- Computers & electronics
- Computer components
- Chassis components
- Racks
- Conteg
- RSF-27-60/100
- Data Sheet
advertisement
version: 27-05-2013
CONTEG DATASHEET
FREE-STANDING RACKS
PREMIUM Server RSF
CONTEG, spol. s r.o.
Czech Republic Headquarters:
Na Vítězné pláni 1719/4
140 00 Prague 4
Tel.: +420 261 219 182
Fax: +420 261 219 192
Production plant in the Czech Republic:
K Silu 2179
393 01 Pelhřimov
Tel.: +420 565 300 300
Fax: +420 565 533 955
All rights reserved, CONTEG © 2013
Local Branches/Offices
Austria:
Benelux:
Eastern Europe / Nordics:
France, Maghreb:
Germany / Switzerland /
Baltics / Denmark / Italy:
India:
Middle East:
Russia, CIS: [email protected]
www.conteg.com
+43 170 659 0115
+32 477 957 126
+49 172 8484 346
+33 686 074 386
+49 170 523 4958
+91 99 1695 0773
+971 4445 2838
+7 495 967 3840 www.conteg.com
1
PREMIUM Server RSF
The PREMIUM Server RSF rack is designed as a pure server cabinet for data centers, equipment rooms and network or telecommunication closets. RSF’s heavy-duty, all-welded design and 1 500 kg load rating mean that it’s possible to accommodate the heavy equipment within a standard rack footprint. The RSF comes with a full range of doors, panels and locks. Available in various heights and depths, RSF is designed to work with Conteg’s airflow optimization solutions and flexible cable management systems, which means that RSF can be tailored to suit your needs. RSF can be used with many complementary systems (e.g. Intelligent Power PDUs – see appropriate data sheet), making your servers safe and secure.
COLOR SAMPLER:
RAL 9005 RAL 7035
PREMIUM
RSF‑42‑80/80
DESCRIPTION:
Sizes
• Height: 27, 42, 45, 48U
• Width: 600, 800 mm
• Depth: 800, 1 000, 1 200 mm (1 200 mm not available for 27U)
Construction
• Welded-frame design
• 1.5 & 2.0 mm sheet steel
Load rating
• 1 500 kg balanced load (1 000 kg for 27U only)
19" vertical extrusions
• 2 pairs of sliding 19" vertical L-type (600 mm) or P-type (800 mm) extrusions (Provide additional 12U of installation space – valid for racks 42U and taller), adjustable from inside
• Rear pair of vertical extrusions is divided in up to 3 parts (according to rack’s height) for individual settings according to server depth
IP rating
• Standard IP20
• IP40 when solid doors or panels applied
• Optionally up to IP54 with multipoint lock only
• A/C-ready – IP54 when A/C unit installed with multipoint lock only
Colors
• Standard RAL 7035 and 9 005
• Optionally other colors
Front door
• Vented door – perforation rate 83%
• Swivel handle lock – DIN profile, universal key 333, multipoint; optionally half profile cylinder or combination lock single or multipoint (other locks on request)
• Door opening angle 180°
• Easy re-hanging to open on right or left
• Optionally glass, steel, perforated, glass with perforation, vertically divided door
Rear door
• Vented door – perforation rate 83%
• Swivel handle lock – DIN profile, universal key 333, multipoint; optionally half profile cylinder or combination lock single or multipoint (other locks on request)
• Optionally can be replaced by full range of front doors and panels
Side panels
• Removable with locks
Top plate
• Single-piece design, removable
• 4" (100 mm) rounded cable entry in every corner covered by plastic cap
• 300×100 mm cable entries covered with removable sheet steel blank panels
Bottom plate
• Segmented design, removable
• 4" (100 mm) rounded cable entry in every corner covered by plastic caps
• 300×100 mm cable entries covered with removable sheets steel blank panels
Feet
• Adjustable feet as standard; plinth or plinth with filter options
Adaptation
• Possibility to adapt for installation of 21" equipment (on request only for 800 mm width)
• Adaptor DP-RE-01 needed (ordered separately)
Other
• Racks can be installed in blocks by using
DP-DR-UNI (ordered separately)
• CoolTeg and CoolSpot cooling units compatible – see appropriate data sheet for details
• GND/earthing kit included
All rights reserved, CONTEG © 2013 www.conteg.com
2
13 14 15 16 17 18 19 1 20 21
12
4
22 23 24
13 14
13
15
14
16
15
17
16
18
17
19
18
1
19
20
1
21
20 21
2
6
26
27
9
10
11
5
13 14 15 16 17 18 19 1 20 21
12
4
12
4
12
29
27
25
4
29
27
25
22 23 24
22 23 24
7
30
9
30
9
7
3
8
28
R
LY
EC
OM
MENDED
EQ
U
IP
EN
HI
G
T
22 23 24
STANDARD EQUIPMENT
1
2
3
2
Front and rear vented door 83% with multipoint swivel handle lock
2 pairs of 19" sliding extrusions
Holders for vertical extrusions
6
7
4
5
1 pair of side panels with lock
Adjustable feet
Frame of rack
8
9
-
GND/earthing kit
28 mounting kits
-
OPTIONAL EQUIPMENT (EXAMPLES)
10
11
12
13
Removable segmented bottom plate set (consists of C and F-design plates, may differ for other rack footprints) with cable entry openings
Plastic caps and blank panels for cable entry openings
Plinth
Plinth with filter
Vertically divided glass door 1,2
27
1,2
26
27
28
29
30
18
19
20
21
22
23
24
25
14
15
16
17
Vertically divided vented door 83% 2
Vertically divided perforated sheet steel door 2
11
2
Glass door
Glass door with side perforation
5
Perforated sheet steel door
Sheet steel door
Rear panel with module
Rear panel – 1 piece
Rear panel – perforated
Removable B-design top plate with cable entry and ventilation openings
Removable segmented bottom plate set (consists of B and G-design plates, may differ for other rack footprints) with cable entry and ventilation openings
Rounded cable grommet with brush
Blank panels for ventilation openings
Ventilation unit
Connecting kit with filter for ventilation unit
1 not available for 600 mm wide racks
2 requires multipoint lock www.conteg.com
All rights reserved, CONTEG © 2013
28
3
8
3
29
27
25
29
27
25
2
2
6
6
26
27
9
10
11
5
26
27
9
10
11
5
30
9
30
9
7
7
3
3
8
8
28
28
Bottom view
Rear view Side view Front view
600×800
Top plates – F design
600×1 000 600×1 200
800×800 800×1 000 800×1 200
800 depth
Top view
Bottom plates
BFB, 600×800 BHB, 600×1 000 BFFB, 600×1 200
Rear view
Bottom view
Side view Front view
CFC, 800×800 CHC, 800×1 000 CFFC, 800×1 200
600 depth
Top view
Cable entries – racks 800×800, 800×1 000 mm
• 5 openings (300×100 mm) in both top and bottom plates
• 4 openings 4”(100 mm) in both top and bottom plates
Cable entries – racks 800×1 200 mm
• 8 openings (300×100 mm) in both top and bottom plates
• 4 openings 4" (100 mm) in both top and bottom plates
Cable entries – racks 600×800, 600×1 000 mm
• 2 openings (300×100 mm) in both top and bottom plates
• 4 openings 4”(100 mm) in both top and bottom plates
All rights reserved, CONTEG © 2013
Cable entries – racks 600×1 200 mm
• 4 openings (300×100 mm) in both, top and bottom, plates
• 4 openings, 4"(100 mm) in both top and bottom plates
All cable entries are covered by blanking panels or plastic caps.
An individual plates can be defined – go to last page .
Note: All dimensions in mm www.conteg.com
4
5.
6.
7.
3.
4.
2.
/
-
-
1.
-
R
S
F
10.
11.
12.
-
13.
8.
9.
-
ORDERING AND SHIPPING INFORMATION: Configure the rack that will meet your requirements. The ordering matrix below will help you in creating the part number. As soon as you have the part number, please contact your Conteg products distributor.
Please note, that all RSF RACKS ARE DELIVERED FULLY ASSEMBLED and palletized!
FOLLOW THE STEPS TO SET UP THE DESIRED RSF RACK PRODUCT CODE!
HEIGHT
Code
1
2
27
42
45
48
WIDTH
Code
60
80
DEPTH
Code
3
8
10
12
Height in U
27
42
45
48
Width in mm
600
800
Depth in mm
800
1 000
1 200
External height in mm
1 311
1 978
2 111
2 245
Useful depth in mm
790
990
1 190
4
11
EXTRUSIONS
Code Front pair
T L
U
PLATES 1
Code
A
C
E
F
X
5
FRONT DOOR
Code Note
0
G
Without door
Glass door
1
S
P
T
W
A
B
C
D
F
Sheet steel door
Perforated sheet steel door 2
Glass door with side perforation 3
Vented door (perforation rate 83%)
Vertically divided glass door 4 *
Vertically divided glass door with side perforation 6 *
Vertically divided sheet steel door
Other
4
5
Vertically divided perforated sheet steel door 5
Vertically divided vented door (perforation rate 83%) 5
1 no IP protection
2 IP20 max.
3 IP30 max.
4 multipoint lock only
5
6
*
multipoint lock only, IP20 max.
multipoint lock only, IP30 max.
these options apply for RSF 800 only
P
Top plate
B no top
F
F no top 3
Rear pair Note
L divided
P divided
L-type extrusions, rear pair divided – for racks 600 mm wide only
P-type extrusions, rear pair divided – for racks 800 mm wide only, each extrusion with up to 3 additional 19" vertical positions (for 27U only 2 positions), blank panels not included
Bottom plate Note
Z
Z
XXX/XXXX 2 Standard – one piece top plate, segmented bottom plate no bottom 3 Open bottom – ready for installation on raised floor or plinth no bottom 3 Open top and bottom, for individual plates
1 For more information on plates go to last page
2
3
600×800: BFB, 600×1 000: BHB, 600×1 200: BFFB, 800×800: CFC, 800×1 000: CHC, 800×1 200: CFFC
Open top or bottom results in no IP protection unless otherwise stated
1
2
3
4
7
Top and bottom single piece plates, required for IP54
Open top – for A/C-ready option (table 10)
B
C
W
A
D
F
REAR DOOR / PANEL
Code Note
0
G
S
Without panel/door 1
Glass door
P
T
Sheet steel door
Perforated sheet steel door 2
Glass door with side perforation 3
Vented door (perforation rate 83%)
Vertically divided glass door 4 *
Vertically divided sheet steel door 4
5
Vertically divided glass door with side perforation 6
Vertically divided perforated sheet steel door 5
*
Vertically divided vented door (perforation rate 83%) 5
Y
R
Z
Rear panel – single piece
Perforated rear panel – single piece
Other
7
Rear panel – divided, with cable entry
8
7 no IP protection
IP20 max.
IP30 max.
multipoint lock only
5 multipoint lock only, IP20 max.
6 multipoint lock only, IP30 max.
7 Lock code U or X only
8 Lock code U or X only, IP20 max.
* these options apply for RSF 800 only
6
J
I
G
H
K
L
FRONT DOOR LOCK
Code Options
1
3
Swivel handle with electronic lock, universal key
Swivel handle with electronic lock, universal key, multipoint
E
F
Swivel handle with combination lock and universal key
Swivel handle with combination lock and universal key, multipoint
Swivel handle with combination lock, keyed different
Swivel handle with combination lock, keyed different, multipoint
Swivel handle with profile half cylinder, universal key
Swivel handle with profile half cylinder, universal key, multipoint
V
W
Swivel handle with profile half cylinder, keyed different
Swivel handle with profile half cylinder, keyed different, multipoint
Swivel handle DIN profile, universal key, 333
Swivel handle DIN profile, universal key, 333, multipoint
Other
10
IP RATING 1
Code Note
0
2
3
4
IP00
IP20
IP30
IP40
5
A
IP54 3
A/C ready 2
1 According to EN 60 529
2 Ready for A/C unit installation; recommended when cooling is planned or required; IP54 when A/C unit installed
3 according to instructions
Multipoint lock only
8
REAR DOOR / PANEL LOCK
Code Options
1
3
E
F
G
H
I
J
Swivel handle with electronic lock, universal key
Swivel handle with electronic lock, universal key, multipoint
Swivel handle with combination lock and universal key
Swivel handle with combination lock and universal key, multipoint
Swivel handle with combination lock, keyed different
Swivel handle with combination lock, keyed different, multipoint
Swivel handle with profile half cylinder, universal key
K
L
Swivel handle with profile half cylinder, universal key, multipoint
Swivel handle with profile half cylinder, keyed different
Swivel handle with profile half cylinder, keyed different, multipoint
V
W
U
X
Swivel handle DIN profile, universal key, 333
Swivel handle DIN profile, universal key, 333, multipoint
Lock for rear panel, universal key
Lock for rear panel, keyed different
Other
12
LOAD RATING
Code
A
Load rate in kg
1 000
F 1 500
Note
27U only
Balanced load
13
COLOR
Code Note
B
H
RAL 7035 (light gray)
RAL 9005 (black)
An example of a correct product code
RSF-48-80/12U-WWFWA-2EF-B
9
SIDE PANELS (BOTH SIDES) *
Code Note
0
A
B
C
D
E
F
G
H
No side panels
2 side panels, sheet steel, universal key
1 side panel, sheet steel, universal key
2 side panels, sheet steel, individual key
1 side panel, sheet steel, individual key
2 side panels, sheet steel with perforation, universal key
1 side panel, sheet steel with perforation, universal key
2 side panels, sheet steel with perforation, individual key
1 side panel, sheet steel with perforation, individual key
Other
* open side / sides results in no IP protection; side panels with perforation result in protection rating IP20 max.
www.conteg.com
All rights reserved, CONTEG © 2013
5
Code
RSF-27-60/80
RSF-42-60/80
RSF-45-60/80
RSF-48-60/80
RSF-27-60/100
RSF-42-60/100
RSF-45-60/100
RSF-48-60/100
RSF-42-60/120
RSF-45-60/120
RSF-48-60/120
RSF-27-80/80
RSF-42-80/80
RSF-45-80/80
RSF-48-80/80
RSF-27-80/100
RSF-42-80/100
RSF-45-80/100
RSF-48-80/100
RSF-42-80/120
RSF-45-80/120
RSF-48-80/120
H in U
45
48
42
45
48
42
45
48
45
48
27
27
42
27
42
45
48
42
27
42
45
48
Load rating in kg
1 500
1 500
1 500
1 500
1 500
1 500
1 500
1 000
1 500
1 500
1 500
1 000
1 500
1 000
1 500
1 500
1 500
1 000
1 500
1 500
1 500
1 500
2 111
2 245
1 978
2 111
2 245
2 111
2 245
1 311
1 978
2 111
2 245
1 311
1 978
H *
1 311
1 978
2 111
2 245
1 311
1 978
2 111
2 245
1 978
800
800
800
800
800
600
600
800
800
800
800
800
800
600
600
600
600
600
600
600
Dimensions in mm
W D Useful depth
600
600
800
800
790
790
800
800
1 000
1 000
1 000
1 000
1 200
790
790
990
990
990
990
1 190
1 200
1 200
800
800
800
800
1 000
1 000
1 000
1 000
1 200
1 200
1 200
990
990
1 190
1 190
1 190
1 190
1 190
790
790
790
790
990
990
2 290
2 430
2 160
2 290
2 430
2 290
2 430
1 500
2 160
2 290
2 430
1 500
2 160
Dimensions incl. packing in mm
H W D
1 500
2 160
640
640
840
840
2 290
2 430
1 500
2 160
2 290
2 430
2 160
640
640
640
640
640
640
640
840
840
1 040
1 040
1 040
1 040
1 240
640
640
840
840
840
840
840
840
840
840
840
840
840
1 040
1 040
1 240
1 240
1 240
1 240
1 240
840
840
840
840
1 040
1 040
Gross weight in kg
165
173
175
198
208
170
178
100
134
141
147
124
157
109
135
142
148
149
85
112
119
123
* Height in mm without feet; for feet add 16‑45 mm
PREMIUM RACK SERIES PLATES
PREMIUM rack series gives you unlimited flexibility when planning the final look of your rack, thanks to the interchangeable top and bottom plates. A portfolio of three different single-piece top plates and an even wider range of segmented bottom plates represent a unique interface between out-of-rack and in-rack cabling systems (like OptiWay, Top Ducts and High
Density Wire Managers). Simply choose the plate design (quantity and type of cable entry openings) that perfectly suits to your needs. All presented plates here are applicable for RHF, RSF and RDF rack series.
TOP PLATES
Top plates are designed as singlepieces with three different design options. They are delivered already installed or separately in a carton box. The plate is always delivered with blanking panels/plastic caps.
Installation in the rack
Code *
RHF/RDF/RSF footprint in mm
CO-TI-60/80-X-Y 600×800
CO-TI-60/100-X-Y 600×1 000
CO-TI-60/120-X-Y 600×1 200
CO-TI-80/80-X-Y 800×800
CO-TI-80/100-X-Y 800×1 000
CO-TI-80/120-X-Y 800×1 200
* To be ordered together with rack that you want to have plate installed in
600×800
B design
800×800
600×1 000 800×1 000
600×800
F design
800×800
600×1 000 800×1 000
600×800
I design
800×800
600×1 000 800×1 000
Choose the design you like and write its code (B, I, F or Z) instead of X. Write B for gray (RAL 7035) or
H for black (RAL 9005) instead of Y.
Delivery in carton box
Code
RHF/RDF/RSF footprint in mm
CO-TU-60/80-X-Y 600×800
CO-TU-60/100-X-Y 600×1 000
CO-TU-60/120-X-Y 600×1 200
CO-TU-80/80-X-Y 800×800
CO-TU-80/100-X-Y 800×1 000
CO-TU-80/120-X-Y 800×1 200
Choose the design you like and write its code (B, I, F or Z) instead of X. Write B for gray (RAL 7035) or
H for black (RAL 9005) instead of Y.
600×1 200 800×1 200 600×1 200
B and Z design are compatible with request with IP54
800×1 200 600×1 200 800×1 200 www.conteg.com
All rights reserved, CONTEG © 2013
6
BOTTOM PLATES
Bottom plates are designed as segmented. Full bottom plate
(set) consists of 3 or 4 plates. They are delivered already installed or separately in a carton box. Plate is always delivered with blanking panels/plastic caps.
A design *
B design
600 mm 800 mm
C design
N/A
Installation in the rack
Code *
RHF/RDF/
RSF footprint in mm
CO-BI-60/80-XXX-Y 600×800
CO-BI-60/100-XXX-Y 600×1 000
CO-BI-60/120-XXXX-Y 600×1 200
CO-BI-80/80-XXX-Y 800×800
CO-BI-80/100-XXX-Y 800×1 000
CO-BI-80/120-XXXX-Y 800×1 200
* To be ordered together with rack that you want to have the plate installed in
Define the desired bottom plate set. Choose the design of plates you like and write its codes (A – I)
in front to rear order instead of
X. Write B for gray (RAL 7035) or
H for black (RAL 9005) instead of Y. Any plate may be omitted
(incomplete bottom plate sets applicable – results in no IP protection). Write 0 if the position should be left empty.
Delivery in carton box
Code
RHF/RDF/RSF width in mm
CO-BU-60-X-Y 600
CO-BU-80-X-Y 800
Single plates can be delivered in carton boxes. Choose the design you like and write its code (A – I) instead of X. Write B for gray (RAL
7035) or H for black (RAL 9005) instead of Y.
D design
E design
F design
G design
H design
I design
* plate is designed as divided with double brush
600×800
600×1 000
Z design
800×800
800×1 000
C (front)
F
C (rear)
D (front)
B (rear)
I
Example
CO-BI-80/80-CFC-X installed in rack
Example
CO-BI-80/100-DIB-X installed in rack
G
Example
CO-BU-80-G-X delivered in carton box
Example
CO-BI-80/120-AFFA-X installed in rack
A (front)
F
F
A (rear)
A, B, C, D, E design: lateral plates
Complete bottom plate always contains two plates of A, B, C, D or E design. Combination of two different plates is allowed.
F, G design: central plates for 800 and
1 200 mm deep racks
Complete bottom plate always contains one
(800 mm deep racks) or two (1 200 mm deep racks) plates of F or G design. Combination of two different plates is allowed.
H, I design: central plates for 1 000 mm deep racks
Complete bottom cover always contains always one plate of H or I design.
RECOMMENDED ACCESSORIES
FOR PREMIUM PLATE CABLE ENTRIES
All cable entries are delivered with removable blanking panels or plastic caps.
If removed, open cable entries result in no IP rating so water or dust can enter the rack. Sharp edges and poor management of entering cables can also negatively impact the service life of cables and their performance in data transmission. With products from the portfolio “cable protection in cable openings” both problems can be prevented. For more information on those products see appropriate data sheet.
600×1 200 800×1 200
300×100 mm
Cable entry openings, covered by removable sheet steel blank panel
Recommended accessories
Code
DP-KP-LEM
DP-KP-HCE
DP-KP-KAR
DP-KP-KAR4
DP-KP-KAR4-D
DP-KP-KAR7
300×50 mm
Cable entry openings, covered by removable sheet steel blank panel
Recommended accessories
Code
DP-KP-KAR5
4" (100 mm)
Cable entry openings, covered by removable plastic cap
Recommended accessories
Code
DP-KP-RB4
Dimensions of brush openings: width 60 – 76×400 mm width 80 – 76 x600 mm
Brush dimensions: width 60 – 60×400 mm width 80 – 60×600 mm
420×280 mm
Ventilation unit openings, covered by removable sheet steel blank panel, allows for installation of
6-fan unit
420×440 mm
Ventilation unit openings, covered by removable sheet steel blank panel, allows for installation of
9-fan unit
Example of installed plates and cable opening in a rack
These openings are used for the installation of ventila‑ tion unit. For more information on ventilation units and related products see appropriate data sheet www.conteg.com
All rights reserved, CONTEG © 2013
7
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement