Cisco Enterprise Performance Datasheet
Διαφήμιση
Διαφήμιση
Cisco UCS C220 M3
High-Density Rack Server
(Small Form Factor Disk
Drive Model)
C ISCO S YSTEMS
170 W EST T ASMAN D R
S AN J OSE , CA, 95134
WWW .
CISCO .
COM
P UBLICATION H ISTORY
R EV B.13
A PRIL 24, 2013
BASE SERVER STANDARD CAPABILITIES and FEATURES . . . . . . . . . . . . . . . . . 6
CONFIGURING the SERVER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
STEP 5 SELECT HARD DISK DRIVES (HDDs) or SOLID STATE DRIVES (SSDs) . . . . . . . . . . . . . 24
STEP 7 ORDER OPTIONAL NETWORK CARD ACCESSORIES . . . . . . . . . . . . . . . . . . . . . . . . 28
STEP 10 ORDER OPTIONAL REVERSIBLE CABLE MANAGEMENT ARM . . . . . . . . . . . . . . . . . 35
STEP 11 ORDER A TRUSTED PLATFORM MODULE (OPTIONAL) . . . . . . . . . . . . . . . . . . . . . 36
STEP 12 ORDER CISCO FLEXIBLE FLASH SD CARD MODULE (OPTIONAL) . . . . . . . . . . . . . . . 37
STEP 16 SELECT OPTIONAL VALUE-ADDED SOFTWARE . . . . . . . . . . . . . . . . . . . . . . . . . 42
OPTIONAL STEP - ORDER RACK(s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
OPTIONAL STEP - ORDER PDU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
SUPPLEMENTAL MATERIAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
CPU Removal and Installation (“pick n place”) Tool Set . . . . . . . . . . . . . . . . . . . . . 60
Thermal Grease (with syringe applicator) for CPU to Heatsink Seal . . . . . . . . . . . . . . 61
TECHNICAL SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
2 Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
OVERVIEW
OVERVIEW
The Cisco® UCS C220 M3 rack server is designed for performance and density over a wide range of business workloads from web serving to distributed database.
Building on the success of the Cisco UCS C200 M2 rack server, the enterprise-class UCS C220 M3 server further extends the capabilities of Cisco’s Unified Computing System portfolio in a 1U form factor with the addition of the Intel® E5-2600 series product family CPUs that deliver significant performance and efficiency gains. In addition, the UCS C220 M3 server provides 16 DIMM slots, up to 8 drives and 2 x 1 GbE
LAN-on-motherboard (LOM) ports delivering outstanding levels of density and performance in a compact 1U package.
Figure 1 Cisco UCS C220 M3 High-Density SFF Rack Server
Front View
Rear View
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) 3
DETAILED VIEWS
DETAILED VIEWS
Chassis Front View
Figure 2 shows the Cisco UCS C220 M3 High-Density SFF Rack Server.
Figure 2 Chassis Front View
1 2 3
4
5
6
7 8
HDD4 HDD5
HDD1
HDD6
10
HDD2
HDD7
HDD3
HDD8
9
3
4
1
2
5
Power button/power status LED
Identification button/LED
System status LED
Fan status LED
Temperature status LED
8
9
6
7
10
Power supply status LED
Network link activity LED
Asset tag (serial number)
KVM connector (used with KVM cable that provides two USB, one VGA, and one serial connector)
Drives (up to eight hot-swappable 2-5-inch drives)
For more information about the KVM cable connection, see
.
4 Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
DETAILED VIEWS
Chassis Rear View
Figure 3 shows the external features of the rear panel.
Figure 3 Chassis Rear View
1 2
PCIe2
3
PCIe1
4 5 6 7 8 9
1
2
3
4
5
Power supplies (up to two) 6
Slot 2: Low-profile PCIe slot on riser:
(half-height, half-length, x16 connector, x8 lane width)
Slot 1: Standard-profile PCIe slot on riser:
(full-height, half-length, x24 connector, x16 lane width) (supports Cisco Virtual Interface
Card (VIC)
VGA video connector
Serial port (RJ-45 connector)
7
8
9
—
One 10/100/1000 Ethernet dedicated management port
Dual 1-Gb Ethernet ports
(LAN1 and LAN2)
USB ports
Rear Identification button/LED
—
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) 5
BASE SERVER STANDARD CAPABILITIES and FEATURES
BASE SERVER STANDARD CAPABILITIES and FEATURES
lists the capabilities and features of the base server. Details about how to configure the server for a particular feature or capability (for example, number of processors, disk drives, or amount of memory)
are provided in CONFIGURING the SERVER, page 9 .
Table 1 Capabilities and Features
Capability/Feature
Chassis
CPU
Chipset
Memory
NIC
Expansion slots
Internal storage devices
Cisco Flexible Flash drives
Video
Description
One rack unit (1RU) chassis
One or two Intel® E5-2600 series processor family CPUs
Intel® C600 series chipset
16 slots for registered or unbuffered ECC DIMMs (RDIMMs or UDIMMs) or load-reduced DIMMs (LRDIMMs)
Embedded dual-port Intel i350 PCIe-based Gigabit Ethernet controller, supporting the following:
■
■
Pre-Execution Boot (PXE boot) iSCSI boot
Two PCIe slots (on a riser card)
■ One full-height profile, half-length slot with x24 connector and x16 lane
■ One half-height profile, half-length slot with x16 connector and x8 lane
Drives are installed into front-panel drive bays that provide hot-pluggable access.
■ Small Form Factor (SFF) drives. Up to eight 2.5-inch SAS or SATA hot-swappable hard disk drives (HDDs) or solid state drives (SSDs)
■ The server also contains one internal USB 2.0 port on the motherboard that you can use with a USB thumb drive for additional storage
The server supports one internal Cisco Flexible Flash drive (SD card).
■ The SD card is pre-loaded with four virtual drives. The four virtual drives contain, respectively, the Cisco Server Configuration Utility, the Cisco
Host Upgrade Utility, the Cisco C-Series server drivers set, and a blank virtual drive on which you can install an OS or a hypervisor
■ 4 GB is available for general use
The Emulex Pilot 3 Integrated Baseboard Management Controller provides video:
■
■
■ Matrox G200e video controller
■ Integrated 2D graphics core with hardware acceleration
■ Supports all display resolutions up to 1920 x 1200 x 16 bpp resolution at
60 Hz
24-bit color depth for all resolutions less than 1600x1200
256 MB video memory
6 Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
Capability/Feature
Storage controller
Interfaces
Front Panel
Power subsystem
BASE SERVER STANDARD CAPABILITIES and FEATURES
Description
■
■
■
Embedded RAID (3 Gbs)
• Embedded SATA-only RAID controller, supporting up to 4 SATA-only drives (RAID 0, 1, 10)
• ROM5 embedded RAID upgrade, supporting up to 8 SAS+SATA drives
(RAID 0, 1, 10).
• ROM55 embedded RAID upgrade, supporting up to 8 SAS+SATA drives
(RAID 0, 1, 5, 10).
2008M-8i Mezzanine Cards (6 Gbs) - two versions
• Cisco UCSC RAID SAS 2008M-8i Mezzanine Card, supporting up to 8
SAS+SATA drives supporting RAID 0, 1, 5, 10, and 50. SAS and SATA drives can be mixed. This card has a product ID (PID) of
UCSC-RAID-11-C220.
• Cisco UCSC RAID SAS 2008M-8i Mezzanine Card, supporting up to eight SAS/SATA drives supporting RAID 0, 1, and 10. This card has a product ID (PID) of UCSC-RAID-MZ-220 .
Plug-in PCIe Cards (6 Gbs)
• LSI MegaRAID SAS 9266CV-8i RAID 8-port PCIe plug-in RAID controller card with on-board 1 GB data cache and chassis-mounted (remote) supercap for data cache power backup, supporting RAID levels 0, 1,
5, 6, 10, 50, 60 and up to eight internal SAS+SATA drives.
• LSI MegaRAID 9285CV-8e PCIe plug-in RAID controller card with on-board 1 GB cache and chassis-mounted (remote) supercap for data cache power backup, supporting RAID levels 0, 1, 5, 6, 10, 50,
60. Supports 8 external SAS ports (up to 240 external drives).
■
■
■
Rear panel
• One RJ45 serial port connector
• Two USB 2.0 port connectors
• One DB15 VGA connector
• Two RJ-45 10/100/1000 Ethernet port connectors
• One RJ-45 10/100/1000 Ethernet management port, using Cisco
Integrated Management Controller (CIMC) firmware
Various PCIe card ports (dependent on which cards are installed)
• Converged Network Adapter (CNA) ports
• Network Interface Card (NIC) ports
• Host Bus Adapter (HBA) ports
Front panel
• One KVM console connector (supplies two USB, one VGA, and one serial connector)
A front panel controller provides status indications and control buttons
Up to two 450 W 650 W power supplies. One is mandatory; one more can be added for 1 + 1 redundancy.
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) 7
BASE SERVER STANDARD CAPABILITIES and FEATURES
Capability/Feature
Fans
Integrated management processor
Description
Chassis:
■ Five hot-swappable fans for front-to-rear cooling
Power supply:
■ Each power supply is equipped with a fan.
Cisco Integrated Management Controller (CIMC) firmware.
Depending on your CIMC settings, the CIMC can be accessed through the 1-Gb
Ethernet dedicated management port, the 1-Gb Ethernet LOM ports, or a
Cisco 1225 virtual interface card (VIC).
8 Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
CONFIGURING the SERVER
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
Follow these steps to configure the Cisco UCS C220 M3 High-Density SFF Rack Server:
STEP 1 VERIFY SERVER SKU, page 10
STEP 4 SELECT RAID CONFIGURATION, page 18
STEP 5 SELECT HARD DISK DRIVES (HDDs) or SOLID STATE DRIVES (SSDs), page 24
STEP 6 SELECT PCIe OPTION CARD(s), page 26
STEP 7 ORDER OPTIONAL NETWORK CARD ACCESSORIES, page 28
STEP 8 ORDER POWER SUPPLY, page 31
STEP 9 SELECT AC POWER CORD(s), page 32
STEP 10 ORDER OPTIONAL REVERSIBLE CABLE MANAGEMENT ARM, page 35
STEP 11 ORDER A TRUSTED PLATFORM MODULE (OPTIONAL), page 36
STEP 12 ORDER CISCO FLEXIBLE FLASH SD CARD MODULE (OPTIONAL), page 37
STEP 13 ORDER OPTIONAL USB 2.0 DRIVE, page 38
STEP 14 SELECT OPERATING SYSTEM, page 39
STEP 15 SELECT OPERATING SYSTEM MEDIA KIT, page 41
STEP 16 SELECT OPTIONAL VALUE-ADDED SOFTWARE, page 42
STEP 17 SELECT SERVICE and SUPPORT LEVEL, page 43
OPTIONAL STEP - ORDER RACK(s), page 48
OPTIONAL STEP - ORDER PDU, page 49
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) 9
CONFIGURING the SERVER
STEP 1 VERIFY SERVER SKU
Verify the product ID (PID) of the server as shown in
.
Table 2 PID of the C220 M3 High-Density SFF Rack Base Server
Product ID (PID)
UCSC-C220-M3S UCS C220 M3 SFF, no CPU, memory, HDD, SDD, power supply, SD card, or PCIe cards, with 1 rail kit
Description
■
■
The Cisco C220 M3 server:
Includes one tool-less rail kit
Does not include power supply, CPU, memory, hard disk drives (HDDs), solid-state drives
(SSDs), SD card, or plug-in PCIe cards.
NOTE: Use the steps on the following pages to configure the server with the components that you want to include.
10 Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
STEP 2 SELECT CPU(s)
■
■
■
The standard CPU features are:
Intel E5-2600 series processor family CPUs
Intel C600 series chipset
Cache size of 10, 15, or 20 MB
Select CPUs
The available CPUs are listed in Table 3
.
Table 3 Available Intel CPUs: E5-2600 Series Processor Family CPUs
Product ID (PID)
Intel
Number
Clock
Freq
(GHz)
Power
(W)
Cache
Size
(MB)
Cores QPI
UCS-CPU-E5-2690
UCS-CPU-E5-2680
UCS-CPU-E5-2670
UCS-CPU-E5-2667
UCS-CPU-E5-2665
UCS-CPU-E5-2660
UCS-CPU-E5-2650
UCS-CPU-E5-2650L
UCS-CPU-E5-2643
UCS-CPU-E5-2640
UCS-CPU-E5-2630
UCS-CPU-E5-2630L
UCS-CPU-E5-2620
UCS-CPU-E5-2609
E5-2690
E5-2680
E5-2670
E5-2667
E5-2665
E5-2660
E5-2650
E5-2650L
E5-2643
E5-2640
E5-2630
E5-2630L
E5-2620
E5-2609
2.90
2.70
2.60
2.90
2.40
2.20
2.00
1.80
3.30
2.50
2.30
2.00
2.00
2.40
135
130
115
130
115
95
95
70
130
95
95
60
95
80
20
20
20
15
20
20
20
20
10
15
15
15
15
10
8
8
8
6
8
8
8
8
4
6
6
6
6
4
8 GT/s
8 GT/s
8 GT/s
8 GT/s
8 GT/s
8 GT/s
8 GT/s
8 GT/s
8 GT/s
7.2 GT/s
7.2 GT/s
7.2 GT/s
7.2 GT/s
6.4 GT/s
Notes . . .
1. If higher or lower speed DIMMs are selected than what is shown in the table for a given CPU, the DIMMs will be clocked at the lowest common denominator of CPU clock and DIMM clock.
Highest DDR3
DIMM Clock
Support (MHz) 1
1600
1333
1333
1333
1333
1066
1600
1600
1600
1600
1600
1600
1600
1600
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) 11
CONFIGURING the SERVER
Approved Configurations
(1) 1-CPU configurations:
■ Select any one CPU listed in
(2) 2-CPU Configurations:
■
Select two identical CPUs from any one of the rows of Table 3 on page 11
.
Caveats
■
■
You can select either one processor or two identical processors.
For optimal performance, select DIMMs with the highest clock speed for a given processor
). If you select DIMMs whose speeds are lower or higher than that shown in the tables, suboptimal performance will result.
12 Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
STEP 3 SELECT MEMORY
Figure 4
The standard memory features are:
■
■
DIMMs
— Clock speed: 1333 or 1600 MHz
— Ranks per DIMM: 1, 2, or 4
— Operational voltage: dual voltage capable (1.5 V or 1.35 V)
— Registered or unbuffered ECC DDR3 DIMMs (RDIMMs or UDIMMs) or load-reduced
DIMMs (LRDIMMs)
Memory is organized with four memory channels per CPU, with up to two DIMMs per channel, as shown in
C220 M3 SFF Memory Organization
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) 13
CONFIGURING the SERVER
Select DIMMs and Memory Mirroring
Select the memory configuration and whether or not you want the memory mirroring option.
The available memory DIMMs and mirroring option are listed in
.
NOTE: When memory mirroring is enabled, the memory subsystem simultaneously writes identical data to two channels. If a memory read from one of the channels returns incorrect data due to an uncorrectable memory error, the system automatically retrieves the data from the other channel. A transient or soft error in one channel does not affect the mirrored data, and operation continues unless there is a simultaneous error in exactly the same location on a DIMM and its mirrored
DIMM. Memory mirroring reduces the amount of memory available to the operating system by 50% because only one of the two populated channels provides data.
Table 4 Available DDR3 DIMMs
Product ID (PID) PID Description
DIMM Options
UCS-ML-1X324RY-A 32GB DDR3-1600-MHz LR DIMM/PC3-12800/quad rank/x4/1.35v
UCS-MR-1X162RY-A 16GB DDR3-1600-MHz RDIMM/PC3-12800/dual rank/x4/1.35v
UCS-MR-1X082RY-A 8GB DDR3-1600-MHz RDIMM/PC3-12800/dual rank/x4/1.35v
UCS-MR-1X082RX-A 8GB DDR3-1333-MHz RDIMM/PC3-10600/dual rank/x4/1.35v
UCS-MR-1X041RY-A 4GB DDR3-1600-MHz RDIMM/PC3-12800/single rank/x4/1.35v
UCS-MR-1X041RX-A 4GB DDR3-1333-MHz RDIMM/PC3-10600/single rank/x4/1.35v
UCS-MU-1X042RE-A 4GB DDR3-1600-MHz ECC UDIMM/PC3-12800/dual rank/x8/1.35v
Memory Mirroring Option
N01-MMIRROR Memory mirroring option
Voltage
Ranks/
DIMM
1.35 V
1.35 V
1.35 V
1.35 V
1.35 V
1.35 V
1.35 V
4
2
2
2
1
1
2
14 Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
Approved Configurations
(1) 1-CPU configuration without memory mirroring:
■ Select from 1 to 8 DIMMs. Refer to
Memory Population Rules, page 53
, for more detailed information.
(2) 1-CPU configuration with memory mirroring:
■ Select 2, 4, 6, or 8 identical DIMMs. The DIMMs will be placed by the factory as shown in the following table.
Total
Number of
DIMMs
2
4
6
8
(A1, B1)
(A1,B1); (C1,D1)
(A1,B1); (C1,D1)
(A1,B1); (C1,D1)
CPU 1 DIMM Placement in Channels
(for identical DIMMs)
Blue Slots Black Slots
(A2,B2)
(A2,B2); (C2,D2)
■
Select the memory mirroring option (N01-MMIRROR) as shown in
(3) 2-CPU configuration without memory mirroring:
■
Select from 1 to 8 DIMMs per CPU. Refer to Memory Population Rules, page 53 , for more
detailed information.
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) 15
CONFIGURING the SERVER
(4) 2-CPU configuration with memory mirroring:
■ Select 2, 4, 6, or 8 identical DIMMs per CPU. The DIMMs will be placed by the factory as shown in the following table.
Number of
DIMMs per CPU
2
4
6
8
CPU 1 DIMM Placement in Channels
(for identical dual-rank DIMMs)
Blue Slots Black Slots
(A1, B1)
(A1,B1); (C1,D1)
(A1,B1); (C1,D1)
(A1,B1); (C1,D1)
(A2,B2)
(A2,B2); (C2,D2)
CPU 2 DIMM Placement in Channels
(for identical dual-rank DIMMs)
Blue Slots Black Slots
(E1, F1)
(E1,F1); (G1,H1)
(E1,F1); (G1,H1)
(E1,F1); (G1,H1)
(E2,F2)
(E2,F2); (G2,H2)
■
Select the memory mirroring option (N01-MMIRROR) as shown in Table 4 on page 14 .
NOTE: System performance is optimized when the DIMM type and quantity are equal for both CPUs, and when all channels are filled equally across the CPUs in the server.
16 Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
Caveats
■
■
■
■
■
■
■
■
■
■
For optimum performance, do not mix DIMMs with different frequencies. If you mix DIMM frequencies, the system defaults to the lower frequency.
Do not mix RDIMMs, LRDIMMs, or UDIMMs
DIMMs for CPU 1 and CPU 2 (when populated) must always be configured identically.
The server supports 1 or 2 DIMMs per channel for single- or dual-rank RDIMMs.
The server supports 1 or 2 DIMMs per channel for quad-rank LRDIMMs.
When using mirroring, DIMMs must be installed in identical pairs across paired DDR3 buses.
That is, mirrored pairs in channels A and B must be identical and pairs in channels C and D must be identical. However, the DIMMs used in channels A and B and in C and D can be different.
Non-ECC DIMMs are not supported.
Memory mirroring reduces the amount of available memory by 50% (quantity of DIMMs must be even for mirroring).
When single- and dual-rank DIMMs are populated for 2DPC, always populate the dual rank
DIMM in the blue DIMM slot, and the single-rank DIMM in the black DIMM slot (only the 4GB
DIMMs are single-rank).
By default, all DIMMs run at 1.35 V, which yields 1333-MHz memory speeds. To run the memory DIMMS at 1600 MHz, you need to go into the BIOS or set the policy with UCSM
(service profile) to run in Performance Mode. This forces the DIMMs to operate at 1.5 V and yields 1600-MHz speeds, provided:
— The DIMMs are 1600-MHz devices and the DIMM type is RDIMM
— The CPUs chosen support 1600-MHz operation.
NOTE: 32 GB LRDIMMs run at a maximum speed of 1333 MHz for 1DPC and 2DPC even though their specified maximum speed is 1600 MHz.
NOTE: In this server, 4 GB UDIMMs run slower than their specified maximum speed of
1600 MHz. In addition, the following rules apply to UDIMMs:
■
■
1 DPC: 1066 MHz is supported at 1.35 V and 1333 MHz is supported at 1.5 V
2 DPC: 1066 MHz is supported at 1.35 V and 1333 MHz is supported at 1.5 V
For more information regarding memory, see CPUs and DIMMs, page 51 .
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) 17
CONFIGURING the SERVER
STEP 4 SELECT RAID CONFIGURATION
NOTE: If you do not select a mezzanine card, a plug-in PCIe RAID card, or one of the embedded RAID upgrade options, you will have an embedded SATA-only RAID controller that supports up to four SATA-only drives (RAID 0, 1, 10)
NOTE: When creating a RAID volume, follow these guidelines:
■
■
■
Use the same capacity for each drive in the volume
Use either all SAS drives or all SATA drives
Use either all HDDs or all SSDs
■
■
■
■
NOTE: The number of RAID groups (virtual drives) supported per controller is as follows:
Embedded RAID = 8
LSI MegaRAID 9266CV-8i RAID controller card = 64
LSI MegaRAID 9285CV-8e RAID controller card = 64
Cisco UCSC RAID SAS 2008M-8i Mezzanine Card = 16
The RAID controller choices are:
(1) Embedded RAID (on motherboard)
NOTE: The RAID configuration options listed in
are not available if you choose embedded RAID (in this case, you must configure RAID yourself using separate software).
(2) Mezzanine RAID controller cards (not supported in 1-CPU configurations)
(3) Plug-in PCIe RAID controller cards
Cisco can provide factory-configured RAID systems depending on the RAID controller chosen and the number of drives ordered. Factory-configured RAID options are listed with each RAID card description.
18 Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
Select RAID Options
■
■
■
■
■
Select one of the following (these choices are dependent on the number of CPUs installed):
One embedded RAID upgrade option for internal drives, or
One mezzanine RAID controller for internal drives, or
One RAID controller for external drives, or
One RAID controller for internal drives, or
One mezzanine RAID controller for internal drives and one RAID controller for external drives
NOTE: For all valid combinations of embedded RAID, mezzanine RAID, and internal/external RAID controller combinations, see
Table 5 Available Embedded RAID Options
Product ID (PID)
RAID Controllers
UCSC-RAID-ROM5
PID Description
UCSC-RAID-ROM55
Onboard RAID, supporting up to 8 internal SAS+SATA drives. This option supports RAID 0, 1, and 10, and operates at 3 Gb/s. Operating systems supported are Windows and Linux only (no VMware support).
Onboard RAID, supporting up to 8 internal SAS+SATA drives. This option supports RAID 0, 1, 5, and 10, and operates at 3 Gb/s. Operating systems supported are Windows and Linux only (no VMware support).
Table 6 Available Mezzanine Card RAID Options
Product ID (PID) PID Description
Mezzanine RAID Controllers (not supported in 1-CPU systems)
UCSC-RAID-11-C220 Cisco UCSC RAID SAS 2008M-8i Mezzanine Card (RAID 0, 1, 5, 10, and 50 supported), operating at 6 Gbs.
■ Supports up to eight internal SAS+SATA drives. SAS and SATA drives can be mixed.
■ Factory-configured RAID options available: RAID 0, 1, 5, and 10 (see the
RAID PIDs section in this table)
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) 19
CONFIGURING the SERVER
Table 6 Available Mezzanine Card RAID Options (continued)
Product ID (PID)
UCSC-RAID-MZ-220
PID Description
Cisco UCSC RAID SAS 2008M-8i Mezzanine Card (RAID 0, 1, 10 supported), operating at 6 Gbs.
■ Supports up to eight internal SAS+SATA drives. SAS and SATA drives can be mixed.
■ Factory-configured RAID options available: RAID 0, 1, and 10 (see the RAID
PIDs section in this table)
■ No data cache backup
Table 7 Available Plug-In PCIe Card RAID Options
Product ID (PID) PID Description
RAID Controllers
Note that plug-in PCIe RAID controllers are installed by default in slot 1 for 1-CPU systems and slot 2 for 2-CPU systems)
UCS-RAID-9266CV LSI MegaRAID SAS 9266CV-8i RAID controller card with data cache backup (RAID
0, 1, 10, 5, 6, 50, 60), operating at 6 Gbs.
■ Supports up to eight internal SAS+SATA drives. SAS and SATA drives can be mixed.
■ Includes a 1 GB Transportable Memory Module (TMM) and a chassis-mounted (remote) supercapacitor for data cache power backup
■ Factory-configured RAID options available: RAID 0, 1, 5, 6, and 10, (see the RAID PIDs section in this table)
UCS-RAID-9285CV-E LSI MegaRAID SAS 9285CV-8e (RAID 0, 1, 5, 6, 10)
■ Supports from one to eight external SAS ports (up to 240 external drives).
NOTE: For SAS 9285CV-8e external drive enclosure support, see the compatibility list (enclosure section) at the following link: http://tinyurl.com/b4etshk
Cisco is able to support customers with questions related to the SAS
9285CV-8e RAID card; however, customers should contact their storage vendor for technical support related to enclosure/JBOD.
■ Includes an chassis-mount (remote) supercapacitor to power on-board
1 GB flash-backed write cache.
■ Factory-configured RAID options: RAID 0, 1, 5, 6, 10 (see the RAID
Configuration section in this table)
20 Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
Table 7 Available Plug-In PCIe Card RAID Options (continued)
Product ID (PID)
Super Capacitor Option
UCS-RAID-CV-SC= LSI CacheVault Power Module for SAS 9266CV-8i. This is a spare supercapacitor.
It is the exact same supercapacitor that ships with the 9266CV-8i and
9285CV-8e cards listed earlier in this table and can be used as a replacement or upgrade part.
RAID Configuration Options (not available for embedded RAID)
R2XX-SRAID0
R2XX-RAID0
Enable Single Disk Raid 0 Setting (for the following PIDs only):
■
■
■
UCS-RAID-9266CV
UCSC-RAID-11-C220
UCSC-RAID-MZ-220
Factory preconfigured RAID striping option
Enable RAID 0 Setting. Requires a minimum of one hard drive.
R2XX-RAID1
PID Description
R2XX-RAID5
R2XX-RAID6
R2XX-RAID10
Factory preconfigured RAID mirroring option
Enable RAID 1 Setting. Requires exactly two drives with the same size, speed, capacity.
Factory preconfigured RAID option
Enable RAID 5 Setting. Requires a minimum of three drives of the same size, speed, capacity.
Factory preconfigured RAID option
Enable RAID 6 Setting. Requires a minimum of four drives of the same size, speed, capacity.
Factory preconfigured RAID option
Enable RAID 10 Setting. Requires a even number of drives (minimum of four drives) of the same size, speed, capacity.
NOTE: Although RAID levels 50 and 60 are not orderable from the factory, they are supported for selected controllers as shown in
Approved Configurations
The C220 M3 SFF server has an 8-drive backplane.
■
■
■
■
■
ROM5 and ROM55 embedded RAID upgrade options support up to 8 drives.
Mezzanine card (UCSC-RAID-11-C220) supports up to 8 drives.
Mezzanine card (UCSC-RAID-MZ-220) supports up to 8 drives.
SAS 9266CV-8i PCIe card supports up to 8 drives.
LSI MegaRAID SAS 9285CV-8e supports up to 8 external SAS ports (240 external drives)
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) 21
CONFIGURING the SERVER
See Table 8 for a summary of the supported RAID configuration options.
Table 8 Supported RAID Configurations 1
Server
C220 M3 SFF
C220 M3 SFF
C220 M3 SFF
C220 M3 SFF
C220 M3 SFF
C220 M3 SFF
#
CPUs
1
1
1
2
2
2
Embedded
RAID
Enabled
Not allowed
Not allowed
Enabled
Not allowed
Not allowed
Mezz
RAID
Not allowed
Not allowed
Not allowed
Not allowed
Installed
Not
2 allowed
7
Internal
PCIe RAID
#1 3
Not allowed
Installed slot 1
(default)
Not allowed
Not allowed
Not allowed
Installed slot 2
(default)
Internal
PCIe
RAID #2
Not allowed
Not allowed
Not allowed
Not allowed
Not allowed
Not allowed
4
External
PCIe
RAID 5
# Drives
Supported PCIe Slots
6
1 2
Not allowed
8 internal A U
Not allowed
Installed slot 1
Not allowed
Card absent
Not allowed
8 internal
240 external
8 internal
8 internal
8 internal
O
O
A
A
A
U
U
A
A
O
C220 M3 SFF
C220 M3 SFF
2
2
Not allowed
Not allowed
Card absent
Installed
Not allowed
Not allowed
Not allowed
Not allowed
Installed slot 1 or slot 2
Installed slot 1 or slot 2
240 external
8 internal
240 external
A
A
Notes . . .
1. You cannot mix RAID types. You can use either embedded RAID, mezzanine RAID, or PCIe RAID, but only one at a time.
2. Never disable OPROM for the mezzanine slot if the mezzanine card is present, or the system will not boot. If you remove the mezzanine card and disable its OPROM, you can boot from another bootable device (RAID card, embedded RAID, or from SAN via an HBA or CNA card). When you boot from a device, make sure its OPROM is enabled, it is in the proper boot sequence, and its BIOS is configured for a bootable device.
3. If you want to boot from a device other than the 9266CV-8i MegaRAID PCIe card, you can leave the card installed. Just disable the OPROM for its slot, and the system will boot even with the card installed.
4. Dual RAID controllers are not supported in this server
5. External RAID card is the 9285CV-8e. The 9285CV-e can be installed simultaneously with one mezzanine RAID controller card. It cannot be used simultaneously with an internal RAID controller card (9266CV-8i) because of mounting space limitations for the supercap (there is space to mount only one supercap).
6. A = available slot, O = occupied slot, U = unsupported slot (slot 2 is not supported in 1-CPU systems)
7. The mezzanine slot is not supported in 1-CPU systems
A
A
22 Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
Caveats
■
■
Note that only a single Cisco VIC card (the half-height Cisco VIC 1225 PCIe card) is supported and it must be installed in the full-height PCIe slot (slot 1) on riser 1. So take this into account when populating RAID controller cards.
You can choose an optional RAID configuration (RAID 0, 1, 5, 6, or 10), which is preconfigured at the factory. The RAID level you choose must be an available RAID choice for the controller selected. RAID levels 50 and 60 are supported, although they are not available as configuration options.
NOTE: For more important information regarding RAID combinations and support,
and RAID Option ROM (OPROM) Settings, page 58
.
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) 23
CONFIGURING the SERVER
STEP 5 SELECT HARD DISK DRIVES (HDDs) or SOLID STATE DRIVES
(SSDs)
■
■
■
The standard disk drive features are:
2.5-inch small form factor
Hot-pluggable
Sled-mounted
Select Drives
The available drives are listed in Table 9 .
Table 9 Available Hot-Pluggable Sled-Mounted HDDs and SSDs
Product ID (PID)
HDDs
A03-D1TBSATA
UCS-HDD900GI2F106
A03-D600GA2
A03-D500GC3
UCS-HDD300GI2F105
A03-D300GA2
A03-D146GC2
SSDs
UCS-SD400G0KA2-G
UCS-SD300G0KA2-E
UCS-SD200G0KA2-E
UCS-SD100G0KA2-G
UCS-SD100G0KA2-E
PID Description
1TB SATA 7.2K RPM SFF HDD
900 GB 6Gb SAS 10K RPM SFF HDD
600 GB 6Gb SAS 10K RPM SFF HDD
500 GB SATA 7.2K RPM SFF HDD
300 GB 6Gb SAS 15K RPM SFF HDD
300 GB 6Gb SAS 10K RPM SFF HDD
146 GB 6Gb SAS 15K RPM SFF HDD
400 GB SATA 2.5" Enterprise Value SSD
300 GB SATA 2.5" Enterprise Performance SATA SSD
200 GB SATA 2.5" Enterprise Performance SATA SSD
100 GB SATA 2.5" Enterprise Value SSD
100 GB SATA 2.5" Enterprise Performance SATA SSD
NOTE: When creating a RAID volume, follow these guidelines:
■
■
■
Use the same capacity for each drive in the volume
Use either all SAS drives or all SATA drives
Use either all HDDs or all SSDs
Drive
Type
SATA
SATA
SATA
SATA
SATA
SAS
SAS
SAS
SATA
SAS
SAS
SATA
Capacity
400 GB
300 GB
200 GB
100 GB
100 GB
1 TB
900 GB
600 GB
500 GB
300 GB
300 GB
146 GB
24 Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
Approved Configurations
(1) Onboard RAID, Mezzanine Cards, and all Plug-In RAID Controllers
■
■
If you have not selected an onboard RAID upgrade option (ROM5 or ROM55), a mezzanine card, or a plug-in RAID controller for internal drives (LSI MegaRAID SAS 9266CV-8i), you may select up to 4 SATA-only drives, which will be controlled with the embedded SATA-only RAID controller.
Otherwise, select up to eight SAS+SATA drives listed in Table 9 . You can mix SAS and SATA
drives.
Caveats
■ You can mix SATA and SAS drives.
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) 25
CONFIGURING the SERVER
STEP 6 SELECT PCIe OPTION CARD(s)
■
■
■
The standard PCie card offerings are:
Converged Network Adapters (CNAs)
Network Interface Cards (NICs)
Host Bus Adapters (HBAs)
Select PCIe Option Cards
The available PCIe option cards are listed in Table 10 .
Table 10 Available PCIe Option Cards
Product ID (PID) PID Description
Converged Network Adapters (CNAs)
UCSC-PCIE-BSFP Broadcom 57712 Dual Port 10Gb SFP+ w/TOE iSCSI
UCSC-PCIE-CSC-02
UCSC-PCIE-C10T-02
Cisco VIC 1225 Dual Port 10Gb SFP+ CNA
Cisco VIC 1225T Dual Port 10GBaseT CNA
UCSC-PCIE-ESFP
UCSC-PCIE-QSFP
Emulex OCe11102-FX dual-port 10 GbE FCoE CNA (Gen 3 CNA)
Qlogic QLE8242-CU dual-port 10 GbE FCoE CNA
UCSC-PCIE-B3SFP Broadcom 57810 10Gb A-FEX SFP+
Network Interface Cards (NICs)
N2XX-ABPCI01-M3
N2XX-ABPCI03-M3
N2XX-AIPCI01
UCSC-PCIE-ITG
Broadcom 5709 Dual Port 1Gb w/TOE iSCSI for M3 Servers
Broadcom 5709 Quad Port 1Gb w/TOE iSCSI for M3 Servers
Intel X520 Dual Port 10Gb SFP+ Adapter
Intel X540 Dual Port 10GBase-T Adapter
UCSC-PCIE-IRJ45
UCSC-PCIE-BTG
Intel i350 Quad Port 1Gb Adapter
Broadcom 57712 Dual Port 10GBASE-T w/TOE iSCSI
Host Bus Adapters (HBAs)
N2XX-AEPCI03 Emulex LPe 11002 Dual Port 4Gb Fibre Channel HBA
N2XX-AEPCI05
N2XX-AQPCI03
N2XX-AQPCI05
Emulex LPe 12002 Dual Port 8Gb Fibre Channel HBA
Qlogic QLE2462 Dual Port 4Gb Fibre Channel HBA
Qlogic QLE2562 Dual Port 8Gb Fibre Channel HBA
Card
Height
Half
Half
Half
Half
Half
Half
Half
Half
Half
Half
Half
Half
Half
Half
Half
Half
26 Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
Approved Configurations
(1) No RAID controller plug-in card
■ If you did not choose a plug-in RAID controller (for example, you are using embedded RAID or a mezzanine RAID controller), you can select up to one PCie option card (for 1-CPU systems) or two PCie option cards (for 2-CPU systems) listed in
(2) One RAID controller plug-in card
■ If you selected a plug-in PCIe RAID controller, you can select none of the optional PCIe cards
(for 1-CPU systems) or one of the optional PCIe cards (for 2-CPU systems) listed in
NOTE: If a plug-in RAID controller card is installed, any optional PCIe card you select will be installed in the full-height slot. RAID controllers are always installed in the half-height slot.
Caveats
■
■
■
■
■
For 1-CPU systems:
— Only the full-height PCIe slot (slot 1) is supported
— Neither PCIe slot 2 nor the mezzanine card slot are supported
— Only a single VIC card (the Cisco VIC 1225 PCIe card) is supported and it must be installed in slot 1 (the full-height slot).
For 2-CPU systems:
— Both PCIe slots (slots 1 and 2) and the mezzanine card slot are supported
— Only a single VIC card (the half-height Cisco VIC 1225 PCIe card) is supported and it must be installed in slot 1 (the full height slot).
All PCIe cards will fit in either slot.
Other considerations for the Cisco VIC 1225:
— Supports 10G SFP+ optical and copper twinax connections
— The server supports installation of one Cisco VIC 1225 card and it is supported only in PCIe slot 1.
— Requires that the server has CIMC firmware version 1.4(6) or later installed. There is a heartbeat LED on the top of the card that indicates when firmware is active.
— To use this card for UCS integration (Cisco UCS Manager mode) with Cisco UCS
Manager 2.1(0) or later, the minimum card-firmware and uboot image level is
2.1(0.306).
To help ensure that your operating system is compatible with the card you have selected, check the Hardware Compatibility List at this URL: http://www.cisco.com/en/US/products/ps10477/prod_technical_reference_list.html
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) 27
CONFIGURING the SERVER
STEP 7 ORDER OPTIONAL NETWORK CARD ACCESSORIES
Copper twinax cables and SFP optical modules may be ordered to support the two-port network cards that are available with the server.
Choose Optional Twinax Cables
lists the copper twinax cables available for the PCIe cards. You can choose cable lengths of 1, 3, 5, 7, or 10 meters. The two longer cables (7 and 10 meters) are active, which means that they contain active components within the SFP+ housing to improve signal quality.
Table 11 Available Twinax Cables
Product ID (PID)
SFP-H10GB-CU1M
SFP-H10GB-CU3M
SFP-H10GB-CU5M
SFP-H10GB-ACU7M
SFP-H10GB-ACU10M
PID Description
10GBASE-CU SFP+ Cable (1 M)
10GBASE-CU SFP+ Cable (3 M)
10GBASE-CU SFP+ Cable (5 M)
10GBASE-CU SFP+ Cable (7 M)
10GBASE-CU SFP+ Cable (10 M)
Approved Configurations
(1) Choose Up to Two Twinax Cables for Each Network Card Ordered
■ You may choose one or two twinax cables for each network card ordered. The cables can be different lengths; however, you would normally order two cables of equal lengths to connect to the primary and redundant network switching equipment.
Caveats
The twinax cables listed in
Table 11 can be ordered only for the following PCIe cards:
— UCS-PCIE-BSFP (Broadcom 57712)
— N2XX-AIPCI01 (Intel Dual Port Ethernet X520)
— UCSC-PCIE-CSC-02 (Cisco VIC 1225 Dual Port 10Gb SFP+ CNA)
28 Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
Choose Optional SFP Modules
Optical Cisco SFP+ modules are listed in Table 12 .
Table 12 Available SFP Modules
Product ID (PID)
SFP-10G-SR
DS-SFP-FC8G-SW
PID Description
10GBASE-SR SFP+ Module
850 nm, multimode, SR, 3.3V, LC connector, with Digital Optical Monitoring
8 Gbit SFP+ Module
850 nm, multimode, SR, 3.3V, LC connector, with Digital Optical Monitoring
Approved Configurations
(1) Choose Up to Two SFP+ Modules for Each Network Card Ordered
■ You may choose one or two SFP+ optical modules cables for each network card ordered. You would normally order two modules for connecting to the primary and redundant network switching equipment. With the SFP+ optical modules, you can use common fiber optic cables, widely available.
for typical SFP+ and twinax connections to the network cards.
Caveats
The SFP-10G-SR optical module listed in
should be ordered only for the following PCIe cards, as they do not come by default with any optical modules:
— UCSC-PCIE-BSFP (Broadcom 57712)
— N2XX-ABPCI02 (Broadcom 57711)
— UCSC-PCIE-CSC-02 (Cisco VIC 1225 Dual Port 10Gb SFP+ CNA)
The DS-SFP-FC8G-SW optical module listed in
should be ordered only for the following
PCIe cards, as they do not come by default with any optical modules:
— N2XX-AEPCI05 (Emulex LPe 12002, 8Gb dual-port Fibre Channel HBA)
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) 29
CONFIGURING the SERVER
Figure 5 Network Card Connections
30 Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
STEP 8 ORDER POWER SUPPLY
The C220 M3 SFF server accommodates two power supplies. A lightly loaded server can operate from one 650 W power supply. A fully loaded server might need to be powered with two 450 W or two 650 W power supplies (see
). Use the power calculator at the following link to determine the needed power based on the options chosen (CPUs, drives, memory, and so on): https://express.salire.com/Go/Cisco/Cisco-UCS-Power-Calculator.aspx
Table 13 Power Supply PIDs
Product ID (PID)
UCSC-PSU-450W
PID Description
450 W power supply
UCSC-PSU-650W 650 W power supply
NOTE: In a two power supply server, both power supplies must be identical.
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) 31
CONFIGURING the SERVER
STEP 9 SELECT AC POWER CORD(s)
Using Table 14 , select the appropriate AC power cords. You can select a minimum of no power
cords and a maximum of two. If you select the option R2XX-DMYMPWRCORD, no power cord is shipped with the server.
Table 14 Available Power Cords
Product ID (PID) PID Description
R2XX-DMYMPWRCORD No power cord (dummy PID to allow for a no power cord option)
CAB-N5K6A-NA Power Cord, 200/240V 6A, North
America
Images
Not applicable
Plug: NEMA 6-15P
Cordset rating: 10 A, 250 V
Length: 8.2 ft
Connector:
IEC60320/C13
CAB-AC-L620-C13 AC Power Cord, NEMA L6-20 - C13,
2M/6.5ft
CAB-C13-CBN CABASY,WIRE,JUMPER CORD, 27" L,
C13/C14, 10A/250V
CAB-C13-C14-2M CABASY,WIRE,JUMPER CORD, PWR,
2 Meter, C13/C14,10A/250V
CAB-C13-C14-AC CORD,PWR,JMP,IEC60320/C14,IEC6
0320/C13, 3.0M
32 Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
Table 14 Available Power Cords
Product ID (PID)
SFS-250V-10A-AR
CAB-9K10A-AU
PID Description
Power Cord, SFS, 250V, 10A,
Argentina
Power Cord, 250VAC 10A 3112 Plug,
Australia
Images
Plug:
EL 219
(IRAM 2073)
2500 mm
Cordset rating: 10 A, 250/500 V MAX
Length: 8.2 ft
Connector:
EL 701
(IEC60320/C13)
Plug:
EL 210
Cordset rating: 10 A, 250 V/500 V MAX
Length: 2500mm
Connector:
EL 701C
(EN 60320/C15)
(BS 1363A) 13 AMP fuse
SFS-250V-10A-CN Power Cord, SFS, 250V, 10A, China
Plug:
EL 218
(CCEE GB2009)
Cordset rating 10A, 250V
(2500 mm)
Connector:
EL 701
(IEC60320/C13)
CAB-250V-10A-CN AC Power Cord - 250V, 10A - PRC
CAB-9K10A-EU
SFS-250V-10A-ID
SFS-250V-10A-IS
Power Cord, 250VAC 10A CEE 7/7
Plug, EU
Power Cord, SFS, 250V, 10A, India
Plug:
EL 208
Power Cord, SFS, 250V, 10A, Israel
EL-212
16A
250V
Plug:
EL 212
(SI-32)
Plug:
M2511
Cordset rating: 10A/16 A, 250 V
Length: 8 ft 2 in. (2.5 m)
Connector:
VSCC15
Cordset rating 16A, 250V
(2500mm)
Connector:
EL 701
Cordset rating 10A, 250V/500V MAX
(2500 mm)
Connector:
EL 701B
(IEC60320/C13)
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) 33
CONFIGURING the SERVER
Table 14 Available Power Cords
Product ID (PID)
CAB-9K10A-IT
PID Description
Power Cord, 250VAC 10A CEI
23-16/VII Plug, Italy
Images
Plug:
I/3G
(CEI 23-16)
Cordset rating: 10 A, 250 V
Length: 8 ft 2 in. (2.5 m)
Connector
C15M
(EN60320/C15 )
CAB-9K10A-SW Power Cord, 250VAC 10A MP232
Plug, Switzerland
Plug:
MP232-R
Cordset rating: 10 A, 250 V
Length: 8 ft. 2 in (2.5 m)
Connector:
IEC 60320 C15
CAB-9K10A-UK Power Cord, 250VAC 10A BS1363
Plug (13 A fuse), UK
Plug:
EL 210
Cordset rating: 10 A, 250 V/500 V MAX
Length: 2500mm
Connector:
EL 701C
(EN 60320/C15)
(BS 1363A) 13 AMP fuse
CAB-9K12A-NA Power Cord, 125VAC 13A NEMA
5-15 Plug, North America
CAB-JPN-3PIN Power Cord 3PIN, Japan Image not available
34 Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
STEP 10 ORDER OPTIONAL REVERSIBLE CABLE MANAGEMENT ARM
The reversible cable management arm mounts on either the right or left slide rails at the rear of the server and is used for cable management. Use
to order a cable management arm.
Table 15 Cable Management Arm
Product ID (PID)
UCSC-CMA1
PID Description
Cable Management Arm for C220 rack servers
For more information about the cable management arm, see the Cisco UCS C220 M3 Installation
and Service Guide at this URL: http://www.cisco.com/en/US/docs/unified_computing/ucs/c/hw/C220/install/C220.pdf
NOTE: All UCS C220 M3 servers ship with a tool-less rail kit.
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) 35
CONFIGURING the SERVER
STEP 11 ORDER A TRUSTED PLATFORM MODULE (OPTIONAL)
Trusted Platform Module (TPM) is a computer chip (microcontroller) that can securely store artifacts used to authenticate the platform (server). These artifacts can include passwords, certificates, or encryption keys. A TPM can also be used to store platform measurements that help ensure that the platform remains trustworthy. Authentication (ensuring that the platform can prove that it is what it claims to be) and attestation (a process helping to prove that a platform is trustworthy and has not been breached) are necessary steps to ensure safer computing in all environments.
The TPM ordering information is listed in Table 16 .
Table 16 Trusted Platform Module
Product ID (PID)
UCSX-TPM1-001
PID Description
Trusted Platform Module
36 Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
STEP 12 ORDER CISCO FLEXIBLE FLASH SD CARD MODULE (OPTIONAL)
You can order one optional preloaded 16 GB Cisco Flexible Flash secure digital (SD) card. This SD card contains preloaded software for simplified server operation. The ordering information is listed in
.
Table 17 Secure Digital (SD) Card (preloaded with software)
Product ID (PID)
UCSC-SD-16G-C220
PID Description
16GB SD Card for C220 servers
See Figure 6 on page 50 for the location of the SD cards. There are two locations, SD1 and SD2.
NOTE: You can order an optional second blank SD card. The PID for the second SD
(blank) card is shown in Table 18 .
Table 18 Second Secure Digital (SD) Card (blank)
Product ID (PID)
UCSC-SD-16G
PID Description
16GB SD Card (optional)
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) 37
CONFIGURING the SERVER
STEP 13 ORDER OPTIONAL USB 2.0 DRIVE
You can order one optional USB 2.0 drive. The USB drive ordering information is listed in
.
Table 19 USB 2.0 Drive
Product ID (PID)
UCS-USBFLSH-S-4GB
PID Description
4GB Flash USB Drive (shorter length) for all servers except C260
for the location of the USB connector.
38 Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
STEP 14 SELECT OPERATING SYSTEM
Several operating systems are available from which to choose. Select one of the operating systems shown in
.
Table 20 Operating Systems
PID Description Product ID (PID)
SUSE Linux Enterprise Server
SLES-1A SLES/1yr subscription/svcs required/0 media
SLES-3A SLES/3yr subscription/svcs required/0 media
Red Hat Enterprise Linux
RHEL-2S-1G-1A RHEL/2 Socket/1 Guest/1Yr Svcs Required
RHEL-2S-1G-3A
RHEL-2S-4G-1A
RHEL-2S-4G-3A
RHEL-2S-UG-1A
RHEL-2S-UG-3A
RHEL Add-Ons
RHEL/2 Socket/1 Guest/3Yr Svcs Required
RHEL/2 Socket/4 Guest/1Yr Svcs Required
RHEL/2 Socket/4 Guest/3Yr Svcs Required
RHEL/2 Socket/U Guest/1Yr Svcs Required
RHEL/2 Socket/U Guest/3Yr Svcs Required
RHEL-HA-2S-1A
RHEL-RS-2S-1A
RHEL-SFS-2S-1A
RHEL-HA-2S-3A
RHEL-RS-2S-3A
RHEL Option/High-Availability/2 Socket/1Yr Svcs Required
RHEL Option/Resilient w/Ha /2 Socket/1 Yr Svcs Required
RHEL Option/Scalable File System/2 Socket/1 Yr Svcs Required
RHEL Option/High-Availability/2 Socket/3Yr Svcs Required
RHEL Option/Resilient Storage w/ HA /2 Socket/3 Yr Svcs Reqd
RHEL Option/Scalable File System/2 Socket/3 Yr Svcs Required RHEL-SFS-2S-3A
Windows Server
MSWS-08R2-STHV Windows Svr 2008 ST media R2 ST (1-4CPU, 5CAL)
MSWS-08R2-ENHV Windows Svr 2008 EN media R2 EN (1-8CPU, 25CAL)
MSWS-08R2-DCHV2S Windows Svr 2008 R2-2 CPU-Data Center
MSWS-08R2-DCHV4S Windows Svr 2008 R2-4 CPU-Data Center
VMWare Server
VMW-VS5-STD-1A
VMW-VS5-STD-2A
VMware vSphere 5 Standard for 1 Processor, 1 Year, Support Required
VMware vSphere 5 Standard for 1 Processor, 2 Year, Support Required
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) 39
CONFIGURING the SERVER
Table 20 Operating Systems (continued)
PID Description Product ID (PID)
VMW-VS5-STD-3A
VMW-VS5-STD-4A
VMW-VS5-STD-5A
VMW-VS5-ENT-1A
VMW-VS5-ENT-2A
VMW-VS5-ENT-3A
VMW-VS5-ENT-4A
VMW-VS5-ENT-5A
VMware vSphere 5 Standard for 1 Processor, 3 Year, Support Required
VMware vSphere 5 Standard for 1 Processor, 4 Year, Support Required
VMware vSphere 5 Standard for 1 Processor, 5 Year, Support Required
VMware vSphere 5 Enterprise for 1 Processor, 1 Year Support Required
VMware vSphere 5 Enterprise for 1 CPU, 2 Yr Support Required
VMware vSphere 5 Enterprise for 1 CPU, 3 Yr Support Required
VMware vSphere 5 Enterprise for 1 Processor, 4 Year Support Required
VMware vSphere 5 Enterprise for 1 CPU, 5 Yr Support Required
VMW-VS5-ENTP-1A VMware vSphere 5 Enterprise Plus for 1 Processor, 1 Year Support Required
VMW-VS5-ENTP-2A VMware vSphere 5 Enterprise Plus for 1 CPU, 2 Yr Support Required
VMW-VS5-ENTP-3A VMware vSphere 5 Enterprise Plus for 1 Processor, 3 Year Support Required
VMW-VS5-ENTP-4A VMware vSphere 5 Enterprise Plus for 1 Processor, 4 Year Support Required
VMW-VS5-ENTP-5A VMware vSphere 5 Enterprise Plus for 1 Processor, 5 Year Support Required
40 Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
STEP 15 SELECT OPERATING SYSTEM MEDIA KIT
Select the optional operating system media listed in
.
Table 21 OS Media
Product ID (PID)
RHEL-6
SLES-11
MSWS-08R2-STHV-RM
MSWS-08R2-ENHV-RM
MSWS-08R2-DCHV-RM
PID Description
RHEL 6 Recovery Media Only (Multilingual)
SLES 11 media only (multilingual)
Windows Svr 2008 R2 ST (1-4CPU, 5CAL), Media
Windows Svr 2008 R2 EN (1-8CPU, 25CAL), Media
Windows Svr 2008 R2 DC (1-8CPU, 25CAL), Media
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) 41
CONFIGURING the SERVER
STEP 16 SELECT OPTIONAL VALUE-ADDED SOFTWARE
You can select from a variety of value-added software listed in Table 22 .
Table 22 Value Added Software
Product ID (PID) PID Description
BMC-SE-4C
BMC-SE-6C
BMC-SE-8C
BMC-SE-10C
BMC-AE-4C
BMC-AE-6C
BMC-AE-8C
BMC-AE-10C
BMC-002
BMC-012
BMC BladeLogic Standard Edition, 4 Cores, Support Required
BMC BladeLogic Standard Edition, 6 Cores, Support Required
BMC BladeLogic Standard Edition, 8 Cores, Support Required
BMC BladeLogic Standard Edition, 10 Cores, Support Required
BladeLogic Advanced Edition, 4 Cores, Support Required
BMC BladeLogic Advanced Edition, 6 Cores, Support Required
BMC BladeLogic Advanced Edition, 8 Cores, Support Required
BMC BladeLogic Advanced Edition, 10 Cores, Support Required
BMC BladeLogic CM for Physical Cisco Servers
BMC BPPM Per Server
VMW-VC5-STD-1A
VMW-VC5-STD-2A
VMW-VC5-STD-3A
VMW-VC5-STD-4A
VMW-VC5-STD-5A
N1K-VLEM-UCS-1
VMware vCenter 5 Standard for 1 Processor, 1 Year, Support Required
VMware vCenter 5 Standard for 1 Processor, 2 Year, Support Required
VMware vCenter 5 Standard for 1 Processor, 3 Year, Support Required
VMware vCenter 5 Standard for 1 Processor, 4 Year, Support Required
VMware vCenter 5 Standard for 1 Processor, 5 Year, Support Required
Nexus 1000V License PAK for 1 Virtual Ethernet module
N1K-CSK9-UCS-404 Nexus 1000V VSM Virtual Appliance Software
42 Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
STEP 17 SELECT SERVICE and SUPPORT LEVEL
■
■
■
■
■
A variety of service options are available, as described in this section.
Unified Computing Warranty, No Contract
If you have noncritical implementations and choose to have no service contract, the following coverage is supplied:
Three-year parts coverage.
Next business day (NBD) onsite parts replacement eight hours a day, five days a week.
90-day software warranty on media.
Ongoing downloads of BIOS, drivers, and firmware updates.
UCSM updates for systems with Unified Computing System Manager. These updates include minor enhancements and bug fixes that are designed to maintain the compliance of UCSM with published specifications, release notes, and industry standards.
SMARTnet for UCS
For support of the entire Unified Computing System, Cisco offers the Cisco SMARTnet for UCS
Service. This service provides expert software and hardware support to help sustain performance and high availability of the unified computing environment. Access to Cisco
Technical Assistance Center (TAC) is provided around the clock, from anywhere in the world.
For UCS blade servers, there is Smart Call Home, which provides proactive, embedded diagnostics and real-time alerts. For systems that include Unified Computing System Manager, the support service includes downloads of UCSM upgrades. The Cisco SMARTnet for UCS Service includes flexible hardware replacement options, including replacement in as little as two hours.
There is also access to Cisco's extensive online technical resources to help maintain optimal efficiency and uptime of the unified computing environment. You can choose a desired service listed in
.
Table 23 Cisco SMARTnet for UCS Service
Product ID (PID) On Site? Description
CON-PREM-C220M3SF Yes
CON-OSP-C220M3SF
CON-OSE-C220M3SF
Yes
Yes
CON-OS-C220M3SF Yes
CON-S2P-C220M3SF No
CON-SNTP-C220M3SF No
CON-SNTE-C220M3SF
CON-SNT-C220M3SF
No
No
ONSITE 24X7X2 UCS C220 M3 SFF
ONSITE 24X7X4 UCS C220 M3 SFF
ONSITE 8X5X4 UCS C220 M3 SFF
ONSITE 8X5XNBD UCS C220 M3 SFF
SMARTNET 24X7X2 UCS C220 M3 SFF
SMARTNET 24X7X4 UCS C220 M3 SFF
SMARTNET 8X5X4 UCS C220 M3 SFF
SMARTNET 8X5XNBD UCS C220 M3 SFF
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) 43
CONFIGURING the SERVER
SMARTnet for UCS Hardware Only Service
For faster parts replacement than is provided with the standard Cisco Unified Computing System warranty, Cisco offers the Cisco SMARTnet for UCS Hardware Only Service. You can choose from two levels of advanced onsite parts replacement coverage in as little as four hours. SMARTnet for UCS Hardware Only Service provides remote access any time to Cisco support professionals who can determine if a return materials authorization (RMA) is required. You can choose a service listed in
Table 24 SMARTnet for UCS Hardware Only Service
Product ID (PID)
CON-UCW7-C220M3SF
CON-UCW5-C220M3SF
Service
Level GSP
UCW7
UCW5
On
Site?
Yes
Yes
Description
UCS HW 24X7X4OS UCS C220 M3 SFF
UC PLUS 8X5XNBDOS UCS C220 M3 SFF
Unified Computing Partner Support Service
Cisco Partner Support Service (PSS) is a Cisco Collaborative Services service offering that is designed for partners to deliver their own branded support and managed services to enterprise customers. Cisco PSS provides partners with access to Cisco's support infrastructure and assets to help them:
■
■
■
Expand their service portfolios to support the most complex network environments
Lower delivery costs
Deliver services that increase customer loyalty
Partner Unified Computing Support Options enable eligible Cisco partners to develop and consistently deliver high-value technical support that capitalizes on Cisco intellectual assets.
This helps partners to realize higher margins and expand their practice.
PSS is available to all Cisco PSS partners, but requires additional specializations and requirements. For additional information, see the following URL:
■
■ www.cisco.com/go/partnerucssupport
The two Partner Unified Computing Support Options include:
Partner Support Service for UCS
Partner Support Service for UCS Hardware Only
44 Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
Partner Support Service for UCS provides hardware and software support, including triage support for third party software, backed by Cisco technical resources and level three support.
.
Table 25 Partner Support Service for UCS
Product ID (PID)
CON-PSJ1-C220M3SF
CON-PSJ2-C220M3SF
CON-PSJ3-C220M3SF
CON-PSJ4-C220M3SF
Service
Level
GSP
PSJ1
PSJ2
PSJ3
PSJ4
On
Site?
No
No
No
No
Description
UCS SUPP PSS 8X5XNBD UCS C220 M3 SFF
UCS SUPP PSS 8X5X4 UCS C220 M3 SFF
UCS SUPP PSS 24X7X4 UCS C220 M3 SFF
UCS SUPP PSS 24X7X2 UCS C220 M3 SFF
Partner Support Service for UCS Hardware Only provides customers with replacement parts in as
little as two hours. See Table 26 .
Table 26 Partner Support Service for UCS (Hardware Only)
Product ID (PID)
CON-PSW2-C220M3SF
CON-PSW3-C220M3SF
CON-PSW4-C220M3SF
Service
Level GSP
PSW2
PSW3
PSW4
On
Site?
No
No
No
Description
UCS W PL PSS 8X5X4 UCS C220 M3 SFF
UCS W PL PSS 24X7X4 UCS C220 M3 SFF
UCS W PL PSS 24X7X2 UCS C220 M3 SFF
Unified Computing Combined Support Service
■
■
■
■
Combined Services makes it easier to purchase and manage required services under one contract. SMARTnet services for UCS help increase the availability of your vital data center infrastructure and realize the most value from your unified computing investment. The more benefits you realize from the Cisco Unified Computing System (Cisco UCS), the more important the technology becomes to your business. These services allow you to:
■
Optimize the uptime, performance, and efficiency of your UCS
Protect your vital business applications by rapidly identifying and addressing issues
Strengthen in-house expertise through knowledge transfer and mentoring
Improve operational efficiency by allowing UCS experts to augment your internal staff resources
Enhance business agility by diagnosing potential issues before they affect your operations
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) 45
CONFIGURING the SERVER
You can choose a service listed in
.
Table 27 UCS Computing Combined Support Service
Product ID (PID)
Service
Level GSP
On
Site?
Description
CON-NCF2C220M3SF
CON-NCF2PC220M3SF
NCF2
NCF2P
CON-NCF4PC220M3SF NCF4P
CON-NCF4SC220M3SF NCF4S
CON-NCFCSC220M3SF NCFCS
CON-NCFEC220M3SF NCFE
CON-NCFPC220M3SF NCFP
CON-NCFTC220M3SF NCFT
Yes
No
No
No
No
Yes
Yes
Yes
CMB SPT SVC 24X7X2 UCS C220 M3 SFF
CMB SPT SVC 24X7X2OS
UCS C220 M3 SFF
CMB SPT SVC 24X7X4OS
UCS C220 M3 SFF
CMB SPT SVC 8X5X4OS
UCS C220 M3 SFF
CMB SPT SVC 8X5XNBDOS
UCS C220 M3 SFF
CMB SPT SVC 8X5X4
UCS C220 M3 SFF
CMB SPT SVC 24X7X4 UCS C220 M3 SFF
CMB SPT SVC 8X5XNBD
UCS C220 M3 SFF
Unified Computing Drive Retention Service
With the Cisco Unified Computing Drive Retention (UCDR) Service, you can obtain a new disk drive in exchange for a faulty drive without returning the faulty drive. In exchange for a Cisco replacement drive, you provide a signed Certificate of Destruction (CoD) confirming that the drive has been removed from the system listed, is no longer in service, and has been destroyed.
Sophisticated data recovery techniques have made classified, proprietary, and confidential information vulnerable, even on malfunctioning disk drives. The UCDR service enables you to retain your drives and ensures that the sensitive data on those drives is not compromised, which reduces the risk of any potential liabilities. This service also enables you to comply with regulatory, local, and federal requirements.
If your company has a need to control confidential, classified, sensitive, or proprietary data, you
might want to consider one of the Drive Retention Services listed in Table 28 .
NOTE: Cisco does not offer a certified drive destruction service as part of this service.
Table 28 Drive Retention Service Options
Service Description
Service
Program Name
SMARTnet for UCS
Service with Drive
Retention
UCS DR
Service
Level GSP
UCSD7
UCSD7
Service Level
24x7x4 Onsite
8x5xNBD Onsite
Product ID (PID)
CON-UCSD7-C220M3SF
CON-UCSD5-C220M3SF
46 Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
CONFIGURING the SERVER
Table 28 Drive Retention Service Options (continued)
Service Description
SMARTnet for UCS
HW ONLY+Drive
Retention
Service
Program Name
UCS HW+DR
Service
Level GSP
UCWD7
UCWD5
Service Level
24x7x4 Onsite
8x5xNBD Onsite
Product ID (PID)
CON-UCWD7-C220M3SF
CON-UCWD5-C220M3SF
For more service and support information, see the following URL: http://www.cisco.com/en/US/services/ps2961/ps10312/Unified_Computing_Services_Overview.pdf
For a complete listing of available services for Cisco Unified Computing System, see this URL: http://www.cisco.com/en/US/products/ps10312/serv_group_home.html
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) 47
OPTIONAL STEP - ORDER RACK(s)
OPTIONAL STEP - ORDER RACK(s)
The optional R42610 rack is available from Cisco for the C-Series servers, including the C220 M3
SFF server. This rack is a standard 19-inch rack and can be ordered with a variety of options, as listed in
. Racks are shipped separately from the C220 M3 SFF server.
Table 29 Racks and Rack Options
Product ID (PID)
RACK-UCS 1
PID Description
Cisco R42610 expansion rack, no side panels
RACK-UCS2 1
RACK-BLANK-001
Cisco R42610 standard rack, w/side panels
Filler panels (qty 12), 1U, plastic, toolless
RACK-CBLMGT-001
RACK-CBLMGT-011
RACK-FASTEN-001
RACK-FASTEN-002
RACK-JOIN-001
Cable mgt D rings (qty 10), metal
Cable mgt straps (qty 10), Velcro
Mounting screws (qty 100), M6
Cage nuts (qty 50), M6
Rack joining kit
Notes . . .
1. Use these same base PIDs to order spare racks (available only as next-day replacements).
For more information about the R42610 rack, see RACKS, page 62
.
48 Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
OPTIONAL STEP - ORDER PDU
OPTIONAL STEP - ORDER PDU
An optional power distribution unit (PDU) is available from Cisco for the C-Series rack servers, including theC220 M3 server. This PDU is available in a zero rack unit (RU) style (see
).
Table 30 PDU Options
Product ID (PID)
RP208-30-2P-U-2
PID Description
Zero RU PDU
For more information about the PDU, see PDUs, page 64
.
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) 49
SUPPLEMENTAL MATERIAL
SUPPLEMENTAL MATERIAL
CHASSIS
Figure 6
An internal view of the C220 M3 chassis with the top cover removed is shown in
.
C220 M3 SFF With Top Cover Off
2 3 4 5 6 7 8 9 10
11
SAS1
SAS2
PCIe1
CPU1
1
CPU2
PCIe2
PSU2
12
13
14
15
16
PSU1
18 17
1
2
3
4
5
6
Drives
(hot-swappable, accessed through front panel)
Drive backplane
SuperCap backup unit mounting location
Cooling fans (five)
10
11
12
13
SCU upgrade ROM header (RAID key).
DIMM slots on motherboard (16)
14
15
Trusted platform module socket on motherboard
Standard-profile PCIe riser (PCIe slot 1)
Low-profile PCIe riser (PCIe slot 2)
Cisco Flexible Flash SD socket SD2 on PCIe riser 2
Cisco Flexible Flash SD socket SD1 on PCIe riser 2
Internal USB port
50 Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
SUPPLEMENTAL MATERIAL
7
8
9
CPUs and heatsinks (two)
Integrated RAID on motherboard, and mini-SAS connectors
Mezzanine RAID card, mini-SAS connectors
SAS1 and SAS2
17
18
16 Power supplies (two, hot-swappable access through rear panel)
RTC battery on motherboard
Software RAID 5 header (RAID key).
CPUs and DIMMs
Physical Layout
Each CPU has four DIMM channels:
■
■
CPU1 has channels A, B, C, and D
CPU2 has channels E, F, G, and H
Each DIMM channel has two banks: bank 1 and bank 2. The blue-colored DIMM slots are for bank 1 and the black-colored slots are for bank 2.
As an example, DIMM slots A1, B1, C1, and D1 belong to bank 1, while A2, B2, C2, and D2 belong to bank 2.
right (channels A, B, C, and D) are associated with CPU1, while the DIMM slots on the left (channels E, F, G, and H) are associated with CPU2. The bank 1 (blue) DIMM slots are always located farther away from a CPU than the corresponding bank 2 (black) slots. Bank 1 slots (blue) are populated before bank 2 slots (black).
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) 51
SUPPLEMENTAL MATERIAL
Figure 7 Physical Layout of CPU DIMM Channels and Banks
C1
C2
D1
D2
CPU1
B2
B1
A2
A1
G1
G2
H1
H2
CPU2
F2
F1
E2
E1
52 Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
SUPPLEMENTAL MATERIAL
Memory Population Rules
When considering the memory configuration of your server, you should consider the following items:
■
■
■
■
Each channel has two DIMM slots (for example, channel A = slots A1 and A2).
— A channel can operate with one or two DIMMs installed.
— If a channel has only one DIMM, populate slot 1 first (the blue slot).
When both CPUs are installed, populate the DIMM slots of each CPU identically.
— Fill blue slots in the channels first: A1, E1, B1, F1, C1, G1, D1, H1
— Fill black slots in the channels second: A2, E2, B2, F2, C2, G2, D2, H2
Any DIMM installed in a DIMM socket for which the CPU is absent is not recognized.
Observe the DIMM mixing rules shown in
Table 31 DIMM Rules for C220 M3 Servers
DIMM Parameter
DIMM Size
RDIMM = 4, 8, or 16 GB
Mix Across a Single Bank?
Mix Across Multiple Bank?
LRDIMM = 32 GB
UDIMM = 4 GB
No—Must be same size in the same bank.
You cannot mix 32 GB LRDIMMs with any RDIMM or UDIMM
You cannot mix 4 GB UDIMMs with any RDIMM or LRIMM
Yes—Different banks can use different DIMM sizes (as long as all
DIMMs in a single bank use the same
DIMM size).
You cannot mix 32 GB LRDIMMs with any RDIMM or UDIMM
You cannot mix 4 GB UDIMMs with any RDIMM or LRIMM
DIMM Speed
1333 or 1600 MHz 1 No—Must be same speed in the same bank.
Yes—but if DIMMs of mixed speed are used, the server will clock down to the lowest speed.
DIMM Type
RDIMMs, LRDIMMs, or
UDIMMs
You cannot mix DIMM types You cannot mix DIMM types
DIMMs per Channel (DPC)
1 DPC or 2 DPC
RDIMMs and LRDIMMs run at 1333 MHz at either 1.35 V or 1.5 V
UDIMMs run at 1066 MHz at 1.35 V and 1333 MHz at 1.5 V
Notes . . .
1. Only 1333- and 1600-MHz DIMMs are currently available for the C220 M3 server.
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) 53
SUPPLEMENTAL MATERIAL
Recommended Memory Configuration
This section explains the recommended DIMM population order rules for the C220 M3 server.
■
■
■
■
All DIMMs must be DDR3 DIMMs.
Do not mix:
— DIMMs with different sizes or clock rates in a bank
— RDIMMs and LRDIMMs
— ECC and non-ECC DIMMs
There are blue and black DIMM slots. Populate blue slots first.
When single- and dual-rank DIMMs are populated for 2DPC, always populate the dual-rank
DIMM in the blue DIMM slot and the single-rank DIMM in the black DIMM slot.
Many memory configurations are possible. For best results, follow Table 32 when populating DIMMs.
Table 32 Recommended Memory Configurations 1
Total
System
Memory
Size
32 GB
CPU 1 DIMMs
Blue Slots
Bank 1
(A1, B1,
C1, D1)
4x4 GB
Black Slots
Bank 2
(A2, B2,
C2, D2)
—
CPU 2 DIMMs
Blue Slots
Bank 1
(E1, F1,
G1, H1)
4x4 GB
Black Slots
Bank 2
(E2, F2,
G2, H2)
—
DIMM Max
Operating
Speed
(MHz)
1600
Total
DIMMs in the
System
8
2x8 GB — 2x8 GB — 1600 4
64 GB
96 GB
128 GB
192 GB
256 GB
512 GB
4x4 GB
4x8 GB
4x8 GB
3x16 GB
4x8 GB
4x8 GB
4x16 GB
4x16 GB
4x16 GB
4x16 GB
4x32 GB
4x4 GB
—
2x8 GB
—
4x4 GB
4x8 GB
—
2x16 GB
4x8 GB
4x16 GB
4x32 GB
4x4 GB
4x8 GB
4x8 GB
3x16 GB
4x8 GB
4x8 GB
4x16 GB
4x16 GB
4x16 GB
4x16 GB
4x32 GB
4x4 GB
—
2x8 GB
—
4x4 GB
4x8 GB
—
2x16 GB
4x8 GB
4x16 GB
4x32 GB
1600
1600
1600
1600
1600
1600
1600
1600
1600
1600
1333 2
12
16
16
16
16
8
12
6
16
16
8
Notes . . .
1. Rows marked in yellow indicate best performance.
2. Even though the specified maximum speed of 32 GB LRDIMMs is 1600 MHz, they run at a maximum speed of
1333 MHz in 2DPC configurations.
54 Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
SUPPLEMENTAL MATERIAL
Supported DIMM Populations
The supported DIMM populations are listed in Table 33 .
1 x 8 GB
1 x 16 GB
2 x 4 GB
4 x 4 GB
2 x 8 GB
6 x 4 GB
8 x 4 GB
4 x 8 GB
8 x 4 GB
1 x 32 GB
5 x 8 GB
3 x 16 GB
6 x 8 GB
4x8 GB + 4x4 GB
7 x 8 GB
4 x 16 GB
8 x 8 GB
2 x 32 GB
5 x 16
4x16 GB + 4x4 GB
6 x 16 GB
4x8 GB + 4x16 GB
3 x 32 GB
7 x 16 GB
8 x 16 GB
4 x 32 GB
8 x 32 GB
Table 33 Supported DIMM Configurations
CPU 1 DIMMs
8
2
5
8
6
8
5
3
6
8
7
4
3
7
8
4
8
2
6
8
4
8
1
1
1
2
4
Total DIMMs for CPU 1
CPU 1
Capacity
CPU 2 DIMMs
8 GB
16 GB
8 GB
16 GB
1 x 8 GB
1 x 16 GB
2 x 4 GB
4 x 4 GB
16 GB
24 GB
32 GB
2 x 8 GB
6 x 4 GB
8 x 4 GB
32 GB 4 x 8 GB
32 GB 8 x 4 GB
32 GB 1 x 32 GB
64 GB
64 GB
80 GB
80 GB
96 GB
96 GB
40 GB 5 x 8 GB
48 GB 3 x 16 GB
48 GB 6 x 8 GB
48 GB
56 GB
64 GB
4x8 GB + 4x4 GB
7 x 8 GB
4 x 16 GB
8 x 8 GB
2 x 32 GB
5 x 16
4x16 GB + 4x4 GB
6 x 16 GB
4x8 GB + 4x16 GB
96 GB 3 x 32 GB
112 GB 7 x 16 GB
128 GB 8 x 16 GB
128 GB 4 x 32 GB
256 GB 8 x 32 GB
8
2
5
8
6
8
5
3
6
8
7
4
3
7
8
4
8
2
6
8
4
8
1
1
1
2
4
Total DIMMs for CPU 2
CPU 2
Capacity
Total
Capacity for
2 CPUs
128 GB
128 GB
160 GB
160 GB
192 GB
192 GB
80 GB
96 GB
96 GB
96 GB
112 GB
128 GB
16 GB
32 GB
16 GB
32 GB
32 GB
48 GB
64 GB
64 GB
64 GB
64 GB
192 GB
224 GB
256 GB
256 GB
512 GB
64 GB
64 GB
80 GB
80 GB
96 GB
96 GB
40 GB
48 GB
48 GB
48 GB
56 GB
64 GB
8 GB
16 GB
8 GB
16 GB
16 GB
24 GB
32 GB
32 GB
32 GB
32 GB
96 GB
112 GB
128 GB
128 GB
256 GB
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) 55
SUPPLEMENTAL MATERIAL
Low-Voltage DIMM Considerations
The C220 M3 server can be ordered with dual-voltage (1.5/1.35 V) DIMMs only. Note the following considerations:
■
■
■
Low-voltage DIMMs within the server must have the identical manufacturer, type, speed, and size.
Low-voltage DIMMs and standard-voltage DIMMs can be mixed in the same server. Note that this causes the system BIOS to default to standard-voltage operation (Performance Mode).
That is, the server cannot operate in Power Saving Mode unless all DIMMs are low-voltage
DIMMs.
CPUs that have a maximum memory frequency less than 1333 MHz support low-voltage
DIMMs operating in Power Saving Mode only, and do not support Performance Mode.
56 Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
SUPPLEMENTAL MATERIAL
RAID Details
The available RAID configurations are shown in this section.
(1) 1-CPU Configurations
Mezzanine cards are not supported for 1-CPU configurations, Therefore, only the following RAID controllers are supported for single-CPU configurations. Select one of these:
■
■
■
An embedded RAID controller (on motherboard) from Table 5 on page 19
One internal drive RAID controller (slot 1 only) from Table 7 on page 20
One external drive RAID controller (slot 1 only) from
NOTE: PCIe slot 2 is not supported for 1-CPU configurations
NOTE: In 1-CPU configurations, PCIe slot 1 is the default slot supported for an internal drive RAID controller. PCIe slots 1 or 2 can be used for one external drive
RAID controller or for PCIe expansion cards. You can change the default card slot for a RAID controller to a different slot by going into the BIOS and reconfiguring the option ROM (OPROM) settings.
You may also select an appropriate optional RAID configuration listed in
(2) 2-CPU Configurations
Select one of the following:
■
■
■
■
■
An embedded RAID controller (on motherboard) from Table 5 on page 19
One mezzanine RAID controller from
One internal drive RAID controller (slot 2) from
One external drive RAID controller (slot 1 or 2) from
One mezzanine RAID controller from
and one external drive RAID
controller (slot 1 or 2) from Table 7 on page 20
NOTE: In 2-CPU configurations, PCIe slot 2 is the default slot supported for an internal drive RAID controller. Slot 1 or slot 2 can be used for one external drive RAID controller or PCIe expansion cards. You can change the default card slot for a RAID controller to a different slot by going into the BIOS and reconfiguring the option ROM
(OPROM) settings.
You may also select an appropriate optional RAID configuration listed in
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) 57
SUPPLEMENTAL MATERIAL
RAID Option ROM (OPROM) Settings
The server contains an Option ROM (OPROM) for the PCIe slots. The server has a finite amount of option
ROM with which it can boot up devices. Go into the BIOS and disable the OPROM on the PCIe slots not used for booting so that resources are available for the slots that are used for booting. An example OPROM BIOS screen is shown in
.
Figure 8 Example BIOS Screen for OPROM
58 Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
SUPPLEMENTAL MATERIAL
Upgrade and Servicing-Related Parts
This section lists the upgrade and servicing-related parts you may need during the life of your server. Some of these parts are configured with every server, and some may be ordered when needed or may be ordered and kept on hand as spares for future use. See
.
Table 34 Upgrade and Servicing-related Parts for UCS C220 M3 SFF Server
Spare Product ID (PID)
N20-BBLKD=
UCSC-CABLE1=
UCSC-PCIF-01H=
UCSC-PCIF-01F=
UCSC-HS-C220M3=
UCSC-AIRBAF-C220=
N20-MBLIBATT=
UCS-RAID-BBU=
UCS-RAID-CV-SC=
UCSC-PSU-BLKP=
UCSC-CMA1=
UCSC-RAIL1=
UCSC-RAIL1-I=
UCSC-SD-16G-C220=
UCS-SD-16G=
UCS-USBFLSH-S-4GB=
N20-BKVM=
UCS-CPU-EP-PNP=
UCS-CPU-GREASE2=
UCSX-HSCK=
Description
2.5-inch HDD Blanking Panel 1
Set of two (2) SAS/SATA Cables for C220 M3 SFF (2.5-in)
PCIe Low Profile blanking panel for UCS C-Series Server
PCIe Full Height blanking panel for UCS C-Series Server
Heat Sink for UCS C220 M3 Rack Server 1
Air Baffle Replacement Kit for C220 M3 Server 1
Replacement Lithium Battery for Server Motherboard (CR2032) 1
Battery Back-Up for 9266 2
LSI CacheVault Power Module 9266CV, 9265CV and 9285CV-8e 3
Power supply blanking panel/filler for C-Series Servers
Reversible Cable Management Arm for C220 rack servers
Rail Kit for C220 rack servers
Inner rail spare for C220 4
16GB SD Card for C220 Servers 5
Blank SD Card for UCS servers 6
4GB SLC Flash USB Drive (shorter) for all servers except C260
KVM local IO cable for UCS servers console port 7
Pick n place CPU tool set (for Intel E5 EP Socket R) 8
C220 and C240 CPU thermal grease syringe - needed for heatsink seal 8
UCS Processor Heat Sink Cleaning Kit (when replacing a CPU) 8
Notes . . .
1. This part is included/configured with your UCS server (in some cases, as determined by the configuration of your server).
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) 59
SUPPLEMENTAL MATERIAL
2. If your server contains an LSI MegaRAID SAS 9266-8i RAID controller card with battery backup
(UCS-RAID-9266), the card contains a battery backup unit (UCS-RAID-BBU), which can be replaced. If your server contains an LSI MegaRAID SAS 9266-8i RAID controller card without a battery backup unit
(UCS-RAID-9266NB), the card does not contain a battery backup unit (UCS-RAID-BBU); however, you can retrofit the card with a battery backup if desired. Note that you cannot retrofit a UCS-RAID-9266NB or
UCS-RAID-9266 RAID card with an LSI Cachevault Power Module (also known as a Supercap).
3. You can order a replacement only for the RAID cards listed. You cannot retrofit a UCS-RAID-9266NB or
UCS-RAID-9266 RAID card with an LSI Cachevault Power Module (also known as a Supercap)
4. The server is shipped with the inner rail attached to the chassis.
5. This SD card is preloaded with an image specific to the C220 server.
6. This SD card is blank. The required image for the C220 server can be downloaded to the card.
7. This part is included/configured with the server chassis.
8. This part is included with the purchase of an optional or spare CPU processor kit.
Drive Blanking Panels
A drive blanking panel (N20-BBLKD=) must be installed if you remove a disk drive from a UCS server. These panels are required to maintain system temperatures at safe operating levels, and to keep dust away from system components.
Adding an Additional CPU (with CPU heat sink)
All Cisco UCS two CPU socket-capable servers can be upgraded from having one to having two CPUs configured. You will need to order and install a heat sink when adding any additional CPU to a server.
Instructions for installing the new CPU and heat sink can be found at the following link: http://www.cisco.com/en/US/docs/unified_computing/ucs/c/hw/C220/install/replace.html#wp1233864
Motherboard Lithium Battery
You can order a replacement motherboard battery. Installation instructions are found at this link: http://www.cisco.com/en/US/docs/unified_computing/ucs/c/hw/C220/install/replace.html#wp1235772
CPU Removal and Installation (“pick n place”) Tool Set
The Pick n Place tool set includes two tools:
■ Pick and pull cap tool - used to pull off the plastic protective cap covering an empty CPU socket and to remove or lift a CPU processor without touching it
■ Pick and place tool - used to install a CPU in its socket without damage. Must be used each time a
CPU is installed in a UCS “M3” server.
Instructions for using this tool set are found at the following link: http://www.cisco.com/en/US/docs/unified_computing/ucs/c/hw/C220/install/replace.html#wp1233864
60
NOTE: When you purchase a spare CPU, the Pick n Place Toolkit is included.
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
SUPPLEMENTAL MATERIAL
Thermal Grease (with syringe applicator) for CPU to Heatsink Seal
Thermal grease must be applied to the top of the CPU where it comes in contact with the heat sink.
Instructions for applying thermal grease are found at: http://www.cisco.com/en/US/docs/unified_computing/ucs/c/hw/C220/install/replace.html#wp1233864
CAUTION: Use only the thermal grease specified for this server
(UCS-CPU-GREASE2=). Thermal grease for other systems may have different thermal conductivity properties and may cause overheating if used in the C220 M3 server. DO NOT use thermal grease available for purchase at any commercial electronics store. If these instructions are not followed, the CPU may overheat and be destroyed.
NOTE: When you purchase a spare CPU, the thermal grease with syringe applicator is included.
Air Baffle Replacement Kit
Air baffles are designed to direct airflow through the server to maintain server temperature at a safe operating level. These baffles must always remain installed during server operation. The Air Baffle
Replacement Kit includes the air baffles needed for one UCS C220 M3 server.
CPU Heat Sink Cleaning Kit
The cleaning kit is used to remove the existing thermal compound from the bottom of the heat sink during a CPU replacement process. Instructions for cleaning are found at the following link: http://www.cisco.com/en/US/docs/unified_computing/ucs/c/hw/C220/install/replace.html#wp1233864
NOTE: When you purchase a spare CPU, the CPU cleaning kit is included.
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) 61
SUPPLEMENTAL MATERIAL
RACKS
The Cisco R42610 rack (see
Figure 9 ) is certified for Cisco UCS installation at customer sites and is suitable
for the following equipment:
■
■
Cisco UCS B-Series servers and fabric interconnects
Cisco UCS C-Series and select Nexus switches
The rack is compatible with hardware designed for EIA-standard 19-inch racks. Rack specifications are
Table 35 Cisco R42610 Rack Specifications
Parameter
Dimensions (H x W x D)
Dimensions (H x W x D) with packaging
Distance from front mounting rail to rear mounting rail
Weight
Weight with packaging
Side panels included
Equipment mounting capacity
Static load capacity
Standard Rack
78.74 x 24 x 43.38 in.
(2000 x 610 x 1102 mm)
89 x 33 x 47 in.
(2261 x 838 x 1194 mm)
29.2 in (741 mm)
299.83 lb (136 kg)
354 lb
(161 kg)
Yes
42RU
Dynamic load capacity
2100 lb
(954 kg)
Not applicable
Expansion Rack
78.74 x 23.58 x 43.38 in.
(2000 x 599 x 1102 mm)
89 x 33 x 47 in.
(2261 x 838 x 1194 mm)
29.2 in (741 mm)
231. 49 lb (105 kg)
284 lb
(129 kg)
No
42RU
2100 lb
(954 kg)
Not applicable
NOTE: The AC input connector is an IEC 320 C-14 15 A/250 VAC power inlet.
62 Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
Figure 9 Cisco R42610 Rack
SUPPLEMENTAL MATERIAL
Front view - door closed Front view - door open Front view - door removed
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) 63
SUPPLEMENTAL MATERIAL
PDUs
Cisco RP Series Power Distribution Units (PDUs) offer power distribution with branch circuit protection.
Cisco RP Series PDU models distribute power to up to 24 outlets. The architecture organizes power distribution, simplifies cable management, and enables you to move, add, and change rack equipment without an electrician.
With a Cisco RP Series PDU in the rack, you can replace up to two dozen input power cords with just one.
The fixed input cord connects to the power source from overhead or under-floor distribution. Your IT equipment is then powered by PDU outlets in the rack using short, easy-to-manage power cords.
The C-series severs accept the zero-rack-unit (0RU) PDU. See Figure 10 ).
Figure 10 Zero Rack Unit PDU (PID = RP208-30-2P-U-2)
1
2
Breakers
Ground connection
3
4
C19 plugs
C13 plugs
Cisco RP Series PDU models provide two 20-ampere (A) circuit breakers for groups of receptacles. The effects of a tripped circuit are limited to a receptacle group. Simply press a button to reset that circuit.
64 Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
SUPPLEMENTAL MATERIAL
KVM CABLE
The KVM cable provides a connection into the server, providing a DB9 serial connector, a VGA connector for a monitor, and dual USB ports for a keyboard and mouse. With this cable, you can create a direct connection to the operating system and the BIOS running on the server.
The KVM cable ordering information is listed in
.
Table 36 KVM Cable
Product ID (PID)
N20-BKVM
PID Description
KVM cable for B-Series Blade Server console port
Figure 11 KVM Cable
1
2
Connector (to server front panel)
DB-9 serial connector
3
4
VGA connector (for a monitor)
Two-port USB connector (for a mouse and keyboard)
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) 65
SUPPLEMENTAL MATERIAL
Motherboard USB and SD Ports, and RAID Card Backup Location
The C220 M3 SFF motherboard has a general-purpose USB socket, and two SD sockets as shown in
The mounting location for the RAID SuperCap data cache power backup module is also shown.
Figure 12 Motherboard USB and SD Ports and RAID Card Super Capacitor Location
4
SAS1
SAS2
PCIe1
CPU1
2
CPU2
PCIe2
PSU2
1
3
PSU1
1
2
SD1 socket
SD2 socket
3
4
USB connector
SuperCap module mounting location
66 Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
TECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS
Dimensions and Weight
Table 37 UCS C220 M3 Dimensions and Weight
Parameter
Height
Width
Depth
Front Clearance
Side Clearance
Rear Clearance
Weight
Maximum (8 HDDs, 2 CPUs, 16 DIMMs, 2 power supplies)
Minimum (1 HDD, 1 CPU, 1 DIMM, 1 power supply)
Bare (0 HDD, 0 CPU, 0 DIMM, 1 power supply)
Value
1.7 in. (4.32 cm)
16.92 in.(43.0 cm)
28.5 in. (72.4cm)
3 in. (76 mm)
1 in. (25 mm)
6 in. (152 mm)
35.6 lbs (16.2 kg)
26.8 lbs (12.1 kg)
22 lbs (10 kg)
Power Specifications
Table 38 UCS C220 M3 SFF 450 W Power Supply Specifications
Description
AC input voltage
AC input frequency
Maximum AC input current
Maximum AC inrush current
Maximum output power for each power supply
Power supply output voltage
Specification
90 to 264 VAC self-ranging,
100 to 120 VAC nominal
200 to 240 VAC nominal
Range: 47 to 63 Hz (single phase, 50 to 60 Hz nominal)
7.6 A peak at 100 VAC
3.65 A peak at 208 VAC
11 A
450 W
Main power: 12 VDC
Standby power: 12 VDC
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) 67
TECHNICAL SPECIFICATIONS
Table 38 UCS C220 M3 SFF 450 W Power Supply Specifications
Description
Power supply efficiency
Specification
CSCI Platinum
NOTE: AC input connector is an IEC 320 C-14 15A/250VAC power inlet.
Table 39 UCS C220 M3 SFF 650 W Power Supply Specifications
Description
AC input voltage
AC input frequency
Maximum AC input current
Maximum AC inrush current
Maximum output power for the power supply
Power supply output voltage
Specification
90 to 264 VAC self-ranging,
100 to 120 VAC nominal
200 to 240 VAC nominal
Range: 47 to 63 Hz (single phase, 50 to 60 Hz nominal)
7.6 A peak at 100 VAC
3.65 A peak at 208 VAC
11 A
650 W
Power supply efficiency
Main power: 12 VDC
Standby power: 12 VDC
CSCI Platinum
NOTE: AC input connector is an IEC 320 C-14 15A/250VAC power inlet.
For configuration-specific power specifications, use the Cisco UCS Power Calculator at this URL: https://express.salire.com/Go/Cisco/Cisco-UCS-Power-Calculator.aspx
68 Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
TECHNICAL SPECIFICATIONS
Environmental Specifications
The power specifications for the C220 M3 server are listed in Table 40 .
Table 40 UCS C220 M3 Environmental Specifications
Parameter
Temperature operating
Minimum
41 to 104° F (5 to 40° C) derate the maximum temperature by 1°C per every 305m of altitude above sea level
–40 to 149°F (–40 to 65°C)
10 to 90%
Temperature nonoperating
Humidity (RH) nonoperating, non-condensing
Altitude operating
Altitude nonoperating
Sound Power level, Measure
A-weighted per ISO7779 LWAd (Bels)
Operation at 73°F (23°C)
Sound Pressure level, Measure
A-weighted per ISO7779 LpAm (dBA)
Operation at 73°F (23°C)
0 to 3,000 m (0 to 10,000 ft.)
0 to 12,192 m (0 to 40,000 ft.)
5.4
37
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) 69
TECHNICAL SPECIFICATIONS
Compliance Requirements
The regulatory compliance requirements for C-Series servers are listed in
.
Table 41 UCS C-Series Regulatory Compliance Requirements
Parameter
Regulatory Compliance
Safety
EMC - Emissions
EMC - Immunity
Description
Products should comply with CE Markings per directives
2004/108/EC and 2006/95/EC
UL 60950-1 Second Edition
CAN/CSA-C22.2 No. 60950-1 Second Edition
EN 60950-1 Second Edition
IEC 60950-1 Second Edition
AS/NZS 60950-1
GB4943 2001
47CFR Part 15 (CFR 47) Class A
AS/NZS CISPR22 Class A
CISPR22 Class A
EN55022 Class A
ICES003 Class A
VCCI Class A
EN61000-3-2
EN61000-3-3
KN22 Class A
CNS13438 Class A
EN55024
CISPR24
EN300386
KN24
70 Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
Λήψη
Διαφήμιση