The Flextwist waveguide is a flexible waveguide that is used to connect the MPT-HC V2/MPT-XP output flange to the external antenna. It is available in a variety of lengths and frequencies to meet your specific needs. The MPT-HC V2 and MPT-XP transceivers are designed for high-performance wireless communications. They are equipped with advanced features such as Adaptive Modulation and Coding (AMC), diversity reception, and automatic power control.
Advertisement
Advertisement
Hardware installation
Figure 322: XPIC cable interconnection
Note: The extra length of the RPS and XPIC cables must be bound by using tie-raps, either on the pole or on the other cables coming from the ODUs.
Installing the “Flextwist” waveguide (non integrated antenna)
Concerning the interface between the MPT-HC V2/MPT-XP output flange and the suggested
antenna flange, Table 88 details for each product the standard wave guide to be used and the
suggested flange for the external antenna.
Note: the use of 600 mm flex twist is not suggested for antennas bigger than 3ft (90 cm diameter), due to mechanical reasons. The suggested way to make the RF connection is to use the elliptical wave guide fitted with flanged connectors.
374 MPR-e
Installation
18
23
26
38
11
13
15
Range
(GHz)
6
7-8
Table 88: MPT-HC V2/MPT-XP/9558HC Output flanges with external antenna
MPT-HC
V2/
MPT-XP/
9558HC
Output
Flange
A
UBR70
UDR84 or
UBR84
UBR100
UBR120
UBR140
UBR220
FLEXTWIST
C.E.I.
R70
R84
R84
R100
R120
R140
R220
E.I.A.
WR137
WR112
WR112
WR90
WR75
WR62
WR42
B
PDR70
PDR84
PBR84
PBR100
PBR120
PBR140
PBR220
C
UDR70
UBR84
UBR84
UBR100
UBR120
UBR140
UBR220
Suggested
Antenna
Flange
D
PDR70
PBR84
PBR84
PBR100
PBR120
PBR140
PBR220
UBR320 R320 WR28 PBR320 UBR320 PBR320
The long twistable flexible waveguide is supplied complete with gaskets and fasteners. At one end, it has a smooth square or rectangular flange (to be mounted on the antenna) and at the other end, a grooved square flange designed to accommodate an O–ring seal (mounted at the MPT-HC V2/MPT-XP/9558HC end).
MPR-e 375
Hardware installation
Table 89: Flextwist waveguide
FLEXIBLE TWISTABLE WAVEGUIDE KIT
Alcatel-Lucent
Part number
Waveguide
Lengt h mm.
Freq
Ban d
GHz
Flanges Stainle ss steel socket cap screws
Stainle ss steel socket cap screws
“Ondu flex” spring y crinkle washe rs
Stainle ss Z. flat washer s
HM.
Hex nuts
6-7-8GHz
1AF02951ABAA WR137 1000 6
3CC08010ABAB WR112 1000 7.05
-10
PD
R70
PB
R84
UD
R70
UB
R84
)
8
(M4x25
)
8
(M4x25
)
)
8
(M4x12
8
(M4x12
8
(B4)
8
(B4)
8 (Z4)
)
)
8
(HM4
8 (Z4) 8
(HM4
11-38GHz
1AF02957ABAA WR90 1000 11 8
(B4)
3CC05751ACAA
3CC05750ACAA
3CC05749ACAA
3DB00682AAA
A
WR75
WR62
WR42
WR28
600
600
600
600
10-
15.0
12.4
-18
18-
26.5
26.5
-40
PB
R14
0
PB
R22
0
PB
R10
0
PB
R12
0
PB
R32
0
UB
R14
0
UB
R22
0
UB
R10
0
UB
R12
0
UB
R32
0
)
8
(M4x20
8
)
(M4x20
)
8
(M4x20
8
)
(M3x20
)
8
(M3x20
)
8
(M4x12
8
)
(M4x12
)
8
(M4x12
8
)
(M3x12
)
8
(M3x12
8
(B4)
8
(B4)
8
(B3)
8
(B3)
12 (Z4) 12
(HM4
)
12 (Z4) 12
)
(HM4
8 (Z4) 8
(HM4
)
8 (Z3) 8
)
(HM3
8 (Z3) 8
(HM3
)
1.
If the FLEX–TWIST is not provided by Alcatel-Lucent, the user must carefully choose the type of the connection guide in order to limit as much as possible galvanic couples between ANTENNA/flex–twist and flex–twist/MPT-HC V2/MPT-XP/9558HC contact surfaces that can induce rust. For this purpose, please note that the surfaces are:
→ chromium-plated at MPT-HC V2/MPT-XP/9558HC output flange side
376 MPR-e
Installation
→ tin-plated at flex-twist’s flange side
MPT-HC V2/MPT-XP/9558HC system grounding
Each MPT-HC V2/MPT-XP/9558HC transceiver must be individually grounded.
Note: Neither the RF coupler, nor the antennas, integrated or not integrated, should be grounded.
The following items are necessary for the individual grounding of each MPT-HC V2/
MPT-XP/9558HC transceiver:
• one MPT-HC V2/MPT-XP/9558HC Grounding cable 16 mm2 (P/N
1AC001060084).
This 16 mm2 cable must be cut on site and connected to the terminal provided on the
MPT-HC V2/MPT-XP/9558HC transceiver, and, on the other side, to the nearest grounding plate;
This example figure shows the grounding connector position.
Figure 323: Grounding connector example
MPR-e
Connect all grounding cables to the nearest grounding plate, as shown in this example:
377
Hardware installation
Figure 324: Grounding cables connected to grounding plate
Cable grounding
The Power Supply cable and the Ethernet electrical cable must be grounded by using the dedicated Grounding kits.
For ground kit installation instructions refer to the guide provided with each kit.
For tower/mast installations the cables must be grounded at:
• The point where it comes on to the tower from the MPT-HC V2/MPT-XP/9558HC
• The point where it leaves the tower to go to the equipment building
• Maximum distance between the grounding kits: 50 m
• A point just prior to building entry
Figure 325 shows typical tower locations for cable grounding.
Note: All the cables (coax cable, Cat5e cable, fiber cable) must be fixed to the tower with the relevant ties.
At non-standard installations, such as building tops or the sides of buildings, follow the same general guidelines but where proper grounding points are not provided these must first be installed.
378 MPR-e
Figure 325: Locations for cable grounds
Installation
Type N connectors and grounding kits waterproofing on the IDU/
ODU cables
Warning: To make sure of the continuity and avoid short circuit, all cables / connectors connections such as RJ45, Coaxial, Ethernet, or Optical Fiber made in the field have to be verified and checked with Cable tester. The waterproofness must be also checked.
For installation on the type N to RJ-45 adapters and grounding kits, refer to the installation notice provided with the connector and the grounding kit.
IMPORTANT:
MPR-e 379
Hardware installation
To prevent potential problems Alcatel-Lucent recommends that particular attention be paid to waterproofing the connection.
To ensure that the connection will hold in bad weather, remember the waterproofing at the end of the operation with the Self auto-amalgamating + UV protection vinyl tape by necklaces Colson / Tie raps at every extremity.
For the assembly between the cable, grounding kit and ODU outdoors, Alcatel-Lucent recommends that you waterproof the cables. Use the Self auto-amalgamating (several turns) to assure the waterproofing. Then cover the set with UV protection vinyl tape to cover the self-amalgamating and end with a necklaces Colson / Tie raps.
Example of N connector waterproofing
Figure 326: N connector waterproofing example
Example of grounding kit & waterproofing
The Power Supply cable and Ethernet electrical cable kits include detailed assembling instructions.
See
Figure 327 and Figure 328 to install the kit on the coaxial cable and complete the
waterproofing.
380 MPR-e
Figure 327: Example of realization
Installation
Figure 328: Detail of the waterproofing of the kit
MPR-E: MPT-MC installation
The MPT-MC installation section is divided in:
•
•
•
How to change polarization in the MPT-MC
MPR-e 381
Hardware installation
•
Types of pole mounting installation kits
•
•
1+0 MPT-MC installation (integrated antenna) - all frequencies
•
1+0 MPT-MC installation (non integrated antenna) - all frequencies
•
To terminate the Ethernet cable (MPT-MC side) and to pull it up from indoor to
•
Installing the “Flextwist” waveguide (not integrated antenna cases)
•
•
•
Grounding kits waterproofing on the IDU/ODU cables
Types of MPT-MC
The MPT-MC consists of one or two cabinets including the Ethernet interface + modem + RF transceiver + branching of a channel.
Two mechanical solutions are adopted:
• with embedded diplexer for cost optimisation, shown in
branching (diplexer) is internal to the MPT-MC cabinet; this type of MPT-MC is identified by one Logistical Item only;
• with external diplexer: due to a high number of shifters, the diplexer is external for the flexibility of the shifter customization, shown in
composed by two independent units: the branching assembly (containing the diplexer) and the RF transceiver assembly (containing the RF section); each of this type of MPT-MC is identified by two Logistical Items, one for the branching assembly and another for the RF transceiver assembly. To read the branching assembly identification label it is necessary to separate the branching assembly from the RF transceiver assembly.
382 MPR-e
Figure 329: Views of MPT-MC with embedded diplexer
Installation
MPR-e 383
Hardware installation
Figure 330: Views of MPT-MC with external diplexer
MPT-MC operative information
This section gives operative information, for installation regarding:
•
MPT-MC with embedded or external diplexer
• MPT-MC with external diplexer (additional information)
Operative information on MPT-MC with embedded or external diplexer
General, views and access points
(for MPT-MC with embedded diplexer) and Figure 332
(for MPT-MC with external diplexer) show MPT-MC views and access points.
384 MPR-e
Installation
The external interfaces are listed in Table 90 , with the corresponding connector.
Ref. in
and
(1)
(2)
Interface
Table 90: MPT-MC external interfaces
Connector
RF interface for connection of antenna or coupler
Ethernet electrical cable waveguide
R2CT
Further information
FREQUENCY GHz ->
Waveguide type ->
6 7
Table 91: RF interface
8 11
WR137 WR112 WR112 WR75
13-15
WR62
Figure 331: Views of MPT-MC with embedded diplexer
18-26
WR42
38
WR28
MPR-e 385
Hardware installation
Table 92: References for views of MPT-MC with embedded diplexer
(A) Locking hooks (4) to fix/unfix MPT-MC assembly to antenna or coupler
(1)
RF interface for connection of antenna or coupler. Remove the plastic cover.
WARNING: A waterproofness tape is glued on the waveguide of the MPT-MC. It must never be removed.
Figure 332: Views of MPT-MC with external diplexer
386
Table 93: References for views of MPT-MC with external diplexer
(A) 4 locking hooks to fix/unfix branching assembly (diplexer) to transceiver
(B) 4 locking hooks to fix/unfix branching assembly (diplexer) to antenna or coupler
(1)
RF interface for connection of antenna or coupler. Remove the plastic cover.
WARNING: A waterproofness tape is glued on the waveguide of the MPT-MC. It must never be removed.
MPR-e
Installation
Additional operative information on MPT-MC with external diplexer
MPT-MC composition
As shown in
Figure 333 , the MPT-MC assembly is made up of two boxes, one for diplexer
system (branching) and the other for the all other active functions (transceiver) connected together to form the MPT-MC.
An O-RING present in the transceiver box guarantees the MPT-MC assembly waterproofness.
Note: This is a conductive O-RING and must be left dry. Do not wet it with silicon grease
(silicon grease must be used only on O-ring between MPT-MC and antenna).
Figure 333: Composition of MPT-MC with external diplexer
MPR-e
Warning: A waterproofness tape is glued on the waveguide of the MPT-MC. It must never be removed.
387
Hardware installation
Warning: This gasket must never be removed.
The transceiver box performs all the functions, but does not include the diplexer system.
The branching box provides the interface between the pole mounting/antenna and the transceiver.
The favorite solution foresees the possibility to change in field a spare part transceiver without disconnecting the branching box from the pole mounting/antenna. The transceiver and branching boxes fixing and unfixing are obtained through the four levers.
Transceiver and branching boxes coupling
Figure 334 below shows the transceiver and branching boxes coupling surfaces:
• (A) branching box label informative content described in
• (B) (High Freq) and (C) (Low Freq) RF interfaces on branching box
• (D) (TX) and (E) (RX) RF interfaces on transceiver box
The transceiver and branching boxes can be coupled in two alternative ways (180°-rotated with respect to each other):
• branching box (B) (High Freq) coupled to transceiver box’s (D) (TX)
In this case, the TX part of the transceiver uses the high frequency range of the Shifter set by the Craft Terminal (see
Figure 336 ); the RX part of the transceiver uses the
corresponding LOW frequency range;
• branching box (C) (Low Freq) coupled to transceiver box’s (D) (TX)
In this case, the TX part of the transceiver uses the LOW frequency range of the
Shifter set by the Craft Terminal (see
Figure 336 ); the RX part of the transceiver uses
the corresponding high frequency range.
388 MPR-e
Installation
Figure 334: MPT-MC transceiver and external diplexer coupling surfaces
(D)
(A) (B)
(C)
Hole Mistake-proofing
(E)
Note: There is only one possible way to couple the branching box and the transceiver box: there is a mistake-proofing put by the factory on the transceiver box, whose position depends on the type of transceiver (low or high band, as shown in
that the association with the branching box is always the right one.
Labels affixed on the MPT-MC
•
The label depicted in Figure 335
is affixed externally to all types of MPT-MC transceiver boxes;
• Only for MPT-MC with external diplexers, an additional label, depicted in
Figure 336 , is placed on the branching assembly.
MPR-e 389
Hardware installation
Figure 335: Label affixed on the MPT-MC transceiver box
Table 94: References for label affixed on the MPT-MC transceiver box
SYMBOL OR WRITING MEANING
9500-MPR Equipment Acronym & Alcatel-Lucent Logo
!
CE European Community logo
Not harmonized frequency logo
2002/96/EC WEEE (Waste Electrical and
Electronic Equipment) Logo
390
WEEE Symbol 21828
-28 V / -58 V 1,6 A / 0,8 A
Logistical Item (shown numbers as examples)
A
Serial n° (shown numbers as examples)
Power supply range and current range
Logistical Item for Customer
Logistical Item for Customer, bar code 128
Factory Serial number
B Factory Serial number bar code 128
TX Frequency MHz (shown numbers as examples) Working frequency range
MPR-e
Installation
Table 94: References for label affixed on the MPT-MC transceiver box
Shifter MHz (shown numbers as examples) Shifter
TX Sub-band (shown numbers as examples)
Initial SW/ICS (shown numbers as examples)
TX Sub-band
P/N and ICS of the software loaded in factory
PN/ICS (shown numbers as examples)
C
Factory P/N + ICS
Factory P/N + ICS bar code 128
Figure 336: Label affixed inside the MPT-MC branching box
Table 95: References for label affixed inside the MPT-MC branching box
SYMBOL OR WRITING MEANING
ALU LOGO
9500 MPR
C E
Alcatel-Lucent Logo
Equipment Acronym
European Community logo
!
0682
WEEE LOGO
P/N / ICS 3DBXXXXXAAAA 01
CETECOM Number
Not Harmonized Frequency Logo
WEEE Logo
Part Number + ICS
MPR-e 391
Hardware installation
Table 95: References for label affixed inside the MPT-MC branching box
LOGISTICAL ITEM 3DBXXXXXAAXX Logistical Item
S.N. GA081528595
A
Serial number
P/N + ICS Bar Code Alpha 128
B
C
Shifter MHz
TX
F min MHz
F max MHz
Logistical Item Bar Code Alpha 128
Serial Number Bar Code Alpha 128
Frequency Denomination
How to change polarization in the MPT-MC
6 and 11-38 GHz MPT-MC with embedded diplexer
Note: The polarization must be changed to match the antenna polarization and the coupler nose waveguide.
Warning: A waterproofness tape is glued on the waveguide of the MPT-MC. It must never be removed.
To change the polarization:
1. Remove the plastic cover from the MPT-MC.
392 MPR-e
MPR-e
Figure 337: Remove the plastic cover from the MPT-MC
Installation
2. Unscrew the screws to change the polarization if required. Vertical polarization is the default. Use an Allen wrench to change the polarization.
Figure 338: Vertical Polarization
393
Hardware installation
Figure 339: Horizontal polarization
7-8 GHz MPT-MC with external diplexer
These MPT-MC have fixed polarization (vertical polarization). To change the polarization, it is necessary to change the antenna polarization and to install the MPT-MC 90° rotated.The following figures provide examples.
Figure 340: Example of vertical polarization (left offset)
Figure 341: Example of vertical polarization (right offset)
394 MPR-e
Figure 342: Example of horizontal polarization (left offset)
Installation
Figure 343: Example of horizontal polarization (right offset)
Types of pole mounting installation kits
See
Types of Pole mounting installation kits .
Types of nose adapters
See
1+0 MPT-MC installation (integrated antenna) - all frequencies
To perform the installation:
1. Check/Set the coupling between the transceiver and branching boxes (only for MPT-
MC with external diplexer).
2. Install the Antenna and Pole Mounting.
This pole mounting is delivered as “pole mounting”, “antenna”, and frequencyspecific “nose adapter” already assembled. The integrated antenna is mounted on the pole front.
MPR-e 395
Hardware installation
Antenna and pole mounting must be installed in accordance with the manufacturer’s instructions.
3. Check or change the polarization on the Antenna nose.
To change the polarization, follow the instructions supplied with each antenna.
Note: The antennas are normally supplied with vertical polarization.
Figure 344: Example of antenna polarization change (“1+0” MPT-MC integrated antenna)
396
4. Install the MPT-MC on the Antenna nose adapter.
MPR-e
MPR-e
Installation
Note: Silicone grease must be put on the nose adapter O-ring when indicated in the manufacturer’s installation instructions. If grease for O-ring is not mentioned, it must be avoided.
Figure 345: Putting silicone grease on O-ring before MPT-MC insertion
5. Grasp the MPT-MC module by the handle.
6. Open the four looking hooks (1) arranged on the four walls of the MPT-MC unit.
7. For 7-8 GHz MPT-MC only rotate the MPT-MC depending on the horizontal or vertical polarization, and slide it on the nose adapter.
8. Secure the MPT-MC module through the four hooks (1) on the relative brackets (2).
Figure 346: MPT-MC 1+0 installation for integrated antenna (internal diplexer)
397
Hardware installation
Note: For 6 GHz and 11-38 GHz MPT-MC remember to set first the correct polarization.
Figure 347: MPT-MC 1+0 installation for integrated antenna (7-8 GHz: external diplexer: vertical polarization)
398 MPR-e
Installation
Figure 348: MPT-MC 1+0 installation for integrated antenna (7-8 GHz: external diplexer: horizontal polarization)
Note: The MPT-MC/antenna assembly requires no additional seal on the SHF flanges; the two ends are smooth. The O-ring seal around the male “nose” provides sealing.
9. Ground the MPT-MC system.
10. Pre-point the antenna.
11. Affix the EMF stickers.
1+0 MPT-MC installation (non integrated antenna) - all frequencies
To perform the installation:
1. Check/Set the coupling between the transceiver and branching boxes (only for MPT-
MC with external diplexer).
2. Install the Nose Adapter on the “Pole Mounting for Remote ODU”.
3. Install the “Pole Mounting for Remote ODU”.
Pole mounting must be installed in accordance with the manufacturer’s instructions.
In case of missing instructions, fix the U-bolts with 34 N x m tightening torque.
MPR-e 399
Hardware installation
Note: The pole mounting can be installed on the Right or Left hand side of the pole depending on the azimuth and on the configuration of the tower.
Figure 349: "Pole Mounting for Remote ODU" installation
4. Install the MPT-MC.
Note: Silicone grease must be put on the nose adapter O-ring when indicated in the manufacturer’s installation instructions. If grease for O-ring is not mentioned, it must be avoided.
Figure 350: Putting silicone grease on O-ring before MPT-MC insertion
400
5. Grasp the MPT-MC module by the handle. Open the four looking hooks arranged on the four walls of the MPT-MC unit.
6. Position the Pole mounting support on the pole side as shown in the plant documentation.
MPR-e
Installation
7. Position the MPT-MC and slide it on the nose adapter.
8. Secure the MPT-MC module through the four hooks onto the relative brackets.
Figure 351: MPT-MC 1+0 installation for not integrated antenna (with pole mounting P/
N 3DB10137AAXX)
9. Install the external Antenna with its own Pole Mounting.
The installation of the antenna and of its own pole mounting, as well as the antenna polarization check/change, must be done in accordance with the manufacturer’s instructions.
10. Connect the antenna side (flange) of the Pole Mounting’s nose adapter to the external
11. Ground the MPT-MC system.
12. Pre-point the antenna.
13. Affix the EMF stickers.
To terminate the Ethernet cable (MPT-MC side) and to pull it up from indoor to MPT-MC
Only one cable interconnects the MPT-MC with the Power Injector. See
.
Installing the “Flextwist” waveguide (not integrated antenna cases)
See
Installing the “Flextwist” waveguide (non integrated antenna) .
MPR-e 401
Hardware installation
MPT-MC system grounding
See
MPT-HC V2/MPT-XP/9558HC system grounding
.
Cable grounding
See
Grounding kits waterproofing on the IDU/ODU cables
See
Type N connectors and grounding kits waterproofing on the IDU/ODU cables .
Power injector
The following considerations apply when using a power injector:
• Elevated Operating Ambient - If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than room ambient temperature. Therefore, consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature
(Tma) specified by the manufacturer.
• Reduced Air Flow - Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised.
• Mechanical Loading - Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading.
• Circuit Overloading - Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of the circuits might have on over current protection and supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern.
• Reliable Earthing - Reliable earthing of rack-mounted equipment should be maintained.
• Particular attention should be given to supply connections other than direct connections to the branch circuit (e.g. use of power strips).
402 MPR-e
Installation
Power injector box
The installation in 19” rack is shown in
Note: Disconnect all power supply cords before servicing.
The Power Injector box must be first installed on the bracket (3DB77008ACXX) by using the screws provided with the bracket, and then the assembly must be installed on the rack.
Figure 352: Power injector box + bracket 3DB77008ACXX
For the installation in 21” rack the 21” Adapter kit (3CC50065AAAA) must be added to each
19” installation configuration.
Power injector box grounding
The assembly must be grounded by using the ground screw present on the bracket, as shown
.
The section cable (wire) is 6 mm² (9AWG) (Yellow/Green).
Figure 353: Grounding
MPR-e 403
Hardware installation
Power supply cable
Figure 354: Power supply connector
Note: The power source "office power" is isolated from AC power main feeds.
A 2-wire power cable (2x1 mm2 - AWG17) is supplied (1AC007800068).
Note: Power cable gauge smaller than 2x1 mm2 (AWG 17) is not allowed for proper operation of the Power Injector box.
The blue wire must be connected to -48 Vdc (live); the black wire to + (Return).
The cable must be screwed to the Power Injector box and to the battery.
Note: The Power supply must be connected to a fuse or a breaker on a customer power distribution box. The recommended value is 3 Amps for one ODU and 6 Amps for two
ODUs.
Power injector card
The Power Injector card is installed inside the 7705 SAR.
Figure 355: Power Injector card
404 MPR-e
Installation
Grounding
The subrack must be grounded using the ground screw present on the front panel of the bracket on the right side.
The section cable (wire) to use must be a 6 mm² (9AWG) (Yellow/Green).
The subrack-mounting item adds a good electrical connection to rack ground.
MPT extended power unit
With the MPT Extended Power Unit, the interconnection with the MPT-XP can be made with electrical Ethernet cable for cable run lengths less than 100 m by using the PFoE solution
(Ethernet traffic and Power Supply on the same cable). The MPT Extended Power Unit combines Power with the data to implement the PFoE solution.
One cable, interconnects the MPT Extended Power Unit with the MPT-XP (the PFoE cable to be connected to the DC+ODU Data connector of the MPT Extended Power Unit and
Ethernet cable to be connected to the DC+Data connector of the MPT-XP). A second cable interconnects the MPT Extended Power Unit IDU Data connector with the electrical Ethernet connector.
To prepare and to terminate the “Ethernet data + Power Supply” cable (to be connected to
MPT Extended Power Unit and to the DC+Data connector of the MPT-XP) follow the
instructions given in To terminate the Ethernet cable (MPT-HC V2/MPT-MC/MPT-XP/
9558HC side) and to pull it up from Indoor to MPT-HC V2/MPT-MC/MPT-XP/9558HC .
The R2CT connector used to terminate the cable (MPT-XP side) must be provided.
When optical cable is used to transport the Ethernet traffic to the MPT-XP, the MPT
Extended Power Unit provides power to the MPT-XP using coax cable connected to the Type
N DC connector on the MPT Extended Power Unit.
Coax cable, interconnects the MPT Extended Power Unit with the MPT-XP (the coax cable to be connected to the DC connector of the MPT Extended Power Unit. An adapter cable converts coax to RJ-45 to be connected to the DC+Data connector of the MPT-XP).
To prepare and to terminate the coax Power Supply cable (to be connected to MPT Extended
Power Unit and to the DC+Data connector of the MPT-XP) follow the instructions given in
The R2CT connector used to terminate the cable (MPT-XP side) must be provided.
MPR-e 405
Hardware installation
MPR-E Indoor Installation items
This section includes:
•
Indoor accessories for MPT-HC V2/MPT-XP/9558HC
•
Accessories and cables for MPT-HC V2/MPT-XP/9558HC connections
•
MPR-E: Accessories and cables for MPT-MC connections
•
Nose Adapter for MPT-HC V2/MPT-MC, MPT-XP, and 9558HC
•
Flextwists and N cable for MPT-HC V2/MPT-MC, MPT-XP, and 9558HC
•
Indoor accessories for MPT-HC V2/MPT-XP/9558HC
3CC52159AAXX
1AB251350001
3CC50030AAAA
Table 96: Indoor accessories for MPT-HC V2/MPT-XP/9558HC
Pigtail
Low Pass Filter
Lightning Arrestor
These accessories must be used to connect the power coaxial cable of
MPT-HC V2/MPT-XP/9558HC to the battery
Accessories and cables for MPT-HC V2/MPT-XP/9558HC connections
Table 97: Accessories and cables for MPT-HC V2/MPT-XP/9558HC connections
3DB18205AAAA
3CC50074ABAA
1AB357780003
QMA (male)-N (Female) RF cable
Support kit for 4 cord N/QMA MPR IDU
QMA 90° connector for coax. cable (diam.=6.85 mm)
3CC52188AAXX
1AB074610027
1AB150990002
N-to-Ethernet pair pigtail (N female-Free wires) for the power supply cable (1 m)
RJ45 connector (boot included). To be terminated on the 1 m Adapter cord for Indoor connection or Outdoor connection.
R2CT connector. To be terminated on the 1 m Adapter cord for Outdoor connection.
406 MPR-e
Installation
Table 97: Accessories and cables for MPT-HC V2/MPT-XP/9558HC connections
1AD160490001 Tool for HIROSE RJ45 IDU-ODU cable assembling
1AC016760006
1AD040130004
IDU-ODU Cat5e Ethernet cable (cable to be used for PFoE, with RJ45 and R2CT connectors)
Grounding kit for Cat5e cable
Outdoor Grounding cable 16 mm2 1AC001060084
1AC001100022
1AB095530023
1AB128500002
1AC041350001
1AB095530036
1AD040130004
Coax cable 50 ohm (diam.=10.3 mm) for L>200 m
N Conn. male straight 50 ohm for coax. cable (diam.=10.3 mm)
Grounding kit for coax. cable (diam.=10.3 mm)
Coax. cable 50 ohm (diam.=6.85 mm) for L<200 m
N Conn. male straight 50 ohm for coax. cable (diam.=6.85 mm)
Grounding kit for coax. cable (diam.=6.85 mm)
3CC52170ANXX or
3CC52170BN
3CC52170AMXX or
3CC52170BM
3CC52170AAXX or
3CC52170BA
3CC52170ABXX or
3CC52170BB
3CC52170ACXX or
3CC52170BC
3CC52170ADXX or
3CC52170BD
3CC52170AEXX or
3CC52170BE
LC/Q-XCO to LC Fiber cord (L = 25 m for MPR-e IDU-ODU connection)
LC/Q-XCO to LC Fiber cord (L = 50 m for MPR-e IDU-ODU connection)
LC/Q-XCO to LC Fiber cord (L = 80 m for MPR-e IDU-ODU connection)
LC/Q-XCO to LC Fiber cord (L = 100 m for MPR-e IDU-ODU connection)
LC/Q-XCO to LC Fiber cord (L = 120 m for MPR-e IDU-ODU connection)
LC/Q-XCO to LC Fiber cord (L = 140 m for MPR-e IDU-ODU connection)
LC/Q-XCO to LC Fiber cord (L = 160 m for MPR-e IDU-ODU connection)
MPR-e 407
Hardware installation
3CC52170BF
Table 97: Accessories and cables for MPT-HC V2/MPT-XP/9558HC connections
3CC52170AFXX or
3CC52170AGXX or
3CC52170BG
3CC52170AHXX or
3CC52170BH
3CC52170AIXX or
3CC52170BY
3CC52170ALXX or
3CC52170BL
3CC50097AAXX
LC/Q-XCO to LC Fiber cord (L = 180 m for MPR-e IDU-ODU connection)
LC/Q-XCO to LC Fiber cord (L = 200 m for MPR-e IDU-ODU connection)
LC/Q-XCO to LC Fiber cord (L = 220 m for MPR-e IDU-ODU connection)
LC/Q-XCO to LC Fiber cord (L = 250 m for MPR-e IDU-ODU connection)
LC/Q-XCO to LC Fiber cord (L = 300 m for MPR-e IDU-ODU connection)
Cable overlength box (wall and pipe mounting only)
3CC52186AAXX
3CC52186ABXX
3CC52186ACXX
3CC52169AAXX or
3CC52169BA
3CC52169ABXX or
3CC52169BB
3CC52169ACXX or
3CC52169BC
3CC52189AAXX or
3CC52189BA
3CC52189ABXX or
3CC52189BB
3CC52189ACXX or
3CC52189BC
XPIC cable cat7 (L = 1 m)
XPIC cable cat7 (L = 2.5 m)
XPIC cable cat7 (L = 8 m)
RPS LC-LC optical jumper preassembled with Q-XCO (L = 1 m)
RPS LC-LC optical jumper preassembled with Q-XCO (L = 10 m for space diversity)
RPS LC-LC optical jumper preassembled with Q-XCO (L = 20 m for space diversity)
RPS Q-XCO to Q-XCO cable (L = 1 m)
RPS Q-XCO to Q-XCO cable (L = 10 m)
RPS Q-XCO to Q-XCO cable (L = 20 m)
3CC50098AAXX
3CC50099AAXX
MPR-MPT tool bag (special tools)
Standard tool bag
408 MPR-e
Installation
Table 97: Accessories and cables for MPT-HC V2/MPT-XP/9558HC connections
3CC50173AAXX
3CC50174AAXX
MPT Power Unit (includes rack mounting bracket)
MPT Extended Power Unit (includes rack mounting bracket)
MPR-E: Accessories and cables for MPT-MC connections
Table 98: MPR-E: Accessories and cables for MPT-MC connections
1AC016760006
1AB074610027
1AD160490001
1AB150990002
1AD040130004
1AC001060084
IDU-ODU Ethernet cable Cat5e shield 80% for outdoor environment
RJ45 connector (cable diam <=7mm) (boot included)
Tool for HIROSE RJ45 IDU-ODU cable assembling
Kit plug R2CT
Grounding kit for RJ45 Ethernet electrical cable
Outdoor Grounding cable 16 mm2
3CC50098AAXX
3CC50099AAXX
3CC50174AAXX
MPR-MPT tool bag (special tools)
Standard tool bag
MPT Extended Power Unit
Nose Adapter for MPT-HC V2/MPT-MC, MPT-XP, and 9558HC
Table 99: Nose Adapter for MPT-HC V2/MPT-MC,MPT-XP, and 9558HC
3DB01460ABXX
3CC50172AAXX
3DB10135AAXX
3CC50125AAXX
5.8 GHz Unlicensed/6 GHz Nose Adapter with waveguide output (for Not
Integrated Antenna)
5.8GHz Unlicensed/6GHz Nose Adapter with N output (for Not Integrated
Antenna)
7/8 GHz Nose Adapter (for Not Integrated Antenna)
11 GHz Nose Adapter (for Not Integrated Antenna)
MPR-e 409
Hardware installation
Table 99: Nose Adapter for MPT-HC V2/MPT-MC,MPT-XP, and 9558HC
3CC50179AAXX
3CC50177AAXX
1
13 GHz Nose Adapter (for Not Integrated Antenna)
15 GHz Nose Adapter (for Not Integrated Antenna)
410 MPR-e
Installation
Table 99: Nose Adapter for MPT-HC V2/MPT-MC,MPT-XP, and 9558HC
3CC50178AAXX
3DB02082AAXX
18/23/25 Nose Adapter (for Not Integrated Antenna)
28/38 Nose Adapter (for Not Integrated Antenna)
1.
MPR-E
Flextwists and N cable for MPT-HC V2/MPT-MC, MPT-XP, and
9558HC
Table 100: Flextwists and N cable for MPT-HC V2/MPT-MC,MPT-XP, and 9558HC
1AF02951ABAA
1AF11977AAAA
3CC05751ACAA
3CC05751ACAA
1
3CC05750ACAA
3CC05749ACAA
3DB00682AAXX
3CC52198ABXX
3CC52198AAXX
5.8 GHz Unlicensed/6 GHz flextwist L = 1m (PDR-UDR)
7/8 GHz flextwist WR112 L = 1m (PDR84/UBR84)
11 GHz flextwist L = 0.6m
13 GHz flextwist L = 0.6m
15 GHz flextwist L = 0.6m
18/23/25 GHz flextwist L = 0.6m
28/38 GHz flextwist L = 0.6m
N-N coaxial cable L=2m
N-N coaxial cable L=1m
1.
MPR-E
Ethernet electrical cables
3CC52141ABAA
3CC52141ACAA
Table 101: Ethernet electrical cables
RJ45-RJ45 Eth. CAT5E shielded straight cable 5 m
RJ45-RJ45 Eth. CAT5E shielded straight cable 15 m
MPR-e 411
Hardware installation
MPR-A indoor installation items
This section includes:
•
Indoor accessories for MPT-HC V2/9558HC and MPT-XP
•
Accessories and cables for MPT-HC V2/MPT-XP/9558HC connections
•
Nose Adapter for MPT-HC V2/MPT-MC, MPT-XP, and 9558HC
•
Flextwists for MPT-HC V2/9558HC and MPT-XP
•
Indoor accessories for MPT-HC V2/9558HC and MPT-XP
3CC52159AAXX
1AB251350001
3CC50030AAAA
Table 102: Indoor accessories for MPT-HC V2/MPT-XP/9558HC
Pigtail
Low Pass Filter
Lighting Arrestor
These accessories must be used to connect the power coaxial cable of
MPT-HC V2/MPT-XP/9558HC to the battery
Accessories and cables for MPT-HC V2/MPT-XP/9558HC connections
3DB18205AAAA
3CC50074ABAA
1AB357780003
Table 103: Accessories and cables for MPT-HC V2/MPT-XP/9558HC
QMA (male)-N (Female) RF cable
Support kit for 4 cord N/QMA MPR IDU
QMA 90° connector for coax. cable (diam.=6.85 mm)
3CC52188AAXX
1AB074610027
1AB150990002
1AD160490001
N-to-Ethernet pair pigtail (N female-Free wires) for the power supply cable (1 m)
RJ45 connector (boot included). To be terminated on the 1 m Adapter cord for Indoor connection or Outdoor connection.
R2CT connector. To be terminated on the 1 m Adapter cord for Outdoor connection.
Tool for HIROSE RJ45 IDU-ODU cable assembling
412 MPR-e
Installation
Table 103: Accessories and cables for MPT-HC V2/MPT-XP/9558HC
1AC016760006
1AD040130004
IDU-ODU Cat5e Ethernet cable (cable to be used for PFoE, with RJ45 and R2CT connectors)
Grounding kit for Cat5e cable
Outdoor Grounding cable 16 mm2 1AC001060084
1AC001100022
1AB095530023
1AB128500002
1AC041350001
1AB095530036
1AD040130004
Coax cable 50 ohm (diam.=10.3 mm) for L>200 m
N Conn. male straight 50 ohm for coax. cable (diam.=10.3 mm)
Grounding kit for coax. cable (diam.=10.3 mm)
Coax. cable 50 ohm (diam.=6.85 mm) for L<200 m
N Conn. male straight 50 ohm for coax. cable (diam.=6.85 mm)
Grounding kit for coax. cable (diam.=6.85 mm)
3CC52170ANXX or
3CC52170BN
3CC52170AMXX or
3CC52170BM
3CC52170AAXX or
3CC52170BA
3CC52170ABXX or
3CC52170BB
3CC52170ACXX or
3CC52170BC
3CC52170ADXX or
3CC52170BD
3CC52170AEXX or
3CC52170BE
LC/Q-XCO to LC Fiber cord (L = 25 m for MPR-e IDU-ODU connection)
LC/Q-XCO to LC Fiber cord (L = 50 m for MPR-e IDU-ODU connection)
LC/Q-XCO to LC Fiber cord (L = 80 m for MPR-e IDU-ODU connection)
LC/Q-XCO to LC Fiber cord (L = 100 m for MPR-e IDU-ODU connection)
LC/Q-XCO to LC Fiber cord (L = 120 m for MPR-e IDU-ODU connection)
LC/Q-XCO to LC Fiber cord (L = 140 m for MPR-e IDU-ODU connection)
LC/Q-XCO to LC Fiber cord (L = 160 m for MPR-e IDU-ODU connection)
MPR-e 413
Hardware installation
3CC52170AFXX or
3CC52170BF
3CC52170AGXX or
3CC52170BG
3CC52170AHXX or
3CC52170BH
3CC52170AIXX or
3CC52170BY
3CC52170ALXX or
3CC52170BL
3CC50097AAXX
Table 103: Accessories and cables for MPT-HC V2/MPT-XP/9558HC
LC/Q-XCO to LC Fiber cord (L = 180 m for MPR-e IDU-ODU connection)
LC/Q-XCO to LC Fiber cord (L = 200 m for MPR-e IDU-ODU connection)
LC/Q-XCO to LC Fiber cord (L = 220 m for MPR-e IDU-ODU connection)
LC/Q-XCO to LC Fiber cord (L = 250 m for MPR-e IDU-ODU connection)
LC/Q-XCO to LC Fiber cord (L = 300 m for MPR-e IDU-ODU connection)
Cable overlength box (wall and pipe mounting only)
3CC52186AAXX
3CC52186ABXX
3CC52186ACXX
3CC52169AAXX or
3CC52169BA
3CC52169ABXX or
3CC52169BB
3CC52169ACXX or
3CC52169BC
3CC52189AAXX or
3CC52189BA
3CC52189ABXX or
3CC52189BB
3CC52189ACXX or
3CC52189BC
XPIC cable cat7 (L = 1 m)
XPIC cable cat7 (L = 2.5 m)
XPIC cable cat7 (L = 8 m)
RPS LC-LC optical jumper preassembled with Q-XCO (L = 1 m)
RPS LC-LC optical jumper preassembled with Q-XCO (L = 10 m for space diversity)
RPS LC-LC optical jumper preassembled with Q-XCO (L = 20 m for space diversity)
RPS Q-XCO to Q-XCO cable (L = 1 m)
RPS Q-XCO to Q-XCO cable (L = 10 m)
RPS Q-XCO to Q-XCO cable (L = 20 m)
3CC50098AAXX
3CC50099AAXX
MPR-MPT tool bag (special tools)
Standard tool bag
414 MPR-e
Installation
3CC50173AAXX
3CC50174AAXX
Table 103: Accessories and cables for MPT-HC V2/MPT-XP/9558HC
MPT Power Unit (includes rack mounting bracket)
MPT Extended Power Unit (includes rack mounting bracket)
Nose Adapter for MPT-HC V2/MPT-MC, MPT-XP, and 9558HC
Table 104: Nose Adapter for MPT-HC V2/MPT-MC,MPT-XP, and 9558HC
3DB01460ABXX
3CC50172AAXX
3DB10135AAXX
3CC50125AAXX
3CC50179AAXX
3CC50177AAXX
1
5.8 GHz Unlicensed/6 GHz Nose Adapter with waveguide output (for Not
Integrated Antenna)
5.8GHz Unlicensed/6GHz Nose Adapter with N output (for Not Integrated
Antenna)
7/8 GHz Nose Adapter (for Not Integrated Antenna)
11 GHz Nose Adapter (for Not Integrated Antenna)
13 GHz Nose Adapter (for Not Integrated Antenna)
15 GHz Nose Adapter (for Not Integrated Antenna)
MPR-e 415
Hardware installation
Table 104: Nose Adapter for MPT-HC V2/MPT-MC,MPT-XP, and 9558HC
3CC50178AAXX
3DB02082AAXX
18/23/25 Nose Adapter (for Not Integrated Antenna)
28/38 Nose Adapter (for Not Integrated Antenna)
1.
MPR-E
Flextwists for MPT-HC V2/9558HC and MPT-XP
1AF02951ABAA
1AF11977AAAA
3CC05751ACAA
3CC05750ACAA
3CC05749ACAA
3DB00682AAXX
Table 105: Flextwists for MPT-HC V2/MPT-XP/9558HC
6 GHz flextwist L = 1m (PDR-UDR)
7/8 GHz flextwist WR112 L = 1m (PDR84/UBR84)
11 GHz flextwist L = 0.6m
15 GHz flextwist L = 0.6m
18/23/25 GHz flextwist L = 0.6m
28/38 GHz flextwist L = 0.6m
Ethernet electrical cables
3CC52141ABAA
3CC52141ACAA
Table 106: Ethernet electrical cables
RJ45-RJ45 Eth. CAT5E shielded straight cable 5 m
RJ45-RJ45 Eth. CAT5E shielded straight cable 15 m
Ethernet optical cables
The following multi-mode jumpers are available:
1AB214000016
1AB214000017
Table 107: Multi-mode Ethernet optical cables
Fiber Simplex MM jumper LC-LC L = 5m
Fiber Simplex MM jumper LC-LC L = 10m
416 MPR-e
Installation
3CC52077AAAA
3CC52078AAAA
3CC52079AAAA
3CC52080AAAA
3CC52081AAAA
3CC52084AAAA
3CC52083AAAA
3CC52085AAAA
3CC52086AAAA
3CC52087AAAA
3CC52088AAAA
3CC52017AAAA
3CC52023AAAA
3CC52025AAAA
3CC52029AAAA
1AB240330033
1AB240330032
1AB200240003
1AB200240004
Table 107: Multi-mode Ethernet optical cables
Fiber Simplex MM jumper LC-FC L = 5m
Fiber Simplex MM jumper LC-FC L = 10m
Fiber Simplex MM jumper LC-SC L = 5m
Fiber Simplex MM jumper LC-SC L = 10m
The following single-mode jumpers are available:
Table 108: Single-mode Ethernet optical cables
Fiber 3M SM LC to LC
Fiber 5M SM LC to LC
Fiber 10M SM LC to LC
Fiber 3M SM LC to FC
Fiber 5M SM LC to FC
Fiber 10M SM LC to FC
Fiber 3M SM LC to SC
Fiber 5M SM LC to SC
Fiber 10M SM LC to SC
Fiber 3M SM LC to SC
Fiber 5M, SM FC-SC
Fiber 10M, SM FC-SC
Fiber 3M, SM SC-SC
Fiber 5M, SM SC-SC
Fiber 10M, SM SC-SC
Antenna alignment
This section includes:
MPR-e 417
Hardware installation
•
•
•
•
Preparation
Warning: to make sure of the continuity and avoid short circuit, all cables / connectors connections such as RJ45, Coaxial, Ethernet, or Optical Fiber made in the field have to be verified and checked with Cable tester. The waterproofness must be also checked.
Before aligning antennas, verify the following:
• The ODUs are powered up at both ends of the link.
• Transmit and receive frequencies are correctly set.
• Transmit powers are correctly set and transmit mute is turned off.
Note: If frequency and/or power settings are not correct for the application, interference may be caused to other links in the same geographical area.
Signal measurement
Two receive signal-strength indicators are provided to assist antenna alignment, RSL in the
Performance screen, and the RSSI voltage at LEMO connector on the MPT-HC V2/MPT-
MC/MPT-XP/9558HC. Refer to:
•
•
Using the RSSI voltage at the MPT-HC V2/MPT-MC/MPT-XP/9558HC
•
Using RSL data
As the MCT is accessed via connection to the Ethernet generic device, a separate means of communication such as two-way radio or cell phone is required between the operator and the person at the antenna.
418 MPR-e
Installation
To align using RSL:
• Monitor RSL in the MCT Performance screen.
• Set antenna alignment for maximum RSL.
• Repeat for the far end of the link.
• Compare actual RSLs with the expected RSLs from the link installation datapack.
RSL measurement accuracies:
→ ± 2 dB for levels -40 to -70 dBm, over a temperature range of 0 to +35°C.
→ ±4 dB for levels -25 to -85 dBm, over an extended -33 to +55°C range.
Using the RSSI voltage at the MPT-HC V2/MPT-MC/MPT-XP/9558HC
A voltmeter, such as a multimeter, is used to measure RSSI voltage.
Use the MPT Service Cord for the power monitoring in addition to a voltmeter.
• Connect a voltmeter to the MPT-HC V2/MPT-MC/MPT-XP/9558HC through the
MPT Service Cord.
• Adjust antenna alignment until the voltage reading is at maximum value.
• Repeat for the far end of the link.
Check and record the peak voltage at each end. The RSSI voltage provides a direct relationship with RSL, as follows:
Table 109: RSSI voltage and RSL
Units Measurement (with MPT-HC V2/MPT-MC/MPT-XP)
Service kit cable (Vdc) 5 4.71
4.12
3.5
2.9
2.3
1.71
1.11
0.59
0.14
-10 -20 -30 -40 -50 -60 -70 -80 -90 -100
• Compare actual RSLs to the expected RSLs from the link installation datapack. See
.
MPT service cord operative information
Figure 356 shows the optional cable P/N 3CC52191AAXX to be used during the
commissioning to point the antenna and connect the MCT directly to the MPR-e (if required).
MPR-e 419
Hardware installation
Figure 356: MPT service cord
Signal
ETH_TXP_T
ETH_TXN_T
GND
ETH_RXP_T
ETH_RXN_T
PRX_OUT
Table 110: Connection table
3
4
5
12
M1
1
2
M2
3
6
—
1
2
—
M3
—
—
—
—
X
M4
—
—
X
—
—
Connector usage:
• (M1) LEMO connector, to be plugged into LEMO connector on MPT-HC V2/MPT-
MC/MPT-XP.
• banana plugs (M3) and (M4): output is a 0 to +5V DC voltage proportional to the radio Rx field. During equipment line–up, through a multi–meter it is possible to easily point the antenna until the measured voltage is the maximum, corresponding to the maximum radio Rx field.
• (M2) RJ45 connector, to connect the WebEML directly to the MPT.
420 MPR-e
Installation
RSL measurement guidelines
RSSI/RSL accuracy
When checking RSSI/RSL against the predicted link values ensure appropriate allowances are made for Tx power-setting accuracy, path-loss calculation accuracy, and RSSI/RSL measurement accuracy.
• For a worst-case the overall accuracy is the sum of the individual accuracy limits, which for a link would be ±4 dB of the predicted value (±2 dB for transmit, ±2 dB for receive, 0 to 35°C), aside from the path-loss calculation accuracy, which should be within limits of ±3 dB.
• Typically, where the measured RSSI/RSL is more than 4 dB lower than the expected receive level you should check the path survey results, path calculations and antenna alignment.
Note: When checking RSSI/RSL ensure the measurement is made under normal, unfaded and interference-free path conditions.
• A discrepancy of 20 dB or greater between the measured and calculated RSSI/ RSLs suggests an antenna is aligned on a side lobe, or there is a polarization mismatch.
Note: Without any received signal (Tx mute on the remote MPT for example), the RSL value displayed may be more than -100dBm. This depends of the channelisation/modulation settings
Aligning the antenna
Antenna alignment involves adjusting the direction of each antenna until the received signal strength reaches its maximum level at each end of the link. Fine adjustment for azimuth
(horizontal angle) and elevation (vertical angle) is built into each antenna mount.
Adjustment procedures will be provided with each antenna.If the horizontal adjuster does not provide sufficient range to locate the main beam, the antenna mounting brackets will need to be loosened and the antenna swiveled on its pole mount to locate the beam.
Before doing this ensure the horizontal adjuster is set for mid-travel.
Some mounts for larger antennas have a separately clamped swivel base to allow the loosened antenna to swivel on it without fear of slippage down the pole. Where such a mount is not provided, a temporary swivel clamp can often be provided using a pair of pipe brackets bolted together immediately below the antenna mount.
MPR-e 421
Hardware installation
Note: Ensure antennas are aligned on the main beam, and not a side lobe.
For guidance, see the sections
Verify that ATPC is turned off during the alignment procedure.
Standard alignment procedure
To align an antenna:
• Loosen the azimuth adjuster on the antenna mount (horizontal angle) and adjust azimuth position for maximum signal strength. Ensure antennas are aligned on the main beam, and not a side lobe.
• Tighten the azimuth securing mechanism. Ensure signal strength does not drop as it is tightened.
• Loosen the elevation adjuster (vertical angle) and adjust for maximum signal strength. Ensure antennas are aligned on the main beam, and not a side lobe.
• Tighten the elevation securing mechanism. Ensure signal strength does not drop as it is tightened. The terminal is now aligned and ready to carry operational traffic.
• Record RSL and/or RSSI voltage in the commissioning log.
Additional procedure for CCDP XPIC links with MPT-HC V2/MPT-XP
Note: Procedures are provided for the alignment of dual polarized antennas, and for protected XPIC links.
For CCDP (Co-channel Dual Polarized) XPIC (Cross Polarized Interference Cancellation) links it is important that antenna feeds are correctly aligned to achieve optimum XPIC performance.
While a dual-feed antenna may be specified with a cross polarization discrimination of 30 dB, unless the antenna-to-antenna alignment over a link is correct, the effective discrimination can be significantly less.
• The horizontal-to-vertical receive signal discrimination for satisfactory XPIC operation must not be less than 25 dB, and where possible should be set for optimum discrimination using this procedure.
422 MPR-e
Installation
• High performance shielded antennas typically exhibit 30 dB cross polarization discrimination whereas 40 dB is typical for purpose-designed, high polarization discrimination antennas.
• The received-signal V and H discrimination can be checked using the Radio
Synthesis tab-panel of the MPT-HC V2/MPT-XP/9558HC, as shown in Figure 357 .
Figure 357: XPD measurement
The cross pole discrimination measures the V and H signal discrimination in dB at the input to the MPT-HC V2/MPT-XP/9558HC (from the antenna feeds). The improvement in signal discrimination provided by the XPIC function is in addition to this measurement.
Note: This alignment procedure is intended for dual-polarized antennas, but is also generally applicable to installations using separate antennas for V and H planes.
Alignment procedure for dual polarized antenna
The following procedure details steps required to:
• Check and if necessary set feedhead alignment using a spirit level.
• Align the antennas at each end using just one of the feeds, H or V (Standard co-plane antenna alignment).
→ Where the V and H waveguide ports on an antenna are not marked they can be identified by the orientation of the waveguide slots.
→ Where a dual-polarized antenna presents the same orientation on both ports, one should have a straight waveguide feed to the antenna feedhead, the other will include a 90 degree twist or have a straight waveguide feed but with a polarization rotator in the feedhead. Generally the polarization rotator will act on the outer-most waveguide on the feedhead.
MPR-e 423
Hardware installation
→ For convention, if ports are not marked for V and H, it is recommended that the port that has the straight waveguide feed or is connected to the inner-most waveguide at the feedhead is selected as the horizontal antenna feed port. The following graphic of an antenna feedhead assembly illustrates this. The top port is connected to the inner feed on the feedhead, and with the port orientation shown provides a horizontally polarized feed. The lower port has a rotator included in the feedhead to provide a vertical feed.
424
Ensure the same port is selected for vertical at both ends.
Where possible, the same ‘above and below’ relationship of the feed ports should be used at both ends. For example, if at one end the horizontal feed port is located above the vertical port, as in the example above, then the same relationship should be used at the other end.
• Check cross pole discrimination (XPD) in the Measurement tab-panel of the
MPT-HC V2/MPT-XP.
• Optimize alignment of the feed-heads to achieve maximum cross polarization discrimination.
Note: This procedure assumes that the antennas used at each end of the link do comply with their cross-polarization discrimination specification. If in doubt, refer to the antenna supplier.
Procedure:
1. Static feedhead alignment
During antenna installation and before weatherproofing is installed, use a spirit level to check and set exact vertical / horizontal alignment of the feeds. This step should be completed in conjunction with antenna alignment, step 2, to ensure no misalignment of skew angle is introduced during the pan and tilt process.It should be completed before any feedhead weatherproofing is applied, so that a spirit level can be used against the flange to check and set precise physical vertical/horizontal alignment of the feeds: a. Do not rely on antenna markings as these will not be accurate where a mount is not perfectly level. b. Set the spirit level against the flange of the feedhead. Take care that only the flange of the feedhead is measured, so that no error is introduced by any minor misalignment of the mating flexible waveguide flange. See
MPR-e
Figure 358: Checking feedhead flange with a spirit level
Installation
MPR-e c. If not exactly vertical or horizontal, adjust the feedhead skew angle (rotate the feedhead) until correct (spirit level bubble is precisely centered). For a typical feedhead check both flanges for level, using an end point half way between the level points of the two flanges should there be any discrepancy between the two.
2. Align antennas
Align the antennas at both ends using the standard (co-plane) alignment procedure, but using just one of the feeds, V or H. Refer to
Standard alignment procedure .
If major adjustment to the pointing of the antenna is made during this process, recheck the feedhead skew angle.
When correct, proceed to step 3.
3. Check operation and end-end feedhead alignment
Power-up both V and H links and check they are operating normally and are alarmfree. Use the Measurement tab-panel of the MPT-HC V2/MPT-XP to check that:
→ Tx power measurements are within 1 dB (typically). If not check Tx power settings.
→ RSL measurements are within 2 dB. See
Using RSL data for guidance on
measurement accuracy.
→ Links are operating error-free.
Note: Where there is potential for interference from other links in the same geographical area, check by turning the far end transmitter(s) off and measuring the local end RSL on both V and H feeds.
425
Hardware installation
4. Use the cross pole discrimination (XPD) measurement provided in the Measurement tab-panel of the MPT-HC V2/MPT-XP to measure the actual V and H signal discrimination from each antenna.
→ Where measured XPDs are better than 25 dB no further adjustment is needed
→ Where less than 25 dB proceed to the next step.
Caution: It is possible for a spurious XPD figure of about 50 dB to appear in instances where there is major mis-alignment. Note that the raw XPD should never read higher than the XPD specification of the antennas, which for most high performance dual-pol antennas will be between 30 dB to 35 dB.
Note: The alignment procedures listed under steps 1 and 2 should result in a discrimination of better than 25 dB, as measured in the Measurement tab-panel of the MPT-HC V2/
MPT-XP, which is comfortably within the operating limits of XPIC. However, for best results and greater operating margins during fading, feedhead alignment should be optimized using the following procedure.
5. Optimize end-end feedhead alignment
This procedure corrects for any minor rotational alignment between antennas at each end.
One antenna is the reference antenna and its feed-head assembly is not adjusted during this procedure.
Note: Only check/adjust skew angles on one antenna. If both antennas are adjusted and re-adjusted there is potential for progressive misalignment to occur. Select one antenna as the reference antenna. On long hops and where fading is prevalent there is potential for the
V and H plane paths to be affected differently and to therefore exhibit variable crosspolarization discrimination. This alignment procedure must be conducted during periods of known, stable path conditions.
6. Determine which end of the link is to provide the reference antenna, and at the opposite end open the Measurement tab-panel of the MPT-HC V2/MPT-XP for the
V and H.
7. Adjust the feedhead skew angle of the antenna for maximum XPD on both V and H link. If the maximums for each are at (slightly) different angles, adjust for a midpoint.
426 MPR-e
Installation
Note: Ensure that as you adjust the skew angle, the physical antenna alignment does not shift, which would make it necessary to repeat step 2. Check that antenna mounting bolts and azimuth and elevation adjuster locks have been correctly tightened.The maximum points may be quite sharp, rotate the feedhead slowly to ensure they are not missed.
8. Check the XPD on the link at the reference end of the link, which should be within 1 to 2 dB of the measurements at the adjusted end.
9. On completion ensure feedhead bolts are correctly tightened - check that XPDs do not change during tightening.
10. Retain feed-head adjustment data for the commissioning records.
Main beams and side lobes
This section describes:
•
•
Locating the main beam
Ensure the antennas are aligned on the main beam, and not a side lobe.
Once a measurable signal is observed, very small alignment adjustments are required to locate the main beam. For instance, a 1.2m antenna at 23 GHz typically has 0.9° of adjustment from center of main beam to the first null (0.4° to the -3 dB point). Antenna movement across the main beam will result in a rapid rise and fall of signal level. As a guide, 1 degree of beam width is equivalent to moving approximately 1.0 mm around a standard 114 mm (4.5 in.) diameter O/D pipe.
Antennas can be verified as being on main beam (as opposed to a side lobe) by comparing measured receive signal level with the calculated level.
Signal strength readings are usually measurable when at least a main beam at one end and first side lobes at the other are aligned.
The strongest signal occurs at the center of the main beam. The highest first lobe signal is typically 20 - 25 dB less than the main beam signal. When both antennas are aligned for maximum main beam signal strength, the receive signal level should be within 2 dB of the calculated level for the path. This calculated level should be included in the installation datapack for the link.
MPR-e 427
Hardware installation
Figure 359 is an example of a head-on, conceptual view of the beam signal strength, with
concentric rings of side lobe peaks and troughs radiating outward from the main beam.
Figure 359: Indicative head-on signal pattern for a parabolic antenna
Tracking path error
Side lobe signal readings can be confused with main beam readings. This is particularly true for the first side lobe as the signal level at its center is greater than the signal level at the edges of the main beam, and if tracking on an incorrect elevation (or azimuth) a false impression of main beam reception can be obtained. This illustration shows an example of this with a simplified head-on view of an antenna radiation pattern, and tracking paths for three elevation settings.
Figure 360: Example tracking path signals
428 MPR-e
Installation
Line AA represents the azimuth tracking path of a properly aligned antenna.The main beam is at point 2, and the first side lobes at points 1 and 3. Line BB represents the azimuth tracking path with the antenna tilted down slightly. Signal strength readings show only the first side lobe peaks, 4 and 5. In some instances the side lobe peaks are unequal due to antenna characteristics, which can lead to the larger peak being mistaken for the main beam. The correct method for locating the main beam in this case is to set the azimuth position midway between the first side lobe peaks, and then adjust the elevation for maximum signal.
Line CC represents an azimuth tracking path with the antenna tilted down further still. The first side lobe signal peaks (6 and 7) appear as one peak, leading to a mistaken interpretation of a main beam. The correct method for locating the main beam is to set the azimuth at mid peak, between 6 and 7, and then adjust elevation for maximum signal.
This first side lobe peaking is probably the most frequent cause of misalignment in both azimuth and elevation, especially so if one side lobe peaks higher than the other, as shown in
Figure 361 . A common error is to move the antenna left to right along line DD, or top to
bottom along line EE, always ending up with the maximum signal at position 1.
Figure 361: Example tracking path signals on the first side lobe
Software local copy
This section explains how to prepare the TCO Suite and Craft Terminal environment in your
PC.
•
•
•
Local copy of the Software Package (SWP) to the PC
MPR-e 429
Software local copy
•
Local copy of the WebEML to PC
Getting started
Note: Read the following before starting.
• The operator must be familiar with the use of personal computers in WINDOWS environment, internally from which the NE application software operates.
• TCO Software Suite is on one CD. Software Package (SWP) is on another CD.
Verify versions of the CD-ROM.
• To properly install TCO Software Suite, a PC is required, having the characteristics specified in
PC characteristics
The PC to use must meet the following characteristics:
PC Hardware Configuration:
• CPU: AMD Atlhon/Intel Celeron/Intel Pentium 4 or higher
• RAM: 1 GB
• Hard Disk space: 1.5 GB (available space for log files, JRE excluded)
• Display Resolution: 1280x800 pixel
• DVD-ROM Drive: needed for the TCO Suite
• Ethernet Interface: Ethernet card 10/100/1000 Mbps
• VLAN tagging capability (if PC used on MPR-e traffic port for provisioning or lineup)
Operating Systems Supported
Windows XP
Windows 7 (Note)
Table 111: PC characteristics
Version
Professional Ed. SP3
Professional and Ultimate
430 MPR-e
Installation
Additional requirements
Java JRE
MS IE Explorer
Firefox
Chrome
FTP Servers (for SW download feature)
1.
"Classic windows" setting must be chosen with Windows 7.
Table 112: Additional requirements
Version
Version 7, Update 17, 32 bit only (included on DVD-ROM TCO
SW Suite R5.0)
Version 8 with Windows XP, version 9 or higher with Windows
7
Version 12 or higher
Version 20 or higher
Tested FTP versions:
Apache FTP Server
(http:/incubator.apache.org/ftpserver/). Default available with WebEML (JUSM/CT);
VSFTPD, version 2.0.5;
FileZilla FTP Server, version 0.9.41
Warning: An FTP Server must be installed on the PC with read & write permissions, and the Windows Firewall must be deactivated.
Local copy of the Software Package (SWP) to the PC
Follow these steps to copy the Software Package (SWP) to the PC.
1. Insert the SWP CD into the CD-ROM drive.
Note: The Software Package will auto-run and open up the computer's default browser program (if auto-run feature is enabled on user's PC) as soon as the CD-ROM is read by the PC. If auto-run does not start, the user must run (double-click) the autorun.exe file, available on CD-ROM root, to launch the Software Package.
MPR-e 431
Software local copy
Figure 362: SWP main menu
2. Click on the Local Copy button to copy the software to your local PC.
3. Click on the Start Copying button.
4. Choose a directory location for the Local Copy of Software Package. Select the directory and click on OK to begin the copy process.
Warning: Special characters (like #...) cannot be used.
Warning: If the Apache FTP server (embedded in the TCO SW Suite) is used, it is mandatory to save the SW component in the directory: "\Documents and Settings\<login name>\9500MPR-E\res\home" as shown in
432 MPR-e
Installation
Figure 363: Directory for the SW component if Apache FTP server is in use
5. The files will be copied from the CD to the PC and will create a directory named
ECT.
6. A successful copy message will display, when all files have been copied. Click OK.
7. Remove the SWP CD from the CD-ROM drive.
Local copy of the WebEML to PC
Follow these steps to copy the WebEML to the PC.
1. Insert the TCO Suite R5.0 CD into the DVD-ROM drive.
Note: The TCO Suite R5.0 software will auto-run and open up the computer's default browser program (if auto-run feature is enabled on user's PC) as soon as the DVD-ROM is read by the PC. If auto-run does not start, user must run (double-click) the Start.exe file, available on DVD-ROM root, in order to launch the Software Package.
2. The following screen opens.
MPR-e 433
Software local copy
434
3. Click on the MPR-e icon to perform the Local Copy of the WebEML. The Local
Copy Management window opens.
Figure 364: Local Copy Management window
4. Click No. A confirmation window opens.
5. Click Yes to perform the WebEML Local Copy. The Local Copy Selector window opens.
MPR-e
Figure 365: Local copy selector window
Installation
MPR-e
6. Select the SW component to copy and click on Copy.
7. Select the directory and click Open.
Warning: Special characters (like #...) cannot be used.
8. The copy is now in progress.
435
Software local copy
9. Wait until the following message will appear. Click OK.
Figure 366: Successful copy
436
10. Click Yes to set a link on the desktop.
11. Perform one of the following: a. Double click on the WebEML icon on the desktop to start the application for
MPR-e standalone.
Figure 367: Desktop icon
b. Double click on the MCT Launcher icon on the desktop to start the application for MPR-e in Single NE mode with 7705 SAR (applicable to 9500 MPR Release
4.1.0).
Figure 368: MCT Launcher
An alternative way to perform the Local Copy of the WebEML is the following:
MPR-e
1. Click on the Advanced Settings button in the Main Menu.
Figure 369: Main menu
Installation
MPR-e
2. Select one of the two Advanced Settings options to copy software to the PC.
→
→
Local copy of WebEML (JUSM/CT)
437
Software local copy
Figure 370: Advanced install settings
Java JRE package installation
Click on the Java JRE Package Installation button to install the Sun Java Runtime
Environment (JRE) 7 Update 17 version to your PC.
Local copy of WebEML (JUSM/CT)
1. Click on the Local Copy of WebEML (JUSM/CT) button to copy the WebEML software to your PC. Choose the directory location and click Open and then OK.
Warning: Special characters (like #...) cannot be used.
438 MPR-e
Installation
MPR-e
2. When the files have finished copying, this window will display. Click the OK button.
Figure 371: Successful copy
3. Click Yes to set a link on the desktop.
4. Two icons will be created on the desktop: one for the WebEML (used for MPR-e standalone) and one for the MCT Launcher (used for MPR-e Release 4.1.0 in Single
NE with SAR).
Figure 372: WebEML desktop icon
439
Software local copy
Figure 373: MCT Launcher desktop icon
Configure the PC Network card for the connection to the
MPR-e standalone
Two options are available:
•
Option 1: PC connected to the traffic port of MPT
•
Option 2: PC connected to Ethernet generic device
Note: Option 1 is mandatory for 1+0 repeater configuration.
Option 1: PC connected to the traffic port of MPT
This example uses a Microsoft Windows 7 Professional system and refers to the first installation (default values), when the MPR-e has never been configured.
1. Connect a CAT 5/5E cable from the MPR-e to the PC network card.
2. Open Network Connections and highlight the network card as shown in
440 MPR-e
Figure 374: Network card
Installation
3. Open the Properties menu and click on Configure.
Figure 375: Local area connection properties
MPR-e
4. Enable VLAN management.
441
Software local copy
Figure 376: Enable VLAN management
5. Provision the Network Address.
a. In the Local Area Connection Properties window, choose Internet Protocol
(TCP/IP).
b. Click on Properties. The Internet Protocol (TCP/IP) Properties window opens.
442 MPR-e
MPR-e
Figure 377: Local area connection properties
Installation c. In the Internet Protocol (TCP/IP) properties window, choose Use the following
IP address, and configure the parameters for the NE.
The PC must be in the same sub network as the IP interface on the MDA card of the 7705 SAR.
443
Software local copy
Figure 378: TCP/IP properties
Option 2: PC connected to Ethernet generic device
This example uses a Microsoft Windows XP Professional system and refers to the first installation (default values), when the MPR-e has never been configured.
1. Connect a CAT 5/5E cable from the PC network card to the MCT connector on FE port of the Ethernet generic device.
2. Click on the Start menu on the Windows desktop and open the Control Panel.
3. Open Network Connections. Highlight the network card as shown in Figure 33 .
Figure 379: Network card highlighted in Network Connections
444
4. Double click on Properties to display the screen shown in
Internet Protocol (TCP/IP) and on Properties. The Internet Protocol (TCP/IP)
Properties window opens, as shown in Figure 380
.
MPR-e
MPR-e
Figure 380: Click on Properties
Installation
5. In the Internet Protocol (TCP/IP) Properties window, enter, for example, the IP address 192.168.100.2 (subnet mask: 255.255.255.0) for the PC network card as shown below. Click OK.
Figure 381: TCP/IP properties
445
Software local copy
Note: The NE default IP address is 192.168.100.1 (mask 255.255.255.0); for this reason the PC IP address must belong to the same mask.
Note: It is suggested to keep only one enabled network connection on a PC.
6. To check the connectivity between the PC and the NE, open a command window.
Click on the Start menu on the Windows desktop and open the Run window as shown in Figure 36 .
Figure 382: Run window
7. Type cmd and click OK to open a command window.
The command window opens.
446 MPR-e
MPR-e
Figure 383: Command window
Installation
8. In the command window, type ping 192.168.100.1 to verify a connection between the PC and the NE. The Ping statistics for the IP address 192.168.100.1 should display 4 packets sent and 4 packets received.
Note: The 192.168.100.1 IP address is the default NE In-band IP address.
447
Software local copy
Figure 384: Ping the default NE In-band IP address
Possible error messages
Start supervision failure
448 MPR-e
MPR-e
Figure 385: Start supervision failure error message
Installation
Action > Verify IP connectivity with ping
Impossible to connect
449
Software local copy
Figure 386: Impossible to get connection error message
Action > Only one MCT session can be open on a MPR-e. Verify that no PC is already connected on the NE.
Configure the PC Network card for connection to the MPRe in Single NE mode with 7705 SAR
When in Single NE mode with 7705 SAR, the access to MPR-e is dictated by 7705 SAR reachability from the local PC, with the 7705 SAR as the connection gateway.
There are two main options to connect to MPR-e:
•
Option 1: PC connected to CSM management port
•
Option 2: PC connected to Ethernet MDA port
450 MPR-e
Installation
Option 1: PC connected to CSM management port
This example uses a Microsoft Windows XP Professional system and refers to the first installation (default values), when the MPR-e has never been configured.
1. Connect a CAT 5/5E cable from the PC network card to the FE port of the Ethernet generic device.
2. Click on the Start menu on the Windows desktop and open the Control Panel.
3. Open Network Connections. Highlight the network card as shown in Figure 33 .
4. Double click on Properties and scroll down the list to highlight the Internet Protocol
(TCP/IP) line. Click on Properties.
5. Enter, for example, the IP address 192.168.100.2 (subnet mask: 255.255.255.0) for
the PC network card as shown in Figure 381
. Click OK.
Note: The PC IP address must belong to the same subnet mask as the IP address of the management port of the 7705 SAR.
Note: It is suggested to keep only one enabled network connection on a PC.
6. To check the connectivity between the PC and the NE, open a command window.
Click on the START menu on the Windows desktop and open the Run window as shown in Figure 36 .
7. Type cmd and click OK to open a command window.
In the command window, type ping 192.168.100.1 to verify a connection between the PC and the NE. The Ping statistics for the IP address 192.168.100.1 should display 4 packets sent and 4 packets received, as shown in Figure 38 .
Note: The 192.168.100.1 IP address is the default NE In-band IP address.
Option 2: PC connected to Ethernet MDA port
When the PC is connected to any Ethernet MDA port, port encapsulation drives the PC network adapter configuration.
MPR-e 451
Software local copy
If the configured encapsulation is dot1q, a VLAN must be configured on the PC network adapter. If encapsulation is null, no VLAN tag is required and the configuration steps are
exactly the same as for Option 1: PC connected to CSM management port
.
This example uses a Microsoft Windows 7 Professional system and refers to the first installation (default values), when the MPR-e has never been configured.
1. Connect a CAT 5/5E cable from the MPR-e to the PC network card.
2. Open Network Connections. Highlight the network card as shown in
3. Open the Properties menu and Click on Configure, as shown in
4. Enable VLAN management, as shown in
5. Provision the Network Address.
a. In the Local Area Connection Properties window, choose Internet Protocol
(TCP/IP).
b. Click on Properties. The Internet Protocol (TCP/IP) Properties window opens, as shown in
c. In the Internet Protocol (TCP/IP) properties window, choose Use the following
IP address, and configure the parameters for the NE.
The default IP address for TMN in Band is 192.168.100.1.
The PC must be in the same sub network.
Possible error messages
Error reported when clicking on MPR-e not connected to a 7705 SAR, either because it is powered off or because Ethernet cable is not connected at one or both ends.
452 MPR-e
MPR-e
Figure 387: Unavailable MPR-e error
Installation
Error reported when connection with the 7705 SAR is lost. The MCT Launcher will close, along with all MCT sessions.
Figure 388: MCT sudden closure
453
Software local copy
Figure 389: MCT Launcher sudden closure
454 MPR-e
Provisioning
MPR-e standalone provisioning
Provisioning through
Option 1
(PC)
Option 2
(Ethernet generic
Device)
This chapter describes the first installation procedures to configure the NE.
Since MPR-e is a stand alone equipment, for its provisioning there are 2 possible options:
•
Option 1: MPR-e configured through the PC
•
Option 2: MPR-e configured directly through Ethernet generic device
Table 113 provides an overview of the options detailed in this chapter.
Option B
Optical
Option A
Electrical
Option B
Optical
Option A
Electrical
Table 113: Provisioning options
Ethernet generic
Device connectivity
-
MPT-MC
-
MPR-e can always be installed on pole mounting before provisioning
MPR-e can always be installed on pole mounting before provisioning
MPT-HC V2/
MPT-XP/
9558HC
Provisioning must be performed before HW installation of MPT
MPR-e can always be installed on pole mounting before provisioning
MPR-e can always be installed on pole mounting before provisioning
Note: For the provisioning of the 1+0 repeater configuration, Option 1B is applicable.
MPR-e 455
MPR-e standalone provisioning
Option 1: MPR-e configured through the PC
Prerequisites for the PC
• 1 Gb Ethernet interface (mandatory)
• VLAN management capability
• For the configuration see
Configure the PC Network card for the connection to the
.
MPR-e interconnection options
MPR-e standalone: Installation & interconnection overview describes the possible options
for hardware installation after provisioning of the equipment.
MPT-MC can only be connected through electrical connection.
Table 114 is the summary table.
Connection
Optical
Electrical
DC
Data
DC
Data
Table 114: MPR-e interconnection options
MPT-HC V2/
MPT-XP/
9558HC
Coaxial cable
Fiber cable
CAT5e cable (PFoE)
-
MPT-MC
CAT5e cable (PFoE)
Option A: MPR-e is interconnected to the Ethernet generic device in electrical
MPR-e can always be installed on the pole mounting before provisioning.
456 MPR-e
Provisioning
Option B: MPR-e is interconnected to the Ethernet generic device in optical
The configuration will not be possible from PC through SFP optical port (no PC are equipped), as consequence the provisioning must be performed through electrical interface
BEFORE to install the MPR-e on the pole mounting with its final optical connectors.
Procedure
1. Set up the interconnections to MPR-e in electrical:
→ MPT-MC/MPT-HC V2/MPT-XP/9558HC interconnection:
MPR-e
Note: MPT-MC/MPT-HC V2/MPT-XP/9558HC can be installed on the pole-mounting.
3. Configure the PC network card interface. See
Configure the PC Network card for the connection to the MPR-e standalone .
4. Start the WebEML following the procedure in
Depending on the WebEML version you are using and the MPR-e Software Package version (NE release) loaded in the MPR-e, you can experience 2 different situations:
457
MPR-e standalone provisioning
→ Situation 1: the main screen of the MPR-e opens. You have to check whether the
MPR-e Software Package version must be updated. If needed, proceed as described in
Software download for MPR-e standalone .
→ Situation 2: You are not able to click on the Show button of the NEtO and a popup message indicating a version mismatch is displayed:
458
This means that the MPR-e Software Package version is newer than the
WebEML version. For example, in the picture, the NE Software Package loaded in the MPR-e is Rel 4.0.0, while the most recent WebEML version is Rel 3.4.0.
Note: Alcatel-Lucent regularly introduces new NE release in production that may be not the one you are using on your network.
5. In such case, press the Yes button in the Version mismatch to have access to the Show button in the NEtO window.
6. Click on the Show button. The message in
MPR-e
Figure 390: Version mismatch
Provisioning
7. Click on the Downgrade NE button to downgrade the NE Software Package. The screen in
Figure 391: Downgrade NE
MPR-e
Warning: After the activation of the Standby bank, the connection between WebEML and
MPR-e is lost.
459
MPR-e standalone provisioning
8. Proceed as described in Software download for MPR-e standalone . The MPR-e will
reset after the activation of the Standby Software Package, causing the loss of the connection.
9. Re-open the WebEML.
Figure 392: WebEML for MPR-e standalone
10. Configure all the MPR-e parameters in the Commissioning > Configuration menu
Note: (For MPT-HC V2 and MPT-XP only) If the XPIC Configuration has been selected or in 1+0 repeater configuration, the second MPT-HC V2/MPT-XP-9558HC must also be configured.
11. The MPR-e is now ready for MPR-e standalone application. Disconnect the MPR-e from the PC and connect it to the Ethernet generic device.
Option 2: MPR-e configured directly through Ethernet
460 MPR-e
Provisioning
generic device
Pre requisites for the Ethernet generic device
See
Ethernet generic device prerequisites
.
Note: in this situation the MPR-e can always be installed on the pole mounting before provisioning.
Procedure
1. Set up the interconnections as shown in
MPR-e standalone: Installation & interconnection overview .
2. Verify on the PC, that the WebEML application has been installed (if not, refer to
Local copy of the WebEML to PC
to install it).
4. Start the WebEML following the procedure in
See step
Option B: MPR-e is interconnected to the
Ethernet generic device in optical .
MPR-e provisioning in Single NE mode with
7705 SAR
7705 SAR pre-requisites
See
7705 SAR platform prerequisites .
Procedure
1. Set up the interconnections, as shown in Figure 208
.
MPR-e 461
MPR-e provisioning in Single NE mode with 7705 SAR
2. Verify on the PC that the MCT Launcher application has been installed (if not, see
Local copy of the WebEML to PC
to install it).
4. Start the MCT Launcher following
7705 SAR and MPR-e in Single NE: MCT
. The main screen of the MCT Launcher opens.
5. Configure all the MPR-e parameters in the Commissioning > Configuration menu
Note: (For MPT-HC V2 and MPT-XP only) If the XPIC Configuration has been selected or in 1+0 repeater configuration, the second MPT-HC V2/MPT-XP must also be configured.
The MPR-e is now ready.
462 MPR-e
Maintenance and trouble-clearing
Introduction
This section contains information and procedures to aid in restoring the equipment to its proper operating condition after it has been determined that a problem exists.
The following warnings and cautions apply while operating, performance testing, troubleshooting, or repairing the 9500 MPR series radios.
Danger: Short circuits in low-voltage, low-impedance dc circuits can cause severe arcing that may result in burns or eye injury. Remove rings, watches, and other metal jewelry while working with primary circuits.
Exercise caution to avoid shorting power input terminals.
Caution: Units with the electrostatic-sensitive (ESS) symbol contain ESS devices. Store these units in an antistatic container when not in use, and anyone handling a unit should observe antistatic precautions.
Refer to the Special Precautions pages in the front of the instruction book for detailed handling information.
Note: Ensure that all antennas are properly aligned and waveguide is in good physical condition.
Note: Before performing procedures that might in any way affect transmission, it is recommended that the person performing the procedure understand the Rules and
Regulations pertaining to the equipment and be properly authorized to operate the equipment.
MPR-e 463
Maintenance philosophy
Maintenance philosophy
This section provides information and procedures for equipment maintenance down to the
Card level. Card repair is not covered in this manual.
The use of maintenance procedures in this section may result from failure of a periodic check, an alarm indication, or unacceptable performance.
This document addresses only the MPR-e maintenance. For information about Maintenance on MPR-e directly connected to a 7705 SAR system, see the 7705 SAR documentation. In addition, considering the level of integration between two systems and their joint behavior, maintenance operation must always involve people with knowledge of both MPR-e and the
7705 SAR.
Personal computer (PC)/laptop
Connect the PC to the FE port of the Ethernet generic device.
Troubleshooting
This section provides guidance on:
•
Before going to site checklist
•
•
•
Relationship between the alarms on the MCT and SNMP traps
•
Before going to site checklist
Where possible, before going to site obtain the following information:
• Does the fault require immediate attention?
• Determine who is the best-placed person to attend the fault.
464 MPR-e
Maintenance and trouble-clearing
• Confirm the nature and severity of the reported fault, its location, MPT type, frequency band, high/low end MPT, capacity modulation and configuration (non protected, protected, diversity). Ask:
→ Is just one link affected, or a number of links in the same geographical area?
→ Is the path down completely or is traffic passing but with a BER alarm?
→ Could the fault be in the equipment connected to MPT, rather than in MPT? Are there alarms on other, connected equipment?
→ Is it a hard or intermittent fault?
→ Do alarms confirm which end of an alarmed link is faulty?
• Could the weather (rain, ice, high wind, temperature) be a factor in the reported fault?
Note: If the fault suggests a rain fade or other weather related fade condition and it matches the prevailing weather conditions, do not take any action until the weather abates.
• Does link history suggest any fault trends?
→ Does the fault history for the link indicate a likely cause?
→ Is the link newly installed?
→ Has there been any recent work done on the link?
• Ensure that you have with you:
→ Appropriate spares. Where an equipment failure is suspected, these should include replacement of the MPR-e. If an MPR-e is suspected then local/national climbing safety requirements must be adhered to.
→ A laptop PC loaded with Craft Terminal, and an Ethernet cable. If an Ethernet connection is to be used, you need the IP address and also the addresses for any remote sites to be accessed.
→ If login security has been enabled, you need the password for the local and also any remote sites to be accessed.
→ Any special test equipment that may be needed, such as a BER tester.
→ Toolkit.
→ Keys for access to the site.
PC troubleshooting
If the NE is not displayed in the NEtO screen, the MCT has to be launched directly through
MctStarter.jar located under the path created by the operator during the local copy and under
\\WebEML MPR TCO R5.0\9500MCT_V08.0X.XX\MctStarter.jar
MPR-e 465
Troubleshooting
Troubleshooting basics
This section provides general guidance on troubleshooting.
Check the MCT screen
Connect the PC to the Ethernet generic device. When logging to the equipment with the Craft
Terminal, the opening screen is the Main Screen. Use the information provided in
and
Events to check for severity and problem type.
, and Table 117 for probable cause and recommended action.
Alarm description
Table 115: MPT-HC V2/MPT-MC/MPT-XP/9558HC alarm matrix (equipment type)
MPT Card fail
(Tx fail, Rx fail, Mod fail)
MPT Module
Card Fail (***)
Alarm displayed on MCT
Probable cause
Replaceable Unit
Problem (RUP)
Replaceable Unit
Problem (RUP)
Specific Problem
Tx BB LO
Unlocked
RF LO Unlocked
Rx IF LO
Unlocked
Rx BB LO
Unlocked
Modem Tx
Synchronization
Tx Power
MPT Plug-in RI
Access Failure if XPIC plug-in add;
XPIC Plug-in
Power Supply
Failure;
XPIC Inter-
Modem
Calibration
Failure
Filtering rule
no no
1
Most probable cause
MPT failed
MPT failed
Action
Replace the
MPT
Replace the
MPT
466 MPR-e
Maintenance and trouble-clearing
Alarm description
SFP traffic missing
Traffic SFP card fail
Incompatible
Shifter
Incompatible
Frequency
Incompatible
Modulation
Incompatible
Power
XPIC cable loss (*)
Coupling port
SFP missing
(*)
Coupling port
SFP card fail
(*)
Table 115: MPT-HC V2/MPT-MC/MPT-XP/9558HC alarm matrix (equipment type)
Alarm displayed on MCT
Probable cause Specific Problem
Replaceable Unit
Missing
Filtering rule
no
1
Most probable cause
Action
Replaceable Unit
Problem (RUP)
Incompatible
Shifter
Incompatible
Frequency
Incompatible
Modulation
Incompatible
Power
Demodulator
XPIC Loss Of
Signal
Replaceable Unit
Missing
Replaceable Unit
Problem (RUP)
SFP traffic missing no
Incompatible
Shifter no no
MPT Module
Card Fail no
Coupling Port
SFP missing
SFP traffic missing or type mismatch
The optical SFP is failed
Configured shifter value not supported by the
MPT
Configured frequency value not supported by the MPT
Configured modulation value not supported by the MPT
Configured Tx
Power value not supported by the
MPT
Loss of Signal on the XPIC interface
The SFP plug-in is missing or type mismatched
The SFP plug-in is failed
Plug or check the optical
SFP
Replace the optical SFP
Re-configure shifter value
Re-configure frequency value
Re-configure modulation value
Re-configure
Tx Power value
Check the cable
Plug or check the SFP plugin
Replace the
SFP plug-in
Legend:
• (*): only for MPT-HC V2/MPT-XP in XPIC configuration
• (***): only for MPT-HC V2/MPT-XP/9558HC
MPR-e 467
Troubleshooting
• Note: the alarm in the “Alarm description” column is masked, if one alarm (at least) listed in the “Filtering rule” column (on the relevant row) is active.
Alarm description
Ethernet
Link Down
Demodulatio n function failure
Table 116: MPT-HC V2/MPT-MC/MPT-XP/9558HC alarm matrix (communication type)
MPT Main
Loss of
Radio Frame
Alarm displayed on
MCT
Probable cause
Filtering rule
1
Loss of Signal SFP traffic missing (if optical)
Demodulator
Failure
MPT Card Fail
Loss Of Frame Demodulation function failure
MPT Card Fail
Most probable cause
Bad connection to the
Ethernet generic device
Internal receive circuit failure
Action
Check the cable
Replace the MPT
1. Check/troubleshoot far end alarms
2. Replace alarmed MPT
Link
Identifier
Mismatch
High BER
(HBER)
Link Identifier
Mismatch
High BER
MPT Main Loss of
Radio Frame
Demodulation function failure
MPT Card Fail
Demodulation function failure
MPT Main Loss of
Radio Frame
Link Identifier
Mismatch
MPT Card Fail
Far end problems, RF path problems, or local circuit failures have caused BER to increase to the point that frames are being lost
Link identifier number provisioned is different from link identifier number provisioned at other end of hop
Bit Error Rate threshold
(10E-4) exceeded
Set numbers at both ends of hop to match
1. Verify RF path is clear, antenna is aligned, and no existing weather-related problems
2. Verify RSL is above
RCV threshold. If not - check upstream transmitter output/troubleshoot transmitter
468 MPR-e
Maintenance and trouble-clearing
Alarm
Table 116: MPT-HC V2/MPT-MC/MPT-XP/9558HC alarm matrix (communication type) description
Early
Warning
(EW)
MPT Main
Communicat ion Loop
Alarm displayed on
MCT
Probable cause
Filtering rule
1
Early Warning HBER
Demodulation function failure
MPT Main Loss of
Radio Frame
Link Identifier
Mismatch
MPT Card Fail
Loop Problem no
Most probable cause
10E-9 BER detected
Action
No action is required at this time. Monitor receive signal for increased degrading
Check the radio hop
ANSI_ATP
C_TimeOut
PPP fail
Coupling ethernet link down (*)
Atpc High
Power Timeout
PPP Failure
Loss Of Signal no no
Coupling Port SFP missing
Communication problem between the local MPT and the remote MPT for all the functionalities requiring a communication loop
(ATPC or ACM)
Alarm only managed in
ANSI mode and raised when Tx power level is at ATPC max level during 5 consecutive minutes
1) PPP RF channel not enabled in both stations of the radio link
2) Restart of remote
MPT on-going
(following a SW
Download operation)
3) Radio path broken
Communication between
MPT is failed
Check the radio hop
1) Verify PPP RF enabled
2) Wait MPT restart finalization
3) Verify the RF path
Check the cable
MPR-e 469
Troubleshooting
Alarm description
Coupling ethernet link error (*)
Inter MPT
Table 116: MPT-HC V2/MPT-MC/MPT-XP/9558HC alarm matrix (communication type)
communicati on problem
(*)
Alarm displayed on
MCT
Probable cause
Ethernet Signal
Degraded
Internal
Communicatio n Problem
(ICP)
Filtering rule
Coupling Ethernet link down
Coupling Port SFP missing no
1
Most probable cause
For the MPT Coupling optical port, the ratio between the number of received errored packets and the total number of received packets is above a given threshold.
Communication between the 2 MPT locally connected with ethernet cable is failed
Action
Check the cable
Replace the MPT
Legend:
• (*): only for MPT-HC V2/MPT-XP in XPIC configuration
• the alarm in the “Alarm description” column is masked, if one alarm (at least) listed in the “Filtering rule” column (on the relevant row) is active.
TCA on
TCA on
Radio Hop
(24 hours)
Table 117: MPT-HC V2/MPT-MC/MPT-XP/9558HC alarm matrix (quality of service type)
Alarm description
Radio Hop
(15 minutes)
Alarm displayed on MCT
Probable cause Type
Threshold
Crossed
Threshold
Crossed
Quality of
Service
Quality of
Service
Specific Problem
Radio Hop 15
Minutes BBE
Radio Hop 15
Minutes ES Counter
Radio Hop 15
Minutes SES
Counter
Radio Hop 24
Hours BBE
Radio Hop 24
Hours ES Counter
Radio Hop 24
Hours SES Counter
Filtering rule
no no
1
Most probable cause
Alarm threshold exceeded
Alarm threshold exceeded
470 MPR-e
Maintenance and trouble-clearing
Table 117: MPT-HC V2/MPT-MC/MPT-XP/9558HC alarm matrix (quality of service type)
Alarm description
UAT on
Radio Hop
Alarm displayed on MCT
Probable cause Type
Unavailable
Time
Quality of
Service
Specific Problem
Radio Hop 15
Minutes UAT
Radio Hop 24
Hours UAT
Filtering rule
no
1
Most probable cause
10 consecutive
SES (unavailable time period)
• Note: the alarm in the “Alarm description” column is masked, if one alarm (at least) listed in the “Filtering rule” column (on the relevant row) is active.
Relationship between the alarms on the MCT and SNMP traps
Alarm description
MPT Card fail
(Tx fail, Rx fail, Mod fail)
MPT Module
Card Fail (***)
Table 118: MPT SNMP traps (Equipment Type)
MCT
Probable cause Specific Problem
Replaceable
Unit Problem
(RUP)
Replaceable
Unit Problem
(RUP)
Tx BB LO Unlocked
RF LO Unlocked
Rx IF LO Unlocked
Rx BB LO Unlocked
Modem Tx
Synchronization
Tx Power
MPT Plug-in RI
Access Failure if XPIC plug-in add;
XPIC Plug-in Power
Supply Failure;
XPIC Inter-Modem
Calibration Failure
SNMP Traps
Probable cause
Replaceable Unit
Problem (RUP)
(opticsIMAlarmRepla ceableUnitProblem)
Replaceable Unit
Problem (RUP)
(opticsIMAlarmRepla ceableUnitProblem)
Managed object
Entry corresponding to faulty MPT in equipment table
Entry corresponding to faulty MPT module in equipment table
MPR-e 471
Troubleshooting
Alarm description
SFP traffic missing
Traffic SFP card fail
Incompatible
Shifter
Incompatible
Frequency
Incompatible
Modulation
Incompatible
Power
XPIC cable loss (*)
Coupling port
SFP missing
(*)
Replaceable
Unit Problem
(RUP)
Incompatible
Shifter
Incompatible
Frequency
Incompatible
Modulation
Incompatible
Power
Demodulator
XPIC Loss Of
Signal
Replaceable
Unit Missing
Table 118: MPT SNMP traps (Equipment Type)
MCT
Probable cause Specific Problem
Replaceable
Unit Missing
—
—
—
—
—
—
—
—
SNMP Traps
Probable cause
Replaceable Unit
Missing
(opticsIMAlarmRepla ceableUnitMissing)
Replaceable Unit
Problem (RUP)
(opticsIMAlarmRepla ceableUnitProblem)
Incompatible Shifter
(opticsIMAlarmIncom patibleShifter)
Incompatible
Frequency
(opticsIMAlarmIncom patibleFrequency)
Incompatible
Modulation Parameter
(opticsIMAlarmIncom patibleModulationPar am)
Incompatible PTx
(opticsIMAlarmIncom patiblePTX)
Dem XPIC Loss of
Signal
(opticsIMAlarmDem
XpicLOS)
Replaceable Unit
Missing
(opticsIMAlarmRepla ceableUnitMissing)
Managed object
Entry corresponding to missing SFP in equipment table
Entry corresponding to faulty SFP in equipment table
Entry corresponding to faulty radio port in ifTable
Entry corresponding to faulty radio port in ifTable
Entry corresponding to faulty radio port in ifTable
Entry corresponding to faulty radio port in ifTable
Entry corresponding to faulty MPT module in equipment table
Entry corresponding to faulty SFP on MPT1 coupling port in equipment table
472 MPR-e
Maintenance and trouble-clearing
Alarm description
Coupling port
SFP card fail
(*)
Table 118: MPT SNMP traps (Equipment Type)
MCT
Probable cause Specific Problem
Replaceable
Unit Problem
(RUP)
—
SNMP Traps
Probable cause
Replaceable Unit
Problem (RUP)
(opticsIMAlarmRepla ceableUnitProblem)
Managed object
Entry corresponding to faulty SFP on MPT1 coupling port in equipment table
Legend:
(***): Only for MPT-HC V2 and MPT-XP.
MPT Main Loss of
Radio Frame
Early Warning
(EW)
MPT Main
Communication
Loop
Table 119: MPT SNMP traps (communication type)
Alarm description MCT SNMP Traps
Probable cause Probable cause
Ethernet Link
Down
Demodulation function failure
Link Identifier
Mismatch
High BER (HBER)
Loss of Signal
Demodulator
Failure
Loss Of Frame
Link Identifier
Mismatch
High BER
Early Warning
Loop Problem
Loss Of Signal opticsIMAlarmLossOfSignal)
Dem Fail (opticsIMAlarmDemFail)
Loss Of Frame
(opticsIMAlarmLossOfFrame)
)
Link Identifier Mismatch
(opticsIMAlarmLinkIdentifierMismatch
High BER (opticsIMAlarmHighBER)
Early Warning
(opticsIMAlarmEarlyWarning)
Loop Problem
(opticsIMAlarmLoopProblem)
Managed object
Entry corresponding to faulty user ethernet port in ifTable
Entry corresponding to faulty MPT in equipment table
Entry corresponding to faulty radio port in ifTable
Entry corresponding to faulty MPT in equipment table
Entry corresponding to faulty MPT in equipment table
Entry corresponding to faulty MPT in equipment table
Entry corresponding to faulty radio port in ifTable
MPR-e 473
Troubleshooting
Table 119: MPT SNMP traps (communication type)
Alarm description MCT SNMP Traps
Probable cause Probable cause
ANSI_ATPC_Tim eOut
PPP fail
Coupling ethernet link down (*)
Coupling ethernet link error (*)
Inter MPT communication problem (*)
Atpc High Power
Timeout
PPP Failure
Loss Of Signal
Ethernet Signal
Degraded
Internal
Communication
Problem (ICP)
Alarm ATPC Timeout
(opticsIMAlarmATPCTimeout)
PPP Fail (opticsIMAlarmPPPFail)
Loss Of Signal opticsIMAlarmLossOfSignal)
Eth Signal Degraded
(opticsIMAlarmEthSignalDegraded)
Internal Communication Problem
(opticsIMAlarmInternalCommunication
Problem)
Managed object
Entry corresponding to faulty radio port in ifTable
Entry corresponding to faulty radio port in ifTable
Entry corresponding to faulty SFP on MPT1 coupling port in equipment table
Entry corresponding to faulty SFP on MPT1 coupling port in equipment table
Entry corresponding to the MPT in equipment table
Legend:
• (*): only for MPT-HC V2/MPT-XP in XPIC configuration
474 MPR-e
Maintenance and trouble-clearing
Alarm description
TCA on
Radio Hop
(15 minutes)
TCA on
Radio Hop
(24 hours)
UAT on
Radio Hop
MCT
Probable cause
Threshold
Crossed
Unavailable
Time
Table 120: MPT SNMP traps (quality of service type)
Specific Problem
SNMP Traps
Probable cause
Radio Hop 15 Minutes BBE
Radio Hop 15 Minutes ES
Counter
Radio Hop 15 Minutes SES
Counter
Radio Hop 24 Hours BBE
Radio Hop 24 Hours ES Counter
Radio Hop 24 Hours SES Counter
Radio Hop 15 Minutes UAT
Radio Hop 24 Hours UAT
Threshold Crossed
(opticsIMAlarmTCA)
Threshold Crossed
(opticsIMAlarmTCA)
UnavailableTime
(opticsIMAlarmUnav ailableTime)
UnavailableTime
(opticsIMAlarmUnav ailableTime)
Managed object
Entry corresponding to the faulty radio port ifIndex and the granularity index (=1 for 15mn) in opticsIMPdhFrameH opCurrentDataTable.
Entry corresponding to the faulty radio port ifIndex and the granularity index (= 2 for 24h) in opticsIMPdhFrameH opCurrentDataTable.
Entry corresponding to the faulty radio port ifIndex and the granularity index (=1 for 15mn) in opticsIMPdhFrameH opCurrentDataTable.
Entry corresponding to the faulty radio port ifIndex and the granularity index (= 2 for 24h) in opticsIMPdhFrameH opCurrentDataTable.
Troubleshooting path problems
A path-related problem, with the exception of interference, is characterized by traffic being similarly affected in both directions. Generally, if you are experiencing only a one-way problem, it is not a path problem.
MPR-e 475
Troubleshooting
Note: A path extends from MPR-e antenna port to MPR-e antenna port.
• Normally a path problem is signalled by a reduced RSL, and depending on its severity, a high BER.
• Only in worst case situations, such as an antenna knocked out of alignment, will a path fail completely, and stay that way.
• For weather-related problems, such as rain or ducting, the path problem will disappear as the weather returns to normal.
Path problems on a commissioned link
A path problem on an existing link, one that has been operating satisfactorily may be caused by one of the following:
•
Weather-related path degradation
If BER alarms are fleeting/not permanent and RSL returns to its normal, commissioned level after the alarm is cleared, rain, diffraction, or multipath fading is indicated. Rain fade is the likely cause of fade for links 13 GHz and higher.
Diffraction and multipath/ducting for links 11 GHz and lower. If these alarms are persistent, there could be a problem with the link design or original installation.
•
Changed antenna alignment or antenna feed problem
If RSLs do not return to commissioned levels after a period of exceptionally strong winds, suspect antenna alignment. Also, check the antenna for physical damage, such as may occur with ice-fall. For a remote-mounted MPR-e, check its antenna feeder.
•
New path obstruction
Where all other parameters check as normal, and the path has potential for it to be obstructed by construction works, view/survey the path for possible new obstructions.
•
Interference from other signal sources
Interference usually affects traffic in just one direction. Unlike other path problems,
RSL is not affected. If suspected, check for new link installations at, or in the same geographical area, as the affected site. Ultimately, a spectrum analyzer may have to be used to confirm interference, which is not an easy task given the need to connect directly to the antenna port, after removing the MPR-e.
476 MPR-e
Maintenance and trouble-clearing
Path problems on a new link
For a new link, potential problems can extend to also include:
•
Incorrect antenna alignment
One or both antennas incorrectly aligned. Refer to Antenna alignment procedure.
•
Mismatching antenna polarizations
Given a typical polarization discrimination of 30 dB, for most links it is not possible to capture a signal to begin the antenna alignment process.
•
Incorrect path calculations
If the RSLs are too low or too high, antenna alignment is correct, and Tx power settings are correct, check the path calculations used to determine the link performance. A good calculation match is ± 2 dB. Disagreements in excess of 3 dB should be investigated.
•
Reflections
Reflection (path cancellation) problems may not have been picked up at the path planning stage, particularly if the survey was a simple line-of-sight. If suspected, resurvey the path.
Equipment removal and replacement
Warning: Never install, change or remove an unit without first connecting to the shelf with an ESD grounding cable. Failure to do so may cause ESD damage to the cards.
MPT-HC V2/MPT-XP/9558HC removal and replacement
Disconnect the cables and connect them to the spare MPT-HC V2/MPT-XP/9558HC.
Note: The MPT-HC V2 can also be used to replace the MPT-HC V1. The 23 GHz MPT-HC
V2 is a Tx High Power version vs. MPT-HC V1. Take in account it when MPT-HC V2 is used as spare of MPT-HC V1.
MPR-e 477
Cleaning
Replacement of an MPT-HC V2/MPT-XP in XPIC configuration
To replace an MPT-HC V2/MPT-XP in XPIC configuration it is mandatory to follow the following procedure:
1. Power off the MPT-HC V2/MPT-XP
2. Disconnect the XPIC cable
3. Disconnect the RPS cable
4. Uninstall the failed MPT-HC V2/MPT-XP
5. Install the spare MPT-HC V2/MPT-XP
6. Connect the RPS cable
7. Connect the XPIC cable
8. Power on the MPT-HC V2/MPT-XP
MPT-MC removal and replacement
Disconnect the cables and connect them to the spare MPT-MC.
Cleaning
Warning: Do not use acid, alcohol, or brushes to clean the equipment because damage to the silk-screen labeling and antistatic coating can result. Cleaning should be confined to the removal of dust and dirt using a damp cloth.
Cleaning should normally be confined to the removal of dust and dirt using a soft bristled
(natural fiber) brush and a low velocity blower (such as a vacuum cleaner with a plastic blower nozzle). Do not use acid or synthetic bristled brushes to clean cards that contain electrostatic-sensitive components.
478 MPR-e
Line–up and commissioning
This chapter details all phases necessary for the equipment line–up and commissioning.
Table 121: Phases of line-up and commissioning
Safety–EMC–EMF–ESD norms and cautions to avoid equipment damage
Summary of the line–up, commissioning, and acceptance phases
Commissioning of STATION A – phase 1 (Turn up)
Commissioning of STATION B – phase 1 (Turn up)
Fine antenna alignment and preliminary checks – Stations A & B
End of commissioning phase 1 (turn up) in STATION A
Commissioning station A – phase 2 (acceptance test)
Commissioning station B – phase 2 (acceptance test)
Annex A: fine antenna alignment
Introduction
General
This chapter details all phases necessary for the equipment line–up, commissioning, and acceptance, providing the user with the information needed to connect, power on, and perform a minimum turn–up of a radio link comprising two MPR-e.
MPR-e 479
Introduction
Note: If the radio link consists of one MPR-e standalone and one MPR-e connected to an
MSS-4/MSS-8/MSS-1, see the relevant User Manual to commission the link.
It is assumed that, at both premises (Station A and Station B), the mechanical installation and cabling of the INDOOR and OUTDOOR sections is completed, the antennas are installed and pre–positioned, and the Indoor/Outdoor cables have been properly connected.
Any information needed to complete the above mentioned operations are out of the scope of this chapter.
For this purpose refer to the Installation section.
All the cables and measurement kits as described in
INSTRUMENT
Table 122: Test and commissioning instruments
QTY
1
CHARACTERISTICS
MCTTCO 5.x
Laptop computer running the NE software
(For the laptop characteristics, see PC characteristics )
Link Service kit cable (for MPR-e antenna alignment)
2 Ethernet Data Analyzers
Multi–meter
Cable Tester
TRS
1
TDS
2
1
1
1
1
1 for Ethernet Data channel functionality tests
Voltmeter AC and DC – Loop tester
For RJ45, Ethernet, Optical fiber etc.
Test Result Sheet, available as separate document
Test Data Sheet, available as separate document
1.
MPR-E
2.
MPR-A
The Alcatel–Lucent Software package must be installed in the PC used as the MCT and the same software version must be present as commit version in the two Network Elements.
An FTP server must be installed in the PC.
Before proceeding with line–up and commissioning, ensure that you have the equipment and accessories required for that purpose.
480 MPR-e
Line–up and commissioning
Safety–EMC–EMF–ESD norms and cautions to avoid equipment damage
Warning: to make sure of the continuity and avoid short circuit, all cables / connectors connections such as RJ45, Coaxial, Ethernet, or Optical Fiber made in the field have to be verified and checked with Cable tester. The waterproofness must be also checked.
Verify that you have read the
Safety, EMC, EMF, ESD norms, equipment labeling, standards and compliance
chapter: it describes the operations and precautions to be observed to safeguard operating personnel during the working phases, and to guarantee equipment safety.
Summary of the line–up, commissioning, and acceptance phases
The commissioning operations described in this document are for a radio link between
Station A and Station B.
The commissioning operations described in this document are for a radio link between a
Station A and a Station B.
If the network includes supervision, station A is the one located between the supervisory
station and station B (see Figure 393
). Installation and commissioning begin at station A.
Figure 393: Relative positions of stations A and B
MPR-e 481
Introduction
Warning: at the beginning of this procedure, in an MPR-e standalone configuration, the
“local IP address” and “Ethernet IP address” of both the NE 9500 MPR stations areof each
MPR-e station is still set to default value 10.0.1.2 (as delivered from Alcatel–Lucent factory).
Consequently, their physical connection to the TMN network must be completed after having changed such addresses to correct values.
The commissioning procedure is summarized as follows:
1. Turn up (phase 1)
→ Visual inspection and NE configuration.
a. Station A, roughly point the antenna towards station B (if not done in the
Hardware Installation procedure) b. Commission station A (phase 1) c. Commission station B (phase 1)
Figure 394: Point antenna toward station B
→ Fine antenna alignment and preliminary checks – Stations A & B a. Station B, fine align the antenna towards station A, and preliminary checks b. Station A, fine align the antenna towards station B, and preliminary checks
Figure 395: Fine align the antenna toward station A
2. Site acceptance tests (phase 2)
482 MPR-e
Line–up and commissioning
→ Station A, perform all the commissioning checks and tests – Report the results in the TRDS.
Figure 396: Station A commissioning checks and tests
→ Station B, perform all the commissioning checks and tests – Report the results in the TRS.
Figure 397: Station B commissioning checks and tests
MCT connection
Two options are possible for MPR-e standalone:
• MCT can be connected to the Ethernet generic device, as shown in
MPR-e standalone: Installation & interconnection overview . See the pre-requisites in
Ethernet generic device prerequisites .
• The MCT can be connected directly to the MPR-e (or to the Power Injector). The PC must have a 10/100/1000BaseT Ethernet network card and the VLAN tagging feature.
When in Single NE mode with 7705 SAR, the MCT Launcher must be used as shown in
MPR-e in Single NE mode with 7705 SAR: installation & interconnection overview . The IP
address to be used for connection is any reachable IPv4 address of the 7705 SAR. Connection is always possible as long as the 7705 SAR is reachable.
MPR-e 483
Introduction
How to access the remote NE
Figure 398: Accessing the remote NE
484
Configuration example of NE in STATION A
• NE Local IP address: 172.168.60.1
• NE TMN In-band IP address: 192.168.50.2
Configuration example of NE in STATION B
• NE Local IP address: 172.168.60.2.
Note: The local and remote NE IP addresses must be in the same subnet.
The PC, as shown in Figure 398
, is connected to the equipment in Station A. The MCT can also access the equipment in Station B.
How to configure the PC
• Assign an IP address to the PC that is in the same subnet as the TMN In-band interface. Perform one of the following:
→ In in the Configuration > Networking > Static Routing menu, add the Static route " 0.0.0.0 0.0.0.0 192.168.50.2" (IP address of the TMN In-band working as Gateway).
→ In the IP configuration of the Ethernet Interface, set the Default Gateway to
192.168.50.2 (NE A TMN In-band IP address).
Note: The PC must add a VLAN tag in the frames sent to the TMN In-band, if connected directly to the NE A. The VLAN ID must be the same as the one configured in the NE.
MPR-e
Line–up and commissioning
Two options are available:
• Option 1: with OSPF
• Option 2: without OSPF
Option 1: with OSPF
How to configure the MPT in Station A
• Enable the "TMN RF" and associate an OSPF Area to the TMN-RF in the
Configuration > Networking > Network interfaces menu
• Associate an OSPF Area to the TMN In-band interface in the Configuration >
Networking > Network interfaces menu.
How to configure the MPT in Station B
• Enable the "TMN RF" and associate an OSPF Area to the TMN-RF in the
Configuration > Networking > Network interfaces menu. The OSPF area in MPRe standalone in Stations A and B must be the same.
Option 2: without OSPF
How to configure the MPT in Station A
• Enable the "TMN RF" in the Configuration > Networking > Network interfaces menu.
How to configure the MPT in Station B
• Enable the "TMN RF" in the Configuration > Networking > Network interfaces menu.
• Perform one of the following:
→ Add the Static route "Default 0.0.0.0 0.0.0.0 Link on radio side" in the
Configuration > Networking > Static Routing menu.
MPR-e 485
Introduction
→ Or Add a static route to Network 192.168.50.0 255.255.255.0 Link on radio side.
→ Or Add a static route to Host 192.168.50.x (PC IP address) 255.255.255.255
Link on radio side.
How to access the remote MPR-e in Single NE mode with
7705 SAR
Figure 399: Accessing the remote MPR-e in Single NE mode with 7705 SAR
486
Configuration example of MPR-e in STATION A
• SAR system IP: 172.168.60.1/32
• CSM Mgmt port IP: 192.168.50.2/30
Configuration example of MPR-e in STATION B
• SAR system IP: 172.168.60.2/32
The PC, as shown in Figure 399
, is connected to the equipment in Station A. The MCT can also access the equipment in Station B.
How to configure the PC
1. Assign an IP address to the PC that is in the same subnet as the 7705 SAR CSM
Mgmt interface.
2. Perform one of the following:
MPR-e
Line–up and commissioning
→ In in the Configuration > Networking > Static Routing menu, add the Static route " 0.0.0.0 0.0.0.0 192.168.50.2" (IP address of the 7705 SAR CSM Mgmt interface as Gateway).
→ In the IP configuration of the Ethernet Interface, set the Default Gateway to
192.168.50.2 (IP address of SAR CSM Mgmt interface as Gateway)
Commissioning of STATION A – phase 1 (Turn up)
Caution: Where necessary, switch OFF the power supply before disconnecting the earth connection.
Turn–on preliminary operations
Caution: All the following operations must be performed with the power off.
Check the following:
• The antenna of station A (or B) is pointed towards station B (or A) the best as possible
(use compass if necessary).
• The hardware configuration of the equipment corresponds to the expected one.
• Make visual inspection for equipment installation and cabling:
→ Power Injector allocation according to the station lay–out
→ Ground connections
→ Power supply voltage present with the correct polarity at the Power Injector power supply input for MPT-HC/MPT-MC
→ Ethernet connections between the Ethernet generic device and Power Injector for
MPT-HC/MPT-MC
→ Indoor-Outdoor cables ground kit connections
→ MPR-e ground connections (in the case of a non–integrated antenna, the antenna and the MPR-e must be ground connected)
→ MPR-e cables connectors waterproofing.
MPR-e 487
Commissioning of STATION A – phase 1 (Turn up)
Powering up the MPT
Proceed as follows for MPR-e standalone:
Option 1
1. Connect the PC locally to the Traffic Ethernet port of the MPT.
2. Switch on the MPT.
3. Start-up the MCT and wait for the Welcome screen.
4. Insert the "TMN in Band default address".
5. Start supervision on the local Network Element.
6. Configure the NE as explained in the Provisioning chapter.
Option 2
1. Switch on the Ethernet generic device.
2. Connect locally the MCT to the Ethernet generic device of the local station and perform the NE login.
3. Make a local connection through the Ethernet cable, between the Ethernet port of the
PC and the FE interface on the Ethernet generic device.
4. Power on the PC and wait for its start-up.
5. Start-up the MCT and wait for the Welcome screen.
6. Insert the "TMN in Band default address".
7. Start supervision on the local Network Element.
8. Configure the NE as explained in the Provisioning chapter.
Proceed as follows for MPR-e in Single NE mode with 7705 SAR:
1. Connect the PC locally to the 7705 SAR Core-E Mgmt Port.
2. Switch on the 7705 SAR and MPR-e if powered separately.
3. Start-up the MCT Launcher and wait for the Welcome screen.
4. Enter the Core-E Mgmt port IP address.
5. Start supervision on the 7705 SAR.
6. Configure the NE as explained in the Provisioning chapter.
488 MPR-e
Line–up and commissioning
Commissioning of STATION B – phase 1 (Turn up)
To commission Station B, perform (at Station B premises) the same operations carried on at
Station A – Phase 1.
Fine antenna alignment and preliminary checks –
Stations A & B
Fine antenna alignment
When Station A and Station B are fully configured and operational, and assuming that the antenna in station A (or B) has been previously correctly pointed toward the antenna in station
B (or A), you should receive some field from station B (or A).
Note: Verify that the ATPC is disabled.
Now, proceed to a fine tuning of the antenna to improve as much as possible the received level, in both Station A (at Station A premises) and Station B (at Station B premises). To perform the fine antenna alignment see
Annex A: fine antenna alignment
.
Preliminary checks
At first on Station A (at Station A premises), then on Station B (at Station B premises), log in the NE and perform following checks using the MCT:
Table 123: MCT checks
Transmitter power output check
MPR-e 489
Fine antenna alignment and preliminary checks – Stations A & B
Verify MPT alarm status
Purpose: To verify that no abnormal communication alarm between the Generic L2/L3
Indoor Equipment and MPT.
Required Instruments: PC with Craft Terminal software
Procedure:
1. Connect the MCT to the Ethernet generic device.
2. In the Alarms menu in the MCT: a. Verify in the alarms list that there is no communication failure b. Verify in the alarms list that there is no Tx failure
Transmitter power output check
Purpose: To verify the MPR-e transmitted power output using the MCT.
Required Instruments: PC with Craft Terminal software
Procedure:
1. Connect the MCT to the Ethernet generic device
2. In the Monitoring > Power Measurement menu in the MCT: a. In the Configuration > Radio menu, verify that ATPC is Disabled.
If required, change the ATPC status to disable in the ATPC field.
b. Verify that Tx Power value complies with the suitable value already set.
If required, change the Tx Power in the Configuration > Radio menu
Received power measurement
Purpose: To verify the received power to detect any interference using the MCT
Required Instruments: PC with Craft Terminal software
Procedure:
1. Connect the MCT to the Ethernet generic device
2. In the Monitoring > Power Measurement menu in the MCT:
490 MPR-e
Line–up and commissioning a. In the Refresh period (sec) field, enter the suitable measurement polling time
(default = 5 sec)
3. Press “Start” to prompt a graphic monitoring view of the transmitted and received levels.
a. Verify in the hop calculation (plant documentation) that the calculated received level has been reached.
b. Verify that there are no interferences.
End of commissioning phase 1 (turn up) in STATION
A
• In Station A, proceed to a final fine alignment of the antenna toward the antenna of
Station B. To perform the fine antenna alignment, see
Annex A: fine antenna alignment .
• In Station A, proceed to the remote NE (station B) acquisition (by opening a second
MCT session) in order to verify in both the stations:
→ Received level complies with hop calculation
→ No alarm showing
Commissioning station A – phase 2 (acceptance test)
Commissioning phase 2 is a site acceptance test procedure made up of the required tests to ensure that the equipment is fully operational.
This phase describes the procedure to check and, if necessary, to change the different configuration parameters set during Provisioning along with various tests.
Most of the tests and checks results have to be recorded in the TRDS (Test Results Data
Sheet). Operator will be invited to do so each time it is required by the following sentence:
“Report… in the TRDS.”
Note: The lettered titles in [ a ) , b ) , etc.] correspond to the page’s heading titles of the
TRS/TDS document.
MPR-e 491
Commissioning station A – phase 2 (acceptance test)
Table 124: Commissioning phase 2
Test Report in
TRDS
Installation and cabling visual inspection
Indoor system installation and cabling visual inspection
Outdoor system installation and cabling visual inspection
Check software release (valid for MPR-e standalone only)
Check/set mode (fixed or adaptive modulation), channel spacing, modulation
Yes
Yes
Yes
Yes
Check/set Tx/Rx spacing, transmission and reception frequencies
Yes
Check/set Tx power (ATPC Off) or Tx range and Rx threshold (ATPC on)
Yes
Check/set the XPIC (only with MPT-HC V2/MPT-XP, if the co-channel
XPIC configuration has to be used)
Yes
Check/set Link identifier configuration (optional)
Tx and Rx power measurement (with MCT)
Yes
Yes
Yes
Check/set the local NE IP address (valid for MPR-e standalone only)
Check/set the TMN in-band configuration
Check/set OSPF configuration (valid for MPR-e standalone only)
Check/set IP static routing configuration (valid for MPR-e standalone only)
Data/time settings (valid for MPR-e standalone only)
Ethernet traffic hop stability test with MPR-e standalone
Yes
Yes
Yes
Yes
Yes
Yes
492 MPR-e
Line–up and commissioning
Installation and cabling visual inspection
Indoor system installation and cabling visual inspection
See and fill the indoor inspection check list in the TRDS.
Outdoor system installation and cabling visual inspection
See and fill the outdoor inspection check list in the TRDS.
System configuration
Purpose: Verify the configuration of the Local Station using the MCT.
Required Instruments: PC with Craft Terminal software
Procedure: Connect the MCT/MCT Launcher to the Ethernet generic device or the
7705 SAR.
Check software release (valid for MPR-e standalone only)
In the MCT, open the Commissioning > Software Download > Tab-panel Software Package
Versions menu.
Check the Software release.
Report in the TRDS.
Check/set mode (fixed or adaptive modulation), channel spacing, modulation
In the MCT, open the Commissioning > Configuration > Radio menu.
If required, change any parameter.
MPR-e 493
Commissioning station A – phase 2 (acceptance test)
Report in the TRDS.
Check/set Tx/Rx spacing, transmission and reception frequencies
In the MCT, open the Commissioning > Configuration > Radio menu.
Report the Shifter, Tx and the Rx frequencies in the TRDS.
If required, change the Tx frequency. Rx Freq. will be automatically adjusted.
Check/set Tx power (ATPC Off) or Tx range and Rx threshold (ATPC on)
In the MCT, open the Commissioning > Configuration > Radio menu.
• If the ATPC is Disabled, report the Disabled status, Tx nominal power and Tx power setting in the TRDS
• If the ATPC is Enabled, report the ATPC “Enabled” status, ATPC Range and ATPC
RX Threshold setting in the TRDS.
If required, change ATPC Mode or ATPC Range or ATPC Rx Threshold then click on the
Apply button.
Check/set the XPIC (only with MPT-HC V2/MPT-XP, if the cochannel XPIC configuration has to be used)
In the MCT, open the Commissioning > Configuration > Radio menu.
Report the XPIC Configuration in the TRDS.
Check/set Link identifier configuration (optional)
In the MCT, open the Commissioning > Configuration > Advanced Radio menu.
If necessary, change any parameter.
Report the Link Identifier status (Enabled or Disabled), and, if Enabled, the “Expected” and
“Sent” values.
494 MPR-e
Line–up and commissioning
Check/set the synchronization
In the MCT, open the Commissioning > Configuration >User port menu.
Check/set all the parameters regarding the synchronization (valid for MPR-e standalone only).
Report in the TRDS.
Tx and Rx power measurement (with MCT)
Purpose: To verify the Transmitted (PTx) and Received (PRx) power using the MCT.
Required Instruments: PC with Craft Terminal software
Procedure:
1. Connect the MCT to the Ethernet generic device
2. In the MCT Monitoring > Power Measurements menu: a. In the Refresh Period (sec) field, enter the measurement polling time and click on Start to prompt a graphic monitoring view of the transmitted and received levels.
Report the Current Tx Local End (PTx) and the current Rx Local End (PRx) in the TRDS.
Check/set the 1+1 HSB (only with MPT-HC V2/MPT-XP connected to 7705 SAR-8/18)
In the MCT, open the Commissioning > Configuration > Radio menu.
Report the 1+1 HSB Configuration in the TRDS.
Ethernet traffic QoS
In the MCT, open the Commissioning > Configuration > Ethernet Traffic QoS menu.
Check and, if necessary, change the parameters.
Report in the TRDS.
MPR-e 495
Commissioning station A – phase 2 (acceptance test)
NE configuration
Check/set the local NE IP address (valid for MPR-e standalone only)
In the MCT, open the Commissioning > Configuration > Networking > Network Interfaces menu.
Report the local IP Address in the TRDS.
Check/set the TMN in-band configuration
In the MCT, open the Commissioning > Configuration > Networking > Network Interfaces
> TMN In-band parameters menu.
Valid for MPR-e standalone only.
Report the IP Address and IP Mask in the TRDS.
Check/set OSPF configuration (valid for MPR-e standalone only)
In the MCT, open the Configuration > Networking > Network Interfaces > OSPF
Management menu.
Report the OSPF management in the TRDS.
Check/set IP static routing configuration (valid for MPR-e standalone only)
In the MCT, open the Commissioning > Configuration > Networking > Static Routing menu.
Report the IP Address, IP Mask and Default gateway IP Address or interface type into the
TRDS.
496 MPR-e
Line–up and commissioning
Data/time settings (valid for MPR-e standalone only)
In the MCT, open the Commissioning > Configuration > Data/Time menu.
Enter the time settings.
Report in the TRDS.
Ethernet traffic hop stability test with MPR-e standalone
Purpose: To verify the quality of point to point Ethernet traffic
Required Instruments: 2 Ethernet Data Analyzers
Procedure:
1. Disconnect the Ethernet cable from the Ethernet generic device and set up the test bench with 2 Ethernet Data Analyzers as shown in
Figure 401 for MPT-HC V2/MPT-XP/9558HC. On both stations connect the Data
analyzer.
2. Configure the Ethernet Data Analyzer in order to generate continuos traffic and set the data rate to half the radio capacity and with packet size of 1518 bytes.
3. Perform the stability test for 2 hours.
4. Compare the number of Tx and Rx Frames on the Pattern A: the number of frames must be equal in normal propagation conditions (out of fading period).
Report the two-hour error-free Ethernet Stability Test result in the TRDS.
5. Disconnect the Ethernet Data Analyzer and re-connect the Ethernet cable to the
Ethernet generic device.
6. Using the MCT, ping the MPR-e in the local station and in the remote station.
MPR-e 497
Commissioning station A – phase 2 (acceptance test)
Figure 400: Ethernet traffic hop stability test with MPT-MC/MPT-HC V2/MPT-XP/
9558HC
Figure 401: Ethernet traffic hop stability test with MPT-HC V2/MPT-XP/9558HC
Ethernet traffic verification test for MPR-e in Single NE mode with 7705 SAR
Purpose: To verify the connectivity between the MPR-e and the 7705 SAR at the two end points.
Required Instruments: PC with Craft Terminal software and serial interface
Procedure
Prerequisite: the 7705 SAR has been configured.
1. Connect the PC to the 7705 SAR console.
2. Login into the 7705 SAR system.
498 MPR-e
Line–up and commissioning
3. Issue a ping command with the 7705 SAR system IP address at the other radio end as the target IP address.
Commissioning station B – phase 2 (acceptance test)
Repeat in Station B all the tests performed in Station A except the Hop Stability Test. The
Hop Stability Test has to be performed only one time for the full hop.
Fill a second Test Result Sheet/Test Data Sheet for Station B
END OF COMMISSIONING ACCEPTANCE TEST
Final operations
Complete the commissioning of each NE, creating the NE operator profiles and saving its data.
Annex A: fine antenna alignment
Safety requirements for workers on antenna pole, and microwave radiations (EMF norms)
Caution: When operating on the antenna pole, strictly follow cautions.
Do not stand on the antenna axis and be aware of the compliance boundaries.
Antenna pre–pointing should have been done during equipment hardware installation.
This annex explains how to carry out the antenna fine alignment.
To monitor the received level during alignment in the local station:
• use the MPR-e Rx power monitoring in addition to a voltmeter,
• or, after having logged in the NE, use the Craft Terminal received power measurement facility
MPR-e 499
Annex A: fine antenna alignment
Alignment procedure using the MPR-e Rx power monitoring
Notes:
• the radio link must be up and the ATPC disabled
• in general, fine alignment should be done only on one station of the radio link
Procedure
1. Connect a voltmeter to the MPR-e (by using the Light Service kit cable for the MPT)
2. Proceed with Vertical alignment, then with Horizontal alignment
3. In configurations with two antennas, repeat the procedure for the second antenna.
Note: Procedures for Vertical and Horizontal alignment depend on the type of integrated pole mounting employed.
500 MPR-e
Abbreviations
MPR-e
ABBREVIATION
ACM
ADM
AIS
ALS
ANSI
APS
AS
ASAP
ATPC
AVC
BER
BR & SW
Browser
CCDP
CLNP
CDCC
CD-ROM
Table 125: Abbreviations
MEANING
Adaptive Coding Modulation
Add Drop Multiplexer
Alarm Indication Signal
Automatic Laser Shutdown
American National Standards Association, for the North American market
Automatic Protection Switching
Alarm Surveillance
Alarm Severity Assignment Profile
Automatic Transmit Power Control
Attribute Value Change
Bit Error Rate
Bridge & Switch
Application which allows to browse all RM-MIB objects
Co-Channel Dual Polarization
Connection Less Network Protocol
Data Communication Channel
Compact Disc Read Only Memory
501
502
ABBREVIATION
CES
CI
CLA
CRU
CTP
CT
C-VLAN
DCC
DCI
DCN
DDF
DS
ECC
EFC
EML
EML domain
EOW
EPS
EPU
EMS
Table 125: Abbreviations
MEANING
Circuit Emulation Service
Communication Infrastructure
Common Loss Alarm
Clock Reference Unit
Connection Termination Point
Craft Terminal
Customer VLAN
Data Communication Channel
Drop & Continue Interconnection
Data Communications Network
Digital Distribution Frame
Degraded Signal
Embedded Communication Channels
Ethernet Flow Control
Element Management Layer
A set of NEs that are maintained by the same EML-OS.
Engineering Order Wire
Equipment Protection Switching
Eps Protection Unit
Event Management Services
MPR-e
HSB
HTML
ICP
MPR-e
IWF
Abbreviations
FCM
FCS
FD
FE
FLS
FM
Gbit/s
GE
GFP
GNE
HBER
Table 125: Abbreviations
ABBREVIATION
ET
MEANING
Elementary Topology. It is a grouping of some nodes connected according to specific rules. A typical ET is a ring.
ETH ETHernet outside North America
Fixed Coding Modulation
Frame Check Sequence
Frequency Diversity
Fast Ethernet
Frame Loss Second
FM Fault Management
Gigabits per second
Gigabit Ethernet
Generic Frame Protocol
Gateway Network Element
High Bit Error Ratio
Hot Stand-By
Hyper Text Markup Language
Internal Communication Problem
Inter-Working Function
503
504
MAU
Mbit/s
MCT
MEF
MIB
MPR
MPR-A
MPR-E
MPT-HC
MPT-HC V2
MPT-MC
MPT-XP
LAN
LAPD
LBER
LCT
LDPC
LOF
LOS
MAC
ABBREVIATION
IEEE
IM
JUSM
Kbit/s
LAG
Table 125: Abbreviations
MEANING
Institute of Electrical and Electronics Engineers
Information Manager
Java User Service Manager
Kilobits per second
Link Aggregation Group
Local Area Network
Link Access Procedure on D-channel
Low Bit Error Ratio
Local Craft Terminal
Low Density Parity Check
Loss Of Frame
Loss Of Signal
Medium Access Control
Medium Attachment Unit
Megabits per seconds
Microwave Craft Terminal
Metro Ethernet Forum
Management Information Base
Microwave Packet Radio
Microwave Packet Radio for ANSI
Microwave Packet Radio for ETSI
Microwave Packet Transport - High Capacity
Microwave Packet Transport - High Capacity Version 2
Microwave Packet Transport - Medium Capacity
Microwave Packet Transport - High Capacity (very high power version of MPT-HC V2)
MPR-e
MPR-e
Table 125: Abbreviations
Node
NSA
NTP
OC
OCN
ODN
ODU
OFS
ABBREVIATION
MSS
MSS-1c
NE
NEC
NMS
MEANING
Microwave Service Switch
Microwave Service Switch Compact
Network Element
Network Element Clock
Network Management system
It is the view of the NE at NML level
Not Service Affecting
Network Time Protocol
ODU Controller
Object Creation Notification
Object deletion Notification
OutDoor Unit
Out of Frame Seconds
OH OverHead
OMT Orthogonal Mode Transducer
OS
PDH
Operation System
Plesiochronous Digital Hierarchy
PFoE
PM
PNU
Port
Power Feed over Ethernet
Performance Monitoring
Packet Node Unit
Physical Interface of a Node. A port can be SDH or PDH.
PI
PPI
PRBS
PSU
Physical Interface
PDH Physical Interface
Pseudo Random Bit Sequence
Power Supply Unit
Abbreviations
505
506
ABBREVIATION
RACS
RDI
SCU
SD
SDH
SES
SF
SFP
SONET
SPDH
STM
S-VLAN
TCA
RPG
RPU
RPS
RPPI
RTP
SA
SCG
TDF
Table 125: Abbreviations
MEANING
Received Automatic Control Status
Remote Defect Indication
Rps Protection Group
Rps Protection Unit
Radio Protection Switching
Radio Plesiochronous Physical Interface
Real Time Protocol
Site Aggregator
Service Channel Protection Group
Service Channel Protection Unit
Signal Degrade
Synchronous Digital Hierarchy
Severely Errored Second
Signal Failure
Small Form-factor Pluggable
Synchronous Optical Network
Super PDH
Synchronous Transport Module
Service VLAN
Threshold Crossing Alarm
Total Discarded Frames
MPR-e
MPR-e
TTP
USM
UPA
URU
VLAN
WTR
XCO
XPD
XPIC
ABBREVIATION
TMN
TPS
TPG
TRCF
TRCO
TRSEF
TRsp
TRU
Table 125: Abbreviations
MEANING
Telecommunications Management Network
Tx Protection Switching
Tps Protection Group
Total Received Correct Frames
Total Received Correct Octets
Total Received Service Errored Frames
Tx Rx spacing
Top Rack Unit
Trail Termination Point
User Service Manager
Unavailable path alarm
Underlying Resource Unavailable
Virtual Local Area Network
Wait Time to Restore
Cross-connection
Cross Polar Discrimination
Cross Polar Interference Canceller
Abbreviations
507
508 MPR-e
Customer documentation and product support
Customer documentation
http://www.alcatel-lucent.com/myaccess
Product manuals and documentation updates are available at alcatel-lucent.com. If you are a new user and require access to this service, please contact your Alcatel-Lucent sales representative.
Technical support
http://support.alcatel-lucent.com
Documentation feedback
© 2013 Alcatel-Lucent. All rights reserved.
3DB 19901 EDAA Edition 01
Download
Advertisement
Key features
Flexible waveguide
Variety of lengths and frequencies
High performance
Adaptive Modulation and Coding
Diversity reception
Automatic power control
Frequently asked questions
The Flextwist waveguide is a flexible waveguide that is used to connect the MPT-HC V2/MPT-XP output flange to the external antenna. It is available in a variety of lengths and frequencies to meet your specific needs.
The Flextwist waveguide is flexible and easy to install. It can be used in a variety of applications, including point-to-point links, point-to-multipoint links, and wireless backhaul.
The MPT-HC V2 and MPT-XP are both high-performance transceivers. However, the MPT-HC V2 is designed for use in the 6 GHz band, while the MPT-XP is designed for use in the 7-8 GHz band. The MPT-HC V2 is also available with an integrated antenna, while the MPT-XP is not.
The MPT-HC V2 and MPT-XP transceivers are equipped with advanced features such as Adaptive Modulation and Coding (AMC), diversity reception, and automatic power control.