advertisement
Product information
Door telephone
ISH3030
TCS TürControlSysteme AG, TCS Hotline Germany: +49 (0) 41 94/ 9 88 11 88
Mail: [email protected]
Subject to technical changes.
ISH3030-0140 UK 2 A
2 07/2013
Table of contents
Substitution of an indoor station
– programming bell buttons ......................................... 14
TCS TürControlSysteme AG
Mail: [email protected]
Subject to technical changes.
ISH3030-0140 UK 2A
07/2013 3
Scope of delivery
1 x indoor station ISH3030: upper cover, lower cover, handset with connecting line product information instruction manual
Safety instructions
Notice! Mounting, installation, commissioning and repair of electrical devices have to
!
be carried out only by qualified electricians! Thus the standards and rules for the installation of systems must be observed!
When installing TCS:BUS systems the general safety regulations for telecommunication systems after VDE 0800 have to be observed:
separated conduit of heavy current and low current lines,
minimum distance of 10 cm in case of a common conduit,
use of separators between heavy and low current lines in shared cable ducts,
use of standard communication lines, e.g. J-Y (St) Y with a diameter of 0.8 mm,
existing lines (modernisation) with deviating diameters can be used in compliance of the loop resistance.
!
With suitable requirements to protect against lightning it is imperative that the electric tension of each 32 V DC is not exceeded at the connections a,b,P,E.
Intended use
The ISH3030 are door telephones for the object area.
They are suitable for the operation in TCS audio systems and combined audio / video systems.
They are suitable for surface-mount.
max. number ISH3030 in 2-wire operation
In case of using power supply and control unit
BVS20 or
NBV1000, 1 line
BVS100, distributed on 3 lines
max. number
ISH3030
20
80
PSG02, 1 line 30
TCS TürControlSysteme AG
Mail: [email protected]
Subject to technical changes.
ISH3030-0140 UK 2A
4 07/2013
max. number ISH3030 in 3-wire operation
in case of using power supply and control unit
BVS20 or
NBV1000, 1 line
max. number
ISH3030
20
BVS100, distributed on 3 lines
80
PSG02, 1 Strang
BVS20 + NGV1011,
1 line
BVS100 + NGV1011,
3 lines
90
90
270
AS front-door station
VS power supply and control unit
IS indoor station
Note: The number of the max. connectable AS is limited and is described in their product information!
Indication and operating elements
handset call OFF button
communicating to the door
end communication
press short: ring tone stopper
press for 8 s: initiate ring tone selection
○
indication call OFF
(red) control key
ON: call OFF activated
error indication total error: both LEDs flashing
ring tone selection: both LEDs are ON call display (green) light switch button
control function 8
ring tone selection internal call
ON: call, communication activated
Blinking 3 x: busy speech channal
error indication: both LEDs flashing
ring tone selection: both LEDs are ON
switching lights
ring tone selection floor call (from the flat door) door release button
open the door
trigger light switch function*
ring tone selection door call from front-door station
volume control for
voice output
ring tone adjustable in 8 steps:
in case of an existing communication
in case of off-hook handset (no communication)
* if the light switch function in the front-door station is activated
TCS TürControlSysteme AG
Mail: [email protected]
Subject to technical changes.
ISH3030-0140 UK 2A
07/2013 handset
5
Device overview
call display (green) indication call OFF (red) call OFF button light switch button control key ring tone loudspeaker door release button volume control handset connecting line
Technical data
Supply voltage:
Housing:
Dimension (in mm):
+24 V ± 8 % (power supply and control unit) plastic (colors like shown in the price list)
H 180 x W 100 x D 50
Weight 340 g
Acceptable ambient temperature: -5 ...+ 40 °C
Degree of protection: IP30
Input current, standby
Max. input current:
2-wire operation: I(a) = 1 mA
3-wire operation: I(a) = 0.2 mA, I(P) =0.8 mA
I(Pmax) = 70 mA
TCS TürControlSysteme AG
Mail: [email protected]
Subject to technical changes.
ISH3030-0140 UK 2A
6 07/2013
Short description
large, deteched, blue door release button
light switch button
control button with control function 8
call OFF button for ring tone mute with optical display
optical indication of door calls via LED (green)
optical indication of a busy line when voice communication is established via LED
(green)
ring tone can be adjusted by the resident, selection out of 13 in improved quality
voice volume and ring tone volume manually adjustable
acoustic call distinction between 2 front-door stations (via configurations software configo™), flat door (floor door) and internal call
one parallel call can be activated (via Service Device TCSK-
01 or configo™)
audio privacy function and automatic call cut-off (after 2 min)
magnetic handset cradle
pluggable handset cord
lower cover with plugged screw terminal can be pre-installed and used alternative for sister product for hands-free talking
optical and acoustic error indication
can be functional extended by mounting places for call relays, controlling the radio signal device and EnOcean radio interface
energy efficient by a lower stand-by consumption of only 0.025 W
Installation
Install the lower cover
For placing the connection cables without any problems, a flush-mounted socket must be installed behind the device.
Position the flush-mounted socket below the cable conduit.
Install the lower cover with three screws.
TIPP: Avoid tearing of the straps:
For fixing the straps do not use counter-head screws or flat washers!
TCS TürControlSysteme AG
Mail: [email protected]
Subject to technical changes.
ISH3030-0140 UK 2A
07/2013 7
Connecting the lines (2-wire technique)
Minimize the length of the lines above the lower cover to place the lines without any problems and without clamping the lines when snapping-on the upper cover.
Connect the lines according to the labeling at: a b E P (from the bottom to the top), floor push-button at a
– E.
Snapping-on the upper cover
Set on the upper cover at both adjustment increments of the lower cover (1).
Snap-in the upper cover below with slight pressure (2)
1
2
Connect the handset
Put the western plug of the handset cord into the socket at the underside of the telephone.
TCS TürControlSysteme AG
Mail: [email protected]
Subject to technical changes.
ISH3030-0140 UK 2A
8
Open the device
Remove the handset cord.
There is a rectangular release opening at the underside of the device. Insert a small screwdriver straight and with slight pressure into this opening.
The upper cover can be removed at the underside (1).
Lift the upper cover out of the two upper adjustment increments (2).
07/2013
2
Installation of extended functions
TRE1 radio transmitter board
FFS3100
1
radio interface FBI4200
The extended functions (and the antenna) have to be fixed with adhesive pads in the indoor station (see also product information of the corresponding extended function).
TCS TürControlSysteme AG
Mail: [email protected]
Subject to technical changes.
ISH3030-0140 UK 2A
07/2013 9
Connecting the lines
Connecting lines
permitted cross-section (diameter)
0.08 … 0.82 mm
2
(Ø
0.32 … 1.0 mm)
max. number of wires per terminal contact each 2 x 0.8 mm, 3 x 0.6 mm
!
Further wires have to be connected via auxiliar terminals!
! Use only connecting lines with the same diameter in one terminal contact.
Wiring diagram
TCS TürControlSysteme AG
Mail: [email protected]
Subject to technical changes.
ISH3030-0140 UK 2A
10 07/2013
Connection diagram 2-wire technique Connection diagram 3-wire technique
Replacing an ISH1030 or TTS1 by an ISH3030
The floor push-button have to be connected always to the a-wire.
In case of a parallel circuit both telephones have to be replaced by the ISH3030.
Commissioning
Install the devices of the system voltage-free and completely.
Proof the a-, b- and P-wire against each other on short-circuit.
Switch on the main voltage.
Note:
If the floor push-button is not working, proof, i fit is connected to the a-wire of the power supply and control unit.
Settings
Pre-adjusted times
communication time flashing period of the green LED, if the voice channal is busy after lifting the handset internal standby time, if the device is calling or is called max. 2 min
2 sec around
30 sec
3 x flashing
TCS TürControlSysteme AG
Mail: [email protected]
Subject to technical changes.
ISH3030-0140 UK 2A
07/2013 11
2-wire/3-wire operation
The jumper J1 is adjusted for 2-wire operation in delivery condition. J1
2-wire operation (scope of delivery)
Put the jumper J1 on the two upper contacts for the 3-wire operation.
3-wire operation
Ring tone selection
For 4 different incoming calls (door calls of 2 different front-door stations, floor call, internal call) different ring tones can be selected.
1
End communication. Press call OFF button for ca. 8 s.
Both LEDs are on and an acknowledgement tone sounds, the ring tone selection is activated.
By pressing the following buttons a ring tone can be selected. You can chose between 13 tones.
2a
select door ring tone from the front-door station*
2b select door ring tone of floor door
Press the door release button as often as the required ring tone sounds. The ring tone selected last, will be stored.
Press the light switch button as often as the required ring tone sounds. The ring tone selected last, will be stored.
2c
select internal ring tone
3
Press the control key as often as the required ring tone sounds. The ring tone selected last, will be stored.
Press call OFF button short.
In case that no button is pressed for ca. 8 s, the device ends the ring tone selection automatically. Both LEDs go out and an acknowledgement tone sounds, the ring tone selection is deactivated.
* The ring tone is identical for all front-door stations and can be selected only identically for all.
For selecting a second door ring tone it is necessary to activate the call distinction by changing the audio AS limit.
Changing the audio AS limit is only possible with the configuration software configo™.
TCS TürControlSysteme AG
Mail: [email protected]
Subject to technical changes.
ISH3030-0140 UK 2A
12 07/2013
Adjust the volume
Each adjustable in 8 steps volume voice
Turn the volume control of the ring tone when a voice communication is established
(adjustment ex works: volume step 6 from 8) volume ring tone Turn the volume control for ring tone when the handset is hooked on (no voice communication)
(adjustment ex works: volume step 7 from 8)
A signal tone is reflecting the adjusted volume when turning the volume control of the ring tone.
If the setting is finished, the adjusted ring tone will be reflected in the adjusted volume.
Configuration options
function
ring tone volume voice volume selecting ring tones for door calls, internal calls and floor calls ring tone for door call 2 parallel allocation change audio AS limit block ring tone output block ring tone selection reset to factory settings
manual x x x x
–
–
–
–
TCSK-01
–
–
–
– x
–
–
– configo
TM
from version 1.3.3
x x x x x x
– x x
Programming with the Service Device TCSK-01
The indoor station is acting like a telephone.
Use the commands
„8“ for configuration (see product information Service Device TCSK-
01). search telephones activate parallel call deactivate parallel call
Ser. No. =the serial number of the new indoor station, that should be configured
ParSNo. =the serial number of the indoor station, to which the new configured indoor station is allocated
TCS TürControlSysteme AG
Mail: [email protected]
Subject to technical changes.
ISH3030-0140 UK 2A
07/2013 13
General information on the conduit in TCS audio systems
The conduit is determined by structural conditions and is only limited by ist length.
Note when selecting the cables: the loop resistance can amount max. 20
Ω (table)
In compliance to the max. permitted loop resistance the wire cross-section can be doubled, that means, that for one wire two lines can be used. The lines have to be twisted.
In case of using shielded cables: connect the shielding with each other and put it one-sided on mass (b-wire) in the power supply
Optional strand or star formed wiring table: loop resistances
cable length in m
70
80
90
100
150
10
20
30
40
50
60
200
250
300
Principle loop resistance
None of these devices (AS, IS or FE) should be located more than 20 Ohm away from the power supply and control unit (VS).
1.28
2.55
3.83
5.10
6.38
7.65
8.93
10.20
11.48
12.76
19.13
25.51
31.89
38.27
0.6 mm line diameter
loop resistance in Ω
0.71
0.8 mm
1.43
2.14
2.86
3.57
4.29
5.00
5.71
6.43
7.14
10.71
14.29
17.86
21.43
Resistance measurement
Switch off 230 V / 50 Hz of the VS.
Install a-b short-circuit at VS.
Other devices don’t disturb the measurement, they can be connected.
Measure the resistance at a/b of the last IS or AS.
TCS TürControlSysteme AG
Mail: [email protected]
Subject to technical changes.
ISH3030-0140 UK 2A
14 07/2013 a, b hier kurzschließen
20 Ohm: max. 160 m distance AS/IS-VS at 0.6 mm diameter max. 300 m distance AS/IS-VS at 0.8 mm diameter
AS front-door station
VS power supply and control unit
IS indoor station
FE
extended function
Repair
Error detection and indication
Errors will be indicated optical and acoustic: error tone for one time and constant flashing of the operation indication. When pressing any button, the error tone sounds again. The optical error indication stays active as long as the error is resolved.
error causes display error mode error tone elimination
a- and P-wire interchanged or short-circuited change a- and P-wire or eliminate short-circuit, device is going into sleep mode again a-wire: not connected or not supplied button stucks
(pressed longer than 15 s) both
LEDs are flashing
Connect the a-wire or proof power supply, device is going into sleep mode again
Remove button at the device or floor push button, device is going into sleep mode again
Substitution of an indoor station
– programming bell buttons
Basic principle
All devices at the TCS:BUS got an unique serial number.
Programming a bell button means that the serial number of an indoor station is allocated to the bell button of a front-door station and is stored within the EEPROM of the front-door station.
Ensure that the new indoor station is connected to the TCS:BUS and the mains voltage is switched on (the operation LED at the power supply and control unit is ON) and further, that the access to the flat is guaranteed during the programming.
This instruction describes the case, when a serial number is allocated to a bell button and no programming lock is set. To unlock a programming lock you need a Service Device TCSK-01or the configuration software configo
™.
TCS TürControlSysteme AG
Mail: [email protected]
Subject to technical changes.
ISH3030-0140 UK 2A
07/2013 15
1 initiate
Press shortly
2
LED blinks
Delete a button
Programming mode of the system is ON
◄6s►
Press until a delete tone sounds after 6 sec
1)
3 Programming via voice coummunication
oder establish voice communication to the front-door station
2)
4
press button shortly..
End programming
... until a ring tone sounds at the frontdoor and indoor station
1)
Press shortly LED is ON
Programming mode of the system is OFF *
)
*)
1) If there sounds a Progsperr tone instead, the front-door station got a promgramming lock.
The programming lock can be unlocked only with the Service Device TCSK-01 or the configuration software configo™
2) New developed front-door stations (from 2009 on) respond to that with a positive acknowledgement, if the serial number of the indoor station was received (see product information of the front-door station). device-specific indication modes of the front-door stations see product information of the front-door station
Cleaning
!
Avoid water from entering the device!
Do not use any abrasive detergents!
Clean the device with a dry or slightly wet cloth.
Remove stronger stains with a standard plastic cleaner.
TCS TürControlSysteme AG
Mail: [email protected]
Subject to technical changes.
ISH3030-0140 UK 2A
16 07/2013
Conformity
Download declarations of conformity for the device from www.tcsag.de, downloads, trade information.
Information on disposal
The adjoining symbol shows, that the device has to be disposed separately from domestic waste. The materials used are recyclable. Please do help protecting our environment and dispose the device via a collection point for electronic scrap.
Dispose the parts of the packaging in collecting tanks for cardboard and paper resp. plastics.
Warranty
We offer a simplified processing in case of warranty for electrician.
Note our conditions of sale and delivery, download from www.tcsag.de, downloads, trade information and included in our actually price list.
Please contact us: [email protected].
Service
Please send your questions and inquiries to
[email protected]
headquarters
TCS TürControlSysteme AG, Geschwister-Scholl-Str. 7, 39307 Genthin | Germany
Tel.: +49 (0) 3933/879910, FAX: +49 (0) 3933/879911, www.tcsag.de
TCS TürControlSysteme AG
Mail: [email protected]
Subject to technical changes.
ISH3030-0140 UK 2A
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 3 Scope of delivery
- 3 Safety instructions
- 3 Intended use
- 3 max. number ISH3030 in 2-wire operation
- 4 max. number ISH3030 in 3-wire operation
- 4 Indication and operating elements
- 5 Device overview
- 5 Technical data
- 6 Short description
- 6 Installation
- 6 Install the lower cover
- 7 Connecting the lines (2-wire technique)
- 7 See wiring example on page
- 7 Snapping-on the upper cover
- 7 Connect the handset
- 8 Open the device
- 8 Installation of extended functions
- 9 Connecting the lines
- 9 Connecting lines
- 9 Wiring diagram
- 10 Connection diagram 2-wire technique
- 10 Connection diagram 3-wire technique
- 10 Replacing an ISH1030 or TTS1 by an ISH
- 10 Commissioning
- 10 Settings
- 10 Pre-adjusted times
- 11 2-wire/3-wire operation
- 11 Ring tone selection
- 12 Adjust the volume
- 12 Configuration options
- 12 Programming with the Service Device TCSK
- 13 General to the conduit in TCS audio systems
- 13 Principle loop resistance
- 13 Resistance measurement
- 14 Repair
- 14 Error detection and indication
- 14 – programming bell buttons
- 15 Cleaning
- 16 Conformity
- 16 Information on disposal
- 16 Warranty
- 16 Service