense that they can be plugged into a circuit pack as they become necessary. This allows customers to grow their network incrementally, only realizing the full cost for optics as the need to provision service on (and thus receive revenue from) them becomes necessary. LNW37 packs are purchased and shipped with no sockets populated with functioning optics. The ports remain empty until the customer decides to place optics in them.
...........................................................................................................................................................................................................................................................
4 - 2 4
365-372-300
Issue 8.0, September 2006
Circuit Pack Descriptions
Product Description
OC-3 OLIU (LNW45)
The LNW37 can occupy any Function Unit group on the DMX shelf
(including Growth slots), and up to 40 ports are addressable when all
Function Unit groups are equipped with the LNW37 circuit pack. The
LNW37 is also backward compatible to R1.1.
The OC-3 OLIU low-speed circuit pack is an 8-port, PTM-based optical line interface unit supporting VT1.5, STS-1 and STS-3(c) path switching. The LNW45 can interface with other OC-3 rings in the network and can also be used as an interface for OC-3 linear optical extensions, as well as single- and dual- homed ring extensions. LNW45 supports VT mapping in 48 STS-1s. The LNW45 also supports facility loopbacks for testing purposes. The LNW45 is OSP hardened.
The LNW45 features Pluggable Transmission Module (PTM) optics, also known as SFP optics. PTM optics are “pluggable” in the sense that they can be plugged into a circuit pack as they become necessary. This allows customers to grow their network incrementally, only realizing the full cost for optics as the need to provision service on (and thus receive revenue from) them becomes necessary. LNW45 packs are purchased and shipped with no sockets populated with functioning optics. The ports remain empty until the customer decides to place optics in them.
The LNW45 can occupy any Function Unit group on the DMX shelf
(including Growth slots), and up to 80 ports are addressable when all
Function Unit groups are equipped with the LNW45 circuit pack.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
4 - 2 5
Circuit Pack Descriptions
Product Description
OC-12 OLIU (LNW46)
The dual OC-12 OLIU (LNW46) low-speed circuit pack is a two-port, long-reach, 1310 nm optical line interface unit supporting VT1.5, STS-
1, STS-3(c), and STS-12(c) path switching. LNW46 supports VT mapping in 12 STS-1s. The LNW46 provides an OC-12 interface to other OC-12 rings, linear optical extensions, and single- and dualhomed ring extensions. Fiber access is provided via two pairs of LCtype connectors on the LNW46 faceplate.
The LNW46 can occupy any Function Unit group on the DMX shelf
(including Growth slots), and up to 20 ports are addressable when all
Function Unit groups are equipped with the LNW46 circuit pack.
The LNW46 is being DA’d and will no longer be available as of 12/31/
07.
OC-12 OLIU (LNW48)
The OC-12 OLIU (LNW48) high-speed circuit pack is an intermediate reach 1310 nm circuit pack. The LNW48 supports OC-12 add/drop,
UPSR configurations, single- and dual-homing, non-revertive linear and bidirectional 1+1 protection switching, and VT1.5, STS-1, STS-
3(c), and STS-12(c) signal transport. The LNW48 OLIU can crossconnect VTs in 12 of 12 STS-1s. The Stratum 3 timing generator and central TDM switch fabrics are embedded in the OC-12 OLIU.
The LNW48 may occupy Main slots 1 and 2. Fiber access is provided via a pair of LC-type connectors on the LNW48 faceplate.
OC-12 OLIU (LNW49)
The quad OC-12 OLIU (LNW49) low-speed circuit pack is a four-port,
PTM-based optical line interface unit supporting VT1.5, STS-1, STS-
3(c), and STS-12(c) path switching. LNW49 supports VT mapping in
48 STS-1s. The LNW49 provides an OC-12 interface to other OC-12 rings, linear optical extensions, and single- and dual-homed ring extensions. LNW49 supports VT mapping in 48 STS-1s.
The LNW49 features Pluggable Transmission Module (PTM) optics.
PTM optics are “pluggable” in the sense that they can be plugged into a circuit pack as they become necessary. This allows customers to grow their network incrementally, only realizing the full cost for optics as the need to provision service on (and thus receive revenue from) them becomes necessary. LNW49 packs are purchased and shipped with no ports populated with functioning optics. The ports remain empty until the customer decides to place optics in them.
The LNW49 can occupy any Function Unit group on the DMX shelf
(including Growth slots), and up to 40 ports are addressable when all
Function Unit groups are equipped with the LNW49 circuit pack. The
LNW49 is approved for OSP deployments.
...........................................................................................................................................................................................................................................................
4 - 2 6
365-372-300
Issue 8.0, September 2006
Circuit Pack Descriptions
Product Description
OC-12 OLIU (LNW50)
The OC-12 OLIU (LNW50) high-speed circuit pack is a long reach
1310 nm circuit pack. The LNW50 supports OC-12 add/drop, UPSR configurations, single- and dual-homing, non-revertive 1+1 linear protection switching, and VT1.5, STS-1, STS-3(c), and STS-12(c) signal transport. The LNW50 OLIU can cross-connect VTs in 12 of 12
STS-1s. The Stratum 3 timing generator and central TDM switch fabrics are embedded in the OC-12 OLIU.
The LNW50 may occupy Main slots 1 and 2. Fiber access is provided via a pair of LC-type connectors on the LNW50 faceplate.
OC-12 OLIU (LNW54)
The OC-12 OLIU (LNW54) high-speed circuit pack is a long reach
1550 nm circuit pack. The LNW54 supports OC-12 add/drop, UPSR configurations, single- and dual-homing, non-revertive 1+1 linear protection switching, and VT1.5, STS-1, STS-3(c), and STS-12(c) signal transport. The LNW54 OLIU can cross-connect VTs in 12 of 12
STS-1s. The Stratum 3 timing generator and central TDM switch fabrics are embedded in the OC-12 OLIU.
The LNW54 may occupy Main slots 1 and 2. Fiber access is provided via a pair of LC-type connectors on the LNW54 faceplate.
OC-48 OLIU (LNW26B)
The LNW26B high-speed circuit pack is a long reach OC-48, 1310 nm optical line interface unit. The LNW26B supports OC-48 add/drop,
BLSR and UPSR configurations, single- and dual-homing, nonrevertive linear and bidirectional 1+1 protection switching, and VT1.5,
STS-1, STS-3(c), STS-12(c), and STS-48) signal transport. The
LNW26B pack can cross-connect VTs in 12 of 48 STS-1s of the OC-48 signal. The Stratum 3 timing generator and central TDM switch fabrics are embedded in the OC-48 OLIU.
The LNW26B may occupy Main slots 1 and 2. Fiber access is provided via a pair of LC-type connectors on the LNW26B faceplate.
OC-48 OLIU (LNW27)
The LNW27 high-speed circuit pack is a long reach OC-48, 1310 nm optical line interface unit. The LNW27 supports OC-48 add/drop,
BLSR and UPSR configurations, single- and dual-homing, nonrevertive linear and bidirectional 1+1 protection switching, and VT1.5,
STS-1, STS-3(c), STS-12(c), and STS-48(c) signal transport. The
Stratum 3 timing generator and central TDM switch fabrics are embedded in the OC-48 OLIU.
The LNW27 circuit pack can cross-connect VTs in all 48 STS-1s of the
OC-48 signal.
365-372-300
Issue 8.0, September 2006
The LNW27 may occupy Main slots 1 and 2. Fiber access is provided via a pair of LC-type connectors on the LNW27 faceplate.
............................................................................................................................................................................................................................................................
4 - 2 7
Circuit Pack Descriptions
Product Description
OC-48 OLIU (LNW28)
The LNW28 will no longer be available as of 5/17/06.
The LNW28 has the same capabilities as the LNW26B circuit pack. It is, however, designed specifically for outside cabinet deployment and has been certified to withstand extreme temperatures.
The OC-48 OLIU (LNW28) high-speed circuit pack is a long reach
1310 nm optical line interface unit. The LNW28 supports OC-48 add/ drop, BLSR and UPSR configurations, single- and dual-homing, nonrevertive linear and bidirectional 1+1 protection switching, and VT1.5,
STS-1, STS-3(c), STS-12(c), and STS-48(c) signal transport. The
LNW28 can cross-connect 12 of 48 selected STS-1s. The Stratum 3 timing generator and central TDM switch fabrics are embedded in the
OC-48 OLIU.
The LNW28 may occupy Main slots 1 and 2. Fiber access is provided via a pair of LC-type connectors on the LNW28 faceplate.
OC-48 OLIU (LNW29)
The LNW29 high-speed circuit pack is a long reach OC-48, 1550 nm optical line interface unit. The LNW29 supports OC-48 add/drop,
BLSR, UPSR, and 1+1 configurations, single- and dual-homing, nonrevertive linear and bidirectional 1+1 protection switching, and VT1.5,
STS-1, STS-3(c), STS-12(c), and STS-48(c) signal transport. The
Stratum 3 timing generator and central TDM switch fabrics are embedded in the OC-48 OLIU.
The LNW29, like the LNW27 circuit pack, can cross-connect VTs in all 48 STS-1s of the OC-48 signal.
The LNW29 may occupy Main slots 1 and 2. Fiber access is provided via a pair of LC-type connectors on the LNW29 faceplate.
OC-48 OLIU (LNW31)
The OC-48 OLIU low-speed circuit pack is a single port
(bidirectional), intermediate reach, 1310 nm optical line interface unit.
The LNW31 supports OC-48 add/drop, BLSR, UPSR, and 1+1 configurations, single- and dual-homing, non-revertive linear and bidirectional 1+1 protection switching, and VT1.5, STS-1, STS-3(c),
STS-12(c), and STS-48(c) signal transport. The LNW31 circuit pack can route VTs in 12 STS-1s of the OC-48 signal to the MAIN circuit packs for VT grooming. The central TDM switch/grooming fabrics are embedded in the OC-48 MAIN OLIU.
The LNW31 may occupy any Function Unit group on the DMX shelf
(including Growth slots), and up to 10 ports are addressable when all
Function Unit groups are equipped with the LNW31 circuit pack. Fiber access is provided via a pair of LC-type connectors on the LNW31 faceplate.
...........................................................................................................................................................................................................................................................
4 - 2 8
365-372-300
Issue 8.0, September 2006
Circuit Pack Descriptions
OC-48 OLIU (LNW32)
Product Description
OC-48 OLIU (LNW62
—
R7.0)
The LNW32 high-speed circuit pack is a long reach OC-48, 1310 nm optical line interface unit. LNW32 is OSP hardened for outside plant applications. The LNW32 supports OC-48 add/drop, BLSR and UPSR configurations, single- and dual-homing, non-revertive linear and bidirectional 1+1 protection switching, and VT1.5, STS-1, STS-3(c),
STS-12(c), and STS-48(c) signal transport. The Stratum 3 timing generator and central TDM switch fabrics are embedded in the OC-48
OLIU.
The LNW32 circuit pack can cross-connect VTs in all 48 STS-1s of the
OC-48 signal.
The LNW32 may occupy Main slots 1 and 2. Fiber access is provided via a pair of LC-type connectors on the LNW32 faceplate.
LNW62 is a 4 port OC-48 circuit pack supporting add/drop, UPSR, and
BLSR configurations, single- and dual-homing, non-revertive or revertive linear 1+1 protection switching, and 0x1 operation. A maximum of 16 BLSRs (between low-speed and high-speed slots) are supported per shelf when the LNW62 is equipped in all tributary slots and LNW59 VLF Mains are used in the Main slots.
The LNW62 provides 4 PTM (also known as SFP) ports capable of supporting 1.3LR1 and 1.5LR2 PTMs.
As an R7.0 circuit pack, the LNW62 does not have an on-board switch fabric and therefore can only be used with the LNW59 packs in the
Main slots. All switching functions are performed on the VLF Main packs (LNW59).
LNW62 supports VT1.5, STS-1, STS-3c, STS-12c, and STS-48c signal transport. The LNW62 boasts a 10G backplane interface capacity and may occupy both Function and Growth slots, providing a total port density of 20 OC-48 ports per shelf if every Function and Growth slot is equipped with an LNW62.
OC-48 OLIU (LNW76)
The LNW76 high-speed circuit pack is a short reach, 1310 nm optical line interface unit. It is designed for intra-office transmission. The
LNW76 supports OC-48 add/drop, BLSR, UPSR, and 1+1 configurations, single- and dual-homing, non-revertive linear and bidirectional 1+1 protection switching, and VT1.5, STS-1, STS-3(c),
STS-12(c), and STS-48(c) signal transport. The Stratum 3 timing generator and central TDM switch fabrics are embedded in the OC-48
OLIU.
The LNW76 circuit pack can cross-connect VTs in all 48 STS-1s of the
OC-48 signal.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
4 - 2 9
Circuit Pack Descriptions
Product Description
The LNW76 may occupy Main slots 1 and 2. Fiber access is provided via a pair of LC-type connectors on the LNW76 faceplate.
OC-48 OLIU (LNW77)
The LNW77 circuit pack is a intermediate reach (20km), high-speed
1310 nm optical line interface unit. The LNW77 supports OC-48 add/ drop, BLSR and UPSR configurations, single- and dual-homing, nonrevertive linear and bidirectional 1+1 protection switching, and VT1.5,
STS-1, STS-3(c), STS-12(c), and STS-48(c) signal transport. The
Stratum 3 timing generator and central TDM switch fabrics are embedded in the OC-48 OLIU.
The LNW77 pack can cross-connect VTs in 12 of 48 STS-1s of the
OC-48 signal.
The LNW77 may occupy Main slots 1 and 2. Fiber access is provided via a pair of LC-type connectors on the LNW77 faceplate.
OC-48 High-speed (network interface) DWDM OLIUs
The DMX OC-48 DWDM OLIUs are optical port units designed for use with passive MUX/DMUX and optical add/drop shelves. This
DWDM feature supports 32 different wavelengths. Each port unit supports two wavelengths via a special hardware configuration. These units are compatible with the SONET and SDH standards.
The optical port units are designed to be used with the Lucent Passive
Optics Units (POUs). By using the DWDM port units and the POUs, you are able to increase fiber capacity by a factor of 16 or 32.
OC-48 DWDM OLIUs support add/drop, BLSR and UPSR configurations, single- and dual-homing, non-revertive linear and bidirectional 1+1 protection switching, and VT1.5, STS-1, STS-3(c),
STS-12(c), and STS-48(c) signal transport. The Stratum 3 timing generator and central TDM switch fabrics are embedded in the OC-48
OLIU.
One set of OC-48 DWDM OLIUs can cross-connect VTs in any 12 of
48 selected STS-1s (LNW121B-159B). Another set of OC-48 DWDM
OLIUs can cross-connect VTs in all 48 STS-1s of the OC-48 signal
(LNW221-259).
The OC-48 DWDM OLIUs may occupy Main slots 1 and 2. Fiber access is provided via a pair of LC-type connectors on the OC-48
DWDM OLIU faceplate.
The LNW121B, 123B, 131B, 135B, 137B, 143B, 145B, 147B, 149B,
157B, and 159B packs are no longer available. All other 100 series packs will still be available. The LNW221, 243, and 257 packs are no longer available. All other 200 series packs will still be available.
...........................................................................................................................................................................................................................................................
4 - 3 0
365-372-300
Issue 8.0, September 2006
Circuit Pack Descriptions
Product Description
OC-48 Low-speed (tributary interface) DWDM OLIUs
The low-speed OC-48 DWDM OLIUs (LNW421-459) are similar to those mentioned above, except that they are tributary interface circuit packs that any Function Unit group on the DMX shelf (including
Growth slots), and up to 10 ports are addressable when all Function
Unit groups are equipped with the low-speed DWDM circuit packs.
These packs can cross-connect VTs in any 12 of 48 selected STS-1s.
The LNW421, 423, 431, 433, 435, 437, 443, 445,457 packs are no longer available. All other 400 series packs will still be available.
OC-192 OLIU (LNW56)
The OC-192 OLIU (LNW56) circuit pack is an intermediate reach
1550 nm optical line interface unit. The LNW56 supports OC-192 add/ drop, UPSR, and BLSR configurations, single- and dual-homing, nonrevertive linear and bidirectional 1+1 protection switching, and VT1.5,
STS-1, STS-3(c), STS-12(c), and STS-48(c) signal transport. The
LNW56 circuit pack can cross-connect VTs in any 48 of 192 STS-1s in the OC-192 signal. The Stratum 3 timing generator and central TDM switch fabrics are embedded in the OC-192 OLIU.
The LNW56 may occupy Main slots 1 and 2. Fiber access is provided via a pair of LC-type connectors on the LNW56 faceplate.
OC-192 OLIU (LNW57)
The OC-192 OLIU (LNW57) circuit pack is a long reach (80 km)
1533.47 nm optical line interface unit. The LNW57 supports OC-192 add/drop, UPSR, and BLSR configurations, single- and dual-homing, non-revertive linear and bidirectional 1+1 protection switching, and
VT1.5, STS-1, STS-3(c), STS-12(c), and STS-48(c) signal transport.
The LNW57 circuit pack can cross-connect VTs in any 48 of 192 STS-
1s in the OC-192 signal. The Stratum 3 timing generator and central
TDM switch fabrics are embedded in the OC-192 OLIU.
The LNW57 may occupy Main slots 1 and 2. Fiber access is provided via a pair of LC-type connectors on the LNW57 faceplate.
The LNW57 circuit pack utilizes a “dither tone” to frequency modulate the laser. This technique is used to minimize the effects of Stimulated
Brillouin Scattering (SBS).
At high optical launch powers, SBS can cause an acoustic backscattering phenomenon in fibers. The dither tone effectively broadens the spectrum of the narrow optical pulse, thus raising the threshold power where SBS becomes an issue.
Normally, Lucent recommends that optical output of the OC-192 circuit packs be amplified to no more than +10 dBm. However, with the dither tone circuit incorporated into the LNW57, optical
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
4 - 3 1
Circuit Pack Descriptions
Product Description
amplification of this circuit pack to much higher power levels is acceptable.
For fibers carrying multiple wavelengths in DWDM systems, it should be noted that the individual channel (individual wavelength) power determine the SBS threshold, not the total composite power of all the channels.
OC-192 OLIU (LNW58)
The OC-192 OLIU (LNW58) circuit pack is a short reach 1310 nm optical line interface unit. The LNW58 supports OC-192 add/drop,
UPSR, and BLSR configurations, single- and dual-homing, nonrevertive linear and bidirectional 1+1 protection switching, and VT1.5,
STS-1, STS-3(c), STS-12(c), and STS-48(c) signal transport. The
LNW58 circuit pack can cross-connect VTs in any 48 of 192 STS-1s in the OC-192 signal. The Stratum 3 timing generator and central TDM switch fabrics are embedded in the OC-192 OLIU.
The LNW58 may occupy Main slots 1 and 2. Fiber access is provided via a pair of LC-type connectors on the LNW58 faceplate.
OC-192 OLIU (LNW59
—
R7.0)
2 port OC-192 VLF Mains (LNW59) support OC-192 add/drop, UPSR, and BLSR configurations, single- and dual-homing, and revertive or non-revertive linear 1+1 protection switching. The LNW59 provides 2 ports capable of supporting 1.3SR1, 1.5IR2, and 1.5LR2 XFPs. It can also function headlessly (with no optics), similar to the LNW80.
For overall capacity, the LNW59 boasts a 20G optical main with a
240G centralized STS switch fabric, 30G centralized VT termination capacity, and 40G VT switch fabric. When DMX is equipped with the
LNW59 VLF Main, all switching takes place on the LNW59. The switch fabrics on the low-speed, tributary optical circuit packs are disabled. The LNW59 further upgrades the shelf’s overall capacity by enabling the Function and Growth slots to house circuit packs with up to 10G bandwidth.
The LNW59 also enables true 0x1 operation amongst the tributary slots. It also enables hairpin cross-connections between unprotected
0x1 interfaces located in the same Function or Growth Unit.
LNW59 supports STS-1, STS-3c, STS-12c, and STS-48c signal transport. The OC-192 OLIU can cross-connect VTs in any 192 STS-
1s. LNW59s may occupy Main slots 1 and 2.
All tributary circuit packs, with the exception of the LNW6 and LNW7 are supported by the LNW59.
...........................................................................................................................................................................................................................................................
4 - 3 2
365-372-300
Issue 8.0, September 2006
Circuit Pack Descriptions
Product Description
OC-192 OLIU (LNW60)
The LNW60 is based on the LNW57 described above. It has the same characteristics, capabilities, and specifications as the LNW57, but it also includes an on-board, integrated optical amplifier. When the onboard amplifier is in use, the LNW60 is capable of bridging spans of up to 127 km. The LNW60 presents the possibility of savings in CAPEX,
OPEX (no separate management for external optical amplifier required), and space.
OC-192 OLIU (LNW555)
The OC-192 OLIU (LNW555) circuit pack is a long reach (80 km)
1533.47 nm optical line interface unit. The LNW555 supports OC-192 add/drop, UPSR, and BLSR configurations, single- and dual-homing, non-revertive linear and bidirectional 1+1 protection switching, and
VT1.5, STS-1, STS-3(c), STS-12(c), and STS-48(c) signal transport.
The LNW555 circuit pack can cross-connect VTs in any 48 of 192
STS-1s in the OC-192 signal. The Stratum 3 timing generator and central TDM switch fabrics are embedded in the OC-192 OLIU.
The LNW555 may occupy Main slots 1 and 2. Fiber access is provided via a pair of LC-type connectors on the LNW555 faceplate.
OC-192 OLIU (LNW523/527/
LNW554)
The OC-192 OLIU (LNW523/527/554) circuit pack is a DWDM optical line interface units. These DWDM packs support OC-192 add/ drop, UPSR, and BLSR configurations, single- and dual-homing, nonrevertive linear and bidirectional 1+1 protection switching, and VT1.5,
STS-1, STS-3(c), STS-12(c), and STS-48(c) signal transport. These circuit packs can cross-connect VTs in any 48 of 192 STS-1s in the
OC-192 signal. The Stratum 3 timing generator and central TDM switch fabrics are embedded in the OC-192 OLIU.
The LNW523/527/554 may occupy Main slots 1 and 2. Fiber access is provided via a pair of LC-type connectors on the LNW527/554 faceplate.
The LNW523/527/554 employ tunable lasers that support 4 separate frequencies on each of the three packs. The LNW523/527/554 lasers can be made to transmit different frequencies. This feature offers obvious advantages to single frequency circuit packs in that one pack may be ordered and used to support a variety of frequency requirements. Packs can be reused in new applications requiring different frequencies and thus the need to order new packs simply to support different frequencies can, in some cases, be avoided.
The LNW523 is being DA’d and will no longer be available as of
6/30/07.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
4 - 3 3
Circuit Pack Descriptions
Product Description
GbE Private Line (LNW63)
The LNW63 provides 4 PTM ports that can be equipped with
1000BASE-SX/LX/ZX single mode PTMs. Beginning in R7.0,
LNW63 supports an Electrical 100/1000BASE-TX PTM in all ports, though only the 1000BASE-TX rate is supported on the LNW63. The
LNW63 provides data transport at the rate of 1000 Mbps using standard encapsulation according to ANSI T1X1.5/2000-024R4 (ITU
G.7041), and standard STS-1 virtual concatenation according to ITU
G.707.
The LNW63 contains 4 internal 1000 Mbps WAN ports supporting enhanced private line services such as low-order virtual concatenation and Link Capacity Adjustment Scheme (LCAS). The LNW63 and
PTM optics are also OSP hardened for outside plant applications. The
LNW63 is an unprotected pack.
Prior to Release 7.0, LNW63 packs could only be placed in Slot 1 of any function group or growth slot in the shelf (A1-G1) and DMX supported a total add/drop capacity of 20 private line GbE ports if all slots are equipped with LNW63 circuit packs.
When DMX is equipped with VLF Main (LNW59) packs, Ethernet packs can occupy both Slot 1 and 2 of a Function or Growth Unit
(where applicable). With VLF Mains and all tributary slots populated with LNW63 packs, DMX provides a total add/drop capacity of 40 private line GbE ports.
Prior to Release 7.0 (and when VLF Mains are not used), if the LNW63 circuit packs occupy slot 1 of a Function Unit group, slot 2 must be populated with an apparatus blank.
...........................................................................................................................................................................................................................................................
4 - 3 4
365-372-300
Issue 8.0, September 2006
Circuit Pack Descriptions
Product Description
10/100T (LNW66) 100BASE-
TX ethernet interface
The 10/100T circuit pack has 24 ports and provides data transport at the rate of 10/100 Mbps using standard ethernet switching IEEE 802.1, standard encapsulation according to ANSI T1X1.5/2000-024R4 (ITU
G.7041), and standard STS-1 virtual concatenation according to ITU
G.707. The LNW66 can transmit signals across spans as long as 100 meters. Each LNW66 circuit pack can support 1 packet ring. The
LNW66 is an unprotected pack.
The 10/100T may occupy slot 1 of Function Unit groups A, B, C, and
D, and 96 10/100T ports are addressable when four Function Unit groups are equipped with LNW66 circuit packs. When the LNW66 circuit packs occupy slot 1 of a Function Unit group, slot 2 must be populated with an apparatus blank.
GbE Private Line (LNW64)
Ethernet interface (R7.0)
The LNW64 provides 8 private line, PTM (also known as SFP) GbE ports. The ports can be populated with 8 1000BASE-SX/LX/ZX PTMs or 8 100/1000BASE-TX electrical PTMs, though only 1000BASE-TX rates are supported on the LNW64. LNW64 can also support a mix of 4 electrical and 4 optical PTMs. The LNW64 contains 8 internal VCG ports supporting enhanced private line services such as low-order virtual concatenation (VT1.5) and Link Capacity Adjustment Scheme
(LCAS).
LNW64 is OSP hardened and can only be used with VLF Mains
(LNW59).
LNW64 supports STS-1 and STS-3c cross-connections with or without
VCAT, and STS-12c cross-connections without VCAT. All ports are capable of transmitting at wire speed (1000 Mbps) simultaneously, making full capacity of the pack 168 STS-1s. With VLF Mains,
LNW64 can occupy both slots 1 and 2 of a Function/Growth unit, making the total capacity of a systems fully populated with LNW64s,
80 GbE private line ports.
10/100T (LNW71) Private
Line Ethernet interface
The LNW71 circuit pack conforms to the same specifications as the
LNW66 described above. Yet, rather than supporting packet ring transport (like the LNW66), the LNW71 circuit pack is designed specifically to support Fast Ethernet Private Line applications. Each
LNW71 circuit pack can support 24 private lines. The LNW71 can also support STS-3(c) cross connections instead of virtual concatenation.
The 10/100T-PL may occupy slot 1 of Function Unit groups A, B, C, and D, and 96 10/100T ports are addressable when four Function Unit groups are equipped with LNW71 circuit packs. When the LNW71
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
4 - 3 5
Circuit Pack Descriptions
Product Description
1000BASE-SX (LNW67) optical Ethernet interface
circuit packs occupy slot 1 of a Function Unit group, slot 2 must be populated with an apparatus blank.
The LNW71 is being DA’d and will no longer be available as of 3/1/08.
This 2-port Ethernet interface provides short-reach high-speed optical data transport at the rate of 1 Gb/s using standard ethernet switching
IEEE 802.1, standard encapsulation according to ANSI T1X1.5/2000-
024R4 (ITU G.7041), and standard STS-1 virtual concatenation according to ITU G.707.
The LNW67 is an unprotected pack. Fiber access is provided by two
LC-type connector pairs on the LNW67 faceplate. The LNW67 transmits signals at a wavelength of 850nm. The LNW67 requires the use of multimode fiber cable. Each LNW67 circuit pack can support 2 packet rings or 2 GbE private lines (protected or unprotected).
Prior to Release 7.0, LNW67 packs could only be placed in Slot 1 of any function group or growth slot in the shelf (A1-G1) and DMX supported a total add/drop capacity of 10 optical GbE ports if all slots are equipped with LNW67 circuit packs.
When DMX is equipped with VLF Main (LNW59) packs, Ethernet packs can occupy both Slot 1 and 2 of a Function or Growth Unit
(where applicable). With VLF Mains and all tributary slots populated with LNW67 packs, DMX provides a total add/drop capacity of 20 optical GbE ports.
Prior to Release 7.0 (and when VLF Mains are not used), if the LNW67 circuit packs occupy slot 1 of a Function Unit group, slot 2 must be populated with an apparatus blank.
The LNW67 is being DA’d and will no longer be available as of 3/1/08.
1000BASE-LX (LNW68) optical Ethernet interface
While providing the same functionality as the 1G SX interface, the
LNW68 supports long-reach optics. LNW68 transmits signals at a wavelength of 1310nm. The LNW68 requires the use of single-mode fiber cable. Each LNW68 circuit pack can support 2 packet rings. For more information on LNW68, please refer to the section entitled
Ethernet/Data Optical Specifications, in Chapter 10.
The LNW68 is being DA’d and will no longer be available as of 3/1/08.
...........................................................................................................................................................................................................................................................
4 - 3 6
365-372-300
Issue 8.0, September 2006
Circuit Pack Descriptions
Product Description
1000BASE-X/100BASE-LX
(LNW70) switched Ethernet interface
The LNW70 circuit pack provides four 1000BASE-X (SX, LX, and/or
ZX— very long reach 80km), IEEE 802.3-compliant (1000Mbps) GbE interfaces and four 100BASE-LX IEEE 802.3-compliant (100 Mbps) fast Ethernet interfaces. The LNW70 circuit pack performs protocol transparent filtering and bridging of incoming media access control
(MAC) frames. MAC frames with a destination address on the local bus are filtered by the LNW70 to prevent unnecessary transmission of frames over the wide area network (WAN). The LNW70 is not equipment protected, however, protection is provided via SONET
UPSR/BLSR or through the IEEE 802.1w (or 802.1d) spanning tree algorithm.
The LNW70 can also use electrical PTMs that are provisionable to support either 100BASE-T or 1000BASE-T traffic. The electrical
PTMs can occupy ports 1-4.
The LNW70 uses standard Ethernet switching (IEEE 802.1), standard encapsulation according to ANSI T1X1.5/2000-024R4 (ITU G.7041), and standard STS-1 virtual concatenation according to ITU G.707.
Fiber access is provided by LC-type connector pairs on the LNW70 faceplate.
The LNW70 is an unprotected pack by default. R7.0 incorporates support of Link Aggregation on LNW70 LAN ports, which can be used to provide facility protection. For more information on Link
Aggregation, refer to Appendix A.
Prior to R7.0, the LNW70 could only occupy slot 1 of any Function
Unit group on the shelf (including Growth slots), and up to 20
1000BASE-X and 20 100BASE-LX ports were addressable when all
Function Unit groups are equipped with LNW70 circuit packs.
When DMX is equipped with VLF Main (LNW59) packs, Ethernet packs can occupy both Slot 1 and 2 of a Function or Growth Unit
(where applicable). With VLF Mains and all tributary slots populated with LNW70 packs, up to 40 1000BASE-X and 40 100BASE-LX ports are addressable.
Prior to Release 7.0 (and when VLF Mains are not used), if the LNW70 circuit packs occupy slot 1 of a Function Unit group, slot 2 must be populated with an apparatus blank.
The LNW70 features Pluggable Transmission Module (PTM) electrical and optical interfaces. PTMs are “pluggable” in the sense that they can be plugged into a circuit pack as they become necessary. This allows customers to grow their network incrementaly, only realizing the full cost for optics as the need to provision service on (and thus receive
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
4 - 3 7
Circuit Pack Descriptions
Product Description
revenue from) them becomes necessary. LNW70 packs are purchased and shipped with no ports populated with functioning optics. The ports remain empty until the customer decides to place interfaces in them.
4- ports are available for 1000BASE-X (SX and/or LX) optics or 100/
1000BASE-TX electrical interfaces and 4 ports are available for
100BASE-LX optics.
100Mb/GbE Electrical PTM for the LNW70 (R6.0)
The LNW70 now supports a dual function electrical PTM that is provisionable for 100 or 1000 Mbps traffic. It conforms to the
IEEE802.3 standards for 100BASE-T and 1000BASE-T in its respective settings (IEEE802.3z and IEE802.3ab). Connectivity is provided for an RJ-45 Cat 5 cable and the PTM has a maximum span length of 100 meters.
100BASE-LX/100BASE-TX
(LNW74) optical Fast
Ethernet interface
This 24-port Ethernet interface provides 8-ports for optical 100BASE-
LX transport at 100 Mbps using standard ethernet switching IEEE
802.1, standard encapsulation according to ANSI T1X1.5/2000-024R4
(ITU G.7041), and standard STS-1 and VT virtual concatenation according to ITU G.707. The LNW74 also provides 16 electrical ports for the 10/100BASE-TX interfaces. These electrical ports transmit at
10/100 Mbps using standard ethernet switching IEEE 802.1, standard encapsulation according to ANSI T1X1.5/2000-024R4 (ITU G.7041), and standard STS-1 and VT virtual concatenation according to ITU
G.707. The LNW74 electrical interfaces can transmit signals across spans as long as 100 meters. The LNW74 is an unprotected pack and is
OSP hardened.
The LNW74 circuit pack is designed specifically to support Fast
Ethernet Private Line applications. Each LNW74 circuit pack can support 24 private lines. The LNW74 can also support STS-3(c) cross connections instead of virtual concatenation.
Prior to Release 7.0, LNW74 could only occupy slot 1 of any Function
Unit group on the shelf (including Growth slots), and up to 40
100BASE-LX ports and 64 10/100BASE-TX ports were addressable when all Function Unit groups are equipped with LNW74 circuit packs.
When used in the Growth slot, only the optical ports can be used.
In R7.0, with use of true 0x1 and LNW59 VLF Main packs, Ethernet packs can be installed in either slot 1 or 2 of Function Unit or Growth groups. DMX does not allow electrical interface packs to occupy adjacent slots within the same Function or Growth unit next to other electrical interface packs. Therefore, two LNW74s can not be installed within the same group. However, beginning in R7.0 (and when VLF
...........................................................................................................................................................................................................................................................
4 - 3 8
365-372-300
Issue 8.0, September 2006
Circuit Pack Descriptions
Product Description
Mains are used), LNW74 can be installed next to another optical TDM or Ethernet pack with in the same group (ex. LNW74 and LNW67 or
LNW32).
Prior to Release 7.0 (and when VLF Mains are not used), if the LNW74 circuit packs occupy slot 1 of a Function Unit group, slot 2 must be populated with an apparatus blank.
The LNW74 features Pluggable Transmission Module (PTM) optics for all 100BASE-LX interfaces. PTM optics are “pluggable” in the sense that they can be plugged into a circuit pack as they become necessary. This allows customers to grow their network incrementally, only realizing the full cost for optics as the need to provision service on
(and thus receive revenue from) them becomes necessary. LNW74 packs are purchased and shipped with no ports populated with functioning optics. The ports remain empty until the customer decides to place optics in them. 8 ports are available for 100BASE-LX optics.
There are 24 internal WAN ports (capable of transmitting signals to the
MAIN circuit packs) in the LNW74 circuit pack.
FC-DATA Optical SAN interface (LNW73 and
LNW73C- R7.0)
The LNW73 and LNW73C (R7.0) are 4-port Storage Area Networking
(SAN) interface cards designed to facilitate SAN distance extensions via the DMX platform using GFP-T (G.7041). These cards employ standard encapsulation according to ANSI T1X1.5/2000-024R4 (ITU
G.7041), and standard STS-1 and VT virtual concatenation according to ITU G.707. For extended FC/FICON interfaces, the LNW73/73c also supports buffer_to_buffer credit management spoofing consistent with ANSI T11 FC-BB-3_GFPT draft standard.
They utilize PTM optics to provide the option of FICON, ESCON, or
Fibre-channel interfaces natively on the DMX shelf. Each pack must be equipped with only one type of PTM (FICON/FC or ESCON). The
LNW73/73c can operate at 1 Gbps or 2 Gbps and in either
Asynchronous or Synchronous transmission modes. When operating in async Fibre Channel (FC) mode, 2 ports are available at 2Gbps FC, or 4 ports at 1Gbps FC, or 1 port at 2Gbps FC and 2 ports of 1Gbps FC.
When operating in synchronous FC mode, 1 port is available at 2Gbps
FC, or 2 at 1Gbps FC.
While the capacity of each port is 2Gbps, the true capacity of each port is relative to the type of PTM it is equipped with. For ESCON traffic, the PTM ports have a capacity of 200 Mbps. The 2Gbps capacity of the ports is sufficient to support FC2G and FICON Express.
While the LNW73 and 73C do support LCAS, the LNW73 only uses
LCAS with asynchronous FC traffic.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
4 - 3 9
Circuit Pack Descriptions
Product Description
The LNW73C differs from the LNW73 in that it enables compression of SAN traffic.
The R7.0 implementation of SAN compression enables a high throughput of up to two full-line rate FC-2G interfaces in a single pack.
The LNW73C is able to compress asychronous Fibre Channel traffic and conserve up to 50% of bandwidth versus uncompressed asynchronous FC traffic in typical applications.
Compression for asynchronous FC traffic is pre-standard and will be standardized by FC-BB-4. The R6.0 implementation of SAN compression enables a high throughput of up to two full-line rate FC-
2G interfaces in a single pack.
Prior to R7.0, the LNW73/73c could only occupy slot 1 of any
Function Unit group on the shelf (including Growth slots). When DMX is equipped with VLF Main (LNW59) packs, FC-DATA packs can occupy both Slot 1 and 2 of a Function or Growth Unit (where applicable).
Prior to Release 7.0 (and when VLF Mains are not used), if the LNW70 circuit packs occupy slot 1 of a Function Unit group, slot 2 must be populated with an apparatus blank.
1000BASE-X/100BASE-LX
(LNW78) RPR Ethernet interface
This 8-port Ethernet interface provides 4-ports for short-reach and/or long-reach high-speed optical data transport at the rate of 1 Gb/s and
4-ports for optical 100BASE-LX transport at 100 Mbps. The first 4 ports (1-4) are for the GbE traffic (ports 3 and 4 are not available in
R7.0) and the second 4 ports (5-8) are for FE traffic. The LNW78 utilizes PTM optics, allowing you to equip additional ports as necessary. In R7.0, LNW78 adds support for the electrical 100/
1000BASE-TX, electrical Ethernet PTM. This PTM may only occupy ports 1 and 2 of the pack. The LNW78 also supports similar port, switching, and traffic management capabilities as the LNW70.
The LNW78 supports standards compliant RPR switching per IEEE
802.17. LNW78 will support one RPR instance in R6.0 and two in the future. The LNW78 provides two internal Virtual Concatenation Group
(VCG) WAN ports (will support 4 in the future) with a total capacity of
2.5 Gbps capacity for Ethernet RPR traffic (24 STS-1s in each direction).
Beginning in R7.0, VCG ports 17-22 available to provide EoS connectivity. This feature allows EoS port connectivity to RPR ring interfaces via the faceplate of the LNW78 and/or hairpin crossconnects. Interconnection of multiple RPR rings on the same shelf or
...........................................................................................................................................................................................................................................................
4 - 4 0
365-372-300
Issue 8.0, September 2006
Circuit Pack Descriptions
Product Description
separate shelf using EoS VCGs is also supported. Finally, EoS traffic can be managed with QoS support on EoS VCGs.
Prior to R7.0, LNW78 packs could only be placed in Slot 1 of any function group or growth slot in the shelf (A1-G1) and DMX supported a total add/drop capacity of 10 RPR GbE ports and 20 RPR FE ports if all slots were equipped with LNW78 circuit packs.
Beginning in R7.0, with the use of true 0x1 and the LNW59 VLF Main,
LNW78 can occupy slots 1 and 2 of a Function or Growth group. This can increase the overall capacity of the system to 20 RPR GbE (optical only) ports and 20 RPR FE (optical only) ports per shelf.
Prior to Release 7.0 (and when VLF Mains are not used), if the LNW78 circuit packs occupy slot 1 of a Function Unit group, slot 2 must be populated with an apparatus blank.
Detectable blank circuit packs
DMX supports detectable blank circuit packs: LNW98 in unequipped
Function and Growth slots, LNW97 in an unequipped M2.
The WaveStar
®
CIT reports the presence of a detectable blank in a slot by displaying a blank faceplate graphic instead of an empty slot graphic. No alarms are associated with the insertion or removal of the detectable blank.
Electric Continuity Test
Tool (LNW94)
DMX supports a circuit pack designed to aid technicians in the installation and maintenance of Electrical interfaces and cables. The
Electrical Continuity Test Tool (LNW94) can be placed in any
Function slot on the DMX shelf (NOT including Growth Slots). It is used to test the cables which will be connected to DS1, DS3, or
Ethernet electrical interfaces. LNW94 tests the integrity of electrical cables to both identify where trouble exists and which cables or DSX panels are faulty prior to installation and turn up.
In-service Electric
Continuity Test Tool
(LNW93)
The In-service Electrical Continuity Test Tool (LNW93) test circuit pack is used for upgrades in the DMX high capacity shelf. An inservice shelf might have a function unit with low capacity DS1 (LNW6 or 7) or DS3 (LNW16) packs. When these packs are upgraded with higher capacity packs (DS1, LNW8; DS3, LNW19), as part of the upgrade procedure, new DS1 or DS3 connectorized cables are added to the DSX cross-connect frames and to the DMX shelf. The LNW93 pack is used to test out the new wiring without disrupting traffic on the in-service pack.
The LNW93 is very similar to the LNW94 test tool except that it has no backplane connectors for DS1 ports #1-28 or for DS3 ports #1-12.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
4 - 4 1
Circuit Pack Descriptions
Product Description
Cable Management Bracket
When the LNW93 is plugged in, it makes no contact with the wires on the backplane for those lower ports. Since there is no physical connection, the LNW93 does not interfere with the service of the pack in the other slot of the function unit. The LNW93 tests the integrity of electrical cables to both identify where trouble exists and which cables or DSX panels are faulty prior to installation and turn up of a high density DS1 or DS3 circuit pack.
In the interest of helping customers organize the physical networking in their offices, DMX provides a fiber management bracket that mounts to the apparatus blanks used in the unoccupied slots of the shelf. This bracket has 8 hooks where fibers can be set until the pack to which they will be attached is installed.
The bracket is designed to facilitate the organization and storage of prewired fibers that are expected to carry service to the shelf in the future. These brackets attach to the apparatus blanks via PEM nuts on the faceplate. PEM Nuts or PEM Fasteners are mounted flush on the faceplate. They provide a fixed receptacle to which the bracket can be screwed in.
This feature will be available on the detectable apparatus blanks also, but may be phased in; this would allow visibility via the CIT.
...........................................................................................................................................................................................................................................................
4 - 4 2
365-372-300
Issue 8.0, September 2006
Product Description
Passive Optics Units (POUs)
............................................................................................................................................................................................................................................................
Passive Optics Units
The Passive Optics Units (POUs) are a lower-cost solution to using
DWDM for transmitting large amounts of traffic on one fiber. The shelf fits in a bay frame with DMX. If the POU is used in the same bay frame with DMX, then the number of DMX shelves in that bay frame is limited to three. The POUs do not need any power supply or management system.
POU shelves are available to support the following applications:
• Dual optical add-drop module (OADM): 1, 2, or 4 wavelengths
• Dual optical add-drop module (OADM): one 1310 nm port and four 1550 nm ports
• 16 unidirectional/bidirectional wavelengths: MUX or DMUX
• 32 wavelengths using 16 unidirectional/bidirectional wavelengths
(MUX or DMUX) with a wavelength interleaver used to add another 16 wavelengths: MUXINT or DMUXINT
The following figure shows the POU shelves.
Figure 4-3 Passive Optics Unit (POU) Shelves (DWDM Filter
Units): MUX/DMUX
Common
Lucent Technologies nc-dmx-103
The dimensions of the passive optical unit (POU) are:
Height (mm/inches)
74/2.913
Width (mm/inches)
498/19.606
Depth (mm/inches)
378.64/14.907
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
4 - 4 3
Passive Optics Units (POUs)
Product Description
POU Versions
As the variety of applications listed above suggests, there are various versions of the POU, each designed to maximize functionality in a variety of deployment scenarios. The bulleted list below details the various forms of POUs:
• 16 Channel MUX or DMUX (odd numbered channels): This POU supports unidirectional and bidirectional transmission systems.
• 16 Channel MUX or DMUX with Interleaver (even numbered channels): This POU supports unidirectional and bidirectional transmission systems, and includes an interleaver to support 16 additional channels.
• Dual 1-Channel Optical Add Drop: This POU supports unidirectional transmission systems and can add/drop one channel from a DWDM line carrying up to 32 different channels.
• Dual 2-Channel Optical Add Drop: This POU supports unidirectional transmission systems and can add/drop two channels from a DWDM line carrying up to 32 different channels.
• Dual 4-Channel Optical Add Drop: This POU supports unidirectional transmission systems and can add/drop four channels from a DWDM line carrying up to 32 different channels.
• Dual 1310 + 4x1550 MUX/DMUX: This POU provides one I/O port for 1310 nm signals and four I/O ports for 1550 nm signals.
This POU supports unidirectional transmission systems and can
MUX or DMUX a 1310 channel and four 1550 bands to/from a
DWDM line.
Important!
The last four bulleted items in the list above describe the various OADMs and MUX/DMUX as “Dual”.
“Dual” is in reference to the fact that each of these specific POUs are comprised of two complete sets of OADMs or MUX/DMUX units. Thus, the dual 1-channel OADM POU contains 2 OADMs, enabling it to support 1 add/drop in each direction.
...........................................................................................................................................................................................................................................................
4 - 4 4
365-372-300
Issue 8.0, September 2006
Passive Optics Units (POUs)
Product Description
The following figure shows a diagram of transmission with up to 32 wavelengths (channels) being received and passed-through one of the
Add/Drop units. Also, the diagram shows how 1, 2, or 4 wavelengths can be added and/or dropped from a passive DWDM OC-48/192 line using the Add/Drop Units.
Figure 4-4 Add/Drop Unit
Add/Drop Unit
Up to 32
Wavelengths In
Up to 32
Wavelengths Out
1,2, or 4 OC-48/192
Wavelengths Added/Dropped
(# of dropped channels
= # of added channels) nc-dmx-166
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
4 - 4 5
Passive Optics Units (POUs)
Product Description
The following figure shows a diagram of transmission with 16 lines transmitting at one end of the fiber and 16 lines receiving at the other end. The 16 port units on each side of transmission may be a combination of OC-192 DWDM OLIUs and/or OC-48 DWDM OLIUs.
Each OLIU is equipped with a bidirectional port (both transmit and receive). The fiber between the two POUs (DWDM Filter Units) on the upper portion of the figure is unidirectional in the east direction. The fiber between the two Passive Optics Shelves on the lower portion of the figure is unidirectional in the west direction. Another Passive
Optics Shelf, with a wavelength interleaver, can be added to transport
32 wavelengths in each direction at the OC-192 or OC-48 rate on one fiber.
Figure 4-5 MUX/DMUX Passive Optics Shelf (16 Transmit at One
End, 16 Receive at the Other End)
16 MUX 16 DMUX
16 OC48 DWDM and / or
OC192 DWDM
Circuit packs
3
2
1
1 Unidirectional
Fiber
16 OC48 DWDM and / or
OC192 DWDM
Circuit packs
1
2
3
16 DMUX
16 MUX
14
15
16
14
15
16
1 Unidirectional
Fiber wbwm02021
...........................................................................................................................................................................................................................................................
4 - 4 6
365-372-300
Issue 8.0, September 2006
Passive Optics Units (POUs)
Product Description
The following figure shows a diagram of bidirectional transmission with eight lines transmitting at one end of the fiber and eight lines receiving at the other end. This is the same POU pictured above, except that it is being used in a bidirectional application. The eight port units on each side of transmission may be a combination of OC-192 DWDM
OLIUs and/or OC-48 DWDM OLIUs. Each OLIU is equipped with a bidirectional port (both transmit and receive). The fiber between the two POU shelves (DWDM filter unit box) is bidirectional (transmit and receive).
Figure 4-6 MUX/DMUX Passive Optics Shelf (8 Transmit and 8
Receive at Each End)
8 Mux 8 Demux
8 OC48 DWDM and / or
OC192 DWDM
Circuit packs
8 OC48 DWDM and / or
OC192 DWDM
Circuit packs
8
7
6
5
4
3
2
1
3
4
1
2
7
8
5
6
3
4
1
2
5
6
7
8
8 Demux
1 Bidirectional
Fiber
8 Mux
4
5
6
7
8
2
3
5
6
7
3
4
1
2
8
1
1
2
3
4
5
6
7
8 wbwm02020
Important!
This figure assumes a full set of 8 bidirectional point-to-point cross-connections.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
4 - 4 7
Product Description
External Optical Amplifiers
............................................................................................................................................................................................................................................................
Overview
The Lucent external optical amplifier provides service providers, system integrators, and network equipment manufacturers with one of the key technologies needed to build next generation DWDM and
OADM networks. With the optical amplifier, operators enhance system performance while minimizing capital expenditures.
The optical amplifier can be configured to provide variable gain between 13 dB and 22 dB. This enables users to optimize optical transmission performance as needs grow. After gain setting is provisioned, the amplifier dynamically controls and maintains signal levels even as the number of amplified wavelengths change.
The amplifier features dynamic transient suppression and gain flattening across C-band to reduce the likelihood of data errors, channel outage, and signal degradation. In dynamic metro access networks or long-haul optical networks, these features allow service providers to provision and deliver reliable wavelength services to their end customers on demand.
The external optical amplifiers are available in front access and rear access versions.
The figure below shows the front access version of the external optical
amplifier, and Figure 4-8 shows the rear access version of the external
optical amplifier.
Figure 4-7 Optical Amplifier (Front Access)
Input
Port
Output
Port
Status
LEDs
Product
Label
RJ45 Alarm
Relay Contact
ESD
Jack
-48VA
-48RTNA
-48VA
-48RTNA
Output
Monitor
Laser
Warning
POWER
FAIL
LOS
Lucent Technologies
RS-232
ALARM OUT
LAN
-48VA
-48RTNA
RS-232
Craft Port
RJ45 LAN Port -48VB
-48RTNB
MA-DMX-297
...........................................................................................................................................................................................................................................................
4 - 4 8
365-372-300
Issue 8.0, September 2006
External Optical Amplifiers
Product Description
Figure 4-8 Optical Amplifier (Rear Access)
Input
Port
Output
Port
Status
LEDs
POWER
FAIL
LOS
Lucent Technologies
Laser
Warning
Output
Monitor
RS-232
Craft Port
ESD
Jack
Product
Label
MA-DMX-298
Interfaces
The optical amplifiers provide a 10/100 Mbps and an RS-232 port for operations and maintenance communications (similar to DMX). The optical amplifier continuously monitors its own electrical and optical performance. If operating parameters exceed user-specified thresholds, autonomous alarms are reported.
The optical amplifier may be managed by any of the following means:
• Simple Network Management Protocol (SNMP Version 1 and 2c)
• TL1 messages (GR-833 CORE)
• File Transfer Protocol (FTP) (RFC 956)
• Alarm relay contact closures.
For more information about the Lucent external optical amplifiers, consult your account executive.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
4 - 4 9
Product Description
Control
............................................................................................................................................................................................................................................................
Overview
DMX provides extensive control features, accessible through a number of technician and operations system (OS) interfaces. In addition to accessing local DMX NEs through direct interfaces, technicians and
OSs can use the operations features supported via the DCC in the optical signals to access remote NEs. Control functions are supported by the SYSCTL circuit pack.
Beginning in R6.0 DMX requires an upgrade to the LNW2 SYSCTL.
The LNW1 supports all software releases prior to R6.0, but the LNW2 must be used for R6.0 and going forward.
Three-tiered operations interface
DMX maintenance procedures are built on three levels of system information and control. The first tier is provided by the LEDs, displays, and push-button switches located on the faceplate of the
SYSCTL circuit pack. The second tier uses a DMX PC-CIT to provision and retrieve detailed reports of performance monitoring, alarm and status, and system configuration for both local and remote
NEs. The third tier uses the OS interfaces such as TL1 and TL1 over
IAO LAN (TCP/IP or OSI) or PC-CIT to monitor performance, gather alarm information, and configure the system. Also, the IAO LAN interfaces provisioned for TCP/IP support software download and provisionable database backup/restore via FTP.
SYSCTL faceplate
The faceplate of the SYSCTL circuit pack contains indicators that provide system-level information and control functions. The condition of the individual transmission circuit packs can be determined using faceplate LEDs.
The figure on the following page, shows the SYSCTL faceplate. There is a 35-segment numeric LED display and three push-button switches for Update/Initialize (UPD/INIT), ACO/test (ACO/TEST), and Select
(SEL) for local operations.
LNW2 also contains two removable Non-volatile Memory (NVM) cards that are separately orderable from the LNW2 card itself (although the SYSCTL does come equipped with two NVM cards). A DMX shelf running R6.0 software will only function properly when it is equipped with a LNW2 contains two fully functioning NVM cards.
...........................................................................................................................................................................................................................................................
4 - 5 0
365-372-300
Issue 8.0, September 2006
Control
Product Description
In addition to the Active and FAULT LED, there are also seven alarm/ status LEDs on the SYSCTL faceplate, listed below. The FAULT LED is lit if the SYSCTL detects its own failure:
• Critical (CR)
• Major (MJ)
• Minor (MN)
• Abnormal (ABN)
• Far End Activity (FE)
• Near End Activity (NE)
• Alarm Cut-Off (ACO)
Figure 4-9 SYSCTL Circuit Pack (LNW2)
SEL
UPD
INT
LAN
CIT
RS
232
NE
ACO
ACO
TST
IND
Active
FAULT
CR
MJ
MN
ABN
FE
Active
CrItical
Minor
Far End
Fault
Major
Abnormal
Near End
ACO
ACO/TST (Push-button)
IND (35 segment
Alphanumeric LED display)
SEL (Switch)
UPD/INIT (Switch)
IAO LAN Port
Serial Port (RS232)
Nc-dmx-009
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
4 - 5 1
Control
Product Description
Embedded operations channel
Access and control extends beyond the local DMX to remote network elements via the SONET section data communications channel (DCC).
Craft interface dialogs and operations messages are exchanged in the
DCC overhead bytes on each OC-3, OC-12, OC-48, and OC-192 interface.
...........................................................................................................................................................................................................................................................
4 - 5 2
365-372-300
Issue 8.0, September 2006
Product Description
Power Specifications
............................................................................................................................................................................................................................................................
Power supply
The following table lists DMX High Capacity shelf power requirements.
Table 4-4 DMX 30 Amp High Capacity Shelf Power Supply
Requirements
Item
Voltage range, all components
Description
-40.0V to -60.0V
Power Feeders two -48V power feeders
[BREAKER (A) and BREAKER (B)]
Circuit Breakers (two per shelf) 30.0 A
The following table lists DMX 20 Amp High Capacity shelf power requirements.
Table 4-5 DMX 20 Amp High Capacity Shelf Power Supply
Requirements
Item
Voltage range, all components
Power Feeders
Description
-40.0V to -60.0V
two -48V power feeders
[BREAKER (A) and BREAKER (B)]
Circuit Breakers (two per shelf) 20.0 A
Circuit breakers
DMX uses on-board power conversion eliminating the need for slots for bulk power converters. Two independent -48V office power feeders
(A and B) enter the shelf through connectors and are filtered and distributed to the circuit packs through circuit breakers. Power conversion is performed through modular power converters located on the circuit packs. In each circuit pack, the feeders are diode ORed, fused, filtered, and regulated by the board-mounted power modules.
This provides the required redundancy in case of the loss of one feeder or circuit breaker. The green Power LEDs located next to each circuit breaker (A and B) indicate power is being fed to the breaker.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
4 - 5 3
Power Specifications
Product Description
Current drains
The following table provides the maximum and average current drain requirements for a shelf if only one feeder is present.
Table 4-6 High-capacity Shelf Current Drains
Shelf Current Drains in Amperes
Typical @
−
48V
DMX High Capacity Shelf 6.3
Maximum
@
−
23.0
48V
Typical
@
−
40V
7.5
Maximum
@
−
40V
27.5
The following table provides the maximum and average current drain requirements for a bay equipped with four high-capacity shelves.
Table 4-7 Bay Current Drains
Bay Current Drains
Typical @
−
48V
Maximum
@
−
48V
25.2
92.0
Typical
@
−
40V
30.0
Maximum
@
−
40V
110.0
Bay equipped with four
DMX High Capacity
Shelves
The following table provides the maximum and typical heat dissipation figures for the High Capacity Shelf.
Table 4-8 High-capacity Shelf Heat Dissipation
Shelf
DMX High Capacity
Heat Dissipation in Watts
Typical @
−
48V
Maximum
@
−
48V
302 1100
Typical
@
−
40V
300
Maximum
@
−
40V
1100
...........................................................................................................................................................................................................................................................
4 - 5 4
365-372-300
Issue 8.0, September 2006
Product Description
DMX 20 Amp Shelf Power Specifications
............................................................................................................................................................................................................................................................
Overview
The table below provides the current drains for various configurations populating the Metropolis
®
DMX Access Multiplexer 20 Amp shelf.
These configurations demonstrate that it is highly unlikely that any configuration available through R6.0 would have a current drain exceeding the maximum power supply of the 20 Amp shelf.
The packs used in these calculations were chosen because they require the greatest power supply of any pack in their individual class (service type). Also, all configurations contain protected network interfaces
(high-speed <HS>). Therefore, these are truly the maximum current drains for the listed configurations.
Configuration Circuit Pack Slot Equipage Current Drain of
Configuration
High-density DS1/E1 shelf:
HS OC-48 with 224DS1/E1s
High-density DS3 shelf:
HS OC-192 with 192 DS3s
Hybrid Shelf:
HS OC-192
1- 2 port GbE pack
2- 48 port DS3 packs
2- 4 port OC-3 packs
2- 2 port OC-12 pack
Max Optical Shelf
HS OC-192 and full set of OC-48 LS
Max data shelf:
HS OC-192
5 GbE packs
Fan + LNW1/2+ 2 LNW77s + 8
LNW8s
Fan + LNW1/2 + 2 LNW55xs +
8 LNW19s
Fan + LNW1/2 + 2 LNW55xs +
1 LNW67 or 68 + 2 LNW192
+ 2 LNW36s + 2 LNW46s
Fan + LNW1/2 + 2 LNW55xs +
10 LNW31s
Fan + LNW1/2 + 2 LNW55xs +
5 LNW67 or 68s
12.07 amps
10.57 amps
9.93 amps
12.95 amps
10.7 amps
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
4 - 5 5
Product Description
Cabling
............................................................................................................................................................................................................................................................
Overview
This section briefly describes cabling information, including the number of particular cables required.
Cable types
The table below lists available cables along with the required number
(if any).
Table 4-9 Cables
Cable Assembly Description
Power
DS1/E1
Quantity per Shelf
1 per shelf
1 per Function Unit housing a
28DS1 circuit pack
—
LNW6/7(as required)
2 per Function Unit housing 56DS1/
E1
—
LNW8
DS3/EC1/TransMUX
12 conductors
DS3/EC1/TransMUX (highcapacity)
24 conductors
LNW93 and LNW94 cable kit
(comcode 848957437)
1 per Function Unit housing a
LNW16 or LNW18 circuit pack (as required)
2 per Function Unit housing a
LNW19/19B or LNW20 circuit pack (as required)
1 per LNW93 or LNW94 Test Pack
(as desired by customer)
3
3
7
Office Alarm
Office Alarm Mult
Miscellaneous Discrete (right angle connector)
Miscellaneous Discrete (straight connector)
LAN 10/100 BaseT (Crossover)
LAN 10/100 BaseT (Straight
Through)
1 (bottom shelf in bay frame only) 4
1 for any adjacent shelves (as required)
1 per shelf (as required), Standard
Shelf only
5
1 per shelf (as required), Highcapacity Shelf only
1 per shelf (as required) Standard and High-capacity Shelf
1 per shelf (as required) Standard and High-capacity Shelf
6
6
See Note
1
2
...........................................................................................................................................................................................................................................................
4 - 5 6
365-372-300
Issue 8.0, September 2006
Cabling
Product Description
Cable Assembly Description
LAN 100 BASE-TX
Sync Timing
PC-CIT Interface
Modem Cable Assembly
Quantity per Shelf
1 per Function Unit (as required)
1 per shelf (as required)
1 per shelf (as required)
1 per shelf (as required), Standard and High-capacity Shelf
See Note
Table notes
1. One cable assembly supports both the -48VA and -48VB main power feeders on the DMX shelf. Cable assemblies are available in 2,4, 6, and 10 AWG cable kits including the required Storey connectors for connection a the shelf. The connectors are also available seperately for customers who choose to supply their own cable.
2.One DS1 Cable Assembly provides one input and one output cable for
28 DS1s, i.e. for one DS1 function group, e.g.: “J1 A OUT” & “J2 A
IN” used on both the standard and high capacity shelf. Two DS1 Cable
Assemblies are required for the high capacity 56DS1 LNW8, i.e. for 2 function groups, e.g.: “J1 A OUT” & “J2 A IN” and “J24 A OUT” &
“J24 A IN”. The DS1 Cable Assembly consists of two separate cables, each containing 28 pairs of 24 gauge shielded cable. On each of the 28 pairs of cable, cable 1 is for input and cable 2 is for output.
3. One DS3/EC1 Cable Assembly (12 conductors) provides one input and one output cable for 12 DS3/EC-1s (LNW16) or TransMUXs
(LNW18), i.e. for one “12DS3/EC-1 or TransMUX” function groups, e.g.: for “J1 A OUT” and “J2 A IN”.
One DS3/EC1 Cable Assembly (24 conductors) provides one input and one output cable for up to 24 signals, i.e. for the first 12 of 24 connectors used for the LNW16 or LNW18 function groups, e.g.: for “J1
A OUT” and “J2 A IN”.
Two assemblies are required for the high capacity 48DS3 (LNW19), e.g.: “J1 A OUT” & “J2 A IN” and “J24 A OUT” & “J24 A IN”.
4. One Office Alarm Cable Assembly is required for the bottom DMX shelf in a bay frame. Other DMX shelves in the bay frame do not require this assembly, but may use the Office Alarm Mult (J13) cables.
5. One Office Alarm Mult Cable Assembly is required for any adjacent
DMX shelves in a bay frame (above the lowest shelf). For example, if four DMX shelves are located in a single 7-foot bay frame, three cable assemblies are required. These cables cannot reach any further than an adjacent shelf.
6. The Crossover cable is used when connecting to a PC. The Straight
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
4 - 5 7
Cabling
Product Description
Through cable is used when connecting with a hub.
7. This cable kit is an accesory to the LNW93 or LNW94 and is meant to aid in testing procedures. It is not critical to the use and function of these packs, but han help ease cabling in testing procedures. The kit contains the folowing cables:
(1) BNC-BNC DS3 3-foot cable
(1) BNC-LCP DS3 3-foot cable
(1) Bantam-Bantam DS1 3-foot cable
(1) RJ45 - RJ45 LAN Patch Cord
(1) DB9-DB9 connector cable for the RS232 port (6 feet)
...........................................................................................................................................................................................................................................................
4 - 5 8
365-372-300
Issue 8.0, September 2006
Cabling
Product Description
LNW70 faceplate cabling guidelines
The LNW63/64/70/78 can use both optical and electrical PTM transceivers. The figure below shows the connections to the electrical
PTM transceivers. The RJ45 cables that connect to the BASE-T-C1 and
FE/GbE Electrical PTM will be directed downward at a 45 o angle. In order to ensure proper cable routing, the copper cables must be above any optical cables/attenuators, etc. that may be installed.
The first four ports of the LNW70 can be used for either optical or electrical PTM transceivers. So, if there’s a plan to have electrical
PTMs in the pack at any point, the user should reserve the first four ports for electrical PTMs and install any optical PTMs in the bottom four sockets. If there is no plan to have electrical PTMs in the pack, optical PTMs may reside in any socket.
For more information on the LNW70 refer to 1000BASE-X/100BASE-
LX (LNW70) switched Ethernet interface (4-37).
For detailed information on all PTMs available, refer to Allowed PTM
Tranceivers (10-109) and the sections that follow.
Figure 4-10 LNW70 Faceplate
MA-DMX4377
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
4 - 5 9
Cabling
Product Description
...........................................................................................................................................................................................................................................................
4 - 6 0
365-372-300
Issue 8.0, September 2006
5 System Planning and
Engineering
Overview
............................................................................................................................................................................................................................................................
Purpose
This section summarizes basic system planning and engineering information to plan procurement and deployment of the DMX Access
Multiplexer. There are a number of considerations that should be kept in mind when planning the DMX’s role in the network. Projected customer requirements will determine initial capacity needed, as well as evolution to higher capacities. The advanced networking capabilities of the DMX offer many economic and planning benefits, and certain guidelines should be followed to maximize these benefits. Physical installation considerations will be guided by the installation location
(central office, uncontrolled, or customer locations). Initial network configuration will determine synchronization requirements.
Synchronization should be planned on a network basis considering items like topology, reliability, internetwork connectivity, and service evolution.
Contents
The following sections are included in this chapter:
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
5 - 1
System Planning and Engineering
Physical Arrangements
Overview
............................................................................................................................................................................................................................................................
Purpose
This section describes the possible physical arrangements of the DMX
Access Multiplexer.
Contents
The following physical arrangement considerations are covered in this section:
Medium and Large Fabric Engineering Rules
Very Large Fabric (VLF) Engineering Rules
...........................................................................................................................................................................................................................................................
5 - 2
365-372-300
Issue 8.0, September 2006
System Planning and Engineering
Shelf Configurations
............................................................................................................................................................................................................................................................
Overview
DMX is designed to provide a vast array of wideband and broadband voice and data services. Therefore, there is great flexibility in the configuration of the shelf. Various combinations of circuit packs may be used for whatever service is desired. The following paragraphs outline the specific packs that may be used in the Function Unit groups for certain applications.
Important!
Please refer to the following section entitled
“Medium Fabric Engineering Rules” for important information regarding the functioning and capacities of circuit packs with the medium-sized switch fabric (such as the LNW48, LNW50,
LNW26B, LNW28, LNW31, LNW77, LNW121B-159B and
LNW421-459).
Refer to the section entitled Very Large Fabric (VLF) Engineering
Rules for important information regarding circuit pack slot equipage and electrical/optical interface compatibility with regard to use of the LNW59 VLF Main packs.
Requirements
DMX has the following shelf configuration requirements:
• The Main Switch Pack (LNW80) may be located in the main M1 and M2 slots for protected service
• OC-12 OLIU LNW48, LNW50, LNW54 must be located in the main M1 and M2 slots for protected service
• OC-48 OLIUs LNW26B, LNW27, LNW28, LNW29, LNW32,
LNW76, LNW77, LNW121B-LNW159B, and LNW221-259 must be located in the main M1 and M2 slots for protected service
• OC-192 OLIUs LNW56, LNW57, LNW58, LNW59, LNW60,
LNW523, LNW527, LNW554, and LNW555 must be located in the main M1 and M2 slots for protected service
• The LNW36, LNW37, and LNW45 (OC-3), LNW46 and LNW49
(OC-12), and LNW31, LNW62, and LNW421-459 (OC-48) packs may be used interchangeably. The Function slots 1 and 2 of a particular group (A, B, C, D, or G) need not be populated with the same pack.
• The service and protection slots of a function unit (for example,
A1 and A2) and growth slots G1 and G2 must contain the same circuit pack type except when running in unprotected scenarios.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
5 - 3
Shelf Configurations
System Planning and Engineering
Beginning in R7.0, with the use of VLF Main packs (LNW59),
DMX supports true 0x1 configurations, wherein slots 1 and 2 of a group can be populated with two working packs of the same kind, or with different working packs (certain restrictions apply).
Whenever a companion slot is left empty, an apparatus blank must be placed in the other slot of that group regardless of what software release or Main packs are installed in the shelf.
• The electrical interface circuit packs (LNW6, LNW7, LNW8,
LNW16, LNW18, LNW19/19B, and LNW20) must be located in function unit slots A - D. Growth slots do not support electrical interface circuit packs. Yet, the LNW20 can be installed in the
Growth slots where it functions in portless mode only. LNW6 and
LNW7 circuit packs are not supported with the use of the LNW59
VLF Main packs.
• Prior to R7.0, the Gigabit Ethernet circuit packs (1G SX, 1G LX, and RPR) must be located in slot 1 of a function unit (including growth slots). The other slot must contain a 177D apparatus blank or an LNW98 detectable blank circuit pack. With R7.0 and later releases, when the VLF Main packs are used, Ethernet packs can be used in both slots of a group. Certain restrictions apply. Refer
Very Large Fabric (VLF) Engineering Rules
.
• Prior to R7.0, the FC-DATA SAN circuit packs (LNW73/73C) must be located in slot 1 of a function unit (including growth slots). The other slot must contain a 177D apparatus blank or an
LNW98 detectable blank circuit pack. With R7.0 and later releases, when the VLF Main packs are used, SAN packs can be used in both slots of a group. Certain restrictions apply. Refer to
Very Large Fabric (VLF) Engineering Rules
• Prior to R7.0, 10/100T (LNW66) and 10/100-PL (LNW71) circuit packs must be located in slot 1 of a function unit. The other slot must contain a 177D apparatus blank or an LNW98 detectable blank circuit pack. Growth slots G1 and G2 do not support the 10/
100T and 10/100-PL circuit packs. With R7.0 and later releases, when the VLF Main packs are used, some Ethernet packs can be used in both slots of a group. Certain restrictions apply. For instance, LNW71 and LNW74 cannot be used for true 0x1 configurations and must be housed in Slot 1 of a function unit or growth group. Refer to
Very Large Fabric (VLF) Engineering Rules
.
• Prior to R7.0, the Fast Ethernet Private Line circuit pack
(LNW74) must be located in slot 1 of a function unit. The other slot must contain a 177D apparatus blank or an LNW98 detectable blank circuit pack. The LNW74 can be used in G1 as well, but only the optical ports will function (true for all Releases). With
...........................................................................................................................................................................................................................................................
5 - 4
365-372-300
Issue 8.0, September 2006
Shelf Configurations
System Planning and Engineering
R7.0 and later releases, when the VLF Main packs are used, some
Ethernet packs can be used in both slots of a group. Certain
Very Large Fabric (VLF) Engineering
• The SYSCTL LNW2 circuit pack must be located in the control
CTL slot.
• An apparatus blank (177D or 177E) or detectable blank circuit pack (LNW97 or LNW98) must be used in every unequipped slot.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
5 - 5
System Planning and Engineering
Shelf Configurations
............................................................................................................................................................................................................................................................
Overview
This section provides lists detailing the kind of circuit packs that can be used to support various applications. Note that the LNW59 (R7.0) VLF
Main pack provides 2 sets of ports on the faceplate. Each set of 2 ports can function independently, meaning that both need not be provisioned for the same application (or e populated with PTMs at all). Therefore, with VLF Mains and R7.0 software, a shelf could be both a BLSR and
UPSR shelf simultaneously (or BLSR and 1+1, 1+1 and UPSR etc).
STS-1/STS-3c/STS-12c/
STS-48c/VT1.5 UPSR shelf
The STS-1/STS-3c/STS-12c/STS-48c/VT1.5 UPSR shelf configuration has OC-12, OC-48, or OC-192 OLIUs in the main M1 and M2 slots and can house the following circuit packs in various combinations:
• 28DS1 (LNW6)
• 28DS1PM (LNW7)
• 56DS1/E1 (LNW8)
• 12DS3/EC-1 (LNW16)
• 48DS3/EC-1 (LNW19/19B)
• 48DS3/EC-1/TMUX (LNW20)
• TMUX (LNW18)
• OC-3 OLIU (LNW36 and LNW37—
4-ports each or LNW45— 8-ports)
• OC-12 OLIU (LNW46— 2-ports or LNW49— 4-ports)
• OC-48 OLIU (LNW31, LNW62, and LNW421 - LNW459)
• 10/100T
• 10/100-PL
• 1000BASE-LX/SX/ZX
• 1000BASE-X/ 100BASE-LX
• 100BASE-LX/ 10/100 BASE-TX
• RPR
• FC-DATA (SAN)
Note that the OC-3/OC-12/OC-48 OLIUs are required for STS-3c/
STS-12c/STS-48c UPSR configurations. The OC-3/OC-12/OC-48
OLIUs can also be used in STS-1/VT1.5 configurations. The LNW62 has 4 ports, all other OC-48 packs have 1 port. For detailed information
...........................................................................................................................................................................................................................................................
5 - 6
365-372-300
Issue 8.0, September 2006
System Planning and Engineering
on circuit packs, including shelf equipage rules and port densities, refer
BLSR shelf
The BLSR shelf configuration has OC48 or OC-192 OLIUs in the main
M1 and M2 slots and the following circuit packs in various combinations:
• 28DS1 (LNW6)
• 28DS1PM (LNW7)
• 56DS1/E1 (LNW8)
• 12DS3/EC-1 (LNW16)
• 48DS3/EC-1 (LNW19/19B)
• 48DS3/EC-1/TMUX (LNW20)
• TMUX (LNW18)
• OC-3 OLIU (LNW36 and LNW37—
4-ports each or LNW45— 8-ports)
• OC-12 OLIU (LNW46— 2-ports or LNW49— 4-ports)
• OC-48 OLIU (LNW31, LNW62, and LNW421 - LNW459)
• 10/100T
• 10/100-PL
• 1000BASE-LX/SX/ZX
• 1000BASE-X/ 100BASE-LX
• 100BASE-LX/ 10/100 BASE-TX
• RPR
• FC-DATA (SAN)
The LNW62 has 4 ports, all other OC-48 packs have 1 port. For detailed information on circuit packs, including shelf equipage rules and port densities, refer to
DCS shelf (Using Main
Switch pack)
The DCS shelf configuration has the Main Switch pack (LNW80) or the VLF Main pack (LNW59) with no PTMs installed in the main M1 and M2 slots and the following circuit packs in various combinations:
• 28DS1 (LNW6)
• 28DS1PM (LNW7)
• 56DS1/E1 (LNW8)
• 12DS3/EC-1 (LNW16)
• 48DS3/EC-1 (LNW19/19B)
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
5 - 7
System Planning and Engineering
• 48DS3/EC-1/TMUX (LNW20)
• TMUX (LNW18)
• OC-3 OLIU (LNW36 and LNW37—
4-ports each or LNW45— 8-ports)
• OC-12 OLIU (LNW46— 2-ports or LNW49— 4-ports)
• OC-48 OLIU (LNW31, LNW62, and LNW421 - LNW459)
• 10/100T
• 10/100-PL
• 1000BASE-LX/SX/ZX
• 1000BASE-X/ 100BASE-LX
• 100BASE-LX/ 10/100 BASE-TX
• RPR
• FC-DATA (SAN)
The LNW62 has 4 ports, all other OC-48 packs have 1 port. For detailed information on circuit packs, including shelf equipage rules and port densities, refer to
OC-12/OC-48/192 linear shelf
The OC-12/48/192 linear shelf configuration has OC-12/48/192 OLIUs in the main M1 and M2 slots and the following circuit packs in various combinations:
• 28DS1 (LNW6)
• 28DS1PM (LNW7)
• 56DS1/E1 (LNW8)
• 12DS3/EC-1 (LNW16)
• 48DS3/EC-1 (LNW19/19B)
• 48DS3/EC-1/TMUX (LNW20)
• TMUX (LNW18)
• OC-3 OLIU (LNW36 and LNW37—
4-ports each or LNW45— 8-ports)
• OC-12 OLIU (LNW46— 2-ports or LNW49— 4-ports)
• OC-48 OLIU (LNW31, LNW62, and LNW421 - LNW459)
• 10/100T
• 10/100-PL
• 1000BASE-LX/SX/ZX
• 1000BASE-X/ 100BASE-LX
...........................................................................................................................................................................................................................................................
5 - 8
365-372-300
Issue 8.0, September 2006
System Planning and Engineering
• 100BASE-LX/ 10/100 BASE-TX
• RPR
• FC-DATA (SAN)
The LNW62 has 4 ports, all other OC-48 packs have 1 port. For detailed information on circuit packs, including shelf equipage rules and port densities, refer to
Single and dual homing shelf
The single homing and dual homing shelf configurations has OC-12,
OC-48 or OC-192 OLIUs in the main M1 and M2 slots and require at least one of the following circuit packs:
• OC-3 OLIU (LNW36 and LNW37—
4-ports each or LNW45— 8-ports)
• OC-12 OLIU (LNW46— 2-ports or LNW49— 4-ports)
• OC-48 OLIU (LNW31)
• OC-48 OLIU (LNW62)
• OC-48 OLIU (LNW421 - LNW459)
If an OC-3 shelf is homing to DMX, the LNW36, LNW37, LNW45 circuit pack must occupy at least one function unit or growth group
(with VLF Main packs (LNW59) and R7.0 software, the other slot of a function unit or growth group can be occupied with a different OLIU or a faceplate-based Ethernet pack). If an OC-12 shelf is homing to DMX, the LNW46 or LNW49 must occupy at least one function unit or growth group. If an OC-48 shelf is homing to DMX, the LNW31,
LNW62, or LNW421 - LNW459 circuit pack must occupy at least one function unit or growth group. It is possible to home to OC-3, OC-12, and/or OC-48 rings on the same shelf. Any other circuit pack may occupy other function units depending on the desired service.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
5 - 9
System Planning and Engineering
Medium and Large Fabric Engineering Rules
............................................................................................................................................................................................................................................................
Overview
This section describes the functionality and limitations resulting from the use of the medium-sized switch fabrics in certain high-speed circuit packs. Use this section to help plan the use of circuit packs in Main slots of the DMX shelf. Because of the smaller switch fabric in these cards, they are less costly, but this smaller switch fabric cannot handle the same volume of cross-connects as the full-sized switch fabric (48
STS-1). The use of these cards therefore results in certain cross-connect restrictions as described below.
Medium Fabric Cards
The table below lists the DMX circuit packs equipped with the medium-sized switch fabric mentioned above.
Table 5-1 Circuit packs with medium sized switch fabric
Circuit Pack Apparatus
Code
Slot(s)
LNW26B M1, M2
Release Comments
OC-48 OLIU
(1 port)
LNW28
LNW77
LNW121B to
LNW159B
LNW48
OC-12 OLIU
(1 port)
LNW50
LNW54
M1, M2
M1, M2
M1, M2
M1, M2
M1, M2
M1, M2
2.0
1.0
High-speed, long reach, 1310nm, 12 STS-1
VT fabric
High-speed, long reach, 1310nm, 12 STS-1
VT fabric
, OSP Hardened
2.0
High-speed, intermediate reach, 1310nm, 12
STS-1 VT fabric
2.0 and 2.1
High-speed 16 DWDM circuit packs. 32 different wavelengths in the 1550 nm range. The
121B series supports 12
STS-1
VT fabric.
3.1
3.1
5.1
High-speed, Intermediate reach. 1310 nm, OSP
Hardened, 12 STS-1 VT fabric
High-speed, Long reach. 1310 nm, OSP
Hardened, 12 STS-1 VT fabric
High-speed, Long reach. 1550 nm, OSP
Hardened, 12 STS-1 VT fabric
...........................................................................................................................................................................................................................................................
5 - 1 0
365-372-300
Issue 8.0, September 2006
System Planning and Engineering
Differences at the Shelf
Level
This sections describes the impact of medium-size fabric cards versus full-size fabric cards at the shelf level.
Shelf with Large-sized Fabric Main Circuit Packs
The figure below shows the DMX shelf with MAIN circuit packs containing 48 STS-1-VT switch fabric. The capabilities of the switch fabric and each function unit are described below the figure.
Figure 5-1 DMX with large fabric Main circuit packs
Main 1
48 STS-VT Fabric
Main 2
48 STS-VT Fabric
FN a
1 2
FN b
1 2
FN g
1 2
FN c
1 2
FN d
1 2
48
STS-1
Electrical
Optical
48
STS-1
Electrical
Optical
48
STS-1
Optical
Only
48
STS-1
Electrical
Optical
48
STS-1
Electrical
Optical
MA-DMX-399
• Function Groups A, B, C, and D are general purpose slots and support all low-speed circuit packs except certain packs associated with R7.0 (LNW62 and LNW64).
• Function Group G is referred to as the growth slot. The growth slot supports only optical, low-speed circuit packs, these includes all of the OC-3/12 & 48 port cards as well as the LNW67 SX GbE
& LNW68 LX GbE cards. Also in release 5.0/5.1, the growth slot supports new Ethernet hardware. The new hardware supported are the LNW70, LNW73, and LNW74 port cards. Certain packs associated with R7.0 are not supported (LNW62 and LNW64).
Growth slots can also house LNW20 TransMUX packs functioning in portless mode.
• All function groups have an STS add/drop capacity of 48 STS-1s.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
5 - 1 1
System Planning and Engineering
Shelf with Medium-sized Fabric Main Circuit Packs
The figure below shows the DMX shelf with MAIN circuit packs containing 12 STS-1-VT switch fabric. The capabilities of the switch fabric and each function unit are described below the figure.
Figure 5-2 DMX with medium fabric Main circuit packs
Main 1
12 STS-VT Fabric
Main 2
12 STS-VT Fabric
FN a
1 2
FN b
1 2
FN g
1 2
FN c
1 2
FN d
1 2
24
STS-1
Electrical
Optical
24
STS-1
Electrical
Optical
48
STS-1
Optical
Only
24
STS-1
Electrical
Optical
48
STS-1
Electrical
Optical
MA-DMX-400
• Function Groups A, B, C, and Dare general purpose slots and support all low-speed circuit packs, except certain packs associated with R7.0 (LNW62 and LNW64).
• Function Group G is referred to as the growth slot. The growth slot supports only optical, low-speed circuit packs, these includes all of the OC-3/12 & 48 port cards as well as the LNW67 SX GbE
& LNW 68 LX GbE cards. Also in release 5.0/5.1, the growth slot will support new Ethernet hardware. The new hardware supported are the LNW70, LNW73, and LNW74 port cards. Certain packs associated with R7.0 are not supported (LNW62 and LNW64).
• Function groups A, B, and C have an STS add/drop capacity of 24
STS-1s. This is a hardware-based restriction imposed by the use of the medium-sized STS switch fabric in the MAIN cards.
• Function groups D and G have an STS add/drop capacity of 48
STS-1s.
...........................................................................................................................................................................................................................................................
5 - 1 2
365-372-300
Issue 8.0, September 2006
System Planning and Engineering
Engineering Restrictions at the Circuit Pack Level
This section describes engineering/cross-connection restrictions relative to the use of medium-sized switch fabric cards.
OC-12 medium fabric (LNW48/50/54)
The LNW48, LNW50, and LNW54 employ a 12 STS-1/VT1.5 switch fabric with the following capacity:
• 784x784 VT matrix
• 216x216 STS matrix
Function Groups A, B, and C support 24 STS-1 add/drop capacity
• Additional pass-through traffic is supported
• Any circuit pack with a capacity of 48 STS-1s is limited to 24
STS-1s (ex. 24 DS-3 add/drop capacity with LNW19)
• 1 virtual concatenation group (VCG) pair is accessible to GbE circuit packs
Function Groups D and G support 48 STS-1 add/drop capacity
• Full add/drop capacity to circuit packs capable of 48 STS-1s
OC-48 medium fabric (LNW26B/LNW28/LNW77, LNW121B-159B)
The OC-48 packs listed above employ a 12 STS-1/VT1.5 switch fabric with the following capacity:
• 784x784 VT matrix
• 288x288 STS matrix
Function Groups A, B, and C support 24 STS-1 add/drop capacity
• Additional pass-through traffic is supported
• Any circuit pack with a capacity of 48 STS-1s is limited to 24
STS-1s (ex. 24 DS-3 add/drop capacity with LNW19)
• 1 virtual concatenation group (VCG) pair is accessible to GbE circuit packs
Function Groups D and G support 48 STS-1 add/drop capacity
• Full add/drop capacity to circuit packs capable of 48 STS-1s
OC-48/192 large fabric (LNW27/29/LNW32/LNW76, LNW221B-
259B, LNW58, LNW527/554/555)
The OC-48/192 packs listed above employ a larger, 48 STS-1/VT1.5 switch fabric with the following capacity:
• 2688x2688 VT matrix
365-372-300
Issue 8.0, September 2006
• 432x432 STS matrix (for OC-48);
720x720 STS matrix (for OC-192)
............................................................................................................................................................................................................................................................
5 - 1 3
System Planning and Engineering
Function Groups A, B, C, D, and G support 48 STS-1 add/drop capacity
• Full add/drop capacity to circuit packs capable of 48 STS-1s
• Two VCG pairs are accessible to GbE circuit packs
Source/Destination
Engineering Rules
Due to hardware limitations in medium-fabric Mains, crossconnections may be denied even though the capacity of the crossconnect fabric has not been exceeded.
The source and destination for VT1.5 cross-connections are designated according to the priorities listed below. In any VT1.5 cross-connect pair, the Function Group (FN) closer to the left will always be the source. Therefore, in any cross-connect that utilizes the Main switch fabric, the Main group will be the source.
Source <<<<<<<<<<<<<<<<
Main<<FNA<<FNB<<FNC<<FND<<FNG
Destination
In addition to the position of the shelf, source/destination demarcation is also determined by the STS number. The lower STS number is the source and the higher STS number is the destination.
Once a cross-connect utilizing a VT1.5 within an STS-1 is established, no part of that STS-1 can be used in a cross-connect to a slot/group on the other side of the shelf. For example, if a VT1.5 from an STS-1 entering the shelf at Function Group B1 (FNB1) was cross-connected to FNA1, another VT1.5 in that same STS-1 could not be cross connected to FNC, FND, or FNG.
Cross-connections made with the LNW6 and LNW7 circuit packs are exceptions to this rule. These packs are always the cross-connect
destination. Hairpin cross-connections between these packs are not allowed.
Intra-port hairpins are supported by DMX. Yet when a DMX is equipped with medium fabric mains, intra-port hairpinns are not allowed.
...........................................................................................................................................................................................................................................................
5 - 1 4
365-372-300
Issue 8.0, September 2006
System Planning and Engineering
Very Large Fabric (VLF) Engineering Rules
............................................................................................................................................................................................................................................................
Overview
This section describes the functionality and limitations relating to circuit pack/slot equipage and electrical/optical port availability when the VLF Main packs introduced in R7.0 are used. Use this section to help plan the use of circuit packs in the Function and Growth units of a shelf equipped with VLF Mains.
VLF Cards
In R7.0 DMX introduces the LNW59 VLF Main circuit pack. In addition to providing 2 OC-192 ports via PTMs (also known as SFPs and/or XFPs), the LNW59 represents a large upgrade to the overall switch fabric capacity of the DMX shelf. This increased capacity makes true 0x1 configurations possible for the first time. Prior to R7.0,
DMX could not host differnt packs within the same Function or
Growth Unit. Use of the VLF Main in R7.0 makes this feature possible, in some cases resulting in double the overall port density for a given interface type.
However, there are certain restrictions with regard to which packs can reside next to each other in the same Function Unit or Growth slot. This section details these restrictions and provides general guidelines for circuit pack/slot equipage with the VLF Mains.
With VLF Mains, all switching and cross-connect functions are centralized on the STS and VT fabrics located on the VLF Main pack.
This is in contrast to shelves equipped with non-VLF Mains, where switching and cross-connection functions are distributed across the
Main (high-speed) and tributary (low-speed) packs/fabrics. When VLF
Mains are used in conjunction with tributary packs that contain their own switch fabrics, the switch fabrics on the tributary packs are automatically disabled.
Tributary packs supported
The VLF Main pack supports all circuit packs available in previous releases of the DMX shelf with the exception of the LNW6 and LNW7
28DS1 packs. Customers requiring DS1 connectivity and VLF Mains must employ the LNW8 56DS1/E1 pack.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
5 - 1 5
System Planning and Engineering
Pack compatibility for unprotected (0x1) configurations
The 0x1 capability allows compatible packs of different types to reside in the same low-speed group. Generally speaking packs which use the rear-access electrical backplane connectors are not compatible with any other packs; that is, they cannot be installed in adjacent slots within the same group. This includes, but is not limited to: LNW19/19B, LNW66,
LNW71, and LNW74.
Certain circuit pack/slot equipage guidelines are the same either VLF or non-VLF Mans are used. The use of electrical ports on the LNW70 ad LNW78 are not restricted when these packs are installed in the
Growth slots because their electrical interfaces are confined to the faceplate only. The electrical interfaces on the LNW71 and LNW74 are backplane only and will not function in the Growth slot. However, the
LNW74 also contains faceplate optical interfaces that will function in the growth slot.
In the following list of compatibility guidelines, “Ethernet” includes
Ethernet and SAN packs, “electrical” not modified by “TDM” refers to any pack that uses rear-access backplane connectors, and “TDM electrical” excludes Ethernet and Data packs. Note that “electrical” does not include Ethernet/Data packs using electrical PTMs.
Important!
The LNW74 can be installed in the Growth slots, but only the optical ports will be functional. Also, the LNW20 may be used in the Growth slots, but it will only function in portless mode.
0x1 Circuit pack/slot compatibility guidelines:
Listed below are circuit pack combinations that are incompatible for
0x1 configurations:
• TDM electrical pack/any other pack
• Any accepted pack/another TDM electrical pack
• 0x1-compatible Ethernet electrical pack/any other electrical pack
All other packs are compatible with each other for 0x1 configurations:
• OLIU/different OLIU
• OLIU/same OLIU
• non-electrical 0x1-compatible Ethernet pack/non-electrical 0x1compatible Ethernet pack
• OLIU/0x1-compatible Ethernet pack (whether electrical or not)
...........................................................................................................................................................................................................................................................
5 - 1 6
365-372-300
Issue 8.0, September 2006
System Planning and Engineering
• electrical 0x1-compatible Ethernet pack/non-electrical 0x1compatible Ethernet pack
Supported combinations of packs within a Function/Growth
Group
The table below summarizes the guidelines detailed above for 0x1 compatible pack combinations within the same group. An OLIU is in
0x1 mode when all ports in the OLIU are set to the 0x1 application.
Table 5-2 0x1 compatible combinations
Slot 2
Rear Access
Mixed Front and Rear
Access
Front Access
Rear Access
Compatible
Circuit Pack Type
Slot 1
Not Compatible
Not Compatible
Mixed Front and Rear
Access
Not Compatible
Not Compatible
Compatible
Front Access
Compatible
Compatible
Compatible
NOTES
1. Front access packs include all OLIUs (Optical Line Interface Units), and the following Ethernet/Data packs: LNW63, LNW64, LNW67,
LNW68, LNW70, LNW73, and LNW78
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
5 - 1 7
Differences at the Shelf
Level
System Planning and Engineering
This section describes the general capabilities and switch fabric capacities of the VLF Main packs.
Shelf with Large-sized Fabric Main Circuit Packs
The figure below shows how the general capabilities of the DMX shelf are enhanced/changed with the use of VLF Main circuit packs
(LNW59).
When the LNW59 VLF Main is installed in a DMX shelf, all switching and cross-connect functionality is centralized on the LNW59 fabrics.
Switching within the fabrics on the low-speed OLIUs is disabled and traffic is routed directly to the STS fabric on the Mains, bypassing any
VT fabric on the low-speed OLIUs.
The LNW59 increases the overall capacity of the shelf with a 240G
STS-1 fabric (4608x4608), 40G VT1.5 fabric (24,192x24,192), and
30G of VT termination capacity (5,376 VTs of UPSR protected 2-way add/drop cross-connections).
Figure 5-3 DMX with VLF Main circuit packs (LNW59)
2 x OC-192 Interfaces per Pack
Support for 2 Protected
1+1, UPSR, BLSR
LNW59
VLF Main
10 Gb per Slot (20 Gb per Fn)
Fn A Fn B Fn G Fn C
LNW59
VLF Main
True 0x1 Functionality Allows
For Flexibility Within a
Function Group:
! Double Density
! Mixing of Services
Fn D
4 x OC-48 Tributary Cards
Total of 192 STS1s
Mixed Interfaces Within a Function Group
2 Independent Interface Types
Enabled by True 0 x 1 Feature
8 x GbE Tributary Cards
Total of 168 STS1s
From Each Port Unit
MA-DMXAPG-040
...........................................................................................................................................................................................................................................................
5 - 1 8
365-372-300
Issue 8.0, September 2006
System Planning and Engineering
• Function Groups A, B, C, and D are general purpose slots and support all low-speed circuit packs (except the LNW6 and
LNW7).
• Function Group G is referred to as the growth slot. The growth slot supports only optical, low-speed circuit packs, these include all of the OC-3/12 & 48 port cards as well as the LNW64,
LNW67, LNW68, LNW70, LNW73/73C, LNW74, and LNW78 port cards. In R7.0, growth slots can also house LNW20
TransMUX packs functioning in portless mode.
• VLF Mains provide up to 10G add/drop capacity to each lowspeed slot in the shelf.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
5 - 1 9
System Planning and Engineering
Network Bay Frames
............................................................................................................................................................................................................................................................
Overview
The DMX can be mounted in frames of both 23-inch and 19-inch widths. 23-inch wide frames available through Lucent include the
ED8C800 (for rear mounting) and the ED8C801 (for front mounting).
Both of these 7-foot frames may accommodate up to four DMX shelves per bay. Yet, when a fuse panel is mounted at the top of one of these 7foot bays, 4 high-capacity shelves will fit. 19-inch wide EIA310-D bay frames are available through a number of third-party suppliers.
Bay arrangements
A standard 7-foot bay arrangement may contain up to four DMX
Access Multiplexers. When a bay frame is fully equipped with four
DMX shelves, a 0.515-inch space must remain open at the bottom of the rack to allow for proper air circulation. DMX shelves should be installed from bottom to top. This arrangement is configured for rear access cabling.
Important!
The high-capacity shelf uses an integral fan unit that comes attached to the DMX high-capacity shelf at the bottom of the shelf. The heat baffle is located at the top of the DMX highcapacity shelf.
...........................................................................................................................................................................................................................................................
5 - 2 0
365-372-300
Issue 8.0, September 2006
Network Bay Frames
System Planning and Engineering
The figure below shows a typical bay arrangement using the highcapacity DMX shelf. Note that the Fan Unit is an integral part of the
DMX high-capacity shelf.
Figure 5-4 Typical Bay Frame Arrangement Using High-capacity
Shelf
Metropolis
®
DMX
High-capacity
Shelf
Integral Fan Unit
Metropolis
®
DMX
High-capacity
Shelf
Integral Fan Unit
Metropolis
®
DMX
High-capacity
Shelf
7
Feet
Integral Fan Unit
Metropolis
®
DMX
High-capacity
Shelf
Integral Fan Unit
0.515 inch for proper air circulation nc-dmx2-026
Important!
When using the high-capacity DMX shelf, 4 shelves can fit in a bay with a fuse panel.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
5 - 2 1
System Planning and Engineering
Typical Bay Arrangement
............................................................................................................................................................................................................................................................
Overview
Up to four DMX high capacity shelves, including fan units, can fit in one 7-foot network bay frame (19 or 23 inches wide).
When a network bay frame is fully equipped with DMX high-capacity shelves, a 0.515-inch space must remain open at the bottom of the frame to allow proper air circulation.
These arrangements meet network equipment-building system (NEBS) central office requirements for bay heat dissipation. If typical arrangements are not used, normal heat flow could be interrupted and adversely affect shelf operation. Fan units must be used to guarantee proper air circulation.
Fan unit
Fan units are required (in all environments) to guarantee proper air circulation. The DMX high capacity shelf includes an integral fan unit.
Adding shelves
Fan filters
The fan unit is equipped with a fan filter. To keep the fan unit operating properly, it is recommended that users routinely change the fan filter every 6 to 9 months.
Shelves can be added incrementally by local technicians (since all cabling is connectorized) if interbay cabling is initially provided for the bay layout. If shelves are incrementally installed, it is recommended that they be installed from bottom to top to simplify bay mult cabling.
However, shelves may be added in any position if proper bay mult cabling is selected.
If a shelf is added above existing non-DMX equipment one heat baffle
(408474799 or 848862181) must be installed between the shelf and the existing equipment.
For detailed information about network bay frame arrangements and installation instructions, refer to the Metropolis
®
DMX Access
Multiplexer, Installation Manual, 365-372-304.
...........................................................................................................................................................................................................................................................
5 - 2 2
365-372-300
Issue 8.0, September 2006
System Planning and Engineering
Cabinet Arrangements
............................................................................................................................................................................................................................................................
Overview
Outside plant (OSP) cabinet configurations are available using the OSP
Hardened Main packs: LNW28, LNW32 (OC-48), LNW48, LNW50, and LNW54 (OC-12) OLIUs. Many of the low-speed (tributary) packs supported by DMX are OSP hardened.
Air Filter in OSP
Environment
Additional Information
The OSP environment may cause false clogged filter alarms. When the shelf is installed in an outside plant cabinet, the cooling air filter must be removed. The filter is not needed when operating in an OSP. This measure will improve air flow and thus enhance cooling performance and equipment life. See the DMX User Operations Guide (
365-372-301
) or Installation Manual (
365-372-304) for instructions to suppress the clogged filter alarm. Suppression of the clogged air filter alarm is required when installing the shelf in an OSP.
Detailed information regarding the installation of all Metropolis
®
DMX products in OSP applications can be found in Appendix D, Physical,
Electrical, and Thermal Compatibility Requirements for OSP
Applications. For more information regarding the OSP capabilities of low-speed packs, refer to Chapter 4 of this document.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
5 - 2 3
System Planning and Engineering
Cabling
............................................................................................................................................................................................................................................................
Overview
Lucent offers a full complement of transmission cables and optical jumpers. All interfaces to the DMX are connectorized. For synchronization interfaces, wire-wrap connections are available. Also, a special 9-pin D-SUB connector (408267722) can be used for synchronization purposes. Rear access cabling is available.
For more information
For more information regarding cable ordering, refer to Chapter 7,
“Ordering.” For more information on required cables and cable arrangements, refer to Chapter 4, “Product Description.”
...........................................................................................................................................................................................................................................................
5 - 2 4
365-372-300
Issue 8.0, September 2006
System Planning and Engineering
Environmental Considerations
............................................................................................................................................................................................................................................................
Overview
DMX meets NEBS Level 3 standards for use in central office environments as specified in GR-63-CORE and GR-1089-CORE.
DMX also meets standards for uncontrolled environments as specified in GR-63-CORE and GR-499-CORE. For detailed specifications, refer to Chapter 10, “Technical Specifications.”
Recycling / take-back / disposal of product
Electronic products bearing or referencing the symbol shown below when put on the market within the European Union, shall be collected and treated at the end of their useful life, in compliance with applicable
European Union and local legislation. They shall not be disposed of as part of unsorted municipal waste. Due to materials that may be contained in the product, such as heavy metals or batteries, the environment and human health may be negatively impacted as a result of inappropriate disposal.
Figure 5-5 Take Back Symbol
In the European Union, a solid bar under the crossed-out wheeled bin indicates that the product was put on the market after 13 August 2005.
Moreover, in compliance with legal requirements and contractual agreements, where applicable, Lucent Technologies will offer to provide for the collection and treatment of Lucent Technologies products at the end of their useful life, or products displaced by Lucent
Technologies equipment offers.
For information regarding take-back of equipment by Lucent
Technologies, or for more information regarding the requirements for recycling/disposal of product, please contact your Lucent Account
Manager or Lucent Takeback Support [email protected].
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
5 - 2 5
System Planning and Engineering
Cross-connections
Overview
............................................................................................................................................................................................................................................................
Purpose
This section provides cross-connection information for the DMX
Access Multiplexer. For cross-connect provisioning information, refer to Chapter 6, “Operations, Administration, Maintenance, and
Provisioning.”
Contents
The following cross-connect information is included in this section:
Assignment of VT Bandwidth on OC-48 and OC-12 Highspeed Interface
...........................................................................................................................................................................................................................................................
5 - 2 6
365-372-300
Issue 8.0, September 2006
System Planning and Engineering
Cross-Connect Types
............................................................................................................................................................................................................................................................
Overview
The DMX has cross-connect capabilities offering users flexibility in directing traffic flow through systems to support a wide variety of customer applications using one-way and multi-point (data specific) cross-connections.
Making cross-connections
Cross-connections are made by specifying the SONET rate (VT1.5 or
STS-n), the end point addresses (AIDs), and the cross-connection type
(for example, 1WAY). Each single cross-connection command establishes a 1-way cross-connection.
Atomic cross-connections
Beginning in R6.0, DMX employs atomic cross-connections for all cross-connect provisioning. The introduction of atomic crossconnections simplifies cross-connection provisioning and lays the ground work for the support of additional applications and combinations of cross-connections in future releases. Atomic crossconnections are one-way cross-connections between logical ring channels which can be set up and taken down by a single command, and which cannot be broken down into smaller parts. Logical ring channels are the tributaries of a port or port protection group used for transmission in the absence of any line or equipment protection.
Atomic cross-connections are more flexible than the cross-connect provisioning structure employed previously. They allow for the support of more detailed applications because multiple atomic crossconnections can be provisioned to construct the desired crossconnection application.
The difference is that you are provisioning each portion of the 2way cross-connect (as in legacy releases) as 1way cross-connects. This provides increased flexibility in provisioning all cross-connects.
For customers who use the WaveStar PC-CIT, Telcordia Operating
Systems (OS), and Navis INC this change will be transparent. In order to support atomic cross-connections for the first time, customers employing proprietary OS solutions will need to adjust their crossconnection provisioning procedures.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
5 - 2 7
Cross-Connect Types
System Planning and Engineering
Bidirectional (two-way) cross-connections
A bidirectional connection can be used to send signals between two high-speed ports (pass-through), two low-speed ports (hairpin or passthrough), and a high-speed and low-speed port (add/drop).
Bidirectional cross-connections are supported at the VT1.5, STS1,
STS3c, STS12c and STS48c rates as a function of the port types (OC-
12/48/192— high-speed). Bidirectional cross-connections can be used in hairpinning and pass-through applications as well. Beginning in
R6.0, DMX employs atomic cross-connects. Therefore, DMX no longer supports a single TL1 command to set up a two-way crossconnect; rather the user must provision two one-way cross-connects.
Unidirectional (one-way) cross-connections
A one-way cross-connection is a single-ended connection that can be used to send signals between two high-speed ports (pass-through or hairpin, hairpin with the LNW59 only), two low-speed ports (hairpin or pass-through), and a high-speed and low-speed port (add/drop). In add/ drop applications, this is used where VT1.5, STS-1, STS-3(c), STS-
12(c), STS-48(c) signals on high-speed channels are cross-connected to low-speed DS1/E1, DS3, EC-1, OC-3, OC-12, 100BASE-TX,
100BASE-LX, 1000BASE-SX/LX, or FC-DATA ports. With highspeed OC-192/48 optics, high-speed STS-48(c) signals may also be cross-connected. DMX allows one-way cross-connections in support of
DRI, bridge and roll, and true 0x1 unprotected scenarios.
Hairpinning crossconnections
In “hairpinning” topologies prior to R7.0 that employed the LNW45 and LNW49 circuit packs, tributary (low-speed) traffic was routed into the system and back out without ever being placed on the high-speed
(OC-12, OC-48 or OC-192) interfaces. If the VLF Main pack
(LNW59) available in R7.0 is used, all cross-connect and switching functions are centralized on the Main pack. Switching within the fabrics on the tributary (low-speed) OLIUs is disabled and traffic is routed directly to the STS fabric on the Mains, bypassing any VT fabric on the tributary OLIUs.
DMX is capable of connecting any input on a circuit pack in a function or growth slot to any output on a circuit pack in a different function or growth slot in the same shelf (known as inter-fn hairpin). DMX also supports intra-port hairpins, by which DMX can hairpin between different ports in the same group. R7.0 adds support for hairpin crossconnections to 0x1Sn interfaces. When R7.0 or later software is used in conjunction wit VLF Mains, hairpin cross-connections between unprotected ports on different slots of the same low-speed group are also supported.
...........................................................................................................................................................................................................................................................
5 - 2 8
365-372-300
Issue 8.0, September 2006
Cross-Connect Types
Locked DS1/DS3 Cross
Connections
System Planning and Engineering
These flexible cross-connect capabilities allow you to use a combination of add/drop and hairpinning of compatible payloads through a variety of interfaces. You can bring traffic in from one remote site and cross-connect it at the VT1.5, STS-1, STS-3c, STS-12c, or STS-48c level back out to other remote sites without consuming any capacity on the ring/line interface.
In the “locked” mode, DMX does not select the best signal from both rotations of a UPSR. Instead, traffic is added and dropped (locked) from one rotation of the ring only (provisionable). The main advantage of locked DS1/DS3 cross-connections is the lack of UPSR switching.
This feature is extremely useful in utility applications.
Locked VT Cross
Connections (R7.0)
In the “locked” mode, DMX does not select the best signal from both rotations of a UPSR. Instead, traffic is added and dropped (locked) from one rotation of the ring only (provisionable). The main advantage of locked VT cross-connections is the lack of UPSR switching which results in the ability to reuse timeslots around a UPSR.
The ability to mix locked, unlocked, and pass-through VT1.5s within the same STS-1 was added in R6.0.2.
Locked cross-connections are only used in systems that are not equipped with VLF Mains because VLF mains allow unprotected
(linear) UPSR cross-connections which allow users to independently provision cross-connections on UPSR tributaries. In systems with non-
VLF Mains, once a locked cross-connection is established from a
UPSR tributary, the companion tributary cannot be cross-connected.
Linear/Unprotected UPSR
(R7.0)
In R7.0, DMX also allows both rotations of a ring to be used simultaneously. Prior to 7.0, if a 1WAY (as opposed to a path-protected
1WAYPR) cross-connection was established with the source from a
UPSR ring, the other side became unusable as the source (1WAY) or destination of a cross-connection (1WAY or 1WAYPR), except for pass-through cross-connections. This feature removes those restrictions.
DMX permits simultaneous 1WAY cross-connections sourced from the
2 associated ring channels in a UPSR application, simultaneous 1WAY cross-connection sourced from a ring channel, and 1WAY or
1WAYPR destined to the associated ring channel.
This feature removes the need for unswitched cross-connections on
Ethernet/Data packs which don’t require VCG pairing, yet they will still be supported to ensure backwards compatibility.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
5 - 2 9
Cross-Connect Types
System Planning and Engineering
Multi-point (data-specific) cross-connections
The data specific multi-point cross-connect is a bidirectional crossconnection between two STS-1 Virtual Concatenation Groups (VCGs) on 100BASE-TX or 1000BASE-SX/LX ports to two different ring interfaces. All multi-point cross-connections are done at the STS-1 level (multi-point cross-connections can also be made at the STS-3c, and STS-12c level using the LNW63, LNW70, LNW71, LNW78 circuit pack-- the LNW71 does not support STS-12c). Multi-point cross-connections are used to create packet rings.
Beginning in R6.0, multiple 1WAY UNSWITCHED cross-connections provide unprotected SONET connections to Ethernet circuit packs.
Each can be used to form two individual connections. With atomic cross-connections, multipoint cross-connections are provisioned by way of 1WAY UNSWITCHED cross-connects.
...........................................................................................................................................................................................................................................................
5 - 3 0
365-372-300
Issue 8.0, September 2006
Cross-Connect Types
System Planning and Engineering
Bridged cross-connections
DMX supports multicast (1xN) cross-connections where N is limited only by the available cross-connect fabric (fr VTs) and the compatible output tributaries. Bridging of an existing cross-connection consists of adding a one-way cross-connection with the same input tributary as that of an existing cross-connection, resulting in a 1x2 multicast from an input tributary to two output tributaries. DMX supports bridging for each of the supported SONET cross-connection rates. You can bridge any existing cross-connection to a second output port without impairing the existing signal. Conversely, either half of a bridged signal can be taken down without impairing the remaining crossconnected signal.
Pipe-mode (adaptive-rate) cross-connections
DRI cross-connections
Pipe mode is a fault and PM feature whereby fault and PM are reported independently for each constituent signal within a cross-connection rather than simply at the xc rate.
DRI cross-connections, used in Dual Ring Interworking applications, are accomplished by means of a one-way, protected drop from a UPSR, a one-way pass-through, and a one-way add to the same UPSR.
Manual cross-connect rates
The following lists the signals that can be cross-connected:
• VT1.5
• STS-1
• STS-3c
• STS-12c
• STS-48c
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
5 - 3 1
System Planning and Engineering
Allowable Cross-Connects
............................................................................................................................................................................................................................................................
Overview
The DMX utilizes several types of SONET, DSn/Electrical, and
Ethernet cross-connections, including:
• add/drop
– Unidirectional Path Switched Ring (UPSR)
– Bidirectional Line Switched Ring (BLSR)
– Linear 1+1
– Bidirectional 1+1
– Unswitched UPSR
• unprotected optical
– 0x1Sn
(only available on shelves that do not employ LNW59 VLF
Main)
– 0x1
(only available in R7.0 and later Releases with the use of the
LNW59 VLF Main)
• hairpin
– inter-function group
– intra-function group
– intra-port
• pass-through
• multi-point (Ethernet only)
• Ethernet hairpinning
...........................................................................................................................................................................................................................................................
5 - 3 2
365-372-300
Issue 8.0, September 2006
Allowable Cross-Connects
Add/Drop
System Planning and Engineering
All connections from a high-speed interface to a low-speed interface are considered add/drop. An add/drop cross-connection is bidirectional cross-connection between a high speed interface and a low speed interface. DMX also supports unidirectional add and drop crossconnections. A signal can also be add/dropped from electrical and
Ethernet interfaces.
Unidirectional Path Switched Ring (UPSR)
A UPSR is self-healing ring configuration in which traffic is sent onto both rotations (both fibers) of the ring in opposite directions. “Pathswitched” means that if the working signal fails, the path switches to the protection signal. UPSRs operate in an integrated, single ended fashion— negating the need for complex network-level coordination in the effort to restore traffic.
Bidirectional Line Switched Ring (BLSR)
A 2-fiber is a self-healing ring configuration in which bidirectional traffic travels over the same set of nodes in each direction.
Bidirectional switching makes use of redundant (protection) bandwidth on the bidirectional lines that interconnect the nodes in the ring to provide protection for traffic carried on the working bandwidth.
Because the traffic is bidirectional, a single circuit does not necessarily consume bandwidth on every span in the ring. This leaves the spans between other nodes available for additional traffic. Therefore, with distributed switching patterns, a BLSR can carry more traffic than the same facilities could carry if configured for a unidirectional pathswitched ring.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
5 - 3 3
Allowable Cross-Connects
System Planning and Engineering
Unswitched
DMX provides an equipment-unprotected cross-connect mode, referred to as unswitched UPSR, on OC-3/12/48 low-speed ports, OC-12/48/
192 high-speed UPSRs, and OC-48/192 BLSR NUT tributaries. This option is user-provisionable on a per cross-connection basis and supports single- and dual-homed ring on ring topologies.
0x1Sn
0x1Sn is not supported when DMX is equipped with VLF Main packs
(LNW59). VLF Main packs make true 0x1 cross-connections available beginning in R7.0.
With 0x1Sn, the OC-n 0x1 provisioning and alarming capability provides the user with a method of provisioning a LS OC-n port in one slot of a slot pair to operate as an unprotected interface. Crossconnections to 0x1Sn ports are provisioned using the ring channel
AIDs corresponding to the active side/port. The inactive port, if equipped, always outputs STS1 UNEQ or AIS-P on all tributaries, as a function of the system default idle signal provisioning.
Cross-connections are supported between 0x1Sn ports and all other interface types. For DHA applications, 1WAYPR and 1WAY crossconnections between a 0x1Sn port to a UPSR ring channel are required.
Cross-connections supported at all rates supported by the LS OC-n port. Multipoint and unswitched cross-connections to 0x1Sn interfaces are not supported.
The figure below shows high-level schematics of two-way add/drop, unswitched, and 0x1Sn cross-connections.
...........................................................................................................................................................................................................................................................
5 - 3 4
365-372-300
Issue 8.0, September 2006
Allowable Cross-Connects
System Planning and Engineering
Figure 5-6 Two-way add/drop, Unswitched, and 0x1Sn
OC-N
MAIN Fabric
A1+2-
G1+2
OC-n
1+1 or UPSR
(a) OC-n Two-way drop
MAIN1 Interface MAIN2 Interface
OC-N
DS1,DS3, EC1
(b) Two-way drop terminated or drop non-terminated path
MAIN1 Interface
OC-N
Function or
Growth Slot
Interface
(A1...G1)
OC-N
OC-N
Function or
Growth Slot
Interface
(A2...G2)
OC-N
Function or
Growth Slot
Interface
(A1...G1)
(c) 0x1Sn
NC-DMX-154
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
5 - 3 5
Allowable Cross-Connects
System Planning and Engineering
True 0x1 (R7.0)
With the introduction of the VLF Main pack (LNW59) in R7.0, DMX allows true 0x1 unprotected circuit packs. That means that any slot can be equipped with any pack (some restrictions apply). Two of the same circuit packs can also populate adjacent slots in the same group (this includes some Ethernet packs). For detailed information on circuit pack/slot equipage restrictions in 0x1 mode, refer to
.
In the case of OLIUs (SONET optical line interface packs), all ports in a pack must be set to 0x1 application in order for a different pack to be used in the companion slot. If any pair of lines is provisioned for a protected application (1+1, UPSR, BLSR), then both packs in the group must be of the same type.
True 0x1 replaces 0x1Sn functionality when VLF Mains are used. True
0x1 supports all the capabilities 0x1Sn allow, but adds the capability for both slots of a single group to function independently. 0x1Sn will still be supported when the shelf is equipped with non-VLF Mains.
True 0x1 is only available on the low-speed/tributary packs, not on the
Main (M1/M2) interfaces.
When two circuit packs in the same low-speed group are operating in
0x1 mode, all provisioning, reporting and retrieval (of alarms) associated with the pack, ports and tributaries in Slot 1 are independent of the provisioning, reporting and retrieval associated with the pack, ports and tributaries in Slot 2.
When provisioned for 0x1 operation, the affect on service and severity of alarms issued against a pack in Slot 1 of a particular group are independent from the affect on service and the severity of the alarms issued against the pack in Slot 2 of that group.
When DMX is equipped with VLF Mains, all 1-way cross-connections presently supported on an unprotected port/line (including ports/lines on an unprotected pack) in one slot of an LS group can be supported independently and simultaneously on an unprotected port/line in either slot of a Function or Growth group. 1-waypr cross-connections are not allowed to be sourced from 0x1 interfaces.
True 0x1 enables hairpin cross-connections between channels on packs in different slots of the same Function or Growth group.
...........................................................................................................................................................................................................................................................
5 - 3 6
365-372-300
Issue 8.0, September 2006
Allowable Cross-Connects
System Planning and Engineering
Pass-through
A pass-through cross-connection is made between two ring interfaces in the same MAIN or Function Unit group, allowing the signal to be
“passed-through” a ring node on the same timeslot.
The figure below shows a pass-through cross-connection on the highspeed interface (OC-12, OC-48, or OC-192).
Figure 5-7 Pass-through cross-connection on High-speed interface
Main TDM Fabric
OC-N OC-N
Two-way pass-through path nc-dmx-160
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
5 - 3 7
Allowable Cross-Connects
System Planning and Engineering
Low-speed pass-throughs
The DMX can host multiple rings on the low-speed interfaces of the
DMX shelf. This is accomplished by intra-function group, passthrough cross-connections. The DMX can close a low-speed ring by supporting a cross-connection between a receive port on one circuit pack and a transmit port on another circuit pack in the same function or growth group. All protection switching advantages/capabilities still apply in VT and STS-n Ring Closure applications. When VLF Main packs are used, all cross-connect switching occurs on the main packs, including low-speed, tributary pass-through cross-connects. This means that the line depicting the pass-through cross-connect in the figure below would have to extend out of the tributary packs, up into the MAIN switch fabric at the top of the figure when VLF Mains are used.
Figure 5-8 Pass-through hairpin
MAIN TDM Fabric M1 + 2
A-G A-G
Ring Pass - Through
(VT - Ring Closure) nc-dmx-159
...........................................................................................................................................................................................................................................................
5 - 3 8
365-372-300
Issue 8.0, September 2006
Allowable Cross-Connects
System Planning and Engineering
SONET hairpinning Crossconnections
In “hairpinning” topologies prior to R7.0 that employed the LNW45 and LNW49 circuit packs, tributary (low-speed) traffic was routed into the system and back out without ever being placed on the high-speed
(OC-12, OC-48 or OC-192) interfaces. If the VLF Main pack
(LNW59) available in R7.0 is used, all cross-connect and switching functions are centralized on the Main pack. Switching within the fabrics on the tributary (low-speed) OLIUs is disabled and traffic is routed directly to the STS fabric on the Mains, bypassing any VT fabric on the tributary OLIUs.
DMX is capable of connecting any input on a circuit pack in a function or growth slot to any output on a circuit pack in a different function or growth slot in the same shelf (known as inter-fn hairpin). DMX also supports intra-port hairpins, by which DMX can hairpin between different ports in the same group. R7.0 adds support for hairpin crossconnections to 0x1Sn interfaces. When R7.0 or later software is used in conjunction wit VLF Mains, hairpin cross-connections between unprotected ports on different slots of the same low-speed group are
also supported (certain restrictions apply, refer to
).
These flexible cross-connect capabilities allow you to use a combination of add/drop and hairpinning of compatible payloads through a variety of interfaces.
DMX supports intra-function group, hairpin cross-connections that are cross-connections between different tributaries on different ports within the same function group. Intra-port hairpins are crossconnections between channels hosted by the same physical port of the
DMX shelf. These intra-port hairpins are only supported on 1+1 protected interfaces.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
5 - 3 9
Allowable Cross-Connects
System Planning and Engineering
The figure below shows some of the various SONET hairpinning schemes.
Figure 5-9 SONET hairpinning
MAIN TDM Fabric M1 + 2 MAIN TDM Fabric M1 + 2
A-G
(a) 1+1 Hairpin
MAIN TDM Fabric M1 + 2
A-G A-G
OC-3/OC-12/
OC-48
UPSR
OC-3/OC-12/
OC-48
UPSR
(b) 2 Closed UPSR, Hairpin
A-G
MAIN TDM Fabric M1 + 2
A-G
OC-3/OC-12/
OC-48
UPSR
(c) UPSR
1+1
1+1 Hairpin
A-G
A-G
A-G
1+1 or UPSR
(d) 1+1 or UPSR
DS1,DS3,EC1
DS1, DS3, EC1, Hairpin
NC-DMX-151
...........................................................................................................................................................................................................................................................
5 - 4 0
365-372-300
Issue 8.0, September 2006
Allowable Cross-Connects
System Planning and Engineering
Portless mode hairpin cross-connections
(LNW20)
The figure below depicts hairpin cross-connects involving the LNW20 in portless mode. When operating in portless mode, LNW20 pulls
DS1s from channelized DS3 signals that enter DMX on a SONET STS-
1 interface (on another pack) and converts them to VT mapped STS-1s.
This VT-mapped STS-1 is cross-connected at the VT level in the Main packs (at least one side of the cross-connect is OCn/EC1) to any interface that supports the signal structure today (DS1, channelized
DS3, EC1, optical).
For portless functionality, incoming STS-1s must contain a channelized
DS3. This STS-1 is cross-connected to the LNW20 and then hairpinned to the STS fabric on the Main pack. Once the signal is finally converted to a VT1.5 it can be cross-connected to any port that accepts that signal format.
Figure 5-10 LNW20 portless mode cross-connects
monitor DS1/DS3 egress fault/PM
Main
STS fabric
STS1->
DS3->
DS1->
VT->
STS1
STS1->
VT->
DS1->
DS3->
STS1
LNW20 in group a
STS1->
VT->
DS1
VT fabric
STS1 containing channelized DS3 monitor DS1 fault/
PM monitor
STS fault/
PM
SONET/SDH fn/main
DS1 DSX
DS1 card in group b
Important!
In the figure above, the LNW20 is depicted in function group “a” as an example, not a requirement. The different colored solid lines also represent independant cross-connects.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
5 - 4 1
Allowable Cross-Connects
System Planning and Engineering
Multi-point (Ethernet only)
The data-specific multi-point cross-connect is a bidirectional crossconnection between two STS-1 Virtual Concatenation Group (VCG) on 100BASE-TX/LX or 1000BASE-SX/LX and ports to two different ring interfaces (UPSR or BLSR with NUT provisioning).
The figure below shows Ethernet Multipoint cross-connection schematic.
Figure 5-11 Ethernet Multi-point cross-connection
OC-48/OC-192 OC-48/OC-192
M1 M2
Lan Switch
Empty
Slot
A1-G1
100 BASE-TX
1000 BASE-SX/LX
Multipoint Ethernet
A2-G2
NC-DMX-152
...........................................................................................................................................................................................................................................................
5 - 4 2
365-372-300
Issue 8.0, September 2006
Allowable Cross-Connects
System Planning and Engineering
Ethernet hairpining Crossconnections
With Ethernet-to-Ethernet hairpinning, traffic may travel from one
Ethernet port on a circuit pack in one set of slots, to another port on a circuit pack in a different set of slots (from A1 to C1 or A2 to C2, for example). From there, the traffic may be multiplexed with other packet traffic before being switched onto another Ethernet or SONET interface.
In shelves equipped with R7.0 software and VLF Mains (LNW59), hairpins between 0x1 compatible Ethernet packs located in Slot 1 and
Slot 2 of the same group are also supported. For detailed information regarding 0x1 circuit pack compatibility, refer to
The figure below shows some of the high-level schematics of Ethernet hairpinning cross connections.
Figure 5-12 Ethernet hairpinning
MAIN TDM Fabric M1+2 MAIN TDM Fabric M1+2
A1+A2-
G1+G2
UPSR or
1+1
(a) 1+1 or UPSR
Lan Switch
A1+G1
100 BASE-TX/FX
1000 BASE-SX/LX
Ethernet Hairpin
MAIN TDM Fabric M1+2
A1+A2-
G1+G2
Lan Switch
A1-G1
OC-n
0X1 or UPSR
(b) OC-N 0X1 or UPSR
100 BASE-TX/FX
1000 BASE-SX/LX
Multi-Point Ethernet Hairp
Lan Switch
A1-G1
Lan Switch
A1-G1
100 BASE-TX/FX
1000 BASE-SX/LX
100 BASE-TX/FX
1000 BASE-SX/LX
(c) Ethernet - Ethernet Hairpin
Important!
Ethernet hairpinns to BLSR interfaces are also supported.
NC-DMX-1
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
5 - 4 3
Allowable Cross-Connects
System Planning and Engineering
Multi-point Ethernet
Combinations
Multi-point Ethernet cross-connections are supported from Ethernet ports, to ports provisioned for UPSR or BLSR with NUT only. In much the fashion as shown in the figure below, the DMX supports Multipoint Ethernet cross-connections between the following combinations of interfaces:
• OC-12/48/192 MAIN OLIUs & one 100-TX/LX or 1000-SX/LX/
ZX (A-G)
• OC-3/12/48 OLIU (A-G) & one 100-TX/LX or 1000-SX/LX/ZX interface (A-G)
Figure 5-13 Multi-point Combinations
MAIN TDM Fabric
M1+2
LAN Switch LAN Switch LAN Switch OC-3/12/48
OC-3/12/48
100BASE-TX/LX
1000 BASE-SX/LX
Multipoint GbE
Combinations nc-dmx-161
...........................................................................................................................................................................................................................................................
5 - 4 4
365-372-300
Issue 8.0, September 2006
Allowable Cross-Connects
System Planning and Engineering
Ethernet Circuit Pack
Capacities Summary
The table below details various characteristics of the Ethernet and FC-
DATA (SAN) circuit packs. The table covers the rate, transport format
(PL or Switched), differential delay, frame size, LCAS capability,
Release number, OSP capability as well as the number, format and capacity of VCGs supported by each Ethernet circuit pack in the DMX.
Table 5-3 Ethernet Circuit Pack Capacities Summary Part 1
Pack Rate
(port #)
LNW63
1G SX/LX/
ZX PL
LNW64
1G SX/LX/
ZX PL
LNW66
10/100 T
LNW67
1G SX
LNW68
1G LX
LNW70
100/1G FS
1000BASE-SX/LX/
ZX (4)
1000BASE-SX/LX/
ZX (8)
100BASE-TX
(24)
1000BASE-SX (2)
1000BASE-LX (2)
100BASE-LX
(4- PTM)
1000BASE-X
(4-PTM)
LNW78
100/1G
RPR
LNW78
100/1G
EoS
LNW71
10/100 PL
100BASE-LX
(4- PTM)
1000BASE-X
(4-PTM)
100BASE-TX
(24)
PL or
Switched
VCG
Ports
PL 4
VT1.5xv
-
VCG Format and Capacity (Max # of tributaries per VCG
1
STS-1 STS-1xv
21 21
STS-3c STS-3cxv
STS-12c
7 7 1
PL
Switched
PL /
Switched
PL /
Switched
PL /
Switched
Switched
PL
8
2
2-4
3
2-4
3
32
2
6
16
2
-
-
-
-
-
-
21
-
-
-
X
24
X
21
21
21
21
48
-
-
7
-
-
-
X
8
X
7
-
-
-
16
-
-
1
1
(only on
VCGs
1-28)
-
-
-
-
X
24
2
2 -
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
5 - 4 5
Allowable Cross-Connects
System Planning and Engineering
Pack Rate
(port #)
LNW73/73c
FC-DATA
(SAN)
FC-1G/FICON (4)
OR
ESCON (4)
PL or
Switched
PL
PL
VCG
Ports
4
VT1.5xv
-
VCG Format and Capacity (Max # of tributaries per VCG
1
STS-1 STS-1xv
48
(FC-
FICON)
6
(ESCON)
-
STS-3c STS-3cxv
STS-12c
16
(FC-
FICON)
2
(ESCON)
1
(FC-
FICON)
24 63 X 3 X LNW74
10/100 T/F
100BASE-TX
(16)
100BASE-LX
(8-PTM)
Pack
LNW63 GbE PL A-G
LNW64 GbE PL A-G
Table 5-4 Ethernet Circuit Pack Capacities Summary Part 2
Slots where Differential packs can reside
Delay (ms)
LCAS
Support
50
108
16
16
Y
Y
-
-
Maximum
Frame Size
10240
10240
1536
1536
OSP
Y
Y
(optical PTM/
SFPs only)
-
-
Release
6.0
7.0
1.1
1.1
LNW66 10/100 T A-D
LNW67
1G SX
A-G
A-G LNW68
1G LX
LNW70
100/1G FS
LNW78
RPR/EoS
LNW71
10/100 PL
A-G
A-G
A-D
16
50
50
32
-
Y
-
-
1536
10240
10240
10240 -
-
-
1.1
5.1
6.0
3.1
...........................................................................................................................................................................................................................................................
5 - 4 6
365-372-300
Issue 8.0, September 2006
Allowable Cross-Connects
Pack Slots where Differential packs can reside
Delay (ms)
LCAS
Support
A-G 120 Y
6
LNW73/73C
FC-DATA
(SAN)
LNW74
10/100 T/F
A-G
5
65 Y
Maximum
Frame Size
System Planning and Engineering
OSP Release
2160
5
9632
-
Y
5.1
5.0
NOTES
1.For every pack other than the LNW64, maximum 2.5G (48 STS-1) between any function slot and the backplane - double (5G) with multipoint cross connections for
DMX. LNW64 has a maximu backplane capacity of 10G (192 STS-1s).
2. 24 ports when set to STS-1 mode – 16 when set to STS-3c mode
3. 2 with 2waypr cross-connections; 2 with mltpt cross-connections; the LNW67 and
LNW68 have 4 VCGs, only two of which are addressable for xc provisioning. The other two are automatically connected when the xc is provisioned. This is no longer the case with Atomic cross-connects (R6.0). With atomic cross-connects, unswitched (the atomic equivalent of multipoint) cross-connects are provisioned seperately for odd/even number VCG pairs.
4. Maximum frame size for async-FC provisioned ports is 2160.
5. When the LNW74 is used in slot G1, only the optical ports are functional.
6. The LNW73 and LNW73C do support LCAS, but only for asyncFC traffic.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
5 - 4 7
Allowable Cross-Connects
System Planning and Engineering
Ethernet Circuit Pack
Capacities for Ring
Configurations
The table below details the allowable Ethernet-related ring configurations (Ethernet applications within UPSR and BLSR topologies) and the number of these configurations that may be supported by each Ethernet circuit pack in the DMX.
Important!
Capacities for each configuration are available in the later of the release numbers shown at the left of the row and the top of the column.
For more information on Packet Rings, Ethernet Private Lines, and Ethernet Rate Shaping, refer to the corresponding section in
Chapter 3 of this document.
Table 5-5 Ethernet Circuit Pack Capacities for Ring
Configuration
Configurations
Release
1.1
LNW63/
LNW64
1000
Mbps
(GbE-PL)
(4-port/8port)
LNW66
10/100
Mbps
(FE-BPR)
R6/7.0
2/4
R1.1
1
LNW67/
68
1000
Mbps
(GbE-
BPR)
Port Units
LNW71 LNW74
3
10/100
Mbps
(FE-EPL)/
1000
Mbps
(GbE-PL)
10/100
Mbps
(FE-EPL)
R1.1
2
R3.1
0
R5.0
0
LNW70 LNW78
10/100/
1000
Mbps
(FE/GbE-
BPR)
R5.1
16
10/100/
1000
Mbps
(FE/GbE-
RPR/
EoS)
R6.0
1 Packet Rings on
UPSRs
Packet Rings on
BLSRs
1
Packet Rings on
BLSRs w/ NUT
PL on UPSR w/
UPSR protection
PL on UPSR w/
out UPSR protection
PL on BLSR
EPL on BLSR w/ NUT
2.1
3.0
1.1
1.1
2.1
3.0
2/4
2/4
2/4
2/4
2/4
2/4
0
1
1
2
1
2
1
2
2
2
2
2
0
0
16-24
16-24
16-24
16-24
2
2
2
2
0
0
16-24
NA
16-24
16-24
16
16
16-32
16-32
16-32
16-32
-
1
6
6
6
6
...........................................................................................................................................................................................................................................................
5 - 4 8
365-372-300
Issue 8.0, September 2006
Allowable Cross-Connects
System Planning and Engineering
Configurations
Release
LNW63/
LNW64
1000
Mbps
(GbE-PL)
(4-port/8port)
LNW66
10/100
Mbps
(FE-BPR)
LNW67/
68
1000
Mbps
(GbE-
BPR)
R1.1
Port Units
LNW71 LNW74
3
10/100
Mbps
(FE-EPL)/
1000
Mbps
(GbE-PL)
R3.1
10/100
Mbps
(FE-EPL)
R5.0
R6/7.0
BPR= Basic Packet Ring
RPR= Resilient Packet Ring
EPR= Enhanced Packet Ring (w/ rate shaping
EPL= Ethernet Private Line (point-to-point)
PL= Private Line (point-to-point)
FE= Fast Ethernet (10/100 Mbps)
GbE= Gigabit Ethernet (1000 Mbps)
FC-DATA= SAN card (FICON/ESCON/FC)
R1.1
LNW70 LNW78
10/100/
1000
Mbps
(FE/GbE-
BPR)
R5.1
10/100/
1000
Mbps
(FE/GbE-
RPR/
EoS)
R6.0
NOTES
1.Each span of the packet ring has BLSR protection. It is not necessary to “close” the packet ring on a BLSR: BLSR protection is provided on each span, so spanning tree protection is unnecessary. Capacity on one span of the BLSR can be used for other purposes.
2. For LNW71: 16 ports for STS-3c mode, 24 ports otherwise.
3.The number of EPL cross-connections on the LNW74 is relative to the slot in which the circuit pack is housed and not the cross-connection rate. 24 VCGs are provisionable in slots A-D. 8 VCGs are provisionable in slot G.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
5 - 4 9
Allowable Cross-Connects
System Planning and Engineering
All Allowable UPSR Adddrop Cross-connections
The table below contains a list of UPSR add-drop cross-connections supported by
DMX
in Release 7.0. The cross-connections in the table below are all drop cross-connections
.
Important!
R6.0 and later releases employ atomic crossconnections. With atomic cross-connects, all cross-connections are oneway. For cross-connects not involving UPSR interfaces, the same 1-way cross-connects are supported in the opposite direction to provide twoway connectivity.
R7.0 also introduces the LNW59 VLF Main which makes true 0x1 cross-connections and shelf equipage possible. When the LNW59 is used, the shelf doesn’t support 0x1Sn cross-connections (only 0x1) or the LNW6 and LNW7. In shelves equipped with VLF Mains, unprotected (linear) UPSR cross-connections are also supported.
Unprotected UPSR cross-connections are independent crossconnections to/from the companion UPSR tributaries. For these reasons, the capabilities of the shelf when equipped with the LNW59 are listed separately.
In the “To” column of the table below, “TransMUX” includes the
LNW18 and LNW20 in both ported and portless mode.
Table 5-6 All Allowable UPSR Add-drop Cross-connections
...........................................................................................................................................................................................................................................................
5 - 5 0
365-372-300
Issue 8.0, September 2006
Allowable Cross-Connects
System Planning and Engineering
From
VLF Main OC-192 (LNW59) OLIU
(UPSR)
1-way STS-n --------------------->
1-way VT1.5-------->
1-way unswitched STS-n-------->
1-way unswitched VT1.5-------->
1-waypr STS-n ------------------->
1-waypr VT1.5 -------------------->
To
NOTE: LNW59 has more than one OC-192 port, making cross-connections between different OC-192 ports on the same Main are possible when it is used. All of the cross-connect types listed in the left column are supported between LNW59 ports.
DS1, E1, DS3, EC-1, TransMUX, OC-3/12/48
(1+1, UPSR, 0x1), OC-48 (BLSR), 100-TX/LX,
1000-SX/LX/ZX, FC-DATA
DS1, EC-1, TransMUX, OC-3/12/48 (1+1, UPSR,
0x1), 100-TX/LX (LNW74 only)
OC-3/12/48 (UPSR), OC-48 BLSR w/ NUT, 100-
TX/LX, 1000-SX/LX/ZX (no LNW74)
OC-48/192 (UPSR, BLSR w/ NUT)
DS1, E1, DS3, EC-1, TransMUX, OC-3/12/48
(1+1, UPSR, 0x1), OC-48 (BLSR), 100-TX/LX,
1000-SX/LX/ZX, FC-DATA
DS1, EC-1, TransMUX, OC-3/12/48 (1+1, UPSR,
0x1), 100-TX/LX (LNW74 only)
Non-VLF OC-192 OLIU (UPSR)
1-way STS-n --------------------->
1-way VT1.5-------->
1-way unswitched STS-n-------->
1-way unswitched VT1.5-------->
1-waypr STS-n ------------------->
1-waypr VT1.5 -------------------->
DS1, E1, DS3, TransMUX, OC-3/12/48 (0x1Sn),
100-FX/1000 SX/LX/ZX (LNW78 only)
DS1, EC-1, TransMUX, OC-3/12/48 (0x1Sn)
OC-3/12/48 (UPSR), OC-48 BLSR w/ NUT,
1000-SX/LX/ZX, 100-TX/LX
OC-3/12/48 (UPSR), OC-48 BLSR w/ NUT
DS1, E1, DS3, EC-1, TransMUX, OC-3/12/48
(1+1, 0x1Sn, UPSR), OC-48 BLSR, 1000-SX/LX/
ZX, 100-TX/LX, FC-DATA
DS1, EC-1, TransMUX, OC-3/12/48 (0x1Sn, 1+1 and UPSR), 100-TX/LX (LNW74 only)
OC-48 High-Speed OLIU (UPSR)
1-way STS-n --------------------->
1-way VT1.5-------->
DS1, E1, DS3, TransMUX, OC-3/12/48 (0x1Sn)
DS1, EC-1, TransMUX, OC-3/12/48 (0x1Sn)
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
5 - 5 1
Allowable Cross-Connects
From
1-way unswitched STS-n-------->
1-way unswitched VT1.5-------->
1-waypr STS-n ------------------->
1-waypr VT1.5 -------------------->
OC-12 High-Speed OLIU (UPSR)
1-way STS-n --------------------->
1-way VT1.5-------->
1-way unswitched STS-n-------->
1-way unswitched VT1.5-------->
1-waypr STS-n ------------------->
1-waypr VT1.5 -------------------->
System Planning and Engineering
To
OC-3/12/48 (UPSR), OC-48 BLSR w/ NUT,
1000-SX/LX, 100-TX
OC-3/12/48 (UPSR) and OC-48 BLSR w/ NUT
DS1, E1, DS3, EC-1, TransMUX, OC-3/12/48
(1+1, 0x1Sn, UPSR), OC-48 BLSR, 1000-SX/LX,
100-TX/LX, FC-DATA
DS1, EC-1, TransMUX, OC-3/12/48 (0x1Sn, 1+1 and UPSR), and OC-48 BLSR, 100-TX/LX
(LNW74 only)
DS1, E1, DS3, TransMUX, OC-3/12/48 (0x1Sn)
DS1, EC-1, TransMUX, OC-3/12/48 (0x1Sn)
OC-3/12/48 (UPSR), OC-48 BLSR w/ NUT,
1000-SX/LX, 100-TX
OC-3/12/48 (UPSR) and OC-48 BLSR w/ NUT
DS1, E1, DS3, EC-1, TransMUX, OC-3/12/48
(1+1, 0x1Sn, UPSR), OC-48 BLSR, 1000-SX/LX,
100-TX/LX, FC-DATA
DS1, EC-1, TransMUX, OC-3/12/48 (0x1Sn, 1+1 and UPSR), and OC-48 BLSR, 100-TX/LX
(LNW74 only)
...........................................................................................................................................................................................................................................................
5 - 5 2
365-372-300
Issue 8.0, September 2006
Allowable Cross-Connects
System Planning and Engineering
All Allowable 1+1 Add-drop
Cross-connections
The table below contains a list of linear/bidirectional (1+1) add-drop cross-connections supported by DMX in Release 7.0. The crossconnections in the table below are all drop cross-connections.
Important!
R6.0 and later Releases employ atomic crossconnections. With atomic cross-connects, all cross-connections are one-way. For cross-connects not involving UPSR interfaces, the same 1-way cross-connects are supported in the opposite direction to provide two-way connectivity.
Table 5-7 All Allowable 1+1 Add-drop Cross-connections
From
VLF Main OC-192 (LNW59) OLIU
(1+1)
1-way STS-n --------------------->
1-way VT1.5-------->
To
NOTE: LNW59 has more than one OC-192 port, making cross-connections between different OC-192 ports on the same Main are possible when it is used. All of the cross-connect types listed in the left column are supported between LNW59 ports.
DS1, E1, DS3, EC-1, TransMUX, OC-3/12/48
(1+1, UPSR, 0x1), OC-48 (BLSR), 100-TX/LX,
1000-SX/LX/ZX, FC-DATA
DS1, EC-1, TransMUX, OC-3/12/48 (1+1, UPSR,
0x1), OC-48 BLSR, 100-TX/LX (LNW74 only)
Non-VLF Main OC-192 OLIU (1+1)
1-way STS-n --------------------->
1-way VT1.5-------->
DS1, E1, DS3, EC-1, TransMUX, OC-3/12/48
(1+1, 0x1Sn, UPSR), OC-48 BLSR, 1000-SX/LX/
ZX, 100-TX/LX, FC-DATA
DS1, EC-1, TransMUX, OC-3/12/48 (1+1, 0x1Sn,
UPSR), OC-48 BLSR, 100-TX/LX (LNW74 only)
OC-48 High-Speed OLIU (1+1)
1-way STS-n --------------------->
1-way VT1.5-------->
DS1, E1, DS3, EC-1, TransMUX, OC-3/12/48
(1+1, 0x1Sn, UPSR), OC-48 BLSR, 1000-SX/LX,
100-TX/LX, FC-DATA
DS1, TransMUX, OC-3/12/48 (1+1, 0x1Sn,
UPSR), OC-48 BLSR, and 100-TX/LX
OC-12 High-Speed OLIU (1+1)
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
5 - 5 3
Allowable Cross-Connects
From
1-way STS-n --------------------->
1-way VT1.5-------->
System Planning and Engineering
To
DS1, E1, DS3, EC-1, TransMUX, OC-3/12/48
(1+1, 0x1Sn, UPSR), OC-48 BLSR, 1000-SX/LX,
100-TX/LX, FC-DATA
DS1, TransMUX, OC-3/12/48 (1+1, 0x1Sn,
UPSR), OC-48 BLSR, 100-TX/LX
...........................................................................................................................................................................................................................................................
5 - 5 4
365-372-300
Issue 8.0, September 2006
Allowable Cross-Connects
System Planning and Engineering
All Allowable BLSR Adddrop Cross-connections
The table below contains a list of BLSR add-drop cross-connections supported by DMX in Release 7.0. The cross-connections in the table below are all BLSR drop cross-connections.
Important!
R6.0 and later Releases employ atomic crossconnections. With atomic cross-connects, all cross-connections are one-way. For cross-connects not involving BLSR interfaces, the same 1-way cross-connects are supported in the opposite direction to provide two-way connectivity.
Table 5-8 All Allowable BLSR Add-drop Cross-connections
From
VLF Main OC-192 (LNW59) OLIU
(BLSR)
1-way STS-n --------------------->
1-way VT1.5-------->
1-way unswitched STS-n-------->
To
NOTE: LNW59 has more than one OC-192 port, making cross-connections between different OC-192 ports on the same Main are possible when it is used. All of the cross-connect types listed in the left column are supported between LNW59 ports.
DS1, E1, DS3, EC-1, TransMUX, OC-3/12/48
(1+1, UPSR, 0x1), OC-48 (BLSR), 100-TX/LX,
1000-SX/LX/ZX, FC-DATA
DS1, EC-1, TransMUX, OC-3/12/48 (1+1, UPSR,
0x1), 100-TX/LX (LNW74 only)
OC-3/12/48 (UPSR), 100-TX/LX, 1000-SX/LX/
ZX
OC-3/12/48 (UPSR) 1-way unswitched VT1.5-------->
Non-VLF OC-192 High-Speed OLIU
(BLSR)
1-way STS-n --------------------->
1-way VT1.5-------->
1-way unswitched STS-n-------->
1-way unswitched VT1.5-------->
OC-48 High-Speed OLIU (BLSR)
DS1, E1, DS3, EC-1, TransMUX, OC-3/12/48
(1+1, UPSR, 0x1Sn), OC-48 (BLSR), 100-TX/
LX, 1000-SX/LX/ZX, FC-DATA
DS1, EC-1, TransMUX, OC-3/12/48 (1+1, UPSR,
0x1Sn), 100-TX/LX (LNW74 only)
OC-3/12/48 (UPSR), 100-TX/LX, 1000-SX/LX/
ZX
OC-3/12/48 (UPSR)
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
5 - 5 5
Allowable Cross-Connects
System Planning and Engineering
From
1-way STS-n --------------------->
1-way VT1.5-------->
1-way unswitched STS-n-------->
1-way unswitched VT1.5-------->
To
DS1, E1, DS3, EC-1, TransMUX, OC-3/12/48
(1+1, 0x1Sn, UPSR), OC-48 BLSR, 1000-SX/LX,
100-TX/LX, FC-DATA
DS1, EC-1, TransMUX, OC-3/12/48 (1+1, 0x1Sn,
UPSR), OC-48 BLSR, 100-TX/LX
OC-3/12/48 (UPSR), 1000-SX/LX, 100-TX
OC-3/12/48 (UPSR)
All allowable UPSR and
BLSR Pass-through Crossconnections (high-speed interface)
DMX supports direct pass-through cross-connections from a particular timeslot on one side of a UPSR to/from the same timeslot on the other side of the ring. BLSR pass-through cross-connections function in the same manner. Pass-through cross-connections are available at the same rates as add/drop cross-connections.
...........................................................................................................................................................................................................................................................
5 - 5 6
365-372-300
Issue 8.0, September 2006
Allowable Cross-Connects
System Planning and Engineering
All Allowable Hairpin
Cross-connections
The table below contains a list of hairpin cross-connections supported by DMX in Release 7.0. The cross-connections in the table below are all Hairpin cross-connections.
Table 5-9 All Allowable Hairpin Cross-connections
From
OC-3/12 (1+1)
1-way STS-n --------------------->
To
1-way VT1.5-------->
DS1, E1, DS3, EC-1, TransMUX, OC-3/12/48
(1+1, UPSR, 0x1, 0x1Sn), OC-48 BLSR, 1000-
SX/LX/ZX, 100-TX/LX, FC-DATA
DS1, EC-1, TransMUX, OC-3/12/48 (1+1 and
UPSR), 100-TX/LX (LNW74 only)
OC-3/12 (UPSR)
1-way STS-n --------------------->
1-way VT1.5-------->
1-way unswitched STS-n-------->
1-way unswitched VT1.5-------->
1-waypr STS-n ------------------->
1-waypr VT1.5 -------------------->
DS1, E1, DS3, EC-1, TransMUX, OC-3/12/48
(UPSR), 1000-SX/LX/ZX, 100-TX/LX, FC-
DATA
DS1, EC-1, TransMUX, OC-3/12/48 (UPSR,
0x1Sn), 100-TX/LX (LNW74 only)
OC-3/12/48 (UPSR), 1000-SX/LX/ZX, 100-LX/
TX (no LNW74)
OC-3/12/48 (UPSR)
DS1, E1, DS3, EC-1, TransMUX, OC-3/12/48
(1+1, UPSR, 0x1, 0x1Sn), OC-48 BLSR, 1000-
SX/LX/ZX, 100-TX/LX, FC-DATA
DS1, EC-1, TransMUX, OC-3/12/48 (1+1, UPSR,
0x1, 0x1Sn), OC-48 BLSR, 100-TX/LX (LNW74 only)
OC-3/12 (0x1) (requires LNW59 VLF
Main)
1-way STS-n --------------------->
1-way VT1.5-------->
DS1, E1, DS3, EC-1, TransMUX, OC-3/12/48
(UPSR, 1+1, 0x1) and OC-48 BLSR, 1000-SX/
LX/ZX, 100-TX/LX, FC-DATA
DS1, EC-1, TransMUX, OC-3/12/48 (1+1, UPSR,
0x1), 100-TX/LX (LNW74 only)
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
5 - 5 7
Allowable Cross-Connects
System Planning and Engineering
From
OC-3/12 (0x1Sn) (non-VLF Mains only)
1-way STS-n --------------------->
To
1-way VT1.5-------->
DS1, E1, DS3, EC-1, TransMUX, OC-3/12/48
(UPSR, 1+1, 0x1Sn) and OC-48 BLSR, 1000-SX/
LX/ZX, 100-TX/LX, FC-DATA
DS1, EC-1, TransMUX, OC-3/12/48 (1+1, UPSR,
0x1Sn), 100-TX/LX (LNW74 only)
OC-48 Low-Speed OLIU (1+1)
1-way STS-n --------------------->
1-way VT1.5-------->
DS1, E1, DS3, EC-1, TransMUX, OC-3/12/48
(1+1, UPSR, 0x1Sn, and 0x1), OC-48 BLSR,
1000-SX/LX/ZX, 100-TX/LX, FC-DATA
DS1, DS3, EC-1, TransMUX, OC-3/12 (1+1,
UPSR, 0x1Sn, and 0x1), OC-48 (1+1 and UPSR),
100-TX/LX (LNW74 only)
OC-48 Low-Speed OLIU (UPSR)
1-way STS-n --------------------->
1-way VT1.5-------->
1-way unswitched STS-n-------->
1-way unswitched VT1.5-------->
1-waypr STS-n ------------------->
1-waypr VT1.5 -------------------->
DS1, E1, DS3, EC-1, TransMUX, OC-3/12 (1+1,
UPSR, 0x1Sn, 0x1), OC-48 (BLSR and UPSR)
1000-SX/LX/ZX, 100-TX/LX, FC-DATA
DS1, EC-1, TransMUX, OC-3/12 (1+1, 0x1Sn,
0x1, UPSR) OC-48 UPSR) 100-TX/LX (LNW74 only)
OC-3/12/48 (UPSR), OC-48 BLSR, 1000-SX/LX/
ZX, 100-LX/TX
OC-3/12/48 (UPSR) and OC-48 BLSR w/ NUT
DS1, E1, DS3, EC-1, TransMUX, OC-3/12 (1+1,
0x1Sn, 0x1, and UPSR), OC-48 (UPSR and
BLSR), 1000-SX/LX/ZX, 100-TX/LX, FC-DATA
DS1, EC-1, TransMUX, OC-3/12 (1+1, 0x1Sn,
0x1, and UPSR), OC-48 (UPSR), 100-TX/LX
(LNW74 only)
OC-48 Low-Speed OLIU (BLSR)
1-way STS-n ---------------------> DS1, E1, DS3, EC-1, TransMUX, OC-3/12 (1+1,
UPSR, 0x1, and 0x1Sn), OC-48 (BLSR), 1000-
SX/LX/ZX, 100-TX/LX, FC-DATA
...........................................................................................................................................................................................................................................................
5 - 5 8
365-372-300
Issue 8.0, September 2006
Allowable Cross-Connects
System Planning and Engineering
From
1-way VT1.5-------->
1-way unswitched STS-n-------->
1-way unswitched VT1.5-------->
OC-48 Low-Speed OLIU (0x1)
(requires LNW59 VLF Main)
1-way STS-n --------------------->
To
Future Feature
OC-3/12 (UPSR), 1000-SX/LX/ZX, 100-LX/TX
OC-3/12 (UPSR)
1-way VT1.5-------->
DS1, E1, DS3, EC-1, TransMUX, OC-3/12/48
(UPSR, 1+1, 0x1) and OC-48 BLSR, 1000-SX/
LX/ZX, 100-TX/LX, FC-DATA
DS1, EC-1, TransMUX, OC-3/12/48 (1+1, UPSR,
0x1), 100-TX/LX (LNW74 only)
OC-48 Low-Speed OLIU (0x1Sn) (non-
VLF Mains only)
1-way STS-n --------------------->
1-way VT1.5-------->
DS1, E1, DS3, EC-1, TransMUX, OC-3/12/48
(UPSR, 1+1, 0x1Sn) and OC-48 BLSR, 1000-SX/
LX/ZX, 100-TX/LX, FC-DATA
DS1, EC-1, TransMUX, OC-3/12/48 (1+1, UPSR,
0x1Sn), 100-TX/LX (LNW74 only)
1000-SX/LX (LNW67/68)
1-way STS-n ---------------------> 100-TX/LX, 1000-SX/LX/ZX, OC-3/12/48 (1+1,
UPSR, 0x1, 0x1Sn), OC-48 BLSR
OC-3/12/48 (UPSR) and OC-48 BLSR w/ NUT 1-way unswitched STS-n-------->
100-TX/LX- non private line
1-way STS-n --------------------->
1-way unswitched STS-n-------->
1000-SX/LX/ZX, OC-3/12/48 (1+1, UPSR, 0x1,
0x1Sn) and OC-48 BLSR
1000-SX/LX/ZX, OC-3/12/48 (UPSR) and OC-48
BLSR w/NUT
100-FEPL (private line)
1-way STS-n --------------------->
1-way unswitched STS-n-------->
FC-DATA (FC/FICON/ESCON)
1000-SX/LX/ZX, OC-3/12/48 (1+1, UPSR, 0x1,
0x1Sn) and OC-48 BLSR
OC-3/12/48 (UPSR) and OC-48 BLSR w/ NUT
--
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
5 - 5 9
Allowable Cross-Connects
From
1-way STS-n --------------------->
TransMUX (LNW18 and LNW20)
1-way STS-n --------------------->
1-way VT1.5 ------->
DS1/E1
1-way STS-n --------------------->
1-way VT1.5 ------->
DS3
1-way STS-n --------------------->
EC-1
1-way STS-n --------------------->
System Planning and Engineering
To
OC-3/12/48 (1+1 and UPSR) and OC-48 BLSR
TransMUX, DS1, OC-3/12/48 (1+1 and UPSR) and OC-48 BLSR
TransMUX, DS1, OC-3/12/48 (1+1 and UPSR) and OC-48 BLSR
DS1/E1, TransMUX, OC-3/12/48 (1+1, UPSR,
0x1, 0x1Sn) and OC-48 BLSR
DS1/E1, TransMUX, OC-3/12/48 (1+1 and
UPSR) and OC-48 BLSR
DS3, OC-3/12/48 (1+1, UPSR, 0x1, 0x1Sn) and
OC-48 BLSR
EC-1, DS1, TransMUX, OC-3/12/48 (1+1, UPSR,
0x1, 0x1Sn) and OC-48 BLSR
...........................................................................................................................................................................................................................................................
5 - 6 0
365-372-300
Issue 8.0, September 2006
System Planning and Engineering
Assignment of VT Bandwidth on OC-48 and OC-12 High-speed
Interface
............................................................................................................................................................................................................................................................
Overview
When using the OC-48 OLIU (LNW26B, LNW28, LNW77,
LNW121B-LNW159B) or OC-12 OLIU (LNW48, LNW50, and LNW
54) in M1 and M2, for VT add/drop cross-connections, VT hairpin cross-connections, and VT pass through cross-connection, the following restrictions apply
.
Important!
The following restrictions do not apply to the
LNW27, LNW29, LNW76, and LNW221-LNW259 OC-48 OLIU circuit packs.
VT Fabric Capacity
The VT fabric on the main OC-12/48 OLIU circuit packs (M1 and M2) supports several types of VT cross-connections.
• VT add/drop from/to OC-N OLIUs in the Function Unit and
Growth slots.
• VT add/drop from/to DS1 ports.
• VT hairpins.
• VT pass-throughs on the MAIN OC-12/48 OLIUs in M1 and M2.
The total provisionable bidirectional VT cross-connect capacity of 336
VT1.5s is shared among the four types of VT cross-connections.
Important!
The "dual tatrib" modes (MONEF and SPLTEF) of
VT test access are not possible when the system is equipped with small/medium VT fabric Main OLIUs, such as those listed above.
For more information refer to the
Source and Destination Restrictions
The user can not provision a VT1.5 connection whose source STS is the same as the destination STS of another VT1.5 connection. Source and destination are not a function of the src_aid and dest_aid in the
ENT-CRS-rr command. Rather source and destination are determined based on the relative STS number. The lower STS number is designated as the source and the higher STS number is designated as the destination based on the following ordering of the slots, main < fna
< fnb < fnc < fnd < growth.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
5 - 6 1
Assignment of VT Bandwidth
System Planning and Engineering
The one exception to this rule is for cross-connections to DS1 ports on the LNW6 and LNW7 packs. For these connections the OC-N port is always the source and the DS1 port is always the destination. The following example illustrates the restriction. Note, the commands are not syntactically correct. They are intended only to show the aids.
Example
The ENT-CRS-VT1 command uses the following aid format for the src_aid and dest_aid parameters. {group}-{line}-{STS}-{VTG}-
{VT1.5}.
Step 1:
Ent-crs-vt1:b-1-1-1-1,a-1-1-1-1 cross-connects a VT1.5 in FN Group A to a VT1.5 in Function Group B. According to the rule defined above, the lower STS channel (a-1-1) is designated the source and the higher
STS channel (b-1-1) is designated the destination.
Step 2:
Ent-crs-vt1:b-1-1-1-2,c-1-1-1-2 cross-connects a VT1.5 in FN Group B to a VT1.5 in Function Group C.
In the above example, the cross-connection in step 2 (b-1-1-1-1 to c-1-
1-1-2) would be denied because the source STS (b-1-1) is the same as the destination STS channel (b-1-1) in the cross-connect established in step 1 (b-1-1-1-1 to a-1-1-1-1).
Pass-through Restrictions
If the Main slots are equipped with OC-48 OLIU (LNW26 only-- not supported in R6.0) or OC-12 OLIU (LNW48, LNW50, and LNW 54) circuit packs provisioned to support VT1.5 signals in up to 6 STS-1 signals, VT pass-through cross-connections on the Main circuit packs can in some cases conflict with VT add/drop cross-connections and VT hairpin cross-connections. This restriction, however, cannot be characterized by a set of rules. Requests to establish a VT crossconnection that would result in a conflict between a VT pass-through cross-connection on the main and a VT add/drop or VT hairpin crossconnection will be denied.
...........................................................................................................................................................................................................................................................
5 - 6 2
365-372-300
Issue 8.0, September 2006
System Planning and Engineering
Synchronization
Overview
............................................................................................................................................................................................................................................................
Purpose
This section describes synchronization features and functions for the
DMX Access Multiplexer.
Contents
The following synchronization topics are discussed in this section:
Network Synchronization Environment
Sync Messaging Feature Details and Options
Frequently Asked Network Timing Distribution Questions
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
5 - 6 3
System Planning and Engineering
Network Synchronization Environment
............................................................................................................................................................................................................................................................
Overview
Careful consideration should be given to proper design of the SONET network’s synchronization environment. Proper synchronization engineering minimizes timing instabilities, maintains quality transmission network performance, and limits network degradation due to unwanted propagation of synchronization network faults. The synchronization features of the DMX are designed to complement the existing and future synchronization network and allow it not only to make use of network timing but also to take on an active role in facilitating network synchronization.
Published sources
A number of published sources give generic recommendations on setting up a synchronization network. The DMX is designed to operate in a network that complies with recommendations stated in GR-253-
CORE and the following documents:
• GR-436-CORE, Digital Synchronization Network Plan
• GR-378-CORE, Generic Requirements for Timing Signal
Generators (TSG)
• ANSI T1.101, Synchronization Interface Standards for Digital
Networks
• GR-1244-CORE, Clocks for the Synchronized Network: Common
Generic Criteria.
...........................................................................................................................................................................................................................................................
5 - 6 4
365-372-300
Issue 8.0, September 2006
Network Synchronization Environment
Recommendations
System Planning and Engineering
The following are some key recommendations from the documents listed above. For further detailed explanation, the sources should be consulted directly.
1.
A node can only receive the synchronization reference signal from another node that contains a clock of equivalent or superior quality (Stratum level).
2.
The facilities with the greatest availability (absence of outages) should be selected for synchronization facilities.
3.
Where possible, all primary and secondary synchronization facilities should be diverse, and synchronization facilities with the same cable should be minimized.
4.
The total number of nodes in series from the Stratum 1 source should be minimized. For example, the primary synchronization network would ideally look like a star configuration with the
Stratum 1 source at the center. The nodes connected to the star would branch out in decreasing Stratum level from the center.
5.
No timing loops may be formed in any combination of primary and secondary facilities.
Stratum 3 Timing
Generator
DMX supports a Stratum 3 Timing Generator (TG3) embedded in each high speed (MAIN) Main Switch pack (LNW80), OC-12, OC-48, and
OC-192 optical interface circuit pack. The TG3 operates with an internal oscillator of ± 4.6 ppm long-term accuracy in the free running mode, while in holdover the accuracy is ± .37 ppm over the full -40 to
+65 o
C temperature range. The TG3 should be used according to the recommendations in the documents referenced previously.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
5 - 6 5
System Planning and Engineering
Synchronization Features
............................................................................................................................................................................................................................................................
Overview
Synchronization is an important part of all SONET products. DMX is designed for high performance and reliable synchronization and can be used in a number of synchronization environments. Each DMX can be provisioned to free run from an internal oscillator, line time from an incoming high-speed interface, or get external timing from the digital synchronization network via DS1/E1 references. DMX also supports distribution of timing references using DS1/E1 timing outputs.
Synchronization features
DMX supports three synchronization reference configurations:
•
External Timing
from a Stratum 3 or better office clock (typical
CO installations should be synchronized with DS1 or E1 timing references from a Stratum 3).
•
Line Timing
from incoming high-speed OC-12/OC-48/OC-192 signal (for small COs or remote sites).
•
Line Timing from tributaries
derived from incoming low-speed
OC-3/12/48 signal.
•
Free Running
from the multiplexer’s internal Stratum 3 Timing
Generator (no synchronization inputs).
These timing modes are supported by the embedded Stratum 3 Timing
Generator in the OC-12, OC-48 or OC-192 circuit pack. The four basic timing modes can be combined into various network configurations.
Line timing from high-speed lines is not available when using the
LNW80 in the MAIN slots; line timing from tributaries is available when using the LNW80.
Internal timing functions such as reference interfaces, the on-board clock elements, and timing distribution, are provided by the Stratum 3
Timing Generator. The timing generator distributes clock and frame signals, derived from the selected reference source, to the transmission packs.
...........................................................................................................................................................................................................................................................
5 - 6 6
365-372-300
Issue 8.0, September 2006
Synchronization Features
External timing mode
System Planning and Engineering
In external timing mode, the timing generator accepts two DS1 or E1 references from an external Stratum 3 or better clock. This Stratum 3
(or better) clock would typically be traceable to a primary reference source (PRS). The DS1/E1 references from the clock synchronize the local DMX with other network equipment operating under the same primary clock source. A high-stability digital phase-locked loop
(DPLL) removes transient impairments on the DS1/E1 references for improved jitter performance.
The PRS is equipment that provides a timing signal whose long-term accuracy is maintained at 10
-11
or better with verification to universal coordinated time, and whose timing signal is used as the basis of reference for the control of other clocks in the network. Universal coordinated time is a time and frequency standard maintained by the
US National Institute of Standards and Technology.
Line timing mode
In line timing mode, the TG3 derives local shelf timing from the incoming service OC-12, OC-48, or OC-192 high-speed signal in the
Main slot. The DPLL serves to remove any timing transients for improved network jitter performance. When provisioned for automatic protection switching, if one of the OC-n references is corrupted or unavailable, the TG3 will make a revertive or nonrevertive protection switch to the other reference without causing timing degradations.
Beginning in R4.0, synchronization reference mode switching can be either revertive or nonrevertive. You can also provision MAIN-1-1 or
MAIN-2-1 as the primary reference. If all OC-n timing signals are lost, the TG3 will switch to holdover mode. The TG3 will normally switch back to the line timing mode when a reference is no longer corrupted and clock mode switching is set to revertive. Yet it can be provisioned to require a manual switch. Switching between the two Main OC-n reference inputs can also be done using a manual command.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
5 - 6 7
Synchronization Features
System Planning and Engineering
Line Timing from Optical
Tributary Packs (R7.0)
DMX can derive timing references from low-speed/tributary optical interfaces beginning in R7.0. Prior to R7.0, line timing references could only be derived from the signals entering the Main circuit packs. DMX can now derive timing references form any optical line entering Main,
Function Unit, or Growth slots.
All optical circuit packs can derive a 6.48MHz timing signal from an incoming optical line.
There is a single line timing reference clock signal from each Function
Unit/Growth slot to the MAIN/Timing Generator (TG). On a Function
Unit/Growth circuit pack with multiple ports, port selection is made on the Function Unit/Growth pack, not on the MAIN/TG. Non-VLF
MAINs have 2 MAIN, 2 Growth and one Function group line reference input. Function group slot selection and line reference protection switching is done on the MAIN circuit pack, but remains external to
TG. VLF MAINs have separate inputs for all MAIN, Growth and
Function Unit slots. Slot selection and line reference protection switching is done within the TG. DS1/E1 Sync Out is always derived from the provisioned line timing source.
Free running mode
In free running mode, no mode switching is performed. The timing generator derives timing from a high stability temperaturecompensated, voltage-controlled crystal oscillator that has an end of life performance of +/- 4.6 ppm. This oscillator is capable of Stratum 3 accuracy. Only one DMX in a subnetwork can be provisioned in the free running mode. All other DMX NEs in the subnetwork must be line timed to this free running system to avoid performance degradation.
DS1/E1 timing output
DMX also supports a DS1 or an E1 timing output feature that facilitates network timing distribution. E1 timing outputs are available with the
LNW59 VLF Main. The DS1/E1 timing output is derived from the OCn line rate, so it is not subjected to multiplexing or pointer processing effects. The result is a DS/E1 traceable to the far-end source with extremely low jitter and wander. The timing output can be locked to an
OC-n line or the OC-n source can be automatically selected using synchronization messages. In either case Threshold AIS may be enabled to insert AIS if the synchronization message of the OC-n source matches a provisioned threshold.
The frame format on the DS1 output is provisionable as superframe format (SF) or extended SF (ESF). The E1 frame format can be provisioned as FAS or CRC4. The DS1/E1 is a framed all-ones signal under normal conditions or an AIS signal under failure conditions.
...........................................................................................................................................................................................................................................................
5 - 6 8
365-372-300
Issue 8.0, September 2006
Synchronization Features
System Planning and Engineering
SDH Synchronization
(R7.0)
Beginning in R7.0, and with the use of the LNW59 VLF Main pack,
DMX supports E1 timing references. SDH synchronization conforms to industry standards for frequency accuracy, pull-in, hold-in and pullout ranges, wander, jitter, noise tolerance, noise transfer, transient response, holdover performance (per ITU-T G.813), and for SDN Sync
Status Messaging (per ITU-T G.704).
Dual Reference Monitoring
(DRM) (R7.0)
Beginning in R7.0, and with the use of VLF Mains, both external timing references are monitored simultaneously, even when the Timing
Generator (TG) is in holdover mode. So, if an external reference fails, the Out of Lock (OOL) status of the standby reference is already known and the decision to switch to the standby reference can be made with certainty that the standby reference is not in an OOL condition. If the TG is in holdover mode, or if it has switched references with revertive reference switching enabled, it can monitor the OOL reference(s) for a non-OOL condition and switch to the good reference with certainty that the reference is in fact not in an OOL condition. It will also autonomously clear the OOL alarm.
With non-VLF MAINs both external timing references are monitored for LOS, LOF, AIS, BER & EOOF failures, but only the active reference can be monitored for frequency offset OOL failures, and only when the TG is locked to the reference. Frequency offset of either external reference cannot be monitored when the TG is in holdover or freerunning modes.
When a failure of the active reference occurs, if reference switching is enabled, and if the standby reference doesn’t have an LOS, LOF, AIS,
BER & EOOF failure, the NE switches to the standby reference and locks to it, and then monitors its frequency offset for an OOL condition. If the standby reference does have an OOL failure, the TG goes into holdover mode and issues a major sync alarm for both references failed (subject to ASAP provisioning).
Holdover mode
When line or external timing is used, in case of unprotected synchronization reference failure, the TG3 will switch to “holdover mode” and continue to provide system timing using the internal oscillator to maintain the last known good reference frequency. If the
DS1/E1 timing output is enabled for network synchronization, DS1 or
E1 AIS is inserted on detection of unprotected optical reference failure.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
5 - 6 9
System Planning and Engineering
Network Configurations
............................................................................................................................................................................................................................................................
Overview
The following pages detail the three different network configuration types: free running/line timing, external timing/line timing, and external timing.
Free running/line timing configuration
For initial SONET deployment with DS1 and/or DS3 low-speed interfaces, minimum first cost may be a primary concern. The free running/line timing network can operate without an external clock source, so the expense of connecting to one is eliminated. This configuration may be useful for initial access transport and customer location applications, and also meets the needs of an end-office trunk facility. This configuration should not be used to provide OC-n timing distribution or where SONET interconnections to other SONET networks are needed.
The local DMX times its transmitted signals at the low- and high-speed interfaces from the internal +/- 4.6 ppm of the Stratum 3 timing generator. The remote DMX recovers timing from the incoming OC-n signal and uses this timing for its transmitted signals.
Certain interconnected equipment may be sensitive to such jitter and this configuration should not be used in cases where it would cause a problem for that equipment. In particular, downstream equipment containing Stratum 3 or better clocks could be sensitive to this jitter.
...........................................................................................................................................................................................................................................................
5 - 7 0
365-372-300
Issue 8.0, September 2006
Network Configurations
System Planning and Engineering
The figure below shows free running/line timed configuration in a ring network.
Figure 5-14 Free Running/Line Timed Configuration - Ring
Network
TG3
DMX
Line-Timed
Note
OC3/12/48/192
TG3
DMX
Free Running
Note
OC3/12/48/192 OC3/12/48/192
TG3
OC3/12/48/192
DMX
Line-Timed
Note
Note: DS1/DS3/EC-1/E1/Ethernet/OC-3/OC-12/OC-48
TG3
DMX
Line-Timed
Note nc-dmx2-025
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
5 - 7 1
Network Configurations
Present Mode of Operation
System Planning and Engineering
Line timing from Main interfaces vs. line timing from tribs
The figure below shows various DMX shelves in line timing mode. The top portion of the figure shows the present mode of operation where line timing references must be derived from optical lines entering the
Main network interface circuit packs.
The bottom portion of the figure represents DMX’s capability to derive timing references from optical lines entering both the Main and tributary interface circuit packs. Line timing from tributary interfaces is made possible in R7.0. Prior to R7.0, DMX could only derive timing references from the Main network interface circuit packs. DMX can utilize tributary line timing when equipped with VLF Mains (LNW59),
Non-VLF Mains (all other Main interface optical packs), and headless
Main (LNW80) packs.
As shown in the top right of the figure below, the only two shelves that can serve as line timing sources in the present mode of operation are the two furthest to the right. This is because they are connected Main to
Main, while the other shelves are transmitting optical signals from tributary interfaces to Main interfaces (or vice versa). The bottom portion of the figure shows how tributary line timing allows any DMX shelf in the topology pictured to serve as the line timing source.
Figure 5-15 Tributary line timing references
Timing Source must be either of these two nodes
OC-48 1 + 1 OC-48 1 + 1
OC-483 1 + 1
OC-48 1 + 1
Main to Trib
Timing From Tribs
M1
OC-48 1 + 1
M2
Main to Trib
Main to Trib i b
T r s
OC-48 1 + 1
Trib to Trib
Main to Trib Main to Main
Timing Source can be at any node
OC-48 1 + 1
Main to Trib
OC-483 1 + 1
Main to Main
MA-DMXAPG-043
...........................................................................................................................................................................................................................................................
5 - 7 2
365-372-300
Issue 8.0, September 2006
Network Configurations
System Planning and Engineering
External timing/line timing configuration
The external timing/line timing configuration integrates access transport and customer location networks into the digital synchronization network as required by the SONET standard. This application is ideal for networks where only one location has a building integrated timing supply (BITS) clock, for example, access transport.
The network is synchronized to a local central office clock via DS1 references. The local office clock should be Stratum 3 or better, with timing traceable to a primary reference source. The local DMX times its transmitted signals at the low- and high- speed interfaces from the internal oscillator that is locked on the external reference. The remote
DMX recovers timing from the incoming OC-n (OC-3/12/48/192, tributary or Main interface) signal and uses this timing for its transmitted signals.
External timing is required when EC-1 low-speed interfaces are used to interconnect the local DMX with other SONET equipment. Thus, the external timing/line timing configuration should be the long-term goal for all access transport and customer location applications.
In a ring topology, synchronization messaging allows automatic synchronization reconfiguration in the event of a fiber or equipment failure.
The figure below shows external timing/line timing in a ring configuration.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
5 - 7 3
Network Configurations
System Planning and Engineering
Figure 5-16 External Timing/Line Timing - Ring Network
External Clock
(Stratum 3 or better)
DS1
TG3
TG3
OC3/12/48/192
DMX
Line-Timed
Note
DMX
External-Timed
Note
OC3/12/48/192 OC3/12/48/192
TG3
DMX
External-Timed
Note
Note: DS1/DS3/EC-1/E1/Ethernet/OC-3/OC-12/OC-48
OC3/12/48/192
TG3
DMX
Line-Timed
Note nc-dmx2-024
...........................................................................................................................................................................................................................................................
5 - 7 4
365-372-300
Issue 8.0, September 2006
Network Configurations
System Planning and Engineering
External timing configuration
The external timing configuration uses external DS1or E1 timing to each DMX in the network. Since it requires local office clocks at each site, it is most suited to interoffice applications. A DMX network may have all DS1/E1 references traceable to a common primary reference source (for example, outstate trunking) referred to as synchronous, or to multiple primary reference sources (for example, a carrier-to-carrier interface). The multiple primary reference source is referred to as plesiochronous operation. The figure below shows an external timing configuration.
A tributary signal (for example, DS1) that traverses several plesiochronous regions may encounter increased STS-1 and VT pointer adjustments compared to that encountered in a synchronous environment. These pointer adjustments may increase jitter on the tributary when dropped from the SONET network. While standard jitter generation limits are perfectly acceptable for most service needs, some data services or other equipment may be particularly sensitive to jitter-induced degradations. Therefore, it is generally desirable to minimize the number of plesiochronous regions within a network, through Stratum 1 clock traceability and line timing of remote SONET elements.
Figure 5-17 External Timing Configuration - Ring Network
PRS Traceable
External Clock
(Stratum 3 or better)
DS1
External Clock
(Stratum 3 or better)
DS1
PRS Traceable
TG3
OC-3/12/48/192
DMX
External-Timed
Note
TG3
DMX
External-Timed
Note
OC-3/12/48/192 OC-3/12/48/192
TG3
OC-3/12/48/192
DMX
External-Timed
Note
TG3
DMX
External-Timed
Note
DS1
PRS Traceable
External Clock
(Stratum 3 or better)
DS1
Note: DS1/DS3/EC-1/E1/Ethernet/OC-3/OC-12/OC-48
DS1
External Clock
(Stratum 3 or better)
PRS Traceable nc-dmx2-023
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
5 - 7 5
Network Configurations
System Planning and Engineering
External timing with DS1/E1 timing output
External timing may be combined with the DS1/E1 timing output feature as shown in the figure below (E1 not pictured). Note that the
DS1/E1 timing output feature and plesiochronous operation are mutually exclusive. Each of the network topologies (linear, hubbing, ring) can use external timing.
Figure 5-18 DS1/E1 Timing Output and Plesiochronous Timing
Configurations
Clock Source
(Stratum 3 or better)
DS1
External Clock
(Stratum 3 or better)
DS1 DS1 Timing out
TG3
OC-3/12/48/192
Metropolis
DMX
®
TG3
Metropolis
®
DMX
DS1/DS3/EC-1/E1/Ethernet/OC-3/
OC-12/OC-48
CO
(a) External Timing Configuration
DS1/DS3/EC-1/E1/Ethernet/OC-3/
OC-12/OC-48
CO
Clock Source
(Stratum 3 or better)
DS1
May be Plesiochronous
External Clock
(Stratum 3 or better)
DS1
TG3
OC-3/12/48/192
Metropolis
DMX
®
TG3
Metropolis
®
DMX
DS1/DS3/EC-1/E1/Ethernet/OC-3/
OC-12/OC-48
CO
DS1/DS3/EC-1/E1/Ethernet/OC-3/
(b) External Timing Plesiochronous
OC-12/OC-48
CO nc-dmx2-022
...........................................................................................................................................................................................................................................................
5 - 7 6
365-372-300
Issue 8.0, September 2006
System Planning and Engineering
Timing Distribution
............................................................................................................................................................................................................................................................
Network timing distribution
DS1 signals have long been used to pass timing information through the network synchronization hierarchy. With R7.0 and the LNW59
VLF Main, E1 timing outputs are also supported. These DS1/E1 timing references should be transmitted between master and slave clock sources over the most reliable facilities available. In some cases, these
DS1/E1 signals also carry traffic. The facility of choice has evolved from T-carrier through asynchronous lightwave systems to SONET lightwave systems. As these systems are upgraded to SONET systems, timing distribution plans should be revisited to ensure the quality of the timing signals are not degraded. With proper planning, SONET can be used to improve the overall quality of the network timing.
Interoffice timing distribution
One way SONET can be used to improve the quality of interoffice network timing is through the use of OC-n (OC-3/12/48/192) timing distribution. DMX supports the evolution to interoffice OC-n timing distribution by providing a DS1/E1 timing output derived from the incoming OC-n signal. The DS1/E1 timing output is traceable to the clock source that times the DMX subnetwork and has extremely low jitter and wander. This is true regardless of the number of DMX systems connected in the network. This DS1/E1 can be fed to the local
BITS clock which subsequently times the local DMX and the other equipment in the office. If a BITS clock is not available in the office, the DS1/E1 timing output can be used to time other equipment
(including another DMX) directly. DMX can provide DS1/E1 timing outputs in all supported topologies (for example, add/drop and ring) in the main slots prior to R7.0. R7.0 adds support for line timing from tributary optical interfaces, allowing DMX to provide DS1 timing outputs even when equipped with the LNW80 headless main. E1 timing outputs are available only when the LNW59 Main is used.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
5 - 7 7
Timing Distribution
System Planning and Engineering
With OC-n timing distribution, the OC-n line signal, rather than a DS1/
E1 multiplexed into the SONET payload, will provide a timing transport mechanism better suited to a complex, heavily interconnected
SONET network. In this configuration, a DS1 reference from the CO
BITS clock still times the OC-n transmitted to the remote site. At the remote site, a DS1/E1 output reference is created directly from the received OC-n signal, as shown in the figure below (E1 not pictured).
Figure 5-19 OC-n (OC-3/12/48/192) Derived DS1 Timing Reference
Slave Clock
DS1 out
DS1
External Clock
(Stratum 3 or better)
DS1
OC-3/12/48/192
Other
Network
Elements
TG3
DMX
DS1/DS3/EC-1/E1/Ethernet/OC-3/
OC-12/OC-48
CO
TG3
DMX
DS1/DS3/EC-1/E1/Ethernet/OC-3/
OC-12/OC-48
CO nc-dmx2-021
Potential advantages
OC-n (OC-3/12/48/192) timing distribution has several potential advantages. It preserves transport bandwidth for customer services and guarantees a high-quality timing signal. Also, as the CO architecture evolves to replace DSX interconnects with SONET EC-1 interconnects and direct OC-n interfaces, OC-n distribution becomes more efficient than multiplexing DS1 references into an access facility in the CO.
A previous drawback to using OC-n timing distribution was that the network timing failures could not be communicated to downstream clocks via DS1 AIS, since the DS1 signal does not pass over the OC-n interface. A standard SONET synchronization messaging scheme to convey synchronization failures is now in place. The DMX multiplexer supports this synchronization messaging scheme. With this option, clock Stratum levels can be passed from NE to NE, allowing downstream clocks to switch timing references without creating timing loops, if a network synchronization failure occurs. If a quality timing reference is no longer available, the DMX sends AIS over the DS1 interface. If the local OC-n lines fail, DMX outputs AIS on the DS1 output or an upstream DMX enters holdover.
...........................................................................................................................................................................................................................................................
5 - 7 8
365-372-300
Issue 8.0, September 2006
Timing Distribution
System Planning and Engineering
Access network timing distribution
OC-n (OC-3/12/48/192) timing distribution can also be used in access networks or to small COs. In this configuration, a DS1 reference from the CO BITS clock still times the OC-n transmitted to the remote site.
The line timing capability of DMX provides the ability to recover OC-n timing. The DS1 timing output feature can be used to also extend timing to customer networks or remote sites. In this case, the DS1 timing output may be used to time switch remotes, DMX shelves, or other local equipment directly. Ideally, the equipment can provide an external timing reference. Otherwise, the signal must be input to a traffic DS1 port on the external equipment which will tie up some of this equipment’s bandwidth. In this configuration, it is important that the DS1 reference to the DMX in the CO be traceable to the same clock used to source the DS1s being carried to the customer site or small CO.
If it is not, slips may occur.
Alternate timing sources
Although an ideal source of timing, OC-n timing distribution, via a
DS1 timing output, cannot be used to provide timing in all applications.
In cases where the local equipment is not provided with an external timing reference input, or in some private networks where the timing is to be distributed from another private network location, timing may be distributed via traffic-carrying DS1s. In these applications, a stable
DS1 timing source can be achieved by ensuring that all elements in the
SONET network are directly traceable to a single master clock via line timing. In this environment, the high-performance desynchronizer design of the DMX allows a DS1 timing reference to be carried as a multiplexed DS1 payload.
It is recommended that, where possible, the DS1 sources (switch, PBX, or other equipment) be traceable to the same timing source used to time the DMX SONET network. Multiplexed DS1 reference transport is also consistent with current planning and administration methods.
Applications include passing synchronization from the public switched network to a PBX-based private network (see figure on following page) and synchronizing an end-office remote switch to a larger office’s host switch.
Note:
Synchronous operation via line timing eliminates the generation of VT pointer adjustments, thus maintaining the phase stability needed for a high-quality DS1 timing reference. Cross-connecting at the STS-1 level also eliminates the VT pointer adjustments. While the design of the
DMX maintains jitter/wander within standard DS1 interface requirements, even in the presence of VT pointer adjustments, and
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
5 - 7 9
Timing Distribution
System Planning and Engineering
while the DS1 is likely to be stable enough for most equipment to use as a timing reference, some equipment may have more stringent stability requirements for its timing references.
Figure 5-20 Timing from Multiplexed DS1
External Clock
(Stratum 3 or better)
DS1
TG3 TG3
OC-N
DMX
Customer
Network
DS1
DS1 Carrying Data and Used as a
Timing Reference
PBX
RT
Signal may not go directly from DMX to the POX, but may pass through another piece of equipment such as a DDM-2000 OC-3 multiplexer
®
DMX = Metropolis DMX Access Multiplexer
DMX
DS1
CO nc-dmx2-020
...........................................................................................................................................................................................................................................................
5 - 8 0
365-372-300
Issue 8.0, September 2006
System Planning and Engineering
Synchronization Messaging
............................................................................................................................................................................................................................................................
Overview
DMX provides a synchronization messaging feature to ensure the integrity of network synchronization during both normal and abnormal conditions. Through the use of synchronization messaging, the current quality of the timing source can be conveyed from one DMX
Multiplexer to the next. This capability allows the DMX to automatically change its timing reference in order to always maintain the highest quality timing available. The capability also allows the
DMX to inform a local BITS clock when the DS1/E1 timing output has been degraded and should no longer be used as a reference. This synchronization messaging feature is compliant with the scheme developed in the ANSI T1X1 standards committee.
Also, the same parameter used to chose between DS1 and E1 timing outputs is employed to choose between SONET sync messaging (ANSI
T1X1 mentioned above) and SDH sync messaging.
Applications
The applications that are currently supported with the synchronization messaging feature can be divided into three categories:
• DS1/E1 timing output integrity
• Automatic synchronization reconfiguration
• Synchronization provisioning integrity.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
5 - 8 1
Synchronization Messaging
System Planning and Engineering
DS1 timing output integrity
The derived DS1 timing outputs are typically used as a synchronization reference to a BITS clock which provides the timing reference to an externally-timed DMX Multiplexer. The synchronization reference is derived from the SONET transmission facility which is synchronized from an upstream timing reference. In this way, the timing from the
BITS clock in one office (master) is distributed to the next office
(slave) using the SONET transmission facilities between them as the synchronization vehicle.
The BITS are typically capable of synchronizing to a Stratum 3 or better accuracy. The DMX equipped with the embedded Stratum 3 timing generator is capable of synchronizing to a +/- 4.6 ppm clock or better. The Stratum timing hierarchy requires that clocks of equal or better Stratum level be used to synchronize other clocks. In this way, the Stratum timing hierarchy is preserved under all failure conditions.
Under non-failure conditions, the DMX does not introduce its own internal timing source onto the SONET facility, but merely transfers the quality of its timing reference. A failure of all derived DS1 timing references to the BITS at the master office will cause the BITS to enter holdover mode, whose minimum accuracy is dependent on its internal clock. If the BITS internal clock is of equal or better Stratum level than the DMX, the externally-timed DMX will use this reference to synchronize all outgoing SONET transmission facilities. This preserves the required hierarchical structure of the timing network and should be maintained at all times.
If the externally-timed DMX at the master office enters holdover due to a disconnected reference cable or a local BITS failure, the quality of the derived DS1 timing output at the slave office will now be traceable directly to the DMX. The Stratum timing hierarchy will be violated if the slave office BITS requires timing accuracy of better Stratum level than that provided by the master DMX’s internal clock. Because the
DMX contains the embedded Stratum 3 Timing Generator, Stratum 3 accuracy will be maintained indefinitely. This provides acceptable timing for Stratum 3 NEs at slave offices.
Another scenario that will cause the Stratum timing rules to be violated is when at least one line-timed DMX exists at a site between the master and slave offices. In this scenario, a fiber cut between the master office and the line-timed site will cause the line-timed DMX to enter holdover
(with accuracy dependent upon its internal clock). If the BITS at the slave office requires a higher accuracy clock than that generated by the
DMX in holdover, the Stratum timing hierarchy will be violated.
...........................................................................................................................................................................................................................................................
5 - 8 2
365-372-300
Issue 8.0, September 2006
Synchronization Messaging
System Planning and Engineering
Automatic synchronization reconfiguration
SONET was designed to operate optimally in a synchronous environment. Although plesiochronous and asynchronous operation can be supported through the use of pointer adjustments, transmission quality is affected by the generation of additional jitter and wander due to pointer adjustments. Because of this, it is desirable to maintain synchronous operation whenever possible. Through the use of synchronization messages, the quality of the different timing references can be made available at each DMX NE. The DMX shelf can be optioned to determine the best timing reference available and switch to that reference. Through this mechanism, the synchronous operation of the subnetwork can be maintained. The switching of timing references is hitless, and the synchronization messages also allow it to be done without creating timing loops in the process.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
5 - 8 3
Synchronization Messaging
System Planning and Engineering
Access ring network
Under normal operation in the access ring network pictured in the figure below, the ring has one DMX externally timed and the others line timed in one direction (clockwise or counterclockwise). The result is that the ring is again operating synchronously. The ring already provides self-healing of the traffic, so it is especially important to maintain synchronous operation during this type of failure to prevent service degradation due to increased jitter and wander.
Figure 5-21 Synchronization Reconfiguration - Access Ring
Normal Failure/Reconfiguration
PRS
Traceable
BITS
PRS
Traceable
BITS
DMX DMX
DMX DMX DMX DMX
DMX
DMX
Sync Flow nc-dmx2-019
Synchronization provisioning integrity
A welcome side feature of synchronization messaging is that it helps prevent provisioning errors. Provisioned timing loops on DMX
Multiplexers will be quickly detected through the synchronization messaging algorithm and prevented by forcing a shelf into holdover.
The system can then be reprovisioned correctly.
...........................................................................................................................................................................................................................................................
5 - 8 4
365-372-300
Issue 8.0, September 2006
System Planning and Engineering
Sync Messaging Feature Details and Options
............................................................................................................................................................................................................................................................
Overview
As mentioned previously, SONET sync messaging is used to communicate the quality of the subnetwork timing throughout the subnetwork. This is done using bits 5-8 of the S1 byte in the SONET overhead. If a DMX shelf is deriving timing from a given OC-n interface, and sync messaging is enabled on that interface, the system interprets the received message to determine the system’s timing status.
The system also determines the state of the DS1 output, if the DS1 output is enabled, by forcing a DS1 AIS on the DS1 sync outputs if the timing status received on the OC-n interface is below a provisioned quality threshold. DMX also transmits over the particular OC-n interface, and all other OC-n interfaces that are enabled for sync messaging, the appropriate message indicating the quality of its timing and its usability.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
5 - 8 5
Sync Messaging Feature Details and Options
Sync messages using
S1 byte
System Planning and Engineering
The following table lists the associated internal timing status and DS1/
E1 output states that are associated with sync messages (using the S1 byte) received from the OC-n interface when sync messaging is enabled. The same parameter used to chose between DS1 and E1 timing outputs is employed to choose between SONET sync messaging and SDH sync messaging. Messages are listed from low to high quality.
Table 5-10 Sync Messages with the S1 Byte
Received Message
Don’t Use (DUS)
Traceable Stratum 4 (ST4)
(Note 4)
Traceable SONET Clock w/S3-TG
(SMC)
Traceable Stratum 3 (ST3) (Note 3)
Traceable Stratum 3E (ST3E)
Traceable Transit Node Clock (TNC)
Traceable Stratum 2
Sync Trace Unknown (STU)
PRS Traceable (Note 3)
Active Timing
Mode (Note 1)
Holdover
Holdover
Holdover
OK to use
OK to use
Ok to use
OK to use
OK to use
OK to use
DS1/E1
Output State
(Note 2)
AIS
AIS
AIS
AIS
AIS
AIS
Good
Good
Good
Quality
Level
9
8
7
4
3
6
5
2
1
Notes:
1.
This column applies only when provisioned for line timing mode.
2.
This table represents DS1/E1 output AIS threshold equal to level
4.
3.
The embedded TG3 is Stratum 3.
4.
As of R7.0, Telcordia has not assigned a value to the S1 byte for
ST4.
...........................................................................................................................................................................................................................................................
5 - 8 6
365-372-300
Issue 8.0, September 2006
Sync Messaging Feature Details and Options
System Planning and Engineering
Disabling sync messaging
Sync messaging using the SONET S1 byte can be disabled on a per
OC-n interface basis. A
Don’t Use for Service (DUS)
message is transmitted on bits 5-8 of the S1 byte if this is done.
“Don’t use” (DUS)
The
DUS
message is sent to indicate that its timing is not suitable for synchronization (for example, back towards the line timing source).
External timing with
SYNC OUT
When DMX is configured for external timing and its DS1/E1 output port is provisioned for the SYNC OUT mode, the DUS is sent on the
OC-n interface towards the NE from which the DS1/E1 timing output is being derived. The Synchronized - Traceability Unknown (STU) message is sent on all other OC-n interfaces where sync messaging is provisioned. If the DS1/E1 output is generating AIS while the system is configured in this way, the message STU is transmitted on all OC-n interfaces.
TG3 with free running or holdover
When using the embedded TG3, if DMX is configured for free running or is in holdover mode, the Traceable Stratum 3 message is sent on all
OC-n interfaces for which sync messaging is enabled.
Line timing
When DMX is configured for line timing, the
DUS
message is sent on the OC-n interface towards the NE from which the timing is being derived. The message received on the OC-n interface is sent on all other OC-n interfaces where sync messaging is enabled.
Automatic synchronization reconfiguration
With automatic synchronization reconfiguration, the DMX shelves receive and compare the incoming sync messages on the OC-n interfaces available for line timing to select the highest quality synchronization reference available. If the received quality levels are the same on the references available for timing, the active line timing reference takes precedence. This feature guarantees the non-revertive operation of reconfiguration. In R4.0, DMX added a revertive option.
The existence of automatic synchronization reconfiguration does not affect OC-n line protection switching.
Hitless Timing and
Equipment Switching
(R7.0)
Hitless timing equipment switching enables switching from an active timing generator (TG) on one Main circuit pack to the TG on the other
Main circuit pack without incurring transmission hits on any of the
Main, Function Unit, or Growth circuit packs. This feature is only available on the VLF Main packs (LNW59). Low-speed, tributary
OLIUs that allow hitless timing switching include the following:
LNW45, LNW49, LNW55. DS1 & DS3 signals/cards are
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
5 - 8 7
Sync Messaging Feature Details and Options
System Planning and Engineering
asynchronous, and are not affected by a timing switch. Ethernet packs are also unaffected.
...........................................................................................................................................................................................................................................................
5 - 8 8
365-372-300
Issue 8.0, September 2006
System Planning and Engineering
Sync Messaging Examples
............................................................................................................................................................................................................................................................
Overview
In this section, some detailed examples are given to show specifically how the sync messages propagate through network and assist in the recovery from a fiber failure. Through these examples, one can extend the same concept to any other network that may include different topologies, number of sites, failure locations, and number of BITS clocks. Some examples are depicted in a linear configuration because the particular sync messaging concept is more easily conveyed in linear terms. Those concepts can be applied to DMX ring networks.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
5 - 8 9
Sync Messaging Examples
System Planning and Engineering
Derived DS1 with NO
Synchronization autoreconfiguration using externally timed ring
Part “a” of the figure below illustrates an externally timed access ring operating in its normal configuration. The DMX shelf at Site A is externally timed from a BITS clock referenced to a Primary Reference
Source (PRS). The remaining DMX shelves (Sites B, C, and D) are externally timed from a BITS referenced to a derived DS1 timing reference output. The STU message is sent to indicate where timing is traceable to an external BITS and where it is valid to be used.
Automatic synchronization reconfiguration is not an option for externally timed DMX shelves. Therefore, a change in the sync message will not cause an automatic synchronization reconfiguration.
In part “b”, a fiber has been cut between Sites A and B. Immediately,
DMX at site B changes the format of its derived DS1 to AIS. All other non-host nodes will track the holdover clock at Site B. Although no timing loops have been formed, the timing of all non-host nodes will differ from the host node by the accuracy of the holdover clock at Site
B.
Figure 5-22 External Timing with Derived DS1 Output,
Part A and B
PRS Traceable
Source a) Synchronization Reconfiguration
Example (Before Failure)
BITS
CLOCK b) Synchronization Reconfiguration
(After Failure)
PRS Traceable
Source
BITS
CLOCK
STU
DMX
STU
Site A
STU
STU
DMX
Site D Site B
DMX
STU
DMX
DMX
STU
Site A
STU
Site D Site B
DMX
STU
BITS
CLOCK
STU
Site C
DMX
STU
STU
BITS
CLOCK
BITS
CLOCK
GOOD
STU
STU
Site C
DMX
STU
STU
BITS
CLOCK
BITS
CLOCK
AIS
BITS
CLOCK
Holdover
Mode
Sync Flow
®
DMX = Metropolis DMX Access Multiplexer nc-dmx-074
...........................................................................................................................................................................................................................................................
5 - 9 0
365-372-300
Issue 8.0, September 2006
Sync Messaging Examples
System Planning and Engineering
NOTE:
The BITS clocks above are shown with only one input in order to demonstrate the effects of autoreconfiguration versus nonautoreconfiguration.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
5 - 9 1
Sync Messaging Examples
System Planning and Engineering
Synchronization autoreconfiguration in an access ring
Part “a” of the figure below illustrates an access ring operating in its normal configuration. The DMX shelf at the CO is externally timed, and each of the other DMX shelves are line timed in a counterclockwise direction. The STU message is sent to indicate where timing is traceable to an external BITS and where it is valid to be used.
The DUS message is sent on the interface that is being used as the line timing reference and, thus, where using that timing would create a timing loop. Sync messaging and automatic synchronization have both been enabled for this network.
In part “b”, a fiber has been cut between sites A and B. Immediately, the DMX shelf at site B enters holdover and sends out the Stratum 3 message to site C. The DMX shelf at site B cannot switch to line time from site C because it is receiving the
DUS
message on that interface.
Figure 5-23 Automatic Synchronization Reconfiguration,
Part A and B
a) Before Failure
PRS
Traceable
BITS b) Failure Occurs,
Site B Changes Message
PRS
Traceable
BITS
DMX
STU
STU
DU
DMX
Site A
STU
STU
STU
DMX
Site A
STU
STU
DU
Site B Site D
DU
Site C
DMX
STU
DMX
Stratum
3
DMX Site B Site D
DU
DU
Site C
DMX
STU
DMX
Sync Flow nc-dmx-173
...........................................................................................................................................................................................................................................................
5 - 9 2
365-372-300
Issue 8.0, September 2006
Sync Messaging Examples
System Planning and Engineering
In part c of the figure below, the DMX shelf at site C detects the incoming Traceable Stratum 3 message and sends the message to site
D. The DMX shelf at site C cannot switch to line timing from the other rotation because it is receiving the
DUS
message on that interface.
In part D of the figure below, the DMX shelf at site D detects the incoming Traceable Stratum 3 message. The STU message is a better quality message than the Traceable Stratum 3 message, so the DMX shelf at site D switches to line timing from site A. After the switch occurs, the
DUS
message is sent back to site A, and the STU message is retransmitted to site C.
Figure 5-24 Automatic Synchronization Reconfiguration,
Part C and D
c) Site C Changes Message
PRS
Traceable
BITS d) Site D Reconfigures
PRS
Traceable
BITS
?
STU
?
DMX
Site A
STU
STU
STU
S T3
DMX
Site B Site D
DUS
Site C
DUS
S
T3
DMX
ST3
DMX
S T3
Sync Flow
?
DMX
ST3
STU
DMX
?
ST3
Site A
DUS
STU
DUS
Site B Site D
DMX
S T3
DUS
Site C
STU
DMX
S T3 nc-dmx-172
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
5 - 9 3
Sync Messaging Examples
System Planning and Engineering
In part e of the figure below, the DMX shelf at site C detects the incoming STU message from site D. The STU message is a better quality message than the Traceable Stratum 3 message being received from site B, so the DMX shelf at site C switches to line time from site
D. After the switch occurs, the
DUS
message is sent back to site D, and the STU message is retransmitted to site B.
In part f of the figure below, the DMX shelf at site B detects the incoming STU message from site C. The STU message is a better quality message than the internal holdover capability, so the DMX shelf at site B switches to line time from site C. After the switch occurs, the
DUS
message is sent back to site C, and the STU message is forwarded to site A. When the failure clears, the synchronization remains in the new configuration unless it is manually switched back.
Figure 5-25 Automatic Synchronization Reconfiguration
Part E and F
e) Site C Reconfigures
PRS
Traceable
BITS f) Site B Reconfigures
PRS
Traceable
BITS
STU
DMX
ST3
Site A
DUS
STU
DUS
ST3
Sync Flow
DMX
STU
Site B Site D
Site C
STU
S T3
DMX
DUS
DMX
DUS
DMX
DUS
STU
STU
DUS
DMX
Site A
STU
DUS
Site B
STU
Site D
Site C
STU
DMX
DUS
DUS
DMX
DUS nc-dmx-171
...........................................................................................................................................................................................................................................................
5 - 9 4
365-372-300
Issue 8.0, September 2006
System Planning and Engineering
Frequently Asked Network Timing Distribution Questions
............................................................................................................................................................................................................................................................
Overview
The following are some frequently asked questions about network timing distribution.
1
How do I time DMX shelves in a central office environment?
Each DMX should be externally referenced to the BITS clock in the office. If a BITS clock is not available in the office, a traffic-carrying
DS1 from the local switch may be bridged (for example, using a bridging repeater) as the reference to the DMX. Line timing the DMX may also be used, but at least one DMX in the network must be externally timed.
2
Where do I use the DS1 timing output feature?
The primary application is for supplying one source for the BITS clock timing input reference. This allows the BITS clock to be slaved to a
BITS clock in another office that is, in turn, traceable to the primary reference source (PRS). Typically, the DMX supplying the DS1 timing output will, in turn, be externally timed by the BITS clock. The BITS clock should only derive one of its timing reference inputs from a particular network. Its other reference should be derived from another network to assure that it does not enter holdover mode.
If there is no BITS clock, the DS1 timing output can be used to time a switch or switch remote (if the switch remote is equipped for that option) directly— or even another DMX Multiplexer.
3
How do I prevent my BITS clock from using a DS1 timing output when a failure in the network results in this DS1 being timed from a SONET
NE in holdover?
SONET sync messaging informs the local DMX of this condition, and
AIS is inserted on the DS1 timing output.
4
What is the advantage of using the DS1 timing output instead of a multiplexed DS1 as the timing reference?
The DS1 timing output is derived from the optical line rate and is superior because:
• The DS1 is virtually jitter-free
• Sync messages guarantee the traceability of the timing
• Administration of traffic DS1s for timing is eliminated.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
5 - 9 5
Frequently Asked Network Timing Distribution
Questions
System Planning and Engineering
5
Can I ever use the DMX in the free running timing mode?
If a PRS traceable external reference is available, it is the recommended timing mode for any/all CO applications. The free running timing mode can be used but a slight increase in jitter will result. If one DMX is provisioned for free running, all other DMX NEs in the network must be line timed and SONET interfaces to other equipment are not allowed. The DS1 timing output should not be enabled with a free running network.
6
How do I provide timing to a central office host switch that does not have the option for an external reference?
A DS1 carried over SONET may contain significant jitter/wander and be unacceptable to the switch as a timing reference. If the central office has a BITS clock, the recommendation is to use the output from the
BITS clock into an unused DS1 traffic port on the switch. If the central office does not have a BITS clock, the recommendation is to use the
DS1 timing output from the DMX as the line timing reference into an unused DS1 traffic port on the switch.
7
Can a DS1 carried over SONET ever be used as a timing reference?
YES! In many applications there is no other choice. Most switch remotes, for instance, obtain their timing from a specific DS1 signal generated by their host switch, so these remotes must time from the
DS1 signal. In addition, DLC equipment, channel banks, and PBXs will not likely have external references and may be allowed to line time from a DS1 carried over SONET.
8
Are there any specific concerns when using a DS1 carried over SONET to time equipment such as a switch remote or DLC?
Yes. The major concern is to make sure all the equipment is synchronous. The DMX NEs should be synchronous to each other to prevent pointer adjustments. This can be accomplished by having one source DMX that is externally timed. The other DMX NEs in the network should be line timed, or they should be externally timed to a clock to which they provide a DS1 timing output. The DMX NEs should also be synchronous to the switch to prevent excessive mapping jitter. This can be done by synchronizing the host switch to the BITS clock used to reference the DMX.
...........................................................................................................................................................................................................................................................
5 - 9 6
365-372-300
Issue 8.0, September 2006
Frequently Asked Network Timing Distribution
Questions
System Planning and Engineering
9
Will I have any problems providing timing to a customer that has a high quality PBX or switch?
If the network is completely synchronous, as described in the previous answer, there should be no problems. If the PBX is sensitive to the jitter produced, even under the synchronous conditions, the DS1 timing output of DMX may be required to be used as a timing reference to this equipment.
10
Why does Telcordia say that DS1s carried over SONET should not be used for timing?
Telcordia has provided this recommendation because there are several limitations. Telcordia says that DS1s carried over SONET must be used in applications such as switch remotes and will be acceptable, provided pointer adjustments are not created.
11
Can pointer adjustments be prevented?
Neither random nor periodic pointer adjustments will occur if the DMX shelf is provisioned for line timing.
12
How do I time DMX at a remote site?
Line time.
13
How many DMX NEs can I chain together in an add/drop configuration before the timing becomes degraded?
The Stratum level traceability of the nth node in an add/drop chain is the same as that in the first node. Also, while timing jitter will theoretically increase as the number of nodes is increased, the high quality timing recovery and filtering on the DMX allows add/drop chains to be extended to any practical network limit without detectable increases in jitter levels. In practice, the only effects on timing at the nth node will occur whenever high-speed protection switches occur in any of the previous n-1 nodes. These effects should be rare.
14
How do I time a DMX ring network?
An interoffice ring should have each node externally timed if BITS clocks are available. All other rings should have one node externally timed (two in some dual homing architectures) and the rest of the nodes line timed. Synchronization reconfiguration is automatic.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
5 - 9 7
Frequently Asked Network Timing Distribution
Questions
System Planning and Engineering
15
Why are there more issues related to timing with SONET equipment than there are with asynchronous equipment?
SONET equipment was designed to work ideally in a synchronous network. When the network is not synchronous, mechanisms such as pointer processing and bit-stuffing must be used and jitter/wander increases.
16
Can DS3 signals be used to carry DS1 timing signals without the worry of having the network synchronous?
Yes, although this option is more expensive.
17
What are the limitations on automatic synchronization reconfiguration?
Automatic synchronization reconfiguration is only available when the
DMX is provisioned for line timing mode. This allows the timing direction of an OC-n (OC-3/12/48/192) ring network to change automatically in response to a failure. OC-3 line timing is only available beginning in R7.0, through support of tributary line timing
(OC-12/48 tributary optical line can also be used). When the DMX is provisioned for external timing, automatic synchronization reconfiguration is not available. When an OC-n fault is detected in the timing direction, AIS is inserted on the derived DS1s which forces the
BITS to switch to another good timing source or into holdover preventing timing loops.
18
How do I synchronize a BITS clock and maintain automatic synchronization reconfiguration on a DMX ring?
Provision all but the host node (node with co-located PRS) for line timing. Provide each non-host BITS clock with a pair of derived DS1s.
The DMX will detect faults and provide the BITS clocks with good inputs if available. Timing loops will be prevented. The host node should be set for external timing and get its timing from an externally timed BITS clock. To prevent a timing loop, the host BITS clock should get its timing from a PRS traceable source. The non-host nodes should not be timed from the co-located BITS clock since this would disable the automatic synchronization reconfiguration feature.
...........................................................................................................................................................................................................................................................
5 - 9 8
365-372-300
Issue 8.0, September 2006
6 Operations, Administration,
Maintenance, and Provisioning
Overview
............................................................................................................................................................................................................................................................
Purpose
This chapter describes the operations, administration, maintenance, and provisioning (OAM&P) functions for the DMX Access Multiplexer.
Contents
The following sections are included in this chapter:
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
6 - 1
Operations, Administration, Maintenance, and Provisioning
Maintenance
Overview
............................................................................................................................................................................................................................................................
Purpose
This section describes the maintenance philosophy of the DMX Access
Multiplexer.
Contents
The following maintenance topics are discussed in this section:
Lucent Operations Interworking
Multi-Vendor Operations Interworking
Data Communications Channel (DCC)
Fault Detection, Isolation, and Reporting
...........................................................................................................................................................................................................................................................
6 - 2
365-372-300
Issue 8.0 September 2006
Operations, Administration, Maintenance, and Provisioning
Three-tiered Operations
............................................................................................................................................................................................................................................................
Overview
The figure below, shows the three-tiered operations procedures for
DMX. The DMX operations procedures are built on three levels of system information and control, spanning operations needs from summary-level status to detailed reporting.
Figure 6-1 Three-Tiered Operations
TIER 3:
OS Access
IAO LAN (TCP/IP or OSI)
Operations Center
TIER 1:
®
Metropolis DMX
SYSCTL LEDs and Pushbuttons
Circuit Pack Fault and Active LEDs
Routine Operations and Maintenance
Fault Verification
Circuit Pack Replacement
Default Provisioning
TIER 2: PC-CIT
Serial or
IAO LAN
Enhanced Maintenance and Provisioning
Detailed Reports
Manual Controls
Provisioning
Security
Software DoWnload/
Database Backup and Restoration
Remote Maintenance and Provisioning
Alarm Surveillance
Performance Monitoring
Automated Service
Provisioning
Remote Control
Security
Software DoWnload/
Database Backup and Restoration nc-dmx-016
SYSCTL faceplate
(Operations Tier 1)
Office alarms are provided by a set of discrete relays that control office audible and visual alarms. Separate relays handle critical (CR), major
(MJ), and minor (MN) alarms, although the CR and MJ alarms can be wire ORed and reported as office major, if desired.
The light-emitting diodes (LEDs) and push buttons on the SYSCTL faceplate allow routine tasks to be performed without a PC-CIT or any test equipment. The SYSCTL faceplate LEDs provide system-level alarm and status information for the local NEs and a summary for all remote NEs in the alarm group. The circuit pack faceplate FAULT
LEDs allow fast and easy fault isolation to a particular circuit pack.
The SYSCTL faceplate LEDs default to show local system information. The highest active alarm level is shown by the red LEDs for CR and MJ alarms. Yellow LEDs are shown for MN alarms. An
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
6 - 3
Three-tiered Operations
Operations, Administration, Maintenance, and Provisioning
ACO button is used to activate the alarm cutoff function. When activated, the LED is on. The ACO button also initiates an LED test when the button is depressed and held. A green PWR ON LED shows that the power is on and the terminal is receiving a -48V source. Three yellow status LEDs show abnormal (ABN) conditions, near-end activity (NE), and far-end activity (FE). The yellow ABN LED is lighted when a temporary condition, potentially affecting transmission, exists. For example, this condition could be a manual protection switch or lockout, loopback, or system test in progress.
The Update/Initialize (UPD/INIT) button addresses the local system.
The recessed UPD/INIT button serves several functions during installation and circuit pack replacement. During the first 10 seconds after powering up the SYSCTL circuit pack, depressing this button initializes the nonvolatile memory with provisioning and state information. Secondly, after removing a circuit pack, optical module, or low-speed input, depressing this button updates the system equipment list to show the slot, socket, or signal is now unequipped.
The SYSCTL faceplate’s remote display functions serve the singleended maintenance needs of access transport applications. When any alarm or status condition exists at a remote DMX shelf in the same alarm group, the FE LED on the faceplate is lit.
...........................................................................................................................................................................................................................................................
6 - 4
365-372-300
Issue 8.0 September 2006
Three-tiered Operations
LED/Push-button
Active
FAULT
CR
MJ
MN
ABN
FE
NE
ACO
ACO/TEST
SEL
UPD/INIT
Operations, Administration, Maintenance, and Provisioning
The table below details the various LEDs and push-button switches and describes their functions.
Table 6-1 SYSCTL Faceplate Indicators and Functions
Indicator name
Active
Fault
Critical
Major
Minor
Abnormal
Far-End Activity
Near-End Activity
Alarm Cut-Off
Alarm Cut-Off/Test
Select
Update/Initialize
Function
Indicates the SYSCTL is Active.
Indicates isolated circuit pack failure.
Indicates critical alarm for local system.
Indicates major alarm for local system.
Indicates minor alarm for local system.
Indicates temporary transmission-affecting condition.
Indicates remote alarm or status condition.
Indicates local alarm or status condition.
Activates alarm cut-off (will also display software version information when depressed for 3 seconds).
Performs LED tests.
When SEL and UPD/INIT button are held down together, you get a 4 segment square (::).
Updates the local system.
Circuit pack LEDs
To supplement the SYSCTL faceplate’s system-level view, each circuit pack provides a red FAULT LED on its faceplate. A lighted FAULT
LED shows that the DMX has isolated a failure to that circuit pack. On transmission circuit packs, a flashing FAULT LED shows that an incoming signal to that circuit pack has failed.
Important!
All circuit packs that use PTM optics have per-port
LEDs. The LNW37 can be used with pre-R4 software, but in that case the per-port LEDs are unused, and the paragraph above applies). The board FAULT LED on the PTM packs is lit solid when there's a board failure, and blinks if there's a port or socket failure. The per-port LED is lit solid if there's a socket failure, and blinks if there's an incoming port (signal) failure.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
6 - 5
Three-tiered Operations
Operations, Administration, Maintenance, and Provisioning
Local craft interfaces
(Operations Tier 2)
The local craft interfaces include the PC-CIT, which may be utilized in a variety of ways.
DMX has two serial ports for PC-CIT access, one in the front one and one at the rear of the shelf.
TL1 is supported for both serial ports, but software download is supported via the front serial port only.
DMX also has two LAN ports for PC-CIT (and/or OS) access, one in the front and one in the rear. Both TL1 over OSI and TL1 over TCP/IP are supported via these two LAN ports. Software download via FTAM or FTP and FTTD are also supported.
PC-CIT (TL1 over TCP/IP)
The PC-CIT is a small CIT interface that provides a flexible TL1 command instructor. The PC-CIT connects to a DMX using either the front or rear serial ports, the front IAO LAN port, or the rear IAO LAN port. The PC-CIT supports TCP/IP (or OSI) through both the front and rear IAO LAN interfaces.
The PC-CIT is used for report generation, as well as command and system response. Access to the system is provided via serial or IAO
LAN interfaces.
Operations System (OS)
TL1/LAN interfaces
(Operations Tier 3)
The third operations tier consists of OS access. DMX OS interfaces are
IAO LAN ports.
TL1
The TL1 message-based OS interface provides remote OS access, as well as detailed reporting and control capabilities. The interface uses standard TL1 and needs no mediation device (i.e., the interface can be connected directly). The remote user could be an OS or a user at a terminal. Lucent Technologies is involved in an active OSMINE process to ensure compatibility of DMX NEs with Telcordia OSs.
The DMX supports TL1 alarm surveillance and performance monitoring with OSs such as Telcordia’s Network Monitoring and
Analysis (NMA). The DMX supports service provisioning with memory administration OSs such as Lucent’s Navis OMS or
Telcordia’s TEMS. The DMX also supports remote recovery and control functions, installation provisioning, and security over the TL1 link. The TL1 message set used has been updated to offer full remote reporting capabilities.
...........................................................................................................................................................................................................................................................
6 - 6
365-372-300
Issue 8.0 September 2006
Three-tiered Operations
Operations, Administration, Maintenance, and Provisioning
The OS can use more than one NE as a GNE to provide redundancy and/or to distribute TL1 message volume. The TL1 GNE serves as a single interface to the OS for the NEs in the same subnetwork. The TL1
GNE receives operations information from all the NEs through the
DCC and reports this information, as well as its own information, to the
OS. The operations information is in the form of TL1 messages.
Through the GNE, the OS can send TL1 commands to any NE in the subnetwork. Lucent’s Navis OMS, as well as other-vendor NEs that adhere to GR-253-CORE, can serve as the TL1 GNE for the DMX.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
6 - 7
Three-tiered Operations
Operations, Administration, Maintenance, and Provisioning
Front IAO LAN
The front IAO LAN interface provides a connection to the PC-CIT and supports OSI or TCP/IP communications. The front IAO LAN is located on the faceplate of the SYSCTL circuit pack.
Rear IAO LAN
The primary purpose of the rear IAO LAN port is to provide remote OS access such as OS TL1 access over TCP/IP Gateway. It also supports a faster software download from Navis
®
EMS (or any FTP server) using file transfer protocol (FTP) to Lucent DMX systems when software is being upgraded (both the rear and front IAO LAN ports support this functionality). This rear IAO LAN port can also be used for PC-CIT
OSI-based interfaces and TCP/IP support.
The figure below shows how DMX works with the various operations interfaces.
Figure 6-2 Operations Interfaces
Local Operations
Interfaces (Front)
PC-CIT
TL1/EIA-232D Asynch
TL1/TCP-IP or TL1/OSI/
IAOLAN
Remote NE
TL1/OSI/IP SONET DCC
LEDs
Buttons
Metropolis
®
DMX
SYSCTL
(Rear)
TL1/TCP-IP or TL1/OSI/
IAOLAN*
Tl1
Rear Serial Port
(Modem - CIT)
Office Alar ms
Miscellaneous Discretes
Remote
NMS/EMS
TL1 over OSI supports TARP
Protocol per GR-253-CORE
* LAN could also interface with LAN on another NE nc-dmx-013
...........................................................................................................................................................................................................................................................
6 - 8
365-372-300
Issue 8.0 September 2006
Operations, Administration, Maintenance, and Provisioning
IAO LAN Ports (detail)
............................................................................................................................................................................................................................................................
Overview
DMX supports a front and rear IAO LAN port. Each IAO LAN port operates independently (DMX does not support an internal IAO LAN hub). The front IAO LAN port is recommended for convenient, temporary local WaveStar
®
CIT access. When, for example, the
WaveStar
®
CIT is directly connected to either IAO LAN port, a LAN crossover cable is required (to connect the transmit wire-pair at one end to the receive wire-pair at the other end, and vice versa).
The rear IAO LAN port is recommended for permanent local
WaveStar
®
CIT access and all remote WaveStar
®
CIT access via TCP/
IP as well as for OS access. DMX’s rear IAO LAN port is typically expected to be connected to an Ethernet LAN hub in CO applications, but unused at remote sites.
The DMX IAO LAN ports support 10/100BaseT Ethernet (per
Telcordia Technologies GR-253, ANSI/IEEE 802.2 and 802.3, and ISO
8802.2 and 8802.3) over four-wire twisted pair using an RJ-45 connector. Each IAO LAN port automatically adapts its rate to 10 Mb/s or 100 Mb/s to match the capability of the other nodes on the same IAO
LAN, with 10 Mb/s as the default rate.
OSI on the IAO LAN
When the OSI protocol stack is used on an IAO LAN port, the term
“OSI LAN” is sometimes used. The OSI LAN is effectively an extension of the DCC. All remote operations supported over the DCC are also supported over the OSI LAN. The term “DCC connectivity” is used throughout this document to mean DCC and/or OSI LAN connectivity.
OSI communications on the IAO LAN port can be enabled or disabled.
Beginning in R3.1.1, by default, OSI is enabled on the front IAO LAN port, but disabled on the rear IAO LAN port.
TCP/IP on the IAO LAN
The IAO LAN ports also support the TCP/IP protocol stack. TCP/IP communications on the IAO LAN ports can be enabled or disabled. By default, TCP/IP is disabled on the IAO LAN ports.
When the TCP/IP protocol stack is used on an IAO LAN port, the term
“TCP/IP LAN” is sometimes used.
DMX supports TL1 over TCP/IP for the IAO LAN. As a TL1 responder, DMX TCP/IP GNE accepts incoming TL1 connections to the following TCP ports with corresponding TL1 encodings.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
6 - 9
IAO LAN Ports
Operations, Administration, Maintenance, and Provisioning
Port 3081: Length-Value Encoding. With length-value encoding, each TL1 message is encapsulated into the TCP data stream as follows:
• Version number (1 byte, value set to 3)
• Reserved (1 byte, value set to 0)
• Length (2 bytes, value set to length in bytes of TL1 message + 4)
• TL1 Message (variable length
The length-value encoding is the preferred encoding for machine machine interactions.
Port 3082: Raw Encoding. Each raw encoded TL1 message is encapsulated into the TCP data stream of length 1 - 4096 bytes. The
TL1 message must be parsed to find the boundary between successive
TL1 messages (see Telcordia GR-831 CORE for the syntax of TL1 messages).
Port 3083: Telnet Encoding. The telnet encoding is a variation on the raw encoding. It encapsulates TL1 messages in a TCP stream and uses
Telnet for transmitting text over TCP/IP.
...........................................................................................................................................................................................................................................................
6 - 1 0
365-372-300
Issue 8.0 September 2006
IAO LAN Ports
Operations, Administration, Maintenance, and Provisioning
OSI or TCP/IP on the same
IAO LAN
It is generally recommended that each IAO LAN port be used for OSI or TCP/IP, but not both protocols simultaneously on the same IAO
LAN port.
The figure below provides examples of common applications using the
IAO LAN ports.
Figure 6-3 IAO LAN Port Applications
Operations Center
WaveStar
®
CIT
OSs
10/100 BaseT
Ethernet
LAN Hub
Remote Location
WaveStar
®
CIT
CO
WaveStar
®
CIT
Front IAO
LAN Port
WaveStar
®
CIT
OSI
Metropolis
®
DMX
SYSCTL
OC-48
UPSR with
DCC
TCP/IP
Rear IAO
LAN Port
10/100 BaseT
Ethernet
LAN Hub
IP WAN
Metropolis
®
DMX
SYSCTL
OSI
Front IAO
LAN Port
Remote Site
WaveStar
®
CIT nc-dmx-003
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
6 - 1 1
IAO LAN Ports
Operations, Administration, Maintenance, and Provisioning
IAO LAN compatibility
The following table documents DMX IAO LAN communications compatibility with other products and the applicable OSI and/or TCP/
IP protocol stacks. (WaveStar
®
CIT and OS access applications compatibility via the IAO LAN is covered separately later.)
Table 6-2 IAO LAN Compatibility
Product
DMX
DMXplore
DMXtend
DDM-2000 OC-3
DDM-2000 OC-12
FiberReach
FT-2000 ADR
WaveStar
®
TDM 2.5G/10G (2-Fiber)
WaveStar
®
BandWidth Manager
Lambda Unite
WaveStar
®
CIT
Navis
®
Optical Element Management
System
(formerly SNMS)
Navis
®
Ethernet Management System
DMX
OSI
yes
-
yes yes yes yes yes yes yes yes yes yes yes yes
TCP/IP
yes yes
-
yes
-
yes yes yes yes
...........................................................................................................................................................................................................................................................
6 - 1 2
365-372-300
Issue 8.0 September 2006
Operations, Administration, Maintenance, and Provisioning
Operations Philosophy
............................................................................................................................................................................................................................................................
Overview
The DMX has incorporated an operations philosophy that is optimized for operations in the access transport environment. This allows operation and maintenance of remote NEs from a single location.
Similarly, a technician working at a remote site can gain access to other
NEs. In addition, OSs are available to allow operation of the DMX NEs from a centralized operations center.
The DMX uses the SONET data communications channel (DCC) to provide remote PC-CIT access, remote CO alarms, remote alarm reports, and remote OS access. The terms remote operations, singleended operations (SEO), and Operations Interworking (OI) are synonymous.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
6 - 1 3
Operations Philosophy
Operations, Administration, Maintenance, and Provisioning
SEO capability
The figure below shows the SEO capability that provides remote access to all DMX systems in a subnetwork from a single DMX location. This minimizes the need for technician travel because most maintenance, provisioning, and administration can be performed on all NEs with
DCC connectivity by accessing any one NE. The SEO capability can be disabled between NEs to create maintenance boundaries (for example, interoffice applications) or for security reasons.
Figure 6-4 Remote Operations Philosophy
Remote
Operation
Center
IAO LAN,
TCP/IP LAN, or
TL1/X.25
Single Span
Single-Ended Operations
Serial PC/CIT or
IAOLAN
OC-48
CIT
SYSCTL
OC-48 OC-48
®
Metropolis DMX
®
Metropolis DMX
OC-48
Legend:
SONET
DCC enabled nc-dmx-014
...........................................................................................................................................................................................................................................................
6 - 1 4
365-372-300
Issue 8.0 September 2006
Operations, Administration, Maintenance, and Provisioning
Lucent Operations Interworking
............................................................................................................................................................................................................................................................
Overview
Operations interworking (OI) provides the capability to access, operate, administer, maintain, and provision remote Lucent NEs from any
Lucent NE with DCC connectivity in a network or from a centralized
OS.
OI support
Lucent OI is available among NEs that are connected through the
SONET DCC or IAO LAN. With this feature, users can perform
OAM&P activities on a centralized basis, saving travel time and money.
OI features including the following:
• Remote OS access via TL1 over TCP/IP (or OSI) or TL1
• Remote OS access via IP over DCC
• Remote PC-CIT access
• Remote NE status
• Remote software download and copy
• Remote time and date synchronization
For more information on OI, refer to Lucent Technologies WaveStar
Product Family Operations Interworking Guide, 365-372-303.
The following table summarizes DMX OI compatibility with the products and releases specified in the previous table.
Table 6-3 DMX OI Compatibility Summary
Product
DMX
DMXplore
DMXtend
DDM-2000 OC-3
DCC IAO
LAN
WaveStar
®
CIT
Access
OS Access from
DMX
DMX tl1-gne
DMX tl1-rne
yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes -
yes
-
Remote
Software
Downloa d
yes yes yes yes
.
Auto.
Time/
Date
Sync
yes yes yes yes
Remot e
NE
Status
yes yes yes yes
DDM-2000 OC-12
FiberReach yes yes yes yes yes yes yes -
yes yes yes yes
yes
FT-2000 ADR yes yes yes -
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
6 - 1 5
Lucent Operations Interworking
Operations, Administration, Maintenance, and Provisioning
Product DCC IAO
LAN
WaveStar
®
CIT
Access
OS Access from
DMX
DMX tl1-gne
DMX tl1-rne
WaveStar
®
TDM
2.5G/10G (2-Fiber)
WaveStar
®
BandWidth
Manager yes yes yes yes yes yes yes
yes yes yes
-
yes yes
-
Lambda Unite yes yes
Ciena
®
Core Director yes -
Navis
®
Optical
Element Management
System
(formerly SNMS)
Navis
®
Ethernet
Management System
-
yes yes
NMA
Transport (TEMS)
-
yes yes
-
-
-
yes yes yes yes yes yes yes yes
Remote
Software
Downloa d
.
Auto.
Time/
Date
Sync
Remot e
NE
Status
-
-
-
-
-
-
-
-
-
-
-
yes yes
-
-
-
-
-
-
-
-
-
-
Alarm groups
An alarm group is a set of NEs that share status information between themselves, such as alarms, LEDs, and ACO status. The set of remote
NEs that an NE can exchange status information which is determined by the value of the local alarm group parameter. This parameter is provisioned at each local NE and specifies whether that local NE does or does not exchange remote NE status with other Lucent NEs in the same SONET subnetwork. In DMX, all NEs are defaulted into the same alarm group (number 255).
Alarm groups can be nodes in a ring, nodes of a linear extension, or any other logical grouping such as a maintenance group or geographical group. For example, 24 NEs could be provisioned into three alarm groups with eight NEs that share a community of interest such as the same OC-3 low-speed optical interface.
All members of the same alarm group share NE status information but do not share information with other alarm groups.
Alarm group functions
Depending on provisioning, a member of an alarm group can:
...........................................................................................................................................................................................................................................................
6 - 1 6
365-372-300
Issue 8.0 September 2006
Lucent Operations Interworking
Operations, Administration, Maintenance, and Provisioning
• Know the alarm/status of all members of the same alarm group and, if the NE is at the CO, activate audible office alarms for the alarm group.
• List a report of the summary alarm or status condition of other
NEs in the group.
• Display composites of the highest alarm level among other member NEs in the same alarm group.
Alarm Gateway Network
Element (AGNE)
Members of an alarm group exchange information through one or more alarm gateway NEs (AGNEs) that are defined in the same alarm group.
All DMX NEs use the DCC to receive and report alarm and status information to the AGNE(s). The AGNE rebroadcasts all alarm and status information from one NE to all the other NEs in the same alarm group.
This information is used to activate remote far-end summary alarm reports and remote office alarms for each NE in the alarm group. At least one NE in each alarm group must be provisioned as the AGNE.
An additional AGNE can be provisioned for redundancy, but it is recommended that only one AGNE be provisioned for each alarm group. Considerations for choosing an NE as an AGNE include being central to the group to make communications links easily accessible for maintenance purposes.
The AGNE and TL1 GNE should be separate NEs. Furthermore, the
AGNE is a “collection point” and does not have to be a NE in a CO.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
6 - 1 7
Operations, Administration, Maintenance, and Provisioning
Multi-Vendor Operations Interworking
............................................................................................................................................................................................................................................................
TARP
To support multi-vendor OI, the DMX supports Target ID Address
Resolution Protocol (TARP).
TARP provides NSAP-TID translations and is the established multivendor standard for SONET NEs that support TL1 OS interfaces. DMX supports the TARP Data Cache (TDC) function to reduce the frequency of TARP propagation throughout the subnetwork and to improve performance.
Compatibility
DMX is developed to be compatible with any other-vendor NEs that support TARP, OSI, IAO LAN, and TL1 as specified in Telcordia
Technologies GR-253. In addition, DMX’s TARP Manual Adjacency feature enables it to operate in networks that include CMISE-based
NEs which may not support TARP propagation. DMX supports user provisioning of several OSI parameters to allow users to adjust their operations network, if necessary. For example, to support Level 2
Routing in large networks, DMX supports user provisioning of NSAP area addresses and Level 2 Intermediate System (IS) functionality.
DMX’s compatibility with other-vendor NEs may be tested by customers or independent third parties such as Telcordia Technologies.
...........................................................................................................................................................................................................................................................
6 - 1 8
365-372-300
Issue 8.0 September 2006
Operations, Administration, Maintenance, and Provisioning
Data Communications Channel (DCC)
............................................................................................................................................................................................................................................................
Provisioning the DCC
To support remote operations over the DCC embedded in the SONET section overhead of the optical signal, the DCC itself must be provisioned as indicated in the following paragraphs.
DCC enable/disable
By default, the DCC is enabled on all optical ports. DCC communications can be enabled or disabled on each port independently.
DCC protection mode
The DCC protection mode is determined by the transmission protection mode assigned to each optical port (per the application parameter). The protection mode can be linear (1+1) identical, or distinct (UPSR).
Linear (1+1) identical is the default for the low-speed optical ports.
Release 7.0 also supports 15 low-speed OC-48 BLSRs.
In systems equipped with Release 2.0 or earlier software, the highspeed optical ports are always distinct (UPSR) and are not provisionable.
In systems equipped with Release 2.1 software, the OC-48 high-speed optical ports may be provisioned for UPSR or BLSR applications. The
OC-192 high-speed ports are autoprovisioned for UPSR applications only.
In systems equipped with Release 3.0 and later software, the OC-48 high-speed optical ports may be provisioned for UPSR, BLSR, or 1+1 applications. The OC-192 high-speed ports may be provisioned for
UPSR (R2.1), BLSR (R3.0), or 1+1 (R4.0) applications.
In systems equipped with Release 3.1 and later software, the OC-12 high-speed optical ports may be provisioned for UPSR or 1+1 applications.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
6 - 1 9
Data Communications Channel (DCC)
Operations, Administration, Maintenance, and Provisioning
The following table summarizes the DCC protection modes.
Table 6-4 DCC Protection Modes
1
Optical Port
Protection Mode
Shelf Slots
OC-12/OC-48/OC-192
UPSR
OC-48/OC-192 BLSR
OC-12/OC-48/OC-192
Linear (1+1)
OC-12/OC-48/OC-192
Bidirectional (1+1)
OC-48 UPSR
OC-48 BLSR
OC-48 Linear (1+1)
OC-48 Bidirectional (1+1)
OC-48 0x1
2
OC-48 0x1Sn
2
OC-12 UPSR
OC-12 Linear (1+1)
OC-12 Bidirectional (1+1)
OC-12 0x1
2
OC-12 0x1Sn
2
OC-3 UPSR
OC-3 Linear (1+1)
OC-3 Bidirectional (1+1)
OC-3 0x1
2
OC-3 0x1Sn
2
High-speed Main slots
Low-speed Function and Growth slots
15 pair
20 pairs
20 pairs
20 pairs
20 pairs
40 pairs
40 pairs
40 pairs
40 pairs
40 pairs
80 pairs
80 pairs
80 pairs
80 pairs
Max. Number
Simultaneous
Optical Ports
(see note)
1 pair (2 for
OC-192)
1 pair (2 for
OC-192)
1 pair (2 for
OC-192)
1 pair (2 for
OC-192)
20 pairs
Max. Number
Simultaneous
Section DCCs
1 pair (2 for OC-
192)
1 pair (2 for OC-
192)
1 (2 for OC-192)
1 (2 for OC-192)
40
40
40
40
80 pairs
80
80
80
20 pairs
15 pair
20
20
20
20
40 pairs
...........................................................................................................................................................................................................................................................
6 - 2 0
365-372-300
Issue 8.0 September 2006
Data Communications Channel (DCC)
Operations, Administration, Maintenance, and Provisioning
Optical Port
Protection Mode
Shelf Slots Max. Number
Simultaneous
Optical Ports
(see note)
Max. Number
Simultaneous
Section DCCs
Notes:
1. In this table, each optical port counted includes both a transmit and receive fiber.
2. 0x1 mode is supported in R7.0 (and going forward) with the use of the VLF Main packs
(LNW59). 0x1Sn is supported in Releases prior to R7.0 and in R7.0 when non-VLF Mains are used. 0x1 is only available on low-speed/tributary packs, not high-speed network interface packs.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
6 - 2 1
Data Communications Channel (DCC)
Operations, Administration, Maintenance, and Provisioning
User side and network side
The operation of each DCC span also depends on one end of the span being designated the “User” side and the other end being designated the
“Network” side. The DCC User/Network side assignments are provisionable.
By default, the high-speed port dcc-m1-1 is designated the “User” side and dcc-m2-1 is designated the “Network” Side. If each DMX on a high-speed ring application is connected to its neighbor with a fiberpair between ports main-1 and main-2, the default DCC User side/
Network side assignments are sufficient.
The figure below shows an example of the User and Network side designations for DMXs on a high-speed UPSR or BLSR.
Figure 6-5 User/Network Side Designation on a UPSR/BLSR
M1
User Side
Metropolis
®
DMX
OC-48 OLIU
M2
Network Side
M2
Network Side
Metropolis
®
DMX
OC-48 OLIU
M1
User Side
UPSR/BLSR
M1
User Side
Metropolis
®
DMX
OC-48 OLIU
M2
Network Side nc-dmx-188
...........................................................................................................................................................................................................................................................
6 - 2 2
365-372-300
Issue 8.0 September 2006
Data Communications Channel (DCC)
Operations, Administration, Maintenance, and Provisioning
By default, low-speed linear (1+1) DCC is designated “Network” side but low-speed UPSR/BLSR DCC designations alternate between each
Function Slot and Growth Slot, for example, dcc-a1-1 is designated
“Network” side and dcc-a2-1 is designated “User” Side. If each DMX on a low-speed UPSR is connected to its neighbor with a fiber-pair between ports fn-a-1-1 and fn-a-2-1 (for example), the default DCC
User side/Network side assignments are sufficient. For 0x1Sn, the active side of the topology is set to “Network”. For 0x1, both sides of the topology are set to “Network”.
The figure below shows an example of the User and Network side designations for DMXs on a low-speed UPSR with DDM-2000.
Figure 6-6 User/Network Side Designation on an OC-3/12 UPSR with DDM-2000
Network
Side
Metropolis
®
DMX
Metropolis
®
DMX
User Side
OC-3 or OC-12
UPSR with DCC
User Side
Network Side
Network Side
User
Side
DDM-2000 nc-dmx-002
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
6 - 2 3
Data Communications Channel (DCC)
Operations, Administration, Maintenance, and Provisioning
The figure below shows an example of the User and Network side designations for DMXs on a low-speed OC-48 BLSR.
Figure 6-7 User/Network Side Designation on a Low Speed OC-
48 BLSR
Metropolis
®
DMX
Network
Side
Network
Side
User
Side
User Side
OC-48 BLSR
Network
Side
User
Side
Metropolis
®
DMX
Metropolis
®
DMX nc-dmx-269
...........................................................................................................................................................................................................................................................
6 - 2 4
365-372-300
Issue 8.0 September 2006
Data Communications Channel (DCC)
Operations, Administration, Maintenance, and Provisioning
DCC compatibility
Product
DMX
DMXplore
DMX supports the optical interfaces with DCC communications compatibility as shown in the following table. DMX supports Section
DCC running the OSI protocol stack and IP. The “1+1” entries represent linear and bidirectional (1+1) protected DCC compatibility.
Optical Interfaces
Supported
High-Speed
Low-Speed
High-Speed
Table 6-5 DCC Compatibility
OC-192
OC-48
OC-12
OC-48
OC-12
OC-3
OC-3
DMX
High-Speed Main Slots
OC-192 OC-48 OC-12 OC-48 OC-12 OC-3
UPSR/
BLSR/
1+1
UPSR/
BLSR/
1+1
UPSR/
BLSR/
1+1
UPSR/
1+1
UPSR/
1+1
Low-Speed Function and Growth Slots
UPSR/
BLSR/
1+1/
0x1Sn/
0x1
UPSR/
BLSR/
1+1/
0x1Sn/
0x1
UPSR
1+1/
0x1Sn/
0x1
UPSR/
1+1/
0x1Sn/
0x1
UPSR/
1+1/
0x1Sn/
0x1
UPSR/
1+1
DMXtend High-Speed OC-12
UPSR/
1+1
UPSR/
1+1/
0x1Sn/
0x1
OC-3 UPSR
1+1/
0x1Sn/
0x1
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
6 - 2 5
Data Communications Channel (DCC)
Operations, Administration, Maintenance, and Provisioning
Product
DDM-2000
OC-3
DDM-2000
OC-12
FiberReach
FT-2000 ADR
WaveStar
®
TDM
2.5G/10G (2-
Fiber)
Optical Interfaces
Supported
High-Speed
Low-Speed
OC-12
OC-3
OC-3
High-Speed OC-12
Low-Speed OC-3
High-Speed OC-12
OC-3
High-Speed OC-48
Low-Speed
High-Speed OC-48
Low-Speed
OC-12
OC-3
OC-12
OC-3
DMX
High-Speed Main Slots Low-Speed Function and Growth Slots
OC-192 OC-48 OC-12 OC-48 OC-12 OC-3
UPSR
UPSR/
0x1Sn/
0x1
UPSR/
0x1Sn/
0x1
1+1/
0x1Sn/
0x1
UPSR
UPSR/
0x1Sn/
0x1
1+1/
0x1Sn/
0x1
UPSR
UPSR/
0x1Sn/
0x1
UPSR/
0x1Sn/
0x1
BLSR
BLSR/
0x1Sn/
0x1
1+1
1+1/
0x1Sn/
0x1
1+1/
0x1Sn/
0x1
UPSR/
BLSR
UPSR/
BLSR/
1+1/
0x1Sn/
0x1
UPSR
1+1
UPSR
1+1/
0x1Sn/
0x1
1+1/
0x1Sn/
0x1
...........................................................................................................................................................................................................................................................
6 - 2 6
365-372-300
Issue 8.0 September 2006
Data Communications Channel (DCC)
Operations, Administration, Maintenance, and Provisioning
Product
WaveStar
®
BandWidth
Manager,
Release 4.0
Optical Interfaces
Supported
High-Speed
Low-Speed
OC-48
OC-12
OC-3
DMX
High-Speed Main Slots Low-Speed Function and Growth Slots
OC-192 OC-48 OC-12 OC-48 OC-12 OC-3
UPSR/
BLSR
UPSR/
BLSR/
1+1/
0x1Sn/
0x1
UPSR/
1+1
UPSR/
1+1/
0x1Sn/
0x1
1+1/
0x1Sn/
0x1
Lambda Unite High-Speed OC-192 UPSR/
BLSR/
1+1
OC-48
UPSR/
BLSR
UPSR/
BLSR/
0x1Sn/
0x1
Low-Speed OC-12
UPSR/
1+1
UPSR/
1+1/
0x1Sn/
0x1
OC-3 1+1/
0x1Sn/
0x1
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
6 - 2 7
Operations, Administration, Maintenance, and Provisioning
Software Download (Generic)
............................................................................................................................................................................................................................................................
Overview
DMX supports local and remote software downloads.
For complete coverage of DMX’s software download features, refer to the
Metropolis
®
DMX Access Multiplexer Installation Manual, 365-
372-304.
Local software download
DMX supports the following local software downloads.
• Local software installation via File Transfer Protocol (FTP) from a
WaveStar
®
CIT connected to the
CIT LAN
(IAO LAN) port on the
SYSCTL circuit pack faceplate or the
J16 IAOLAN
(IAO LAN) port on the shelf backplane. Software installation via FTP requires the following:
– FTP Client software is enabled on the NE
– IP parameters are provisioned on the NE.
• Remote software download via an FTAM-FTP gateway to DMX.
The FTAM-FTP gateway is also referred to as the file transfer translation device (FTTD).
Important!
Download time over FTP has been reduced from 7 minutes to approximately 4 minutes.
Important!
FTP must be used to install software when using the
Windows
XP Operating System.
Remote software download
Remote software download reduces the need to travel to remote sites when the software version of multiple DMX systems is being upgraded throughout a network.
• Remote software download via an FTAM-FTP gateway to DMX.
The FTAM-FTP gateway is also referred to as the file transfer translation device (FTTD).
• Software copy from the local DMX to a remote:
– DMX
– DMXtend
– DMXplore
– DDM-2000 OC-3
– DDM-2000 OC-12
– FiberReach
...........................................................................................................................................................................................................................................................
6 - 2 8
365-372-300
Issue 8.0 September 2006
Software Download (Generic)
Operations, Administration, Maintenance, and Provisioning
Important!
The software must be in the dormant area of DMX.
Both the local and remote NEs must have an active software generic.
• Remote software download via FTP to DMX. Both the FTP gateway network element (GNE) and remote NE must have an active software generic.
Important!
Release 2 and later software supports IP tunneling.
Impact of software download and activation
Initial local software installation temporarily disrupts operations communications because the system controller is reset to activate the software immediately.
Other local software downloads temporarily disrupt operations communications, too, because a system controller reset is involved, but the dormant software is not activated immediately.
Remote software download or copy of compressed dormant software is accomplished without any disruption of operations communications
(that is, no system controller resets), because the dormant software is not activated immediately.
If there is no valid generic or database on the controller, or if there are multiple valid generics or databases when the shelf resets, the shelf enters maintenance mode, using the default database. If necessary, the
WaveStar CIT wizard will guide the user through the download/restore process and prompt generic and database selection.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
6 - 2 9
Software Download (Generic)
Operations, Administration, Maintenance, and Provisioning
Remote software download compatibility
The following table lists DMX remote software download compatibility with other products.
Table 6-6 Remote Software Download Compatibility
Product
DMX
DMXplore
DMXtend
DDM-2000 OC-3
DDM-2000 OC-12
FiberReach
From PC Connected to:
DMX
Front Serial Port
yes yes yes yes yes yes
Digital signature capability
NOTE:
DMX shelves running pre-R6.0 software releases can only perform downloads to other pre-R6.0 DMX or other pre-R4.0 DMXtends. Any shelf running R6.0 and later releases can download previous releases.
In Release 3.0 and later releases, DMX verifies software downloads using a digital signature. When FTP over TCP/IP is used for a software download, a digital signature is transmitted with the software download and verified by the network element. If the verification fails, DMX reports an autonomous message and the software download fails. The digital signature is discarded after verification.
Checking the digital signature of software download can be enabled or disabled using the
Configuration > Software > Software Download
command.
...........................................................................................................................................................................................................................................................
6 - 3 0
365-372-300
Issue 8.0 September 2006
Operations, Administration, Maintenance, and Provisioning
Database Backup and Restore
............................................................................................................................................................................................................................................................
Overview
This section describes the database backup and restore feature in DMX.
IP tunneling is required to support remote database backup/restore for remote DMX systems.
The DMX uses the following connections to perform database backup and restore:
• A direct IP connection
• OSI connectivity to an FTP GNE.
• FTAM Backup and Restore
Database backup
DMX can back up all provisionable data via a local or remote FTP file transfer. In Release 3.0 and later releases, data can be backed up to a remote operations system via an FTAM-FTP gateway. The FTAM-FTP gateway is also referred to as the file transfer translation device
(FTTD).
The backup database is stored on a WaveStar
®
CIT, and Navis™
Optical Element Management System (Navis™ Optical EMS), or another FTP server. For information about the
Configuration>Software>Remote Backup
command, refer to the WaveStar
®
CIT help.
Database restore
In the event of a catastrophic failure, DMX can restore all provisionable data (from the backup file) via local or remote FTP. In
Release 3.0 and later releases, data can be restored from a remote operations system via an FTAM-FTP gateway. The FTAM-FTP gateway is also referred to as the file transfer translation device
(FTTD).
The backup database maybe stored on a WaveStar
®
CIT, and Navis™
Optical Element Management System (Navis™ Optical EMS), or another FTP server. For information about the
Configuration>Software>Remote Restore
command, refer to the WaveStar
®
CIT help. For more information about restoring the network element database, refer to The User Operations Guide.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
6 - 3 1
Database Backup and Restore
Operations, Administration, Maintenance, and Provisioning
Automatic database backup
DMX supports automatic database backups. This allows users to establish a backup interval, date, and time. The database backups may be saved on the WaveStar
®
CIT or another FTP server.
The user can also specify the number of backups to destination files before overwriting those same files with subsequent backups. To eliminate the scenario of multiple DMX systems initiating automatic backups simultaneously, DMX does not support a default scheduled backup date/time; the user must provision their own date/time. For information about the
Configuration>Software>Configure Auto Backup
Interval
command, refer to the Wavestar CIT help.
...........................................................................................................................................................................................................................................................
6 - 3 2
365-372-300
Issue 8.0 September 2006
Operations, Administration, Maintenance, and Provisioning
Maintenance Signaling
............................................................................................................................................................................................................................................................
Alarm indication signals
Alarm indication signals (AIS) are one example of maintenance signals that notify equipment downstream that a failure has been detected and alarmed by upstream equipment. AIS is a signal that replaces the normal traffic signal when a maintenance alarm indication has been activated.
RAI and RDI are then used to notify a piece of equipment upstream that a failure has been detected by downstream equipment.
Compliance
Maintenance signaling is compliant with SONET (Telcordia
Technologies GR-253) and asynchronous (Telcordia Technologies TR-
TSY-000191) network requirements. Alarm indication signals include
SONET OC-n line AIS, STS-1 path AIS, virtual tributary (VT) path
AIS, DS3 AIS, and DS1 AIS. Remote defect indication signals include
STS-1 path RDI and VT path RDI. Other maintenance signals include
STS-1 path unequipped, VT path unequipped, Loss of Signal (LOS,
Loss of Frame (LOF), and Loss of Pointer (LOP).
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
6 - 3 3
Operations, Administration, Maintenance, and Provisioning
Fault Detection, Isolation, and Reporting
............................................................................................................................................................................................................................................................
Overview
DMX continuously monitors incoming signals and internal system conditions. Incoming signals are monitored at the line level for loss of signal (LOS), loss of frame (LOF), and Alarm Indication Signal (AIS), and BER threshold crossings. Incoming signals are monitored at the path level for loss of pointer (LOP), Alarm Indication Signal (AIS), unequipped (UNEQ), and BER threshold crossings.
The BER threshold crossings are detected for DS1, DS3, E1, EC-1,
VT1.5, OC-3, OC-12, OC-48, OC-192, STS-1, STS-3c, STS-12c, and
STS-48c signals.
Fault detection
In addition to detecting line and path faults, the system also detects internal circuit pack faults. When an internal fault is detected, automatic diagnostics isolate the faulty circuit pack. Faults are reported to local technician and OSs so that technician dispatch and repair decisions can be made. If desired, OS personnel and local technicians can use the PC-CIT to gain more detailed information on the fault condition.
Fault isolation
All fault conditions detected by the system are stored and made available to be reported, on demand, through the PC-CIT. In addition, a history of past alarm and status conditions and PC-CIT events is maintained and available for on-demand reporting. Each event is realtime and date stamped.
Fault reporting
The system can also report all detected alarm and status conditions through the appropriate office alarm relays, SYSCTL faceplate LEDs, transmission circuit pack LEDs, and TL1 interfaces.
...........................................................................................................................................................................................................................................................
6 - 3 4
365-372-300
Issue 8.0 September 2006
Operations, Administration, Maintenance, and Provisioning
Loopbacks and Tests
............................................................................................................................................................................................................................................................
Overview
The DMX allows technicians to perform loopback tests on all low- and high-speed interfaces. Low-speed DS1, DS3, E1, and EC-1 electronic loopbacks, directed toward the high-speed line (terminal loopback), are individually controllable from the CIT or the OS interface. Active electronic loopbacks are shown by the ABN LED on the SYSCTL faceplate and in the alarm and status report. EC-1, E1, DS1, DS3, and
Ethernet facility loopbacks toward the DSX are also available.
Manual optical loopbacks
Front access to the optical connectors on the optical line interface unit
(OLIU) circuit pack allows easy manual optical loopback. This loopback is performed by connecting a fiber jumper from the OLIU circuit pack output to its input. In some cases a lightguide buildout assembly is required to prevent receiver overload when performing loopbacks.
Internal testing capabilities
Technicians can use the internal testing capabilities for installation and manual troubleshooting. The DS1 and DS3 test signal generators and detectors are integrated into the system, eliminating the need for external test equipment to perform transmission tests.
Specific testing
DMX also allows technicians to test specific system components. In addition to the automatic diagnostics, DMX provides tests for LEDs, office alarms, and the SYSCTL circuit pack.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
6 - 3 5
Operations, Administration, Maintenance, and Provisioning
Test Access
............................................................................................................................................................................................................................................................
Overview
Test access, a traditional DCS function, allows the user visibility into any VT1.5/STS-1 signal in the network. Test access aids users in turning up connections and in identifying faults in existing service connections. DMX supports three different types of test access. The non-intrusive method simply taps the VT1.5/STS-1 channel as it passes through the system and routes it to an external testing device. The more intrusive mode splits the VT1.5/STS-1 from the incoming signal and sends it to an external testing device. The third form of test access involves using the internal test head, located on the LNW59 only, to generate and detect Pseudo Random Bit Sequences (PRBSs) on up to
12 STS-1s or 4 STS-3(c) signals. Test access facilitates DMX functioning in a DCS application.
PRBS generation/detection
For detailed information regarding internal test access using PRBS, refer to
Test access interworking
DMX supports interworking with various Test-Head vendors.
Test access rates
DMX supports test access sessions at the STS-1, STS3(c) and VT1.5 rates.
Test access modes
DMX supports test access sessions in the following modes:
• MONE
• MONEF
• SPLTE
• SPLTEF
• SPLTA (for PRBS generation/detection only)
...........................................................................................................................................................................................................................................................
6 - 3 6
365-372-300
Issue 8.0 September 2006
Test Access
MONE mode
Operations, Administration, Maintenance, and Provisioning
The MONE mode is used to monitor the E Tributary input signal of a one-way cross-connection or an idle E Tributary input signal (no crossconnection).
The following figure shows an example of the MONE mode used to monitor the E Tributary input signal of 2 separate one-way crossconnections.
Network Element
A Direction
E
Tributary
F
Tributary
B Direction
Test Access
Tributary 1
Testing System
Legend:
- No connection
MA-DMX-373
If the F Tributary is entered, the F Tributary must be the destination of a one-way cross-connection that has the E Tributary as the source. If the
E Tributary is part of a one-way multicast cross-connection, entering the F Tributary is optional. The system automatically retrieves the other end. The E Tributary or F Tributary can not be on an Ethernet circuit pack.
SPLTE mode
The SPLTE mode is used to test the E Tributary signal.
The following figure shows an example of the SPLTE mode used to test the E Tributary signal of 2 separate one-way cross-connections.
Network Element
A Direction
AIS
E
Tributary
F
Tributary
B Direction
Test Access
Tributary 1
Testing System
Legend:
- No connection
MA-DMX-374
The E Tributary signal is split from the F Tributary signal. AIS is transmitted on the outgoing F Tributary signal. and the incoming F
Tributary signal is terminated. If more than one independent one-way cross-connection exists to the E Tributary, the SPLTE mode is denied.
The E Tributary can also be idle (no cross-connection). The E Tributary or F Tributary cannot be on an Ethernet circuit pack.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
6 - 3 7
Test Access
STS-1 Test Access Matrix
Operations, Administration, Maintenance, and Provisioning
The table below provides all the STS-1 test access specifications supported by DMX. The numbers in the table below (e.g. R4.0, R5.1, etc....) represent the software release number in which that configuration is first supported. Test access on STS-3(c) signals is only supported in SPLTA, SPLTE, and MONE modes using the internal test head located in the VLF Main packs for PRBS generation/detection
Table 6-7 STS-1 Test Access
TATRIBs
Main Add/
Drop STS1
XC To: d,e
Thru XC
ETRIB and
FTRIB
DS3/EC1
(FN A-D) hairpin to: d,e
OC3/12/48
(FN A-G) hairpin to: d,e
OC-192 h
(M1/M2) hairpin to
Slot Signal
A-G DS3/
EC1
A-G OC-3/
12/48 f,g
A-D DS3/
EC1
A-G OC-3/
12/48 f,g
TMUX i
A-D DS3/
EC1
A-G OC-3/
12/48 f,g
M1/
M2
OC-
192
R4.0
R4.0
BLSR R4.0
UPSR R5.1
R4.0
R4.0
R7.0
R4.0
R4.0
R7.0
A-D Slots (elect)
DS3/EC1 TMUX
LNW16
LNW19
LNW19B
LNW20
LNW18
LNW20
A-G Slots
1+1 only b
OC-3/
12
LNW36
LNW37
LNW46 a
(opt)
M1/M2
Slots a
1+1 only b
(opt)
OC-3/
12
LNW31
OC-48 OC-12/48/
192 h
LNW45
LNW49
LNW62
All Main
OLIUs
Deny
Deny
Deny
Deny
Deny
Deny
R7.0
Deny
Deny
R7.0
R4.0
R4.0
R4.0
R5.1
R4.0
R4.0
R7.0
R4.0
R4.0
R7.0
R5.1
R5.1
R5.1
R5.1
R5.1
R5.1
R7.0
R5.1
R5.1
R7.0
R4.0
R4.0
R4.0
R5.1
R4.0
R4.0
R7.0
R4.0
R4.0
R7.0
R4.0
R4.0
R4.0
R5.1
R4.0
R4.0
R7.0
R4.0
R4.0
R7.0
...........................................................................................................................................................................................................................................................
6 - 3 8
365-372-300
Issue 8.0 September 2006
Test Access
Operations, Administration, Maintenance, and Provisioning
Notes
a.TATRIB1 and TATRIB2 are always connected to the same optical interface b.Intended for unprotected interfaces to locally-connected testheads only;
Network-connected testheads - Future c.EC1 mode interfaces only.
d.Test Access of locked cross connections restricted to electrical TATRIBs e.Test Access of UPSR Dual Ring Interworking cross connections not supported f.LNW45 and LNW49 begins in R5.1
g.Test access of low-speed BLSR cross-connections not supported h.All high-speed Main OLIUs allow the STS-1 test access modes specified in this table. Hairpins from high-speed Main interfaces to other high-speed Main interfaces only allowed on the LNW59 because it is the only Main OC-192 pack with multiple ports. Generation and detection of PRBS only supported on the LNW59.
i.TMUX test access in the G slots only supported using the LNW20 in portless mode.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
6 - 3 9
Test Access
VT1.5 Test Access Matrix
Operations, Administration, Maintenance, and Provisioning
Important!
The "dual tatrib" modes (MONEF and SPLTEF) of VT test access are not possible when the system is equipped with small/ medium VT fabric Main OLIUs. This applies to all systems equipped with OC3 or OC12 Main OLIUs.
The table below provides all the VT1.5 test access specifications supported by
DMX
. The numbers in the table below (e.g. R4.0, R5.1, etc) represent the software release number in which that configuration is first supported.
Table 6-8 VT1.5 Test Access
TATRIBs
ETRIB and
FTRIB d
Main
Add/
Drop
VT1.5
XC To: e,f
DS1/E1
TMUX
(FNA-D)
VT1.5 hairpin to: e,f
A-
D
A-
G
Slot Signal
A-
D
A-
G
DS3/
EC1 c
R4.0
TMUX
DS1/E1
R4.0
R4.0
R4.0
OC-3/12/
48 g
DS3/
EC1 c
TMUX
R4.0
R4.0
DS1/E1 R4.0
OC-3/12/
48 g
R4.0
A-D Slots
EC1
LNW16
LNW19
LNW19B
LNW20
A-G Slots aunprotected 1+1 only b
TMUX
LNW18
LNW20
DS1/E1 OC-3/
12
LNW6/
7/8
LNW36
LNW37
LNW46
OC-3/
12
LNW45
LNW49
OC-48
LNW31
LNW62
M1/M2
Slots a
1+1 only b
OC-12/
48/192 i
All Main
OLIUs
R4.0
R4.0
R4.0
R4.0
R4.0
R4.0
R4.0
R4.0
R4.0
R4.0
R4.0
R4.0
R4.0
R4.0
R4.0
R4.0
R4.0
R4.0
R4.0
R4.0
R4.0
R4.0
R4.0
R4.0
R5.1
R5.1
R5.1
R5.1
R5.1
R5.1
R5.1
R5.1
R4.0
R4.0
R4.0
R4.0
R4.0
R4.0
R4.0
R4.0
R7.0
R7.0
R7.0
R7.0
R7.0
R7.0
R7.0
R7.0
...........................................................................................................................................................................................................................................................
6 - 4 0
365-372-300
Issue 8.0 September 2006
Test Access
TATRIBs
Operations, Administration, Maintenance, and Provisioning
ETRIB and
FTRIB
(cont.) d
OC3/12/
48 (FN
A-G)
VT1.5 hairpin to: e,f
A-
D
A-
G
M1/
M2
DS3/
EC1 c
TMUX
DS1/E1 f
OC-3/12/
48 g
TMUX
(LNW20 portless only)
OC-12/
48/192 i
LNW16
LNW19
LNW19B
LNW20
R4.0
R4.0
R4.0
R4.0
R7.0
R4.0
A-D Slots
EC1
A-G Slots aunprotected 1+1 only b
TMUX
LNW18
LNW20
DS1/E1 OC-3/
12
LNW6/
7/8
LNW36
LNW37
LNW46
OC-3/
12
LNW45
LNW49
OC-48
LNW31
LNW62
M1/M2
Slots a
1+1 only b
OC-12/
48/192 i
All Main
OLIUs
R4.0
R4.0
R4.0
R4.0
R7.0
R4.0
R4.0
R4.0
R4.0
R4.0
R7.0
R4.0
R4.0
R4.0
R4.0
R4.0
R7.0
R4.0
R5.1
R5.1
R5.1
R5.1
R7.0
R5.1
R4.0
R4.0
R4.0
R4.0
R7.0
R4.0
R4.0
R4.0
R4.0
R4.0
R7.0
R4.0
Notes
a. TATRIB1 and TATRIB2 are always connected to the same optical interface b. Intended for unprotected interfaces to locally-connected testheads only;
Network-connected testheads - Future c. EC1 mode interfaces only.
d. Large VT Fabric Mains Only; restrictions apply for LNW26/26B-type, or any OC3/12 Main OLIU.
e. Test Access of locked cross connections restricted to electrical TATRIBs.
f. Test Access of UPSR Dual Ring Interworking cross connections not supported.
g. LNW45 and LNW49 begins in R5.1.
h. Test access of low-speed BLSR cross-connections not supported.
i. All high-speed Main OLIUs allow the STS-1 test access modes specified in this table. Generation and detection of PRBS only supported on the LNW59
(R7.0).
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
6 - 4 1
Test Access
Operations, Administration, Maintenance, and Provisioning
PRBS generation/detection
Test access using PRBS generation/detection via the internal test head on the VLF Main allows the user to test network, NE, and facility performance/integrity without an external test head. The VLF Mains introduced in R7.0 contain an internal test head that can generate and detect errors in Pseudo Random Bit Sequences (PRBSs). This capability is not meant to wholly eliminate the use of external equipment for tests, but can be used for expediency, less complicated tests, and where non-manual set-up is advantageous. PRBS enabled test access involves initiating test access, inserting a test signal (i.e. a
PRBS) generated internal to the NE, and/or monitoring a received test signal internal to the NE. PRBS generation/detection is supported on
STS1 and STS3c tributaries.
DMX allows up to 12 test access sessions at a time and for a mix of the old style test access sessions described on the previous pages
(specifying tatrib(s)) or the new-style session (to the internal test head) within the 12 allowed sessions. The internal test head hardware supports signal generation on up to 12 STS1s, and signal detection on up to 12 STS1s. The generators and detectors are separately allocated.
Test access for STS3c rates is new in R7.0. Only internal test access is supported on STS3c signals; requests using the tatrib parameter(s) will be denied. It’s important to note that when a generator or detector is allocated to an STS3c session, it uses 3 of the 12-STS1 capacity, and that 3 generators or detectors on the STS3c boundary must be available.
Generation and detection functionality
PRBS Generation is totally independent of detection and error counting. The only similarity is that they both occur in the context of test sessions. One session may produce a signal that is detected/ measures by a different session (in the same, or different DMX).
While measurement/monitoring of incoming PRBS signals is occurring, the shelf collects total measurement session counts and PMstyle counts, including 15-minute and day bins tied to the time-of-day clock. The bins are retrieved by the user on-demand and are freed when the test access session (not the measuring session) ends. Bins survive a non-powerup shelf restart and are initialized by a power-up shelf restart.
...........................................................................................................................................................................................................................................................
6 - 4 2
365-372-300
Issue 8.0 September 2006
Test Access
Operations, Administration, Maintenance, and Provisioning
Modes allowed for PRBS functionality
DMX supports PRBS enabled internal test access sessions in the following modes:
• MONE
• SPLTE
• SPLTA (new in R7.0)
DMX must be in MONE mode to initiate a PRBS enabled test access session. The mode must then be changed to either SPLTE or SPLTA in order to support the configurations detailed below.
Testing to a far-end loopback
This configuration involves a SPLTE test session at a single DMX node, with generation and detection at the same node. The tributary under test must be cross-connected.
AIS
Network Element
X
E
Tributary
Loopback
X
PRBS
Generator
PRBS
Detector
DMX Test Node: SPLTE Mode
Far-end Node (may be other vendor’s equipment or another DMX)
JK-E-21
DMX is first set to MONE mode and then changed to SPLTE mode.
AIS is inserted into the tributary being tested until the PRBS generator is set to generate and insert a bit sequence on that tributary. The
Generator and detector are then connected to the tributary. The PRBS is inserted into the tributary, sent to and looped back at the far-end, and then monitored for errors by the PRBS detector located on the VLF
Main.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
6 - 4 3
Test Access
Operations, Administration, Maintenance, and Provisioning
Head-to-head testing
This configuration involves generating a signal at one node (node A), and monitoring the signal at a different node (node B). Note that the tributary under test at node A must be cross-connected. The tributary at node B may or may not be cross-connected.
E
Tributary
X
E
Tributary
PRBS
Generator
DMX Test Node A: SPLTA Mode
PRBS
Detector
DMX Test Node B: SPLTA Mode
JK-E-23
Node A and B are first set to MONE mode, but while the generator on
Node A is then connected to the tributary and the detector on Node B is also connected to the tributary. The PRBS signal originating at Node A is monitored for errors by the PRBS detector located on the VLF Main in Node B.
Total network testing
This configuration involves a SPLTA test session at a single DMX node, with generation and detection at the same node. The tributary under test must be cross-connected.
Loopback
Loopback
E
Tributary
Far-end Node (may be other vendor’s equipment or another DMX)
X
PRBS
Detector
PRBS
Generator
DMX Test Node: SPLTA Mode
Far-end Node (may be other vendor’s equipment or another DMX)
JK-E-21
DMX is first set to MONE mode and then changed to SPLTA mode.
AIS is inserted into the tributary being tested until the PRBS generator is set to generate and insert a bit sequence on that tributary. The generator and detector are then connected to the tributary. A PRBS is inserted into the tributary, sent to and looped back at the far-end, passed-through Node A and sent to a far-end node in the other direction where it is looped back to Node A. The PRBS signal is then monitored for errors by the PRBS detector located on the VLF Main in Node A before the tributary is terminated.
...........................................................................................................................................................................................................................................................
6 - 4 4
365-372-300
Issue 8.0 September 2006
Operations, Administration, Maintenance, and Provisioning
WaveStar
®
CIT
Overview
............................................................................................................................................................................................................................................................
Purpose
This section describes the WaveStar
®
CIT.
Contents
The information provided in this section includes:
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
6 - 4 5
Operations, Administration, Maintenance, and Provisioning
Introduction to the WaveStar
®
CIT
............................................................................................................................................................................................................................................................
What is the WaveStar
®
CIT?
WaveStar
®
CIT functionality
TL1 interface
The WaveStar
®
CIT is the primary tool used to interface with DMX. It is a personal computer (PC) with the WaveStar
®
CIT user-interface software installed.
The WaveStar
®
CIT supports the following user interface options:
• Graphical user interface (GUI)
• TL1 command builder
• TL1 cut-through access to other NEs
The WaveStar
®
CIT is referred to as the “WaveStar
®
CIT” because the
DMX user-interface software is integrated with the WaveStar
®
CIT software for the WaveStar
®
products.
The WaveStar
®
CIT provides an easy-to-use interface and security features to prevent unauthorized access. The WaveStar
®
CIT supports the following:
• Local access control based on login and password
• OSI neighbor discovery for easy access to the local NE(s)
• User provisioning of cross-connections, equipment, Ethernet services, software management, protection provisioning, and fault management
• Reports on NE equipage, cross-connections, alarms, and states
The interface between the WaveStar
®
CIT and the DMX supports TL1 messages. This interface allows the WaveStar
®
CIT to issue TL1 commands and receive responses, as well as receive TL1 alarm reports from autonomous events that are detected by the DMX.
...........................................................................................................................................................................................................................................................
6 - 4 6
365-372-300
Issue 8.0 September 2006
Operations, Administration, Maintenance, and Provisioning
WaveStar
®
CIT Access
............................................................................................................................................................................................................................................................
WaveStar
®
CIT access methods
The WaveStar
®
CIT can access a network element using the following:
• Front and rear IAO LAN ports supporting OSI communications
• Front and rear IAO LAN ports supporting TCP/IP communications
• Front serial port
• Rear serial port
WaveStar
®
CIT direct local access
The recommended method for temporary local access is to connect the
WaveStar
®
CIT to DMX via the CIT
LAN
port on the system controller
(
SYSCTL
) circuit pack faceplate.
The WaveStar
®
CIT can also be connected to the serial
CIT RS-232
port on the
SYSCTL
circuit pack faceplate.
Figure 6-8 CIT Direct Local Access
OSI or TCP/IP
Front IAO LAN Port
Metropolis
®
DMX
Serial
Front Serial Port
SYSCTL nc-dmx-001
Important!
When the WaveStar
®
CIT is directly connected to the CIT LAN port (not to an Ethernet LAN hub), a LAN crossover cable is required.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
6 - 4 7
WaveStar® CIT Access
WaveStar
®
CIT access via rear IAO LAN Port
Operations, Administration, Maintenance, and Provisioning
The rear IAO LAN port supports local and/or remote WaveStar
®
CIT access. The figure below shows how the rear IAO LAN port can be used to provide local WaveStar
®
CIT access by connecting to a local
Ethernet LAN hub. The WaveStar
®
CIT is depicted as being local but could also be remote. For local access, either the OSI protocol stack or
TCP/IP could be used. For remote access, typically TCP/IP would be used.
Figure 6-9 WaveStar
®
CIT Access via rear IAO LAN Port
WaveStar
®
CIT
OSI or
TCP/IP
10/100BaseT Ethernet
LAN Hub
OSI or
TCP/IP
OSI or
Rear IAO
TCP/IP
LAN Port
Metropolis
®
DMX
OC-48
UPSR with
DCC
Metropolis
®
DMX
Rear IAO
LAN Port
Metropolis
®
DMX
OC-48
UPSR with
DCC
Metropolis
®
DMX nc-dmx-005
WaveStar
®
CIT access via
TCP/IP LAN
For security reasons (and per SIF standards), neither local nor remote
TCP/IP access via the DMX IAO LAN ports is allowed by default.
...........................................................................................................................................................................................................................................................
6 - 4 8
365-372-300
Issue 8.0 September 2006
WaveStar® CIT Access
Operations, Administration, Maintenance, and Provisioning
WaveStar
®
CIT remote access using DCC
A WaveStar
®
CIT with direct physical access to a local DMX can also be used to access remote NEs with DCC connectivity to the local
DMX. WaveStar
®
CIT remote access over DCC is functionally equivalent to WaveStar
®
CIT direct access.
Figure 6-10 WaveStar
®
CIT Access via DCC
WaveStar
®
CIT
IAO LAN (OSI or TCP/IP) or front serial ports
Metropolis
®
DMX
OC-48
UPSR with
DCC
Metropolis
®
DMX nc-dmx-004
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
6 - 4 9
WaveStar® CIT Access
Operations, Administration, Maintenance, and Provisioning
Remote access to the rear serial port
DMX can also be accessed remotely via dialup modems, but not by the
WaveStar
®
CIT software. The rear serial port when equipped with the recommended cable is configured as DTE to allow a permanent modem connection.
A PC with a terminal emulation software package, such as
HyperTerminal, can be used for access to DMX’s rear serial port via dialup modems. The PC can use its internal modem or an external modem (shown). This form of access supports TL1 messages only, and can be used to access remote NEs with DCC connectivity to the DMX with the modem connection.
Figure 6-11 Remote WaveStar
®
CIT Access via modem
WaveStar
®
CIT
Serial
Modem
Modem
Rear
Serial Port
Metropolis
®
DMX
OC-48
UPSR with
DCC
Metropolis
®
DMX nc-dmx-006
...........................................................................................................................................................................................................................................................
6 - 5 0
365-372-300
Issue 8.0 September 2006
Operations, Administration, Maintenance, and Provisioning
Protection Switching
Overview
............................................................................................................................................................................................................................................................
Purpose
This section describes the types and functions of protection switching in the DMX Access Multiplexer.
Contents
The following protection switching topics are discussed in this section:
Path Protection Switching (Path Switched Rings)
Line Protection Switching (Line Switched Rings)
Link Aggregation (LNW70 LAN ports)
Application modes
There are five types of protection application modes, listed below:
•
• UPSR
• Linear 1+1
—Unidirectional 1+1
—Bidirectional 1+1
—Bidirectional optimized 1+1
• 0x1
• 0x1Sn
The UPSR application mode provides ring path protection switching on high-speed interfaces.
The linear application mode provides 3 types of protection switching:
Unidirectional 1+1. Bidirectional 1+1, and Bidirectional Optimized
1+1. It is functionally equivalent to a 1+1 protected configuration, providing path switching on all paths within a high-speed line if that particular line fails.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
6 - 5 1
Overview
Operations, Administration, Maintenance, and Provisioning
R6.0 added support of revertive unidirectional and bidirectional 1+1, in additional to the non-revertive option offered in past releases.
0x1Sn mode
When not equipped with VLF Main packs (LNW59), DMX supports an unprotected 0x1Sn mode. This option is user-provisionable on a perport basis. 0x1S1 and 0x1S2 are provisionable applications for LS OCn port pairs. For 0x1S1, the port in slot 1 is unprotected and the companion port in slot 2 is unused. For 0x1S2, the port in slot 2 is unprotected and the companion port in slot 1 is unused.
...........................................................................................................................................................................................................................................................
6 - 5 2
365-372-300
Issue 8.0 September 2006
Overview
True 0x1 mode
Operations, Administration, Maintenance, and Provisioning
With the introduction of the VLF Main pack (LNW59) in R7.0, DMX allows true 0x1 unprotected circuit packs. That means that any slot can be equipped with any pack (some restrictions apply). Two of the same circuit packs can also populate adjacent slots in the same group (this includes some Ethernet packs). For detailed information on circuit pack/slot equipage restrictions in 0x1 mode, refer to
.
In the case of OLIUs (SONET optical line interface packs), all ports in a pack must be set to 0x1 application in order for a different pack to be used in the companion slot. If any pair of lines is provisioned for a protected application (+1, UPSR, BLSR), then both packs in the group must be of the same type.
True 0x1 replaces 0x1Sn functionality when VLF Mains are used. True
0x1 supports all the capabilities 0x1Sn allow, but adds the capability for both slots of a single group to function independently. 0x1Sn will still be supported when the shelf is equipped with non-VLF Mains.
True 0x1 is only available on the low-speed/tributary packs, not on the
Main (M1/M2) interfaces.
When two circuit packs in the same low-speed group are operating in
0x1 mode, all provisioning, reporting and retrieval (of alarms) associated with the pack, ports and tributaries in Slot 1 are independent of the provisioning, reporting and retrieval associated with the pack, ports and tributaries in Slot 2.
When provisioned for 0x1 operation, the affect on service and severity of alarms issued against a pack in Slot 1 of a particular group are independent from the affect on service and the severity of the alarms issued against the pack in Slot 2 of that group.
When DMX is equipped with VLF Mains, all 1-way cross-connections presently supported on an unprotected port/line (including ports/lines on an unprotected pack) in one slot of an LS group can be supported independently and simultaneously on an unprotected port/line in either slot of a Function or Growth group. 1-waypr cross-connections are not allowed to be sourced from 0x1 interfaces.
True 0x1 enables hairpin cross-connections between channels on packs in different slots of the same Function or Growth group.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
6 - 5 3
Overview
Operations, Administration, Maintenance, and Provisioning
Ethernet interface protection
On the WAN (SONET) side of the network, DMX utilizes standard
IEEE 802.1D and fast 802.1w spanning tree protection for multipoint applications and/or STS-1 UPSR protection (for point-to-point applications). Spanning Tree protection is not available on the 10/100-
FEPL (LNW71) pack. See the section entitled Spanning Tree (6-61) for
more information.
DMX also supports Resilient Packet Ring (RPR) protection for
Ethernet interfaces using the LNW78. For more information on RPR bridging and switching refer to the sections entitled
In R7.0, DMX adds support for link aggregation on any two LNW70
LAN ports of the same rate (i.e. 100 or 1000 Mbps), operating in switched mode. In R7.0, the two ports comprising a LAG must be located on the same pack.
Link aggregation can also provide facility protection on LNW70 LAN ports. Link aggregation is also able to remove failed links automatically, thereby providing a means of facility protection. When a link fails, traffic is shifted to the remaining links in that Link
Aggregation Group (LAG). More links than are needed can be added to the group and each is active until it fails (similar to utilizing LCAS protection for SONET tributaries). For more information on link aggregation, refer to
Link Aggregation (LNW70 LAN ports)
.
...........................................................................................................................................................................................................................................................
6 - 5 4
365-372-300
Issue 8.0 September 2006
Operations, Administration, Maintenance, and Provisioning
Line Protection Switching
............................................................................................................................................................................................................................................................
Overview
DMX offers 5 modes of linear protection switching: unidirectional 1+1 non-revertive line switching, bidirectional 1+1 non-revertive, unidirectional 1+1 revertive line switching, bidirectional 1+1 revertive, and bidirectional optimized 1+1 protection switching. All three types of linear protection switching occur automatically in response to detected faults, as well as in response to external commands from technicians at a local or remote CIT or OS.
Protection switching priorities
DMX uses standard protection switching priorities as follows:
• Lockout of protection
• Forced switch (FS)
• Automatic switch: signal fail (SF)
• Automatic switch: signal degrade (SD)
• Manual switch (MS)
DMX allows you to provision these parameters with different priorities in relation to each other. For example, SF can be set with a higher priority than FS and vice versa.
Unidirectional and bidirectional 1+1 non-revertive and revertive line switching use switch procedures as specified by the SONET standards.
DMX offers bidirectional optimized 1+1 protection switching which uses switching procedures specified in ITU-T G.841, Annex B.
Bidirectional optimized 1+1 is designed to enable interoperability between DMX and SDH equipment. It is a separate switching scheme from standard 1+1 bidirectional and does not work with standard 1+1.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
6 - 5 5
Line Protection Switching
Operations, Administration, Maintenance, and Provisioning
Automatic line switching
Automatic line switches are initiated by signal fail and signal degrade conditions on the received OC-n signal. This signal’s BER is calculated from violations in the SONET line overhead B2 parity byte. Signal fail is declared for incoming loss of signal, loss of frame, line AIS, or a
BER exceeding a provisionable 10
-3
to 10
-5
threshold, while a BER exceeding a provisionable 10
-5
to 10
-9
threshold causes the signal degrade condition. A line protection switch is completed within 50 milliseconds of the onset of a hard failure such as a fiber cut.
In multispan applications (for example, hubbing), each OC-n span switches independently. For example, in hubbing applications, a switch on the central office-to-hub span will not cause switches on any of the hub-to-remote spans. Similarly, a line switch on a hub-to-remote span will not propagate to other hub-to-remote or central office-to-hub spans.
...........................................................................................................................................................................................................................................................
6 - 5 6
365-372-300
Issue 8.0 September 2006
Operations, Administration, Maintenance, and Provisioning
Path Protection Switching (Path Switched Rings)
............................................................................................................................................................................................................................................................
Overview
DMX supports path switched ring applications using the path protection switching schemes described in Telcordia Technologies GR-
1400. This scheme offers 60-millisecond restoration times and simple network administration for access applications. The ring facility consists of two fibers, with service and protection rotating in opposite directions. Each input is bridged and transmitted in both directions around the ring. The receiving end terminal monitors the quality of both signals and selects the best signal to drop.
UPSR configurations
DMX supports the following OC-3/OC-12/OC-48/OC-192 path switched ring configurations:
• OC-3: VT1.5/STS-1/STS-3c
• OC-12: VT1.5/STS-1/STS-3c/STS-12c
• OC-48: VT1.5/STS-1/STS-3c/STS-12c/STS-48c
• OC-192: VT1.5/STS-1/STS-3c/STS-12c/STS-48c
Path protection switching is non-revertive. A manual path protection switching command allows switching to the other path for ease of ring maintenance. STS-n path switching is indirectly triggered by the line defects LOS and LOF by virtue of the fact that these generate downstream path AIS. The system also supports VT path protection switching based on VT AIS, LOP, unequipped, and signal degrade.
DMX also supports STS-1/STS-3c non-revertive path protection switching on low-speed OC-3 optical interfaces, STS-1/STS-3c/STS-
12c non-revertive path protection switching on low-speed OC-12 optical interfaces, and STS-1/STS-3c/STS-12c non-revertive path protection switching on low-speed OC-48 optical interfaces. Path protection is user-provisionable on a per-cross-connection basis when the port is set to UPSR.
Unswitched UPSR
DMX provides an unprotected cross-connect mode, referred to as unswitched UPSR, on OC-3/12/48 low-speed ports and OC-12/48/192 high-speed UPSRs. This option is user-provisionable on a per crossconnection basis and supports single- and dual-homed ring on ring topologies. Path protection and internal equipment (switch fabric) protection is disabled in Unswitched configurations.
Mixed protection modes
By supporting protection mode provisioning on a per port basis, DMX provides for the mixing of protection modes across the ports of a multiport pack.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
6 - 5 7
Path Protection Switching (Path Switched Rings)
Locked DS1/DS3 Cross
Connections
Operations, Administration, Maintenance, and Provisioning
In the “locked” mode, DMX does not select the best signal from both rotations of a UPSR. Instead, traffic is added and dropped (locked) from one rotation of the ring only (provisionable). The main advantage of locked DS1/DS3 cross-connections is the lack of UPSR switching. This feature is extremely useful in utility applications.
Locked VT Cross
Connections (R7.0)
In the “locked” mode, DMX does not select the best signal from both rotations of a UPSR. Instead, traffic is added and dropped (locked) from one rotation of the ring only (provisionable). The main advantage of locked VT cross-connections is the lack of UPSR switching which results in the ability to reuse timeslots around a UPSR.
The ability to mix locked, unlocked, and pass-through VT1.5s within the same STS-1 was added in R6.0.2. In R7.0, DMX also allows both rotations of a ring to be used simultaneously.
Locked cross-connections are only used in systems that are not equipped with VLF Mains because VLF mains allow unprotected
(linear) UPSR cross-connections which allow users to independently provision cross-connections on UPSR tributaries. In systems with non-
VLF Mains, once a locked cross-connection is established from a
UPSR tributary, the companion tributary cannot be cross-connected.
...........................................................................................................................................................................................................................................................
6 - 5 8
365-372-300
Issue 8.0 September 2006
Operations, Administration, Maintenance, and Provisioning
Line Protection Switching (Line Switched Rings)
............................................................................................................................................................................................................................................................
Overview
A 2-fiber bidirectional line-switched ring (BLSR) is a self-healing ring configuration in which switching is bidirectional between each pair of adjacent nodes and is protected by redundant bandwidth on the bidirectional lines that interconnect the nodes in the ring. Because switching is bidirectional between nodes, traffic can be added at one node and dropped at the next without traveling around the entire ring.
This leaves the spans between other nodes available for additional traffic. Therefore, with distributed traffic patterns, a BLSR can carry more traffic than the same facilities could carry if configured for a unidirectional line-switched ring.
The DMX supports one high-speed OC-48 2-fiber BLSR, 2 high-speed
OC-192 2-fiber BLSRs (requires LNW59), and up to 15 low-speed
OC-48 BLSRs. In the latter application, the low-speed OC-48 BLSR is hosted by OC-48 circuit packs housed in the Function slots and can add and drop traffic with the high-speed OC-48/192 circuit packs housed in the Main slots as well as any circuit packs housed in the Function Units or Growth slots. The maximum number of 15 low-speed BLSRs requires the use of the LNW62 (4-port OC-48) pack. When the LNW62 is not used, DMX can support a maximum of 5 low-speed OC-48
BLSRs.
Self-healing rings
DMX 2-fiber BLSRs are self-healing in that transport is automatically restored after node or fiber failures. Each OC-192 line carries 96 STS-1 equivalent timeslots of working capacity plus 96 STS-1 equivalent timeslots of protection capacity. Each OC-48 line carries 24 STS-1 equivalent timeslots of working capacity plus 24 STS-1 equivalent of protection capacity. In the event of a fiber or node failure, service is restored by switching traffic from the working capacity of the failed line to the protection capacity in the opposite direction around the ring.
In the event of a node failure, traffic added and dropped from the failed node is not protected by line switching.
Protection switching
When a line failure triggers a protection switch, the nodes adjacent to the failure switch traffic on to protection capacity. Traffic heading toward the failure is looped back on to the protection capacity traveling away from the failure to reach its destination by traveling the opposite way around the ring. Service is reestablished on the protection capacity
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
6 - 5 9
Line Protection Switching (Line Switched
Rings)
Operations, Administration, Maintenance, and Provisioning
in
≤
50 milliseconds after detection of the failure (for catastrophic failures in rings without existing protection switches or extra traffic).
...........................................................................................................................................................................................................................................................
6 - 6 0
365-372-300
Issue 8.0 September 2006
Operations, Administration, Maintenance, and Provisioning
Spanning Tree
............................................................................................................................................................................................................................................................
Overview
This section provides information on the spanning tree protocol and spanning tree groups. The DMX now supports a faster spanning tree algorithm documented in IEEE 802.1w.
Important!
DMX has been designed with multi-vendor interoperobility in mind. As many vendor’s equipment (including legacy equipment) may not be able to use IEEE802.1w, DMX can automatically fall back on IEEE802.1d in the event that other NEs in the network are running standard spanning tree protocol.
However DMX employs IEEE 802.1w as a default spanning tree protocol.
Function of spanning tree
Ethernet requires a network with a tree structure in order to work effectively. Ethernet bridges and switches build tables that define the paths to specific devices. A MAC bridge, for example, will have a filtering database that defines where to send any packets addressed to a specific MAC within the network. The tables are built based on input from devices within the network.
If there is a loop in the network, that is, if there is more than one way to get to a destination device, two problems can result:
• Frames may be duplicated in the network. That is, the same frame may be sent to a node via two different paths.
• The address information will be changed as packets from that device are received across different paths. In a meshed network, the reconfiguration of the filtering database can begin to use up all the network resources, so that little bandwidth is left for data traffic.
The spanning tree accomplishes two important functions:
• It removes loops from the bridged network
• It allows reconfiguration if a link fails.
How it works
The spanning tree works as follows:
1.
Initially, every node in the group thinks it is the root node.
2.
As information about the network becomes clear, one node is designated the root node.
It is from this node that the distance to any point in the network may be measured.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
6 - 6 1
Spanning Tree
Operations, Administration, Maintenance, and Provisioning
3.
Configuration BPDUs are sent from each node to determine the most economical route from each node to the root node.
4.
Some ports are blocked so that there are no loops in the network and so that the network provides the most efficient paths from the root to the nodes.
This effectively creates a tree structure for the network.
5.
If an active link fails, the network is re configured so that previously blocked links can be used for traffic.
The following figure illustrates the spanning tree:
Figure 6-12 Spanning Tree Switch
3
4
2
5
1
Root Bridge
6 7 nc-dmx-162
Legend:
Active Links 1- 2; 2- 3; 3 -4; 5-6; 6-7; 7-1
Inactive Links 4-5
X Indicates a blocked port (no packets sent or received on this port).
Note that the configuration provides the shortest (most efficient) path from each node to the root. The configuration also provides only one path from the root node to any other node.
Re configuration
If one of the active links were broken, the network would reconfigure to allow traffic to get to the nodes. For example, if the link between 3 and 4 were broken, the link between 5 and 4 would be enabled. When the failure/break is repaired, the network will revert to the original configuration.
...........................................................................................................................................................................................................................................................
6 - 6 2
365-372-300
Issue 8.0 September 2006
Spanning Tree
Operations, Administration, Maintenance, and Provisioning
Spanning Tree on LAN ports
DMX added support for spanning tree on the LAN (customer facing) ports in R6.0. STP on LAN ports ensures that single LAN interconnects are protected. Because redundant LAN interconnects create loops, STP manages the loops. In R6.0, STP is supported on the LAN ports of the
LNW70 only.
Both LAN ports and VCGs can belong to STP groups. A LAN port can belong to only one STP group at a time. Beginning in R6.0, the BDPU
VLAN ID becomes provisionable. VLAN IDs are provisionable on a per-port basis. Prior to R6.0 all VLAN IDs were #4094
LAN based STP works exactly as described in the section above. The figure below depicts STP functioning on the customer side of a DMX with LNW70 circuit packs. The nodes marked A and B represent remote Ethernet switches or similar CPEs.
Figure 6-13 Spanning Tree on LAN ports
A
2
1
Root bridge
B
Path 1
JK-E-14.eps
Legend:
Active Links 1 to 2; 1 to B; B to A
Inactive Links A to 2
X Indicates a blocked port (frame forwarding is disabled)
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
6 - 6 3
Operations, Administration, Maintenance, and Provisioning
Resilient Packet Ring (RPR)
............................................................................................................................................................................................................................................................
Overview
DMX supports Resilient Packet Ring (RPR) Ethernet transport compliant with IEEE 802.17. RPR is intended to optimize Ethernetbased metro ring networks for packet transport with resiliency equivalent to that of SONET rings. A description of protection switching in RPR is below.
Steering Protection
DMX uses steering protection to recover from failures in RPR mode.
As shown in the figure below, all the nodes around the RPR ring learn of a failure through topology messaging. The nodes then redirect transmission to reach destination addresses. RPR steering provides <50 msec recovery time (similar to SONET) and is revertive.
Steering with Enhanced Bridging
The figure below depicts steering protection as it would function with
Enhanced RPR bridging. With enhanced bridging all nodes learn the location to which the destination address belongs and transmit packets one-way (unicast), directly toward the destination node. If packets are originating at node “x” and their destination is node “y”, and a failure occurs in the shortest path, the “x” node will perform the steering function to send packets back around the ring in the other direction.
With enhanced bridging, the post-failure transmissions will also be unicast.
Figure 6-14 Steering Protection with Enhanced Bridging
Enhanced Bridging
1 1
Y
Y
8 2
8
2
7
X
6 4
3 7
X
6
5
X
Before Steering
4
3
5
X
After Steering
MA-DMXplore-063
...........................................................................................................................................................................................................................................................
6 - 6 4
365-372-300
Issue 8.0 September 2006
Resilient Packet Ring (RPR)
Operations, Administration, Maintenance, and Provisioning
Steering with Basic Bridging (R7.0)
The figure below depicts steering protection with basic bridging. Basic bridging is supported in R7.0. Basic bridging functions using unidirectional flooding (see the graphic on the left of the figure below).
If the RPR ring is set to use basic bridging with unidirectional flooding, steering will force it into bidirectional flooding as pictured on the right side of the figure below.
Figure 6-15 Steering Protection with Basic Bridging
Basic Bridging
1 1
Y Y
8 2 8 2
3 7
X
6 4
5
X
Before Steering
(Unidirectional Flooding)
Cleave point - Based on
Failed Span
7
X
6
5
X
After Steering
(Bidirectional Flooding)
4
3
MA-DMXplore-064
As is the case with enhanced bridging, steering directs traffic away from the failure point. With basic bridging, the steering function will change the cleave point in the RPR ring to the point of failure. All traffic will still be broadcast in both directions, around the entire ring.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
6 - 6 5
Operations, Administration, Maintenance, and Provisioning
Link Aggregation (LNW70 LAN ports)
............................................................................................................................................................................................................................................................
Overview
DMX supports link aggregation on any two LNW70 LAN ports of the same rate (i.e. 100 or 1000 Mbps), operating in switched mode. In
R7.0, the two ports comprising a LAG must be located on the same pack.
Link aggregation can also provide facility protection on LNW70 LAN ports.
Hitless bandwidth increase/ decrease
Ordinarily, multiple Ethernet links between two bridges form loops
(unless a spanning tree blocks all but one) so they can’t be used to increase bandwidth. Link Aggregation causes defined groups of links to be treated as a single logical link, making multiple LAN ports appear as one. In this way, Bandwidth may be increased without requiring an upgrade to a higher rate link.
Facility protection
Link aggregation can also remove failed links automatically, thereby providing a means of facility protection. When a link fails, traffic is shifted to the remaining links in that Link Aggregation Group (LAG).
More links than are needed can be added to the group and each is active until it fails (similar to utilizing LCAS protection for SONET tributaries).
Link aggregation control protocol
Link Aggregation is specified in IEEE 802.3 clause 43, formerly specified in 802.3ad. The LNW70 can be configured to either use this standard protocol to control link aggregation (which negotiates with the equipment at the other end of the link) or to simply force aggregation without a control protocol.
...........................................................................................................................................................................................................................................................
6 - 6 6
365-372-300
Issue 8.0 September 2006
Link Aggregation (LNW70 LAN ports)
Operations, Administration, Maintenance, and Provisioning
General link aggregation rules
Link aggregation is available for LAN ports on the LNW70 pack beginning in R7.0 and behaves along the following basic guidelines:
• Available for LAN ports on the LNW70 in switched mode only
• Maximum of 4 LAGs per pack, 2 ports per LAG, and 8 LAGs per function unit or growth group. There are 8 ports on each LNW70 pack.
• The two ports in a LAG must be on the same pack, and be functioning at the same rate (i.e. 100 or 1000 Mbps).
• All links in a LAG are in-service until they fail. Standby links, providing 1x1 SONET-style protection, are a future feature.
• When a LAG is created, the attributes (VLAN, virtual switch, and other L2 provisioning) of the first port used to establish the LAG are transferred to the LAG. When the second port is added, it then inherits the L2, VLAN and Virtual Switch (VS) characteristics of the LAG for the time it remains a member. It can not be part of a
VS or have any VLAN provisioning when added.
-- Both member ports can also be added simultaneously and DMX recognizes a parameter that distinguishes the "Lead Port". The
LAG (and by association, the other port in the LAG) inherits the
L2, VLAN, and VS attributes of the Lead Port.
• When a port is removed from a particular LAG, it is no longer a member of a VS.
• A port must have L2 and VS provisioning in order for a port to be used as the Lead port or to establish a LAG (VLAN provisioning not required). This information is then transferred to the LAG once it’s created.
• The last port/member of a LAG cannot be removed from the
LAG; the LAG itself must be deleted. The last port/member of a the inherits the LAG’s L2, VLAN, and VS attributes.
-- If the last member in the LAG was the first member added originally, and if there were no subsequent changes to L2 and
VLAN attributes, the port will effectively revert to it’s original state when the LAG is deleted.
-- If the last member/port in the LAG was not the first added initially it will inherit the characteristics of the LAG rather than reverting to its original state.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
6 - 6 7
Link Aggregation (LNW70 LAN ports)
Operations, Administration, Maintenance, and Provisioning
Link Aggregation Example
The figure below depicts link aggregation on two LNW70 LAN ports functioning at 100Mbps. The top portion of the figure shows two ports receiving separate 100 Mbps inbound flows. The bottom portion depicts the same two flows being equally split across the two outbound ports in the LAG. In this example, no failure has occurred and both ports comprising the LAG are in-service.
Traffic entering incoming ports is aggregated into a LAG. While both ports are in-service, outgoing traffic is split between working ports.
Figure 6-16 Link aggregation at 100 Mbps
(all ports in-service)
Link Aggregation Group (LAG)
100 Mb
100 Mb
Up to
200 Mbps
LNW70
Link Aggregation Group (LAG)
LNW70
100 Mb
100 Mb
200 Mbps per conversation
MA-DMXAPG-044
The instance pictured above represents the ideal case, in which there are at least 2 flows, each a maximum of 100Mbps. In this case they can be equally split over the two ports comprising the LAG. The ability to split the two flows across multiple ports also depends on the distribution of MAC/IP addresses.
Link aggregation employs an algorithm that assigns traffic to member ports to prevent misreading. A given flow can be assigned to only one port and cannot be split across multiple ports in the same LAG. To increase flexibility, DMX allows a flow to be defined by either a MAC source and destination address pair or an IP source and address pair.
The algorithm uses the XOR of the least significant bits of the address
...........................................................................................................................................................................................................................................................
6 - 6 8
365-372-300
Issue 8.0 September 2006
Link Aggregation (LNW70 LAN ports)
Operations, Administration, Maintenance, and Provisioning
pairs to assign a port/link. Therefore, the actual load balancing achieved depends on the distribution of MAC/IP addresses.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
6 - 6 9
Operations, Administration, Maintenance, and Provisioning
Equipment Protection
............................................................................................................................................................................................................................................................
Overview
All transmission circuit packs are optionally 1x1 protected (not including Ethernet interfaces) and use non-revertive switching. The
ACTIVE LEDs on the 1x1 protected circuit pack faceplates show which circuit packs are carrying service. This aids technicians in circuit pack replacement procedures.
True 0x1 mode
With the introduction of the VLF Main pack (LNW59) in R7.0, DMX allows true 0x1 unprotected circuit packs. That means that tributary packs can function unprotected and any slot can be equipped with any pack (some restrictions apply). Two of the same circuit packs can also populate adjacent slots in the same group (this includes some Ethernet packs). For detailed information on circuit pack/slot equipage
restrictions in 0x1 mode, refer to
Very Large Fabric (VLF) Engineering
True 0x1 is provisionable on a per-port basis. This allows packs with multiple ports to function in mixed modes with some ports running in a protected mode (UPSR, BLSR, 1+1), while others can be 0x1 unprotected.
In order for an entire pack to be considered 0x1, allowing 2 packs of the same kind to populate adjacent slots as stated above, all ports on the pack must be provisioned for 0x1.
When tributary circuit packs are provisioned for 0x1, all provisioning, reporting and retrieval (of alarms) associated with the pack, ports and tributaries in Slot 1 are independent of the provisioning, reporting and retrieval associated with the pack, ports and tributaries in Slot 2.
When provisioned for 0x1 operation, the affect on service and severity of alarms issued against a pack in Slot 1 of a particular group are independent from the affect on service and the severity of the alarms issued against the pack in Slot 2 of that group.
Protection switching priorities
The following protection switching priorities on equipment are usercontrollable through TL1 commands:
• inhibit switch (low-speed interfaces only)
• forced switch (low-speed interfaces only)
• manual switch (low and high-speed interfaces)
If protection is not desired, interfaces can be provisioned for no protection by not equipping the adjacent Function Unit slot (for
...........................................................................................................................................................................................................................................................
6 - 7 0
365-372-300
Issue 8.0 September 2006
Equipment Protection
Operations, Administration, Maintenance, and Provisioning
socketed packs using PTMs, the corresponding socket could be unequipped), or by provisioning 0x1Sn. 0x1Sn switching can only be used on low-speed OC-n lines.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
6 - 7 1
Operations, Administration, Maintenance, and Provisioning
Performance Monitoring
Overview
............................................................................................................................................................................................................................................................
Purpose
This section lists and describes performance monitoring parameters,
SNMP traps and parameters, data storage, thresholds, and TCA transmission.
Contents
The following performance monitoring information is included in this section:
Performance Monitoring Parameters
Performance Monitoring Data Storage
Performance Parameter Thresholds
...........................................................................................................................................................................................................................................................
6 - 7 2
365-372-300
Issue 8.0 September 2006
Operations, Administration, Maintenance, and Provisioning
Performance Monitoring Parameters
............................................................................................................................................................................................................................................................
Overview
DMX uses performance monitoring (PM) to support proactive maintenance of the network and tariffed service performance verification. Proactive maintenance refers to the process of detecting degrading conditions not severe enough to initiate protection switching or alarming but indicative of an impending hard or soft failure. Hard and soft failures result in reactive maintenance. PM conditions are reported on both SONET and electrical interfaces.
Proactive maintenance
Proactive maintenance consists of monitoring performance parameters associated with the SONET sections, lines and paths within the SONET network, as well as incoming and outgoing bytes and frames on electrical (DS1/3) ports. Table 6-7, PM Parameters (6-57), lists the
SONET performance parameters monitored by DMX. These parameters are thresholded to indicate degraded performance. When a performance-monitoring threshold is crossed, it is reported to the message-based operations system where all threshold crossings associated with a particular path can be correlated, and the likely source of the degradation can be identified. Electrical performance monitoring parameters are listed later in this section.
The figure below shows DS1/DS3 line and path and DS3 path performance monitoring. DMX monitors DS3 line and path parameters from the DSX-3 and DS3 path parameters from the optical path.
Figure 6-17 DS1/DS3 Line/Path Performance Monitoring
DS1/DS3 Line, Path DS3 Path
DSX-1
DSX-3
Metropolis
®
DMX
OC-12/48/192
Input
®
DMX = Metropolis DMX Access Multiplexer
NC-DMXPM1
Section parameter
No Far-End PM parameters are defined for the Section layer. The system, as it receives SONET signals, terminates the SONET Section and Line layers and therefore is involved with Section layer PM. Section layer PM applies to optical and electrical SONET interfaces. It also applies to service and protection sections of optical sections.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
6 - 7 3
Performance Monitoring Parameters
Operations, Administration, Maintenance, and Provisioning
Line Layer
A line is a physical transport vehicle that provides the means of moving digital information between two points in a network. The line is characterized by a metallic transmission medium and its specific coding type. A line is bounded by its two end points, known as line terminations. A line termination is the point where the electrical, bipolar line signal is generated and transmitted, or received and decoded.
Path parameter
A path is a framed digital stream between two points in a network and represents digital signal transport at a specified rate, independent of the equipment and media providing the physical means of transporting the signal. A path is defined by its two end points, called path terminations, where its frame structure is generated and decoded. A path may be carried wholly within one transport segment (line), or it may span a sequential arrangement of two or more transport segments.
DS1 performance monitoring
Tariffed service verification consists of monitoring performance parameters that can be associated with the customer’s end-to-end service. The DMX system provides this capability for DS1 services with the DS1 performance monitoring feature. Based on ANSI T1.403 extended superframe format (ESF), this capability retrieves performance messages written into the ESF data link by the customer’s terminal equipment. From these messages, the DMX can determine and report the end-to-end error performance of the entire DS1 link as seen
by the customer. These parameters, listed in Table 6-7, PM Parameters
(6-57), are thresholded and reported to indicate degraded performance, and the counts are retrieved by the message-based operations system to determine if the service is operating within tariffed limits.
Application of the DS1 performance monitoring feature for tariffed service verification is shown in the figure below. This shows an ANSI
T1.403 ESF format DS1 service carried between points A and Z, using an OC-48/OC-192 system and terminated at the customer’s premises with channel service units (CSUs). At the “A” end, the received error performance, (Z - A) is detected and written by the customer CSU onto the outgoing (A - Z) ESF data link as a performance report message
(PRM). The DS1 PM circuit pack interfacing the A end reads the incoming DS1 signal’s PRM (received from the customer’s premises) and reports the Z - A performance. Likewise, the OC-48/OC-192 system interfacing the Z end reports the A - Z performance by reading the PRM from the customer’s “Z” CSU. By reviewing data from each
OC-48/OC-192 system, the service provider can determine the
...........................................................................................................................................................................................................................................................
6 - 7 4
365-372-300
Issue 8.0 September 2006
Performance Monitoring Parameters
Operations, Administration, Maintenance, and Provisioning
complete end-to-end performance (A - Z and Z - A) of the customer’s service.
DS1PM circuit pack
Additionally, each PM enabled DS1 circuit pack measures the near-end performance of the incoming DS1, allowing the service provider to determine if a good DS1 signal was received from the customer before transporting it through the network. This information can then aid in sectionalizing any reported performance problems. The circuit pack can also provide this same near-end information for super frame (SF) formatted (sometimes known as “D4 framing”) DS1 services, but complete end-to-end performance verification is limited due to the lack of the PRM in the SF format.
Figure 6-18 DS1 Path Performance Monitoring
DS1 PATH
PERFORMANCE
MONITOR
POINT B POINT C
Z-A
Performance
Report
A-B
Performance
Report
Metropolis
®
DMX
M
OC-12/48/192
DSX-1 DSX-1
Metropolis
®
DMX
M
DS1 PATH
PERFORMANCE
MONITOR
Z-A
Performance
Report
Z-C
Performance
Report
Z-A
PRM
POINT A
CSU
Network
A-Z
PRM
POINT Z
CSU
Legend:
CSU-Channel Service Unit
PRM - Performance Report Message nc-dmx2-033
DS3 performance monitoring
DMX provides DS3 performance monitoring with three DS3 path PM options: P-bit (parity bit), adjusted F&M bit (frame and multiframe bit), and C-bit.
P-Bit
When FMT is set to P-bit, P-bit errors are used as the basis for determining code violation counts. When provisioned for P-bit, the system calculates and provides counts of DS3 P-bit coding violations
(CV), errored seconds (ES), and unavailable seconds (UAS) incoming from the fiber. Quarter-hour and day registers are provided with
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
6 - 7 5
Performance Monitoring Parameters
Operations, Administration, Maintenance, and Provisioning
provisionable threshold crossing alerts (TCAs) on a per-shelf basis.
Severely errored frame seconds (SEFS) are also monitored.
Because P-bits can be corrected at nodes provisioned for VMR along a
DS3 path, the DS3 P-bit PM data may not provide a complete report of the end-to-end DS3 path errors.
Adjusted F&M Bit
When FMT is set to FM-bit, F & M bits are used as the basis for determining code violation counts. Adjusted F&M bit performance monitoring provides an alternative method for determining and accumulating DS3 path performance data based on an error estimation technique using errors on the F&M framing bits to approximate the actual error counts in the DS3 path payload. F&M bits are not corrected at nodes provisioned for VMR along a DS3 path. When provisioned for adjusted F&M bit, the system calculates and provides estimated counts of DS3 adjusted F&M bit coding violations (CV), errored seconds
(ES), severely errored seconds (SES), and unavailable seconds (UAS) incoming from the fiber.
Quarter-hour and current day registers are provided with provisionable threshold crossing alerts (TCAs) on a per-shelf basis. Severely errored frame/AIS seconds (SAS-P) are also monitored.
C-Bit
When FMT is set to cbit, C-bit errors are used as the basis for determining code violation counts.
The system provides counts of DS3 C-Bit parity coding violations (CV-
P), errored seconds (ES-P), severely errored seconds (SES-P), and unavailable seconds (UAS-P) incoming from the DSX-3 and the fiber.
The type of performance monitoring is provisioned per DS3 service by a CIT command.
For C-bit PM, the DS3 service can be provisioned in violation monitor
(VM) or violation monitor and removal (VMR) modes. In VM mode, the C-bit errors are not corrected as in the P-bit option.
Quarter-hour and day registers are provided with provisionable threshold crossing alerts (TCAs). The TCAs are provisionable on a pershelf basis. Severely errored frame seconds (SEFS) counts are also provided.
...........................................................................................................................................................................................................................................................
6 - 7 6
365-372-300
Issue 8.0 September 2006
Performance Monitoring Parameters
Operations, Administration, Maintenance, and Provisioning
Provisionable PM parameters
The table below, lists performance monitoring parameters with provisionable thresholds for SONET, Ethernet, SAN, and electrical interfaces.
Table 6-9 Provisionable PM Parameters
DS1 Path
Facility
DS1 Line
DS3 Path
DS3 Line
Parameter definition
CV-P (SF) (Coding Violation count - Path)
CV-P (ESF) (Coding Violation count - Path)
CV-PFE (ESF) (Coding Violation count - Path Far End)
ES-P (Errored Second count - Path),
ES-PFE (Errored Second count - Path Far End)
SES-P (Severely Errored Second count - Path),
SES-PFE (Severely Errored Second count - Path Far End)
UAS-P (Unavailable Second Count - Path),
UAS-PFE (Unavailable Second Count - Path Far End)
SAS-P (SEF/AIS defects Second count - Path),
SEFS-PFE (Severely Errored Frame Second count - Path Far End)
CV-L (Coding Violation count - Line)
ES-L (Errored Second count - Line),
ES-LFE (Errored Second count - Line Far End)
SES-L (Severely Errored Second count - Line)
CV-P (Coding Violation count - Path),
CV-PFE (Coding Violation count - Path Far End)
ES-P (Errored Second count - Path),
ES-PFE (Errored Second count - Path Far End)
SES-P (Severely Errored Second count - Path),
SES-PFE (Severely Errored Second count - Path Far End)
UAS-P (Unavailable Second Count - Path),
UAS-PFE (Unavailable Second Count - Path Far End)
SAS-P (SEF/AIS defects Second count - Path),
SAS-PFE (SEF/AIS defects Second count - Path Far End)
CV-L (Coding Violation count - Line)
ES-L (Errored Second count - Line)
SES-L (Severely Errored Second count - Line)
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
6 - 7 7
Performance Monitoring Parameters
E1 Path
E1 Line
Facility
STS-n Path
VT1.5 Path
VC-12 Path
Operations, Administration, Maintenance, and Provisioning
Parameter definition
BBE-P (Background Block Errors - Path),
BBE-PFE (Background Block Errors - Path Far End)
ES-P (Errored Second count - Path),
ES-PFE (Errored Second count - Path Far End)
SES-P (Severely Errored Second count - Path),
SES-PFE (Severely Errored Second count - Path Far End)
UAS-P (Unavailable Second Count - Path),
UAS-PFE (Unavailable Second Count - Path Far End)
ES-L (Errored Second count - Line)
SES-L (Severely Errored Second count - Line)
B3 SES-P (Severely Errored Second count - Path),
SES-PFE (Severely Errored Second count - Path Far End)
B3 UAS-P (Unavailable Second Count - Path),
UAS-PFE (Unavailable Second Count - Path Far End)
FC-P (Failure Counts - Path),
FC-PFE (Failure Counts - Path Far End)
B3 CV-P (Coding Violation count - Path),
CV-PFE (Coding Violation count - Path Far End)
V5 CV-P (Coding Violation count - Path),
CV-PFE (Coding Violation count - Path Far End)
V5 ES-P (Errored Second count - Path),
ES-PFE (Errored Second count - Path Far End)
V5 SES-P (Severely Errored Second count - Path),
SES-PFE (Severely Errored Second count - Path Far End)
V5 UAS-P (Unavailable Second Count - Path),
UAS-PFE (Unavailable Second Count - Path Far End)
FC-P (Failure Counts - Path),
FC-PFE (Failure Counts - Path Far End)
BBE-P (Background Block Errors - Path),
BBE-PFE (Background Block Errors - Path Far End)
ES-P (Errored Second count - Path),
ES-PFE (Errored Second count - Path Far End)
SES-P (Severely Errored Second count - Path),
SES-PFE (Severely Errored Second count - Path Far End)
UAS-P (Unavailable Second Count - Path),
UAS-PFE (Unavailable Second Count - Path Far End)
FC-P (Failure Counts - Path),
FC-PFE (Failure Counts - Path Far End)
...........................................................................................................................................................................................................................................................
6 - 7 8
365-372-300
Issue 8.0 September 2006
Performance Monitoring Parameters
Operations, Administration, Maintenance, and Provisioning
Facility Parameter definition
OC-n Line
OC-n Section
B2 ES-L (Errored Second count - Line),
ES-LFE (Errored Second count - Line Far End)
B2 SES-L (Severely Errored Second count - Line),
SES-LFE (Severely Errored Second count - Line Far End)
B2 UAS-L (Unavailable Second Count - Line),
UAS-LFE (Unavailable Second Count - Line Far End)
FC-L (Failure Counts - Line),
FC-LFE (Failure Counts - Line Far End)
PSC-L (Protection Switch Count - Line)
PSC-P (Protection Switch Count - Path)
PSC-W (Protection Switch Count - Working (BLSR only)
PSD-L (Protection Switch Duration (BLSR only)
PJCDiff-P (Count of the absolute difference between generated and detected pointer justifications - Path)
PPJC-PGen (Positive Pointer Justification Counts Generated)
PPJC-PDet (Positive Pointer Justification Counts Detected)
NPJC-PDet (Negative Pointer Justification Counts Detected)
B2 CV-L (Coding Violation count - Line),
CV-LFE (Coding Violation count - Line Far End)
B1 ES-S (Errored Second count - Section)
B1 SES-S (Severely Errored Second count - Section)
B1 CV-S (Coding Violation count - Section)
EC1 Line
SEFS (Severely Errored Frame Second count - Section)
B2 CV-L (Coding Violation count - Line),
CV-LFE (Coding Violation count - Line Far End)
B2 ES-L (Errored Second count - Line),
ES-LFE (Errored Second count - Line Far End)
B2 SES-L (Severely Errored Second count - Line),
SES-LFE (Severely Errored Second count - Line Far End)
B2 UAS-L (Unavailable Second Count - Line),
UAS-LFE (Unavailable Second Count - Line Far End)
FC-L (Failure Counts - Line),
FC-LFE (Failure Counts - Line Far End)
PJCDiff-P (Count of the absolute difference between generated and detected pointer justifications - Path)
PPJC-PGen (Positive Pointer Justification Counts Generated)
NPJC-PGen (Negative Pointer Justification Counts Detected)
PPJC-PDet (Positive Pointer Justification Counts Detected)
NPJC-PDet (Negative Pointer Justification Counts Detected)
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
6 - 7 9
Performance Monitoring Parameters
Facility
Fast Ethernet
1GE
SAN (FC-DATA pack)
Operations, Administration, Maintenance, and Provisioning
Parameter definition
EDFE (Dropped Frames - Errors (Ethernet))
EDFC (Dropped Frames - Congestion (Ethernet))
EDFE (Dropped Frames - Errors (Ethernet))
EDFC (Dropped Frames - Congestion (Ethernet))
INTXWD (Invalid Transmission Word)
Performance Monitoring
Reports
TCA summary report
The DMX provides a report that lists the number of SONET, DS1, and
DS3 performance-monitoring parameters that have crossed their thresholds. This report provides a snapshot of the system performance level. If there is signal degradation, it is quickly pinpointed so that corrective action may be taken before customers are affected, thus supporting proactive maintenance. In R4.0 threshold-crossing alerts
(TCAs) are reported on the Ethernet parameters listed in the table above.
This report provides separate parameter summaries for each signal level in the system, including SONET section, line, and path and
Electrical line and path. The parameter summaries show the user which performance status to request if they want further information.
Ethernet performance monitoring
Performance Status Reports
These reports provide detailed information on the current and previous
8 hours in quarter-hour (15-minute) increments, as well as the current and previous day’s performance. Threshold crossing alerts are clearly identified and the time the performance registers were last initialized is also shown. Any registers that may have been affected by this initialization are marked. There are separate reports for section, line, and path parameters, as well as Ethernet parameters.
DMX provides PM capabilities for the 10/100/1000T, 1G SX, and 1G
LX, 1G ZX Ethernet interfaces, and all RPR interfaces. PM data is collected at each LAN and WAN interface in the network for both incoming and outgoing directions. The WAN interface provides a connection to a SONET Virtual Concatenation Group (VCG).
For details regarding Ethernet and RPR PM and SNMP capabilities, please refer to Appendix B of this document.
...........................................................................................................................................................................................................................................................
6 - 8 0
365-372-300
Issue 8.0 September 2006
Operations, Administration, Maintenance, and Provisioning
Performance Monitoring Data Storage
............................................................................................................................................................................................................................................................
Quarter-hour and current day registers
Access/Initialization
For each parameter supported, DMX provides one current 15-minute, one current day, one previous 15-minute, one previous day, and 32 recent 15-minute accumulation and storage registers.
The DMX system can initialize these registers through the TL1 interfaces at any time, as well as retrieve and report their contents.
Beginning in R6.0, the registers are no longer initialized by a shelf restart (unless caused by a power failure).
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
6 - 8 1
Operations, Administration, Maintenance, and Provisioning
Performance Parameter Thresholds
............................................................................................................................................................................................................................................................
Provisioning
The current quarter-hour and current day thresholds for each parameter type are provisionable, on a per-shelf basis (PSD-L, FC-L, and FC-P do not have thresholds). If values other than the defaults are used, only one value for each parameter type needs to be set.
The FC-DATA packs (LNW73 and LNW73C SAN interfaces) and the
RPR Ethernet pack (LNW78) provide a different set of parameters. For more information on the parameters supported by these packs, please refer to Appendix B of this document.
Threshold crossing alerts
(TCAs)
Whenever the current quarter-hour or the current day threshold for a given parameter is exceeded, DMX generates a threshold-crossing alert
(TCA) that is entered into the performance monitoring exception report and reported to the OS through the TL1 interface.
...........................................................................................................................................................................................................................................................
6 - 8 2
365-372-300
Issue 8.0 September 2006
Operations, Administration, Maintenance, and Provisioning
TCA Transmission to OS
............................................................................................................................................................................................................................................................
Overview
The TCA information can be reported to the OS using any of the TL1
OS interfaces. TCAs can be used to trigger proactive maintenance activity.
TL1 access
The TL1 over TCP/IP OS interfaces should be used to derive full benefit from DMX’s performance monitoring capabilities. The full set of PM data stored by DMX (TCAs and the contents of PM registers) is provided through any of the TL1 interfaces.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
6 - 8 3
Operations, Administration, Maintenance, and Provisioning
SNMP Parameters and Traps
............................................................................................................................................................................................................................................................
Support of Simple Network
Management Protocol
DMX makes use of Simple Network Management Protocol (SNMP).
SNMP is the most common protocol used by data network management applications to query a management agent using a supported Management Information Base (MIB). SNMP operates at the
OSI Application layer. The IP-based SNMP is the basis of most network management software, to the extent that today the phrase
“managed device” implies SNMP compliance.
Parameters Supported
For detailed information on SNMP parameters, traps and MIBs supported by DMX, please refer to Appendix B of this document.
...........................................................................................................................................................................................................................................................
6 - 8 4
365-372-300
Issue 8.0 September 2006
Operations, Administration, Maintenance, and Provisioning
Provisioning
Overview
............................................................................................................................................................................................................................................................
Purpose
This section describes the many types of provisionable parameters available in DMX.
General
DMX allows the user to customize many system characteristics through provisioning features. Provisioning parameters are set by software controls.
Contents
The provisionable parameters described in this section include:
Automatic Provisioning on Circuit Pack Replacement
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
6 - 8 5
Operations, Administration, Maintenance, and Provisioning
Default Provisioning
............................................................................................................................................................................................................................................................
Default values
Installation provisioning is minimized with thoughtfully chosen default values set in the factory. Every parameter has a factory default value.
These factory defaults for software parameters are maintained in the
SYSCTL circuit pack, and a single command is provided to restore all default values. The original values assigned at the factory cannot be changed. However, the current values can be overridden through local or remote provisioning.All provisioning data is stored in nonvolatile memory to prevent data loss during power failures and maintenance operations.
A parameter is a characteristic of the system that affects its operation.
The parameter value may be a number, text string, or other menu selection.
...........................................................................................................................................................................................................................................................
6 - 8 6
365-372-300
Issue 8.0 September 2006
Operations, Administration, Maintenance, and Provisioning
Remote Provisioning
............................................................................................................................................................................................................................................................
Overview
Software control allows remote provisioning of DMX NEs. This feature is provided especially for provisioning parameters likely to change in service, in support of centralized operations practices.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
6 - 8 7
Operations, Administration, Maintenance, and Provisioning
Cross-Connect Provisioning
............................................................................................................................................................................................................................................................
Overview
The DMX can be provisioned for signal routing. Depending on the application, VT1.5, STS-1, STS-3(c), STS-12(c), or STS-48(c) signal cross-connections may be established to route traffic in a specific manner. Cross-connections may be bidirectional or unidirectional.
Beginning in R6.0 and going forward, DMX employs atomic crossconnections for all cross-connect provisioning. Atomic crossconnections are one-way cross-connections between logical ring channels which can be set up and taken down by a single command, and which cannot be broken down into smaller parts. Logical ring channels are the tributaries of a port or port protection group used for transmission in the absence of any line or equipment protection.
Atomic cross-connections are more flexible than the cross-connect provisioning structure employed previously. They allow for the support of more detailed applications because you are able to provision each portion of a cross-connection.
Typical cross-connections
Any VT1.5 or STS-n signal may be provisioned for the following signal routes:
• Main to Main
• Main to Function Unit.
• Hairpin (Function Unit to Function Unit).
DMX supports unidirectional cross-connections.
STS-1 cross-connections to Ethernet interfaces are also available. The
1WAY and 1WAYPR cross-connection is used for UPSR point-to-point
Ethernet applications. A 1WAY UNSWITCHED cross-connect is used for multipoint Ethernet applications.
The unidirectional pass-through cross-connect is used to pass VT1.5 or
STS-n signals through the NE all on the same timeslot. For passthrough cross-connects, the channel state default is NMON rather than
AUTO as with other cross-connects.
For more info
For more information on cross-connections, refer to Chapter 5,
“System Planning and Engineering.”
...........................................................................................................................................................................................................................................................
6 - 8 8
365-372-300
Issue 8.0 September 2006
Operations, Administration, Maintenance, and Provisioning
Automatic Provisioning on Circuit Pack Replacement
............................................................................................................................................................................................................................................................
Overview
Replacement of a failed circuit pack is simplified by automatic provisioning of the original circuit pack values. The SYSCTL circuit pack maintains a provisioning map of the entire shelf. Prior to R6.0, when a transmission pack was replaced, the SYSCTL (LNW1) circuit pack automatically downloaded the correct values to the new circuit pack. Likewise, when the LNW1 circuit pack was replaced, the correct provisioning data from every other circuit pack in the shelf was automatically uploaded to the new SYSCTL circuit pack's nonvolatile memory.
Beginning in R6.0, the provisioning map for the entire shelf is stored redundantly within the SYSCTL (LNW2). Therefore is does not need to be uploaded from other packs. In order to replace the LNW2, the user removes the NVM from the old LNW2 and places it in the new
LNW2. Alternatively, the user may backup the database, install a factory-fresh LNW2 (with new NVM cards), enter maintenance mode, download the generic, and restore the database.
Auto provisioning
Auto provisioning is the ability of an NE to detect the presence of equipment, validate it, and then assign default original values or preprovisioned parameter values to new equipment. Nonvolatile memory
(NVM) and/or hardware registers maintain the parameter values. If you have predefined or pre-provisioned some or all of the parameters, the auto provisioning function validates the request and assigns the preprovisioned values or default values as required. Auto-provisioning allows an NE to be set up initially with minimal user intervention.
Auto-provisioning also supports a self inventory function which allows operations center personnel to learn about and track activities at a remotely located NE.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
6 - 8 9
Automatic Provisioning on Circuit Pack
Replacement
Operations, Administration, Maintenance, and Provisioning
Automatic provisioning on circuit pack replacement
Replacement of a failed circuit pack is simplified by automatic provisioning of the original circuit pack values. The SYSCTL circuit pack maintains a provisioning map of the entire shelf. Prior to R6.0, when a transmission pack was replaced, the SYSCTL (LNW1) circuit pack automatically downloaded the correct values to the new circuit pack. Likewise, when the LNW1 circuit pack was replaced, the correct provisioning data from every other circuit pack in the shelf was automatically uploaded to the new SYSCTL circuit pack's nonvolatile memory.
Beginning in R6.0, the provisioning map for the entire shelf is stored redundantly within the SYSCTL (LNW2). Therefore is doesn’t need to be uploaded from other packs. In order to replace the LNW2, the user removes the NVM from the old LNW2 and places it in the new LNW2.
Alternatively, the user may backup the database, install a factory-fresh
LNW2 (with new NVM cards), enter maintenance mode, download the generic, and restore the database.
Items auto provisioned
Some items that are auto-provisioned include the following:
• System target identifier (TID) (which can be changed at initial start-up)
• Default threshold-crossing alert (TCA) profiles
• Circuit packs
• Synchronization default mode
Equipment removal
The NE detects and reports the removal of equipment. The removal of equipment does not cause the NE to delete any entities. Removal of a piece of equipment may result in equipment alarms and insertion of maintenance signals when the state related data is updated. However, removal of equipment does not necessarily mean that the provisioning of the shelf slot has changed. The user must execute specific commands to remove an entity from the system database.
...........................................................................................................................................................................................................................................................
6 - 9 0
365-372-300
Issue 8.0 September 2006
Operations, Administration, Maintenance, and Provisioning
Port State Provisioning
............................................................................................................................................................................................................................................................
Overview
Port state provisioning is a feature provided on DMX NEs that can help suppress alarm reporting and performance monitoring by supporting multiple states for DS1, DS3, E1, EC-1, and Ethernet LAN ports.
The states supported are as follows:
• automatic (OOS-MA-AS)
• in-service (IS)
• not monitored (OOS).
Ethernet states supported are as follows:
• automatic (AUTO)
• in-service (IS)
• not monitored (NMON).
Port states
Ports without signals (undriven) are in the automatic state until changed to the in-service state. Ports are changed to the in-service state when a signal is present or they can be provisioned as in-service by the user. Commands allow a user to retrieve and change the state of a port to the not-monitored state or from the not-monitored state to the automatic state.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
6 - 9 1
Operations, Administration, Maintenance, and Provisioning
Channel State Provisioning
............................................................................................................................................................................................................................................................
Overview
Automatic channel state provisioning is a capability provided on DMX
NEs that suppresses reporting of transient alarms and events during provisioning by supporting multiple states (see previous section) for
VT1.5, VC-12, STS-1, STS-3(c), STS-12(c), STS-48(c) channels.
Automatic channel state provisioning
While an end-to-end circuit is being set up, particularly during VT1.5/
VC-12 and STS-n cross-connect provisioning, several transient maintenance signals result. Without automatic channel state provisioning, these are reported as alarms and events. The technicians are expected to ignore these transient alarms and initiate corrective action only if the alarms persist after the provisioning is completed. To avoid the confusion created by this, DMX provides automatic channel state provisioning.
Channel states
A VT1.5 or STS-n channel is kept in the default automatic (OOS-MA-
AS) state until the reception of a valid signal (for STS channel states, a valid signal is one free of LOP-P, AIS-P, UNEQ-P, and SF-- for VT channel states, a valid signal is one free of LOP-V, AIS-V, and UNEQ-
V.) in that channel. While in OOS-MA-AS state, no alarms or events are reported on the channel. On receiving a valid signal, which occurs when the end-to-end circuit is completely provisioned, the channel automatically changes to the in-service (IS) state, where it resumes normal alarm and event reporting. An additional state, not-monitored
(OOS), is also supported in which alarm and event reporting is suppressed regardless of the validity of the signal being received on the channel. Like the port state provisioning capabilities already provided for physical ports like DS1, DS3, and EC-1, the user can submit commands to manually change a channel from IS or OOS-MA-AS to
OOS, and from OOS to OOS-MA-AS. A user cannot manually change from OOS-MA-AS or OOS to IS.
Note that for pass-through cross-connects, the channel state transitions from OOS-MA-AS to OOS upon receiving a good signal. This is different than what happens on dropped tribs. On dropped tribs, the channel state automatically transitions from OOS-MA-AS to IS upon receiving a good signal.
...........................................................................................................................................................................................................................................................
6 - 9 2
365-372-300
Issue 8.0 September 2006
Channel State Provisioning
Operations, Administration, Maintenance, and Provisioning
Note on LOP-P
LOP-P is reported regardless of channel state. STS LOP (LOP-P) is reported on any cross-connected tributary, even when the STS channel state is OOS-MA-AS or OOS. For BLSR, LOP-P is also reported on all working and protection tribs, independent on whether or not there is a cross-connect.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
6 - 9 3
Operations, Administration, Maintenance, and Provisioning
Line State Provisioning
............................................................................................................................................................................................................................................................
Overview
The state of the low-speed OC-3/12/48 and the high-speed OC-12/48/
192 ports can be set manually to OOS. On OLIUs with multiple ports, the line state default is OOS-MA-AS. In R7.0, it also becomes possible to manually provision any equipped line to IS (in-service)
Refer to the previous section of this chapter entitled Port State
Provisioning (6-91) for more information about the AUTO line state.
...........................................................................................................................................................................................................................................................
6 - 9 4
365-372-300
Issue 8.0 September 2006
Operations, Administration, Maintenance, and Provisioning
Reports
Overview
............................................................................................................................................................................................................................................................
Purpose
This section describes reports generated by DMX.
Contents
Reports described in this section include:
Performance Monitoring Reports
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
6 - 9 5
Operations, Administration, Maintenance, and Provisioning
Alarm and Status Reports
............................................................................................................................................................................................................................................................
Overview
The system provides alarm reports that list the active alarm and status conditions, including a remote alarm/status feature that summarizes alarms in other NEs in an alarm group. A description of the condition
(for example, controller failure, incoming high-speed signal failure, synchronization hardware or reference failure, etc.) is included in the reports along with a time stamp indicating when the condition was detected, its severity, and whether it is service affecting or not. The option to display specified subsets of alarm conditions is provided (for example, critical alarms only).
Circuit Pack Status conditions
Circuit pack status conditions include:
• Manually initiated abnormal conditions (for example, forced switch, manual lockouts, loopbacks, system testing)
• Incoming AIS detected
• ACO active.
A description of the status condition (for example, DS1 loopback active, DS3 facility loopback active, etc.) is included in the report along with a time stamp indicating when the condition began.
DMX began support of Alarm Severity Assignment Profiles (ASAPs) in R6.0. With ASAPs, any alarm supported for a particular circuit pack/ interface can now be a status condition as well.
...........................................................................................................................................................................................................................................................
6 - 9 6
365-372-300
Issue 8.0 September 2006
Operations, Administration, Maintenance, and Provisioning
Performance Monitoring Reports
............................................................................................................................................................................................................................................................
TCA summary report
DMX provides a report that lists the number of SONET performancemonitoring parameters that have crossed their thresholds. This report provides a snapshot of the system performance level. If there is signal degradation, it is quickly pinpointed so that corrective action may be taken before customers are affected, thus supporting proactive maintenance.
This report provides separate parameter summaries for each signal level in the system, including SONET section, line, and path, as well as dropped/incoming/outgoing Ethernet bytes and frames. The parameter summaries show the user which performance status to request if they want further information.
Performance status reports
These reports provide detailed information on the current and previous
8 hours in quarter-hour (15-minute) increments, as well as the current and previous day’s performance. Threshold crossing alerts are clearly identified and the time the performance registers were last initialized is also shown. Any registers that may have been affected by this initialization are marked. There are separate reports for section, line, and path parameters, as well as Ethernet parameters.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
6 - 9 7
Operations, Administration, Maintenance, and Provisioning
Maintenance History Reports
............................................................................................................................................................................................................................................................
Overview
A maintenance history report contains the following past conditions:
• alarms
• status
• protection switching
• user interface commands (e.g., provisioning, loopback request, manual protection, etc.)
Summary
The maintenance history report contains time stamps indicating when each condition was detected and when it cleared, as well as when the command was entered. Note that beginning in R6.0, any system controller (SYSCTL) reset no longer clears all records in the log. The
LNW2 contains removable NVM memory cards that store these logs.
Reference
See the DMX Access Multiplexer User Operations Guide, 365-372-
301, for details on the history log.
...........................................................................................................................................................................................................................................................
6 - 9 8
365-372-300
Issue 8.0 September 2006
Operations, Administration, Maintenance, and Provisioning
State Reports
............................................................................................................................................................................................................................................................
Overview
The state report shows the protection state of all circuit packs installed in the system and the state of the individual low/high-speed channels.
Circuit pack states
The circuit pack state is reported as “active” or “standby.”
Path states
The state of the individual VT1.5/VC-12 /STS-n channels and paths may be one of the following:
• not monitored (NMON)
• in service (IS)
• auto (AUTO).
The system reports this information on all interfaces. For VT1.5/VC-
12/STS-n channels and paths, the AUTO state would transition to the
IS state if a good signal is detected.
Port states
The state of individual ports, including those contained in multiport circuit packs (DS1/E1, DS3/EC-1, Ethernet interface packs, quad
OC-3, dual and quad OC-12, or OC-48), may be NMON, IS, or AUTO.
Line states
The state of individual lines may be IS, NMON, or AUTO for all OC-n ports.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
6 - 9 9
Operations, Administration, Maintenance, and Provisioning
Provisioning Reports
............................................................................................................................................................................................................................................................
Overview
The DMX provides a variety of provisioning reports that contain the current values of all electronically-provisionable parameters. For more information on the provisioning reports generated, refer to the DMX
Access Multiplexer User Operations Guide, 365-372-301.
...........................................................................................................................................................................................................................................................
6 - 1 0 0
365-372-300
Issue 8.0 September 2006
Operations, Administration, Maintenance, and Provisioning
Version/Equipment List
............................................................................................................................................................................................................................................................
Overview
The DMX system provides a full inventory report on all hardware and software currently installed.
Information provided
The version/equipment list provides the following information relative to circuit packs:
• Circuit pack name
• 10-character CLEI code
• 6-digit equipment catalog item (ECI)
• 10-character apparatus code
• 6-character series number
• 12-character serial number (includes date and location of manufacture)
• Program version (software generic) code
• Program versions in dormant area.
The version/equipment list provides the following information relative to pluggable transmission modules (PTMs):
• Comcode
• CLEI code
• Date of manufacture
• 10-character apparatus code
• 6-character series number
• 12-character serial number (includes date and location of manufacture)
• Manufacturer identifier
• Module name
• Module product ID
• Reach (i.e. short, intermediate, long)
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
6 - 1 0 1
Operations, Administration, Maintenance, and Provisioning
Administration
Overview
............................................................................................................................................................................................................................................................
Purpose
This section provides information on system administration.
Contents
System administration considerations included in this section are:
IP Access for network management
Password Administration (CIT and System)
User-setable Miscellaneous Discrete Interface
...........................................................................................................................................................................................................................................................
6 - 1 0 2
365-372-300
Issue 8.0 September 2006
Operations, Administration, Maintenance, and Provisioning
Software Upgrades
............................................................................................................................................................................................................................................................
Overview
DMX provides an in-service software installation capability to update the generic program in local and remote systems. Upgrades are distributed on CD-ROMs containing the new software and an installation program. These software upgrades are the primary mechanism to add new feature enhancements to the in-service DMX network.
Beginning in R6.0, DMX employs provisionable alarm severity profiles known as ASAPs. Therefore, previous alarm severity level provisioning is lost when upgrading to R6.0. Also, because R6.0 introduces atomic cross-connections, any existing 2WAY, 2WAYPR, and MLTPT cross-connects will be automatically replaced with equivalent 1WAY, 1WAYPR, and UNSWITCHED cross-connects.
Prior to R6.0, all in-service software upgrades did not affect any provisionable parameters. For example, cross-connections were left unchanged by the software upgrade.
Software download
In the DMX system, software download takes place in two stages. In the first stage, the new generic software is downloaded into a dormant
“flash” area as a compressed file. In the second stage, the new generic is uncompressed and moved into an active “flash” space. During this process, the old release continues to run from random access memory
(RAM). Installation is not service-affecting, so down time is limited to the reboot time.
Local installation procedure
The procedure is straightforward. The technician connects a personal computer (PC) to the IAOLAN port on the local DMX, starts the installation program, and is prompted with a few warnings before the upgrade installation actually begins. After the technician confirms to proceed, the PC takes over the process and completes the installation.
Installation may also be performed via Lucent’s Navis OMS or PC-CIT over the IAO LAN interface using FTP or FTAM. For more information on software download and upgrade via Navis OMS, refer to the Subnetwork Management System (SNMS) User Guide, 190-224-
100.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
6 - 1 0 3
Operations, Administration, Maintenance, and Provisioning
IP Access for network management
............................................................................................................................................................................................................................................................
Overview
For network management purposes, the DMX supports the following types of IP Access:
• DMX can serve as a TL1 Translation Device (T-TD) by acting as a gateway network element that allows Navis
®
Optical EMS and/or
WaveStar
®
CIT to communicate to other network elements (NEs) through an IP access network. This capability allows you to send
TL1 commands from Navis
®
Optical EMS or WaveStar
®
CIT located on a TCP/IP based network to various NEs connected on an OSI network.
• DMX can functionally encapsulate IP packets within OSI packets to be transmitted through the OSI network to the proper NE. Thus
DMX supports IP based protocols such as FTP by providing endto-end IP connectivity between OS and NE. This capability is called IP tunneling. IP tunneling is required to support remote database backup/restore in between DMX systems.
• DMX can also serve as a File Transfer Translation Device (FTTD) by acting as an FTAM-FTP gateway network element. The
FTAM-FTP gateway network element translates FTAM over OSI presentation to FTP over TCP/IP. The FTAM-FTP gateway supports software downloads, database backups, and database restores.
• DMX also supports Simple Network Management Protocol
(SNMP). DMX provides limited support for certain reports and traps (alarms and events autonomous messages).
• DMX also supports Network Time Protocol (NTP) using IP tunneling to synchronize the time and date to a standard time reference.
...........................................................................................................................................................................................................................................................
6 - 1 0 4
365-372-300
Issue 8.0 September 2006
IP Access for network management
Operations, Administration, Maintenance, and Provisioning
TL1 Translation
The DMX can copy the application information within an IP packet into an OSI packet. This translation is performed at the application layer. When acting as a TL1 translation device, the DMX system must be provisioned with a list of possible OSs. If an OS is not on the list residing within the system, a connection from that OS will not be accepted. When the DMX is used as a TL1 translation device it is referred to as the T-TD GNE (Gateway Network Element). The T-TD
GNE provides the same functionality as the NCC TL1 TCP/IP gateway.
Figure 6-19 TL1 Translation Device
WaveStar
®
CIT
Navis
TM
Optical
EMS
TCP/IP
TL1
TCP/IP
TL1
TCP/IP
WAN
OSI
DMX
TCP/IP
TL1
T-TD GNE
IP to OSI
Translation
OSI
DMX or
Compatible
NE
OSI
OC-48/OC-192
BLSR or
UPSR
DMX or
Compatible
NE
DMX or
Compatible
NE
OSI nc-dmx-097
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
6 - 1 0 5
IP Access for network management
Operations, Administration, Maintenance, and Provisioning
IP Tunneling
Today, Telecom networks mix a wide range of heterogeneous protocols and applications.
The Lucent IP tunneling solution consists in encapsulating IP packets inside CLNP (ISO 8473 ConnectionLess Network Protocol) PDU, in order to be able to use an existing OSI-based embedded Data
Communications Network (DCN) for IP traffic.
With the IP tunneling over CLNP solution, the DMX NE can support the following two customer applications: IP access and IP fringe.
An IP access application is shown in Figure 1, where an IP based OS
(for example, SNMP manager) located in the IP access DCN manages a remote DMX NE located in the OSI-based embedded DCN. The IP application initiated at the OS terminates at the remote NE.
Figure 6-20 IP Tunneling
Navis
TM
Optical
EMS
FTP/IP
WaveStar
®
CIT
FTP/IP
TCP/IP
WAN
OSI
FTP/IP
DMX
IP
Tunneling
GNE
OSI
DMX or
Compatible
NE
OC-48/OC-192
BLSR or UPSR
DMX or
Compatible
NE
OSI
DMX or
Compatible
NE
OSI
- FTP through IP Tunnel
GNE - GateWay Network Element nc-dmx-098
An IP fringe application, where an IP based OS located in the IP access
DCN manages an IP managed NE (non DMX) on the fringe of DMX
OSI-based embedded DCN. The IP application initiated at the OS
...........................................................................................................................................................................................................................................................
6 - 1 0 6
365-372-300
Issue 8.0 September 2006
IP Access for network management
Operations, Administration, Maintenance, and Provisioning
terminates at the IP managed NE. Note that if the IP managed NE is not directly connected to the DMX remote NE via the
LAN, but can be reached via additional routers, some static routes have to be provisioned manually on the routers.
Encapsulating IP Packets
The DMX GNE acts as the tunnel entrance, i.e., the interface between
IP and CLNP. When an IP packet is received from the LAN interface of the GNE, if it is not destined for the GNE, the received IP packet is encapsulated into CLNP PDU(s) as simple CLNP user data, loosing any IP protocol meanings (such as IP addressing and life time), as shown in the figure below.
Figure 6-21 Encapsulated IP Packets
IP Packet
IP Header User Data
Encapsulated
CLNP Header IP Header User Data
Encapsulated and
(if necessary)
Segmented
CLNP Header IP Header
User Data
CLNP Header IP Header
User Data
For the CLNP PDU that contains the encapsulated IP packet, the CLNP source address is the NSAP of the NE where the IP packet is encapsulated (tunnel entrance), and the CLNP destination address is the
NSAP of the NE where the IP packet will be de-capsulated (tunnel exit). The CLNP PDU then is routed via the ISO-10589 “IS to IS intradomain information exchange protocol (IS-IS)” within the embedded
OSI DCN. Therefore, the IP tunneling over CLNP is transparent for the
IP world. The CLNP world is only used to carry the IP traffic and there is no possible connections between the OSI applications and the IP applications. The IP tunnel serves as a normal point-to-point link for the IP traffic between two NSAP entities (the tunnel entrance and tunnel exit). Note that because the IP traffic flows in both directions between two NSAP entities, the tunnel entrance entity also serves as the tunnel exit entity, and vice versa.
In the tunnel entrance, the way to associate an IP destination address in the IP packet with an OSI NSAP address (the NSAP of tunnel exit entity) can be derived by the static user provisioned information or by the automatic distributed tunnel routing information, called Tunnel
Auto Provisioning (TAP).
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
6 - 1 0 7
IP Access for network management
Operations, Administration, Maintenance, and Provisioning
Tunnel Auto Provisioning (TAP)
In the OSI networks, the network elements use the ISO-10589 “IS to IS intra-domain information exchange protocol (IS-IS)” to exchange the topology information. The knowledge by every network element of the whole network topology at a given time allows the computation of the optimal route to any possible destination on the network. The IS-IS protocol provides for the inclusion of optional variable length fields in all IS-IS packets. This allows additional IP specific information to be added to the OSI IS-IS routing packets.
The topological information between network elements (or called intermediate systems) is communicated by sending a specific IS-IS
PDU called LSP (Link-State PDU). In the LSP optional fields, the NEs send (advertise) information about the IP subnets that can be reached via that NE. By default, this will be locally attached subnet, but other subnets can also be provisioned for the advertisement.
The advertising of IP information using the LSP options can be enabled or disabled via the user interfaces. Based on the specification of the IS-
IS protocol, any intermediate systems that could not recognize the encoded optional fields shall just ignore and pass through these fields unchanged. This makes it possible that the NEs that advertise both OSI and IP routing information can seamlessly interwork with the NEs that advertise the OSI routing information only.
With automatic distribution of IP routing information via IS-IS LSP, a
NE, which learned such information, then can associate an IP destination address of an IP packet with an OSI NSAP address, and uses this NSAP address as the destination address of CLNP PDU(s) which encapsulates the IP packet.
...........................................................................................................................................................................................................................................................
6 - 1 0 8
365-372-300
Issue 8.0 September 2006
IP Access for network management
Operations, Administration, Maintenance, and Provisioning
FTAM-FTP gateway network element
DMX can serve as a File Transfer Translation Device (FTTD) by acting as an FTAM-FTP gateway network element. The FTAM-FTP gateway network element translates FTAM over OSI presentation to FTP over
TCP/IP. The FTAM-FTP gateway supports software downloads, database backups, and database restores.
The figure below shows a DMX provisioned as an FTAM-FTP gateway network element. The FTAM-FTP gateway network element allows remote DMX network elements to request software downloads and database restores from an FTP server. The FTAM-FTP gateway network element also allows remote DMX network elements to backup databases to an FTP server.
Figure 6-22 FTAM-FTP Gateway
FTP
Server
TCP/IP
TCP/IP
WAN
TCP/IP
DMX
FTAM-FTP
GateWay
OSI OSI
DMX or
Compatible
NE
OC-48/OC-192
BLSR or
UPSR
DMX or
Compatible
NE
OSI
DMX or
Compatible
NE
®
DMX = Metropolis DMX Access Multiplexer
OSI nc-dmx-243
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
6 - 1 0 9
IP Access for network management
Operations, Administration, Maintenance, and Provisioning
IP over DCC
The sections above described how DMX can act as a GNE providing
FTTD and TTD functionality. If there is no DMX in a particular office where GNE can connect, via IAO LAN interface, to the IP WAN, these options can prove ineffective. For this reason R5.1 incorporates IP communications over the DCC channel. This feature allows operations communications to flow through another device (like Ciena Core
Director) to the DMX GNE via an IP over DCC link. This feature also enables interworking with Ciena Core Director (CD).
Management Traffic Flow (OMS to DMX)
OMS originates IP packets destined to DMX GNE, and uses Router R1 as the Default Router. Router R1 routes the packets via IP access DCN to Router R2. Router R2 forwards the packets to CD via Proxy ARP supported by CD. Based on the static routing, CD forwards the IP packets to DMX GNE via IP over DCC link. DMX GNE translates IP messages to OSI messages and routes CLNP packets to the remote NE
(RNE) via OSI embedded DCN.
Management Traffic Flow (DMX to OMS)
DMX RNE originates CLNP packets destined to DMX GNE, and routes CLNP packets to DMX GNE via OSI embedded DCN. The
DMX GNE translates OSI messages to IP messages, and originates IP packets destined to OMS. Based on static routing, the DMX GNE uses the IP over DCC link to forward the IP packets to the CD. CD forwards the IP packets to Router R2 via default routing provisioned by user.
Router R2 routes the IP packets via IP access DCN to Router
R1.Router R1 forwards the IP packets to OMS.
The figure below depicts the functionality of IP over DCC.
Figure 6-23 Operations Communication via IP over DCC
Telcordia
OMS
IP
Router 1
TCP/IP
WAN
Router 2
DMX
RNE
OSI
Ciena
Core
Director
IP over DCC
DMX
GNE
OC-12/48/192
BLSR or UPSR
OSI
GNE - GateWay Network Element
RNE - Remote Network Element
®
DMX = Metropolis DMX Access Multiplexer
DMX
RNE
OSI
DMX
RNE
OSI
...........................................................................................................................................................................................................................................................
6 - 1 1 0
365-372-300
Issue 8.0 September 2006
Operations, Administration, Maintenance, and Provisioning
Time and Date Synchronization
............................................................................................................................................................................................................................................................
Overview
Synchronizing the time and date among all NEs in a network is useful to correlate events reported by different NEs.
The time and date is synchronized:
• Manually using the WaveStar
®
CIT
Administration > Set Date and
Time
command.
• Automatically from another NE via the DCC.
• Automatically by the OS
Provisioning
In a new installation, it is recommended that the time and date be manually provisioned in at least the first DMX in each ring. Each subsequent DMX that is added to the network tries to learn the current time and date from one of the existing NEs automatically.
After start-up (or any subsequent controller resets), the DMX's time and date revert back to the last time and date before the reset. DMX waits 5 minutes, in case other NEs are also resetting (for example, as part of a software upgrade of the network), before starting to check with other NEs for the current time and date. If necessary, the DMX checks with all remote NEs for the current time and date.
The DMXs allow up to 2 minutes for each remote NE to respond before checking with the next remote NE for the current time and date, and keep checking until a valid current time and date is found.
The DMX accepts a provisioned time and date value or any remote NE date later than
00-01-01
as a valid current time and date.
Network Time Protocol
Network Time Protocol (NTP) assures accurate synchronization of the
DMX with reference to radio and/or atomic clocks located on the
Internet.
Considerations
The automatic time and date synchronization is intended to achieve time and date synchronization among compatible NEs with DCC connectivity in a network, but such synchronization can not be guaranteed at start-up for all network configurations or over the course of time.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
6 - 1 1 1
Time and Date Synchronization
Operations, Administration, Maintenance, and Provisioning
TL1 command responses and autonomous messages include DMX’s current time and date. As an alternative to manually provisioning and confirming the current time and date in each DMX in a network,
Navis™ Optical Element Management System, (formerly SNMS), automatically checks the current date and time, periodically or ondemand.
Time and date synchronization compatibility
The following table lists DMX Time and Date Synchronization compatibility with other products.
Table 6-10 DMX Time and Date Synchronization Compatibility
Products
DMX
Metropolis
®
DMX
Metropolis
®
DMXplore
Metropolis
®
DMXpress
Metropolis
®
DMXtend
DDM-2000 OC-3
DDM-2000 OC-12
FiberReach
FT-2000 ADR
DMX
yes yes yes yes yes yes yes yes yes
...........................................................................................................................................................................................................................................................
6 - 1 1 2
365-372-300
Issue 8.0 September 2006
Operations, Administration, Maintenance, and Provisioning
Office Alarms Interface
............................................................................................................................................................................................................................................................
Description
The office alarms interface is a set of discrete relays controlling audible and visible office alarms. Relays are provided for the following types of alarm conditions:
• CR (critical)
• MJ (major)
• MN (minor)
If desired, critical and major alarm outputs can be wired so that either, neither, or both of the outputs control the major office alarm.
Steady state current
The steady state current for office alarm connections must not exceed
1.0 Amp at 60 Volts or 1.8 Amps at 30 Volts. The maximum transient currents (20 msec duration) during initial contact closure must not exceed 9 Amps at 60 Volts or 18 Amps at 30 Volts.
Provisionable alarm delay and alarm clear delay
DMX provides provisionable incoming signal alarm delay and alarm clear delay. The office alarms are not activated unless an incoming signal condition of greater duration than the alarm delay occurs. When a failure clears, a provisionable alarm clear delay prevents premature clearing of the alarm.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
6 - 1 1 3
Office Alarms Interface
Operations, Administration, Maintenance, and Provisioning
Multiple alarms
When multiple alarm conditions occur, the highest-level office alarm
(audible and visible) is activated. When the highest-level alarm condition clears, the office alarm “bumps down” to the next highest level alarm condition.
If enabled, the Remote NE Status feature includes alarms at other NEs in the same alarm group as the local NE to determine when to activate the local office alarm and the appropriate alarm level.
Alarm cut-off
The audible office alarms are silenced through activation of the alarm cut-off (ACO) function. Visible alarms are not extinguished by the
ACO function.
If the ACO function has been activated to silence the active audible alarm and a “bump down” occurs, the audible alarm remains silent (that is, the lower level visible alarm is activated, but the corresponding audible alarm is not reactivated). If another alarming condition occurs while the ACO is active, the highest level audible alarm is activated even if the new condition is a lower level. For example, if a major (MJ) alarm was active and silenced using the ACO function and a minor
(MN) alarming condition occurs, the MJ audible alarm will sound.
...........................................................................................................................................................................................................................................................
6 - 1 1 4
365-372-300
Issue 8.0 September 2006
Operations, Administration, Maintenance, and Provisioning
Remote NE Status
............................................................................................................................................................................................................................................................
Overview
If enabled, the Remote NE Status feature reflects the summary alarm/ status level for both the local and remote NEs in the same alarm group as the local NE with the following local indications.
Office alarms
The local office visual alarm always shows the highest alarm level. The local office audible alarm is activated in response to each new alarm occurrence among the local and remote NEs. Thus alerting on-site craft of problems in the network with an indication of the severity.
SYSCTL faceplate LEDs
The CR, MJ, or MN LED on the local SYSCTL circuit pack faceplate shows the highest alarm level among the local and remote NEs. The FE
LED on the local SYSCTL circuit pack faceplate is illuminated if any remote NE has an active alarm, abnormal status (indicated by the ABN
LED), or “activity” status condition, thus identifying the local NE to query further. (Although not dependent on the Remote NE Status feature, the Near-End LED on the local SYSCTL circuit pack faceplate is only illuminated if the local NE itself has an active alarm, abnormal status, or “activity” status condition.)
Remote NE status and alarm/status retrieval
The local NE can retrieve the highest alarm/status level of each NE in a network with an active alarm, abnormal status, or “activity” status condition, thus identifying the remote NE to further query.
Determination of the highest alarm/status level of each NE includes the alarm/status level of active miscellaneous discrete alarm/status inputs.
The Remote NE Status feature can be used to expedite maintenance activities for NEs that report TL1 autonomous alarm/status messages to a maintenance OS at an operations center.
The Remote NE Status feature may be enabled or disabled. By default, the Remote NE Status feature is disabled.
Alarm group
By default, all DMX systems are assigned to alarm group 255. This is typically sufficient for small networks of up to 50 nodes. All NEs with
DCC connectivity that have the same alarm group number are members of the same alarm group. All alarm group members share summary alarm/status information with each other but not with NEs in different alarm groups. To take advantage of the remote activation of local office alarms, in particular, at least one member of the alarm group should be located in a central office.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
6 - 1 1 5
Remote NE Status
Operations, Administration, Maintenance, and Provisioning
In large networks, with IS-IS Level 2 Routing and multiple Level 1 areas, each alarm group must be confined to within a single Level 1 area only. For example, a network with three different Level 1 areas would require a minimum of three alarm groups, that is, one alarm group for each Level 1 area. If desired, multiple alarm groups can be defined within a Level 1 area, also. The maximum number of NEs in an alarm group is limited by the maximum number of nodes in a Level 1 area.
Alarm gateway NE (AGNE)
By default, no NE is enabled as an AGNE. Even if the default alarm group number for all NEs is used, at least one NE in each alarm group must be enabled as an AGNE. Any NE in an alarm group can be enabled as an AGNE, for example, an AGNE does not need to be located in a central office, in fact, it is recommended that an AGNE should not also be a TL1 TCP/IP GNE or IS-IS Level 2 Router.
A second NE in each alarm group may be enabled as a backup AGNE, if required. It is recommended that the maximum number of AGNEs per alarm group be limited to at most two to assure good performance.
Instead of having every NE exchange alarm/status information with every other NE in the same alarm group directly, only the AGNE receives alarm/status information from every NE directly, and the
AGNE distributes the accumulated alarm/status information for all the
NEs to every NE in the alarm group.
Provisioning sequence
If there is no AGNE, each NE in an alarm group reports an
AGNE
Communications Failure
alarm; therefore, the following provisioning sequence is recommended:
1.
Provision one or two (at most) NEs as the AGNE
• Enable the Remote NE Status parameter
• Enable the network element as an Alarm Gateway
• Provision the alarm group number, if different than the default.
2.
Provision the other NEs in the same alarm group
• Enable the Remote NE Status parameter
• Provision the alarm group number, if different than the default.
For more information about the
Administration>Set NE
command, refer to the WaveStar
®
CIT help.
...........................................................................................................................................................................................................................................................
6 - 1 1 6
365-372-300
Issue 8.0 September 2006
Remote NE Status
Operations, Administration, Maintenance, and Provisioning
Remote NE status compatibility
The following table lists DMX remote NE status compatibility with other products.
Table 6-11 Remote NE Status Compatibility
DMX
Product
DMX
Metropolis
®
DMX
tend
Metropolis
®
DMXpress
Metropolis
®
DMXplore
DDM-2000 OC-3
DDM-2000 OC-12
FiberReach yes yes yes yes yes yes yes
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
6 - 1 1 7
Operations, Administration, Maintenance, and Provisioning
Network Size
............................................................................................................................................................................................................................................................
Overview
There is no inherent limit to the total number of NEs in a SONET transmission network, but there is a limit to the number of nodes that can be part of the same OSI domain, that is, with OSI LAN and/or DCC connectivity for operations communications among the NEs.
Maximum number of OSI nodes
In R6.0, the total number of OSI associations per TCP has been increased from 64 to 300 and the number of OSI associations for TL1 per Gateway Network Element (GNE) has been increased from 200 to
300. These changes make DMX able to support a total of 250 NEs per
Level 1 area.
Prior to R6.0, the maximum number of OSI nodes supported was 50, unless IS-IS Level 2 Routing was used, in which case, up to 256 OSI nodes were supported. Each DMX counts as one OSI node.
IS-IS level 2 routing
IS-IS Level 2 Routing involves the assignment of NEs to multiple areas of less than 50 nodes each. Level 2 routers support OSI communications between the NEs in different areas. Both the assignment of NEs to areas and the enabling of NEs as Level 2 routers is accomplished by provisioning.
...........................................................................................................................................................................................................................................................
6 - 1 1 8
365-372-300
Issue 8.0 September 2006
Operations, Administration, Maintenance, and Provisioning
Directory Services
............................................................................................................................................................................................................................................................
What are directory services?
OS and WaveStar
®
CIT users access remote DMXs using the remote
DMX Target Identifier (TID, name) but remote DMXs are addressed on the DCC using
Network Service Access Point Address (
NSAP). Therefore, a method to provide TID-to-NSAP (name-to-address) and NSAP-to-
TID (address-to-name) translations is necessary. Target Identifier
Address Resolution Protocol (TARP) provides this capability.
For SONET NEs that support TCP/IP and TL1 OS interfaces, TARP is the de facto directory services standard to support multi-vendor OI compatibility. TARP is specified in Telcordia GR-253-CORE, SONET
Transport Systems: Common Criteria.
TID provisioning
Each NE in a network must be provisioned with a unique TID. The
DMX’s default TID is “LT-DMX”. The terms TID and source identifier
(SID) are generally used interchangeably.
Important!
Some other-vendor NEs may require that all TIDs adhere to specific rules, for example, that each TID start with an alphabetic character and/or that each TID consist of at least 6-to-7 characters.
To be compatible with WaveStar products, DMX TIDs should not include special characters “%” and “#”. Even though DMX TID provisioning allows those special characters, T1.245 SONET
Directory Services (SDS) does not support those special characters.
NSAP provisioning
By default, each DMX has a unique Network Service Access Point
(NSAP) address, thus no NSAP provisioning is necessary in small networks. If the network size exceeds 50 OSI nodes, NSAP provisioning is required.
TARP provisioning
Although TARP functions automatically without any user provisioning, using standard default values, DMX allows provisioning of the following TARP parameters. All TARP parameters are provisionable:
• Lifetime
• Manual Adjacency
• Timers
• Loop Detection Buffer (LDB) Flush Timer
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
6 - 1 1 9
Directory Services
Operations, Administration, Maintenance, and Provisioning
TARP TID-to-NSAP translations
• TARP Data Cache (TDC) Enable/Disable
• TDC TID-NSAP Entries.
It is recommended that the TARP default values always be used.
The three operations that depend on TARP TID-to-NSAP translations are:
1.
TL1 OS access
2.
WaveStar
®
CIT access
3.
Remote (Software) Install Program/Copy Program.
When a TL1 TCP/IP
Gateway Network Element (
GNE) receives a TL1 login request for a TL1-RNE, the TL1 login request includes the TL1-
RNE’s TID. The TL1-GNE relies on TARP to determine the TL1-
RNE’s NSAP. The TL1-GNE needs the NSAP to establish an OSI association with the TL1-RNE. The TL1 login request is forwarded to the TL1-RNE over that OSI association.
The local DMX serves as a TL1-GNE and uses TARP as described above for WaveStar
®
CIT access via DMX’s serial ports or TCP/IP.
When accessing DMX via OSI LAN, the WaveStar
®
CIT (or OS) performs the TL1-GNE function and uses TARP in a similar manner, also. The local DMX uses TARP as described above to support remote
Install Program/Copy Program.
TARP propagation
The first time a TL1-GNE (or local DMX) requires a TARP TID-to-
NSAP translation for each remote NE, the TL1-GNE originates a
TARP query. The TARP query is propagated to all NEs in the same OSI routing area, and if no response is received from within the area, up to two additional TARP queries are propagated throughout the OSI domain. Each NE forwards the TARP queries to each of its neighboring
OSI nodes (that is, adjacencies), except the neighbor from which the
TARP query was received.
When the TARP query reaches the remote NE with the requested TID, that remote NE responds to the originating NE with the remote NE’s
NSAP address. If there is no response to any of the TARP queries for a
TID, after the third query times out, an error response (for example,
TL1- GNE unknown TID
or
TID not found
) is returned to the originating NE.
TARP NSAP-to-TID translations
When a DMX is commanded to perform this translation, it knows the
NSAPs of the remote NEs to be included in the responses but relies on
TARP to determine the corresponding TIDs.
...........................................................................................................................................................................................................................................................
6 - 1 2 0
365-372-300
Issue 8.0 September 2006
Directory Services
Operations, Administration, Maintenance, and Provisioning
To ensure that the responses to these commands always include the most up-to-date network information, real-time TARP queries are originated instead of relying on the TARP Data Cache or TDC
(although the TDC is updated, as appropriate, based on the responses to these NSAP-to-TID queries).
Because the NSAPs are known, these TARP queries are addressed directly to each remote NE (TARP propagation is not necessary). Each remote NE responds to the originating NE with the remote NE’s TID.
TARP data cache
In order to reduce the frequency of TARP propagation, and to improve the performance of the affected operations, DMX supports a TDC option. By default, the TDC is enabled.
Each DMX maintains its own TDC, independently. The TDC consists of TID-NSAP translations. Each DMX automatically updates its own
TDC based on the responses to previous TARP queries. The TDC may also be updated upon receipt of an unsolicited, automatic notification from another NE in the same OSI domain of a TID or NSAP change.
DMX checks its TDC to see if it already has a required TID-to-NSAP translation before originating a TARP query. If a translation is not found in the TDC, the response to that TARP query is used to update the originating DMX’s TDC. DMX assures that its TDC maintains only one TID-NSAP translation for each unique TID. DMX supports TDC sizes of up to 110 TID-NSAP translations. If the TDC is disabled or
DMX’s system controller is reset, the contents of the TDC are deleted.
TDC accuracy
In the unlikely event that a TDC includes an inaccurate TID-to-NSAP translation, DMX confirms that both the NSAP and TID of the remote
DMX are correct before a remote operation proceeds. If there is a mismatch, an error response (for example,
TL1-RNE unknown TID
,
Inconsistent TID
, or
Association Setup Failure
) is returned to the originating
NE.
To correct such a situation, delete the subject TID (L4tdctid) from the
TDC, then re-request the remote operation for the subject TID. The subsequent TARP query results in an accurate TID-to-NSAP translation, and the TDC is updated accordingly. A broader solution is to disable and re-enable the TDC in which case all TDC entries are deleted.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
6 - 1 2 1
Operations, Administration, Maintenance, and Provisioning
Security
............................................................................................................................................................................................................................................................
Capabilities
DMX provides security capabilities to protect against unauthorized access to the system.
User types
Five types of users (with tiered restriction levels) are allowed access to the system with a valid user ID and password:
• An Administrator user has access to all the security functional capabilities. Only the privileged and administrator users have access to the security and access functions. These functions include assigning/changing user ID/passwords for other users, setting target identifier (TID) names, resetting the system, and system initialization functions.
• Privileged users can execute all commands
A privileged user has access to all the system functional capabilities. Only the privileged and administrator users have access to the security and access functions. These functions include assigning/changing user ID/passwords for other users, setting target identifier (TID) names, resetting the system, and system initialization functions.
A privileged user can terminate the login session of other individual users (including other privileged users) or terminate all login sessions of non-privileged users.
• General users have access to all the system functional capabilities except security, access, system initialization and software installation functions.
• Maintenance users can only execute commands that access the system, extract reports and execute maintenance functions through a specific set of commands. No privileged commands may be executed by maintenance users.
• Reports-only users can only execute commands that retrieve reports from the system.
Security can be set to a “lockout” state, which blocks non-privileged users from logging in to the system.
System initialization
When the system is first initialized, three privileged default user IDs and passwords are provided. Up to 147 user IDs and passwords can be added, deleted, and/or changed by any of the privileged users. Timeouts are provisionable on a per-user basis.
...........................................................................................................................................................................................................................................................
6 - 1 2 2
365-372-300
Issue 8.0 September 2006
Security
Operations, Administration, Maintenance, and Provisioning
User IDs and passwords
The WaveStar
®
CIT always asks the user for the NE user ID and password with the first NE connection. The user ID and password can be saved for subsequent connections, but the user ID and password can not be saved past the current WaveStar
®
CIT session. User ID and password parameters must be administered on a per-NE basis. You may have a different user ID and/or password on one NE than you have on other NEs.
Each time the number of invalid sequential login attempts reach or exceed the provisionable user ID lockout threshold, the network element reports a Security Alert alarm.
Inactivity timeout period
The inactivity timeout period is the number of minutes after which a user with an inactive session is logged out. A provisionable inactivity timeout period is supported on a per-user basis.
Password aging
The password aging interval is the number of days allowed before a user’s password expires. When a user’s password expires, the user is prompted to select a new password prior to login. The values for the password aging interval are zero (0) or a range from 7 to 999 days. A value of zero (0) disables password aging. The default value is 0.
Password aging does not apply to privileged users’ passwords.
WaveStar
®
CIT default user
IDs and passwords
Two default Privileged user IDs and passwords are initially installed in the WaveStar
®
CIT are LUC01 and LUC02 (LUC-zero-one, and LUCzero-two). Their associated passwords are LUC+01, LUC+02, (LUCplus sign-zero-one, LUC-plus sign-zero-two), respectively.
NE default user IDs and passwords
Three default Privileged user IDs and passwords are initially installed in the NE is LUC01, LUC02, or LUC03 (LUC-zero-one, LUC-zerotwo, and LUC-zero-three). The default password is DMX2.5G.
MAC Address Locking
(R7.0)
DMX allows MAC locking on the LNW70. MAC locking prevents unauthorized users from gaining access to the network through an
Ethernet port, thereby providing a level of security against intrusion attempts. MAC locking restricts access to a bridged Ethernet network by requiring that the source address of traffic entering a locked port be registered with that port. Any number of ports, LANs, VCG, or link aggregation groups (LAGs) can be locked. DMX permits registering of multiple addresses with a single entity.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
6 - 1 2 3
Operations, Administration, Maintenance, and Provisioning
Password Administration (CIT and System)
............................................................................................................................................................................................................................................................
Overview
System administration includes performing the following:
• Changing passwords
• Changing notifications
• Performing security administration
• Viewing NE administration
• Setting TIDs
• Setting NE defaults
• Performing a LAN reset
• Provisioning data communications
• Viewing OSI routing map
WaveStar
®
CIT user ID/ password administration
The
Administration > Security > User Provisioning
command on the
WaveStar
®
CIT View menu allows a privileged user to create, change, or delete another user ID or password.
Important!
Any changes made to a user’s provisioning takes place the next time the user logs in. If the user is currently logged in, no changes take place until that user logs off and logs back in.
Valid WaveStar
®
CIT user IDs
A valid WaveStar
®
CIT user ID must be a minimum of one character to a maximum of ten characters (no character restrictions).
Valid WaveStar
®
CIT passwords
A valid WaveStar
®
CIT password must comply with the following:
• Length must be a minimum of six characters to a maximum of ten characters
• Must begin with a letter
• Must contain at least three non-alphabetic characters (symbol or number)
• At least one of the non-alphabetic characters must be a symbol
• When changing a password, the new password must be different from the previous password by at least three characters and cannot be one of the last 5 passwords used.
...........................................................................................................................................................................................................................................................
6 - 1 2 4
365-372-300
Issue 8.0 September 2006
Administration
Operations, Administration, Maintenance, and Provisioning
Important!
User passwords are case-sensitive.
Characters NOT allowed in a WaveStar
®
CIT password
The following table lists the characters that are not allowed in a
WaveStar
®
CIT password.
Table 6-12 Characters NOT Allowed in a WaveStar
®
CIT
Password
Character
:
,
@
=
Description Character
Space “
Commercial at &
Comma
Colon
;
_
Equals sign ?
Description
Quotation mark
Ampersand
Semicolon horizontal bar
(underscore)
Question mark
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
6 - 1 2 5
Administration
Operations, Administration, Maintenance, and Provisioning
/
.
)
(
!
+
-
'
Characters allowed in a WaveStar
®
CIT password
The following table lists the characters that are allowed in a WaveStar
®
CIT password.
Table 6-13 Characters Allowed in a WaveStar
®
CIT Password
Character
A... Z a... z
0... 9
%
Description Character
Uppercase letters *
Lowercase letters [
Digits ]
Apostrophe
Hyphen
Left parenthesis {
Right parenthesis }
`
^
Period (full stop) |
Slash (Solidus) <
Plus sign
Exclamation mark
>
~
Percent sign #
Description
Asterisk
Left square bracket
Right square bracket
Caret
Grave accent
Left curly brace
Right curly brace
Vertical bar
Less than
Greater than
Tilde
Number sign
...........................................................................................................................................................................................................................................................
6 - 1 2 6
365-372-300
Issue 8.0 September 2006
Administration
Operations, Administration, Maintenance, and Provisioning
DMX user ID/password administration
Changing your own WaveStar
®
CIT password
The WaveStar
®
CIT
Administration > Change Password
command allows any user to change his or her own WaveStar
®
CIT password.
Only privileged users can change another user’s ID or password.
The Change Password screen is also automatically invoked immediately after the login screen if a user’s password has expired. The user is prevented from performing any other function until the password is successfully changed. This screen is also invoked the first time a login is attempted for a new user ID.
The
Administration > Security > User Provisioning
command on the network element System View menu allows a privileged user to create, change, or delete another network element user ID or password.
Important!
Any changes made to a user’s provisioning takes place the next time the user logs in. If the user is currently logged in, no changes take place until that user logs off and logs back in.
Valid DMX user IDs
A valid user ID must be a minimum of five allowed characters to a maximum of ten allowed characters.
Valid DMX passwords
A valid password must comply with the following conditions:
• Length must be a minimum of six characters to a maximum of ten characters
• Must contain at least one alphabetic character and at least three non-alphabetic characters (symbol or number)
• At least one of the non-alphabetic characters must be number and at least one must be a symbol
• When changing a password, the new password must be different from the previous password by at least one character.
Important!
User passwords are case-sensitive.
Characters NOT allowed in a DMX password and user ID
The following table lists the characters that are not allowed in a password and user ID.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
6 - 1 2 7
Administration
Operations, Administration, Maintenance, and Provisioning
Table 6-14 Characters NOT Allowed in a DMX Password and
User ID
Character
:
,
\
@
=
Description
Comma
Colon
Character
Space
Commercial at ;
“
*
!
Equals sign
Back slash
?
Description
Quotation mark
Semicolon
Asterisk
Exclamation
Mark
Question mark
Characters allowed in a DMX password and user ID
The following table lists the characters that are allowed in a password and user ID.
Table 6-15 Characters Allowed in a DMX Password and User ID
]
/
.
)
(
[
+
Character
A... Z
-
' a... z
0... 9
Description Character
Uppercase letters ^
Lowercase letters `
Digits {
Apostrophe
Hyphen |
}
Left parenthesis <
Right parenthesis >
Period (full stop) ~
Slash (Solidus) %
Plus sign
Left square bracket
Right square bracket
#
&
_
Description
Caret
Grave accent
Left curly brace
Right curly brace
Vertical bar
Less than
Greater than
Tilde
Percent sign
Number sign
Ampersand
Horizontal bar
(underscore)
...........................................................................................................................................................................................................................................................
6 - 1 2 8
365-372-300
Issue 8.0 September 2006
Administration
Operations, Administration, Maintenance, and Provisioning
Changing your own password
From the network element System View, the
Administration > Change
Password
command allows any user to change his or her own password. Only privileged users can change another user’s ID or password.
When a user changes their own password, the new password must be different in at least three character positions from the current password.
The original password, or a significant substring of it, must not be part of the new password.
• If the current and new passwords are the same length, then the characters in at least 3 character positions must be different.
• If the current and new passwords are different lengths, then for every possible contiguous substring of the length of the shorter password within the longer password, the characters in at least three character positions must be different between the shorter password and the character substring within the longer password.
Also, the password cannot be one of the last 5 used.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
6 - 1 2 9
Operations, Administration, Maintenance, and Provisioning
User-setable Miscellaneous Discrete Interface
............................................................................................................................................................................................................................................................
Overview
This section describes the miscellaneous discrete environmental alarm/ status input points and (external) control output points.
Description
The user-setable miscellaneous discrete interface allows users to monitor and control equipment collocated with DMX through a set of discrete input and output points. There are 19 miscellaneous discrete inputs to monitor environmental conditions such as open doors or high temperature, and 4 miscellaneous discrete outputs to control equipment such as fans and generators.
Local miscellaneous discrete input points are included in the determination of the summary alarm/status level for each NE. But even if the Remote NE Status feature is enabled, the alarm/status of
individual miscellaneous discrete inputs/outputs is not exchanged among NEs.
Miscellaneous discrete input alarm level
The alarm level to be associated with each miscellaneous discrete input point is provisionable. By default, each miscellaneous discrete input is a minor alarm.
If a miscellaneous discrete input point is provisioned as an alarm
(minor, major, or critical), TL1 autonomous message REPT ALARM
EVT is used to report the alarm occurrence. This identifies the remote
NE to further query.
If a miscellaneous discrete input point is provisioned as not alarmed
(that is, status), TL1 autonomous message REPT EVT CON is used to report the condition. This identifies the need to retrieve any active miscellaneous discrete status conditions.
Miscellaneous discrete input description
The description to be associated with each miscellaneous discrete input alarm or status point may be provisioned. The provisioned description appears as the
almmsg
or
conddescr
parameter value in applicable TL1 messages. The default description for each miscellaneous discrete input point is
environment1
,
environment2
, and so forth.
Note that miscellaneous discrete Input Point 15 is reserved for fan failure.
Miscellaneous discrete output description
The description to be associated with each miscellaneous discrete output control point may be provisioned. The default description for each miscellaneous discrete output point is
control1
,
control2
, and so
...........................................................................................................................................................................................................................................................
6 - 1 3 0
365-372-300
Issue 8.0 September 2006
User-Setable Miscellaneous Discrete Interface
Operations, Administration, Maintenance, and Provisioning
forth. Control points for miscellaneous discrete outputs may be operated and then released.
Fan Failure
Miscellaneous Discrete #15 is reserved for fan failure. The possible alarm levels are CR, MJ, MN, with MJ being the default.
Reference
For information about the
Configuration>Misc. Discretes
command, refer to the WaveStar
®
CIT help. For detailed wiring information, refer to the
Metropolis
®
DMX Access Multiplexer Installation Manual,
365-372-
304
.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
6 - 1 3 1
User-Setable Miscellaneous Discrete Interface
Operations, Administration, Maintenance, and Provisioning
...........................................................................................................................................................................................................................................................
6 - 1 3 2
365-372-300
Issue 8.0 September 2006
7 Ordering
Overview
............................................................................................................................................................................................................................................................
Purpose
This chapter contains information on ordering Metropolis DMX
Access Multiplexer equipment and software. The information in this chapter tells you where to go for ordering information.
Contents
Ordering topics included in this chapter are:
Miscellaneous Equipment and Tools
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
7 - 1
Ordering
Introduction
............................................................................................................................................................................................................................................................
Overview
Lucent has created a set of engineering drawings to facilitate the ordering of all products in the future. These drawings are updated for each planned Release, and contain all of the information needed to order DMX equipment. The information contained in the engineering drawings will not be duplicated anywhere in the interest of keeping all information current and consistent at all times. This chapter will explain how to make sure you are using the most current version of the engineering drawing and where to order it.
Software and Documentation ordering information is not included in the engineering drawings and is therefore included in this chapter. Any information about particular pieces of equipment (i.e. the uses of various cables versus other) is meant to convey useful information that may/may not be contained in the engineering drawings. This information is meant to be used in conjunction with engineering drawings, but not to replace them.
How to order
Equipment and software orders may be placed via Lucent’s online ordering process. For more information, contact your Account
Executive.
...........................................................................................................................................................................................................................................................
7 - 2
365-372-300
Issue 8.0, September 2006
Ordering
Engineering Drawings
............................................................................................................................................................................................................................................................
Overview
In the interest of ensuring that ordering information is always consistent and up-to-date, Lucent has created a set of engineering drawing meant to contain all information needed to order a DMX system.
Where to Obtain
Engineering Drawings
The engineering drawing is likely to be updated more frequently than the Applications and Planning Guide. Order the most current version of the engineering drawing from CIC.
Whenever ordering equipment, first be sure that you have the most current version of ED8C871-10. You may do so by contacting CIC through one of the mediums detailed below.
How to order Engineering
Drawings
The most up-to-date version of the Engineering drawing
(ED8C871-10) may be obtained through CIC. There are 2 ways to obtain material from CIC.
If you are a Lucent employee and are on the Lucent internal web:
• Go to www.lucentdocs.com and follow the link for Drawings.
Enter the drawing number in the proper field (ED8C871-10).
• Verify that the drawing you have is the same Issue number as the drawing on the site.
• If it is not the same issue, follow the steps on the CIC website for ordering a new drawing.
• If it is the same issue, the drawing is sufficient to help you configure an order.
• Contact CIC by phone: 1-888-582-3688
If you are a non-Lucent employee/outside customer
• Contact CIC by phone: 1-888-582-3688 OR
• Go to http://www.lucent8.com/cgi-bin/CIC_store.cgi?
• Click on Drawings in the menu at the left of the screen.
• Enter the drawing number (ED8C871-10) in the field provided.
• Click on Search.
• Click on the drawing number.
• Choose the media by which you wish to receive the drawing and purchase the drawing.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
7 - 3
Ordering
Software and Documentation
............................................................................................................................................................................................................................................................
Overview
This section provides software ordering information.
Software releases included in this section are:
• Release 7.0 Software
Software ordering information
Listed below are some need-to-know items before ordering DMX software:
• DMX software is shipped separately from the hardware.
• Order one set of software for each shelf ordered. Software orders must be placed in addition to the hardware order to receive software.
• All system controller (SYSCTL) circuit packs are shipped without software loaded on them. Therefore, software loading must occur at or before installation.
• It may be desirable to have backup CD-ROMs for all releases on hand for backup or initial downloading.
• The software ordering table includes a cross-reference to comcodes where available.
• DMX software includes PC/CIT software.
• Initial Release software includes a CD containing the current documentation to accompany the DMX. Hardcopies of the most current documentation are available through CIC.
...........................................................................................................................................................................................................................................................
7 - 4
365-372-300
Issue 8.0, September 2006
Ordering
Available software
The table below lists the DMX software that may currently be ordered.
Table 7-1 Orderable Software
Comcode Product Release Description
109629477 R7.0
109629485 R7.0
109629386 R7.0
(CD-ROM and SRD)
(CD-ROM and SRD)
(CD-ROM and SRD)
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
7 - 5
Ordering
Available documentation
The table below lists documentation that may currently be ordered.
Documents that come with a shelf assembly order or a software order are noted.
Table 7-2 Orderable Documentation
Document
Number
365-372-300
Title
365-372-301
365-372-302
365-372-304
365-372-306
109596528
(comcode)
DMX Access Multiplexer Applications and
Planning Guide
(Note 1)
DMX Access Multiplexer User Operations
Guide
(Note 1)
DMX Access Multiplexer Alarm Messages and
Trouble Clearing Guide
(Note 1)
DMX Access Multiplexer Installation Manual
(Note 1)
DMX Access Multiplexer TL1 Message Details
DMX User Documentation CD, Release 6
(Note 2)
Important!
The comcodes for these documents are not supplied so as to limit confusion. This book, the Applications and Planning
Guide, is not updated concurrently with the other documents listed in this table, but before them. As such, if comcodes were supplied here, it could result in confusion and the ordering of the wrong version of a document. Use the telephone number for CIC, provided on page 3 of this Chapter, to obtain the correct comcodes for the desired documents. The comcode for the User
Documentation CD is supplied, but it is recommended that CIC be called to verify that the correct version of the CD is being ordered.
Table notes
1.The DMX Access Multiplexer User Operations Guide, Alarm
Messages and Trouble Clearing Guide, Installation Manual,
Aplications and Planning Guide, and TL1 Message Details (in CD-
ROM form) are shipped with the software. The documents may be ordered separately as well.
2.The DMX Access Multiplexer Software Release Description and User
Documentation CD-ROM are shipped with a software order. The CD-
ROM may be ordered separately.
...........................................................................................................................................................................................................................................................
7 - 6
365-372-300
Issue 8.0, September 2006
Ordering
Miscellaneous Equipment and Tools
............................................................................................................................................................................................................................................................
Lightguide build-outs
DMX utilizes Lucent’s state-of-the-art AllWave ADVANTAGE
TM
Fiber
Optic Attenuators. These attenuators reduce optical power from the transmitter that can result in over-saturation of the receiver, have low reflection to meet stringent system requirements, and are backwardcompatible with existing transmission systems. Unique to the AllWave
ADVANTAGE optical connectivity solution (OCS), the new LC
TM optic attenuators are designed to provide flat spectral loss across the full spectrum, allowing the attenuators to be used in the 1300 nm, 1400 nm, and 1500 nm bands. LC optical attenuators are ideal for networks deploying AllWave fiber, metropolitan or regional networks, applications supported by conventional single-mode optical fiber, multiservice network protocols, and DWDM networks.
The table below lists the available LC-type lightguide build-out attenuators for the DMX.
Table 7-3 Lightguide Build-outs and Accessories
Description
LC Build-Out Attenuators
5 dB
10 dB
15 dB
20 dB
Allwave ADVANTAGE
TM
Fiber Optic
Identification Kit
108279381
108279431
108279480
108279530
108622929
1
2
Table notes
1.The LC build-out attenuators listed are connector style PC (polished connectors) at the fiber end. These attenuators must be used on the receive side in all cases. For the LNW36 and LNW39 OC-3 and
LNW46 and LNW49 OC-12 circuit packs, the specified attenuation may not be achieved if a SM-MM (single-mode-multi-mode) fiber signal is incoming to the LC SM-SM attenuator. In this case, a 15 dB attenuator, for example, may achieve an attenuation value less than the specified 15 dB.
2.The AllWave ADVANTAGE Fiber Optic Identification Kit includes labels for fiber optic apparatus products to identify Lucent AllWave
Fiber paths. An instruction sheet is included with recommendations on how to install and use the labels.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
7 - 7
Ordering
Pluggable Transmission
Modules
DMX utilizes Pluggable Transmission Modules (PTMs), also known as
SFPs, on the LNW37, LNW45, LNW49, LNW59, LNW62, LNW63,
LNW64, LNW70, LNW73/73C, LNW74, and LNW78 packs. To ensure proper optical performance, mechanical fit, compliance with
EMC, and compliance with laser safety standards, the Lucent specified
PTM transceivers listed in the table below must be used.
Only the Lucent specified PTM transceivers listed below are compatible with DMX software. If non-Lucent specified PTM transceivers are installed in DMX, the system will reject that transceiver, and that optical port will become inoperable (until approved parts are installed).
Laser Safety CAUTION!
Use only the Lucent specified Class 1 transceivers listed in the table below.
The table below lists the PTM optics that may be used in the LNW37,
LNW45, LNW49, LNW59, LNW62, LNW63, LNW64, LNW70,
LNW73/73C, LNW74, and LNW78 circuit packs.
...........................................................................................................................................................................................................................................................
7 - 8
365-372-300
Issue 8.0, September 2006
Ordering
SONET
Optical
PTMs
Apparatus Code
S15512
OC3IR1-I1
OC3LR1-I1
OC12IR1-I1
OC12LR1-I1
OC12LR2-I1
OC48LR1-I1
OC48LR2-I1
OC192SR1-C1
OC192IR2-C1
OC192LR2-C1
Table 7-4 PTM Optics for LNW37/45/49/59/62/63/64/70/73/73C/
74/78
Comcode
109602599
109453894
109453886
109453902
109467522
109604447
109493528
109504431
109537902
109537563
109537555
Description
OC3 PTM TRCVR
Short Reach, 1.3 SR-1, 1310nm
OC3 PTM TRCVR
Intermediate Reach, 1.3 IR-1,
1310nm
OC3 PTM TRCVR
Long Reach, 1.3 LR-1, 1310nm
OC12 PTM TRCVR Intermediate
Reach, 1.3 IR-1, 1310nm
OC12 PTM TRCVR
Long Reach, 1.3 LR-1, 1310nm
OC12 PTM TRCVR
Long Reach, 1.5 LR-2 (80km),
1510nm
OC48 PTM TRCVR
Long Reach, 1.3 LR-1 (40km),
1310nm
OC48 PTM TRCVR
Long Reach, 1.5 LR-2 (80km),
1550nm
OC192 XFP TRCVR
Short Reach, 1.3 SR-1 (2km),
1310nm
OC192 XFP TRCVR
Intermediate Reach, 1.5 IR-2
(40km), 1310nm
OC192 XFP TRCVR
Long Reach, 1.5 LR-2 (80km),
1550nm
Used In
LNW37/45
LNW37/45
LNW37/45
LNW49
LNW49
LNW49
LNW62
LNW62
LNW59
LNW59
LNW59
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
7 - 9
Ordering
Apparatus Code
100BASE-LX-I1
(FE-TX)
GE-1X2XFC-SX-C1
(1000BASE-SX,
1Gbps and 2 Gbps
Fibre-Channel)
GE-1X2XFC-LX-C1
(1000BASE-LX,
1Gbps and 2 Gbps
Fibre-Channel/
FICON)
GE-1X2XFC-SX-I1
(1000BASE-SX,
1Gbps)
Ethernet and SAN
PTMs
(optical and electrical)
GE-1X2XFC-LX-I1
(1000BASE-LX,
1Gbps)
1000BASE-ZX-I1
(1000BASE-ZX,
1Gbps)
BASE-T-C1
FE and GbE
(electrical- NOT OSP)
ESCON-MM-I1
(ESCON)
Comcode Description
109527812 Optical Fast Ethernet PTM,
LC-type connectors (FE-1310SM)
109527796
109527804
109570606
109568782
GbE short-reach, Single-Mode
PTM, supports Ethernet and Fibre-
Channel traffic, LC-type connectors
(GbE/FC/2FC-850)
GbE long-reach, Single-Mode PTM, supports Ethernet, FICON, and
Fibre-Channel traffic, LC-type connectors
(GbE/FC/2FC-1310)
GbE short-reach, Single-Mode
PTM, supports Ethernet and Fibre-
Channel traffic, LC-type connectors, OSP hardened
(GbE/FC/2FC-850)
GbE long-reach, Single-Mode PTM, supports Ethernet, FICON, and
Fibre-Channel traffic, LC-type connectors, OSP hardened
(GbE/FC/2FC-1310)
109541862
109565549
GbE Short-reach, Single-Mode
PTM, supports Ethernet, LC-type connectors, and is OSP hardened
(GbE-1550)
Electrical PTM, provisionable to
100 or 1000 Mbps, Lucent
Approved
RJ-45 Cat 5-E cable, maximum span length of 100 meters
109523886 ESCON, Multi-Mode PTM,
LC-type connectors (ESCON-1310)
Used In
LNW74/70/78
LNW70/73/
73C/78
LNW70/73/
73C/78
LNW63/64/70/
73/73C
LNW63/64/70/
73/73C
LNW63/64/70/
73/73C/78
LNW63/64/70
LNW73/73C
...........................................................................................................................................................................................................................................................
7 - 1 0
365-372-300
Issue 8.0, September 2006
Ordering
Accessories
The table below shows the miscellaneous accessories available for
DMX.
Table 7-5 Miscellaneous Accessories
Product Model/Description Comcode ITE#
ITE-7129
Installation
Order #
33712900 Optical Fiber
Scope
2.5mm Universal
Adapter Cap
1.25mm Universal
Adapter Cap
Video Fiber Scope
1
Individual, presaturated alcohol wipes
CLETOP Cleaning
Cassette
CLETOP Cleaning
Cassette
Replacement Reel
Luminex Stick port cleaners
Luminex Stick port cleaners
Luminex Stick port cleaners
Noyes OFS 300-200X 408197028
For use with the Noyes
OFS 300-200X
For use with the Noyes
OFS 300-200X
Noyes VFS-1
99% pure isopropyl alcohol
Type A Reel
Type A Reel
1.25 mm
2.5 mm
5.5” x 5.5”
408197044
408197069
TBD
901375147
901375154
901375014
901375030
901375022
408201226
ITE-7129D1 33712901
ITE-7129D2 33712902
TBD
ITE-7136
ITE-7137
TBD
33713600
ITE-7137 D1 33713701
ITE-7134
ITE-7135
R6033
33713700
33713400
33713500
23603300
Table notes
1.This equipment may not be necessary at all locations. It is to be used when the ports need to be verified for cleanliness. If care is exercised when cleaning fibers, the video scope may not be needed.
2.The equipment and material listed above has been tested and is proven effective. Substitution of equipment or materials is at the discretion of the user and is not recommended.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
7 - 1 1
Ordering
...........................................................................................................................................................................................................................................................
7 - 1 2
365-372-300
Issue 8.0, September 2006
8 Product Support
Overview
............................................................................................................................................................................................................................................................
Purpose
This chapter describes the support services available to Lucent
Technologies’ customers.
Lucent Technologies offers a number of services to assist customers with Engineering, Installation and Technical Support of their networks.
Additionally, Lucent Technologies offers product-specific training courses.
Contents
The following topics are discussed in this chapter:
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
8 - 1
Product Support
Worldwide Services
............................................................................................................................................................................................................................................................
Overview
Lucent Worldwide Services provides a full life-cycle of services and solutions to help you plan, design, implement, and operate your network in today's rapidly changing and complex environment.
Engineering Services
Engineering Services provide information and technical support to customers during the planning, implementation, and placement of equipment into new or existing networks. We determine the best, most economical equipment solution for a customer and help ensure equipment is configured correctly for the customer’s network needs, works as specified, and is ready for installation on delivery. These services consist of the following:
• Equipment engineering
• Software engineering
• Site records
• Engineering consulting
• Additional engineering services (Network Realignment, System
Capacity Planning, System Health Assessment)
Installation Services
Lucent Technologies offers Installation Services focused on providing the technical support and resources customers need to efficiently and cost-effectively install their network equipment. We offer a variety of options that provide extensive support and deliver superior execution to help ensure the system hardware is installed, tested, and functioning as engineered and specified. Installation Services provides a complete flexible solution tailored to meet customers' specific needs. These services consist of the following:
• Equipment installation
• Specialized equipment installation
• Network connectivity services
• Installation support services
...........................................................................................................................................................................................................................................................
8 - 2
365-372-300
Issue 8.0 September 2006
Worldwide Services
Product Support
Technical Support
Web-Site
For technical support, contact your local customer support team. You can reach them via the Web at the Lucent Customer Support Web Site
(http://support.lucent.com) or the customer support telephone number listed at the Lucent Contact Us Web Site
(http://www.lucent.com/contact/).
For additional information regarding Worldwide Services, refer to the
Lucent Technologies’ web-site at
http://www.lucent.com/products
1.
Click on
Browse the catalog
2.
Click on
Worldwide Services Solutions
3.
Select the desired service to display:
• Engineering and Installation
• Technical Support Services
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
8 - 3
Product Support
Training
............................................................................................................................................................................................................................................................
Overview
Lucent Technologies offers a formal training curriculum to complement your product needs.
Registering for a course
To review the available courses or to enroll in a training course at one of Lucent’s corporate training centers,
• Within the United States,
– Visit
https://www.lucent-product-training.com
– Call
1-888-LUCENT8
(888-582-3688): Prompt 2.
• Outside the continental United States,
– Visit
https://www.lucent-product-training.com
– Contact your in-country training representative
– Call:
+1-407-767-2798
– Fax:
+1-407-767-2677
Suitcasing
To arrange for a suitcase session at your facility,
• Within the United States, call
1-888-LUCENT8
(888-582-3688):
Prompt 2.
• Outside the continental United States,
– Contact your in-country training representative
– Call:
+1-407-767-2798
– Fax:
+1-407-767-2677
...........................................................................................................................................................................................................................................................
8 - 4
365-372-300
Issue 8.0 September 2006
9 Reliability and Quality
Overview
............................................................................................................................................................................................................................................................
Contents
The following reliability and quality information is included in this chapter:
Reliability Program and Specifications
International Standards Organization (ISO) Certification
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
9 - 1
Reliability and Quality
Lucent’s Quality Policy
............................................................................................................................................................................................................................................................
Quality Policy
Quality plan
We will safeguard the customers' trust by building the capability to execute flawlessly on the promises we make.
This Lucent Technologies Quality Policy guided the development of the DMX Access Multiplexer and will continue affecting this product throughout its life cycle. The primary tool ensuring product quality is the Quality Plan.
...........................................................................................................................................................................................................................................................
9 - 2
365-372-300
Issue 8.0, September 2006
Reliability and Quality
Reliability Program and Specifications
............................................................................................................................................................................................................................................................
Overview
The reliability program provides enhanced reliability and is implemented as an integral part of the Lucent Technologies’ Process
Management Architecture (PMA) process. The reliability program is comprehensive, and includes activities such as setting and ensuring compliance with customer-focused system-reliability requirements, ensuring component qualification is consistent with use environment and system design, assuring satisfactory component-attachment reliability, predicting failure rates of Field Replaceable Units (FRUs), making sparing recommendations, assessing reliability architecture, modeling system reliability, assuring satisfactory system-downtime performance, reducing hardware failure rates through Environmental
Stress Testing (EST), and tracking field returns.
Design and development
During the design and development stage, reliability predictions, qualification and selection of components, definition of quality assurance audit standards, and prototyping of critical areas of the system ensure built-in reliability.
Manufacturing and field deployment
During manufacturing and field deployment, techniques such as environmental stress testing, production quality audits, field-return tracking, failure-mode analysis, and feedback and corrective-action further enhance the ongoing reliability improvement efforts on the
DMX Access Multiplexer.
Environmental Stress
Testing
DMX circuit packs are subjected to an Environmental Stress Testing
(EST) program. The purpose of the program is to improve reliability by reducing early life failures and implementing root-cause analysis and corrective action on circuit packs that fail EST.
Transmission downtime
DMX satisfies a stringent set of reliability specifications. Some of the critical specifications include Telcordia Technologies downtime requirements and objectives for multiplexers. Telcordia Technologies requirements state that the downtime of a two-way channel within a
SONET multiplexer, due to hardware failure, shall be less than 1.75 minutes per year in a Central Office (CO) environment and 5.25 minutes per year in a Remote Terminal (RT) environment. The corresponding objectives for these parameters are 0.25 minutes per year in a CO environment and 0.75 minutes per year in an RT
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
9 - 3
Reliability Program and Specifications
Reliability and Quality
environment. These requirements and objectives appear in Telcordia
Technologies GR-418-CORE.
These requirements and objectives apply to all system elements needed to process a two-way channel, including the core system as well as the high-speed and low-speed interfaces. System-reliability analysis employing Markov modeling is used to determine the system downtimes. As specified in Telcordia Technologies GR-418-CORE, this analysis assumes a mean time to repair of 2 hours for the CO environment and 4 hours for the RT environment. Individual Field
Replacable Unit (FRU) failure rates used in the model were determined using the method described in Telcordia Technologies SR-332,
“Reliability Prediction Procedure for Electronic Equipment (RPP).”
FRUs are system elements that can be replaced in the field, including items such as circuit packs, removable optical interfaces, housings, cooling units, and removable LEDs.
...........................................................................................................................................................................................................................................................
9 - 4
365-372-300
Issue 8.0, September 2006
Reliability and Quality
Failure Rates
............................................................................................................................................................................................................................................................
Overview
This section provides circuit pack and equipment failure rates for
DMX.
Circuit Pack Failure rates
The table below provides failure-rate predictions for all circuit packs available through R7.0. These failure rates were determined per
Telcordia SR-332. System-inlet air of 25oC is assumed in the predictions for the CO environment. Failure-rate predictions are estimates; actual values may vary.
Circuit Pack Apparatus Code Slot(s) Release
Failure Rate in CO
(FIT)
Failure Rate in
RT
(FIT)
System Controller
(SYSCTL)
System Controller
(SYSCTL)
LNW1
LNW2
Non-volatile Memory
Card
NVM
Headless MAIN Switch pack
LNW80
OC-192 OLIU
OC-192 OLIU
OC-192 OLIU
OC-192 PTM OLIU
OC-192 OLIU
OC-192 OLIU
OC-192 OLIU
OC-192 OLIU
LNW56
LNW57
LNW58
LNW59
LNW60
LNW523
LNW527
LNW554
CTL
CTL
LNW2
M1, M2
M1, M2
M1, M2
M1, M2
M1, M2
M1, M2
M1, M2
M1, M2
M1, M2
1.0
6.0
6.0
4.0
5.1
4.0
4.0
4.0
2.1
4.0
2.1
7.0
4565
7747
197
6108
8527
9227
7902
TBS
9188
9119
9119
9119
9131
15494
394
12216
NA
NA
NA
NA
NA
NA
NA
NA
OC-192 OLIU
OC-48 OLIU
OC-48 OLIU
OC-48 OLIU
LNW555
LNW29
LNW28
LNW26
M1, M2
M1, M2
M1, M2
M1, M2
3.1
2.1
2.0
1.0
8640
8259
6921
8452
NA
NA
13842
NA
OC-48 OLIU
OC-48 OLIU
LNW26B
LNW27
M1, M2
M1, M2
2.0
2.1
6921
8090
NA
NA
OC-48 OLIU LNW31 A-D, G1, G2 2.0
5404 NA
OC-48 OLIU LNW32 A-D, G1, G2 4.0
8167 16335
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
9 - 5
Failure Rates
Reliability and Quality
Circuit Pack
OC-48 PTM OLIU
OC-48 OLIU
OC-48 OLIU
OC-48 OLIU
OC-48 OLIU
OC-48 OLIU
OC-12 OLIU
OC-12 OLIU
OC-12 OLIU
OC-12 OLIU
OC-12 OLIU
OC-3 OLIU
28DS1PM
56DS1/E1
10/100T (100BASE-TX)
Private Line
1000BASE-SX
1000BASE-.LX
1000BASE-X
GbE Private Line (4 ports)
1000BASE-X
GbE Private Line (8 ports)
Apparatus Code
LNW62
LNW76
Slot(s)
A-D, G1, G2
M1, M2
LNW77
LNW121B-
159B
M1, M2
M1, M2
LNW221-259
LNW421-459
LNW46
LNW48
LNW54
LNW49
LNW50
LNW36
LNW7
LNW8
10/100T (100BASE-TX) LNW66
LNW71
LNW67
LNW68
LNW63
LNW64
M1, M2
A-D, G1, G2
A-D, G1, G2
M1, M2
M1, M2
A-D, G1, G2
M1, M2
A-D, G1, G2
OC-3 PTM OLIU
OC-3 OLIU
12DS3/EC1
48DS3/EC1
LNW37 (pack) A-D, G1, G2
LNW45 A-D, G1, G2
LNW16
LNW19
A-D
A-D
48DS3/EC1 LNW19B
12DS1/DS3 TransMUX LNW18
48DS3EC1TMUX
28DS1
LNW20
LNW6
A-D
A-D
A-G
A-D
A-D
A-D
1.0
3.1
A1, B1, C1, D1 1.1
A1, B1, C1, D1 3.1
A-G
A-G
A-G
A-G
7.0
2.1
2.0
2.0
5.1
4.0
3.1
1.1
2.1
3.0
1.1
3.1
5.0
3.0
7.0
1.0
4.0
5.0
1.0
3.1
1.1
1.1
6.0
7.0
Release
TBS
Failure Rate in CO
(FIT)
TBS
7042
Failure Rate in
TBS
NA
RT
(FIT)
5625
7215
NA
NA
8375
4847
3111
5091
4628
4523
5236
4076
5047
5226
10094
10452
4520 9040
5595 11190
5909
4294
11818
8587
TBS TBS
5575 11150
NA
NA
6222
10182
9256
9046
10472
8152
5575 11150
5309 10618
5102
6391
NA
NA
7264
7808
6884
NA
NA
13768
TBS
...........................................................................................................................................................................................................................................................
9 - 6
365-372-300
Issue 8.0, September 2006
Failure Rates
Reliability and Quality
Circuit Pack
1000BASE-X/
100BASE-FX
FC-DATA (FICON/
ESCON/FC)
FC-DATA (FICON/
ESCON/FC) w/
Compression
Apparatus Code
LNW70
LNW73
LNW73C
100BASE-LX/
10/100BASE-TX
Private Line
RPR 1000BASE-X/
100BASE-TX
Private Line
LNW74
LNW78
Electric Continuity Test
Tool
LNW94
A-G
A-G
A-G
A-G
A-G
A-D
Slot(s)
5.1
Release
5.1
7.0
5.0
6.0
3.1
Failure Rate in CO
(FIT)
9459
Failure Rate in
NA
RT
(FIT)
6445
TBD
7191
9459
NA
NA
NA
14383
NA
NA
NOTE: These Circuit Pack Failure Rates are subject to change.
PTM (SFP/XFP) Failure rates
The table below provides failure-rate predictions for all Pluggable
Transmission Modules (PTMs, also known as SFPs and/or XFPs) available through R7.0. These failure rates were determined per
Telcordia SR-332. System-inlet air of 25oC is assumed in the predictions for the CO environment. Failure-rate predictions are estimates; actual values may vary.
Circuit Pack
OC-12 OLIU
OC-3 PTM OLIU
Apparatus Code
LNW49
Slot(s)
A-D, G1, G2
LNW49 (IR PTM) LNW49
LNW49 (LR-1
PTM)
LNW49
LNW49 (LR-2
PTM)
LNW49
LNW37 (pack) A-D, G1, G2
LNW37 (IR PTM) LNW37
LNW37 (LRPTM) LNW37
7.0
4.0
4.0
4.0
4.0
4.0
4.0
Release
Failure Rate in CO
(FIT)
4523
409
409
Failure Rate in
9046
818
818
RT
(FIT)
TBS NA
5047
407
464
10094
814
928
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
9 - 7
Failure Rates
Reliability and Quality
Circuit Pack
OC-48 PTM OLIU
OC-192 PTM OLIU
Apparatus Code
LNW62
OC48LR1-I1
OC48LR2-I1
LNW59
X10GMC2
X10GMC4
X10GMC5
GbE short-reach, Multi-
Mode PTM, supports
Ethernet and Fibre-
Channel traffic, LC-type connectors
(GbE/FC/2FC-850)
GE-1X2XFC-SX-
C1
GbE long-reach,
Single-Mode PTM, supports Ethernet,
FICON, and Fibre-
Channel traffic, LC-type connectors
(GbE/FC/2FC-1310)
GE-1X2XFC-LX-
C1
GbE short-reach, Multi-
Mode PTM, supports
Ethernet and Fibre-
Channel traffic, LC-type connectors, OSP
Hardened
(GbE/FC/2FC-850)
GE-1X2XFC-SX-
I1
GbE long-reach,
Single-Mode PTM, supports Ethernet,
FICON, and Fibre-
Channel traffic, LC-type connectors, OSP
Hardened
(GbE/FC/2FC-1310)
GE-1X2XFC-LX-
I1
Provisionable to 100 or
1000Mbps, supports
Ethernet
(FE and GbE, electrical)
BASE-T-C1
Slot(s)
A-D, G1, G2
LNW62
LNW62
M1, M2
LNW59
LNW59
7.0
7.0
LNW59 7.0
LNW70/73/73c/78 5.1
7.0
7.0
7.0
7.0
Release
LNW70/73/73c/78 5.1
LNW63/64/70/73/
73C
6.0
LNW63/64/70/73/
73c
6.0
LNW63/64/70 6.0
Failure Rate in CO
(FIT)
TBS
TBS
Failure Rate in
TBS
TBS
RT
(FIT)
TBS
TBS
TBS
TBS
TBS
105
TBS
NA
NA
NA
NA
NA
310
190
310
244
NA
380
620
NA
...........................................................................................................................................................................................................................................................
9 - 8
365-372-300
Issue 8.0, September 2006
Failure Rates
Reliability and Quality
Circuit Pack
Optical PTM, 100
Mbps, LC-type connectors, OSP hardened
(FE-TX)
Optical PTM, 100
Mbps, LC-type connectors, OSP hardened
(FE-1310SM)
GbE very long-reach,
Single-Mode PTM, supports Ethernet, LCtype connectors, OSP
Hardened
(GbE/FC/2FC-1310)
ESCON, Multi-Mode
PTM, LC-type connectors
Apparatus Code Slot(s)
100BASE-LX-I1 LNW78
100BASE-LX-I1 LNW70/74
ESCON-MM-I1
(ESCON)
LNW73/73C
6.0
5.0
1000BASE-ZX-I1 LNW63/64/70/78 6.0
5.1
Release
Failure Rate in CO
(FIT)
545
Failure Rate in
1090
RT
(FIT)
545
500
392
1090
TBD
NA
Equipment Failure Rates
The table below provides the failure rates for DMX hardware.
Equipment
Standard Shelf Assembly
Cooling Unit (standard shelf)
High-capacity Shelf Assembly
Cooling Unit (high-capacity shelf)
Failure Rate in CO (FIT)
1149
2156
1622
4016
Failure Rate in RT (FIT)
NA
NA
3244
8032
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
9 - 9
Reliability and Quality
Sparing Information
............................................................................................................................................................................................................................................................
Overview
This section provides guidelines and a procedure to determine the number of spares needed at each location. The number of spares for each field replaceable unit (FRU) must be determined and maintained separately, based on that FRU’s in-service population at each given location.
Lead Time
Lead time, or turnaround time is the elapsed time between a known
FRU failure at a given service location and the arrival of a repaired (or new) FRU at the location where spare circuit packs are stocked to maintain a spare FRU level consistent with the population in service.
Important!
The number of spares for each code must be determined and maintained separately, based on the in-service population of the code at each location.
Lead time should not be confused with mean time to repair, which is the elapsed time between discovery of the failure of an inservice FRU and when a replacement is put into service.
...........................................................................................................................................................................................................................................................
9 - 1 0
365-372-300
Issue 8.0, September 2006
Reliability and Quality
Sparing Graph
............................................................................................................................................................................................................................................................
Overview
This section provides guidelines and a procedure to determine the number of spares needed at each location. The number of spares for each circuit pack or port unit code must be determined and maintained separately, based on that code’s in-service population at each given location.
Using the sparing graph
Use the following procedure to determine how many spare circuit packs, port units, or other pieces of equipment are required for each code at each location to maintain 99.9% service continuity, given a 10day lead time.
...........................................................................................................................................................................
1
Locate the failure rate for the unit under consideration using the tables above.
...........................................................................................................................................................................
2
Refer to the figure on the following page and select the curve that represents the nearest failure rate. Interpolation may be necessary.
...........................................................................................................................................................................
3
Follow the curve until it intersects the vertical line that represents the number of units in service at the given location. Interpolation may be necessary.
...........................................................................................................................................................................
4
Refer to the horizontal line immediately above the intersection. The number associated with this line is the minimum number of spares recommended for that location.
...........................................................................................................................................................................
5
Repeat steps 1-4 for each circuit pack, port unit, and type of equipment listed in the tables above.
E
N D O F S T E P S
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
9 - 1 1
Sparing Graph
Reliability and Quality
Example of using the graph
If there are 100 LNW46 OC-12 OLIU port units (failure rate of 3111) in service at a given location and your lead time is 10 days, then you should order and stock 3 spare OC-12 OLIUs port units for that location.
Sparing graph for 10-day lead time
Use the graph below to plan the number of spares necessary for the circuit packs and equipment used in DMX.
Figure 9-1 Sparing Graph for a 10-Day Lead Time
CP FITs (in thousands)
10
9
8
7
6
5
4
3
30
28
26
24
22
20
18
16
14
12
10
8
6
4
2
0
10 20 30 10
2
10
3
1 2 3
Number of Circuit Pack/Equipment in Service
10
4
2
1
2x10
4
...........................................................................................................................................................................................................................................................
9 - 1 2
365-372-300
Issue 8.0, September 2006
Reliability and Quality
International Standards Organization (ISO) Certification
............................................................................................................................................................................................................................................................
Overview
Various business units within Lucent Technologies have been certified to ISO 9001 and TL 9000 in past years. Lucent Technologies has moved to one quality management system for the entire company. The
Lucent Management System (LMS) achieved TL 9000 certification in
2004. DMX is certified to this quality standard as part of LMS. This certification includes ISO certification.
TL9000
TL 9000 is a telecommunications industry-specific set of requirements and measurements for software, hardware and services. TL 9000 is built on existing industry standards, including ISO 9001.
Conformance to TL 9000 constitutes conformance to corresponding
ISO 9001 requirements. TL 9000 consolidates various industry requirements and customer requests for measurements; it reduces problems caused by multiple requirements and audits; and it standardizes reporting and use of supplier performance data via defined measurements. TL 9000 requires well-documented and implemented controls for design development, production, delivery, installation, and service. Its purpose is to ensure manufacturers produce products with consistently high levels of quality and service.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
9 - 1 3
Reliability and Quality
Warranty
............................................................................................................................................................................................................................................................
Hardware warranty
Lucent Technologies provides a one year hardware warranty on the
DMX Access Multiplexer, effective from the date the unit is shipped.
Lucent Technologies provides two contacts for hardware failure emergencies. The Repair and Return line is to be used whenever a piece of equipment has failed to the point that it requires repairs, or must be replaced. The only times the Hotline is to be used is in the event of a service outage or during the initial installation and turn-up of the DMX.
• Repair and Return: 1-800-255-1402
• Emergency Hotline: 1-800-869-6757
Lucent also provides one year of access to LWS On-Line Customer
Support web-site (http://www.lucent.com/solutions/lws.html). Any
3rd- party vendor warranty terms will be pass-through from original vendor.
Software warranty
Lucent Technologies offers a 90 day warranty for defect resolution. All warranties pertain to the deployment of a release and do not apply to individual software licenses. For more warranty information, contact your local Lucent Technologies Account Executive.
Lucent’s warranty on any software release will not exceed 90 days for defect resolution. All warranties pertain to the deployment of a release and do not apply to individual software licenses.
For more warranty information, contact your local Lucent
Technologies Account Executive.
...........................................................................................................................................................................................................................................................
9 - 1 4
365-372-300
Issue 8.0, September 2006
Warranty
Reliability and Quality
Recycling / take-back / disposal of product
Electronic products bearing or referencing the symbol shown below when put on the market within the European Union, shall be collected and treated at the end of their useful life, in compliance with applicable
European Union and local legislation. They shall not be disposed of as part of unsorted municipal waste. Due to materials that may be contained in the product, such as heavy metals or batteries, the environment and human health may be negatively impacted as a result of inappropriate disposal.
Figure 9-2 Take Back Symbol
In the European Union, a solid bar under the crossed-out wheeled bin indicates that the product was put on the market after 13 August 2005.
Moreover, in compliance with legal requirements and contractual agreements, where applicable, Lucent Technologies will offer to provide for the collection and treatment of Lucent Technologies products at the end of their useful life, or products displaced by Lucent
Technologies equipment offers.
For information regarding take-back of equipment by Lucent
Technologies, or for more information regarding the requirements for recycling/disposal of product, please contact your Lucent Account
Manager or Lucent Takeback Support [email protected].
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
9 - 1 5
Warranty
Reliability and Quality
...........................................................................................................................................................................................................................................................
9 - 1 6
365-372-300
Issue 8.0, September 2006
10 Technical Specifications
Overview
............................................................................................................................................................................................................................................................
Purpose
This section contains the technical specifications for the DMX Access
Multiplexer.
Contents
This chapter contains the following sections:
Multimode Fiber Transmission with OC-3 and OC-12 circuit packs
Ethernet/SAN Optical Specifications
External Equipment Specifications
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 0 - 1
Overview
Technical Specifications
Transmission interface standards
The table below lists the electrical and optical transmission standards for SONET, Ethernet, and SAN interfaces.
Table 10-1 Transmission Interface Standards
Interface
E1
DS1/DS3/EC-1
OC-3/OC-12/OC-48/
OC-192
100BASE-TX, 100BASE-LX
1000BASE-SX and
1000BASE-LX
Standard
ITU G.703, G.704, G.706, G.736,
G.775, M.2100
ANSI T1.231-1997
GR-499-CORE, Issue 2, 1998
GR-253-CORE, Issue 3, 2000
GR-496-CORE, Issue 1, 1998
GR-1400-CORE, Issue 3, 2001
ANSI T1.231-1997
IEEE 802.3
IEEE 802.1D and 802.1Q
ITU G.7041, ITU G.707
Comments
B8ZS/AMI option, SF/ESF (DS1)
VMR, VM, or clear channel (DS3)
VC-12
FICON/ESCON/Fibre-Channel
ITU M.2101, ITU G.707
ITU G.7041,
SA22-7202-02, SA23-0394-03,
SG24-4662-00,
ANSI X3.296-1977
ANSI INCITS 352-2002
...........................................................................................................................................................................................................................................................
1 0 - 2
365-372-300
Issue 8.0, September 2006
Technical Specifications
Electrical Interfaces
Overview
............................................................................................................................................................................................................................................................
Purpose
This section contains the technical specifications for the low-speed electrical interfaces.
Contents
This section provides information on the following interfaces:
28DS1 (LNW6), 28DS1PM (LNW7), and 56 DS1/E1
12DS3/EC1 (LNW16) and 48DS3/EC1 (LNW19/19B)
10/100T (10/100 Mbps) Ethernet (LNW66 and LNW71)
10/100BASE-TX (10/100 Mbps) Ethernet (LNW74)
Electrical PTM 100/1000BASE-TX (100/1000 Mbps)
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 0 - 3
Technical Specifications
28DS1 (LNW6), 28DS1PM (LNW7), and 56 DS1/E1 (LNW8)
............................................................................................................................................................................................................................................................
Overview
The LNW6 and LNW7 are not supported when the LNW59 VLF Main pack, introduced in R7.0, is used. However, they are supported by all other Main interface circuit packs from previous releases.
Electrical specification DS1
The DS1 low-speed interface transmits and receives a standard electrical DS1 signal as specified in GR-499-CORE (1.544 Mb/s nominal rate, DSX-1 interconnect specification). Line coding is provisionable per DS1 port to alternate mark inversion (AMI) or AMI with bipolar 8-zero substitution (B8ZS).
Electrical specification E1
The E1 low-speed interface transmits and receives a standard electrical
E1 signal as specified in ITU G.703, G.704, G.706, G.736,
G.775, M.2100
(1.544 Mb/s nominal rate, DSX-1 interconnect specification).
Format specification
The LNW6/7/8/112 can be provisioned for the following DS1 formats: unframed (UF), superframe (SF), or extended superframe (ESF) as specified in GR-499-CORE, Section 10. In the case of SF or ESF format selections, DS1 performance monitoring information is collected by monitoring the associated DS1 framing format per ANSI
T1.231-1997.
Alarm thresholding
The following parameters are monitored on the DS1 interfaces:
• Loss of signal (LOS): 28DS1 + 28DS1PM + 56DS1/E1
• Bit error rate threshold (BER) based on line coding violations
(CV-L)
The alarm level for the monitored parameters can be provisioned to critical (CR), major (MJ), minor (MN), not alarmed or status conditioned (NA), not reported (NR).
DS1/E1 Transmission
Length
When transmitting DS1/E1 signals to a DSX panel, the Approximate
Span Length is 655 feet.
When transmitting DS1 signals to another DS1 terminating device the
Approximate Span Length is 1110 feet.
Loopbacks
The following loopbacks are supported on the LNW6/7/8 interfaces:
• Per-port DS1/E1 facility loopback
• Per-port DS1/E1 terminal loopback.
...........................................................................................................................................................................................................................................................
1 0 - 4
365-372-300
Issue 8.0, September 2006
28DS1 (LNW6), 28DS1PM (LNW7), and 56 DS1/E1 (LNW8)
Technical Specifications
Line build-outs (LBOs)
Line build-outs are software-provisionable. The maximum distance depends on the cable type (maximum 665 feet).
Performance monitoring
PM data is reported for DS1/E1 signals when DMX is equipped with the LNW7/8 circuit packs.
For a detailed list of PM parameters and thresholds, refer to Appendix
B of this document.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 0 - 5
Technical Specifications
12DS3/EC1 (LNW16) and 48DS3/EC1 (LNW19/19B)
............................................................................................................................................................................................................................................................
Electrical specification
(DS3)
The low-speed DS3 interfaces transmit/receive a standard electrical
DS3 signal as specified in GR-499-CORE, Section 9 (44.736 Mb/s rate,
DSX-3 interconnect specification, bipolar 3-zero substitution (B3ZS) encoding). However, the signal does not have to contain a standard
DS3 frame.
Electrical specification
(EC-1)
The EC-1 low-speed interfaces provide transport of any STS-1 signal compatible with the electrical STS-1 interface specification in
GR-253-CORE, Issue 3. The EC-1 low-speed port can be provisioned to provide STS-1 path termination functions for a VT1.5 structured
STS-1 with an asynchronous DS1 mapping.
The low-speed EC-1 interfaces transmit/receive a standard electrical
EC-1 signal as specified in GR-253-CORE, Issue 3 (51.844 Mb/s rate,
STSX-1 interconnect specification, bipolar 3-zero substitution (B3ZS) encoded and scrambled).
DS3/EC-1 Port Provisioning
The LNW16 and LNW19 circuit packs enable you to provision DS3 or
EC-1 service on a per-port basis. Thus, one of these circuit packs can host a variety of DS3 or EC-1 traffic.
DS3/EC-1 Transmission
Length
When transmitting DS3/EC1 signals to a DSX panel, the Approximate
Span Length is 450 feet.
When transmitting DS3/EC1 signals to another DS3 terminating device
(such as a DMX) the Approximate Span Length is 900 feet.
...........................................................................................................................................................................................................................................................
1 0 - 6
365-372-300
Issue 8.0, September 2006
Technical Specifications
DS3 TransMUX (LNW18)
............................................................................................................................................................................................................................................................
Electrical specification
The TransMUX circuit pack provides 12 ports for DS3 service.
DS3 interfaces transmit/receive a standard electrical DS3 signal as specified in GR-499-CORE, Section 9 (44.736 Mb/s rate, DSX-3 interconnect specification, bipolar 3-zero substitution (B3ZS) encoding).
Trans/MUX circuit pack
DS1 and DS3 signals
DMX supports a 12-port Trans/MUX card that can collect various DS1 signals from around a ring and combine them into a channelized DS3 signal.
The Trans/MUX circuit pack functions in the following manner:
Transmit Functions
• Receives a B3ZS-encoded DS3 signal from a DSX-3
• Recovers DS3 clock and NRZ data
• Calculates parity errors on the DS3 input
• Demultiplexes the M13 or C-bit formatted DS3 signal into 28
DS1s
• Maps the 28 DS1s into VT1.5s and then into an STS-1
• Inserts STS-1 path overhead
• Provides the STS-1 signal to the OLIU circuit packs
Receive Functions
• Interprets the STS-1 pointer values
• Terminates the STS-1 path
• Disinterleaves the STS-1 signal into 28 VT1.5s and interprets VT pointer values
• Converts the VT1.5 signals to 28 DS1 signals
• Multiplexes the 28 DS1 signals to an M13 or C-bit formatted DS3 signal
• B3ZS encodes the outgoing DS3 signal
• Pre-equalizes the DS3 signal (with LBO) and transmits it to a
DSX-3
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 0 - 7
Technical Specifications
48DS3/EC1/TransMUX (LNW20)
............................................................................................................................................................................................................................................................
Electrical specification
DS3 interfaces transmit/receive a standard electrical DS3 signal as specified in GR-499-CORE, Section 9 (44.736 Mb/s rate, DSX-3 interconnect specification, bipolar 3-zero substitution (B3ZS) encoding).
The LNW20 provides 48 ports supporting DS3, EC1, and TMUX functionality on a port-by-port basis. Each port can be individually provisioned as DS3 or EC1 (unchannelized), or as TransMUX
(channelized DS3s). With the LNW20, one high-density pack can be used for all DS3, EC1, and/or TransMUX applications.
LNW20 can be 1x1 protected or function in 0x1 unprotected mode. It supports hairpins to other packs in the shelf, and between ports on the same pack. LNW20 can occupy slots A1/A2 through G1/G2 when the
LNW59 VLF Main is used. LNW20 only functions in portless mode in
G1/G2. When the LNW20 is used with non-VLF Mains, it can not occupy G1/G2.
Ported chanelized DS3 mode of operation
The LNW20 Trans/MUX card that can collect various DS1 signals from around a ring and combine them into a channelized DS3 signal.
The Trans/MUX capability performs in the following manner:
Transmit Functions
• Receives a B3ZS-encoded DS3 signal from a DSX-3
• Recovers DS3 clock and NRZ data
• Calculates parity errors on the DS3 input
• Demultiplexes the M13 or C-bit formatted DS3 signal into 28
DS1s
• Maps the 28 DS1s into VT1.5s and then into an STS-1
• Inserts STS-1 path overhead
• Provides the STS-1 signal to the OLIU circuit packs
Receive Functions
• Interprets the STS-1 pointer values
• Terminates the STS-1 path
• Disinterleaves the STS-1 signal into 28 VT1.5s and interprets VT pointer values
• Converts the VT1.5 signals to 28 DS1 signals
...........................................................................................................................................................................................................................................................
1 0 - 8
365-372-300
Issue 8.0, September 2006
48DS3/EC1/TransMUX (LNW20)
Technical Specifications
• Multiplexes the 28 DS1 signals to an M13 or C-bit formatted DS3 signal
• B3ZS encodes the outgoing DS3 signal
• Pre-equalizes the DS3 signal (with LBO) and transmits it to a
DSX-3
Unchannelized DS3 operation
The low-speed DS3 interfaces transmit/receive a standard electrical
DS3 signal as specified in GR-499-CORE, Section 9 (44.736 Mb/s rate,
DSX-3 interconnect specification, bipolar 3-zero substitution (B3ZS) encoding). However, the signal does not have to contain a standard
DS3 frame.
EC-1 operation
The EC-1 low-speed interfaces provide transport of any STS-1 signal compatible with the electrical STS-1 interface specification in
GR-253-CORE, Issue 3. The EC-1 low-speed port can be provisioned to provide STS-1 path termination functions for a VT1.5 structured
STS-1 with an asynchronous DS1 mapping.
The low-speed EC-1 interfaces transmit/receive a standard electrical
EC-1 signal as specified in GR-253-CORE, Issue 3 (51.844 Mb/s rate,
STSX-1 interconnect specification, bipolar 3-zero substitution (B3ZS) encoded and scrambled).
DS3 portless mode of operation
The LNW20 can also function in portless mode. Portless mode does not utilize any of the electrical ports on the pack. When operating in portless mode, LNW20 converts channelized DS3 signals that enter
DMX on a SONET STS-1 interface (on another pack) to VT mapped
STS-1s. This VT-mapped STS-1 is cross-connected at the VT level in the Main packs (at least one side of the cross-connect is OCn/EC1) to any interface that supports the signal structure today (DS1, channelized
DS3, EC1, optical). Portless mode can be provisioned on a per-port basis when VLF Mains are used. When non-VLF Mains are used, odd numbered ports can be configured as portless and the corresponding even-numbered port will be unavailable for service.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 0 - 9
Technical Specifications
10/100T (10/100 Mbps) Ethernet (LNW66 and LNW71)
............................................................................................................................................................................................................................................................
Electrical specification
These 10/100T circuit packs provide a 24-port, 100BASE-TX, IEEE
802.3-compliant interface that is capable of spanning distances of 100 meters. The 10/100T port performs protocol transparent filtering and bridging of incoming media access control (MAC) frames. MAC frames with a destination address on the local bus are filtered by the
10/100T circuit packs to prevent unnecessary transmission of frames over the wide area network (WAN). The 10/100T interface auto-negotiates mode (full/half duplex) and speed (10/100 Mbps) when interfacing with other 802.3-compliant devices over twisted pair media.
The 10/100T circuit packs must be housed in slot 1 of a Function Unit group and are not equipment protected. However, facility protection can be provided through the WAN via SONET (UPSR, BLSR, or 1+1) and/or (on the LNW66) through the IEEE 802.1W spanning tree algorithm.
The 10/100T Ethernet interfaces comply with the following transmission standards:
• standard IEEE 802.1D for transparent bridging and spanning tree protection.
• standard IEEE 802.3, Section 25 for 10/100 Mb autonegotiation
(including flow control, full-duplex transmission, and half-duplex transmission).
Important!
The LNW71 is being DA’d and will no longer be available as of 3/1/08.
Format specification
The 10/100T circuit packs comply with the following formatting standards:
•
Maximum frame size refer to Packet size in different tagging modes (A-86)
• standard IEEE 802.1Q VLANs
• Ethernet to SONET Mapping, (G.7041 (GFP) and G.707 (Virtual
Concatenation))
• Protection (SONET and/or 802.1W) and Ethernet Bridging
(802.1D)
...........................................................................................................................................................................................................................................................
1 0 - 1 0
365-372-300
Issue 8.0, September 2006
10/100T (10/100 Mbps) Ethernet (LNW66 and LNW71)
Technical Specifications
Performance monitoring
Performance monitoring capabilities are available on the 10/100T circuit packs. A detailed list of monitored parameters can be found in
Appendix B of this document.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 0 - 1 1
Technical Specifications
100/1000BASE-TX (10/100 Mbps) Ethernet (LNW70)
............................................................................................................................................................................................................................................................
Electrical specification
The LNW70 uses electrical PTMs that are provisionable to support either 100BASE-T or 1000BASE-T traffic. The electrical PTMs can occupy ports 1-4.
The dual function electrical PTM is provisionable for 100 or 1000
Mbps traffic. It conforms to the IEEE802.3 standards for 100BASE-T and 1000BASE-T in its respective settings (IEEE802.3z and
IEE802.3ab). Connectivity is provided for an RJ-45 Cat 5 cable and the
PTM has a maximum span length of 100 meters. When the LNW70 is installed in slots G1 or G2, only the optical PTMs can be used.
For more information on the PTM optics available for the LNW70 refer
Electrical PTM 100/1000BASE-TX (100/1000 Mbps)
and
GbE (1000BASE-X)/ Fast-E (100BASE-LX/TX)
Optical/Electrical Ethernet (LNW70)
The LNW70 circuit pack can also support four 1000BASE-X (SX, LX, and/or ZX— very long reach 80km), IEEE 802.3-compliant
(1000Mbps) GbE interfaces and four 100BASE-LX IEEE
802.3-compliant (100 Mbps) fast Ethernet interfaces. The LNW70 circuit pack performs protocol transparent filtering and bridging of incoming media access control (MAC) frames. MAC frames with a destination address on the local bus are filtered by the LNW70 to prevent unnecessary transmission of frames over the wide area network
(WAN).
The LNW70 is an unprotected pack by default. R7.0 incorporates support of Link Aggregation on LNW70 LAN ports, which can be used to provide facility protection. For more information on Link
Aggregation, refer to
Link Aggregation on LNW70 LAN ports
.
Prior to R7.0, the LNW70 could only occupy slot 1 of any Function
Unit group on the shelf (including Growth slots), and up to 20
1000BASE-X and 20 100BASE-LX ports were addressable when all
Function Unit groups are equipped with LNW70 circuit packs.
When DMX is equipped with VLF Main (LNW59) packs, Ethernet packs can occupy both Slot 1 and 2 of a Function or Growth Unit
(where applicable). With VLF Mains and all tributary slots populated with LNW70 packs, up to 40 1000BASE-X and 40 100BASE-LX ports are addressable. When LNW70 is installed in slots G1 or G2, only optical PTMs can be used. DMX also does not allow packs with electrical interfaces to be installed in adjacent slots within the same
...........................................................................................................................................................................................................................................................
1 0 - 1 2
365-372-300
Issue 8.0, September 2006
100/1000BASE-TX (10/100 Mbps) Ethernet (LNW70)
Technical Specifications
Function or Growth unit next to another pack with Electrical interfaces.
Therefore, if slots A1/2 through D1/2 are equipped with LNW70 packs using electrical PTMs, up to 32 electrical 100/1000BASE-TX ports are addressable.
Prior to Release 7.0 (and when VLF Mains are not used), if the LNW70 circuit packs occupy slot 1 of a Function Unit group, slot 2 must be populated with an apparatus blank.
The LNW70 features Pluggable Transmission Module (PTM) electrical and optical interfaces. PTMs are “pluggable” in the sense that they can be plugged into a circuit pack as they become necessary. This allows customers to grow their network incrementally, only realizing the full cost for optics as the need to provision service on (and thus receive revenue from) them becomes necessary. LNW70 packs are purchased and shipped with no ports populated with functioning optics. The ports remain empty until the customer decides to place interfaces in them.
4- ports are available for 1000BASE-X (SX and/or LX) optics or
100/1000BASE-TX electrical interfaces and 4 ports are available for
100BASE-LX optics.
The 100/100BASE-TX Ethernet interfaces comply with the following transmission standards:
• standard IEEE 802.1D for transparent bridging and spanning tree protection.
• standard IEEE 802.3, Section 25 for 10/100 Mb autonegotiation
(including flow control, full-duplex transmission, and half-duplex transmission).
Format specification
The LNW70 complies with the following formatting standards:
•
Maximum frame size refer to Packet size in different tagging modes (A-86)
• standard IEEE 802.1Q VLANs
• Ethernet to SONET Mapping, (G.7041 (GFP) and G.707 (Virtual
Concatenation))
• Protection (SONET and/or 802.1W) and Ethernet Bridging
(802.1D)
Performance monitoring
Performance monitoring capabilities are available on the 10/100T circuit packs. A detailed list of monitored parameters can be found in
Appendix B.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 0 - 1 3
Technical Specifications
10/100BASE-TX (10/100 Mbps) Ethernet (LNW74)
............................................................................................................................................................................................................................................................
Electrical specification
The LNW74 provides 8-ports for optical 100BASE-LX transport at
100 Mbps using standard Ethernet switching IEEE 802.1, standard encapsulation according to ANSI T1X1.5/2000-024R4 (ITU G.7041), and standard STS-1 and VT VCAT according to ITU G.707.
For more information on the PTM optics available for the LNW74 refer to the section entitled
10/100T (10/100BASE-T)/ Fast-E (100BASE-LX)
Electrical/Optical Ethernet Private Line (LNW74)
The LNW74 also provides 16 electrical ports for the 10/100BASE-TX interfaces. These electrical ports transmit at 10/100 Mbps using standard Ethernet switching IEEE 802.1, standard encapsulation according to ANSI T1X1.5/2000-024R4 (ITU G.7041), and standard
STS-1 and VT virtual concatenation according to ITU G.707. The
LNW74 electrical interfaces can transmit signals across spans as long as 100 meters. The LNW74 is an unprotected pack.
The LNW74 circuit pack is designed specifically to support Fast
Ethernet Private Line applications. Each LNW74 circuit pack can support 24 private lines. The LNW74 can also support STS-3(c) cross connections instead of virtual concatenation.
The 10/100T Ethernet interfaces comply with the following transmission standards:
• standard IEEE 802.1D for transparent bridging and spanning tree protection.
• standard IEEE 802.3, Section 25 for 10/100 Mb autonegotiation
(including flow control, full-duplex transmission, and half-duplex transmission).
In R7.0, with use of true 0x1 and LNW59 VLF Main packs, Ethernet packs can be installed in either slot 1 or 2 of Function Unit or Growth groups. DMX does not allow electrical interface packs to occupy adjacent slots within the same Function or Growth unit next to other electrical interface packs. Therefore, two LNW74s can not be installed within the same group. However, beginning in R7.0 (and when VLF
Mains are used), LNW74 can be installed next to another optical TDM or Ethernet pack with in the same group (ex. LNW74 and LNW67 or
LNW32).
Prior to Release 7.0 (and when VLF Mains are not used), if the LNW74 circuit packs occupy slot 1 of a Function Unit group, slot 2 must be populated with an apparatus blank.
...........................................................................................................................................................................................................................................................
1 0 - 1 4
365-372-300
Issue 8.0, September 2006
10/100BASE-TX (10/100 Mbps) Ethernet (LNW74)
Technical Specifications
Format specification
The LNW74 complies with the following formatting standards:
• Maximum frame size refer to
Packet size in different tagging modes
• standard IEEE 802.1Q VLANs
• Ethernet to SONET Mapping, (G.7041 (GFP) and G.707 (Virtual
Concatenation))
• Protection (SONET and/or 802.1W) and Ethernet Bridging
(802.1D)
Performance monitoring
Performance monitoring capabilities are available on the LNW74. A detailed list of monitored parameters can be found in Appendix B.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 0 - 1 5
Technical Specifications
Electrical PTM 100/1000BASE-TX (100/1000 Mbps) Ethernet
(LNW63/64/70)
............................................................................................................................................................................................................................................................
Electrical specification Electrical Fast Ethernet/GbE PTM for LNW63/64/70
The LNW63/64/70 now support a dual function electrical Pluggable
Transmission Module (PTM), also known as SFP, that is provisionable for 100 or 1000 Mbps traffic. On the LNW70, the PTM can function at both 100 and 1000BASE-TX rates. On the LNW63 and LNW64, only the 1000BASE-TX rate is supported.
The electrical Ethernet PTM conforms to the IEEE802.3 standards for
100BASE-T and 1000BASE-T in its respective settings (IEEE802.3z and IEE802.3ab). Connectivity is provided for an RJ-45 Cat 5 cable and the PTM has a maximum span length of 100 meters.
For more information on the PTM optics available for the Ethernet circuit packs refer to the section entitled
. For more information on the LNW63, LNW64, and
LNW70 packs themselves, refer to the following sections:
100/1000BASE-TX (10/100 Mbps) Ethernet (LNW70)
(1000BASE-TX and/or 1000BASE-SX/LX/ZX) Private Line Optical Ethernet
8-port GbE PTM (1000BASE-TX and/or 1000BASE-SX/LX/ZX)
Private Line Optical Ethernet (LNW64)
(100BASE-LX/TX) Optical/Electrical Ethernet (LNW70)
The 100/100BASE-TX Ethernet interfaces comply with the following transmission standards:
• standard IEEE 802.1D for transparent bridging and spanning tree protection.
• standard IEEE 802.3, Section 25 for 10/100 Mb autonegotiation
(including flow control, full-duplex transmission, and half-duplex transmission).
Performance monitoring
Performance monitoring capabilities are available on the 10/100T circuit packs. A detailed list of monitored parameters can be found in
Appendix B.
...........................................................................................................................................................................................................................................................
1 0 - 1 6
365-372-300
Issue 8.0, September 2006
Technical Specifications
TDM Optical Interfaces
Overview
............................................................................................................................................................................................................................................................
Purpose
This section contains technical specifications for the low- and high-speed DMX TDM optical interfaces.
Contents
The following optical interfaces are discussed in this section:
Quad OC-3 Low-speed OLIU (LNW36)
Quad OC-3 Low-speed OLIU (LNW37)
8-port OC-3 Low-speed OLIU (LNW45)
Dual OC-12 Low-speed OLIU (LNW46)
Quad OC-12 Low-speed OLIU (LNW49)
OC-48 OLIU (DWDMs, LNW26B, LNW27, LNW28,
LNW29, LNW31, LNW32, LNW62, LNW76, and LNW77)
OC-192 OLIUs (LNW56, LNW57, LNW58, LNW59,
LNW60, LNW523, LNW527, LNW554, and LNW555)
SONET Optical Specifications: OC-3 and OC-12 Low-speed
SONET Optical Specifications: OC-12 High-speed OLIUs
SONET Optical Specifications: OC-3 OLIUs (LNW37 and
LNW45) with PTM pluggable optics
SONET Optical Specifications: OC-12 OLIUs (LNW49) with PTM pluggable optics
SONET Optical Specifications: OC-48 OLIUs (LNW26B,
SONET Optical Specifications: OC-48 OLIU (LNW62)
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 0 - 1 7
Overview
SONET Optical Specifications: OC-48 OLIU (LNW76 and
SONET Optical Specifications: OC-48 Low-Speed OLIU
OC-48 DWDM Optical Specification
(LNW121B-LNW159B, LNW221-LNW259, and
SONET Optical Specifications: OC-192 OLIU (LNW59)
SONET Optical Specifications: OC-192 OLIU (LNW56 and
SONET Optical Specifications: OC-192 OLIU (LNW57 and
DWDM OC-192 OLIUs (LNW523, LNW527, LNW554, and
Technical Specifications
...........................................................................................................................................................................................................................................................
1 0 - 1 8
365-372-300
Issue 8.0, September 2006
Technical Specifications
Quad OC-3 Low-speed OLIU (LNW36)
............................................................................................................................................................................................................................................................
Optical specification
The LNW36 OLIU optics meet or exceed SONET OC-3, long-reach specifications (SONET LR-1 DFB). The distributed feedback (DFB) laser transmitter supplies a 1310 nm, scrambled non-return-to-zero
(NRZ) coded signal (155.52 Mb/s).
The LNW36 OLIU long reach OC-3 interface supports span lengths up to 55 km and is OSP hardened. Refer to
OC-3 and OC-12 Low-speed OLIUs (LNW36, LNW46)
detailed system, transmitter, receiver, and link budget specifications.
The LNW36 is being DA’d and will no longer be available as of
12/31/07.
Alarm thresholding
The following parameters are monitored on the OC-3 interface:
• LOS
• LOF
• AIS-L
• RFI-L (FERF)
• Signal degrade (BER)
• Signal fail (BER).
Performance monitoring
SONET line and path performance monitoring complies with the standards outlined in GR-253-CORE. For detailed PM parameter thresholds on the OC-3 interface, refer to Appendix B of this document.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 0 - 1 9
Technical Specifications
Quad OC-3 Low-speed OLIU (LNW37)
............................................................................................................................................................................................................................................................
Optical specification
The LNW37 OLIU uses Pluggable Transmission Module (PTM) optics, also known as SFP optics, and is OSP hardened. PTM optics can be
“plugged” into the circuit pack as they become needed. Because the optics are pluggable, different ranges are available. The LNW37 can be equipped with OC-3 SR-1, IR-1 or LR-1 optics. These optics meet standard optical specs per Telcordia GR-253. and ITU G.957.
The multi-longitudinal-mode/Fabry-Perot (FP) laser is used for short or intermediate-reach transmission. Either a FP or a single-longitudinal- mode/distributed feedback (DFB) laser transmitter is employed in long-reach applications. The PTM optics for the LNW37 supply a 1310 nm, scrambled non-return-to-zero (NRZ) coded signal (155.52 Mb/s).
When equipped with SR-1 PTM optics, the LNW37 can span distances of 2 km.
When equipped with IR-1 PTM optics, the LNW37 can span distances of 20 km.
When equipped with the LR-1 PTM optics, the LNW37 can span distances of 55 km.
Refer to
SONET Optical Specifications: OC-3 OLIUs (LNW37 and LNW45) with PTM pluggable optics
in this chapter for detailed system, transmitter, receiver, and link budget specifications.
...........................................................................................................................................................................................................................................................
1 0 - 2 0
365-372-300
Issue 8.0, September 2006
Quad OC-3 OLIU (LNW37)
Technical Specifications
Allowed Optics
The table below lists the PTM optics, also known as SFP optics, that may be used in the LNW37 circuit pack.
DMX utilizes Pluggable Transmission Module (PTM) optics on the
LNW37 circuit pack. To ensure proper optical performance, mechanical fit, compliance with EMC, and compliance with laser safety standards, the Lucent specified PTM transceivers listed in the table below must be used.
Only the Lucent specified PTM transceivers listed below are compatible with DMX software. If non-Lucent specified PTM transceivers are installed in DMX, the system will reject that transceiver, and that optical port will become inoperable (until approved parts are installed).
Table 10-2 PTM Optics for LNW37
Apparatus Code
S155I2
(OC3SR1-I1)
OC3IR1-I1
Comcode
109602599
109453894
Description
OC3 PTM TRCVR
Short Reach, SR-1
OC3 PTM TRCVR
Intermediate Reach, IR-1
OC3LR1-I1 109453886
Long Reach, LR-1
Alarm thresholding
The following parameters are monitored on the OC-3 interface:
• LOS
• LOF
• AIS-L
• RFI-L (FERF)
• Signal degrade (BER)
• Signal fail (BER).
Performance monitoring
SONET line and path performance monitoring complies with the standards outlined in GR-253-CORE. For detailed PM parameter thresholds on the OC-3 interface, refer to Appendix B of this document.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 0 - 2 1
Technical Specifications
8-port OC-3 Low-speed OLIU (LNW45)
............................................................................................................................................................................................................................................................
Optical specification
The LNW45 OLIU uses Pluggable Transmission Module (PTM) optics and is OSP hardened. PTM optics can be “plugged” into the circuit pack as they become needed. Because the optics are pluggable, different ranges are available. The LNW45 can be equipped with either
OC-3 SR-1, IR-1 or LR-1 optics. These optics meet standard optical specs per Telcordia GR-253. and ITU G.957.
The multi-longitudinal-mode/Fabry-Perot (FP) laser is used for short or intermediate-reach transmission. Either a FP or a single-longitudinal- mode/distributed feedback (DFB) laser transmitter is employed in long-reach applications. The PTM optics for the LNW45 supply a 1310 nm, scrambled non-return-to-zero (NRZ) coded signal (155.52 Mb/s).
When equipped with SR-1 PTM optics, the LNW45 can span distances of 2 km.
When equipped with IR-1 PTM optics, the LNW45 can span distances of 20 km.
When equipped with the LR-1 PTM optics, the LNW45 can span distances of 55 km.
Refer to
SONET Optical Specifications: OC-3 OLIUs (LNW37 and LNW45) with PTM pluggable optics
in this chapter for detailed system, transmitter, receiver, and link budget specifications.
...........................................................................................................................................................................................................................................................
1 0 - 2 2
365-372-300
Issue 8.0, September 2006
8-port OC-3 Low-speed OLIU (LNW45)
Technical Specifications
Allowed Optics
The table below lists the PTM optics, also known as SFP optics, that may be used in the LNW45 circuit pack.
DMX utilizes Pluggable Transmission Module (PTM) optics on the
LNW45 circuit pack. To ensure proper optical performance, mechanical fit, compliance with EMC, and compliance with laser safety standards, the Lucent specified PTM transceivers listed in the table below must be used.
Only the Lucent specified PTM transceivers listed below are compatible with DMX software. If non-Lucent specified PTM transceivers are installed in DMX, the system will reject that transceiver, and that optical port will become inoperable (until approved parts are installed).
Table 10-3 PTM Optics for LNW45
Apparatus Code
S155I2
(OC3SR1-I1)
OC3IR1-I1
Comcode
109602599
109453894
Description
OC3 PTM TRCVR
Short Reach, SR-1
OC3 PTM TRCVR
Intermediate Reach, IR-1
OC3LR1-I1 109453886
Long Reach, LR-1
Alarm thresholding
The following parameters are monitored on the OC-3 interface:
• LOS
• LOF
• AIS-L
• RFI-L (FERF)
• Signal degrade (BER)
• Signal fail (BER).
Performance monitoring
SONET line and path performance monitoring complies with the standards outlined in GR-253-CORE. For detailed PM parameter thresholds on the OC-3 interface, refer to Appendix B of this document.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 0 - 2 3
Technical Specifications
Dual OC-12 Low-speed OLIU (LNW46)
............................................................................................................................................................................................................................................................
Optical specification
The LNW46 optics meet or exceed SONET OC-12, long-reach specifications (SONET LR-1). The distributed feedback laser (DFB) supplies a 1310 nm, scrambled NRZ-coded signal (622.08 Mb/s).
The LNW46 low-speed interface supports span lengths up to 53 km and is OSP hardened. Refer to the
SONET Optical Specifications: OC-3 and OC-12 Low-speed OLIUs (LNW36, LNW46)
detailed system, transmitter, receiver, and link budget specifications.
The LNW46 is being DA’d and will no longer be available as of
12/31/07.
Alarm thresholding
The following parameters are monitored at the low-speed OC-12 interface.
• LOF
• LOS
• AIS-L
• RFI-L (FERF)
• Signal Degrade (BER)
• Signal Fail (BER).
Performance monitoring
SONET line and path performance monitoring complies with the standards outlined in GR-253-CORE. For detailed PM parameter thresholds on the OC-12 interface, refer to Appendix B of this document.
...........................................................................................................................................................................................................................................................
1 0 - 2 4
365-372-300
Issue 8.0, September 2006
Technical Specifications
OC-12 High-speed OLIU (LNW48)
............................................................................................................................................................................................................................................................
Optical specification
The LNW48 optics meet or exceed SONET OC-12 intermediate-reach specifications (SONET OC-12 IR-1). The multi-longitudinal-mode/Fabry-Perot (FP) laser supplies a 1310 nm, scrambled NRZ-coded signal (622.08 Mb/s).
The LNW48 high-speed interface supports span lengths up to 20 km and is OSP hardened. Refer to the
SONET Optical Specifications: OC-12
High-speed OLIUs (LNW48, LNW50, and LNW54)
section in this chapter for detailed system, transmitter, receiver, and link budget specifications.
Alarm thresholding
The following parameters are monitored at the OC-12 high-speed
(Network-side) interface.
• LOF
• LOS
• AIS-L
• RFI-L (FERF)
• Signal Degrade (BER)
• Signal Fail (BER).
Performance monitoring
SONET line and path performance monitoring complies with the standards outlined in GR-253-CORE. For detailed PM parameter thresholds on the OC-12 high-speed interface, refer to Appendix B of this document.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 0 - 2 5
Technical Specifications
Quad OC-12 Low-speed OLIU (LNW49)
............................................................................................................................................................................................................................................................
Optical specification
The LNW49 OLIU uses Pluggable Transmission Module (PTM) optics.
PTM optics can be “plugged” into the circuit pack as they become needed. Because the optics are pluggable, different ranges are available. The LNW49 can be equipped with IR-1, LR-1, or LR-2 optics. These optics meet standard optical specs per Telcordia GR-253 and ITU G.957.
LNW49 is approved for OSP deployments.
The IR-1 optics available for this circuit pack also conform to SR-1 specifications. Thus, the LNW49 can also be employed in short reach applications.
The multi-longitudinal-mode/Fabry-Perot (FP) laser is used for short or intermediate-reach transmission. A single-longitudinal-mode/ distributed feedback (DFB) laser transmitter is employed in long-reach applications. The IR-1 and LR-1 PTM optics for the LNW49 supply a
1310 nm, scrambled non-return-to-zero (NRZ) coded signal (622.08
Mb/s). The LR-2 PTM optics for the LNW49 supply a 1550 nm, scrambled non-return-to-zero (NRZ) coded signal (622.08 Mb/s).
When equipped with IR-1 PTM optics, the LNW49 can span distances of 20 km.
When equipped with the LR-1 PTM optics, the LNW49 can span distances of 46 km.
When equipped with the LR-2 PTM optics, the LNW49 can span distances of 80 km.
Refer to the
SONET Optical Specifications: OC-3 OLIUs (LNW37 and
LNW45) with PTM pluggable optics
in this chapter for detailed system,
transmitter, receiver, and link budget specifications.
...........................................................................................................................................................................................................................................................
1 0 - 2 6
365-372-300
Issue 8.0, September 2006
Quad OC-12 Low-speed OLIU (LNW49)
Technical Specifications
Allowed Optics
The table below lists the PTM optics, also known as SFP optics, that may be used in the LNW49 circuit pack.
DMX utilizes Pluggable Transmission Module (PTM) optics on the
LNW49 circuit pack. To ensure proper optical performance, mechanical fit, compliance with EMC, and compliance with laser safety standards, the Lucent specified PTM transceivers listed in the table below must be used.
Only the Lucent specified PTM transceivers listed below are compatible with DMX software. If non-Lucent specified PTM transceivers are installed in DMX, the system will reject that transceiver, and that optical port will become inoperable (until approved parts are installed).
Table 10-4 PTM Optics for LNW49
Apparatus Code
OC12IR1-I1
OC12LR1-I1
OC12LR2-I1
Comcode
109453902
109467522
109604447
Description
OC12 PTM TRCVR
Intermediate Reach, IR-1
OC12 PTM TRCVR
Long Reach, LR-1
OC12 PTM TRCVR
Long Reach, LR-2
Alarm thresholding
The following parameters are monitored on the OC-12 interface:
• LOS
• LOF
• AIS-L
• RFI-L (FERF)
• Signal degrade (BER)
• Signal fail (BER).
Performance monitoring
SONET line and path performance monitoring complies with the standards outlined in GR-253-CORE. For detailed PM parameter thresholds on the OC-12 interface, refer to Appendix B of this document.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 0 - 2 7
Technical Specifications
OC-12 High-speed OLIU (LNW50)
............................................................................................................................................................................................................................................................
Optical specification
The LNW50 optics meet or exceed SONET OC-12 long-reach specifications (SONET OC-12 LR-1). The single-longitudinal-mode/distributed feedback laser (DFB) supplies a
1310 nm, scrambled NRZ-coded signal (622.08 Mb/s).
The LNW50 high-speed interface supports span lengths up to 53 km and is OSP hardened. Refer to the
SONET Optical Specifications: OC-12
High-speed OLIUs (LNW48, LNW50, and LNW54)
in this chapter for detailed system, transmitter, receiver, and link budget specifications.
Alarm thresholding
The following parameters are monitored at the OC-12 high-speed
(Network-side) interface.
• LOF
• LOS
• AIS-L
• RFI-L (FERF)
• Signal Degrade (BER)
• Signal Fail (BER).
Performance monitoring
SONET line and path performance monitoring complies with the standards outlined in GR-253-CORE. For detailed PM parameter thresholds on the OC-12 high-speed interface, refer to Appendix B of this document.
...........................................................................................................................................................................................................................................................
1 0 - 2 8
365-372-300
Issue 8.0, September 2006
Technical Specifications
OC-12 High-speed OLIU (LNW54)
............................................................................................................................................................................................................................................................
Optical specification
The LNW54 optics meet or exceed SONET OC-12 long-reach specifications (SONET OC-12 LR-2). The single-longitudinal-mode/distributed feedback laser (DFB) supplies a
1550 nm, scrambled NRZ-coded signal (622.08 Mb/s).
The LNW54 high-speed interface supports span lengths up to 81 km
and is OSP hardened. Refer to SONET Optical Specifications: OC-12
High-speed OLIUs (LNW48, LNW50, and LNW54): page 10-40 in
this chapter for detailed system, transmitter, receiver, and link budget specifications.
Alarm thresholding
The following parameters are monitored at the OC-12 high-speed
(Network-side) interface.
• LOF
• LOS
• AIS-L
• RFI-L (FERF)
• Signal Degrade (BER)
• Signal Fail (BER).
Performance monitoring
SONET line and path performance monitoring complies with the standards outlined in GR-253-CORE. For detailed PM parameter thresholds on the OC-12 high-speed interface, refer to Appendix B of this document.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 0 - 2 9
Technical Specifications
OC-48 OLIU (DWDMs, LNW26B, LNW27, LNW28, LNW29,
LNW31, LNW32, LNW62, LNW76, and LNW77)
............................................................................................................................................................................................................................................................
Overview
Refer to the following sections in this chapter for detailed system, transmitter, receiver, and link budget specifications.
•
SONET Optical Specifications: OC-48 OLIUs (LNW26B, LNW27,
•
SONET Optical Specifications: OC-48 OLIU (LNW62)
•
SONET Optical Specifications: OC-48 DWDM PTM Optical Specification
(LNW62)
•
SONET Optical Specifications: OC-48 OLIU (LNW76 and LNW77)
•
SONET Optical Specifications: OC-48 Low-Speed OLIU (LNW31)
•
OC-48 DWDM Optical Specification (LNW121B-LNW159B,
LNW221-LNW259, and LNW421-LNW459)
Optical specification LNW26B, LNW27, LNW28 and LNW32
The high-speed LNW26B, LNW27, LNW28, and LNW32 OC-48 meet or exceed SONET OC-48 1310 nm LR-1 specifications.
The LNW28 and LNW32 are hardened for outside plant (OSP) temperature ranges. The LNW28 will no longer be available as of
5/17/06.
These interfaces supports span lengths up to 51 km (LNW28 and
LNW32 support spans of 49 km in OSP environments).
LNW29
The high-speed LNW29 meets or exceeds SONET OC-48 1550 LR-2 specifications.
These interfaces supports span lengths up to 81 km.
LNW31 and LNW77
The low-speed LNW31 and high-speed LNW77 meet or exceed
SONET OC-48 1310 nm IR-1 specifications.
These interfaces support span lengths up to 20 km.
...........................................................................................................................................................................................................................................................
1 0 - 3 0
365-372-300
Issue 8.0, September 2006
OC-48 OLIU (DWDMs, LNW26B, LNW27, LNW28, LNW29,
LNW31, LNW32, LNW62, LNW76, and LNW77)
Technical Specifications
LNW62
The low-speed LNW62 provides 4 PTM (also known as SFP) ports capable of supporting 1.3LR-1 and 1.5LR-2 PTMs. The LR-1 PTMs conform to SONET OC-48 1310 nm LR-1 specifications. The LR-2
PTMs conform to SONET OC-48 1550 nm LR-2 specifications.
When equipped with the LR-1 PTM optics, the LNW62 can span distances of 40 km.
When equipped with the LR-2 PTM optics, the LNW62 can span distances of 80 km.
LNW76
The high-speed LNW76 meets or exceeds SONET OC-48 1310 nm
SR-1 specifications. These interfaces support span lengths up to 2 km.
LNW121B through LNW159B, and LNW221 through LNW259
These are high-speed Dense Wavelength Division Multiplexing
(DWDM) 100 GHz-spacing OLIUs that exceed SONET OC-48 1550
LR-2 specifications. The difference between the LNW121B-159B series and the LNW221- LNW259 is the size of the VT switch fabric.
The LNW121B- LNW159 series can cross-connect VTs in any 12 of 48 selected STS-1s. LNW221- LNW259 can cross-connect VTs in all 48
STS-1s.
Without passive filters, these interfaces can support span lengths up to
85 km.
The LNW121B, 123B, 131B, 133B, 135B, 137B, 143B, 145B, 147B,
149B, 157B, and 159B packs are no longer available. All other 100 series packs will still be available. The LNW221, 243, and 257 packs are no longer available. All other 200 series packs will still be available.
LNW421 through LNW459
These are low-speed Dense Wavelength Division Multiplexing
(DWDM) 100 GHz-spacing OLIUs that exceed SONET OC-48 1550
LR-2 specifications. The low-speed LNW421- LNW459 series can cross-connect VTs in any 12 of 48 selected STS-1s.
Without passive filters, these interfaces can support span lengths up to
85 km.
The LNW421, 423, 431, 433, 435, 437, 443, 445, 457 packs are no longer available. All other 400 series packs are still available.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 0 - 3 1
OC-48 OLIU (DWDMs, LNW26B, LNW27, LNW28, LNW29,
LNW31, LNW32, LNW62, LNW76, and LNW77)
Alarm thresholding
Technical Specifications
The following parameters are monitored on the OC-48 interface:
• LOS
• LOF
• AIS-L
• RFI-L (FERF)
• Line AIS
• Signal Degrade (BER)
• Signal Fail (BER).
Performance monitoring
SONET line and path performance monitoring complies with the standards outlined in GR-253-CORE. For detailed PM parameter thresholds on the OC-48 interface, Appendix B of this document.
...........................................................................................................................................................................................................................................................
1 0 - 3 2
365-372-300
Issue 8.0, September 2006
Technical Specifications
OC-192 OLIUs (LNW56, LNW57, LNW58, LNW59, LNW60,
LNW523, LNW527, LNW554, and LNW555)
............................................................................................................................................................................................................................................................
Optical specification
This section briefly details the optical specifications for the OC-192 circuit packs.
LNW59
The LNW59 provides 2 ports capable of supporting 1.3SR1, 1.5IR2, and 1.5LR2 PTM/XFPs.
The SR-1 PTMs conform to SONET OC-192 1310 nm SR-1 specifications. The IR-2 and LR-2 PTMs conform to SONET OC-192
1.5-IR2 and 1.5-LR2 specifications respectively.
When equipped with SR-1 PTM optics, the LNW59 can span distances of 2 km.
When equipped with the IR-2 PTM optics, the LNW59 can span distances of 40 km.
When equipped with the LR-2 PTM optics, the LNW59 can span distances of 80 km.
LNW56
These are high-speed, intermediate reach OLIUs that meet or exceed
SONET OC-192 1550 IR-2 specifications. The LNW56 circuit pack bridges span lengths up to 40 km. The LNW56 transmits in the general
1550 nm range.
LNW57 and LNW60
The LNW57 and LNW60 OC-192 OLIU circuit packs are high-speed, long-reach OLIUs that adhere to a modified GR-253 OC-192 LR-2 standard. The LNW57 and LNW60 transmit a single wavelength at
1533.465 nm (channel 55).
The LNW57 can support span lengths of up to 92 km. The LNW60 utilizes an on-board amplifier module to bridge spans of up to 124 km.
The LNW57 and LNW60 circuit packs utilize a “dither tone” to frequency modulate the laser. This technique is used to minimize the effects of Stimulated Brillouin Scattering (SBS).
At high optical launch powers, SBS can cause an acoustic back-scattering phenomenon in fibers. The dither tone effectively broadens the spectrum of the narrow optical pulse, thus raising the threshold power where SBS becomes an issue.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 0 - 3 3
OC-192 OLIUs
Technical Specifications
Normally, Lucent recommends that the optical output of the OC-192 circuit packs be amplified to no more than +10 dBm. However, with the dither tone circuit incorporated into the LNW57 and LNW60, optical amplification of these circuit packs to higher power levels is acceptable.
For fibers carrying multiple wavelengths in DWDM systems, it should be noted that the individual channel (individual wavelength) power determines the SBS threshold, not the total composite power of all the channels.
LNW58 (optical interface for intra-office applications)
These are high-speed, very short reach (VSR) OC-192 OLIUs that meet or exceed ITU G.693 VSR600-2R1 specifications. The LNW56 circuit pack bridges span lengths up to 600 meters. The LNW58 transmits in the general 1310 nm range.
LNW523, LNW527, and LNW554
The LNW523/527/554 circuit packs are DWDM, high-speed, long-reach OLIUs that adhere to a modified GR-253 LR-2 standard.
Without passive filters, the LNW523/527/554 can bridge span lengths up at 92 km.
The LNW523/527/554 employ tunable lasers that support 4 separate wavelengths on each of the three packs. With a simple adjustment, the
LNW523/527/554 lasers can be made to transmit different wavelengths. This feature offers obvious advantages to single frequency circuit packs in that one pack may be ordered and used to support a variety of frequency requirements. Packs can be reused in new applications requiring different wavelengths and thus the need to order new packs simply to support different wavelengths can, in some cases, be avoided.
The LNW523 is being DA’d and will no longer be available as of
6/30/07.
LNW555
The LNW555 is a DWDM, high-speed, long-reach OLIU that adheres to a modified GR-253 OC-192 LR-2 standard. The LNW555 can be used as a generic long-reach (80 km) OLIU or as a single wavelength
DWDM OLIU. When used as a generic, long-reach OLIU (without passive filters), the LNW555 circuit pack bridges span lengths up to 81 km. The LNW555 transmits a single wavelength at 1533.465 nm
(channel 55).
...........................................................................................................................................................................................................................................................
1 0 - 3 4
365-372-300
Issue 8.0, September 2006
OC-192 OLIUs
Technical Specifications
Reference
Refer to the following sections for detailed system, transmitter, receiver, and link budget specifications:
•
SONET Optical Specifications: OC-192 OLIU (LNW59)
•
SONET Optical Specifications: OC-192 OLIU (LNW57 and LNW60)
•
SONET Optical Specifications: OC-192 OLIU (LNW56 and LNW58)
•
DWDM OC-192 OLIUs (LNW523, LNW527, LNW554, and LNW555)
Alarm thresholding
The following parameters are monitored on the OC-192 interface:
• LOS
• LOF
• AIS-L
• RFI-L (FERF)
• Line AIS
• Signal Degrade (BER)
• Signal Fail (BER).
Performance monitoring
SONET line and path performance monitoring complies with the standards outlined in GR-253-CORE. For detailed PM parameter thresholds on the OC-192 interface, refer to Appendix B of this document.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 0 - 3 5
Technical Specifications
SONET Optical Specifications: OC-3 and OC-12 Low-speed OLIUs
(LNW36, LNW46)
............................................................................................................................................................................................................................................................
Overview
The following tables present the optical specifications for the OC-3
LNW36 low-speed OLIU, and the OC-12 LNW46 low-speed OLIU.
System specifications
The table below lists the LNW36 and LNW46 OLIU system specifications.
Table 10-5 SONET Optical System Specifications
System Information
Optical Line Rate
Optical Line Coding
Optical Wavelength
Performance
Temperature Range
LNW36
155.52 Mb/s
Scrambled NRZ
1310nm
SONET OC-3
LR-1 (Long Reach)
OSP Hardened
LNW46
622.08 Mb/s
Scrambled NRZ
1310 nm
SONET OC-12 LR-1
(Long Reach)
OSP Hardened
...........................................................................................................................................................................................................................................................
1 0 - 3 6
365-372-300
Issue 8.0, September 2006
SONET Optical Specifications: OC-3 and OC-12
OLIUs
Technical Specifications
Transmitter specifications
The table below lists the LNW36 and LNW46 OLIU transmitter information.
Table 10-6 SONET Optical Transmitter Information
Transmitter Information
Optical Device Temperature
Controller
FDA Classification
Optical Source
Faceplate Optical Connector
LNW36
None
Class I
Distributed Feed-Back
(DFB)/ Fabry Perot (FP)
Laser
LC connector
LNW46
None
Class I
Distributed
Feed-Back (DFB)
Laser
LC connector
Receiver specifications
The table below lists the OLIU receiver information.
Table 10-7 SONET Optical Receiver Information
Receiver Information
Optical Detector
Faceplate Optical Connector
LNW36
InGaAsP PIN
LC connector
LNW46
InGaAsP PIN
LC connector
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 0 - 3 7
SONET Optical Specifications: OC-3 and OC-12
OLIUs
Link budgets
Technical Specifications
The table below lists the LNW36 and LNW46 OLIU link budgets.
Table 10-8 SONET Optical Specifications and Link Budgets
Parameter
Minimum Wavelength
Maximum Wavelength
Maximum Spectral Width (
∆λ
20
)
Maximum RMS Spectral Width
(
σ
)
Minimum Side Mode Suppression
Ratio (SSR)
Maximum Transmitter Power
Minimum Transmitter Power
Maximum Received Power
Minimum Received Power
(@
BER of 1x10
(-12)
)
System Gain (see Note 2)
Optical Path Penalty
(see Note 3)
Additional Connector Loss
Margin (see Note 4)
Additional Unallocated Margin
(see Note 5)
Minimum Loss Budget
(see Note 6)
Maximum Loss Budget
(see Note 7)
Approximate Span Length
(see Note 8)
LNW36
OC-3 LR-1
(Note 1)
1280 nm
1335 nm
1.0 nm
NA
30 dB
0.0 dBm
-5.0 dBm
0.0 dBm
-34.0 dBm
29.0 dB
1.0 dB
1.5 dB
1.5 dB
0.0 dB
25.0 dB
55 km
LNW46
OC-12 LR-1
(Note 1)
1280 nm
1335 nm
1.0 nm
NA
30 dB
+2.0 dBm
-2.5 dBm
-7.0 dBm
-30.5 dBm
28.0 dB
1.0 dB
1.5 dB
1.5 dB
9.0 dB
24.0 dB
53 km
NOTES
1.All terminology is consistent with GR-253-CORE, Issue 3. All values are worst-case end of life.
2.The System Gain includes connector loss at the transmitter and receiver points S and R in GR-253-CORE, Issue 3.
...........................................................................................................................................................................................................................................................
1 0 - 3 8
365-372-300
Issue 8.0, September 2006
SONET Optical Specifications: OC-3 and OC-12
OLIUs
Technical Specifications
3.Optical path penalty includes effects of dispersion, reflection, and jitter that occur on the optical path. The optical path penalty for 1310 nm optics is normally 1.0 dB.
4.One additional connector (0.75 dB) on each end is assumed to connect station cable to outside plant.
5.Additional unallocated margin, or safety margin, can be 0-3 dB.
Typically, a 1.5 dB value is assumed.
6.For all packs where the Minimum Loss Budget (MLB) is 0, no attenuator is required for loopbacks. For all packs where the MLB is greater than 0, an attenuator is required. The value of the LBO shall be equal to or greater than the MLB. The MLB is found in the table above.
7.The stated maximum loss budget equals the System Gain, less the
Optical Path Penalty, the Additional Connector Loss Margin, and the
Additional Unallocated Margin. The resultant Maximum Loss Budget is available for station cable loss, transmission cable loss, and splice loss.
8.The Approximate Span Length values are calculated per an attenuation assumption. As a general rule, for attenuation-limited systems, an attenuation of 0.45 dB/km is used for 1310 nm optics.
This estimate includes typical cable loss (0.40 dB/km) and up to 11 splice losses (0.2 dB per splice). For 1310 nm OC-3 and OC-12 systems, dispersion is not a limiting factor, and the applications are attenuation-limited. Approximate span lengths can be calculated more precisely based on particular fiber and splice characteristics and local engineering rules.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 0 - 3 9
Technical Specifications
SONET Optical Specifications: OC-12 High-speed OLIUs (LNW48,
LNW50, and LNW54)
............................................................................................................................................................................................................................................................
Overview
The following tables present the optical specifications for the OC-12
LNW48, LNW50, and LNW54 high-speed OLIUs.
System specifications
The table below lists the OC-12 LNW48, LNW50, and LNW54 system specifications.
Table 10-9 SONET Optical System Specifications
System
Information
LNW48
Optical Line Rate 622.08 Mb/s
Optical Line Coding Scrambled NRZ
Optical Wavelength 1310 nm
Performance SONET OC-12 IR-1
(Intermediate Reach)
Temperature Range OSP Hardened
LNW50 LNW54
622.08 Mb/s
Scrambled NRZ
622.08 Mb/s
Scrambled NRZ
1310 nm 1550 nm
SONET OC-12
LR-1 (Long Reach)
SONET OC-12
LR-2 (Long Reach)
OSP Hardened OSP Hardened
...........................................................................................................................................................................................................................................................
1 0 - 4 0
365-372-300
Issue 8.0, September 2006
SONET Optical Specifications: OC-12 High-speed OLIUs (LNW48,
LNW50, and LNW54)
Technical Specifications
Transmitter specifications
The table below lists the OC-12 LNW48, LNW50, and LNW54 transmitter information.
Table 10-10 SONET Optical Transmitter Information
Transmitter Info.
Optical Device
Temperature
Controller
FDA Classification
Optical Source
Faceplate Optical
Connector
LNW48
None
Class I
Fabry Perot
(FP) Laser
LC connector
LNW50
None
Class I
Distributed
Feed-Back
(DFB) Laser
LC connector
LNW54
None
Class I
Distributed
Feed-Back
(DFB) Laser
LC connector
Receiver specifications
The table below lists the OC-12 LNW48, LNW50, and LNW54 receiver information.
Table 10-11 SONET Optical Receiver Information
Receiver
Information
Optical Detector
Faceplate Optical
Connector
LNW48
InGaAsP PIN
LC connector
LNW50
InGaAsP PIN
LC connector
LNW54
InGaAsP PIN
LC connector
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 0 - 4 1
SONET Optical Specifications: OC-12 High-speed OLIUs (LNW48,
LNW50, and LNW54)
Technical Specifications
Link budgets
The table below lists the OC-12 LNW48, LNW50, and LNW54 link budgets.
Table 10-12 SONET Optical Specifications and Link Budgets
Parameter
Minimum Wavelength
Maximum Wavelength
LNW48
OC-12 IR-1
(Note 1)
1274 nm
(1293 nm)
1356 nm
(1334 nm)
Maximum Spectral Width
(
∆λ
20
)
Maximum RMS Spectral
Width (
σ
)
Minimum Side Mode
Suppression Ratio (SSR)
NA
2.5 nm
(4.0 nm)
NA
Maximum Transmitter Power -8.0 dBm
Minimum Transmitter Power -15.0 dBm
-8.0 dBm Maximum Received Power
Minimum Received Power
(@
BER of 1x10
(-12)
)
-28.0 dBm
13.0 dB System Gain (see Note 2)
Optical Path Penalty
(see Note 3)
Additional Connector Loss
Margin (see Note 4)
Additional Unallocated
Margin (see Note 5)
Minimum Loss Budget
(see Note 6)
Maximum Loss Budget
(see Note 7)
Approximate Span Length
(see Note 8)
1.0 dB
1.5 dB
1.5 dB
0.0 dB
9.0 dB
20 km
LNW50
OC-12 LR-1
(Note 1)
LNW54
OC-12 LR-2
(Note 1)
1280 nm
1335 nm
1.0 nm
NA
30 dB
+2.0 dBm
-2.5 dBm
-7.0 dBm
-30.5 dBm
28.0 dB
1.0 dB
1.5 dB
1.5 dB
9.0 dB
24.0 dB
53 km
1480 nm
1580 nm
1.0 nm
NA
30 dB
+2.0 dBm
-3.0 dBm
-8.0 dBm
-29.0 dBm
26.0 dB
1.0 dB
1.5 dB
1.5 dB
10.0 dB
22.0 dB
81 km
...........................................................................................................................................................................................................................................................
1 0 - 4 2
365-372-300
Issue 8.0, September 2006
SONET Optical Specifications: OC-12 High-speed OLIUs (LNW48,
LNW50, and LNW54)
Technical Specifications
NOTES
1.All terminology is consistent with GR-253-CORE, Issue 3. All values are worst-case end of life.
2.The System Gain includes connector loss at the transmitter and receiver points S and R in GR-253-CORE, Issue 3.
3.Optical path penalty includes effects of dispersion, reflection, and jitter that occur on the optical path. At OC-12 rates, the optical path penalty is normally 1.0 dB for both 1310 nm and 1550 nm optics.
4.One additional connector (0.75 dB) on each end is assumed to connect station cable to outside plant.
5.Additional unallocated margin, or safety margin, can be 0-3 dB.
Typically, a 1.5 dB value is assumed.
6. For all packs where the Minimum Loss Budget (MLB) is 0, no attenuator is required for loopbacks. For all packs where the MLB is greater than 0, an attenuator is required. The value of the LBO shall be equal to or greater than the MLB. The MLB is found in the table above.
7.The stated maximum loss budget equals the System Gain, less the
Optical Path Penalty, the Additional Connector Loss Margin, and the
Additional Unallocated Margin. The resultant Maximum Loss Budget is available for station cable loss, transmission cable loss, and splice loss.
8.The Approximate Span Length values are calculated per an attenuation assumption. As a general rule, for attenuation-limited systems, an attenuation of 0.45 dB/km is used for 1310 nm optics.
This estimate includes typical cable loss (0.40 dB/km) and up to 11 splice losses (0.2 dB per splice). For 1550 nm optics, an attenuation of 0.27 dB/km is used. Again, appropriate fiber-cable loss and numerous splice losses are included. For 1310 nm OC-3 and OC-12 systems, dispersion is not a limiting factor, and the applications are attenuation-limited. Approximate span lengths can be calculated more precisely based on particular fiber and splice characteristics and local engineering rules.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 0 - 4 3
Technical Specifications
SONET Optical Specifications: OC-3 OLIUs (LNW37 and LNW45) with PTM pluggable optics
............................................................................................................................................................................................................................................................
Overview
The following tables present the optical specifications for the OC-3
LNW37 and LNW45 OLIUs.
System specifications
DMX utilizes Pluggable Transmission Module (PTM) optics on the
LNW37 and LNW45 circuit packs. To ensure proper optical performance, mechanical fit, compliance with EMC, and compliance with laser safety standards, the Lucent specified PTM transceivers must be used.
Only the Lucent specified PTM transceivers are compatible with DMX software. If non-Lucent specified PTM transceivers are installed in
DMX, the system will reject that transceiver, and that optical port will become inoperable (until approved parts are installed).
Refer to Chapter 7 or
Allowed Optics
for specific ordering information concerning these transceivers.
Laser Safety CAUTION!
Use only the Lucent specified Class 1 transceivers.
The table below lists the LNW37 and LNW45 OLIU system specifications.
Table 10-13 SONET Optical System Specifications
System Information
Optical Line Rate
Optical Line Coding
Optical Wavelength
Performance
Temperature Range
LNW37/45
155.52 Mb/s
Scrambled NRZ
1310 nm
PTM Optics for SONET OC-3 SR-1 (Short Reach),
IR-1 (Intermediate Reach), and LR-1 (Long Reach)
OSP
...........................................................................................................................................................................................................................................................
1 0 - 4 4
365-372-300
Issue 8.0, September 2006
SONET Optical Specifications: OC-3 OLIUs (LNW37 and LNW45) with PTM pluggable optics
Technical Specifications
Transmitter specifications
The table below lists the LNW37/45 OLIU transmitter information.
Table 10-14 SONET Optical Transmitter Information
Transmitter Info.
Optical Device Temperature
Controller
FDA Classification
Optical Source
(FP for SR and IR, LED for SR only, FP or DFB for LR)
Faceplate Optical Connector
LNW37/45
None
Class I
Distributed Feed-Back (DFB)/
Fabry Perot (FP)/ Light Emitting
Diode (LED)
Laser
LC connector
Receiver specifications
The table below lists the OLIU receiver information.
Table 10-15 SONET Optical Receiver Information
Receiver Information
Optical Detector
Faceplate Optical Connector
LNW37/45
InGaAsP PIN
LC connector
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 0 - 4 5
SONET Optical Specifications: OC-3 OLIUs (LNW37 and LNW45) with PTM pluggable optics
Technical Specifications
Link budgets
The table below lists the LNW37/45 OLIU link budgets.
Table 10-16 SONET Optical Specifications and Link Budgets
Parameter
Minimum Wavelength
Maximum Wavelength
Maximum Spectral Width (
∆λ
20
)
Maximum RMS Spectral Width (
σ
)
Minimum Side-Mode Suppression
Ratio (SSMR)
Maximum Transmitter Power
Minimum Transmitter Power
Maximum Received Power
Minimum Received Power
(@
BER of 1x10
(-10)
)
System Gain (see Note 2)
Optical Path Penalty
(see Note 3)
Additional Connector Loss margin
(see Note 4)
Additional Unallocated Margin
(see Note 5)
Minimum Loss Budget
(see Note 6)
Maximum Loss Budget
(see Note 7)
Approximate Span Length
(see Note 8)
LNW37/45
OC-3 SR-1
(Note 1)
LNW37/45
OC-3 IR-1
(Note 1)
FP /LED Laser FP Laser
1260 nm
1360 nm
NA
40/80 nm
1261 nm
1360 nm
NA
7.7 nm
NA
-8.0 dBm
-15.0 dBm
-8.0 dBm
-23.0 dBm
8.0 dB
1.0 dB
1.5 dB
1.5 dB
0 dB
4.0 dB
2 km
NA
-8.0 dBm
-15.0 dBm
-8.0 dBm
-28.0 dBm
13.0 dB
1.0 dB
1.5 dB
1.5 dB
0 dB
9.0 dB
20 km
LNW37/45
OC-3 LR-1
(Note 1)
FP / (DFB) Laser
1263 nm
1360 nm
NA / (1.0 nm)
3.0 nm / (NA)
NA / (30 dB)
0.0 dBm
-5.0 dBm
-10.0 dBm
-34.0 dBm
29.0 dB
1.0 dB
1.5 dB
1.5 dB
10.0 dB
25.0 dB
55 km
NOTES
1. All terminology is consistent with GR-253-CORE, Issue 3. All values are worst-case end of life. Optical specifications meet or exceed
...........................................................................................................................................................................................................................................................
1 0 - 4 6
365-372-300
Issue 8.0, September 2006
SONET Optical Specifications: OC-3 OLIUs (LNW37 and LNW45) with PTM pluggable optics
Technical Specifications
equivalent GR-253-CORE requirements.
2. The System Gain includes connector loss at the transmitter and receiver points S and R in GR-253-CORE, Issue 3.
3. Optical path penalty includes effects of dispersion, reflection, and jitter that occur on the optical path. The optical path penalty for 1310 nm optics is normally 1.0 dB.
4. One additional connector (0.75 dB) on each end is assumed to connect station cable to outside plant.
5. Additional unallocated margin, or safety margin, can be 0-3 dB.
Typically, a 1.5 dB value is assumed.
6. For all packs where the Minimum Loss Budget (MLB) is 0, no attenuator is required for loopbacks. For all packs where the MLB is greater than 0, an attenuator is required. The value of the LBO shall be equal to or greater than the MLB. The MLB is found in the table above.
7. The stated maximum loss budget equals the System Gain, less the
Optical Path Penalty. The resultant Maximum Loss Budget is available for station cable loss, transmission cable loss, and splice loss.
8. The Approximate Span Length values are calculated per an attenuation assumption. As a general rule, for attenuation-limited systems, an attenuation of 0.45 dB/km is used for 1310 nm optics. This estimate includes typical cable loss (0.40 dB/km) and up to 11 splice losses (0.2 dB per splice). For 1310 nm OC-3 and OC-12 systems, dispersion is not a limiting factor, and the applications are attenuation-limited. Approximate span lengths can be calculated more precisely based on particular fiber and splice characteristics and local engineering rules.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 0 - 4 7
Technical Specifications
SONET Optical Specifications: OC-12 OLIUs (LNW49) with PTM pluggable optics
............................................................................................................................................................................................................................................................
Overview
The following tables present the optical specifications for the LNW49
OC-12 OLIU.
DMX utilizes Pluggable Transmission Module (PTM) optics on the
LNW49 circuit packs. To ensure proper optical performance, mechanical fit, compliance with EMC, and compliance with laser safety standards, the Lucent specified PTM transceivers must be used.
Only the Lucent specified PTM transceivers are compatible with DMX software. If non-Lucent specified PTM transceivers are installed in
DMX, the system will reject that transceiver, and that optical port will become inoperable (until approved parts are installed).
Refer to Chapter 7 or
Allowed Optics
(LNW49) for specific ordering information concerning these transceivers.
Laser Safety CAUTION!
Use only the Lucent specified Class 1 transceivers.
System specifications
The table below lists the LNW49 OLIU system specifications.
Table 10-17 SONET Optical System Specifications
System Information LNW49
Optical Line Rate
Optical Line Coding
622.08 Mb/s
Scrambled NRZ
Optical Wavelength
Performance
Temperature Range
1310 nm (1550 nm for LR-2)
PTM Optics for SONET OC-12
IR-1 (Intermediate Reach),
LR-1 (Long Reach), and
LR-2 (Very Long Reach)
OSP
...........................................................................................................................................................................................................................................................
1 0 - 4 8
365-372-300
Issue 8.0, September 2006
SONET Optical Specifications: OC-12 OLIUs (LNW49) with PTM pluggable optics
Technical Specifications
Transmitter specifications
The table below lists the LNW49 OLIU transmitter information.
Table 10-18 SONET Optical Transmitter Information
Transmitter Info.
Optical Device Temperature
Controller
FDA Classification
Optical Source
(FP for SR and IR, FP or DFB for
LR)
Faceplate Optical Connector
LNW49
None
Class I
Distributed Feed-Back (DFB)/
Fabry Perot (FP)
Laser
LC connector
Receiver specifications
The table below lists the OLIU receiver information.
Table 10-19 SONET Optical Receiver Information
Receiver Information
Optical Detector
Faceplate Optical Connector
LNW49
InGaAsP PIN
LC connector
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 0 - 4 9
SONET Optical Specifications: OC-12 OLIUs (LNW49) with PTM pluggable optics
Link budgets
The table below lists the LNW49 OLIU link budgets.
Technical Specifications
Table 10-20 SONET Optical Specifications and Link Budgets
Parameter
Minimum Wavelength
Maximum Wavelength
Maximum Spectral Width (
∆λ
20
)
Maximum RMS Spectral Width (
σ
)
Minimum Side-Mode Suppression
Ratio (SSMR)
Maximum Transmitter Power
Minimum Transmitter Power
Maximum Received Power
Minimum Received Power
(@
BER of 1x10
(-10)
)
System Gain (see Note 2)
Maximum Dispersion
Optical Path Penalty
(see Note 3)
Minimum Loss Budget
(see Note 5)
Maximum Loss Budget
(see Note 6)
Approximate Span Length
(see Note 7)
LNW49
OC-12 IR-1
(Note 1)
FP Laser
1274 nm
1356 nm
NA
2.5 nm
NA
-8.0 dBm
-15.0 dBm
-8.0 dBm
-28.0 dBm
13.0 dB
NA
1.0 dB
0 dB
12.0 dB
15 km
LNW49
OC-12 LR-1
(Note 1)
DFB Laser
1280 nm
1335 nm
1.0 nm
NA
30 dB
+2.0 dBm
-3.0 dBm
-8.0 dBm
-28.0 dBm
25.0 dB
NA
1.0 dB
10.0 dB
24.0 dB
40 km
LNW49
OC-12 LR-2
(Note 1)
DFB Laser
1480 nm
1580 nm
1.0 nm
NA
30 dB
+2.0 dBm
-3.0 dBm
-8.0 dBm
-28.0 dBm
25.0 dB
1600 ps/nm
1.5 dB
10.0 dB
21.0 dB
80 km
NOTES
1. All terminology is consistent with GR-253-CORE, Issue 3. All values are worst-case end of life. Optical specifications meet or exceed equivalent GR-253-CORE requirements.
2. The System Gain includes connector loss at the transmitter and receiver points S and R in GR-253-CORE, Issue 3.
3. Optical path penalty includes effects of dispersion, reflection, and jitter that occur on the optical path. The optical path penalty for 1310
...........................................................................................................................................................................................................................................................
1 0 - 5 0
365-372-300
Issue 8.0, September 2006
SONET Optical Specifications: OC-12 OLIUs (LNW49) with PTM pluggable optics
Technical Specifications
nm optics is normally 1.0 dB.
4. One additional connector (0.75 dB) on each end is assumed to connect station cable to outside plant.
5. For all packs where the Minimum Loss Budget (MLB) is 0, no attenuator is required for loopbacks. For all packs where the MLB is greater than 0, an attenuator is required. The value of the LBO shall be equal to or greater than the MLB. The MLB is found in the table above.
6. The stated maximum loss budget equals the System Gain, less the
Optical Path Penalty. The resultant Maximum Loss Budget is available for station cable loss, transmission cable loss, and splice loss.
7. The Approximate Span Length values are calculated per an attenuation assumption. As a general rule, for attenuation-limited systems, an attenuation of 0.45 dB/km is used for 1310 nm optics. This estimate includes typical cable loss (0.40 dB/km) and up to 11 splice losses (0.2 dB per splice). For 1310 nm OC-3 and OC-12 systems, dispersion is not a limiting factor, and the applications are attenuation-limited. Approximate span lengths can be calculated more precisely based on particular fiber and splice characteristics and local engineering rules.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 0 - 5 1
Technical Specifications
SONET Optical Specifications: OC-48 OLIUs (LNW26B, LNW27,
LNW28, LNW29, LNW32)
............................................................................................................................................................................................................................................................
Overview
The following tables present the optical specifications for the OC-48
OLIUs.
System specifications
The table below lists the OC-48 OLIU system specifications.
Table 10-21 SONET Optical System Specifications
System Information LNW26B
Optical Line Rate
Optical Line Coding
Optical Wavelength
Performance
Temperature Range Central Office
(CO)
LNW27
1310 nm
SONET LR-1 (Long Reach)
CO
LNW28
OSP Hardened
LNW29
2.488 Gb/s
Scrambled NRZ
1550 nm
SONET LR-2
(Long Reach)
CO
LNW32
1310 nm
SONET LR-1
(Long Reach)
OSP Hardened
Transmitter specifications
The table below lists the OC-48 OLIU transmitter information.
Table 10-22 SONET Optical Transmitter Information
Transmitter Info.
Optical Device
Temperature Controller
FDA Classification
Optical Source
Faceplate Optical
Connector
LNW26B LNW27 LNW28
None
LNW29
Class I
Distributed Feed-Back (DFB) Laser
LC connector
LNW32
...........................................................................................................................................................................................................................................................
1 0 - 5 2
365-372-300
Issue 8.0, September 2006
SONET Optical Specifications: OC-48 OLIUs
(LNW26B, LNW27, LNW28, LNW29, LNW32)
Technical Specifications
Receiver Specifications
The table below lists the OC-48 OLIU receiver information.
Table 10-23 SONET Optical Receiver Information
Receiver Information
Optical Detector
Faceplate Optical Connector
LNW26B LNW27 LNW28 LNW29 LNW32
APD
LC connector
Link budgets
The table below lists the OC-48 OLIU link budgets.
Table 10-24 SONET Optical Specifications and Link Budgets
Parameter (NOTE 1)
Minimum Wavelength
Maximum Wavelength
Maximum Spectral Width (
∆λ
20
)
Maximum Transmitter Power
Minimum Transmitter Power
Maximum Received Power
(1x10
-12
BER)
Minimum Received Power
(1x10
-12
BER)
Minimum System Gain (see Note 2)
LNW26B
OC-48
LR-1
1280 nm
1335 nm
1.0 nm
1335 nm
1.0 nm
+3.0 dBm +3.0 dBm +3.0 dBm +3.0 dBm +3.0 dBm
-2.0 dBm
-8.0 dBm
LNW27
OC-48
LR-1
1280 nm
1335 nm
1.0 nm
-2.0 dBm
-8.0 dBm
LNW28
OC-48
LR-1
1280 nm
1335 nm
1.0 nm
-2.0 dBm
-8.0 dBm
LNW29
OC-48
LR-2
1500 nm
1580 nm
1.0 nm
-2.0 dBm
-8.0 dBm
LNW32
OC-48
LR-1
1280 nm
-2.0 dBm
-8.0 dBm
Dispersion
-29.0 dBm -29.0 dBm -29.0/-28.0 dBm*
27.0 dB 27.0 dB
NA NA
27.0/26.0
dB*
NA
1.0 dB 1.0 dB 1.0 dB
-29.0 dBm -29.0/-28.0 dBm*
27.0 dB
1600 ps/nm
27.0/26.0
dB*
NA
2.0 dB 1.0 dB
1.5 dB 1.5 dB 1.5 dB 1.5 dB 1.5 dB
Optical Path Penalty (see Note 3)
Additional Connector Loss Margin
(see Note 4)
Additional Unallocated Margin
(see Note 5)
Minimum Loss Budget (see Note 6)
Maximum Loss Budget (see Note 7)
1.5 dB
11.0 dB
23.0 dB
1.5 dB
11.0 dB
23.0 dB
1.5 dB
11.0 dB
23.0/22.0* dB
1.5 dB
11.0 dB
22.0 dB
1.5 dB
11.0 dB
23.0/22.0* dB
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 0 - 5 3
SONET Optical Specifications: OC-48 OLIUs
(LNW26B, LNW27, LNW28, LNW29, LNW32)
Technical Specifications
Parameter (NOTE 1) LNW26B
OC-48
LR-1
LNW27
OC-48
LR-1
LNW28
OC-48
LR-1
LNW29
OC-48
LR-2
Approximate Span Length (see Note 8) 51 km 51 km 51/49 km* 81 km
*The LNW28 and LNW32 are environmentally hardened OLIUs (it is capable of operating in outside plant temperature ranges). The first number applies to deployments in standard CO applications; the second number applies to deployments where temperature excursions (found in OSP environments) may occur.
LNW32
OC-48
LR-1
51/49 km*
Notes
1. All terminology is consistent with GR-253-CORE, Issue 3. All values are worst-case end of life (EOL). Optical specifications meet or exceed equivalent GR-253-CORE requirements.
2. The System Gain includes connector loss at the transmitter and receiver points S and R in GR-253-CORE, Issue 3.
3. Optical path penalty includes effects of dispersion, reflection, and jitter that occur on the optical path. The optical path penalty for 1310 nm optics is 1.0 dB maximum. The optical path penalty for the 1550 nm optics is 2.0 maximum.
4. One additional connector (0.75 dB) on each end is assumed to connect station cable to outside plant.
5. Additional unallocated margin, or safety margin, can be 0-3 dB.
Typically, a 1.5 dB value is assumed.
6. For all packs where the Minimum Loss Budget (MLB) is 0, no attenuator is required for loopbacks. For all packs where the MLB is greater than 0, an attenuator is required. The value of the LBO shall be equal to or greater than the MLB. The MLB is found in the table above.
7. The stated maximum loss budget equals the System Gain, less the
Optical Path Penalty, the Additional Connector Loss Margin, and the
Additional Unallocated Margin. The resultant Maximum Loss
Budget is available for station cable loss, transmission cable loss, and splice loss.
8. The approximate Approximate Span Length values are calculated per an attenuation assumption. As a general rule, for attenuation-limited systems, an attenuation of 0.45 dB/km is used for 1310 nm optics.
This estimate includes typical cable loss (0.40 dB/km) and up to 11 splice losses (0.2 dB per splice). For 1310 nm OC-48 systems, dispersion is not a limiting factor, and the applications are attenuation-limited. For 1550 nm optics, an attenuation of 0.27
dB/km is used. Again, appropriate fiber-cable loss and numerous splice losses are included. For long-reach 1550nm applications, dispersion may be a limiting factor. Approximate Span Lengths can
...........................................................................................................................................................................................................................................................
1 0 - 5 4
365-372-300
Issue 8.0, September 2006
SONET Optical Specifications: OC-48 OLIUs
(LNW26B, LNW27, LNW28, LNW29, LNW32)
Technical Specifications
be calculated more precisely based on particular fiber and splice characteristics and local engineering rules.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 0 - 5 5
Technical Specifications
SONET Optical Specifications: OC-48 OLIU (LNW62)
............................................................................................................................................................................................................................................................
Overview
The following tables present the optical specifications for the LNW62
OC-48 PTMs.
Allowed Optics
The table below lists the PTM optics, also known as SFP optics, that may be used in the LNW62 circuit pack.
To ensure proper optical performance, mechanical fit, compliance with
EMC, and compliance with laser safety standards, the Lucent specified
PTM transceivers listed in the table below must be used.
Only the Lucent specified PTM transceivers listed below are compatible with DMX software. If non-Lucent specified PTM transceivers are installed in DMX, the system will reject that transceiver, and that optical port will become inoperable (until approved parts are installed).
Table 10-25 PTM Optics for LNW62
Apparatus Code
OC48LR1-I1
OC48LR2-I1
Comcode
109493528
109504431
Description
OC48 PTM TRCVR
Long Reach, 1.3 LR-1 (40km),
1310nm
OC48 PTM TRCVR
Long Reach, 1.5 LR-2 (80km),
1550nm
...........................................................................................................................................................................................................................................................
1 0 - 5 6
365-372-300
Issue 8.0, September 2006
SONET Optical Specifications: OC-48 OLIU
(LNW62)
Technical Specifications
System specifications
The following table lists the LNW62 PTM system specifications.
Table 10-26 SONET Optical System Specifications
System Information
Optical Line Rate
Optical Line Coding
Optical Wavelength
Performance
Temperature Range
LNW62
2.488 Gb/s
Scrambled NRZ
1310 nm
SONET LR-1 (Long
Reach)
OSP hardened
2.488 Gb/s
Scrambled NRZ
1550 nm
SONET LR-2 (Long
Reach)
OSP hardened
Transmitter specifications
The following table lists the LNW62 PTM OLIU transmitter information.
Table 10-27 SONET Optical Transmitter Information
Transmitter Info.
LNW62
Optical Device Temperature
Controller
FDA Classification
Optical Source
Faceplate Optical Connector
SONET LR-1
None
Class I
Distributed Feed-Back
(DFB) Laser
LC connector
SONET LR-2
None
Class I
Distributed Feed-Back
(DFB) Laser
LC connector
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 0 - 5 7
SONET Optical Specifications: OC-48 OLIU
(LNW62)
Technical Specifications
Receiver specifications
The following table lists the LNW62 PTM receiver information.
Table 10-28 SONET Optical Receiver Information
Receiver Information
Optical Detector
Faceplate Optical Connector
SONET LR-1
InGaAsP PIN
LC connector
LNW62
SONET LR-2
APD
LC connector
...........................................................................................................................................................................................................................................................
1 0 - 5 8
365-372-300
Issue 8.0, September 2006
SONET Optical Specifications: OC-48 OLIU
(LNW62)
Technical Specifications
Link budgets
The following table lists the LNW62 PTM link budgets. Text inserts in parenthesis under the PTM name in each column denote the apparatus codes for the equivalent unified PTMs also available in R7.0.
Table 10-29 SONET Optical Specifications and Link Budgets
Parameter
Minimum Wavelength
Maximum Wavelength
Maximum Spectral Width (
∆λ
20
)
Maximum RMS Spectral Width (
σ
)
Maximum Transmitter Power
Minimum Transmitter Power
Maximum Received Power
(1x10
-10
BER)
Minimum Received Power
(1x10
-10
BER)
Maximum Dispersion
Minimum System Gain
(see Note 2)
Optical Path Penalty
(see Note 3)
Additional Connector Loss margin
(see Note 4)
Additional Unallocated Margin
(see Note 5)
Minimum Loss Budget
Maximum Loss Budget
(see Note 6)
Approximate Span Length
(see Note 7)
LNW62
OC-48 LR-1
1280 nm
1335 nm
1.0 nm
NA
3.0 dBm
-2.0 dBm
-9.0 dBm
-27.0 dBm
NA
25.0 dB
1.0 dB
1.5 dB
1.5 dB
12.0 dB
21.0 dB
46 km
LNW62
OC-48 LR-2
1500 nm
1580 nm
1.0 nm
NA
3.0 dBm
-2.0 dBm
-9.0 dBm
-28.0 dB
1600 ps/nm
26.0 dB
2.0 dB
1.5 dB
1.5 dB
12.0 dB
21.0 dB
78 km
NOTES
1. All terminology is consistent with GR-253-CORE, Issue 3. All values are worst-case end of life (EOL). Optical specifications meet or
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 0 - 5 9
SONET Optical Specifications: OC-48 OLIU
(LNW62)
Technical Specifications
exceed equivalent GR-253-CORE requirements.
2. The System Gain includes connector loss at the transmitter and receiver points S and R in GR-253-CORE, Issue 3.
3. Optical path penalty includes effects of dispersion, reflection, and jitter that occur on the optical path. The optical path penalty for 1310 nm optics is normally 1.0 dB.
4. One additional connector (0.75 dB) on each end is assumed to connect station cable to outside plant.
5. Additional unallocated margin, or safety margin, can be 0-3 dB.
Typically, a 1.5 dB value is assumed.
6. For all packs where the Minimum Loss Budget (MLB) is 0, no attenuator is required for loopbacks. For all packs where the MLB is greater than 0, an attenuator is required. The value of the LBO shall be equal to or greater than the MLB. The MLB is found in the table above.
7. The Approximate Span Length values are calculated per an attenuation assumption. As a general rule, for attenuation-limited systems, an attenuation of 0.45 dB/km is used for 1310 nm optics.
This estimate includes typical cable loss (0.40 dB/km) and up to 11 splice losses (0.2 dB per splice). For 1310 nm OC-48 systems, dispersion is not a limiting factor, and the applications are attenuation-limited. Approximate Span Lengths can be calculated more precisely based on particular fiber and splice characteristics and local engineering rules. However, the short-reach MLM
(Multi-Longitudinal Mode— also known as Fabry Perot [FP]) laser is only recommended for spans of up to 2 km.
...........................................................................................................................................................................................................................................................
1 0 - 6 0
365-372-300
Issue 8.0, September 2006
Technical Specifications
SONET Optical Specifications: OC-48 OLIU (LNW76 and LNW77)
............................................................................................................................................................................................................................................................
Overview
The following tables present the optical specifications for the LNW76 and LNW77 OC-48 OLIUs.
System specifications
The following table lists the LNW76 and LNW77 OC-48 OLIU system specifications.
Table 10-30 SONET Optical System Specifications
System Information
Optical Line Rate
Optical Line Coding
Optical Wavelength
Performance
Temperature Range
LNW76
2.488 Gb/s
Scrambled NRZ
1310 nm
SONET SR-1 (Short Reach)
Central Office (CO)
LNW77
2.488 Gb/s
Scrambled NRZ
1310 nm
SONET IR-1 (Intermediate Reach)
Central Office (CO)
Transmitter specifications
The following table lists the LNW76 and LNW77 OC-48 OLIU transmitter information.
Table 10-31 SONET Optical Transmitter Information
Transmitter Info.
Optical Device Temperature
Controller
FDA Classification
Optical Source
Faceplate Optical Connector
LNW76
None
Class I
Fabry-Perot (FP) Laser
LC connector
LNW77
None
Class I
Distributed Feed-Back (DFB) Laser
LC connector
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 0 - 6 1
SONET Optical Specifications: OC-48 OLIU
(LNW76 and LNW77)
Technical Specifications
Receiver specifications
The following table lists the LNW76 and LNW77 OC-48 OLIU receiver information.
Table 10-32 SONET Optical Receiver Information
Receiver Information
Optical Detector
Faceplate Optical Connector
LNW76
InGaAsP PIN
LC connector
LNW77
InGaAsP PIN
LC connector
...........................................................................................................................................................................................................................................................
1 0 - 6 2
365-372-300
Issue 8.0, September 2006
SONET Optical Specifications: OC-48 OLIU
(LNW76 and LNW77)
Technical Specifications
Parameter
Link budgets
The following table lists the LNW76 and LNW77 OC-48 OLIU link budgets.
Table 10-33 SONET Optical Specifications and Link Budgets
Minimum Wavelength
Maximum Wavelength
Maximum Spectral Width (
∆λ
20
)
Maximum RMS Spectral Width (
σ
)
Maximum Transmitter Power
Minimum Transmitter Power
Maximum Received Power
(1x10
-12
BER)
Minimum Received Power
(1x10
-12
BER)
Minimum System Gain
(see Note 2)
Optical Path Penalty
(see Note 3)
Additional Connector Loss Margin
(see Note 4)
Additional Unallocated Margin
(see Note 5)
Minimum Loss Budget
Maximum Loss Budget
(see Note 6)
Approximate Span Length
(see Note 7)
LNW76
OC-48 SR-1
1266 nm
1360 nm
NA
4.0 nm
-3 dBm
-10 dBm
-3 dBm
-18 dBm
8 dB
1.0 dB
1.5 dB
1.5 dB
0.0 dB
4.0 dB
2 km
LNW77
OC-48 IR-1
1280 nm
1335 nm
1.0 nm
NA
0.0 dBm
-5.0 dBm
0.0 dBm
-18.0 dBm
13.0 dB
1.0 dB
1.5 dB
1.5 dB
0.0 dB
9.0 dB
20 km
NOTES
1. All terminology is consistent with GR-253-CORE, Issue 3. All values are worst-case end of life (EOL). Optical specifications meet or exceed equivalent GR-253-CORE requirements.
2. The System Gain includes connector loss at the transmitter and receiver points S and R in GR-253-CORE, Issue 3.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 0 - 6 3
SONET Optical Specifications: OC-48 OLIU
(LNW76 and LNW77)
Technical Specifications
3. Optical path penalty includes effects of dispersion, reflection, and jitter that occur on the optical path. The optical path penalty for 1310 nm optics is normally 1.0 dB.
4. One additional connector (0.75 dB) on each end is assumed to connect station cable to outside plant.
5. Additional unallocated margin, or safety margin, can be 0-3 dB.
Typically, a 1.5 dB value is assumed.
6. For all packs where the Minimum Loss Budget (MLB) is 0, no attenuator is required for loopbacks. For all packs where the MLB is greater than 0, an attenuator is required. The value of the LBO shall be equal to or greater than the MLB. The MLB is found in the table above.
7. The Approximate Span Length values are calculated per an attenuation assumption. As a general rule, for attenuation-limited systems, an attenuation of 0.45 dB/km is used for 1310 nm optics.
This estimate includes typical cable loss (0.40 dB/km) and up to 11 splice losses (0.2 dB per splice). For 1310 nm OC-48 systems, dispersion is not a limiting factor, and the applications are attenuation-limited. Approximate Span Lengths can be calculated more precisely based on particular fiber and splice characteristics and local engineering rules. However, the short-reach MLM
(Multi-Longitudinal Mode— also known as Fabry Perot [FP]) laser is only recommended for spans of up to 2 km.
...........................................................................................................................................................................................................................................................
1 0 - 6 4
365-372-300
Issue 8.0, September 2006
Technical Specifications
SONET Optical Specifications: OC-48 Low-Speed OLIU (LNW31)
............................................................................................................................................................................................................................................................
Overview
The following tables present the optical specifications for the low-speed (tributary interface) OC-48 OLIUs.
System specifications
The table below lists the low-speed OC-48 OLIU system specifications.
Table 10-34 SONET Optical System Specifications
System Information
Optical Line Rate
Optical Line Coding
Optical Wavelength
Performance
Temperature Range
LNW31
2.488 Gb/s
Scrambled NRZ
1310 nm
SONET IR-1 (Intermediate Reach)
CO
Transmitter specifications
The table below lists the low-speed OC-48 OLIU transmitter information.
Table 10-35 SONET Optical Transmitter Information
Transmitter Info.
Optical Device
Temperature Controller
FDA Classification
Optical Source
Faceplate Optical
Connector
LNW31
None
Class I
Distributed Feed-Back (DFB) Laser
LC connector
Reciever Specifications
The table below lists the low-speed OC-48 OLIU receiver information.
Table 10-36 SONET Optical Receiver Information
Receiver Information
Optical Detector
LNW31
PIN
Faceplate Optical Connector LC connector
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 0 - 6 5
SONET Optical Specifications: OC-48
Low-Speed OLIU (LNW31)
Technical Specifications
Link budgets
The table below lists the low-speed OC-48 OLIU link budgets.
Table 10-37 Optical Specifications and Link Budgets
Parameter (NOTE 1)
Minimum Wavelength
Maximum Wavelength
Maximum Spectral Width (
∆λ
20
)
Maximum Transmitter Power
Minimum Transmitter Power
Maximum Received Power
(1x10
-12
BER)
Minimum Received Power
(1x10
-12
BER)
Minimum System Gain (see Note 2)
Dispersion
Optical Path Penalty (see Note 3)
Additional Connector Loss Margin
(see Note 4)
Additional Unallocated Margin
(see Note 5)
Minimum Loss Budget (see Note 6)
Maximum Loss Budget (see Note 7)
Approximate Span Length (see Note 8)
LNW31
OC-48 IR-1
1260 nm
1360 nm
1.0 nm
0.0 dBm
-5.0 dBm
0.0 dBm
-18.0 dBm
13.0 dB
NA
1.0 dB
1.5 dB
1.5 dB
0.0 dB
9.0 dB
20 km
Notes
1. All terminology is consistent with GR-253-CORE, Issue 3. All values are worst-case end of life (EOL). Optical specifications meet or exceed equivalent GR-253-CORE requirements.
2. The System Gain includes connector loss at the transmitter and receiver points S and R in GR-253-CORE, Issue 3.
3. Optical path penalty includes effects of dispersion, reflection, and jitter that occur on the optical path. The optical path penalty for 1310 nm optics is 1.0 dB maximum. The optical path penalty for the 1550 nm optics is 2.0 dB maximum.
4. One additional connector (0.75 dB) on each end is assumed to connect
...........................................................................................................................................................................................................................................................
1 0 - 6 6
365-372-300
Issue 8.0, September 2006
SONET Optical Specifications: OC-48
Low-Speed OLIU (LNW31)
Technical Specifications
station cable to outside plant.
5. Additional unallocated margin, or safety margin, can be 0-3 dB.
Typically, a 1.5 dB value is assumed.
6. The LNW31 does not require an external lightguide build-out (optical attenuator) as part of the connector assembly for optical loopbacks.
7. The stated maximum loss budget equals the System Gain, less the
Optical Path Penalty, the Additional Connector Loss Margin, and the
Additional Unallocated Margin. The resultant Maximum Loss
Budget is available for station cable loss, transmission cable loss, and splice loss.
8. The approximate Approximate Span Length values are calculated per an attenuation assumption. As a general rule, for attenuation-limited systems, an attenuation of 0.45 dB/km is used for 1310 nm optics.
This estimate includes typical cable loss (0.40 dB/km) and up to 11 splice losses (0.2 dB per splice). For 1310 nm OC-48 systems, dispersion is not a limiting factor, and the applications are attenuation-limited. Approximate Span Lengths can be calculated more precisely based on particular fiber and splice characteristics and local engineering rules.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 0 - 6 7
Technical Specifications
OC-48 DWDM Optical Specification (LNW121B-LNW159B,
LNW221-LNW259, and LNW421-LNW459)
............................................................................................................................................................................................................................................................
Overview
The following tables present the optical specifications for the OC-48
DWDM circuit packs.
System specifications
The following table lists the DWDM low-speed (tributary interface) and high-speed (network interface) system specifications.
Table 10-38 SONET Optical System Specifications
System Information
Optical Line Rate
Optical Line Coding
Optical Wavelength
Performance
Temperature Range
OC-48 low-speed DWDM Optics
(LNW421-LNW459)
2.488 Gb/s
Scrambled NRZ
1530 nm - 1560 nm
Customized LR-2 (for DWDM)
CO
OC-48 high-speed DWDM Optics
(LNW121B-159B & LNW221-259)
2.488 Gb/s
Scrambled NRZ
1530 nm - 1560 nm
Customized LR-2 (for DWDM)
CO
Important!
The LNW421, 423, 431, 433, 435, 437, 443, 445,
457 packs are no longer available. All other 400 series packs will still be available. The LNW121B, 123B, 131B, 133B, 135B,
137B, 143B, 145B, 147B, 149B, 157B, and 159B packs are no longer available. All other 100 series packs will still be available.
The LNW221, 243, and 257 packs are no longer available. All other 200 series packs will still be available.
...........................................................................................................................................................................................................................................................
1 0 - 6 8
365-372-300
Issue 8.0, September 2006
OC-48 DWDM Optics (LNW121B- LNW159B,
LNW221- LNW259, and LNW421-LNW459)
Technical Specifications
Transmitter specifications
The following table lists the DWDM optics transmitter information.
Table 10-39 SONET Optical Transmitter Information
Transmitter Info.
OC-48 low-speed DWDM Optics
(LNW421-LNW459)
Optical Device Temperature
Controller/Thermo-Electric
Cooler (TEC)
Transmission Medium
Yes
FDA Classification
Optical Source
Faceplate Optical Connector
Input Fiber:
Standard Single-Mode
Non-Dispersion Shifted Fiber
Output Fiber:
Standard Single-Mode
Non-Dispersion Shifted Fiber
Class I
Distributed Feed-Back (DFB) Laser or
Externally Modulated Laser (EML)
LC connector
OC-48 high-speed DWDM Optics
(LNW121B-159B & LNW221-259)
Yes
Input Fiber:
Standard Single-Mode
Non-Dispersion Shifted Fiber
Output Fiber:
Standard Single-Mode
Non-Dispersion Shifted Fiber
Class I
Distributed Feed-Back (DFB) Laser or
Externally Modulated Laser (EML)
LC connector
Receiver specifications
The following table lists the passive DWDM optics receiver information.
Table 10-40 SONET Optical Receiver Information
Receiver Information
Optical Detector
Faceplate Optical Connector
OC-48 low-speed DWDM Optics
(LNW421-LNW459)
Avalanche Photodiode (APD)
LC connector
OC-48 high-speed DWDM
Optics
(LNW121B-159B & LNW221-259)
Avalanche Photodiode (APD)
LC connector
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 0 - 6 9
OC-48 DWDM Optics (LNW121B- LNW159B,
LNW221- LNW259, and LNW421-LNW459)
Technical Specifications
Operating wavelengths
The table below lists the channel numbers, operating wavelengths, and frequencies that adhere to the ITU grid for the OC-48 DWDM OLIUs.
Table 10-41 OC-48 DWDM OLIUs Wavelength Plan
Port Unit
LNW121B, LNW221, & LNW421
LNW123B, LNW223, & LNW423
LNW125B, LNW225, & LNW425
LNW127B, LNW127, & LNW427
LNW131B, LNW231, & LNW431
LNW133B, LNW233, & LNW433
LNW135B, LNW235, & LNW435
LNW137B, LNW237, & LNW437
LNW143B, LNW243, & LNW443
LNW145B, LNW245, & LNW445
LNW147B, LNW247, & LNW447
LNW149B, LNW249, & LNW449
LNW153B, LNW253, & LNW453
LNW155B, LNW255, & LNW455
LNW157B, LNW257, & LNW457
LNW159B, LNW259, & LNW459
56
57
58
59
52
53
54
55
46
47
48
49
42
43
44
45
Channel #
21
22
23
24
31
32
33
34
25
26
27
28
35
36
37
38
1547.715
1546.917
1543.730
1542.936
1542.142
1541.349
1540.557
1539.766
1538.976
1538.186
1535.822
1535.036
1534.250
1533.465
1532.681
1531.898
1531.116
1530.334
Wavelength (nm)
1560.606
1559.794
1558.983
1558.173
1557.363
1556.555
1555.747
1554.940
1552.524
1551.721
1550.918
1550.116
1549.315
1548.515
193.70
193.80
194.20
194.30
194.40
194.50
194.60
194.70
194.80
194.90
195.20
195.30
195.40
195.50
195.60
195.70
195.80
195.90
Frequency (THz)
192.10
192.20
192.30
192.40
192.50
192.60
192.70
192.80
193.10
193.20
193.30
193.40
193.50
193.60
...........................................................................................................................................................................................................................................................
1 0 - 7 0
365-372-300
Issue 8.0, September 2006
OC-48 DWDM Optics (LNW121B- LNW159B,
LNW221- LNW259, and LNW421-LNW459)
Technical Specifications
Optical requirements and loss budgets
The table below lists the optical requirements and link budgets for the
OC-48 DWDM OLIUs.
Table 10-42 Optical Requirements and Link Budgets for the
OC-48 DWDM OLIUs
Parameter
Interface Type (Note 1)
DWDM Wavelength Range (100 GHz spacing)
Maximum Center Wavelength Deviation
Maximum Spectral Width
(∆λ
20
)
Maximum Transmitter Power
Minimum Transmitter Power
Maximum Received Power (1x10
-12
BER)
Minimum Received Power (1x10
-12
BER)
Minimum System Gain (see Note 2)
Dispersion
Optical Path Penalty (see Note 3)
Additional Connector Loss Margin
(see Note 4)
Additional Unallocated Margin
(see Note 5)
Minimum Loss Budget (see Note 6)
Maximum Loss Budget (see Note 7)
LNW121B-159B, LNW221-259,
LNW421-459
OC-48 Custom LR-2 for DWDM
1530.334-1560.606 nm
+/- 100 picometers
(+/ 12.5 GHz)
0.5 nm
+2.0 dBm
-1.0 dBm
-8.0 dBm
-29.0 dBm
28.0 dB
1800 ps/nm
2.0 dB
1.5 dB
1.5 dB
10.0 dB
23.0 dB
Approximate Span Length (see Note 8) 85 km*
*This span length assumes no passive optical unit (POU) is being used.
NOTES
1. All terminology is consistent with GR-253-CORE, Issue 3. All values are worst-case end of life (EOL). Optical specifications meet or exceed equivalent GR-253-CORE requirements.
2. The System Gain includes connector loss at the transmitter and receiver points S and R in GR-253-CORE, Issue 3.
3. Optical path penalty includes effects of dispersion, reflection, and
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 0 - 7 1
OC-48 DWDM Optics (LNW121B- LNW159B,
LNW221- LNW259, and LNW421-LNW459)
Technical Specifications
jitter that occur on the optical path. The optical path penalty for 1550 nm optics is normally 2.0 dB.
4. One additional connector (0.75 dB) on each end is assumed to connect station cable to outside plant.
5. Additional unallocated margin, or safety margin, can be 0-3 dB.
Typically, a 1.5 dB value is assumed.
6. For all packs where the Minimum Loss Budget (MLB) is 0, no attenuator is required for loopbacks. For all packs where the MLB is greater than 0, an attenuator is required. The value of the LBO shall be equal to or greater than the MLB. The MLB is found in the table above.
7. The stated maximum loss budget equals the System Gain, less the
Optical Path Penalty, the Additional Connector Loss Margin, and the
Additional Unallocated Margin. The resultant Maximum Loss
Budget is available for station cable loss, transmission cable loss, and splice loss. The stated maximum loss budget is conservative; i.e., if the additional connector loss margin and additional unallocated margin are not needed, an additional 3 dB budget is available.
8. The Approximate Span Length values are calculated per an attenuation assumption. As a general rule, for attenuation-limited systems, an attenuation of 0.27 dB/km is used for 1550 nm optics.
This estimate includes typical cable loss (0.22 dB/km) and up to 11 splice losses (0.2 dB per splice). For 1550 nm OC-48 systems, dispersion can also be a limiting factor. Approximate Span Lengths can be calculated more precisely based on particular fiber and splice characteristics and local engineering rules.
...........................................................................................................................................................................................................................................................
1 0 - 7 2
365-372-300
Issue 8.0, September 2006
Technical Specifications
SONET Optical Specifications: OC-192 OLIU (LNW59)
............................................................................................................................................................................................................................................................
Overview
The following tables present the optical specifications for the PTM modules approved for the LNW59.
Allowed Optics
The table below lists the PTM optics, also known as SFP/XFP optics, that may be used in the LNW59 circuit pack.
To ensure proper optical performance, mechanical fit, compliance with
EMC, and compliance with laser safety standards, the Lucent specified
PTM transceivers listed in the table below must be used.
Only the Lucent specified PTM transceivers listed below are compatible with DMX software. If non-Lucent specified PTM transceivers are installed in DMX, the system will reject that transceiver, and that optical port will become inoperable (until approved parts are installed).
Table 10-43 PTM Optics for LNW59
Apparatus Code
X10GMC2
Comcode
109603704
Description
OC192 XFP TRCVR
Short Reach, 1.3 SR-1 (2km),
1310nm
X10GMC4 109603712
Intermediate Reach, 1.5 IR-2
(40km), 1550nm
X10GMC5 109603720
Long Reach, 1.5 LR-2 (80km),
1550nm
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 0 - 7 3
SONET Optical Specifications: OC-192 OLIU
(LNW59)
Technical Specifications
System specifications
The table below lists the OC-192 OLIU system specifications.
Table 10-44 SONET Optical System Specifications
System Information
Optical Line Rate
Optical Line Coding
Optical Wavelength
Performance
Temperature Range
SR-1
9953.28 Mb/s
Scrambled NRZ
1310 nm
GR-253 OC-192 SR-1
(Short Reach)
Central Office
LNW59
IR-2
9953.28 Mb/s
Scrambled NRZ
1550 nm
GR-253 OC-192 IR-2
(Intermediate Reach)
Central Office
LR-2
9953.28 Mb/s
Scrambled NRZ
1550 nm
GR-253 OC-192 LR-2
(Long Reach)
Central Office
Transmitter Specifications
The table below lists the OC-192 OLIU transmitter information.
Table 10-45 SONET Optical Transmitter Information
Transmitter Info.
None
SR-1
None
LNW59
IR-2
None
LR-2
Optical Device
Temperature Controller
FDA Classification
Optical Source
Faceplate Optical
Connector
Class I
1310 nm, FP or DFB
Laser Structure
LC connector
Class I
1550 nm, ELM Laser
Structure
LC connector
Class I
1550 nm, ELM Laser
Structure
LC connector
...........................................................................................................................................................................................................................................................
1 0 - 7 4
365-372-300
Issue 8.0, September 2006
SONET Optical Specifications: OC-192 OLIU
(LNW59)
Technical Specifications
Receiver specifications
The table below lists the OC-192 OLIU receiver information.
Table 10-46 SONET Optical Receiver Information
Receiver Information
Optical Detector
Faceplate Optical Connector
SR-1
PIN Diode
LC connector
LNW59
IR-2
PIN Diode
LC connector
LR-2
APD
LC connector
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 0 - 7 5
SONET Optical Specifications: OC-192 OLIU
(LNW59)
Technical Specifications
Link budgets
The table below lists the OC-192 PTM link budgets for the LNW59.
The text in parenthesis denotes the apparatus code for the unified PTM equivalent of each pack.
Table 10-47 Optical Specifications and Link Budgets
Parameter (Note 1)
Minimum Wavelength
Maximum Wavelength
Maximum Spectral Width
(
∆λ
20
)
Maximum RMS Spectral Width (
σ
)
Minimum Side Mode Suppression Ratio
(SSR)
Maximum Transmitter Power
Minimum Transmitter Power
Maximum Received Power
Minimum Received Power
@ BER or 1x10
-12
Minimum System Gain
(see Note 2)
Maximum Dispersion
Optical Path Penalty (see Note 3)
Minimum Loss Budget
(see Note 4)
Maximum Loss Budget
(see Note 5)
Approximate Span Length
(see Note 6)
SR-1
1290 nm
1330 nm
1.0 nm
NA
30 dBm
-1 dBm
-6 dBm
-1 dBm
-11 dBm
5 dB
+6.6 ps/nm
1.0 dB
0.0 dB
4.0 dB
2 km
LNW59
IR-2
1530 nm
1565 nm
1.0 nm
NA
30 dB
+2.0 dBm
-1.0 dBm
-1.0 dBm
-14.0 dBm
13.0 dB
+800 ps/nm
2.0 dB
3.0 dB
11.0 dB
40 km
24.0 dB
+1600 ps/nm
2.0 dB
11.0 dB
22.0 dB
80 km
LR-2
1530 nm
1565 nm
TBD
NA
30 dB
+4.0 dBm
0.0 dBm
-7.0 dBm
-24.0 dBm
NOTES
1. All terminology is consistent with GR-253-CORE, Issue 3 and ITU
G.693. All values are worst-case end of life. Optical specifications meet or exceed equivalent GR-253-CORE requirements.
2. The system gain includes connector loss at the transmitter and receiver points S and R in GR-253-CORE, Issue 3.
...........................................................................................................................................................................................................................................................
1 0 - 7 6
365-372-300
Issue 8.0, September 2006
SONET Optical Specifications: OC-192 OLIU
(LNW59)
Technical Specifications
3. Optical path penalty includes effects of dispersion, reflection, and jitter that occur on the optical path. The optical path penalty for 1310 nm is a maximum of 1.0 dB. The optical path penalty for 1550 nm is a maximum of 2.0 dB.
4. For all packs where the Minimum Loss Budget (MLB) is 0, no attenuator is required for loopbacks. For all packs where the MLB is greater than 0, an attenuator is required. The value of the LBO shall be equal to or greater than the MLB. The MLB is found in the table above.
5. The stated maximum loss budget equals the miniumum system gain, minus the optical path penalty. Maximum loss budget is available for both station and transmission cable and splices.
6. The Approximate Span Length values are calculated per an attenuation assumption. As a general rule, for attenuation-limited systems, an attenuation of 0.27 dB/km is used for 1550 nm optics.
This estimate includes typical cable loss (0.22 dB/km) and up to 11 splice losses (0.2 dB per splice). For 1550 nm OC-192 systems, dispersion can also be a limiting factor. Approximate Span Lengths can be calculated more precisely based on particular fiber and splice characteristics and local engineering rules.
.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 0 - 7 7
Technical Specifications
SONET Optical Specifications: OC-192 OLIU (LNW56 and LNW58)
............................................................................................................................................................................................................................................................
Overview
The following tables present the optical specifications for the OC-192
OLIUs.
System specifications
The table below lists the OC-192 OLIU system specifications.
Table 10-48 SONET Optical System Specifications
System Information LNW58
Optical Line Rate
Optical Line Coding
9953.28 Mb/s
Scrambled NRZ
Optical Wavelength
Performance
Temperature Range
1310 nm
ITU-T G.693
VSR600-2R1
(Very Short Reach)
Central Office
LNW56
9953.28 Mb/s
Scrambled NRZ
1550 nm
GR-253 OC-192 IR-2
(Intermediate Reach)
Central Office
Transmitter Specifications
The table below lists the OC-192 OLIU transmitter information.
Table 10-49 SONET Optical Transmitter Information
Transmitter Info.
Optical Device
Temperature Controller
FDA Classification
Optical Source
Faceplate Optical
Connector
LNW58
None
Class I
1310 nm, FP or DFB
Laser Structure
LC connector
LNW56
None
Class I
1550 nm, ELM Laser
Structure
LC connector
...........................................................................................................................................................................................................................................................
1 0 - 7 8
365-372-300
Issue 8.0, September 2006
SONET Optical Specifications: OC-192 OLIU
(LNW56 and LNW58)
Technical Specifications
Receiver specifications
The table below lists the OC-192 OLIU receiver information.
Table 10-50 SONET Optical Receiver Information
Receiver Information
Optical Detector
Faceplate Optical Connector
LNW58
PIN Diode
LC connector
LNW56
PIN Diode
LC connector
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 0 - 7 9
SONET Optical Specifications: OC-192 OLIU
(LNW56 and LNW58)
Link budgets
The table below lists the OC-192 OLIU link budgets.
Technical Specifications
Table 10-51 Optical Specifications and Link Budgets
Parameter (Note 1)
Minimum Wavelength
Maximum Wavelength
Maximum Spectral Width
(
∆λ
20
)
Maximum RMS Spectral Width (
σ
)
Minimum Side Mode Suppression Ratio
(SSR)
Maximum Transmitter Power
Minimum Transmitter Power
Maximum Received Power
Minimum Received Power
@ BER or 1x10
-12
Minimum System Gain
(see Note 2)
Dispersion
Optical Path Penalty (see Note 3)
Optical Signal to Noise Ratio (OSNR);
1x10
-12
BER, -10 to -20 dBm, +1600 ps/nm, 0.1 nm RBW
Minimum Loss Budget
(see Note 4)
Maximum Loss Budget
(see Note 5)
Approximate Span Length
(see Note 6)
LNW58
1260 nm
1360 nm
NA
3.0 nm
NA
-1.0 dBm
-6.0 dBm
-1.0 dBm
-11.0 dBm
5.0 dB
NA
1.0 dB
NA
0.0 dB
4.0 dB
600 meters
LNW56
1530 nm
1565 nm
1.0 nm
NA
30 dB
+2.0 dBm
-1.0 dBm
-1.0 dBm
-14.0 dBm
13.0 dB
+800 ps/nm
2.0 dB
NA
3.0 dB
11.0 dB
40 km
NOTES
1. All terminology is consistent with GR-253-CORE, Issue 3 and ITU
G.693. All values are worst-case end of life. Optical specifications meet or exceed equivalent GR-253-CORE requirements.
2. The system gain includes connector loss at the transmitter and receiver points S and R in GR-253-CORE, Issue 3.
3. Optical path penalty includes effects of dispersion, reflection, and jitter that occur on the optical path. The optical path penalty for 1310
...........................................................................................................................................................................................................................................................
1 0 - 8 0
365-372-300
Issue 8.0, September 2006
SONET Optical Specifications: OC-192 OLIU
(LNW56 and LNW58)
Technical Specifications
nm is a maximum of 1.0 dB. The optical path penalty for 1550 nm is a maximum of 2.0 dB.
4. For all packs where the Minimum Loss Budget (MLB) is 0, no attenuator is required for loopbacks. For all packs where the MLB is greater than 0, an attenuator is required. The value of the LBO shall be equal to or greater than the MLB. The MLB is found in the table above.
5. The stated maximum loss budget equals the miniumum system gain, minus the optical path penalty. Maximum loss budget is available for both station and transmission cable and splices.
6. The Approximate Span Length values are calculated per an attenuation assumption. As a general rule, for attenuation-limited systems, an attenuation of 0.27 dB/km is used for 1550 nm optics.
This estimate includes typical cable loss (0.22 dB/km) and up to 11 splice losses (0.2 dB per splice). For 1550 nm OC-192 systems, dispersion can also be a limiting factor. Approximate Span Lengths can be calculated more precisely based on particular fiber and splice characteristics and local engineering rules.
Note that the 1310 nm VSR OC-192 LNW58 is recommended for spans of up to 600 meters only.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 0 - 8 1
Technical Specifications
SONET Optical Specifications: OC-192 OLIU (LNW57 and LNW60)
............................................................................................................................................................................................................................................................
Overview
The following tables present the optical specifications for the OC-192
OLIUs.
System specifications
The table below lists the OC-192 OLIU system specifications.
Table 10-52 SONET Optical System Specifications
System Information LNW57
Optical Line Rate 9953.28 Mb/s
Optical Line Coding
Optical Wavelength
Performance
Temperature Range
Scrambled NRZ
1533.465 nm
GR-253 OC-192 LR-2
(Long Reach)
Central Office
LNW60
9953.28 Mb/s
Scrambled NRZ
1533.465 nm
GR-253 OC-192 LR-2+
(Extended Long Reach)
Central Office
Important!
The LNW57 and LNW60 circuit packs utilize a
“dither tone” to frequency modulate the laser. This technique is used to minimize the effects of Stimulated Brillouin Scattering
(SBS).
At high optical launch powers, SBS can cause an acoustic back-scattering phenomenon in fibers. The dither tone effectively broadens the spectrum of the narrow optical pulse, thus raising the threshold power where SBS becomes an issue.
Normally, Lucent recommends that the optical output of the
OC-192 circuit packs be amplified to no more than +10 dBm.
However, with the dither tone circuit incorporated into the
LNW57 and LNW60, optical amplification of the LNW57 to higher power levels is acceptable. The LNW60 is already amplified by an on-board optical amplifier.
For fibers carrying multiple wavelengths in DWDM systems, it should be noted that the individual channel (individual wavelength) power determines the SBS threshold, not the total composite power of all the channels.
...........................................................................................................................................................................................................................................................
1 0 - 8 2
365-372-300
Issue 8.0, September 2006
SONET Optical Specifications: OC-192 OLIU
(LNW57 and LNW60)
Technical Specifications
Transmitter Specifications
The table below lists the OC-192 OLIU transmitter information.
Table 10-53 SONET Optical Transmitter Information
Transmitter Info.
Optical Device
Temperature Controller
FDA Classification
Optical Source
LNW57
None
Class I
1550 nm, Externally
Modulated Mach-Zehnder
Type
Faceplate Optical
Connector
LC connector
LNW60
None
Class 1M (IEC 60825)
1550 nm, Externally
Modulated Mach-Zehnder
Type with an On-Board
Optical Amplifier
LC connector
Receiver specifications
The table below lists the OC-192 OLIU receiver information.
Table 10-54 SONET Optical Receiver Information
Receiver Information
Optical Detector
Faceplate Optical Connector
LNW57
Avalanche Photo
Diode (APD)
LC connector
LNW60
Avalanche Photo Diode (APD) with Improved Tolerance to Chromatic
Dispersion in the Signal
LC connector
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 0 - 8 3
SONET Optical Specifications: OC-192 OLIU
(LNW57 and LNW60)
Technical Specifications
Link budgets
The table below lists the OC-192 OLIU link budgets.
Table 10-55 Optical Specifications and Link Budgets
Parameter (Note 1)
Minimum Wavelength (see Note 7)
Maximum Wavelength (see Note 7)
Maximum Spectral Width
(
∆λ
)
Minimum Side Mode Suppression Ratio
(SSR)
Maximum Transmitter Power
Minimum Transmitter Power
Maximum Received Power
Minimum Received Power
@ BER or 1x10
-12
Minimum System Gain
(see Note 2)
Dispersion
Optical Path Penalty (see Note 3)
Optical Signal to Noise Ratio (OSNR);
1x10
-12
BER, -10 to -20 dBm, +1600 ps/nm, 0.1 nm RBW
Minimum Loss Budget
(see Note 4)
Maximum Loss Budget
(see Note 5)
Approximate Span Length
(see Note 6)
LNW57 LNW60
1533.405 nm 1533.405 nm
1533.525 nm 1533.525 nm
0.04 nm 0.04 nm
30 dB 30 dB
+6.0 dBm
+3.0 dBm
-7.0 dBm
-24.0 dBm
27.0 dB
+12.5 dBm
+11.5 dBm
-7.0 dBm
-24.0 dBm
35.5 dB
+1600 ps/nm +2000 ps/nm
2.0 dB 2.0 dB
23.0
21.0
13.0 dB
25.0 dB
92 km
19.5 dB
33.5 dB
124 km
NOTES
1. All terminology is consistent with GR-253-CORE, Issue 3 and ITU
G.693. All values are worst-case end of life. Optical specifications meet or exceed equivalent GR-253-CORE requirements.
2. The system gain includes connector loss at the transmitter and receiver points S and R in GR-253-CORE, Issue 3.
3. Optical path penalty includes effects of dispersion, reflection, and jitter that occur on the optical path. The optical path penalty for 1310
...........................................................................................................................................................................................................................................................
1 0 - 8 4
365-372-300
Issue 8.0, September 2006
SONET Optical Specifications: OC-192 OLIU
(LNW57 and LNW60)
Technical Specifications
nm is a maximum of 1.0 dB. The optical path penalty for 1550 nm is a maximum of 2.0 dB.
4. For all packs where the Minimum Loss Budget (MLB) is 0, no attenuator is required for loopbacks. For all packs where the MLB is greater than 0, an attenuator is required. The value of the LBO shall be equal to or greater than the MLB. The MLB is found in the table above.
5. The stated maximum loss budget equals the miniumum system gain, minus the optical path penalty. Maximum loss budget is available for both station and transmission cable and splices.
6. The Approximate Span Length values are calculated per an attenuation assumption. As a general rule, for attenuation-limited systems, an attenuation of 0.27 dB/km is used for 1550 nm optics.
This estimate includes cable loss and and splice losses. For 1550 nm
OC-192 systems, dispersion can also be a limiting factor.
Approximate Span Lengths can be calculated more precisely based on particular fiber and splice characteristics and local engineering rules.
Important!
With the LNW57, span lengths of 92 km are possible as long as total dispersion is less than 1600 ps/nm. With the LNW60, span lengths of 124 km are possible as long as total dispersion is less than 2000 ps/nm.
7. The transmitted wavelength of the LNW57 and LNW60 circuit packs is a fixed single wavelength of nominally 1533.465 nm, 195.5 THz
(single-color, Ch 55). The Maximum Center Wavelength Deviation is
+/- 60 picometers (+/- 12.5 GHz).
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 0 - 8 5
Technical Specifications
DWDM OC-192 OLIUs (LNW523, LNW527, LNW554, and
LNW555) Optical Specification
............................................................................................................................................................................................................................................................
Overview
The following tables present the optical specifications for the OC-192
LNW523, LNW527, LNW554 and LNW555 OLIU.
System specifications
The table below lists the LNW523, LNW527, LNW554, and LNW555
OC-192 OLIU system specifications.
Table 10-56 SONET Optical System Specifications
System
Information
LNW523
Optical Line Rate 9953.28 Mb/s
Optical Line
Coding
Scrambled NRZ
LNW527
9953.28 Mb/s
Scrambled NRZ
LNW554
9953.28 Mb/s
Scrambled NRZ
Optical Wavelength
*
=See Note
Performance
1550 nm*
(4 tunable wavelengths)
1550 nm*
(4 tunable wavelengths)
1550 nm*
(4 tunable wavelengths)
Modified GR-253
OC-192 LR-2 (Long
Reach)
Modified GR-253
OC-192 LR-2 (Long
Reach)
Modified GR-253
OC-192 LR-2
(Long Reach)
Temperature Range Central Office Central Office Central Office
LNW555
9953.28 Mb/s
Scrambled NRZ
1533.465 nm
Modified GR-253
OC-192 LR-2 (Long
Reach)
Central Office
Note
*: See Table 10-59 for tunable wavelength frequencies.
Important!
The LNW555 circuit pack can operate as either an
• 80 km long-reach TDM optical interface
• 80 km long-reach DWDM optical interface
(single-color CH 55) capable of interfacing with the passive optics filters
In either application, the transmitted wavelength is a fixed, single wavelength 1533.465 nm/195.5 THz.
...........................................................................................................................................................................................................................................................
1 0 - 8 6
365-372-300
Issue 8.0, September 2006
DWDM OC-192 OLIUs (LNW523, LNW527, LNW554, and
LNW555)
Technical Specifications
Transmitter Information
The table below lists the LNW523, LNW527, LNW554, and LNW555
OC-192 OLIU transmitter information.
Table 10-57 SONET Optical Transmitter Information
Transmitter Info. LNW523
Optical Device
Temperature
Controller
None
FDA Classification Class I
Optical Source
Faceplate Optical
Connector
LNW527
None
Class I
LNW554
None
Class I
1550 nm Externally
Modulated Mach-
Zehnder Type
1550 nm Externally
Modulated Mach-
Zehnder Type
1550 nm Externally
Modulated
Mach-Zehnder Type
LC connector LC connector LC connector
LNW555
None
Class I
1550 nm Externally
Modulated
Mach-Zehnder Type
LC connector
Receiver specifications
The table below lists the LNW523, LNW527, LNW554, and LNW555
OC-192 OLIU receiver information.
Table 10-58 SONET Optical Receiver Information
Receiver Information LNW523 LNW527 LNW554 LNW555
Optical Detector Avalanche
Photo Diode
(APD)
Avalanche
Photo Diode
(APD)
Avalanche
Photo Diode
(APD)
Avalanche
Photo Diode
(APD)
Faceplate Optical Connector LC connector LC connector LC connector LC connector
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
8 7 1 0 -
DWDM OC-192 OLIUs (LNW523, LNW527, LNW554, and
LNW555)
Technical Specifications
Operating wavelengths
The LNW523/527/554 employ tunable lasers that support 4 separate frequencies on each pack. Using software controls, the
LNW523/527/554 lasers can be made to transmit different wavelengths.
The LNW555 employs a fixed laser that transmits a single wavelength at 1533.465 nm (ch 55).
The table below lists the channel numbers, operating wavelengths, and frequencies that adhere to the ITU grid for OC-192 DWDM OLIUs.
Table 10-59 OC-192 DWDM OLIUs Wavelength Plan
Circuit Pack
LNW523
Channel #
21
22
23
24
Wavelength (nm) Frequency (Thz)
1560.606 192.1
1559.794 192.2
1558.983 192.3
1558.173 192.4
LNW527
LNW554
LNW555
25
26
27
28
52
53
54
55
55
1557.363 192.5
1556.555 192.6
1555.747 192.7
1554.940 192.8
1535.822 195.2
1535.036 195.3
1534.250 195.4
1533.465 195.5
1533.465 195.5
...........................................................................................................................................................................................................................................................
1 0 - 8 8
365-372-300
Issue 8.0, September 2006
DWDM OC-192 OLIUs (LNW523, LNW527, LNW554, and
LNW555)
Technical Specifications
Link budgets
The table below lists the OC-192 LNW523, LNW527, LNW554, and
LNW555 OLIU link budgets.
Table 10-60 Optical Specifications and Link Budgets
Parameter (Note 1)
Minimum Wavelength
Maximum Wavelength
Maximum Center Wavelength
Deviation
Maximum Spectral Width
(
∆λ
20
) TBD
Maximum RMS Spectral Width (
σ
) NA
30 dB Minimum Side Mode Suppression
Ratio (SSR)
Maximum Transmitter Power
LNW523 LNW527 LNW554 LNW555
1560.606 nm 1557.363 nm 1535.822 nm 1533.465 nm
1558.173 nm 1554.940 nm 1533.465 nm
(see Note 7)
TBD
+/- 60 picometers
(+/ 7.5 GHz)
TBD TBD
+6.0 dBm
NA
30 dB
NA
30 dB
NA
NA
Minimum Transmitter Power
Maximum Received Power
Minimum Received Power
Minimum System Gain
(see Note 2)
Dispersion
Optical Path Penalty (see Note 3)
+3.0 dBm
-7.0 dBm
-24.0 dBm
27.0 dB
+6.0 dBm
+3.0 dBm
-7.0 dBm
-24.0 dBm
27.0 dB
+6.0 dBm
+3.0 dBm
-7.0 dBm
-24.0 dBm
27.0 dB
+6.0 dBm
+2.0 dBm
-9.0 dBm
-22.0 dBm
24.0 dB
+1600 ps/nm +1600 ps/nm +1600 ps/nm +1600 ps/nm
2.0 dB 2.0 dB 2.0 dB 2.0 dB
TBD TBD TBD NA Optical Signal to Noise Ratio
(OSNR); 1x10
-12
BER, -10 to -20 dBm, +1600 ps/nm, 0.1 nm RBW
Minimum Loss Budget
(see Note 4)
Maximum Loss Budget
(see Note 5)
Approximate Span Length
(see Note 6)
13.0 dB
25.0 dB
92 km
13.0 dB
25.0 dB
92 km
13.0 dB
25.0 dB
92 km
15.0 dB
22.0 dB
81 km
NOTES
1. All terminology is consistent with GR-253-CORE, Issue 3. All values are worst-case end of life. Optical specifications meet or exceed equivalent GR-253-CORE requirements.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 0 - 8 9
DWDM OC-192 OLIUs (LNW523, LNW527, LNW554, and
LNW555)
Technical Specifications
2. The system gain includes connector loss at the transmitter and receiver points S and R in GR-253-CORE, Issue 3.
3. Optical path penalty includes effects of dispersion, reflection, and jitter that occur on the optical path. The optical path penalty for 1310 nm is a maximum of 1.0 dB. The optical path penalty for 1550 nm is a maximum of 2.0 dB.
4. For all packs where the Minimum Loss Budget (MLB) is 0, no attenuator is required for loopbacks. For all packs where the MLB is greater than 0, an attenuator is required. The value of the LBO shall be equal to or greater than the MLB. The MLB is found in the table above.
5. The stated maximum loss budget equals the miniumum system gain, minus the optical path penalty. Maximum loss budget is available for both station and transmission cable and splices.
6. The Approximate Span Length values are calculated per an attenuation assumption. As a general rule, for attenuation-limited systems, an attenuation of 0.27 dB/km is used for 1550 nm optics.
This estimate includes cable loss and splice losses. For 1550 nm
OC-192 systems, dispersion can also be limiting factor. Approximate
Span Lengths can be calculated more precisely based on particular fiber and splice characteristics and local engineering rules.
Important!
With the LNW523, LNW527, and LNW524 span length of 92 km are possible as long as the maximum dispersion is less than 1600ps/nm.
7. The transmitted wavelength of the LNW555 circuit pack is a fixed single wavelength of 1533.465 nm/195.5 THz (single-color, CH 55).
...........................................................................................................................................................................................................................................................
1 0 - 9 0
365-372-300
Issue 8.0, September 2006
Technical Specifications
Lightguide Jumpers and Buildouts
............................................................................................................................................................................................................................................................
Overview
The DMX provides standard LC-type connectors on all optical interfaces. 5 dB, 10 dB, 15 dB, and 20 dB attenuating build-outs are supported.
Single-mode jumpers
The OC-3, OC-12, OC-48, OC-192, and 1000BASE-LX lightguide interfaces use single-mode jumpers for connecting to and from the outside plant LGX panel and the DMX.
Multi-mode jumpers
The 1000BASE-SX interface must use multi-mode jumpers.
Build-outs
DMX supports the use of single-mode to single-mode (SM-SM) fiber exclusively, except on the 1000BASE-SX interface.
Reference
For more information, including a complete list of available jumpers and build-outs, refer to the Miscellaneous Equipment and Tools section in Chapter 7, Ordering.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 0 - 9 1
Technical Specifications
Multimode Fiber Transmission with
OC-3 and OC-12 circuit packs
Overview
............................................................................................................................................................................................................................................................
Purpose
This section details the use of OC-3 and OC-12 circuit packs to transmit signals over Multi-Mode Fiber (MMF).
OC-3 and OC-12 circuit packs used on DMX are designed to meet or exceed Optical Performance Standards per Telcordia GR-253 CORE on standard Single-Mode Fiber (SMF). This section reflects the results of tests demonstrating successful transmission over shorter distances of
MMF.
Based on this testing, transmission of OC-3 and OC-12 signals over
MMF can be supported by a DMX system equipped with LNW36,
LNW46, or LNW50 circuit packs within the limits specified in this section.
...........................................................................................................................................................................................................................................................
1 0 - 9 2
365-372-300
Issue 8.0, September 2006
Technical Specifications
Background Information
............................................................................................................................................................................................................................................................
Core Diameters
Standard SMF core diameters are specified to be in the range of
8-10
µ m
.
MMF core diameters are specified to be 50
µ m or 62.5
µ m
.
Receiver Ports
All existing DMX circuit pack codes that utilize OC-3 or OC-12 optical interfaces incorporate optical receiver ports that accept optical inputs from fiber cores up to 62.5
µ m in diameter. Therefore, the receivers are designed to capture all of the incoming light from both SMF and MMF.
Transmitter Ports
The LNW36, LNW46, and LNW50 circuit packs utilize optical interfaces that incorporate laser transmitter ports designed to launch into
8-10
µ m
SMF. The laser transmitters in these circuit packs are Distributed Feedback (DFB) or Single Longitudinal (SLM) mode lasers.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 0 - 9 3
Technical Specifications
Recommendations
............................................................................................................................................................................................................................................................
Recommendations
With multi-mode fiber specified to meet 1 GbE fiber standards per the original IEEE 802.3z
TM
(now found in IEEE 802.3-2002) and rated at
500 MHz-km or greater, “Single-mode Fiber Offset-Launch Mode-
Conditioning Patch Cords” (Mode-Conditioning Patch Cord) are required for the transmitter ports of LNW36, LNW46, and LNW50 circuit packs. Mode-Conditioning Patch Cords take the transmitter port output from the single-mode fiber and couple it to the multi-mode fiber core at an offset. This offset launch into the MMF minimizes differential mode delay and modal dispersion. With the use of Mode-Conditioning patch cords, transmission distances of up to 300 meters are
allowed (refer to Figure 10-1).
With improved, recently introduced MMF specified to exceed 1 GbE fiber standards, transmission distances of up to 300 meters are allowed without the use of Mode-Conditioning patch cords. Several manufacturers offer this improved MMF (see the table below). These fibers, or their equivalents, do not require Mode-Conditioning patch cords when used with the LNW36, LNW46, and LNW50 circuit pack codes.
MMF Types that Do Not Require Mode-Conditioning Patch Cords
Manufacturer
Product Name Core Size
GigaGuide 62.5
OFS Fitel
OFS Fitel
Corning
Draka Comteq
GigaGuide 62.5 XL
InfiniCor CL 1000
HiCap 62.5 mm
62.5
µ m
62.5
µ m
62.5
µ m
62.5
µ m
Per usual practice, one must adhere to Lucent’s receiver overload and sensitivity specifications for the circuit pack codes listed above. Multimode attenuators may be needed at the LGX.
...........................................................................................................................................................................................................................................................
1 0 - 9 4
365-372-300
Issue 8.0, September 2006
Recommendations
Technical Specifications
Figure 10-1 Transmission Over Multi-Mode Fiber
Connection Diagram using:
Single-Mode Fiber Offset-Launch Mode-Conditioning
Patch Cord
Duplex mode-conditioning patch cord*
DMX
OC-3 or OC-12 circuit pack:
LNW36, LNW46, LNW50
TX
RX
SMF
MMF
LC LC
LC LC
SMF
Offset
Splice
MMF
SC SC
MMF
SC SC
MMF
MMF
LGX
LC = LC type optical connector
SC = SC type optical connector
SMF = single-mode fiber
MMF = multi-mode fiber
* Mode-Conditioning Patch Cord
may extend to the LGX
MMF
MMF
Other Terminal Equipment
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 0 - 9 5
Technical Specifications
Ethernet/SAN Optical Specifications
Overview
............................................................................................................................................................................................................................................................
Purpose
This section contains technical specifications for the optical interfaces for the Ethernet/SAN OLIUs.
Contents
The following optical interfaces are discussed in this section:
4-port GbE PTM (1000BASE-TX and/or
1000BASE-SX/LX/ZX) Private Line Optical Ethernet
8-port GbE PTM (1000BASE-TX and/or
1000BASE-SX/LX/ZX) Private Line Optical Ethernet
Short-reach GbE (1000BASE-SX) Optical Ethernet
Long-reach GbE (1000BASE-LX) Optical Ethernet
GbE (1000BASE-X)/ Fast-E (100BASE-LX/TX)
Optical/Electrical Ethernet (LNW70)
FC-DATA: FICON/ESCON/Fibre-Channel (LNW73 and
LNW73C) SAN Transport Interface
10/100T (10/100BASE-T)/ Fast-E (100BASE-LX)
Electrical/Optical Ethernet Private Line (LNW74)
RPR Enabled GbE (1000BASE-X)/ Fast-E
(100BASE-LX/TX) Optical Ethernet (LNW78)
1000BASE-SX Optical Ethernet/SAN Specification
1000BASE-LX Optical Ethernet/SAN Specification
1000BASE-ZX Optical Ethernet/SAN Specification
100BASE-LX Optical Ethernet Specification
ESCON SAN Transport Specification (LNW73 and
...........................................................................................................................................................................................................................................................
1 0 - 9 6
365-372-300
Issue 8.0, September 2006
Technical Specifications
4-port GbE PTM (1000BASE-TX and/or 1000BASE-SX/LX/ZX)
Private Line Optical Ethernet (LNW63)
............................................................................................................................................................................................................................................................
Description
The LNW63 provides 4 PTM ports that can be equipped with very long-reach (1000BASE-ZX) 1550 nm, long-reach (1000BASE-LX)
1310 nm, and/or short-reach (1000BASE-SX) 850 nm optical PTMs.
LNW63 can also be equipped with 100/1000BASE-TX electrical
Ethernet SFPs used in the LNW70, though only 1000BASE-TX rates are supported on the LNW63.
The LNW63 provides data transport at the rate of 1000 Mbps using standard encapsulation according to ANSI T1X1.5/2000-024R4 (ITU
G.7041), and standard STS-1 virtual concatenation according to ITU
G.707. The LNW63 is an unprotected pack.
Prior to Release 7.0, LNW63 packs could only be placed in Slot 1 of any function group or growth slot in the shelf (A1-G1) and DMX supported a total add/drop capacity of 20 private line GbE ports if all slots are equipped with LNW63 circuit packs.
When DMX is equipped with VLF Main (LNW59) packs, Ethernet packs can occupy both Slot 1 and 2 of a Function or Growth Unit
(where applicable). With VLF Mains and all tributary slots populated with LNW63 packs, DMX provides a total add/drop capacity of 40 private line GbE ports.
Prior to Release 7.0 (and when VLF Mains are not used), if the LNW63 circuit packs occupy slot 1 of a Function Unit group, slot 2 must be populated with an apparatus blank.
The LNW63 contains 4 internal 1000 Mbps WAN ports supporting enhanced private line services such as low-order virtual concatenation
(VT1.5) and Link Capacity Adjustment Scheme (LCAS). The LNW63 and PTM optics are also OSP hardened for outside plant applications.
Optical Specification
The LNW63 utilizes 1000BASE-SX/LX/ZX PTM optics. Refer to the sections entitled
1000BASE-SX Optical Ethernet/SAN Specification
1000BASE-LX Optical Ethernet/SAN Specification
specifications of these optics.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 0 - 9 7
4-port GbE PTM (1000BASE-TX and/or 1000BASE-SX/LX/ZX)
Private Line Optical Ethernet (LNW63)
Technical Specifications
Performance monitoring
Performance monitoring capabilities are available on the GbE circuit packs. A detailed list of monitored parameters can be found in
Appendix B.
...........................................................................................................................................................................................................................................................
1 0 - 9 8
365-372-300
Issue 8.0, September 2006
Technical Specifications
8-port GbE PTM (1000BASE-TX and/or 1000BASE-SX/LX/ZX)
Private Line Optical Ethernet (LNW64)
............................................................................................................................................................................................................................................................
Description
The LNW64 provides 8 private line, PTM (also known as SFP) GbE ports. The ports can be equipped with 8 1000BASE-SX/LX/ZX PTMs or 8 100/1000BASE-TX electrical PTMs, though only 1000BASE-TX rates are supported on the LNW64. LNW64 can also support a mix of 4 electrical and 4 optical PTMs. The LNW64 contains 8 internal VCG ports supporting enhanced private line services such as virtual concatenation and Link Capacity Adjustment Scheme (LCAS).
LNW64 is OSP hardened and can only be used with VLF Mains
(LNW59).
LNW64 supports STS-1 and STS-3c cross-connections with or without
VCAT, and STS-12c cross-connections without VCAT. All ports are capable of transmitting at wire speed (1000 Mbps) simultaneously, making full capacity of the pack 168 STS-1s. With VLF Mains,
LNW64 can occupy both slots 1 and 2 of a Function/Growth unit, making the total capacity of a systems fully populated with LNW64s,
80 GbE private line ports.
Optical Specification
The LNW64 utilizes 1000BASE-SX/LX/ZX PTM optics. Refer to the sections entitled
1000BASE-SX Optical Ethernet/SAN Specification
1000BASE-LX Optical Ethernet/SAN Specification
specifications of these optics.
Performance monitoring
Performance monitoring capabilities are available on the GbE circuit packs. A detailed list of monitored parameters can be found in
Appendix B.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 0 - 9 9
Technical Specifications
Short-reach GbE (1000BASE-SX) Optical Ethernet (LNW67)
............................................................................................................................................................................................................................................................
Description
This 2-port Ethernet interface provides short-reach high-speed optical data transport at the rate of 1 Gb/s using standard Ethernet switching
IEEE 802.1, standard encapsulation according to ANSI
T1X1.5/2000-024R4 (ITU G.7041), and standard STS-1 virtual concatenation according to ITU G.707. The LNW67 is an unprotected pack. Fiber access is provided by two LC-type connector pairs on the
LNW67 faceplate. The LNW67 transmits signals at a wavelength of
850nm. The LNW67 requires the use of multi-mode fiber cable. Each
LNW67 circuit pack can support 2 packet rings or 2 GbE private lines
(protected or unprotected).
Prior to Release 7.0, LNW67 packs could only be placed in Slot 1 of any function group or growth slot in the shelf (A1-G1) and DMX supported a total add/drop capacity of 10 optical GbE ports if all slots are equipped with LNW67 circuit packs.
When DMX is equipped with VLF Main (LNW59) packs, Ethernet packs can occupy both Slot 1 and 2 of a Function or Growth Unit
(where applicable). With VLF Mains and all tributary slots populated with LNW67 packs, DMX provides a total add/drop capacity of 20 optical GbE ports.
Prior to Release 7.0 (and when VLF Mains are not used), if the LNW67 circuit packs occupy slot 1 of a Function Unit group, slot 2 must be populated with an apparatus blank.
Important!
The LNW67 is being DA’d and will no longer be available as of 3/1/08.
Optical Specification
The LNW67 utilizes 1000BASE-SX optics. Refer to the section entitled
1000BASE-SX Optical Ethernet/SAN Specification
specifications of these optics.
Performance monitoring
Performance monitoring capabilities are available on the GbE circuit packs. A detailed list of monitored parameters can be found in
Appendix B.
...........................................................................................................................................................................................................................................................
1 0 - 1 0 0
365-372-300
Issue 8.0, September 2006
Technical Specifications
Long-reach GbE (1000BASE-LX) Optical Ethernet (LNW68)
............................................................................................................................................................................................................................................................
Description
This 2-port Ethernet interface provides long-reach high-speed optical data transport at the rate of 1 Gb/s using standard Ethernet switching
IEEE 802.1, standard encapsulation according to ANSI
T1X1.5/2000-024R4 (ITU G.7041), and standard STS-1 virtual concatenation according to ITU G.707. The LNW68 is an unprotected pack. Fiber access is provided by two LC-type connector pairs on the
LNW68 faceplate. The LNW68 transmits signals at a wavelength of
1310nm. The LNW68 requires the use of single-mode fiber cable. Each
LNW68 circuit pack can support 2 packet rings or 2 GbE private lines
(protected or unprotected).
Prior to Release 7.0, LNW68 packs could only be placed in Slot 1 of any function group or growth slot in the shelf (A1-G1) and DMX supported a total add/drop capacity of 10 optical GbE ports if all slots are equipped with LNW68 circuit packs.
When DMX is equipped with VLF Main (LNW59) packs, Ethernet packs can occupy both Slot 1 and 2 of a Function or Growth Unit
(where applicable). With VLF Mains and all tributary slots populated with LNW68 packs, DMX provides a total add/drop capacity of 20 optical GbE ports.
Prior to Release 7.0 (and when VLF Mains are not used), if the LNW68 circuit packs occupy slot 1 of a Function Unit group, slot 2 must be populated with an apparatus blank.
Important!
The LNW68 is being DA’d and will no longer be available as of 3/1/08.
Optical Specification
The LNW68 utilizes 1000BASE-LX optics. Refer to the section entitled
1000BASE-LX Optical Ethernet/SAN Specification
for the detailed specifications of these optics.
Performance monitoring
Performance monitoring capabilities are available on the GbE circuit packs. A detailed list of monitored parameters can be found in
Appendix B.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 0 - 1 0 1
Technical Specifications
GbE (1000BASE-X)/ Fast-E (100BASE-LX/TX) Optical/Electrical
Ethernet (LNW70)
............................................................................................................................................................................................................................................................
Description
The LNW70 circuit pack provides four 1000BASE-X (SX, LX, and/or
ZX— very long reach 80km), IEEE 802.3-compliant (1000Mbps) GbE interfaces and four 100BASE-LX IEEE 802.3-compliant (100 Mbps) fast Ethernet interfaces. The LNW70 circuit pack performs protocol transparent filtering and bridging of incoming media access control
(MAC) frames. MAC frames with a destination address on the local bus are filtered by the LNW70 to prevent unnecessary transmission of frames over the wide area network (WAN). Protection is provided via
SONET UPSR/BLSR or through the IEEE 802.1w (or 802.1d) spanning tree algorithm.
The LNW70 can also use electrical PTMs that are provisionable to support either 100BASE-T or 1000BASE-T traffic. The electrical
PTMs can occupy ports 1-4.
Prior to R7.0, the LNW70 could only occupy slot 1 of any Function
Unit group on the shelf (including Growth slots), and up to 20
1000BASE-X and 20 100BASE-LX ports were addressable when all
Function Unit groups are equipped with LNW70 circuit packs.
When DMX is equipped with VLF Main (LNW59) packs, Ethernet packs can occupy both Slot 1 and 2 of a Function or Growth Unit
(where applicable). With VLF Mains and all tributary slots populated with LNW70 packs, up to 40 1000BASE-X and 40 100BASE-LX ports are addressable.
Prior to Release 7.0 (and when VLF Mains are not used), if the LNW70 circuit packs occupy slot 1 of a Function Unit group, slot 2 must be populated with an apparatus blank.
Optical Specification
The LNW70 can utilize 1000BASE-LX, 1000BASE-SX, and
1000BASE-ZX PTM optics. The LNW70 can also utilize
100BASE-LX PTM optics for optical fast Ethernet. These PTM optics can be ordered and plugged into the LNW70 as their capacity becomes
needed. Refer to the sections entitled
1000BASE-LX Optical Ethernet/SAN
1000BASE-SX Optical Ethernet/SAN Specification
,
1000BASE-ZX Optical Ethernet/SAN Specification
for the detailed specifications of these optics.
...........................................................................................................................................................................................................................................................
1 0 - 1 0 2
365-372-300
Issue 8.0, September 2006
GbE (1000BASE-X)/ Fast-E (100BASE-LX/TX) Optical/Electrical
Ethernet (LNW70)
Technical Specifications
100Mb/GbE Electrical PTM for the LNW70 (R6.0)
The LNW70 now supports a dual function electrical PTM that is provisionable for 100 or 1000 Mbps traffic. It conforms to the
IEEE802.3 standards for 100BASE-T and 1000BASE-T in its respective settings (IEEE802.3z and IEE802.3ab). Connectivity is provided for an RJ-45 Cat 5 cable and the PTM has a maximum span length of 100 meters. Refer to the section entitled
100/1000BASE-TX (100/1000 Mbps) Ethernet (LNW63/64/70)
information on the electrical PTMs for the LNW70.
Performance monitoring
Performance monitoring capabilities are available on the LNW70 circuit packs. A detailed list of monitored parameters can be found in
Appendix B.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 0 - 1 0 3
Technical Specifications
FC-DATA: FICON/ESCON/Fibre-Channel (LNW73 and LNW73C)
SAN Transport Interface
............................................................................................................................................................................................................................................................
Description
The LNW73 and LNW73C (R6.0) are 4-port Storage Area Networking
(SAN) interface cards designed to facilitate SAN distance extensions via the DMX platform using GFP-T (ITU G.7041). These cards employ standard encapsulation according to ANSI T1X1.5/2000-024R4 (ITU
G.7041), and standard STS virtual concatenation according to ITU
G.707. For extended FC/FICON interfaces, the LNW73/73C also supports buffer_to_buffer credit management spoofing consistent with
ANSI T11 FC-BB-3_GFPT draft standard.
They utilize PTM optics to provide the option of FICON, ESCON, or
Fibre-channel interfaces natively on the DMX shelf. Each pack must be equipped to support only one type of traffic at a time (FICON/FC or
ESCON). The LNW73/73C can operate at 1 Gbps or 2 Gbps. When the pack is operating at 2 Gbps only every other port may be used. So, the total number of SAN interfaces on a DMX shelf is 20 (40 in 0x1) when the LNW73/73c is operating at 1G FC/FICON or ESCON, and 10 (20 in 0x1) when it is set to 2G FC/FICON.
While the capacity of each port is 2Gbps, the true capacity of each port is relative to the type of PTM it is equipped with. For ESCON traffic, the PTM ports have a capacity of 200 Mbps. The 2Gbps capacity of the ports is sufficient to support FC2G and FICON Express.
The LNW73C differs from the LNW73 in that it enables compression of asynchronous FC traffic. The LNW73C is able to conserve up to
50% of bandwidth versus uncompressed SAN traffic in typical applications. The R6.0 implementation of SAN compression enables a high throughput of up to two full-line rate FC-2G interfaces in a single pack.
Prior to R7.0, the LNW73/73c could only occupy slot 1 of any
Function Unit group on the shelf (including Growth slots). When DMX is equipped with VLF Main (LNW59) packs, FC-DATA packs can occupy both Slot 1 and 2 of a Function or Growth Unit (where applicable).
Prior to Release 7.0 (and when VLF Mains are not used), if the LNW70 circuit packs occupy slot 1 of a Function Unit group, slot 2 must be populated with an apparatus blank.
...........................................................................................................................................................................................................................................................
1 0 - 1 0 4
365-372-300
Issue 8.0, September 2006
FC-DATA: FICON/ESCON/Fibre-Channel (LNW73 and LNW73C)
SAN Transport Interface
Technical Specifications
Optical Specification
The LNW73 and LNW73C can utilize both 1000BASE-LX and
1000BASE-SX PTM optics. Both the 1000BASE-LX and
1000BASE-SX optics can support FICON traffic. The LNW73/73C can also utilize ESCON PTM optics for ESCON traffic. These PTM optics can be ordered and plugged into the LNW73/73C as their
capacity becomes needed. Refer to the sections entitled
Optical Ethernet/SAN Specification
1000BASE-SX Optical Ethernet/SAN
ESCON SAN Transport Specification (LNW73 and LNW73C)
for the detailed specifications of these
optics.
Performance monitoring
Performance monitoring capabilities are available on the LNW73/73C circuit packs. A detailed list of monitored parameters can be found in
Appendix B.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 0 - 1 0 5
Technical Specifications
10/100T (10/100BASE-T)/ Fast-E (100BASE-LX) Electrical/Optical
Ethernet Private Line (LNW74)
............................................................................................................................................................................................................................................................
Description
The LNW74 circuit packs provide sixteen 10/100BASE-TX, IEEE
802.3-compliant electrical interfaces (via the backplane of the shelf) that are capable of spanning distances of 100 meters. The LNW74 also provides 8 optical 100BASE-LX IEEE 802.3-compliant (100 Mbps) fast Ethernet interfaces. The LNW74 is a Private Line circuit pack.
The 10/100T interface function is full duplex mode and auto-negotiates speed (10/100 Mbps) when interfacing with other 802.3-compliant devices over twisted pair media. The LNW74 circuit pack must be housed in slot 1 of a Function Unit group and is not equipment protected. However, facility protection can be provided through the
WAN via SONET (UPSR, BLSR, or 1+1). The LNW74 also supports low- and high-order (STS/VT) VCAT.
Optical Specification
The LNW74 utilizes 100BASE-LX PTM optics. These PTM optics can be ordered and plugged into the LNW74 as their capacity becomes needed. Refer to the section entitled
and
specifications of these optics.
Performance monitoring
Performance monitoring capabilities are available on the LNW74 circuit packs. A detailed list of monitored parameters can be found in
Appendix B.
...........................................................................................................................................................................................................................................................
1 0 - 1 0 6
365-372-300
Issue 8.0, September 2006
Technical Specifications
RPR Enabled GbE (1000BASE-X)/ Fast-E (100BASE-LX/TX)
Optical Ethernet (LNW78)
............................................................................................................................................................................................................................................................
Description
This 8-port Ethernet interface provides 4-ports for short-reach and/or long-reach high-speed optical data transport at the rate of 1 Gb/s and
4-ports for optical 100BASE-LX transport at 100 Mbps. The first 4 ports (1-4) are for the GbE traffic (ports 3 and 4 are not available in
R7.0) and the second 4 ports (5-8) are for FE traffic. The LNW78 utilizes PTM optics, allowing you to equip additional ports as necessary. In R7.0, LNW78 adds support for the electrical
100/1000BASE-TX, electrical Ethernet PTM. This PTM may only occupy ports 1 and 2 of the pack. The LNW78 also supports similar port, switching, and traffic management capabilities as the LNW70.
The LNW78 supports standards compliant RPR switching per IEEE
802.17. LNW78 will support one RPR instance in R6.0 and two in the future. The LNW78 provides two internal Virtual Concatenation Group
(VCG) WAN ports (will support 4 in the future) with a total capacity of
2.5 Gbps capacity for Ethernet RPR traffic (24 STS-1s in each direction).
Beginning in R7.0, VCG ports 17-22 available to provide EoS connectivity. This feature allows EoS port connectivity to RPR ring interfaces via the faceplate of the LNW78 and/or hairpin cross-connects. Interconnection of multiple RPR rings on the same shelf or separate shelf using EoS VCGs is also supported. Finally, EoS traffic can be managed with QoS support on EoS VCGs.
Prior to R7.0, LNW78 packs could only be placed in Slot 1 of any function group or growth slot in the shelf (A1-G1) and DMX supported a total add/drop capacity of 10 RPR GbE ports and 20 RPR FE ports if all slots were equipped with LNW78 circuit packs.
Beginning in R7.0, with the use of true 0x1 and the LNW59 VLF Main,
LNW78 can occupy slots 1 and 2 of a Function or Growth group. This can increase the overall capacity of the system to 20 RPR GbE (optical only) ports and 20 RPR FE (optical only) ports per shelf.
Prior to Release 7.0 (and when VLF Mains are not used), if the LNW78 circuit packs occupy slot 1 of a Function Unit group, slot 2 must be populated with an apparatus blank.
Optical Specification
The LNW78 can utilize both 1000BASE-LX and 1000BASE-SX PTM optics. The LNW78 can also utilize 100BASE-LX PTM optics for
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 0 - 1 0 7
RPR Enabled GbE (1000BASE-X)/ Fast-E (100BASE-LX/TX)
Optical Ethernet (LNW78)
Technical Specifications
optical fast Ethernet. These PTM optics can be ordered and plugged into the LNW78 as their capacity becomes needed. Refer to the sections entitled
1000BASE-LX Optical Ethernet/SAN Specification
1000BASE-SX Optical Ethernet/SAN Specification
for the detailed specifications of these optics.
Performance monitoring
Performance monitoring capabilities are available on the LNW78 circuit packs. A detailed list of monitored parameters can be found in
Appendix B.
...........................................................................................................................................................................................................................................................
1 0 - 1 0 8
365-372-300
Issue 8.0, September 2006
Technical Specifications
Allowed PTM Tranceivers
............................................................................................................................................................................................................................................................
Overview
DMX utilizes Pluggable Transmission Module (PTM), also known as
SFP, transceivers on the LNW63, LNW64, LNW70, LNW73/73C,
LNW74, and LNW78 circuit packs. To ensure proper optical performance, mechanical fit, compliance with EMC, and compliance with laser safety standards, the Lucent specified PTM transceivers listed in the table below must be used.
Only the Lucent specified PTM transceivers listed below are compatible with DMX software. If non-Lucent specified PTM transceivers are installed in DMX, the system will reject that transceiver, and that optical port (or electrical in the case of the
BASE-T-C1) will become inoperable (until approved parts are installed).
Allowed Optics
The table below lists the PTM transceivers that may be used in the
LNW63, LNW64, LNW70, LNW73/73C, LNW74, and LNW78 circuit packs.
Table 10-61 PTM Optics for LNW63/64/70/73/73C/74/78
Apparatus Code
100BASE-LX-I1
(FE-TX)
GE-1X2XFC-SX-C1
(1000BASE-SX,
1Gbps and 2 Gbps
Fibre-Channel)
GE-1X2XFC-LX-C1
(1000BASE-LX,
1Gbps and 2 Gbps
Fibre-Channel/FICON)
Comcode
109527812
109527796
109527804
Description
Optical Fast Ethernet PTM,
LC-type connectors (FE-1310SM), OSP hardened. Specification:
GbE short-reach, Single-Mode PTM, supports
Ethernet and Fibre-Channel traffic, LC-type connectors (GbE/FC/2FC-850)
Specification:
GbE long-reach, Single-Mode PTM, supports
Ethernet, FICON, and Fibre-Channel traffic,
LC-type connectors (GbE/FC/2FC-1310):
Specification:
Used In
LNW74/70/
78
LNW70/73/
73C/78
LNW70/73/
73C/78
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 0 - 1 0 9
Allowed PTM Tranceivers
Technical Specifications
Apparatus Code
GE-1X2XFC-SX-I1
(1000BASE-SX,
1Gbps)
GE-1X2XFC-LX-I1
(1000BASE-LX,
1Gbps)
1000BASE-ZX-I1
(1000BASE-ZX,
1Gbps)
BASE-T-C1
FE and GbE (electrical-
NOT OSP)
ESCON-MM-I1
(ESCON)
Comcode
109570606
109568782
109541862
109565549
109523886
Description
GbE short-reach, Single-Mode PTM, supports
Ethernet and Fibre-Channel traffic, LC-type connectors, OSP hardened,
(GbE/FC/2FC-850). Specification:
1000BASE-SX Optical Ethernet/SAN
GbE long-reach, Single-Mode PTM, supports
Ethernet, FICON, and Fibre-Channel traffic,
LC-type connectors, OSP hardened
(GbE/FC/2FC-1310)
Specification:
GbE long-reach, Single-Mode PTM, supports
Ethernet, LC-type connectors, and is OSP hardened, (GbE-1550). Specification:
1000BASE-ZX Optical Ethernet/SAN
Electrical PTM, provisionable to 100 or 1000
Mbps, Lucent Approved
RJ-45 Cat 5-E cable, maximum span length of 100 meters
LC-type connectors (ESCON-1310),
Specification:
Specification (LNW73 and LNW73C)
Used In
LNW63/64/
70/73/73C
LNW63/64/
70/73/73C
LNW63/64/
70/73/73C/
78
LNW63/64/
70
LNW73/73C
Note:
In the columns titled “Apparatus Codes”, notice that each code ends in
either I1 or C1. These characters denote the operating environment the tranceiver is approved for. The characters I1 following an apparatus code mean that tranceiver is approved for OSP deployments. C1 means the tranceiver is approved for CO deployments.
...........................................................................................................................................................................................................................................................
1 0 - 1 1 0
365-372-300
Issue 8.0, September 2006
Technical Specifications
1000BASE-SX Optical Ethernet/SAN Specification
............................................................................................................................................................................................................................................................
Overview
The 1000BASE-SX PTMs can be used for Gigabit Ethernet,
Fibre-Channel, and FICON service over Multi-Mode Fiber (MMF).
System specifications
The following are the 1000BASE-SX system specifications:
• Optical Line Rate: 1.25 Gb/s +/- 100 ppm
• Optical Line Coding: 8B/10B
• Performance: Short-reach.
GbE/FC/2XFC Compliance
The PTM optics are compliant with GbE, FC, and 2XFC specifications.
Operating range
The table below shows the operating range for the 1000BASE-SX optical Ethernet/SAN interface. A 1000BASE-SX compliant transceiver supports both 50
µ m and 62.5
µ m fiber media types. A transceiver that exceeds the operational range requirement while meeting all other optical specifications is considered compliant (e.g., a
50
µ m solution operating at 600 m meets the minimum range requirement of 2 to 550 m).
Table 10-62 1000BASE-SX Operating Range Over Each Optical
Fiber Type
Fiber Type
62.5
62.5
µ m MMF
50
µ m MMF
50
10
µ m MMF
µ m MMF
µ m SMF
Modal Bandwidth @ 850 nm
(minimum overfilled launch)
(MHz-km)
160
200
400
500
Not supported
Minimum Range
(meters)
2 to 220
2 to 275
2 to 500
2 to 550
Not supported
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 0 - 1 1 1
1000BASE-SX Optical Ethernet/SAN Specification
Technical Specifications
Transmitter specifications
The 1000BASE-SX optical transmitter meets the specifications defined in IEEE 802.3. The table below shows some of the 1000BASE-SX optical transmitter specifications. Measurement techniques are defined in IEEE 802.3, Section 38, Clause 6.
The 1000BASE-SX transceiver also meets ANSI INCITS FC-PI standards for FC and 2xFC traffic (352-2002).
Table 10-63 1000BASE-SX Transmit Specifications
Description
Transmitter type
Signaling speed (range)
Wavelength (
T
T rise
/T
λ
, range) fall
(max; 20%-80%; l > 830 nm) rise
/T fall
(max; 20%-80%; l < 830 nm)
RMS spectral width (max)
62.5/50
µ
m MMF
Shortwave Laser
1.25 +/- 100 ppm
770 to 860
0.26
0.21
0.85
0 (Note 1)
-9.5
Average launch power (max)
Average launch power (min)
Average launch power of OFF transmitter
(max)
(Note 2)
Extinction ratio (min)
-30
9
RIN (max) -117
Coupled Power Ratio (CPR) (min)
(Note 3)
9 < CPR
Unit
GBd nm ns ns nm dBm dBm dBm dB dB/Hz dB
Table notes
1.The 1000BASE-SX launch power shall be the lesser of the class 1 safety limit as defined by IEEE 802.3, Section 38, Clause 7.2 or the
average receiver power (maximum) defined by Table 10-64 below.
2.Examples of an OFF transmitter are as follows: no power supplied to the optical module, laser shutdown for safety conditions, and activation of a “transmit disable” or other optional module laser shut-down conditions.
3.Radial overfilled launches (described in IEEE 802.3, Section 38A,
Clause 2) should be avoided even if they meet CPR ranges.
...........................................................................................................................................................................................................................................................
1 0 - 1 1 2
365-372-300
Issue 8.0, September 2006
1000BASE-SX Optical Ethernet/SAN Specification
Technical Specifications
Receiver specifications
The 1000BASE-SX optical receiver meets the specifications defined in
IEEE802.3, Section 38.3.2. The table below shows some of the
1000BASE-SX optical receiver specifications. Measurement techniques are defined in IEEE802.3, Section 38, Clause 6.
Table 10-64 1000BASE-SX Receive Specifications
Description
Signaling speed (range)
Wavelength (range)
Average receive power (max)
Receive sensitivity
Return loss (min)
Receive electrical 3 dB upper cutoff frequency (max)
62.5
µ
m MMF
1.25 +/- 100 ppm
770 to 860
0
-17
12
1500
50
µ
m MMF
1.25 +/- 100 ppm
770 to 860
0
-17
12
1500
Unit
GBd nm dBm dBm dB
MHz
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 0 - 1 1 3
1000BASE-SX Optical Ethernet/SAN Specification
Technical Specifications
Parameter
Link budgets
The worst-case power budget and link penalties for a 1000BASE-SX channel are shown in the table below.
Table 10-65 1000BASE-SX Link Budgets and Penalties
62.5
µ
m MMF 50
µ
m MMF Unit
Modal bandwidth as measured at
850 nm (minimum, overfilled launch)
Link power budget
Operating distance
Channel insertion loss
(Note 1)
Link power penalties
(Note 1)
Unallocated margin in link power budget
(Note 2)
160
7.5
220
2.38
4.27
0.84
200
7.5
275
2.60
4.29
0.60
400
7.5
500
3.37
4.07
0.05
500
7.5
550
3.56
3.57
0.37
MHz-km dB m dB dB dB
Table notes
1. A wavelength of 830 nm is used to calculate the channel insertion loss, link power penalties, and unallocated margin.
...........................................................................................................................................................................................................................................................
1 0 - 1 1 4
365-372-300
Issue 8.0, September 2006
1000BASE-SX Optical Ethernet/SAN Specification
Technical Specifications
Format specification
The 1000BASE-SX Ethernet/SAN interface complies with the following formatting standards:
•
Maximum frame size refer to Packet size in different tagging modes (A-86)
• standard IEEE 802.1Q VLANs
• Ethernet to SONET Mapping, (G.7041 (GFP) and G.707 (Virtual
Concatenation)
• Protection (SONET and/or 802.1W) and Ethernet Bridging
(802.1D)
Performance monitoring
Performance monitoring capabilities are available on the
1000BASE-SX interface. A detailed list of monitored parameters can be found in Appendix B.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 0 - 1 1 5
Technical Specifications
1000BASE-LX Optical Ethernet/SAN Specification
............................................................................................................................................................................................................................................................
Overview
The 1000BASE-LX PTMs can be used for GbE, 1Gbps and 2 Gbps
Fibre-Channel, and FICON service over Single-Mode Fiber (SMF).
System specifications
The following are the 1000BASE-LX system specifications:
• Optical Line Rate: 1.25 Gb/s +/- 100 ppm
• Optical Line Coding: 8B/10B
• Performance: Long-reach.
GbE/FC/2XFC/FICON
Compliance
The PTM optics are compliant with GbE, FC, and 2XFC specifications; and compatible with FICON specifications.
Operating range
The table below shows the operating range for the 1000BASE-LX optical Ethernet interface.
Table 10-66 1000BASE-LX Operating Range
Fiber Type
10
µ m SMF
Minimum Range (meters)
2 to 10,000
...........................................................................................................................................................................................................................................................
1 0 - 1 1 6
365-372-300
Issue 8.0, September 2006
1000BASE-LX Optical Ethernet/SAN Specification
Technical Specifications
Transmitter specifications
The optical 1000BASE-LX optical transmitter meets the specifications defined in IEEE802.3. The table below shows some of the
1000BASE-LX optical transmitter specifications.
The 1000BASE-LX transceiver also meets ANSI INCITS FC-PI standards for FC and 2xFC traffic (352-2002).
Table 10-67 1000BASE-LX Transmit Specifications
Description
Transmitter type
Signaling speed (range)
Wavelength (l, range)
T rise
/T fall
(max; 20%-80% response time)
RMS spectral width (max)
10
µ
m SMF
Longwave Laser
Unit
1.25 +/- 100 ppm GBd
1270 to 1355 nm
0.26
4 ns nm
Average launch power (max)
Average launch power (min)
-3
-11.0
Average launch power of OFF transmitter (max) -30
RIN (max) -120 dBm dBm dBm dB/Hz
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 0 - 1 1 7
1000BASE-LX Optical Ethernet/SAN Specification
Technical Specifications
Receiver specifications
The 1000BASE-LX receiver meets the specifications defined in IEEE
802.3. The table below shows some of the 1000BASE-LX optical receiver specifications.
Table 10-68 1000BASE-LX Receive Specifications
Description
Signaling speed (range)
Wavelength (range)
Average receive power (max)
Receive sensitivity
Return loss (min)
Receive electrical 3 dB upper cutoff frequency (max)
10
µ
m SMF
1.25 +/- 100 ppm
1270 to 1355
-3
-19
12
1500
Unit
GBd nm dBm dBm dB
MHz
...........................................................................................................................................................................................................................................................
1 0 - 1 1 8
365-372-300
Issue 8.0, September 2006
1000BASE-LX Optical Ethernet/SAN Specification
Technical Specifications
Link budgets
The worst-case power budget and link penalties for a 1000BASE-LX channel are shown in the table below.
Table 10-69 1000BASE-LX Link Budgets and Penalties
Parameter
Link power budget
Operating distance
Allocation for link penalties
(Note 1)
10
µ
m SMF Unit
8.0
dB
10,000
2.0
m dB
Table notes
1.A wavelength of 1270 nm is used to calculate the link penalty.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 0 - 1 1 9
1000BASE-LX Optical Ethernet/SAN Specification
Technical Specifications
Format specification
The 1000BASE-LX Ethernet/SAN interface complies with the following formatting standards:
•
Maximum frame size refer to Packet size in different tagging modes (A-86)
• standard IEEE 802.1Q VLANs
• Ethernet to SONET Mapping, (G.7041 (GFP) and G.707 (Virtual
Concatenation))
• Protection (SONET and/or 802.1W) and Ethernet Bridging
(802.1D)
Performance monitoring
Performance monitoring capabilities are available on the
1000BASE-LX interface. A detailed list of monitored parameters can be found in Appendix B.
...........................................................................................................................................................................................................................................................
1 0 - 1 2 0
365-372-300
Issue 8.0, September 2006
Technical Specifications
1000BASE-ZX Optical Ethernet/SAN Specification
............................................................................................................................................................................................................................................................
Overview
The 1000BASE-ZX PTMs can be used for GbE service over
Single-Mode Fiber (SMF). The 1000BASE-ZX PTMs are OSP hardened for outside plant applications.
System specifications
The following are the 1000BASE-ZX system specifications:
• Optical Line Rate: 1.25 Gb/s +/- 100 ppm
• Optical Line Coding: 8B/10B
• Performance: Long-reach (80 km).
Operating range
The table below shows the operating range for the 1000BASE-ZX optical Ethernet interface.
Table 10-70 1000BASE-ZX Operating Range
Fiber Type
10
µ m SMF
Minimum Range (meters)
2 to 80,000
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 0 - 1 2 1
1000BASE-ZX Optical Ethernet/SAN Specification
Technical Specifications
Transmitter specifications
The 1000BASE-ZX optical transmitter meets the specifications defined in IEEE802.3. The table below shows some of the 1000BASE-ZX optical transmitter specifications.
Table 10-71 1000BASE-ZX Transmit Specifications
Description
Transmitter type
10
µ
m SMF
Longwave Laser
Unit
Signaling speed (range)
Wavelength (l, range)
T rise
/T fall
(max; 20%-80% response time)
Maximum Spectral Width
(
∆λ
20
)
Average launch power (max) +5
Average launch power (min) 0
Average launch power of OFF transmitter (max) -40
RIN (max) -120
1.25 +/- 100 ppm GBd
1500 to 1580 nm
0.26
1 ns nm dBm dBm dBm dB/Hz
...........................................................................................................................................................................................................................................................
1 0 - 1 2 2
365-372-300
Issue 8.0, September 2006
1000BASE-ZX Optical Ethernet/SAN Specification
Technical Specifications
Receiver specifications
The 1000BASE-ZX receiver meets the specifications defined in the table below.
Table 10-72 1000BASE-ZX Receive Specifications
Description
Signaling speed (range)
Wavelength (range)
Average receive power (max)
Receive sensitivity
Return loss (min)
10
µ
m SMF
1.25 +/- 100 ppm
1500 to 1580
0
-22.5
12
Unit
GBd nm dBm dBm dB
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 0 - 1 2 3
1000BASE-ZX Optical Ethernet/SAN Specification
Technical Specifications
Link budgets
The worst-case power budget and link penalties for a 1000BASE-ZX channel are shown in the table below.
Table 10-73 1000BASE-ZX Link Budgets and Penalties
Parameter
Maximum Channel Insertion Loss
Minimum Channel Insertion Loss
Maximum Dispersion
Optical Path Penalty
10
µ
m SMF Unit
21.0
dB
5.0
1600
1.5
dB ps/nm dB
...........................................................................................................................................................................................................................................................
1 0 - 1 2 4
365-372-300
Issue 8.0, September 2006
1000BASE-ZX Optical Ethernet/SAN Specification
Technical Specifications
Format specification
The 1000BASE-ZX Ethernet/SAN interface complies with the following formatting standards:
• standard IEEE 802.1Q VLANs
• Ethernet to SONET Mapping, (G.7041 (GFP) and G.707 (Virtual
Concatenation))
• Protection (SONET and/or 802.1W) and Ethernet Bridging
(802.1D)
Performance monitoring
Performance monitoring capabilities are available on the
1000BASE-ZX interface. A detailed list of monitored parameters can be found in Appendix B.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 0 - 1 2 5
Technical Specifications
100BASE-LX Optical Ethernet Specification
............................................................................................................................................................................................................................................................
Overview
The 100BASE-LX PTMs can be used on the LNW70 and LNW74.
System specifications
The following are the 100BASE-LX system specifications:
• Optical Line Rate: 125 MBd+/- 50 ppm
• Optical Line Coding: 4B/5B
• Performance: Long-reach.
Operating range
The table below shows the operating range for the 100BASE-LX optical Ethernet interface. A 100BASE-LX compliant transceiver supports 10
µ m fiber media types.
Table 10-74 100BASE-LX Operating Range Single-Mode Fiber
Fiber Type
10
µ m SMF
Minimum Range (meters)
2 to 10,000
Transmitter specifications
The 100BASE-LX transmitter meets these specifications defined in
IEEE 802.3. The table below describes some of the transmit specifications for 100BASE-LX.
Table 10-75 100BASE-LX Transmit Specifications
Description
Transmitter type
Signaling speed (range)
Wavelength (range)
T rise
/T fall
(max; 20%-80% response time)
RMS spectral width (max)
Average launch power (max)
Average launch power (min)
Average launch power of OFF transmitter
(max)
Extinction ratio (min)
10
µ
m SMF
Longwave Laser
-8
-15
-45
125 +/- 50 ppm
1260 to 1360
3.5
7.7
5
Unit
dB
MBd nm ns nm dBm dBm dBm
...........................................................................................................................................................................................................................................................
1 0 - 1 2 6
365-372-300
Issue 8.0, September 2006
100BASE-LX Optical Ethernet Specification
Technical Specifications
Receiver specifications
The 100BASE-LX receiver meets these specifications defined in IEEE
802.3. The table below describes some of the receiver specifications for
100BASE-LX.
Table 10-76 100BASE-LX Receive Specifications
Description
Signaling speed (range)
Wavelength (range)
Average receive power (max)
Receive sensitivity
10
µ
m SMF
125 +/- 50 ppm
1260 to 1360
-8
-25
Unit
MBd nm dBm dBm
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 0 - 1 2 7
100BASE-LX Optical Ethernet Specification
Technical Specifications
Link budgets
The worst-case power budget and link penalties for a 100BASE-LX channel are shown in the table below.
Table 10-77 100BASE-LX Link Budgets and Penalties
Parameter
Link power budget
Operating distance
Allocation for link penalties (Note 1)
10
µ
m
SMF
10
10,000
4.0
Unit
dB m dB
Table notes
1. A wavelength of 1270 nm is used to calculate the link penalty allocation.
...........................................................................................................................................................................................................................................................
1 0 - 1 2 8
365-372-300
Issue 8.0, September 2006
100BASE-LX Optical Ethernet Specification
Technical Specifications
Format specification
The 100BASE-LX Ethernet interface complies with the following formatting standards:
• standard IEEE 802.1Q VLANs
• Ethernet to SONET Mapping, (G.7041 (GFP) and G.707 (Virtual
Concatenation))
• Protection (SONET and/or 802.1W) and Ethernet Bridging
(802.1D)
Performance monitoring
Performance monitoring capabilities are available on the 100BASE-LX interface. A detailed list of monitored parameters can be found in
Appendix B.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 0 - 1 2 9
Technical Specifications
ESCON SAN Transport Specification (LNW73 and LNW73C)
............................................................................................................................................................................................................................................................
ESCON Specifications
The following are the ESCON system specifications for the
LNW73/73C:
• Optical Line Rate: 200 MBd
• Optical Line Coding: 8B/10B
• Performance: Short-reach.
Operating range
The table below shows the operating range for the ESCON optical
SAN interface. The ESCON transceiver supports 62.5 and 50
µ m multi-mode fiber media types.
Table 10-78 ESCON Optics Operating Range Multi-Mode Fiber
Fiber Type
62.5
µ m MMF
50
µ m MMF
Range
3 km
2 km
Transmitter specifications
The ESCON transmitter conforms to the IBM Corporation
SA23-0394-03 standard. The table below describes some of the transmit specifications for ESCON transmitter.
Table 10-79 ESCON Transmit Specifications
Description
Transmitter type
Signaling speed (range)
Wavelength (range)
T rise
/T fall
(max; 20%-80% response time)
RMS spectral width (max)
Average launch power (max)
Average launch power (min)
Extinction ratio (min)
62.5/50
µ
m MMF
LED
200 +/- 0.04
1280 to 1380
1.7
175
-14
-20.5
8
Unit
Mb/s nm ns nm dBm dBm dB
...........................................................................................................................................................................................................................................................
1 0 - 1 3 0
365-372-300
Issue 8.0, September 2006
ESCON SAN Transport Specification (LNW73 and LNW73C)
Technical Specifications
Receiver specifications
The ESCON receiver conforms to the IBM Corporation SA23-0394-03 standard. The table below describes some of the receive specifications for ESCON receiver.
Table 10-80 ESCON Receive Specifications
Description
Signaling speed (range)
Average receive power (max)
Receive sensitivity
62.5/50
µ
m MMF
200 +/- 0.04
-14.5
-29
Unit
Mb/s dBm dBm
Link budgets
The worst-case power budget and link penalties for an ESCON channel are shown in the table below.
Table 10-81 ESCON Maximum Link Loss
Parameter
Link power budget
62.5
µ
m
SMF
50
µ
m
SMF
Unit
8.0
8.0
dB
3 2 km
Format specification
The LNW73/73C interface complies with the following formatting standards:
• The LNW73/73C supports 4 VCGs with a capacity of 48 STS-1s
• FICON/ESCON/FC to SONET Mapping, (G.7041 and G.707
(Virtual Concatenation)), SA22-7202-02, SA23-0394-03, IBM
SG24-4662-00, ANSI X3.296-1977
• Protection SONET BLSR and UPSR (split routing available with
BLSR)
Performance monitoring
Performance monitoring capabilities are supported on the
FICON/ESCON/Fibre-channel interfaces. A detailed list of monitored parameters can be found in Appendix B.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 0 - 1 3 1
Technical Specifications
System Performance
Overview
............................................................................................................................................................................................................................................................
Purpose
This section provides performance specifications for the DMX Access
Multiplexer.
Contents
The following performance specifications are discussed in this section:
...........................................................................................................................................................................................................................................................
1 0 - 1 3 2
365-372-300
Issue 8.0, September 2006
Technical Specifications
SONET Overhead Bytes
............................................................................................................................................................................................................................................................
Overview
DMX uses SONET transport and path overhead bytes as specified in
GR-253-CORE.
V4 byte
The reserved V4 byte in the VT1.5 superframe is sometimes used for internal error detection in a DMX shelf. This internal usage of the V4 byte may cause the value of a transmitted V4 byte to vary. The DMX always ignores the value of the V4 byte received from another network element as required by GR-253-CORE.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 0 - 1 3 3
Technical Specifications
Wander/Jitter
............................................................................................................................................................................................................................................................
Maximum time interval error (MTIE)
For SONET optical interfaces, the maximum time interval error
(MTIE) does not exceed 60 nanoseconds phase variation when timed with a wander-free reference.
Wander requirements
Wander transfer, tolerance, and generation requirements are met as specified in GR-253-CORE.
Jitter requirements
Jitter transfer, tolerance, and generation requirements are met as specified in GR-253-CORE and GR-499-CORE.
Short-term stability
The SONET interfaces meet the T1.101 OC-N output short-term stability mask as specified in GR-253-CORE, Section 5.
...........................................................................................................................................................................................................................................................
1 0 - 1 3 4
365-372-300
Issue 8.0, September 2006
Technical Specifications
Signal Performance
............................................................................................................................................................................................................................................................
Overview
The following specifications apply to the standard networks defined in
GR-499-CORE, Issue 3.
DS1 rate
For systems interfacing at the DS1 rate, the number of errored seconds during a 7-hour, one-way loopback test, is less than 10.
DS3 rate
BER
For systems interfacing at the DS3 rate, the number of errored seconds during a 2-hour, one-way loopback test, is less than 29.
The BER is less than 2x10
-10 for both the DS1 and DS3 rates.
Burst-errored seconds are excluded.
Burst-errored seconds
The frequency of burst-errored seconds, other than those caused by protection switching induced by hard equipment failures, averages less than 4 per day.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 0 - 1 3 5
Technical Specifications
Synchronization
............................................................................................................................................................................................................................................................
Overview
The embedded Stratum 3 Timing Generator meets the specifications of
GR-253-CORE, SONET Transport Systems Generic Criteria. The timing generator function is embedded in the 1x1 protected optical interface circuit packs in the main slot pair.
Timing modes
The timing generator supports four timing modes:
•
External timing
Locked to an external Stratum 3 (+/- 4.6 ppm) or better DS1/E1 reference.
•
Line timing
Locked to recovered clock from an OC-N signal (from Main or tributary OC-3/OC-12/OC-48/OC-192).
•
Free running
Timing derived from high-stability temperature-compensated voltage-controlled crystal oscillator (TCVCXO) with a long-term accuracy of +/- 4.6 ppm and temperature stability of -40 o
C to
+65 o
C.
•
Holdover
Timing derived from the internal oscillator in the case of an unprotected synchronization reference failure. In this instance, the
Stratum Timing Generator switches to “holdover mode” and continues to provide system timing, using the internal oscillator to maintain the last known good reference frequency. If the DS1/E1 timing output is enabled for network synchronization, DS1/E1
AIS will be inserted on detection of unprotected optical reference failure. In holdover mode, the accuracy is +/-.37 ppm over the full
-40 to +65 o
C temperature range.
•
DS1/E1 timing outputs
In addition, each timing generator (main circuit pack) provides a single DS1 or E1 sync output derived from a received optical interface signal (OC-N). These DS1/E1 timing outputs may be used to provide a timing reference signal to a local BITS clock
(see Chapter 5 of this document).
...........................................................................................................................................................................................................................................................
1 0 - 1 3 6
365-372-300
Issue 8.0, September 2006
Synchronization
Technical Specifications
DS1 timing functions
The DS1 timing reference inputs and outputs meet the specifications of
GR-499-CORE for DS1 interfaces and GR-253-CORE for timing references. The following are the DS1 timing functions:
• Two DS1 timing reference inputs
• Two DS1 timing reference outputs
• Software-provisionable line build-outs for DS1 timing outputs (up to 655 feet depending on cable type)
• Alarms (Out of Frame, AIS, BER).
E1 timing functions
The E1 timing reference inputs and outputs meet the specifications of
ITU-T G.813 for frequency accuracy, pull-in, hold-in and pull-out ranges, wander, jitter, noise tolerance, noise transfer, transient response and holdover performance. E1 references also comply with ITU-T
G.704 standards for SDN SSM. The following are the E1 timing functions:
• Two E1 timing reference inputs
• Two E1 timing reference outputs
• Software-provisionable line build-outs for E1 timing outputs (up to 655 feet depending on cable type)
• Alarms (Out of Frame, AIS, BER).
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 0 - 1 3 7
Technical Specifications
Protection Switching
............................................................................................................................................................................................................................................................
1+1 networks
DMX complies with SONET 1+1 unidirectional and bidirectional revertive and nonrevertive protection switching requirements as specified in GR-253-CORE. Automatic line switches are initiated by signal fail and signal degrade conditions on the received low-speed
(OC-3/12/48) or high-speed (OC-12/48/192) optical signal and are completed within 50 milliseconds of a signal failure. The signal’s BER is calculated from violations of the SONET line overhead B2 parity bytes. Signal fail is declared for incoming LOS, LOF, line AIS, or BER exceeding a provisionable 10
-3
to 10
-5
threshold, while a BER exceeding a provisionable 10
-5
to 10
-9
threshold causes the signal degrade condition. Manual switch commands are available through the local and remote operations interfaces.
Important!
DMX now supports Bidirectional Optimized 1+1
Linear Protection Switching per ITU-T G.841 Annex B.
Bidirectional optimized 1+1 is designed to enable interoperability between DMX and SDH equipment. It is a separate switching scheme from standard 1+1 bidirectional and does not work with standard 1+1.
DMX also supports non-revertive bidirectional 1+1 switching to enable interworking between DMX and Ciena Core Director.
High-speed UPSR networks
Path protection rings feed a SONET payload (STS or virtual tributary
[VT]) from the ring entry point, simultaneously in both rotations of the ring, to the signal’s ring exit point. The node that terminates the signal from the ring monitors both ring rotations and is responsible for selecting the signal that has the highest quality based on LOS, LOF, and path BER performance. On pass-through paths, all detected hard failures (LOS, LOF, line AIS, or STS-1 path AIS) result in VT AIS insertion in the outgoing signals. This allows the terminating node to be aware of the failure and to switch to protection. Protection switching is completed within 50 milliseconds of failure detection.
Under normal conditions, both incoming SONET path signals to the switch selection point are of high quality, and the signal can be selected from either ring. A failure or transmission degradation on one of the rings requires that the other ring path be selected. The DMX provides nonrevertive switching. When and if the critical service should revert to a particular ring, a manual path protection switching command allows
...........................................................................................................................................................................................................................................................
1 0 - 1 3 8
365-372-300
Issue 8.0, September 2006
Protection Switching
Technical Specifications
switching back to the original path for ease of ring maintenance in non-revertive applications.
Low-speed UPSR networks
On low-speed SONET optical interfaces (OC-3/12/48), UPSR is optional and protection switching is provisionable (UPSR or 1+1) on a per-line basis.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 0 - 1 3 9
Technical Specifications
Transient Performance
............................................................................................................................................................................................................................................................
Power loss restart
After system shutdown due to power loss, the system will exhibit a
2-second error free transmission interval which begins within 5 minutes of restoration of power.
Transmission start-up on signal application
The system, after having no signal applied for greater than 1 minute at the DSX-n interface, will exhibit a 2-second error free transmission interval which begins within 5 seconds of the reapplication of a signal.
...........................................................................................................................................................................................................................................................
1 0 - 1 4 0
365-372-300
Issue 8.0, September 2006
Technical Specifications
Transmission Delay
............................................................................................................................................................................................................................................................
One-way transmission delay
The table below, lists the worst-case measured one-way transmission delay (microseconds) between DMX interfaces.
Table 10-82 Transmission Delay in Microseconds
Interface
Cross-Connect
OC-n
EC-1
DS1
DS3
OC-n EC1
STS-n VT VT
50 25 50
50
100
N/A
25
100
25
-
-
-
STS-1
-
-
-
25
DS1
VT
-
-
-
100
STS-1
-
-
-
100
DS3
STS-1
-
-
-
25
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 0 - 1 4 1
Technical Specifications
Performance Monitoring
............................................................................................................................................................................................................................................................
Overview
DMX performance monitoring complies with GR-253-CORE and
ANSI T1.231-1997 specifications for SONET and asynchronous networks.
SONET PM parameters
For information concerning PM parameters and all other PM capabilities associated with DMX please refer to Appendix B of this document.
Ethernet parameters
DMX provides PM capabilities for the 10/100T, 100BASE-LX,
1000BASE-SX, and 1000BASE-LX Ethernet interfaces as well as the
FICON/FC and ESCON interfaces. PM data is collected at each LAN and WAN interface in the network for both incoming and outgoing directions and is stored in quarter-hour and day bins. The WAN interface provides a connection to a SONET Virtual Concatenation
Group (VCG).
Provisionable threshold crossing alerts (TCAs) are supported on the
Ethernet interfaces. PM parameters that provide PM data on all
Ethernet interfaces can be found in Appendix B of this document.
...........................................................................................................................................................................................................................................................
1 0 - 1 4 2
365-372-300
Issue 8.0, September 2006
Technical Specifications
Operations Interfaces
Overview
............................................................................................................................................................................................................................................................
Purpose
This section presents the operation interfaces that are required to support technician access to the system and allow alarms and status information generated by the system to be reported. The operation interfaces include the CIT interface, IAO LAN (via OSI or TCP/IP),
SYSCTL faceplate LEDs, and equipment indicators. DMX supports office alarms, user-definable miscellaneous discretes, and TL1.
Contents
The following operation interfaces are discussed in this section:
Craft Interface Terminal (PC-CIT)
Personal Computer Specifications for Software Download
LEDs, Indicators, and Office Alarms
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 0 - 1 4 3
Technical Specifications
Craft Interface Terminal (PC-CIT)
............................................................................................................................................................................................................................................................
Overview
The DMX PC-CIT is the primary tool used to interface with the DMX.
It is a personal computer (PC) with the DMX user-interface software installed. The DMX PC-CIT is compatible with PCs running Microsoft
Windows XP, Windows NT and Windows 2000. The PC-CIT also provides a user-friendly TL1 command builder interface.
Minimum requirements
It is anticipated that most customers will dedicate a lap-top PC to run the DMX PC-CIT applications software. However, a properly configured desktop PC will also suffice.
The following list shows the minimum requirements for the customer-provided PC with recommended Windows operating system.
• Microsoft Windows XP, 2000 or NT 4.0 Operating System with service pack 4. The customer is responsible for ensuring that the
PC remains virus -free.
• Pentium 266 MHz processor; Pentium III 500 MHz processor is recommended for optimum performance
• 128 MB RAM minimum: 256 MB RAM minimum for 5 system view
• One-gigabyte hard-disk drive with at least 150 megabytes of free space. The DMX PC-CIT application requires 50 MB, and the installation requires 30MB. In addition, each copy of the NE generic requires an additional 60 MB.
• CD-ROM drive
• SVGA monitor 800x 600 resolution (1024 x 768 recommended)
• 10 BASE-T LAN interface
Pin Designations/signals are:
– -1 TD+
– -2 TD-
– -3 RD+
– -6 RD-
...........................................................................................................................................................................................................................................................
1 0 - 1 4 4
365-372-300
Issue 8.0, September 2006
Craft Interface Terminal (PC-CIT)
Technical Specifications
PC-CIT and Windows requirements
The following table illustrates the Windows operating system requirements for DMX PC-CITs.
DMX port/
Windows
Guidelines
Windows XP
Windows NT
Windows 98 and 2000
Serial Port
X
X
X
OSI/TCP-IP LAN
Port
X
X
X
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 0 - 1 4 5
Technical Specifications
TL1/LAN
............................................................................................................................................................................................................................................................
Overview
DMX supports a TL1 over TCP/IP interface or TL1 over OSI LAN interface for communication between a DMX NE and an Element
Management System (EMS) of a Network Management System
(NMS). TL1 over TCP/IP LAN complies with requirements specified in IEEE 802.3 and NSIF-AR-9806-088R11.
TL1 translation device
(T-TD Gateway)
The T-TD is a device that translates TL1 messages over a TCP/IP connection to a TL1 over OSI association, providing a TL1 TCP-OSI gateway. The T-TD, when used in conjunction with the PC-CIT, is an open system interconnection (OSI) proxy that accepts TCP/IP connections and sets up matching OSI connections. This requires the support of the TCP/IP stack and the seven-layer OSI stack.
Front IAO LAN interface
The DMX provides an RJ45-compatible front IAO LAN interface that is intended for use with a local PC. This interface will support a
TL1/TCP gateway via an IEEE 802.3-compliant interface with a graphical user interface (GUI) in future releases.
Rear IAO LAN interface
TL1 over TCP/IP or TL1 over OSI LAN is supported via an
RJ45-compatible IAO LAN rear interface (R1.1) on the DMX, enabling the DMX to connect with any NMS possessing a compatible
TCP/IP or OSI interface (such as the EMS or the PC-CIT). This allows
TL1 communication over a data network between several different
NEs. For instance, Lucent’s Navis Element Management System
(EMS) can communicate with a DDM-2000 that is on the same network as the DMX connected to the EMS via the rear IAO LAN interface. The IAO LAN complies with OSI requirements as specified in GR-253-CORE, Section 8.
SONET DCC
The SONET DCC provides TL1 over OSI connections with remote
NEs in a subnetwork.
...........................................................................................................................................................................................................................................................
1 0 - 1 4 6
365-372-300
Issue 8.0, September 2006
Technical Specifications
Personal Computer Specifications for Software Download
............................................................................................................................................................................................................................................................
Specifications
The PC used for software download should have:
• Windows NT or 2000
• CD-ROM drive for CD-ROM download.
Compatible modems
A compatible modem must meet the following minimum requirements:
• 300, 1200, 2400, 4800, 9600, 19,200 or 115,000 baud
• Full duplex
• 8 data bits
• No parity bits
• 1 start bit
• 1 stop bit
• No flow control.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 0 - 1 4 7
Technical Specifications
LEDs, Indicators, and Office Alarms
............................................................................................................................................................................................................................................................
LNW1 and LNW2 SYSCTL
Faceplate
The LNW1 and LNW2 SYSCTL circuit pack faceplate contain the following push-button switches and LEDs (LNW2 specific items are labeled as such):
• ACTIVE LED (LNW2 only)
• FAULT LED
• Critical (CR) LED
• Major (MJ) LED
• Minor (MN) LED
• Abnormal (ABN) LED
• Far End Activity (FE) LED
• Near End Activity (NE) LED
• Alarm Cut-Off/Test (ACO) LED
• ACO/TEST (ACO SW) button
• Select (SEL) button
• Update/Initialize (UPD INIT) button
• 7-segment numeric display (LNW1), or alphanumeric LED display (LNW2)
The seven segment/alphanumeric LED numeric display is used to identify the remote system presently displayed on the local user panel.
A green PWR ON LED is lighted when the shelf is receiving -48 V power. A green ACO LED is lighted when the ACO function is active.
The SEL, ACO SW, and UPD INIT push-buttons are provided to control system operation.
The LNW2 contains increased memory to support the enhanced feature set in R6.0 and upcoming releases. It must be used with R6.0. The
LNW1 supports R5.x and prior releases.
Equipment indicators
A red LED FAULT indicator is provided on all circuit packs. A green
LED ACTIVE indicator is provided on all 1x1 protected circuit packs to indicate which circuit packs are actively carrying traffic.
Office Alarms
The office alarms interface is a set of discrete relays that control office audible and visual alarms. Separate relays handle CR, MJ, and MN alarms. Each contact closure is rated at 1 A, 60 V maximum. The CR
...........................................................................................................................................................................................................................................................
1 0 - 1 4 8
365-372-300
Issue 8.0, September 2006
LEDs, Indicators, and Office Alarms
Technical Specifications
and MJ alarms can be wire-ORed. The CR alarm relays are fail safe against unprotected power failures.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 0 - 1 4 9
Technical Specifications
User-setable Miscellaneous Discrete Interface
............................................................................................................................................................................................................................................................
Overview
The user-setable miscellaneous discrete interface allows an operations system (OS) to control and monitor equipment collocated with the
DMX through a set of input and output contact closures. Miscellaneous discrete environmental inputs can monitor conditions like open doors or high temperature, miscellaneous discrete outputs control equipment such as fans and generators. The status of the miscellaneous discrete environmental inputs can be queried on demand via the DMX PC-CIT.
DMX collects miscellaneous discrete alarms and automatically sends them to the operations system (OS)
.
External customer equipment
Any external customer equipment to be monitored by DMX must provide the electrical equivalent of a contact closure across the corresponding environmental input wiring pairs. The contact closure must be capable of passing at least 10 mA of drive current.
Power source
Reference
The power source to enable the control of external customer equipment may have a voltage range from a minimum of 3 V to a maximum of
72 V. DMX provides a unidirectional opto-isolator connection across each corresponding control output wiring pair. The load current across each control output wiring pair must be limited by the external customer equipment and must not exceed 35 mA.
For detailed wiring information, refer to the Metropolis
®
DMX Access
Multiplexer Installation Manual, 365-372-304 and Metropolis
®
DMX
Access Multiplexer Application Schematic, SD8C500-01.
...........................................................................................................................................................................................................................................................
1 0 - 1 5 0
365-372-300
Issue 8.0, September 2006
Technical Specifications
Physical Specifications
Overview
............................................................................................................................................................................................................................................................
Purpose
This section provides DMX physical characteristics, including environmental and power specifications.
Contents
The following specifications are included in this section:
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 0 - 1 5 1
Technical Specifications
Physical Specifications
............................................................................................................................................................................................................................................................
DMX High Capacity shelf physical characteristics
The DMX High Capacity shelf has the following characteristics:
• Width: 17.6 inches
• Height: 19 inches (includes integral fan unit)
• Depth (front to back): 13.75 inches
• Weight (with circuit packs): 57 pounds
• Weight (without circuit packs): 38 pounds
...........................................................................................................................................................................................................................................................
1 0 - 1 5 2
365-372-300
Issue 8.0, September 2006
Technical Specifications
Environmental Specifications
............................................................................................................................................................................................................................................................
Temperature and humidity
The DMX shelf meets Telcordia Technologies’ Network Equipment
Building System (“NEBS Generic Equipment Requirements,”
GR-63-CORE) requirements for use in CO environments.
A Fan Assembly is required above the standard DMX shelf in any environment except an outside cabinet (with ventilation) application.
The DMX High Capacity shelf has a fan unit built into the bottom of the shelf.
The DMX is environmentally hardened and will function at temperatures of -40 o
C to +65 o
C and humidity of 5 to 95 percent
(noncondensing) in all TDM applications when equipped with the following circuit packs:
LNW1, LNW2, LNW6, LNW7, LNW16, LNW18, LNW19, LNW19B,
LNW28, LNW32, LNW36, LNW37, LNW45, LNW46, LNW48,
LNW49, LNW50, LNW54, LNW63, LNW74, LNW80.
In all other applications the DMX functions at temperatures of 0 o
C to
+50 o
C.
Important!
The DMX Standard Shelf has been DA’d and is no longer available. The High Capacity shelf is available.
EMC requirements
The DMX has been tested and found to comply with the limits for a
Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio-frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residence is likely to cause harmful interference in which case the user will be required to correct the interference at the user’s own expense.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 0 - 1 5 3
Environmental Specifications
Technical Specifications
Earthquake requirements
DMX meets the earthquake requirements defined in Telcordia
Technologies GR-63-CORE and Pacific Bell Standard
PBS-000-102PT.
Fire resistance
DMX meets ignitability requirements specified in ANSI T1.307-1997.
In addition, the DMX meets the fire resistance requirements of UL
60950, 3rd Edition.
Underwriters Laboratories
The DMX is UL recognized for restricted access installations in business and customer premises applications installed in accordance with Articles 110-16 and 110-17 of the National Electric Code,
ANSI/NFPA Number 70-87. Other installations exempt from the requirements of the National Electric Code may be engineered according to the accepted practices of the local telecommunications utility.
Canadian Standards
Association
The DMX has been certified by the Canadian Standards Association per standard CAN/CSA-C22.2 Number 60950-00.
...........................................................................................................................................................................................................................................................
1 0 - 1 5 4
365-372-300
Issue 8.0, September 2006
Technical Specifications
Power Specifications
............................................................................................................................................................................................................................................................
Power supply
The following table lists DMX High Capacity shelf power requirements.
Table 10-83 DMX 30 Amp High Capacity Shelf Power Supply
Requirements
Item
Voltage range, all components
Description
-40.0V to -60.0V
Power Feeders two -48V power feeders
[BREAKER (A) and BREAKER (B)]
Circuit Breakers (two per shelf) 30.0 A
The following table lists DMX 20 Amp High Capacity shelf power requirements.
Table 10-84 DMX 20 Amp High Capacity Shelf Power Supply
Requirements
Item
Voltage range, all components
Power Feeders
Description
-40.0V to -60.0V
two -48V power feeders
[BREAKER (A) and BREAKER (B)]
Circuit Breakers (two per shelf) 20.0 A
Circuit breakers
DMX uses on-board power conversion eliminating the need for slots for bulk power converters. Two independent -48V office power feeders
(A and B) enter the shelf through connectors and are filtered and distributed to the circuit packs through circuit breakers. Power conversion is performed through modular power converters located on the circuit packs. In each circuit pack, the feeders are diode ORed, fused, filtered, and regulated by the board-mounted power modules.
This provides the required redundancy in case of the loss of one feeder or circuit breaker. The green Power LEDs located next to each circuit breaker (A and B) indicate power is being fed to the breaker.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 0 - 1 5 5
Power Specifications
Technical Specifications
Current drains
The following table provides the maximum and average current drain requirements for a shelf if only one feeder is present.
Table 10-85 High-capacity Shelf Current Drains
Shelf Current Drains in Amperes
Typical @
−
48V
DMX High Capacity Shelf 6.3
Maximum
@
−
23.0
48V
Typical
@
−
40V
7.5
Maximum
@
−
40V
27.5
The following table provides the maximum and average current drain requirements for a bay equipped with four high-capacity shelves.
Table 10-86 Bay Current Drains
Bay Current Drains
Typical @
−
48V
Maximum
@
−
48V
25.2
92.0
Typical
@
−
40V
30.0
Maximum
@
−
40V
110.0
Bay equipped with four
DMX High Capacity
Shelves
The following table provides the maximum and typical heat dissipation figures for the High Capacity Shelf.
Table 10-87 High-capacity Shelf Heat Dissipation
Shelf
DMX High Capacity
Heat Dissipation in Watts
Typical @
−
48V
Maximum
@
−
48V
302 1100
Typical
@
−
40V
300
Maximum
@
−
40V
1100
...........................................................................................................................................................................................................................................................
1 0 - 1 5 6
365-372-300
Issue 8.0, September 2006
Technical Specifications
External Equipment Specifications
Overview
............................................................................................................................................................................................................................................................
Purpose
This section provides specifications for equipment frequently used with, but external to the DMX shelf.
Contents
The following specifications are included in this section:
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
1 0 - 1 5 7
Technical Specifications
External Optical Amplifier
............................................................................................................................................................................................................................................................
Overview
The following tables present the optical specifications for the external optical amplifier.
Optical specifications
The table below lists the optical specifications for the amplifier.
Table 10-88 Optical specifications
Parameter
Wavelength Range
Input Power Range
Output Power
Signal Gain
Noise
Signal Gain
FDA Classification
Polarization Mode Dispersion
Minimum
1530 nm
-27 dBm
13 dB
7.0 (for 22 dB Gain)
13 dB
Maximum (or basic value if there is no min/max measurement.
1563 nm
4 dBm
17 dBm
22 dB
16.0 (for 13 dB Gain)
22 dB
Class 1M (IEC 60825)
—
viewing the laser output with optical instruments can pose an eye hazard.
0.5 ps @ -20 dBm input
Performance Monitoring and Alarms
The below is a list of the alarms and alarm thresholds reported on the amplifier.
• Degradation of input signal
• Loss of input signal
• Excessive pump current
• EDFA case temperature out of range
• Degradation of output signal
• Loss of output signal
• Excessive TEC current
• Gain out of range
...........................................................................................................................................................................................................................................................
1 0 - 1 5 8
365-372-300
Issue 8.0, September 2006
A: Ethernet/SAN
Overview
............................................................................................................................................................................................................................................................
Purpose
This section describes the Ethernet implementation for the Metropolis
®
DMX Access Multiplexer (DMX).
Contents
The following topics are covered:
Introduction to Ethernet Services
Ethernet Service Configurations
SONET-Based Distance Extensions for
ESCON/FICON/Fibre-Channel Services
365-372-300
Issue 8.0 September 2006
A - 1
: Ethernet/SAN
Introduction to Ethernet Services
............................................................................................................................................................................................................................................................
Ethernet services
Ethernet services are what network operators provide their subscribers.
DMX supports Private Line, Private LAN, Virtual Private LAN, and
Virtual Private Line.
The Private services are transported over their own dedicated SONET timeslots. If present, Ethernet switching functions may or may not be shared.
Subscribers of Virtual Private services share network bandwidth to take advantage of the efficiency of statistical multiplexing that is available due to the intermittent nature of data transmission. VLAN Tags are used to separate subscribers and maintain privacy. DMX supports
VLANs in the 1-4093 range for customer identification and isolation.
Private Line services are point-to-point in nature while Private LAN services are multipoint. Private LAN services always involve internal
Ethernet switching while Private Line services do not.
Private line
Private Line service provides a dedicated link between two locations.
The Ethernet ports and SONET bandwidth are dedicated to the subscriber and not shared. Private line service is characterized by minimal provisioning - typically just the SONET cross-connection. A subclass, Fractional Private Line, is distinguished by less than
Ethernet-line-rate SONET connectivity. It is a form of rate control that also improves efficiency by only consuming the required SONET bandwidth in STS-1 increments. For more information about how
STS-1 tributaries can be virtually concatenated to provide Fractional
Private Line service, refer to “Virtual concatenation” (A-33)
Another characteristic of Private Line service is little or no Layer 2 functionality. With Fast Ethernet, the physical layer must be terminated precluding transparency of auto-negotiation. In addition, performance of the Fractional Private Line may be improved by enabling flow control, a Layer 2 function. For more information about flow control, refer to “Flow control” (A-59) .
A - 2
365-372-300
Issue 8.0 September 2006
Introduction to Ethernet Services
: Ethernet/SAN
MAC address learning is another function. For more information about
MAC address learning, refer to “Ethernet LAN/VCG port density” (A-43) . Circuit packs that support multiple service modes
(Private Line and switched services such as Private LAN), for example the LNW67 1GSX circuit pack, typically have more Layer 2 functions available in the Private Line mode than circuit packs such as the
LNW71 10/100-PL that only support Private Line. For more information about Ethernet circuit packs, refer to
Private LAN
Private LAN service extends the concept of Private Line to connect more than two locations in an extended Ethernet LAN. This is accomplished by introducing embedded Ethernet switching at each node. The SONET bandwidth is still dedicated to one subscriber.
Because this is a switched service, the attendant QoS features are available.
VLAN tagging is an integral part of Private LAN service. VLANs are used to distinguish customers or organizations within customers. In the
Transparent Mode, the service provider provisions a port tag, or customer ID, for each DMX Ethernet port. This port tag is added to each incoming packet and carried with the DMX network in order to keep the traffic for each subscriber separate. When the packets exit the
DMX network, the port tag is removed. Any subscriber-inserted VLAN tags within the packets are carried through the network unchanged.
In 802.1Q mode, the provider coordinates VLAN tags with the subscriber to further manage traffic flows. For example, some VLANs can limit traffic among particular groups of sites representing communities of interest while others may be used for traffic common to all. This can be coupled with QoS features such as PIR and priorities to optimize the Private LAN network. For more information about
Quality of Service, refer to
. For more information about Tagging modes, refer to
365-372-300
Issue 8.0 September 2006
A - 3
Introduction to Ethernet Services
: Ethernet/SAN
Virtual Private LAN
Virtual Private LAN service extends the concepts of Private LAN service to include bandwidth sharing among multiple customers. In this way, less SONET bandwidth can be used to serve customers by taking advantage of the efficiency of statistical multiplexing. VLAN tags or port tags are used to keep each subscriber’s traffic private.
Virtual Private Line
Virtual Private Line, a shared service between two points, is a special case of Virtual Private LAN. It requires the use of Ethernet switching functions and is therefore configured and managed in the same way as
Virtual Private LAN.
Network topologies and configurations
Network topologies consist of two layers: the packet layer and the underlying SONET layer. Packet networks can be created over a variety of SONET topologies, and have different properties as a result.
For example, a Private Line service uses a point-to-point packet topology, but may be carried over a SONET ring, which may in turn be configured with UPSR protection or no SONET protection.
The following packet topologies are supported:
• Point-to-point
• Multipoint
• Hub-and-spoke.
Point-to-Point
The point-to-point topology is used to join two nodes. For example, a business may connect to an ISP via a point-to-point connection.
Because of its simplicity point-to-point configurations have a variety of protection options available. They may use any of the SONET layer protection mechanisms. They may also forgo SONET protection and use data-layer protection such as Link Aggregation.
Multipoint
In a multipoint network all points converse with each other. Note that connecting three locations by two point-to-point connections is not the same as if done by a multipoint connection. The location in the middle of the point-to point connections would have to provide external switching to enable the outer locations to converse with each other.
A - 4
365-372-300
Issue 8.0 September 2006
Introduction to Ethernet Services
: Ethernet/SAN
One useful case of multipoint configurations is a packet ring. In a closed-ring configuration all nodes may converse. An internal spanning tree may be configured for protection and loop prevention (this is not necessary with RPR). This is independent of any spanning tree protocol that may be running on the subscriber's network. The spanning tree
breaks one link, necessary with a ring of interconnected bridges. In the case of a link failure, the spanning tree algorithm restores connectivity by moving its break to coincide with the failed link.
A special case of multipoint configuration is where one node acts as a hub and all other nodes converse only with it. This hub configuration differs from a hub-and-spoke network only in that the spokes share bandwidth to reach the hub. It is more efficient and may be more practical because it conserves hub ports; only two VCG (WAN) ports are needed, regardless of the number of spokes. (In a packet ring configuration the broken link is placed between the two nodes most remote from the hub; because those nodes don't converse, there is no loss of useful bandwidth.) Both this topology and the hub-and-spoke described next are sometimes called point-to-multipoint.
Hub-and-spoke
The hub-and-spoke network is a hybrid between point-to-point and multipoint. Each node connects to the hub via a dedicated link; but, the links terminate on an embedded switch at the hub. In a typical back-haul application, the switch aggregates the traffic into a single
Ethernet link for hand off. As in the multipoint hub network, tags are used to identify and direct traffic to and from the hub.
Applications
Ethernet applications are examples of what users can do with the services and topologies described in previous sections. The user can be the owner of the equipment or a client of the owner. For example, an
ISP can have a private network or buy the services from an LEC to construct the application.
DMX supports the following applications:
• LAN interconnect
• LAN extension
• ISP access
• Internet access
• Video distribution
365-372-300
Issue 8.0 September 2006
A - 5
Introduction to Ethernet Services
: Ethernet/SAN
LAN Interconnect
Two or more enterprise LANs are interconnected. The LANs may be point-to-point Private Line connections, in which case Ethernet switching services are not provided. If Virtual Private Lines are desired, Ethernet switching is required. Even so, in a three-node LAN
Interconnect application composed of Virtual Private Lines the middle node has two termination ports, one for each neighbor. This is different from a three-node LAN Extension (next application) using Virtual
Private LAN in which the middle node may have only one (effectively a hub) port.
LAN Extension
Sometimes called intranet or Layer 2 VPN, this extends an enterprise
LAN to multiple locations via embedded Ethernet switching. Either
Private LAN or Virtual Private LAN may be used.
Transparent LAN is a common form of LAN Extension in which the subscriber's traffic is transported without regard to the presence of subscriber VLAN tags. Transparency is achieved by the use of Port
Tags, avoiding the need for the provider to administer VLANs with subscribers. The Port Tag is effectively a customer ID; only ports in the network assigned a particular customer ID will exchange traffic.
In Non-Transparent LANs, greater flexibility is available when the subscriber's 802.1Q tags are used for traffic management (802.1Q mode). For example, the priority bits within the tag can be used to give a portion of the subscriber's traffic, for example VoIP, preferential treatment through the network versus its file transfer or internet traffic.
DSCP (available in R6.0) offers an alternative to priority bits. DSCP can also be used to give certain packets/data streams preferential treatment.
Although in a Virtual Private LAN service a Non-transparent LAN application requires the administration of VLAN Id's among customers, in a Private LAN where no other customers share the embedded
Ethernet switch this is not necessary. For more information about priority bits, refer to “Priorities” (A-47) .
A - 6
365-372-300
Issue 8.0 September 2006
Introduction to Ethernet Services
: Ethernet/SAN
ISP Access
In this application an ISP uses a provider's network to collect internet traffic. It is also an example of a trunking application, where traffic from multiple customers is handed off to the ISP router on a single trunk link for efficiency. The Virtual Private LAN service may be used to efficiently transport the best-effort internet traffic. It is typically done using the 802.1Q mode for separating the ISP's clients' traffic. If the
ISP's router supports stacked VLANs then it can be done in Transparent
Mode The trunk link may be GbE while the access links may be 10 or
100 Mb/s Ethernet.
Internet Access
In this application the ISP owns the network. In this case the clients' traffic is untagged. The ISP adds tags for customer separation using the
802.1Q mode. The ISP administers the tags directly, there is no third party involved.
Video Distribution
Video distribution can be accomplished using Ethernet Multicasting. A
Private LAN service is used to guarantee the bandwidth. Video traffic, generated at the head end, is sent using a multicast address. Transparent mode or 802.1Q mode may be used. At each node the traffic is dropped to its user and also duplicated and sent to the rest of the Private LAN.
Important!
Because of the duplication process, the maximum throughput is only half the line rate on the LNW67 and LNW68
(500 Mb/s).
An alternative is to use SONET drop-and-continue cross-connections to implement multicasting. This is a variation of the Private LAN service. Although it is limited to one-way video distribution, it supports full line rate throughput.
365-372-300
Issue 8.0 September 2006
A - 7
: Ethernet/SAN
Ethernet/SAN Circuit Packs
............................................................................................................................................................................................................................................................
1000BASE-SX/LX/ZX (4 ports)
Private Line
1000BASE-SX/LX/ZX (4 ports)
Private Line
10/100T
(24 ports)
10/100 PL (24 ports)
Private Line
1GbE SX
(2 ports)
1GbE LX
(2 ports)
Enhanced Ethernet Switch Pack
(10/100/1000 BASE-T or
1000BASE-LX/SX
—
4 ports,
10/100 LX
—
4 ports
Overview
DMX supports the following Ethernet circuit packs:
Application/Circuit Pack Code
LNW63
LNW64
LNW66
LNW71
LNW67
LNW68
LNW70
Compatible
Shelf Slots
A-G
(See Note 1)
A-G
(See Note 1)
Description
1000BASE-SX/LX/ZX Ethernet interface via optical PTMs, can be used is slot 1 and/or 2 in a VLF equipped
DMX and either slot 1 or 2 in a non-VLF equipped DMX, GbE private lines, includes no switch fabric, OSP hardened
1000BASE-SX/LX/ZX Ethernet interface via optical PTMs, can be used is slot 1 and/or 2 in a VLF equipped
DMX and either slot 1 or 2 in a non-VLF equipped DMX, GbE private lines, includes no switch fabric, OSP hardened
100BASE-TX Ethernet interface A-D
(See Note 2)
A-D
(See Note 2)
A-G
(See Note 1)
A-G
(See Note 1)
A-G
(See Note 1)
100BASE-TX PL Ethernet interface, supports Ethernet Private Lines
1000BASE-SX Ethernet interface, may occupy slot 1 or 2 of a function group or a growth slot, requires multi-mode cable
1000BASE-LX Ethernet interface, may occupy slot 1 or 2 of a function group or a growth slot, requires single-mode cable
Hybrid 10/100/1000 BASE-TX or
1000BASE-X (ports 1-4), and 100
BASE-LX (ports 5-8) Ethernet interface, may only occupy slot 1 of a function group or a growth slot, uses
PTMs, supports enhanced Ethernet QoS
A - 8
365-372-300
Issue 8.0 September 2006
Ethernet Circuit Packs
: Ethernet/SAN
Application/Circuit Pack
FC-DATA
(SAN Interface)
FC-DATA w/ compression
(SAN Interface)
100BASE-LX
(8 ports)
10/100BASE-TX
(16 ports)
Private Line
RPR 1GbE X
(1000BASE-LX/SX
—
2 ports 100
LX
(4 ports)
Code
LNW73
LNW74
LNW78
Compatible
Shelf Slots
A-G
(See Note 1)
LNW73C
A-G
(See Note 1)
A-G
(See Note 1)
A-G
(See Note 1)
Description
4 ports, PTM optics supporting either
FICON/Fibre-Channel or ESCON
4 ports, PTM optics supporting either
FICON/Fibre-Channel or ESCON, also supports compression of SAN traffic
Hybrid 100BASE-LX and 10/100
BASE-TX Ethernet interface, OSP hardened, may only occupy slot 1 of a function group or a growth slot, uses
PTM optics for LX interfaces, supports private lines, when in G1 slot, only the optical ports (17-24) of the LNW74 function
Hybrid 1000BASE-X and 100
BASE-LX Ethernet interface, may only occupy slot 1 of a function group or a growth slot, uses PTM optics, supports
RPR protection and enhanced Ethernet
QoS
Notes:
1. 1. In order to support Ethernet and SAN packs in both Slot 1 and 2 of a
Function Group or Growth Slot, DMX must be equipped with VLF Mains
(LNW59) and R7.0 software.
2. 2. DMX does not allow installation of two packs with electrical interfaces in adjacent slots within the same Function Unit or Growth Slot. Therefore, in systems equipped with LNW59 VLF mains, LNW66 and LNW71 packs can reside in either Slot 1 or Slot 2 of a group, but not both at the same time.
However, another optical (Ethernet or SONET) pack may be installed in the other slot. In non-VLF equipped shelves, LNW66 and LNW71 can only occuppy Slot 1 of a paticular group.
365-372-300
Issue 8.0 September 2006
A - 9
Ethernet Circuit Packs
: Ethernet/SAN
4-Port GbE-PL Private Line
Fast Ethernet circuit pack
(LNW63)
The GbE-PL Private Line Gigabit Ethernet (LNW63) circuit pack provides point-to-point (Ethernet Private Line Service) data transport at the 1000 Mb/s rate. The GbE-PL circuit pack supports generic framing procedure (GFP) encapsulation and STS virtual concatenation.
The LNW63 circuit pack supports STS-1, STS-3c, STS-12c cross-connects. LNW63 has 4 VCGs, and each VCG can have up to 21
STS-1 tribs and the total available backplane link space is 48 STS-1s to
Main-1 and 48 STS-1s to Main-2. The tribs may be assigned freely, all
VCGs have access to all tribs (
Figure A-1 shows the LNW63 circuit
pack).
Each VCG can use 1 STS-1, or up to 21 (STS-1-xv, x=1-21) tributaries.
Each VCG can use 1 STS-3c, or up to 7 (STS-3-xv, x=1-7) or 1
STS-12c tributary.
Figure A-1 LNW63 Gigabit Ethernet (Private Line) Circuit Pack
1 2 3
1000BASE-X
LAN 1 GFP VCG1
LAN 2 GFP VCG2
A - 1 0
LAN 3 GFP VCG3
LAN 4
GFP VCG4
JK-E-15.eps
Legend:
1 External Ethernet Port
2 Generic Framing Procedure
3 Virtual Concatenation Group
LNW63 packs can be placed in Slot 1 of any function group or growth slot in the shelf (A1-G1) and DMX supports a total add/drop capacity of 20 private line GbE ports if all slots are equipped with LNW63 circuit packs.
For detailed information about Ethernet technologies, refer to
365-372-300
Issue 8.0 September 2006
Ethernet Circuit Packs
: Ethernet/SAN
When the LNW63 circuit packs occupy slot 1 of a Function Unit group, slot 2 must be populated with an apparatus blank.
The LNW63 contains 4 internal 1000 Mbps WAN ports supporting enhanced private line services such as high-order virtual concatenation
(STS) and Link Capacity Adjustment Scheme (LCAS). The LNW63 and PTM optics are also OSP hardened for outside plant applications.
100BASE-T/1000BASE-T Electrical PTM (R7.0)
The LNW63 now supports a dual function electrical PTM that is provisionable for 100 or 1000 Mbps traffic. It conforms to the
IEEE802.3 standards for 100BASE-T and 1000BASE-T in its respective settings (IEEE802.3z and IEE802.3ab). Connectivity is provided for an RJ-45 Cat 5 cable and the PTM has a maximum span length of 100 meters.
The electrical PTM can be installed in ports 1-4 of the LNW63.
365-372-300
Issue 8.0 September 2006
A - 1 1
Ethernet Circuit Packs
: Ethernet/SAN
8-port GbE-PL Private Line
Fast Ethernet circuit pack
(LNW64)
The 8-port GbE-PL Private Line Gigabit Ethernet (LNW64) circuit pack provides point-to-point (Ethernet Private Line Service) data transport at the 1000 Mb/s rate. The GbE-PL circuit pack supports generic framing procedure (GFP) encapsulation and STS virtual concatenation.
The LNW64 provides 8 private line, PTM (also known as SFP) GbE ports. The ports can be populated with 8 1000BASE-SX/LX/ZX PTMs or 8 100/1000BASE-TX electrical PTMs, though only 1000BASE-TX rates are supported on the LNW64. LNW64 can also support a mix of 4 electrical and 4 optical PTMs.
LNW64 supports STS-1 and STS-3c cross-connections with or without
VCAT, and STS-12c cross-connections without VCAT. All ports are capable of transmitting at wire speed (1000 Mbps) simultaneously, making full capacity of the pack 168 STS-1s. LNW64 has 8VCGs, and each VCG can have up to 21 STS-1 tribs. The tribs may be assigned
freely, all VCGs have access to all tribs ( Figure A-2 shows the LNW64
circuit pack).
Each VCG can use 1 STS-1, or up to 21 (STS-1-xv, x=1-21) tributaries.
Each VCG can use 1 STS-3c, or up to 7 (STS-3-xv, x=1-7) or 1
STS-12c tributary.
Figure A-2 LNW64 Gigabit Ethernet (Private Line) Circuit Pack
1
2
3
1000BASE-X
LAN 1
LAN 2
LAN 3
LAN 4
LAN 5
LAN 6
LAN 7
LAN 8
GFP VCG1
GFP VCG2
GFP VCG3
GFP VCG4
GFP Vc5
GFP VCG6
GFP VCG7
GFP VCG8
JK-E-20.eps
Legend:
1 External Ethernet Port
2 Generic Framing Procedure
3 Virtual Concatenation Group
A - 1 2
365-372-300
Issue 8.0 September 2006
Ethernet Circuit Packs
: Ethernet/SAN
With VLF Mains, LNW64 can occupy both slots 1 and 2 of a
Function/Growth unit, making the total capacity of a systems fully populated with LNW64s, 80 GbE private line ports. When the LNW64 is installed in a Growth slot, only the optical PTMs can be used.
For detailed information about Ethernet technologies, refer to
When the LNW64 circuit packs occupies one slot of a Function Unit group, the other must be populated with an apparatus blank.
The LNW64 contains 8 internal 1000 Mbps WAN ports supporting enhanced private line services such as high-order virtual concatenation
(STS) and Link Capacity Adjustment Scheme (LCAS). The LNW64 and PTM optics are also OSP hardened for outside plant applications.
365-372-300
Issue 8.0 September 2006
A - 1 3
Ethernet Circuit Packs
: Ethernet/SAN
FC/FICON/ESCON SAN circuit pack (LNW73 and
LNW73C)
LNW73 and LNW73C circuit pack provides point-to-point SAN transport. The LNW73/73C circuit pack supports generic framing procedure (GFP) encapsulation and STS virtual concatenation. The
LNW73/73C circuit pack can be provisioned to operate in the STS-1 or
STS-3c mode. In the STS-1 mode, the The LNW73/73C circuit pack supports up to 24 VCG ports. In the STS-3c mode, the The
LNW73/73C circuit pack supports up to 16 VCG ports.
The LNW73/73C circuit pack supports STS-1, STS-3c, STS-12c cross-connect. The LNW73/73C has 4 VCGs, and each VCG can have up to 48 tribs (maximum capacity of 48 virtual concatenated STS-1s) and the total available backplane link space is 48 STS-1s to Main-1 and
48 STS-1s to Main-2. The tribs may be assigned freely, all VCGs have access to all tribs (
shows the The LNW73/73C circuit pack).
When the The LNW73/73C is provisioned for STS-1 mode, each VCG can use 1 STS-1, or up to 48 (STS-1-xv, x=0-48) tributaries. When the
LNW63 is provisioned for STS-12c mode, each VCG can use 1
STS-3c, or up to 16 (STS-3-xv, x=1-16) or 1 STS-12c tributary. The circuit pack mode is user provisionable.
Figure A-3 LNW73/73C Gigabit Ethernet (Private Line) Circuit
Pack (STS-1 Mode)
1
2
3
1000BASE-X
LAN 1 GFP VCG1
LAN 2
GFP VCG2
LAN 3
LAN 4
GFP VCG3
GFP VCG4
JK-E-15.eps
Legend:
1 External Ethernet Port
2 Generic Framing Procedure
3 Virtual Concatenation Group
A - 1 4
365-372-300
Issue 8.0 September 2006
Ethernet Circuit Packs
: Ethernet/SAN
The LNW73C differs from the LNW73 in that it enables compression of SAN traffic.
The LNW73C is able to compress asychronous Fibre Channel traffic and conserve up to 50% of bandwidth versus uncompressed asynchronous FC traffic in typical applications.
Compression for asynchronous FC traffic is pre-standard and will be standardized by FC-BB-4. The R6.0 implementation of SAN compression enables a high throughput of up to two full-line rate
FC-2G interfaces in a single pack.
The R6.0 implementation of SAN compression enables a high throughput of up to two full-line rate FC-2G interfaces in a single pack.
LNW73/73C packs can be placed in Slot 1 of any function group or growth slot in the shelf (A1-G1) and DMX supports a total add/drop capacity of 20 private line GbE ports if all slots are equipped with
LNW73/73C circuit packs.
For detailed information about Ethernet technologies, refer to
When the LNW73/73C circuit packs occupy slot 1 of a Function Unit group, slot 2 must be populated with an apparatus blank.
The LNW73/73C contains 4 internal 1000 Mbps WAN ports supporting enhanced private line services such as low-and high order virtual concatenation (VT1.5/STS) and Link Capacity Adjustment
Scheme (LCAS). The LNW73/73C and PTM optics are also OSP hardened for outside plant applications.
365-372-300
Issue 8.0 September 2006
A - 1 5
Ethernet Circuit Packs
10/100T Fast Ethernet circuit pack (LNW66)
: Ethernet/SAN
The 10/100T Fast Ethernet (LNW66) circuit pack has 24 LAN ports and provides data transport at the rate of 10/100 Mb/s using standard
Ethernet bridging, generic framing procedure (GFP) encapsulation, and
STS-1 virtual concatenation. (Refer to Figure A-4 .) Connections to the
100BASE-TX interface are via multi-service connectors on the DMX system backplane.
Each LAN port performs protocol transparent filtering and bridging of incoming media access control (MAC) frames. MAC frames with a destination address on the local bus are filtered by the 10/100T circuit pack to prevent unnecessary transmission of frames over the wide area network (WAN). The ports auto-negotiate mode (full/half duplex), speed (10/100 Mb/s), and flow control when interfacing with other
802.3-compliant devices over twisted pair media. The LNW66 can group (concatenate) between 1 and 21 STS-1 SONET tributaries.
Figure A-4 LNW66 Fast Ethernet Circuit Pack
1 2 3 4
A - 1 6
10
11
12
13
14
15
16
17
18
5
6
7
8
9
1
2
3
4
19
20
21
22
23
24 v1
Ethernet
Switch v2
GFP VCG1
GFP VCG2 nc-dmx-093
Legend:
1 External Ethernet Port
2 Virtual Concatenation Group Port
3 Generic Framing Procedure
4 Virtual Concatenation Group
For detailed information about Ethernet technologies, refer to
The 10/100T circuit pack must be housed in slot 1 of a Function Unit group (A, B, C, or D-- Not G) and is not equipment protected.
However, facility protection can be provided through the WAN via
365-372-300
Issue 8.0 September 2006
Ethernet Circuit Packs
: Ethernet/SAN
SONET UPSR or through the spanning tree algorithm. When the
10/100T circuit pack occupies slot 1 of a Function Unit group, slot 2 must be populated with a 177D apparatus blank or an LNW98
Detectable Blank circuit pack.
365-372-300
Issue 8.0 September 2006
A - 1 7
Ethernet Circuit Packs
: Ethernet/SAN
1GSX Gigabit Ethernet circuit pack (LNW67)
The 1GSX (LNW67) circuit pack provides a short-reach, 2-port,
1000BASE-SX, IEEE 802.3-compliant interface. The 1GSX circuit pack provides short-reach high-speed optical data transport at the rate of 1 Gb/s using standard Ethernet bridging, generic framing procedure
(GFP) encapsulation, and STS-1 virtual concatenation. (Refer to Figure
A-5 .) Fiber access is provided by two LC-type connector pairs on the
circuit pack faceplate. The 1GSX circuit pack transmits signals at a wavelength of 850 nm. The SX ports require a 50
µ m or 62.5
µ m multimode optical cable and transmit up to 550 meters. The LNW67 can group (concatenate) between 1 and 21 STS-1 SONET tributaries.
Figure A-5 Gigabit Ethernet Circuit Pack
1 2 3 4
A - 1 8 v1
GFP VCG1
1 v2
2
Ethernet
Switch v3
GFP VCG2
GFP VCG3 v4 GFP VCG4 nc-dmx-094
Legend:
1 External Ethernet Port
2 Virtual Concatenation Group Port
3 Generic Framing Procedure
4 Virtual Concatenation Group
The 1GSX circuit pack performs protocol transparent filtering and bridging of incoming media access control (MAC) frames. MAC frames with a destination address on the local bus are filtered by the
1GSX circuit pack to prevent unnecessary transmission of frames over the wide area network (WAN).
For detailed information about Ethernet technologies, refer to
365-372-300
Issue 8.0 September 2006
Ethernet Circuit Packs
: Ethernet/SAN
The 1GSX circuit pack must be housed in slot 1 of any Function Unit group (A, B, C, D or G) and is not equipment protected. However, facility protection can be provided via SONET UPSR or through the spanning tree algorithm. When the 1GSX circuit pack occupies slot 1 of a Function Unit group, slot 2 must be populated with a 177D apparatus blank or an LNW98 Detectable Blank circuit pack.
Up to 10 1GSX ports are addressable when all Function Unit groups are equipped with 1GSX circuit packs.
365-372-300
Issue 8.0 September 2006
A - 1 9
Ethernet Circuit Packs
: Ethernet/SAN
1GLX Gigabit Ethernet circuit pack (LNW68)
1000BASE-X/100BASE-LX
(LNW70) hybrid optical ethernet interface
The 1GLX (LNW68) circuit pack provides a long-reach, 2-port,
1000BASE-LX, IEEE 802.3-compliant interface. Except for the optical span length, it is functionally the same as the LNW67 1GSX circuit pack. (Refer to
Figure A-5 .) The 1GLX transmits 1310-nm signals
using multimode or single mode optical cable. The port can transmit up to 10000 meters on single-mode fiber. The LNW68 can group (concatenate) between 1 and 21 STS-1 SONET tributaries.
This 8-port Ethernet interface provides 4-ports for short-reach and/or long-reach high-speed optical data transport at the rate of 1 Gb/s and
4-ports for optical 100BASE-LX transport at 100 Mbps using standard ethernet switching IEEE 802.1, standard encapsulation according to
ANSI T1X1.5/2000-024R4 (ITU G.7041), virtual concatenation according to ITU G.707.
The LNW70 circuit pack supports STS-1, STS-3c, STS-12c cross-connect. LNW70 may have up to 32 VCGs, and each VCG can have up to 48 tribs (maximum capacity of 48 virtual concatenated
STS-1s) and the total available backplane link space is 48 STS-1s to
Main-1 and 48 STS-1s to Main-2. The tribs may be assigned freely, all
VCGs have access to all tribs.
When the LNW70 is provisioned for STS-1 mode, each VCG can use 1
STS-1, or up to 48 (STS-1-xv, x=0-48) tributaries. When the LNW70 is provisioned for STS-12c mode, each VCG can use 1 STS-3c, or up to
16 (STS-1-xv, x=0-16) or 1 STS-12c tributary. The circuit pack mode is user provisionable.
Connections to the LNW70 are PTMs on the circuit pack faceplate.
100BASE-T/1000BASE-T Electrical PTM for the LNW70 (R6.0)
The LNW70 now supports a dual function electrical PTM that is provisionable for 100 or 1000 Mbps traffic. It conforms to the
IEEE802.3 standards for 100BASE-T and 1000BASE-T in its respective settings (IEEE802.3z and IEE802.3ab). Connectivity is provided for an RJ-45 Cat 5 cable and the PTM has a maximum span length of 100 meters.
The electrical PTM can only be installed in ports 1-4 of the LNW70.
Ports 5-8 are always reserved for 100BASE-LX optical Fast Ethernet interfaces.
A - 2 0
365-372-300
Issue 8.0 September 2006
Ethernet Circuit Packs
365-372-300
Issue 8.0 September 2006
The figure below shows the LNW70 in Private Line mode.
Figure A-6 LNW70 In Private Line Mode
1
1000BASE-X/ 100/1000BASE-T
LAN 1 GFP VCG1
LAN 2
LAN 3
GFP
GFP
VCG2
VCG3
LAN 4
100BASE-FX
LAN 5
LAN 6
GFP
GFP
GFP
VCG4
VCG5
VCG6
LAN 7
LAN 8
GFP
GFP
VCG7
VCG8
JK-E-1.eps
2
3
Legend:
1 External Ethernet Port
2 Generic Framing Procedure
3 Virtual Concatenation Group
The figure below shows the LNW70 in Switched (802.1q or
Transparent) mode.
Figure A-7 LNW70 In Switched Mode
1 2 3 4
: Ethernet/SAN
1
2 v1 v2
GFP
GFP
3 v3
7
8
4
5
Ethernet
Switch v4
V5
6
V6
V7
V8
GFP
GFP
GFP
GFP
GFP
GFP
VCG1
VCG2
VCG3
VCG4
VCG5
VCG6
VCG7
VCG8
JK-E-16.eps
A - 2 1
Ethernet Circuit Packs
: Ethernet/SAN
Legend:
1 External Ethernet Port
2 Generic Framing Procedure
3 Virtual Concatenation Group
For detailed information about Ethernet technologies, refer to
The LNW70 may occupy slot 1 of any Function Unit group on the shelf
(including Growth slots), and up to 20 1000BASE-X and
20 100BASE-LX ports are addressable when all Function Unit groups are equipped with LNW70 circuit packs. When the LNW70 circuit packs occupy slot 1 of a Function Unit group, slot 2 must be populated with an apparatus blank. However, facility protection can be provided through the WAN via SONET.
A - 2 2
365-372-300
Issue 8.0 September 2006
Ethernet Circuit Packs
: Ethernet/SAN
10/100-PL Private Line Fast
Ethernet circuit pack
(LNW71)
The 10/100-PL Private Line Fast Ethernet (LNW71) circuit pack provides point-to-point (Ethernet Private Line Service) data transport at the 10/100 Mb/s rate. The 10/100-PL circuit pack supports generic framing procedure (GFP) encapsulation and STS-1 virtual concatenation. The LNW71 circuit pack can be provisioned to operate in the STS-1 or STS-3c mode. In the STS-1 mode, the 10/100-PL circuit pack supports up to 24 VCG ports. In the STS-3c mode, the
10/100-PL circuit pack supports up to 16 VCG ports.
When the LNW71 is provisioned for STS-1 (concatenate) mode, each
VCG can use 1 (STS-1v) or 2 (STS-2v) tributaries. When the circuit pack is provisioned for STS-3c mode, all VCGs can use 1 STS-3c or 1
STS-1 tributary. The circuit pack mode is user provisionable.
(
Figure A-8 shows the 10/100-PL circuit pack in the STS-1 mode.)
Connections to the 100BASE-TX interface are via multi-service connectors on the DMX system backplane.
Figure A-8 LNW71 Fast Ethernet (Private Line) Circuit Pack
(STS-1 Mode)
1 2 3
LAN 1
LAN 2
LAN 3
LAN 4
GFP VCG1
GFP VCG2
GFP VCG3
GFP VCG4
365-372-300
Issue 8.0 September 2006
LAN 24 GFP VCG24 nc-dmx-248
Legend:
1 External Ethernet Port
2 Generic Framing Procedure
3 Virtual Concatenation Group
The ports auto-negotiate speed (100 Mb/s) and flow control when interfacing with other 802.3-compliant devices over twisted pair media.
The ports supports the full duplex mode only.
A - 2 3
Ethernet Circuit Packs
: Ethernet/SAN
For detailed information about Ethernet technologies, refer to
The 10/100-PL circuit pack must be housed in slot 1 of a Function Unit group (A, B, C, D) and is not equipment protected. However, facility protection can be provided through the WAN via SONET UPSR.
When the 10/100-PL circuit pack occupies slot 1 of a Function Unit group, slot 2 must be populated with a 177D apparatus blank or an
LNW98 Detectable Blank circuit pack.
A - 2 4
365-372-300
Issue 8.0 September 2006
Ethernet Circuit Packs
: Ethernet/SAN
100BASE-LX/100BASE-TX
(LNW74) hybrid optical/electrical Ethernet interface
This 24-port Ethernet interface provides 8-ports for optical
100BASE-LX transport at 100 Mbps using standard GFP encapsulation according to ANSI T1X1.5/2000-024R4 (ITU G.7041). The LNW74 also provides 16 electrical ports for the 100BASE-TX interfaces. These electrical ports transmit at 10/100 Mbps using standard ethernet IEEE
802.1, standard encapsulation according to ANSI T1X1.5/2000-024R4
(ITU G.7041), LCAS according to IYU G.7042, and standard STS-1 and VT virtual concatenation according to ITU G.707. The LNW74 electrical interfaces can transmit signals across spans as long as 100 meters.
The 10/100-PL circuit pack supports STS-1, STS-3c, and VT1.5 (all may be used on different ports). Up to 336 VT1.5s may be used with between 0 and 63 assigned to any VCG. When VT mapping is selected,
12 STS-1s are reserved for the 336 VTs. Then 36 STS-1s are reserved for STS-1 VCAT or STS-3cs. Otherwise there is no VT mapping. In this case, 48 STS-1s are available for STS-1 VCAT or STS-3cs. Each
VCG can use 1 (STS-1) or (STS-1-xv, x=0-3) or 1 (STS-3c), or
(VT1.5-xv, x=0-63) tributaries. The circuit pack mode is user provisionable.
Connections to the 100BASE-TX interface are via multi-service connectors on the DMX system backplane. Fiber access for optical ports is provided by LC-type connector pairs on the LNW74 faceplate.
365-372-300
Issue 8.0 September 2006
A - 2 5
Ethernet Circuit Packs
A - 2 6
: Ethernet/SAN
The LNW74 circuit pack is designed specifically to support Fast
Ethernet Private Line applications. Each LNW74 circuit pack can support 24 private lines.
Figure A-9 LNW74 Fast Ethernet Hybrid (optical/electrical) Pack
1 2 3
100BASE-TX
LAN 1
LAN 2
GFP
GFP
VCG1
VCG2
LAN15
LAN16
100BASE-FX
LAN17
LAN18
GFP
GFP
VCG15
VCG16
GFP
GFP
VCG17
VCG18
LAN23
LAN24
GFP
GFP
VCG23
VCG24
JK-E-2.eps
Legend:
1 External Ethernet Port
2 Generic Framing Procedure
3 Virtual Concatenation Group
The electrical ports auto-negotiate speed (at 10/100 Mbps for TX ports only-- LX ports operate at 100 Mbps only) and flow control when interfacing with other 802.3-compliant devices over twisted pair media.
The ports supports the full duplex mode only. Optical ports on the
LNW74 do not auto-negotiate flow control.
For detailed information about Ethernet technologies, refer to
The LNW74 may occupy slot 1 of any Function Unit group on the shelf
(including Growth slots), and up to 40 100BASE-LX ports and 64
100BASE-TX ports are addressable when all Function Unit groups are equipped with LNW74 circuit packs. When the LNW74 circuit packs occupy slot 1 of a Function Unit group, slot 2 must be populated with an apparatus blank. The LNW74 may also be housed in the Growth slot
(G1), but only the optical ports are supported in the Growth slot.
365-372-300
Issue 8.0 September 2006
Ethernet Circuit Packs
1000BASE-X/100BASE-LX
(LNW78) RPR Ethernet interface
: Ethernet/SAN
This 8-port Ethernet interface provides 4-ports for short-reach and/or long-reach high-speed optical data transport at the rate of 1 Gb/s and
4-ports for optical 100BASE-LX transport at 100 Mbps. The first 4 ports (1-4) are for the GbE traffic (ports 3 and 4 are not available in
R6.0) and the second 4 ports (5-8) are for FE traffic. The LNW78 utilizes PTM optics, allowing you to equip additional ports as necessary. In R7.0, LNW78 adds support for the electrical
10/1000BASE-TX, electrical Ethernet PTM. This PTM may only occupy ports 1 and 2. The LNW78 also supports similar port, switching, and traffic management capabilities as the LNW70.
The LNW78 supports standards compliant RPR switching per IEEE
802.17. LNW78 will support one RPR instance in R6.0 and two in the future. The LNW78 provides two internal Virtual Concatenation Group
(VCG) WAN ports (will support 4 in the future) with a total capacity of
2.5 Gbps capacity for Ethernet RPR traffic (24 STS-1s in each direction).
Beginning in R7.0, LNW78 adds support for EoS services on VCG ports 17-22. VCGs 17-22 are not preceded by RPR IF modules residing between the Ethernet switch and GFP wrapper device. Therefore, traffic exiting the switch proceeds directly to the GFP wrapper device and then on to the VCG.
The LNW78 circuit pack supports STS-1, STS-3c, STS-12c cross-connect. Each VCG can have up to 24 tribs (maximum capacity of 48 virtual concatenated STS-1s) and the total available backplane link space is 24 STS-1s to Main-1 and 24 STS-1s to Main-2. The tribs may be assigned freely, all VCGs have access to all tribs.
Connections to the LNW78 are PTMs on the circuit pack faceplate.
Figure A-10 LNW78 RPR Ethernet Interface
1 2 3 4
7
8
1
RPR
IF 1
2
3
4
Ethernet
Switch
5
6
RPR
IF 2
GFP
GFP
GFP
GFP
GFP
VCG1
VCG2
VCG3
GFP VCG4
VCG17
VCG22
JK-E-17.eps
365-372-300
Issue 8.0 September 2006
A - 2 7
Ethernet Circuit Packs
: Ethernet/SAN
Legend:
1 External Ethernet Port
2 RPR IF
3 Generic Framing Procedure
4 Virtual Concatenation Group
For detailed information about Ethernet technologies, refer to
Prior to R7.0, LNW78 packs could only be placed in Slot 1 of any function group or growth slot in the shelf (A1-G1) and DMX supported a total add/drop capacity of 10 RPR GbE ports and 20 RPR FE ports if all slots were equipped with LNW78 circuit packs.
Beginning in R7.0, with the use of true 0x1 and the LNW59 VLF Main,
LNW78 can occupy slots 1 and 2 of and Function or Growth group.
This can increase the overall capacity of the system to 20 RPR GbE
(optical only) ports and 20 RPR FE (optical only) ports per shelf.
Certain restrictions apply when the LNW78 is equipped with electrical
PTMs. For a detailed description of circuit pack/slot equipage restrictions in 0x1, refer to Chapter 5.
Prior to Release 7.0 (and when VLF Mains are not used), if the LNW78 circuit packs occupy slot 1 of a Function Unit group, slot 2 must be populated with an apparatus blank.
100BASE-T/1000BASE-T Electrical PTM for the LNW78 (R7.0)
The LNW78 now supports a dual function electrical PTM that is provisionable for 100 or 1000 Mbps traffic. It conforms to the
IEEE802.3 standards for 100BASE-T and 1000BASE-T in its respective settings (IEEE802.3z and IEE802.3ab). Connectivity is provided for an RJ-45 Cat 5 cable and the PTM has a maximum span length of 100 meters.
The electrical PTM can only be installed in ports 1 and 2 of the
LNW78. Ports 5-8 are always reserved for 100BASE-LX optical Fast
Ethernet interfaces (ports 3 and 4 are not accessible in R7.0).
A - 2 8
365-372-300
Issue 8.0 September 2006
: Ethernet/SAN
Ethernet Transport
............................................................................................................................................................................................................................................................
Overview
A DMX network accepts Ethernet frames at an ingress port and transmits them out of one or more egress ports. The egress port(s) can be on the same network element or on a different network element. If it is on a different network element, Ethernet frames are transmitted over a SONET network. To transport an Ethernet frame across the SONET network, the Ethernet Frame is moved between a LAN port and the
SONET network. (Refer to the following figure.)
Figure A-11 Ethernet Transport Through DMX
SONET Network
SONET Interfaces
STS-1
Virtual
Concatenator
(ITU G.707)
STS-1/STS-3c
Virtual
Concatenator
(ITU G.707)
Switched
Service
GFP Mapper
(ITUG.7041)
VCG (WAN) Ports
GFP Mapper
(ITUG.7041)
Private Line
Service
Ethernet Switch
Ethernet
Circuit
Pack
LAN Ports
Physical Ethernet Transceiver
LAN Ports
MA-DMX-343
365-372-300
Issue 8.0 September 2006
A - 2 9
Ethernet Transport
: Ethernet/SAN
The following occurs to transport an Ethernet frame over a SONET network:
• The DMX accepts an Ethernet Frame at an ingress LAN Port.
• The Ethernet frame is accepted at an Ethernet switch’s LAN port for switched services, processed, and then transmitted out one or more of its LAN and/or VCG (WAN) port(s). For the LNW71 or
LNW74 10/100-PL circuit pack (which supports only nonswitched services), the Ethernet frame is sent directly to the
GFP mapper via a VCG port.
• The generic framing procedure (GFP) mapper encapsulates the
Ethernet frame into a GFP Frame.
• The Virtual Concatenator maps the Ethernet stream into one or more SONET tributaries (timeslots). This allows the network to carry traffic (Ethernet stream) at higher speeds than allowed by a single SONET tributaries (time slot). The group of virtually concatenated tributaries is referred to as a Virtual Concatenation
Group (VCG).
• The VCG is then placed on SONET tributaries and transmitted over the SONET network.
A - 3 0
365-372-300
Issue 8.0 September 2006
Ethernet Transport
: Ethernet/SAN
Generic framing procedure
(GFP)
Generic Framing Procedure (GFP) is used to encapsulate Ethernet frames for transport over a SONET network. The DMX uses frame-based GFP with the core header and no optional extension headers. The DMX Ethernet circuit packs don’t use Frame Check
Sequence (FCS), except for the LNW70 and LNW74 which have a provisionable FCS setting (on/off).
To encapsulate an Ethernet frame, the Ethernet preamble and Start of
Frame Delimiter (SFD) fields are removed from the frame. A Type header and check (tHEC) is added to the Ethernet frame creating a GFP payload. The GFP payload is then scrambled and a Core header is added. The GFP frame is then sent to the Virtual Concatenator. The following figure shows the format of a GFP frame.
Figure A-12 GFP Frame Format
Octets
7
A. Original Ethernet Frame
Preamble
Start of Frame Delimiter (SFD)
Destination Address (DA)
Source Address (SA)
Stacked VLAN TAG
1
802.1Q VLAN TAG
1
Length/Type
Octets
B. GFP Frame
2
Pay Load Indicator
2 cHEC
Type
2
2 tHEC
0 or 4
0 or 4
2
1
6
6
Data and Pad
4
Frame Check Sequence
Note:
1 - May not be present
2 - Up to 1536 for LNW66, LNW67, and LNW68 circuit packs
Up to 10240 for LNW71 circuit packs
Raw Ethernet Frame
Core
Header
Payload
Header
Payload
2
MA-DMX-344
365-372-300
Issue 8.0 September 2006
A - 3 1
Ethernet Transport
: Ethernet/SAN
The GFP fields are described in the following table.
Section
Core Header
Payload
Header
Payload
Field
Payload Indicator
(PLI)
Core Header Error
Control (cHEC)
Type
Type Header Error
Control (tHEC)
Description
Binary number representing the number of octets in the GFP payload.
CRC-16 checksum that protects the integrity of the contents of the Core Header.
The type of information contained in the
Payload field. The value is 01hex.
CRC-16 checksum that protects the integrity of the contents of the Type Field.
The raw Ethernet Frame (that is, the original
Ethernet Frame without the Preamble and SFD.
In the opposite direction when the GFP Mapper receives a GFP frame from the Virtual Concatenator, it removes the Core Header and, using the cHEC field, performs a Header Error Check. If the header is correct, the payload area of the GFP is then descrambled and the Type field and tHEC in the GFP header are checked for correctness. The
Ethernet frame is extracted and the Preamble and SFD are added.
The GFP mapper at the far end of the network inserts idle GFP frames when there are no Ethernet frames to send. The near end GFP Mapper discards any idle GFP frames it receives over the SONET network. The idle GFP frames are not forwarded to the Ethernet Switch. (The
LNW71 circuit pack does not contain an Ethernet switch.)
The GFP Mapper contains GFP queues that are used to store Ethernet frames while they are being processed.
The Generic Framing Procedure is defined in ITU-T G.7041/Y.1303 and ANSI T1X1.105 Sections 7.3.2 and 7.3.3.
A - 3 2
365-372-300
Issue 8.0 September 2006
Ethernet Transport
: Ethernet/SAN
Virtual concatenation
Virtual Concatenation is a standard inverse multiplex scheme for transporting a payload using multiple channels each of which has a lower capacity than the payload to be transported. It allows finer granularity in allocating the transport bandwidth than is available in standard contiguous concatenation (STS-3c, STS-12c, STS-48c etc.).
For example, an STS-1 tributary has a usable bandwidth of approximately 48.4 Mb/s. This is too slow for a 1 Gbits/s Ethernet stream. An STS-48c tributary has approximately 2.4 Gb/s which would waste 1.4 Gb/s of bandwidth if used to carry a 1 Gb/s Ethernet stream.
Using virtual concatenation, 21 STS-1 tributaries can be used providing an effective rate of approximately 1.02 Gb/s. Fewer STS-1 tributaries can be virtually concatenated to provide sub-rate (fractional rate) service.
The grouped SONET tributaries form a Virtual Concatenation Group
(VCG). A VCG is treated as a single logical serial byte stream whose payload capacity equals that of the sum of the payload capacities of the constituent SONET tributaries. The following figure shows a virtual concatenation group.
Figure A-13 Virtual Concatenation Group
1 Gb/s Ethernet
365-372-300
Issue 8.0 September 2006
Virtual
Concatenation
Up to 21 STS-1s
A Virtual Concatenation Group
MA-DMX-345
Individual tributaries in the VCG are independently transported through the SONET network. Only the initial and final SONET nodes perform the Virtual Concatenation. Since the VCGs are invisible to the intermediate SONET nodes, the intermediate nodes only need to transport normal SONET traffic and do not need to understand VCGs.
This allows the tributaries to be transported through equipment which does not handle VCGs.
A - 3 3
Ethernet Transport
: Ethernet/SAN
Differential Delay Buffers
Because the individual tributaries of a virtual concatenation group
(VCAT) can take different paths through the SONET network, they may experience different delays through the network.
The table below provides the differential delay buffers for each of the
Ethernet circuit packs.
Circuit Pack
Name
LNW63
LNW66/67/68
LNW71
LNW70/78
LNW73/73C
LNW74
Delay (in milliseconds)
100ms
16ms
32ms
50ms
120ms
64ms
SONET Transport
Ethernet circuit packs contain LAN ports and VCG ports. The LAN ports connect to external Ethernet equipment. The VCG ports connect to the OLIUs via Generic Framing (GFP) Mappers and Virtual
Concatenation Groups (VCGs).
The OLIUs contain the hardware that perform the SONET cross-connections and process traffic at the SONET tributary level.
They do not know about the embedded Ethernet frames or Virtual
Concatenation Groups.
Connections to the SONET network can be configured to provide
SONET layer protection. DMX supports three types of SONET protection: Unidirectional Path Switched Rings (UPSRs), Bidirectional
Line Switched Rings (BLSRs) and 1+1.
DMX supports transport of Ethernet frames on the following:
• UPSR tributaries
• Unswitched UPSR tributaries
• BLSR tributaries
• 1+1 point-to-point tributaries
• 0x1Sn tributaries
• Ethernet-to-Ethernet hairpin cross-connections
A - 3 4
365-372-300
Issue 8.0 September 2006
Ethernet Transport
: Ethernet/SAN
L1
V1
GFP VCG
Ethernet
Switch
V2
GFP VCG
L24
A. Fast Ethernet (LNW66)
Protected Tributaries
On protected tributaries, both rings carry the same traffic placed in the same tributaries (time slots), but in opposite directions in the case of
UPSR. UPSR protected cross-connections are provisioned as one
1wayPR cross-connections and two 1way cross-connections. BLSR protected cross-connections are provisioned using 1way cross-connections only.
Figure A-14 SONET Protected Cross-Connections
Main 1
OC-48 or
OC-192
OC-48 or
OC-192
Main 2
V1
GFP
L1
Ethernet
Switch
V2
V3
L2
V4
GFP
GFP
GFP
VCG
VCG
VCG
VCG
Main 1
OC-48 or
OC-192
OC-48 or
OC-192
Main 2
B. Gigabit Ethernet (LNW67 or LNW68)
L1
MAC
V1
GFP VCG
L24
MAC
V24
GFP VCG
C. Fast Ethernet (LNW71 or LNW74)
Main 1
OC-48 or
OC-192
OC-48 or
OC-192
Main 2
L1
MAC
V1
Main 1
GFP VCG
L4
MAC
L5
MAC
V4
V5
L8
MAC
V8
GFP
GFP
VCG
VCG
OC-48 or
OC-192
GFP VCG
OC-48 or
OC-192
Main 2
C. Gigabit/Fast Ethernet (LNW70)
L1--> L4= 1000BASE-X/ L5-->L8= 100BASE-FX
JK-E-3.eps
On LNW66, LNW67, and LNW68 circuit packs, only the odd numbered VCG ports can be used for SONET protected cross-connections because some of the hardware associated with the even numbered VCG ports is used to protect the odd number ports.
On the LNW63, LNW71, LNW74, and LNW70 circuit packs, all VCG ports can be used. When the LNW71 is in the STS-1 mode, up to 24 ports are supported, and up to 16 ports are supported in the STS-3c mode. For the LNW63, LNW70, and LNW74, circuit packs, all ports are supported regardless of STS mode. The picture above depicts the
LNW70 in private line mode. The LNW70 can also function in
365-372-300
Issue 8.0 September 2006
A - 3 5
Ethernet Transport
: Ethernet/SAN
A - 3 6
Unprotected Tributaries
In the case of UPSR unprotected tributaries, the two sides of the ring carry different traffic. Each VCG is connected to only one side of the ring.
1-way unswitched cross-connections provide unprotected SONET connections to Ethernet circuit packs on a UPSR. On the other hand, only 1way cross-connections are used on BLSR w/NUT. Each can be used to form two individual connections. One VCG is connected to
MAIN 1 while the other VCG is connected to Main 2. The following figure shows examples of the multipoint cross-connections provisioned by way of 1-way and 1-way unswitched cross-connects.
Figure A-15 Multi-point Cross-connections (unprotected)
L1
V1
GFP
Ethernet
Switch
V2
GFP
L24
A. Fast Ethernet (LNW66)
VCG
VCG
Main 1
OC-48 or
OC-192
OC-48 or
OC-192
Main 2
L1
MAC
GFP VCG
Main 1
OC-48 or
OC-192
L13
MAC
V13
GFP VCG
L24
MAC
GFP VCG
V24
C. Fast Ethernet (LNW71 in STS-1 Mode)
OC-48 or
OC-192
Main 2
L1
L2
L8
GFP
GFP
VCG
VCG
Main 1
OC-48 or
OC-192
L5
Ethernet
Switch
GFP
GFP
VCG
VCG
OC-48 or
OC-192
Main 2
E. RPR Gigabit/FastEthernet (LNW78)
L1--> L2= 1000BASE-X/ L5-->L8= 100BASE-FX
V1
L1
Ethernet
Switch
V2
V3
L2
V4
GFP
GFP
VCG
VCG
GFP VCG
GFP VCG
B. Gigabit Ethernet (LNW67 and LNW68)
Main 1
OC-48 or
OC-192
OC-48 or
OC-192
Main 2
L1
MAC
V1
GFP VCG
Main 1
L2
MAC
V2
L5
MAC
V5
L6
MAC
V6
GFP
GFP
VCG
VCG
OC-48 or
OC-192
GFP VCG
OC-48 or
OC-192
Main 2
D. Gigabit/Fast Ethernet (LNW70)
L1--> L2= 1000BASE-X/ L5-->L6= 100BASE-FX
L1
MAC
V1
GFP VCG
Main 1
L2
L3
MAC
MAC
V2
V3
GFP
GFP
VCG
VCG
OC-48 or
OC-192
L4
MAC
V4
GFP
F. Gigabit Ethernet (LNW63)
VCG
OC-48 or
OC-192
Main 2
JK-E-4.eps
365-372-300
Issue 8.0 September 2006
Ethernet Transport
: Ethernet/SAN
On the LNW66, LNW67, and LNW68, LNW71, LNW74, and LNW78 circuit packs, the odd number VCGs are paired with the next higher number VCG (for example, VCG 1 is paired with VCG 2, and VCG 3 is paired with VCG 4.) For example, VCG 2 must be connected to one
OLIU when VCG 1 is provisioned to be connected to the other OLIU.
Both cross-connections use the same SONET tributaries. The following figure shows an example of the VCG port pairing.
Figure A-16 Gigabit Multipoint Cross-Connections (Unprotected)
V1
L1
L2
Ethernet
Switch
V2
V3
V4
Main 1
SONET Ring
Main 2
V4
L1
V3
V2
Ethernet
Switch
L2
V1
Main 2 Main 1
VCG 1 Connect to far end VCG2
VCG 2 Connect to far end VCG1
MA-DMX-348
Multipoint cross-connections can either be used as two unprotected point-to-point connections or as part of a packet ring. If they are used as part of a packet ring, the Ethernet switch will process traffic received on one side of the packet ring before it is forwarded out the other side of the ring.
365-372-300
Issue 8.0 September 2006
A - 3 7
Ethernet Transport
: Ethernet/SAN
V1
L1
L2
Ethernet
Switch
V2
V3
V4
On the LNW63 and LNW70, any VCG can be connected to any OLIU.
The following figure shows an example of the VCG port pairing. As the figure below demonstrates, V1 in the shelf on the left could be connected to V1 in the shelf on the right. it is also possible to connect
VCGs in the same fashion as the packs described above. Below, this is shown by V3 being connected to V4, and V4 being connected to V3.
Figure A-17 LNW63 and LNW70 Gigabit Multipoint
Cross-Connections (Unprotected)
Main 1 Main 2
SONET Ring
Main 2
VCG 1 Connect to far end VCG1
VCG 2 Connect to far end VCG2
VCG 3 Connect to far end VCG4
VCG 4 Connect to far end VCG3
Main 1
V4
L1
V3
V2
Ethernet
Switch
L2
V1
MA-DMX-348_b
A - 3 8
365-372-300
Issue 8.0 September 2006
Ethernet Transport
: Ethernet/SAN
L1
L13
L24
MAC
MAC
MAC
L1
L9
L16
MAC
MAC
MAC
The LNW71 Ethernet circuit pack can operate in either STS-1 or
STS-3c mode. The pairing of its LAN ports for multipoint cross-connections is dependent on the mode. Traffic that is transmitted out of one LAN port is received on its paired LAN port. The following figure shows an example of multipoint cross-connections in the STS-1 and STS-3c modes.
Figure A-18 LNW71 Multipoint Cross-Connections (Unprotected)
GFP VCG
Main 1
GFP VCG
SONET Ring
Main 2
VCG GFP
VCG GFP
MAC
MAC
L13
L1
GFP VCG
Main 2 Main 1
VCG GFP
GFP VCG
GFP VCG
Note: In STS1 Mode
Port 1 connect to far end port 13
Port 13 connect to far end port 1
Main 1
SONET Ring
Main 2
VCG GFP
VCG GFP
MAC
MAC
MAC
L24
L9
L1
GFP VCG
Main 2
Main 1
VCG GFP
MAC
L16
Note: In STS3c Mode
Port 1 connect to far end port 9
Port 9 connect to far end port 1
MA-DMX-349
A multipoint cross-connection is made up of multiple 1-way or 1-way unprotected cross-connections.
365-372-300
Issue 8.0 September 2006
A - 3 9
Ethernet Transport
A - 4 0
: Ethernet/SAN
The following table shows the LNW71 circuit pack VCG port pairings in the STS-1 and STS-3c modes.
17
18
19
20
13
14
15
16
21
22
23
24
7
8
5
6
3
4
1
2
9
10
11
12
21
22
23
24
17
18
19
20
9
10
11
12
7
8
5
6
3
4
1
2
STS-1 Mode
Port Paired with Port...
Port
13
14
15
16
1
2
3
4
9
10
11
12
7
8
5
6
13
14
15
16
3
4
1
2
13
14
15
16
7
8
5
6
STS-3c Mode
Paired with Port...
9
10
11
12
365-372-300
Issue 8.0 September 2006
Ethernet Transport
: Ethernet/SAN
Ethernet-to-Ethernet Hairpin Cross-Connections
Ethernet-to-ethernet hairpin cross-connections are used to connect a circuit pack to another circuit pack within the same DMX. The cross-connection goes through either Main 1 or Main 2, but not over the SONET ring.
Hairpin cross-connections with an Ethernet circuit pack are used to either connect a VCG on that circuit pack with a VCG on another circuit pack or to connect a VCG with an OLIU located in a function or growth slot. Hairpin connections between VCG ports are used to combine Ethernet traffic from different cards before it is transmitted over a packet ring or out of a LAN port. The following figure shows examples of 1-way hairpin cross-connections between two Ethernet circuit packs.
Figure A-19 Ethernet-to-Ethernet Hairpin Cross-Connections
LNW66 LNW67/LNW68
L1
Main 1
Ethernet
Switch
L24
V1
V2
GFP
GFP
VCG
VCG
OC-48 or
OC-192
OC-48 or
OC-192
Main 2
GFP
GFP
GFP
GFP
VCG
VCG
VCG
VCG
V1
V2
Ethernet
Switch
V3
L1
L2
V4
A. 2 Way Cross-Connection
MA-DMX-353
365-372-300
Issue 8.0 September 2006
A - 4 1
Ethernet Transport
: Ethernet/SAN
The table below details the support of 1way cross-connections between
Ethernet packs. For hairpins between packs on the same shelf, only
1way cross-connections are used.
Table A-1 1way Cross-Connection Support
LNW63
LNW64
LNW66
LNW67/68
LNW70
From
LNW71
LNW73/73C
LNW74
LNW78
(RPR VCGs 1&2)
LNW78
(EoS VCGs 17-22)
To
LNW63, W64, LNW66,
LNW67/68, LNW70,
LNW71, LNW74
LNW63, W64, LNW66,
LNW67/68, LNW70,
LNW71, LNW74
LNW63, LNW64,
LNW67/68, LNW70
LNW63,LNW64, LNW66,
LNW67/68, LNW70
LNW63, LNW64, LNW66,
LNW67/68, LNW70,
LNW71, LNW74
LNW70, LNW63 LW64
LNW73/73C
LNW70, LNW63, LNW64
LNW78
LNW63,LNW64, LNW66,
LNW67/68, LNW70,
LNW71, LNW74
A - 4 2
365-372-300
Issue 8.0 September 2006
Ethernet Transport
: Ethernet/SAN
Ethernet LAN/VCG port density
The Ethernet Switch, also referred to as a Media Access Control
(802.1D MAC) bridge, processes the Ethernet frames and handles
Virtual LANs, frame priority, frame forwarding, and switching functions. The ports on the customer’s side of the switch are referred to as LAN ports, and the ports on the SONET side are referred to as VCG or WAN Ports.
The following table shows the number of LAN and VCG ports on the
Ethernet circuit packs.
Circuit Pack
Name
LAN Port
Line Rate
LNW63
LNW64
1 Gbps
1 Gbps
4
8
LNW66 10/100 Mbps 24
LNW67, LNW68 1 Gbps 2
Number of Ports
LAN
(Boundary)
VCG
(Interior)
4
8
2
4
LNW70
LNW71
LNW74
LNW78
(RPR)
LNW78
(EoS)
1
1 Gbps/ and
100 Mbps
8
24 (STS-1 Mode)
10/100 Mbps
16 (STS-3c Mode)
10/100 Mbps 24
1 Gbps/ and
100 Mbps
1 Gbps/ and
100 Mbps
6
6 (LAN)
6
2
(VCG)
8 (Private Line Mode)
32 (Switched Mode)
24 (STS-1 Mode)
16 (STS-3c Mode)
24
2 (Switched Mode)
Maximum
Capacity of a VCG Port
1 Gbps
1 Gbps
1 Gbps
1 Gbps
2.5 Gbps
100 Mbps
100 Mbps
1.2 Gbps
1.2 Gbps
Notes:
1. QoS provisioning on EoS VCGs in transparent mode, a new feature for
R7.0, allows LNW70 VCGs i transparent mode to be provisioned as either interior or boundary.
2. In R7.0, LNW78 adds support for EoS service on VCGs 17-22. EoS VCG ports are seen as boundary ports, not interior as with other packs. VCG ports
1-4 remain reserved for RPR service (VCGs 3 and 4 not available in R7.0).
365-372-300
Issue 8.0 September 2006
A - 4 3
Ethernet Transport
: Ethernet/SAN
Virtual LANs (VLANs)
A virtual LAN (VLAN) is a logical grouping of LAN ports, possibly spread across multiple DMX nodes, that act as if they comprise a single
LAN. Since a physical LAN can be associated with multiple virtual
LANs, VLANs can be used to segregate traffic across a network.
VLANs can be used to segregate different types of traffic for a single customer or to separate traffic belonging to multiple subscribers.
VLANs operate at the Ethernet (MAC) Layer. This allows different
VLANs to be carried on the same physical media and hides the VLANs from higher-level protocols (for example, TCP and IP). The higher-level protocols treat each VLAN as if it was a separate physical
LAN. VLAN-aware Ethernet Switches will forward VLAN traffic only on ports assigned to that VLAN. A port can be part of several VLANs and a VLAN can be assigned to several ports.
A frame’s VLAN can be assigned either by the subscriber’s equipment or by network equipment. User equipment specifies the VLAN by including a VLAN Tag in the frame. DMX determines a frame’s
VLAN either from the frame’s existing VLAN Tag or by the default
VLAN ID assigned to the frame’s ingress port. DMX can be provisioned to drop frames that do not contain a tag.
A - 4 4
365-372-300
Issue 8.0 September 2006
Ethernet Transport
: Ethernet/SAN
VLAN Tags
VLAN Tags are located in the Ethernet Header. The following figure shows the format of Ethernet frames without a VLAN Tag, frames with a VLAN Tag, and the format of the VLAN Tag.
Figure A-20 Ethernet Frame Format
7 Bytes
1 Byte
6 Bytes
6 Bytes
2 Bytes
A. Ethernet Frame without VLAN Tag
Preamble
Start of Frame Delimiter
Destination Address
Source Address
Length/Type
46-1500 Bytes
Data and Pad
4 Bytes
Frame Checksum Sequence
B. Ethernet Frame with a VLAN Tag
Preamble
Start of Frame Delimiter
Destination Address
Source Address
VLAN Tag
Length/Type
Data and Pad
Frame Checksum Sequence
7 Bytes
1 Byte
6 Bytes
6 Bytes
4 Bytes
2 Bytes
46-1500 Bytes
4 Bytes
C. Details of a VLAN Tag
TPID (16 Bits)
TPID
User_priority
CFI
VLAN ID
User_priority (3 Bits) CFI (1 Bit) VLAN ID (12 Bits)
Tag Protocol ID (Ethertype)
User Priority Information
Canonical Format Indicator
VLAN Identity (001-FEE hex
)
MA-DMX-354
VLAN Tags can be generated by either user equipment or a switch. If a switch adds a VLAN Tag to a frame, it must also recalculate the frame’s Checksum (FCS). In Release 1.1 and later releases, DMX supports provisioning of 4093 VLAN IDs within the range of 1-4093.
Prior to Release 1.1, DMX supports provisioning of 270 VLAN IDs within the range of 1-4093. Additional information about VLAN tags can be found in IEEE 802.1Q.
365-372-300
Issue 8.0 September 2006
A - 4 5
Ethernet Transport
: Ethernet/SAN
Stacked VLANs (VLAN Transparency)
In order to allow carriers to administer VLAN IDs independent of their subscribers, DMX can be provisioned to add a second VLAN Tag to
Ethernet Frames. This tag, referred to as a Port Tag or Stacked VLAN
Tag, can be used by the service provider to identify and segregate customer (subscriber) traffic. The following figure shows the format of an Ethernet frame that contains stacked VLAN tags.
Figure A-21 Ethernet Frame Format with Stacked VLAN Tags
A. Ethernet Frame with Only a Port Tag
7 Bytes
1 Byte
Preamble
Start of Frame Delimiter
6 Bytes
6 Bytes
4 Bytes
2 Bytes
46-1500 Bytes
4 Bytes
Destination Address
Source Address
Port (VLAN) Tag
Length/Type
Data and Pad
Frame Checksum Sequence
B. Ethernet Frame with Both a VLAN Tag and Port Tag
Preamble
Start of Frame Delimiter
7 Bytes
1 Byte
Destination Address
Source Address
Port (VLAN) Tag
6 Bytes
6 Bytes
4 Bytes
4 Bytes
802.1Q VLAN Tag
Length/Type
Data and Pad
Frame Checksum Sequence
2 Bytes
46-1500 Bytes
4 Bytes
C. Details of a VLAN or Port Tag
TPID (16 Bits) User_priority (3 Bits)
TPID
User_priority
CFI
VLAN ID
Tag Protocol ID (Ethertype)
User Priority Information
Canonical Format Indicator
VLAN Identity (001-FEE hex
)
CFI (1 Bit) VLAN ID (12 Bits)
MA-DMX-355
The port tag is formatted according to IEEE 802.1Q except:
• The frame is given a provisioned Ethertype (TPID). The TPID became provisionable on DMX in Release 4.0. In Releases prior to Release 4.0, the TPID parameter is not provisionable and has a proprietary value of FFFFhex.
• The Canonical Format Indicator (CFI) field is set to 0
• A Customer ID is encoded into VLAN ID field and can contain a value in the range of 1-4093.
A - 4 6
365-372-300
Issue 8.0 September 2006
Ethernet Transport
: Ethernet/SAN
DMX is capable of handling frames with multiple layers of VLAN tags; ultimately the limit is that frames greater than 1536 bytes are rejected as too large. When processing VLAN tags, DMX only looks at the outermost tag (that is, the one that most closely follows the Source
Address) that it recognizes. Recognition of a tag is based on the TPID value. In 802.1Q mode, the expected TPID value is 8100hex. In transparent mode, the expected TPID value is provisioned by the user, with the default value being FFFFhex. Legal provisioned values for
TPID are between 0601hex and FFFFhex. These TPID values are also used to identify any tags inserted by DMX.
Based on provisioning at the network ingress and egress points, it is possible for an Ethernet frame to enter and leave the network with a different number of VLAN tags
.
Priorities
Each Ethernet frame is assigned a priority level. The priority level can be based on a field in a VLAN Tag or a default priority assigned to the frame’s ingress port. If an ingress port is provisioned with a default priority, the default priority will take precedence over the priority field in the VLAN tag.
A VLAN Tag contains a three-bit user_priority field. This allows higher priority frames to be processed at a faster rate than lower priority frames. For the LNW66, LNW67, LNW68 packs, DMX maps the three-bit user priority field to two priority levels. These circuit packs contain two priority queues. Ethernet frames are processed using an 8:1 weighted round robin queue service algorithm. The LNW70 pack contains 4 priority queues. For more information about the
LNW70, refer to the section of this Appendix entitled
365-372-300
Issue 8.0 September 2006
A - 4 7
Ethernet Transport
A - 4 8
: Ethernet/SAN
5
6
3
4
7
0
1
2
For tagged frames, the following table shows the mapping between values in the user priority field and the priority queues for all of the
Ethernet packs except the LNW70. An Ethernet port can be provisioned to drop untagged frames, or add a VLAN tag containing the port’s default user priority field value of 0 (low) or 7 (high).
VLAN Tag User Priority
Field Value
Queues
Low
Low
Low
Low
High
High
High
High
For tagged frames, the following table shows the default mapping between values in the user priority field and the priority queues for the
LNW70 when the pack is in no traffic management mode.
5
6
7
3
4
1
2
0
VLAN Tag User Priority
Field Value
(3)
(4)
(4)
(1)
(1)
(2)
(3)
Queues
(1=lowest --> 4=highest)
(2)
For more information about frame priority rules, refer to “802.1Q
VLAN mode” (A-80) and to the section entitled
365-372-300
Issue 8.0 September 2006
Ethernet Transport
: Ethernet/SAN
Ethernet Bridge/Switch
This section pertains to the LNW66, LNW67, LNW68, LNW70, and
LNW78.
An Ethernet bridge moves a frame from an ingress port to an egress port(s). It will not forward a frame if the frame contains errors or has the same source and destination addresses.
The bridge looks up the destination MAC address/VLAN ID combination in the address table. If the MAC address is found, the bridge sends the frame to the port(s) found in the address table. If the
MAC address is not found, the bridge sends the frame to all ports associated with the VLAN ID (except the originating port).
Enhanced RPR bridging, supported by the LNW78, will look-up the
Remote RPR station address for the purpose of spatial reuse.
All multicast and broadcast frames are broadcasted including spanning tree BPDUs.
The size of the address table is 8K entries for the LNW66, 67, and 68.
The size of the address table is 256K for the LNW70 and LNW78 packs. Each combination of MAC Address/VLAN ID is one entry.
Entries will be removed if they are not used within 300-600 seconds
(5-10) minutes. During a topology change, they will be deleted as soon as the change is detected.
For more information on Bridging and Steering in RPR (LNW78 only), please refer to
“Ethernet Transport via RPR” (3-31) .
365-372-300
Issue 8.0 September 2006
A - 4 9
Ethernet Transport
A - 5 0
: Ethernet/SAN
Virtual Switch
The single physical Ethernet switch on an LNW66/67/68/70 Ethernet circuit pack can be logically divided into multiple virtual switches. A virtual switch, identified by an id number between 1 and 4095 (between
1 and 16 on LNW70), consists of a collection of LAN and VCG ports.
Any VLANs and spanning tree groups associated with the ports also become associated with the virtual switch. Each LAN port, VCG port,
VLAN ID and spanning tree group id can only be associated with one virtual switch per Ethernet circuit pack. On the LNW66/67/68 each
VLAN ID can only be associated with one virtual switch. On the
LNW70, the same VLAN ID can be associated with many virtual switches and each virtual switch has its own VLAN ID. A minimum of one virtual switch must be created on the LNW66/67/68/70 Ethernet circuit pack in order to provision VLANs and spanning tree groups when in 802.1Q or Transparent Tagging mode. When a port is removed from a virtual switch it returns to its default parameters. Virtual switches are not used in Private Line mode or on LNW71 and LNW74 circuit packs.
The following figure shows one possible assignment of LAN ports and
VCG ports into virtual switches. The figure shows one physical switch that is divided into two virtual switches. Virtual switch 1 supports a packet ring configuration encompassing LAN port 1 and VCG ports 1 and 2. Virtual Switch 2 supports a point-to-point configuration encompassing LAN port 2 and VCG ports 1 and 2. Ethernet traffic will not be allowed to cross between the virtual switches.
Figure A-22 Virtual Switches
LAN
Service 1
Virtual SW 1
LAN
Service 1
LAN
Service 2
L1
2
Packet Ring
V3
V4
V1
V2
GFP
GFP
GFP
GFP
VCG
VCG
VCG
VCG
Point-to-point Protected
UPSR
Virtual SW 2
LAN
Service 2
MA-DMX-356
365-372-300
Issue 8.0 September 2006
Ethernet Transport
: Ethernet/SAN
Spanning tree protocol
(STP)
Spanning tree protocol (STP) provides a protection scheme for
Ethernet packet transmission as a by-product of its primary function of eliminating loops in Ethernet networks. This protection is independent of any SONET-level protection mechanisms such as UPSR switching.
In fact, undesirable interactions can occur if both protection mechanisms are used, so it is recommended that spanning tree protocol be used only in configurations with no SONET protection.
Loops can arise within Ethernet networks as a result of multiple paths between a source and a destination. The spanning tree protocol identifies links that must be blocked to ensure that no such multiple paths can exist. Any link failure in the resulting network triggers the spanning tree protocol to re-analyze the network and identify a new set of blocked links that provide full connectivity with no duplicated paths.
It is this reconfiguration in response to failures that constitutes the packet layer protection mechanism.
How it Works
Spanning tree works as follows:
1.
Initially, every node in the group thinks it is the root node.
2.
Configuration BPDUs are sent from each node to determine the most economical route from each node to the root node.
3.
As information about the network becomes clear, one node is designated the root node; from this node, the distance to any point in the network may be measured.
4.
Once the network has become clear, some ports are blocked so that there are no loops in the network and so that the network provides the most efficient paths from the root to the nodes.
This effectively creates a tree structure for the network.
365-372-300
Issue 8.0 September 2006
A - 5 1
Ethernet Transport
: Ethernet/SAN
5.
If an active link fails, the network is reconfigured so that previously blocked links can be used for traffic.
Figure A-23 Spanning Tree
5
3
2
7
Path 1
4
6
1
Root bridge nc-dmx-095
Legend:
Active Links 1 to 2; 2 to 3; 3 to 5; 1 to 6; 6 to 4; 4 to 7
Inactive Links 5 to 7
X Indicates a blocked port (frame forwarding is disabled)
Important!
The configuration provides the least (most efficient) path from each node to the root. The configuration also provides only one path between any two nodes.
Reconfiguration
If one of the active links is broken, the network reconfigures to activate the inactive link. For example, if the link between 2 and 3 is broken, the link between 5 and 7 would be enabled.
Migration to 802.1W Rapid Spanning Tree Protocol
Prior to Release 2.0, DMX implemented the 802.1D version of the spanning tree protocol. In Release 2.0 and later releases, DMX migrated to the 802.1W rapid spanning tree protocol (RSTP) and made
A - 5 2
365-372-300
Issue 8.0 September 2006
Ethernet Transport
: Ethernet/SAN
some other spanning tree enhancements. The changes are summarized in the following:
• Faster Failure Detection - DMX uses SONET-layer failure detection to trigger packet-layer (spanning tree) reconfiguration, so packet-layer reconfiguration starts within a few milliseconds after a failure rather than several seconds later.
• IEEE 802.1W Rapid Reconfiguration - DMX supports this new standard packet-layer restoration protocol, which uses new messages between spanning tree protocol entities to significantly reduce convergence time.
• Spanning tree version interworking - Each DMX node will query its Ethernet link partners to determine if they are capable of running the 802.1W rapid spanning tree protocol. If so, the
802.1W protocol will be used. If not, the DMX will fall back to running the 802.1D version of spanning tree protocol.
• Enhanced STP configuration reports and controls - Together with
802.1W, these enable support for much larger networks than are supported with IEEE 802.1D Spanning Tree Protocol.
365-372-300
Issue 8.0 September 2006
A - 5 3
Ethernet Transport
: Ethernet/SAN
Spanning Tree on LAN ports
DMX added support for spanning tree on the LAN (customer facing) ports in R6.0. STP on LAN ports ensures that single LAN interconnects are protected. Because redundant LAN interconnects create loops, STP manages the loops. In R6.0, STP is supported on the LAN ports of the
LNW70 only.
Both LAN ports and VCGs can belong to STP groups. A LAN port can belong to only one STP group at a time. Beginning in R6.0, the BDPU
VLAN ID becomes provisionable. VLAN IDs are provisionsable on a per-port basis. Prior to R6.0 all VLAN IDs were #4094
LAN based STP works exactly as described in the section above. The figure below depicts STP functioning on the customer side of a DMX with LNW70 circuit packs. The nodes marked A and B represent remote Ethernet switches or similar CPEs.
Figure A-24 Spanning Tree on LAN ports
A
2
1
Root bridge
B
Path 1
JK-E-14.eps
Legend:
Active Links 1 to 2; 1 to B; B to A
Inactive Links A to 2
X Indicates a blocked port (frame forwarding is disabled)
A - 5 4
365-372-300
Issue 8.0 September 2006
Ethernet Transport
: Ethernet/SAN
Link Aggregation on
LNW70 LAN ports
DMX supports link aggregation on any two LNW70 LAN ports of the same rate (i.e. 100 or 1000 Mbps), operating in switched mode. In
R7.0, the two ports comprising a LAG must be located on the same pack.
Link aggregation can also be used for facility protection on LNW70
LAN ports.
Bandwidth increase/decrease
Ordinarily, multiple Ethernet links between two bridges form loops
(unless a spanning tree blocks all but one) so they can’t be used to increase bandwidth. Link Aggregation causes defined groups of links to be treated as a single logical link, making multiple LAN ports appear as one. In this way, Bandwidth may be increased without requiring an upgrade to a higher rate link.
Facility protection
Link aggregation can also remove failed links automatically, thereby providing a means of facility protection. When a link fails, traffic is shifted to the remaining links in that Link Aggregation Group (LAG).
More links than are needed can be added to the group and each is active until it fails (similar to utilizing LCAS protection for SONET tributaries).
Link aggregation control protocol
Link Aggregation is specified in IEEE 802.3 clause 43, formerly specified in 802.3ad. The LNW70 can be configured to either use this standard protocol to control link aggregation (which negotiates with the equipment at the other end of the link) or to simply force aggregation without a control protocol.
365-372-300
Issue 8.0 September 2006
A - 5 5
Ethernet Transport
A - 5 6
: Ethernet/SAN
General link aggregation rules
Link aggregation is available for LAN ports on the LNW70 pack beginning in R7.0 and behaves along the following basic guidelines:
• Available for LAN ports on the LNW70 in switched mode only
• Maximum of 4 LAGs per pack, 2 ports per LAG, and 8 LAGs per function unit or growth group. There are 8 ports on each LNW70 pack.
• The two ports in a LAG must be on the same pack, and be functioning at the same rate (i.e. 100 or 1000 Mbps).
• All links in a LAG are in-service until they fail. Standby links, providing 1x1 SONET-style protection, are a future feature.
• When a LAG is created, the attributes (VLAN, virtual switch, and other L2 provisioning) of the first port used to establish the LAG are transferred to the LAG. When the second port is added, it then inherits the L2, VLAN and Virtual Switch (VS) characteristics of the LAG for the time it remains a member. It can not be part of a
VS or have any VLAN provisioning when added.
-- Both member ports can also be added simultaneously and DMX recognizes a parameter that distinguishes the "Lead Port". The
LAG (and by association, the other port in the LAG) inherits the
L2, VLAN, and VS attributes of the Lead Port.
• When a port is removed from a particular LAG, it is no longer a member of a VS.
• A port must have L2 and VS provisioning in order for a port to be used as the Lead port or to establish a LAG (VLAN provisioning not required). This information is then transferred to the LAG once it’s created.
• The last port/member of a LAG cannot be removed from the
LAG; the LAG itself must be deleted. The last port/member of a the inherits the LAG’s L2, VLAN, and VS attributes.
-- If the last member in the LAG was the first member added originally, and if there were no subsequent changes to L2 and
VLAN attributes, the port will effectively revert to it’s original state when the LAG is deleted.
-- If the last member/port in the LAG was not the first added initially it will inherit the characteristics of the LAG rather than reverting to its original state.
365-372-300
Issue 8.0 September 2006
Ethernet Transport
365-372-300
Issue 8.0 September 2006
: Ethernet/SAN
Link Aggregation Example
The figure below depicts link aggregation on two LNW70 LAN ports functioning at 100Mbps. The top portion of the figure shows two ports receiving separate 100 Mbps inbound flows. The bottom portion depicts the same two flows being equally split across the two outbound ports in the LAG. In this example, no failure has occurred and both ports comprising the LAG are in-service.
Traffic entering incoming ports is aggregated into a LAG. While both ports are in-service, outgoing traffic is split between working ports.
Figure A-25 Link aggregation at 100 Mbps
(all ports in-service)
Link Aggregation Group (LAG)
100 Mb
100 Mb
Up to
200 Mbps
LNW70
Link Aggregation Group (LAG)
LNW70
100 Mb
100 Mb
200 Mbps per conversation
MA-DMXAPG-044
The instance pictured above represents the ideal case, in which there are at least 2 flows, each a maximum of 100Mbps. In this case they can be equally split over the two ports comprising the LAG. The ability to split the two flows across multiple ports also depends on the distribution of MAC/IP addresses.
Link aggregation employs an algorithm that assigns traffic to member ports to prevent misreading. A given flow can be assigned to only one port and cannot be split across multiple ports in the same LAG. To increase flexibility, DMX allows a flow to be defined by either a MAC source and destination address pair or an IP source and address pair.
The algorithm uses the XOR of the least significant bits of the address pairs to assign a port/link. Therefore, the actual load balancing achieved depends on the distribution of MAC/IP addresses.
A - 5 7
Ethernet Transport
: Ethernet/SAN
Link aggregation transparency
Link aggregation allows multiple physical links between Ethernet switches to be treated as a single link. This provides for more bandwidth between the switches than can be transmitted over a single
Ethernet port and it can provide protection from a cable, Ethernet port, or Ethernet circuit pack failure.
While R7.0 supports link aggregation, the DMX also supports link aggregation transparency in both R7.0 and previous releases. As shown in the following figure, this allows the attached equipment to use link aggregation without participation by the DMX provisioning.
Figure A-26 Link Aggregation
External
Ethernet
Equipment
(Device)
Metropolis
®
DMX
SONET Network
Metropolis
®
DMX
Link
Aggregation
Group
LAN Ports
Located on 1
Or More
Circuit Packs
LAN Ports
Located on 1
Or More
Circuit Packs
Link
Aggregation
Group
External
Ethernet
Equipment
(Device)
Ethernet Links
(10 or 100 or 1000 Mbps)
Ethernet Links
(10 or 100 or 1000 Mbps)
Link Aggregation Group (e.g. Links that are aggregated together)
MA-DMX-357
The figure shows two Ethernet devices running link aggregation interconnected via Ethernet circuit packs and a SONET Network. The
DMX shelves and the SONET network are invisible to the two Ethernet devices. The Ethernet traffic is transparently transferred between the external devices. Link aggregation is typically implemented using two dedicated unprotected point-to-point links (Ethernet Private Line
Service) for each pair of external ports.
Link aggregation transparency requires a default VLAN ID tag or port tag in 802.1Q and Transparent Tagging mode. If a default VLAN or port tag is not specified at the port, the link aggregation messages are dropped.
A - 5 8
365-372-300
Issue 8.0 September 2006
Ethernet Transport
: Ethernet/SAN
Flow control
This section describes how DMX controls the flow of Ethernet traffic.
DMX supports the following types of flow control:
• Local flow control
• End-to-end flow control
Local Flow Control (Ingress Traffic Direction)
If the external equipment delivers Ethernet frames to the Ethernet circuit pack faster than they can be delivered across the network, the data buffers in the Ethernet circuit pack fill up. When the data buffers reach the flow control threshold, the Ethernet circuit pack initiates flow control. On full duplex links, the Ethernet circuit pack issues a flow control request to the external equipment, requesting that the flow of frames be suspended. On half duplex links, the JAM signal is used to stop all traffic. The flow control request is repeated periodically, or the
JAM signal continuously generated until the buffers empty sufficiently.
(Refer to the following figure.)
Figure A-27 Local Flow Control of Ingress Traffic
Metropolis
DMX 1
®
Metropolis
DMX2
®
External
Equipment 1
Data
Ethernet
Link
Ethernet
Circuit Pack
Buffer
SONET
Sub Rate
Ethernet
Circuit Pack
Flow
Control
Request
When data rate from External Equipment 1 exceeds SONET bandwidth, DMX 1 will invoke flow control toward External Equipment 1
External
Equipment 2
MA-DMX-358
Note that this local flow control mechanism is concerned only with congestion (full packet buffers) at the local DMX. If the DMX at the other end of the SONET network is unable to deliver the Ethernet frames to the attached external equipment due to flow control conditions there, that does not directly affect the local flow control operation at the ingress DMX.
365-372-300
Issue 8.0 September 2006
A - 5 9
Ethernet Transport
: Ethernet/SAN
Local Flow Control (Egress Traffic Direction)
If the local Ethernet circuit pack attempts to deliver Ethernet frames to the attached external equipment faster than the external equipment can accept them, the external equipment may initiate flow control. On full duplex links, the external equipment issues a flow control request to the
Ethernet circuit pack requesting that the flow of frames be suspended.
On half duplex links, the JAM signal is used to stop all traffic. (Refer to the following figure.)
Figure A-28 Local Flow Control of Egress Traffic
2. A Flow Control
Request is generated by External Equipment 1
3.
On receiving the Flow Control
Request, the DMX 1 stops sending
Ethernet Frames to External Equipment 1
Metropolis
®
DMX1
Metropolis
DMX 2
®
External
Equipment 1
Flow
Control
Request
Ethernet
Link
Ethernet
Circuit Pack
Buffer
SONET
Sub Rate
Ethernet
Circuit Pack
Ethernet
Link
External
Equipment 2
4. When the buffers are full, additional Ethernet Frames are dropped
1. Data from
External
Equipment 2
A Flow Control Request generated by External Equipment 1 is handled in the local Ethernet Circuit Pack
DataFrames generated by External Equipment 2, will be stored in a buffer in DMX
tend
Any frames received after the buffer is filled will be dropped
1
MA-DMX-359
This causes the Ethernet circuit pack to stop sending Ethernet frames to the external equipment for the time requested in the flow control request. During this time, Ethernet frames accumulate in the packet buffers in the Ethernet circuit pack. Once these buffers fill completely, further Ethernet frames arriving from the SONET network for the egress Ethernet port are dropped.
A - 6 0
365-372-300
Issue 8.0 September 2006
Ethernet Transport
: Ethernet/SAN
365-372-300
Issue 8.0 September 2006
End-to-End Flow Control
If the external equipment at the destination of an Ethernet connection cannot handle the rate of traffic being sent to it, it may be desirable to apply back pressure across the network to slow down the external source of the Ethernet traffic. This cross-network back pressure can only work well, however, when the source of the traffic can be identified unambiguously. Only the Ethernet Private Line Service offers this opportunity; thus, it is the only service that supports
End-to-End Flow Control.
End-to-End Flow Control (LNW66, LNW67, LNW68 Circuit Packs)
With end-to-end flow control, flow control requests that are received by the LNW66, LNW67, and LNW68 Ethernet circuit packs at the egress point of the network, are regenerated during congested conditions by the Ethernet circuit pack at the ingress point of the network and transmitted to the originating external equipment.
Figure A-29 End-to-End Flow Control (LNW66, LNW67, LNW68)
2. A Flow Control
Request is initiated by
External Equipment 1
3. When the buffer reaches the Flow Control
Threshold, DMX 1 transmits a Flow Control
Request towards the
External Equipment 2
4. In Response to the
Flow Control Request,
DMX 2 stops transmitting
Frames toward DMX1
6. External Equipment 2 stops sending frames in response to the Flow
Control request
Metropolis
®
DMX 1
External
Equipment 1
Flow
Control
Request
Ethernet
Link
Ethernet
Circuit Pack
Buffers
SONET
Metropolis
®
DMX 2
Ethernet
Circuit Pack
Buffers
Flow
Control
Request
Ethernet
Link
External
Equipment 2
3a. When the queue is full additional Ethernet Frames are dropped
1. Data from
External
Equipment 2
5. When the ingress queue is full, a Flow control Request is transmitted to External Equipment 2
Flow Control Requests generated by External Equipment 1
Data Frames received in DMX 1 from External Equipment 2 will be stored in a latency buffer
Any Frames received in DMX1 after the latency buffer is full will be dropped
®
DMX = Metropolis DMX Access Multiplexer
MA-DMX-360
While waiting for the originating external equipment to receive and process the flow control request, the destination Ethernet circuit pack
A - 6 1
Ethernet Transport
: Ethernet/SAN
buffers Ethernet frames received over the SONET network. If the buffer fills before the frame flow stops, the excess frames will be discarded.
End-to-End Flow Control (LNW71/70/63 Circuit Pack)
The LNW71/70/63 circuit pack implements the following changes intended to improve the frame loss behavior of end-to-end flow control.
• When provisioned for end-to-end flow control, the LNW71/70/63 circuit pack sends a flow control request across the SONET network immediately upon receiving a flow control request from external equipment.
• The LNW71/70/63 circuit pack contains large latency buffers to hold data while waiting for far-end equipment to respond to end-to-end flow control requests. (Refer to the following figure.)
Figure A-30 End-to-End Flow Control (LNW71/70/63)
2. A Flow Control
Request is initiated by
External Equipment 1
Metropolis
®
DMX 1
External
Equipment 1
Flow
Control
Request
Ethernet
Link
Ethernet
Circuit Pack
Latency
Buffer
200KB for
LNW71
2MB for
LNW70
10MB for
LNW63
SONET
Metropolis
®
DMX 2
3b. External Equipment 2 reacts to the to
Flow Control request
Ethernet
Circuit Pack
Flow
Control
Request
Ethernet
Link
External
Equipment 2
Buffer
1. Data from
External
Equipment 2
A - 6 2
3a. Large latency buffer supports
1000 miles
Flow Control Request is generated by External Equipment 1
Flow Control Request is sent immediately to External Equipment 2
Data Frames received from External Equipment 2 will be stored in a large latency buffer
External Eqipment 2 stops sending data in time for a loss-less transmission
DMX = Metropolis
®
DMX Access Multiplexer
JK-E-6
After a flow control request is received, the LNW71/70/63 circuit pack buffers frames instead of sending them to the equipment that generated
365-372-300
Issue 8.0 September 2006
Ethernet Transport
: Ethernet/SAN
the flow control request. Each port has its own latency buffer. A latency buffer can store 16ms of traffic that allows the equipment to be about 1000 miles apart (2000 miles round trip).
End-to-End Flow Control (LNW74 Circuit Pack)
The LNW74 circuit pack implements the following changes intended to improve the frame loss behavior of end-to-end flow control.
• When provisioned for end-to-end flow control, the LNW74 circuit pack sends a flow control request across the SONET network immediately upon receiving a flow control request from external equipment.
• The LNW74 circuit pack does not buffer data while waiting for far-end equipment to respond to end-to-end flow control requests.
Data is transmitted to the client.(Refer to the following figure.)
Figure A-31 End-to-End Flow Control (LNW74)
2. A Flow Control
Request is initiated by
External Equipment 1
Metropolis
®
DMX 1
External
Equipment 1
Flow
Control
Request
Ethernet
Link
Ethernet
Circuit Pack
LNW74
SONET
Metropolis
®
DMX 2
3b. External Equipment 2 reacts to the to
Flow Control request
Ethernet
Circuit Pack
Buffer
Flow
Control
Request
Ethernet
Link
External
Equipment 2
1. Data from
External
Equipment 2
Flow Control Request is generated by External Equipment 1
Flow Control Request is sent immediately to External Equipment 2
External Eqipment 2 stops sending data in time for a loss-less transmission
®
DMX = Metropolis DMX Access Multiplexer
JK-E-7
365-372-300
Issue 8.0 September 2006
A - 6 3
Ethernet Transport
: Ethernet/SAN
Flow Control Provisioning (LNW66, LNW67, LNW68 Circuit Packs)
A combination of flow control settings on the LNW66, LNW67 and
LNW68 circuit pack LAN ports and VCGs determine how flow control operates.
The following table shows the flow control settings for the LNW66,
LNW67, and LNW68 circuit packs.
LAN Port
Flow
Control
State
Disabled
VCG Flow
Control
Provisione d Value
Don’t Care
Enabled
Transparent
Local
None
(Disabled)
Flow
Control
Status
Use/Comments
Disabled
Flow control is disabled for that port/link. Flow control requests are ignored and discarded.
End-to-End
Mode
Enabled
The LAN port responds to flow control requests by stopping frame transmission. Flow control requests are generated and sent to far end DMX based on congestion. Frames are dropped once the egress buffer is full.
LAN port generates flow control requests due to congestion from the far end DMX.
For Ethernet Private Line Full Rate Service
(Point-to-Point).
Local
Mode
Enabled
Disabled
The LAN port responds to flow control requests by stopping frame transmission. No flow control requests are sent to far end DMX.
LAN port generates flow control requests for fractional service.
For Ethernet Private Line Fractional (Partial)
Rate Service and Packet Ring Services.
The LAN port responds to flow control requests by stopping frame transmission. No flow control requests are sent to the far end DMX.
LAN port does not generate flow control requests.
A - 6 4
365-372-300
Issue 8.0 September 2006
Ethernet Transport
: Ethernet/SAN
LAN Port
Flow
Control
State
Flow Control Provisioning (LNW71 Circuit Pack)
The LNW71 circuit pack automatically provides both local and end-to-end flow control if flow control is enabled for a LAN port.
Similarly, disabling flow control for an LAN port disables both forms of flow control.
The following table shows the flow control settings for the LNW71 circuit pack.
Flow
Control
Status
Use/Comments
Disabled
Enabled
Disabled
Enabled
DMX does not participate in flow control.
The LAN port does not respond to flow control requests.
The LAN port does not generate flow control requests due to congestion.
Flow control requests are transported when received.
The LAN port responds to flow control requests by stopping frame transmission. Flow control requests are sent to the far end DMX. Frames are stored in the
Latency buffer for loss-less transmission.
LAN port generates flow control requests for fractional service.
365-372-300
Issue 8.0 September 2006
A - 6 5
Ethernet Transport
: Ethernet/SAN
Flow Control Provisioning (LNW70/74/63 Circuit Pack)
The LNW70/74/63 circuit pack automatically provides both local and end-to-end flow control if flow control is enabled for a LAN port.
Similarly, disabling flow control for an LAN port disables both forms of flow control.
The following table shows the flow control settings for the
LNW70/74/63 circuit pack.
LAN Port
Flow
Control
State
Flow
Control
Status
Use/Comments
Disabled
Enabled
Disabled
Enabled
DMX does not participate in flow control.
The LAN port does not respond to flow control requests.
The LAN port does not generate flow control requests due to congestion.
Flow control requests are transported when received.
Flow control requests are sent to the far-end DMX. LAN ports generate flow control requests for fractional service.
Disables Network-element controlled flow control and
Drop Drop drops end-to-end flow control messages.
A - 6 6
365-372-300
Issue 8.0 September 2006
Ethernet Transport
: Ethernet/SAN
Physical interface
Each Ethernet circuit pack contains a transceiver that implements the physical interface for that circuit pack's line type. For the 10/100 Mbps circuit packs, this physical interface must be provisioned to or auto-negotiate to the proper line rate and duplex mode in order to communicate successfully with the connected equipment. Gigabit
Ethernet interfaces only support the 1000 Mbps line rate and full duplex mode, so this is not an issue for these circuit packs. All optical
100BASE-LX interfaces support the 100 Mbps line rate only.
At the physical layer, many types of LANs can be used for multiple line rates and duplex modes. For example the LAN port on most PCs can be connected to a 10BASE-TX (10 Mbps) or a 100BASE-TX (100 Mbps)
LAN. Before data traffic can be transmitted onto a LAN, all ports connected to the LAN must operate with the same line rate and duplex mode. LAN ports can either be provisioned with these values or provisioned to automatically negotiate (auto-negotiate) the values.
Auto-negotiation
In the auto-negotiation process, a LAN port advertises its acceptable parameters, compares these with the advertised parameters of its link partner, and then agrees upon a set of parameters with the link partner.
IEEE 802.3 allows the line rate, duplex mode, and flow control mode to be auto-negotiated. A LAN port not configured to support auto-negotiation will use provisioned values for these parameters. A
LAN port configured for auto-negotiation that is connected to a LAN port not configured for auto-negotiation will follow prescribed rules for parameter settings.
On connected 1GSX/1GLX Ethernet ports with auto-negotiation enabled, if transmission is interrupted in one direction of transmission on a 1GSX/1GLX Ethernet port, then transmission is disabled in the other direction. For example, if one fiber in the transmit/receive pair is cut, then one-way transmission on the other fiber is maintained only if auto-negotiate is disabled and the link state is forced good at the transmit source equipment.
365-372-300
Issue 8.0 September 2006
A - 6 7
Ethernet Transport
: Ethernet/SAN
Line Rate Operation for LNW66, LNW71, and LNW74 Circuit Packs
The following table summarizes line rate operation for the LNW66,
LNW71, and LNW74 Ethernet circuit packs.
DMX LAN Port
10
Provisioning
100
Rate
Connected Equipment
Provisioning
Auto-Negotiation
Advertised/
Set at
Disabled
Disabled
Enabled
Enabled
Enabled
Disabled
Disabled
Enabled
Enabled
Enabled
Disabled
Disabled
10
100
10
100
10/100
10
100
10
100
10/100
10
100
Ethernet
Link Rate
(Note 1)
10
No Link
10
No Link
10
No Link
100
No Link
100
100
10
100
Auto Enabled
Enabled
10
100
10
100
Enabled 10/100 100
Note 1: Both the DMX and the connected equipment will try to determine a common line rate. The link will not come up if both ends have auto-negotiation enabled and advertise incompatible duplex modes.
A - 6 8
365-372-300
Issue 8.0 September 2006
Ethernet Transport
: Ethernet/SAN
Duplex Mode Operation for LNW66 Circuit Packs
The following table summarizes duplex mode operation for the
LNW66 Ethernet circuit packs.
DMX LAN Port
Provisioning
Connected Equipment
Provisioning
Duplex
Mode
Auto-
Negotiation
State
(Note 1)
Auto-
Negotiation
Advertised/
Set at
Auto Enabled
Disabled
Disabled
Enabled
Full
Half
Full
Half
Half
Full
Duplex Mode State
DMX
(Note 2)
Connected
Equipment
Bidirectional
Traffic (Link
Rate must be resolved)
Full
Half
Full
No
Yes
Yes
Full
Enabled
Enabled
Enabled
Disabled
Disabled
Enabled
Enabled
Enabled
Disabled
Half
Half/Full
Full
Half
Full
Half
Half/Full
Full
Half
Full
Half
Full
Unavailable Full
Unavailable Half
Full
Full
Full
Full
Full
Note 3
Full
Full
Yes
Yes
No
No
Yes
No
Yes
Yes
Half
Disabled
Enabled
Disabled
Enabled
Enabled
Enabled
Disabled
Disabled
Enabled
Enabled
Enabled
Half
Full
Half
Half/Full
Full
Half
Full
Half
Half/Full
Full Half
Unavailable Note 4
Full
Full
Half
Half
Half
Half
Full
Half
Unavailable Note 4
Half Half
Half Half
No
Yes
No
Yes
Yes
No
No Note 4
No
No
365-372-300
Issue 8.0 September 2006
A - 6 9
Ethernet Transport
: Ethernet/SAN
DMX LAN Port
Provisioning
Connected Equipment
Provisioning
Duplex
Mode
Auto-
Negotiation
State
(Note 1)
Auto-
Negotiation
Advertised/
Set at
Half Disabled
Disabled
Disabled
Enabled
Enabled
Full
Half
Full
Half
Duplex Mode State
DMX
(Note 2)
Half
Half
Half
Half
Connected
Equipment
Bidirectional
Traffic (Link
Rate must be resolved)
Full
Half
Note 4
Half
No
Yes
No (Note 4)
Yes
Enabled Half/Full Half Half Yes
Notes:
1. Auto-negotiation will be enabled if Line Rate or Duplex Mode or Flow Control is provisioned for auto-negotiation.
2. Duplex mode will be reported as unavailable if the link could not be established.
3. The link will not come up because the duplex mode could not be established.
4. According to IEEE 802.3, the connected equipment should default to half duplex. Because that equipment doesn’t support half duplex the link may be prevented from coming up. If it does come up, bidirectional traffic will not be supported.
A - 7 0
365-372-300
Issue 8.0 September 2006
Ethernet Transport
: Ethernet/SAN
Flow Control Operation for LNW66, LNW71, and LNW74 Circuit
Packs
The following table summarizes flow control operation for the
LNW66, LNW71, and LNW74 Ethernet circuit packs.
DMX LAN Port
Provisioning
Connected Equipment
Provisioning
Flow
Control
Auto-
Negotiation
State
(Note 1)
Auto-
Negotiation
Advertised/
Set at
(Note 2)
Duplex Mode State
DMX
(Note 3)
Connected
Equipment
Comments
(Note 4)
Auto Enabled
Disabled
Disabled
Enabled
Enabled
Enabled
Disabled
Enabled
Inconsistent
Provisioning
Inconsistent
Provisioning
Enabled
Disabled
Enabled
Note 5
Note 6
Disabled
Enabled
Enabled
Disabled
Disabled
Enabled
Enabled
Enabled
Disabled
Enabled
Inconsistent
Provisioning
Inconsistent
Provisioning
Enabled
Disabled
Enabled
Enabled
Enabled
Disabled
Enabled
Enabled
Disabled
Disabled Enabled Disabled
Inconsistent
Provisioning
Enabled Enabled Enabled
Disabled
Enabled
Disabled
Enabled
Enabled
Enabled
Unknown
Unknown
Inconsistent
Provisioning
Inconsistent
Provisioning
365-372-300
Issue 8.0 September 2006
A - 7 1
Ethernet Transport
: Ethernet/SAN
A - 7 2
DMX LAN Port
Provisioning
Connected Equipment
Provisioning
Flow
Control
Auto-
Negotiation
State
(Note 1)
Auto-
Negotiation
Advertised/
Set at
(Note 2)
Duplex Mode State
DMX
(Note 3)
Connected
Equipment
Comments
(Note 4)
Enabled
Disabled
Disabled
Enabled
Disabled
Disabled
Disabled
Enabled
Inconsistent
Provisioning
Inconsistent
Provisioning
Disabled
Enabled
Disabled
Enabled
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Enabled
Enabled
Disabled
Enabled
Disabled
Disabled
Disabled
Enabled
Unknown
Unknown
Inconsistent
Provisioning
Inconsistent
Provisioning
Inconsistent
Provisioning
Notes:
1. Auto-negotiation will be enabled on the LNW66 LAN port if Line Rate or Duplex Mode or Flow
Control is provisioned for auto-negotiation. Auto-negotiation will be enabled on the LNW71 LAN port if Line Rate or Flow Control is provisioned for auto-negotiation
2. Flow control will only be enabled if the connected equipment is capable of Symmetric Flow Control.
3. IEEE 802.3 does not define flow control states for half duplex links or when only one side of a link is provisioned for auto-negotiation. This is the expected behavior of the connected equipment.
4. IEEE 802.3 recommends that equipment be configured for auto-negotiation to avoid inconsistent provisioning.
5. On LNW66 LAN ports, flow control will be enabled if the duplex mode is provisioned for half duplex and disabled if the duplex mode is provisioned for full duplex or auto-negotiate. Flow control will be disabled on LNW71 LAN ports.
6. Flow control will be enabled on LNW71 LAN ports. On LNW66 LAN ports, flow control will be enabled if the duplex mode is provisioned for full duplex, or auto-negotiates to full duplex, or is provisioned for half duplex. It will be disabled on LNW66 LAN ports if the duplex mode auto-negotiates to half duplex.
Important!
Flow control on all optical Fast Ethernet ports must be provisioned manually.
365-372-300
Issue 8.0 September 2006
Ethernet Transport
: Ethernet/SAN
Flow Control Operation for LNW67, and LNW68, and LNW70
(100BASE-X ports only) Circuit Packs
The following table summarizes flow control operation for the
LNW67, and LNW68, and LNW70 (100BASE-X ports only) Ethernet circuit packs.
DMX LAN
Port Flow
Control
Provisioning
Connected Equipment
Provisioning
Auto-
Negotiation
Advertised/
Set at
(Note 2)
Flow Control State
DMX
(Note 2)
Connected
Equipment
Comments
(Note 3)
Auto
Disabled
Disabled
Enabled
Enabled
Enabled
Disabled
Enabled
Inconsistent
Provisioning
Inconsistent
Provisioning
Enabled
Disabled
Enabled
Disabled
Enabled
Disabled
Enabled
Disabled
Disabled Enabled Disabled
Inconsistent
Provisioning
Enabled Enabled Enabled
Enabled
Enabled
Disabled
Enabled
Enabled
Enabled
Unknown
Unknown
Inconsistent
Provisioning
Inconsistent
Provisioning
365-372-300
Issue 8.0 September 2006
A - 7 3
Ethernet Transport
: Ethernet/SAN
DMX LAN
Port Flow
Control
Provisioning
Connected Equipment
Provisioning
Auto-
Negotiation
Advertised/
Set at
(Note 2)
Disabled
Disabled
Enabled
Disabled
(Drop on
LNW70 only
4
)
Disabled
Enabled
Enabled
Flow Control State
DMX
(Note 2)
Disabled
Disabled
Disabled
Disabled
Connected
Equipment
Disabled
Enabled
Unknown
Unknown
Comments
(Note 3)
Inconsistent
Provisioning
Inconsistent
Provisioning
Inconsistent
Provisioning
Notes:
1. The link will not be operational if the connected equipment is not configured for 1 Gbps and full duplex mode.
2. Flow control will only be enabled if the connected equipment is capable of Symmetric Flow
Control.
3. IEEE 802.3 recommends that equipment be configured to avoid inconsistent provisioning.
4. Drop mode only applies for the LNW70 circuit pack.
Queues and buffers
Ethernet circuit packs contain small buffer pools that provide storage of
Ethernet frames for brief periods of congestion or until flow control requests can be honored. These small buffer pools are associated with the Ethernet switch and the Generic Framing Procedure (GFP) mechanism. The GFP mechanism is described further in “Generic framing procedure (GFP)” (A-31) . A larger buffer pool designed to handle different path lengths for individual STS-1s is associated with the virtual concatenation process. Its function is described in more detail in “Virtual concatenation” (A-33) . Two priority-based queues are provided on the LNW66/67/68 to allow high priority traffic to be forwarded ahead of low priority traffic. The LNW70 provides 4 priority queues. For more information refer to “Metering (CIR and
PIR)” (A-100) .
A - 7 4
365-372-300
Issue 8.0 September 2006
Ethernet Transport
: Ethernet/SAN
LNW66, LNW67, and LNW68 Circuit Pack Queues and Buffers
The Ethernet switches on LNW66, LNW67, and LNW68 circuit packs contain ingress (input) and egress (output) buffers. The following figure shows the LNW66, LNW67, and LNW68 circuit pack queue and buffer architecture.
Figure A-32 Queue and Buffer Architecture (LNW66, LNW67,
LNW68)
VCG
GFP Buffer
8K bytes
(5-128 Packets)
High
Priority
37
Packets
Low
Priority
Differential Delay Buffers 16ms
(94.5k bytes/STS-1)
GFP Buffer
8K bytes
(5-128 Packets)
40
Packets
2 or 4 VCG Ports
40
Packets
High
Priority
Low
Priority
37
Packets
Switch
Fabric
2 X 1GE LAN Port
(LNW67/68)
128
Packets
31 Packets
High
Priority
Low
Priority
3 X 8 LAN Ports
(LNW66)
MA-DMX-362
365-372-300
Issue 8.0 September 2006
A - 7 5
Ethernet Transport
: Ethernet/SAN
High and low priority queues are provided for packets leaving the
Ethernet switch in the direction of either the SONET network or a customer port. Each LAN and VCG port has one ingress and two egress queues. Ingress queues buffer Ethernet frames going into the Ethernet switch and egress queues buffer Ethernet frames leaving the Ethernet switch. One egress queue is for high priority Ethernet frames and the other egress queue is for low priority Ethernet frames.
On the LNW66 circuit pack, the LAN ports are divided into groups of eight. The groups consist of LAN ports 1-8, 9-16, and 17-24. Each group of eight LAN ports shares a set of 128 frame buffers. In the egress direction, each LAN port can buffer up to 31 Ethernet frames which can be placed in a high or low priority queue. Each LNW66 circuit pack VCG port can buffer 40 Ethernet frames in the ingress queue and a total of 37 Ethernet frames across the high and low priority egress queues.
All ports on the LNW67 and LNW68 circuit packs are independent and each port can buffer 40 Ethernet frames in its ingress queue and a total of 37 frames across its high and low priority egress queues.
All frame buffers are sized to handle the maximum frame size (1536 bytes). The buffer pool sizes described above are independent of frame size (that is, they do not increase if the Ethernet traffic consists of small frames).
A - 7 6
365-372-300
Issue 8.0 September 2006
Ethernet Transport
: Ethernet/SAN
LNW63/70/71/74 Circuit Pack Buffers
In Private Line Mode, the Ethernet frame buffers are all associated with the Generic Framing Procedure (GFP) and virtual concatenation mechanisms. The following figure shows the LNW63/70/71/74 circuit pack buffer architecture.
NOTE: In switched mode, the LNW70 buffers are provisionable up to
256 K.
Figure A-33 Buffer Architecture (LNW63/70/71/74)
VCG
GFP Buffer
LNW70 GbE--> up to 128K bytes
LNW70 FE--> up to 64K bytes
LNW71--> up to 64K bytes
LNW74--> up to 64K bytes
LNW63 GbE--> up to 128K bytes
Differential Delay BufFers
GFP Buffer
LNW70 GbE--> up to 2 Mb
LNW70 FE--> up to 200K bytes
LNW71--> up to 200K bytes
LNW74--> up to 200K bytes
LNW63 GbE--> up to 10 Mb
VCG Ports
LAN Ports
MA-DMX-363
The LNW63/70/71/74 circuit pack provides larger buffer pools to allow for longer response times to flow control requests. In addition, buffer storage can be flexibly assigned to Ethernet frames, allowing maximal usage of the memory available.
NOTE: For additional information on differential delay buffers, refer to “Differential Delay Buffers” (A-34) .
365-372-300
Issue 8.0 September 2006
A - 7 7
Ethernet Transport
: Ethernet/SAN
Head-of-Line (HOL) Blocking Prevention
As an Ethernet frame arrives from the SONET network destined for a customer LAN port on LNW66/67/68 circuit packs, it is placed in the egress queue associated with the destination LAN port(s). If that queue is full, the VCG port on which the packet arrived could hold the packet until space is available, but that would stop the incoming flow of all packets arriving on that VCG port, even those destined for uncongested
LAN ports. This situation is known as Head-of-Line (HOL) blocking.
To avoid Head-of-Line (HOL) blocking, the LNW66/67/68 circuit packs support the discarding of packets received on a VCG port destined for a LAN port with a full egress queue. Broadcast frames, multicast frames, and frames with unknown destination addresses are not discarded but are forwarded only to those LAN ports that are accepting traffic. Frames dropped due to HOL blocking prevention are not reported as dropped in the performance monitoring statistics.
HOL blocking prevention is used in the 802.1Q and transparent modes.
These modes are described in
A - 7 8
365-372-300
Issue 8.0 September 2006
: Ethernet/SAN
Tagging Modes
............................................................................................................................................................................................................................................................
Overview
Private line mode
DMX supports the following tagging modes.
• Private line mode (also know as no tag or repeater mode)
• Switched mode
• 802.1Q mode
• Transparent mode.
The tagging mode is user provisionable on a circuit pack basis.
Different circuit packs on a single DMX shelf can be provisioned for different modes but, all ports on a circuit pack must use the same mode.
The private line mode (also known as no tag or repeater mode) is used to establish simple point-to-point connections between two ports with no Ethernet switching functions applied. No additional Ethernet provisioning is required after the cross-connection is established.
Private line mode can be used to provide either a full rate or sub-rate
(fractional rate) dedicated Ethernet link across SONET networks. No preferential treatment for high priority packets is provided. In a sub-rate service, frames may be dropped due to congestion. Any correctly formatted Ethernet frame received at a source port is transmitted out of the destination port.
The private line mode supports the following features:
• Point-to-point topology with only two LAN ports
• MAC address filtering is enabled (not available for LNW71/74)
• Protection is provided at the SONET network layer by either
UPSR switching
• No spanning tree protocol (supports transparency of customer spanning tree protocol)
• No VLAN ingress filtering or classification (VLAN tags are not verified or added)
• Ethernet PM per port
For packet size info refer to
Packet size in different tagging modes
on
365-372-300
Issue 8.0 September 2006
A - 7 9
Tagging Modes
: Ethernet/SAN
Switched Mode
Switched mode allows 802.1Q or Transparent mode to be selected based on a virtual switch (grouping of ports). Refer to the sections below and to "Virtual switch" on page A-112 and
(LNW70 and LNW78)” (A-90) for more information.
802.1Q VLAN mode
In 802.1Q Mode, a circuit pack can be provisioned to use an incoming frame's VLAN tag, to add a VLAN tag associated with the port for untagged frames, or to drop an incoming frame if its VLAN tagging does not meet provisioned specifications. The priority bits in an incoming frame's VLAN tag can also be used to affect the handling of the frame.
The following table summarizes the 802.1Q Mode VLAN ID and
Frame Priority Rules. For more information regarding frame priority
rules on the LNW70 and LNW78, refer to “QoS services (LNW70 and
.
Frame
Contains a VLAN
Tag
Yes
No
Ingress Port is
Provisioned with a
Default
VLAN ID Priority
Don’t Care
Yes
No
Results
Yes
No
The frame’s VLAN ID is used. It must be on the Port’s VLAN List, otherwise the frame will be discarded.
The port’s user_priority field is used for queuing
.
The frame’s VLAN ID is used. It must be on the Port’s VLAN List, otherwise the frame will be discarded.
The frame’s priority is used for queuing.
Yes
No
A VLAN tag is added to the frame containing the port’s default VLAN ID and priority.
A VLAN tag is added to the frame containing the port’s default VLAN ID and the priority is set to low (VLAN
Tag’s User_priority field set to 0).
Don’t Care Frame is dropped.
A - 8 0
365-372-300
Issue 8.0 September 2006
Tagging Modes
: Ethernet/SAN
A VLAN ID can only be assigned to one virtual switch on a circuit pack.
On the LNW70/78, the same VLAN ID can be assigned to different virtual switches on the same pack.
When using the 802.1Q mode, a service provider must coordinate
(specify) the use of VLAN IDs with customers. If a VLAN ID is assigned to more than one customer, the customers could receive each others traffic.
In DMX, the VLAN ID may be a numerical value in the range 1-4093.
If a port has been provisioned with a default VLAN ID for untagged frames, all incoming untagged frames (this includes frames containing a VLAN tag with a TPID value other than 8100hex) will have VLAN tag added with the default VLAN ID. Any frame exiting the DMX network tagged with the default VLAN ID will have its VLAN tag removed before the frame is sent out the LAN port. Thus, assuming symmetric provisioning at the network edges, frames that enter the
DMX network untagged will leave untagged as well.
Frames that enter the network carrying a standard 802.1Q VLAN tag
(identified with a TPID value of 8100hex) have their VLAN ID checked against a VLAN list for the entry port. If a match is found, the frame is admitted; otherwise, the frame is discarded. On exiting the network, customer-tagged frames will be delivered with the customer-provided VLAN tag intact unless it matches the default
VLAN ID for the exiting port. In such a case, the customer-provided
VLAN tag will be removed before the frame is delivered.
365-372-300
Issue 8.0 September 2006
A - 8 1
Tagging Modes
A - 8 2
: Ethernet/SAN
Ethernet
The following figure shows the end-to-end frame processing combinations considering the following:
• Incoming frame tagging
• Default VLAN ID provisioning for source LAN port
• Default VLAN ID provisioning for destination LAN port
Figure A-34 802.1Q Mode VLAN Tag Processing
Ethernet
Over
SONET
Ethernet
Metropolis
DMX
®
Metropolis
®
DMX
Dropped if no default
VLAN ID provisioned
Packet
TPID=xxxx
(not 8100)
Tagged Packet
TPID=8100
Untagged
Packet
Dropped if no default
VLAN ID provisioned
Default
VLAN
Tagged
Packet
TPID=8100, xxxx
VLAN
List
Tagged Packet
TPID=8100 xxxx
Default
LAN
Packet
TPID=xxxx
VLAN
List
Default
VLAN
Tagged
Packet
TPID=8100
VLAN
List
Tagged Packet
TPID=8100
Default
VLAN
Untagged
Packet
LAN Port VLAN
Provisioning
MA-DMX-364
If VLAN tags are used, the ports support a maximum packet size of
1536 bytes (10236 for LNW70/78). If VLAN tags are not used, the ports support a maximum packet size of 1532 bytes (10240 for
LNW70/78).
The LNW66, LNW67, LNW68, LNW70, and LNW78 circuit packs support the 802.1Q mode. The LNW71 circuit pack does not support the 802.1Q mode.
Important!
After the VLAN ID is provisioned for untagged incoming Ethernet frames and service is established in the 802.1Q mode, changing the VLAN ID may affect service. When the
VLAN ID for untagged incoming Ethernet frames is changed at one point in the network, the VLAN ID must be changed at all points. If the VLAN IDs are different, service will be affected.
365-372-300
Issue 8.0 September 2006
Tagging Modes
: Ethernet/SAN
Transparent mode
In Transparent Mode, port tags (which are actually VLAN tags with a provisionable TPID value) are used to separate traffic for different customers. A port tag is added to each incoming frame at the ingress
LAN port. The port tag contains a provisionable customer ID and priority level.
The port tag, along with the destination MAC address, is used in switching the Ethernet frame to its correct destination. Assuming the destination port is also provisioned for Transparent Mode, the port tag is removed as the frame is delivered out the destination port.
When using the Transparent Mode, service providers usually assign one customer ID to each customer LAN port. The service provider need not coordinate the selection of this customer ID with the customer since it is independent of any 802.1Q VLAN tags generated by the customer.
Customers can use any VLAN ID they want without interfering with any other customer carried on the service provider's network.
In the transparent mode, the ports support a maximum packet size of
1532 bytes (LNW66/67/68) or 10240 bytes (LNW70/78).
The LNW66, LNW67, LNW68, LNW70, and LNW78 circuit packs support the transparent mode. The LNW71 and LNW74 circuit packs do not support the transparent mode.
365-372-300
Issue 8.0 September 2006
A - 8 3
Tagging Modes
: Ethernet/SAN
Ethernet
Tagged Packet
TPID=8100 or
TPID=8100, 8100 or
TPID=9100, 8100
Dropped if no default
TAG provisioned
Untagged
Packet
Dropped if no default
TAGID provisioned
The following figure shows end-to-end frame processing combinations considering the following:
• Provisionable TPID value set to its default value (0xFFFF)
• Incoming frame tagging
• Default port tag provisioning for the source LAN port
• Port tag provisioning for the destination LAN port.
Figure A-35 Transparent Mode Tag Processing
Default
TAG
Default
TAG
Metropolis
®
DMX
Ethernet
Over
SONET
Tagged Packet
TPID=FFFF, 8100 or
TPID=FFFF, 8100, 8100 or
TPID=FFFF, 9100, 8100
Tagged
Packet
TPID=FFFF
Metropolis
®
DMX
TAG
List
Default
TAG
TAG
List
Ethernet
Tagged Packet
TPID=FFFF, 8100 or
TPID=FFFF, 8100
8100 or
TPID=FFFF, 9100,
8100
Tagged Packet
TPID=8100 or
TPID=8100, 8100 or
TPID=9100, 8100
Tagged Packet
TPID=FFFF
Default
TAG
Untagged
Packet
LAN Port TAG
Provisioning
Provisionable
TPID=FFFF
MA-DMX-365
A - 8 4
365-372-300
Issue 8.0 September 2006
Tagging Modes
: Ethernet/SAN
365-372-300
Issue 8.0 September 2006
TPID Provisioning and Tag List Provisioning
In Release 4.0 and later releases, the value of the TPID (Ethertype) parameter used with generated VLAN Tags can be provisioned (in transparent mode only). Also starting in Release 4.0, the user may provision a list of acceptable customer tags for a LAN port. This pair of added features allows DMX to interoperate with other equipment that supports stacked VLANs.
The TPID became provisionable on DMX in Release 4.0. In Releases prior to Release 4.0, the TPID parameter is not provisionable and has a proprietary value of FFFFhex.
The following figure shows the end-to-end frame processing combinations considering the following:
• User provisionable TPID value (to 0x9100 in the example)
• Incoming frame tagging
• Default port tag provisioning for the source LAN port
• Port tag provisioning for the destination LAN port.
Figure A-36 Transparent Mode Tag Processing with Stacked
VLANs
Ethernet
Metropolis
®
DMX
Ethernet
Over
SONET
Metropolis
®
DMX
Tagged Packet
TPID=9100 or
TPID=8100, 8100 or
TPID=9100, 8100
Dropped if
TAG associated with
TPID=9100 not in Tag List
TAG
List
Tagged Packet
TPID=9100 or
TPID=9100, 8100
Untagged
Packet
Dropped if no default
TAG provisioned
Default
TAG
Tagged
Packet
TPID=9100
LAN Port TAG
Provisioning
®
DMX = Metropolis DMX Access Multiplexer
Provisionable
TPID=9100
TAG
List
Default
TAG
TAG
List
Default
TAG
Ethernet
Tagged Packet
TPID=9100 or
TPID=9100, 8100
Packed
Untagged or
TPID=8100
Tagged Packet
TPID=9100
Untagged
Packet
MA-DMX-366
A - 8 5
Tagging Modes
: Ethernet/SAN
Packet size in different tagging modes
The following table shows a comparison of the Ethernet tagging modes.
Tagging
Mode
Private Line
802.1Q
Transparent
VLAN Tag
N/A
Coordinated with customers
Independent of customer tags
VLAN
Filtering
No
Yes
No
Spanning
Tree
Priority
No
Optional
Optional
No
VLAN or Port
Based
Port
Based
Max.
Frame Size
(Bytes)
1532
Applicable
Circuit
Packs
LNW67,
LNW68
MTU
Size
NA
NA
9614
10240 LNW71
9632 LNW74
10240
LNW70,
LNW63
1536
(Tagged)
1532
(Untagged)
LNW66,
LNW67,
LNW68
10222
NA
10240
LNW70,
LNW78
10222
1536
(Tagged)
1532
(Untagged)
LNW66,
LNW67,
LNW68
NA
10240
LNW70,
LNW78
10222
A - 8 6
365-372-300
Issue 8.0 September 2006
: Ethernet/SAN
Quality of Service
............................................................................................................................................................................................................................................................
Overview
DMX supports the following Quality of Service (QoS) capabilities:
• Private line service provides dedicated bandwidth between two points service (best QoS).
• Fractional rate services provide basic rate shaping with SONET tributary granularity.
• Committed information rate (CIR) policing provides rate limiting with 1 Mbps granularity.
• Peak information rate (PIR) policing provides rate limiting with 1
Mbps granularity.
• LNW70 enables advanced QoS capabilities including CIR rate metering.
For detailed information about Ethernet frame priority levels, refer to “Priorities” (A-47) and “802.1Q VLAN mode” (A-80) .
Peak information rate (PIR) shaping on LNW66,
LNW67, and LNW68 circuit packs
The LNW66, LNW67, and LNW68 circuit packs support a provisionable PIR rate limiting mechanism for traffic entering the
SONET network. A PIR value, in multiples of 1 Mbps, can be provisioned per VLAN for traffic leaving a VCG toward the SONET network. Traffic in excess of the provisioned value for each VLAN will be dropped. The PIR capability applies to all tagging modes supported by the listed circuit packs. For the LNW67 and LNW68 circuit packs in private line mode, PIR is specified per port rather than per VLAN.
The PIR policer uses a leaky bucket mechanism with a provisionable burst size and credit interval. The burst size determines how many tokens get put into the bucket each time it is replenished. This determines the length of a traffic burst that can be tolerated before packets are discarded. The credit interval determines the frequency with which the bucket is replenished. The burst size and credit interval parameters affect policing for all ports (in private line mode), all
VLANs (in 802.1Q mode) or all port tags (in transparent mode) on a particular Ethernet circuit pack.
Note that when sending data from a Gigabit Ethernet circuit pack, through the SONET network to a Fast Ethernet circuit card, the function described above is slightly different. With this configuration, the worst case is that a number of bytes equal to the full size of the token bucket in the GbE circuit pack will be sent using whatever SONET bandwidth has been provisioned (approximately 1 Gb/s in the worst case) to the
365-372-300
Issue 8.0 September 2006
A - 8 7
Quality of Service
A - 8 8
: Ethernet/SAN
Fast Ethernet card. The egress FE LAN port will be limited to sending the data out at 100 Mb/s. If the rapid arrival of a token bucket's worth of bytes exceeds the limited egress buffering capacity of the FE LAN port, packets will be dropped. This loss of packets can be minimized by minimizing the number of bytes in the token bucket at the GbE sending end by setting the smallest practical credit interval and burst size.
For more detailed information on metering, refer to “Metering (CIR and PIR)” (A-100) .
Adding Tokens
Every credit interval, tokens are added to the token bucket for each
VLAN/Port TAG/LAN port for which a PIR is provisioned. Each token represents 1 byte. (One credit interval is provisioned per circuit pack, and the provisioned credit interval applies to all VLANs/Port
TAGs/LAN ports on that circuit pack. The credit interval is a multiple of 524.288 µs; the multiple is determined by the provisionable credit interval parameter.)
The number of available tokens (A) in the token bucket for each
VLAN/Port TAG/LAN port is increased by at most,
(PIR*credit interval)/8 each credit interval, where PIR is the provisioned PIR in Mbps, and
credit interval is the provisioned credit interval for the circuit pack.
The divisor, 8, is required to convert from bits to bytes.
The number of available tokens (A) in each token bucket is subject to a maximum, which is determined by the provisioned PIR, the provisioned credit interval, and the provisioned maximum burst parameter. So each credit interval,
A = min (A + (PIR*credit interval)/8, BRST*(PIR*credit interval)/8)
The maximum burst represents the maximum size (in bytes) of the
burst (above the PIR) that will be passed by the policer. That is, a burst of this size (or smaller) will be allowed through the policer if the token bucket for the VLAN/Port TAG/LAN port is full (for example, because no packets have been processed for BRST credit intervals). If a burst of this size is passed, then the token bucket will be emptied and another burst will not be allowed through the policer until enough tokens have been accumulated in the token bucket. Another way to look at this is that the policer will pass a burst of packets above the PIR, as long as the long term average is no more than the provisioned PIR, where long term is defined as BRST*credit_interval.
365-372-300
Issue 8.0 September 2006
Quality of Service
: Ethernet/SAN
Removing Tokens
When a packet arrives, the token bucket for the associated VLAN/Port
TAG/LAN port is checked.
If no tokens are available for the VLAN/Port TAG/LAN port, then the packet is discarded.
If tokens are available, the packet is forwarded and the number of available tokens for that VLAN/Port TAG/LAN port is decreased by the packet size:
If A >= 1 A = A - packet size and forward the packet, else discard the packet.
QoS services (LNW71/74)
The LNW71 and LNW74 circuit packs provide 10 Mbps and 100 Mbps private line services. They do not contain an Ethernet Switch. Each
LAN port is connected to its own VCG. 100 Mbps traffic can be rate-limited by provisioning less SONET bandwidth than required to carry the full line rate. Traffic is buffered and flow control is invoked when ingress traffic on a LAN port exceeds the VCG’s SONET bandwidth. If flow control is disabled or ignored by the external equipment, Ethernet frames are dropped when the ingress buffer overflows. The LNW74 offers 1.5Mbps VT granularity.
365-372-300
Issue 8.0 September 2006
A - 8 9
Quality of Service
: Ethernet/SAN
QoS services (LNW70 and
LNW78)
The capabilities of the LNW70, available beginning in R5.1, enable enhanced QoS features. The LNW70 can function in either Private Line or Switched mode. The LNW78 is available beginning in R6.0. It is an
RPR enabled switched Ethernet card. It does not support Private Line.
The QoS capabilities of the LNW70 are different depending on the mode the card is in. Also, within the two modes below, there are a variety of traffic conditioners which can be applied, depending on the mode) which further govern the QoS capabilities of the pack.
• Private Line: DMX can perform rate controlling at a sub-STS level and on a per-port basis in PL mode. In PL mode, if rate control is desired, the traffic management mode will be port mode
(see Traffic Conditioners below). LNW78 does not support private line.
• Switched Mode: DMX can perform VLAN processing and enhanced QoS in switched mode. There are two settings within switched mode: Transparent and IEEE 802.1q mode. Refer to
In order to provide enhanced QoS services, traffic must be classified, and conditioned. This is accomplished using traffic conditioners that are applied to packets at the boundary port (see Boundary vs. Interior
Port below).
A - 9 0
365-372-300
Issue 8.0 September 2006
Quality of Service
365-372-300
Issue 8.0 September 2006
: Ethernet/SAN
Traffic Management Mode
The QoS features available on any given port will vary depending on the particular traffic conditioners applied to that port. The 5 traffic conditioners supported by DMX are as follows:
• PORT mode: One traffic conditioner for the port. All traffic that is permitted to be transported flows through a single traffic conditioner.
• COSPORT mode: One traffic conditioner for each class of service at the port. All traffic for an individual CoS is provisioned with its own traffic conditioner.
• TAGPORT mode: One traffic conditioner for each Packet Tag at the port. Traffic for all classes of service that have the same Packet
Tag flow through a single traffic conditioner.
• COSTAGPORT mode: One traffic conditioner for each class of service for each Packet Tag/VLAN at the port. All traffic for an individual CoS on each Packet Tag is provisioned with its own traffic conditioner.
• NOTC mode: In this mode all traffic is bridged through the switch as usual but there is no traffic conditioning performed on the traffic. NOTC mode emulates the (basic) QoS behavior on the older DMX circuit packs (user_priority values 0,1,2 and 3 are mapped to CoS 0 and user_priority values 4,5,6 and 7 are mapped to CoS 3; no modification of user_priority bits in user packets).
Boundary versus Interior Ports
When speaking of QoS, a port is either a Boundary or Interior port. A boundary port is at the edge of a differentiated services (DiffServ) domain and an Interior port in a the core of a DiffServ domain. All traffic policing, conditioning, and marking is done at boundary ports. It is assumed that these functions have been performed by the time packets reach the interior ports. Boundary/Interior demarcation is controlled by an explicit parameter. By way of provisioning, a LAN port can be either boundary or interior, but a VCG is usually an interior port. A VCG can be a boundary port, but this limits the traffic management mode provisionable for that port to NOTC only.
QoS functionality is built around the concept of boundary and interior ports. Though the terminology customer and network are often used in place of boundary and interior (where customer equals boundary and interior equals network), this is incorrect with reference to DMX.
However, customer and network terminology is still applied to ports
A - 9 1
Quality of Service
: Ethernet/SAN
with respect to their overall VLAN tagging behavior, rather than QoS specific functions.
For the LNW78 RPR card the following is true. An RPR VCG is always interior. A LAN port is always boundary.
The table below details what traffic management modes are allowed to be provisioned on ports depending on wether they are boundary or interior ports. Attempts to provision a VLAN tagging mode/traffic management mode combination that is not listed in the table below shall be denied.
Table A-2 Allowed Traffic Management Modes per Port Type
Traffic Management Mode
VLAN Tagging Mode Port Type
Private Line
Transparent
802.1TAG
Boundary Port*
Interior Port*
Boundary Port
Interior Port
Boundary Port
LNW70
NOTC
PORT
N/A
COSPORT
NOTC
PORT
N/A
NOTC
PORT
TAGPORT
COSPORT
COSTAGPORT
N/A
N/A
LNW78
PORT
N/A
N/A
PORT
N/A
COSPORT
N/A
Interior Port N/A N/A
*NOTE: In Private Line mode, it is not possible to change the Boundary/Interior demarcation of LAN and
VCG ports. The LNW78 does not support Private Line
A VCG can be a boundary port, but this limits the traffic management mode provisionable for that port to NOTC only.
A - 9 2
365-372-300
Issue 8.0 September 2006
Quality of Service
: Ethernet/SAN
Untagged or Unprovisioned Packets
The table below explains what happens at the ingress when untagged or unconditioned packets are received. If a packet arrives at a port and it is marked with a CoS and Packet Tag for which a traffic conditioner has not been provisioned at that particular port, the traffic will be handled as described in the table below.
Table A-3 Handling of Untagged or Unprovisioned service at
Boundary Ports
VLAN tagging mode
Private Line
Private Line
Transparent
Transparent
802.1TAG
Traffic Management mode
NOTC
PORT
NOTC
PORT
NOTC
Untagged traffic
Pass all traffic unmodified
Pass all traffic unmodified
Tag with default port tag and default CoS and pass traffic
CoS-Packet Tag
Traffic Conditioner not provisioned
Pass all traffic unmodified
Pass all traffic unmodified
Not Applicable
Tag with default port tag and default CoS and pass traffic
Tag with default port tag and default CoS and pass traffic unmetered
(marked Yellow)
Tag with default
VLANid and default
CoS and pass traffic
Not Applicable
365-372-300
Issue 8.0 September 2006
A - 9 3
Quality of Service
A - 9 4
: Ethernet/SAN
QoS in Private Line Mode
Private Line mode should be employed when deploying point-to-point service connections using dedicated resources. Private Line can either be a full-rate service or a subrate service. Full-rate services dedicate enough network resources to transport the data from the ingress
Boundary Port through the network to the egress Boundary Port at the full data rate of the Boundary Ports. Subrate services transport data at a fraction of the full data rate of the Boundary Ports.
In Private Line Mode, the Boundary Ports (see Boundary vs. Interior
Ports above) can have either NOTC or PORT traffic management mode; the Interior Ports are always NOTC. All packets received are handled uniformly using a single queue. Packets are not modified or remarked in this mode. Therefore, it is not possible to encode color.
Consequently, packets are either dropped or passed-through transparently. This is achieved by setting CIR values equal to PIR values and by forcing CBS to equal PBS.
QoS in Transparent and 802.1q mode
Transparent mode
Transparent mode provides a trunked Private Line or “Virtual Private
LAN” service. The Boundary Ports use either a NOTC or PORT traffic management mode. In transparent mode, customers packets are not changed.
In NOTC mode, just as with Private Line, there is no traffic conditioning performed on any of the boundary Ports. Traffic conditioning is never performed on the Interior ports.
In the PORT mode all traffic that enters the port is tagged (stacked
VLAN) with the provisioned TPID and the default port tag. The CoS is set to the default priority for that port and the user_priority is set based on this CoS and the conformance level determined in the traffic conditioner.
Packets that are within the committed contract parameters are marked with a Drop Precedence of DP1 (green). Packets that arrive out of the guaranteed contract, but within some allowable excess, are marked with a Drop Precedence of DP0 (yellow). Packets that arrive outside of the allowed excess are discarded.
The user_priority is determined from the CoS level and Drop
Precedence. The packet is remarked with this user_priority before leaving the egress port.
365-372-300
Issue 8.0 September 2006
Quality of Service
365-372-300
Issue 8.0 September 2006
: Ethernet/SAN
In both NOTC and PORT mode, if no default priority is specified for the port, the CoS value is set to 0. There is no traffic conditioning on
Interior Ports (see Boundary vs. Interior Ports above).
With Transparent tagging, both PIR, CIR, PBS and CBS are used to allocate the appropriate network resources to each service. Transparent mode supports user network configurations with more than two nodes in case a multipoint “Virtual Private LAN” service is needed. For this service each Boundary Port is provisioned with the same default port tag and default priority. This results in the required traffic separation to provide a virtual private network.
802.1q mode
The 802.1TAG tagging mode assumes that packets arrive at the boundary to the network already tagged with a standards-compliant
VLAN tag. It is possible then to offer a number of services at a single port simultaneously.
In 802.1q mode, the packets should be tagged by the subscriber, however, some packets may arrive untagged. The CoS level for tagged packets is determined either by the default port CoS level (PORT mode) or the default VLAN CoS level (TAGPORT mode), or by examining the user_priority and setting the CoS according to a fixed mapping (NOTC and PORT mode), or according to a provisionable mapping table. The mapping table is associated either with a port
(COSPORT mode) or a VLAN (COSTAGPORT mode). Untagged traffic is tagged with the default VLAN. The CoS is then set to either the default port CoS level (NOTC,PORT,COSPORT mode) or the default VLAN CoS level (TAGPORT, COSTAGPORT mode). The packets are then conditioned (except for NOTC) in the same fashion as tagged traffic.
Priority-tagged traffic is tagged with the default VLAN, and the CoS level is determined as it would be for a tagged packet.
In all cases, the Drop Precedence (DP) is set according to the level of conformance specified in the customer's SLA contract.
The functionality of each traffic management with regard to 802.1q mode is detailed below:
• PORT:
The PORT mode of operation, is very similar to the services offered in the Transparent tagging mode, except that in this case the standard TPID (Ethertype) of 8100 is used so that this mode is interoperable with other 802.3 networks. Also more than one VLANid
A - 9 5
Quality of Service
A - 9 6
: Ethernet/SAN
can be supported at a single port and treated as a single traffic flow. In this mode the traffic conditioning for all traffic that is admitted to the port is performed as an aggregate data flow by a single traffic conditioner. Only traffic that is either untagged or tagged with a
VLANid that has been provisioned at the port will be admitted. In this mode the user_priority bits will be remarked according to the packets
user_priority (0,1,2,3 map to CoS 0 and 4,5,6,7 map to CoS 3) unless overruled by the default priority. Drop Precedence is determined as a result of the packets conformance to the SLA. Any remarking that occurs is irreversible and will be present on the packet at the network egress.
•
TAGPORT:
In the TAGPORT mode of operation, a single CoS is associated with each VLAN. The traffic flows through a traffic conditioner per VLAN where it is metered and policed as per the terms of the SLA. In this mode each VLAN has its own PIR, CIR, PBS and
CBS. Packets that arrive untagged are tagged with the port default
VLANid and CoS for that VLAN. As with the other modes, the Drop
Precedence is determined based on the conformance to the SLA. Any remarking that occurs is irreversible and will be present on the packet at the network egress.
•
COSTAGPORT:
In the COSTAGPORT mode of operation, traffic for each CoS on each VLAN flows through its own traffic conditioner.
Traffic that is tagged with one of the port’s provisioned VLANids is admitted to the network. Packets that arrive untagged or priority-tagged are tagged with the port default VLANid. Packets tagged with an unprovisioned VLANid are discarded. The user_priority bits in a priority-tagged frame are used to determine the CoS when selecting the traffic conditioner. In this mode each CoS on each VLAN has its own
PIR, CIR, PBS and CBS. On each VLAN each CoS can be individually enabled or disabled. The Drop Precedence is determined by the SLA conformance level and the packet is remarked accordingly. This marking is not reversible and will be present when the packet egresses the network.
• COSPORT:
In the COSPORT mode of operation, traffic for each class of service flows through its own traffic conditioner. Traffic that is tagged with one of the port’s provisioned VLANids is admitted to the network.
Packets that arrive untagged or priority-tagged are tagged with the port default VLANid. Packets tagged with an unprovisioned VLANid are discarded. The user_priority bits in a priority-tagged frame are used to determine the CoS when selecting the traffic conditioner. In this mode each CoS has its own PIR, CIR, PBS and CBS. Each CoS can be
365-372-300
Issue 8.0 September 2006
Quality of Service
365-372-300
Issue 8.0 September 2006
: Ethernet/SAN
individually enabled or disabled. The Drop Precedence will be remarked according to the conformance to the SLA. This marking is not reversible and will be present when the packet egresses the network.
The table below shows the default mapping of user priority bits to CoS.
Table A-4 Default mapping of User Priority to CoS user_priority
000
001
010
011
100
101
110
111
2
2
0
1
CoS
1
0
3
3
The table below shows the default mapping of DSCP to CoS. In R6.0,
DMX adds support of DSCP for traffic classification on the LNW70.
DSCP to CoS is available in PORT mode only. DSCP can be used as an alternative to priority bits. So, the criteria for traffic classification can now be user priority bits, DSCP, VLANid, or default value. DSCP allows for three differentiated services code point values: IP precedence value (also called Class Selector-- CS in the table below),
Assured Forwarding (AF), and Expedited Forwarding (EF).
Table A-4 Default mapping of DSCP to CoS
CoS
0
2
2
0
2
1
1
DSCP
Default
CS1
AF11
AF12
AF13
CS2
AF21
Binary
000000
001000
010010
001100
001110
010000
010010
Decimal
0
8
10
12
14
16
18
A - 9 7
Quality of Service
3
3
0
2
3
0
0
0
2
CoS
1
0
0
1
1
: Ethernet/SAN
AF33
CS4
AF41
AF42
AF43
CS5
EF
CS6
CS7
DSCP
AF22
AF23
CS3
AF31
AF32
011110
100000
100010
100100
100110
101000
101110
110000
111000
Binary
010100
010110
011000
011010
011100
38
40
46
48
56
30
32
34
36
Decimal
20
22
24
26
28
A - 9 8
365-372-300
Issue 8.0 September 2006
Quality of Service
: Ethernet/SAN
The table below shows the characteristics of which services are offered relative to the VLAN tagging mode and traffic management mode.
These characteristics include the number of services allowed at a port as well as the number allowed on the network. Certain columns are divided into LNW70 and LNW78, this is only done where the LNW78 supports the management mode detailed in that column.
Table A-5 Combination of VLAN Tagging and Traffic
Management Modes
Transparent
Private Line 802.1TAG
No.
Services at 1 port
1
1
No.
Services on
Network
2
NOTC PORT NOTC
PORT
LNW78
1
1
1
1
1
1
1 to
4093
Max. CoS
Support
3
Traffic
Conditioning
4
No No No
1
CoS/
Port
PIR
None
PBS
CIR
CBS
Non e
PIR
PBS
CIR
CBS
COSPORT
NOTC
LNW70
1 1
COSPORT
PORT
TAGPORT
COSTAG
PORT
1
LNW78 LNW70
1
LNW78 LNW70
1 per
VLANi d
4093 max.
1 per
CoS
Level
1 per
CoS
Level
3 max.
4 max.
1 per
CoS
Level per
VLANi d
16,372 max.
1 to
4093
1
1 to
4093
1 to
4093
1 to
4093
1 to
12,279
1 to
16,372
1 to
16,372
1 CoS/
Port
PIR
PBS
CIR
CBS
No
None
3 CoS/
Port
4 CoS/
Port
4 CoS/
VLAN
PIR
PBS
CIR
CBS
PIR
PBS
CIR
CBS
PIR
PBS
CIR
CBS
3 CoS/
Port
4
CoS/P ort
4 CoS/
VLAN
PIR
PBS
CIR
CBS
PIR
PBS
CIR
CBS
PIR
PBS
CIR
CBS
365-372-300
Issue 8.0 September 2006
A - 9 9
Quality of Service
: Ethernet/SAN
Transparent
Private Line 802.1TAG
COSPORT
NOTC
COSPORT
NOTC PORT NOTC
PORT PORT
TAGPORT
COSTAG
PORT
LNW78 LNW70 LNW78 LNW70 LNW78 LNW70
Packets
Altered?
5
No No No No
No
Maybe
Maybe untag’
VLANi d d user_pri ority
Maybe
VLANi d user_pri ority
Maybe
VLANid user_prior ity
Maybe
VLANi d
Maybe
VLANi d user_pri ority user_pri ority
Maybe
VLANid user_prio rity
1
The number of services at a port is the number of traffic conditioners used, except for the NOTC mode where there is 1 service with no traffic conditioner.
2
The number of services on a network is the total number of separate VLANids/default port tags allowed on the network in separate services times the number of traffic conditioners that are allowed for each VLANid/default port tag.
3
The maximum number of Classes of Service supported is the number that will be passed through any traffic conditioner on that port. For example, in 802.1TAG mode the PORT mode will allow all 4 CoS Levels to pass through a common traffic conditioner, whereas, in Transparent mode the PORT mode tags all traffic with the default CoS and therefore only a single
CoS is supported.
4
The traffic conditioning parameters shown are those available via TL1. In a practical sense fewer parameters are needed to provision the service
5
Packets are considered altered if the user packet that egresses the network at a Customer Port is not identical to the packet that ingressed the network at a Customer Port. Packets are generally altered in 802.1TAG mode due to the addition of a
VLAN tag or the alteration of the user_priority.
Metering (CIR and PIR)
Rate-shaped services offer a statistical multiplexing model that makes efficient use of shared bandwidth. DMX currently supports two of the primary forms of rate shaping. The two primary forms of rate shaping are rate limiting, and guaranteed rate services (plus various combinations of both).
Rate limiting is achieved using Peak Information Rate (PIR) provisioning. Guaranteed rate service is achieved using Committed
Information Rate (CIR) provisioning. PIR institutes a limit, or
“ceiling”, of maximum bandwidth to be allocated to a particular customer at any time. CIR, on the other hand, provides a guaranteed
A - 1 0 0
365-372-300
Issue 8.0 September 2006
Quality of Service
: Ethernet/SAN
minimum, or “floor” throughput even during periods of high congestion.
PIR
Burstable Bandwidth
CIR
Guaranteed Bandwidth nc-dmx2-032
When SLAs are written using CIR, Excess Burst Size (PBS), and
Committed Burst Size (CBS), they guarantee a CIR and CBS at a particular data rate. Traffic can be allowed to burst up to an excess burst size (PBS) beyond the CBS. This traffic will only be transmitted on a Best Effort basis. Any traffic above the PBS will be discarded. In this type of SLA, PIR is equal to CIR. The CIR must always be less than the maximum bandwidth that the port can support. If either CIR or
PBS is set to zero, service is effectively terminated.
The second method used to specify SLAs employs CBS, PIR, CIR, and
PBS. Burst Time can also be used in place of PBS. With SLAs of this sort, PIR, CIR, PBS, and CBS must be provisioned.
The figure below details the flow of traffic through the QoS packet with on the LNW70 and LNW78 circuit packs. The ingress and egress functions of the switch are explained further below the figure. Note that the DSCP Field has been added to the ingress port. DSCP functions only on the LNW70 in R6.0, though DSCP functionality on the
365-372-300
Issue 8.0 September 2006
A - 1 0 1
Quality of Service
: Ethernet/SAN
LNW78 is planned for a future release. On the egress functions side, the LNW78 supports 3 classes of service. So, for the LNW78, queue
"0" would be absent.
Ingress
Port
Ingress Filtering
– VLANid
Traffic Classification
– Determin CoS
Flow Classification
– Based on: Port, Tag,
CoS and DSCP field
(new for R6.0)
Figure A-37 Flow and Classifications of Traffic through QoS
Packet Switch
Ingress
Functions
Egress
Functions
Switch
Fabric
Traffic
Flow
Traffic
Conditioner
Metering
Policing
Counting
Marking
– with drop precedence
Remarking, if needed
Paremeters:
– Peak Information Rate (PIR)
– Committed Information Rate
(CIR)
– Excess Burst Size (EBS)
– Committed Burst Size (CBS)
CPU
– Slow Protocols
– Management
Output
Queues
– Dropper
– 4 Queues for
User Frames
– One Queue for
Management
Frames
0
1
2
3
Scheduling
Egress
Port
Management
A - 1 0 2
= The LNW78 supports
3 CoS. So, queue 0 does not exist on the
LNW78, but it does on the LNW70
JK-E-13.eps
The Ingress Port functions are as follows:
• Traffic Classification: Determines class of service (CoS), criteria can be 802.1p user priority, DSCP (R6.0), VLANid, or default value. Each class is mapped to an output queue. Internal management is classified into its own class.
• Flow Classification: A flow is a grouping of traffic based on certain criteria. The flow classification determines which Traffic
Conditioner will be used and multiple flows can be aggregated at a single traffic conditioner. Criteria is based on packet header, input port, flow, physical port, VLANid, DSCP (R6.0), and/or 802.1p user priority.
• Traffic Conditioner: Traffic Conditioners perform the metering, policing, marking, and counting of ingress packets. The parameters are PIR, CIR, PBS, and CBS. Metering measures the data rate which determines wether the packets conform to the settings for the user/port. Packets are marked according to conformance level (this is an internal marking). Policing discards
365-372-300
Issue 8.0 September 2006
Quality of Service
365-372-300
Issue 8.0 September 2006
: Ethernet/SAN
packets that exceed the PIR, PBS, or PBS (see Metering above).
The conformance level determines the drop precedence (DP) for non-conforming packets.
• Note: Flow Classification and Traffic Conditioning only apply to boundary ports. Once CoS and DP are determined at the boundary port, they are used consistently throughout the network. At internal ports, CoS and DP are then used to determine egress functions (i.e. dropping and queuing). For information on boundary and internal port demarcation, see the section below entitled Boundary versus Interior Ports.
The Egress Port functions are as follows:
• Dropping: Also known as Egress Queueing, Dropping is based on conformance level and the fullness of the queue. The drop function takes into account the total allocation queue for a particular port only. There are two drop methods employed by
DMX: Tail Drop and Weighted Random Early Detection
(WRED). The tail drop method discards all packets exceeding the maximum queue size. It uses only one parameter: Maximum
Queue Size. WRED dropping starts at the minimum threshold and increases up to the maximum. Two drop parameters govern
WRED: Minimum Threshold and Maximum Threshold. The CoS parameter, Maximum Drop Probability, is also provisionable in the WRED method. packets labeled with a higher drop precedence
(DP) will be discarded prior to those with a lower drop precedence.
• Scheduling: Scheduling allocates service for each queue. There are queues for each port: Expedited Forwarding (EF), Assured
Forwarding (AF). A combination of two algorithms controls scheduling. Packets in the Strict Priority queue are transmitted first. Strict Priority is used for EF queue. Weighted Round Robin
(WRR) ensures that the remaining bandwidth is allocated to each queue based on a provisioned weighting factor. WRR is used for the AF queues.
Egress functions support four classes of service (CoS). EF guaranteed low latency. There are three levels of AF offering various degrees of guaranteed delivery including best-effort.
Packets are handled differently depending on wether they originated from Boundary or Interior ports.
• Three Colors: RED: for packets that exceed peak rate limits.
Yellow: for packets that exceed committed rate limits.
Green: for packets within committed rate limits.
A - 1 0 3
: Ethernet/SAN
Ethernet Service Management
............................................................................................................................................................................................................................................................
Overview
The Ethernet services are managed by provisioning the following:
• Tagging (VLAN) mode
• Cross-connections
• LAN ports
• VCG (WAN) ports
• Virtual switches
• Quality of service (QoS) features.
• Performance monitoring.
For detailed information about provisionable parameters and their values, refer to Appendix B: Performance Monitoring.
Tagging (VLAN) modes
DMX supports the private line, transparent, and 802.1Q tagging modes.
Tagging modes are provisioned on a circuit pack basis. Changing tagging modes will impact service. For detailed information about the
tagging modes, refer to “Tagging Modes” (A-79) and the WaveStar
®
CIT on line help.
Cross-connections
The following types of cross-connections are used with Ethernet circuit packs.
• 1way
• 1wayPR
• 1way unswitched
For detailed information about supported cross-connections refer to
Chapter 5 of this document and the WaveStar
®
CIT on line help.
Cross-connections with SONET Layer Protection
All SONET protected services are implemented using 1way or 1wayPR cross-connections. They are used to form a pair of bidirectional links between a VCG port and one side of a SONET tributary. 1way or
1wayPR cross-connection use two VCGs on LNW66, LNW67, and
LNW68 Ethernet circuit packs and one VCG on all other Ethernet circuit packs (LNW63, LNW73, LNW73C, LNW74, LNW70, and
LNW78). 1way or 1wayPR cross-connections are described in
“Protected Tributaries” (A-35) . The use of VCG ports is summarized in
“VCG (WAN) ports” (A-109) .
A - 1 0 4
365-372-300
Issue 8.0 September 2006
Ethernet Service Management
: Ethernet/SAN
Cross-Connections without SONET Layer Protection
Services that are not protected by the SONET layer are provisioned using either 1way or 1way unswitched cross-connections.
1way cross-connections can be used to provide unprotected services on
BLSRs, only if the tributary (time slot) is provisioned to carry non-preemptible unprotected traffic (NUT). The BLSR tributary(s) must be provisioned for NUT before the cross-connection is established or protected services will be provided. A packet ring bandwidth could be split between working and protection (extra traffic) freeing up protected working bandwidth for other TDM services. 1way cross-connections can be used to provide unprotected services over
BLSR w/ NUT, but they are less efficient than 1way unswitched cross-connections.
1way unswitched cross-connections can be used to provision unprotected traffic on UPSRs. One cross-connection can be made between a VCG port and one side of the SONET ring, and the other can be made between the paired VCG and the other side of the SONET ring.
Unprotected cross-connections (1way unswitched) to UPSRs and
BLSRs w/ NUT are all provisioned independently per VCG beginning in R6.0.
This pairing of VCG ports and USPR unprotected cross-connections is described in “Unprotected Tributaries” (A-36) . The use of VCG ports is summarized in “VCG (WAN) ports” (A-109) .
Cross-Connection Types and Supported Configurations
The number of Private Line Services and Packet Rings an Ethernet circuit pack can support is dependent on the type of cross-connection used and whether SONET layer protection is used.
365-372-300
Issue 8.0 September 2006
A - 1 0 5
Ethernet Service Management
: Ethernet/SAN
The following table shows the cross-connection types and supported services.
Table A-6 Ethernet Private Line Services
SONET
UPSR
Ethernet Private Line Cross Connections
Ethernet Circuit Pack
Cross Connection
Type
LNW63 LNW64 LNW66
LNW6
7/68
LNW7
0
VT1.5 1WAYPR and 1WAY
STS-1 1WAYPR and
1WAY
N/A
4
N/A
8
N/A
1
N/A
1 or 2
2
N/A
8
STS-3c 1WAYPR and
1WAY
STS-12c 1WAYPR and 1WAY
STS-1 1WAY
UNSWITCHED
STS-3c 1WAY
UNSWITCHED
STS-12c 1WAY
UNSWITCHED
4
1
4
4
1
8
1
8
8
1
N/A
N/A
2
N/A
N/A
N/A
N/A
2
N/A
N/A
8
1
8
8
1
LNW7
1
N/A
12 or
24
2
8 or 16
N/A
12 or
24
2
8 or 16
N/A
2
2
LNW74
24
1
12-24
N/A
2
8 or 16
2
N/A
N/A
N/A
1+1
VT1.5 1WAY
STS-1 1WAY
STS-3c 1WAY
STS-12c 1WAY
VT1.5 1WAY
BLSR
3
STS-1 1WAY
STS-3c 1WAY
STS-12c 1WAY
A - 1 0 6
4
1
N/A
4
8
1
N/A
8
N/A
1
N/A
N/A
N/A
1 or 2
2
N/A
N/A
8
1
N/A
8
N/A
12 or
24
2
8 or 16
2
N/A
24
24
8 or 16
2
N/A
4
1
N/A
4
4
1
N/A
4
N/A
1
N/A
N/A
N/A
1 or 2
2
N/A
N/A
8
1
N/A
8
N/A
12 or
24
2
8 or 16
2
N/A
24
12-24
2
8 or 16
2
N/A
365-372-300
Issue 8.0 September 2006
Ethernet Service Management
SONET
BLSR
3 w/
NUT
Cross Connection
Type
Ethernet Private Line Cross Connections
LNW63 LNW64
Ethernet Circuit Pack
LNW66
LNW6
7/68
LNW7
0
VT1.5 1WAY
UNSWITCHED
STS-1 1WAY
UNSWITCHED
STS-3c 1WAY
UNSWITCHED
STS-12c 1WAY
UNSWITCHED
N/A
4
4
1
N/A
4
4
1
N/A
2
N/A
N/A
N/A
2
N/A
N/A
N/A
8
8
1
LNW7
1
N/A
12 or
24
2
8 or 16
N/A
2
: Ethernet/SAN
LNW74
N/A
N/A
N/A
N/A
1
Notes:
1. A mix of VT1.5, STS-1, & STS-3c connections allowed; Max of 336 VT1.5
(12 STS-1s) of VT1.5 cross connect capacity.
2. When using small or medium fabric MAINs, the small value reflects the capacity for function groups A, B, & C. Values for function groups D & G are represented by the larger value. When using all large fabric MAINs, ALL function groups support the larger value.
3. SONET protection is provided if NUT is not provisioned, and disabled if
NUT is provisioned.
365-372-300
Issue 8.0 September 2006
A - 1 0 7
Ethernet Service Management
: Ethernet/SAN
The following table shows the cross-connection types and supported services.
Table A-7 Ethernet Packet Ring Services
SONET
Ethernet Packet Ring Cross Connections
Cross Connection
Type
LNW66
Ethernet Circuit Pack
RPR
Ring
RPR
Pack
LNW67/
68
1
LNW70 LNW71 LNW74 LNW78
UPSR 1WAY UNSWITCHED 1
1WAYPR and 1WAY
1WAY
N/A
0 BLSR
BLSR w/ NUT
1WAY UNSWITCHED N/A
1 or 2
0 or 1
1
0 or 1
1
0 or 1
1
1
16
16
16
16
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
1
N/A
N/A
N/A
Notes:
1. When using small or medium fabric MAINs, the small value reflects the capacity for function groups A, B, & C. Values for function groups D & G are represented by the larger value. When using large fabric MAINs, ALL function groups support the larger value.
A - 1 0 8
365-372-300
Issue 8.0 September 2006
Ethernet Service Management
: Ethernet/SAN
LAN ports
VCG (WAN) ports
All LAN ports have characteristics that must be the same on both sides of a link. Some characteristics are strictly physical in nature. They can only be changed by using different equipment. Some examples of these characteristics are cable type (for example, twisted pair, fiber) and optical type (short reach, long reach). For more information about the
Ethernet circuit packs, refer to
“Ethernet/SAN Circuit Packs” (A-8)
.
The
Configuration > Provision Equipment
WaveStar
®
CIT command is used to provision LAN ports. For more information about the
Configuration > Provision Equipment
command and LAN port provisioning, refer to the WaveStar
®
CIT on-line help.
The
Configuration > Provision Equipment
WaveStar
®
CIT command is used to provision VCG (WAN) ports. For more information about the
Configuration > Provision Equipment
command and VCG (WAN) port provisioning, refer to the WaveStar
®
CIT on-line help.
365-372-300
Issue 8.0 September 2006
A - 1 0 9
Ethernet Service Management
: Ethernet/SAN
The following table shows the available VCG (WAN) ports available on Ethernet circuit packs.
Table A-8 VCGs Available on Ethernet Circuit Packs
Type
LNW63
LNW66
LNW67 and
LNW68
Ethernet Circuit Pack
Slot
6
Tagging
Mode
Transparent and 802.1Q
(Switched)
Private Line
Provisionable VCG Ports
LNW26,
LNW26B, and PWDM
Equivalent
OLIUs
All other
OLIUs
VCG1-VCG8 VCG1-VCG8
Comments
A-1, B-1, C-1,
D-1, G-1
A-1, B-1, C-1,
D-1, G-1
Private Line
A-1, B-1, C-1,
&D-1
Transparent and 802.1Q
(Switched)
VCG1-VCG4
VCG1, VCG2
VCG1-VCG4
VCG1, VCG2 See Note 2
A-1, B-1, C-1,
&D-1
A-1, B-1, C-1,
&D-1
A-1, B-1, C-1,
&D-1
A-1, B-1, C-1,
&D-1
A-1, B-1, C-1,
D-1, G-1
Private Line
VCG1
VCG1, VCG3
VCG1, VCG2
VCG1-VCG4
VCG1, VCG3
VCG1, VCG3
VCG1-VCG4
VCG1-VCG4
See Note 3
See Note 3
LNW70
LNW78
(RPR ports)
LNW78
(EoS ports)
A-1, B-1, C-1,
D-1, G-1
A-1, B-1, C-1,
D-1, G-1
A-1, B-1, C-1,
D-1, G-1
Transparent and 802.1Q
(Switched)
Transparent and 802.1Q
(Switched)
Transparent and 802.1Q
(Switched)
VCG1-VCG32
VCG1 and
VCG2
VCG17-
VCG22
VCG1-VCG32
VCG1 and
VCG2
VCG17-
VCG22
See Note 5
A - 1 1 0
365-372-300
Issue 8.0 September 2006
Ethernet Service Management
: Ethernet/SAN
Type
Ethernet Circuit Pack
Slot
6
Tagging
Mode
Provisionable VCG Ports
LNW26,
LNW26B, and PWDM
Equivalent
OLIUs
All other
OLIUs
Comments
LNW71
A-1, B-1, C-1,
&D-1
A-1, B-1, C-1,
&D-1
A-1, B-1, C-1,
&D-1
A-1, B-1, C-1,
&D-1
Private Line
STS-1 Mode
Private Line
STS-3c Mode
VCG1-VCG24
VCG1-VCG8
VCG1-VCG24
VCG1-VCG16
See Note 1
LNW74
4
A-1, B-1, C-1,
D-1, & G-1
A-1, B-1, C-1,
D-1, & G-1
Private Line
VCG1-VCG24 VCG1-VCG24
VCG1-VCG24 VCG1-VCG24
Notes:
1. All 24 VCGs are available only when unswitched cross-connections are used. Only 12 VCGs are available if protected cross-connections are used.
2. Only VCG1 is available when protected cross-connection is used.
3. VCG2 is not available when protected cross-connection is used on VCG1. VCG4 is not available when protected cross-connection is used on VCG3
4. Although the LNW74 can be used in slot G-1, only the optical ports are functional.
5. R7.0 adds support of EoS service on VCGs 17-22 of the LNW78. VCG port pairings are consecutive. Therefore, when VCG18 is not available when a protected cross-connection is used on VCG17 etc...
6. In Release 7.0 and going forward, when the VLF Main pack (LNW59) is used, DMX allows ethernet pack to be installed in Slot 1 and/or 2 of a function unit or growth slot (where applicable).
Certain circuit pack/slot equipage restrictions apply. For more information refer to Very Large
Fabric (VLF) Engineering Rules
. Prior to R7.0, and when VLF Mains are not used, ethernet packs can only be installed in Slot 1 of a function unit or growth slot.
365-372-300
Issue 8.0 September 2006
A - 1 1 1
Ethernet Service Management
Virtual switch
: Ethernet/SAN
A virtual switch is a logical grouping of LAN ports and VCG ports that share interconnect and share a common set of properties. A virtual switch may support one or more spanning trees; a spanning tree can only belong to one virtual switch.
A port (LAN or VCG) can only be assigned to one virtual switch at a time. On the LNW66/67/68 packs VLANs (802.1Q mode) and port tags (transparent mode) that are assigned to a virtual switch cannot be assigned to another virtual switch on the same circuit pack.
The LNW70 circuit packs can support a maximum of 16 virtual switches on each circuit pack (LNW66/67/68 support 2).
The following WaveStar
®
CIT commands support virtual switch provisioning:
•
Configuration > Data > Create a Virtual Switch
•
Configuration > Data > Delete a Virtual Switch
•
Configuration > Data > Provision a Virtual Switch
For more information about provisioning virtual switches and the
WaveStar
®
CIT commands, refer to the WaveStar
®
CIT on-line help.
Quality of service (QoS)
The following Quality of Service (QoS) parameters are provisionable using the WaveStar
®
CIT.
• Default port priority (high, low, NA)
• Rate Policing (PIR)
• Peak information rate (PIR) is provisioned on a VLAN/port TAG or on a LAN port basis for protected private line.
• Burst size length
• Credit interval for adding tokens to the token buckets used by the
PIR
For more information about Quality of Service, refer to
“QoS services (LNW70 and LNW78)” (A-90)
.
For more information about the provisionable QoS parameters, refer to the WaveStar
®
CIT on line help.
Performance monitoring
Each Ethernet port has associated performance monitoring parameters and counters. The counters are provided for incoming and outgoing frames. For detailed information about Ethernet performance monitoring parameters, refer to Appendix B, “: Performance
Monitoring” .
A - 1 1 2
365-372-300
Issue 8.0 September 2006
: Ethernet/SAN
Ethernet Service Configurations
............................................................................................................................................................................................................................................................
Overview
DMX supports the Ethernet services shown in the following table.
Table A-9 Supported Ethernet Services
Service
Private
Line
Private
LAN
Virtual
Private
LAN
Ethernet
Virtual
Private
LAN
VCGs (per
Circuit Pack)
1 Private Line per VCG
Protected
1 Private Line per VCG
Unprotected
1 Subscriber per
VCG
Several
Subscribers per
VCG
Ethernet
Ports
SONET
Capacity
Dedicated
Dedicated
Dedicated
Dedicated or Shared
Dedicated
Dedicated
Dedicated
Shared
Tagging
Mode
Private
Line
(No tag)
Ethernet
Forwarding
(Switching) based on
No Ethernet switching.
Point-to-Point connection is preconfigured.
Transparent No Ethernet switching.
802.1Q
Point-to-Point
Transparent Stacked VLAN Tag
802.1Q
Original or Port
Default VLAN Tag
Transparent Stacked VLAN Tag
802.1Q
Original or Port
Default VLAN Tag
Transparent Stacked VLAN Tag
1 Subscriber per
LAN port
Dedicated Shared
802.1Q
Original or Port
Default VLAN Tag
365-372-300
Issue 8.0 September 2006
A - 1 1 3
Ethernet Service Configurations
: Ethernet/SAN
The following table shows the typical Ethernet service configurations.
Table A-10 Typical Ethernet Service Configurations
Service
Private Line
Private
LAN
Virtual
Private
LAN
Virtual
Private Line
Service
Protection
SONET
Spanning
Tree
Ring
Type
Yes
No
Yes
Not
Allowed
UPSR
Cross-Connect
Type
1wayPR, 1way
UPSR 1way unswitched
BLSR 1way
No
No Yes
BLSR w/
NUT
1way unswitched
UPSR 1way unswitched
BLSR w/
NUT
1way unswitched
UPSR 1way unswitched
Tagging
Mode
Private Line
Transparent or 802.1Q
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
BLSR w/
NUT
1way unswitched
UPSR 1wayPR, 1way
UPSR 1way unswitched
BLSR 1way
BLSR w/
NUT
1way unswitched
802.1Q
Transparent or 802.1Q
A - 1 1 4
365-372-300
Issue 8.0 September 2006
Ethernet Service Configurations
: Ethernet/SAN
Private line service
Private line service is a point-to-point service with two dedicated LAN ports and dedicated SONET capacity. Because it is a point-to-point service, spanning tree protection is not used. Protection is provided at the SONET layer only.
Ethernet private line service can be provided over SONET UPSRs. The following figure shows an example of private line service with protection provided by a SONET UPSR.
Figure A-38 Ethernet Private Line Service over Protected UPSR
Ethernet
Switch
V4 V3 V2 V1
Main 2 Main 1
Main 1
Main 2
L1
V1
L2
Ethernet
Switch
V2
V3
V4
V4
L1
V3
Ethernet
Switch
V2
L2
V1
Main 2 Main1
Main 2 Main 1
V1 V2 V3 V4
Ethernet
Switch
Type of Ring
- UPSR
Type of Cross-Connection
- 2Way PR
Transport Protection
- UPSR Switching
= Traffic transmitted clockwise around the ring
= Traffic transmitted counter-clockwise around the ring
MA-DMX-367
365-372-300
Issue 8.0 September 2006
A - 1 1 5
Ethernet Service Configurations
: Ethernet/SAN
The following figure shows two independent unprotected links.
External or subscriber equipment can use these links to either provide two paths between equipment or separate paths for link aggregation.
Figure A-39 Dual Unprotected Ethernet Private Line over UPSR or
BLSR
Ethernet
Switch
V4 V3 V2 V1
Main 2 Main 1
External or
Subscriber
Equipment
L1
V1
Ethernet
L2
Switch
V2
V3
V4
Type of Ring
- UPSR or BLSR
Type of Cross-Connection
- Multipoint (UPSR and BLSR)
Transport Protection
- Externally Protected
Main 1
Main 2
Independent
Link (Services)
Main 1 Main 2
= Working Channels
V1 V2 V3 V4
Ethernet
Switch
L1 L2
External or
Subscriber
Equipment
MA-DMX-368
A - 1 1 6
365-372-300
Issue 8.0 September 2006
Ethernet Service Configurations
Private LAN, Virtual Private
LAN, and Virtual Private
Line services
: Ethernet/SAN
In Private LAN service, LAN ports and SONET capacity are dedicated to one subscriber. In Virtual Private LAN service, several subscribers share SONET capacity and can share LAN ports. Traffic is segregated by its VLAN/port TAG. Virtual Private Line service is subset of
Virtual Private LAN service, where the subscriber is given a point-to-point service with dedicated LAN ports.
Protection can be provided either by packet layer spanning tree protocols, by the SONET layer, or by both. The network could also use tributaries provisioned for nonpreemptible unprotected traffic (NUT).
If NUT is provisioned, the Ethernet traffic is protected by the spanning tree protocol.
The following figure shows multipoint cross-connections used to form a packet ring.
Figure A-40 Spanning Tree Protected Private LAN and Virtual
Private LAN Services
L2
L1
Ethernet
Switch
V4 V3 V2 V1
365-372-300
Issue 8.0 September 2006
Main 2 Main 1
Main 1
Main 2
L1
L2
V1
Ethernet
V2
Switch
V3
V4
V4
L1
V3
Ethernet
V2
Switch
L2
V1 Main 2
Main 1
Extra traffic used for BLSR (blue)
Main 1 Main 2
Type of Ring
- UPSR or BLSR
Type of Cross-Connection
- Multipoint (UPSR and BLSR)
Transport Protection
- Spanning Tree
V1 V2 V3 V4
Ethernet
Switch
L1 L2
MA-DMX-371
A spanning tree is required to eliminate Ethernet forwarding loops. The
Ethernet traffic is protected by the spanning tree. In UPSRs, an additional packet ring could be supported on VCG 3 and VCG 4 protected by it's spanning tree.
A - 1 1 7
Ethernet Service Configurations
: Ethernet/SAN
Virtual Private Line LNW70
The figure below depicts the traffic flow of multiple virtual private lines in transparent mode over shared media (optical fiber). For more information on private lines in transparent mode, refer to the
Transparent mode
section above. For information on Boundary and
Interior port demarcation, refer to the section
Boundary versus Interior
Ports
above.
Figure A-41 Virtual Private Line with LNW70
Trafmgmtmd=COSPORT
VLANid=55
PBX
VoIP
LAN
Foundry
®
Customer 4
Customer 1
- Trafmgmtmd=PORT
VLANid=32
Metropolis
®
DMX
VLANid=66
Customer 3
Trafmgmtmd=PORT
Metropolis
®
DMX
OC12/48/192
UPSR/BLSR
Metropolis
DMX
®
Boundry Port
Interior Port
VLANid=55
Trafmgmtmd=COSPORT
Metropolis
®
DMX
VLANid=32
Customer 1
- Trafmgmtmd=PORT
Foundry
®
Customer 4
PBX
VoIP
LAN
DMX = Metropolis
®
DMX Access Multiplexer
JK-E-11.eps
VLANid=66
Customer 3
Trafmgmtmd=PORT
A - 1 1 8
365-372-300
Issue 8.0 September 2006
Ethernet Service Configurations
LAN Service with LNW70
: Ethernet/SAN
The figure below depicts the traffic flow of multiple VLANs over shared media (optical fiber). For more information on VLANs, refer to the
Private LAN, Virtual Private LAN, and Virtual Private Line services section above. For information on Boundary and Interior port demarcation, refer to the section
Boundary versus Interior Ports
above.
Figure A-42 LAN Service with LNW70
VLANid=55
PBX
VoIP
LAN
Foundry
®
Customer 4-
Trafmgmtmd=COSPORT
Customer 2 - Trafmgmtmd=PORT
VLANid=27
Router
Customer 1
Customer 2
Customer 3
VLANid=32
VLANid=27
VLANid=66
Metropolis
®
DMX
Metropolis
®
DMX
OC12/48/192
UPSR/BLSR
Metropolis
DMX
®
Trafmgmtmd=TAGPORT
Boundry Port
Interior Port
VLANid=55
Trafmgmtmd=COSPORT
Metropolis
®
DMX
VLANid=32
Customer 1 - Trafmgmtmd=PORT
Foundry
®
Customer 4
PBX
VoIP
LAN
®
DMX = Metropolis DMX Access Multiplexer
JK-E-11.eps
VLANid=66
Customer 3
Trafmgmtmd=PORT
365-372-300
Issue 8.0 September 2006
A - 1 1 9
Ethernet Service Configurations
: Ethernet/SAN
RPR Ethernet Transport with LNW78
The figure below shows a ring of DMX nodes supporting an RPR ring.
The center node has an RPR LNW78 card in slot A1 and OC-3/12/48 cards in slots B1 and B2. The LNW78 card sets up a RPR instance, connecting LAN ports on the LNW78 to a port on a card in the MAIN slot of the shelf. The other VCG port in the LNW78 is able to connect to the other MAIN slot, or to another function slot in the same shelf.
This is accomplished by way of a hairpin cross-connect. In the figure below, the hairpin cross-connect is between the LNW78 in A1 and another LNW78 card in function group B. Dotted lines are used to show the west bound port could be connected to the MAIN card or to
another function group via a hairpin cross-connect. See “Direction
rings.
Figure A-43 RPR Packet Ring and Hairpin to Subtending Ring with LNW78
Metropolis
®
DMX
West
East
OC-12/48/192 UPSR/BLSR
West
Metropolis
®
DMX
East
DMX
West
LNW78 RPR Pack
East
West
A1
B
L
A
N
K
B1 B2
1000BASE-X
RPR
East
West
JK-E-18.eps
A - 1 2 0
365-372-300
Issue 8.0 September 2006
Ethernet Service Configurations
: Ethernet/SAN
The figure below demonstrates 2 separate RPR characteristics. The top portion of the figure is meant to show how the direction of traffic on an
RPR ring travelling between different nodes can be reversed if necessary. In the course of connecting multiple SONET rings within a single RPR ring over multiple SONET rings, the direction of traffic flow may need to be corrected. Just as with SONET rings, RPR requires that east facing nodes always be connected to west facing nodes and vice versa. If the direction of traffic needs to be switched at some point in the
RPR ring, it can be done with 1WAY cross-connections by connecting
F1 to V2 instead of the usual F1 to V1, etc.
Figure A-44 Direction Reversal in UPSRs Joined via RPR and
Daisy Chained RPR Nodes within One NE
E
W
M2
W
E
M1
E
M1
W
M2
F2
M1
F1
M1= MAIN 1
M2= MAIN 2
F1= Function Group 1
F2= Function Group 2
M1
E
V1
V2 V1
M1
M2
M2
V2
W
E
W
365-372-300
Issue 8.0 September 2006
C1
D1
JK-E-19.eps
The bottom portion of the figure above demonstrates the ability of a
DMX equipped with more than one LNW78 to daisy chain multiple cards in the same shelf on one RPR ring. In the figure above, slot C1 and D1 both contain LNW78 cards. Either an OC-48 or OC-192 card
A - 1 2 1
Ethernet Service Configurations
: Ethernet/SAN
would be is slots M1 and M2. The RPR ring is on the UPSR ring of M1 and M2. M1 connects to V1 in C1 as usual. V2 however connects to V1 in D1. V2 in D1 connects to M2 to complete the ring. In this way 2
RPR nodes are instantiated in one DMX shelf, making 12 LAN ports available to the RPR ring.
With this capability/configuration, the RPR ring hosted by the LNW78 in slot C1 is connected to the RPR ring being hosted by slot D1 and both are connected to the main SONET ring being hosted by the
OC-48/192 packs in the main slots.
A - 1 2 2
365-372-300
Issue 8.0 September 2006
Ethernet Service Configurations
: Ethernet/SAN
RPR interconnect and LAN port aggregation with
LNW78 EoS functionality
The figure below shows two RPR rings connected via an EoS link. The rings are linked together through EoS VCGs LNW78 located on different shelves. The Eos ports on the LNW78(s) connect the Ethernet switches located on the packs, thereby providing a bridge between the two RPR rings. This eliminates the need to use physical LAN ports, additional Ethernet circuit packs, PTMs (SFPs), and associated cabling to establish the interconnect. On each shelf shown below traffic is mapped to EoS ports. The EoS ports are then connected to an optical interface, in this case, via a hairpin connection. The two shelves are connected by an optical ring (or 1+1). Ethernet traffic can now flow between RPR rings.
Figure A-45 RPR Packet Ring interconnect via EOS VCG with
LNW78 (multi-node interconnect)
RPR Ring 1
Metropolis
®
DMX
LNW78
Metropolis
®
DMX
LNW78
OC-n
LNW78
Metropolis
®
DMX
LNW78
Local Hairpin – LNW78 to
Optical Port Unit
OC-n
Optical Shelf
Interconnect
Local Hairpin – LNW78 to
Optical Port Unit
Metropolis
®
DMX
LNW78
LNW78
OC-n
Metropolis
®
DMX
LNW78
RPR Ring 2
Metropolis
®
DMX
LNW78
365-372-300
Issue 8.0 September 2006
MA-DMXAPG-051
A - 1 2 3
Ethernet Service Configurations
: Ethernet/SAN
Metropolis
®
DMX
LNW78
As the figure below shows, the link between the two rings can be established using LNW78s located on the same shelf. In this example, the two RPR rings reside on a single shelf. As in the multi-NE shelf example, Ethernet traffic is mapped to EoS ports. The difference in this figure is that the EoS ports on each card are connected to each other via an internal hairpin.
Figure A-46 RPR Packet Ring interconnect via EOS VCG with
LNW78 (single-node interconnect)
RPR Ring 1
Metropolis
®
DMX
LNW78
OC-n
LNW78
LNW78
Local Hairpin –
LNW78 to LNW78
Metropolis
®
DMX
LNW78
Metropolis
®
DMX
LNW78
OC-n
Metropolis
®
DMX
LNW78
LNW78
RPR Ring 2
®
DMX = Metropolis DMX Access Multiplexer
MA-DMXAPG-052
RPR ring interconnect via EoS connects multiple rings without making them the same ring. This is advantageous because all functions of the rings remain separate, including node-based bandwidth allocation around the RPR as governed by the fairness algorithm.
A - 1 2 4
365-372-300
Issue 8.0 September 2006
Ethernet Service Configurations
: Ethernet/SAN
The configuration pictured below functions in a similar fashion to
TransMUX hub-and-spoke application, with EoS ports terminating services originating on other Ethernet packs. Typically these services are in NOTAG mode. The EoS ports are configured as LAN ports with
trafmgmtmd set to PORT or COSPORT and vlantagmd set to 802.1Q or Transparent mode. The received remote traffic has no added tags, and no CoS or drop precedence marking. Therefore it is received just as it originated at the remote LAN port. Tags are added at the EoS port ingress according to the vlantagmd command. This traffic is typically added to an RPR ring destined for NE-local LAN ports at the hub node.
Figure A-47 Remote LAN port aggregation/RPR interconnect
SONET
6 Eos VCG
With Rate Controls
RPR Ring
Metropolis
®
DMX
plore
VLNC15
Metropolis
®
DMX
plore
VLNC15
Metropolis
®
DMX
LNW70
Metropolis
®
DMX
tend
LNW74
RPR VCG
LNW78
RPR Port Unit
RPR VCG
Metropolis
®
DMX
tend
LNW74
DMX
plore
= Metropolis
®
DMX
plore
Access Multiplexer
DMX
tend
= Metropolis DMX
tend
Access Multiplexer
LNW78
RPR Port Unit
LNW78
RPR Port Unit
LNW78
RPR Port Unit
MA-DMXAPG-049
365-372-300
Issue 8.0 September 2006
A - 1 2 5
Ethernet Service Configurations
: Ethernet/SAN
The NE-local LAN ports aggregation/interconnect configuration listed below functions similar to the Remote LAN Ports configuration described above except that the connections to Ethernet pack(s) providing LAN ports is via backplane hairpin(s).
Figure A-48 NE-local LAN port aggregation/interconnect
MAIN MAIN
Aggregated Traffic
From a SW Port Card
RPR VCG
EoS VCG
OC-3/12/48
LNW78 LNW74 LNW70
Local LNW78 Ports
Remote Private Line via
Optical Ring
OC-n
Local 10/100
Ports
Local 100/1000
Mbps Ports
Additional Local LAN
Ports to RPR
MA-DMXAPG-050
A - 1 2 6
365-372-300
Issue 8.0 September 2006
: Ethernet/SAN
SONET-Based Distance Extensions for
ESCON/FICON/Fibre-Channel Services
............................................................................................................................................................................................................................................................
Overview
This section details the functionality of SONET-based SAN distance extension supported by the LNW73. For other information on the functionality of the LNW73, refer to the following sections within this
appendix: “Ethernet/SAN Circuit Packs” (A-8) , and
“Differential
Delay Buffers” (A-34) .
ESCON Design Guidelines
ESCON services enter DMX or DMXtend through ESCON PTM attached to LNW73 plugin circuit and are routed out OC48/192
SONET interfaces from SONET plugins (in slot main-1 (and main-2, if protection is desired)). The SONET signal can be routed through any number of intermediate SONET systems (including none) and terminates into another DMX or DMXtend to provide a network transport of ESCON services. A LNW73 may be placed in slots fn-a-1,fn-b-1,fn-c-1, fn-d-1 or growth-1 (5 slots) for DMX and in slots fn-d-1 and growth-1 (2 slots) for DMXtend. Up to 4 ESCON services may be provided in a single LNW73 plugin, each service requiring 4
STS-1 bandwidth reserved in the SONET domain. A DMX/OC48 system can provide 12 ESCON services (limited by SONET bandwidth).
A DMX/OC192 system can provide 20 ESCON services (limited by the number of slots that may be equipped with LNW73) A
DMXtend/OC48 system may provide 8 ESCON services (limited by the number of slots that may be equipped with LNW73).
Reliability/Line and Pack Protection Options
To protect against SONET network failures and main pack failures,
DMX can be equipped with redundant circuit packs in both main slots and can be provisioned for UPSR or BLSR protection. To protect against SONET network failures and main pack failures, DMXtend can be equipped with redundant circuit packs in both main slots and be provisioned for UPSR protection. Using SONET protection significantly increases the reliability of individual end-to-end ESCON services.
365-372-300
Issue 8.0 September 2006
A - 1 2 7
A - 1 2 8
: Ethernet/SAN
Circuit Pack Equipage and Provisioning
Each LNW73 used must be set to select the pack type of ESCON (see
ED-EQPT). Each port to be used must be equipped with a Lucent specified ESCON Pluggable Transmission Module (PTM). A PTM is similar in functionality to a GBIC pluggable unit. If a Virtual
Concatenated (VCAT) signal format is desired, the
ED-DPORT-DATA command is used to select it.
Circuit Bandwidth Choices
A full rate ESCON service may be provisioned as a SONET STS-1-4v
(VCAT), STS-3c-2v(VCAT) or a STS-12c Contiguously Concatenated
(CCAT). The most bandwidth efficient is STS-1-4v.
Interface Specifications to ESCON interfaces
DMX/DMXtend use standards compatible PTM modules. Refer to
Chapter 10 for optical specification, loss budget, connector and fiber type requirements.
Distance Limitations/Transmission Delay Engineering
Distance between the ESCON equipment and the DMX/DMXtend are typically limited by the interface link specification of the ESCON interface.
The total distance allowed including the SONET extension is typical a function of the delay requirements of the ESCON application.
Synchronous ESCON applications typically suffer performance droop if the application is subjected to more than 100 microseconds of one way transmission delay (the equivalent of delay through 20 km of fiber). For planning purposes, each DMX adds the equivalent 25 microseconds or 5 km of fiber. Therefore, synchronous ESCON applications would suffer droop if the total actual fiber distance (adding the ESCON to DMX and DMX to DMX links) is more than 10 km.
Asynchronous ESCON applications are much more tolerant to transmission delay, typically able to function at delays of 1000 microseconds (200 km) or longer. Each DMX/DMXtend or other
SONET system in the path of such a network would add the equivalent of 5 km of fiber.
365-372-300
Issue 8.0 September 2006
: Ethernet/SAN
Full-rate FICON/FC Design
Guidelines
FICON/FC services enter DMX or DMXtend through FICON/FC PTM attached to LNW73 plugin circuit is routed out OC48/192 SONET interfaces from SONET plugin (in slot main-1 (and main-2, if protection is desired)).
The SONET signal can be routed through any number of intermediate
SONET systems (including zero) and terminates into another DMX or
DMXtend to provide a network transport of a FC/FICON service.
A LNW73 may be placed in slots fn-a-1,fn-b-1,fn-c-1, fn-d-1 or growth-1 (5 slots) for DMX and in slots fn-d-1 and growth-1 (2 slots) for DMXtend.
Up to 2 full rate 1G FICON/FC services (or one 2G FICON/FC service) may be provided in a single LNW73 circuit pack, each service requiring 19 STS-1 or 6 STS-3c bandwidth units reserved in the
SONET domain (37 STS-1 or 12 STS-3c for 2G FICON/FC).
So, when operating in asynchronous Fibre Channel (FC) mode, 2 ports are available at 2Gbps FC, or 4 ports at 1Gbps FC, or 1 port at 2Gbps
FC and 2 ports of 1Gbps FC. When operating in synchronous FC mode,
1 port is available at 2Gbps FC, or 2 at 1Gbps FC.
A DMX/OC48 system can provide 2 full rate FICON/FC 1G services
(limited by SONET bandwidth).
A DMX/OC192 system can provide 10 FICON/FC 1G services
(limited by the number of slots that may be equipped with LNW73).
A DMXtend/OC48 system may provide 2 full rate 1G FICON/FC services (limited by SONET bandwidth).
Buffer-to-buffer credits are handled exclusively by FICON/FC switches/devices.
Reliability/Line and Pack Protection Options
To protect against SONET network failures and main pack failures,
DMX can be equipped redundant circuit packs in both main slots and be provisioned for UPSR or BLSR protection.
To protect against SONET network failures and main pack failures,
DMXtend can be equipped SONET plugins in both main slots and be provisioned for UPSR SONET Protection.
Using SONET Protection dramatically increases the reliability of end to end FICON/FC services.
365-372-300
Issue 8.0 September 2006
A - 1 2 9
A - 1 3 0
: Ethernet/SAN
Circuit Pack Equipage and Provisioning
Each LNW73 used must be set to select the pack type of FICON/FC
(see ED-EQPT). Each port to be used must be equipped with a Lucent specified FC/FICON Pluggable PTM. A PTM is similar in functionality to a GBIC pluggable unit. If a VCAT signal format is desired, the ED-DPORT-DATA command is used to select it.
Circuit Bandwidth Choices
A full rate 1G FICON/FC service may be provisioned as a SONET
STS-1-19v (VCAT), STS-3c-6v(VCAT). The most bandwidth efficient is STS-3c-6v. A full rate 2G FICON/FC service may be provisioned as a SONET STS-1-37v (VCAT), STS-3c-12v (VCAT). The most bandwidth efficient is STS-3c-12v.
Interface Specifications to FICON/FC interfaces
DMX/DMXtend use standards compatible PTMs. The same PTM works for both FICON and FC and both 1G and 2G. Refer to Chapter
10 for optical specification, loss budget, connector and fiber type requirements.
Distance Limitations/Transmission Delay Engineering
Distance between the FICON/FC equipment and the DMX/DMXtend are typically limited by the interface link specification of the
FICON/FC interface.
The total distance allowed including the SONET extension is typically a function of the delay requirements of the FICON/FC application.
Synchronous FICON/FC applications typically suffer performance droop if the application is subjected to more than 600 microseconds of one way transmission delay (the equivalent of delay through 120 km of fiber). Refer to your particular client equipment engineering rules for distance limitations. For planning purposes, each DMX adds the equivalent 25 microseconds or 5 km of fiber.
Asynchronous FICON/FC applications are much more tolerant to transmission delay, typically able to function at delays of 1000 microseconds (200 km) or longer. Many newer FC switches today offer extended buffer credits for asynchronous applications that allow up to
3600 microseconds of delay without performance droop. Each
DMX/DMXtend or other SONET system in the path of such a network would add the equivalent of 5 km of fiber.
365-372-300
Issue 8.0 September 2006
: Ethernet/SAN
FC/FICON Services-Extended Distances- BB Credits managed in
DMX/DMXtend
To extend asynchronous FICON/FC applications beyond the buffer to buffer credit limits of the attached FC Switches, DMX and DMXtend can be provisioned to manage the BB Credits and eliminate performance droop related to insufficient BB credit across the network.
This implementation is based on the ITU G.7041 and T11
FC-BB-3_GFPT standards work and provides sufficient credits for full performance at 2500 km for 2G services in R5.1.1.
To use this mode, the gfptype (in the ED-DPORT-DATA command) must be provisioned to ASYNC-FC (even if it is a FICON service).
Buffer credits are automatically adjusted within DMX/DMXtend and no additional provisioning required. Attached FICON/FC devices should be provisioned to use for R_RDY flow control (as opposed to proprietary Inter-Switch Link (ISL) flow control schemes.
Illustrative examples of some FC switch configurations are provided below.
EMC Certification
DMX is pursuing interoperability certification with established storage hardware vendors such as IBM and EMC. Interoperability testing is currently underway with EMC, with a target date of the end of 2006.
To achieve EMC certification, DMX has been tested with various
FC/FICON switches used with EMC storage equipment. Presently,
DMX has completed testing with the Brocade Silkworm 3800 and
2250, the McData Sphereon 4500, and Cisco MDS 9120 and MDS
9126. This testing has yielded some simple guidelines that need to be followed to ensure smooth interworking between DMX and the
FC/FICON switches listed above.
Refer to the sections below for these SAN interworking guidelines.
365-372-300
Issue 8.0 September 2006
A - 1 3 1
: Ethernet/SAN
General FC/FICON
Equipment port configuration for connection to
DMX/DMXtend
Please use the following guidelines to ensure interoperability between
FC/FICON equipment and DMX/DMXtend.
To assure minimal link start up and recovery times, the following configurations are recommended for all ports attached to
DMX/DMXtend:
• Configure port speed to match application: I.e. use 1G or 2G mode instead of auto-negotiate mode.
• Configure ports to not waste time trying to determine if DMX is arbitrated loop port type
To use buffer credits in DMX/DMXtend when gfptype is set to
async-FC, configure ports to use R_RDY mode buffer credit management instead of proprietary link buffer credit management.
If compression is desired on DMX/DMXtend and gfptype is set to
async-FC, set the number of link buffer credits to 8 or less, otherwise the operational state of compression will stay disabled.
Brocade interworking examples
Please use the following guidelines to ensure interoperability between the specified Brocade equipment and DMX/DMXtend.
Brocade Silkworm 3800:
Perform the following tasks on all ports connected to the
DMX/DMXtend:
• Through the CLI, use the portcfgSPEED {port num}, {1 or 2, not
0}
• Then use the portcfgGPORT {portnum}, {1, not 0}
In addition, to use buffer credits on DMX/DMXtend when gfptype is set to async-FC, use portcfgISLMODE {portnum}, {1, not 0}.
To use compression on DMX/DMXtend when gfptype is set to
async-FC, use switchdisable, then use the configure command to set
fabric.ops.BBCredit to 8 or less.
Brocade Silkworm 2250:
Perform the following tasks on all ports connected to the
DMX/DMXtend:
• Through the CLI, use the portcfgSPEED {port num}, {1 or 2, not
0}
• Then use the portcfgGPORT {portnum}, {1, not 0}
A - 1 3 2
365-372-300
Issue 8.0 September 2006
: Ethernet/SAN
In addition, to use buffer credits on DMX/DMXtend when gfptype is set to async-FC, use switchdisable, then use the configure command to set fabric.ops.longdistance=1
To use compression on DMX/DMXtend when gfptype is set to
async-FC, use switchdisable, then use the configure command to set
fabric.ops.BBCredit to 8 or less.
Cisco MDS 9120 or MDS
9216 interworking examples
Please use the following guidelines to ensure interoperability between the Cisco MDS 9120 or MDS 9216 equipment and DMX/DMXtend.
Perform the following tasks on all ports connected to the
DMX/DMXtend:
• Through the GUI, click on FC port, set admin Speed to 1Gb or
2Gb not auto
• Through the GUI, click on FC port, set admin Mode to E or TE, not auto
In addition, to use buffer credits on DMX/DMXtend when gfptype is set to async-FC, it is important to note that Cisco uses ISL mode as
R_RDY mode by default.
To use compression on DMX/DMXtend when gfptype is set to
async-FC, through the GUI, click on FC port, then click on BBCredit and then set admin BBCredit to 8 or less.
MC Data Sphereon 4500 interworking examples
Please use the following guidelines to ensure interoperability between the MC Data Sphereon 4500 equipment and DMX/DMXtend.
Perform the following tasks on all ports connected to the
DMX/DMXtend:
• Through the GUI, click on Configure, then click on ports, on the appropriate ports, set Speed to 1Gb/sec or 2Gb/sec
• Through the GUI, click on Configure, then click on ports, on the appropriate ports, set Type to E port
In addition, to use buffer credits on DMX/DMXtend when gfptype is set to async-FC, it is important to note that Sphereon uses ISL mode as R_RDY mode by default.
To use compression on DMX/DMXtend when gfptype is set to
async-FC, set any port numbered "4" or higher to use 5 credits (ports
0-3 use 12 credits).
365-372-300
Issue 8.0 September 2006
A - 1 3 3
: Ethernet/SAN
A - 1 3 4
365-372-300
Issue 8.0 September 2006
B: Performance Monitoring
Overview
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Purpose
This section lists and describes performance monitoring parameters, data storage, thresholds, and TCA transmission.
365-372-300
Issue 8.0 September 2006
B - 1
Overview
: Performance Monitoring
Contents
The following performance monitoring information is included in this section:
Introduction to Performance Monitoring
DS3 Performance Monitoring Parameters
DS1 Performance Monitoring Parameters
Ethernet/SAN Performance Monitoring
B - 2
365-372-300
Issue 8.0 September 2006
: Performance Monitoring
Introduction to Performance Monitoring
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Definition
Performance monitoring (PM) is the in-service, non-intrusive monitoring and reporting of transmission quality.
PM helps proactive maintenance detect and correct degrading signal conditions that are not yet severe enough to initiate protection switching or alarming.
Proactive maintenance
Proactive maintenance is the process of detecting degrading conditions that are indicative of an impending hard or soft failure, but not severe enough to initiate alarming.
Data registers
Reactive maintenance
Hard and soft failures result in reactive maintenance.
The following table lists the data registers that are provided for all performance monitoring parameters.
Table B-1 Data Registers
15-Minute Registers
One current
One previous
31 most recent
1-Day (24-Hour) Registers
One current
One previous
NA
DMX retrieves and reports the contents of any parameter storage register. The WaveStar
®
CIT may be used to initialize (set to zero) the current 15-minute and/or current 1-day registers locally or remotely.
This capability enables the user to verify that a repair to a failed facility was successful.
The following events also initialize the data registers to zero:
• System reset is performed
• Performance monitoring is restarted (PST parameter fluctuates between IS and AUTO or NMON)
• INIT-REG (Initialize Register) TL1 command is executed
• Facility or terminal loopback is removed
• Transmission test is completed.
365-372-300
Issue 8.0 September 2006
B - 3
Introduction to Performance Monitoring
: Performance Monitoring
How registers are updated
The two registers (15 min. and day registers) are updated in the following manners:
15-minute registers
The registers are updated with a push-down methodology. At 0, 15, 30, and 45 minutes on the system clock, the contents of the 30th recent register is moved to the 31 st
recent register. The contents of each of the other recent registers are moved to the next higher register. The contents of the previous register are moved to the first recent register.
The contents of the current register are moved to the previous register.
The new measured value is placed in the current register.
Day registers
At day boundaries (midnight as defined by the local time/date function), the current day register is written to the previous day storage register and the current day register is set to zero. The day boundary is midnight by default, but may be provisioned to a different time.
PM scheduling
Performance monitoring can be scheduled to provide quarter hour and daily reports beginning at different time intervals. In order to schedule
PM reports, PM messaging must be enabled and you must use the
WaveStar
®
CIT TL1 cut-through mode or the TL1 Command Builder.
PM cannot be scheduled via the WaveStar
®
CIT Graphical interface.
Enabling/disabling performance monitoring
Performance monitoring can be enabled/disabled for DS1 ports, DS3 ports, E1 ports, EC-1 ports, STS-n paths, VT1.5 paths, VC-12 paths, and OC-N lines.
DS1 ports
Performance monitoring is enabled/disabled on a DS1 port basis using the Primary State (PST) parameter of the
Configuration > Provision
Equipment
command.
When the PST parameter is provisioned as AUTO and a valid signal
(non DS1 LOS) is detected, the PST parameter automatically transitions to the IS (in service) state. This initializes the data registers and enables DS1 line and path performance monitoring on the port.
When the PST parameter is provisioned as NMON or AUTO (with no valid input signal detected), DS1 line and path performance monitoring is disabled on the port.
B - 4
365-372-300
Issue 8.0 September 2006
Introduction to Performance Monitoring
: Performance Monitoring
On the TransMUX DS1 interfaces, "Receives a good signal" is defined as absence of
DS3: LOS, LOF, AIS and absence of DS1
LOS.
365-372-300
Issue 8.0 September 2006
B - 5
Introduction to Performance Monitoring
B - 6
: Performance Monitoring
DS3 ports
Performance monitoring is enabled/disabled on a DS3 port basis using the Primary State (PST) parameter of the
Configuration > Provision
Equipment
command.
When the PST parameter is provisioned as AUTO and a valid signal
(non DS3 LOS) is detected, the PST parameter automatically transitions to the IS (in service) state. This initializes the data registers and enables DS3 line and path performance monitoring on the port.
When the PST parameter is provisioned as NMON or AUTO (with no valid input signal detected), DS3 line and path performance monitoring is disabled on the port.
E1 ports
Performance monitoring is enabled/disabled on a E1 port basis using the Primary State (PST) parameter of the
Configuration > Provision
Equipment
command.
When the PST parameter is provisioned as AUTO and a valid signal
(non E1 LOS) is detected, the PST parameter automatically transitions to the IS (in service) state. This initializes the data registers and enables
E1 line and path performance monitoring on the port.
When the PST parameter is provisioned as NMON or AUTO (with no valid input signal detected), E1 line and path performance monitoring is disabled on the port.
EC-1 ports
Performance monitoring is enabled/disabled on a EC-1 port basis using the Primary State (PST) parameter of the
Configuration > Provision
Equipment
command.
When the PST parameter is provisioned as AUTO and a valid signal
(non LOS) is detected, the PST parameter automatically transitions to the IS (in service) state. This initializes the data registers and enables
EC-1 line performance monitoring on the port.
When the PST parameter is provisioned as NMON or AUTO (with no valid input signal detected), EC-1 line performance monitoring is disabled on the port.
STS-n paths
Performance monitoring is enabled/disabled on terminated STS-n paths using the Primary State (PST) parameter of the
Configuration >
Provision Equipment
command.
365-372-300
Issue 8.0 September 2006
Introduction to Performance Monitoring
: Performance Monitoring
When the PST parameter is provisioned as AUTO and a valid signal
(non LOP-P, SF, UNEQ-P, or AIS-P) is detected, the PST parameter automatically transitions to the IS (in service) state. This initializes the data registers and enables terminated STS-n path performance monitoring.
When the PST parameter is provisioned as NMON or AUTO (with no valid input signal detected), terminated STS-n path performance monitoring is disabled.
Intermediate STS-n path performance monitoring is always enabled on pass through cross-connections.
VT1.5 paths
Performance monitoring is enabled/disabled on terminated VT1.5 paths using the Primary State (PST) parameter of the
Configuration >
Provision Equipment
command.
When the PST parameter is provisioned as AUTO and a valid signal
(non AIS-V, LOP-V, UNEQ-V) is detected, the PST parameter automatically transitions to the IS (in service) state. This initializes the data registers and enables terminated VT1.5 path performance monitoring.
When the PST parameter is provisioned as NMON or AUTO (with no valid input signal detected), terminated VT1.5 path performance monitoring is disabled.
VC-12 paths
Performance monitoring is enabled/disabled on terminated VC-12 paths using the Primary State (PST) parameter of the
Configuration >
Provision Equipment
command.
When the PST parameter is provisioned as AUTO and a valid signal
(non AIS-V, LOP-V, UNEQ-V) is detected, the PST parameter automatically transitions to the IS (in service) state. This initializes the data registers and enables terminated VC-12 path performance monitoring.
When the PST parameter is provisioned as NMON or AUTO (with no valid input signal detected), terminated VC-12 path performance monitoring is disabled.
365-372-300
Issue 8.0 September 2006
B - 7
Introduction to Performance Monitoring
: Performance Monitoring
Low Speed OC-n lines
Performance monitoring is enabled/disabled on low speed OC-n lines using the Primary State (PST) parameter of the
Configuration >
Provision Equipment
command.
When the PST parameter is provisioned as AUTO and a valid signal
(non LOS) is detected, the PST parameter automatically transitions to the IS (in service) state. This initializes the data registers and enables
OC-n section and line performance monitoring.
When the PST parameter is provisioned as NMON or AUTO (with no valid input signal detected), OC-n section and line performance monitoring is disabled.
For more information about the
Configuration > Provision Equipment
command, refer to the WaveStar
®
CIT on-line help.
High Speed OC-n lines
Performance monitoring is always enabled on high speed OC-n lines when a circuit pack is installed and a valid (non LOS) signal detected.
B - 8
365-372-300
Issue 8.0 September 2006
Introduction to Performance Monitoring
: Performance Monitoring
PM during failed conditions
When a trouble condition is detected, DMX stops accumulating PM parameters affected by that failure. PM parameters are inhibited during unavailable time per GR-253-CORE. All unaffected performance parameters continue to accumulate during a trouble condition.
The following performance parameters are not inhibited during unavailable time.
• Severely Errored Frame Seconds (SEFS)
• Unavailable Seconds (UAS)
• Failure Counts (FC)
• Protection Switch Counts (PSC)
• Protection Switch Duration (PSD)
PM during loopbacks
When a loopback is established, DMX disables PM data collection on the associated line or path for the duration of the loopback. Any attempt to retrieve PM data on the looped back line or path is denied. When the loopback is removed, DMX initializes the data registers and restarts
PM data collection on the line or path.
PM during transmission tests
PM on extra traffic and nonpreemptible unprotected traffic (NUT)
Threshold crossing alerts
(TCAs)
When a transmission test is executed, DMX disables PM data collection on the associated port for the duration of the transmission test. Any attempt to retrieve PM data on the port is denied. When the transmission test completes, DMX initializes the data registers and restarts PM data collection on the port.
DMX supports performance monitoring on nonpreemptible unprotected traffic (NUT).
When the value of a current quarter-hour or the current day register meets or exceeds the corresponding provisioned threshold, DMX generates a threshold-crossing alert (TCA) that is entered into the performance monitoring exception report and reported to the OS through the TL1 interface.
In order to view autonomous TCAs, Event Messaging must be enabled.
365-372-300
Issue 8.0 September 2006
B - 9
Introduction to Performance Monitoring
: Performance Monitoring
Enabling/disabling TCA reporting
TL1 access
The TL1 interfaces should be used to derive full benefit from DMX’s performance monitoring capabilities. The full set of PM data stored by
DMX (TCAs and the contents of PM registers) is provided through the
TL1 interface.
TCA reporting can be enabled/disabled for DS1 ports, DS3 ports, E1 ports, EC-1 ports, STS-n paths, VT1.5 paths, VC-12 paths, and OC-N lines.
In order to disable TCAs set the threshold to zero or use the TCAMD parameter.
B - 1 0
DS1 ports
TCA reporting is available when a DS1 or TMUX circuit pack is installed, a valid signal is detected, and a cross-connection is established. TCA reporting is enabled/disabled on a DS1 port basis using the TCA Mode (TCAMD) parameter of the
Configuration >
Provision Equipment
command.
When the TCAMD parameter is provisioned as ENABLE, TCAs are reported for the DS1 line and path.
When the TCAMD parameter is provisioned as DISABLE, TCAs are not reported for the DS1 line and path.
The port primary state (PST) parameter must be IS (in service) for TCA reporting. If the port PST parameter is NMON or AUTO, performance monitoring and TCA reporting are disabled.
DS3 ports
DS3 line TCA reporting is available when a DS3 circuit pack is installed. DS3 path TCA reporting is available when a DS3 circuit pack is installed, a valid signal is detected, and a cross-connection is established. TCA reporting is enabled/disabled on a DS3 port basis using the TCA Mode (TCAMD) parameter of the
Configuration >
Provision Equipment
command.
When the TCAMD parameter is provisioned as ENABLE, TCAs are reported for the DS3 line and path.
When the TCAMD parameter is provisioned as DISABLE, TCAs are not reported for the DS3 line and path.
The port primary state (PST) parameter must be IS (in service) for TCA reporting. If the port PST parameter is NMON or AUTO, performance monitoring and TCA reporting are disabled.
365-372-300
Issue 8.0 September 2006
Introduction to Performance Monitoring
365-372-300
Issue 8.0 September 2006
: Performance Monitoring
E1 ports
TCA reporting is available when a E1 circuit pack is installed, a valid signal is detected, and a cross-connection is established. TCA reporting is enabled/disabled on a E1 port basis using the TCA Mode (TCAMD) parameter of the
Configuration > Provision Equipment
command.
When the TCAMD parameter is provisioned as ENABLE, TCAs are reported for the E1 line and path.
When the TCAMD parameter is provisioned as DISABLE, TCAs are not reported for the E1 line and path.
The port primary state (PST) parameter must be IS (in service) for TCA reporting. If the port PST parameter is NMON or AUTO, performance monitoring and TCA reporting are disabled.
EC-1 ports
EC-1 line TCA reporting is available when a circuit pack is installed.
TCA reporting is enabled/disabled on an EC-1 port basis using the
TCA Mode (TCAMD) parameter of the
Configuration > Provision
Equipment
command.
When the TCAMD parameter is provisioned as ENABLE, TCAs are reported for the EC-1 line.
When the TCAMD parameter is provisioned as DISABLE, TCAs are not reported for the EC-1 line.
The port primary state (PST) parameter must be IS (in service) for TCA reporting. If the PST parameter is NMON or AUTO, performance monitoring and TCA reporting are disabled.
STS-n paths
STS-n terminated and intermediate path TCA reporting is available when an STS-n cross-connection is established. TCA reporting is enabled/disabled on an STS-n path basis using the TCA Mode
(TCAMD) parameter of the
Configuration > Provision Equipment
command.
When the TCAMD parameter is provisioned as ENABLE, TCAs are reported for the STS-n terminated and intermediate path.
When the TCAMD parameter is provisioned as DISABLE, TCAs are not reported for the STS-n terminated and intermediate path.
The STS-n terminated path primary state (PST) parameter must be IS
(in service) for TCA reporting. If the PST parameter is NMON or
AUTO, performance monitoring and TCA reporting of the STS-n
B - 1 1
Introduction to Performance Monitoring
: Performance Monitoring
terminated path are disabled. (The PST parameter does not affect performance monitoring on STS-n intermediate paths.)
VT1.5 paths
VT1.5 terminated path TCA reporting is available when an STS/VT cross-connection is established. TCA reporting is enabled/disabled on a path basis using the TCA Mode (TCAMD) parameter of the
Configuration > Provision Equipment
command.
When the TCAMD parameter is provisioned as ENABLE, TCAs are reported for the VT1.5 terminated path.
When the TCAMD parameter is provisioned as DISABLE, TCAs are not reported for the VT1.5 terminated path.
The VT1.5 terminated path primary state (PST) parameter must be IS
(in service) for TCA reporting. If the PST parameter is NMON or
AUTO, performance monitoring and TCA reporting are disabled.
If/when an STS path is set to NMON, the constituent VT1.5 paths will also be set to NMON. The customer may then change the VT1.5 path primary state to AUTO in order to continue reporting TCAs.
VC-12 paths
VC-12 terminated path TCA reporting is available when an STS/VC cross-connection is established. TCA reporting is enabled/disabled on a path basis using the TCA Mode (TCAMD) parameter of the
Configuration > Provision Equipment
command.
When the TCAMD parameter is provisioned as ENABLE, TCAs are reported for the VC-12 terminated path.
When the TCAMD parameter is provisioned as DISABLE, TCAs are not reported for the VC-12 terminated path.
The VC-12 terminated path primary state (PST) parameter must be IS
(in service) for TCA reporting. If the PST parameter is NMON or
AUTO, performance monitoring and TCA reporting are disabled.
If/when an STS path is set to NMON, the constituent VC-12 paths will also be set to NMON. The customer may then change the VC-12 path primary state to AUTO in order to continue reporting TCAs.
B - 1 2
365-372-300
Issue 8.0 September 2006
Introduction to Performance Monitoring
: Performance Monitoring
OC-n lines
OC-n section and line TCA reporting is available when a circuit pack is installed. TCA reporting is enabled/disabled on an OC-n line basis using the TCA Mode (TCAMD) parameter of the
Configuration >
Provision Equipment
command.
When the TCAMD parameter is provisioned as ENABLE, TCAs are reported for the OC-n section and line.
When the TCAMD parameter is provisioned as DISABLE, TCAs are not reported for the OC-n section and line.
The line primary state (PST) parameter must be IS (in service) for TCA reporting of a low speed OC-n section or line. If the PST parameter of a low speed OC-n line is NMON or AUTO, performance monitoring and
TCA reporting are disabled. (The PST parameter of high speed OC-n lines is not user provisionable.)
Provisioning TCA parameter thresholds
Retrieving TCAs
The current quarter-hour and current day thresholds for each parameter type are provisionable, on a per-shelf basis. If values other than the defaults are used, only one value for each parameter type needs to be set for each signal.
Provisioning an individual performance monitoring parameter threshold to zero (0) disables reporting the TCAs for that parameter.
For more information about provision performance monitoring thresholds refer to the WaveStar
®
CIT on-line help and the DMX User
Operations Guide (UOG).
All TCAs are retrievable either locally or remotely via the WaveStar
®
CIT. If provisioned for autonomous TCA reporting, the message-based operations system interface can communicate TCA reports to the operations centers.
365-372-300
Issue 8.0 September 2006
B - 1 3
: Performance Monitoring
OC-N Performance Parameters
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Overview
This section describes the performance monitoring parameters that are applicable to SONET OC-N signals.
Monitored parameters
The following table lists the SONET OC-N section and line performance parameters that DMX monitors, including the default and ranges for the 15-minute and 1-day (24-hour) registers.
Table B-2 SONET OC-N Performance Parameters
Facility
OC-N Section
OC-192 Section
OC-48 Section
OC-12 Section
OC-3 Section
OC-192 Line
OC-48 Line
OC-12 Line
OC-3 Line
15-Min
Measured Provisionable Parameter
Default
Range
(Note)
Section Errored Seconds (ESS)
SE Frame Seconds (SEFS/SEFS-S)
30
10
0-900
0-900
90
30
1-Day
Default
Range
(Note)
0-65535
0-65535
Severely Errored Seconds (SESS/LESS-S) 30
Coding Violations (CV-L) 8960
0-900
0-16383
90
86016
0-65535
0-1048575
Coding Violations (CV-L)
Coding Violations (CV-L)
Coding Violations (CV-L)
Coding Violations (CV-L), CV-L FE
2240
560
140
0-16383
0-16383
21504
5376
0-1048575
0-1048575
0-16383 1344 0-1048575
8960 0-16383 86016 0-1048575
Coding Violations (CV-L), CV-L FE
Coding Violations (CV-L), CV-L FE
Coding Violations (CV-L), CV-L FE
2240 0-16383 21504 0-1048575
560 0-16383 5376 0-1048575
140 0-16383 1344 0-1048575
B - 1 4
365-372-300
Issue 8.0 September 2006
OC-N Performance Parameters
: Performance Monitoring
Facility
OC-N Line
15-Min
Measured Provisionable Parameter
Default
Range
(Note)
Errored Seconds (ES-L)
Errored Seconds Far End (ES-L FE)
Far-End Line Failure Counts (FC-L)
Far-End Line Failure Counts Far End
(FC-L FE)
40
10
0-900
1-72
Severely Errored Seconds (SES-L)
Severely Errored Seconds Far End (SES-L
FE)
Unavailable Seconds (UAS-L)
Unavailable Seconds Far-End (UAS-L FE)
Protection Switch Count Line (PSC-L)
Protection Switch Count Protection
(PSC-P) (BLSR only)
Protection Switch Count Working
(PSC-W) (BLSR only)
Protection Switch Duration (PSC-D)
(BLSR Only)
30
30
2
2
2
0-900
0-900
0-63
0-63
0-63
NA
1-Day
Default
Range
(Note)
900
10
90
90
4
4
4
0-65535
1-4095
0-65535
0-65535
0-255
0-255
0-255
Pointer Justification Count Difference
(PJCDIFF-P)
Negative Pointer Justification Count
Detected (NPJC-PDET)
Positive Pointer Justification Count
Detected (PPJC-PDET)
Negative Pointer Justification Count
Generated (NPJC-PGEN)
60
60
60
60
0-1048575
0-1048575
0-1048575
0-1048575
5760
5760
5760
5760
0-16777215
0-16777215
0-16777215
0-16777215
Positive Pointer Justification Count
Generated (PPJC-PGEN)
60 0-1048575 5760 0-16777215
Note: When an individual performance monitoring parameter threshold is provisioned as zero (0), TCA reporting for the affected parameter is disabled.
OC-N section parameter
DMX monitors the following near end SONET section parameters for incoming (from the lightguide cross-connect) OC-N signals. The parameters are measured at the input of the OC-N OLIU circuit pack on the line side (also referred to as LGX side).
365-372-300
Issue 8.0 September 2006
B - 1 5
OC-N Performance Parameters
: Performance Monitoring
Coding violations (CV-S)
The Section Coding Violations (CV-S) parameter for each SONET section is monitored. The CV-S parameter is a count of BIP errors at the Section Layer (i.e., B1 errors). Up to eight Section BIP errors can be detected per STS-N frame, with each error incrementing the CV-S current second register.
Errored seconds (ES-S)
The Section Errored Seconds (ESS) parameter for each SONET section is monitored. The ESS parameter increments once for each second in which at least one Section Layer BIP error was detected or an SEF or
LOS defect was present.
Severely errored frame seconds (SEFS/SEFS-S)
The SEFS/SEFS-S parameter increments once for each second during which DMX detects one or more near end severely errored frame defects.
OC-N Section PM Report
Use the
Performance > Reports > OCn Section
command to obtain the
OC-N Section PM Report. For more information about the OC-N section parameter and the
Performance > Reports > OCn Section
command, refer to the WaveStar
®
CIT on-line help.
OC-N line parameters
DMX monitors the following near end SONET line parameters for incoming (from the lightguide cross-connect) OC-N signals. The parameters are measured at the input of the OC-N OLIU circuit pack on the OC-N line side (also referred to as LGX side).
Coding violations (CV-L)
The Near-End Line Coding Violation (CVL) parameter for each
SONET Line is monitored. The Near-End CVL parameter increments once for every occurrence of a BIP error detected at the Line layer (i.e. using the B2 byte in the incoming SONET signal). Up to 8*N BIP errors can be detected per STS-N frame.
Errored seconds (ES-L)
The Near-End Line Errored Seconds (ESL) parameter for each SONET
Line is monitored. The Near-End CVL parameter increments once for every second that contains at least one BIP error detected at the Line layer (at any point during the second), or an AIS-L defect was present.
B - 1 6
365-372-300
Issue 8.0 September 2006
OC-N Performance Parameters
365-372-300
Issue 8.0 September 2006
: Performance Monitoring
Severely errored seconds (SES-L)
The Near-End Line Severely Errored Seconds (SESL) parameter for each SONET Line is monitored. The Near-End SESL parameter increments once for every second that contains at least K BIP errors detected at the Line layer (at any point during the second), or an AIS-L defect was present. The value of K is hard-coded, see table 7 for a list of the values
Unavailable seconds (UAS-L)
The Near-End Line Unavailable Seconds (UASL) parameter for each
SONET Line is monitored. The Near-End UASL parameter increments once for every second that the Line was considered unavailable (at any point during the second). A Line becomes unavailable at the onset of 10 consecutive seconds that qualify as Near-End SESLs, and continues to be unavailable until the onset of 10 consecutive seconds that do not qualify as Near-End SESLs.
Far-End Line Failure Counts (FC-L)
The Far-End Line Failure Counts (FC-L) parameter for each SONET line is monitored. The Far-End FC-L parameter increments once for the beginning of each RFI-L event (RFI-L detected and cleared). A failure that begins in one period and ends in another period, is counted in the period in which it begins.
Protection switch count (PSC-L)
The PSC parameter records the number of times that service traffic switched to or from another line either automatically, by a WaveStar
®
CIT command, or operations system command. The Near-End
Protection Switch Counts (PSC-L) parameter for each SONET line
(that supports 1+1 protection switching for that line) is monitored.
Separate PSC counters is provided for differentiating between working and protection for each SONET line that supports 2F BLSR for that line. n a 2 Fiber ring, two separate PSC counts are maintained for the working and protection fibers in a given line. These parameters will be defined as PSC-W and PSC-P for Protection Switch Counts-Working and Protection Switch Counts-Protection respectively.
Pointer justifications counts difference (PJCDIFF-P)
This is a calculation of the absolute value of the PJC parameters listed under the headings below.
PJCDIFF-P is used to calculate the difference between calculate the difference between the PPJC-PGEN,
NPJC-PGEN and between PPJC-PDET and NPJC-PDET. DMX monitors the first cross-connected STS. From this STS, the calculation
B - 1 7
OC-N Performance Parameters
B - 1 8
: Performance Monitoring
is to (A) calculate the difference between the PPJC-PGEN,
NPJC-PGEN. (B) Calculate the difference of the PPJC-PDET,
NPJC-PDET. The resulting PJC is the absolute value of the difference between A and B.
Negative pointer justifications counts detected (NPJC-PDET)
This parameter summarizes all Negative Pointer Justifications detected by the system
.
DMX monitors negative line Pointer Justifications on an
STS-1 within the OC-n line in 1 second intervals. (Users may select which STS-1 to monitor by provisioning the PJC Monitoring point parameter using the
Performance > Provision PM
command.) The count increments for each incoming negative STS pointer justification.
Positive pointer justifications counts detected (PPJC-PDET)
This parameter summarizes all Positive Pointer Justifications detected by the system.
DMX monitors positive line Pointer Justifications on an
STS-1 within the OC-n line in 1 second intervals. (Users may select which STS-1 to monitor by provisioning the PJC Monitoring point parameter using the
Performance > Provision PM
command.) The count increments for each incoming positive STS pointer justification.
Negative pointer justifications counts generated (NPJC-PGEN)
This parameter summarizes all Negative Pointer Justifications generated by the system.
DMX monitors negative line Pointer
Justifications on an STS-1 within the OC-n line in 1 second intervals.
(Users may select which STS-1 to monitor by provisioning the PJC
Monitoring point parameter using the
Performance > Provision PM
command.) The count increments for each outgoing negative STS pointer justification.
Positive pointer justifications counts generated (PPJC-PGEN)
This parameter summarizes all Positive Pointer Justifications generated by the system.
DMX monitors positive line Pointer Justifications on an
STS-1 within the OC-n line in 1 second intervals. (Users may select which STS-1 to monitor by provisioning the PJC Monitoring point parameter using the
Performance > Provision PM
command.) The count increments for each outgoing positive STS pointer justification.
OC-N Line PM Report
Use the
Performance > Reports > OCn Line
command to obtain the OC-N
Line PM Report. For more information about the OC-N line parameters
365-372-300
Issue 8.0 September 2006
OC-N Performance Parameters
: Performance Monitoring
and the
Performance > Reports > OCn Line
command, refer to the
WaveStar
®
CIT on-line help.
365-372-300
Issue 8.0 September 2006
B - 1 9
: Performance Monitoring
EC-1 Performance Parameters
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Overview
This section describes the performance monitoring parameters that are applicable to SONET EC-1 signals.
Monitored parameters
The following table lists the SONET EC-1 line performance parameters that DMX monitors, including the default and ranges for the
15-minute and 1-day (24-hour) registers.
Table B-3 SONET EC-1 Performance Parameters
Facility
EC-1 Line
Measured Provisionable Parameter
Coding Violations (CV-L), CV-LFE
Errored Seconds (ES-L), ES-LFE
Severely Errored Seconds (SES-L),
SES-LFE
Unavailable Seconds (UAS-L), UAS-LFE
Far-End Line Failure Counts (FC-L)
Far-End Line Failure Counts Far End (FC-L
FE)
Pointer Justification Count Difference
(PJCDIFF-P)
15-Min
Default
Range
(Note)
47
40
0-16383
0-900
30
30
10
60
0-900
0-900
1-72
0-900
Default
448
900
90
90
10
5760
1-Day
Range
(Note)
0-1048575
0-65535
0-65535
0-65535
1-4095
0-65535
Negative Pointer Justification Count
Detected (NPJC-PDET)
Positive Pointer Justification Count
Detected (PPJC-PDET)
Negative Pointer Justification Count
Generated (NPJC-PGEN)
Positive Pointer Justification Count
Generated (PPJC-PGEN)
60
60
60
60
0-900
0-900
0-900
0-900
5760
5760
5760
5760
0-65535
0-65535
0-65535
0-65535
Note: When an individual performance monitoring parameter threshold is provisioned as zero (0), TCA reporting for the affected parameter is disabled.
B - 2 0
365-372-300
Issue 8.0 September 2006
EC-1 Performance Parameters
: Performance Monitoring
EC-1 line parameters
DMX monitors the following near end SONET line parameters on incoming (from the local cross-connect) EC-1 signals. The parameters are measured at the input of the 12DS3/EC1 circuit pack on the EC-1 line side (also referred to as facility, customer terminal, or STSX-1 side).
Coding violations (CV-L)
The Near-End Line Coding Violation (CVL) parameter for each
SONET Line is monitored. The Near-End CVL parameter increments once for every occurrence of a BIP error detected at the Line layer (i.e. using the B2 byte in the incoming SONET signal). Up to 8*N BIP errors can be detected per STS-N frame.
Errored seconds (ES-L)
The Near-End Line Errored Seconds (ESL) parameter for each SONET
Line is monitored. The Near-End CVL parameter increments once for every second that contains at least one BIP error detected at the Line layer (at any point during the second), or an AIS-L defect was present.
Severely errored seconds (SES-L)
The Near-End Line Severely Errored Seconds (SESL) parameter for each SONET Line is monitored. The Near-End SESL parameter increments once for every second that contains at least K BIP errors detected at the Line layer (at any point during the second), or an AIS-L defect was present. The value of K is hard-coded, see table 7 for a list of the values
Unavailable seconds (UAS-L)
The Near-End Line Unavailable Seconds (UASL) parameter for each
SONET Line is monitored. The Near-End UASL parameter increments once for every second that the Line was considered unavailable (at any point during the second). A Line becomes unavailable at the onset of 10 consecutive seconds that qualify as Near-End SESLs, and continues to be unavailable until the onset of 10 consecutive seconds that do not qualify as Near-End SESLs.
Far-End Line Failure Counts (FC-L)
The Far-End Line Failure Counts (FC-L) parameter for each SONET line is monitored. The Far-End FC-L parameter increments once for the beginning of each RFI-L event (RFI-L detected and cleared). A failure that begins in one period and ends in another period, is counted in the period in which it begins.
365-372-300
Issue 8.0 September 2006
B - 2 1
EC-1 Performance Parameters
B - 2 2
: Performance Monitoring
Pointer justifications counts difference (PJCDIFF-P)
This is a calculation of the absolute value of the PJC parameters listed under the headings below.
PJCDIFF-P is used to calculate the difference between calculate the difference between the PPJC-PGEN,
NPJC-PGEN and between PPJC-PDET and NPJC-PDET. DMX monitors the first cross-connected STS. From this STS, the calculation is to (A) calculate the difference between the PPJC-PGEN,
NPJC-PGEN. (B) Calculate the difference of the PPJC-PDET,
NPJC-PDET. The resulting PJC is the absolute value of the difference between A and B.
Negative pointer justifications counts detected (NPJC-PDET)
This parameter summarizes all Negative Pointer Justifications detected by the system
.
DMX monitors negative line Pointer Justifications on an
STS-1 within the OC-n line in 1 second intervals. (Users may select which STS-1 to monitor by provisioning the PJC Monitoring point parameter using the
Performance > Provision PM
command.) The count increments for each incoming negative STS pointer justification.
Positive pointer justifications counts detected (PPJC-PDET)
This parameter summarizes all Positive Pointer Justifications detected by the system.
DMX monitors positive line Pointer Justifications on an
STS-1 within the OC-n line in 1 second intervals. (Users may select which STS-1 to monitor by provisioning the PJC Monitoring point parameter using the
Performance > Provision PM
command.) The count increments for each incoming positive STS pointer justification.
Negative pointer justifications counts generated (NPJC-PGEN)
This parameter summarizes all Negative Pointer Justifications generated by the system.
DMX monitors negative line Pointer
Justifications on an STS-1 within the OC-n line in 1 second intervals.
(Users may select which STS-1 to monitor by provisioning the PJC
Monitoring point parameter using the
Performance > Provision PM
command.) The count increments for each outgoing negative STS pointer justification.
Positive pointer justifications counts generated (PPJC-PGEN)
This parameter summarizes all Positive Pointer Justifications generated by the system.
DMX monitors positive line Pointer Justifications on an
STS-1 within the OC-n line in 1 second intervals. (Users may select which STS-1 to monitor by provisioning the PJC Monitoring point
365-372-300
Issue 8.0 September 2006
EC-1 Performance Parameters
: Performance Monitoring
parameter using the
Performance > Provision PM
command.) The count increments for each outgoing positive STS pointer justification.
EC-1 Line PM Report
Use the
Performance > Reports > EC1 Line
command to obtain the EC-1
Line PM Report. For more information about the EC-1 line parameters and the
Performance > Reports > EC1 Line
command, refer to the
WaveStar
®
CIT on-line help.
365-372-300
Issue 8.0 September 2006
B - 2 3
: Performance Monitoring
E1 Performance Parameters
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Overview
This section describes the performance monitoring parameters that are applicable to E1 signals.
Monitored parameters
The following table lists the E1 line performance parameters that DMX monitors, including the default and ranges for the 15-minute and 1-day
(24-hour) registers.
Table B-4 SONET E1 Performance Parameters
Facility
E1 Line
Measured Provisionable Parameter
Errored Seconds (ES-L)
Severely Errored Seconds (SES-L)
15-Min
Default
Range
(Note)
65
10
0-900
0-900
Default
648
100
1-Day
Range
(Note)
0-65535
0-65535
Background Block Errors - Path
(BBE-P),
BBE-PFE
Errored Seconds (ES-P), ES-PFE
13290 0-16383 3865 0-1048575
E1 Path
Severely Errored Seconds (SES-P),
SES-PFE
Unavailable Seconds (UAS-P), UAS-PFE
65
10
0-900
0-900
648
100
0-65535
0-65535
10 0-900 10 0-65535
Note: When an individual performance monitoring parameter threshold is provisioned as zero (0), TCA reporting for the affected parameter is disabled.
B - 2 4
365-372-300
Issue 8.0 September 2006
EC-1 Performance Parameters
: Performance Monitoring
E1 line parameters
DMX monitors the following near end SONET line parameters on incoming (from the local cross-connect) E1 signals. The parameters are measured at the input of the DS1/E1 circuit pack on the E1 line side
(also referred to as facility, customer terminal, or STSX-1 side).
Errored seconds (ES-L)
The Near-End Line Errored Seconds (ESL) parameter for each SONET
Line is monitored. The Near-End CVL parameter increments once for every second that contains at least one BIP error detected at the Line layer (at any point during the second), or an AIS-L defect was present.
The Far-End Line Errored Seconds parameter for each SONET line is monitored. The Far-End ESL parameter increments once for each second where one or more Far-End Line layer BIP errors are detected as reported by the REI-L indication of the line overhead or an RDI-L defect is detected.
Severely errored seconds (SES-L)
The Near-End Line Severely Errored Seconds (SESL) parameter for each SONET Line is monitored. The Near-End SESL parameter increments once for every second that contains at least K BIP errors detected at the Line layer (at any point during the second), or an AIS-L defect was present. The value of K is hard-coded, see table 7 for a list of the values.
The Far-End Line Severely Errored Seconds parameter for each
SONET line is monitored. The Far-End SESL parameter increments once for each second where K or more Line layer BIP errors are detected as reported by the REI-L indication of the line overhead or an
RDI-L defect is detected. The integer value for K is set by standards and is selectable
EC-1 Line PM Report
Use the
Performance > Reports > EC1 Line
command to obtain the EC-1
Line PM Report. For more information about the EC-1 line parameters and the
Performance > Reports > EC1 Line
command, refer to the
WaveStar
®
CIT on-line help.
E1 path parameters
DMX monitors the following near end path parameters on incoming
(from the local cross-connect) E1 signals. The parameters are measured at the input of the DS1/E1 circuit pack on the E1 line side (also referred to as facility, customer terminal, or STSX-1 side).
365-372-300
Issue 8.0 September 2006
B - 2 5
EC-1 Performance Parameters
B - 2 6
: Performance Monitoring
Background Block Errors (BBE-P)
The Near-End E1 Background Block Errors (BBE-P) parameter for each E1 Path is monitored. The number of Near-End BBE-Ps in a one second period is equal to the Near-End EBC if the second is not a
Near-End SES. Otherwise, the BBE-P is set to zero for that second.
The Far-End E1 Background Block Errors (BBE-P) parameter for each
E1 Path is monitored. The number of Far-End E1 BBE-Ps in a one second period is equal to the Far-End EBC if the second is not a Far-End
SESP and there is not a Near-End Defect. Otherwise, the BBE-P is set to zero for that second.
The BBE-P parameter applies only to the CRC-4 MultiFrame format.
Errored seconds (ES-P)
The Near-End E1 Path Errored Seconds (ESP) parameter for each E1 signal is monitored. The ESP parameter applies to both FAS format and
CRC-4 MultiFrame format.
For the FAS format, the ESP parameter increments once for each one second interval containing one or more errored FAS anomalies, or one or more defects.
For the CRC-4 MultiFrame format, the ESP parameter increments once for each one second interval containing CRC-4 block errors, or one or more defects.
The Far-End E1 Path Errored Seconds (ESP) parameter for each E1 path is monitored. The Far-End ESP parameter applies to both FAS format and CRC-4 MultiFrame format.
For the FAS format, the Far-End ESP parameter increments once for each one second interval containing one or more RDI defects and there is not a Near-End Defect.
For the CRC-4 MultiFrame format, the Far-End ES parameter increments once for each one second interval containing one or more RDI defects, or a Far-End Block Error (FEBE), and there is not a Near-End
Defect.
If the A-Bit equals 1 in four or more double frames, then there is an
RDI defect.
Severely errored seconds (SES-P)
The Near-End E1 Path Severely Errored Seconds (SESP) parameter for each E1 path is monitored. The SES parameter applies to both FAS frame and CRC-4 MultiFrame formats.
365-372-300
Issue 8.0 September 2006
EC-1 Performance Parameters
: Performance Monitoring
For the FAS format, the SES parameter increments once for each one second interval containing 28 or more frame bit errors, or one or more defects.
For the CRC-4 MultiFrame format, the SES parameter increments once for each one second interval containing 300 or more CRC-4 block errors, or one or more defects.
The Far-End E1 Path Severely Errored Seconds (SESP) parameter for each E1 path is monitored. The Far-End SESP parameter applies to both
FAS format and CRC-4 MultiFrame format.
For the FAS format, the Far-End SESP parameter increments once for each one second interval containing one or more RDI defects and there is not a Near-End Defect.
For the CRC-4 MultiFrame format, the Far-END ESP parameter increments once for each one second interval containing one or more
RDI defects, or 300 or more FEBEs and there is not a Near-End Defect.
If the A-Bit equals 1 in four or more double frames, then there is an RDI defect.
FEBE is based on the E-bit (ITU-T G.704).
Unavailable seconds (UAS-P)
The Near-End E1 Path UAS Seconds (UASP) parameter for each E1 path is monitored. The UAS parameter is a count of 1 second intervals for which the E1 path is unavailable at the onset of 10 contiguous SESs.
The 10 SESs are included in the unavailable time. Once unavailable, the UAS continues to increment once for each second until ten consecutive seconds without SES are detected. The 10 seconds without
SESs are excluded from the unavailable time. The UAS parameter applies to both FAS frame and CRC-4 MultiFrame formats.
The Far-End E1 Path UAS Seconds (UASP) parameter for each E1 path is monitored. The Far-End UASP parameter is a count of 1 second intervals for which the E1 path is unavailable at the onset of 10 contiguous SESs. The 10 SESs are included in the unavailable time.
Once unavailable, the Far-End UASP continues to increment once for each second until ten consecutive seconds without SES are detected.
The 10 seconds without SESs are excluded from the unavailable time.
The Far-End UASP parameter applies to both FAS frame and CRC-4
MultiFrame formats
.
365-372-300
Issue 8.0 September 2006
B - 2 7
: Performance Monitoring
STS-N Performance Parameters
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Overview
This section describes the performance monitoring parameters on terminated (STS-1) and intermediate STS-N (STS-1, STS-3c,
STS-12c) paths that are cross-connected through the system.
Intermediate SONET STS-N path performance monitoring applies to
STS-N paths cross-connected to another SONET interface. Terminated
SONET STS-N path performance monitoring applies to STS-N paths cross-connected to a non-SONET interface (for example, DS3).
Monitored parameters
The following table lists the SONET STS-N path performance parameters that DMX monitors, including the default and ranges for the
15-minute and 1-day (24-hour) registers.
Table B-5 SONET STS-N Performance Parameters
Facility Measured Provisionable Parameter
STS-48c Path Coding Violations (CV-P), CV-PFE
STS-12c Path Coding Violations (CV-P), CV-PFE
STS-3c Path Coding Violations (CV-P), CV-PFE
STS-1 Path Coding Violations (CV-P), CV-PFE
STS-48c Path Errored Seconds (ES-P), ES-PFE
STS-12c Path Errored Seconds (ES-P), ES-PFE
STS-3c Path Errored Seconds (ES-P), ES-PFE
STS-1 Path Errored Seconds (ES-P), ES-PFE
FC-P, FC-PFE
15
240
60
20
12
10
15-Min
Default
Range
(Note)
300
75
25
0-16383
0-16383
0-16383
0-900
0-16383
0-16383
0-16383
0-900
1-72
Default
3000
750
250
150
2400
600
200
100
10
1-Day
Range
(Note)
0-1048575
0-1048575
0-1048575
0-65535
0-1048575
0-1048575
0-1048575
0-65535
1-4095
STS-N Path
Severely Errored Seconds (SES-P),
SES-PFE
3 0-900 7 0-65535
Unavailable Seconds (UAS-P), UAS-PFE 10 0-900 10 0-65535
Note: When an individual performance monitoring parameter threshold is provisioned as zero (0), TCA reporting for the affected parameter is disabled.
B - 2 8
365-372-300
Issue 8.0 September 2006
STS-N Performance Parameters
: Performance Monitoring
STS-N path parameters
DMX monitors the following near end SONET STS path parameters on incoming (from the SONET interface) STS-N signals.
Coding violations (CV-P)
The Near-End STS Path Coding Violations (CVP) parameter for each
SONET path is monitored. The CVP parameter increments once for each BIP error detected at the STS path layer (the B3 byte of the incoming SONET STS Path overhead). Up to 8 BIP errors can be detected per frame.
The Far-End STS Path Coding Violations (CVP) parameter for each
SONET path is monitored. The Far-End CVP parameter increments as reported by the REI-P indication of the STS path overhead.
Errored seconds (ES-P)
The Near-End STS Path Errored Seconds (ESP) parameter for each
SONET path is monitored. The ESP parameter increments once for each second where one or more STS Path layer BIP errors are detected or an AIS-P, LOP-P, or UNEQ-P defect is detected.
The Far-End STS Path Errored Seconds (ESP) parameter for each
SONET path is monitored. The Far-End ESP parameter increments once for each second where one or more Far-End STS Path layer BIP errors are detected as reported by the REI-P indication of the line overhead or an RDI-P defect is present, or an ERDI-P (if supported) defect is detected.
Currently this product detects 1-bit RDI, but treats it as though it is the high order bit of a 3-bit ERDI in that it includes UNEQ.
365-372-300
Issue 8.0 September 2006
B - 2 9
STS-N Performance Parameters
: Performance Monitoring
Severely errored seconds (SES-P)
The Near-End STS Path Severely Errored Seconds (SESP) parameter for each SONET path is monitored. The SESP parameter increments once for each second where K or more STS Path layer BIP errors are detected or an AIS-P, LOP-P, or UNEQ-P defect is detected. The integer value for K is set by standards and is selectable (values are shown in Table 8). Currently DMXdetects 1-bit RDI, but treats it as though it is the high order bit of a 3-bit ERDI in that it includes UNEQ.
The Far-End STS Path Severely Errored Seconds (SESP) parameter for each SONET path is monitored. The Far-End SESP parameter increments once for each second where K or more STS Path layer BIP errors are detected as reported by the REI-P indication of the path overhead or a one bit RDI-P defect was present or (if ERDI-P is supported), an
ERDI-P defect is detected. The integer value for K is set by standards and selectable (values are shown in Table 8).
Currently this product detects 1-bit RDI, but treats it as though it is the high order bit of a 3-bit ERDI in that it includes UNEQ.
Unavailable seconds (UAS-P)
The Near-End STS Path Unavailable Seconds (UASP) parameter for each SONET path is monitored. The UASP parameter increments once for each second where SESP is detected after ten consecutive seconds with SESP detected. UASP continues to increment once for each second until ten consecutive seconds without SESP are detected.
The Far-End STS Path Unavailable Seconds (UASP) parameter for each SONET path is monitored. The Far-End UASP parameter increments once for each second where Far-End SESP is detected after ten consecutive seconds with Far-End SESP detected. Far-End UASP continues to increment once for each second until ten consecutive seconds without Far-End SESP are detected
.
B - 3 0
365-372-300
Issue 8.0 September 2006
STS-N Performance Parameters
: Performance Monitoring
Failure Counts Path (FC-P)
The Near-End STS Path Unavailable Seconds (UASP) parameter for each SONET path is monitored. The UASP parameter increments once for each second where SESP is detected after ten consecutive seconds with SESP detected. UASP continues to increment once for each second until ten consecutive seconds without SESP are detected.
The Far-End STS Path Failure Counts (FC-P) parameter for each
SONET path is monitored. The Far-End FC-P parameter increments once for the beginning of each RFI-P event (RFI-P detected and cleared). A failure that begins in one period and ends in another period, is counted in the period in which it begins.
STS-N Path PM Report
Use the
Performance > Reports > STSn Path
command to obtain the
STS-N Path PM Report. For more information about the STS-N path parameters and the
Performance > Reports > STSn Path
command, refer to the WaveStar
®
CIT on-line help.
365-372-300
Issue 8.0 September 2006
B - 3 1
: Performance Monitoring
VT1.5 Performance Parameters
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Overview
This section describes the terminated SONET VT1.5 performance monitoring parameters. Terminated SONET VT1.5 path performance monitoring applies to VT1.5 paths cross-connected to a non-SONET interface (for example, DS1 or TMUX).
Monitored parameters
The following table lists the SONET VT1.5 path performance parameters that DMX monitors, including the default and ranges for the
15-minute and 1-day (24-hour) registers.
Table B-6 SONET VT1.5 Performance Parameters
Facility
VT1.5 Path
Measured Provisionable Parameter
Coding Violations (CV-P), CV-PFE
V5 Errored Seconds (ES-P), ES-PFE
V5 Severely Errored Seconds (SES-P)
V5 Unavailable Seconds (UAS-P)
UAS-PFE
15-Min
Default
Range
(Note)
75
40
40
0-16383
0-900
0-900
40 0-900
Default
1-Day
Range
(Note)
750
900
900
0-1048575
0-65535
0-65535
900 0-65535
FC-P, FC-PFE 10 1-72 10 1-4095
Note: When an individual performance monitoring parameter threshold is provisioned as zero (0), TCA reporting for the affected parameter is disabled.
VT1.5 path parameters
DMX monitors the following near end SONET VT1.5 path parameters on incoming (from the SONET interface) VT1.5 signals.
Coding violations (CV-P)
The Near-End STS Path Coding Violations (CVP) parameter for each
SONET path is monitored. The CVP parameter increments once for each BIP error detected at the STS path layer (the B3 byte of the incoming SONET STS Path overhead). Up to 8 BIP errors can be detected per frame.
The Far-End VT Path Coding Violations (CVP) parameter for each
SONET path is monitored. The VT Far-End CVP parameter increments as reported by the REI-V indication of the VT path overhead.
B - 3 2
365-372-300
Issue 8.0 September 2006
VT1.5 Performance Parameters
: Performance Monitoring
Errored seconds (ES-P)
The Near-End STS Path Errored Seconds (ESP) parameter for each
SONET path is monitored. The ESP parameter increments once for each second where one or more STS Path layer BIP errors are detected or an AIS-P, LOP-P, or UNEQ-P defect is detected.
The Far-End VT Path Errored Seconds (ESP) parameter for each
SONET path is monitored. The VT Far-End ESP parameter increments once for each second where one or more Far-End VT Path layer BIP errors were reported by the far-end VT-PTE (using the REI-V indication), a one-bit RDI-V defect was present, or an ERDI-V (if supported) defect is detected.
Currently this product detects 1-bit RDI, but treats it as though it is the high order bit of a 3-bit ERDI in that it includes UNEQ.
Severely errored seconds (SES-P)
The Near-End STS Path Severely Errored Seconds (SESP) parameter for each SONET path is monitored. The SESP parameter increments once for each second where K or more STS Path layer BIP errors are detected or an AIS-P, LOP-P, or UNEQ-P defect is detected. The integer value for K is set by standards and is selectable (values are shown in Table 8). Currently DMXdetects 1-bit RDI, but treats it as though it is the high order bit of a 3-bit ERDI in that it includes UNEQ.
The Far-End VT Path Severely Errored Seconds (SESP) parameter for each SONET VT path is monitored. The VT Far-End SESP parameter increments once for each second where K or more BIP errors are reported by the far-end VT-PTE (using the REI-V indication), or a one bit RDI-V defect was present or (if ERDI-V is supported), an ERDI-V defect is detected. The integer value for K is set by standards (values are shown in Table 10).
Currently this product detects 1-bit RDI, but treats it as though it is the high order bit of a 3-bit ERDI in that it includes UNEQ.
365-372-300
Issue 8.0 September 2006
B - 3 3
VT1.5 Performance Parameters
: Performance Monitoring
Unavailable seconds (UAS-P)
The Near-End STS Path Unavailable Seconds (UASP) parameter for each SONET path is monitored. The UASP parameter increments once for each second where SESP is detected after ten consecutive seconds with SESP detected. UASP continues to increment once for each second until ten consecutive seconds without SESP are detected.
The Far-End VT Path Unavailable Seconds (UASP) parameter for each
SONET path is monitored. The VT Far-End UASP parameter increments once for each second where VT Far-End SESP is detected after ten consecutive seconds with VT Far-End SESP detected. VT
Far-End UASP continues to increment once for each second until ten consecutive seconds without VT Far-End SESP are detected.
Failure Counts Path (FC-P)
The Near-End STS Path Failure Counts (FC-P) parameter for each
SONET path is monitored. The FC-P parameter increments once for the beginning of each AIS-P event (AIS-P detected and cleared),
LOP-P event (LOP-P detected and cleared), UNEQ-P event (UNEQ-P detected and cleared). A failure that begins in one period and ends in another period, is counted in the period in which it begins.
The Far-End STS Path Failure Counts (FC-P) parameter for each
SONET path is monitored. The Far-End FC-P parameter increments once for the beginning of each RFI-P event (RFI-P detected and cleared). A failure that begins in one period and ends in another period, is counted in the period in which it begins
.
B - 3 4
365-372-300
Issue 8.0 September 2006
: Performance Monitoring
VC-12 Performance Parameters
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Overview
This section describes the terminated SONET VC-12 performance monitoring parameters. Terminated SONET VC-12 path performance monitoring applies to all VC-12 paths.
Monitored parameters
The following table lists the SONET VC-12 path performance parameters that DMX monitors, including the default and ranges for the
15-minute and 1-day (24-hour) registers.
Table B-7 SONET VC-12 Performance Parameters
Facility Measured Provisionable Parameter
15-Min
Default
Range
(Note)
Default
1-Day
Range
(Note)
VC-12 Path
Background Block Errors - Path
(BBE-P),
BB-PFE
Errored Seconds (ES-P), ES-PFE
Severely Errored Seconds (SES-P),
SES-PFE)
75
40
40
0-16383
0-900
0-900
750
900
900
0-1048575
0-65535
0-65535
Unavailable Seconds (UAS-P), UAS-PFE
FC-P, FC-PFE
40
10
0-900
1-72
900
10
0-65535
1-4095
Note: When an individual performance monitoring parameter threshold is provisioned as zero (0), TCA reporting for the affected parameter is disabled.
VC-12 path parameters Background Block Errors (BBE-P)
The Near-End E1 Background Block Errors (BBE-P) parameter for each E1 Path is monitored. The number of Near-End BBE-Ps in a one second period is equal to the Near-End EBC if the second is not a
Near-End SES. Otherwise, the BBE-P is set to zero for that second.
The Far-End Background Block Errors (BBE-P) parameter for each
Low Order Path is monitored. The number of Far-End VC-n BBE-Ps in a one second period is equal to the F_EBC if the second is not a Far-End
SES and if the second is not a N_DS. Otherwise, the Far-End BBE-P is set to zero for that second.
ITU-T standards refers to this parameter as F_BBE, but for consistency within the DMX product, this parameter will be referred to as BBE-P with a locn value of FEND to indicate that it is the Far-End Background
Block Errors.
365-372-300
Issue 8.0 September 2006
B - 3 5
VT1.5 Performance Parameters
: Performance Monitoring
Errored seconds (ES-P)
The Near-End VC-n Errored Seconds (ESP) parameter for each Low
Order VC-n is monitored. A Near-End VC-n ES parameter shall increment for each second in which there is one or more N_Bs (detected at the Low Order Path Layer) or a N_DS defect is present.
ITU-T standards refers to this parameter as N_ES, but for consistency within the DMX product, this parameter will be referred to as ES with a locn value of NEND to indicate that it is the Near-End Errored
Seconds.
The Far-End VC-n Errored Seconds (ESP) parameter for each Low
Order VC-n Path is monitored. A Far-End VC-n ES parameter shall increment for each second in which the Far-End errored block count
(F_EBC) is equal to or greater than 1 or when at least one F_DS defect is present for that second, and there is no N_DS present for that second.
ITU-T standards refers to this parameter as F_ES, but for consistency within the DMX product, this parameter will be referred to as ES with a locn value of FEND to indicate that it is the Far-End errored seconds.
Severely errored seconds (SES-P)
The Near-End VC-n Severely Errored Seconds (SESP) parameter for each Low Order VC-n is monitored. An Near-End VC-n SES parameter shall increment for each second in which the N_EBC is equal to or greater than K, or an N_DS defect is present. The integer value for K is set by standards (values are shown in Table 9). ITU-T standards refers to this parameter as N_SES, but for consistency within the DMX product, this parameter will be referred to as SES with a locn value of
NEND to indicate that it is the Near-End Severely Errored Seconds parameter.
The Far-End Severely Errored Seconds (SESP) parameter for each Low
Order VC-n Path is monitored. A Far-End VC-n SES parameter shall increment for each second in which the Far-End errored block count
(F_EBC) is equal to or greater than K or at least one F_DS defect is present for that second, and there is no N_DS defect present for that second. The integer value for K is set by standards (values are shown in
Table 9).
ITU-T standards refers to this parameter as F_SES, but for consistency within the DMX product, this parameter will be referred to as SES with a locn value of FEND to indicate that it is the Far-End Severely Errored
Seconds.
B - 3 6
365-372-300
Issue 8.0 September 2006
VT1.5 Performance Parameters
: Performance Monitoring
Unavailable seconds (UAS-P)
The Near-End VC-n Unavailable Seconds (UASP) parameter for each
Low Order Path is monitored. The Near-End VC-n UAS parameter increments once for every second that the Low Order Path was considered unavailable (at any point during the second). A Low Order Path becomes unavailable at the onset of 10 consecutive seconds that qualify as Near-End VC-n SESP, and continues to be unavailable until the onset of 10 consecutive seconds that do not qualify as Near-End VC-n
SES.
The (un)available time can not be determined if it is unknown whether the previous 10 seconds are Severely Errored on non-Severely Errored.
Thus the SES must be processed to determine whether the SES are consecutively present or absent. ITU-T standards refers to this parameter as N_UAS, but for consistency within the DMX product, this parameter will be referred to as UAS with a locn value of NEND to indicate that it is the Near-End Unavailable Seconds.
The Far-End Unavailable Seconds (UASP) parameter for each Low
Order Path is monitored. The Far-End VC-n UAS parameter increments once for every second that the Far-End Low Order Path was considered unavailable (at any point during the second). A Far-End Low Order Path becomes unavailable at the onset of 10 consecutive seconds that qualify as Far-End VC-n SESs, and continues to be unavailable until the onset of 10 consecutive seconds that do not qualify as Far-End VC-n SESs.
The (un)available time cannot be determined if it is unknown whether the previous 10 seconds are Severely Errored on non-Severely Errored.
Thus the Far-End VC-n SES must be processed to determine whether the Far-End VC-n SES are consecutively present or absent.
ITU-T standards refers to this parameter as F_UAS, but for consistency within the DMX product, this parameter will be referred to as UAS with a locn value of FEND to indicate that it is the Far-End Unavailable
Seconds.
365-372-300
Issue 8.0 September 2006
B - 3 7
VT1.5 Performance Parameters
: Performance Monitoring
Failure Counts Path (FC-P)
The Near-End VC-n Path Failure Counts (FC-P) parameter for each
Low Order path is monitored. The FC-P parameter increments once for the beginning of each TU-AIS event (TU-AIS detected and cleared),
TU-LOP event (TU-LOP detected and cleared), LP-UNEQ event
(LP-UNEQ detected and cleared), HP-LOM event (HP-LOM detected and cleared). A failure that begins in one period and ends in another period, is counted in the period in which it begins.
The Far-End VC-n Path Failure Counts (FC-P) parameter for each Low
Order path is monitored. The VC-n Far-End FC-P parameter increments once for the beginning of each RDI event (RDI detected and cleared). A failure that begins in one period and ends in another period, is counted in the period in which it begins.
B - 3 8
365-372-300
Issue 8.0 September 2006
: Performance Monitoring
DS3 Performance Monitoring Parameters
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Overview
This section describes the performance monitoring parameters that are monitored on DS3 signals incoming from the high speed fiber and from the local DSX-3 cross-connect.
In order to generate DS3 PM reports, the port Primary State must be
IS (in service). (When the PST parameter is provisioned as AUTO and a valid DS3 signal is detected, the PST parameter automatically transitions to the IS state.) The VM mode should be off because the
P-bits can be corrected at nodes where the VM Mode is provisioned on, and the DS3 P-bit PM data may not provide a complete report of the end-to-end DS3 path errors.
Monitored parameters
The following table lists the DS3 line and path performance parameters that DMX monitors, including the default and ranges for the 15-minute and 1-day (24-hour) registers.
Table B-8 DS3 Performance Parameters
Facility
DS3 Line
Measured Provisionable Parameter
Coding Violations (CV-L)
Errored Seconds (ES-L)
Severely Errored Seconds (SES-L)
Coding Violations (CV-P)
Coding Violations Far End (CV-PFE)
15-Min
Default
Range
(Note)
1-Day
Default
Range
(Note)
387 0-16383 3865 0-1048575
25 0-900 250 0-65535
4 0-900 40 0-65535
382 0-16383 3820 0-1048575
Errored Seconds (ES-P)
Errored Seconds Far End (ES-PFE)
Severely Errored Seconds (SES-P)
Severely Errored Seconds
Far End
(SES-PFE)
25 0-900 250 0-65535
4 0-900 40 0-65535
DS3 Path
Unavailable Seconds (UAS-P)
Unavailable Seconds Far End (UAS-PFE)
SE Frame/Alarm Indication Signal Seconds (SAS-P)
SE Frame/Alarm Indication Signal Seconds Far End
(SAS-PFE)
10
2
0-900
0-900
10
8
0-65535
0-65535
Note: When an individual performance monitoring parameter threshold is provisioned as zero (0), TCA reporting for the affected parameter is disabled.
365-372-300
Issue 8.0 September 2006
B - 3 9
DS3 Performance Monitoring Parameters
: Performance Monitoring
DS3 line parameters
DMX monitors the following ingress near end DS3 line parameters on incoming (from the DSX-3 cross-connect) DS3 signals. Ingress refers to performance monitoring parameters that are measured at the input of the DS3 or TMUX circuit pack on the DS3 line side (also referred to as facility, customer terminal, or DSX side).
Supported performance monitoring signal formats
DMX supports DS3 line performance monitoring on DS3 signals with
P-bit parity, FM-bit parity, or CP-bit parity performance monitoring signal formats.
Coding violations (CV-L)
The near end CV-L parameter increments once for each bipolar violation (BPV) and excessive zeros (EXZ) detected at the DS3 line layer.
Errored seconds (ES-L)
The near end ES-L parameter increments once for each second during which DMX detects either one or more bipolar violations (BPVs) or excessive zeros (EXZ), or one or more LOS defects.
Severely errored seconds (SES-L)
The near end SES-L parameter increments once for each second during which DMX detects either one or more LOS defects, 2444 or more
BPVs at a minimum BER of 7.5 X 10
-5
, or 45 or more BPVs at a minimum BER of 1 X 10
-6
.
DS3 Line PM Report
Use the
Performance > Reports > DS3 Line
command to obtain the DS3
Line PM Report. Ingress near end DS3 line PM is reported with an AID of the DS3 or TMUX interface and a modifier of T3. For more information about the DS3 line parameters and the
Performance >
Reports > DS3 Line
command, refer to the WaveStar
®
CIT on-line help.
B - 4 0
365-372-300
Issue 8.0 September 2006
DS3 Performance Monitoring Parameters
: Performance Monitoring
DS3 path performance monitoring signal format
DMX supports the following DS3 path performance monitoring signal formats:
• P-bit parity: The P bits are monitored for detecting code violations at the near end.
• FM-bit parity: The F and M bits are monitored for detecting code violations at the near end.
• CP-bit parity: CP-bit parity is used for end-to-end DS3 path PM
(near end and far end). The C bits are monitored for code violations. CP-bit parity is only allowed on DS3 signals with the
C-bit signal format.
P-bit parity
When provisioned for P-bit parity, DMX calculates and provides counts of the following near end DS3 path parameters incoming from the fiber or DSX-3:
• Coding violations (CV-P)
• Errored seconds (ES-P)
• Severely errored seconds (SES-P)
• Unavailable seconds (UAS-P)
• Severely errored frame/alarm indication signal seconds(SAS-P)
FM-bit parity
FM-bit parity provides an alternative method for determining and accumulating DS3 path performance data based on an error estimation technique using errors on the F&M framing bits to approximate the actual error counts in the DS3 path payload.
Adjusted F&M bit performance monitoring estimates the following near end DS3 path parameters incoming from the fiber or DSX-3:
• Coding violations (CV-P)
• Errored seconds (ES-P)
• Severely errored seconds (SES-P)
• Unavailable seconds (UAS-P)
• Severely errored frame/alarm indication signal seconds (SAS-P)
365-372-300
Issue 8.0 September 2006
B - 4 1
DS3 Performance Monitoring Parameters
: Performance Monitoring
CP-bit parity
When provisioned for CP-bit parity, DMX calculates and provides counts of the following DS3 near end and far end path parameters incoming from the fiber or DSX-3:
• Coding violations (CV-P)
• Coding violations Far End (CV-PFE)
• Errored seconds (ES-P)
• Errored seconds Far End (ES-PFE)
• Severely errored seconds (SES-P)
• Severely errored seconds Far End (SES-PFE)
• Unavailable seconds (UAS-P)
• Unavailable seconds Far End (UAS-PFE)
• Severely errored frame/alarm indication signal seconds (SAS-P)
• Severely errored frame/alarm indication signal seconds Far End
(SAS-PFE)
B - 4 2
365-372-300
Issue 8.0 September 2006
DS3 Performance Monitoring Parameters
: Performance Monitoring
Violation monitoring and removal
The DS3 path performance monitoring signal formats support provisionable P-bit monitoring and correction (violation monitoring mode) on the outgoing DS3 signal toward the DS3 facility.
The following table shows the provisionable DS3 signal formats, performance monitoring signal formats, and VM modes.
Table B-9 DS3 Signal formats, PM signal formats, and VM modes
DS3 Signal
Format
C-Bit
Performance
Monitoring
Signal
Format
VM Mode
P-bit parity
FM-bit parity
CP-bit parity
On
Off
On
Off
On
Off
X
X
Monitor
P-Bits
X
X
X
Correct
P-Bits
Near end DS3 path parameters
DMX monitors the following ingress and egress near end DS3 path parameters at the local network element. Ingress refers to parameters that are measured on incoming DS3 signals at the input of the local
DS3 or TMUX circuit pack on the DS3 line side (also referred to as facility, customer terminal, or DSX side). Egress refers to parameters that are measured on incoming DS3 signals at the input of the local
DS3 port unit on the SONET side (also referred to as fiber side).
Coding violations (CV-P)
The near end CV-P parameter increments once for each parity error detected at the path level. The CV-P parameter applies to all performance monitoring signal formats.
In the P-bit parity signal format, unidentical P-bits corresponding to the same DS3 M-frame also increment the CV-P parameter.
For CP-bit parity signal format, the three C-bits in subframe 3 of a
C-bit formatted DS3 frame carry the DS3 path-parity information. At the DS3 transmitter, the CP bits in the DS3 C-bit frame are set equal to the two P-bits in frame “n”. These CP bits are then inserted into frame
“n+1”. Since the CP bits are not modified in any way while passing
365-372-300
Issue 8.0 September 2006
B - 4 3
DS3 Performance Monitoring Parameters
: Performance Monitoring
through the network, the DS3 high-speed receiver can determine if errors occurred in the DS3 path. The DS3 receiver computes the parity of frame “n” and compares that parity with the value received in the CP bits in frame “n+1”. If the values do not match, DS3 path parity violations are counted.
Errored seconds (ES-P)
The near end ES-P parameter increments once for each second during which DMX detects either one or more parity errors, one or more SEF defects, or one or more AIS defects. The ES-P parameter applies to all performance monitoring signal formats.
Severely errored seconds (SES-P)
The near end SES-P parameter increments once for each second during which DMX detects either one or more AIS or SEF defects, 2444 or more BPVs at a minimum BER of 7.5 X 10
-5
, or 45 or more BPVs at a minimum BER of 1 X 10
-6
. The SES-P parameter applies to all performance monitoring signal formats.
Unavailable seconds (UAS-P)
A near end UAS-P is a second during which the path is unavailable. A path is considered unavailable from the beginning of 10 consecutive severely errored seconds until the beginning of 10 consecutive seconds, none of which are severely errored. The UAS-P parameter applies to the P-bit parity and FM-bit parity performance monitoring signal formats.
Severely errored frame/alarm indication signal seconds (SAS-P)
The SAS-P parameter increments once for each second during which
DMX detects either one or more severely errored frame defects, or one or more AIS defects. The SAS-P parameter applies to all performance monitoring signal formats.
B - 4 4
365-372-300
Issue 8.0 September 2006
DS3 Performance Monitoring Parameters
: Performance Monitoring
Near End DS3 Path PM Report
Use the
Performance > Reports > DS3 Path
command to obtain the DS3
Path PM Report. Ingress near end DS3 path PM is reported with an
AID of the DS3 or TMUX interface and a modifier of T3. Egress near end DS3 path PM is reported with an AID of the SONET interface and a modifier of T3. For more information about the DS3 path parameters and the
Performance > Reports > DS3 Path
command, refer to the
WaveStar
®
CIT on-line help.
Far end DS3 path parameters
DMX monitors the following ingress and egress far end DS3 path parameters at the local network element. If the far end network element detects an incoming error, the far end network element communicates the error back to the local near end network element using far end block error (FEBE) bits in the DS3 path overhead. (This allows the local near end DMX to perform the PM accumulation, storage, thresholding, and reporting functions for both the near end and far end.)
Ingress refers to far end parameters that are measured at the input of the local DS3 or TMUX circuit pack on the DS3 line side (also referred to as facility, customer terminal, or DSX side). Egress refers to far end parameters that are measured at the input of the local DS3 port unit on the SONET side (also referred to as fiber side).
Important!
The DS3 signal format must be provisioned for
C-Bit and the performance monitoring signal format must be provisioned for CP-Bit Parity to monitor the far-end parameters.
Coding violations Far End (CV-PFE)
The CV-PFE parameter increments as reported by the FEBE indication in the line overhead. At the far end if an incoming DS3 path error (for example, C-bit, F-bit, or M-bit error) is detected, an error indication is communicated back to the near end equipment by using the far end block error (FEBE) bits.
The FEBE message sent back from the far end is set to “111” if no path errors are detected. If a path error is detected, the FEBE message is set to “not 111." The FEBE monitor parameter (CV-PFE) increments once for each occurrence of a received “not all ones” pattern in the received
FEBE message.
365-372-300
Issue 8.0 September 2006
B - 4 5
DS3 Performance Monitoring Parameters
: Performance Monitoring
Errored seconds Far End (ES-PFE)
The ES-PFE parameter increments once for each second containing one or more M-frames with the three FEBE bits not all set to ONE or one or more far-end SEF or one or more far-end AIS defects.
Severely errored seconds Far End (SES-PFE)
The SES-PFE parameter increments once for each second where 2444 or more FEBE errors at a minimum BER of 7.5 X 10
-5
, or 45 or more
FEBE errors at a minimum BER of 1 X 10
-6
are detected as reported by the FEBE indication of the path overhead or one or more far-end SEF or one or more far-end AIS defects are detected.
Unavailable seconds Far End (UAS-PFE)
The UAS-PFE parameter is a count of 1 second intervals for which the
DS3 path is unavailable at the onset of 10 contiguous SES-PFEs. The
10 SES-PFEs are included in the unavailable time. Once unavailable, the UAS-PFE continues to increment once for each second until ten consecutive seconds without SES-PFE are detected. The 10 seconds without SES-PFEs are excluded from the unavailable time
.
Severely errored frame/alarm indication signal seconds Far End
(SAS-PFE)
The SAS-PFE parameter increments once for each second where one or more far end severely errored frame defects, or one or more far end AIS defects are detected
.
Far End DS3 Path PM Report
Use the
Performance > Reports > DS3 Path
command to obtain the DS3
Path PM Report. Ingress far end DS3 path PM is reported with an AID of the DS3 or TMUX interface and a modifier of T3. Egress far end
DS3 path PM is reported with an AID of the SONET interface and a modifier of T3. For more information about the DS3 path parameters and the
Performance > Reports > DS3 Path
command, refer to the
WaveStar
®
CIT on-line help.
B - 4 6
365-372-300
Issue 8.0 September 2006
: Performance Monitoring
DS1 Performance Monitoring Parameters
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Overview
This section describes the performance monitoring parameters relevant to DS1 signals incoming from the fiber or DSX-1.
DS1 ESF format
Tariffed service verification consists of monitoring performance parameters that can be associated with the customer’s end-to-end service. The DMX system provides this capability for DS1 services when equipped with 28DS1 circuit packs with the DS1 performance monitoring feature (28DS1PM [LNW7]) and the high density LNW8
56DS1/E1 circuit pack. Based on ANSI T1.403 extended superframe format (ESF), this capability retrieves performance messages written into the ESF data link by the customer’s terminal equipment. From these messages, DMX can determine and report the end-to-end error performance of the entire DS1 link as seen by the customer. The counts are retrieved by the message-based operations system to determine if the service is operating within tariffed limits.
DS1 SF format
Each 28DS1PM and 56DS1/E1 circuit packs measure the near-end performance of the incoming DS1 signals, allowing the service provider to determine if a good DS1 signal was received from the customer before transporting it through the network. This information can then aid in sectionalizing any reported performance problems. The
28DS1PM and 56DS1/E1 circuit packs can also provide this same near-end information for super frame (SF) formatted (sometimes known as “D4 framing”) DS1 services, but complete end-to-end performance verification is limited due to the lack of the PRM in the SF format.
365-372-300
Issue 8.0 September 2006
B - 4 7
DS1 Performance Monitoring Parameters
: Performance Monitoring
Monitored parameters
The following table lists the DS1 line and path performance parameters that DMX monitors, including the default and ranges for the 15-minute and 1-day (24-hour) registers.
Table B-10 DS1 Performance Parameters
Facility
DS1 Line
Measured Provisionable Parameter
Errored Seconds (ES-L), ES-LFE
Coding Violations (fmt=ESF)
(CV-L)
Severely Errored Seconds (SES-L)
Coding Violations (fmt=SF) (CV-P)
Coding Violations (fmt=ESF)
(CV-P)
Coding Violations
Far End (CV-PFE)
Errored Seconds (ES-P)
Errored Seconds
Far End
(ES-PFE)
15-Min
Default
Range
(Note)
Default
1-Day
Range
(Note)
65 0-900 648 0-65535
13340 0-16383 133400 0-1048575
65
72
0-900
0-16383
648
691
0-65535
0-1048575
13296 0-16383 132960 0-1048575
65 0-900 648 0-65535
DS1 Path
Severely Errored Seconds (SES-P)
Severely Errored Seconds
Far End
(SES-PFE)
Unavailable Seconds (UAS-P)
Unavailable Seconds Far End (UAS-PFE)
10
10
0-900
0-900
100
10
0-65535
0-65535
SE Frame/Alarm Indication Signal Seconds
(SAS-P)
SE Frame Seconds Far End (SEFS-PFE)
2 0-900 17 0-65535
Note: When an individual performance monitoring parameter threshold is provisioned as zero (0), TCA reporting for the affected parameter is disabled.
B - 4 8
DS1 line parameters
DMX monitors the following near end DS1 line parameter on incoming
(from the DSX-1 cross-connect) DS1 signals. The parameter is measured at the input of the DS1 circuit pack on the DS1 line side (also referred to as facility, customer terminal, or DSX side).
Coding violations (CV-L)
The Near-End Line Coding Violation (CVL) parameter for each
SONET Line is monitored. The Near-End CVL parameter increments once for every occurrence of a BIP error detected at the Line layer (i.e. using the B2 byte in the incoming SONET signal). Up to 8*N BIP errors can be detected per STS-N frame.
365-372-300
Issue 8.0 September 2006
DS1 Performance Monitoring Parameters
: Performance Monitoring
Errored seconds (ES-L)
The near end ES-L parameter increments once for each second during which DMX detects either one or more bipolar violations (BPVs) or excessive zeros (EXZ), or one or more LOS defects.
Severely errored seconds (SES-L)
The Near-End Line Severely Errored Seconds (SESL) parameter for each SONET Line is monitored. The Near-End SESL parameter increments once for every second that contains at least K BIP errors detected at the Line layer (at any point during the second), or an AIS-L defect was present. The value of K is hard-coded, see table 7 for a list of the values
DS1 Line PM Report
Use the
Performance > Reports > DS1 line
command to obtain the DS1
Line PM Report. Near end DS1 line PM is reported with an AID of the
DS1 interface and a modifier of T1. For more information about the
DS1 line parameter and the
Performance > Reports > DS1 line
command, refer to the WaveStar
®
CIT on-line help.
Near end DS1 path parameters
DMX monitors the following near end DS1 path parameters at the local network element. The parameters are measured at the input of the local
DS1 or TMUX circuit pack on the DS1 line side (also referred to as facility, customer terminal, or DSX side).
Coding violations (CV-P)
For the SF format, the CV-P parameter increments once for each frame synchronization bit error (FE) detected at the path level. For the ESF format, the CV-P parameter increments once for each cyclic redundancy check error (CRC) detected at the path level.
Errored seconds (ES-P)
For the SF format, he ES-P parameter increments once for each second during which DMX detects FE errors, CS events, SEF defects, or AIS defects. For the ESF format, he ES-P parameter increments once for each second during which DMX detects CRC errors, CS events, SEF defects, or AIS defects.
Severely errored seconds (SES-P)
For the SF format, the SES-P parameter increments once for each second during which DMX detects 8 or more FE events (if Ft and Fs
365-372-300
Issue 8.0 September 2006
B - 4 9
DS1 Performance Monitoring Parameters
: Performance Monitoring
bits are measured) or 4 or more FE events (if only Ft bits are monitored), or SEF defects, or AIS defects.
Unavailable seconds (UAS-P)
A UAS-P is a second during which the path is unavailable. A path is considered unavailable from the beginning of 10 consecutive severely errored seconds until the beginning of 10 consecutive seconds, none of which are severely errored.
Severely errored frame/alarm indication signal seconds (SAS-P)
The SAS-P parameter increments once for each second during which
DMX detects either one or more severely errored frame defects, or one or more AIS defects. The SAS-P parameter applies to SF and ESF frame formats.
Far end DS1 path parameters
Near End DS1 Path PM Report
Use the
Performance > Reports > DS1 path
command to obtain the DS1
Path PM Report. Near end DS1 path PM is reported with an AID of the
DS1 or TMUX interface and a modifier of T1. For more information about the DS1 path parameters and the
Performance > Reports > DS1 path
command, refer to the WaveStar
®
CIT on-line help.
DMX monitors the following far end DS1 path parameters at the local network element. If the far end network element detects an incoming error, the far end network element communicates the error back to the local near end network element using Performance Report Message
(PRM) frames or a Remote Alarm Indication (RAI) signal.
The far end parameters are measured at the input of the local DS1 or
TMUX circuit pack on the DS1 line side (also referred to as facility, customer terminal, or DSX side).
Important!
The format must be set to ESF to monitor the far end parameters (CV-PFE, ES-PFE, SES-PFE, and UAS-PFE).
B - 5 0
365-372-300
Issue 8.0 September 2006
DS1 Performance Monitoring Parameters
: Performance Monitoring
G4
G5
G6
G1
G2
G3
Coding violations Far End (CV-PFE)
The CV-PFE parameter increments based on the PRM G bits defined in the following table.
Table B-11 CV-PFE parameter increments
PRM Bit = 1
1
5
10
100
319
333
CV Count Accumulated
Errored seconds Far End (ES-PFE)
The ES-PFE parameter is a count of one second PRM intervals containing an RAI or RAI-CI signal, or a 1 in any of the following bits:
G1, G2, G3, G4, G5, G6, SE, or SL.
Severely errored seconds Far End (SES-PFE)
The SES-PFE parameter is a count of one second PRM intervals containing an RAI or RAI-CI signal or a 1 in any of the following bits:
G6 or SE.
Unavailable seconds Far End (UAS-PFE)
A UAS-PFE is a second during which the path is unavailable. A path is considered unavailable from the beginning of 10 consecutive severely errored seconds until the beginning of 10 consecutive seconds, none of which are severely errored.
365-372-300
Issue 8.0 September 2006
B - 5 1
DS1 Performance Monitoring Parameters
: Performance Monitoring
Severely errored frame seconds (SEFS-PFE)
The SEFS-PFE parameter is a count of 1 second PRM intervals that SE bit is equal to 1.
Far End DS1 Path PM Report
Use the
Performance > Reports > DS1 path
command to obtain the DS1
Path PM Report. Far end DS1 path PM is reported with an AID of the
DS1 or TMUX interface and a modifier of T1. For more information about the DS1 path parameters and the
Performance > Reports > DS1 path
command, refer to the WaveStar
®
CIT on-line help.
B - 5 2
365-372-300
Issue 8.0 September 2006
: Performance Monitoring
Ethernet/SAN Performance Monitoring Parameters
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Overview
DMX provides PM capabilities for the Fast Ethernet and Gigabit
Ethernet interfaces. PM data is collected at each LAN and WAN interface in the network for both incoming and outgoing directions and is stored in quarter-hour and day bins. The WAN interface provides a
Ethernet
Ethernet dropped frames (congestion)
(EDFC) (See Note 1)
0-72862694
Ethernet dropped frames (errors)
(EDFE) (Note 1)
0-72862694
0-6994818653
0-6994818653 connection to a SONET Virtual Concatenation Group (VCG).
TCAs
Provisionable threshold crossing alerts (TCAs) are not supported on the
Ethernet interfaces.
Monitored parameters
The following table lists the Ethernet performance parameters that
DMX monitors, including the ranges for the 15-minute and 1-day
(24-hour) registers.
Table B-12 Ethernet Performance Parameters
Facility Monitored Parameter
Ethernet
(all packs)
EDFC-- Ethernet dropped frames congestion
EDFE-- Ethernet dropped frames errors
EDFP-- Ethernet dropped frames - policer
EINB-- Incoming number of bytes
EINF--Incoming number of frames
EONB--Outgoing number of bytes
EONF-- Outgoing number of frames
15-Min
Range
0-72862694
0-72862694
TBS
TBS
TBS
TBS
TBS
1-Day
Range
0-6994818653
0-6994818653
TBS
TBS
TBS
TBS
TBS
365-372-300
Issue 8.0 September 2006
B - 5 3
Ethernet Performance Monitoring Parameters
: Performance Monitoring
Facility
LNW73 packs
LNW70 packs
Monitored Parameter
INTXWD-- Count of invalid transmission words received.
LOS--Count of instances of signal loss detected.
TBS
TBS
LSYNC--Count of instances of synchronization loss detected
DSPERR--Count of disparity errors received
TBS
TBS
RFOVD-- Count of received overflow frames dropped TBS
TFOVD--Count of transmit overflow frames dropped TBS
TFCRC--Count of transmitted frames with CRC errors TBS
T10BERR-- Count of transmitted 10B_ERR errors TBS
RCORH-- Count of received single-bit error corrected
GFP header count
TBS
RCRCH-- Count of received uncorrected multi-bit error
GFP header count
TBS
RCORF-- Count of received single-bit error corrected
GFP super-block count
EDFCG-- Dropped Green frames-congestion
EDFCY-- Dropped Yellow frames-congestion
EINDB-- Incoming number of dropped frames-broadcast/multicast rate limit
TBS
TBS
TBS
TBS
EINDP-- Incoming number of dropped PAUSE frames TBS
EINFU-- Incoming number of unicast frames TBS
EINFM-- Incoming number of multicast frames
EINFB-- Incoming number of broadcast frames
TBS
TBS
EONFU-- Outgoing number of unicast frames
EONFM-- Outgoing number of multicast frames
EONFB-- Outgoing number of broadcast frames
EINCP-- Number of frames trapped to CPU
EOCP-- Number of frames received from CPU
ALL-- All of the above monitored types
TBS
TBS
TBS
TBS
TBS
TBS
15-Min
Range
Notes:
1. Counter can overflow.
B - 5 4
TBS
TBS
TBS
TBS
TBS
TBS
TBS
TBS
TBS
TBS
TBS
TBS
TBS
TBS
TBS
TBS
TBS
TBS
TBS
TBS
TBS
TBS
TBS
TBS
1-Day
Range
365-372-300
Issue 8.0 September 2006
Ethernet Performance Monitoring Parameters
: Performance Monitoring
2. Does not apply to the LNW71 circuit pack.
Enabling/disabling
Performance monitoring is enabled/disabled via the WaveStar
®
CIT.
From the System View menu, select
Provision > Prov PM Ports
, then navigate to the port.
Ethernet parameters
DMX monitors several Ethernet parameters.
Ethernet dropped frames (congestion) (EDFC)
The EDFC parameter counts the number of incoming Ethernet frames dropped at a specific LAN/WAN port due to buffer overflow. Buffer overflow occurs when the network is congested.
For LNW70, this count represents the number of frames that could not be transmitted on the specified port because of congestion. For all other circuit packs, this count represents the number of frames that could not be received on the specified port because of congestion. This parameter does not apply to the LNW74 circuit pack.
Ethernet dropped frames (errors) (EDFE)
The EDFE parameter counts the number of incoming Ethernet frames dropped at a LAN/WAN port due to a frame check sequence (FCS) error or another defect in the frame.
For the LNW73: this count represents frames received with invalid CRC on data port. For VCG, this count represents dropped GFP super-block frames due to CRC error.
This parameter is valid only for VCGs - not LAN ports.
Ethernet dropped frames (policer) (EDFP)
This parameter is valid only for VCGs - not LAN ports. This parameter applies only to the LNW66/67/68 circuit packs.
Ethernet incoming number of bytes (EINB)
For the LNW73, ordered sets are not included in the count. This parameter is valid for the data ports only, not VCGs.
This parameter monitors the incoming number of bytes
Ethernet incoming number of frames (EINF)
This parameter monitors the incoming number of frames.
365-372-300
Issue 8.0 September 2006
B - 5 5
Ethernet Performance Monitoring Parameters
: Performance Monitoring
Ethernet outgoing number of bytes (EONB)
This parameter monitors the outgoing number of bytes. For the
LNW73, ordered sets are not included in the count. This parameter is valid for the data ports only, not VCGs.
Ethernet parameters for
LNW73 only
DMX monitors the following Ethernet parameters on the LNW73 pack.
Count of invalid transmission words received (INTXWD)
This parameter is valid for data ports only, not VCGs.
Count of instances for loss of signal detected (LOS)
This parameter is valid for data ports only, not VCGs.
Count of instances for sync loss detected (LSYNC)
This parameter is valid for data ports only, not VCGs.
Count of disparity errors received (DSPERR)
This parameter is valid for data ports only, not VCGs.
Count of received overflow frames dropped (RFOVD)
This parameter is valid for data ports only, not VCGs.
Count of transmit overflow frames dropped (TFOVD)
This parameter is valid for data ports only, not VCGs.
Count of transmitted frames with CRC errors (TFCRC)
This parameter is valid for data ports only, not VCGs.
Count of transmitted 10B_ERR errors (T10BERR)
This parameter is valid for data ports only, not VCGs.
Count of received single-bit error corrected GFP headers
(RCORH)
This parameter is valid for VCGs only, not data ports.
Count of received uncorrected multi-bit error GFP headers
(RCRCH)
This parameter is valid for VCGs only, not data ports.
B - 5 6
365-372-300
Issue 8.0 September 2006
Ethernet Performance Monitoring Parameters
: Performance Monitoring
Count of received single-bit error corrected GFP super-blocks
(RCORF)
This parameter is valid for VCGs only, not data ports.
Ethernet parameters for
LNW70 only
DMX monitors the following Ethernet parameters on the LNW70 pack.
Ethernet dropped green frames-- congestion (EDFCG)
This parameter the number of green frames that could not be transmitted due to congestion.
Ethernet dropped yellow frames-- congestion (EDFCG)
This parameter the number of yellow frames that could not be transmitted due to congestion.
Ethernet number of dropped frames-broadcast/multicast rate limit
(EINDB)
Ethernet number of incoming unicast frames (EINFU)
This parameter is valid for data ports only, not VCGs.
Ethernet incoming number of multicast frames (EINFM)
Multicast frames are frames where the destination address has the group address bit set to 1.
Ethernet incoming number of broadcast frames (EINFB)
Broadcast frames are frames where the destination address is all 1s.
Ethernet outgoing number of unicast frames (EONFU)
Ethernet outgoing number of broadcast frames (EINFB)
Broadcast frames are frames where the destination address is all 1s.
Ethernet number of frames trapped to CPU (EINCP)
Broadcast frames are frames where the destination address is all 1s.
Ethernet number for frames received from CPU (EOCP)
All of the above monitored parameters (ALL)
365-372-300
Issue 8.0 September 2006
B - 5 7
: Performance Monitoring
SNMP Parameters and Traps
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Overview
DMX supports the following functionality through the Simple Network
Management Protocol (SNMP) interface:
• SONET (DS1/E1 and DS3/EC-1) performance monitoring management information base (MIB) module that specifies
SONET performance monitoring and traps using the SONET
15-minute (Standard- RFC2558
) and 24-hour (Private) registers.
• Private Ethernet performance monitoring MIB module that specifies Ethernet performance monitoring and traps using the
SONET 15-minute and 24-hour registers.
• Standard Ethernet interface MIB module that specifies Ethernet port performance monitoring counts using the Ethernet continuous counter (RFC2863)
• Standard Ethernet performance monitoring MIB module for the
Ethernet-like Interface Types that specifies additional Ethernet port performance monitoring counts using the Ethernet continuous counter (RFC2358/RFC2665)
• Private VCG MIB module that specifies VCG traps
• Private MIB module for equipment information and equipment traps.
The MIB files are stored on the user’s pc in folder
C:/Program Files/Lucent Technologies/WaveStar CIT/generics/
dmx/3.1.0/p.
B - 5 8
365-372-300
Issue 8.0 September 2006
SNMP Parameters and Traps
: Performance Monitoring
Standard SONET PM MIB module
DMX supports a S
TANDARD
SONET PM MIB module defined in IETF
RFC2558. This module defines SONET PM parameters for the SONET physical medium, section layer, line, path and tributary. This Standard
SONET PM MIB module applies to individual SONET ports and tributaries.
Standard SONET PM MIB Module Parameters
The following table shows the Standard SONET PM MIB module parameters.
Group/Table
SonetMedium Group
SonetSectionCurrent Table
Parameters
sonetMediumType
(READ-ONLY)
Definition
value: “sonet” sonetMediumTimeElapsed sonetMediumValidIntervals seconds since the beginning of current period number of previous 15-min intervals for which data was collected (usually 32) sonetMediumLineCoding
(READ-ONLY) sonetMediumLineType
(READ-ONLY) sonetMediumCircuitIdentifier
(READ-ONLY) line coding,e.g., B3ZS short range single mode or long range single mode circuit ID sonetMediumInvalidIntervals number of intervals for which no data is available (usually 0) sonetMediumLoopbackConfig
(READ-ONLY) no loopback, facility loopback or terminalloopback sonetSectionCurrentStatus Current sonetSectionCurrentESs Current sonetSectionCurrentSESs sonetSectionCurrentSEFSs sonetSectionCurrentCVs
Current
Current
Current
365-372-300
Issue 8.0 September 2006
B - 5 9
SNMP Parameters and Traps
: Performance Monitoring
Group/Table Parameters
SonetSectionInterval Table
SonetLineCurrent Table sonetSectionIntervalESs 15 minute sonetSectionIntervalSEFSs sonetSectionIntervalCVs
15 minute
15 minute sonetSectionIntervalValidData 15 minute sonetLineCurrentStatus Current sonetLineCurrentESs sonetLineCurrentSESs sonetLineCurrentCVs sonetLineCurrentUASs
Current
Current
Current
Current
SonetLineInterval Table
SonetFarEndLineCurrent Table sonetLineIntervalESs sonetLineIntervalSESs sonetLineIntervalCVs sonetLineIntervalUASs sonetLineIntervalValidData sonetFarEndLineCurrentESs sonetFarEndLineCurrentSESs sonetFarEndLineCurrentCVs sonetFarEndLineCurrentUASs
15 minute
15 minute
15 minute
15 minute
15 minute
Current
Current
Current
Current
SonetFarEndLineInterval Table sonetFarEndLineIntervalESs sonetFarEndLineIntervalSESs sonetFarEndLineIntervalCVs
15 minute
15 minute
15 minute sonetFarEndLineIntervalUASs 15 minute sonetFarEndLineIntervalValidData 15 minute
Definition
B - 6 0
365-372-300
Issue 8.0 September 2006
SNMP Parameters and Traps
: Performance Monitoring
Group/Table
SonetPathCurrent Table
SonetPathInterval Table
SonetFarEndPathCurrent Table
SonetFarEndPathInterval Table
SonetVTCurrent Table
Parameters
sonetPathCurrentWidth sonetPathCurrentStatus sonetPathCurrentESs sonetPathCurrentSESs sonetPathCurrentCVs sonetPathCurrentUASs sonetPathIntervalNumber sonetPathIntervalESs sonetPathIntervalSESs sonetPathIntervalCVs sonetPathIntervalUASs sonetPathIntervalValidData sonetFarEndPathCurrentESs sonetFarEndPathCurrentSESs sonetFarEndPathCurrentCVs sonetFarEndPathCurrentUASs sonetFarEndPathIntervalNumber sonetFarEndPathIntervalESs sonetFarEndPathIntervalSESs sonetFarEndPathIntervalCVs sonetFarEndPathIntervalUASs
Current
Current
Current
Current
Current
Current
15 minute
15 minute
15 minute
15 minute
15 minute
15 minute
Current
Current
Current
Current
15 minute
15 minute
15 minute
15 minute
15 minute sonetFarEndPathIntervalValidData 15 minute sonetVTCurrentWidth Current
Definition
sonetVTCurrentStatus sonetVTCurrentESs sonetVTCurrentSESs sonetVTCurrentCVs sonetVTCurrentUASs
Current
Current
Current
Current
Current
365-372-300
Issue 8.0 September 2006
B - 6 1
SNMP Parameters and Traps
: Performance Monitoring
Group/Table
SonetVTInterval Table
SonetFarEndVTCurrent Table
SonetFarEndVTInterval Table
Parameters
sonetVTIntervalNumber sonetVTIntervalESs sonetVTIntervalSESs sonetVTIntervalCVs sonetVTIntervalUASs sonetVTIntervalValidData sonetFarEndVTCurrentESs sonetFarEndVTCurrentSESs sonetFarEndVTCurrentCVs sonetFarEndVTCurrentUASs sonetFarEndVTIntervalNumber sonetFarEndVTIntervalESs sonetFarEndVTIntervalSESs sonetFarEndVTIntervalCVs sonetFarEndVTIntervalUASs sonetFarEndVTIntervalValidData
15 minute
15 minute
15 minute
15 minute
15 minute
15 minute
Current
Current
Current
Current
15 minute
15 minute
15 minute
15 minute
15 minute
15 minute
Definition
Private SONET Day PM MIB Module
DMX supports private SONET Day PM MIB Module. This module defines 24 hour SONET PM parameters for the SONET physical medium, section layer, line, path and tributary. This MIB module shall apply to individual SONET ports and tributaries.
Table
dmxSonetSectionDay Table
Parameters
dmxSonetSectionDayNumber dmxSonetSectionDayESs dmxSonetSectionDaySESs dmxSonetSectionDaySEFSs dmxSonetSectionDayCVs dmxSonetSectionDayValidData
B - 6 2
365-372-300
Issue 8.0 September 2006
SNMP Parameters and Traps
: Performance Monitoring
Table
dmxSonetLineDay Table dmxSonetFarEndLineDay Table dmxSonetPathDay Table dmxSonetFarEndPathDay Table
Parameters
dmxSonetLineDayNumber dmxSonetLineDayESs dmxSonetLineDaySESs dmxSonetLineDayCVs dmxSonetLineDayUASs dmxSonetLineDayValidData dmxSonetFarEndLineDayNumber dmxSonetFarEndLineDayESs dmxSonetFarEndLineDaySESs dmxSonetFarEndLineDayCVs dmxSonetFarEndLineDayUASs dmxSonetFarEndLineDayValidData dmxSonetPathDayNumber dmxSonetPathDayESs dmxSonetPathDaySESs dmxSonetPathDayCVs dmxSonetPathDayUASs dmxSonetPathDayValidData dmxSonetFarEndPathDayNumber dmxSonetFarEndPathDayESs dmxSonetFarEndPathDaySESs dmxSonetFarEndPathDayCVs dmxSonetFarEndPathDayUASs dmxSonetFarEndPathDayValidData
365-372-300
Issue 8.0 September 2006
B - 6 3
SNMP Parameters and Traps
Table
dmxSonetVTDay Table dmxSonetFarEndVTDay Table
Parameters
dmxSonetVTDayNumber dmxSonetVTDayESs dmxSonetVTDaySESs dmxSonetVTDayCVs dmxSonetVTDayUASs dmxSonetVTDayValidData dmxSonetFarEndVTDayNumber dmxSonetFarEndVTDayESs dmxSonetFarEndVTDaySESs dmxSonetFarEndVTDayCVs dmxSonetFarEndVTDayUASs dmxSonetFarEndVTDayValidData
: Performance Monitoring
B - 6 4
365-372-300
Issue 8.0 September 2006
SNMP Parameters and Traps
: Performance Monitoring
Alarm Identifiers for Alarm and Event Traps
In addition to standard SNMP traps, DMX supports the following five traps for all NE alarms: Alarms (dmxAlarm), Alarm Clears
(dmxAlarmCL), Standing Conditions (dmxStandingCond), Standing
Condition Clears (dmxStandingCondCL), and Transient Conditions
(dmxTransientCond).
365-372-300
Issue 8.0 September 2006
B - 6 5
SNMP Parameters and Traps
: Performance Monitoring
Standard DS1/E1 PM MIB Module
The following table shows the Standard DS1/E1 PM MIB tables and parameters defined in IETF RFC2495. This MIB module applies to individual DS1/E1 ports
.
B - 6 6
365-372-300
Issue 8.0 September 2006
SNMP Parameters and Traps
Table
Dsx1ConfigEntry Table
: Performance Monitoring
Parameters
dsx1LineIndex dsx1TimeElapsed dsx1ValidIntervals dsx1LineType dsx1LineCoding dsx1SendCode dsx1CircuitIdentifier dsx1LoopbackConfig dsx1LineStatus dsx1SignalMode dsx1TransmitClockSource dsx1Fdl dsx1InvalidIntervals dsx1LineLength dsx1LineStatusLastChange dsx1LineStatusChangeTrapEnable dsx1LoopbackStatus dsx1Ds1ChannelNumber dsx1Channelization
Description
ifIndex seconds since the beginning of current period number of previous 15-min intervals for which data was collected (usually 32) type of DS1/E1 line, e.g., E1 unframed line coding, e.g. B8ZS code being sent circuit ID: 0,...,255 loopback configuration bit mapped line status information signaling mode loop timing, local timing or through timing facilities data link capabilities number of intervals for which no data is available (usually 0) length of the DS1/E1 line in meters time this DS1/E1 entered its current line status state indicates whether dsx1LineStatusChange traps should be generated for this DS1/E1 current state of the loopback on the
DS1/E1 interface
0..28
DS1/E1 channelization: disabled, enabled DS0 or enabled DS1
365-372-300
Issue 8.0 September 2006
B - 6 7
SNMP Parameters and Traps
Table
Dsx1CurrentEntry Table
Dsx1IntervalEntry Table
Parameters
dsx1CurrentIndex dsx1CurrentESs dsx1CurrentSESs dsx1CurrentSEFSs dsx1CurrentUASs dsx1CurrentCSSs dsx1CurrentPCVs dsx1CurrentLESs dsx1CurrentBESs dsx1CurrentDMs dsx1CurrentLCVs dsx1IntervalIndex dsx1IntervalNumber dsx1IntervalESs dsx1IntervalSESs dsx1IntervalSEFSs dsx1IntervalUASs dsx1IntervalCSSs dsx1IntervalPCVs dsx1IntervalLESs dsx1IntervalBESs dsx1IntervalDMs dsx1IntervalLCVs dsx1IntervalValidData
: Performance Monitoring
Current
Current
Current
Current
Current
Current
Current
Current
Current
Current
Current
15 minute
15 minute
15 minute
15 minute
15 minute
15 minute
15 minute
15 minute
15 minute
15 minute
15 minute
15 minute
15 minute
Description
B - 6 8
365-372-300
Issue 8.0 September 2006
SNMP Parameters and Traps
Table
Dsx1TotalEntry Table
Dsx1ChanMappingEntry Table
Dsx1FarEndCurrentEntry Table
Parameters
dsx1TotalIndex dsx1TotalESs dsx1TotalSESs dsx1TotalSEFSs dsx1TotalUASs dsx1TotalCSSs dsx1TotalPCVs dsx1TotalLESs dsx1TotalBESs dsx1TotalDMs dsx1TotalLCVs dsx1ChanMappedIfIndex dsx1FarEndCurrentIndex dsx1FarEndTimeElapsed dsx1FarEndValidIntervals dsx1FarEndCurrentESs dsx1FarEndCurrentSESs dsx1FarEndCurrentSEFSs dsx1FarEndCurrentUASs dsx1FarEndCurrentCSSs dsx1FarEndCurrentLESs dsx1FarEndCurrentPCVs dsx1FarEndCurrentBESs dsx1FarEndCurrentDMs dsx1FarEndInvalidIntervals
Current
Current
Current
Current
Current
Current
Current
Current
Current
: Performance Monitoring
Description
24 hour
24 hour
24 hour
24 hour
24 hour
24 hour
24 hour
24 hour
24 hour
24 hour
24 hour
DS1/E1 channel number ifIndex
Current
Current
Current
Current
365-372-300
Issue 8.0 September 2006
B - 6 9
SNMP Parameters and Traps
: Performance Monitoring
Table
Dsx1FarEndIntervalEntry Table
Dsx1FarEndTotalEntry Table
Parameters
dsx1FarEndIntervalIndex dsx1FarEndIntervalNumber dsx1FarEndIntervalESs dsx1FarEndIntervalSESs dsx1FarEndIntervalSEFSs dsx1FarEndIntervalUASs dsx1FarEndIntervalCSSs dsx1FarEndIntervalLESs dsx1FarEndIntervalPCVs dsx1FarEndIntervalBESs dsx1FarEndIntervalDMs dsx1FarEndIntervalValidData dsx1FarEndTotalIndex dsx1FarEndTotalESs dsx1FarEndTotalSESs dsx1FarEndTotalSEFSs dsx1FarEndTotalUASs dsx1FarEndTotalCSSs dsx1FarEndTotalLESs dsx1FarEndTotalPCVs dsx1FarEndTotalBESs dsx1FarEndTotalDMs
24 hour
24 hour
24 hour
24 hour
24 hour
24 hour
24 hour
15 minute
15 minute
15 minute
15 minute
15 minute
15 minute
15 minute
15 minute
15 minute
15 minute
15 minute
15 minute
24 hour
24 hour
24 hour
Description
Standard DS1 Traps
DMX supports the following DS1 trap.
Table Parameters
ds1Traps dsx1LineStatusChange
B - 7 0
365-372-300
Issue 8.0 September 2006
SNMP Parameters and Traps
Table
Dsx3ConfigEntry
: Performance Monitoring
Standard DS3/EC-1 PM MIB Module
The following table shows the Standard DS3/EC-1 PM MIB tables and parameters defined in IETF RFC2496. This MIB module applies to individual DS3/EC-1 ports
.
Parameters
dsx3LineIndex dsx3TimeElapsed dsx3ValidIntervals dsx3LineType dsx3LineCoding dsx3SendCode dsx3CircuitIdentifier dsx3LoopbackConfig dsx3LineStatus dsx3TransmitClockSource dsx3InvalidIntervals dsx3LineLength dsx3LineStatusLastChange dsx3LineStatusChangeTrapEnable dsx3LoopbackStatus dsx3Channelization dsx3Ds1ForRemoteLoop
Description
ifIndex seconds since the beginning of current period number of previous 15-min intervals for which data was collected
(usually 32) type of DS3/E3 line line coding, e.g. B3ZS code being sent
N/A - always “0” loopback configuration bit mapped line status information loop timing, local timing or through timing number of intervals for which no data is available (usually 0) length of the DS3/E3 line in meters time this DS3/E3 entered its current line status state indicates whether dsx3LineStatusChange traps should be generated for this DS3/E3 - read only current state of the loopback on the
DS3/E3 interface
“enabled DS1” if CP is TMUX, otherwise “disabled” not supported, always “0”
365-372-300
Issue 8.0 September 2006
B - 7 1
SNMP Parameters and Traps
Table
Dsx3CurrentEntry
Parameters
dsx3CurrentIndex dsx3CurrentPESs dsx3CurrentPSESs dsx3CurrentSEFSs dsx3CurrentUASs dsx3CurrentLCVs dsx3CurrentPCVs dsx3CurrentLESs dsx3CurrentCCVs dsx3CurrentCESs dsx3CurrentCSESs
: Performance Monitoring
Description
Current
Current - valid only if
ENT-rr:
fmt=PBIT, otherwise “0”
Current - valid only if
ENT-rr:
fmt=PBIT, otherwise “0”
Current
Current
Current
Current - valid only if
ENT-rr:
fmt=PBIT, otherwise “0”
Current
Current - valid only if
ENT-rr:
fmt=CPBIT, otherwise
“0”
Current - valid only if
ENT-rr:
fmt=CPBIT, otherwise
“0”
Current - valid only if
ENT-rr:
fmt=CPBIT, otherwise
“0”
B - 7 2
365-372-300
Issue 8.0 September 2006
SNMP Parameters and Traps
Table
Dsx3IntervalEntry
Parameters
dsx3IntervalIndex dsx3IntervalNumber dsx3IntervalPESs dsx3IntervalPSESs dsx3IntervalSEFSs dsx3IntervalUASs dsx3IntervalLCVs dsx3IntervalPCVs dsx3IntervalLESs dsx3IntervalCCVs dsx3IntervalCESs dsx3IntervalCSESs dsx3IntervalValidData
: Performance Monitoring
Description
Current
15 minute
15 minute - valid only if
ENT-rr:
fmt=PBIT, otherwise “0”
15 minute - valid only if
ENT-rr:
fmt=PBIT, otherwise “0”
15 minute
15 minute
15 minute
15 minute - valid only if
ENT-rr:
fmt=PBIT, otherwise “0”
15 minute
15 minute - valid only if
ENT-rr:
fmt=CPBIT, otherwise
“0”
15 minute - valid only if
ENT-rr:
fmt=CPBIT, otherwise
“0”
15 minute - valid only if
ENT-rr:
fmt=CPBIT, otherwise
“0”
15 minute
365-372-300
Issue 8.0 September 2006
B - 7 3
SNMP Parameters and Traps
Table
Dsx3TotalEntry
Dsx3FarEndConfigEntry
: Performance Monitoring
Parameters
dsx3TotalIndex dsx3TotalPESs dsx3TotalPSESs dsx3TotalSEFSs dsx3TotalUASs dsx3TotalLCVs dsx3TotalPCVs dsx3TotalLESs dsx3TotalCCVs dsx3TotalCESs dsx3TotalCSESs dsx3FarEndLineIndex dsx3FarEndEquipCode dsx3FarEndLocationIDCode dsx3FarEndFrameIDCode dsx3FarEndUnitCode dsx3FarEndFacilityIDCode
Description
24 hour
24 hour - valid only if
ENT-rr:
fmt=PBIT, otherwise “0”
24 hour - valid only if
ENT-rr:
fmt=PBIT, otherwise “0”
24 hour
24 hour
24 hour
24 hour - valid only if
ENT-rr:
fmt=PBIT, otherwise “0”
24 hour
24 hour - valid only if
ENT-rr:
fmt=CPBIT, otherwise
“0”
24 hour - valid only if
ENT-rr:
fmt=CPBIT, otherwise
“0”
24 hour - valid only if
ENT-rr:
fmt=CPBIT, otherwise
“0” not supported not supported not supported not supported not supported not supported
B - 7 4
365-372-300
Issue 8.0 September 2006
SNMP Parameters and Traps
Table
Dsx3FarEndCurrentEntry
Dsx3FarEndIntervalEntry
: Performance Monitoring
Parameters
dsx3FarEndCurrentIndex dsx3FarEndTimeElapsed dsx3FarEndValidIntervals dsx3FarEndCurrentCESs dsx3FarEndCurrentCSESs dsx3FarEndCurrentCCVs dsx3FarEndCurrentUASs dsx3FarEndInvalidIntervals dsx3FarEndIntervalIndex dsx3FarEndIntervalNumber dsx3FarEndIntervalCESs dsx3FarEndIntervalCSESs dsx3FarEndIntervalCCVs dsx3FarEndIntervalUASs dsx3FarEndIntervalValidData
Description
not supported (moved to Private
DS3 PM MIB) not supported (moved to Private
DS3 PM MIB) not supported (moved to Private
DS3 PM MIB) not supported (moved to Private
DS3 PM MIB) not supported (moved to Private
DS3 PM MIB) not supported (moved to Private
DS3 PM MIB) not supported (moved to Private
DS3 PM MIB) not supported (moved to Private
DS3 PM MIB) not supported (moved to Private
DS3 PM MIB) not supported (moved to Private
DS3 PM MIB) not supported (moved to Private
DS3 PM MIB) not supported (moved to Private
DS3 PM MIB) not supported (moved to Private
DS3 PM MIB) not supported (moved to Private
DS3 PM MIB) not supported (moved to Private
DS3 PM MIB)
365-372-300
Issue 8.0 September 2006
B - 7 5
SNMP Parameters and Traps
: Performance Monitoring
Table
Dsx3FarEndTotalEntry
Parameters
dsx3FarEndTotalIndex dsx3FarEndTotalCESs dsx3FarEndTotalCSESs dsx3FarEndTotalCCVs dsx3FarEndTotalUASs
Description
not supported (moved to Private
DS3 PM MIB) not supported (moved to Private
DS3 PM MIB) not supported (moved to Private
DS3 PM MIB) not supported (moved to Private
DS3 PM MIB) not supported (moved to Private
DS3 PM MIB)
DS3 Traps
Standard DS3 Traps
DMX supports the following DS3 trap.
Table Parameters
dsx3LineStatusChange
B - 7 6
365-372-300
Issue 8.0 September 2006
SNMP Parameters and Traps
: Performance Monitoring
Table
DmxDmxDsx3CurrentEntry
DmxDmxDsx3IntervalEntry
DmxDmxDsx3TotalEntry
Private DS3/EC-1 PM MIB Module
DMX supports private DS3/EC-1 PM MIB Module. This MIB module shall apply to individual DS3/EC-1 ports and tributaries..
Parameters
dmxDsx3CurrentIndex dmxDsx3CurrentFMESs dmxDsx3CurrentFMSESs dmxDsx3CurrentFMCVs dmxDsx3IntervalIndex dmxDsx3IntervalFMESs dmxDsx3IntervalFMSESs dmxDsx3IntervalFMCVs
Description
Current
Current - valid only if
ENT-rr
:fmt=FMBIT, otherwise “0”
Current - valid only if
ENT-rr
:fmt=FMBIT, otherwise “0””
Current - valid only if
ENT-rr
:fmt=FMBIT, otherwise “0”
Interval
Interval - valid only if
ENT-rr
:fmt=FMBIT, otherwise “0”
Interval - valid only if
ENT-rr
:fmt=FMBIT, otherwise “0””
Interval - valid only if
ENT-rr
:fmt=FMBIT, otherwise “0” dsx3DMXIntervalValidData dmxDsx3TotalIndex dmxDsx3TotalFMESs dmxDsx3TotalFMSESs dmxDsx3TotalFMCVs
Total
Total - valid only if
ENT-rr
:fmt=FMBIT, otherwise “0”
Total - valid only if
ENT-rr
:fmt=FMBIT, otherwise “0””
Total - valid only if
ENT-rr
:fmt=FMBIT, otherwise “0”
365-372-300
Issue 8.0 September 2006
B - 7 7
SNMP Parameters and Traps
: Performance Monitoring
Table
DmxDsx3FarEndCurrentEntry
DmxDsx3FarEndIntervalEntry
DmxDsx3FarEndTotalEntry
Parameters
dmxDsx3FarEndCurrentIndex dmxDsx3FarEndTimeElapsed dmxDsx3FarEndValidIntervals dmxDsx3FarEndCurrentCFMESs dmxDsx3FarEndCurrentCFMSESs dmxDsx3FarEndCurrentCFMCVs dmxDsx3FarEndCurrentUASs
Description
Current
Current
Current
Current - far end PM based on
C-bit, F-bit and M-bit errors
Current - far end PM based on
C-bit, F-bit and M-bit errors
Current - far end PM based on
C-bit, F-bit and M-bit errors
Current - far end PM based on
C-bit, F-bit and M-bit errors
Current
15 minute dmxDsx3FarEndInvalidIntervals dmxDsx3FarEndIntervalIndex dmxDsx3FarEndIntervalNumber dmxDsx3FarEndIntervalCFMESs dmxDsx3FarEndIntervalCFMSESs dmxDsx3FarEndIntervalCFMCVs
15 minute
15 minute - far end PM based on
C-bit, F-bit and M-bit errors
15 minute - far end PM based on
C-bit, F-bit and M-bit errors
15 minute - far end PM based on
C-bit, F-bit and M-bit errors dmxDsx3FarEndIntervalUASs
15 minute - far end PM based on
C-bit, F-bit and M-bit errors dmxDsx3FarEndIntervalValidData 15 minute dmxDsx3FarEndTotalIndex dmxDsx3FarEndTotalCFMESs
24 hour
24 hour - far end PM based on
C-bit, F-bit and M-bit errors dmxDsx3FarEndTotalCFMSESs dmxDsx3FarEndTotalCFMCVs dmxDsx3FarEndTotalUASs
24 hour - far end PM based on
C-bit, F-bit and M-bit errors
24 hour - far end PM based on
C-bit, F-bit and M-bit errors
24 hour - far end PM based on
C-bit, F-bit and M-bit errors
B - 7 8
365-372-300
Issue 8.0 September 2006
SNMP Parameters and Traps
: Performance Monitoring
Private Ethernet PM MIB module
DMX supports a private Ethernet PM MIB module for Ethernet traps and for retrieving Ethernet PM parameters. This private Ethernet PM
MIB module applies to individual Fast Ethernet and Gigabit Ethernet ports.
Private Ethernet PM MIB Module Parameters
The following table shows the private Ethernet PM MIB module parameters.
Object Parameter
dmxEthPmonTypeCurrent port type dmxEthPmonCurrentEinf dmxEthPmonCurrentEdfc dmxEthPmonCurrentEonb dmxEthPmonCurrentEonf dmxEthPmonIntervalIndex dmxEthPmonTypeInterval dmxEthPmonIntervalEinb dmxEthPmonIntervalEinf dmxEthPmonIntervalEdfc dmxEthPmonIntervalEdfe dmxEthPmonIntervalEonb dmxEthPmonIntervalEonf dmxEthPmonDayIndex dmxEthPmonDayType
Incoming number of frames (EINF)
Dropped frames: congestion (EDFC)
Outgoing number of bytes (EONB)
Outgoing number of frames (EONF)
15 minute bucket index port type
Incoming number of bytes (EINB)
Incoming number of frames (EINF)
Dropped frames: congestion (EDFC)
Dropped frames: errors (EDFE)
Outgoing number of bytes (EONB)
Outgoing number of frames (EONF) day index port type
Definition
FE or GbE port
Total Bytes Received
Frames Received or Total
Frames Received
Dropped Frames
CRC Error + Oversize Frames +
Fragments + Jabber + MAC Rx
Error a
Bytes Sent
Frames Sent
1 to 32
FE or GbE port
Total Bytes Received: 15 minute
Frames Received or Total
Frames Received: 15 minute
Dropped Frames: 15 minute
CRC Error + Oversize Frames
+ Fragments + Jabber + MAC
Rx Error: 15 minute
Bytes Sent: 15 minute
Frames Sent: 15 minute current or previous 24 hour period
FE or GbE port
365-372-300
Issue 8.0 September 2006
B - 7 9
SNMP Parameters and Traps
: Performance Monitoring
Object Parameter
dmxEthPmonDayEinb Incoming number of bytes (EINB) dmxEthPmonDayEinf dmxEthPmonDayEdfc
Incoming number of frames (EINF)
Dropped frames: congestion (EDFC) dmxEthPmonDayEdfe Dropped frames: errors (EDFE) dmxEthPmonDayEonb dmxEthPmonDayEonf dmxEthPmonCurrentEdfb dmxEthPmonCurrentEdfcg dmxEthPmonCurrentEdfcy dmxEthPmonCurrentEindp dmxEthPmonCurrentEincp dmxEthPmonCurrentEinfb dmxEthPmonCurrentEinfm dmxEthPmonCurrentEinfu dmxEthPmonCurrentEocp dmxEthPmonCurrentEonfb dmxEthPmonCurrentEonfm dmxEthPmonCurrentEonfu dmxEthPmonIntervalEdfb
Outgoing number of bytes (EONB)
Outgoing number of frames (EONF) dropped frames - broadcast rate limit
(EDFB) dropped green frames - congestion
(EDFCG) dropped yellow frames - congestion
(EDFCY) dropped PAUSE frames (EINDP) number of frames trapped to CPU
(EINCP) incoming number of broadcast frames
(EINFB) incoming number of multicast frames
(EINFM) incoming number of unicast frames
(EINFU) number of frames received from CPU
(EOCP) outgoing number of broadcast frames
(EONFB) outgoing number of multicast frames
(EONFM) outgoing number of unicast frames
(EONFU) dropped frames - broadcast rate limit
(EDFB)
B - 8 0
Definition
Total Bytes Received: 24 hour
Frames Received or Total
Frames Received: 24 hour
Dropped Frames: 24 hour
CRC Error + Oversize Frames
+ Fragments + Jabber + MAC
Rx Error: 24 hour
Bytes Sent: 24 hour
Frames Sent: 24 hour
LNW70 only
LNW70 only
LNW70 only
LNW70 only
LNW70 only
LNW70 only
LNW70 only
LNW70 only
LNW70 only
LNW70 only
LNW70 only
LNW70 only
15 minute - LNW70 only
365-372-300
Issue 8.0 September 2006
SNMP Parameters and Traps
: Performance Monitoring
Object Parameter
dmxEthPmonIntervalEdfcg dropped green frames - congestion
(EDFCG) dmxEthPmonIntervalEdfcy dmxEthPmonIntervalEindp dmxEthPmonIntervalEincp dmxEthPmonIntervalEinfb dropped yellow frames - congestion
(EDFCY) dropped PAUSE frames (EINDP) number of frames trapped to CPU
(EINCP) incoming number of broadcast frames
(EINFB) dmxEthPmonIntervalEinfm dmxEthPmonIntervalEinfu dmxEthPmonIntervalEocp dmxEthPmonIntervalEonfb dmxEthPmonIntervalEonfm dmxEthPmonIntervalEonfu dmxEthPmonDayEdfb dmxEthPmonDayEdfcg dmxEthPmonDayEdfcy dmxEthPmonDayEindp dmxEthPmonDayEincp dmxEthPmonDayEinfb dmxEthPmonDayEinfm incoming number of multicast frames
(EINFM) incoming number of unicast frames
(EINFU) number of frames received from CPU
(EOCP) outgoing number of broadcast frames
(EONFB) outgoing number of multicast frames
(EONFM) outgoing number of unicast frames
(EONFU) dropped frames - broadcast rate limit
(EDFB) dropped green frames - congestion
(EDFCG) dropped yellow frames - congestion
(EDFCY) dropped PAUSE frames (EINDP) number of frames trapped to CPU
(EINCP) incoming number of broadcast frames
(EINFB) incoming number of multicast frames
(EINFM)
365-372-300
Issue 8.0 September 2006
Definition
15 minute - LNW70 only
15 minute - LNW70 only
15 minute - LNW70 only
15 minute - LNW70 only
15 minute - LNW70 only
15 minute - LNW70 only
15 minute - LNW70 only
15 minute - LNW70 only
15 minute - LNW70 only
15 minute - LNW70 only
15 minute - LNW70 only
24 hour - LNW70 only
24 hour - LNW70 only
24 hour - LNW70 only
24 hour - LNW70 only
24 hour - LNW70 only
24 hour - LNW70 only
24 hour - LNW70 only
B - 8 1
SNMP Parameters and Traps
: Performance Monitoring
Object Parameter
dmxEthPmonDayEinfu incoming number of unicast frames
(EINFU) dmxEthPmonDayEocp dmxEthPmonDayEonfb dmxEthPmonDayEonfm dmxEthPmonDayEonfu number of frames received from CPU
(EOCP) outgoing number of broadcast frames
(EONFB) outgoing number of multicast frames
(EONFM) outgoing number of unicast frames
(EONFU)
Definition
24 hour - LNW70 only
24 hour - LNW70 only
24 hour - LNW70 only
24 hour - LNW70 only
24 hour - LNW70 only a.
The definition of Dropped Frames is based on the counters supported by the Galnet devices. The definition of this parameter for the private line board, which doesn’t have the Galnet devices, may differ.
Trap Object
dmxIncFeLanLos dmxIncFeLanLosClr dmxIncFeLanAnm dmxIncFeLanAnmClr dmxIncGeLanLos dmxIncGeLanLosClr
Private Ethernet PM MIB Module Traps
The following table shows the private Ethernet PM MIB module traps.
Definition
Loss of signal (LOS) on FE LAN port
LOS clear on FE LAN port
Auto-Negotiation Mismatch (ANM) on FE LAN port
ANM clear on FE LAN port
Loss of signal (LOS) on GbE LAN port
LOS clear on GbE LAN port dmxIncGeLanAnmClr dmxIncGeLanECV dmxIncGeLanECVClr dmxIncGeLanTEDFC dmxIncFeLanTEDFC dmxIncGeLanTEDFE dmxIncFeLanTEDFE
B - 8 2
ANM clear on GbE LAN port
Excessive Code Violation on GbE LAN port
Excessive Code Violation clear on GbE LAN port
Dropped frames due to congestion TCA on GbE LAN port
Dropped frames due to congestion TCA on FE LAN port
Dropped frames due to errors TCA on GbE LAN port
Dropped frames due to errors TCA on FE LAN port
365-372-300
Issue 8.0 September 2006
SNMP Parameters and Traps
: Performance Monitoring
Private Ethernet PM MIB module QOS Parameters
DMX supports private Ethernet PM MIB module for retrieving QOS parameters. This private Ethernet PM MIB module applies to individual Fast Ethernet and Gigabit Ethernet ports for the LNW70 pack.
Private Ethernet PM MIB Module QOS Parameters
The following table shows the private Ethernet PM MIB module QOS parameters.
Object Parameter
dmxEthPmonQosCurrentTagid
VLANid in the range 1-4093 except for
PORT and COSPORT mode which has a value of “NA” dmxEthPmonQosCurrentCos Class of Service in the range 0-3 dmxEthPmonQosCurrentQibg Incoming bytes marked green (QIB-G) dmxEthPmonQosCurrentQipg Incoming packets marked green (QIP-G) dmxEthPmonQosCurrentQiby Incoming bytes marked yellow (QIB-Y) dmxEthPmonQosCurrentQipy Incoming packets marked yellow (QIP-Y) dmxEthPmonQosCurrentQibr
Incoming bytes marked red (dropped)
(QIB-R) dmxEthPmonQosCurrentQipr
Incoming packets marked red (dropped)
(QIP-R ) dmxEthPmonQosIntervalIndex 15 minute bucket index 1 to 32 dmxEthPmonQosIntervalTagid
VLANid in the range 1-4093 except for
PORT and COSPORT modewhich has a value of “NA”
Class of Service in the range 0-3
15 minute dmxEthPmonQosIntervalCos 15 minute dmxEthPmonQosIntervalQibg Incoming bytes marked green (QIB-G) 15 minute dmxEthPmonQosIntervalQipg Incoming packets marked green (QIP-G) 15 minute dmxEthPmonQosIntervalQiby Incoming bytes marked yellow (QIB-Y) 15 minute dmxEthPmonQosIntervalQipy Incoming packets marked yellow (QIP-Y) 15 minute dmxEthPmonQosIntervalQibr dmxEthPmonQosIntervalQipr
Incoming bytes marked red (dropped)
(QIB-R)
Incoming packets marked red (dropped)
(QIP-R )
15 minute
15 minute
Definition
365-372-300
Issue 8.0 September 2006
B - 8 3
SNMP Parameters and Traps
: Performance Monitoring
Object Parameter
dmxEthPmonQosDayIndex dmxEthPmonQosDayTagid dmxEthPmonQosDayCos dmxEthPmonQosDayQibg dmxEthPmonQosDayQipg dmxEthPmonQosDayQiby dmxEthPmonQosDayQipy dmxEthPmonQosDayQibr dmxEthPmonQosDayQipr day index
VLANid in the range 1-4093 except for
PORT and COSPORT modewhich has a value of “NA”
Class of Service in the range 0-3
24 hour
24 hour
Incoming bytes marked green (QIB-G) 24 hour
Incoming packets marked green (QIP-G) 24 hour
Incoming bytes marked yellow (QIB-Y)
Incoming packets marked yellow (QIP-Y)
Incoming bytes marked red (dropped)
(QIB-R)
Incoming packets marked red (dropped)
(QIP-R )
Definition
current or previous 24 hour period
24 hour
24 hour
24 hour
24 hour
B - 8 4
365-372-300
Issue 8.0 September 2006
SNMP Parameters and Traps
: Performance Monitoring
Fibre
Channel/ESCON/FICON private MIB module
DMX supports a private Fibre Channel/ESCON/FICON PM MIB module for retrieving Fibre Channel/ESCON/FICON PM parameters.
This private MIB module shall apply to individual ports for the
LNW73 circuit pack.
Private FC/ESCON/FICON MIB Module PM QOS Parameters
The following table shows the private Ethernet PM MIB module QOS parameters.
Table
dmxPortStatCountCurrentTable
Object Parameter
dmxPortStatCountCurrentRx
Elements dmxPortStatCountCurrentRx
Objects
The number of octets or bytes that have been received by this port. (EINB).
Note: for Fibre Channel, ordered sets are not included in the count.
The number of frames/packets that have been received by this port. (EINF)
Note: A Fibre Channel frame starts with
SOF and ends with EOF dmxPortStatCountCurrentInv alidCRC dmxPortStatCountCurrentInv alidTxWords dmxPortStatCountCurrentLos sofSignal dmxPortStatCountCurrentLos sofSynchronization dmxPortStatCountCurrentEnc odingDisparityErrors dmxPortStatCountCurrentTx
Elements dmxPortStatCountCurrentTx
Objects
Count of frames received with invalid
CRC (EDFE)
Count of invalid transmission words received at this port (INTXWD)
Count of instances of signal loss detected at port (LOS)
Count of instances of synchronization
(LSYNC)
Count of disparity errors received at this port (DSPERR)
The number of octets or bytes that have been transmitted by this port. (EONB)
Note: for Fibre Channel, ordered sets are not included in the count.
The number of frames/packets/ IOs/etc. that have been transmitted by this port.
(EONF) Note: A Fibre Channel frame starts with SOF and ends with EOF
Definition
365-372-300
Issue 8.0 September 2006
B - 8 5
SNMP Parameters and Traps
: Performance Monitoring
Table Object Parameter
dmxPortStatCountCurrentRx
OverflowFramesDropped
Count of received overflow frames dropped (RFOVD) dmxPortStatCountCurrentTx
OverflowFramesDropped dmxPortStatCountCurrentTxF ramesCRCErrors dmxPortStatCountCurrentTx1
0BERRErrors dmxPortStatCountIntervalTable dmxPortStatCountIntervalInd ex
Count of transmit overflow frames dropped (TFOVD)
Count of transmitted frames with CRC errors (TFCRC)
Count of transmitted 10B_ERR errors
(T10BERR)
15 minute bucket index dmxPortStatCountIntervalRx
Elements dmxPortStatCountIntervalRx
Objects
The number of octets or bytes that have been received by this port. (EINB).
Note: for Fibre Channel, ordered sets are not included in the count.
The number of frames/packets that have been received by this port. (EINF)
Note: A Fibre Channel frame starts with
SOF and ends with EOF
Count of frames received with invalid
CRC (EDFE) dmxPortStatCountIntervalInv alidCRC dmxPortStatCountIntervalInv alidTxWords dmxPortStatCountIntervalLos sofSignal dmxPortStatCountIntervalLos sofSynchronization dmxPortStatCountIntervalEnc odingDisparityErrors dmxPortStatCountIntervalTx
Elements
Count of invalid transmission words received at this port (INTXWD)
Count of instances of signal loss detected at port (LOS)
Count of instances of synchronization
(LSYNC)
Count of disparity errors received at this port (DSPERR)
The number of octets or bytes that have been transmitted by this port. (EONB)
Note: for Fibre Channel, ordered sets are not included in the count.
Definition
1 to 32
15 minute
15 minute
15 minute
15 minute
15 minute
15 minute
15 minute
15 minute
B - 8 6
365-372-300
Issue 8.0 September 2006
SNMP Parameters and Traps
: Performance Monitoring
Table
dmxPortStatCountIntervalTx
Objects
Object Parameter
The number of frames/packets/ IOs/etc that have been transmitted by this port.
(EONF) Note: A Fibre Channel frame starts with SOF and ends with EOF dmxPortStatCountIntervalRx
OverflowFramesDropped dmxPortStatCountIntervalTx
OverflowFramesDropped dmxPortStatCountIntervalTx
FramesCRCErrors dmxPortStatCountIntervalTx1
0BERRErrors dmxPortStatCountDayTable
Count of received overflow frames dropped (RFOVD)
Count of transmit overflow frames dropped (TFOVD)
Count of transmitted frames with CRC errors (TFCRC)
Count of transmitted 10B_ERR errors
(T10BERR)
Definition
15 minute dmxPortStatCountDayIndex day index current or previous 24 hour period dmxPortStatCountDayRxEle ments dmxPortStatCountDayRxObj ects dmxPortStatCountDayInvalid
CRC dmxPortStatCountDayInvalid
TxWords dmxPortStatCountDayLossof
Signal dmxPortStatCountDayLossof
Synchronization dmxPortStatCountDayEncodi ngDisparityErrors
The number of octets or bytes that have been received by this port. (EINB).
Note: for Fibre Channel, ordered sets are not included in the count.
The number of frames/packets that have been received by this port. (EINF)
Note: A Fibre Channel frame starts with
SOF and ends with EOF
Count of frames received with invalid
CRC (EDFE)
Count of invalid transmission words received at this port (INTXWD)
Count of instances of signal loss detected at port (LOS)
Count of instances of synchronization
(LSYNC)
Count of disparity errors received at this port (DSPERR)
24 hour
24 hour
24 hour
24 hour
24 hour
24 hour
24 hour
365-372-300
Issue 8.0 September 2006
B - 8 7
SNMP Parameters and Traps
: Performance Monitoring
Table
dmxPortStatCountDayTxEle ments
Object Parameter
The number of octets or bytes that have been transmitted by this port. (EONB)
Note: for Fibre Channel, ordered sets are not included in the count.
dmxPortStatCountDayTxObje cts
The number of frames/packets/ IOs/etc that have been transmitted by this port.
(EONF) Note: A Fibre Channel frame starts with SOF and ends with EOF
Count of received overflow frames dropped (RFOVD) dmxPortStatCountDayRxOve rflowFramesDropped dmxPortStatCountDayTxOve rflowFramesDropped dmxPortStatCountDayTxFra mesCRCErrors
Count of transmit overflow frames dropped (TFOVD)
Count of transmitted frames with CRC errors (TFCRC)
Count of transmitted 10B_ERR errors
(T10BERR) dmxPortStatCountDayTx10B
ERRErrors dmxVcgStatCountCurrentTable dmxVcgStatCountCurrentRx
Objects dmxVcgStatCountCurrentInv alidCRC dmxVcgStatCountCurrentTx
Objects dmxVcgStatCountCurrentRx
SingleBitErrCorrectedGFP dmxVcgStatCountCurrentRx
MultiBitUncorrectedGFP dmxVcgStatCountCurrentRx
SingleBitErrCorrectedGFPSu perblk
The number of frames/packets that have been received by this port
Count of frames received with invalid
CRC (EDFE)
The number of frames/packets that have been transmitted by this port
Count of received single-bit error corrected GFP header count (RCORH).
Count of received uncorrected multi-bit error GFP header count (RCRCH).
Count of received single-bit error corrected GFP super-block count
(RCORF).
dmxVcgStatCountIntervalTable dmxVcgStatCountIntervalInd ex dmxVcgStatCountIntervalRx
Objects
15 minute bucket index
The number of frames/packets that have been received by this port
Definition
24 hour
24 hour
24 hour
24 hour
24 hour
24 hour
15 minute
15 minute
B - 8 8
365-372-300
Issue 8.0 September 2006
SNMP Parameters and Traps
: Performance Monitoring
Table Object Parameter
dmxVcgStatCountIntervalInv alidCRC
Count of frames received with invalid
CRC (EDFE) dmxVcgStatCountIntervalTx
Objects dmxVcgStatCountIntervalRx
SingleBitErrCorrectedGFP dmxVcgStatCountIntervalRx
MultiBitUncorrectedGFP dmxVcgStatCountIntervalRx
SingleBitErrCorrectedGFPSu perblk
The number of frames/packets that have been transmitted by this port
Count of received single-bit error corrected GFP header count (RCORH).
Count of received uncorrected multi-bit error GFP header count (RCRCH).
Count of received single-bit error corrected GFP super-block count
(RCORF).
dmxVcgStatCountDayTable dmxVcgStatCountDayIndex day index dmxVcgStatCountDayRxObj ects dmxVcgStatCountDayInvalid
CRC
The number of frames/packets that have been received by this port
Count of frames received with invalid
CRC (EDFE) dmxVcgStatCountDayTxObje cts dmxVcgStatCountDayRxSing leBitErrCorrectedGFP dmxVcgStatCountDayRxMul tiBitUncorrectedGFP dmxVcgStatCountDayRxSing leBitErrCorrectedGFPSuperbl k
The number of frames/packets that have been transmitted by this port
Count of received single-bit error corrected GFP header count (RCORH).
Count of received uncorrected multi-bit error GFP header count (RCRCH).
Count of received single-bit error corrected GFP super-block count
(RCORF).
Definition
15 minute
15 minute
15 minute
15 minute
15 minute
24 hour
24 hour
24 hour
24 hour
24 hour
24 hour
24 hour
Private FC/ESCON/Ficon PM MIB Module Traps
The following table shows the private Ethernet PM MIB module traps.
These traps are onlt supported on the LNW73 pack.
dmxAlarmId Parameter
dmxPortStatInc1GfcLos Loss of signal (LOS) on 1GFC port dmxPortStatInc1GfcLosClr LOS clear on 1GFC port
365-372-300
Issue 8.0 September 2006
B - 8 9
SNMP Parameters and Traps
: Performance Monitoring
dmxAlarmId Parameter
dmxPortStatInc2GfcLos Loss of signal (LOS) on 2GFC port dmxPortStatInc2GfcLosClr dmxPortStatIncEsconLos dmxPortStatIncEsconLosClr dmxPortStatIncFiconLos
LOS clear on ESCON port
Loss of signal (LOS) on 2GFC port
LOS clear on ESCON port
Loss of signal (LOS) on FICON port dmxPortStatIncFiconLosClr dmxPortStatInc1GfcLsync dmxPortStatInc1GfcLsyncClr dmxPortStatInc2GfcLsync dmxPortStatInc2GfcLsyncClr dmxPortStatIncEsconLsync dmxPortStatIncEsconLsyncClr dmxPortStatIncFiconLsync dmxPortStatIncFiconLsyncClr dmxPortStatCount1GfcTINTXWD dmxPortStatCount2GfcTINTXWD dmxPortStatCountFiconTINTXWD dmxPortStatCountEsconTINTXWD
LOS clear on FICON port inc. Loss of Synch (LSYNC) on 1GFC port
LSYNC clear on 1GFC port inc. Loss of Synch (LSYNC) on 2GFC port
LSYNC clear on ESCON port inc. Loss of Synch (LSYNC) on 2GFC port
LSYNC clear on ESCON port inc. Loss of Synch (LSYNC) on FICON port
LSYNC clear on FICON port
Invalid transmission words TCA received at this 1GFC port
Invalid transmission words TCA received at this 2GFC port
Invalid transmission words TCA received at this FICON port
Invalid transmission words TCA received at this ESCON port
Standard Ethernet interface
MIB module (RFC2863)
DMX supports the standard Ethernet interface MIB module defined in
RFC2863. This module defines Ethernet traps and retrievable Ethernet port and PM parameters. This MIB module applies to individual Fast
Ethernet and Gigabit Ethernet ports.
B - 9 0
365-372-300
Issue 8.0 September 2006
SNMP Parameters and Traps ifDescr
Object
: Performance Monitoring
Standard Ethernet interface MIB Module Parameters
The following table shows the standard Ethernet interface MIB module parameters.
Definition
Interface description (mfg, product, version) ifSpeed ifAdminStatus ifOperStatus ifLastChange ifInOctets
IfInUcastPkts ifInMulticastPkts ifInBroadcastPkts ifInErrors
Interface maximum rate (bps) - for GbE circuit pack, this is
“1,000,000,000”, for FE circuit pack, value is based on value of the line rate parameter. If the line rate is 10M, ifSpeed value is “10,000,000”. If the line rate parameter is 100M, ifSpeed value is “100,000,000”.
Administration status (up, down or testing) (read only). Value is always
“up”.
Operational status (up, down, testing, unknown, dormant, notPresent or lowerLayerDown). If board/port is removed, value is “notPresent”. If there is an existing alarm on the port, i.e., Loss of signal (LOS) or
Auto-Negotiation Mismatch (ANM) on the port, then the value is “down”, else the value is “up”.
TimeTicks since last re-initialization
Total Bytes Received
Frames Received: Broadcast Frames Received - Multicast Frames
Received
Multicast Frames Received
Broadcast Frames Received
CRC Error + Oversize Frames + Fragments + Jabber + MAC Rx Error
365-372-300
Issue 8.0 September 2006
B - 9 1
SNMP Parameters and Traps
: Performance Monitoring
Object Definition
ifOutOctets
IfOutUcastPkts ifOutMulticastPkts ifOutBroadcastPkts ifOutErrors ifName ifHCInOctets ifHCInUcastPkts ifHCInMulticastPkts ifHCInBroadcastPkts
Bytes Sent
Frames Sent - Out Multicast Frames - Out Broadcast Frames
Out Multicast Frames
Out Broadcast Frames
(always 0) (not supported in this release)
Interface name - (always set to NULL)
Total Bytes Received
Frames Received: Broadcast Frames Received - Multicast Frames
Received
Multicast Frames Received
Broadcast Frames Received
Frames Sent - Out Multicast Frames - Out Broadcast Frames ifHCOutUcastPkts ifHCOutBroadcastPkts ifLinkUpDownTrapEnable ifHighSpeed ifPromiscuousMode
Out Broadcast Frames
Traps enabled or disabled - DMX, Metropolis
®
DMXpress and
Metropolis
®
DMX supports READ-ONLY
Interface speed (Mbps) - for GbE circuit pack, this is “1,000”, for FE circuit pack, value is based on line rate parameter. If the line rate is 10M,
ifSpeed value is “10”. If the line rate is 100M, ifSpeed value is “100”.
Promiscuous mode (true or false) - DMX, DMXpress and DMXtend supports READ-ONLY ifAlias ifCounterDiscontinuity
TimeTimeStamp
Interface alias name - READ-ONLY - - (always set to NULL)
Time of last counter discontinuity
B - 9 2
365-372-300
Issue 8.0 September 2006
SNMP Parameters and Traps
: Performance Monitoring
Standard Ethernet interface MIB Module Traps
The following table shows the standard Ethernet interface MIB module traps.
Object Definition
linkUp linkDown link up link down
Standard Ethernet PM MIB module
(RFC2358/RFC2665)
DMX supports the standard Ethernet PM MIB module defined in
RFC2358 and RFC2665. This module defines additional retrievable
Ethernet PM parameters. This MIB module applies to individual Fast
Ethernet and Gigabit Ethernet ports.
Standard Ethernet PM MIB Module Parameters
The following table shows the standard Ethernet PM MIB module parameters.
Object Definition
dot3StatsAlignmentErrors dot3StatsFCSErrors dot3StatsSingleCollisionFrames dot3StatsMultipleCollisionFrames dot3StatsSQETestErrors dot3StatsDeferredTransmissions dot3StatsLateCollisions
Fragments
CRC Error
Collision
(always 0) (not supported in this release)
(always 0) (not supported in this release)
(always 0) (not supported in this release)
Late Collision dot3StatsExcessiveCollisions (always 0) (not supported in this release) dot3StatsInternalMacTransmitErrors (always 0) (not supported in this release) dot3StatsCarrierSenseErrors dot3StatsFrameTooLongs
(always 0) (not supported in this release)
Oversize Frames dot3StatsInternalMacReceiveErrors MAC Rx Error dot3StatsSymbolErrors (always 0) (not supported in this release) dot3StatsDuplex Status
Duplex Status (half duplex (2), full duplex (3) - added by
RFC2665
365-372-300
Issue 8.0 September 2006
B - 9 3
SNMP Parameters and Traps
: Performance Monitoring
Object
dot3ControlFunctionsSupported dot3ControlInUnknownOpcodes dot3PauseAdminMode dot3PauseOperMode dot3InPauseFrames dot3OutPauseFrames
Definition
pause (0) --802.3 flow control - added by RFC2665
(always 0) - added by RFC2665 (not supported in this release)
Flow control default mode (read only) - added by RFC2665
Flow control operational mode (disabled (1), enabled transmit & receive (4)) - added by RFC2665
(always 0) - added by RFC2665 (not supported in this release)
(always 0) - added by RFC2665 (not supported in this release)
Private VCG MIB module
DMX supports a private VCG MIB module for VCG traps. This private
VCG MIB module applies to individual VCGs.
Private VCG MIB Module Traps
The following table shows the private VCG MIB module traps.
Trap Object
dmxIncVcgFail dmxIncVcgFailClr dmxIncVcgGeLanTEDFC dmxIncVcgFeLanTEDFC dmxIncVcgGeLanTEDFE dmxIncVcgFeLanTEDFE dmxIncVcgGfpRcfFail dmxIncVcgGfpRcfFailClr dmxIncVcgLopcFail dmxIncVcgLopcFailClr dmxIncVcgFoprFail
Definition
Incoming VCG fail
Incoming VCG fail clear
Dropped frames due to congestion TCA on VCG
GbE WAN port
Dropped frames due to congestion TCA on VCG FE
WAN port
Dropped frames due to errors TCA on VCG GbE
WAN port
Dropped frames due to errors TCA on VCG FE WAN port
General framing procedure remote client signal failed
(GFP_RCF)
General framing procedure remote client signal failed
(GFP_RCF) clear
VCG loss of partial capacity (VCGLOPC)
VCG loss of partial capacity (VCGLOPC) clear
VCG failure of LCAS protocol (Sink) (VCGFOPR)
B - 9 4
365-372-300
Issue 8.0 September 2006
SNMP Parameters and Traps
Trap Object
dmxIncVcgFoprFailClr dmxIncVcgFoptFail dmxIncVcgFoptFailClr dmxIncVcgNOTLCAS dmxIncVcgNOTLCASClr dmxIncSts1Lom dmxIncSts1LomClr dmxIncSts3cLom dmxIncSts3cLomClr dmxIncVt1Lom dmxIncVt1LomClr dmxIncSts1Sqm dmxIncSts1SqmClr dmxIncSts3cSqmClr dmxIncVt1SqmClr dmxIncVcgSts1MSUL dmxIncVcgSts1MSULClr dmxIncVcgSts3cMSUL dmxIncVcgSts3cMSULClr dmxIncVcgVtMSUL dmxIncVcgVtMSULClr
365-372-300
Issue 8.0 September 2006
: Performance Monitoring
Definition
VCG failure of LCAS protocol (Sink) (VCGFOPR) clear
VCG failure of LCAS protocol (Source)
(VCGFOPT)
VCG failure of LCAS protocol (Source)
(VCGFOPT) clear
Far End Not LCAS (NOTLCAS)
Far End Not LCAS clear (NOTLCAS)
Incoming STS1 loss of multiframe
Incoming STS1 loss of multiframe clear
Incoming STS3C loss of multiframe
Incoming STS3C loss of multiframe clear
Incoming VT1 loss of multiframe
Incoming VT1 loss of multiframe clear
Incoming STS1 sequence number mismatch
Incoming STS1 sequence number mismatch
Incoming STS3C sequence number mismatch
Incoming Vt1 sequence number mismatch
STS1 Member Signal Unacceptable -LCAS
(MSU-L)
STS1 Member Signal Unacceptable -LCAS
(MSU-L) Clear
STS3c Member Signal Unacceptable -LCAS
(MSU-L)
STS3c Member Signal Unacceptable -LCAS
(MSU-L) Clear
VT1.5 Member Signal Unacceptable -LCAS
(MSU-L)
VT1.5 Member Signal Unacceptable -LCAS
(MSU-L) Clear
B - 9 5
SNMP Parameters and Traps
: Performance Monitoring
Private MIB module
DMX supports a private MIB module for retrieving equipment information parameters and equipment traps. This private MIB module applies to individual circuit packs.
Private MIB Module Parameters
The following table shows the private MIB module parameters.
Object
dmxCardType dmxCardAPP dmxCardSSN dmxCardCLEI dmxCardECI dmxCardSLN dmxSftwVersion dmxCardCPMode dmxCardEccMode dmxCardVlanTagMode dmxCardVtVcat dmxCardDataType
Definition
Circuit pack type.
Circuit pack apparatus code
Circuit pack series number
Common Language Equipment code
Equipment Catalog Item code
Circuit pack serial number
Version of the software currently stored in the circuit pack
Circuit pack mode. This parameter is only applicable to the
LNW26 and LNW26B circuit packs. It indicates the functional mode of the circuit pack. Values: NORMAL,
ENHANCED
Ethernet Cross-connect Mode. This mode only pertains to the LNW71 Fast Ethernet circuit pack. Values: STS1,
STS3c
Virtual LAN tagging mode. This parameter is ONLY reported for slots containing an Ethernet circuit pack.
Values: 802.1TAG (IEEE 802.1Q mode), TRANS
(Transparent mode), NOTAG (No Tag mode)
VT Virtual Concatenation. This parameter specifies the number of STS-1s dedicated to VT virtual concatenation.
Data type. Values are:
FC-FICON - in this mode, data ports are configured individually for Fibre Channel or FICON.
ESCON - in this mode all ports on the circuit pack are set for ESCON
This object applies only to the LNW73 circuit pack
B - 9 6
365-372-300
Issue 8.0 September 2006
SNMP Parameters and Traps
: Performance Monitoring
Private MIB Module Traps
The following table shows the private MIB module traps.
Object Definition
dmxCpNotAllowed Circuit pack not allowed dmxCpNotAllowedClr Circuit pack not allowed clear dmxFACTERM dmxFACTERMClr dmxFETERM dmxFETERMClr
Illegal circuit pack type
Illegal circuit pack type clear
FE-LAN circuit pack failed
FE-LAN circuit pack failed clear dmxGETERM dmxGETERMClr dmxCpRemoved dmxCpRemovedClr dmxCpInserted
GE-LAN circuit pack failed
GE-LAN circuit pack failed clear
Circuit pack removed
Circuit pack removed clear
Circuit pack inserted
365-372-300
Issue 8.0 September 2006
B - 9 7
SNMP Parameters and Traps
: Performance Monitoring
RPR IEEE Draft
P802.17/D3.3 MIB tables supported
The RPR IEEE Draft P802.17/D3.3 MIB shall be supported for retrieving RPR information and RPR PM counters only. Provisioning of RPR parameters and objects through SNMP shall not be supported.
Span tables
Running counters tables
(Continuous counter paradigm)
Basic tables
Protocol tables
Standard RPR MIB tables supported
Starting in Release 6.0/4.0, DMX/DMXtend shall support the RPR
IEEE Draft P802.17/D3.3 MIB tables as follows:.
rprSpanTable rprSpanProtectionTable rprSpanCountersStatsTable rprClientCountersStatsTable rprSpanErrorCountersStatsTable rprIfTable rprTopoImageTable rprFairnessTable partially supported partially supported
Fully Supported
Fully Supported partially supported partially supported partially supported partially supported
B - 9 8
365-372-300
Issue 8.0 September 2006
SNMP Parameters and Traps
: Performance Monitoring
RPR IEEE Draft P802.17/D3.3
MIB objects supported
Starting in Release 6.0/4.0, DMX and DMXtend shall support the RPR
IEEE Draft P802.17/D3.3 MIB objects as specified in the following 6 tables.
RPR Basic Tables
Definition Value
rprIfTable rprIfIndex
Table/Object
rprIfStationsOnRing rprIfReversionMode rprIfProtectionWTR rprIfProtectionFastTimer rprIfProtectionSlowTimer rprIfAtdTimer rprIfKeepaliveTimeout rprIfFairnessAggressive rprIfPtqSize rprIfStqSize rprIfSTQFullThreshold rprIfIdleThreshold rprIfSesThreshold rprIfWrapConfig rprIfJumboFramePreferred rprIfMacOperModes rprIfRingOperModes rprIfCurrentStatus rprIfLastChange
InterfaceIndex
Unsigned32
TruthValue
Unsigned32
Unsigned32
Unsigned32
Unsigned32
Unsigned32
TruthValue
Unsigned32
Unsigned32
Unsigned32
Unsigned32
Unsigned32
TruthValue
TruthValue
BITS
BITS
BITS
TimeStamp
Always “TRUE”
Always “TRUE” not supported, always 0 not supported, always 0 not supported, always 0 bit 0: strictOrder always 0 bit 1: dropBadFcs always 1 not supported, always 0
365-372-300
Issue 8.0 September 2006
B - 9 9
SNMP Parameters and Traps
RPR Span Tables
Table/Object
rprSpanTable
Definition
rprSpanIfIndex rprSpanId
InterfaceIndex rprSpan rprSpanLowerLayerIfIndex InterfaceIndexOrZero rprSpanTotalRingletReservedRate Unsigned32 rprSpanCurrentStatus rprSpanLastChange rprSpanChanges rprSpanProtectionTable rprSpanProtectionIfIndex rprSpanProtectionSpan rprSpanProtectionNeighborValid rprSpanProtectionHoldOffTimer rprSpanProtectionCommand rprSpanProtectionCount rprSpanProtectionDuration rprSpanProtectionLastActivationTi me
BITS
TimeStamp
Counter32
InterfaceIndex rprSpan
TruthValue
Unsigned32
INTEGER
Counter32
Counter32
TimeStamp
RPR Protocol Tables
Table/Object
rprTopoImageTable rprTopoImageIfIndex rprTopoImageMacAddress rprTopoImageSecMacAddress1
Definition
InterfaceIndex
MacAddress
MacAddress
B - 1 0 0
: Performance Monitoring
Value
not supported, always 0 not supported, always 0 not supported, always 0 not supported, always 0 not supported, always 0 not supported, always 0
Value
not supported, always
“FF:FF:FF:FF:FF:FF"
365-372-300
Issue 8.0 September 2006
SNMP Parameters and Traps
Table/Object
rprTopoImageSecMacAddress2 rprTopoImageStationIfIndex rprTopoImageStationName rprTopoImageInetAddressType rprTopoImageInetAddress
Definition
MacAddress
InterfaceIndex
SnmpAdminString
InetAddressType
InetAddress rprTopoImageCapability BITS rprTopoImageRinglet0Hops rprTopoImageRinglet0ReservedRa te rprTopoImageRinglet1Hops
Integer32
Unsigned32
Integer32 rprTopoImageRinglet1ReservedRa te rprTopoImageWestProtectionStatu s
Unsigned32 rprProtectionStatus rprTopoImageWestWeight Unsigned32 rprTopoImageEastProtectionStatus rprProtectionStatus rprTopoImageEastWeight Unsigned32
BITS rprTopoImageStatus rprFairnessTable rprFairnessIfIndex rprFairnessRinglet rprFairnessRingletWeight rprFairnessReservedRate rprFairnessMaxAllowed
365-372-300
Issue 8.0 September 2006
InterfaceIndex
INTEGER
Unsigned32
Unsigned32
Unsigned32
: Performance Monitoring
Value
not supported, always
“FF:FF:FF:FF:FF:FF" not supported, always 0 not supported, always 0 not supported, always “unknown” not supported, always 0 bit0 (jumboFrames) set according to
RTRV-MAP-RPR
:jumbo. If
jumbo=YES, then bit0=1, else bit0=0. All other bits=0.
not supported, always 0 not supported, always 0 bit0 (reachableRinglet0) and bit1
(reachableRinglet1) set according to
RTRV-MAP-RPR
:r0hops and
r1hops. If r0hops/r1hops=-1, then bit0/bit1 =0, else bit0/bit1 =1. All other bits=0.
not supported, always 0
B - 1 0 1
SNMP Parameters and Traps
Table/Object
rprFairnessAgeCoef rprFairnessRampCoef rprFairnessLpCoef rprFairnessAdvertisementRatio rprFairnessMcffReportCoef rprFairnessActiveWeightsCoef rprFairnessSTQHighThreshold rprFairnessSTQMedThreshold rprFairnessSTQLowThreshold rprFairnessRateHighThreshold rprFairnessRateLowThreshold rprFairnessResetWaterMarks rprFairnessSTQHighWaterMark rprFairnessSTQLowWaterMark rprFairnessLastChange rprFairnessChanges
Unsigned32
Definition
Unsigned32
Unsigned32
Unsigned32
Unsigned32
Unsigned32
Unsigned32
Unsigned32
Unsigned32
Unsigned32
Unsigned32
INTEGER
Unsigned32
Unsigned32
TimeStamp
Counter32
: Performance Monitoring
Value
not supported, always 0 not supported, always 0 not supported, always 0 not supported, always 0 not supported, always 0 not supported, always 0 not supported, always 0 not supported, always 0 not supported, always 0 not supported, always 0
B - 1 0 2
365-372-300
Issue 8.0 September 2006
SNMP Parameters and Traps
365-372-300
Issue 8.0 September 2006
: Performance Monitoring
RPR Span Counters Tables
Table/Object
rprSpanCountersStatsTable rprSpanStatsIfIndex
Definition
InterfaceIndex rprSpanStatsSpan rprSpan rprSpanStatsInUcastClassAFrames Counter64 rprSpanStatsInUcastClassAOctets Counter64 rprSpanStatsInUcastClassBCirFram es
Counter64 rprSpanStatsInUcastClassBCirOcte ts rprSpanStatsInUcastClassBEirFram es
Counter64
Counter64 rprSpanStatsInUcastClassBEirOctet s
Counter64 rprSpanStatsInUcastClassCFrames Counter64 rprSpanStatsInUcastClassCOctets Counter64 rprSpanStatsInMcastClassAFrames Counter64 rprSpanStatsInMcastClassAOctets Counter64 rprSpanStatsInMcastClassBCirFra mes
Counter64 rprSpanStatsInMcastClassBCirOcte ts rprSpanStatsInMcastClassBEirFra mes
Counter64
Counter64 rprSpanStatsInMcastClassBEirOcte ts
Counter64 rprSpanStatsInMcastClassCFrames Counter64 rprSpanStatsInMcastClassCOctets Counter64 rprSpanStatsInCtrlFrames Counter64 rprSpanStatsInOamEchoFrames Counter64 - not supported, always 0
B - 1 0 3
SNMP Parameters and Traps
: Performance Monitoring
Table/Object
rprSpanStatsInOamFlushFrames
Definition
Counter64 - not supported, always 0 rprSpanStatsInOamOrgFrames rprSpanStatsInTopoAtdFrames rprSpanStatsInTopoChkSumFrame s rprSpanStatsInTopoTpFrames
Counter64 - not supported, always 0
Counter64
Counter64
Counter64 rprSpanStatsOutUcastClassAFrame s
Counter64 rprSpanStatsOutUcastClassAOctets Counter64 rprSpanStatsOutUcastClassBCirFra mes rprSpanStatsOutUcastClassBCirOct ets rprSpanStatsOutUcastClassBEirFra mes rprSpanStatsOutUcastClassBEirOct ets
Counter64
Counter64
Counter64
Counter64 rprSpanStatsOutUcastClassCFrame s
Counter64 rprSpanStatsOutUcastClassCOctets Counter64 rprSpanStatsOutMcastClassAFram es rprSpanStatsOutMcastClassAOctet s
Counter64
Counter64 rprSpanStatsOutMcastClassBCirFr ames rprSpanStatsOutMcastClassBCirOc tets rprSpanStatsOutMcastClassBEirFra mes rprSpanStatsOutMcastClassBEirOc tets
Counter64
Counter64
Counter64
Counter64
B - 1 0 4
365-372-300
Issue 8.0 September 2006
SNMP Parameters and Traps
: Performance Monitoring
Table/Object
rprSpanStatsOutMcastClassCFrame s rprSpanStatsOutOamOrgFrames rprSpanStatsOutTopoAtdFrames rprSpanStatsOutTopoChkSumFram es rprSpanStatsOutTopoTpFrames
Counter64
Counter64
Counter64
Definition
rprSpanStatsOutMcastClassCOctets Counter64 rprSpanStatsOutCtrlFrames Counter64 rprSpanStatsOutOamEchoFrames Counter64 - not supported, always 0 rprSpanStatsOutOamFlushFrames Counter64 - not supported, always 0
Counter64 - not supported, always 0
Counter64
RPR Client Counters Tables
365-372-300
Issue 8.0 September 2006
Table/Object
rprClientCountersStatsTable rprClientStatsIfIndex
Definition
rprClientStatsInUcastClassAFrames rprClientStatsInUcastClassAOctets
InterfaceIndex
Counter64
Counter64 rprClientStatsInUcastClassBCirFrame s
Counter64 rprClientStatsInUcastClassBCirOctets Counter64 rprClientStatsInUcastClassBEirFrame s
Counter64 rprClientStatsInUcastClassBEirOctets Counter64 rprClientStatsInUcastClassCFrames rprClientStatsInUcastClassCOctets rprClientStatsInMcastClassAFrames rprClientStatsInMcastClassAOctets rprClientStatsInMcastClassBCirFram es
Counter64
Counter64
Counter64
Counter64
Counter64
B - 1 0 5
SNMP Parameters and Traps
: Performance Monitoring
Table/Object
rprClientStatsInMcastClassBCirOctet s
Counter64 rprClientStatsInMcastClassBEirFrame s
Counter64 rprClientStatsInMcastClassBEirOctets Counter64 rprClientStatsInMcastClassCFrames rprClientStatsInMcastClassCOctets
Counter64
Counter64 rprClientStatsInBcastFrames Counter64 rprClientStatsOutUcastClassAFrames Counter64 rprClientStatsOutUcastClassAOctets Counter64 rprClientStatsOutUcastClassBCirFra mes
Counter64 rprClientStatsOutUcastClassBCirOcte ts rprClientStatsOutUcastClassBEirFra mes
Counter64
Counter64 rprClientStatsOutUcastClassBEirOcte ts
Counter64 rprClientStatsOutUcastClassCFrames Counter64 rprClientStatsOutUcastClassCOctets Counter64 rprClientStatsOutMcastClassAFrames Counter64 rprClientStatsOutMcastClassAOctets Counter64 rprClientStatsOutMcastClassBCirFra mes
Counter64 rprClientStatsOutMcastClassBCirOct ets rprClientStatsOutMcastClassBEirFra mes
Counter64
Counter64 rprClientStatsOutMcastClassBEirOcte ts
Counter64 rprClientStatsOutMcastClassCFrames Counter64
Definition
B - 1 0 6
365-372-300
Issue 8.0 September 2006
SNMP Parameters and Traps
: Performance Monitoring
Table/Object
rprClientStatsOutMcastClassCOctets Counter64 rprClientStatsOutBcastFrames Counter64
Definition
RPR Span Errors CountersTables
Table/Object
rprSpanErrorCountersStatsTable
Definition
rprSpanErrorStatsIfIndex rprSpanErrorStatsSpan
InterfaceIndex rprSpan rprSpanErrorStatsTtlExpFrames Counter64 rprSpanErrorStatsTooLongFrames Counter64 rprSpanErrorStatsTooShortFrames Counter64 rprSpanErrorStatsBadHecFrames Counter64 rprSpanErrorStatsBadFcsFrames Counter64 rprSpanErrorStatsSelfSrcUcastFra mes
Counter64 rprSpanErrorStatsPmdAbortFrame s
Counter64 rprSpanErrorStatsBadAddrFrames Counter64 rprSpanErrorStatsBadParityFrame s rprSpanErrorStatsContainedFrame s rprSpanErrorStatsScffErrors
Counter64
Counter64
Counter64
)
Value
not supported, always 0
(included in rprSpanErrorStatsBadFcsFrames)
(includes rprSpanErrorStatsTooShortFrames not supported, always 0 not supported, always 0
365-372-300
Issue 8.0 September 2006
B - 1 0 7
SNMP Parameters and Traps
: Performance Monitoring
Private RPR LAN PM counters
MIB
Starting in Release 6.0/4.0, DMX/DMXtend shall support the DMX
RPR PM Counters tables for LAN and VCG Ports, as specified in the table below
DMX Private RPR Counters Table
Table
dmxRprCurrentEntry
Object
dmxRprCurrentIndex dmxRprCurrentIUCAF dmxRprCurrentIUCAO dmxRprCurrentIUCBF dmxRprCurrentIUCBO dmxRprCurrentIUCBEF dmxRprCurrentIUCBEO dmxRprCurrentIUCCF dmxRprCurrentIUCCO dmxRprCurrentIMCAF
Description
Current index
Number of Class A unicast frames received with no errors- current
Number of Class A unicast octets received with no errors- current
Number of Class B unicast frames received below CIR with no errors- current
Number of Class B unicast octets received below CIR with no errors- current
Number of Class B unicast frames received below EIR with no errors- current
Number of Class B unicast octets received below EIR with no errors- current
Number of Class C unicast frames received with no errors- current
Number of Class C unicast octets received with no error- current
Number of Class A multicast frames received with no error- current
Application
Valid for LAN and
RPR IF VCG ports
Valid for LAN and
RPR IF VCG ports
Valid for LAN and
RPR IF VCG ports
Valid for LAN and
RPR IF VCG ports
Valid for LAN and
RPR IF VCG ports
Valid for LAN and
RPR IF VCG ports
Valid for LAN and
RPR IF VCG ports
Valid for LAN and
RPR IF VCG ports
Valid for LAN and
RPR IF VCG ports
B - 1 0 8
365-372-300
Issue 8.0 September 2006
SNMP Parameters and Traps
Table
365-372-300
Issue 8.0 September 2006
: Performance Monitoring
Object
dmxRprCurrentIMCAO dmxRprCurrentIMCBF dmxRprCurrentIMCBO dmxRprCurrentIMCBEF dmxRprCurrentIMCBEO dmxRprCurrentIMCCF dmxRprCurrentIMCCO dmxRprCurrentOUCAF dmxRprCurrentOUCAO dmxRprCurrentOUCBF dmxRprCurrentOUCBO
Description
Number of Class A multicast octets received with no error- current
Number of Class B multicast frames received below CIR with no error- current
Number of Class B multicast octets received below CIR with no error- current
Number of Class B multicast frames received below EIR with no error- current
Number of Class B multicast octets received below EIR with no error- current
Number of Class C multicast frames received with no error- current
Number of Class C multicast octets received with no error- current
Number of Class A unicast frames transmitted with no errors- current
Number of Class A unicast octets transmitted with no errors- current
Number of Class B unicast frames transmitted below
CIR with no errors- current
Number of Class B unicast octets transmitted below
CIR with no errors- current
Application
Valid for LAN and
RPR IF VCG ports
Valid for LAN and
RPR IF VCG ports
Valid for LAN and
RPR IF VCG ports
Valid for LAN and
RPR IF VCG ports
Valid for LAN and
RPR IF VCG ports
Valid for LAN and
RPR IF VCG ports
Valid for LAN and
RPR IF VCG ports
Valid for LAN and
RPR IF VCG ports
Valid for LAN and
RPR IF VCG ports
Valid for LAN and
RPR IF VCG ports
Valid for LAN and
RPR IF VCG ports
B - 1 0 9
SNMP Parameters and Traps
Table
: Performance Monitoring
Object
dmxRprCurrentOUCBEF dmxRprCurrentOUCBEO dmxRprCurrentOUCCF dmxRprCurrentOUCCO dmxRprCurrentOMCAF dmxRprCurrentOMCAO dmxRprCurrentOMCBF dmxRprCurrentOMCBO dmxRprCurrentOMCBEF dmxRprCurrentOMCBEO
Description
Number of Class B unicast frames transmitted below
EIR with no errors- current
Number of Class B unicast octets transmitted below
EIR with no errors- current
Number of Class C unicast frames transmitted with no errors- current
Number of Class C unicast octets transmitted with no error- current
Number of Class A multicast frames transmitted with no error- current
Application
Valid for LAN and
RPR IF VCG ports
Valid for LAN and
RPR IF VCG ports
Valid for LAN and
RPR IF VCG ports
Valid for LAN and
RPR IF VCG ports
Valid for LAN and
RPR IF VCG ports
Number of Class A multicast octets transmitted with no error- current
Number of Class B multicast frames transmitted below CIR with no error- current
Valid for LAN and
RPR IF VCG ports
Valid for LAN and
RPR IF VCG ports
Number of Class B multicast octets transmitted below CIR with no error- current
Number of Class B multicast frames transmitted below EIR, no error- current
Number of Class B multicast octets transmitted below EIR with no error- current
Valid for LAN and
RPR IF VCG ports
Valid for LAN and
RPR IF VCG ports
Valid for LAN and
RPR IF VCG ports
B - 1 1 0
365-372-300
Issue 8.0 September 2006
SNMP Parameters and Traps
Table
365-372-300
Issue 8.0 September 2006
: Performance Monitoring
dmxRprCurrentSpanIUCA
F dmxRprCurrentSpanIUCA
O dmxRprCurrentSpanIUCB
F dmxRprCurrentSpanIUCB
O dmxRprCurrentSpanIUCB
EF dmxRprCurrentSpanIUCB
EO dmxRprCurrentSpanIUCC
F dmxRprCurrentSpanIUCC
O
Object
dmxRprCurrentOMCCF dmxRprCurrentOMCCO dmxRprCurrentSpanIMCA
F dmxRprCurrentSpanIMCA
O
Description
Number of Class C multicast frames transmitted with no error- current
Number of Class C multicast octets transmitted with no error- current
Number of Class A unicast frames received with no errors- CurrentSpan
Number of Class A unicast octets received with no errors- CurrentSpan
Number of Class B unicast frames received below CIR with no errors- CurrentSpan
Number of Class B unicast octets received below CIR with no errors- CurrentSpan
Number of Class B unicast frames received below EIR with no errors- CurrentSpan
Number of Class B unicast octets received below EIR with no errors- CurrentSpan
Number of Class C unicast frames received with no errors- CurrentSpan
Number of Class C unicast octets received with no error- CurrentSpan
Number of Class A multicast frames received with no error- CurrentSpan
Number of Class A multicast octets received with no error- CurrentSpan
Application
Valid for LAN and
RPR IF VCG ports
Valid for LAN and
RPR IF VCG ports
Valid for RPR Span
VCG ports
Valid for RPR Span
VCG ports
Valid for RPR Span
VCG ports
Valid for RPR Span
VCG ports
Valid for RPR Span
VCG ports
Valid for RPR Span
VCG ports
Valid for RPR Span
VCG ports
Valid for RPR Span
VCG ports
Valid for RPR Span
VCG ports
Valid for RPR Span
VCG ports
B - 1 1 1
SNMP Parameters and Traps
Table
: Performance Monitoring
dmxRprCurrentSpanIMCB
F dmxRprCurrentSpanIMCB
O dmxRprCurrentSpanIMCB
EF dmxRprCurrentSpanIMCB
EO dmxRprCurrentSpanIMCC
F dmxRprCurrentSpanIMCC
O dmxRprCurrentSpanOUC
AF dmxRprCurrentSpanOUC
AO
Object
dmxRprCurrentSpanOUCB
F dmxRprCurrentSpanOUCB
O
Description
Number of Class B multicast frames received below CIR with no error-
CurrentSpan
Number of Class B multicast octets received below CIR with no error-
CurrentSpan
Number of Class B multicast frames received below EIR with no error-
CurrentSpan
Number of Class B multicast octets received below EIR with no error-
CurrentSpan
Number of Class C multicast frames received with no error- CurrentSpan
Number of Class C multicast octets received with no error- CurrentSpan
Number of Class A unicast frames transmitted with no errors- CurrentSpan
Number of Class A unicast octets transmitted with no errors- CurrentSpan
Number of Class B unicast frames transmitted below
CIR with no errors-
CurrentSpan
Number of Class B unicast octets transmitted below
CIR with no errors-
CurrentSpan
Application
Valid for RPR Span
VCG ports
Valid for RPR Span
VCG ports
Valid for RPR Span
VCG ports
Valid for RPR Span
VCG ports
Valid for RPR Span
VCG ports
Valid for RPR Span
VCG ports
Valid for RPR Span
VCG ports
Valid for RPR Span
VCG ports
Valid for RPR Span
VCG ports
Valid for RPR Span
VCG ports
B - 1 1 2
365-372-300
Issue 8.0 September 2006
SNMP Parameters and Traps
Table
: Performance Monitoring
dmxRprCurrentSpanOMC
AF dmxRprCurrentSpanOMC
AO dmxRprCurrentSpanOMC
BF dmxRprCurrentSpanOMC
BO dmxRprCurrentSpanOMC
BEF dmxRprCurrentSpanOMC
BEO
Object
dmxRprCurrentSpanOUCB
EF dmxRprCurrentSpanOUCB
EO dmxRprCurrentSpanOUCC
F dmxRprCurrentSpanOUCC
O
Description
Number of Class B unicast frames transmitted below
EIR with no errors-
CurrentSpan
Number of Class B unicast octets transmitted below
EIR with no errors-
CurrentSpan
Number of Class C unicast frames transmitted with no errors- CurrentSpan
Number of Class C unicast octets transmitted with no error- CurrentSpan
Number of Class A multicast frames transmitted with no error-
CurrentSpan
Application
Valid for RPR Span
VCG ports
Valid for RPR Span
VCG ports
Valid for RPR Span
VCG ports
Valid for RPR Span
VCG ports
Valid for RPR Span
VCG ports
Number of Class A multicast octets transmitted with no error- CurrentSpan
Number of Class B multicast frames transmitted below CIR with no error- CurrentSpan
Valid for RPR Span
VCG ports
Valid for RPR Span
VCG ports
Number of Class B multicast octets transmitted below CIR with no error-
CurrentSpan
Number of Class B multicast frames transmitted below EIR, no error- CurrentSpan
Number of Class B multicast octets transmitted below EIR with no error-
CurrentSpan
Valid for RPR Span
VCG ports
Valid for RPR Span
VCG ports
Valid for RPR Span
VCG ports
365-372-300
Issue 8.0 September 2006
B - 1 1 3
SNMP Parameters and Traps
Table
: Performance Monitoring
dmxRprCurrentSpanOMC
CF dmxRprCurrentSpanOMC
CO
Object
dmxRprCurrentDRATEF dmxRprCurrentDTAGF dmxRprCurrentDSPIF dmxRprCurrentDSIZEF dmxRprCurrentDNOTAGF dmxRprCurrentDSMACF dmxRprCurrentDSMACO
Description
Number of Class C multicast frames transmitted with no error-
CurrentSpan
Number of Class C multicast octets transmitted with no error- CurrentSpan
Application
Valid for RPR Span
VCG ports
Valid for RPR Span
VCG ports
Multicast and broadcast packets dropped due to exceeding port rate- current
Packets dropped due to
VLAN filtering- current
Packets dropped due to internal error (SPI4)- current
Bridge counters valid for LAN, RPR IF VCG
(not RPR Span VCG) port
Bridge counters valid for LAN, RPR IF VCG
(not RPR Span VCG) port
Bridge counters valid for LAN, RPR IF VCG
(not RPR Span VCG) port
Packets dropped due to being greater then configured maximum frame size for port- current
Packets dropped due to no tag when required- current
Bridge counters valid for LAN, RPR IF VCG
(not RPR Span VCG) port
Bridge counters valid for LAN, RPR IF VCG
(not RPR Span VCG) port
Number of packets dropped due to MAC table source address filtering- current
Number of octets dropped due to MAC table source address filtering- current
Bridge counters valid for LAN, RPR IF VCG
(not RPR Span VCG) port
Bridge counters valid for LAN, RPR IF VCG
(not RPR Span VCG) port
B - 1 1 4
365-372-300
Issue 8.0 September 2006
SNMP Parameters and Traps
Table
: Performance Monitoring
dmxRprCurrentIUCARED
F dmxRprCurrentIUCARED
O dmxRprCurrentIUCBRED
F dmxRprCurrentIUCBRED
O dmxRprCurrentIUCCRED
F dmxRprCurrentIUCCRED
O
Object
dmxRprCurrentDFCG dmxRprCurrentDFCY dmxRprCurrentIMCARED
F
Description
Green packets dropped due to congestion- current
Yellow packets dropped due to congestion- current
Application
Bridge counters valid for LAN, RPR Span
VCG (not RPR IF
VCG) ports
Bridge counters valid for LAN, RPR Span
VCG (not RPR IF
VCG) ports
Number of Unicast packets assigned to Class A and given drop precedence of red- current
Number of Unicast octets assigned to Class A and given drop precedence of red- current
Number of Unicast packets assigned to Class B and given drop precedence of red- current
Metering counters valid for LAN ports only
Metering counters valid for LAN ports only
Metering counters valid for LAN ports only
Number of Unicast octets assigned to Class B and given drop precedence of red- current
Number of Unicast packets assigned to Class C and given drop precedence of red- current
Number of Multicast octets assigned to Class C and given drop precedence of red- current
Number of Multicast packets assigned to Class A and given drop precedence of red- current
Metering counters valid for LAN ports only
Metering counters valid for LAN ports only
Metering counters valid for LAN ports only
Metering counters valid for LAN ports only
365-372-300
Issue 8.0 September 2006
B - 1 1 5
SNMP Parameters and Traps
Table
: Performance Monitoring
dmxRprCurrentIMCBRED
F dmxRprCurrentIMCBRED
O dmxRprCurrentIMCCRED
F dmxRprCurrentIMCCRED
O
Object
dmxRprCurrentIMCARED
O dmxRprCurrentICTRF dmxRprCurrentIATDF dmxRprCurrentITPF dmxRprCurrentOCTRLF dmxRprCurrentOATDF dmxRprCurrentOTPF dmxRprCurrentITTLF
Description
Number of Multicast octets assigned to Class A and given drop precedence of red- current
Application
Metering counters valid for LAN ports only
Number of Multicast packets assigned to Class B and given drop precedence of red- current
Number of Multicast octets assigned to Class B and given drop precedence of red- current
Metering counters valid for LAN ports only
Metering counters valid for LAN ports only
Number of Multicast packets assigned to Class C and given drop precedence of red- current
Number of Multicast octets assigned to Class C and given drop precedence of red- current
Metering counters valid for LAN ports only
Metering counters valid for LAN ports only
Number of control frames received- current
Number of ATD frames received- current
Number of TP frames received- current
Number of control frames transmitted- current
Number of ATD frames transmitted- current
Number of TP frames transmitted- current
Number of frames received with expired TTL values- current
Span counters valid for
RPR Span VCG only
Span counters valid for
RPR Span VCG only
Span counters valid for
RPR Span VCG only
Span counters valid for
RPR Span VCG only
Span counters valid for
RPR Span VCG only
Span counters valid for
RPR Span VCG only
Span counters valid for
RPR Span VCG only
B - 1 1 6
365-372-300
Issue 8.0 September 2006
SNMP Parameters and Traps
: Performance Monitoring
Table
dmxRprIntervalEntry
Object
dmxRprCurrentDLONG dmxRprCurrentDHEC dmxRprCurrentDSS dmxRprCurrentDSA dmxRprCurrentDPTY dmxRprCurrentDSCFF dmxRprIntervalIndex dmxRprIntervalIUCAF dmxRprIntervalIUCAO dmxRprIntervalIUCBF dmxRprIntervalIUCBO dmxRprIntervalIUCBEF
Description
Number of frames received with length exceeding the max allowed length- current
Application
Span counters valid for
RPR Span VCG only
Number of frames received with HEC value not matching the expected HEC value- current
Number of frames received sourced by this station and then received by this station- current
Span counters valid for
RPR Span VCG only
Span counters valid for
RPR Span VCG only
Number of frames received with bad SA (Multicast or
Broadcast)- current
Number of frames received with Parity value not matching the expected
Parity value- current
Number of SCFF frames received with bad FCS or bad parity- current
15 minute index
Number of Class A unicast frames received with no errors- 15 minute
Number of Class A unicast octets received with no errors- 15 minute
Number of Class B unicast frames received below CIR with no errors- 15 minute
Number of Class B unicast octets received below CIR with no errors- 15 minute
Number of Class B unicast frames received below EIR with no errors- 15 minute
Span counters valid for
RPR Span VCG only
Span counters valid for
RPR Span VCG only
Span counters valid for
RPR Span VCG only
Valid for LAN and
RPR IF VCG ports
Valid for LAN and
RPR IF VCG ports
Valid for LAN and
RPR IF VCG ports
Valid for LAN and
RPR IF VCG ports
Valid for LAN and
RPR IF VCG ports
365-372-300
Issue 8.0 September 2006
B - 1 1 7
SNMP Parameters and Traps
Table
B - 1 1 8
: Performance Monitoring
Object
dmxRprIntervalIUCBEO dmxRprIntervalIUCCF dmxRprIntervalIUCCO dmxRprIntervalIMCAF dmxRprIntervalIMCAO dmxRprIntervalIMCBF dmxRprIntervalIMCBO dmxRprIntervalIMCBEF dmxRprIntervalIMCBEO dmxRprIntervalIMCCF dmxRprIntervalIMCCO
Description
Number of Class B unicast octets received below EIR with no errors- 15 minute
Number of Class C unicast frames received with no errors- 15 minute
Number of Class C unicast octets received with no error- 15 minute
Number of Class A multicast frames received with no error- 15 minute
Number of Class A multicast octets received with no error- 15 minute
Application
Valid for LAN and
RPR IF VCG ports
Valid for LAN and
RPR IF VCG ports
Valid for LAN and
RPR IF VCG ports
Valid for LAN and
RPR IF VCG ports
Valid for LAN and
RPR IF VCG ports
Number of Class B multicast frames received below CIR with no error- 15 minute
Number of Class B multicast octets received below CIR with no error- 15 minute
Valid for LAN and
RPR IF VCG ports
Valid for LAN and
RPR IF VCG ports
Number of Class B multicast frames received below EIR with no error- 15 minute
Number of Class B multicast octets received below EIR with no error- 15 minute
Valid for LAN and
RPR IF VCG ports
Valid for LAN and
RPR IF VCG ports
Number of Class C multicast frames received with no error- 15 minute
Number of Class C multicast octets received with no error- 15 minute
Valid for LAN and
RPR IF VCG ports
Valid for LAN and
RPR IF VCG ports
365-372-300
Issue 8.0 September 2006
SNMP Parameters and Traps
Table
: Performance Monitoring
Object
dmxRprIntervalOUCAF dmxRprIntervalOUCAO dmxRprIntervalOUCBF dmxRprIntervalOUCBO dmxRprIntervalOUCBEF dmxRprIntervalOUCBEO dmxRprIntervalOUCCF dmxRprIntervalOUCCO dmxRprIntervalOMCAF dmxRprIntervalOMCAO
Description
Number of Class A unicast frames transmitted with no errors- 15 minute
Number of Class A unicast octets transmitted with no errors- 15 minute
Number of Class B unicast frames transmitted below
CIR with no errors- 15 minute
Number of Class B unicast octets transmitted below
CIR with no errors- 15 minute
Number of Class B unicast frames transmitted below
EIR with no errors- 15 minute
Number of Class B unicast octets transmitted below
EIR with no errors- 15 minute
Number of Class C unicast frames transmitted with no errors- 15 minute
Number of Class C unicast octets transmitted with no error- 15 minute
Number of Class A multicast frames transmitted with no error-
15 minute
Number of Class A multicast octets transmitted with no error- 15 minute
Application
Valid for LAN and
RPR IF VCG ports
Valid for LAN and
RPR IF VCG ports
Valid for LAN and
RPR IF VCG ports
Valid for LAN and
RPR IF VCG ports
Valid for LAN and
RPR IF VCG ports
Valid for LAN and
RPR IF VCG ports
Valid for LAN and
RPR IF VCG ports
Valid for LAN and
RPR IF VCG ports
Valid for LAN and
RPR IF VCG ports
Valid for LAN and
RPR IF VCG ports
365-372-300
Issue 8.0 September 2006
B - 1 1 9
SNMP Parameters and Traps
Table
B - 1 2 0
: Performance Monitoring
Object
dmxRprIntervalOMCBF dmxRprIntervalOMCBO dmxRprIntervalOMCBEF dmxRprIntervalOMCBEO dmxRprIntervalOMCCF dmxRprIntervalOMCCO dmxRprIntervalSpanIUCA
F dmxRprIntervalSpanIUCA
O dmxRprIntervalSpanIUCB
F dmxRprIntervalSpanIUCB
O dmxRprIntervalSpanIUCB
EF
Description
Number of Class B multicast frames transmitted below CIR with no error- 15 minute
Application
Valid for LAN and
RPR IF VCG ports
Number of Class B multicast octets transmitted below CIR with no error- 15 minute
Number of Class B multicast frames transmitted below EIR, no error- 15 minute
Valid for LAN and
RPR IF VCG ports
Valid for LAN and
RPR IF VCG ports
Number of Class B multicast octets transmitted below EIR with no error- 15 minute
Number of Class C multicast frames transmitted with no error-
15 minute
Valid for LAN and
RPR IF VCG ports
Valid for LAN and
RPR IF VCG ports
Number of Class C multicast octets transmitted with no error- 15 minute
Number of Class A unicast frames received with no errors- 15 minute
Number of Class A unicast octets received with no errors- 15 minute
Number of Class B unicast frames received below CIR with no errors- 15 minute
Number of Class B unicast octets received below CIR with no errors- 15 minute
Number of Class B unicast frames received below EIR with no errors- 15 minute
Valid for LAN and
RPR IF VCG ports
Valid for RPR Span
VCG ports
Valid for RPR Span
VCG ports
Valid for RPR Span
VCG ports
Valid for RPR Span
VCG ports
Valid for RPR Span
VCG ports
365-372-300
Issue 8.0 September 2006
SNMP Parameters and Traps
Table
365-372-300
Issue 8.0 September 2006
: Performance Monitoring
dmxRprIntervalSpanIUCB
EO dmxRprIntervalSpanIUCC
F dmxRprIntervalSpanIUCC
O dmxRprIntervalSpanIMCB
F dmxRprIntervalSpanIMCB
O dmxRprIntervalSpanIMCB
EF dmxRprIntervalSpanIMCB
EO dmxRprIntervalSpanIMCC
F dmxRprIntervalSpanIMCC
O
Object
dmxRprIntervalSpanIMCA
F dmxRprIntervalSpanIMCA
O
Description
Number of Class B unicast octets received below EIR with no errors- 15 minute
Number of Class C unicast frames received with no errors- 15 minute
Number of Class C unicast octets received with no error- 15 minute
Number of Class A multicast frames received with no error- 15 minute
Number of Class A multicast octets received with no error- 15 minute
Application
Valid for RPR Span
VCG ports
Valid for RPR Span
VCG ports
Valid for RPR Span
VCG ports
Valid for RPR Span
VCG ports
Valid for RPR Span
VCG ports
Number of Class B multicast frames received below CIR with no error- 15 minute
Number of Class B multicast octets received below CIR with no error- 15 minute
Valid for RPR Span
VCG ports
Valid for RPR Span
VCG ports
Number of Class B multicast frames received below EIR with no error- 15 minute
Number of Class B multicast octets received below EIR with no error- 15 minute
Valid for RPR Span
VCG ports
Valid for RPR Span
VCG ports
Number of Class C multicast frames received with no error- 15 minute
Number of Class C multicast octets received with no error- 15 minute
Valid for RPR Span
VCG ports
Valid for RPR Span
VCG ports
B - 1 2 1
SNMP Parameters and Traps
Table
: Performance Monitoring
dmxRprIntervalSpanOUC
AF dmxRprIntervalSpanOUC
AO dmxRprIntervalSpanOUC
BF dmxRprIntervalSpanOUC
BO dmxRprIntervalSpanOUC
BEF dmxRprIntervalSpanOUC
BEO dmxRprIntervalSpanOUC
CF dmxRprIntervalSpanOUC
CO
Object
dmxRprIntervalSpanOMC
AF dmxRprIntervalSpanOMC
AO
Description
Number of Class A unicast frames transmitted with no errors- 15 minute
Number of Class A unicast octets transmitted with no errors- 15 minute
Number of Class B unicast frames transmitted below
CIR with no errors- 15 minute
Number of Class B unicast octets transmitted below
CIR with no errors- 15 minute
Number of Class B unicast frames transmitted below
EIR with no errors- 15 minute
Number of Class B unicast octets transmitted below
EIR with no errors- 15 minute
Number of Class C unicast frames transmitted with no errors- 15 minute
Number of Class C unicast octets transmitted with no error- 15 minute
Number of Class A multicast frames transmitted with no error-
15 minute
Number of Class A multicast octets transmitted with no error- 15 minute
Application
Valid for RPR Span
VCG ports
Valid for RPR Span
VCG ports
Valid for RPR Span
VCG ports
Valid for RPR Span
VCG ports
Valid for RPR Span
VCG ports
Valid for RPR Span
VCG ports
Valid for RPR Span
VCG ports
Valid for RPR Span
VCG ports
Valid for RPR Span
VCG ports
Valid for RPR Span
VCG ports
B - 1 2 2
365-372-300
Issue 8.0 September 2006
SNMP Parameters and Traps
Table
: Performance Monitoring
Object
dmxRprIntervalSpanOMC
BF dmxRprIntervalSpanOMC
BO dmxRprIntervalSpanOMC
BEF dmxRprIntervalSpanOMC
BEO dmxRprIntervalSpanOMC
CF dmxRprIntervalSpanOMC
CO dmxRprIntervalDRATEF dmxRprIntervalDTAGF dmxRprIntervalDSPIF
Description
Number of Class B multicast frames transmitted below CIR with no error- 15 minute
Application
Valid for RPR Span
VCG ports
Number of Class B multicast octets transmitted below CIR with no error- 15 minute
Number of Class B multicast frames transmitted below EIR, no error- 15 minute
Valid for RPR Span
VCG ports
Valid for RPR Span
VCG ports
Number of Class B multicast octets transmitted below EIR with no error- 15 minute
Number of Class C multicast frames transmitted with no error-
15 minute
Valid for RPR Span
VCG ports
Valid for RPR Span
VCG ports
Number of Class C multicast octets transmitted with no error- 15 minute
Multicast and broadcast packets dropped due to exceeding port rate- 15 minute
Valid for RPR Span
VCG ports
Packets dropped due to
VLAN filtering- 15 minute
Packets dropped due to internal error (SPI4)- 15 minute
Bridge counters valid for LAN, RPR IF VCG
(not RPR Span VCG) port
Bridge counters valid for LAN, RPR IF VCG
(not RPR Span VCG) port
Bridge counters valid for LAN, RPR IF VCG
(not RPR Span VCG) port
365-372-300
Issue 8.0 September 2006
B - 1 2 3
SNMP Parameters and Traps
Table
: Performance Monitoring
dmxRprIntervalDNOTAG
F dmxRprIntervalIUCBRED
F
Object
dmxRprIntervalDSIZEF dmxRprIntervalDDMACF dmxRprIntervalDDMACO dmxRprIntervalDFCG dmxRprIntervalDFCY dmxRprIntervalIUCARED
F dmxRprIntervalIUCARED
O
Description
Packets dropped due to being greater then configured maximum frame size for port- 15 minute
Application
Bridge counters valid for LAN, RPR IF VCG
(not RPR Span VCG) port
Packets dropped due to no tag when required- 15 minute
Number of packets dropped due to MAC table destination address filtering- 15 minute
Number of octets dropped due to MAC table destination address filtering- 15 minute
Green packets dropped due to congestion- 15 minute
Yellow packets dropped due to congestion- 15 minute
Bridge counters valid for LAN, RPR IF VCG
(not RPR Span VCG) port
Bridge counters valid for LAN, RPR IF VCG
(not RPR Span VCG) port
Bridge counters valid for LAN, RPR IF VCG
(not RPR Span VCG) port
Bridge counters valid for LAN, RPR Span
VCG (not RPR IF
VCG) ports
Bridge counters valid for LAN, RPR Span
VCG (not RPR IF
VCG) ports
Number of Unicast packets assigned to Class A and given drop precedence of red- 15 minute
Number of Unicast octets assigned to Class A and given drop precedence of red- 15 minute
Number of Unicast packets assigned to Class B and given drop precedence of red- 15 minute
Metering counters valid for LAN ports only
Metering counters valid for LAN ports only
Metering counters valid for LAN ports only
B - 1 2 4
365-372-300
Issue 8.0 September 2006
SNMP Parameters and Traps
Table
365-372-300
Issue 8.0 September 2006
: Performance Monitoring
dmxRprIntervalIUCBRED
O dmxRprIntervalIUCCRED
F dmxRprIntervalIUCCRED
O dmxRprIntervalIMCBRED
F dmxRprIntervalIMCBRED
O dmxRprIntervalIMCCRED
F dmxRprIntervalIMCCRED
O
Object
dmxRprIntervalIMCARED
F dmxRprIntervalIMCARED
O dmxRprIntervalICTRF
Description
Number of Unicast octets assigned to Class B and given drop precedence of red- 15 minute
Application
Metering counters valid for LAN ports only
Number of Unicast packets assigned to Class C and given drop precedence of red- 15 minute
Number of Multicast octets assigned to Class C and given drop precedence of red- 15 minute
Metering counters valid for LAN ports only
Metering counters valid for LAN ports only
Number of Multicast packets assigned to Class A and given drop precedence of red- 15 minute
Number of Multicast octets assigned to Class A and given drop precedence of red- 15 minute
Metering counters valid for LAN ports only
Metering counters valid for LAN ports only
Number of Multicast packets assigned to Class B and given drop precedence of red- 15 minute
Number of Multicast octets assigned to Class B and given drop precedence of red- 15 minute
Metering counters valid for LAN ports only
Metering counters valid for LAN ports only
Number of Multicast packets assigned to Class C and given drop precedence of red- 15 minute
Number of Multicast octets assigned to Class C and given drop precedence of red- 15 minute
Number of control frames received- 15 minute
Metering counters valid for LAN ports only
Metering counters valid for LAN ports only
Span counters valid for
RPR Span VCG only
B - 1 2 5
SNMP Parameters and Traps
: Performance Monitoring
Table
dmxRprDayEntry
B - 1 2 6
Object
dmxRprIntervalIATDF dmxRprIntervalITPF dmxRprIntervalOCTRLF dmxRprIntervalOATDF dmxRprIntervalOTPF dmxRprIntervalITTLF dmxRprIntervalDLONG dmxRprIntervalDHEC dmxRprIntervalDSS dmxRprIntervalDSA dmxRprIntervalDPTY dmxRprIntervalDSCFF dmxRprDayIndex
Description
Number of ATD frames received- 15 minute
Number of TP frames received- 15 minute
Number of control frames transmitted- 15 minute
Number of ATD frames transmitted- 15 minute
Number of TP frames transmitted- 15 minute
Number of frames received with expired TTL values-
15 minute
Number of frames received with length exceeding the max allowed length- 15 minute
Number of frames received with HEC value not matching the expected HEC value- 15 minute
Number of frames received sourced by this station and then received by this station- 15 minute
Number of frames received with bad SA (Multicast or
Broadcast)- 15 minute
Number of frames received with Parity value not matching the expected
Parity value- 15 minute
Number of SCFF frames received with bad FCS or bad parity- 15 minute
Total 24 hour index
Application
Span counters valid for
RPR Span VCG only
Span counters valid for
RPR Span VCG only
Span counters valid for
RPR Span VCG only
Span counters valid for
RPR Span VCG only
Span counters valid for
RPR Span VCG only
Span counters valid for
RPR Span VCG only
Span counters valid for
RPR Span VCG only
Span counters valid for
RPR Span VCG only
Span counters valid for
RPR Span VCG only
Span counters valid for
RPR Span VCG only
Span counters valid for
RPR Span VCG only
Span counters valid for
RPR Span VCG only
365-372-300
Issue 8.0 September 2006
SNMP Parameters and Traps
Table
: Performance Monitoring
Object
dmxRprDaySpanIUCAF dmxRprDaySpanIUCAO dmxRprDaySpanIUCBF dmxRprDaySpanIUCBO dmxRprDaySpanIUCBEF dmxRprDaySpanIUCBEO dmxRprDaySpanIUCCF dmxRprDaySpanIUCCO dmxRprDaySpanIMCAF dmxRprDaySpanIMCAO dmxRprDaySpanIMCBF
Description
Number of Class A unicast frames received with no errors- 24 hour
Number of Class A unicast octets received with no errors- 24 hour
Number of Class B unicast frames received below CIR with no errors- 24 hour
Number of Class B unicast octets received below CIR with no errors- 24 hour
Number of Class B unicast frames received below EIR with no errors- 24 hour
Application
Valid for RPR Span
VCG ports
Valid for RPR Span
VCG ports
Valid for RPR Span
VCG ports
Valid for RPR Span
VCG ports
Valid for RPR Span
VCG ports
Number of Class B unicast octets received below EIR with no errors- 24 hour
Number of Class C unicast frames received with no errors- 24 hour
Number of Class C unicast octets received with no error- 24 hour
Number of Class A multicast frames received with no error- 24 hour
Valid for RPR Span
VCG ports
Valid for RPR Span
VCG ports
Valid for RPR Span
VCG ports
Valid for RPR Span
VCG ports
Number of Class A multicast octets received with no error- 24 hour
Number of Class B multicast frames received below CIR with no error- 24 hour
Valid for RPR Span
VCG ports
Valid for RPR Span
VCG ports
365-372-300
Issue 8.0 September 2006
B - 1 2 7
SNMP Parameters and Traps
Table
: Performance Monitoring
Object
dmxRprDaySpanIMCBO dmxRprDaySpanIMCBEF dmxRprDaySpanIMCBEO dmxRprDaySpanIMCCF dmxRprDaySpanIMCCO dmxRprDaySpanOUCAF dmxRprDaySpanOUCAO dmxRprDaySpanOUCBF dmxRprDaySpanOUCBO dmxRprDaySpanOUCBEF dmxRprDaySpanOUCBEO
Description
Number of Class B multicast octets received below CIR with no error- 24 hour
Application
Valid for RPR Span
VCG ports
Number of Class B multicast frames received below EIR with no error- 24 hour
Number of Class B multicast octets received below EIR with no error- 24 hour
Valid for RPR Span
VCG ports
Valid for RPR Span
VCG ports
Number of Class C multicast frames received with no error- 24 hour
Number of Class C multicast octets received with no error- 24 hour
Number of Class A unicast frames transmitted with no errors- 24 hour
Number of Class A unicast octets transmitted with no errors- 24 hour
Number of Class B unicast frames transmitted below
CIR with no errors- 24 hour
Number of Class B unicast octets transmitted below
CIR with no errors- 24 hour
Number of Class B unicast frames transmitted below
EIR with no errors- 24 hour
Number of Class B unicast octets transmitted below
EIR with no errors- 24 hour
Valid for RPR Span
VCG ports
Valid for RPR Span
VCG ports
Valid for RPR Span
VCG ports
Valid for RPR Span
VCG ports
Valid for RPR Span
VCG ports
Valid for RPR Span
VCG ports
Valid for RPR Span
VCG ports
Valid for RPR Span
VCG ports
B - 1 2 8
365-372-300
Issue 8.0 September 2006
SNMP Parameters and Traps
Table
: Performance Monitoring
dmxRprDaySpanOMCBE
O
Object
dmxRprDaySpanOUCCF dmxRprDaySpanOUCCO dmxRprDaySpanOMCAF dmxRprDaySpanOMCAO dmxRprDaySpanOMCBF dmxRprDaySpanOMCBO dmxRprDaySpanOMCBEF dmxRprDaySpanOMCCF dmxRprDaySpanOMCCO
Description
Number of Class C unicast frames transmitted with no errors- 24 hour
Application
Valid for RPR Span
VCG ports
Number of Class C unicast octets transmitted with no error- 24 hour
Number of Class A multicast frames transmitted with no error-
24 hour
Number of Class A multicast octets transmitted with no error- 24 hour
Number of Class B multicast frames transmitted below CIR with no error- 24 hour
Valid for RPR Span
VCG ports
Valid for RPR Span
VCG ports
Valid for RPR Span
VCG ports
Valid for RPR Span
VCG ports
Number of Class B multicast octets transmitted below CIR with no error- 24 hour
Number of Class B multicast frames transmitted below EIR, no error- 24 hour
Valid for RPR Span
VCG ports
Valid for RPR Span
VCG ports
Number of Class B multicast octets transmitted below EIR with no error- 24 hour
Number of Class C multicast frames transmitted with no error-
24 hour
Number of Class C multicast octets transmitted with no error- 24 hour
Valid for RPR Span
VCG ports
Valid for RPR Span
VCG ports
Valid for RPR Span
VCG ports
365-372-300
Issue 8.0 September 2006
B - 1 2 9
SNMP Parameters and Traps
Table
: Performance Monitoring
Object
dmxRprDayDRATEF dmxRprDayDTAGF dmxRprDayDSPIF dmxRprDayDSIZEF dmxRprDayDNOTAGF dmxRprDayDSMACF dmxRprDayDSMACO dmxRprDayDFCG dmxRprDayDFCY
Description
Multicast and broadcast packets dropped due to exceeding port rate- 24 hour
Application
Bridge counters valid for LAN, RPR IF VCG
(not RPR Span VCG) port
Packets dropped due to
VLAN filtering- 24 hour
Packets dropped due to internal error (SPI4)- 24 hour
Packets dropped due to being greater then configured maximum frame size for port- 24 hour
Packets dropped due to no tag when required- 24 hour
Bridge counters valid for LAN, RPR IF VCG
(not RPR Span VCG) port
Bridge counters valid for LAN, RPR IF VCG
(not RPR Span VCG) port
Bridge counters valid for LAN, RPR IF VCG
(not RPR Span VCG) port
Bridge counters valid for LAN, RPR IF VCG
(not RPR Span VCG) port
Number of packets dropped due to MAC table source address filtering- 24 hour
Number of octets dropped due to MAC table source address filtering- 24 hour
Bridge counters valid for LAN, RPR IF VCG
(not RPR Span VCG) port
Bridge counters valid for LAN, RPR IF VCG
(not RPR Span VCG) port
Green packets dropped due to congestion- 24 hour
Yellow packets dropped due to congestion- 24 hour
Bridge counters valid for LAN, RPR Span
VCG (not RPR IF
VCG) ports
Bridge counters valid for LAN, RPR Span
VCG (not RPR IF
VCG) ports
B - 1 3 0
365-372-300
Issue 8.0 September 2006
SNMP Parameters and Traps
Table
: Performance Monitoring
Object
dmxRprDayIUCAREDF dmxRprDayIUCAREDO dmxRprDayIUCBREDF dmxRprDayIUCBREDO dmxRprDayIUCCREDF dmxRprDayIUCCREDO dmxRprDayIMCAREDF dmxRprDayIMCAREDO dmxRprDayIMCBREDF
Description
Number of Unicast packets assigned to Class A and given drop precedence of red- 24 hour
Number of Unicast octets assigned to Class A and given drop precedence of red- 24 hour
Number of Unicast packets assigned to Class B and given drop precedence of red- 24 hour
Number of Unicast octets assigned to Class B and given drop precedence of red- 24 hour
Number of Unicast packets assigned to Class C and given drop precedence of red- 24 hour
Application
Metering counters valid for LAN ports only
Metering counters valid for LAN ports only
Metering counters valid for LAN ports only
Metering counters valid for LAN ports only
Metering counters valid for LAN ports only
Number of Multicast octets assigned to Class C and given drop precedence of red- 24 hour
Number of Multicast packets assigned to Class A and given drop precedence of red- 24 hour
Metering counters valid for LAN ports only
Metering counters valid for LAN ports only
Number of Multicast octets assigned to Class A and given drop precedence of red- 24 hour
Number of Multicast packets assigned to Class B and given drop precedence of red- 24 hour
Metering counters valid for LAN ports only
Metering counters valid for LAN ports only
365-372-300
Issue 8.0 September 2006
B - 1 3 1
SNMP Parameters and Traps
Table
: Performance Monitoring
Object
dmxRprDayIMCBREDO dmxRprDayIMCCREDF dmxRprDayIMCCREDO dmxRprDayICTRF dmxRprDayIATDF dmxRprDayITPF dmxRprDayOCTRLF dmxRprDayOATDF dmxRprDayOTPF dmxRprDayITTLF dmxRprDayDLONG dmxRprDayDHEC
Description
Number of Multicast octets assigned to Class B and given drop precedence of red- 24 hour
Application
Metering counters valid for LAN ports only
Number of Multicast packets assigned to Class C and given drop precedence of red- 24 hour
Number of Multicast octets assigned to Class C and given drop precedence of red- 24 hour
Metering counters valid for LAN ports only
Metering counters valid for LAN ports only
Number of control frames received- 24 hour
Number of ATD frames received- 24 hour
Number of TP frames received- 24 hour
Number of control frames transmitted- 24 hour
Span counters valid for
RPR Span VCG only
Span counters valid for
RPR Span VCG only
Span counters valid for
RPR Span VCG only
Span counters valid for
RPR Span VCG only
Span counters valid for
RPR Span VCG only
Span counters valid for
RPR Span VCG only
Number of ATD frames transmitted- 24 hour
Number of TP frames transmitted- 24 hour
Number of frames received with expired TTL values-
24 hour
Number of frames received with length exceeding the max allowed length- 24 hour
Number of frames received with HEC value not matching the expected HEC value- 24 hour
Span counters valid for
RPR Span VCG only
Span counters valid for
RPR Span VCG only
Span counters valid for
RPR Span VCG only
B - 1 3 2
365-372-300
Issue 8.0 September 2006
SNMP Parameters and Traps
Table Object
dmxRprDayDSS dmxRprDayDSA dmxRprDayDPTY dmxRprDayDSCFF
: Performance Monitoring
Description
Number of frames received sourced by this station and then received by this station- 24 hour
Number of frames received with bad SA (Multicast or
Broadcast)- 24 hour
Number of frames received with Parity value not matching the expected
Parity value- 24 hour
Number of SCFF frames received with bad FCS or bad parity- 24 hour
Application
Span counters valid for
RPR Span VCG only
Span counters valid for
RPR Span VCG only
Span counters valid for
RPR Span VCG only
Span counters valid for
RPR Span VCG only
365-372-300
Issue 8.0 September 2006
B - 1 3 3
SNMP Parameters and Traps
: Performance Monitoring
RPR Private Alarms
Starting in Release 6.0/4.0, DMX/DMXtend supports RPR alarms for the generation of private alarm traps as specified in the table below
(there are no traps specified in the RPR IEEE P802.17/D3.3 MIB). The specific type of alarm trap object to be issued depends on whether the alarm, when it occurs is an alarm, alarm cleared, standing condition, standing condition cleared or transient condition.
RPR Private Trap MIB Module dmxAlarmId
dmxEXSRSV dmxEXSRSVClr dmxTOPOUNST dmxTOPOUNSTClr dmxTOPOINCS dmxTOPOINCSClr dmxTOPOINV dmxTOPOINVClr dmxTOPOMAX dmxTOPOMAXClr dmxMISCBL dmxMISCBLClr dmxKALVTO dmxTOPOINCS dmxTOPOINCSClr
Description
RPR SPAN VCG - Excessive Reserved Rate on RPR
RPR SPAN VCG - Excessive Reserved Rate on RPR clear
RPR IF - RPR Topology Unstable
RPR IF - RPR Topology Unstable clear
RPR IF - RPR Topology Inconsistency
RPR IF - RPR Topology Inconsistency clear
RPR IF - RPR Topology Map Entry Invalid
RPR IF - RPR Topology Map Entry Invalid clear
RPR IF - RPR Topology Exceeded Max Stations
RPR IF - RPR Topology Exceeded Max Stations clear
RPR SPAN VCG - RPR Miscabling
RPR SPAN VCG - RPR Miscabling clear
RPR IF - RPR Keep-Alive Timeout
RPR IF - RPR Topology Inconsistency
RPR IF - RPR Topology Inconsistency clear
B - 1 3 4
365-372-300
Issue 8.0 September 2006
C: IS-IS Level 2 Routing Guidelines
Overview
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Purpose
This appendix details the guidelines for IS-IS Level 2 Routing in networks larger than 250 OSI nodes.
Contents
The following topics are included in this appendix:
IS-IS Level 2 Routing Remote Provisioning Sequence
IS-IS Level 2 Routing Provisioning Confirmation
Engineering Rules and Guidelines
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
C - 1
: IS-IS Level 2 Routing Guidelines
Introduction
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Overview
If network sizes of more than 250 OSI nodes are required, hierarchical routing makes it possible to increase the number of nodes in an OSI management domain, (for example, NEs with OSI LAN and/or DCC connectivity for operations communications among the NEs).
Increasing the number OS nodes is achieved through the use of IS-IS
Level 2 Routing.
IS-IS Level 2 Routing involves assigning NEs to multiple areas of 250 nodes or less. Level 2 routers support OSI communications between the
NEs in different areas. Both the assignment of NEs to areas and the enabling of NEs as Level 2 routers is accomplished by provisioning
(refer to
“Area Address Assignment” (C-4)
and
Assignment” (C-6) , respectively).
OSI Node vs. NE terminology
Each DMX is an OSI node, but some other NEs support multiple OSI nodes within a single NE, so the term “OSI node”, or simply “node”, is generally used in this context instead of “NE”.
Advantages
The primary advantage of IS-IS Level 2 Routing is to limit the OSI routing information that needs to be maintained by each node. Each node within an area maintains routing tables to route OSI LAN and
DCC messages to the other nodes in the same area. If a node needs to route a message to a node in a different area, the node relies on a
Level 2 router in its own area to route the message to a Level 2 router in the target area and from that Level 2 router to the target node within that area.
The Level 2 routers route messages between nodes in different areas.
These messages include all of the NE-NE (and OS-NE) OSI communications required for the supported OI applications, (for example, TL1 login messages from TL1-GNEs to TL1-RNEs.)
In addition to maintaining a routing table to route messages to other nodes in the same area, Level 2 routers need to maintain routing information for the Level 2 routers in all other areas (but not for all nodes within each of those other areas).
...........................................................................................................................................................................................................................................................
C - 2
365-372-300
Issue 8.0 September 2006
Introduction
: IS-IS Level 2 Routing Guidelines
Symbols
The graphical examples is this appendix use the symbols that are defined in the following figure.
Figure C-1 illustrates an example
network with nodes assigned to four different areas connected by Level
2 routers.
Figure C-1 Network with Level 2 Routers
Area 1
Level 2 Subdomain
Area 2
Area 4
Area 3
= NE Level 1 Router
= NE Level 2 Router
= Generic Level 2 Router
= SNMS
= OSI LAN
= DCC
= Area
= Level 2 Subdomain
NC-DMX-042
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
C - 3
: IS-IS Level 2 Routing Guidelines
Area Address Assignment
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Area address
The area address is the first 26 characters of each DMX Network
Services Access Point (NSAP). [DMX supports a fixed-length 40character (20-byte) NSAP only.] The first eight characters of the
NSAPs are always the same and cannot be changed. The remaining
18 characters of the NSAP area address are provisionable but only the
Area field should be changed to assign a node to a different area. The remainder of the NSAP includes the System Identifier field, which is unique to each node, and the Selector (SEL) field.
The following table provides a break-down of an NSAP.
Table C-1 Area Addresses
NSAP Field: AFI IDI
1 2
IDI
PAD
DFI
1 Bytes:
Default Value:
(hex)
39 840 F 80 not provisionable
Organization
ID
RES RD Area
System
Identifier
SEL
3 2 2 2 6 1
000000 0000 0000 0000 user provisionable none not
00 provisionable
A group of nodes are assigned to an area by changing each node’s
NSAP Area field to the same value. The entire NSAP area address must be identical for all nodes in an area and different from the NSAP area addresses for all other areas.
If more than one separate area with the same area address exists, routing to these areas from other areas would not be predictable and couldn’t be expected to function properly.
...........................................................................................................................................................................................................................................................
C - 4
365-372-300
Issue 8.0 September 2006
Area Address Assignment
: IS-IS Level 2 Routing Guidelines
Area field
The Area field consists of four hexadecimal characters, with a default value of 0000 (hex). TL1 command
ENT-ULSDCC-L3
can be used to change the Area field.
Area Terminology
Despite the technical differences between the area address and the Area field described previously, the term area address is commonly used to refer to the Area field value. Thus, for convenience, the term area address is used throughout this document.
Multiple area addresses
Multiple area addressing is the capability for a node to be assigned more than one area address. The provisioning of multiple area addresses is not supported on DMX, directly. However, if multiple area addresses are provisioned in another node, DMX would recognize its own primary area address plus up to two other area addresses. The use of multiple area addresses is not recommended.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
C - 5
: IS-IS Level 2 Routing Guidelines
Level 2 Router Assignment
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Overview
OSI communications is supported within a network which may consist of a single area or multiple areas. Level 1 routers provide interconnectivity between nodes in an area (all DMXs are Level 1 routers). Level 2 routers provide connectivity between areas.
Guidelines and default
In a network with multiple areas, each area must contain at least one
Level 2 router. An area without a Level 2 router would be isolated from the rest of the network. The adjacent set of Level 2 routers form the
Level 2 subdomain. For proper OSI routing, every Level 2 router should have at least one neighbor (via OSI LAN or DCC) that is also a
Level 2 router. At least one of the Level 2 routers in an area must be adjacent to a Level 2 router in another area, otherwise, the former area would be isolated from the rest of the network.
Each DMX is not a Level 2 router by default. TL1 command
ENT-ULSDCC-L3
can be used to enable any DMX as a Level 2 router.
...........................................................................................................................................................................................................................................................
C - 6
365-372-300
Issue 8.0 September 2006
: IS-IS Level 2 Routing Guidelines
IS-IS Level 2 Routing Remote Provisioning Sequence
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Avoid isolating nodes
An important goal is to avoid isolating any nodes when provisioning area addresses and Level 2 routers remotely. Isolating a node may require craft dispatch to the isolated node to recover. To avoid isolating nodes, the sequence for remote provisioning is established with respect to the local node to which the WaveStar
®
CIT is connected or the
TL1-GNE through which Navis™ Optical Element Management
System (Navis™ Optical EMS) is connected. Typically, the local node or TL1-GNE is provisioned to be a Level 2 router first, but its area address is not changed initially. This general sequence can be modified in networks with redundant OSI LAN or DCC connectivity between and within areas.
1.
The nodes and sub-tending rings that are furthest away from this local node or TL1-GNE are provisioned first.
2.
Work back toward the local node or TL1-GNE’s sub-tending ring.
3.
Provision the local node or TL1-GNE’s sub-tending ring.
4.
Provision the local node or TL1-GNE last.
If Navis™ Optical EMS is part of the network via an OSI LAN or
WAN interface, provision the area address for the Navis™ Optical
EMS.
Important!
Before assigning area addresses and Level 2 routers in a network, be sure no alarms (especially
DCC failure
alarms) exist; otherwise, even the recommended remote provisioning sequence might result in isolated nodes. To confirm the network alarm status, it is recommended that a centralized maintenance center with TL1 OS support be consulted.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
C - 7
IS-IS Level 2 Routing Remote Provisioning Sequence
: IS-IS Level 2 Routing Guidelines
Provisioning sub-tending rings
Always provision new area addresses for a sub-tending ring by starting with a node that is adjacent to the node that connects this sub-tending ring to the rest of the network, and then provision the area address for each sequential adjacent node going around the sub-tending ring.
Provision the area address of the connecting node last, especially if the connecting node supports multiple sub-tending rings.
For single-homed sub-tending rings, provision the node that will be the
Level 2 router node last; otherwise, nodes in its area could be isolated.
For dual-homed rings, provision one of the nodes that will be Level 2 router first, so that OSI connectivity is established with provisioned nodes as soon as they complete their controller resets.
Minimizing OSI communications disruption
Another important goal is to provision the network in such a way that
OSI communications disruption is minimized. Changing a node’s area address and/or enabling a node as a Level 2 router causes the node to reset its controller. The reset is immediate and is part of the completion of the command. In addition to temporarily disrupting OSI communications, controller resets temporarily disable automatic transmission protection switching.
As one node is undergoing a controller reset in an area, the next adjacent node should be provisioned to minimize the overall time required to provision the nodes in an area and minimize the time that
OSI communications with the nodes in the area are lost.
Changing a node’s area address and enabling a node as a Level 2 router, if appropriate, should usually both be done with a single command per node.
...........................................................................................................................................................................................................................................................
C - 8
365-372-300
Issue 8.0 September 2006
: IS-IS Level 2 Routing Guidelines
IS-IS Level 2 Routing Provisioning Confirmation
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Overview
TL1
RTRV-MAP-NETWORK
commands can be used to confirm the area address and Level 2 router assignments of all nodes with OS LAN or
DCC connectivity in a network.
Small networks
In a small network without IS-IS Level 2 Routing, the
RTRV-MAP-
NETWORK
response includes the NSAPs (including the embedded area address field) of the local node and all remote nodes. This command may also be useful to confirm the uniqueness of the area addresses before combining two existing networks into one large network requiring IS-IS Level 2 Routing.
Large networks
In large networks with IS-IS Level 2 Routing, the
RTRV-MAP-
NETWORK
response can vary based on whether or not the local node is a Level 2 router itself.
1.
If the local node is not a Level 2 router, the response includes only remote nodes in the same OSI area as the local node and indicates which remote node is the default Level 2 router for the local node.
The default Level 2 router is the node that the local node would rely on to route an OSI message outside the local NE’s own area.
When there are multiple Level 2 routers in the same area, not all nodes in the area would identify the same default Level 2 router typically.
2.
If the local node is a Level 2 router, user input dictates whether the response includes: a.
only remote nodes in the same OSI area as the local node (as in #1 above) but indicating which of those remote nodes are
Level 2 routers b.
all remote nodes that are Level 2 routers across all OSI areas.
Thus, with a
RTRV-MAP-NETWORK
command to one Level 2 router in each area, all nodes in a large network with IS-IS Level 2 Routing can be identified. One
RTRV-MAP-NETWORK
command at at time per area should suffice and is recommended to avoid unnecessarily burdening the network with many simultaneous or redundant TARP queries.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
C - 9
IS-IS Level 2 Routing Provisioning Confirmation
: IS-IS Level 2 Routing Guidelines
Problem isolation
TL1 command
RTRV-MAP-NEIGHBOR
may indicate and help resolve
IS-IS Level 2 Routing provisioning mistakes. This command highlights any neighbors with which DCC is enabled but OSI communications is not fully functional. When addressed to a reachable node with an unreachable neighbor, this command identifies the NSAP area address and the Level 2 router status, if known, of the unreachable neighbor.
The unreachable neighbor may simply have the wrong area address or both nodes may need to be enabled as Level 2 routers.
There is no standing alarm or status condition at a node with Level 2 router functionality enabled or disabled. There is no automatic means of determining whether the area address is consistent with the rest of the network. The user must confirm that all IS-IS Level 2 Routing rules have been followed to ensure successful OSI communications among the nodes in a network.
...........................................................................................................................................................................................................................................................
C - 1 0
365-372-300
Issue 8.0 September 2006
: IS-IS Level 2 Routing Guidelines
Maximum Number of OSI Nodes
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Maximum number of nodes per area and OSI domain
The total number of nodes per OSI area cannot exceed 250. The total number of nodes in the OSI domain cannot exceed 1000.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
C - 1 1
: IS-IS Level 2 Routing Guidelines
Engineering Rules and Guidelines
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Overview
To use IS-IS Level 2 Routing, the user must plan and engineer the provisioning of Level 2 routers and area addresses in the network.
The goal is to create a network with all nodes having OSI LAN or DCC connectivity with each other so that access to all the nodes can be gained from any node in the network.
Rules must be followed to assure OSI LAN and DCC message routing.
Guidelines are recommendations that add survivability in the event of a node, OSI LAN or DCC failure. Rules must be followed. Guidelines
should be followed. There may be customer applications that cannot adhere to some or all of the guidelines. In most cases, the potential consequence is that a single failure would at least partially disrupt operations communications.
...........................................................................................................................................................................................................................................................
C - 1 2
365-372-300
Issue 8.0 September 2006
Engineering Rules and Guidelines
: IS-IS Level 2 Routing Guidelines
Rule: OSI LAN or DCC connectivity within an area
All nodes in an area must have OSI LAN or DCC connectivity within the area to all other nodes in the same area. Otherwise, the area would be segmented and message routing could not be expected to function properly.
Figure C-2 illustrates a correct and an incorrect example of
assigning nodes to areas.
Figure C-2 Assigning Areas
CORRECT
INCORRECT Both A and B are isolated
= NE Level 1 Router
= NE Level 2 Router
= DCC
= Area
A
B
nc-dmx-043
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
C - 1 3
Engineering Rules and Guidelines
: IS-IS Level 2 Routing Guidelines
Rule: single Level 2 router subdomain
All Level 2 routers must have OSI LAN or DCC connectivity, either directly or indirectly via other Level 2 routers, to all other Level 2 routers in the network to form a single Level 2 router subdomain that provides connectivity to all areas. If more than one Level 2 router subdomain exists, the network becomes segmented and routing will not function properly.
Figure C-3 illustrates a correct and two incorrect examples of assigning
a Level 2 router subdomains.
Figure C-3 Assigning Subdomains
CORRECT
INCORRECT
This Level 2 router subdomain and area are isolated
INCORRECT
This area is isolated
= NE Level 1 Router
= NE Level 2 Router
= DCC
= Area
= Level 2 Subdomain nc-dmx-044
...........................................................................................................................................................................................................................................................
C - 1 4
365-372-300
Issue 8.0 September 2006
Engineering Rules and Guidelines
: IS-IS Level 2 Routing Guidelines
Guideline: redundant routes within the Level 2 subdomain
When practical, redundant routes in the Level 2 subdomain should be available between all Level 2 routers to ensure that proper routing will occur in the event of a single failure. To satisfy this guideline, every
Level 2 router has at least two other Level 2 routers as direct neighbors.
Figure C-4 illustrates a recommended example and an example that is
not recommended for redundant routes within the Level 2 subdomain:
Figure C-4 Redundant Routes with the Level 2 Subdomain
RECOMMENDED
This Level 2 IS has only one neighboring
Level 2 IS
NOT RECOMMENDED
= NE Level 1 Router
= NE Level 2 Router
= Generic Level 2 Router
= SNMS
= OSI LAN/WAN
= DCC
= Area
= Level 2 Subdomain nc-dmx-045
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
C - 1 5
Engineering Rules and Guidelines
: IS-IS Level 2 Routing Guidelines
Guideline: Level 2 router assignment in a ring
The recommended number of Level 2 routers in a ring may be one of the following:
• None
• One
• All nodes in the ring
• Two; for example, when dual-homing or dual ring interworking
(DRI) is used.
Figure C-5 illustrates examples of recommended Level 2 router
assignments in various ring configurations.
Figure C-5 Recommended Level 2 Router Assignments
All Level 2 routers
No Level 2 routers
One Level 2 router
Two adjacent
Level 2 routers (DRI)
= NE Level 1 Router
= NE Level 2 Router
= Generic Level 2 Router
= SNMS
= OSI LAN/WAN
= DCC
Two adjacent
Level 2 routers nc-dmx-046
...........................................................................................................................................................................................................................................................
C - 1 6
365-372-300
Issue 8.0 September 2006
Engineering Rules and Guidelines
: IS-IS Level 2 Routing Guidelines
Guideline: Level 2 router area assignments in a ring
For a ring of Level 2 routers, the recommended area assignments may be one of the following:
• All Level 2 routers are part of the same area.
• Each Level 2 router is part of a different area.
• A pair of adjacent Level 2 routers are in the same area (for example, with dual-homing or DRI), with either the other Level 2 routers similarly paired off or individually in different areas.
Figure C-6 illustrates examples of recommended Level 2 router area
assignments in a ring.
Figure C-6 Recommended Area Assignments same area different areas
= NE Level 1 Router
= NE Level 2 Router
= DCC
= Area
dual homing different areas
NC-DMX-047
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
C - 1 7
Engineering Rules and Guidelines
: IS-IS Level 2 Routing Guidelines
Guideline: adjacent Level 2 routers within an area
It is recommended that dual Level 2 routers in an area be adjacent to each other and have a redundant route within the area. Failure to meet this guideline would result in some messages not being routed properly in the event of a single failure that divides an area into two separate islands.
Figure C-7 illustrates a recommended example and two examples that
are not recommended of dual Level 2 routers in an area:
Figure C-7 Recommended Placement of Level 2 Routers
Failure
A
B
Z
RECOMMENDED
If A or B sends a message to Z and there is a DCC failure between A and Z, routing will survive the failure.
A
B
Failure
Z
NOT RECOMMENDED
If A or B sends a message to Z and there is a DCC failure between A and Z, routing will not be successful.
Failure
B
A
Z
NOT RECOMMENDED
If A or B sends a message to Z and there is a DCC failure between A and Z, routing will not be successful.
= NE Level 1 Router
= NE Level 2 Router
= DCC
= Area nc-dmx-048
...........................................................................................................................................................................................................................................................
C - 1 8
365-372-300
Issue 8.0 September 2006
Engineering Rules and Guidelines
: IS-IS Level 2 Routing Guidelines
Guideline: Navis™ Optical
EMS own area address and
Level 2 router
If Navis™ Optical EMS (or any other OS) access is via OSI LAN (or
WAN), Navis™ Optical EMS should be assigned to a different area and rely on a generic Level 2 router to communicate with a large network. (Navis™ Optical EMS is not expected to be a Level 2 router itself.) This is recommended to avoid routing all messages to/from
Navis™ Optical EMS through a single NE serving as a Level 2 router.
Although not shown in the examples below, Navis™ Optical EMS can support a second, redundant OSI LAN port. Each Navis™ Optical
EMS OSI LAN port has its own unique NSAP but both must be assigned the same area address.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
C - 1 9
Engineering Rules and Guidelines
: IS-IS Level 2 Routing Guidelines
Figure C-8 illustrates a recommended example, an example that is not
recommended, and an incorrect example of Navis™ Optical EMS access via OSI LAN/WAN.
Figure C-8 Recommended Navis™ Optical EMS Access via OSI
LAN/WAN
Generic Level 2
Router for Navis
TM
Optical EMS instead of an NE
RECOMMENDED
All Navis
TM
Optical EMS messages through this one node
NOT RECOMMENDED
Navis
TM
Optical
EMS has a unique area address but no
Level 2 router
INCORRECT
= NE Level 1 Router
= NE Level 2 Router
= Generic Level 2 Router
TM
= Navis Optical EMS
= OSI LAN/WAN
= DCC
= Area nc-dmx-049
...........................................................................................................................................................................................................................................................
C - 2 0
365-372-300
Issue 8.0 September 2006
Engineering Rules and Guidelines
: IS-IS Level 2 Routing Guidelines
Rule: Level 2 routers on an
OSI LAN
If an OSI LAN (or WAN) is used to connect between areas, then at least one node in each area on the OSI LAN must be provisioned to be a Level 2 router. Otherwise, the areas won’t route to each other via the
OSI LAN.
Figure C-9 illustrates a correct and an incorrect example of Level 2
router assignments on an OSI LAN:
Figure C-9 Level 2 Router Assignments on an OSI LAN
CORRECT
INCORRECT
This area is isolated
= NE Level 1 Router
= NE Level 2 Router
= Generic Level 2 Router
= Navis
TM
Optical EMS
= OSI LAN/WAN
= DCC
= Area nc-dmx-050
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
C - 2 1
Engineering Rules and Guidelines
: IS-IS Level 2 Routing Guidelines
Guideline: OSI LAN redundancy
If an OSI LAN (or WAN) is the only method of connecting between areas, then at least two Level 2 routers directly connected to the
OSI LAN for each area are recommended for redundancy purposes. A second, separate OSI LAN hub would provide additional redundancy.
Figure C-10 illustrates a recommended example for providing
redundancy between areas connected solely by OSI LANs:
Figure C-10 OSI LAN Redundancy
RECOMMENDED
= NE Level 1 Router
= NE Level 2 Router
= Generic Level 2 Router
TM
= Navis Optical EMS
= OSI LAN/WAN
= DCC
= Area nc-dmx-051
...........................................................................................................................................................................................................................................................
C - 2 2
365-372-300
Issue 8.0 September 2006
D Physical, Electrical, and
Thermal Compatibility
Requirements for OSP
Applications
Overview
............................................................................................................................................................................................................................................................
Purpose
This document details the specific requirements and standards that must be adhered to when installing the DMX, DMXtend, and
DMXplore in Outside Plant (OSP) cabinets. It describes the physical, electrical, and thermal requirements necessary to ensure Metropolis
®
DMXtend Access Multiplexer equipment operates reliably in OSP applications.
A cabinet that does not meet the requirements of this document will negatively affect the performance, reduce service life, and threaten service continuity of the Metropolis
®
DMXtend Access Multiplexer products described herein.
This document should be used by equipment suppliers, service providers and equipment system integrators of network access equipment.
Important!
This document is not intended to be used as a cabinet-level end-product requirements document. Cabinet level, end-product requirements (e.g., cabinet level electrical emissions, needed battery backup, etc) must be agreed to by the system supplier and customer.
............................................................................................................................................................................................................................................................
365-372-324
Issue 4.2, April 2006
D - 1
Overview
Appendix D
Definitions Requirement
Feature or function that is necessary to satisfy the needs of an end user.
A requirement contains the words shall or must.
Objective
Feature or function that is desirable and may be required by an end user. An objective contains the words should or may.
Metropolis
®
DMX/DMXtend
Whenever “Metropolis
®
DMX products/services” is used in this section, it refers to the DMX, DMXtend, and DMXplore products only.
Contents
The following hardware is described in this chapter:
Electrical Requirements and Objectives
Environmental Requirements and Objectives
Test Verification and Qualification
...........................................................................................................................................................................................................................................................
D - 2
365-372-324
Issue 4.2, April 2006
Appendix D
Shelf Description
............................................................................................................................................................................................................................................................
Overview
The figures below illustrate typical shelf configuration for the four
Metropolis
®
DMX Access Multiplexer products. Meeting the requirements in this document for the Metropolis
®
DMXtend Access
Multiplexer shelves will ensure proper operation of all cabinet applications.
DMX Side/Front View Figure D-1 DMX Shelf Side/Front View with Mounting Bracket
19”
LNW6
Sx:x
28DS1
LUCENT
LNW6
Sx:x
28DS1
LUCENT
LNW16
Sx:x
12DS3/EC1
LUCENT
LNW16
Sx:x
12DS3/EC1
LUCENT
LNW67
Sx:x
1G SX
LUCENT
OC-48
1310 LR
LUCENT
LNW1
Sx:x
SYSCTL
LUCENT
177D
Sx:x
BLANK
LUCENT
OC-48
1310 LR
LUCENT
LNW36
Sx:x
OC-3
LUCENT
LNW36
Sx:x
OC-3
LUCENT
OC-12
1310LR
LUCENT
OC-12
1310LR
LUCENT
FAULT
ACTIVE
28DS1
FAULT
ACTIVE
FAULT
ACTIVE
FAULT
ACTIVE
28DS1 12DS3/
EC1
12DS3/
EC1
FAULT
ACTIVE
1G SX
OUT
1
2
IN
FAULT
ACTIVE
OC-48
OLIU
OUT IN
FAULT
CR
MJ
MN
ABN
FE
NE
ACO
ACO
TEST
IND
SEL
UPD/
INT
LAN
CIT
RS
232
177D
BLANK
FAULT
ACTIVE
OC-48
OLIU
FAULT
ACTIVE
OC-3
OLIU
OC-3
OLIU
OUT IN OUT IN
FAULT
ACTIVE
FAULT
ACTIVE
OC-12
OLIU
FAULT
ACTIVE
OC-12
OLIU
OUT IN 1 1
OUT IN OUT IN
1 1 2
3
2
3
2 2
4 4
Heat Baffle
A1 A2 B1 B2
Metropolis
®
DMX
G1 M1 CTL G2 M2 C1 C2 D1
OFF
ON
D2
13.75"
17.6”
MA DMX 410
DMXtend Side/Front View Figure D-2 DMXtend Shelf Side/Front View with Mounting
Bracket
Fan Filter
BRK A 10A
ON
BRK B 10A
ON
8.75”
Fiber
Tray
Metropolis
®
DMXtend
CTL
G2
G1
LNW39
DS1/DS3/16/31
Lucent
LNW39
DS1/DS3/16/31
Lucent
A2/B2
A1/B1
D2
12DS3/EC1
12DS3/EC1
M2
OUT IN
M1
OUT
IN
28DS1
LNW40
Sx:x
OC3/1.3IR1
Lucent
LNW40
Sx:x
OC3/1.3IR1
Lucent
Lucent
Fan Unit
POWER
FAULT
13.75”
17.5”
MA-DMXtend-096
............................................................................................................................................................................................................................................................
365-372-324
Issue 4.2, April 2006
D - 3
Shelf Description
Appendix D
DMXplore Wall-mount Side/
Front View
Figure D-3 DMXplore Wall-mount Shelf Side/Front View with
Mounting Bracket
10.5”
FAULT
CR/MJ
MN/ABN
ACO
LAN
CIT
RS-232
IN
OUT
VLNC6
S1:1
XX:x
Lucent
FAULT
ACTIVE
IN
OUT
FAULT
ACTIVE
XX:x
Lucent
PWR-A
ON
PWR-B
ON
-48V-A
RTN-A
RTN COM
GRD
RTN-B
-48V-B
1 2 3 4
C GROUP
OUT
1 2 3
1
B GROUP
2 3 4
IN
5
9
6 7
A/D GROUP
10 11
8
12
13 14 15 16
MDI MDO ALARM
VLNC1
S1:1
SYSCTL
Lucent
CTL
12”
7.5”
DMXplore Rack-mount
Shelf Side/Front View
Figure D-4 DMXplore Rack-mount Side/Front View with
Mounting Bracket
MA-DMXplore-042
FAN
FAULT
A
PWR ON
PWR ON
B
Lucent
3.5
17.3”
MA-DMXplore-043
13.5”
...........................................................................................................................................................................................................................................................
D - 4
365-372-324
Issue 4.2, April 2006
Shelf Description
Appendix D
Metropolis
®
DMXtend
Access Multiplexer Product
Conformance
Metropolis
®
DMXtend Access Multiplexer equipment has been designed and tested to meet industry requirements for physical, electrical, thermal and product safety characteristics.
Principal requirements for Metropolis
®
DMX equipment are as follows:
• GR-63, covering physical requirements (earthquake resistance, thermal shock, fire, etc.)
1
• GR-1089 covering electrical requirements (electromagnetic interference, electrostatic discharge, grounding, etc.)
2
• CSA-C22.2, No. 60950-00, UL60950
3
Safety of information technology equipment.
............................................................................................................................................................................................................................................................
365-372-324
Issue 4.2, April 2006
D - 5
Appendix D
Physical Requirements
............................................................................................................................................................................................................................................................
Cabinet Design and
Equipment Reliability
Outside plant cabinets for use with Metropolis
®
DMX equipment in
NAR applications shall have demonstrated compliance in accordance with GR-487
4
. GR-487 describes cabinet level requirements to ensure a suitable environment for telecommunications equipment. Typical requirements covered in this specification include Water and Dust
Intrusion, Wind-Driven Rain, Thermal Shock, Impact Resistance and
Shock and Vibration.
The table below shows the dimensions of the Metropolis
®
DMX equipment.
Table D-1 Metropolis
®
Dimensions and Weight
Dimensions
1
DMX
Width
Height
Depth
17.6
19
13.75
2
Center-to-Center Mounting Hole Width 22.31
Metropolis
®
Products
DMXtend DMXplore
Wall Mount Rack Mount
7.5
17.5
8.75
15
22.31
10.5
12.0
NA
3
17.3
3.5
13.5
22.31
Vertical Hole Spacing
Mounting Screw Size
(thread forming screw)
A pattern of 0.5 inch spacing.
No. 12x24
Shelf Weight lbs 38 Empty
57 Full
15 Empty
30 Full
7 Empty
10 Full
1) All dimensions are provided in inches unless otherwise specified
2) 15 inches with interface connectors. 16 inches with connectors and cover.
3) Not applicable for a wall-mounted DMXplore. For a Rack-mount or rack-mounted Wall-mount version of the
DMXplore the center-to-center mounting hole width is 22.31”.
...........................................................................................................................................................................................................................................................
D - 6
365-372-324
Issue 4.2, April 2006
Physical Requirements
Appendix D
Mounting Bracket
Positions
The figure below illustrates typical mounting bracket placements on the DMX shelf.
Figure D-5 Mounting Bracket Positions on DMX Shelf
Equipment Compartment
The DMXtend and DMXplore rack mount shelves offer the same mounting bracket as DMX. The mounting brackets can be placed differently depending on customer requirements (6, 5, or 8 inches back from the front of the shelf).
All doors, covers and faceplates that are part of the Metropolis
®
DMX systems design shall be in place when installed in the cabinet to minimize losses in cooling and maximize resistance to electromagnetic interference. Apparatus Blanks (see engineering drawings
5
) are ordered separately from the shelf and shall be used where no circuit packs are installed.
Splicing Compartment
Cable access ports shall be provided in the base of the splicing compartment to permit the entrance of metallic and fiber cables into the equipment. Ports shall be sized to allow cables to be placed in accordance with minimum bend radii guidelines, as specified by the cable supplier.
Battery Compartment
If a battery compartment is provided, it shall be segregated from the electronics compartment. A seal shall be provided to prevent gases from seeping into the electronics and splicing compartments. The compartment shall be vented to the outside.
............................................................................................................................................................................................................................................................
365-372-324
Issue 4.2, April 2006
D - 7
Physical Requirements
Appendix D
Air Flow Air Flow Capacity
The fan unit shall supply a sufficient volume of air to cool the
Metropolis
®
DMX equipment whether using DMX internal fans or cabinet-level cooling equipment (it is required that Metropolis
®
DMX internal fan units be removed when installing the DMX, DMXtend, and
DMXplore in OSP environments). The amount of air required shall be based upon the environmental conditions and the self heating rates of the electronic equipment. An air mover shall be functional whenever circuit packs are in operation including during equipment AC power outages.
Refer to Environmental Requirements and Objectives: page D-15 for
thermal performance requirements.
Inlet/Exhaust
DMX requires air to enter the bottom of the shelf, flow vertically upward and exhaust at the top (and rear if an integrated baffle is used).
This direction of flow shall be provided to properly cool the circuit packs installed in the shelf.
DMXtend and DMXplore rack mount shelves require that air enters at the right of the shelf and exhausts on the left. The placement of these shelves should minimize blockage of vertical airflow. DMXtend can also be vertically mounted with the fan unit at the bottom of the shelf, allowing vertical airflow.
The DMXplore Wall-mount shelf is convection cooled.
The fan filter must be removed for all Metropolis
®
DMX shelves in all cabinets (the heat baffle must also be removed on the DMX shelf). If the cabinet fan can guarantee at least 200 LFM (linear feet per minute) through the shelf, then the internal fan is not needed. It is recommended that the fan be removed in these instances, and used as a spare for non
OSP deployments throughout your network.
Cable and Connector
Interfaces
Cable Placement and Routing
Refer to the Metropolis
®
DMX product’s respective Installation
Manuals
6 for cable placement and routing information. Cables shall be routed in accordance with the guidelines provided in the Installation
Manuals. Circuit pack cables shall be routed with half of the total number of cables from each side of the shelf.
...........................................................................................................................................................................................................................................................
D - 8
365-372-324
Issue 4.2, April 2006
Physical Requirements
Appendix D
Cable Routing
Cable shall be rated for a minimum temperature of 80 o
C.
Connector Contacts
All connector contacts that mate to Metropolis
®
DMX equipment shall be of similar contact finishes. Lucent Technologies recommends the use of gold with a minimum of 30 micro-inches.
Installation and
Maintenance
Engineering and Interconnection drawings shall be made available to
Lucent Technologies upon request.
............................................................................................................................................................................................................................................................
365-372-324
Issue 4.2, April 2006
D - 9
Appendix D
Electrical Requirements and Objectives
............................................................................................................................................................................................................................................................
Overview of
Power Requirements
The power consumption of the Metropolis
®
DMX products is dependent on the circuit packs installed and their operating state. These variables must be taken into account when sizing the power system.
DMX Power supply
The following table lists DMX shelf power requirements.
Table D-2 DMX Shelf Power Supply Requirements
Item
Voltage range
Power Feeders
Description
-40.0V to -60.0V
two -48V power feeders
[BREAKER (A) and BREAKER (B)]
Circuit Breakers (two per shelf) 30.0 A
The following table lists DMX 20 Amp shelf power requirements.
Table D-3 DMX 20 Amp High Capacity Shelf Power Supply
Requirements
Item
Voltage range
Power Feeders
Description
-40.0V to -60.0V
two -48V power feeders
[BREAKER (A) and BREAKER (B)]
Circuit Breakers (two per shelf) 20.0 A
...........................................................................................................................................................................................................................................................
D - 1 0
365-372-324
Issue 4.2, April 2006
Electrical Requirements and Objectives
Appendix D
DMX Current drains
The following table provides the maximum current drain requirements for a shelf.
Table D-4 DMX Shelf Current Drains
Shelf
DMX Shelf (20 Amp)
DMX Shelf (30 Amp)
Current Drains per Feeder in
Amperes
Maximum
@
−
48V
14.5
Maximum
@
−
40V
17.5
23.0
27.5
............................................................................................................................................................................................................................................................
365-372-324
Issue 4.2, April 2006
D - 1 1
Electrical Requirements and Objectives
Appendix D
DMXtend Power supply
The table below lists DMXtend power requirements.
Table D-5 DMXtend Power Supply Requirements
Item
Voltage range
Power Feeders
Circuit Breakers
Description
-40.0 VDC to -57.0 VDC two -48V power feeders
[BREAKER (A) and BREAKER (B)]
10.0A
DMXtend Current drains
The following table provides the maximum current drain requirements for a shelf.
Table D-6 DMXtend Shelf Current Drains
Shelf
DMXtend Shelf
Current Drains per Feeder in Amperes
Maximum
@
−
48V
7.1
Maximum
@
8.5
−
40V
...........................................................................................................................................................................................................................................................
D - 1 2
365-372-324
Issue 4.2, April 2006
Electrical Requirements and Objectives
Appendix D
DMXplore Power supply
The table below lists DMXplore power requirements.
Table D-7 DMXplore Power Supply Requirements
Item
Voltage range
Power Feeders
Circuit Breakers
Description
-40 to -57 volts
-48VDC (A and B)
Two, 2A fuses
DMXplore Current drains
The following table provides the maximum current drain requirements for a shelf.
Table D-8 DMXplore Shelf Current Drains
Shelf Current Drains per Feeder in Amperes
List 1
Maximum
@
−
48V
1.25 Amps
List 2
Maximum @
−
40V
1.5 Amps DMXplore Shelf
Power Quality
Metropolis
®
DMX products require a reliable low noise power source in accordance with GR-947
8
. This is usually accomplished by float charging batteries at the input to the Metropolis
®
DMX shelves.
Batteries are installed to provide back up power in the event of AC power outages. When deployed in a float charge configuration they also provide filtering of AC power line drop outs and noise generated by equipment in the cabinet. In all cases power must be configured to avoid dropping below or exceeding the voltage limits listed in the tables above.
Electrical Noise
Care must be taken to insure that electrical noise generated by the power system, fans, or other equipment does not interfere with the operation of the Metropolis
®
DMX products. Electrical noise on the –
48 volt power lines at the shelf must not exceed the voice frequency and wide-band noise limits in accordance with GR-947.
Interruptions
Momentary AC power line interruptions are accommodated by the batteries on float charge.
............................................................................................................................................................................................................................................................
365-372-324
Issue 4.2, April 2006
D - 1 3
Electrical Requirements and Objectives
Appendix D
Inrush Current
While there is no requirement to limit the rate of power application to the Metropolis
®
DMX shelves, the voltage at the shelf must remain within the specified limits at all times.
Battery Backup
In all cases battery backup power must be configured to avoid dropping
below the voltage limits listed between Table D-2 on page 10 and
Table D-8 on page 13. The preferred method of battery backup is a
float charge configuration. Alternatively, a separate battery and charger system can be used utilizing a diode “OR” configuration. Systems employing transfer switches are not recommended unless sufficient capacitance is installed to carry the system over through the transfer period.
Alarm Interfaces Cooling System Failure
A system failure alarm shall be provided for cabinet cooling systems with forced air ventilation and other heat exchanger systems
Grounding and Bonding
High Temperature
A temperature sensor shall be located in the electrical equipment compartment to provide a high temperature alarm when an internal cabinet temperature of 65 o
C is reached. The air temperature shall be measured at the inlet of the upper-most Metropolis
®
DMX shelf.
Grounding must meet the appropriate Telcordia
1
, UL
3
, and NEC
10 requirements for outside plant and customer premises applications. The
Metropolis
®
DMX shelves require a single common ground reference.
The Metropolis
®
DMX shelf frame must be bonded to an earth ground within the cabinet. Metropolis
®
DMX shelf mounting screws should be used to provide a low impedance multipoint electrical connection through the mounting structure to earth ground. A frame ground wire located on the shelf shall be connected to the cabinet ground.
I/O Protection
The DS3 interfaces (traffic ports) or other metallic telecom interfaces shall not leave the cabinet unless connected to telecom devices providing primary and secondary protection, as per GR-1089 and UL-
60950
3
(not applicable for Ethernet packs).
...........................................................................................................................................................................................................................................................
D - 1 4
365-372-324
Issue 4.2, April 2006
Appendix D
Environmental Requirements and Objectives
............................................................................................................................................................................................................................................................
Physical Strength Vibration
The cabinet shall be resistant to continuous low level vibrations from sources including train and vehicular traffic, rotating machinery, construction activities, etc. Physical tests shall be performed to assure the cabinet does not amplify vibrations from these sources such that the vibration levels transmitted to the equipment do not exceed design limits. Tests shall be performed in accordance with GR-487 and GR-63 to verify the performance of the cabinet and equipment during vibratory test conditions.
Thermal Operating
Temperature
Operating Temperature Range
Inlet air to the Metropolis
®
DMX equipment shall be controlled within the range of -40°C to +65°C. Ambient air from outside the cabinet cannot be introduced into the electronics compartment or used in any way to directly cool the Metropolis
®
DMX equipment within the cabinet.
Heat exchange systems for cabinet shall be sized so that maximum inlet temperature will not exceed 65°C even when the shelf is equipped in such a way that it approaches the maximum current drains detailed in
Table D-4 DMX Shelf Current Drains, Table D-6 DMXtend Shelf
Current Drains, and Table D-8 DMXplore Shelf Current Drains. Also,
the cabinet shall be sized to ensure that inlet temperature shall not exceed 65 o
C given both severe outside ambient temperature and solar heating relative to the conditions of the region where the shelf is deployed.
The supplier shall supply performance data upon request for cabinets cooled by compact heat exchangers or any other method. This information may include the appropriate factor of safety, or excess capacity, accounting for normal fouling of the heat exchanger core.
During operation, the time rate of change of the internal air temperature shall not exceed 30°C/hr as the result of solar heating and radiation cooling of the enclosure, and power cycling the equipment.
............................................................................................................................................................................................................................................................
365-372-324
Issue 4.2, April 2006
D - 1 5
Environmental Requirements and Objectives
Appendix D
Air Velocity
The self-heating of the Metropolis
®
DMXtend Access Multiplexer
DMX is dissipated primarily by forced convection cooling as the result of air blowing vertically between the parallel circuit cards. When DMX is deployed in OSP cabinets, the air flow (provided by cabinet fans) shall be no less than 300 LFM (Linear Feet per Minute).
The self-heating of the Metropolis
®
DMXtend and DMXplore Rackmount is dissipated primarily by forced convection cooling as the result of air blowing horizontally between the parallel circuit cards. Air flow for the DMXtend and DMXplore Rack-mount shelves is provided by fans inside the shelves themselves. Still, it is important that the air flow caused by cabinet fans not be at such a velocity that it impedes the proper functioning of the DMXtend and DMXplore shelf fans. The
DMXtend requires an airflow of no less than 200 LFM. The DMXplore requires a minimum airflow of 100 LFM.
The DMXplore Wall-mount shelf is convection cooled.
Cabinet Condensation
The relative humidity of the internal air of an outside cabinet shall be maintained in accordance with GR-63. This applies even when the equipment within the cabinet is in an unpowered condition, e.g., during installation of equipment. During such times a source of heat, or desiccant packs, shall be provided for maintaining the necessary relative humidity level.
...........................................................................................................................................................................................................................................................
D - 1 6
365-372-324
Issue 4.2, April 2006
Appendix D
Test Verification and Qualification
............................................................................................................................................................................................................................................................
Overview
Metropolis
®
DMXtend Access Multiplexer equipment shall be installed in cabinets that have demonstrated compliance in accordance with GR-487 and all other specifications as required by this document.
A cabinet that does not meet the requirements of this specification will negatively affect the performance, reduce service life, and threaten service continuity of any Metropolis
®
DMXtend Access Multiplexer system.
Compliance Reports covering cabinet performance to these specifications shall be made available to Lucent Technologies upon request.
System Thermal
Performance Verification
For the fully equipped cabinet configuration, a functional test of the
Metropolis
®
DMXtend Access Multiplexer shelf shall be performed with all systems powered at their appropriate levels for typical service applications that approach the maximum current drains detailed in
Table D-4 DMX Shelf Current Drains, Table D-6 DMXtend Shelf
Current Drains, and Table D-8 DMXplore Shelf Current Drains. The
cabinet surfaces shall be respectively heated at the appropriate maximum solar radiation levels. Absorbed solar heating shall be estimated using the formulations and methods in accordance with GR-
487 and the ASHRAE handbook
11
.
During this testing measure, record, and provide upon request:
• Power level into the cabinet in amperes
• Air Velocities in the airflow channels formed by the Metropolis
®
DMX, DMXtend, and DMXplore circuit packs in linear ft/min.
• Air temperature entering and exhausted from the Metropolis
®
DMXtend Access Multiplexer shelf (°C)
Three K or T type thermocouples shall be added at the inlet and exhaust of all circuit pack slots.
Take the average of the three thermocouples for each circuit pack slot for both inlet and exhaust and record (Tinlet_avg,
Texhaust_avg, TC type, and slot number).
• Ambient temperature (temperature outside the cabinet and measured in °C).
• Solar heating loads on respective cabinet surfaces (°C).
............................................................................................................................................................................................................................................................
365-372-324
Issue 4.2, April 2006
D - 1 7
Appendix D
References
............................................................................................................................................................................................................................................................
1)
Telcordia Document — Network Equipment - Building System
(NEBS) Requirements: Physical Protection, GR-63, Issue 2, April
2002.
2)
Telcordia Document — Electromagnetic Compatibility and Electrical
Safety - Generic Criteria for Network Telecommunications Equipment,
GR-1089, Issue 3, October 2002.
3)
UL 60950/ CAN/CSA- 22.2 NO. 60950-00 “Safety of Information
Technology Equipment”, December, 2000
4)
Telcordia Document — Generic Requirements for Electronic
Equipment Cabinets, GR-487, Issue 2, March 2000.
5)
Lucent Technologies Document — DMX Access Multiplexer
Engineering Drawing, ED8C871-10, Latest Issue.
Lucent Technologies Document — DMXtend Access Multiplexer
Engineering Drawing, ED8C951-10, Latest Issue.
Lucent Technologies Document — DMXplore Access Multiplexer
Engineering Drawing, ED8C947-10, Latest Issue.
6)
Lucent Technologies Document — DMX Access Multiplexer
Installation Manual, 365-372-300, Latest Issue.
Lucent Technologies Document — DMXtend Access Multiplexer
Installation Manual, 365-372-327, Latest Issue.
Lucent Technologies Document — DMXplore Access Multiplexer
Installation Manual, 365-372-334, Latest Issue.
7)
Lucent Technologies Document — DMX Access Multiplexer
Applications and Planning Guide, 365-372-300, Latest Issue.
Lucent Technologies Document — DMXtend Access Multiplexer
Applications and Planning Guide, 365-372-324, Latest Issue.
Lucent Technologies Document — DMXplore Access Multiplexer
Applications and Planning Guide, 365-372-331, latest Issue.
8)
Telcordia Document — Generic Requirements for a –48 volt
Telecommunications Switchmode Rectifier/ Power Supply, GR-947,
Issue 1, December 1996.
...........................................................................................................................................................................................................................................................
D - 1 8
365-372-324
Issue 4.2, April 2006
References
Appendix D
9)
Lucent Technologies Document — Metropolis
®
DMXtend Access
Multiplexer Access System Engineering Guidelines, TBS, Latest Issue.
10)
National Fire Protection Agency (NFPA-70), National Electrical Code
(NEC), 2002 Edition.
11)
2001 ASHRAE Handbook Fundamentals — American Society of
Heating, Refrigerating and Air Conditioning Engineers, Inc., Atlanta
GA.
............................................................................................................................................................................................................................................................
365-372-324
Issue 4.2, April 2006
D - 1 9
References
Appendix D
...........................................................................................................................................................................................................................................................
D - 2 0
365-372-324
Issue 4.2, April 2006
Glossary
Acronyms and Abbreviations
............................................................................................................................................................................................................................................................
1G
Gigabit
............................................................................................................................................................................................................................................................
A ABN
Abnormal (status condition)
ACO
Alarm Cutoff
ACO/SW
Alarm Cutoff and Test
ADR
Add/Drop Ring
AGNE
Alarm Gateway Network Element
ADM
Add/Drop Multiplexer
AIS
Alarm Indication Signal
AMI
Alternate Mark Inversion
ANSI
American National Standards Institute
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
G L O S S A R Y
G L - 1
APS
Automatic Protection Switch
ARM
Access Resource Manager
AS&C
Alarm, Status, and Control
ASCII
American Standard Code for Information Interchange
ASN.1
Abstract Syntax Notation 1
ASNE
Alarm Server Network Element
ATM
Asynchronous Transfer Mode
Auto
Automatic
AUXCTL
Auxiliary Control
............................................................................................................................................................................................................................................................
B B3ZS
Bipolar 3-Zero Substitution
B8ZS
Bipolar 8-Zero Substitution
BDFB
Battery Distribution and Fuse Bay
BER
Bit Error Ratio
BIP
Bit Interleaved Parity
.........................................................................................................................................................................................................................................................
G L O S S A R Y
G L - 2
365-372-300
Issue 8.0 September 2006
BITS
Building Integrated Timing Supply
BLSR
Bidirectional Line Switched Ring
BPDU
Bridge Protocol Data Unit
BRI
Basic Rate Interface
............................................................................................................................................................................................................................................................
C CC
Clear Channel
CCITT
Comité ConsultatifInternational Télégrafique & Téléphonique
International Telephone and Telegraph Consultative Committee
CEV
Controlled Environment Vault
CD-ROM
Compact Disk, Read-Only Memory
CDTU
Channel and Drop Test Unit
CIT
Craft Interface Terminal
CLEC
Competitive Local Exchange Carrier
CLEI
Common Language Equipment Identifier
CLF
Carrier Line Failure Status
CLK
Clock
...........................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
G L O S S A R Y
G L - 3
CMISE
Common Management Information Service Element
CMTS
Cable Modem Termination System
CO
Central Office
CP
Circuit Pack
CPE
Customer Premises Equipment
CR
Critical (alarm status)
CSF
Client Signal Fail
CSU
Channel Service Unit
CTL
Control
CTS
Customer Technical Support; now known as Technical Support Services (TSS)
CV
Coding Violation
CVFE
Coding Violation Far End
............................................................................................................................................................................................................................................................
D DACS
Data Access Cross-connect System
dB
Decibels
.........................................................................................................................................................................................................................................................
G L O S S A R Y
G L - 4
365-372-300
Issue 8.0 September 2006
DC
Direct Current
DCC
Data Communications Channel
DCE
Data Communications Equipment
DCS
Data Collection System
DEMUX
Demultiplexer
DLC
Digital Loop Carrier
DNS
Data Networking Services
DPLL
Digital Phase-Locked Loop
DRI
Dual Ring Interworking
DS1
Digital Signal Level 1
DS3
Digital Signal Level 3
DSL
Digital Subscriber Line
DSLAM
Digital Subscriber Line Access Multiplexer
DSNE
Directory Services Network Element
DSX
Digital Cross-Connect Panel
...........................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
G L O S S A R Y
G L - 5
DT
Distant Terminal
DTE
Data Terminating Equipment
DWDM
Dense Wave Division Multiplexing
............................................................................................................................................................................................................................................................
E EC-1
Electrical Carrier Level 1
ECI
Equipment Catalog Item
EEPROM
Electrically-Erasable Programmable Read-Only Memory
EIA
Electronic Industries Association
EMC
Electromagnetic Compatibility
EMI
Electromagnetic Interference
EOOF
Excessive Out of Frame
EPORT
Ethernet Port
EPROM
Erasable Programmable Read-Only Memory
EQ
Equipped (memory administrative state)
EQPT
Equipment
.........................................................................................................................................................................................................................................................
G L O S S A R Y
G L - 6
365-372-300
Issue 8.0 September 2006
ES
Errored Seconds
ESCON
Enterprise Systems Connection
ESD
Electrostatic Discharge
ESF
Extended Super Frame
EST
Environmental Stress Testing
............................................................................................................................................................................................................................................................
F FC
Fibre-Channel
FC-1G
Fibre-Channel - 1 Gbps
FC-2G
Fibre-Channel - 2 Gbps
FCC
Federal Communications Commission
FDDI
Fiber Distribution Data Interface
FE
Far End
FE ACTY
Far End Activity
FEBE
Far End Block Error
FEC
Forward Error Correction
...........................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
G L O S S A R Y
G L - 7
FE ID
Far End Identification
FEPROM
Flash EPROM
FERF
Far End Receive Failure
FE SEL
Far End Select
FICON
Fibre Connection
FIT
Failures in 10
-9
hours of operation.
FTAM
File Transfer and Access Management
FTP
File Transfer Protocol
FTTD
File Transfer Translation Device
............................................................................................................................................................................................................................................................
G GB
Gigabytes
Gb/s or Gbps
Gigabits per Second
GbE
Gigabit Ethernet
GHz
Gigahertz
GNE
Gateway Network Element
GR-XXX
Telcordia Technologies (Bellcore) General Requirement-XXX
.........................................................................................................................................................................................................................................................
G L O S S A R Y
G L - 8
365-372-300
Issue 8.0 September 2006
GTP
General Telemetry Processor
GUI
Graphical User Interface
............................................................................................................................................................................................................................................................
H HECI
Humans Equipment Catalog Item
HFC
Hybrid Fiber Coaxial
HS
High Speed
Hz
Hertz
............................................................................................................................................................................................................................................................
I IAO LAN
Intra-Office Local Area Network
IC
Internal Clock
ID
Identifier
IEC
International Electrotechnology Commission
IEEE
Institute of Electrical and Electronics Engineers
IMF
Infant Mortality Factor
INC
Incoming Status
I/O
Input/Output
...........................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
G L O S S A R Y
G L - 9
IP
Internet Protocol
IR
Intermediate Reach
IS
In Service
ISCI
Intershelf control Interface
ISI
Intershelf Interface
ISDN
Integrated Services Digital Network
ISO
International Standards Organization
ISP
Internet Service Provider
............................................................................................................................................................................................................................................................
K Kb/s
Kilobits per second
............................................................................................................................................................................................................................................................
L LAN
Local Area Network
LAPD
Link Access Procedure "D"
LBC
Laser Bias Current
LBO
Line Build Out
LCN
Local Communications Network
.........................................................................................................................................................................................................................................................
G L O S S A R Y
G L - 1 0
365-372-300
Issue 8.0 September 2006
LEC
Local Exchange Carrier
LED
Light-Emitting Diode
LFD
Loss of Frame Delineation
LGX
Lightguide Cross-Connect
LOA
Loss of Alignment
LOF
Loss of Frame
LOP
Loss of Pointer
LOS
Loss of Signal
LR
Long Reach
LS
Low Speed
............................................................................................................................................................................................................................................................
M MB
Megabytes
Mb/s
Megabits per second
MJ
Major Alarm
MM
Multimode
...........................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
G L O S S A R Y
G L - 1 1
MML
huMan-Machine Language
MN
Minor Alarm
MPEG
Moving Picture Experts Group
MSDT
Multi-Services Distant Terminal
MSO
Metropolitan Serving Office
MTBF
Mean Time Between Failures
MTBMA
Mean Time Between Maintenance Activities
Mult
Multipling
MUX
Multiplex
............................................................................................................................................................................................................................................................
N NA
Not Applicable
NAP
Network Access Point
NE
Near End
NE
Network Element
NE ACTY
Near-End Activity
.........................................................................................................................................................................................................................................................
G L O S S A R Y
G L - 1 2
365-372-300
Issue 8.0 September 2006
NEBS
Network Equipment-Building System
nm
Nanometer (10
-9
meters)
NMA
Network Monitoring and Analysis
NMON
Not Monitored (provisioning state)
NR
Not Reported
NRZ
Nonreturn to Zero
NNI
Network-Network Interface
NSA
Not Service Affecting
NSAP
Network Services Access Point
NTF
No Trouble Found
NTP
Network Time Protocol
NUT
Nonpreemptible unprotected traffic
NTF
Non-Volatile Memory
............................................................................................................................................................................................................................................................
O OAM&P
Operations, Administration, Maintenance, and Provisioning
...........................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
G L O S S A R Y
G L - 1 3
OC-1
Optical Carrier Level 1 Signal (51.84 Mb/s)
OC-192
Optical Carrier Level 192 Signal (9953 Mb/s)
OC-3
Optical Carrier Level 3 Signal (155 Mb/s)
OC-12
Optical Carrier Level 12 Signal (622 Mb/s)
OC-48
Optical Carrier Level 48 Signal
OI
Operations Interworking
OLIU
Optical Line Interface Unit
OOF
Out of Frame
OOL
Out of Lock
OOS
Out-of-Service
OPS/INE
Operations System/Intelligent Network Element
OS
Operations System
OSGNE
Operations System Gateway Network Element
OSI
Open Systems Interconnection
OSMINE
Operations Systems Modifications for the Integration of Network Elements
.........................................................................................................................................................................................................................................................
G L O S S A R Y
G L - 1 4
365-372-300
Issue 8.0 September 2006
OSP
Outside Plant
............................................................................................................................................................................................................................................................
P P-bit
Performance Bit
PC
Personal Computer
PCU
Power Conversion Unit
PID
Program Identification
PIR
Peak Information Rate
PINFET
Positive Intrinsic Negative Field Effect Transistor
PJC
Pointer Justification Count
PLL
Phase-Locked Loop
PM
Performance Monitoring
PMN
Power Minor Alarm
POH
Path Overhead
POP
Points of Presence
POTS
Plain Old Telephone Service
...........................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
G L O S S A R Y
G L - 1 5
PRM
Performance Report Message
PROTN
Protection
PRS
Primary Reference Source
PSU
Power Supply Unit
PTM
Pluggable Transmission Module, also known as SFP
PVC
Permanent Virtual Circuit
PWR
Power
............................................................................................................................................................................................................................................................
Q QoS
Quality of Service
............................................................................................................................................................................................................................................................
R RAM
Random Access Memory
RDC
Regional Data Center
RDI
Remote Defect Indication
RFI
Remote Failure Indication
RPP
Reliability Prediction Procedure (described in Telcordia Technologies TR-NWT-
00032)
RT
Remote Terminal
.........................................................................................................................................................................................................................................................
G L O S S A R Y
G L - 1 6
365-372-300
Issue 8.0 September 2006
RTRV
Retrieve
RU
Rack Unit
RZ
Return to Zero
............................................................................................................................................................................................................................................................
S SA
Service Affecting
SAN
Storage Area Networking
SD
Signal Degrade
SDH
Synchronous Digital Hierarchy
SEFS
Severely Errored Frame Seconds
SEO
Single-Ended Operations
SES
Severely Errored Seconds
SF
Super Frame (format for DS1 signal)
SID
System Identification
SLA
Service Level Agreements
SM
Single Mode
...........................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
G L O S S A R Y
G L - 1 7
SMC
SONET Minimum Clock
SNMP
Simple Network Management Protocol
SONET
Synchronous Optical NETwork
SPE
Synchronous Payload Envelope
SQU
Sync Quality Unknown
SRD
Software Release Description
STS, STS-n
Synchronous Transport Signal
STM
Synchronous Transfer Mode
STS-1 SPE
STS-1 Synchronous Payload Envelope
STS-3c
Synchronous Transport Level 3 Concatenated Signal
STS-12c
Synchronous Transport Level 12 Concatenated Signal
STS-48c
Synchronous Transport Level 48 Concatenated Signal
STU
Synchronized - Traceability Unknown
SYSCTL
System Controller (circuit pack)
.........................................................................................................................................................................................................................................................
G L O S S A R Y
G L - 1 8
365-372-300
Issue 8.0 September 2006
............................................................................................................................................................................................................................................................
T T1
A carrier system that transmits at the rate of 1.544 Mb/s (a DS1 signal)
T1X1 and T1M1
The ANSI committees responsible for telecommunications standards
T3
A carrier system that transmits at the rate of 44.736 Mb/s (a DS1 signal)
TA
Telcordia Technologies Technical Advisory
TABS
Telemetry Asynchronous Byte Serial (Protocol)
TARP
Target ID Address Resolution Protocol
TBD
To be Determined
TCA
Threshold-Crossing Alert
TCP/IP
Transmission Control Protocol/Internet Protocol
TCVCXO
Termperature-Compensated Voltage-Controlled Crystal Oscillator
TDC
TARP Date Cache
TDM
Time Division Multiplexing
THz
Terahertz (10
12
Hz)
TID
Target Identifier
...........................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
G L O S S A R Y
G L - 1 9
TIRKS
Trunk Integrated Record Keeping System
TG3
Stratum 3 Timing Generator
TL1
Transaction Language 1
TR
Telcordia Technologies Technical Requirement
TSA
Time Slot Assignment
TSI
Time Slot Interchange
TSO
Technical Support Organization
............................................................................................................................................................................................................................................................
U UAS
Unavailable Seconds
UNI
User Network Interface
UOC
Universal Optical Connector
UPD/INIT
Update/Intialize
UPSR
Unidirectional Path Switched Rings
............................................................................................................................................................................................................................................................
V VAC
Volts Alternating Current
VCG
Virtual Concatenation Group
.........................................................................................................................................................................................................................................................
G L O S S A R Y
G L - 2 0
365-372-300
Issue 8.0 September 2006
VCG FE
Virtual Concatenation Group - Fast Ethernet
VDC
Volts Direct Current
VLAN
Virtual Local Area Network
VM
Violation Monitor
VMR
Violation Monitor and Removal
VoIP
Voice over Internet Protocol
VONU
Virtual Optical Network Unit
VPN
Virtual Private Network
vslot
Virtual Slot
VT
Virtual Tributary
VT1.5
Virtual Tributary 1.5 (1.728 Mb/s)
VT-G
Virtual Tributary Group
............................................................................................................................................................................................................................................................
W WAN
Wide Area Network
WDM
Wave Division Multiplexing
...........................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
G L O S S A R Y
G L - 2 1
WTR
Wait To Restore
.........................................................................................................................................................................................................................................................
G L O S S A R Y
G L - 2 2
365-372-300
Issue 8.0 September 2006
Glossary
Terms and Definitions
............................................................................................................................................................................................................................................................
0x1Sn
DMX provides an unprotected 0x1Sn mode. This option is userprovisionable on a per-port basis. 0x1S1 and 0x1S2 are provisionable applications for LS OC-n port pairs. For 0x1S1, the port in slot 1 is unprotected and the companion port in slot 2 is unused. For 0x1S2, the port in slot 2 is unprotected and the companion port in slot 1 is unused.
1+1 (bidirectional)
The bidirectional 1+1 protection switching architecture protects against failures of the optical transmit/receive equipment and their connecting fiber facility. One bidirectional interface (two fibers plus associated OLIUs on each end) is designated
″ service,
″ and the other is designated
″ protection.
″
In each direction, identical signals are transmitted on the service and protection lines (
″ dual-fed
″
). The receiving equipment monitors the incoming service and protection lines independently, and selects traffic from one line (the
″ active
″ line) based on performance criteria and technician/OS control. In bidirectional 1+1 only one line is active at a time.
1+1 (unidirectional)
The unidirectional 1+1 protection switching architecture protects against failures of the optical transmit/receive equipment and their connecting fiber facility. One bidirectional interface (two fibers plus associated OLIUs on each end) is designated
″ service,
″ and the other is designated
″ protection.
″
In each direction, identical signals are transmitted on the service and protection lines (
″ dual-fed
″
). The receiving equipment monitors the incoming service and protection lines independently, and selects traffic from one line (the
″ active
″ line) based on performance criteria and technician/OS control. In unidirectional 1+1 both service and protection lines could be active at the same time (service in one direction, protection in the other).
1xN, 1x1
1xN protection switching pertains to circuit pack protection that provides a redundant signal path through the DMX (it does not cover protection switching of an optical facility; see "1+1"). In 1xN switching, a group of N service circuit packs share a single spare protection circuit pack. 1x1 is a special case of 1xN, with N=1.
............................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
G L O S S A R Y
G L - 2 3
In 1x1 only one is active at a time.
802.1Q mode
In 802.1Q Mode, a circuit pack can be provisioned to use an incoming frame’s VLAN tag, to add a VLAN tag associated with the port for untagged frames, or to drop an incoming frame if its
VLAN tagging does not meet provisioned specifications. The priority bits in an incoming frame’s
VLAN tag can also be used to affect the handling of the frame.
............................................................................................................................................................................................................................................................
A Active
Active identifies a 1+1 protected entity which is currently selected by the receiver at either end as the payload carrying signal or a 1x1 or 1xN protected circuit pack that is currently carrying service. (See Standby).
Adaptive Rate
(see Pipe Mode).
Add/Drop Multiplexer
The term for a sychronous network element capable of combining signals of different rates and having those signals added to or dropped from the stream.
AGNE - Alarm Gateway Network Element
A defined NE in an alarm group through which members of the alarm group exchange information.
Aging (Ethernet MAC Address)
The filtering database entries are automatically removed after an aging period (300 seconds).
AIS - Alarm Indication Signal
A code transmitted downstream in a digital network that shows that an upstream failure has been detected and alarmed.
Alarm
Visible or Audible signal indicating that an equipment failure or significant event/ condition has occured.
Alarm Cut-Off (ACO)
A button on the SYSCTL used to silence audible alarms. Alarms can also be silenced using the
Fault
→
Alarm Cutoff
command.
AMI - Alternate Mark Inversion
A line code that employs a ternary signal to convey binary digits, in which successive binary ones are represented by signal elements that are normally of
.........................................................................................................................................................................................................................................................
G L O S S A R Y
G L - 2 4
365-372-300
Issue 8.0 September 2006
alternating, positive and negative polarity but equal in amplitude, and in which binary zeros are represented by signal elements that have zero amplitude.
APS Channel
The signaling channel carried in the K1 and K2 bytes of the SONET overhead on the protection line. It is used to exchange requests and acknowledgments for protection switch actions.
ASCII - American Standard Code for Information Interchange
A standard 8-bit code used for exchanging information among data processing systems and associated equipment.
Auto
One possible state of a DS1 or DS3 port. In this state, the port will automatically be put "in service" if a good signal is detected coming from the DSX panel.
Automatic Protection Switch
A feature that allows any entity to be automatically selected and the provisioning to be automatically reconfigured in the event of a failure or network change, for example, a fiber cut.
Autonomous Message
A message transmitted from the controlled Network Element to the ITM-SC which was not a response to an ITM-SC originated command.
Available Time
In performance monitoring, the 1-second intervals.
............................................................................................................................................................................................................................................................
B B3ZS - Bipolar 3-Zero Substitution
A line coding method that replaces a string of three zeros with a sequence of symbols having some special characteristic.
B8ZS - Bipolar 8-Zero Substitution
A line coding method that replaces a string of eight zeros with a sequence of symbols having some special characteristic.
Backbone Ring
A host ring.
Backup
The backup and restoration features provide the capability to recover from loss of NE data because of such factors as human error or power failures.
...........................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
G L O S S A R Y
G L - 2 5
Bandwidth
The difference in Hz between the highest and lowest frequencies in a transmission channel. The data rate that can be carried by a given communications circuit.
Baud Rate
Transmission rate of data (bits per second) on a network link.
BER - Bit Error Rate
The ratio of bits received in error to the total bits sent.
Bidirectional Line
A transmission path consisting of two fibers that handle traffic in both the transmit and receive directions.
Bidirectional Line Switched Ring (BLSR)
A bidirectional ring in which protection switching is accomplished by switching working traffic into protection time slots in the line going in the opposite direction around the ring.
Bidirectional Ring
A ring in which both directions of traffic between any two nodes travel through the same network elements (although in opposite directions).
Bidirectional Switch
Protection switching performed in both the transmit and receive directions.
BIP - Bit Interleaved Parity
A method of error monitoring over a specified number of bits, that is BIP-3 or BIP-
8.
BIT
The smallest unit of information in a computer, with a value of either 0 or 1.
BIT Error Rate (BER)
The ratio of error bits received to the total number of bits transmitted.
BIT Error Rate Threshold
The point at which an alarm is issued for bit errors.
BIT Interleaved Parity-N (BIP-N)
A method of error monitoring over a specified number of bits (BIP-3 or BIP-8).
BITS Clock
A BITS (Building Integrated Timing Source) clock is simply a clock within a central office that distributes timing to all the equipment in that central office. The BITS clock is tied to an
.........................................................................................................................................................................................................................................................
G L O S S A R Y
G L - 2 6
365-372-300
Issue 8.0 September 2006
external, stable timing source, such as a GPS (global positioning satellite).
BITS - Building Integrated Timing Supply
A single clock that provides all the DS1 and DS0 synchronization references required by clocks in a building.
Blocking
The state in which an Ethernet port does not participate in frame relay. The forwarding process discards received frames.
Bridge cross-connection
Two cross-connections which share a common input.
Broadband
Any communications channel with greater bandwidth than a voice channel; sometimes used synonomously with wideband.
Burst Size
The provisioned burst size determines the length or size of the data burst that is allowed by the peak information rate policer. This affects policing for all VLANs (in 802.1Q mode), all port tags (in transparent mode). and all Private line services (in Private Line or No Tag mode) on the
LNW63, LNW66, LNW67, LNW68, LNW70, LNW71, LNW74, and LNW78 Ethernet circuit packs.
Byte
Refers to a group of eight consecutive binary digits.
............................................................................................................................................................................................................................................................
C C-BIT
A framing format used for DS3 signals produced by multiplexing 28 DS1s into a DS3. This format provides for enhanced performance monitoring of both near-end and far-end entities.
CC - Clear Channel
A provisionable mode for the T3 interface used for the transport of unframed DS3 signals. Only near-end line PM is available, but not path PM.
CCITT - International Telephone and Telegraph Consultative Committee
An international advisory committee under United Nations’ sponsorship that has composed and recommended for adoption worldwide standards for international communications. Recently changed to the International Telecommunications
Union Telecommunications Standards Sector (ITU-TSS).
Channel
A logical signal within a port. For example, for an EC-1 port, there is one STS-1
...........................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
G L O S S A R Y
G L - 2 7
channel and sometimes 28 VT1.5 channels. See Port.
Channel State Provisioning
A feature that allows a user to suppress reporting of alarms and events during provisioning by supporting multiple states (automatic, in-service and not monitored) for VT1.5 and STS-1 channels. See Port State Provisioning.
Circuit
A set of transmission channels through one or more network elements that provides transmission of signals between two points, to support a single communications path.
CLEC - Competitive Local Exchange Carrier
Company that provides local phone services in competition with RBOCs.
Client Signal Fail
The local NE sends a Client Signal Fail (CSF) signal to the far-end equipment when a defect is detected in the ingress client signal.
Collocated
System elements that are located in the same location.
Concatenation
A procedure whereby multiple virtual containers are associated one with each other resulting in a combined capacity that can be used as a single container across which bit sequence integrity is maintained.
Constituent Signals
List of received signals for an adaptive rate (pipe mode) optical port.
Cost
Cost is used to help determine the efficiency of any given path. Cost is provisioned for a port
(depending on speed of transmission) and calculated automatically for a path (sum of the port costs for the path).
Craft Interface Terminal (CIT)
The user interface terminal used by craft personnel to communicate with a network element.
Credit Interval
The provisioned interval for adding tokens to the token bucket used by the peak information rate policer. This affects policing for all VLANs (in 802.1Q mode), all port tags (in transparent mode). and all Private line services (in Private Line or No Tag mode) on the
LNW63, LNW66, LNW67,
LNW68, LNW70, LNW71, LNW74, and LNW78
Ethernet circuit packs.
.........................................................................................................................................................................................................................................................
G L O S S A R Y
G L - 2 8
365-372-300
Issue 8.0 September 2006
Critical (CR)
Alarm that indicates a severe, service-affecting condition.
Cross-connect Capacity
The total bandwidth of cross-connections as measured by the bandwidth of input and output tributaries. A system with N STS-1 equivalent input tributaries and N STS-1 equivalent output tributaries (referred to as
″
NxN
″
) provides a cross-connection capacity of N STS-1 equivalents.
This system could provide N one-way point-to-point cross-connections or N/2 two-way point-to-point cross-connections at the equivalent rate of STS-1.
Cross-connect Rate
The attribute of a cross-connection that defines the constituent signal rate(s) it can carry. For a cross-connection with an STS-3
″ pipe
″ cross-connection rate, the constituent signals carried by the cross-connection can be either an STS-3c signal or three STS-3 signals. Similarly, for a cross-connection with an STS-12
″ pipe
″ cross-connection rate, the constituent signals carried by the cross-connection can be either an STS-12c signal or an allowed mix of STS-1 signals and
STS-3c signals.
Cut-Through
Refers to a simple ASCII interface to an NE. It enables the user to send TL1 messages directly to the NE with no interpretation or assistance provided by the WaveStar CIT.
CV - Coding Violation
A performance monitoring parameter.
CVFE - Coding Violation Far-End
An indication returned to the transmitting terminal that an errored block has been detected at the receiving terminal.
............................................................................................................................................................................................................................................................
D DACS III-2000
Digital Access and Cross-Connect System that provides clear channel switching at either the DS3 or the STS-1 rates, eliminating the need for manual DSXs.
DACS IV-2000
Digital Access and Cross-Connect System that provides electronic DS3/STS-1 or
DS1/VT1.5 cross-connect capability, eliminating the need for manual DSXs.
DCC - Data Communications Channel
The embedded overhead communications channel in the SONET line. It is used for end-to-end communications and maintenance. It carries alarm, control, and status information between network elements in a SONET network.
...........................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
G L O S S A R Y
G L - 2 9
DCE - Data Communications Equipment
In a data station, the equipment that provides the signal conversion and coding between the data terminal equipment (DTE) and the line. The DCE may be separate equipment or an integral part of the DTE or of intermediate equipment. A DCE may perform other functions usually performed at the network end of the line.
DTE - Data Terminating Equipment
The equipment that originates data for transmission and accepts transmitted data.
DDM-2000
Lucent’s next generation network multiplexers that multiplex DS1, DS3, or EC-1 inputs into EC-1, OC-1, OC-3, or OC-12 outputs.
Default Provisioning
The parameter values that are preprogrammed as shipped from the factory.
Demultiplexing
A process applied to a multiplexed signal for recovering signals combined within it and for restoring the distinct individual channels of these signals.
DEMUX - Demultiplexer
The DEMUX direction is from the fiber toward the DSX.
Dense Wave Division Multiplexing (DWDM)
Transmitting two or more signals of different wavelengths simultaneously over a single fiber.
Digital Cross-connect Panel
A panel designed to interconnect to equipment that operates at a designated rate. For example, a
DSX-3 interconnects equipment operating at the DS3 rate.
Digital Multiplexer
Equipment that combines time-division multiplexing several digital signals into a single composite digital signal.
Digital Signal Levels 0, 1, 3, (DS0, DS-1, DS-3)
An ANSI-defined signal or service level corresponding to the following: DS0 is 64 Kb/s, DS1 is
1.544 Mb/s (equivalent to T1), and DS3 is 44.736 Mb/s (equivalent to 28 T1 channels or T3).
Directory Services Network Element
A designated network element that is responsible for administering a database that maps network element names (TIDs) to addresses (NSAPs - network service access points) in an OSI subnetwork. There can be one DSNE per ring. Can also be a GNE.
.........................................................................................................................................................................................................................................................
G L O S S A R Y
G L - 3 0
365-372-300
Issue 8.0 September 2006
Disable admin
An Ethernet port that does not participate in the spanning tree. The port is disabled by management.
Disable failure
A port in this state does not participate in the spanning tree. The port is disabled due to a hardware or software failure.
DRI - Dual Ring Interworking
Two ring networks interconnected at two common nodes.
Drop and Continue
A technique that allows redundant signal appearances at two central offices in a
DRI network, allowing protection against central office failures.
DS1
Digital Signal Level 1 (1.544 Mb/s)
DS1(28) Circuit Pack
The DS1(28) circuit pack interfaces to the DSX-1 panel.
DS3
Digital Signal Level 3 (44.736 Mb/s).
DS3/EC-1 Circuit Pack
The DS3/EC-1 circuit pack interfaces to the DSX-3 panel.
DSn - Digital Signal Rate n
One of the possible digital signal rates at DMX 2.5G Multiplexer interfaces: DS1
(1.544 Mb/s) or DS3 (44.736 Mb/s).
DSNE - Directory Services Network Element
A designated network element that is responsible for administering a database that maps network element names (TIDs) to addresses (NSAPs - network service access points) in an OSI subnetwork. There can be one DSNE per ring. Can also be a GNE.
DSX - Digital Cross-Connect Panel
A panel designed to interconnect to equipment that operates at a designated rate.
For example, a DSX-3 interconnects equipment operating at the DS3 rate.
DTE - Data Terminating Equipment
That part of a data station that serves as a data source (originates data for transmission), a data sink (accepts transmitted data), or both.
...........................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
G L O S S A R Y
G L - 3 1
Dual Homing
A network topology in which two OC-3 or OC-12 shelves serve as DMX 2.5G
Multiplexer hosts supporting up to 16 OC-3 rings or 4 OC-12 rings. Each DMX
2.5G Multiplexer ring is interconnected between the two separate hosts.
............................................................................................................................................................................................................................................................
E E1
E1 is an SDH/PDH (Synchronous Digital Hierarchy/Pleiseosynchronous Digital Hierarchy, the
European equivalent of SONET/DSx) electrical signal comparable to (but slightly faster than) a
DS1. E1 is also sometimes called CEPT-1 (Conference of European Posts and Telecommunications) and is at 2.048 Mbps.
EC-1, EC-n - Electrical Carrier
The basic logical building block signal with a rate of 51.840 Mb/s for an EC-1 signal and a rate of n times 51.840 Mb/s for an EC-n signal. An EC-1 signal can be built in two ways: A DS1 can be mapped into a VT1.5 signal and 28 VT1.5 signals multiplexed into an EC-1 (VT1.5 based EC-1), or a DS3 can be mapped directly into an EC-1 (DS3 based EC-1).
ECI - Equipment Catalog Item
The bar code number on the faceplate of each circuit pack used by some inventory systems.
Electromagnetic Compatibility (EMC)
A measure of equipment tolerance to external electromagnetic fields.
Electromagnetic Interface (EMI)
High-energy, electrically induced magnetic fields that cause data corruption in cables passing through the fields.
Electronic Industries Association (EIA)
A trade association of the electronic industry that establishes electrical and functional standards.
Electrostatic Discharge (ESD)
Static electrical energy potentially harmful to circuit packs and humans.
ES - Errored Seconds
A performance monitoring parameter.
Enterprise Systems Connection (ESCON)
A 200-Mbps data signal used in storage area networking applications.
Event
A significant change. Events in controlled Network Elements include signal failures, equipment
.........................................................................................................................................................................................................................................................
G L O S S A R Y
G L - 3 2
365-372-300
Issue 8.0 September 2006
failures, signals exceeding thresholds, and protection switch activity. When an event occurs in a controlled Network Element, the controlled Network Element will generate an alarm or status message and send it to the management system.
The format for a DS1 signal.
Extended Super Frame (ESF)
A T1 format that uses the framing bit for non-intrusive signaling and control. A T1 frame is sent 8,000 times a second, with each frame consisting of a payload of 192 bits, and with each frame preceded by a framing bit. Because ESF only requires 2,000 framing bits for synchronization, the remaining 6,000 framing bits can be used for error detection.
Externally Timed
An operating condition of a clock in which it is locked to an external reference and is using time constants that are altered to quickly bring the local oscillator’s frequency into approximate agreement with the synchronization reference frequency.
Extra Traffic
Unprotected traffic that is carried over BLSR protection channels when their capacity is not used for the protection of working traffic. However, the extra traffic is unprotected and is preempted (lost) if a BLSR protection switch is activated. Preempted traffic is reestablished when the BLSR protection switch clears.
............................................................................................................................................................................................................................................................
F Facility
A one- or two-way circuit that carries a transmission signal.
Facility Loopback
A facility loopback is where an entire line is looped back.
Facility Roll
The process of moving the input of an existing cross-connection to a new input using a single command to the NE.
Failure in Time (FIT)
Circuit pack failure rates per 10
9 hours as calculated using the method described in Reliability
Prediction Procedure for Electronic Equipment, Telcordia Method I, Issue 5,
September 1995.
Fault
Term used when a circuit pack has a hard (not temporary) fault and cannot perform its normal function.
...........................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
G L O S S A R Y
G L - 3 3
Fault Management
Collecting, processing, and forwarding of autonomous messages from network elements.
FE - Far End
Any other network element in a maintenance subnetwork other than the one the user is at or working on. Also called remote.
FE ACTY - Far End Activity
An LED on the SYSCTL circuit pack faceplate.
FEBE - Far End Block Error
An indication returned to the near-end transmitting node that an errored block has been detected at the far end.
FE ID - Far End Identification
The 7-segment display on the faceplate of the SYSCTL (LNW1) circuit pack. The
LNW2, used for R6.0 and beyond, has an alphanumeric LED display that is labeled
IND.
FEPROM - Flash EPROM
A new technology that combines the nonvolatility of EPROM with the in-circuit reprogrammability of EEPROM (electrically-erasable PROM).
FERF - Far End Receive Failure
An indication returned to the transmitting terminal that the receiving terminal has detected an incoming section failure.
FE SEL - Far End Select
An LED on the faceplate of the SYSCTL circuit pack.
Fibre-Channel - 1G (FC-1G)
A Fibre-Channel 1.0625 Gbps data signal.
Fibre-Channel - 2G (FC-2G)
A Fibre-Channel 2.1250 Gbps data signal.
Fibre Connection (FICON)
A 1.0625 Gbps data signal.
File Transfer and Access Management (FTAM)
FTAM is the Open System Interconnection (OSI) standard for file transfer, file access, and file management.
.........................................................................................................................................................................................................................................................
G L O S S A R Y
G L - 3 4
365-372-300
Issue 8.0 September 2006
Filtering Databese
The filtering database maintains a dynamic list of paths to which packets should be routed based on the destination adress. The database ewnteries are created, updated and removed by the learning process.
FIT
Failures in 10
9 hours of operation.
Flash EPROM
A technology that combined the non volatility of EPROM with the in-circuit reprogrammability of EEPROM (electrically-eraseable PROM).
Forced
Term used when a circuit pack (either working or protection) has been locked into a service-providing state by user command.
Forced Switch to Protection
The WaveStar CIT command that forces the protection group to be the
″
Active Unit.
″
The clear command is required to remove the Forced Switch state. While in the Forced Switch state the system may not switch the active unit either automatically, by means of the WaveStar CIT
Forced Switch, or Manual Switch command.
Forwarding
The state in which an Ethernet port participates in frame relay.
Free Running
An operating condition of a clock in which its local oscillator is not locked to an internal synchronization reference and is using no storage techniques to sustain its accuracy.
FT-2000
Lucent’s SONET OC-48 Lightwave System.
FTAM-FTP Gateway
In Release 3.0 and later releases, the Metropolis
®
DMX supports an FTAM-FTP gateway function. This is also referred to as file transfer translation device (FTTD). The FTTD translates
FTAM over OSI presentation to FTP over TCP/IP.
Function Unit
Refers to any one of a number of different circuit packs that can reside in the A, B,
C, or D function unit slots on the DMX 2.5G Multiplexer.
...........................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
G L O S S A R Y
G L - 3 5
............................................................................................................................................................................................................................................................
G GNE - Gateway Network Element
A network element that passes information between other network elements and management systems through a data communication network.
............................................................................................................................................................................................................................................................
H Hairpin Routing
A cross-connection between function units (inter-function unit). For example, function unit C to function untis A, B, or D. Also, a cross-connection within the same function unit (intra-function unit). Cross-connections go through Main, but no bandwidth or time slots are taken from the backbone ring. Eliminates need for another shelf.
Hashed FTP
In Release 3.0 and later releases, the hashed FTP (digital signature) capability prevents tampering withn a downloadable software image.
Holdover
An operating condition of a network element in which its local oscillator is not locked to any synchronization reference but is using storage techniques to maintain its accuracy with respect to the last known frequency comparison with a synchronization reference.
HFC - Hybrid Fiber Coaxial
Technology using coaxial and fiber cable to transport data services in addition to television channels.
............................................................................................................................................................................................................................................................
I IC - Internal Clock
Used in synchronization messaging.
ID
See shelf ID and site ID.
Insert
To physically insert a circuit pack into a slot, thus causing a system-initiated restoral of an entity into service and/or creation of an entity and associated attributes.
IR - Intermediate Reach
A term used to describe distances of 15 to 40 km between optical transmitter and receiver without regeneration. See long reach.
IS - In Service
One possible state of a DS1, DS3, or EC-1 port. Other possible states are "auto"
.........................................................................................................................................................................................................................................................
G L O S S A R Y
G L - 3 6
365-372-300
Issue 8.0 September 2006
(automatic) and "nmon" (not monitored).
...........................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
G L O S S A R Y
G L - 3 7
............................................................................................................................................................................................................................................................
J Jitter
Timing jitter is defined as short-term variations of the significant instants of a digital signal from their ideal positions in time.
Jumbo Frame
In Release 3.0 and later releases, Metropolis
®
DMX supports jumbo Ethernet frames. Jumbo frames increased network efficiency by reducing the number of frames to be processed.
............................................................................................................................................................................................................................................................
L LBO - Lightguide Build Out
An attenuating (signal-reducing) element used to keep an optical output signal strength within desired limits.
LED - Light Emitting Diode
Used on a circuit pack faceplate to show failure (red) or service state. It is also used to show the alarm and status condition of the system.
LGX - Lightguide Cross-Connect
A SONET device that contains ports for optical fiber connections to an optical network element
(NE). An LGX is used to make and change connections to an NE without changing the cabling on the NE itself.
Line
A transmission medium, together with the associated equipment, required to provide the means of transporting information between two consecutive network elements. One network element originates the line signal; the other terminates it.
Line Timing
The capability to directly derive clock timing from an incoming OC-N signal while providing theuser the capability to provision whether switching to an alternate OC-
N from a different source (as opposed to entering holdover) will occur if the OC-
N currently used as the timing reference for that NE becomes unsuitable as a reference. For example, intermediate nodes in a linear network are line timed. See
Loop Timing.
Listening
The state in which an Ethernet port is preparing to participate in frame relay. In the listening state, frame relay is disabled. This is an interim state between blocking and learning.
Local
See Near-End.
.........................................................................................................................................................................................................................................................
G L O S S A R Y
G L - 3 8
365-372-300
Issue 8.0 September 2006
Local Area Network (LAN)
A communications network that covers a limited geographic area, is privately owned and user administered, is mostly used for internal transfer of information within a business, is normally contained within a single building or adjacent group of buildings, and transmits data at a very rapid speed.
Locked Cross-Connection
This is a variation of the ring cross-connection that allows the user to lock the path selector to a specified rotation of the ring. Any signal received from the other rotation of the ring is ignored.
LOF - Loss of Frame
A failure to synchronize to an incoming signal.
Long Reach (LR)
A term used to describe distances of 40 km or more between optical transmitter and receiver without regeneration. See Intermediate Reach.
A failure to synchronize to an incoming signal.
Loopback
Type of diagnostic test used to compare an original transmitted signal with the resulting received signal. A loopback is established when the received optical or electrical external transmission signal is sent from a port or tributary input directly back toward the output.
Loop Timing
Loop timing is a special case of line timing. It applies to NEs that have only one
OC-N interface. For example, terminating nodes in a linear network are loop timed.
See Line Timing.
LOP - Loss of Pointer
A failure to extract good data from an STS-1 payload.
LOS - Loss of Signal
The complete absence of an incoming signal.
LR - Long Reach
A term used to describe distances of 40 km or more between optical transmitter and reciever without regeneration. See Intermediate Reach.
............................................................................................................................................................................................................................................................
M M23-Format
A standard framing format used for DS3 signals produced by multiplexing 28 DS1s into a DS3 (sometimes referred to as M13-format, without C-bit parity).
...........................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
G L O S S A R Y
G L - 3 9
Main
The two slots (M-1 and M-2) on the DMX Multiplexer shelf in which the OC-12/
48/192 OLIU circuit packs are installed.
Major
Indicates a service-affecting failure, main or unit controller failure, or power supply failure.
Midspan Meet
The capability to interface between two lightwave terminals of different vendors.
This applies to high-speed optical interfaces.
Minor
Indicates a non-service-affecting failure of equipment or facility.
Miscellaneous Discrete Interface
Allows an operations system to control and monitor equipment collocated within a set of input and output contact closures.
Multiplexer
A device (circuit pack) that combines two or more transmission signals into a combined signal on a shared medium.
Multiplexing
The process of combining multiple signals into a larger signal at the transmitter by a multiplexer. The large signal is then split into the original smaller signals at the receiver by a demultiplexer.
Multipoint Cross-Connections
Multipoint cross-connections provide unprotected SONET connections to Ethernet circuit packs.
They form two individual connections.
............................................................................................................................................................................................................................................................
N NE - Near End
The network element the user is at or working on. Also called local.
NE - Network Element
The basic building block of a telecommunications equipment within a telecommunication network that meets SONET standards. Typical internal attributes of a network element include: onr or more high- and low-speed transmission ports, built-in intelligence, synchronization and timing capability, and access interfaces for use by technicians and/or operation systems. In addition, a network element may also include a time slot interchanger.
.........................................................................................................................................................................................................................................................
G L O S S A R Y
G L - 4 0
365-372-300
Issue 8.0 September 2006
Network Service Access Point (NSAP) Adress
Network Service Access Point Address (used in the OSI network layer 3). An automatically assigned number that uniquely identifies a Network Element for the purposes of routing DCC messages.
Network Time Protocol
Network time protocol is an easy, accurate, and automatic method to get and synchronize date/time.
NMA - Network Monitoring and Analysis
An operations system designed by Telcordia Technologies which is used to monitor network facilities.
NMON - Not Monitored
A provisioning state for equipment that is not monitored or alarmed.
No Request State
This is the routine-operation quiet state in which no external command activities are occurring.
Node
A network element in a ring or, more generally, in any type of network. In a network element supporting interfaces to more than one ring, node refers to an interface that is in a particular ring. Node is also defined as all equipment that is controlled by one system controller. A node is not always directly manageable by a management system.
Non-Preemtible Unprotected Traffic (NUT)
Traffic carried on (working and/or protection) BLSR channels for which protection switching has been provisioned as disabled. As the name implies, NUT is unprotected and not preempted in the event of a BLSR protection switch. NUT carried on non-preemptible unprotected channels affords a higher level of survivability as compared to extra traffic, which is preempted during a protection switch, but a lower level of survivability as compared to working traffic, which is carried on its corresponding protection channel during a protection switch.
Non-Revertive Switching
In non-revertive switching, an active and standby line exist on the network. When a protection switch occurs, the standby line is selected to support traffic, thereby becoming the active line.
The original active line then becomes the standby line. This status remains in effect even when the fault clears. That is, there is no automatic switch back to the original status.
Non-Volatile Memory
Memory that retains its stored data after power has been removed. An example of NVM would be a hard disk. The LNW2 contains 2 NVM compact flash cards.
...........................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
G L O S S A R Y
G L - 4 1
Not Monitored (NMON)
Memory that retains its stored data after power has been removed.
NR
Not Reported
NSAP - Network Services Access Point
An address that identifies a network element. Used for maintenance subnetwork communication using the OSI protocol.
............................................................................................................................................................................................................................................................
O OC, OC-n - Optical Carrier
The optical signal that results from an optical inversion of an STS signal; that is,
OC-1 from STS-1 and OC-n from STS-n.
OC-1
Optical Carrier Level 1 Signal (51.844 Mb/s).
OC-3
Optical Carrier Level 3 Signal (155 Mb/s).
OC-3c (STS-3c)
Optical Carrier Level 3 Concatenated Signal. Low-speed broadband equivalent to three STS-1s linked together with a single path overhead.
OC-12
Optical Carrier Level 12 Signal (622 Mb/s).
OC-12c (STS-12c)
Optical Carrier Level 12 Concatenated Signal. High-speed broadband equivalent to twelve STS-1s linked together with a single path overhead.
OC-48
Optical Carrier Level 48 Signal.
Operations Interface
Any interface that provides information on the system performance or control.
These include the equipment LEDs, SYSCTL faceplate, and office alarms.
Operations Interworking
The capability to access, operate, provision, and administer remote systems through craft interface access from any site in a SONET/SDH network or from a centralized operations system.
.........................................................................................................................................................................................................................................................
G L O S S A R Y
G L - 4 2
365-372-300
Issue 8.0 September 2006
OS - Operations System
A central computer-based system used to provide operations, administration, and maintenance functions.
OSI - Open Systems Interconnection
Referring to the OSI reference model, a logical structure for network operations standardized by the Internation Standards Organization (ISO).
OSGNE - Operations System Gateway Network Element
An OSGNE serves as a single interface to the OS for NEs in the same subnetwork using X.25 interfaces.
............................................................................................................................................................................................................................................................
P Pass Through
Paths that are cross-connected directly across an intermediate node in a ring network.
Path
A logical connection between the point at which a standard frame format for the signal at the given rate is assembled, and the point at which the standard frame format for the signal is disassembled.
Path Protection Group
The part of a cross-connection topology that is provisioned to provide path-level protection switching for all the constituent signals carried by the cross-connection. A path protection group can be identified as an entity by its logical output tributary and its cross-connection rate. A path protection group consists of one or more constituent path selectors.
PCMCIA
Personal Computer Memory Card International Association
Peak Information Rate Policer
The peak information rate policer meters packet traffic leaving the internal packet switch and going toward the SONET network. If the packets exceed the provisioned peak information rate, the packets are dropped. This affects the LNW66, LNW67, and LNW68 Ethernet circuit packs in Release 3.0 and later releases.
Performance Monitoring
Measures the quality of service and identifies degrading or marginally operating systems (before an alarm would be generated).
Pipe Mode
Metropolis
®
DMX supports cross-connections on adaptive rate OC-n ports (pipe mode). The
...........................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
G L O S S A R Y
G L - 4 3
signal rates adapt to the supported set of signal rates. Cross-connections may be provisioned at any cross-connection rate that is supported for the tributaries associated with the OC-n ports. A cross-connections can carry any set of constituent signals; however, the total of the constituent signal rates must not exceed the cross-connection rate.
Plesiochronous Network
A network that contains multiple maintenance subnetworks, each internally synchronous and all operating at the same nominal frequency, but whose timing may be slightly different at any particular instant. For example, in SONET networks, each timing traceable to their own Stratum 1 clock are considered plesiochronous with respect to each other.
PM - Performance Monitoring
Measures the quality of service and identifies degrading or marginally operating systems (before an alarm would be generated).
Port (also called Line)
The physical interface, consisting of both an input and output, where an electrical or optical transmission interface is connected to the system and may be used to carry traffic between network elements. The words
″ port
″ and
″ line
″ may often be used synonymously.
″
Port
″ emphasizes the physical interface, and
″ line
″ emphasizes the interconnection. Either may be used to identify the signal being carried.
Port Protection Group
A user provisioned association of protected optical interface ports. This association is used for line protection. The group of ports represent both a protection switching entity and also a set of lines that carry services to/from another network element. The port protection groups also determine the set of logical tributaries from and to which cross-connections can be provisioned.
Port State Provisioning
A feature that allows a user to suppress alarm reporting and performance monitoring during provisioning by supporting multiple states (automatic, in-service, and not monitored) for low-speed ports.
Port Tag
In Transparent mode, a LAN port is assigned membership to a single VLAN with a unique
VLAN ID and this
″ port tag
″ is added to incoming packets and is used is separate that port’s traffic from any other LAN port. Using this added tag makes the network transparent to any
VLAN tags that the user might have in their packets.
Private Line Mode
The private line mode (also known as no tag or repeater mode) is used to establish simple point-to-point connections between two ports with no Ethernet switching functions applied. No
.........................................................................................................................................................................................................................................................
G L O S S A R Y
G L - 4 4
365-372-300
Issue 8.0 September 2006
additional Ethernet provisioning is required after the cross-connection is established.
Proactive Maintenance
Refers to the process of detecting degrading conditions not severe enough to initiate protection switching or alarming, but indicative of an impending signal fail or signal degrade defect (for example, performance monitoring).
Protection
As defined by the SONET standard, the protection line is the pair of fibers (one transmit and one receive) that carry the SONET APS channel (K1 and K2 bytes in the SONET line overhead). On a DMX 2.5G Multiplexer, a protection line is a pair of fibers that terminate an OLIU circuit pack in the Main-2, A-2, B-2, C-2, or D-2 slots. See Service Line.
Product Family 2000
Lucent’s line of SONET standard network products providing total network solutions.
Provisioning
The modification of certain programmable parameters that define how the node functions with various installed entities. These modifications are initiated locally or remotely by either a CIT or an OS. They may arrive at the node via the IAO LAN, CIT port, or any DCC channel. The provisioned data is maintained in NVM and/or hardware registers.
PSTN - Public Switched Telephone Network
The network that provides public telephone service.
PTM - Pluggable Transmission Modules
Also known as SFPs, PTMs are “pluggable” in the sense that they can be plugged into a circuit pack as they become necessary. This allows customers to grow their network incrementally, only realizing the full cost for optics as the need to provision service on (and thus receive revenue from) them becomes necessary.
............................................................................................................................................................................................................................................................
Q Quality of Service
Quality of Service is a term used to denote traffic management capabilities, for the purpose of guaranteeing certain qualities through the network, such as Committed Information Rate (CIR), delay, or jitter. QoS Services are created and accessed based on the Traffic Management Mode (see
ED-
EPORT
) that is provisioned at the port, the port aid, the value of Tag ID and the value of COS. Together these will uniquely address a particular service within the network element.
...........................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
G L O S S A R Y
G L - 4 5
............................................................................................................................................................................................................................................................
R Reactive Maintenance
Refers to decting defects/failures and clearing them.
Remote
See Far-End (FE).
Remote Failure Indication
An indication returned to a transmitting terminal that the receiving terminal has detected an incoming section failure. [Previously called far-end-receive failure (FERF).]
Remote Network Element
Any Network Element that is connected to the referenced Network Element through either an electrical or optical link. It may be the adjacent node on a ring, or N nodes away from the reference. It also may be at the same physical location but is usually at another (remote) site..
Revertive
A protection switching mode in which, after a protection switch occurs, the equipment returns to the nominal configuration (that is, the service equipment is active, and the protection equipment is standby) after the clearing of any failure conditions that caused a protection switch to occur or after any external switch commands are reset. See Non-Revertive.
Ring
A configuration of nodes comprised of network elements connected in a circular fashion. Under normal conditions, each node is interconnected with its neighbor and includes capacity for transmission in either direction between adjacent nodes.
Path switched rings use a head-end bridge and tail-end switch. Line switched rings actively reroute traffic over a protection line.
Ring (0x1) Low-speed Interface
Formerly referred to as dual 0x1 or single 0x1. In ring applications, the DMX 2.5G Multiplexer may use a 0x1 interface, meaning both fibers carry service, as opposed to a linear (1+1) low-speed interface where one fiber is used for service and other for protection. See 1+1.
Ring Circuit Audit
Ring circuit audits validate cross-connection/squelch map information that is manually entered by a user when cross-connections are provisioned and end-to-end circuit connectivity in a
BLSR.
RPP - Reliability Prediction Procedure
Described in Telcordia Technologies TR-NWT-00032.
.........................................................................................................................................................................................................................................................
G L O S S A R Y
G L - 4 6
365-372-300
Issue 8.0 September 2006
RT - Remote Terminal
An unstaffed equipment enclosure that may have a controlled or uncontrolled environment.
............................................................................................................................................................................................................................................................
S Self-Healing
Ring architecture in which two or more fibers are used to provide route diversity.
Node failures only affect traffic dropped at the failed node.
SEO - Single-Ended Operations
The maintenance capability that provides remote access to all DMX 2.5G
Multiplexer systems from a single location over the DCC.
Service Line
On a DMX 2.5G Multiplexer system, a service (or "working") line is a pair of fibers
(one transmit and one receive) that terminate on an OLIU circuit pack in the Main-
1, A-1, B-1, C-1, or D-1 slots. As defined by the SONET standard, the SONET
APS channel is not defined on a service line. See Protection Line.
SES - Severely Errored Seconds
This performance monitoring parameter is a second in which a signal fail occurs, or more than a preset amount of coding violations (dependent on the type of signal) occurs.
SF - Super Frame
The format for DS1 signals.
Shelf ID
A switch-setable parameter with values from 1 to 8. Used to log into a selected shelf in a by using the CIT.
Single 0x1 Cross-Connection
In a dual-homed application, the DMX 2.5G Multiplexer uses a single 0x1 crossconnection to map the VT1.5 channels between the DDM-2000 FiberReach, OC-3
Multiplexer, or OC-12 Multiplexer and the DMX 2.5G Multiplexer rings. This single 0x1 architecture maps low speed to high speed on a specified ring rotation.
The high speed to low speed drop is made on the same specified ring with no path switching. Protection is provided at the VT1.5 end points.
Single Homing
A network topology in which a single DDM-2000 FiberReach, OC-3 Multiplexer, or OC-12 Multiplexer serves as a DMX 2.5G Multiplexer host supporting up to six
OC-3 or OC-12 rings.
...........................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
G L O S S A R Y
G L - 4 7
Slot
A physical position in a shelf for holding a circuit pack and connecting it to the backplane. This term is also used loosely to refer to the collection of ports or tributaries connected to a physical circuit pack placed in a slot.
Software Backup
The process of saving an image of the current network element’s databases, which are contained in its NVM, to a remote location. The remote location could be the WaveStar CIT or an OS.
Software Download
The process of transferring a generic or provisioned database from a remote entity to the target network element’s memory. The remote entity may be the WaveStar CIT or an OS. The download procedure uses bulk transfer to move an uninterpreted binary file into the network element.
Spanning Tree Group
Nodes can be provisioned to belong to a spanning tree group. Only the nodes within that group participate in the spanning tree for the group.
Spanning Tree Protocol
Spanning Tree is a protocol that is run on an Ethernet switch that is connected to one or more
LANs for the purpose of preventing loops in a network. Using the protocol, switches communicate with each other to determine the best
″ tree
″ to span the network by
″ pruning
″
(blocking) links that would cause loops. Spanning Tree is used on packet rings as a protection mechanism by automatically moving the block to a failed link.
Squelch Map
The Squelch Map contains information for each cross-connection in a 2-fiber BLSR and indicates the source and destination nodes for the low-speed circuit that is part of the cross-connection. This information is used to prevent traffic misconnection in rings with isolated nodes or segments.
Standby
Standby identifies a 1+1 protected OC-N line which is not currently selected by the receiver at either end as the payload carrying signal, or 1x1 or 1xN protected circuit pack that is not currently carrying service. See Active.
Status
The indication of a short-term change in the system.
STS, STS-n - Synchronous Transport Signal
The basic building block signal with a rate of 51.840 Mb/s for an STS-1 signal and a rate of n times 51.840 Mb/s for an STS-n signal.
.........................................................................................................................................................................................................................................................
G L O S S A R Y
G L - 4 8
365-372-300
Issue 8.0 September 2006
STS-1 SPE - STS-1 Synchronous Payload Envelope
A 125-microsecond frame structure composed of STS path overhead and the STS-
1 payload.
STS-3c
Synchronous Transport Level 3 Concatenated Signal. See OC-3c.
Subnetwork
A group of interconnected/interrelated Network Elements. The most common connotation is a synchronous network in which the Network Elements have data communications channel (DCC) connectivity.
Superframe Format
A DS1 framing format in which 24 DS0 timeslots plus a coded framing bit are organized into a frame which is repeated 12 times to form the superframe.
Synchronization Messaging
SONET synchronization messaging is used to communicate the quality of network timing, internal timing status, and timing states throughout a subnetwork.
Synchronous Network
The synchronization of transmission systems with synchronous payloads to a master (network) clock that can be traced to a reference clock.
Synchronous Payload
Payloads that can be derived from a network transmission signal by removing integral numbers of bits from every frame. Therefore, no variable bit-stuffing rate adjustments are required to fit the payload in the transmission signal.
Synchronous Payload Envelope
The combined payload and path overhead of an STS-1, STS-3c, STS-12c or STS-
48c signal.
SYSCTL - System Controller
The system controller circuit pack that provides overall administrative control of the terminal.
............................................................................................................................................................................................................................................................
T T1X1 and T1M1
The ANSI committees responsible for telecommunications standards.
Target Identifier (TID)
A provisionable parameter that is used to identify a particular Network Element within a network. It is a character string of up to 20 characters where the characters are letters, digits, or
...........................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
G L O S S A R Y
G L - 4 9
hyphens (-).
TCA - Threshold Crossing Alert
A condition set when a performance monitoring counter exceeds a user-selected threshold. A TCA does not generate an alarm but is available on demand through the CIT and causes a message to be sent to NMA via the X.25/TL1 interface.
Telcordia Technologies
Telcordia Technologies (formerly Bellcore) is a well-recognized telecommunications standards organization.
Test Access
A set of cross-connection topologies used in conjunction with a testing system to monitor and
″ split
″ signal paths for purposes of fault isolation.
TG3 - Stratum 3 Timing Generator
The timing generator circuit pack, located in the Main (high-speed or network interface) OLIU circuit pack, generates clock signals for distribution to the transmit circuits. It operates in the free-running, loop-timing, external timing, and holdover modes.
Through (or Continue) Cross-connection
A cross-connection within a ring, where the input and output tributaries have the same tributary number but are in lines opposite each other.
TL1 - Transaction Language 1
A Telcordia Technologies machine-to-machine communications language that is a subset of ITU-TSS, formerly CCITT’s, human-machine language.
Time Division Multiplexing (TDM)
A technique for transmitting a number of separate data, voice, and/or video signals simultaneously over one communications medium by interleaving a portion of each signal one after another.
Time Slot Assignment (TSA)
A capability that allows any tributary in a ring to be cross-connected to any tributary in any lower-rate, non-ring interface or to the same-numbered tributary in the opposite side of the ring.
Time Slot Interchange (TSI)
The ability of the user to assign cross-connections between any tributaries of any lines within a
Network Element. Three types of TSI can be defined: Hairpin TSI, Inter-ring TSI (between rings), and Intra-ring TSI (within rings).
.........................................................................................................................................................................................................................................................
G L O S S A R Y
G L - 5 0
365-372-300
Issue 8.0 September 2006
Transparent Mode
In Transparent Mode, port tags (which are actually VLAN tags with a TPID value other than
8100hex) are used to separate traffic for different customers. A port tag is added to each incoming frame at the ingress LAN port. The port tag contains a provisionable customer ID and priority level.
Tributary
A path-level unit of bandwidth within a port, or the constituent signal(s) being carried in this unit of bandwidth, for example, an STS-1 tributary within an OC-N port.
............................................................................................................................................................................................................................................................
U UAS - Unavailable Seconds
In performance monitoring, the count of seconds in which a signal is declared failed or, in which, 10 consecutively severely errored seconds (SES) occurred, until the time when 10 consecutive non-SES occur.
Unidirectional Path Switched Ring (UPSR)
Path-Switched rings employ redundant fiber optic transmission facilities in a pair configuration, with one fiber transmitting in one direction (for example, East) and the backup fiber transmitting in the other direction (for example, West). If the active path fails, then the standby path becomes active.
UOC - Univeral Optical Connector
Receptacles on the faceplate of some OLIUs that accept ST, SC, or FC connectors.
UPD/INIT
A push-button on the SYSCTL faceplate.
User Privilege
Permits a user to perform a predefined level of tasks on the computer system on which the system software runs.
............................................................................................................................................................................................................................................................
V Violation Monitor (VM)
A mode of the DS3 circuit pack in which it will monitor but not remove P-bit parity violations on the DS3 signal from the received fiber.
Virtual LAN (VLAN)
A virtual LAN (VLAN) is a subset of a LAN. A VLAN is created by putting VLAN IDs in packets that indicate membership to a VLAN of that ID. A Local Area Network (LAN) can have multiple VLANs within it, up to the number of IDs available. Members (ports) of different
VLANs do not see the traffic of VLANs of which they are not members. A port may be a member of many VLANs (LAN ports in 802.1Q mode, WAN ports). A port may be a member of
...........................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
G L O S S A R Y
G L - 5 1
many VLANs. In the Transparent mode, a LAN port is typically assigned membership to a single VLAN.
In Transparent mode, VLANs are assigned to ports using Port Tag (ed-eport and ed-vcg. In
802.1Q mode, VLANs are assigned to ports using VLAN IDs (ent-vlan/ed-vlan).
A VLAN tag is the specific field of information in a packet that carries the VLAN
ID number.
Virtual Switch
A virtual switch is a grouping of ports on an Ethernet switch that results in partitioning of the switch into multiple
″ logical
″ switches. A port may only be a member of one virtual switch.
Virtual Tributary (VT)
A structure designed for transport and switching of sub-STS-1 payloads. There are currently four sizes: VT1.5 (1.728 Mb/s), VT2 (2.304 Mb/s), VT3 (3.456 Mb/s), and VT6
(6.912 Mb/s).
VMR - Violation Monitor and Removal
A mode of the DS3 circuit pack in which it will monitor and remove P-bit parity violations on the DS3 signal received from the fiber.
VT1.5
A 1.728 Mb/s virtual tributary.
VT1.5 Tributary
A SONET logical signal with a data rate of 1.728 Mbps. In the 9-row structure of the STS-1
SPE, a VT1.5 occupies three columns. VT-structured STS-1 SPEs are divided into seven VT groups. Each VT group occupies twelve columns of the 9-row structure and, for VT1.5s, contains four VTs per group.
VT-G - Virtual Tributary Group
A 9-row by 12-column SONET structure (108 bytes) that carries one or more VTs of the same size. Seven VT groups (756 bytes) are byte-interleaved within the VTorganized STS-1 synchronous payload envelope
............................................................................................................................................................................................................................................................
W Wait-to-Rename
Wait to Rename timer for Optimized 1+1 optical line protection. After a protection switch clears, the system waits the provisioned length of time before renaming the working section 1 and working section 2 as Primary and Secondary.
Wait-to-Restore (WTR)
Applies to revertive switching operation. The protection group enters the WTR state when all
.........................................................................................................................................................................................................................................................
G L O S S A R Y
G L - 5 2
365-372-300
Issue 8.0 September 2006
failure conditions are cleared, but the system has not yet reverted back to its working line. The protection group remains in the WTR state until the Wait-to-Restore timer completes the WTR time interval.
Wavelength Division Multiplexing (WDM)
A means of increasing the information-carrying capacity of an optical fiber by simultaneously transmitting signals at different wavelengths.
WaveStar Product Family
A Lucent line of network products.
WideArea Network (WAN)
A communication network that uses common-carrier provided lines and covers an extended geographical area.
Wizard
A form of user assistance that automates a task through a dialog with the user.
............................................................................................................................................................................................................................................................
X X.25
An ITU standard defining the connection between a terminal and a public packet-switched network
X.25 Interface Protocol
The ITU packet-switched interface standard for terminal access that specifies three protocol layers: physical, link, and packet for connection to a packet-switched data network.
............................................................................................................................................................................................................................................................
Z Zero Code Suppression
A technique used to reduce the number of consecutive zeros in a line-codes signal
(B3ZS for DS3 signals and B8ZS for DS1 signals).
...........................................................................................................................................................................................................................................................
365-372-300
Issue 8.0 September 2006
G L O S S A R Y
G L - 5 3
.........................................................................................................................................................................................................................................................
G L O S S A R Y
G L - 5 4
365-372-300
Issue 8.0 September 2006
Index
.............................................................................
0x1 application mode
,
,
0x1Sn
,
1+1 bidirectional
,
10/100 PL pack description
,
,
10/100BASE-TX
,
10/100T circuit pack description
,
technical specifications
,
1000BASE-LX
1000BASE-SX
,
,
1000BASE-X
100BASE-LX
,
optical specification
,
100BASE-TX
,
12DS3/EC1 circuit pack description
,
performance monitoring
,
technical specifications
,
1G LX circuit pack description
technical specifications
,
1G SX circuit pack description
1Mbps rate limiting
,
20 Amp shelf power
,
28DS1 circuit pack description
technical specifications
,
timing functions
28DS1PM circuit pack description
performance monitoring
,
technical specifications
,
4000 VLANs
,
56DS1PM
,
.............................................................................
A
access network timing
access transport application
,
add/drop cross-connection
,
adjusted F&M Bit
,
administration
,
software upgrades
alarm gateway network element (AGNE)
,
alarms
,
alarm indication signals
(AIS)
,
critical
,
DS1 thresholding
dual OC-12 thresholding
,
groups
major
,
minor
,
OC-48 thresholding
,
...........................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
I N D E X
I N - 1
office
,
quad OC-3 thresholding
,
reports
,
application modes
0x1
,
distinct
,
identical
,
Applications
,
best effort services
Convergence
,
DMX as Hub
,
ethernet private line
ethernet rate shaping
,
Ethernet/TDM access to
IP network
,
Ethernet/TDM access top frame relay and ATM
,
Hitless Bandwidth
Provisioning, LCAS
,
link aggregation
multi-point ethernet private line
,
portless TransMUX
,
SAN Distance Extension
,
TransMUX
,
LNW20
,
transparent LAN
,
virtual LAN
,
applications access transport for voice and private line services
DSLAM access
,
established network evolution
,
features of
interoffice transport
,
with path switched rings
,
Area Address
arrangements bay frames
,
cabinet
,
ASAPs
,
Atomic cross-connections
,
Atomic cross-connects
,
automatic provisioning
,
automatic synchronization reconfiguration
,
access network
autoprovisioning
,
.............................................................................
B
bay arrangements
,
frames
,
bay arrangement typical
,
bidirectional cross-connections
,
bidirectional line-switched ring
,
BLSR
,
bridge and roll
bridged cross-connections
,
build-outs
burst-errored seconds
,
.............................................................................
C
cabinet arrangements
,
outside plant
,
cable management bracket
,
cabling
lightguide build-outs
,
required number
,
Capabilities
,
capacity
C-Bit
,
channel states
,
circuit breakers
,
circuit packs
,
10/100T description
,
12DS3/EC1 description
,
1G LX description
1G SX description
28DS1 description
,
28DS1PM description
,
48DS3/EC1
,
56DS1
,
56DS1PM
8-port GbE
automatic provisioning
,
available
,
descriptions
detectable blank LNW97
,
dual OC-12 description
,
electric continuity test
,
LEDs
,
LNW18
,
...........................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
I N D E X
I N - 2
LNW27
,
LNW28
,
LNW29
,
LNW31
,
LNW32
,
LNW36
,
LNW45
,
LNW46
,
LNW48
,
LNW49
,
LNW50
,
LNW523/527/554
LNW54
,
LNW555
,
LNW56
,
LNW57
,
LNW58
,
LNW59
,
optical spec
,
LNW60
,
LNW62
,
optical spec
,
LNW63
,
LNW64
LNW66
LNW67
LNW68
LNW74
,
LNW66
,
LNW67
,
LNW68
LNW70
LNW70
,
LNW71
,
LNW71
,
LNW73
,
LNW73C
,
LNW74
,
LNW76
LNW77
LNW78
LNW80
LNY76 and LNW77
,
OC-12 (high-speed)
,
OC-192 description
,
OC-48
,
OC-48 (low-speed)
OC-48 description
OC-48 DWDM
,
quad OC-3 description
,
sparing graphs
specifications
,
state reports
SYSCTL
,
description
Trans/MUX
TransMUX circuitpacks
,
OC-192
,
Circuitpacks, Release 5.1.1
,
CIT LAN
,
specifications
,
coding violations
,
Configuraqtions
configurations shelf
,
subnetwork
UPSR control
,
,
embedded operations channel
,
conventions used
course registration
,
CR (Critical) LED
craft interface terminal
,
Cross-connections
0x1
cross-connections
,
add/drop
,
add/drop (1+1)
,
add/drop (BLSR)
,
add/drop (UPSR)
,
allowable
bidirectional
,
bidirectional (two-way)
,
bridge and roll
bridged
,
DRI
dual 0x1
,
ethernet
hairpin
hairpinning
,
hairpinning (Ethernet)
,
locked DS1/DS3
,
locked VT
,
making
,
manual rates
,
mltpt (multi-point)
multi-point (Ethernet)
,
multipoint (Ethernet)
,
...........................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
I N D E X
I N - 3
pass-through
,
pipe-mode
,
provisioning
,
single 0x1
,
types of
unidirectional
,
VT bandwidth
Cross-connects
Atomic
cross-connects atomic
current drain
customized login proprietary messages
.............................................................................
DCC enable/disable
,
Definition
,
digital subscriber line access multiplexer (DSLAM)
,
dimensions
,
Directory services
Distance Extensions
,
distinct application mode
,
DMX cabling
,
circuit packs
cross-connections
,
high capacity shelf
,
introduction to
,
physical arrangements
,
product description
,
,
synchronization
,
system planning and engineering
,
DMXplore
DMXtend
,
document
CD-ROM
,
conventions used
,
how to comment
,
intended audience
,
reason for reissue
documentation ordering
,
DRI
,
drop and continue
,
DS1 locked
DS1 timing output
DS3 sync messaging
locked
,
performance monitoring
(PM)
,
DSLAM access application
,
dual 0x1 cross-connection
,
dual homing
,
dual OC-12 circuit pack description
,
technical specifications
,
Dual Ring Interworking
,
dual ring interworking
,
DWDM
,
LNW221-259,
LNW121-159B
,
DWDM amplifiers
,
D
Data communications channel
Compatibility
,
Provisioning the DCC
,
User side and network side
,
data communications channel specifications
,
Data communications channel (DCC)
data communications channel (DCC)
data storage
,
day bin
,
provisioning
,
DCC
,
see Data communications channel
DCC Compatibility
,
DCC compatibility
.............................................................................
E
E1 support of
,
earthquake requirements
,
electric continuity test tool
,
electrical interfaces
,
10/100T
,
12DS3/EC1
,
28DS1
,
28DS1PM
Electrical PTM
,
...........................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
I N D E X
I N - 4
electrical SFPs
,
,
electronic documentation
,
embedded operations channel
,
EMC requirements
engineering info
VLF rules
,
engineering information
,
,
engineering services
,
environmental considerations
,
earthquake requirements
,
EMC requirements
,
fire resistance
,
humidity
specifications
,
temperature
,
equipment indicators
,
LEDs
lightguide build-outs
,
ordering
,
equipment protection
,
ESCON
,
optical spec
,
optical specification
,
pack description
,
established network evolution
Ethernet cross-connections
,
cross-connections
(hairpinning)
,
cross-connections
(multipoint)
enhancements R4.0
,
enhancements R5.0 &
5.1
,
flow control
,
interworking w/
DDM-2000
,
link aggregation
,
LNW70
LNW74
loopbacks
multicast packets
,
optical Fast E
,
optical specifications
,
pack capacities
pack capacities for rings
,
physical interface
PIR, rate shaping
,
protection link aggregation
,
QoS
LNW70
,
LNW71/74
QoS on EoS VCGs
,
Quality of Service
,
SFP optics
,
specifications
,
switched
,
tagging modes
802.1Q VLAN mode
,
pricate line mode
, switched mode
transparent mode
,
ethernet
,
.............................................................................
F
Failure Rates
Fan Filter
Fast Ethernet private line
SFP optics
fault
...........................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
I N D E X
I N - 5 multipoint applications
,
point-to-point applications
,
Ethernet Circuit Packs
,
ethernet interfaces
10/100T
,
1G LX
,
1G SX
performance monitoring
,
protection
,
ethernet over SONET
ethernet protection ethernet aggregation
,
Ethernet specifications
LNW63
,
LNW73C
,
LNW78
,
LNW78, RPR
,
ethernet specifications
LNW63
,
external equipment specifications
,
external timing mode
,
specification
detection
,
isolation
,
reporting
,
FC
FC-DATA
Features
1+1
,
BLSR interworking
,
bridge and roll
,
cross-connection types
,
DRI
DWDM
,
E1 support
,
electrical packs
Etherenet interworking
,
Ethernet enhancements
R4.0
,
Ethernet enhancements
R5.0 & 5.1
Ethernet/SAN interface circuit packs
,
external optical amplifiers, SFP optics
,
Fast Enternet private line
,
FTP/FTAM
,
GbE packet rings,
VLANs
GbE private line
hardware
High-capacity shelf
,
high-speed 1+1
in-service upgrades
locked DS1/DS3
,
loopbacks
,
ethernet
,
low-speed UPSR
main switch pack, network interface circuit packs
multicast Ethernet
,
networking capabilities
,
NTP
,
NUT
operations
,
other hardware features
,
past releases
,
performance monitoring
,
pipe-mode
proxy ARP
,
rate limiting
,
Release 5.1.1 Release
Plan
,
SAN
,
SNMP
,
software download
,
spanning tree
,
SS bits
,
synchronization
,
test access
,
topologies
,
tributary interface circuit pacs
,
UPSR, BLSR, 1+1
,
VT1.5 granularity
,
features
,
Fibre-Channel
,
pack description
Fibre-channel optical spec
,
FICON
,
optical spec
,
pack description
,
fire resistance
,
FIT rates
equipment
forced switch
,
free running mode
,
specification
FTP over IP
,
FTP/FTAM
FTP/IP
,
,
function units
.............................................................................
G
GbE private line
private lines packet rings
,
GbE Private Line
,
GbE private line
,
Graphic User Interface
,
growth slots
GUI
,
.............................................................................
H
Hairpin
,
hairpin cross-connections
,
Hairpinning
,
hairpinning
,
hardware cabling
,
circuit packs
,
control
shelf description
,
headless main
High Capacity Shelf
,
high-capacity shelf
,
...........................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
I N D E X
I N - 6
history log
,
holdover mode
specification
,
hubbing
,
hybrid optical ethernet interface
,
.............................................................................
I
IAO LAN
,
specifications
,
IAO LAN compatibility
,
IAO LAN ports
,
ID packets
,
identical application mode
,
inactivity timeout period
,
inhibit switch
,
installation services
,
intendend audience
interfaces electrical
,
internal testing
,
interoffice timing
interoffice transport
interworking
,
introduction
,
IP Access
,
IP tunneling
,
IS
Assignment
,
IS-IS level 2 routing
,
ISO standards
.............................................................................
J
jitter
,
jumpers
.............................................................................
L
Lambda UNITE
,
LAN port density
,
LCAS
,
lightguide build-outs
,
technical specifications
,
lightguide jumpers technical specifications
,
line build-outs
DS1
line parameter
,
line state reports
,
line states
,
line switching
,
automatic
,
line timing
,
Line timing from tributary packs
,
line timing mode specification
,
linear optical extensions
,
OC-48
,
Linear UPSR
,
linear UPSR
,
Link Aggregation
,
link aggregation
,
link budgets
,
1G LX
,
,
,
1G SX
,
LNW112 specifications
,
LNW121B-159B optical specifications
,
LNW2
,
LNW20
,
LNW221-259 optical specifications
,
LNW26B optical specifications
,
specifications
LNW27
,
optical specifications
,
specifications
LNW28
,
optical specifications
,
specifications
LNW29
,
optical specificationsLNW32 optical specifications
,
specifications
LNW31
,
specifications
LNW32
,
specifications
LNW36
,
allowed optics
,
optical specifications
,
specifications
LNW37 optical specifications
,
LNW421-459 optical specifications
,
...........................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
I N D E X
I N - 7
LNW45
,
allowed optics
optical specifications
,
specifications
,
LNW46
,
optical specifications
,
specifications
,
LNW48
,
optical specifications
,
specifications
,
LNW49
,
optical specifications
,
specifications
,
LNW50
,
optical specifications
,
specifications
,
LNW523 optical specifications
,
LNW523/527/554
,
LNW527 optical specifications
,
specifications
,
LNW54
,
optical specifications
,
specifications
,
LNW554 optical specifications
,
specifications
,
LNW555
,
optical specifications
,
specifications
,
LNW56
optical specifications
,
specifications
,
LNW57
optical specifications
,
specifications
,
LNW58
optical specifications
,
specifications
,
LNW59
optical spec
,
LNW6 specifications
,
LNW60
optical specifications
,
specifications
,
LNW62
optical spec
,
LNW63
LNW64
LNW66
PIR
,
LNW67
PIR
,
specification
,
LNW68
PIR
,
specification
,
LNW7 specifications
,
LNW70
QoS
SFP optics
SFPs
,
specification
LNW71 pack description
,
LNW73
applications
SFP optics
specification
LNW73C
,
LNW74 pack description
,
SFP optics
LNW76
,
optical specifications
,
specifications
LNW77
,
optical specifications
,
specifications
LNW78
,
hubbing
,
LNW8 specifications
LNW80
,
LNW93
,
LNW94
,
LNW97
,
locked DS1/DS3
Locked VT cross-connections
login
,
loopbacks
,
DS1
,
...........................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
I N D E X
I N - 8
.............................................................................
M
MAC address locking
,
Main slots
,
main switch pack
,
maintenance
,
fault detection
,
fault isolation
fault reporting
,
history reports
loopbacks and tests
,
proactive
remote
,
signaling
,
three-tiered operations
,
manual cross-connection rates
,
manual switch
medium fabric
,
medium fabric cards
,
Miscellaneous Discrete
Interfaces
,
miscellaneous equipment and tools
,
mixed protection modes
,
MJ (Major) LED
mltpt (multi-point) cross-connections
,
MN (Minor) LED
modems
,
MTBF
,
Multiple Area Addressing
,
multipoint ethernet applications
,
multi-service interfaces
,
multivendor
,
N
multi-vendor operations interworking
NVM
,
OC-192
VLF
,
,
,
.............................................................................
network bay frames
,
configurations
flexibility
,
synchronization
,
synchronization environment
,
timing distribution
timing distribution questions
,
topologies
,
Network element (NE) login administration and security
Security
,
network partitioning
Network size
network time protocol
NMA
,
Non-preemtible Unprotected
Traffic
Non-volatile Memory card
,
NSAP
,
NSAP AREA
,
NSAP provisioning
.............................................................................
O
OADMs
,
OC-12 (high-speed)
,
,
OC-12 high-speed
,
Main slots
,
OC-192 UPSR
,
configurations
,
specifications
OC-192/OC-48 unidirectional path switched ring
,
OC-48
4-port LNW62
,
LNW26B
,
UPSR
OC-48 circuit pack description
,
,
Main slots
,
technical specifications
,
OC-48 DWDM
OC-48 UPSR
,
configurations
,
specifications
OC-N performance parameters
,
OLIUs specifications
,
operations
,
alarm groups interworking
,
,
multi-vendor interworking
three-tiered
,
three-tiered operations interface
,
tier 1
,
OC-192 circuit pack description
...........................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
I N D E X
I N - 9
tier 2 tier 3
,
,
optical line interfaces purpose of
,
topology
,
typical applications
,
Operations Interfaces
Miscellaneous Discrete
Interface
,
Office Alarms Interface
,
PC-CIT
,
operations interfaces
,
craft interface terminal
,
LEDs
PC/CIT
,
Operations Interworking
operations interworking
,
, optical linear extensions
,
parameters
,
OC-192
,
optical loopbacks ordering
accessories
,
,
documentation software
how to order
,
lightguide build-outs and tools
,
shelf assembly
,
software
,
miscellaneous equipment
OS
OSI
,
specifications
,
OSI on the IAO LAN
path switching application modes path witching
P-Bit
PC/CIT
PC-CIT
,
Features and Uses
,
performance status reports
system
,
performance monitoring
,
data storage
,
DS1
DS3
,
,
OSI or TCP/IP on the same
IAO LAN
,
outside plant cabinet
ethernet interfaces
,
ethernet specifications
,
line parameter
,
parameter thresholds
,
optical Ethernet
,
optical interfaces
1G LX
,
.............................................................................
P
packet rings
parameters and traps
passive optics passive optics box
,
parameters
,
path parameter
,
1G SX
dual OC-12
,
LNW31
,
OC-192
topology example pass-through
,
cross-connection
,
reports
,
SONET parameters specifications
,
performance monitoring
(PM)
OC-3
OC-48
quad OC-3
SONET specifications
,
password
,
password aging path parameter operation
,
,
path state reports
,
path switched rings
,
definition trouble performance parameters
,
OC-N
,
...........................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
I N D E X
I N - 1 0
STS
personal computer specifications
,
physical arrangements
,
physical specification
,
physical specifications
,
power
,
pipe-mode
,
PM
monitoring point-to-point ethernet applications
,
port state reports
,
port states
,
port units passive optics
,
portless TransMUX
,
POUs
,
power requirements
,
PRBS generation/detection
,
private line services
,
private lines
,
proactive maintenance
product description
,
Product Family 2000 interworking with
,
protection switch, in a BLSR
,
,
protection switching
,
equipment
ethernet interfaces
,
line
,
mixed modes
,
path
,
priorities
,
technical specifications
,
provisioning
auto provisioning
,
automatic
,
channel states
circuit pack replacement
,
cross-connections
,
default
line states
parameter thresholds
,
port states
remote
reports
Provisioning the DCC
proxy ARP
,
PTMs
,
.............................................................................
Q
QoS
QoS on EoS VCGs
,
quad OC-3 circuit pack description
technical specifications
,
quarter-hour bin
,
provisioning
.............................................................................
R
R7.0
,
R7.0, Release 7.0, Features
,
reason for reissue
,
reliability warranty
,
remote maintenance
,
provisioning
,
Remote NE-NE Software
Copy
reports
,
alarm and status
circuit pack states
,
line states
,
maintenance history
,
path states
,
performance monitoring
,
port states
,
provisioning
,
threshold crossing alerts
,
version/equipment list
,
rings homing to
path switched
RPR
,
application, Bridging, fairness
,
MIBs
,
.............................................................................
S
S1 byte
,
safety labels
,
SAN
,
,
Compression
,
optical specification
,
packs description
,
SFP optics
specification
...........................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
I N D E X
I N - 1 1
SAN compression
,
SAN pack detail
Section DCC
,
Security
,
Capabilities
,
System initialization
,
User types
,
security
,
default login and password
,
self healing
service applications
,
services worldwide
,
seven layer protocol stack
,
seven-layer protocol stack
,
SFP optics
,
SFPs
,
electrical SFPs
,
,
shelf assembly
backplane
,
cabling
,
capacity
circuit packs
,
configurations
,
Control slot
,
description
,
front view
Main slots
physical characterisics
,
power
,
size
,
,
signal performance
,
single 0x1 cross-connection
single homing
slot equippage
,
SNMP
,
Software Download
,
software download
,
,
personal computer specifications
SONET
,
data communications channel
overhead bytes
,
performance monitoring parameters
,
spanning tree
,
fast
sparing
,
circuit packs
graphs
specifications environmental
physical
,
SONET optical interfaces
technical
,
stacked VLANs
,
standards transmission interfaces
,
state reports
status reports
,
performance
Stratum 3 Timing Generator
,
stratum 3 timing generator
,
embedded in OC-48/192
,
.........................................................................................................................................................................................................................................................
I N D E X
I N - 1 2
365-372-300
Issue 8.0, September 2006
,
OLIUs
,
STS performance parameters
,
subnetwork configurations
,
external timing
,
external timing/line timing
,
free running/line timing
,
Subnetwork Partitioning
Advantages
Guidelines
suitcasing, training courses
,
super user
WaveStar CIT
switch fabric engineering rules
switched Ethernet
,
switching
1+1 bidirectional
,
sync messaging
,
automatic synchronization reconfiguration
DS1 timing output integrity
,
synchronization provisioning integrity
,
synchjronization tributary line timing
,
Synchronization
Line timing from tributary packs
,
synchronization
,
DS1 timing output
dual reference monitoring
external timing
,
external timing/line timing
,
features
,
free running
,
free running/line timing
,
functions
holdover mode
line timing
,
network synchronization environment
provisioning integrity
,
recommendations
,
SDH sync
,
Stratum 3 Timing
Generator
,
sync messaging
,
technical specifications
,
timing distribution
,
timing modes
,
synchronization messaging
,
SYSCTL circuit pack control
Control slot
,
description
,
faceplate
operations tier 1
,
system planning
,
System Controller circuit pack
System initialization
,
system overview
,
system performance
jitter
,
peformance monitoring
,
protection switching
,
signal performance
,
SONET overhead bytes
,
synchronization
,
transient performance
,
transmission delay
,
wander
,
.............................................................................
T
TARP
Parameters
Provisioning
,
TARP data cache
,
Accuracy
,
TARP NSAP-to-TID translations
,
TARP propagation
,
TARP provisioning
,
TARP TID-to-NSAP translations
,
TCP/IP
,
performance monitoring
,
specifications
,
TCP/IP on the IAO LAN
technical specifications
10/100T
,
,
,
,
...........................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
I N D E X
I N - 1 3
12DS3/EC1
,
1G LX
,
1G SX
,
28DS1
,
28DS1PM
dual OC-12
electrical interfaces
,
ethernet
external equipment
,
OC-48
operations interfaces
,
optical interfaces
,
optical link budgets
,
optical receiver
,
,
optical system
,
optical transmitter
,
performance monitoring
,
physical
power
protection switching
,
quad OC-3
,
signal performance
,
SONET overhead bytes
,
synchronization
,
system performance
,
transient performance
,
transmission delay
,
technical specifications
48DS3EC1
,
technical specifications
56DS1
technical specifications
OC-12 (high-speed)
,
technical specifications
OC-48 (low-speed)
,
technical specifications
OC-48 DWDM
technical specifications
TransMUX
TEMS
,
Test Access detail
test access
,
testing internal
,
specific
,
three-tiered operations interface
,
threshold crossing alerts
,
reports
,
transmission to OS
thresholds
,
TID
,
TID provisioning
,
Time and Date
Synchronization
,
timing access network
,
alternate sources
,
distribution
distribution questions
,
DS1 timing functions timing modes
TIRKS
TL1
free running
,
holdover mode
,
external
,
specifications
,
tributary line timing
,
TCP/IP
,
translation device
,
Tl1 Translation
,
increased span length amplifiers
packet rings
,
DS1 timing output
,
interoffice distribution
,
external timing/line timing
free running
,
free running/line timing
,
command builder
,
management
,
messaging
,
over TCP/IP
,
TL1 Translation Device
(T-TD)
,
,
TL1/X.25
,
tools
,
Topologies
,
0x1
,
DWDM
hairpinning
,
topologies
,
dual homing
hubbing
,
linear optical extensions
,
path switched rings single homing
transient performance
,
transmission
.............................................................................
U
unidirectional cross-connections
unprotected paths
,
,
Unprotected UPSR
,
unprotected UPSR
,
Update/Initialize
UPSR
configurations
,
specifications
User side and network side
,
User types
.............................................................................
V
V4 byte
,
,
Trans/MUX circuit pack
,
delay
,
interface standards
threshold crossing alerts
,
TransMUX
,
LNW20
,
portless
True 0x1
,
two-way cross-connections
,
.........................................................................................................................................................................................................................................................
I N D E X
I N - 1 4
365-372-300
Issue 8.0, September 2006
,
VCAT
VCG
,
port density
,
virtual concatenation
virtual LAN (VLAN)
VLAN
,
VLANs
,
VLF Main
engineering rules
,
VLF Main, LNW59
voice services
VT bandwidth assignment of
,
VT fabric capacity
VT Ring closure
,
VT Ring-closure
VT1.5 granularity
.............................................................................
W
wander
warranty
,
WaveStar Product Family interworking with
,
worldwide services
...........................................................................................................................................................................................................................................................
365-372-300
Issue 8.0, September 2006
I N D E X
I N - 1 5
Atsisiųsti