Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
MAINTENANCE TRAINING OBJECTIVES
TM1800 Truck Mounted Deicer
Upon completion of this training course, and using approved manuals, the trainee shall be able to do the following:
OPERATION
A. Properly and safely operate the unit.
B. Hydraulic controls.
C. Engine controls.
D. Heater controls.
SYSTEM DESCRIPTION AND OPERATION
Describe the function and operation of:
A. The Auxiliary Engine and its driven components.
B. The Fluid System, Pump and their related components.
C. The Antiice System, Pump, and their related components.
D. The Heater Assembly and related systems.
E. The Hydraulic System.
MAINTENANCE SERVICE
Be able to find information for routine and mandatory maintenance and demonstrate the procedures for the following:
A. Fluid Pump service.
B. Heater Fuel Pump location and pressure adjustment.
C. Auxiliary Engine Governor service and adjustment.
D. Heater Blower service and adjustment.
E. Deice and Antiice Fluid System pressure adjustments.
F. Heater Burner Assembly inspection, cleaning and adjustment.
G. Heater temperature control adjustment.
H. Hydraulic System service and adjustments.
I. Electrical System tests, 220VAC, 120VAC and 12VDC.
J. Electrical System troubleshooting.
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
TABLE OF CONTENTS
Title
Chapter
Section Page
DESCRIPTION …………………………………………..1…………………...1
SPECIFICATIONS………………………………………..2………………..….1
C800 Chassis…………………………………………………………….........1
F800/F700 Chassis………………………………………………………........6
HYDRAULICS……………………………………………3……………….….1
Graphic Symbols ..…………………………………………………………...1
Component Location………………………………………………………..12
Hydraulic Schematics……………………………………………………….13
Adjustment Procedures………………………………………………….......23
FLUID SYSTEM…………………………………………4……………………1
Fluid Schematic Type I……………………………………………………….1
Fluid Schematic Type II………………………………………………………5
Fluid Adjustments…………………………………………………………….7
FMC HEATER……………………………………………5…………………...1
Specifications and Adjustments…………………………….…………………5
Heater Troubleshooting………………………………………………………11
ELECTRICAL SYSTEM…………………………………6……………………1
Graphic Symbols………………………………………………………………1
Electrical Schematics.…………………………………………………………7
Component Location..………………………………………………………..17
Heater Sequential Operation………………………………………………….18
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
Electrical Adjustments……..…………………………………………………32
BOOM ASSEMBLY……………………………………….7…………………..1
Boom Adjustments…………………………………………………………….2
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
DESCRIPTION
A. The FMC Model TM1800 TruckMounted Deicer is designed to deice aircraft of all sizes. Other uses include inspection/maintenance of aircraft and buildings.
B.
Mounted on a modified standard Ford F700 truck chassis, the TM1800 is versatile unit that incorporates fluid tanks, fluid heaters, and an aerial boommounted personnel basket. All components except the boom and aerial basket are enclosed in a shroud. The vehicle is stable without outriggers with a 450 – pound load in the basket and with the boom in any altitude.
C. The vehicle is capable of maneuvering around aircraft during deicing operations with the boom in any position and with two operators in the basket. The unit is suitable for highway travel with boom lowered and secured.
D.
The basic fluid system comprises two separate systems. One for deicing
(Type I) and the other for antiicing (Type II). The deicing system consists of a 1300 gallon tank 100GPM centrifugal pump and is heated by two gasoline fired heaters (1,00,000 BTU/HR/EA) to 185 o F. The fluid used is either Ethylene Glycol based, mixed with water at 50/50 or
Propylene Glycol mixed 60/40. This heated mixture then is applied to the appropriate aircraft surfaces to facilitate removal of ice and snow.
The antiicing system consists of a 500 gallon tank, 20 GPM diaphragm pump and is not heated. This fluid is either Ethylene or Propylene
Glycol based with a thickening agent added to increase adherence to the flight surfaces.
11
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
CHASSIS SPECIFICATIONS
CHASSIS
Make ………………………………………………………..Ford Motor Company
Model ………………………………………………………C800 with tilt cab
GVW ………………………………………………………35,000 LB
Dimensions
Wheel Base …………………………………………135 inches ( 3 430 mm )
Cab rear to rear axle centerline……………………...108 inches ( 2 743 mm )
Cruising speed ……………………………………………..50 mph ( 80.5 km/hr )
Alternator ………………………………………………….60 ampere, 12 volt
Battery …………………………………………………….63 ampere hour (535 C.C.A)12 volt
Engine …………………………………………………….Ford 370 H.D 4V, V8
Wind Shield Wipers ………………………………………2 speed electric
Brakes
Operating …………………………………………..Footoperated, full air, cam type
Parking, rear wheel ………………………………..Springset
Compressor ………………………………………………7 ¼ Cu. Ft. & low air buzzer
Transmission
Make and model ………………………………….Allison AT545 automatic
Speeds ……………………………………………4
Steering ………………………………………………….Power
Mirrors ………………………………………………….Dual western
Tires and wheels
Tire size ….……………………………………..11.00 x 20 (279 x 508 mm), G14 ply
Type …………………………………………….Mud/snow grip
Wheel size ………………………………………20 x 8.0 (508 x 203 mm) steel disc
Frame ………………………………………………….21.75 S.M36,000 psi
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
21
Spring load capacity
Front …………………………………………….5,400/6,000 pounds (2 449/2 722 kg)
Rear ……………………………………………..12,000/13,200 pounds (5 443/5 987 kg)
Fuel tank capacity ……………………………………..75 gallons (284 L)
Emission control ………………………………………Evaporative fuel system
Axle load capacity
Front ……………………………………………12,000 pounds (5 433 kg)
Rear
(Eaton Model 23121 ratio 6:67 )..28,000 pounds ( 10 433 kg )
DEICER
Dimensions
Height, overall, fluid tanks empty, boom stowed, and basket down ……………………………..11 feet, 8 inches (3 581 mm)
Length, overall, boom stowed ………………………..27 feet, 10 inches (8 230 mm)
Width, overall ………………………………………...8 feet (2 438 mm)
Gross vehicle weight …………………………………37,300 pounds (16 920 kg)
Curb weight …………………………………………..21,850 pounds (9 911 kg)
Wheelbase ……………………………………………135 inches (3 429 mm)
Turning radius ………………………………………..26 feet, 8 inches (8 128 mm)
Stabilization ………………………………………….Rear Spring lockout
Fluid System
Number of tanks …………………………………….1; with partitions 2 sections
( Type I premix and Type II fluid )
Tank material ………………………………………..Stainless steel
Fluid capacity ………………………………………..1,800 gallons (6 813 L)
Pumping system – Type I
Type …………………………………………..2 – stage centrifugal FMC JB2S
Capacity ……………………………………… 100 gpm (6.3 L/s) at 200 psi
Pumping system – Type II
Type …………………………………………..Diaphragm
Capacity ……………………………………….20 gpm
Heaters
Number ……………………………………….2
Type …………………………………………..Gasoline fired FMC
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
Output, each …………………………………..1,000,000 Btu/hr
22
Auxiliary Engine
Make ………………………………………………………….Ford Industrial
Size …………………………………………………………...300 CID (4.92 l) 6 Cyl.
Type …………………………………………………………..Gasoline
Boom
Working height, maximum …………………………………...48 feet (14.63 m)
Side reach, maximum ………………………………………...26 feet (7.92 m)
Rotation from forward center, maximum ……………………185 o left and right
Basket capacity, maximum …………………………………..2 men or 450 pounds (204 kg)
Yoke ………………………………………………………….Articulating
Ground Hose
Length ………………………………………………………..50 feet (15.24 m)
Hydraulic System
Type of system ………………………………………………Split open center
System relief …………………………………………………1800 psi
Recommended fluid ………………………………………….Mobil DTE
………………………………………………………………..DTE 13 (ambient temperatures
From 8 to 100 o F (22 to 38 o C)
Power Take Off (P.T.O.)
Make …………………………………………………………Twin Disk Incorporated
Model ………………………………………………………...SP111HP4
Type ………………………………………………………….Dry clutchover center
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
23
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
24
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
25
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
CHASSIS
Make …………………………………………………………Ford Motor Company
Model ………………………………………...........................F800/F700
GVW …………………………………………………………35,000 pounds
Dimensions
Wheelbase ……………………………………………..178 inches (4520 mm)
Cab rear to rear axle centerline ………………………..108 inches (2743 mm)
Cruising speed ……………………………………………….50 mph (80.5 km/hr)
Alternator …………………………………………………….60 amp, 900 watt, 12 volt
Battery ………………………………………………………..535 CCA 12 volt
Engine ………………………………………………………..Ford 7.0L (429), 4VV8
213 hp 3600 rpm
Ignition System ………………………………………………Solid state
Wind Shield Wipers ………………………………………….2 speed electric
Brakes
Service ………………………………………………..HD split power hydraulic disc
front, 15 x 7 x ¾ drum rear
Parking ……………………………………………….Rear spring set
Transmission
Make and model ……………………………………..Automatic Allison AT – 545
Speeds ………………………………………………..4
Mirrors ……………………………………………………...Dual western, AUX convex
Tires and Wheels
Tire size ………………………………………………11.00 x 20 (279 x 508 mm),
14 ply bias
Tire type front ………………………………………...Standard tread
Tire type rear ………………………………………….Mud/snow tread
Wheel size …………………………………………….20 x 8.0 (508 x 203 mm)
3 pc disc
Tire and wheel capacity front ………………………...13180.100 psi
Tire and wheel capacity rear ………………………….23120.90 psi
Frame ………………………………………………………..21.0 SM inverted L reinforced
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
26
Spring load capacity
Front ………………………………………………….12,000 pounds
Rear …………………………………………………..24,500 pounds plus 2500 pounds four leaf auxiliary
Fuel tank capacity …………………………………………..50 gallons right side
Emission control …………………………………………….Evaporative fuel type
Axle load capacity
Front …………………………………………………..12,000 pounds (5443 kg)
Rear …………………………………………………....23,000 pounds
Model make rear axle …………………………………S/S Rockwell RS23160
7.17 axle ratio
DEICER
Dimensions
Height, overall, fluid tanks empty, boom stowed, and
Basket down ………………………………………………….12 feet, (3654 mm)
Length, overall, boom stowed ………………………………..29 feet, 9 inches (9075 mm)
Width, overall ………………………………………………...8 feet (2 438 mm)
Gross vehicle weight …………………………………………37,300 pounds (16 920 kg)
Curb weight …………………………………………………..21,850 pounds (9 911 kg)
Wheelbase …………………………………………………….135 inches (3 429 mm)
Turning radius ………………………………………………...26 feet, 8 inches (8 128 mm)
Stabilization …………………………………………………..Rear spring lockout
Fluid system
Number of tanks ……………………………………………...1; with partitions 2 sections
(Type I premix and Type II fluid)
Tank material …………………………………………………Stainless steel
Fluid capacity …………………………………………………1,800 gallons (6 813 L)
Pumping system – Type I
Type ……………………………………………………2 – stage centrifugal FMC
JB2S
Capacity ………………………………………………..100 gpm (6.3 L/s)
Pumping system – Type II
Type ……………………………………………………Diaphragm
Capacity ………………………………………………..20 gpm
Heaters ………………………………………………………...2
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
Type ……………………………………………………Gasoline fired FMC
Output, each ……………………………………………1,000,000 BTU/hr
Fuel system
Tank ……………………………………………………2 (50 U.S. Gallons)
100 gallons total
27
Auxiliary Engine
Make ……………………………………………………..Ford Industrial
Size ………………………………………………………300 CID (4.92 L) 6 Cyl.
Type ……………………………………………………...Gasoline
Boom
Working height, maximum ………………………………48 feet (14.63 m)
Side reach, maximum ……………………………………26 feet (7.92 m)
Rotation from forward center maximum …………………………………………….185
o left and right
Basket capacity, maximum ………………………………2 men or 450 pounds (204 kg)
Yoke ……………………………………………………..Articulating
Wind speed stability
Boom withstanding maximum ……………………….60 mph (96.56
Wind pressure, 60 MPH maximum ………………….10.9 psf
Ground Hose
Length ……………………………………………………50 feet (15.24 m)
Hydraulic System
Type of system …………………………………………...Split open center
System relief ……………………………………………..1800 PSI
Recommended fluid ……………………………………...Dry clutchover center
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
28
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
29
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
210
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
211
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
31
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
32
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
33
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
34
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
35
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
36
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
37
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
38
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
39
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
310
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
311
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
312
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
313
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
314
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
315
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
316
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
317
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
318
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
319
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
320
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
321
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
322
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
HYDRAULIC SYSTEM ADJUSTMENTS
MAIN HYDRAULIC RELIEF VALVE ADJUSTMENT ( SYSTEM “A” )
NOTE: The main pressure relief valve is located in the auxiliary engine compartment under the engine rear mount Gage Point A ).
A.
Start the engine and allow it to reach operating temperature. Stop the engine.
B.
Remove the ¼ inch (6.35 mm) plug from the front of the relief valve (Gage Point A).
Insert a 0to2,500 psi (0to175kg/cm 2 ) pressure gage.
C.
Start the engine. Set the speed at 2000 rpm with no load.
D.
Raise the boom fully and adjust valve pressure to 1,800 psi with the boom in the stalled condition.
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
323
NOTE: The relief – valve pressure should not exceed 1,800 psi when the boom reaches the end of travel.
E.
Stop the engine, remove the gage, and replace the plug.
PILOTPRESSURE HYDRAULIC RELIEF VALVE ADJUSTMENT
NOTE: The pilotpressure relief valve is located on the right side of the rotator base on top of the vehicle.
A.
Start the auxiliary engine and allow it to reach operating temperature.
B.
Stop the engine.
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
324
C.
D.
Remove the ¼inch (6.35 mm) plug from the side of the main hydraulic relief valve and insert a 500502,000psi (70to175kg/cm 2 ) pressure gage into Gage Point A (located in the auxiliary engine compartment under the rear engine mount).
Start the engine. Set engine speed at 2000rpm with no load.
E.
Remove the cap from the relief valve in the rotator. Adjust valve pressure to 800 psi or
1200 psi with the boom down switch actuated.
F.
Replace the cap on the relief valve.
G.
Stop the engine. Remove the pressure gage and replace the cap in the main relief valve.
BOOMLOWER SPEED ADJUSTMENT
CAUTION: DO NOT ALLOW PERSONNEL UNDER THE BOOM OR BASKET UNLESS
THE BOOM IS STOWED IN THE RESTING SADDLE AND THE BASKET IS
AT GROUND LEVEL.
A. Extend and raise the boom fully.
B.
With the boom fully extended, lower it fully. The boom should travel the full distance in
30 +
5 seconds.
C. To decrease the speed, screw in the flowcontrol valve at the base of the lift cylinder. To increase the speed, screw the valve out.
BOOMROTATION SPEED ADJUSTMENT
FAST SPEED
A. The flowcontrol valve is mounted inside the rotator near the right rear corner. Unscrew the valve for less speed.
B.
Raise the boom a few feet from the rest saddle and rotate 90 degrees in either direction.
Rotation time should be 30 +
5 seconds.
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
325
SLOW SPEED
A. The camoperated slowspeed control valve is located inside the top of the rotator well.
Screw the valve in for less speed.
B. Raise the boom several feet from the resting saddle and rotate it about 175 degrees from center. The camoperated valve should be actuated.
C. Set the flow control for about onehalf normal speed when actuated (to gently nudge the boom against the stop).
BOOM YOKE SPEED ADJUSTMENT
Note: The yoke speed flow control valve is located on the boom manifold assembly.
A. Lower the yoke assembly to the full down position.
B. Raise the yoke to the full up position. The yoke should travel the full distance in 30 + 5 seconds.
C. Adjust flow control valve clockwise to increase speed, adjust counterclockwise to decrease speed.
TYPE II ANTIICING HYDRAULIC PRESSURE ADJUSTMENTS
A. System “B” Main Relief Valve
1.
Disconnect hose at the “P” port (pressure inlet) on the priority valve and cap the hose and the fitting on the priority valve.
2. Install 3000 PSI gauge in the gauge port of the main relief valve.
3. Start engine and operate 2000 RPM.
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
4. Adjust relief valve to 2000 PSI and lock adjusting screw securely.
5. Stop engine and reconnect hose to the priority valve.
6. Remove pressure gauge and replace plug in gauge port.
326
B. Priority Valve/Relief Valve
1. Remove hose from fitting on priority valve marked “CF” and cap hose and fitting. (This is the hose to the ADF pump drive motor).
2. Remove plug and install 3000 PSI pressure gauge in “G” port on priority valve.
3. Start engine and operate at 2000 rpm.
4. Adjust priority relief valve to 1500 psi and then lock adjustment securely.
5. Remove caps and reconnect hose to port marked “CF”.
6. Remove pressure gauge and reinstall plug in “G” port.
ANTIICING FLUID PUMP, SPEED ADJUSTMENT
1. Start engine and set speed to 2000 RPM.
2. Check speed of diaphragm pump (antiicing) drive motor by using a photo tachometer on the drive coupling.
a. Start pump by squeezing trigger on the antiicing nozzle.
3. Adjust speed of pump/motor by turning the adjusting screw on the priority valve to obtain
250255 RPM.
a. Turn adjustment screw clockwise to increase RPM and counterclockwise to decrease
RPM. Tighten locknut securely after making any adjustments.
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
327
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
328
ADJUSTMENT OF BLOWERRELIEF VALVE
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
CAUTION: BEFORE STARTING AUXILIARY ENGINE, CHECK THE LEVEL OF
THE FLUID TANKS, TYPE I TANK 400 GALLONS MINIMUM
A. Check the fuel supply, as indicated by the fuel gauge.
B. Disconnect hydraulic tube from Tee below Heater #2 Blower assembly, cap and plug the open ends.
C. Locate the blower pressure relief valve in the auxiliary engine left rear close to the engine. Connect a pressure gauge 03000 psi to the gauge port of the relief valve.
D. Start the engine and allow it to warm up. Engage the fluid pump clutch and raise the engine speed to 2000 rpm.
E.
Energize the blower enable coil SOL 14 by connecting a jumper wire between terminals #42 and #59C on the terminal strip in the main panel.
F. Loosen the jam nut on the relief valve. Turn the adjusting screw clockwise to increase hydraulic fluid pressure or counterclockwise to decrease pressure; set the pressure at 1800 psi; tighten the jam nut.
G. Remove the jumper wire, reduce the engine speed, disengage the fluid pump clutch.
Allow the engine to idle for a few minutes, then shut off.
H. Remove the plugs from the line and flow control valve and reconnect the line to the inlet port. Remove the pressure gauge.
329
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
ADJUSTMENT OF BLOWER SPEED
NOTE: To ensure correct adjustment when setting the blower speed, the use of a photo tachometer or strobe scope is required.
CAUTION: BEFORE STARTING, MAKE CERTAIN THERE IS SUFFICIENT
FLUID IN THE WATER AND ANTIDEICING FLUID TANKS.
FLUID
OPERATION OF THE UNIT WITH INADEQUATE SUPPLY OF
COULD DAMAGE THE FLUID PUMPS.
A. Check the fuel supply.
B. Remove the cover of top shroud to allow a view of the blower inlets and impellers. Make a mark with white paint or reflective tape to allow use of the photo tachometer or scope.
C. Locate the heater blower speed control valve in the rear of the auxiliary engine compartment.
D. Start the engine and allow it to warm up. When operating temperature is reached, adjust the engine speed to 1000 rpm and engage the fluid pump clutch. Increase the engine speed to 2000 rpm.
E.
Turn both heaters to the ON position only. DO NOT TURN HEATER
SWITCHES TO “START” POSITION.
F. Measure blower speed with photo tachometer or strobe scope located at the top of each heater.
G. Adjustment of the flow control valve described in step C, above changes the blower speed of both heaters. After loosening the jam nut, turn the adjusting screw in (clockwise) to reduce blower speed, and out (counterclockwise) to increase the speed. Operating speed should be set at 3,350 to 3,450 rpm.
NOTE: the blower speed control valve effects the speed of both motors
H. Tighten speed adjustment jam nut to lock the screw.
I.
Turn off both heaters.
J.
Slow engine to idle speed and disengage the clutch. Allow engine to idle for two minutes, then shut off.
K. Replace top shroud and fasten.
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
L. Check for possible fluid leaks.
330
BOOM BASKET BLEEDING INSTRUCTIONS
A. Remove the plug and fill the reservoir with MIL5606 fluid to within 1 inch of the top.
Maintain this level throughout the bleeding procedure.
B. Open both flowcontrol valves and the needle valve fully. Allow the unit to sit undisturbed for about 4 hours.
C. Raise and lower the boom and yoke several times, so that the basket rotates to the maximum limits, until no air bubbles are evident in the reservoir fluid. End the cycle with the basket at the highest point.
D. Close the needle valve. Repeat step C, but end the cycle with the basket at the lowest point of rotation.
E. Close the inboard floecontrol valve. Recycle the yoke until no bubbles are evident in the reservoir fluid. (CAUTION: THE BASKET IS LOCKED AT THIS POSITION.)
Open the inboard flowcontrol and momentarily actuate the yoke control.
F. Loosen the bleed plug at the top of the cylinder piston rod until no air escapes from the port. Reinstall the plug snugly.
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
331
G. Raise the boom fully. Remove the cylinder bleed plug. Cycle the yoke to the fully up position, then reinstall and secure the plug. Check for firmness of stabilization. If sponginess is evident, repeat the entire bleeding procedure.
H. Lower the boom. Adjust the flowcontrol valves two turns from closed and secure them with setscrews.
I. Refill the reservoir to within 1 inch of the top and reinstall the plug.
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
332
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
41
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
42
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
43
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
44
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
45
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
46
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
47
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
48
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
51
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
52
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
53
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
54
FMC HEATER
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
SPECIFICATIONS AND ADJUSTMENTS
ALL MODEL TM1800 AND LA1000 DEICERS
CAPACITY EACH HEATER…………………………………………1,000,000 BTU
BLOWER SPEED – GAS (NOTE 1)…………………………………..3,350 – 3,450 RPM
BLOWER SPEED – DIESEL (NOTE 1)………………………………3,750 – 3,850 RPM
FUEL PRESSURE (GAS)……………………………………………...36 – 40 PSI
ALL EXCEPT TM1800 UNITS DB046 AND UP. (NOTE 2)
FUEL PRESSURE (GAS)……………………………………………...95 – 100 PSI
TM1800 UNITS DB046 AND UP (NOTE 2)
LOW FLAME NOZZLE (QTY. 2) – GAS……………………………..8.3 x 90 o
ALL EXCEPT TM1800 UNITS DB046 AND UP .
LOW FLAME NOZZLE (QTY. 1) – GAS……………………………..F8.50 x 80 o
TM1800 UNITS DB046 AND UP ONLY
HIGH FLAME NOZZLE (QTY. 1) – GAS…………………………….4.00 x 90 o
ALL EXCEPT TM1800 UNITS DB046 AND UP .
HIGH FLAME NOZZLE (QTY. 1) – GAS…………………………….F2.50 x 80 o
TM1800 UNITS DB046 AND UP ONLY
LOW FLAME NOZZLE (QTY. 2) – DIESEL…………………………4.00 x 90 o
HIGH FLAME NOZZLE (QTY. 1) – DIESEL…………………………2.25 x 80 o
FUEL PRESSURE (DIESEL)…………………………………………..95 – 105 PSI
ELETRODE (SPARK) GAP – ALL…………………………………….3/32 INCH
ELECTRODE DISTANCE AHEAD OF SPINNER PLATE………….5/16 INCH
ALL (NOTE 3)
AIR PRESSURE SWITCHES (2PS & 3PS) – ALL…………………….1,800 – 2,000 RPM
ACTUATES AT BLOWER SPEED OF (SEE NOTE 4)
TANK TEMPERATURE SWITCH – HIGH FLAME ……………….150
o
CUT OUT. ALL
F
TANK TEMPERATURE SWITCH – LOW FLAME ………………….180
o
CUT OUT. ALL
F
HEATER OVERTEMPERATURE SWITCH – ALL ………………….255
o F
POST PURGE (BLOWER RUN) TIMERS – 12 VOLT ………………180 SECONDS
PREPURGE (GREEN READY0 TIMERS – 12 VOLT ………………10 SECONDS
IGNITION TRIAL – TIMERS – 120 VOLT AC ………………………10 SECONDS
BLOWER MOTOR RELIEF SETTING (HYD) ALL …………............1,800 PSI
FLOW SWITCH – TYPE I – ACTUATES AT (SEE NOTE 5) ……….1,600 – 1,800 RPM
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
55
FLOW SWITCH – ADF – ACTUATES AT ……………………..1,600 – 1,800 RPM
(SEE NOTE 5)
FLUID RELIEF VALVE SETTING – ADF ……………………..170 – 190 PSI
(SEE NOTES 5 & 6)
FLUID RELIEF VALVE HEATER BYPASS ………………….60 PSI
(SEE NOTE 7)
NOTES:
WARNING: DO NOT BYPASS OR JUMPER ANY SWITCH RELATED TO HEATER
AND
OPERATION. DOING SO MAY CAUSE DAMAGE TO EQUIPMENT
DEATH OR INJURY TO PERSONNEL.
1.
Measure blower impeller speed with PHOTOTAC or STROBESCOPE.
Heater switches to the “ON” position only. (DO NOT START). Engine speed should be set at operate RPM when making blower speed adjustments.
TM1800 – 2,000 RPM.
2.
Adjust with heaters operating to obtain Clean Burn. Check intake and exhaust screens for soot or obstruction.
3.
Measured at closest point between electrodes.
4.
5.
6.
Measure blower speed with PHOTOTAC or STROBESCOPE. Heater switches to “ON” position only. (DO NOT START). Gradually raise engine speed from idle. Pressure switch should actuate when blower speed reaches
1,800 – 2,000 RPM.
Engage PTO clutch at 1,000 RPM engine speed. Type I no-flow light should illuminate. Gradually raise engine speed. The Type I light should go out between 1,600 – 1,800 RPM. (See Note 6).
Type I relief valve is adjusted so that the Type I light goes out at 1,600 –
1,800 RPM engine speed and has a working pressure 170 to 190 PSI at operating RPM engine speed.
7.
Factory set at 60 PSI. Do not adjust.
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
56
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
57
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
58
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
59
FUEL VALVE TEST
NOTE: Do not run the auxiliary engine for this test.
A.
Remove the nozzles from the burner assembly of heater 1, the forward heater in the auxiliary engine compartment.
B.
To momentarily engage the fuel pump, connect a jumper wire between the engine circuit breaker wire #10 and terminal #53 on the main terminal block in the main panel.
C.
Ensure that no fuel flows from the burner assembly nozzle tubes.
D.
Remove the jumper wire.
E.
For heater 2 valve test, repeat step 1, 3, & 4. to momentarily engage the fuel pump for heater 2, connect a jumper wire between wire #10 on the engine circuit breaker and terminal #69 on the main terminal block in the main panel.
F.
Inspect the filter screen of each nozzle and remove dirt, flakes of rust, and other particles, then replace nozzles and burner assembly.
Igniter Replacement and Adjustment
A.
Loosen the bushing nut and remove the broken igniter. Insert a new igniter.
B.
Set the distance from the center of the spark gap to the back of the spinner at
5/16 inch. Set the spark gap at 3/32 inch, then tighten the bushing.
NOTE: The igniter must be properly positioned within the jet stream of fuel.
NOTE: Tighten bolts snugly but not so tightly that the ceramic insulators are crushed. The proper torque is 173 inchpounds
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
510
PRIMARY TROUBLESHOOTING.
Before troubleshooting a heater a Heater malfunction start with the following steps:
A. Check the Fuel Level ( Min ½ Tank )
B.
Check the fluid temperature gage ( Below 130 o F )
C. Check the Fluid levels TYPE I ( Min. 200 Gal. )
D. Check the TYPE I Pressure Gage ( 170 – 190 PSI )
E. Check Indicating Lights.
1.
NO FLOW indicates possible, No Fluid, or Pump Requires PURGING.
2. NO AIR indicates possible Low Blower Speed or faulty Pressure Switch.
3. MISFIRE indicates possible No Fuel, No Spark, Inverter, flame Detector or
Flame Sensor.
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
511
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
61
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
62
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
63
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
64
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
65
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
66
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
67
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
68
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
69
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
610
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
611
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
612
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
613
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
614
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
615
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
616
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
617
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
618
FMC HEATER
A STEPBYSTEP SEQUENTIAL OPERATION OF THE TM1800 FMC HEATER
ELECTRICAL CIRCUIT.
NOTE
A. The information provided is designed to help Airline Ground Support equipment personnel in obtaining a clear understanding of the “Electrical Operation” for the FMC
Fluid Heater(s) mounted on the TM1800 Deicer/Washer. The information is also designed to help in the troubleshooting and diagnosis of a heater malfunction and should be used in conjunction with pertinent FMC Heater Electrical schematics applicable to the TM1800 Deicer/Washer with dual heater installation.
B.
The information is based on the understanding that the fluid system has sufficient fluid, the hydraulic system (which drives the fan motor ) is functioning properly, the engine is running at the correctly rated R.P.M. and that all warning lights, controls and switches are working properly.
C.
The code number on the left side of the information sheets shows the wire routing for each individual circuit provided for on Pages through . The line number as shown on the FMC ladder prints.
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
619
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
MAIN CONTROL PANEL ASSEMBLY
620
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
Heater # 1START UP SEQUENCE (ELECTRICAL)
STEP # 1 ENGINE AT 1000 R.P.M. AND P.T.O. CLUTCH ENGAGED
CODE LINE
1 6LS
2 TYPE I no
3 flow LT
Contacts will close when P.T.O. clutch is engaged.
Will be “ON” as 6LS contacts close and
1FS not yet actuated.
63
64
65
NOTE: 1FS Will actuate when engine speed reaches 1600 to 1800 R.P.M. The
“no floe” lights will remain on if 1FS is at fault or flow is insufficient.
4 1FS
TYPE I no
Flow LT
5 8CR
STEP #
Will actuate energizing 8CR
Will go out – 1FS – actuated
Will go out – 1FS – actuated
Contacts will close
63
64
65
54
STEP # 3 HEATER SWITCH – 6SS TO THE “ON” POSITION
6 5CR
7 6CR
8 1TD
9 13SOL
10 14 SOL
11 23LT
Is energized
Is energized
Is energized
Is energized – through contacts of 1TD
Is energized – through contacts of 1TD
“NO AIR” is illuminated
51
52
53
66
66A
62
NOTE: The “no air” light 23LT will go out when correct blower pressure is obtained. The circuit for 23LT is through one set of contacts of blower pressure switch – 2PS. 2PS is actuated when the blower speed reaches
1800 to 2000 R.P.M. If 2PS is not actuated, the prePURGE timer 2TD will not be energized; no green ready light will be available. Line 55.
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
621
CODE
STEP #
12 2PS
13 2TD
14 19LT
Is actuated, the “no air” light go out
Is energized thru 1 set of contacts 2PS
Will illuminate after ten seconds
LINE
55
54
55
NOTE: After ten seconds, the normally open contacts of the prePURGE timer
2TD will close and the green ready light 19LT will be on. At this point, the heater is ready to start; there should be no red warning lights on at this time.
STEP # 5 – HEATER SWITCH 6SS TO THE “START” POSITION
15 7CR
16 3CON
17 22LT
Is energized
Is energized – (inverter contactor)
Misfire light may flash
56
61
60
NOTE: The misfire light 22LT may flash on then off very quickly. This is normal and indicates that the inverter is working and that 120 volts AC is available. If 22LT remains on at this point, it would indicate a fault in the inverter or in the 120 VAC circuit. Also, the low and high flame lights
20LT & 21LT will not illuminate.
STEP # 63 CON CONTACTS CLOSEDINVERTER ENERGIZED
120 VOLTS AC AVAILABLE
CAUTION: ALL WIRES MARKED #75 AND UP CARRY 120 VOLTS AC 78
Thru
The following will be energized with 120 106
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
Volts AC through 7CR contacts from the inverter:
622
CODE
18 1T
19 1FD
20 1FLS
21 5TD
Ignition transformer
Flame detector
Flame sensor
Ignition timer – ten seconds
22 10CR Ignition interlock
23 16SOL Low flame fuel solenoid
24 17SOL High flame fuel solenoid
25 11CR Low flame interlock
26 2MTR
27 20LT
28 21LT
29 22LT
STEP # 7 – IGNITION SPARK AVAILABLE, FUEL
SOLENOIDS 16SOL & 17SOL “OPEN”
Fuel pump energized through now closed
Contacts of 11CR
Low flame light – illuminated
High flame light – illuminated
Misfire light will be out
1FLS
1FD
5TD
STEP #8 – FLAME AVAILABLE
Flame sensor will see the flame and
Signal the flame detector
Will sense the signal from the flame
Sensor, a set of contacts in the detector, line
91, will close before 5TD contacts open
Will time out after ten seconds. Its contacts ` will open cutting the circuit to the ignition transformer & 10CR. The contacts of the flame detector will hold in to the flame detector
Will hold in to energize 11CR, 16SOL & 17 SOL
30 3TAS
STEP #9150 DEGREE TEMPERATURE REACHED
Will open
LINE
85
82
84
85
89
91
90
57
58
59
60
83
82
84
52
Ground Support Equipment
6CR
31 12CR
TM1800 DEICER MAINTENANCE TRAINING
Is deenergized – through open contacts of 3TAS
Is energized – through N.C. contacts of 6CR
17SOL Is deenergized – through now open
Contacts of 12CR
92
52
91
623
CODE
21LT Will go out as N.C. contacts of
12CR will be open
CODE
60
STEP #10180 DEGREE TEMPERATURE REACHED
2TAS Will open
5CR Is deenergized through now open contacts of 2TAS.
with 5CR contacts open, power is cut off to the
INVERTER. CONTACTORCON 3 cutting off the fuel solenoids. The low flame light will go out.
51
51
STEP #11HEATER SWITCH 6SS TO “OFF POSITION”
Power is cut to all control relays except 8CR
1TD Post purge timer will run for three minutes, its contacts will then open dropping out 13SOL & 14SOL blower run solenoids.
53
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
624
HEATER #2START UP SEQUENCE
STEP #1ENGINE AT 1000 R.P.M. AND P.T.O. CLUTCH ENGAGED
CODE
1 6LS Contacts will close when clutch
P.T.O. is engaged
2 TYPE I no Will be on as 6LS contacts close
3 flow LTs and 1FS not yet actuated
NOTE: The flow switch 1FS will actuate when engine speed reaches 1600 to 1800 R.P.M. The “no flow” lights will remain on if 1FS is at fault or, the flow has stopped or is insufficient.
LINE
63
64
65
STEP #2ENGINE SPEED AT 2000 R.P.M.
4 1FS Will actuate energizing 8CR
5 TYPE I no Will go out 1FS actuated
6
7 flow LTs
8CR
Will go out 1FS actuated
Will close
8 5CR
STEP #3HEATER 7SS TO “ON” POSITION
Is energized
63
64
65
54
51
9
10 3TD
6CR
11 14SOL
12 15SOL
13 30LT
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
Is energized
Is energized
Is energized through contacts of
3TD
Is energized through contacts of
3TD
“No Air” is illuminated
68
66A
66C
76
52
625
17
18
19
CODE LINE
NOTE: The “no air” light 30LT will go out when correct blower pressure is obtained. The circuit for 30LT is through one set of contacts of the blower speed reaches
1800 to 2000 R.P.M. and up. If 3PS is not actuated, the
PrePURGE timer 4TD will not be energized. No green ready light will be available.
14
15
3PS
4TD
16 26LT
STEP #4BLOWER PRESSURE AND FLUID FLOW AVAILABLE
Is actuated, the “no air” light will go out
Is energized through one set of contacts of 3PS illuminated after ten seconds
69
69
70
NOTE: After ten seconds, the normally open contacts of the
PrePURGE timer 4TD will close and the green ready light 26LT will be on. At this point, the heater will be ready to start. There should be no red warning lights on at this time.
STEP #5HEATER SWITCH & 7SS TO “START POSITION”
9CR
3CON
29LT
Is energized
Is energized ( inverter contactor )
“Misfire” light may flash
71
61
75
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
NOTE: The “misfire” light 29LT may flash on then off very quickly, this indicates that the INVERTER is working and that 120 volts AC is available If 29LT remains on, it would indicate a fault in the INVERTER or in the 120 volt
AC circuit. Also the high and low flame lights will not
Illuminate.
626
CODE
STEP #63CON CONTACTS CLOSEDINVERTER ENERGIZED
120 VOLTS AC AVAILABLE
LINE
CAUTION:ALL WIRE MARKED #75 & UP CARRY
120 VOLTS AC
The following will be energized with 120 volts AC through
9CR contacts from the INVERTER:
78
thru
106
20
21
2FD
2FLS
22 6TD
23 13CR
24 2T
25 18SOL
26 19SOL
27 14CR
Flame detector
Flame sensor
Ignition interlock
Ignition interlock
Ignition transformer
Low flame fuel solenoid
High flame fuel solenoid
Low flame interlock
99
102
104
103
95
96
97
98
STEP #7IGNITION SPARK AVAILABLE FUEL
SOLENOIDS 18SOL & 19SOL OPEN
28
29 low flame LT Low flame light illuminated
30
31
3MTR
28LT
29LT fuel pump energized through now closed contacts of 14CR
High flame light illuminated
“Misfire” light will be out
72
73
74
75
CODE
2FLS
2FD
6TD
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
STEP #8FLAME AVAILABLE
Flame sensor will signal the detector
Flame detector will sense the signal from the flame sensor, a set of contacts in the detector will close before 6TD contacts open
Will time out after ten seconds; its contacts will open, cutting the circuit to the ignition transformer and fuel solenoids.
The contacts of the flame detector will hold in to energize 18 & 19SOL fuel solenoids
96
95
97
627
STEP #9150 DEGREE TEMPERATURE REACHED
3TAS
6CR
15CR
28LT
Will open
Is deenergized through contacts of
3TAS
Is energized through N.C. contacts of
6CR
19SOL Is deenergized through now open
Contacts of 15CR
Will go out as N.C. contacts of 15CR will be open
LINE
52
52
105
104
74
STEP #10180 DEGREE TEMPERATURE REACHED
2TAS
5CR
Will open
Is deenergized through now open contacts of 2TAS. With 5CR contacts open, power is cut off to the INVERTER
CON 3 cutting off the fuel solenoids.
The low flame light will go out.
51
51
STEP #11HEATER 7SS TO “OFF” POSITION
3TD
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
Power is cut to all relays except 8CR
Post PURGE timer will run for three
Minutes; its contacts will then open
Dropping out 14 & 15 SOL blower run
Solenoids
68
628
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
629
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
630
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
631
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
632
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
633
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
634
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
71
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
72
Ground Support Equipment
TM1800 DEICER MAINTENANCE TRAINING
73