Mitsubishi Electric MSZ-EF25VE2W air conditioner Datasheet
Mitsubishi Electric MSZ-EF25VE2W is a stylish wall-mounted air conditioner designed for modern interiors. It offers energy-efficient operation with high SEER and SCOP ratings, achieving A+++ for cooling and A++ for heating. The unit features a silent mode for quiet operation, reaching as low as 21dB. It also incorporates a low standby power function, reducing wasted energy consumption. The MSZ-EF25VE2W comes in three colors - white, silver, and black - to match any room décor.
Advertisement
Advertisement
29
SERIES
SELECTION
Choose the model that best matches room conditions.
STEP 1 SELECT SERIES
A multiple series line-up to choose from, each with various outstanding features. In addition to inverter-equipped models, constant-speed, floor-standing and cassette models can be selected. Choose the best series to match usage needs.
Wall-mounted Units
MSZ-F
SERIES
MSZ-E
SERIES
Super energysaving
25/35
SEER
A +++
25/35
SCOP
A +++
25/35
Ultra-quiet
Cooling
Heating
MSZ-S
SERIES
MSZ-G
SERIES
25/35 25/35
SEER
A +++
SCOP
A ++
Cooling
Heating
MSZ-H
SERIES
SEER
A ++
SCOP
A +
Cooling
Heating
Floor-standing
MFZ
SERIES
SEER
A ++
SCOP
A +
Cooling
Heating
Cassette Units
MLZ
SERIES
50
SEER
A +
50
SCOP
A +
Cooling
Heating
Cooling
Heating
25
SEER
A +++
SCOP
A +++
Cooling
Heating
✽ MXZ connection only
Inverter
Super energysaving
Super energy-saving
SEER
A
SCOP
A
Energy Rank
Ultra-quiet
Ultra-quiet operation Cooling
Heating
Cooling and heating operation
Compatible for connection to MXZ Series system ✽ To confirm compatibility with the MXZ Series multi-type system, refer to the MXZ Series page.
STEP 2 SELECT OUTDOOR UNIT
Some outdoor units in the line-up have heaters for use in cold regions. Units with an “H” in the model name are equipped with heaters.
Heater Installed
MUZ-FH25/35VEHZ
MUZ-EF25/35VEH
MUZ-SF25/35/42VEH
MUFZ-KJ25/35VEHZ
MUZ-FH50VEHZ
MUZ-SF50VEH
MUFZ-KJ50VEHZ
Selecting a Heater-equipped Model
In regions with the following conditions, there is a possibility that water resulting from condensation on the outdoor unit when operating in the heating mode will freeze and not drain from the base.
1) Cold outdoor temperatures (temperature does not rise above 0 o C all day)
2) Areas where dew forms easily (in the mountains, valleys(surrounded by mountains), near a forest, near unfrozen lakes, ponds, rivers or hot springs), or areas with snowfall
To prevent water from freezing in the base, it is recommended that a unit with a built-in heater be purchased. Please ask your dealer representative about the best model for you.
30
31
MSZ-FH25/35/50VE
MSZ-F
SERIES
The F Series is designed for optimum cooling/heating performance as well as operational comfort. Quiet, energy-saving operation is supported by some of Mitsubishi Electric’s latest technologies. Advanced functions such as “3D i-see Sensor” temperature control and the
Plasma Quad air purification system raise room comfort levels to new heights.
High Energy Efficiency
Power consumption has been reduced for the cooling and heating modes thanks to the incorporation of our newest inverter technologies. The high energy efficiency of the Size 25 units has obtained a rating of more than 5.0 for both seasonal coefficient of performance (SCOP) and seasonal energy efficiency rating (SEER).
SEER
9.1
SCOP
5.1
SEER
8.9
SCOP
5.1
SEER
7.2
SCOP
4.6
25/35
SEER
A +++
25/35
SCOP
A +++
Cooling
Heating
SEER Rank A(5.1)
SCOP Rank A(3.4)
MSZ-FH25VE MSZ-FH35VE MSZ-FH50VE
Hyper Heating
The Hyper Heating feature is incorporated, realizing powerful heating even in the harsh cold. Even users in cold regions can comfortably rely on the MSZ-FH Series for all their heating needs.
Operation Guaranteed at
Outside Temperature of -25°C
MUZ-FH VEHZ can be operated at outside temperatures as low as -25°C, so there are no concerns about use even in very cold climates.
Rated Capacity Demonstrated at
Outside Temperatures of -15°C
With rated capacity ensured at outside temperature as low as -15°C, the FH Series can be relied upon to properly warm living spaces even in severe cold snaps.
Freeze-prevention Heater
Equipped as Standard (VEHZ)
The Freeze-prevention heater prevents lowered capacity due to the drain freezing and also inhibits operation shutdowns.
Frozen drain Drain does not freeze
-25 o
C -20 o
C
MUZ-FH VEHZ
-15 o
C
MUZ-FH VE
-10 o
C
2.5
kW
3.2
kW
MUZ-FH25VE MUZ-FH25VEHZ
3.2
kW
4.0
kW
MUZ-FH35VE MUZ-FH35VEHZ
Without Freeze-prevention heater With Freeze-prevention heater
Selecting a Heater-equipped Model
In regions with the following conditions, there is a possibility that water resulting from condensation on the outdoor unit when operating in the heating mode will freeze and not drain from the base.
1) Cold outdoor temperatures (temperature does not rise above 0°C all day)
2) Areas where dew forms easily (in the mountains, valleys(surrounded by mountains), near a forest, near unfrozen lakes, ponds, rivers or hot springs), or areas with snowfall
To prevent water from freezing in the base, it is recommended that a unit with a built-in heater be purchased. Please ask your dealer representative about the best model for you.
Air, like water, is something we use everyday unconsciously. Yet, clean, fresh air is a vital part of creating a healthy space for humans.
Achieving this healthy air is Plasma Quad, a plasma-based filter system that effectively removes four kinds of air pollutants; namely, bacteria, viruses, allergens and dust, which the air contains countless particles of.
Bacteria
Test results have confirmed that Plasma Quad neutralizes 99% of bacteria in 115 minutes in a
25m 3 test space.
Plasma Quad off Plasma Quad on
Viruses
Test results have confirmed that Plasma Quad n e u t r a l i z e s 9 9 % o f v i r u s p a r t i c l e s i n 6 5 minutes in a 25m 3 test space.
Without Plasma Quad With Plasma Quad
* Hepatic cells turn transparent when affected by a virus.
Allergens
Effective deodorizing using the air-purifying filter
In a test, air containing cat fur and pollen was passed through the air cleaning device at the low airflow setting. Before and after measurements confirm that Plasma Quad neutralizes
94% of cat fur and 98% of pollen.
(Image)
Dust
In a test, air containing dust and ticks was passed through the air cleaning device at the low airflow setting. Before and after measurements confirm that Plasma Quad removes
88.6% of dust and ticks.
[ Effective Range ]
Macro
Dust
Particulate size Nano
Allergens
Pollen Bacteria
Mold spores
Viruses Bad Odours
Viruses
Pet odours Fish odours
Rubbish odours
Plasma Quad Air-purifying filter
Principle of Plasma Quad
Plasma Quad attacks bacteria and viruses from inside the unit using a strong curtain-like electrical field and discharge of electric current across the whole inlet-air opening of the unit. Tungsten discharge electrodes are used as they provide both discharge capacity and strength. In addition, through flattening the standard, round form of the field to a ribbon-like shape, a strong electrical field is produced.
Round:
Air
Dust
Virus
Bacteria
Plasma field
Flattened: a strong electrical field is produced.
Neutralization/inactivation
Air
32
33
The FH Series is equipped with 3D i-see Sensor, an infrared-ray sensor that measures the temperature at distant positions. While moving to the left and right, eight vertically arranged sensor elements analyze the room temperature in three dimensions. This detailed analysis m a k e s i t p o s s i b l e t o j u d g e w h e r e p e o p l e a r e i n t h e room, thus allowing creation of features such as “Indirect airflow,” to avoid airflow hitting people directly, and “direct airflow” to deliver airflow to where people are.
Indirect Airflow
The indirect airflow setting can be used when the flow of air feels too strong or direct. For example, it can be used during cooling to avert airflow and prevent body temperature from becoming excessively cooled.
Direct Airflow
This setting can be used to directly target airflow at people such as for immediate comfort when coming indoors on a hot
(cold) day.
Sensor with eight elements
Absence Detection
The sensors detect whether there are people in the room. When no-one is in the room, the unit automatically switches to energy-saving mode.
8 × 94 areas
Sensor measures while moving to the left to right
Divided into 94
(Image)
Natural Flow
To create “healthy” airflow, the most important aspect is that the flow of air feels natural. Mitsubishi Electric’s solution to this is Natural Flow, only possible thanks to our technology that freely and flexibly controls airflow.
Natural Flow (in Cooling)
40.0
The “3D i-see Sensor” detects people’s absence and the power consumption is automatically reduced approximately 10% after 10 minutes and 20% after 60 minutes.
24-hour Timer
Double Vane
23.0
Gentle airflow that avoids overcooling
Direct airflow (in Cooling)
40.0
Mitsubishi Electric’s double vane separates the airflow in the left and right directions to deliver airflow not only across a wide area of the room, but also simultaneously to two people in different locations.
Through realizing airflow that imitates a natural breeze, we have avoided the unpleasant feeling of being hit directly by constant, unnatural airflow.
23.0
Legs become too cold
Base data for Natural Flow
Kirigamine Highland measuring actual data of natural wind
Kirigamine Highland is one of the most famous sightseeing spots in Japan, and is visited by a large number of people for its pleasant and comfortable environment. At Mitsubishi Electric, we have attempted to recreate this Kirigamine
Highland comfort. As part of development, seeking to create a natural airflow, we measured actual data on the refreshing breezes of Kirigamine Highland. Through imitating the natural waveforms of this data, we have been able to recreate almost-imperceptible currents of gently comforting airflow.
Analysis of natural wind
Wind speed [cm/s]
140
120
100
80
60
40
20
0
0 20 40
Wind of Kirigamine
60 80 100 120
Time [s]
Natural Flow(FH SERIES)
MSZ-F
SERIES
Indoor Unit
Please fill out the requested information
Please fill out the requested information
MSZ-FH25/35/50VE
Outdoor Unit
MUZ-FH25/35VE
25 / 35
SEER
A +++
25 / 35
SCOP
A +++
Remote Controller
MUZ-FH50VE
Optional Optional
HUMAN
Optional
Wi-Fi
Interface
VERTICAL
Natural Flow
HORIZONTAL 24-hour Timer
Type
Indoor Unit
Outdoor Unit
Refrigerant
Power
Supply
Source
Outdoor ( V / Phase / Hz )
Design load
Annual electricity consumption
(*2)
SEER (*4) kW kWh/a
Cooling
Heating
(Average
Season) (*5)
Capacity
Total Input
Design load
Energy effi ciency class
Rated
Min-Max
Rated kW kW kW kW at reference design temperature kW
Declared
Capacity at bivalent temperature at operation limit temperature
Back up heating capacity
Annual electricity consumption (*2)
SCOP (*4) kW kW kW kWh/a
Energy effi ciency class
Rated
Capacity
Total Input
Operating Current (Max)
Input
Min-Max
Rated
Rated
Operating Current(Max)
Dimensions H*W*D
Indoor
Unit
Weight
Air Volume (SLo-Lo-
Mid-Hi-SHi (*3) (Dry/Wet))
Cooling
Heating kW kW kW
A kW
A mm kg m 3 /min m 3 /min
Outdoor
Unit
Sound Level (SPL)
(SLo-Lo-Mid-Hi-SHi (*3) )
Cooling
Heating
Sound Level (PWL) Cooling
Dimensions
Weight
H*W*D
Air Volume
Cooling
Heating
Cooling
Sound Level (SPL)
Heating
Sound Level (PWL) Cooling
Operating Current (Max)
Ext.
Piping
Breaker Size
Diameter
Max.Length
Max.Height
Guaranteed Operating
Range (Outdoor)
Liquid/Gas
Out-In
Out-In
Cooling
Heating dB(A) dB(A) dB(A)
A
A mm m dB(A) dB(A) dB(A) mm kg m
3
/min m 3 /min m
˚C
˚C
MSZ-FH25VE
MUZ-FH25VE
2.5
96
9.1
A+++
2.5
1.4-3.5
0.485
3.0(-10°C)
3.0(-10°C)
3.0(-10°C)
2.5(-15°C)
0.0(-10°C)
819
5.1
A+++
3.2
1.8-5.5
0.580
9.6
0.029
0.4
305(+17)-925-234
13.5
3.9-4.7-6.3-8.6-11.6
4.0-4.7-6.4-9.2-13.2
20-23-29-36-42
20-24-29-36-44
58
550-800-285
37
31.3
31.3
46
49
60
9.6
9.2
6.35/9.52
20
12
-10 ~ +46
-15 ~ +24
Inverter Heat Pump
MSZ-FH35VE
MUZ-FH35VE
R410A (*1)
Outdoor Power supply
230/Single/50
3.5
138
8.9
A+++
3.5
0.8-4.0
0.820
3.6(-10°C)
3.6(-10°C)
3.6(-10°C)
3.2(-15°C)
0.0(-10°C)
986
5.1
A+++
4.0
1.0-6.3
0.800
10.0
0.029
0.4
305(+17)-925-234
13.5
3.9-4.7-6.3-8.6-11.6
4.0-4.7-6.4-9.2-13.2
21-24-29-36-42
21-24-29-36-44
58
550-800-285
37
33.6
33.6
49
50
61
9.6
10
6.35/9.52
20
12
-10 ~ +46
-15 ~ +24
MSZ-FH50VE
MUZ-FH50VE
5.0
244
7.2
A++
5.0
1.9-6.0
1.380
4.5(-10°C)
4.5(-10°C)
4.5(-10°C)
5.2(-15°C)
0.0(-10°C)
1372
4.6
A++
6.0
1.7-8.7
1.480
14.0
0.031
0.4
305(+17)-925-234
13.5
6.4-7.4-8.6-10.1-12.4
5.7-7.2-9.0-11.2-14.6
27-31-35-39-44
25-29-34-39-46
60
880-840-330
55
48.8
51.3
51
54
64
13.6
16
6.35 / 12.7
30
15
-10 ~ +46
-15 ~ +24
(*1) Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant fl uid with a GWP equal to 1975. This means that if 1 kg of this refrigerant fl uid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher than 1 kg of CO
2
, over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
(*2) Energy consumption based on standard test results.Actual energy consumption will depend on how the appliance is used and where it is located.
(*3) SHi: Super High
(*4) SEER, SCOP and other related description are based on COMMISSION DELEGATED REGULATION (EU) No.626/2011. The temperature conditions for calculating SCOP are based on “Average Season”.
(*5) Please see page 47 for heating (warmer season) specifi cations.
34
MSZ-EF18-50VE2B
MSZ-E
SERIES
Developed to complement modern interior room décor, Kirigamine
ZEN air conditioners are available in three colours specially chosen to blend in naturally wherever installed.
35
Stylish Line-up Matches
Any Room Décor
The streamlined wall-mounted indoor units have eloquent silver-bevelled edges, expressing sophistication and quality.
Combining impressively low power consumption and quiet yet powerful performance, these units provide a bestmatch scenario for diverse interior designs while simultaneously ensuring maximum room and energy savings.
Energy-efficient Operation
25-35 25-42*
SEER
A +++
SCOP
A ++
*except for VEH
All models in the series have achieved high energy-savings rating, and are contributing to reduced energy consumption in homes, offices and a range of other settings. Offered in a variety of output capacities and installation patterns, the vast applicability promises an ideal match for any user.
2D33VA 2D40VA 2D53VA 3D54VA
Compatibility
MXZ
3D68VA 4D72VA 4D83VA 5D102VA 6C122VA
Outdoor
Indoor
MSZ-EF18VE2
MSZ-EF22VE2
MSZ-EF25VE2
MSZ-EF35VE2
MSZ-EF42VE2
MSZ-EF50VE2
*VEH
Rank A for single connection
MUZ-EF25/35VE(H)
MUZ-EF42/50VE
–
–
A + + + / A ++ (A ++ *)
A + + + / A ++ (A + *)
A + + / A ++
A + + / A +
Quiet Comfort All Day Long
Mitsubishi Electric’s advanced “Silent Mode” fan speed setting provides super-quiet operation as low as 21dB for EF18/22/25/35 models. This unique feature makes the Kirigamine ZEN series ideal for use in any situation.
Low Standby Power
Electrical devices consume standby power even when they are not in actual use. While we obviously strive to reduce power consumption during actual use, reducing this wasted power that cannot be seen is also very important.
● Noise Level
Subway car interior
Quiet passenger car interior
(40km/h)
Library interior
Sound of rustling leaves
Human hearing limits
(Extremely quiet) without
“Low standby power” around 10W
80dB 60dB 40dB 10dB
Only
21 dB
(for EF18/22/25/35 models)
Superior Exterior and Operating Design Concept
The indoor unit of the Kirigamine ZEN keeps its amazingly thin form even during operation. The only physical change notable is the movement of the variable vent. As a result, a slim attractive look is maintained.
with
“Low standby power” below
1W
90% reduction
Outdoor Units for Cold Region
(25/35)
Single split-type outdoor units are available in both standard and heater-equipped units. An electric heater is installed in each unit to prevent freezing in cold outdoor environments.
Standard Units Heater Installed
Closed Open
MUZ-EF25/35VE MUZ-EF25/35VEH
around
90% reduction
MSZ-E
Indoor Unit
Please fill out the requested information
Please fill out the requested information
MSZ-EF18/22/25/35/42/50VE2W White
Outdoor Unit
MUZ-EF25/35VE(H),42VE
25 - 35 25 - 42*
SEER
A +++
SCOP
A ++
*except for VEH
Remote Controller
MSZ-EF18/22/25/35/42/50VE2S Silver
MSZ-EF18/22/25/35/42/50VE2B*
*Soft-dry Cloth is enclosed with Black models.
Electrostatic
Anti-allergy
Black MUZ-EF50VE
Optional Optional Optional
Wi-Fi
Interface
Type
Indoor Unit
Outdoor Unit
Refrigerant
Power
Supply
Cooling
Heating
(Average
Season)
Ext.
Piping
(*5)
Source
Outdoor ( V / Phase / Hz )
Design load
Annual electricity consumption
SEER (*4)
Sound Level (SPL)
(SLo-Lo-Mid-Hi-SHi
Breaker Size
Diameter
Max.Length
Max.Height
Guaranteed Operating
Range (Outdoor)
(*3) )
Cooling
Heating
Sound Level (PWL) Cooling
Dimensions
Weight
H*W*D
Air Volume
Cooling
Heating
Cooling
Sound Level (SPL)
Heating
Sound Level (PWL) Cooling
Operating Current (Max)
(*2) kW kWh/a
Capacity
Total Input
Design load
Energy effi ciency class
Rated
Min-Max
Rated kW kW kW kW at reference design temperature kW
Declared
Capacity at bivalent temperature at operation limit temperature
Back up heating capacity
Annual electricity consumption (*2)
SCOP (*4) kW kW kW kWh/a
MSZ-EF18VE2
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Energy effi ciency class
Rated
Capacity
Total Input
Operating Current (Max)
Input
Min-Max
Rated
Rated
Operating Current(Max)
Dimensions H*W*D
Indoor
Unit
Weight
Air Volume (SLo-Lo-
Mid-Hi-SHi (*3) (Dry/Wet))
Cooling
Heating kW kW kW
A kW
-
-
-
-
-
0.027
A mm
0.3
299-895-195 kg 11.5
m 3 /min 4.0 - 4.6 - 6.3 - 8.3 - 10.5
m 3 /min 4.0 - 4.6 - 6.2 - 8.9 - 11.9
Outdoor
Unit
Liquid/Gas
Out-In
Out-In
Cooling
Heating dB(A) dB(A) dB(A) mm kg m
3
/min m 3 /min dB(A) dB(A) dB(A)
A
A mm m m
˚C
˚C
21 - 23 - 29 - 36 - 42
21 - 24 - 29 - 37 - 45
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
MSZ-EF22VE2 for MXZ connection
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
0.027
0.3
299-895-195
11.5
4.0 - 4.6 - 6.3 - 8.3 - 10.5
4.0 - 4.6 - 6.2 - 8.9 - 11.9
21 - 23 - 29 - 36 - 42
21 - 24 - 29 - 37 - 45
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
MSZ-EF25VE2
MUZ-EF25VE
2.5
103
8.5
A+++
2.5
1.2-3.4
0.545
2.4(-10ºC)
2.4(-10ºC)
2.4(-10ºC)
2.0(-15ºC)
0.0(-10ºC)
716
4.7
A++
3.2
1.1-4.2
0.700
7.3
0.027
0.3
299-895-195
11.5
4.0 - 4.6 - 6.3 - 8.3 - 10.5
4.0 - 4.6 - 6.2 - 8.9 - 11.9
21 - 23 - 29 - 36 - 42
21 - 24 - 29 - 37 - 45
60
550-800-285
30
32.6
32.2
47
48
58
7.0
10
6.35 / 9.52
20
12
-10 ~ +46
-15 ~ +24
Inverter Heat Pump
MSZ-EF25VE2
MUZ-EF25VEH
MSZ-EF35VE2
MUZ-EF35VE
R410A (*1)
Outdoor Power supply
230/Single/50
2.5
3.5
103
8.5
A+++
2.5
1.2-3.4
0.545
2.4(-10ºC)
2.4(-10ºC)
2.4(-10ºC)
1.6(-20ºC)
0.0(-10ºC)
730
4.6
A++
3.2
1.1-4.2
0.700
7.3
0.027
0.3
299-895-195
11.5
4.0 - 4.6 - 6.3 - 8.3 - 10.5
4.0 - 4.6 - 6.2 - 8.9 - 11.9
21 - 23 - 29 - 36 - 42
21 - 24 - 29 - 37 - 45
60
550-800-285
30
32.6
32.2
47
48
58
7.0
10
6.35 / 9.52
20
12
-10 ~ +46
-20 ~ +24
144
8.5
A+++
3.5
1.4-4.0
0.910
2.9(-10ºC)
2.9(-10ºC)
2.9(-10ºC)
2.4(-15ºC)
0.0(-10ºC)
882
4.6
A++
4.0
1.8-5.5
0.955
8.5
0.031
0.3
299-895-195
11.5
4.0 - 4.6 - 6.3 - 8.3 - 10.5
4.0 - 4.6 - 6.2 - 8.9 - 12.7
21 - 24 - 29 - 36 - 42
21 - 24 - 30 - 38 - 46
60
550-800-285
35
33.6
33.6
49
50
61
8.2
10
6.35 / 9.52
20
12
-10 ~ +46
-15 ~ +24
MSZ-EF35VE2
MUZ-EF35VEH
3.5
144
8.5
A+++
3.5
1.4-4.0
0.910
2.9(-10ºC)
2.9(-10ºC)
2.9(-10ºC)
1.7(-20ºC)
0.0(-10ºC)
910
4.5
A+
4.0
1.8-5.5
0.955
8.5
0.031
0.3
299-895-195
11.5
4.0 - 4.6 - 6.3 - 8.3 - 10.5
4.0 - 4.6 - 6.2 - 8.9 - 12.7
21 - 24 - 29 - 36 - 42
21 - 24 - 30 - 38 - 46
60
550-800-285
35
33.6
33.6
49
50
61
8.2
10
6.35 / 9.52
20
12
-10 ~ +46
-20 ~ +24
MSZ-EF42VE2
MUZ-EF42VE
A++
5.4
1.4-6.3
1.460
9.5
0.031
0.3
299-895-195
11.5
5.8 - 6.6 - 7.7 - 8.9 - 10.3
5.5 - 6.3 - 7.8 - 9.9 - 12.7
28 - 31 - 35 - 39 - 42
28 - 30 - 35 - 41 - 48
60
4.2
192
7.7
A++
4.2
0.9-4.6
1.280
3.8(-10ºC)
3.8(-10ºC)
3.8(-10ºC)
3.4(-15ºC)
0.0(-10ºC)
1155
4.6
550-800-285
35
35.2
33.6
50
51
62
9.2
10
6.35 / 9.52
20
12
-10 ~ +46
-15 ~ +24
MSZ-EF50VE2
MUZ-EF50VE
5.0
244
7.2
A++
5.0
1.4-5.4
1.560
4.2(-10ºC)
4.2(-10ºC)
4.2(-10ºC)
3.5(-15ºC)
0.0(-10ºC)
1309
4.5
A+
5.8
1.6-7.5
1.565
12.4
0.034
0.4
299-895-195
11.5
5.8 - 6.8 - 7.9 - 9.3 - 11.0
6.4 - 7.3 - 9.0 - 11.1 - 13.2
30 - 33 - 36 - 40 - 43
30 - 33 - 37 - 43 - 49
60
880-840-330
54
44.6
44.6
52
52
65
12.0
16
6.35 / 12.7
30
15
-10 ~ +46
-15 ~ +24
(*1) Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant fl uid with a GWP equal to 1975. This means that if 1 kg of this refrigerant fl uid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher than 1 kg of CO
2
, over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
(*2) Energy consumption based on standard test results.Actual energy consumption will depend on how the appliance is used and where it is located.
(*3) SHi: Super High
(*4) SEER, SCOP and other related description are based on COMMISSION DELEGATED REGULATION (EU) No.626/2011. The temperature conditions for calculating SCOP are based on “Average Season”.
(*5) Please see page 47 for heating (warmer season) specifi cations.
36
37
MSZ-SF15/20VA
MSZ-S
SERIES
MSZ-G
SERIES
MSZ-SF25/35/42/50VE
MSZ-GF60/71VE
Introducing a compact and stylish indoor unit with amazingly quiet performance.
Not only are neat installations in small bedrooms possible, increase energy-savings by selecting the optimal capacity required for each room.
“Rank A
++
/A
+
” Energy Savings Achieved for Entire Range of Series
25-71
SEER
A ++
25-71
SCOP
A +
All models in the series, from the low-capacity 25 to the high-capacity 71, have achieved the “Rank A ++ ” for SEER and “Rank A + ” for SCOP as energy-savings rating. For home use, such as in bedrooms and living rooms, to light commercial use, such as in offices, our air conditioners are contributing to reduced energy consumption in a wide range.
Cooling Heating
SEER
7.6
SEER
7.2
SEER
7.5
SEER
7.2
SEER
6.8
SEER
6.8
SCOP
4.4
SCOP
4.4
SCOP
4.4
SCOP
4.4
SCOP
4.3
SCOP
4.2
SEER Rank A(5.1)
SCOP Rank A(3.4)
MSZ-SF25VE MSZ-SF35VE MSZ-SF42VE MSZ-SF50VE MSZ-GF60VE MSZ-GF71VE
Wide Line-up
Eight different indoor units (Model 15-71) are available to meet your diversified air conditioning needs.
MSZ-SF15 / 20VA*
*for MXZ connection
MSZ-SF25 / 35 / 42 / 50VE
Compact and Stylish
(MSZ-SF15/20VA)
The stylish, square indoor unit adds a touch of class to any room interior. The compact design is 64mm thinner than our previous indoor unit with the lowest output capacity (MSZ-GE22VA).
Comparison with our previous model GE
45mm less
64mm less 38mm less
MSZ-GF60 / 71VE
Family Design
(MSZ-SF15/20/25/35/42/50)
Models in the 25-50 class are introduced as single-split units while retaining the popular design of the SF15/20VA* as indoor units exclusively for multi-systems. From small rooms to living rooms, it is possible to coordinate residences with a unified design.
*Size may vary.
around
90% reduction
“Weekly Timer”
Easily set desired temperatures and operation start/stop times to match lifestyle patterns. Reduce wasted energy consumption by using the timer to prevent forgetting to turn off the unit and eliminate temperature setting adjustments.
■ Example Operation Pattern (Winter/Heating mode)
Mon.
ON 20°C
Tues.
ON 20°C
Wed.
Thurs.
Fri.
ON 20°C ON 20°C ON 20°C
Automatically changes to high-power operation at wake-up time
Sat.
ON 20°C
Sun.
ON 20°C
OFF OFF OFF OFF
Automatically turned off during work hours
OFF ON 18°C ON 18°C
Midday is warmer, so the temperature is set lower
(during sleeping hours)
ON 20°C
ON 18°C
ON 20°C ON 20°C ON 20°C
Automatically turns on, synchronized with arrival at home
ON 18°C ON 18°C ON 18°C
ON 20°C
ON 18°C
ON 20°C ON 20°C
Automatically raises temperature setting to match time when outside-air temperature is low
ON 18°C
Automatically lowers temperature at bedtime for energy-saving operation at night
ON 18°C
Settings
Pattern Settings: Input up to four settings for each day
Settings: • Start/Stop operation • Temperature setting ✽The operation mode cannot be set.
■ Easy set-up using dedicated buttons
PUSH
The remote controller is equipped with buttons that are used exclusively for setting the Weekly Timer.
Setting operation patterns is easy and quick.
How to set the Weekly
Timer
PUSH
Ready to set
PUSH
PUSH
Select the day
PUSH
PUSH
Select the period
PUSH
Complete
Select ON/OFF Select the time Set the temperature
•
Start by pushing the “SET” button and follow the instructions to set the desired patterns.
Once all of the desired patterns are input, point the top end of the remote controller at the indoor unit and push the “SET” button one more time. (Push the “SET” button only after inputting all of the desired patterns into the remote controller memory. Pushing the “CANCEL” button will end the set-up process without sending the operation patterns to the indoor unit).
•
It takes a few seconds to transmit the Weekly Timer operation patterns to the indoor unit.
Please continue to point the remote controller at the indoor unit until all data has been sent.
•
When “Weekly Timer” is set, temperature can not be set 10°C.
Low Standby Power
Electrical devices consume standby power even when they are not in actual use.
While we obviously strive to reduce power consumption during actual use, reducing this wasted power that cannot be seen is also very important.
without
“Low standby power” with
“Low standby power” below
1W around 10W
90% reduction
Nano Platinum Filter
(MSZ-SF25/35/42/50,MSZ-GF60/71)
This filter incorporates nanometre-sized platinum-ceramic particles that generate stable antibacterial and deodourising effects. The size of the three-dimensional surface has been increased as well, enlarging the filter capture area. These features give the Nano Platinum
Filter better dust collection performance than conventional filters.
The superior air-cleaning effectiveness raises room comfort yet another level.
“i save” Mode
“i save” is a simplified setting function that recalls the preferred
(preset) temperature by pressing a single button on the remote controller. Press the same button twice in repetition to immediately return to the previous temperature setting. Using this function contributes to comfortable, waste-free operation, realising the most suitable air conditioning settings and saving on power consumption when, for example, leaving the room or going to bed.
Heating Heating
22°C 18°C
✽ It is okay to wash the filter with water
(air-cleaning effect is maintained)
3D surface (Waved surface)
Outdoor Units for Cold Region
(25/35/42/50)
Single split-type outdoor units are available in both standard and heater-equipped units. An electric heater is installed in each unit to prevent freezing in cold outdoor environments.
✽ Temperature can be preset to 10°C when heating in the “i-save” mode
(except when connected to MXZ-8B140VA/YA, MXZ-8B160VA/YA).
Standard Units Heater Installed
MUZ-SF25/35/42VE MUZ-SF50VE MUZ-SF25/35/42VEH MUZ-SF50VEH
38
MSZ-S
SERIES
Indoor Unit
MSZ-SF15/20VA
Outdoor Unit
For MXZ Connection Only
Remote Controller
Optional Optional Optional
Wi-Fi
Interface
39
Type
Indoor Unit
Outdoor Unit
Refrigerant
Power
Supply
Cooling
Heating
(Average
Season) (*5)
Source
Outdoor ( V / Phase / Hz )
Design load
Annual electricity consumption
SEER (*4)
(*2) kW kWh/a
Capacity
Total Input
Design load
Energy effi ciency class
Rated
Min-Max
Rated kW kW kW kW at reference design temperature kW
Declared
Capacity at bivalent temperature at operation limit temperature
Back up heating capacity
Annual electricity consumption (*2)
SCOP (*4) kW kW kW kWh/a
MSZ-SF15VA
-
-
-
-
-
-
-
-
-
-
-
-
-
-
MSZ-SF20VA for MXZ connection
-
-
-
-
-
-
-
-
-
-
-
-
-
-
764
4.4
Inverter Heat Pump
MSZ-SF25VE
MUZ-SF25VE
2.5
116
7.6
A++
2.5
R410A (*1)
MSZ-SF25VE
MUZ-SF25VEH
Outdoor Power supply
0.9-3.4
0.600
2.4(-10ºC)
2.4(-10ºC)
2.4(-10ºC)
2.0(-15ºC)
0.0(-10ºC)
230/Single/50
2.5
116
7.6
A++
2.5
0.9-3.4
0.600
2.4(-10ºC)
2.4(-10ºC)
2.4(-10ºC)
1.6(-20ºC)
0.0(-10ºC)
790
4.3
MSZ-SF35VE
MUZ-SF35VE
3.5
171
7.2
A++
3.5
1.1-3.8
1.080
2.9(-10ºC)
2.9(-10ºC)
2.9(-10ºC)
2.2(-15ºC)
0.0(-10ºC)
923
4.4
Energy effi ciency class
Rated
Capacity
Total Input
Operating Current (Max)
Input
Min-Max
Rated
Rated
Operating Current(Max)
Dimensions H*W*D
Indoor
Unit
Weight
Air Volume (SLo-Lo-
Mid-Hi-SHi (*3) (Dry/Wet))
Cooling
Heating kW kW kW
A kW
-
-
-
-
-
0.017
-
-
-
-
-
0.019
A+
3.2
1.0-4.1
0.780
8.4
0.024
A+
3.2
1.0-4.1
0.780
8.4
0.024
A+
4.0
1.3-4.6
1.030
8.5
0.027
A mm
0.17
250-760-168
0.19
250-760-168
0.2
299-798-195
0.2
299-798-195
0.3
299-798-195 kg 7.7
7.7
10 m 3 /min 3.5 - 3.9 - 4.6 - 5.5 - 6.4
3.5 - 3.9 - 4.6 - 5.5 - 6.9
3.5 - 4.1 - 5.6 - 7.2 - 9.1
10
3.5 - 4.1 - 5.6 - 7.2 - 9.1
10
3.5 - 4.1 - 5.6 - 7.2 - 9.1
m 3 /min 3.7 - 4.4 - 5.0 - 6.0 - 6.8
3.7 - 4.4 - 5.0 - 6.0 - 7.3
3.5 - 4.1 - 6.7 - 8.2 - 10.3
3.5 - 4.1 - 6.7 - 8.2 - 10.3
3.5 - 4.1 - 6.7 - 8.3 - 11.0
Outdoor
Unit
Sound Level (SPL)
(SLo-Lo-Mid-Hi-SHi (*3) )
Cooling
Heating
Sound Level (PWL) Cooling
Dimensions
Weight
H*W*D
Air Volume
Cooling
Heating
Cooling
Sound Level (SPL)
Heating
Sound Level (PWL) Cooling
Operating Current (Max)
Ext.
Piping
Breaker Size
Diameter
Max.Length
Max.Height
Guaranteed Operating
Range (Outdoor)
Liquid/Gas
Out-In
Out-In
Cooling
Heating dB(A) dB(A) dB(A) mm kg m
3
/min m 3 /min dB(A) dB(A) dB(A)
A
A mm m m
˚C
˚C
21 - 26 - 30 - 35 - 40
21 - 26 - 30 - 35 - 40
-
-
-
-
-
-
-
-
-
-
6.35/9.52
-
-
-
-
21 - 26 - 30 - 35 - 42
21 - 26 - 30 - 35 - 42
-
-
-
-
-
-
-
-
-
-
6.35/9.52
-
-
-
-
21 - 24 - 30 - 36 - 42
21 - 24 - 34 - 39 - 45
57
550-800-285
31
31.1
30.7
47
48
58
8.2
10
6.35 / 9.52
20
12
-10 ~ +46
-15 ~ +24
21 - 24 - 30 - 36 - 42
21 - 24 - 34 - 39 - 45
57
550-800-285
31
31.1
30.7
47
48
58
8.2
10
6.35 / 9.52
20
12
-10 ~ +46
-20 ~ +24
21 - 24 - 30 - 36 - 42
21 - 24 - 34 - 40 - 46
57
550-800-285
31
35.9
35.9
49
50
62
8.2
10
6.35 / 9.52
20
12
-10 ~ +46
-15 ~ +24
MSZ-SF35VE
MUZ-SF35VEH
(*1) Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant fl uid with a GWP equal to 1975. This means that if 1 kg of this refrigerant fl uid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher than 1 kg of CO
2
, over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
(*2) Energy consumption based on standard test results.Actual energy consumption will depend on how the appliance is used and where it is located.
(*3) SHi: Super High
(*4) SEER, SCOP and other related description are based on COMMISSION DELEGATED REGULATION (EU) No.626/2011. The temperature conditions for calculating SCOP are based on “Average Season”.
(*5) Please see page 47 for heating (warmer season) specifi cations.
3.5
171
7.2
A++
3.5
1.1-3.8
1.080
2.9(-10ºC)
2.9(-10ºC)
2.9(-10ºC)
1.6(-20ºC)
0.0(-10ºC)
948
4.3
A+
4.0
1.3-4.6
1.030
8.5
0.027
0.3
299-798-195
10
3.5 - 4.1 - 5.6 - 7.2 - 9.1
3.5 - 4.1 - 6.7 - 8.3 - 11.0
21 - 24 - 30 - 36 - 42
21 - 24 - 34 - 40 - 46
57
550-800-285
31
35.9
35.9
49
50
62
8.2
10
6.35 / 9.52
20
12
-10 ~ +46
-20 ~ +24
MSZ-S
SERIES
MSZ-G
SERIES
Indoor Unit
Please fill out the requested information
Please fill out the requested information
Outdoor Unit
SEER
A ++
SCOP
A +
Remote Controller
MSZ-SF25/35/42/50VE
MUZ-SF25/35/42VE(H)
MSZ-GF60/71VE
Optional Optional Optional
Optional
Wi-Fi
Interface
Electrostatic
Anti-allergy
Optional
Nano
Platinum
MUZ-SF50VE(H)
MUZ-GF60/71VE
Type
Indoor Unit
Outdoor Unit
Refrigerant
Power
Supply
Cooling
Heating
(Average
Season) (*5)
Source
Outdoor ( V / Phase / Hz )
Design load
Annual electricity consumption
SEER (*4)
(*2) kW kWh/a
Capacity
Total Input
Design load
Energy effi ciency class
Rated
Min-Max
Rated kW kW kW kW at reference design temperature kW
Declared
Capacity at bivalent temperature at operation limit temperature
Back up heating capacity
Annual electricity consumption (*2)
SCOP (*4) kW kW kW kWh/a
MSZ-SF42VE
MUZ-SF42VE
4.2
196
7.5
A++
4.2
0.8-4.5
1.340
3.8(-10ºC)
3.8(-10ºC)
3.8(-10ºC)
3.4(-15ºC)
0.0(-10ºC)
1215
4.4
MSZ-SF42VE
MUZ-SF42VEH
4.2
196
7.5
A++
4.2
0.8-4.5
1.340
3.8(-10ºC)
3.8(-10ºC)
3.8(-10ºC)
2.2(-20ºC)
0.0(-10ºC)
1242
4.3
Energy effi ciency class
Rated
Capacity
Total Input
Operating Current (Max)
Input
Min-Max
Rated
Rated
Operating Current(Max)
Dimensions H*W*D
Indoor
Unit
Weight
Air Volume (SLo-Lo-
Mid-Hi-SHi (*3) (Dry/Wet))
Cooling
Heating kW kW kW
A kW
A+
5.4
1.3-6.0
1.580
9.5
0.027
A+
5.4
1.3-6.0
1.58
9.5
0.027
A mm
0.3
299-798-195
0.3
299-798-195 kg 10 m 3 /min 5.0 - 5.8 - 6.7 - 7.9 - 9.1
10
5.0 - 5.8 - 6.7 - 7.9 - 9.1
m 3 /min 5.0 - 5.8 - 7.2 - 9.1 - 11.4
5.0 - 5.8 - 7.2 - 9.1 - 11.4
Outdoor
Unit
Sound Level (SPL)
(SLo-Lo-Mid-Hi-SHi (*3) )
Cooling
Heating
Sound Level (PWL) Cooling
Dimensions
Weight
H*W*D
Air Volume
Cooling
Heating
Cooling
Sound Level (SPL)
Heating
Sound Level (PWL) Cooling
Operating Current (Max)
Ext.
Piping
Breaker Size
Diameter
Max.Length
Max.Height
Guaranteed Operating
Range (Outdoor)
Liquid/Gas
Out-In
Out-In
Cooling
Heating dB(A) dB(A) dB(A) mm kg m
3
/min m 3 /min dB(A) dB(A) dB(A)
A
A mm m m
˚C
˚C
28 - 31 - 34 - 38 - 42
28 - 31 - 36 - 42 - 47
57
550-800-285
35
35.2
33.6
50
51
63
9.2
10
6.35 / 9.52
20
12
-10 ~ +46
-15 ~ +24
28 - 31 - 34 - 38 - 42
28 - 31 - 36 - 42 - 47
57
550-800-285
35
35.2
33.6
50
51
63
9.2
10
6.35 / 9.52
20
12
-10 ~ +46
-20 ~ +24
Inverter Heat Pump
MSZ-SF50VE
MUZ-SF50VE
MSZ-SF50VE
MUZ-SF50VEH
R410A (*1)
Outdoor Power supply
230/Single/50
5
246
7.2
A++
5
1.4-5.4
1.660
4.2(-10ºC)
4.2(-10ºC)
4.2(-10ºC)
3.4(-15ºC)
0.0(-10ºC)
1351
4.4
A+
5.8
1.4-7.3
1.7
12.3
0.035
0.3
299-798-195
10
5.6 - 6.2 - 7.0 - 8.2 - 9.9
0.3
299-798-195
10
5.6 - 6.2 - 7.0 - 8.2 - 9.9
5.6 - 6.4 - 8.0 - 9.8 - 12.0
5.6 - 6.4 - 8.0 - 9.8 - 12.0
30 - 33 - 36 - 40 - 45
30 - 33 - 38 - 43 - 49
58
880-840-330
55
44.6
44.6
52
52
65
12
16
6.35 / 12.7
30
15
-10 ~ +46
-15 ~ +24
5
246
7.2
A++
5
1.4-5.4
1.660
4.2(-10ºC)
4.2(-10ºC)
4.2(-10ºC)
2.3(-20ºC)
0.0(-10ºC)
1380
4.3
A+
5.8
1.4-7.3
1.7
12.3
0.035
30 - 33 - 36 - 40 - 45
30 - 33 - 38 - 43 - 49
58
880-840-330
55
44.6
44.6
52
52
65
12
16
6.35 / 12.7
30
15
-10 ~ +46
-20 ~ +24
MSZ-GF60VE
MUZ-GF60VE
6.1
311
6.8
A++
6.1
1.4-7.5
1.790
4.6(-10ºC)
4.6(-10ºC)
4.6(-10ºC)
3.7(-15ºC)
0.0(-10ºC)
1489
4.3
A+
6.8
2.0-9.3
1.81
14.5
0.062
0.5
325-1100-238
16
9.8-11.3-13.4-15.6-18.3
9.8-11.3-13.4-15.6-18.3
29 - 37 -41 - 45 - 49
29 - 37 - 41 - 45 - 49
65
880-840-330
50
49.2
49.2
55
55
65
14
20
6.35/15.88
30
15
-10 ~ +46
-15 ~ +24
MSZ-GF71VE
MUZ-GF71VE
7.1
364
6.8
A++
7.1
2.0-8.7
2.130
6.7(-10ºC)
6.7(-10ºC)
6.7(-10ºC)
5.4(-15ºC)
0.0(-10ºC)
2204
4.2
A+
8.1
2.2-9.9
2.23
16.6
0.058
0.5
325-1100-238
16
9.7-11.5-13.3-15.4-17.8
10.2-11.5-13.3-15.4-17.8
30 - 37 - 41 - 45 - 49
30 - 37 - 41 - 45 - 49
65
880-840-330
53
50.1
48.2
55
55
65
16.1
20
9.52/15.88
30
15
-10 ~ +46
-15 ~ +24
(*1) Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant fl uid with a GWP equal to 1975. This means that if 1 kg of this refrigerant fl uid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher than 1 kg of CO
2
, over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
(*2) Energy consumption based on standard test results.Actual energy consumption will depend on how the appliance is used and where it is located.
(*3) SHi: Super High
(*4) SEER, SCOP and other related description are based on COMMISSION DELEGATED REGULATION (EU) No.626/2011. The temperature conditions for calculating SCOP are based on “Average Season”.
(*5) Please see page 47 for heating (warmer season) specifi cations.
40
MSZ-HJ25 / 35 /50VA
MSZ-H
SERIES
Compact, high-performance indoor and outdoor units and advanced inverter technologies provide superior energy savings and comfort in all rooms.
41
Stylish Design with Flat Panel Front
A stylish flat panel design is employed for the front of the indoor unit. The simple look matches room aesthetics.
Advanced Inverter Control –
Efficient Operation All the Time
25·35
SEER
A
25·35
SCOP
A
50
SEER
A +
50
SCOP
A +
Mitsubishi Electric’s cutting-edge inverter technologies are adopted to provide automatic adjustment of operation load according to need. This reduces excessive consumption of electricity, and thereby realises an Energy Rank “A” rating for 25·35 classes and “A + ” for 50 classes.
Silent Operation
Quiet, relaxing space is within reach. Operational noise is a low 22dB
(25-35 classes). Operation is so silent you might even forget the air conditioner is on.
●
Noise Level
Subway car interior
Quiet passenger car interior
(40km/h)
Library interior
Sound of rustling leaves
Human hearing limits
(Extremely quiet)
80dB 60dB 40dB 10dB
Only
22dB *
*MSZ-HJ25/35VA
Long Piping Length Operating Range
Compared to previous models, the piping length is significantly increased, further enhancing the ease and flexibility of installation.
Max piping length
Max piping height
MSZ-HJ
20m
12m
MSZ-HC
10m
5m
As a result of an extended operating range when cooling, these models accommodate a wider range of usage environments and applications than previous models.
●
Operating Range (Cooling)
MUZ-HC +18°C
MUZ-HJ +15°C
+43°C
+46°C
Compact Units
The widths of both indoor and outdoor units are compact, making installation in small, tight spaces possible.
Indoor Unit: MSZ-HJ25/35/50VA Outdoor Unit: MUZ-HJ25/35VA
Only 799mm wide
Only 699mm wide
MSZ-H
SERIES
Indoor Unit
Please fill out the requested information
Please fill out the requested information
MSZ-HJ25/35/50VA
Outdoor Unit
50 50
SEER
A +
50
SCOP
A +
Remote Controller
MUZ-HJ25/35VA
MUZ-HJ50VA
Type
Indoor Unit
Outdoor Unit
Refrigerant
Power
Supply
Source
Outdoor ( V / Phase / Hz )
Design load
Annual electricity consumption
(*2)
SEER (*4) kW kWh/a
Cooling
Heating
(Average
Season) (*5)
Capacity
Total Input
Design load
Energy effi ciency class
Rated
Min-Max
Rated kW kW kW kW at reference design temperature kW
Declared
Capacity at bivalent temperature at operation limit temperature
Back up heating capacity
Annual electricity consumption (*2)
SCOP (*4) kW kW kW kWh/a
Energy effi ciency class
Rated
Capacity
Total Input
Operating Current (Max)
Input
Min-Max
Rated
Rated
Operating Current(Max)
Dimensions H*W*D
Indoor
Unit
Weight
Air Volume (SLo-Lo-
Mid-Hi-SHi (*3) (Dry/Wet))
Cooling
Heating kW kW kW
A kW
A mm kg m 3 /min m 3 /min
Outdoor
Unit
Sound Level (SPL)
(SLo-Lo-Mid-Hi-SHi (*3) )
Cooling
Heating
Sound Level (PWL) Cooling
Dimensions
Weight
H*W*D
Air Volume
Cooling
Heating
Cooling
Sound Level (SPL)
Heating
Sound Level (PWL) Cooling
Operating Current (Max)
Ext.
Piping
Breaker Size
Diameter
Max.Length
Max.Height
Guaranteed Operating
Range (Outdoor)
Liquid/Gas
Out-In
Out-In
Cooling
Heating dB(A) dB(A) dB(A)
A
A mm m dB(A) dB(A) dB(A) mm kg m
3
/min m 3 /min m
˚C
˚C
MSZ-HJ25VA
MUZ-HJ25VA
2.5
171
5.1
A
2.5
1.3 - 3.0
0.730
1.9(-10ºC)
1.9(-10ºC)
1.9(-10ºC)
1.9(-10ºC)
0.0(-10ºC)
698
3.8
A
3.15
0.9 - 3.5
0.870
5.8
0.020
0.3
290-799-232
9
3.8 - 5.5 - 7.3 - 9.5
3.5 - 5.5 - 7.5 - 10.0
22 - 30 - 37 - 43
23 - 30 - 37 - 43
57
538-699-249
24
31.5
31.5
50
50
63
5.5
10
6.35/9.52
20
12
+15 ~ +46
-10 ~ +24
Inverter Heat Pump
MSZ-HJ35VA
MUZ-HJ35VA
R410A (*1)
Indoor Power supply
230V/Single/50Hz
3.1
212
5.1
A
3.15
1.4 - 3.5
1.040
2.4(-10ºC)
2.4(-10ºC)
2.4(-10ºC)
2.4(-10ºC)
0.0(-10ºC)
885
3.8
A
3.6
1.1 - 4.1
0.995
6.5
0.021
0.3
290-799-232
9
3.8 - 5.7 - 7.8 - 10.9
3.5 - 5.5 - 7.5 - 10.3
22 - 31 - 38 - 45
23 - 30 - 37 - 44
60
538-699-249
25
31.5
31.5
50
50
64
6.2
10
6.35/9.52
20
12
+15 ~ +46
-10 ~ +24
MSZ-HJ50VA
MUZ-HJ50VA
5.0
292
6.0
A+
5.0
1.3 - 5.0
2.050
3.8(-10ºC)
3.8(-10ºC)
3.8(-10ºC)
3.8(-10ºC)
0.0(-10ºC)
1267
4.2
A+
5.4
1.4 - 6.5
1.480
9.8
0.037
0.4
290-799-232
9
6.3 - 9.1 - 11.1 - 12.9
6.1 - 8.3 - 11.1 - 14.3
28 - 36 - 40 - 45
27 - 34 - 41 - 47
60
550-800-285
36
36.3
34.8
50
51
64
9.4
12
6.35/12.7
20
12
+15 ~ +46
-10 ~ +24
(*1) Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant fl uid with a GWP equal to 1975. This means that if 1 kg of this refrigerant fl uid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher than 1 kg of CO
2
, over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
(*2) Energy consumption based on standard test results.Actual energy consumption will depend on how the appliance is used and where it is located.
(*3) SHi: Super High
(*4) SEER, SCOP and other related description are based on COMMISSION DELEGATED REGULATION (EU) No.626/2011. The temperature conditions for calculating SCOP are based on “Average Season”.
(*5) Please see page 47 for heating (warmer season) specifi cations.
42
43
MFZ
SERIES
High Capacity, Energy Savings and a Design in Harmony with Living Spaces
Raise the Value of Your Room to the Next Level.
MFZ-KJ25/35/50VE
Simple , Flat Design
Uneven surfaces have been smoothed to provide a simple design with linear beauty, harmonised with all types of interiors.
Images of installed unit
Unique configuration realising a flat, stylish look
Two-block structure to accommodate various installation patterns
Standard
Simple, symmetrical design
750
mm
Ingenious structure realizing low-profile air inlet
Removable base section
215 mm
Semi-inbuilt
Base can be removed to accentuate the stylish main body
Multi-flow Vane
Three uniquely shaped vanes control the airflow and allow the freedom to customize comfort according to preferences.
When heating When cooling
Air currents can be controlled freely
Rapid heating
Warm air is blown out in a downward direction and then sucked back into the unit to quickly raise the temperat u r e o f t h e a i r being blown out.
* The downward airflow is also possible as well as heating.
Excellent Energy-saving Performance
25
SEER
A +++
SCOP
A +
SEER A +++ (25) and SCOP A + (25/35/50) ratings have been achieved through development focusing on compliance with European energy-related product (ErP) regulations.
Cooling Heating
SEER
8.5
SEER
8.1
SCOP
4.5
SCOP
4.4
SEER
6.5
SCOP
4.3
SEER Rank A(5.1)
SCOP Rank A(3.4)
MFZ-KJ25VE MFZ-KJ35VE MFZ-KJ50VE
Weekly Timer
(Introduced in response to market demand)
Temperature settings and On/Off control can be managed over a period of one week using the Weekly Timer. Up to eight setting patterns per calendar day are possible.
Trouble-free Installation and Maintenance
Using the original installation plate that comes as standard equipment, installation of the unit is a snap. Levelling adjusters are provided, preventing damage to the wall. Generous pipe length (20–30 metres) is provided, so there is no need to worry about distance to the outdoor unit. All units are equipped with an automatic self-diagnostics function as well. Simply access the trouble log recall mode for instant troubleshooting.
MFZ-KJ
SERIES
Indoor Unit
Please fill out the requested information
Please fill out the requested information
Outdoor Unit
25
SEER
A +++
SCOP
A +
Remote Controller
MUFZ-KJ25/35VE
MFZ-KJ25/35/50VE
MUFZ-KJ50VE
Nano
Platinum
Optional
Optional
Optional
Type
Indoor Unit
Outdoor Unit
Refrigerant
Power
Supply
Source
Outdoor(V/Phase/Hz)
Cooling
Design load
Annual electricity consumption (*2)
SEER (*4)
Capacity
Energy efficiency class
Rated
Min-Max
Rated Total Input
Design load
Declared Capacity at reference design temperature at bivalent temperature at operation limit temperature kW kWh/a kW kW kW kW kW kW kW kW kWh/a
Heating
(Average
Season)
Back up heating capacity
Annual electricity consumption (*2)
SCOP (*4)
Capacity
Energy efficiency class
Rated
Total Input
Operating Current (Max)
Min-Max
Rated
Rated
Indoor
Unit
Outdoor
Unit
Input
Operating Current(Max)
Dimensions
Weight
Air Volume
(SLo-Lo-Mid-Hi-SHi (*3) )
Sound Level (SPL)
(SLo-Lo-Mid-Hi-SHi (*3) )
Sound Level (PWL)
Dimensions
Weight
Air Volume
Sound Level (SPL)
H*W*D
Cooling
Heating
Cooling
Heating
Cooling
H*W*D
Cooling
Heating
Cooling
Heating
Cooling
Ext.
Piping
Sound Level (PWL)
Operating Current(Max)
Breaker Size
Diameter
Max.Length
Max.Height
Guaranteed Operating Range
[Outdoor]
Liquid/Gas
Out-In
Out-In
Cooling
Heating m3/min m3/min dB(A) dB(A) dB(A) mm kg m3/min kW kW kW
A kW
A mm kg m3/min dB(A) dB(A) dB(A)
A
A mm m m o C o C
2.5
102
8.5
A +++
2.5
0.5 - 3.4
0.540
3.4(-10 o C)
3.4(-10 o C)
3.4(-10 o C)
2.4(-15 o C)
0.0(-10 o C)
1059
4.5
A +
3.4
1.2 - 4.6
0.770
9.4
0.016
0.17
600-750-215
15
3.9
- 4.9 - 5.9 - 7.1 - 8.2
3.9 - 5.1 - 6.2 - 7.7 - 9.7
20 - 25 - 30 - 35 - 39
19 - 25 - 30 - 35 - 41
49
550-800-285
37
31.3
33.6
46
51
59
9.2
10
6.35/9.52
20
12
-10 ~ +46
-15 ~ +24
MFZ-KJ25VE
MUFZ-KJ25VE
R410A (*1)
Inverter Heat Pump
MFZ-KJ35VE
MUFZ-KJ35VE
R410A (*1)
Outdoor power supply
230 / Single / 50
3.5
150
8.1
A ++
3.5
0.5 - 3.7
0.940
3.5(-10 o C)
3.5(-10 o C)
3.5(-10 o C)
2.9(-15 o C)
0.0(-10 o C)
1110
4.4
A +
4.3
1.2 - 5.5
1.100
9.4
0.016
0.17
600-750-215
15
3.9 - 4.9 - 5.9 - 7.1 - 8.2
3.9 - 5.1 - 6.2 - 7.7 - 9.7
20 - 25 - 30 - 35 - 39
19 - 25 - 30 - 35 - 41
50
550-800-285
37
31.3
33.6
47
51
60
9.2
10
6.35/9.52
20
12
-10 ~ +46
-15 ~ +24
MFZ-KJ50VE
MUFZ-KJ50VE
R410A (*1)
5.0
266
6.5
A ++
5.0
1.6 - 5.7
1.410
4.4(-10 o C)
4.4(-10 o C)
4.4(-10 o C)
6.0(-15 o C)
0.0(-10 o C)
1406
4.3
A +
6.0
2.2 - 8.2
1.610
14.0
0.038
0.34
600-750-215
15
5.6 - 6.7 - 8.0 - 9.3 - 10.6
6.0 - 7.4 - 9.4 - 11.6 - 14.0
27 - 31 - 35 - 39 - 44
29 - 35 - 40 - 45 - 50
56
880-840-330
55
45.8
45.8
49
51
63
13.6
16
6.35/12.7
30
15
-10 ~ +46
-15 ~ +24
(*1) Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere.
This appliance contains a refrigerant fluid with a GWP equal to 1975. This means that if 1 kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher than 1 kg of CO 2 , over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
(*2) Energy consumption based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
(
*3) SHi: Super High
(*4) SEER, SCOP and other related description are based on COMMISSION DELEGATED REGULATION (EU) No.626/2011. The temperature conditions for calculating SCOP are based on “Average Season”.
44
MLZ-KA25/35/50VA
MLZ
SERIES
Introducing a new type of ceiling cassette for the Multi-Split Series with streamed interior dimensions and a sharp, sleek appearance.
45
Ceiling Mounted
Installing the ceiling-mounted MLZ
Series unit in a room creates a more spacious feel that enhances room comfort. This overhead format is also an excellent solution when lighting equipment is installed at the centre of the room and fixtures such as book shelves are mounted on wall surfaces.
Access door not required
Slim Body
The new units are designed with a slim body (only 175mm high), ensuring easy installation even when low ceiling cavities limit installation space. The need for ceiling cavity service space is also eliminated, further reducing the dimensions required for installation.
175mm
Set Airflow According to Ceiling Height
Dual-level airflow selection is engineered to accommodate specific ceiling heights. This is a key feature for adjusting airflow effectively when it is either too strong or too weak due to being mismatched with the height of the ceiling.
Auto Vane Control
Outlet vanes can be moved left and right, and up and down using the remote controller. This improved airflow control feature solves the problem of drafts.
Standard
High ceiling
25
2.4m
2.7m
35
2.4m
2.7m
50
2.4m
2.7m
Left and Right
Up and Down
Easy Installation
A built-in drain pump (500mm lift) and flexible drain joints make attaching the drain hose in the ceiling cavity easy, resulting in simple and fast installation. Tight yet flexible fittings eliminate the need of wrapping with heat-insulation tape, and ensure that pipe and drain cover connections are free of condensation.
● Drain Piping Supporters
Easy joint connections!
Built-in drain pump secures drainage water lift of 500mm
Flexible drain joints
Insulating material wrapping only required from this point
Insulation material pretreatment eliminates need for wrapping.
The newly adopted insulation-free cover eliminates the need for wrapping pipes with insulation tape and prevents the forming of condensation.
Flexible drain joints simplify drain piping work in narrow ceiling areas
Installation Example
Refrigerant pipe
Drain cover
● Easy Mounting Plate
Suspension work simplified with well-designed mounting plates
Secure one side Push the unit to the other side
Secure the opposite side
Move unit to the centre
MLZ-KA
SERIES
Indoor Unit Outdoor Unit
For MXZ Connection Only
Remote Controller
MLZ-KA25/35/50VA
Panel
MLP-440W
Optional Optional Optional Optional
Optional
Type
Indoor Unit
Outdoor Unit
Refrigerant
Power
Supply
Source
Outdoor ( V / Phase / Hz )
Cooling
Design load
Annual electricity consumption (*2)
SEER
(*4)
Energy effi ciency class kW kWh/a
Heating
(Average
Season)
Capacity
Rated
Min-Max
Rated kW kW kW Total Input
Design load kW at reference design temperature kW
Declared
Capacity at bivalent temperature at operation limit temperature
Back up heating capacity kW kW kW
Annual electricity consumption (*2)
SCOP
(*4)
Energy effi ciency class kWh/a
Capacity
Rated
Min-Max
Rated Total Input
Operating Current (Max)
Input Rated
Operating Current(Max)
Indoor
Unit
Panel
Dimensions
Weight
H*W*D
Air Volume (SLo-Lo-
Mid-Hi-SHi (*3) (Dry/Wet))
Sound Level (SPL)
(SLo-Lo-Mid-Hi-SHi
(*3)
)
Cooling
Heating
Cooling
Heating
Sound Level (PWL) Cooling
Dimensions H*W*D
Weight
Dimensions
Weight
H*W*D
Outdoor
Unit
Ext.
Piping
Air Volume
Sound Level (SPL)
Cooling
Heating
Cooling
Heating
Sound Level (PWL) Cooling
Operating Current (Max)
Breaker Size
Diameter Liquid/Gas
Max.Length
Max.Height
Guaranteed Operating
Range (Outdoor)
Out-In
Out-In
Cooling
Heating dB(A) dB(A) mm kg mm kg m
3
/min m 3 /min kW kW kW
A kW
A mm kg m 3 /min m
3
/min dB(A) dB(A) dB(A) dB(A)
A
A mm
˚C
˚C m m
MLZ-KA25VA
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
0.4
0.040
-
175-1102-360
15
7.2-8.0-8.8
7.0-8.2-9.2
29-32-35
28-32-36
-
34-1200-414
3.5
-
-
-
-
-
-
-
-
-
6.35/9.52
-
-
-
-
Inverter Heat Pump
MLZ-KA35VA for MXZ connection
R410A
(*1)
Outdoor Power supply
230V / Single / 50Hz
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
0.4
0.040
-
175-1102-360
15
7.3-8.4-9.4
7.7-8.8-9.9
31-34-37
31-35-38
-
34-1200-414
3.5
-
-
-
-
-
-
-
-
-
6.35/9.52
-
-
-
-
MLZ-KA50VA
-
-
-
-
-
0.4
0.040
-
175-1102-360
15
8.3-9.8-11.4
8.8-10.3-11.8
34-38-43
34-39-43
-
34-1200-414
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
6.35/12.7
-
-
-
-
-
-
-
-
-
3.5
-
-
(*1) Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant fl uid with a GWP equal to 1975. This means that if 1 kg of this refrigerant fl uid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher than 1 kg of CO 2 , over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
(*2) Energy consumption based on standard test results.Actual energy consumption will depend on how the appliance is used and where it is located.
(*3) SHi: Super High
(*4) SEER, SCOP and other related description are based on COMMISSION DELEGATED REGULATION (EU) No.626/2011. The temperature conditions for calculating SCOP are based on “Average Season”.
46
47
Specification on Warmer Condition
Type
Indoor Unit
Outdoor Unit
Refrigerant
Cooling
Design load
Annual electricity consumption
(*2)
SEER
Energy efficiency class kW kWh/a
Heating
(Warmer
Season)
Design load
Declared
Capacity
Back up heating capacity
Annual electricity consumption
(*2)
SCOP kW at reference design temperature kW at bivalent temperature at operation limit temperature kW kW kW kWh/a
Energy efficiency class
MSZ-FH25VE
MUZ-FH25VE MUZ-FH25VEHZ
2.5
96
9.1
A+++
1.7 (2°C)
1.7 (2°C)
1.7 (2°C)
2.5 (-15°C)
0.0 (2°C)
376
6.3
A+++
2.5
96
9.1
A+++
1.8 (2°C)
1.8 (2°C)
1.8 (2°C)
1.7 (-25°C)
0.0 (2°C)
397
6.3
A+++
Inverter Heat Pump
MSZ-FH35VE
MUZ-FH35VE MUZ-FH35VEHZ
R410A (*1)
3.5
3.5
138
8.9
A+++
2.0 (2°C)
2.0 (2°C)
2.0 (2°C)
3.2 (-15°C)
0.0 (2°C)
429
6.5
A+++
138
8.9
A+++
2.2 (2°C)
2.2 (2°C)
2.2 (2°C)
2.6 (-25°C)
0.0 (2°C)
471
4.8 / 6.5
A+++
MSZ-FH50VE
MUZ-FH50VE MUZ-FH50VEHZ
5.0
244
7.2
A++
2.5 (2°C)
2.5 (2°C)
2.5 (2°C)
5.2 (-15°C)
0.0 (2°C)
614
5.7
A+++
5.0
244
7.2
A++
3.3 (2°C)
3.3 (2°C)
3.3 (2°C)
3.8 (-25°C)
0.0 (2°C)
787
5.9
A+++
Type
Indoor Unit
Outdoor Unit
Refrigerant
Design load
Cooling
Annual electricity consumption (*2)
SEER
Energy efficiency class kW kWh/a
Heating
(Warmer
Season)
Design load kW at reference design temperature kW
Declared
Capacity at bivalent temperature at operation limit temperature
Back up heating capacity kW kW kW
Annual electricity consumption (*2) kWh/a
SCOP
Energy efficiency class
MSZ-EF25VE2
MUZ-EF25VE MUZ-EF25VEH
2.5
103
8.5
A+++
1.3 (2°C)
1.3 (2°C)
1.3 (2°C)
2.0 (-15°C)
0.0 (2°C)
304
6.0
A+++
2.5
103
8.5
A+++
1.3 (2°C)
1.3 (2°C)
1.3 (2°C)
1.6 (-20°C)
0.0 (2°C)
304
6.0
A+++
Inverter Heat Pump
MSZ-EF35VE2
MUZ-EF35VE
R410A
MUZ-EF35VEH
(*1)
3.5
3.5
144
8.5
A+++
1.6 (2°C)
1.6 (2°C)
1.6 (2°C)
2.4 (-15°C)
0.0 (2°C)
396
5.7
A+++
144
8.5
A+++
1.6 (2°C)
1.6 (2°C)
1.6 (2°C)
1.7 (-20°C)
0.0 (2°C)
396
5.7
A+++
MSZ-EF42VE2
MUZ-EF42VE
4.2
192
7.7
A++
2.1 (2°C)
2.1 (2°C)
2.1 (2°C)
3.4 (-15°C)
0.0 (2°C)
491
6.0
A+++
MSZ-EF50VE2
MUZ-EF50VE
5.0
244
7.2
A++
2.3 (2°C)
2.3 (2°C)
2.3 (2°C)
3.5 (-15°C)
0.0 (2°C)
557
5.8
A+++
Type
Indoor Unit
Outdoor Unit
Refrigerant
Cooling
Design load
Annual electricity consumption (*2)
SEER
Energy efficiency class
Design load kW kWh/a
Heating
(Warmer
Season) kW
Declared
Capacity at reference design temperature kW at bivalent temperature at operation limit temperature
Back up heating capacity
Annual electricity consumption (*2)
SCOP kW kW kW kWh/a
Energy efficiency class
MSZ-SF25VE
MUZ-SF25VE MUZ-SF25VEH
2.5
116
7.6
A++
1.3 (2°C)
1.3 (2°C)
1.3 (2°C)
2.0 (-15°C)
0.0 (2°C)
337
5.4
A+++
2.5
116
7.6
A++
1.3 (2°C)
1.3 (2°C)
1.3 (2°C)
1.6 (-20°C)
0.0 (2°C)
337
5.4
A+++
Inverter Heat Pump
MSZ-SF35VE
MUZ-SF35VE MUZ-SF35VEH
R410A (*1)
MSZ-SF42VE
MUZ-SF42VE MUZ-SF42VEH
3.5
171
7.2
A++
1.6 (2°C)
1.6 (2°C)
1.6 (2°C)
2.2 (-15°C)
0.0 (2°C)
923 / 418
5.4
A+++
3.5
171
7.2
A++
1.6 (2°C)
1.6 (2°C)
1.6 (2°C)
1.6 (-20°C)
0.0 (2°C)
417
5.4
A+++
4.2
196
7.5
A++
2.1 (2°C)
2.1 (2°C)
2.1 (2°C)
3.4 (-15°C)
0.0 (2°C)
507
5.8
A+++
4.2
196
7.5
A++
2.1 (2°C)
2.1 (2°C)
2.1 (2°C)
2.2 (-20°C)
0.0 (2°C)
507
5.8
A+++
MSZ-SF50VE
MUZ-SF50VE MUZ-SF50VEH
5.0
246
7.2
A++
2.3 (2°C)
2.3 (2°C)
2.3 (2°C)
3.4 (-15°C)
0.0 (2°C)
563
5.7
A+++
5.0
246
7.2
A++
2.3 (2°C)
2.3 (2°C)
2.3 (2°C)
2.3 (-20°C)
0.0 (2°C)
563
5.7
A+++
Type
Indoor Unit
Outdoor Unit
Refrigerant
Cooling
Design load
Annual electricity consumption
(*2)
SEER
Energy efficiency class kW kWh/a
Heating
(Warmer
Season)
Design load
Declared
Capacity
Back up heating capacity
Annual electricity consumption
(*2)
SCOP (*4) kW
At reference design temperature kW at bivalent temperature at operation limit temperature kW kW kW kWh/a
Energy efficiency class
Inverter Heat Pump
MSZ-GF60VE MSZ-GF71VE
MUZ-GF60VE
R410A
MUZ-GF71VE
(*1)
6.1
7.1
311
6.8
A++
2.5 (2°C)
2.5 (2°C)
2.5 (2°C)
3.7 (-15°C)
0.0 (2°C)
664
5.3
A+++
364
6.8
A++
3.7 (2°C)
3.7 (2°C)
3.7 (2°C)
5.4 (-15°C)
0.0 (2°C)
963
5.4
A+++
Type
Indoor Unit
Outdoor Unit
Refrigerant
Design load
Cooling
Annual electricity consumption (*2)
SEER
Energy efficiency class kW kWh/a
Heating
(Warmer
Season)
Design load kW at reference design temperature kW
Declared
Capacity at bivalent temperature at operation limit temperature
Back up heating capacity kW kW kW
Annual electricity consumption (*2) kWh/a
SCOP
Energy efficiency class
MSZ-HJ25VA
MUZ-HJ25VA
2.5
171
5.1
A
1.1 (2°C)
1.1 (2°C)
1.1 (2°C)
1.9 (-10°C)
0.0 (2°C)
356
4.3
A+
Inverter Heat Pump
MSZ-HJ35VA
MUZ-HJ35VA
R410A
(*1)
3.1
212
5.1
A
1.3 (2°C)
1.3 (2°C)
1.3 (2°C)
2.4 (-10°C)
0.0 (2°C)
426
4.3
A+
MSZ-HJ50VA
MUZ-HJ50VA
5.0
292
6.0
A+
2.1 (2°C)
2.1 (2°C)
2.1 (2°C)
3.8 (-10°C)
0.0 (2°C)
539
5.5
A+++
(*1) Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant fluid with a GWP equal to 1975. This means that if 1 kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher than 1 kg of CO
2
, over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
(*2) Energy consumption based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
48

Download
Advertisement
Key features
Stylish design
High energy efficiency
Quiet operation
Low standby power
3 color options
MXZ compatibility
Frequently asked questions
The MSZ-EF25VE2W has a SEER rating of 8.5 and SCOP rating of 4.6, achieving A+++ for cooling and A++ for heating.
The Silent Mode feature allows the unit to operate as low as 21dB, comparable to the sound of rustling leaves.
The MSZ-EF25VE2W comes in white, silver, and black.
Yes, the MSZ-EF25VE2W is compatible with MXZ multi-system connection.