Conteg RSF-27-60/100 racks Data Sheet


Add to my manuals

advertisement

Conteg RSF-27-60/100 racks Data Sheet | Manualzz

version: 27-05-2013

CONTEG DATASHEET

FREE-STANDING RACKS

PREMIUM Server RSF

CONTEG, spol. s r.o.

Czech Republic Headquarters:

Na Vítězné pláni 1719/4

140 00 Prague 4

Tel.: +420 261 219 182

Fax: +420 261 219 192

Production plant in the Czech Republic:

K Silu 2179

393 01 Pelhřimov

Tel.: +420 565 300 300

Fax: +420 565 533 955

All rights reserved, CONTEG © 2013

Local Branches/Offices

Austria:

Benelux:

Eastern Europe / Nordics:

France, Maghreb:

Germany / Switzerland /

Baltics / Denmark / Italy:

India:

Middle East:

Russia, CIS: [email protected]

www.conteg.com

+43 170 659 0115

+32 477 957 126

+49 172 8484 346

+33 686 074 386

+49 170 523 4958

+91 99 1695 0773

+971 4445 2838

+7 495 967 3840 www.conteg.com

1

PREMIUM Server RSF

The PREMIUM Server RSF rack is designed as a  pure server cabinet for data centers, equipment rooms and network or telecommunication closets. RSF’s  heavy-duty, all-welded design and 1 500  kg load rating mean that it’s  possible to accommodate the heavy equipment within a standard rack footprint. The RSF comes with a full range of doors, panels and locks. Available in various heights and depths, RSF is designed to work with Conteg’s airflow optimization solutions and flexible cable management systems, which means that RSF can be tailored to suit your needs. RSF can be used with many complementary systems (e.g. Intelligent Power PDUs – see appropriate data sheet), making your servers safe and secure.

COLOR SAMPLER:

RAL 9005 RAL 7035

PREMIUM

RSF‑42‑80/80

DESCRIPTION:

Sizes

• Height: 27, 42, 45, 48U

• Width: 600, 800 mm

• Depth: 800, 1 000, 1 200 mm (1 200 mm not available for 27U)

Construction

• Welded-frame design

• 1.5 & 2.0 mm sheet steel

Load rating

• 1 500 kg balanced load (1 000 kg for 27U only)

19" vertical extrusions

• 2 pairs of sliding 19" vertical L-type (600 mm) or P-type (800 mm) extrusions (Provide additional 12U of installation space – valid for racks 42U and taller), adjustable from inside

• Rear pair of vertical extrusions is divided in up to 3 parts (according to rack’s height) for individual settings according to server depth

IP rating

• Standard IP20

• IP40 when solid doors or panels applied

• Optionally up to IP54 with multipoint lock only

• A/C-ready – IP54 when A/C unit installed with multipoint lock only

Colors

• Standard RAL 7035 and 9 005

• Optionally other colors

Front door

• Vented door – perforation rate 83%

• Swivel handle lock – DIN profile, universal key 333, multipoint; optionally half profile cylinder or combination lock single or multipoint (other locks on request)

• Door opening angle 180°

• Easy re-hanging to open on right or left

• Optionally glass, steel, perforated, glass with perforation, vertically divided door

Rear door

• Vented door – perforation rate 83%

• Swivel handle lock – DIN profile, universal key 333, multipoint; optionally half profile cylinder or combination lock single or multipoint (other locks on request)

• Optionally can be replaced by full range of front doors and panels

Side panels

• Removable with locks

Top plate

• Single-piece design, removable

• 4" (100 mm) rounded cable entry in every corner covered by plastic cap

• 300×100 mm cable entries covered with removable sheet steel blank panels

Bottom plate

• Segmented design, removable

• 4" (100 mm) rounded cable entry in every corner covered by plastic caps

• 300×100 mm cable entries covered with removable sheets steel blank panels

Feet

• Adjustable feet as standard; plinth or plinth with filter options

Adaptation

• Possibility to adapt for installation of 21" equipment (on request only for 800 mm width)

• Adaptor DP-RE-01 needed (ordered separately)

Other

• Racks can be installed in blocks by using

DP-DR-UNI (ordered separately)

• CoolTeg and CoolSpot cooling units compatible – see appropriate data sheet for details

• GND/earthing kit included

All rights reserved, CONTEG © 2013 www.conteg.com

2

13 14 15 16 17 18 19 1 20 21

12

4

22 23 24

13 14

13

15

14

16

15

17

16

18

17

19

18

1

19

20

1

21

20 21

2

6

26

27

9

10

11

5

13 14 15 16 17 18 19 1 20 21

12

4

12

4

12

29

27

25

4

29

27

25

22 23 24

22 23 24

7

30

9

30

9

7

3

8

28

R

LY

EC

OM

MENDED

EQ

U

IP

EN

HI

G

T

22 23 24

STANDARD EQUIPMENT

1

2

3

2

Front and rear vented door 83% with multipoint swivel handle lock

2 pairs of 19" sliding extrusions

Holders for vertical extrusions

6

7

4

5

1 pair of side panels with lock

Adjustable feet

Frame of rack

8

9

-

GND/earthing kit

28 mounting kits

-

OPTIONAL EQUIPMENT (EXAMPLES)

10

11

12

13

Removable segmented bottom plate set (consists of C and F-design plates, may differ for other rack footprints) with cable entry openings

Plastic caps and blank panels for cable entry openings

Plinth

Plinth with filter

Vertically divided glass door 1,2

27

1,2

26

27

28

29

30

18

19

20

21

22

23

24

25

14

15

16

17

Vertically divided vented door 83% 2

Vertically divided perforated sheet steel door 2

11

2

Glass door

Glass door with side perforation

5

Perforated sheet steel door

Sheet steel door

Rear panel with module

Rear panel – 1 piece

Rear panel – perforated

Removable B-design top plate with cable entry and ventilation openings

Removable segmented bottom plate set (consists of B and G-design plates, may differ for other rack footprints) with cable entry and ventilation openings

Rounded cable grommet with brush

Blank panels for ventilation openings

Ventilation unit

Connecting kit with filter for ventilation unit

1 not available for 600 mm wide racks

2 requires multipoint lock www.conteg.com

All rights reserved, CONTEG © 2013

28

3

8

3

29

27

25

29

27

25

2

2

6

6

26

27

9

10

11

5

26

27

9

10

11

5

30

9

30

9

7

7

3

3

8

8

28

28

Bottom view

Rear view Side view Front view

600×800

Top plates – F design

600×1 000 600×1 200

800×800 800×1 000 800×1 200

800 depth

Top view

Bottom plates

BFB, 600×800 BHB, 600×1 000 BFFB, 600×1 200

Rear view

Bottom view

Side view Front view

CFC, 800×800 CHC, 800×1 000 CFFC, 800×1 200

600 depth

Top view

Cable entries – racks 800×800, 800×1 000 mm

• 5 openings (300×100 mm) in both top and bottom plates

• 4 openings 4”(100 mm) in both top and bottom plates

Cable entries – racks 800×1 200 mm

• 8 openings (300×100 mm) in both top and bottom plates

• 4 openings 4" (100 mm) in both top and bottom plates

Cable entries – racks 600×800, 600×1 000 mm

• 2 openings (300×100 mm) in both top and bottom plates

• 4 openings 4”(100 mm) in both top and bottom plates

All rights reserved, CONTEG © 2013

Cable entries – racks 600×1 200 mm

• 4 openings (300×100 mm) in both, top and bottom, plates

• 4 openings, 4"(100 mm) in both top and bottom plates

All cable entries are covered by blanking panels or plastic caps.

An individual plates can be defined – go to last page .

Note: All dimensions in mm www.conteg.com

4

5.

6.

7.

3.

4.

2.

/

-

-

1.

-

R

S

F

10.

11.

12.

-

13.

8.

9.

-

ORDERING AND SHIPPING INFORMATION: Configure the rack that will meet your requirements. The ordering matrix below will help you in creating the part number. As soon as you have the part number, please contact your Conteg products distributor.

Please note, that all RSF RACKS ARE DELIVERED FULLY ASSEMBLED and palletized!

FOLLOW THE STEPS TO SET UP THE DESIRED RSF RACK PRODUCT CODE!

HEIGHT

Code

1

2

27

42

45

48

WIDTH

Code

60

80

DEPTH

Code

3

8

10

12

Height in U

27

42

45

48

Width in mm

600

800

Depth in mm

800

1 000

1 200

External height in mm

1 311

1 978

2 111

2 245

Useful depth in mm

790

990

1 190

4

11

EXTRUSIONS

Code Front pair

T L

U

PLATES 1

Code

A

C

E

F

X

5

FRONT DOOR

Code Note

0

G

Without door

Glass door

1

S

P

T

W

A

B

C

D

F

Sheet steel door

Perforated sheet steel door 2

Glass door with side perforation 3

Vented door (perforation rate 83%)

Vertically divided glass door 4 *

Vertically divided glass door with side perforation 6 *

Vertically divided sheet steel door

Other

4

5

Vertically divided perforated sheet steel door 5

Vertically divided vented door (perforation rate 83%) 5

1 no IP protection

2 IP20 max.

3 IP30 max.

4 multipoint lock only

5

6

*

multipoint lock only, IP20 max.

multipoint lock only, IP30 max.

these options apply for RSF 800 only

P

Top plate

B no top

F

F no top 3

Rear pair Note

L divided

P divided

L-type extrusions, rear pair divided – for racks 600 mm wide only

P-type extrusions, rear pair divided – for racks 800 mm wide only, each extrusion with up to 3 additional 19" vertical positions (for 27U only 2 positions), blank panels not included

Bottom plate Note

Z

Z

XXX/XXXX 2 Standard – one piece top plate, segmented bottom plate no bottom 3 Open bottom – ready for installation on raised floor or plinth no bottom 3 Open top and bottom, for individual plates

1 For more information on plates go to last page

2

3

600×800: BFB, 600×1 000: BHB, 600×1 200: BFFB, 800×800: CFC, 800×1 000: CHC, 800×1 200: CFFC

Open top or bottom results in no IP protection unless otherwise stated

1

2

3

4

7

Top and bottom single piece plates, required for IP54

Open top – for A/C-ready option (table 10)

B

C

W

A

D

F

REAR DOOR / PANEL

Code Note

0

G

S

Without panel/door 1

Glass door

P

T

Sheet steel door

Perforated sheet steel door 2

Glass door with side perforation 3

Vented door (perforation rate 83%)

Vertically divided glass door 4 *

Vertically divided sheet steel door 4

5

Vertically divided glass door with side perforation 6

Vertically divided perforated sheet steel door 5

*

Vertically divided vented door (perforation rate 83%) 5

Y

R

Z

Rear panel – single piece

Perforated rear panel – single piece

Other

7

Rear panel – divided, with cable entry

8

7 no IP protection

IP20 max.

IP30 max.

multipoint lock only

5 multipoint lock only, IP20 max.

6 multipoint lock only, IP30 max.

7 Lock code or X only

8 Lock code or X only, IP20 max.

* these options apply for RSF 800 only

6

J

I

G

H

K

L

FRONT DOOR LOCK

Code Options

1

3

Swivel handle with electronic lock, universal key

Swivel handle with electronic lock, universal key, multipoint

E

F

Swivel handle with combination lock and universal key

Swivel handle with combination lock and universal key, multipoint

Swivel handle with combination lock, keyed different

Swivel handle with combination lock, keyed different, multipoint

Swivel handle with profile half cylinder, universal key

Swivel handle with profile half cylinder, universal key, multipoint

V

W

Swivel handle with profile half cylinder, keyed different

Swivel handle with profile half cylinder, keyed different, multipoint

Swivel handle DIN profile, universal key, 333

Swivel handle DIN profile, universal key, 333, multipoint

Other

10

IP RATING 1

Code Note

0

2

3

4

IP00

IP20

IP30

IP40

5

A

IP54 3

A/C ready 2

1 According to EN 60 529

2 Ready for A/C unit installation; recommended when cooling is planned or required; IP54 when A/C unit installed

3 according to instructions

Multipoint lock only

8

REAR DOOR / PANEL LOCK

Code Options

1

3

E

F

G

H

I

J

Swivel handle with electronic lock, universal key

Swivel handle with electronic lock, universal key, multipoint

Swivel handle with combination lock and universal key

Swivel handle with combination lock and universal key, multipoint

Swivel handle with combination lock, keyed different

Swivel handle with combination lock, keyed different, multipoint

Swivel handle with profile half cylinder, universal key

K

L

Swivel handle with profile half cylinder, universal key, multipoint

Swivel handle with profile half cylinder, keyed different

Swivel handle with profile half cylinder, keyed different, multipoint

V

W

U

X

Swivel handle DIN profile, universal key, 333

Swivel handle DIN profile, universal key, 333, multipoint

Lock for rear panel, universal key

Lock for rear panel, keyed different

Other

12

LOAD RATING

Code

A

Load rate in kg

1 000

F 1 500

Note

27U only

Balanced load

13

COLOR

Code Note

B

H

RAL 7035 (light gray)

RAL 9005 (black)

An example of a correct product code

RSF-48-80/12U-WWFWA-2EF-B

9

SIDE PANELS (BOTH SIDES) *

Code Note

0

A

B

C

D

E

F

G

H

No side panels

2 side panels, sheet steel, universal key

1 side panel, sheet steel, universal key

2 side panels, sheet steel, individual key

1 side panel, sheet steel, individual key

2 side panels, sheet steel with perforation, universal key

1 side panel, sheet steel with perforation, universal key

2 side panels, sheet steel with perforation, individual key

1 side panel, sheet steel with perforation, individual key

Other

* open side / sides results in no IP protection; side panels with perforation result in protection rating IP20 max.

www.conteg.com

All rights reserved, CONTEG © 2013

5

Code

RSF-27-60/80

RSF-42-60/80

RSF-45-60/80

RSF-48-60/80

RSF-27-60/100

RSF-42-60/100

RSF-45-60/100

RSF-48-60/100

RSF-42-60/120

RSF-45-60/120

RSF-48-60/120

RSF-27-80/80

RSF-42-80/80

RSF-45-80/80

RSF-48-80/80

RSF-27-80/100

RSF-42-80/100

RSF-45-80/100

RSF-48-80/100

RSF-42-80/120

RSF-45-80/120

RSF-48-80/120

H in U

45

48

42

45

48

42

45

48

45

48

27

27

42

27

42

45

48

42

27

42

45

48

Load rating in kg

1 500

1 500

1 500

1 500

1 500

1 500

1 500

1 000

1 500

1 500

1 500

1 000

1 500

1 000

1 500

1 500

1 500

1 000

1 500

1 500

1 500

1 500

2 111

2 245

1 978

2 111

2 245

2 111

2 245

1 311

1 978

2 111

2 245

1 311

1 978

H *

1 311

1 978

2 111

2 245

1 311

1 978

2 111

2 245

1 978

800

800

800

800

800

600

600

800

800

800

800

800

800

600

600

600

600

600

600

600

Dimensions in mm

W D Useful depth

600

600

800

800

790

790

800

800

1 000

1 000

1 000

1 000

1 200

790

790

990

990

990

990

1 190

1 200

1 200

800

800

800

800

1 000

1 000

1 000

1 000

1 200

1 200

1 200

990

990

1 190

1 190

1 190

1 190

1 190

790

790

790

790

990

990

2 290

2 430

2 160

2 290

2 430

2 290

2 430

1 500

2 160

2 290

2 430

1 500

2 160

Dimensions incl. packing in mm

H W D

1 500

2 160

640

640

840

840

2 290

2 430

1 500

2 160

2 290

2 430

2 160

640

640

640

640

640

640

640

840

840

1 040

1 040

1 040

1 040

1 240

640

640

840

840

840

840

840

840

840

840

840

840

840

1 040

1 040

1 240

1 240

1 240

1 240

1 240

840

840

840

840

1 040

1 040

Gross weight in kg

165

173

175

198

208

170

178

100

134

141

147

124

157

109

135

142

148

149

85

112

119

123

* Height in mm without feet; for feet add 16‑45 mm

PREMIUM RACK SERIES PLATES

PREMIUM rack series gives you unlimited flexibility when planning the final look of your rack, thanks to the interchangeable top and bottom plates. A portfolio of three different single-piece top plates and an even wider range of segmented bottom plates represent a unique interface between out-of-rack and in-rack cabling systems (like OptiWay, Top Ducts and High

Density Wire Managers). Simply choose the plate design (quantity and type of cable entry openings) that perfectly suits to your needs. All presented plates here are applicable for RHF, RSF and RDF rack series.

TOP PLATES

Top plates are designed as singlepieces with three different design options. They are delivered already installed or separately in a carton box. The plate is always delivered with blanking panels/plastic caps.

Installation in the rack

Code *

RHF/RDF/RSF footprint in mm

CO-TI-60/80-X-Y 600×800

CO-TI-60/100-X-Y 600×1 000

CO-TI-60/120-X-Y 600×1 200

CO-TI-80/80-X-Y 800×800

CO-TI-80/100-X-Y 800×1 000

CO-TI-80/120-X-Y 800×1 200

* To be ordered together with rack that you want to have plate installed in

600×800

B design

800×800

600×1 000 800×1 000

600×800

F design

800×800

600×1 000 800×1 000

600×800

I design

800×800

600×1 000 800×1 000

Choose the design you like and write its code (B, I, F or Z) instead of X. Write B for gray (RAL 7035) or

H for black (RAL 9005) instead of Y.

Delivery in carton box

Code

RHF/RDF/RSF footprint in mm

CO-TU-60/80-X-Y 600×800

CO-TU-60/100-X-Y 600×1 000

CO-TU-60/120-X-Y 600×1 200

CO-TU-80/80-X-Y 800×800

CO-TU-80/100-X-Y 800×1 000

CO-TU-80/120-X-Y 800×1 200

Choose the design you like and write its code (B, I, F or Z) instead of X. Write B for gray (RAL 7035) or

H for black (RAL 9005) instead of Y.

600×1 200 800×1 200 600×1 200

B and Z design are compatible with request with IP54

800×1 200 600×1 200 800×1 200 www.conteg.com

All rights reserved, CONTEG © 2013

6

BOTTOM PLATES

Bottom plates are designed as segmented. Full bottom plate

(set) consists of 3 or 4 plates. They are delivered already installed or separately in a  carton box. Plate is always delivered with blanking panels/plastic caps.

A design *

B design

600 mm 800 mm

C design

N/A

Installation in the rack

Code *

RHF/RDF/

RSF footprint in mm

CO-BI-60/80-XXX-Y 600×800

CO-BI-60/100-XXX-Y 600×1 000

CO-BI-60/120-XXXX-Y 600×1 200

CO-BI-80/80-XXX-Y 800×800

CO-BI-80/100-XXX-Y 800×1 000

CO-BI-80/120-XXXX-Y 800×1 200

* To be ordered together with rack that you want to have the plate installed in

Define the desired bottom plate set. Choose the design of plates you like and write its codes (A – I)

in front to rear order instead of

X. Write B for gray (RAL 7035) or

H for black (RAL 9005) instead of Y. Any plate may be omitted

(incomplete bottom plate sets applicable – results in no IP protection). Write 0 if the position should be left empty.

Delivery in carton box

Code

RHF/RDF/RSF width in mm

CO-BU-60-X-Y 600

CO-BU-80-X-Y 800

Single plates can be delivered in carton boxes. Choose the design you like and write its code (A – I) instead of X. Write B for gray (RAL

7035) or H for black (RAL 9005) instead of Y.

D design

E design

F design

G design

H design

I design

* plate is designed as divided with double brush

600×800

600×1 000

Z design

800×800

800×1 000

C (front)

F

C (rear)

D (front)

B (rear)

I

Example

CO-BI-80/80-CFC-X installed in rack

Example

CO-BI-80/100-DIB-X installed in rack

G

Example

CO-BU-80-G-X delivered in carton box

Example

CO-BI-80/120-AFFA-X installed in rack

A (front)

F

F

A (rear)

A, B, C, D, E design: lateral plates

Complete bottom plate always contains two plates of A, B, C, D or E design. Combination of two different plates is allowed.

F, G design: central plates for 800 and

1 200 mm deep racks

Complete bottom plate always contains one

(800  mm deep racks) or two (1 200  mm deep racks) plates of F or G design. Combination of two different plates is allowed.

H, I design: central plates for 1 000 mm deep racks

Complete bottom cover always contains always one plate of H or I design.

RECOMMENDED ACCESSORIES

FOR PREMIUM PLATE CABLE ENTRIES

All cable entries are delivered with removable blanking panels or plastic caps.

If removed, open cable entries result in no IP rating so water or dust can enter the rack. Sharp edges and poor management of entering cables can also negatively impact the service life of cables and their performance in data transmission. With products from the portfolio “cable protection in cable openings” both problems can be prevented. For more information on those products see appropriate data sheet.

600×1 200 800×1 200

300×100 mm

Cable entry openings, covered by removable sheet steel blank panel

Recommended accessories

Code

DP-KP-LEM

DP-KP-HCE

DP-KP-KAR

DP-KP-KAR4

DP-KP-KAR4-D

DP-KP-KAR7

300×50 mm

Cable entry openings, covered by removable sheet steel blank panel

Recommended accessories

Code

DP-KP-KAR5

4" (100 mm)

Cable entry openings, covered by removable plastic cap

Recommended accessories

Code

DP-KP-RB4

Dimensions of brush openings: width 60 – 76×400 mm width 80 – 76 x600 mm

Brush dimensions: width 60 – 60×400 mm width 80 – 60×600 mm

420×280 mm

Ventilation unit openings, covered by removable sheet steel blank panel, allows for installation of

6-fan unit

420×440 mm

Ventilation unit openings, covered by removable sheet steel blank panel, allows for installation of

9-fan unit

Example of installed plates and cable opening in a rack

These openings are used for the installation of ventila‑ tion unit. For more information on ventilation units and related products see appropriate data sheet www.conteg.com

All rights reserved, CONTEG © 2013

7

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement