Intel. Server Board SE7500CW2 Product Guide


Add to my manuals
98 Pages

advertisement

Intel. Server Board SE7500CW2 Product Guide | Manualzz

Intel

®

Server Board SE7501CW2

Product Guide

A Guide for Technically Qualified Assemblers of Intel

®

Identified

Subassemblies/Products

Order Number: C29938-003

Safety Cautions

Read all caution and safety statements in this document before performing any of the instructions.

See also Intel Server Boards and Server Chassis Safety Information on the Resource CD and/or at http:\\support.intel.com

.

Wichtige Sicherheitshinweise

Lesen Sie zunächst sämtliche Warn- und Sicherheitshinweise in diesem Dokument, bevor Sie eine der Anweisungen ausführen. Beachten Sie hierzu auch die Sicherheitshinweise zu Intel-

Serverplatinen und -Servergehäusen auf der Ressourcen-CD oder unter http:\\support.intel.com

.

重要安全指导

在执行任何指令之前,请阅读本文档中的所有注意事项及安全声明。参见 Resource

CD(资源光盘) 和/或 http:\\support.intel.com

上的

Intel Server Boards and

Server Chassis Safety Information

(《Intel 服务器主板与服务器机箱安全信息》)。

Consignes de sécurité

Lisez attention toutes les consignes de sécurité et les mises en garde indiquées dans ce document avant de suivre toute instruction. Consultez Intel Server Boards and Server Chassis Safety

Information sur le CD Resource CD ou bien rendez-vous sur le site http:\\support.intel.com

.

Instrucciones de seguridad importantes

Lea todas las declaraciones de seguridad y precaución de este documento antes de realizar cualquiera de las instrucciones. Vea Intel Server Boards and Server Chassis Safety Information en el CD Resource y/o en http:\\support.intel.com

.

Disclaimer

Information in this document is provided in connection with Intel

®

products. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document. Except as provided in Intel’s Terms and Conditions of Sale for such products, Intel assumes no liability whatsoever, and Intel disclaims any express or implied warranty, relating to sale and/or use of Intel products including liability or warranties relating to fitness for a particular purpose, merchantability, or infringement of any patent, copyright or other intellectual property right. Intel products are not designed, intended or authorized for use in any medical, life saving, or life sustaining applications or for any other application in which the failure of the Intel product could create a situation where personal injury or death may occur. Intel may make changes to specifications and product descriptions at any time, without notice.

Intel, Intel Xeon, and EtherExpress are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the

United States and other countries.

*

Other names and brands may be claimed as the property of others.

Copyright © 2003, Intel Corporation. All Rights Reserved.

Contents

1 Description...................................................................................................... 7

Server Board Features............................................................................................................ 7

Back Panel Connectors.................................................................................................. 8

Server Board Connector and Component Locations...................................................... 9

Processor ..................................................................................................................... 10

Intel® E7501 Chipset ................................................................................................... 11

Super I/O ...................................................................................................................... 12

Memory 13

PCI Subsystem ............................................................................................................ 14

Video Controller............................................................................................................ 15

USB 16

Network Interface Controllers (NICs) ........................................................................... 17

ACPI 19

Wakeup Events ............................................................................................................ 19

Security 20

2 Configuration Software and Utilities .......................................................... 23

Power-On Self-Test (POST) ................................................................................................. 23

Using the BIOS Setup Utility ................................................................................................. 24

If You Cannot Access Setup ........................................................................................ 24

Starting Setup .............................................................................................................. 24

Setup Menus ................................................................................................................ 24

Menu Selection Bar ...................................................................................................... 26

Main Menu ................................................................................................................... 27

Advanced Menu ........................................................................................................... 29

Security Menu .............................................................................................................. 40

Power Menu ................................................................................................................. 41

Boot Menu .................................................................................................................... 42

System Menu ............................................................................................................... 43

Exit Menu ..................................................................................................................... 44

Upgrading the BIOS .............................................................................................................. 45

Preparing for the Upgrade............................................................................................ 45

Upgrading the BIOS ..................................................................................................... 46

Crisis Recovery Diskette .............................................................................................. 47

Changing the BIOS Language ..................................................................................... 49

Hardware Monitoring............................................................................................................. 49

3 Server Board Installations and Upgrades.................................................. 51

Tools and Supplies Needed .................................................................................................. 51

Before You Begin .................................................................................................................. 51

Emissions Disclaimer ................................................................................................... 51

Safety Cautions ............................................................................................................ 51

Safety and Regulatory Compliance....................................................................................... 52

Minimum Hardware Requirements........................................................................................ 53

Installation Notes................................................................................................................... 53

iii

Installation Procedures.......................................................................................................... 54

Installing the I/O Gasket and Shield ............................................................................. 54

Installing Chassis Standoffs ......................................................................................... 56

Installing the Server Board ........................................................................................... 58

Installing or Replacing Memory .................................................................................... 61

Installing or Replacing the Processor(s)....................................................................... 62

Replacing the Backup Battery ...................................................................................... 69

Making Connections to the Server Board..................................................................... 71

Routing Cables............................................................................................................. 72

Finishing Up ................................................................................................................. 74

4 Solving Problems ......................................................................................... 75

Resetting the System ............................................................................................................ 75

Initial System Startup ............................................................................................................ 75

Checklist ....................................................................................................................... 75

Running New Application Software....................................................................................... 76

Checklist ....................................................................................................................... 76

After the System Has Been Running Correctly ..................................................................... 76

Checklist ....................................................................................................................... 76

More Problem Solving Procedures ....................................................................................... 77

Preparing the System for Diagnostic Testing ............................................................... 77

Monitoring POST.......................................................................................................... 77

Verifying Proper Operation of Key System Lights ........................................................ 77

Confirming Loading of the Operating System .............................................................. 77

Specific Problems and Corrective Actions ............................................................................ 78

Power Light Does Not Light.......................................................................................... 78

No Characters Appear on Screen ................................................................................ 78

Characters Are Distorted or Incorrect........................................................................... 79

System Cooling Fans Do Not Rotate Properly ............................................................. 79

Diskette Drive Activity Light Does Not Light ................................................................. 79

CD-ROM Drive Activity Light Does Not Light ............................................................... 80

Cannot Connect to a Server......................................................................................... 80

Problems with Network................................................................................................. 80

PCI Installation Tips ..................................................................................................... 81

Problems with Application Software ............................................................................. 81

Bootable CD-ROM Is Not Detected.............................................................................. 81

Recovering the BIOS ............................................................................................................ 82

Recovering the BIOS with the Crisis Recovery Diskette .............................................. 82

Clearing the Password .......................................................................................................... 84

Clearing the CMOS ............................................................................................................... 85

5 Getting Help .................................................................................................. 87

6 Technical Reference .................................................................................... 89

Configuration Jumpers .......................................................................................................... 89

Front Panel Header............................................................................................................... 90

iv Intel Server Board SE7501CW2 Product Guide

7 Regulatory and Integration Information..................................................... 91

Product Regulatory Compliance ........................................................................................... 91

Product Safety Compliance.......................................................................................... 91

Product EMC Compliance ............................................................................................ 91

Product Regulatory Compliance Markings ................................................................... 92

Electromagnetic Compatibility Notices.................................................................................. 92

FCC (USA) ................................................................................................................... 92

Industry Canada (ICES-003) ........................................................................................ 93

Europe (CE Declaration of Conformity)........................................................................ 93

Taiwan Declaration of Conformity ................................................................................ 93

Korean RRL Compliance.............................................................................................. 94

Australia / New Zealand ............................................................................................... 94

Index ................................................................................................................... 95

Figures

Figure 1. Back Panel Connectors .......................................................................................... 8

Figure 2. Server Board Connector and Component Locations .............................................. 9

Figure 3. Server Chassis SC5250-E USB Port Knockout .................................................... 16

Figure 4. Attaching the Gasket to the I/O Shield.................................................................. 54

Figure 5. Attaching the Label to the I/O Shield .................................................................... 55

Figure 6. Installing the I/O Shield ......................................................................................... 55

Figure 7. Installing Chassis Standoffs in the SC5200 .......................................................... 56

Figure 8. Installing Chassis Standoffs in the SC5250-E ...................................................... 57

Figure 9. Placing the Server Board in the SC5200 Chassis ................................................ 58

Figure 10. Placing the Server Board in the SC5250-E Chassis........................................... 58

Figure 11. Attaching the Server Board to Server Chassis SC5200 ..................................... 59

Figure 12. Engaging the Server Chassis SC5250-E Snap-top Standoffs ............................ 59

Figure 13. Attaching the Server Board to Server Chassis SC5250-E.................................. 60

Figure 14. Installing Memory................................................................................................ 61

Figure 15. Opening Socket Lever and Attaching Processor ................................................ 63

Figure 16. Attaching Retention Mechanism ......................................................................... 64

Figure 17. Applying Thermal Grease ................................................................................... 64

Figure 18. Attaching the Heat Sink and Retention Clip........................................................ 65

Figure 19. Attaching the Fan Case to the Wind Tunnel ....................................................... 66

Figure 20. Attaching the Heat Sink Fan to the PWT ............................................................ 66

Figure 21. Attaching the Top Assembly to the Retention Mechanism ................................. 67

Figure 22. Processor and Wind Tunnel Installed ................................................................. 68

Figure 23. Replacing the Backup Battery............................................................................. 70

Figure 24. Making Connections to the Server Board ........................................................... 71

Figure 25. Routing IDE Cables ............................................................................................ 72

Figure 26. Routing the Floppy Drive Cable .......................................................................... 73

Figure 27. Making Back Panel Connections ........................................................................ 74

Figure 28. BIOS Recovery Jumper ...................................................................................... 83

Figure 29. Password Recovery Jumper ............................................................................... 84

Figure 30. CMOS Recovery Jumper .................................................................................... 85

Figure 31. Configuration Jumper Location ........................................................................... 89

Figure 32. Front Panel Header Connection Location........................................................... 90

Tables

Table 1.

Table 2.

Table 3.

Table 4.

Table 5.

Table 6.

Table 7.

Table 8.

Server Board Features .................................................................................... 7

10/100 Megabit LEDs (NIC1) ........................................................................ 18

Gigabit LEDs (NIC2)...................................................................................... 18

Security Operation Summary ........................................................................ 20

Configuration Utilities..................................................................................... 23

Keyboard Commands.................................................................................... 25

On-Screen Options........................................................................................ 26

Menu Selection Bar ....................................................................................... 26

Table 9.

Main Menu..................................................................................................... 27

Table 10.

Primary/Secondary, Master/Slave Submenu................................................. 28

Table 11.

Advanced Menu............................................................................................. 29

Table 12.

I/O Device Configuration Submenu ............................................................... 31

Table 13.

On Board Device Submenu........................................................................... 33

Table 14.

PCI Configuration Submenu.......................................................................... 34

Table 15.

Onboard NICs Submenu ............................................................................... 35

Table 16.

Option ROM Scan Submenu ......................................................................... 35

Table 17.

Server Menu Submenu.................................................................................. 36

Table 18.

Console Redirection Submenu...................................................................... 37

Table 19.

DMI Event Logging Submenu........................................................................ 38

Table 20.

Hardware Monitor Submenu.......................................................................... 39

Table 21.

Security Menu................................................................................................ 40

Table 22.

Power Menu .................................................................................................. 41

Table 23.

Boot Menu ..................................................................................................... 42

Table 24.

System Menu................................................................................................. 43

Table 25.

Exit Menu....................................................................................................... 44

Table 26.

Monitored Headers and Sensors................................................................... 49

Table 28.

Configuration Jumper (J32) ........................................................................... 89

Table 29.

Front Panel Header Connection Descriptions ............................................... 90

Table 30.

Product Certification Markings....................................................................... 92

vi Intel Server Board SE7501CW2 Product Guide

1 Description

Server Board Features

The Intel

®

Server Board SE7501CW2 offers a “flat” design, with the processors and memory subsystems residing on the board. The server board supports dual-processor operation with

Intel

®

Xeon

processors and the Intel

®

E7501 chipset. The board contains embedded devices for video, network, and IDE, and provides basic monitoring hardware and interrupt control for dual processors and PC/AT

*

-compatible operation.

Table 1. Server Board Features

Feature Description

Processor Dual Intel Xeon processors for the Intel socket 604 that use the Flip Chip Pin Grid

Array (FC-PGA) package

Chipset

Memory

Video

Intel E7501 chipset:

Supports 533 MHz Front Side Bus (FSB), backwards compatible with 400 MHz

FSB

Memory Controller Hub (MCH) (North Bridge)

I/O Controller Hub 3 (ICH3-S) (South Bridge)

P64H2 64-bit I/O hub

FWH firmware hub

DDR200 / 266 compliant ECC DIMMs providing up to 8 GB of memory

1

DIMM Sockets: Four 72-bit, 184-pin, gold contact

Supported DIMM sizes: 128, 256, 512 MB, 1 GB, and 2 GB

Support for single channel, Error Correcting Code (ECC), registered, DDR200 or

DDR266 DIMMs

Integrated onboard ATI Rage

*

XL 64-bit SVGA video controller

8 MB SDRAM video memory

SVGA video port

PCI bus Five PCI expansion slots for add-in boards:

One 64-bit, PCI-X 133 MHz expansion slot

Two 64-bit, PCI-X 100 MHz expansion slots

Two 32-bit, 33 MHz, PCI expansion slots

Hard Disk Drive (HDD)

Two IDE connectors supporting up to four ATA-100 compatible devices

Network Dual integrated on-board Ethernet connections:

Intel

®

PRO 10/100 Fast Ethernet Controller (Intel

®

82550PM)

Intel

®

PRO Gigabit Ethernet Controller (Intel

®

82540EM) continued

1

DDR200 compliant ECC DIMMs can be used only if 400 MHz processors are installed.

7

Table 1.

Server Board Features (continued)

Feature Description

System I/O

Winbond

*

W83627HF Super I/O Controller (Low Pin Count [LPC] bus) that provides the following:

Hardware monitoring

PS/2

*

-compatible keyboard and mouse ports, 6-pin DIN

Advanced parallel port, supporting Enhanced Parallel Port (EPP) level 1.7 and 1.9, Extended Capabilities Port (ECP), compatible 25-pin

One serial port, 9-pin

Three Universal Serial Bus (USB) ports, with an additional USB header that provides optional front panel USB support for up to 2 USB connections

Power

Security

Form Factor

Two Ethernet controllers via RJ45 connectors: one Intel Fast Ethernet 82550PM, one Intel Gigabit 82540EM

SSI-EEB 3.0 compliant

Power/Sleep Switch with LED Indicator

Wake on LAN

*

(WOL)

Wake on Ring (WOR)

BIOS password

Keyboard password protection

SSI-EEB 3.0–compliant form factor

Back Panel Connectors

8

USB

A B

E

C D F G

A. USB 1, 2, 3

B. Keyboard/mouse

C. Serial port A

D. Video

E. Parallel

G. NIC2 (1 Gb)

Figure 1. Back Panel Connectors

TP00094

Intel Server Board SE7501CW2 Product Guide

Server Board Connector and Component Locations

A B C D E

Main Power

F

BB

AA

Z

Y

X

W

V

U

T S R Q P

A. Main power connector

B. Auxiliary signal connector

C. CPU power connector

D. CPU1 fan header

F. Primary processor socket (CPU1)

G. Secondary processor socket (CPU2)

H. CPU2 fan header

I. System fan 2 header

J. System fan 1 header

K. Front panel header

TP00087

O. System fan 5 header

P. Battery

Q. Floppy drive connector

R. Front USB header

S. Serial port B header

T. Chassis Intrusion header

U. PCI 32/33 slots

V. PCI-X 64/100 slots

W. PCI-X 64/133 slot

X. System fan 4 header

Y. System fan 3 header

M. Secondary IDE connector (ATA 100)

N. Primary IDE connector (ATA 100)

AA. Jumper block

BB. Back panel connectors

Figure 2. Server Board Connector and Component Locations

NOTE

Bank 1 (DIMMs 1A and 1B) are closest to the side of the board and Bank 2

(DIMMs 2A and 2B) are closer to the middle of the board.

M

N

O

G

H

J

I

K

L

Description 9

Processor

The Intel

®

Server Board SE7501CW2 accommodates one or two Intel Xeon processors with 512KB

L2 cache via two SKT604 604-pin zero-insertion force (ZIF) sockets. The processors interface with the system bus at 533 MHz and are backwards compatible to 400 MHz. When only one processor is installed, it should be in the socket labeled CPU1.

For a complete list of supported processors, see:

http://support.intel.com/support/motherboards/server/SE7501CW2

Dual Processor Operation

The Intel Xeon processor interface is dual processor (DP) ready. Each processor contains a local

Intel

®

Advanced Programmable Interrupt Controller (APIC) section for interrupt handling. When two processors are installed, both processors must be of identical revision, core voltage, and bus/core speeds.

Boxed Processor Fan Heat Sink

A processor wind tunnel is supplied with the boxed Intel Xeon processor. After the processor and heat sink are installed, install and connect the processor wind tunnel. For proper processor cooling, the fan inlet air temperature should be below 45 °C.

NOTE

Heat sink styles vary. If your heat sink has a flat end, the flat surface must be installed so that it faces the rear of the chassis. See the installation instructions in Chapter 3.

CAUTION

Clearance is required at each end of the fan heat sink to ensure unimpeded airflow for proper cooling. Restricting the airflow through the processor heat sink can cause overheating and subsequent failure of the processor.

10 Intel Server Board SE7501CW2 Product Guide

Intel

®

E7501 Chipset

The Server Board SE7501CW2 includes the Intel E7501 chipset (MCH, ICH3-S, P64H2), which provides an integrated I/O bridge and memory controller, and a flexible I/O subsystem core (PCI).

MCH

The E7501 MCH North Bridge in the E7501 chipset integrates three main functions:

An integrated high-performance main memory subsystem

An HI 2.0 bus interface that provides a high-performance data flow path between the host bus and the I/O subsystem

A HI 1.5 bus that provides an interface to the ICH3-S (South Bridge)

Other features provided by the MCH include the following:

Full support of ECC on the memory bus

Full support of Intel

®

x4 Single Device Data Correction on the memory interface with x4

DIMMs

Twelve deep in-order queue

Full support of registered DDR200 or DDR266 ECC DIMMs

2

Support for up to 8 GB of DDR memory

Memory scrubbing

ICH3-S I/O Controller Hub

The primary role of the ICH3-S is to provide the gateway to all PC-compatible I/O devices and features. The Server Board SE7501CW2 uses the following ICH3-S features:

32-bit/33 MHz PCI bus interface

Low Pin Count (LPC) bus interface

IDE interface, with Ultra DMA 100 capability

Universal Serial Bus (USB) interface

PC-compatible timer/counter and DMA controllers

APIC and 8259 interrupt controller

Power management

System real-time clock (RTC)

General purpose I/O

2

DDR200 compliant ECC DIMMs can be used only if 400 MHz processors are installed.

Description 11

Super I/O

The Server Board SE7501CW2 uses the Winbond W83627HF Super I/O Plug and Play Compatible with ACPI-Compliant Controller/Extender. This device provides the system with the following:

Two serial ports

One parallel port

Floppy disk controller

PS/2-compatible keyboard and mouse controller

Two ATA 100 IDE channels

Hardware monitor controller

The server board provides the connector interface for the floppy disk drive, dual serial ports, parallel port, PS/2 mouse, and PS/2 keyboard.

Serial Ports

The server board provides one DB9 connector on the back panel for serial port A. Serial port A is compatible with 16550A and 16450 modes. The port can be set to one of four different COM ports, and each can be enabled separately. When enabled, each port can be programmed to generate edge- or level-sensitive interrupts. When disabled, serial port interrupts are available to add-in cards.

A DH10 10-pin serial header is available on the baseboard for an optional serial port B.

Parallel Port

The Server Board SE7501CW2 provides a 25-pin parallel port back panel connector. The Super

I/O provides an IEEE 1284–compliant 25-pin bidirectional parallel port. BIOS programming of the

Super I/O registers enables the parallel port and determines the port address and interrupt. When disabled, the interrupt is available to add-in cards.

Floppy Disk Connector

The floppy disk connector on the server board provides the interface to the floppy disk drive from the floppy disk controller.

Keyboard and Mouse Connectors

The separate keyboard and mouse connectors, found on the back panel of the server board, are

PS/2-compatible. The keyboard and mouse connectors are interchangeable.

12 Intel Server Board SE7501CW2 Product Guide

Memory

The Server Board SE7501CW2 contains four 184-pin DIMM sockets and provides up to 8 GB of memory. Memory is partitioned as two banks of DDR DIMMs, each of which provides 144 bits of two-way interleaved memory.

The server board supports up to four ECC DDR DIMMs that are compliant with the JEDEC

DDR200 / 266 specification. A range of DIMM sizes is supported, including the following:

128 MB

256 MB

512 MB

1 GB

2 GB

The minimum supported memory configuration is 128 MB with a single 128 MB DIMM in the

Bank 1, DIMM 1A socket. When two DIMMS are used, the minimum memory configuration is

256 MB, with Bank 1 fully populated by two 128 MB DIMMs. For a list of supported memory, see

http://www.intel.com/support/motherboards/server/SE7501CW2/

For maximum performance and data protection, each bank should be fully populated with two

DIMMs. For cost conscious designs, the system can be operated when Bank 1 contains a single

DIMM. When a single DIMM is used, it must be in the DIMM 1A socket. If only a single DIMM is populated in Bank 1, then interleaving and Intel® x4 Single Device Data Correction are unavailable.

Bank 2 can only operate with two DIMMs installed. Before Bank 2 can be used, Bank 1 must be fully populated (DIMMs installed in both Bank 1 sockets).

DIMMs must be installed in pairs and must be populated starting with DIMM 1A and 1B (see

Figure 14 on page 61 for the locations of the DIMM connectors). Although the Server Board

SE7501CW2 architecture allows the user to mix various sizes of DIMMs between banks, DIMMs must be identical within the banks.

Description 13

PCI Subsystem

The Server Board SE7501CW2 provides three PCI bus segments:

One PCI-X 64-bit / 133 MHz slots (Slot 1) on Bus C of the MCH

Two PCI-X 64-bit / 100 MHz slots (Slot 2 and 3) on Bus B of the MCH

Two PCI 32-bit / 33 MHz slots (Slot 4 and 5) on the ICH3-S

64-bit / 133 MHz PCI-X Capable Subsystem

The 64-bit/133 MHz PCI-X segment includes one 3.3 V keyed PCI expansion slot (slot 1) that can support PCI-X add-in cards up to 133 MHz and are backward compatible to 64 bit/66 MHz,

64 bit/33 MHz, and 32 bit/33 MHz PCI cards. This slot can be used for a riser card if this board is integrated into a high-density chassis.

64-bit/133 MHz PCI-X features include:

Bus speed up to 133 MHz

3.3 V signaling environment

Burst transfers up to a peak of 1000 megabytes per second (MB/s)

8-, 16-, 32-, 64-, or 100-bit data transfers

Plug and Play ready

Parity enabled

NOTE

The speed of the bus will run at the speed of the adapter installed.

64-bit / 100 MHz PCI-X Capable Subsystem

The 64-bit/100 MHz PCI-X segment includes two 3.3 V keyed PCI expansion slots (PCI-X slots 2 and 3) that can support add-in cards up to 100 MHz and are backward compatible to 64-bit/66 MHz,

64 bit/33 MHz, and 32 bit/33 MHz PCI cards.

64-bit/100 MHz PCI-X features include:

Bus speed up to 100 MHz

3.3 V signaling environment

Burst transfers up to a peak of 800 Megabytes per second (MB/s)

8-, 16-, 32-, or 64-bit data transfers

Plug and Play ready

Parity enabled

NOTE

If you install a slower card into one of the PCI-X 64/100 connectors, the bus speed for both connectors will be lowered to the speed of the slowest adapter.

14 Intel Server Board SE7501CW2 Product Guide

32-bit/33 MHz PCI Subsystem

The 32-bit/33 MHz PCI segment includes the following embedded devices and connectors:

Two 5 V keyed PCI expansion slots (slots 4 and 5)

Integrated Intel Gigabit Ethernet Controller (Intel 82540EM)

Integrated Intel 10/100 Fast Ethernet Controller (Intel 82550PM)

Integrated ATI Rage XL video controller with 8 MB of on-board SDRAM

32-bit/33 MHz PCI features include:

Bus speed up to 33 MHz

5 V signaling environment

Burst transfers up to a peak of 132 MB/s

8-, 16-, or 32-bit data transfers

Plug and Play ready

Parity enabled

Video Controller

The Server Board SE7501CW2 includes an ATI Rage XL video controller, 8 MB video SDRAM, and support circuitry for an embedded SVGA video subsystem.

The SVGA subsystem supports a variety of modes: up to 1600 x 1200 resolution for CRT displays and up to 1024 x 768 resolution for TFT displays, and up to 16.7 million colors. The server board provides a standard 15-pin VGA connector.

Description 15

USB

The Server Board SE7501CW2 contains three USB host controllers, supporting a total of five USB ports, depending on the chassis used. Regardless of the Intel

®

chassis used, three USB ports are accessible from the rear of the chassis.

In the Intel

®

Server Chassis SC5200, one additional USB port is accessible from the front of the system, behind the locking door.

The Server Chassis SC5250-E two additional USB ports at the front of the chassis. These are at the bottom left corner of the chassis. This chassis ships with a plastic knockout tab covering the lower

USB port. See Figure 3. Gently twist the plastic knockout tab from the chassis to access the lower

USB port.

USB support to all ports can be enabled / disabled through the BIOS setup screens. When it is enabled, the ports are initialized during POST and the BIOS looks for and enables the USB keyboard, mouse, boot device, and / or USB hub.

16

TP00262

Figure 3. Server Chassis SC5250-E USB Port Knockout

Intel Server Board SE7501CW2 Product Guide

Network Interface Controllers (NICs)

The Intel

®

Server Board SE7501CW2 includes one 10/100Base-TX network connection, based on the Intel 82550PM Fast Ethernet Controller (NIC1), and one 10/100/1000Base-TX network connection, based on Intel 82540EM Gigabit Ethernet Controller (NIC2). Facing the rear of the system, the 10/100 megabit controller (NIC1) is on the left, next to the video connector.

You can disable the embedded NICs in BIOS Setup Utility. When disabled, the controller(s) are not visible to the operating system.

NOTE

To ensure EMC (Electromagnetic Compatibility) product regulation compliance, the system must be used with a shielded LAN cable.

Supported Network Features

The server board supports the following features of the 82550PM controller (NIC1):

Glueless 32-bit PCI, CardBus master interface (Direct Drive of Bus), compatible with PCI

local Bus Specification, Revision 2.2

Integrated IEEE 802.3 10Base-T and 100Base-TX compatible PHY

IEEE 820.3u auto-negotiation support

Full duplex support at both 10 Mbps and 100 Mbps operation

Integrated UNDI ROM support

MDI/MDI-X and HWI support

Low power +3.3 V device

The server board supports the following features of the 82540EM controller (NIC2):

Support for the 33/66MHz bus segment

Integrated 10/100/1000 Mb/s full and half duplex operation

SMBUS ASF 1.0, ACPI, Wake On LAN, and PXE management functions

Compliant with PCI Power Management v1.1 and ACPI v2.0

Description 17

NIC Connector and Status LEDs

The Intel

®

Server Board SE7501CW2 supports two RJ45 connectors, one for the 10/100-Megabit

Fast Ethernet controller (NIC1), and the other for the Gigabit Ethernet controller (NIC2). You can disable the embedded NICs in the BIOS Setup Utility. Disabled NIC are not visible to the operating system.

NIC1 drives two LEDs on its RJ45 connector. These LEDs indicate link/activity on the LAN and the speed of operation. The green LED to the right of the connector indicates a network connection is in place when it is on and transmit/receive activity when it is blinking. The green LED to the left of the connector indicates 10 Mbps operation when it is off and100 Mbps operation when it is lit.

See the following table for an overview.

Table 2. 10/100 Megabit LEDs (NIC1)

LED Color LED State NIC1 State

Off 10-Mbps

Green (left)

On 100-Mbps

On On

Green (right)

Blinking Transmit / Receive activity

NIC2 drives two LEDs located on its RJ45 connector; this connector is on right side when looking at the I/O area in the back of the board. The green LED to the right of the connector indicates a network connection is in place when it is on, and transmit/receive activity when it is blinking. The bi-color LED to the left of the connector indicates 10-Mbps when it is off, 100-Mbps operation when it is green, and 1000-Mbps operation when it is yellow. See the following table for an overview.

Table 3. Gigabit LEDs (NIC2)

LED Color LED State NIC2 State

Off 10-Mbps

Green/Yellow (left)

Green (right)

Green 100-Mbps

Yellow 1000-Mbps

On On

Blinking Transmit / Receive activity

18 Intel Server Board SE7501CW2 Product Guide

ACPI

The Advance Configuration and Power Interface (ACPI)–aware operating system can place the system into a state where the hard drives spin-down, the system fans stop, and all processing is halted. In this state the power supply is still on and the processors still dissipate some power, so the power supply fan and processor fans are still running.

NOTE

ACPI requires an operating system that supports this feature.

The Server Board SE7501CW2 supports sleep states S0, S4, and S5. When the server board is operating in ACPI mode, the operating system retains control of the system and the operating system policy determines the entry methods and wake-up sources for each sleep state. Sleep entry and wake-up event capabilities are provided by the hardware but are enabled by the operating system. Following is a summary of the supported sleep states:

S0: Normal running state.

S4: Hibernate or Save to Disk. The memory and machine state are saved to disk. Pressing the power button or another wake-up event restores the system state from the disk and resumes normal operation. This state assumes that no hardware changes were made to the system while it was off.

S5: Soft off. Only the RTC section of the chipset is running in this state.

CAUTION

The system is off only when the AC power is disconnected.

AC Link Mode

The AC link mode allows the system to monitor its AC input power so that if AC input power is lost and then restored, the system returns to one of the following preselected settings:

Last State (Factory Default Setting)

Stay Off

The AC link mode settings can be changed by running the BIOS Setup Utility.

Wakeup Events

The server board supports Wake on LAN and Wake on Ring wakeup events.

Wake on LAN

Wake on LAN allows system power to be activated through the network. If the system is in the S4 state, it can be turned on remotely by sending a specific packet to the remote system. The system contains a configuration option that allows the on-board NICs to be enabled to wake the system from a S4 or S5 sleep state, even if the operating system disabled.

Description 19

Wake on Ring

Wake on Ring allows system power to be activated through the serial ports when this option is enabled in Setup. If the system is in the S4 state, it can be turned on remotely by the Ring Indicate

RI signals from the serial ports.

Security

The Server Board SE7501CW2 BIOS provides the ability to secure itself. Table 4 summarizes the

security options available in the BIOS.

Table 4. Security Operation Summary

Mode

Entry Method/

Event

Entry

Criteria

User

Password on boot

(AT style)

Power On/Reset User password set and password on boot enabled

Behavior

System halts for

User Password before booting. The system is not in secure mode.

Except for the password, no mouse or keyboard input is accepted.

Exit Criteria

User password followed by

[Enter]

After Exit

Power and Reset switches are enabled.

Keyboard and mouse inputs are accepted. The system boots normally. Boot sequence is determined by setup options.

Password Protection

The BIOS uses passwords to prevent unauthorized tampering with the system. Once secure mode is entered, access to the system is allowed only after the correct password(s) has been entered.

Both user and supervisor passwords are supported by the BIOS. The user password cannot be set unless a supervisor password has been set.

When set, a password can be cleared by changing it to a null string. Clearing the supervisor password also clears the user password. Entering the user password permits modification of the time, date, language, user password, and password on boot setup fields; other setup fields can be modified only if the supervisor password is entered. The user password also allows the system to boot, if secure boot is enabled.

If a wrong password is entered three times in a row, the BIOS stops validating passwords and the

BIOS security engine returns a failure for any further password validation attempt. If the user enters three wrong passwords in a row during the boot sequence (i.e., when entering Setup), the system is placed into a halt state. This feature makes is difficult to break the password by the “trial and error” method.

20 Intel Server Board SE7501CW2 Product Guide

Using Passwords

If only the supervisor password is set, you:

Must enter the supervisor password to enter BIOS Setup.

Must enter the supervisor password to boot the server if Password on Boot is enabled in the

BIOS Setup.

Must enter the supervisor password to exit secure mode.

If both passwords are set, you:

May enter the user password to enter BIOS Setup. However, you will not be able to change many of the options.

Must enter the supervisor password if you want to enter BIOS Setup and have access to all of the options.

May enter either password to boot the server if Password on Boot is enabled in the BIOS Setup.

May enter either password to exit secure mode.

Password Clear Jumper

If the user or supervisor password(s) is (are) lost or forgotten, booting the system with the password clear jumper into the “clear” position clears both passwords. The password clear jumper must be restored to its original position before a new password(s) can be set. The password clear jumper is located on jumper block J32 pins [1-2] on the Server Board SE7501CW2.

Description 21

22 Intel Server Board SE7501CW2 Product Guide

2 Configuration Software and Utilities

This chapter describes the Power-On Self-Test (POST) and server configuration utilities. Table 5

briefly describes the utilities.

Table 5. Configuration Utilities

BIOS Setup

Page

24

BIOS Upgrade

Utility

If the system does not have a diskette drive or the drive is disabled or misconfigured, use BIOS Setup to enable it.

Or, you can move the CMOS jumper on the server board from the default setting (Protect CMOS memory) to the Clear setting; this position will allow most server configurations to boot. Then use the recovery disk to recover.

Use to upgrade the BIOS.

45

Power-On Self-Test (POST)

Each time you turn on the system, the BIOS begins executing the Power-On Self-Test (POST), which is stored in flash memory. POST discovers, configures, and tests the processors, memory, keyboard, and most installed peripheral devices. During the memory test, POST displays the amount of memory that it is able to access and test. The time needed to test memory depends on the amount of memory installed.

1. Turn on your video monitor and server. After a few seconds POST begins to run.

2. After the memory test, these screen prompts and messages appear:

Press <F2> key if you want to run SETUP

3. If you do not press <F2> and do NOT have a device with an operating system loaded, the above message remains for a few seconds while the boot process continues, and the system beeps once. Then this message appears:

Operating system not found

4. Press <Esc> during POST to pop up a boot menu when POST finishes. From this menu you can choose the boot device or enter BIOS Setup.

What appears on the screen after this depends on whether you have an operating system loaded and if so, which one.

If the system halts before POST completes running, it emits a beep code indicating a fatal system error that requires immediate attention. If POST can display a message on the video display screen, it causes the speaker to beep twice as the message appears.

Note the screen display and write down the beep code you hear; this information is useful for your service representative. For a listing of common beep codes and error messages that POST can generate, see the “Solving Problems” chapter in this manual.

23

Using the BIOS Setup Utility

This section describes the BIOS Setup Utility options. Use BIOS Setup to change the server configuration defaults. You can run BIOS Setup with or without an operating system being present.

If You Cannot Access Setup

If you are not able to access BIOS Setup, you might need to clear the CMOS memory. For

instructions on clearing the CMOS, see Clearing the CMOS on page 85.

Starting Setup

You can enter and start BIOS Setup under several conditions:

When you turn on the server, after POST completes the memory test

When you have moved the CMOS jumper on the server board to the “Clear CMOS” position

(enabled)

In the two conditions listed above, after rebooting, you will see this prompt:

Press <F2> to enter SETUP

In a third condition, when CMOS/NVRAM has been corrupted, you will see other prompts but not the <F2> prompt:

Warning: CMOS checksum invalid

Warning: CMOS time and date not set

In this condition, the BIOS will load default values for CMOS and attempt to boot.

Setup Menus

Each BIOS Setup menu page contains a number of features. Except those used for information purposes, each feature is associated with a value field that contains user-selectable parameters.

Parameters may be changed depending upon the security option chosen. If a value is not changeable due to insufficient security privileges (or other reasons), the feature’s value field becomes inaccessible.

The bottom portion of the BIOS Setup screen provides a list of commands that are used for

navigating the Setup utility. Table 6 describes the keyboard commands you can use in the BIOS

Setup menus.

24 Intel Server Board SE7501CW2 Product Guide

Table 6. Keyboard Commands

Press Description

<F1>

F5/-

Help - Pressing F1 on any menu invokes the general Help window.

The left and right arrow keys are used to move between the major menu pages. The keys have no affect if a submenu or pick list is displayed.

Select Item up - The up arrow is used to select the previous value in a menu item’s option list, or a value field pick list. Pressing the Enter key activates the selected item.

Select Item down - The down arrow is used to select the next value in a menu item’s option list, or a value field pick list. Pressing the Enter key activates the selected item.

Change Value - The minus key or the F5 function key is used to change the value of the current item to the previous value. This key scrolls through the values in the associated pick list without displaying the full list.

F6/+ Change Value - The plus key or the F6 function key is used to change the value of the current menu item to the next value. This key scrolls through the values in the associated pick list without displaying the full list. On 106-key Japanese keyboards, the plus key has a different scan code than the plus key on the other keyboard, but it has the same effect.

<Enter> Execute Command - The Enter key is used to activate submenus when the selected feature is a submenu, or to display a pick list if a selected feature has a value field, or to select a sub-field for multi-valued features like time and date. If a pick list is displayed, the Enter key will undo the pick list, and allow another selection in the parent menu.

<Esc> Exit - The ESC key provides a mechanism for backing out of any field. This key will undo the pressing of the Enter key. When the ESC key is pressed while editing any field or selecting features of a menu, the parent menu is re-entered. When the ESC key is pressed in any submenu, the parent menu is re-entered. When the ESC key is pressed in any major menu, the exit confirmation window is displayed and the user is asked whether changes can be discarded.

<F9> Setup Defaults - Pressing F9 causes the following to appear:

<F10>

Setup Confirmation

Load default configuration now?

[Yes] [No]

If “Yes” is selected and the Enter key is pressed, all Setup fields are set to their default values. If

“No” is selected and the Enter key is pressed, or if the ESC key is pressed, the user is returned to where they were before F9 was pressed without affecting any existing field values.

Save and Exit - Pressing F10 causes the following message to appear:

Setup Confirmation

Save Configuration changes and exit now?

[Yes] [NO]

If “Yes” is selected and the Enter key is pressed, all changes are saved and Setup is exited. If

“No” is selected and the Enter key is pressed, or the ESC key is pressed, the user is returned to where they were before F10 was pressed without affecting any existing values.

Server Board Installation 25

Table 7 describes the on-screen options you will see in BIOS Setup and what they mean.

Table 7. On-Screen Options

When you see this:

On screen, an option is shown but you cannot select it or move to that field.

On screen, the phrase Press Enter appears next to the option.

What it means:

You cannot change or configure the option in that menu screen.

Either the option is auto-configured or auto-detected, or you must use a different Setup screen.

Press <Enter> to display a submenu that is either a separate full screen menu or a popup menu with one or more choices.

The following sections describe the menus and options available in BIOS Setup. Default settings are indicated in bold.

Menu Selection Bar

The Menu Selection Bar is located at the top of the screen and displays the major menu selections available to the user. The menu bar is shown below.

Main Advanced Security Power Boot System Exit

Table 8 lists the menus available in BIOS Setup.

Table 8. Menu Selection Bar

Allocates resources for hardware components

Configures advanced features available through the chipset

Sets and clears passwords and security features

Allows system to disable ACPI reboot and disable power button

Selects boot options and power supply controls

Information on vendor, processor, memory, peripherals, and BIOS

Saves or discards changes to

Setup program options

26 Intel Server Board SE7501CW2 Product Guide

Main Menu

To access this menu, select Main on the menu bar at the top of the screen.

Main

Advanced Security Power

Primary Master

Primary Slave

Secondary Master

Secondary Slave

Boot System Exit

Table 9 lists the options available on the Main menu. This menu allocates resources for hardware

components.

Table 9. Main Menu

Feature Choices Description

System Time

System Date

Legacy Diskette A

HH:MM:SS

MM/DD/YYYY

Disabled

1.44 MB, 3 ½

(default)

Sets the system time (hour, minutes, and seconds, on a 24-hour clock).

Sets the system date (month, day, year).

Selects the diskette type.

Primary Master

Primary Slave

Secondary Master

Secondary Slave

Select to display submenu

Select to display submenu

Select to display submenu

Select to display submenu

Displays IDE device selection.

Displays IDE device selection.

Displays IDE device selection.

Displays IDE device selection.

Server Board Installation 27

Primary/Secondary, Master/Slave Submenus

To access this submenu, select Main on the menu bar at the top of the screen and then the master or slave to be configured.

Main

Advanced Security Power

Primary Master

Boot System Exit

Primary Slave

Secondary Master

Secondary Slave

There are four IDE submenus: primary master, primary slave, secondary master, and secondary

slave. Table 10 shows the format of the IDE submenus. For brevity, only one example is shown.

Table 10. Primary/Secondary, Master/Slave Submenu

Type

Multi-Sector Transfers

LBA Mode Control

32 Bit I/O

Transfer Mode

Ultra DMA Mode

No options

No options

No options

Automatically detects the type of IDE device installed.

Specifies the number of sectors that are transferred per block during multiple sector transfers. This option is disabled by default.

Enables Large Block Addressing (LBA) instead of cylinder, head, sector addressing. This option is disabled by default.

Enables 32-bit IDE data transfers.

Disabled (default)

Enabled

No options

No options

Selects the method of moving data to and from the hard drive. Automatically set to Standard, which selects the optimum transfer mode.

Enables Ultra DMA mode.

28 Intel Server Board SE7501CW2 Product Guide

Advanced Menu

To access this menu, select Advanced on the menu bar at the top of the screen.

Main

Advanced

Security Power

I/O Device Configuration

On Board Device

Boot System Exit

DMI Event Logging

Table 11 lists the selections available on the Advanced menu. This menu configures advanced

features available through the chipset.

Table 11. Advanced Menu

I/O Device Configuration Select to display submenu

On Board Device Select to display submenu

PCI Configuration

Server Menu

Select to display submenu

Select to display submenu

Console Redirection

DMI Event Logging

Select to display submenu

Select to display submenu

Hardware Monitor

Installed O/S

Select to display submenu

Win2000/.NET

/ XP (default)

NT4

NetWare

Other

Configures the I/O ports.

Configures the onboard RAID, network, and USB controllers.

Configures PCI or RAID devices.

Sets options for server features.

Provides additional options to configure the console.

Displays the event logs.

Displays voltages, temperatures, and fan speeds for the system.

Specifies the operating system installed on your system that you will use most often. An incorrect setting can cause some operating systems to behave erratically.

Note: If you select NT4, an additional submenu item, NT4

Installation Workaround, will appear. It is disabled by default. To install Windows NT

*

4.0, you need to change the NT4 Installation Workaround option to Enabled.

Disable it to install pertinent service packs. continued

Server Board Installation 29

Table 11. Advanced Menu (continued)

Boot-time Diagnostic

Screen

Reset Configuration Data

PS/2 Mouse

Summary Screen

Disabled

Large Disk Access Mode

Other

DOS (default)

Enabled

(default)

No (default)

Yes

Disabled

Enabled

Auto Detect

(default)

Enables or disables the boot-time diagnostic screen.

Disabled will display the splash screen over the diagnostic screen. This splash screen can be changed to show an

OEM-based logo.

Specifies if the extended server configuration data will be reset during the next boot.

Yes clears the extended server configuration data during the next boot. The system automatically resets this field to

No during the next boot.

UNIX

*

, NetWare

*

, and other operating systems require this option be set to Other. If you install an operating system and the hard drive fails to install, change this setting and try again. Different operating systems require different representations of drive geometries.

Configures the PS/2 mouse.

Disabled prevents any installed PS/2 mouse from functioning but frees up IRQ 12.

Enabled forces the PS/2 mouse port to be enabled even if a mouse is not present.

Auto Detect will enable the PS/2 mouse only if one is present.

Enables or disables the boot-time hardware/BIOS summary screen.

Legacy USB Support

Hyper-Threading

QuickBoot Mode

Disabled

Enabled

(default)

Disabled

Enabled

(default)

Disabled

Enabled

(default)

Disabled

(default)

Enabled

Enables support for legacy USB. It may be necessary to set this option to Disable to install NetWare 6.0 SP1.

Allows Intel Xeon processors to run in hyperthreading mode. Enabling this setting will improve throughput significantly on certain applications.

Allows the system to skip the memory test while booting.

This decreases the time needed to boot the system.

30 Intel Server Board SE7501CW2 Product Guide

I/O Device Configuration Submenu

To access this submenu, select Advanced on the menu bar at the top of the screen and then I/O

Device Configuration.

Main

Advanced

Security Power

I/O Device Configuration

Boot System Exit

On Board Device

DMI Event Logging

Table 12 lists the options available through the I/O Device Configuration submenu. This submenu

configures the I/O ports on the board.

Table 12. I/O Device Configuration Submenu

Serial port A

Base I/O Address

(This feature is present only when Serial Port A is set to Enabled)

Disabled

Enabled

(default)

3F8 (default)

2F8

3E8

2E8

IRQ3

IRQ4 (default)

Interrupt

(This feature is present only when Serial Port A is set to Enabled)

Serial port B

Base I/O Address

(This feature is present only when Serial Port B is set to Enabled)

Interrupt

(This feature is present only when Serial Port B is set to Enabled)

Parallel port

Disabled

Enabled

(default)

3F8

2F8 (default)

3E8

2E8

IRQ3 (default)

IRQ4

Disabled

Enabled

(default)

Enables or disables serial port A.

Two devices cannot share the same IRQ. Choosing

Disabled makes serial port A unusable.

Sets the base I/O address for serial port A.

Sets the interrupt for serial port A.

Enables or disables onboard serial port B.

Two devices cannot share the same IRQ. Choosing

Disabled makes serial port B unusable.

Sets the base I/O address for serial port B.

Sets the interrupt for serial port B.

Enables or disables the onboard parallel port.

Two devices cannot share the same IRQ. Also, choosing

Disabled makes the parallel port unusable. continued

Server Board Installation 31

Table 12. I/O Device Configuration Submenu (continued)

Mode

(This feature is present only when Parallel Port is set to Enabled)

Output only

Bi-directional

EPP

ECP (default)

Sets the mode for the parallel port.

Output only is the standard printer connection mode.

Bi-directional is the standard bidirectional mode.

EPP is Enhanced Parallel Port mode, a high-speed bidirectional mode.

Selection based on what EPP version the printer supports. Only choose a mode that the parallel port device (such as a printer) supports. Check the parallel port device documentation for this information. If this information cannot be located, use the default setting.

ECP is Extended Capabilities Port mode, a high-speed bidirectional mode.

Sets the base I/O address for the parallel port. Base I/O Address

(This feature is present only when Parallel Port is set to Enabled)

Interrupt

(This feature is present only when Parallel Port is set to Enabled)

DMA channel

(This feature is present only when Parallel Port is set to Enabled)

Floppy disk controller

378 (default)

278

3BC

IRQ5

IRQ7 (default)

DMA 1

DMA 3

(default)

Disabled

Enabled

(default)

Sets the interrupt for the parallel port.

Sets the DMA channel for the parallel port.

Enables or disables the onboard diskette controller.

32 Intel Server Board SE7501CW2 Product Guide

On Board Device Submenu

To access this submenu, select Advanced on the menu bar at the top of the screen and then On

Board Device.

Main

Advanced

Security Power

I/O Device Configuration

Boot System Exit

On Board Device

DMI Event Logging

Table 13 lists the options available through the On Board Device submenu. This submenu

configures the RAID, network, and USB controllers on the board.

Table 13. On Board Device Submenu

Onboard NIC 1

Onboard NIC 2

Onboard USB

Disabled

Enabled

(default)

Disabled

Enabled

(default)

Disabled

Enabled

(default)

Enables the onboard PCI Intel 82550PM Controller (Device 4).

Enables the onboard PCI Intel 82540EM Controller (Device 5).

Enables the ICH3-S USB controllers.

Server Board Installation 33

PCI Configuration Submenu

To access this submenu, select Advanced on the menu bar at the top of the screen and then PCI

Configuration.

Main

Advanced

Security Power

I/O Device Configuration

Boot System Exit

On Board Device

PCI Configuration

Slot 1 PCI-X 133

Slot 2 PCI-X 100

Slot 3 PIC-X 100

Slot 4 PCI 32/33

Slot 5 PCI 32/33

DMI Event Logging

Table 14 lists the options available through the PCI Configuration submenu. This submenu

configures the option ROM area for onboard RAID and PCI devices.

Table 14. PCI Configuration Submenu

Onboard NICs Set items for configuring the onboard NICs

Slot 1 PCI-X 133

Slot 2 PCI-X 100

Slot 3 PCI-X 100

Slot 4 PCI 32/33

Slot 5 PCI 32/33

Select to display submenu

Select to display submenu

Select to display submenu

Select to display submenu

Select to display submenu

Select to display submenu

Configures the specific PCI device expansion ROM.

Configures the specific PCI device expansion ROM.

Configures the specific PCI device expansion ROM.

Configures the specific PCI device expansion ROM.

Configures the specific PCI device expansion ROM.

34 Intel Server Board SE7501CW2 Product Guide

The table below lists the options available when the Onboard NICs option is selected. This submenu appears for each of the PCI slot options available on the Advanced PCI Configuration

submenu (see Table 14). For brevity, only one example is shown.

Table 15. Onboard NICs Submenu

Onboard NIC1 PXE

Onboard NIC2 PXE

Disabled

(default)

Enabled

Disabled

(default)

Enabled

Enable support for the onboard Intel 82550PM NIC PXE

Note: Once PXE boot is enabled, it will not be selectable in the boot order until after the system is restarted.

Enable support for the onboard Intel 82540EM NIC PXE

Note: Once PXE boot is enabled, it will not be selectable in the boot order until after the system is restarted.

The following table lists the options available on the Option ROM Scan submenu. This submenu appears for each of the PCI slot options available on the PCI Configuration submenu (see

Table 14). For brevity, only one example is shown.

Table 16. Option ROM Scan Submenu

Option ROM Scan

Enabled

(default)

Disabled

Initializes the device expansion ROM.

Server Board Installation 35

Server Menu Submenu

To access this submenu, select Advanced on the menu bar at the top of the screen and then

Server Menu.

Main

Advanced

Security Power

I/O Device Configuration

Boot System Exit

On Board Device

Server Menu

DMI Event Logging

Table 17 lists the options available through the Server Menu submenu. This submenu allows you

to set options for server features.

Table 17. Server Menu Submenu

NMI on PERR

NMI on SERR

Disabled

(default)

Enabled

Disabled

Enabled

(default)

Enables or disables nonmaskable interrupts (NMI) on parity errors on the PCI bus (PERRs).

Enables or disables

NMI on system errors on the PCI bus

(SERRs).

36 Intel Server Board SE7501CW2 Product Guide

Console Redirection Submenu

To access this submenu, select Advanced on the menu bar at the top of the screen and then Console

Redirection.

Main

Advanced

Security Power

I/O Device Configuration

Boot System Exit

On Board Device

Console Redirection

DMI Event Logging

Table 18 lists the options available through the Console Redirection submenu. This submenu

provides additional options to configure the console.

Table 18. Console Redirection Submenu

COM Port Address

Baud Rate

Console Type

Flow Control

Console Connection

Continue C.R. after

POST

Disabled

(default)

O n-board

COM A

On-board

COM B

300

1200

2400

9600

19.2K

(default)

38.4K

57.6K

115.2K

PC ANSI

(default)

VT100

None

XON/XOFF

CTS/RTS

(default)

Direct

(default)

Via modem

Off

(default)

On

When enabled, console redirection uses the I/O port specified.

All keyboard/mouse and video will be directed to this port. This setting is for use only under DOS in text mode.

When console redirection is enabled, specifies the baud rate to be used.

Enables the specified console type.

PC ANSI is color, 7-bit data.

VT100 is monochrome, 7-bit data.

None disallows flow control.

XON/XOFF is software-based asynchronous flow control.

CTS/RTS is hardware-based flow control.

When EMP is sharing the COM port as console redirection, the flow control must be set to CTS/RTS.

Indicates whether the console is connected directly to the system or whether a modem is used.

Enables console redirection (C.R.) after the operating system has been loaded. If on, the system needs 4 KB of EBDA

(Extended BIOS Data Area) memory space.

Server Board Installation 37

DMI Event Logging Submenu

To access this submenu, select Advanced on the menu bar at the top of the screen and then Event

Logging.

Main

Advanced

Security Power

I/O Device Configuration

Boot System Exit

On Board Device

DMI Event Logging

Table 19 lists the options available through the DMI Event Logging submenu. This submenu

allows you to view the event logs.

Table 19. DMI Event Logging Submenu

Event log validity

Event log capacity

View DMI event log

No options

No options

<Enter>

Indicates if the contents of the event log are valid.

Indicates if there is space available in the event log.

Select <Enter> to display the current event log. Only Single Bit

Error (SBE) and Multi Bit Error (MBE) events on the memory bus are supported. No Winbond 83627HF Super I/0 information is available.

Enables logging of events. Event Logging

ECC Event Logging

Disabled

Enabled

(default)

Disabled

Enabled

(default)

Clear all DMI event logs

No

(default)

Yes

Enables logging of ECC events.

Clears the event log after booting.

Must be set to Yes if the Event Log Validity option is invalid.

38 Intel Server Board SE7501CW2 Product Guide

Hardware Monitor Submenu

To access this submenu, select Advanced on the menu bar at the top of the screen and then

Hardware Monitor.

Main

Advanced

Security Power

I/O Device Configuration

Boot System Exit

On Board Device

DMI Event Logging

Hardware Monitor

Table 20 lists the settings displayed in the Hardware Monitor submenu. This submenu displays

temperature, voltages, and fan speeds for the onboard Super I/O Winbond ASIC (the values listed below are for reference only). Use the up and down arrow keys to scroll through the readings.

Table 20. Hardware Monitor Submenu

Hardware Monitor IO index/data

VCC_CPU_A

+1_8V_A

+3_3V_A

AVCC

AUX3V

+12ENG

+2_5V_A

AUX5V

VBAT

Ambiance

CPU1

CPU2

System FAN 1 speed

System FAN 2 speed

System FAN 3 speed

System FAN 4 speed

CPU FAN 1 speed

CPU FAN 2 speed

No options

No options

No options

No options

No options

No options

No options

No options

No options

No options

No options

No options

No options

No options

No options

No options

No options

No options

No options

Value fluxuates. Example: 0295h

Value fluxuates. Example: 1.45 V

Value fluxuates. Example: 1.79 V

Value fluxuates. Example: 3.24 V

Value fluxuates. Example: 5.02 V

Value fluxuates. Example: 3.29 V

Value fluxuates. Example: 12.01 V

Value fluxuates. Example: 2.49 V

Value fluxuates. Example: 4.94 V

Value fluxuates. Example: 2.92 V

Value fluxuates. Example: 35 °C /95 °F

Value fluxuates. Example: 51 °C/123 °F

Value fluxuates. Example: 34 °C/93 °F

Value fluxuates. Example: 5260 RPM

Value fluxuates. Example: 4560 RPM

Value fluxuates. Example: 4560 RPM

Value fluxuates. Example: 4560 RPM

Value fluxuates. Example: 4560 RPM

Value fluxuates. Example: 4560 RPM

Server Board Installation 39

Security Menu

To access this menu, select Security on the menu bar at the top of the screen.

Main Advanced

Security

Power Boot System Exit

Table 21 lists the options available on the Security menu. Enabling the Supervisor Password field

requires a password for entering Setup. The passwords are not case-sensitive.

Table 21. Security Menu

If no password entered previously:

Set User

Password

Set Supervisor

Password

Password on boot

Diskette access

<Enter>

<Enter>

Disabled

Enabled

(default)

User

(default)

Supervisor

The user password controls access to the system at boot. When the <Enter> key is pressed, you are prompted for a password; press the ESC key to abort.

The supervisor password must be set if a user password is to be used.

NOTE: Entering Setup with a supervisor password provides full access to all BIOS Setup utility menus.

The supervisor password controls access to the BIOS Setup utility.

When the <Enter> key is pressed, you are prompted for a password; press the ESC key to abort.

This password can be set only if a supervisor password is entered.

When the user has entered his or her name but the supervisor is not logged in, only the following information is accessible:

Supervisor password is set to Enabled.

User password is set to Enabled.

Set user password [press enter] to enter a user password.

Password on boot is set to Enabled/Disabled (whichever is in effect). This option is not allowed to change.

Requires password entry before boot. System will remain in secure mode until password is entered. If a user or supervisor password is not entered, the operating system cannot be accessed.

Controls who can access diskette drives.

Supervisor limits access to the diskette drive to the supervisor, who must enter a password.

User allows access to the diskette drive by entering either the supervisor or the user password.

Whatever setting is chosen, it becomes functional only if both a supervisor password and a user password have been set (if the

User setting is chosen).

40 Intel Server Board SE7501CW2 Product Guide

Power Menu

To access this menu, select Power on the menu bar at the top of the screen.

Main Advanced Security

Power

Boot System Exit

Table 22 lists the options available on the Power menu. This menu is designed to disable ACPI

automatic reboot in the S0 or S4 states. If these submenus are enabled and AC power is lost, the server power and its operating system will remain off.

Table 22. Power Menu

Power Loss Control

Power Button

Stay Off

Last State

(default)

Disable

Enable

(default)

Specifies the power level the system returns to after AC power is lost.

Stay Off leaves the server power disabled and ACPI does not function to reboot the server in the event of a power failure.

Last State reboots the system according to ACPI standards.

Enables or disables the power button functionality.

Server Board Installation 41

Boot Menu

To access this menu, select Boot on the menu bar at the top of the screen.

Main Advanced Security Power

Boot

System Exit

Table 23 lists the options available on the Boot menu. This menu allows you to set the boot priority

of devices installed in the system. Use the following key combinations to navigate between or view the devices and change the boot priority:

<Enter> expands or collapses devices that have a “+” or “-” in front of them.

<Ctrl+Enter> expands all devices.

<Shift+1> enables or disables devices. Disabled devices appear with a “!” in front of them.

<+> and <-> moves the device up or down in the list.

<n> may move the removable device between the hard drive or removable disk.

<d> removes a device that is not installed.

Table 23. Boot Menu

Boot Priority

1 st

Boot Device

2 nd

Boot Device

3 rd

Boot Device

4 th

Boot Device

Device

Removable

Devices

Hard Drive

CD-ROM

Drive

Network

Boot

Description

Specifies the boot sequence according to the device type. The computer will attempt to boot from up to four devices as specified here. Only one of the devices can be an IDE hard disk drive.

The default settings for the first through fourth boot devices are, respectively:

Removable Devices:

Attempts to boot from the diskette drive or a removable device, such as the floppy.

Hard Drive:

Attempts to boot from a hard drive device.

CD-ROM Drive:

Attempts to boot from a CD-ROM drive containing bootable media. This entry appears if there is a bootable CD-ROM that is in a BIOS Boot Specification

(BBS)–compliant SCSI CD-ROM.

Network Boot: If the network card ROM contains the string

$PnP, it uses the correct BBS and the device will appear under the Boot menu as an independent device. Otherwise, it will appear under the Boot/Network Boot submenu.

42 Intel Server Board SE7501CW2 Product Guide

System Menu

To access this menu, select System on the menu bar at the top of the screen.

Main Advanced Security Power Boot

System

Exit

Table 24 lists the options available on the System menu. This menu displays information on

vendor, processor, memory, peripherals, and BIOS.

Table 24. System Menu

Machine Vendor

<Enter>

CPU

Memory

<Enter>

<Enter>

Provides basic information on the machine vendor:

Manufacturer: Intel Corporation

Product: SE7501CW2

Version: 1.00

Serial Number: 12345678

Provides basic information on the processor

Boot Strap Processor:

Installed Speed: 2.4 GHz (for example)

Socket Name: BSP

Manufacturer: GenuineIntel

Version: Intel(R) XEON(TM)

CPUID: 0F27

L2 Cache: 512 KB

Application Processor:

Installed Speed: 1.8 GHZ (for example)

Socket Name: AP

Manufacturer: GenuineIntel

Version: Intel(R) XEON(TM)

CPUID: 0F27

L2 Cache: 512 KB

Provides basic information on the memory:

System Memory: 640 KB

Extended Memory: 255 MB

Shadow RAM: 384 KB

Cache RAM: 512 KB

Installed Size—DIMM 1A, 1B, 2A, and 2B: DIMM size in MB continued

Server Board Installation 43

Table 24. System Menu (continued)

Peripherals

<Enter>

Provides the port connectors for onboard designators. None of these can be modified in user mode

Port

Connector

On Board

Designator

Port

Connector

On Board

Designator

J52 & J28 Serial A and B

J47 Parallel

J12 Floppy

BIOS

<Enter> mouse

J7

J8

Primary IDE

Secondary IDE

J48 & J45

J10 & J50

ROM SIZE: 1024 KB

Vendor: Phoenix Technologies LTD

Version: 1.14

Release Date: 1/10/2003 – creation date

NIC1 and NIC2

USB

Exit Menu

To access this menu, select Exit on the menu bar at the top of the screen.

Main Advanced Security Power Boot System

Exit

Table 25 lists the options available in the Exit menu. Select an option using the up or down arrow

keys; then press <Enter> to execute the option. Pressing <Esc> does not exit this menu. You must select one of the items from the menu or menu bar to exit.

Table 25. Exit Menu

Choices Description

Exit Saving Changes

Exit Discarding Changes

Load Setup Defaults

Discard Changes

Save Changes

Load Custom Default

Save Custom Default

Exits after writing all modified Setup item values to CMOS.

Exits leaving CMOS unmodified. User is prompted if any of the setup fields were modified.

Loads default values for all Setup items.

Reads previous values of all Setup items from CMOS.

Writes all Setup item values to CMOS.

Loads custom default values for all setup items.

Saves all Setup item values to NVRAM as a custom default.

44 Intel Server Board SE7501CW2 Product Guide

Upgrading the BIOS

Preparing for the Upgrade

Before you upgrade the BIOS, prepare for the upgrade by recording the current BIOS settings, obtaining the upgrade utility, and making a copy of the current BIOS.

Recording the Current BIOS Settings

1. Boot the computer and press <F2> when you see the message:

Press <F2> Key if you want to run SETUP

2. Write down the current settings in the BIOS Setup program.

NOTE

Do not skip step 2. You will need these settings to configure your computer at the end of the procedure.

Obtaining the Upgrade Utility

You can upgrade to a new version of the BIOS using the new BIOS files and the BIOS upgrade utility, PHLASH.EXE. You can obtain the BIOS upgrade file and the PHLASH.EXE utility through your computer supplier or from the Intel Customer Support Web site. On the Customer

Support Website, click on “Download Software and Drivers” at: http://support.intel.com/support/motherboards/server/SE7501CW2

NOTE

Please review the instructions distributed with the upgrade utility before attempting a BIOS upgrade. Review also any release notes in the release notes file that accompanies the new version of the BIOS. The release notes may contain critical information regarding jumper settings, specific fixes, or other information to complete the upgrade.

This upgrade utility allows you to upgrade the BIOS in flash memory. The code and data in the upgrade file include the following:

On-board BIOS, ATA-100 RAID BIOS, and PXE option ROMs for the devices that are embedded on the system board

The Setup Utility

The System BIOS

The following steps explain how to upgrade the BIOS. In the unlikely event that a BIOS error

occurs during the BIOS update process, see Recovering the BIOS on page 82 for instructions on performing a BIOS recovery.

Server Board Installation 45

Creating a Bootable Diskette

Use a DOS system to create the diskette as follows:

1. Insert a diskette in diskette drive A.

2. At the C:\ prompt, for an unformatted diskette, type: format a:/s or, for a diskette that is already formatted, type: sys a:

Creating the BIOS Upgrade Diskette

The BIOS upgrade file is a compressed self-extracting archive that contains the files you need to upgrade the BIOS.

1. Download the BIOS image file to a temporary folder on your hard drive. The image is available from

http://support.intel.com/support/motherboards/server/SE7501CW2

2. Insert the bootable diskette you created in the steps above into the diskette drive.

3. Type to extract the update files from the image file and place them onto the bootable diskette. “[ filename

]” is the name of the file that you downloaded.

Upgrading the BIOS

1. Place the bootable diskette containing the BIOS update files into the diskette drive of your system. Boot the system with the diskette in the drive.

2. A menu will appear with two options. Use option 1 to automatically update the system BIOS.

Use option 2 to manually update the system BIOS and the User Binary.

3. If you selected option 1, to automatically update the system BIOS:

The system will execute the Phlash update utility to update the BIOS. When the update is complete, the utility will display a green box with a message that says “Completed

Successfully.” The system will then reboot.

4. If you selected option 2, to manually update the BIOS or to update the flash memory, you can either select “Update Flash Memory From a File” or “Update System BIOS”:

Update Flash Memory From a File: When prompted for a file name, type BIOS.wph and press Enter.

Update System BIOS: The system will warn you that the BIOS will be updated. Verify the

BIOS version is correct and press Enter to continue. When the update is complete, the utility will display a green box with a message that says “Completed Successfully.” The system will then reboot.

5. Wait while the BIOS files are updated. Do not power down the system during the BIOS

update process! The system will reset automatically when the BIOS update process is completed. Remove the diskette from the diskette drive.

6. Check to make sure the BIOS version displayed during POST is the new version as the system reboots.

7. Enter Setup by pressing the F2 key during boot. Once in Setup, press the F9 and <Enter> to set the parameters back to default values.

46 Intel Server Board SE7501CW2 Product Guide

8. Re-enter the values you wrote down at the beginning of this process. Press F10 and <Enter> to exit BIOS Setup and Save Changes.

9. If you do not set the CMOS values back to defaults using the F9 key, the system may function erratically.

NOTE

You may encounter a CMOS Checksum error or other problem after reboot.

If this happens, shut down the system and boot it again. CMOS checksum errors require that you enter Setup, check your settings, save your settings, and exit Setup.

Crisis Recovery Diskette

It is unlikely that anything will damage the BIOS; however, a recovery disk should be created to ensure a quick recovery should it happen. The following steps explain how to create the crisis recovery diskette. If an incident occurs that corrupts the BIOS, such as the interruption of the BIOS

update process, see Recovering the BIOS on page 82 for instructions on performing a BIOS

recovery.

You can obtain the Crisdisk.exe file needed to create the crisis disk from the Intel Customer

Support Web site:

http://support.intel.com/support/motherboards/server/SE7501CW2

Creating the Crisis Recovery Diskette

NOTE

The crisis recovery diskette must be created on a Windows 98, Windows 2000, or Windows XP system.

Use the following steps to create the diskette:

1. Create an empty folder at the Windows workstation.

2. Copy the Crisdisk.exe folder into the folder and type Crisdisk to extract the contents of the selfextracting file into the folder.

3. Insert an empty diskette into the A: drive.

4. While in the folder with the Crisdisk contents, type Wincris. You will be prompted by a screen that contains three options:

Create MINIDOS Crisis Disk: Installs the necessary recovery files onto the A: drive. Use this option if the diskette you are using is already formatted and bootable.

Create FULLDOS Crisis Disk: Makes the floppy disk in A: bootable and then installs the necessary recovery files. Use this option if the diskette you are using is blank, but not bootable.

Format the A: Drive Diskette: Formats the diskette in the A: drive. Use this option if the diskette is not blank. When this option is complete, you will then need to use the “Create

FULLDOS Crisis Disk option.”

When the crisis diskette has been created, you will be prompted with a message to remove the diskette. You will then be asked whether you want to create additional crisis diskettes.

Server Board Installation 47

48 Intel Server Board SE7501CW2 Product Guide

Changing the BIOS Language

You can use the BIOS upgrade utility to change the language the BIOS uses for messages and the

Setup program. Use a bootable diskette containing the Intel flash utility and language files.

1. Boot the computer with the bootable diskette in drive A. The BIOS upgrade utility screen appears.

2. Select Update Flash Memory From a File.

3. Select Language Set. Press <Enter>.

4. Select drive A and use the arrow keys to select the correct

.

lng file. Press <Enter>.

5. When the utility asks for confirmation that you want to flash the new language into memory, select Continue with Programming. Press <Enter>.

6. When the utility displays the message upgrade is complete, remove the diskette. Press

<Enter>.

7. The computer will reboot and the changes will take effect.

Hardware Monitoring

The Server Board SE7501CW2 has an integrated Winbond Heceta

*

836327HF chip that is responsible for hardware monitoring. Together, the Winbond Heceta chip and LANDesk

*

Client

Manager (LDCM) 6.3 software provide basic server hardware monitoring that alerts a system administrator if a hardware problem occurs.

The LANDesk Client Manager software is for use with Windows 2000 Server and Windows 2000

Advanced Server operating systems. Other operating systems supported by the Server Board

SE7501CW2 such as Windows XP, NetWare 6.0, or Red Hat

*

Linux

*

will not be monitored with

the LANDesk Client Manager software. Table 26 lists the monitored headers and sensors on the

server board.

Table 26. Monitored Headers and Sensors

Sensor Type

Item Description

Monitors processor voltage (one CPU power plane) Voltage Vcpu

1.8V

5V

AUX3V

ENG12V

Vbat

SB5V

Monitors +5 Vcc

Monitors +3.3 Standby Voltage

Monitors 12 V

Monitors battery voltage

Monitors +5 Standby Voltage continued

Server Board Installation 49

Table 27. Monitored Headers and Sensors (continued)

Fan Speed FanIO0 Controls the front system fan J1

FanIO1

FanIO2

Controls the front system fan 31

Controls the front system fan J58

TACH0

TACH1

TACH2

Monitors the rear system fan J29

Monitors the rear system fan J30

Monitors CPU1 fan J16

Temperature

TACH3

CPU1

CPU2

Ambient

Monitors CPU2 fan J14

Monitors primary processor temperature

Monitors secondary processor temperature

Monitors chassis ambient temperature

50 Intel Server Board SE7501CW2 Product Guide

3 Server Board Installations and Upgrades

Tools and Supplies Needed

Phillips

*

(cross head) screwdriver (#1 bit and #2 bit)

Needle nosed pliers

A ruler

Pen or pencil

Antistatic wrist strap and conductive foam pad (recommended)

Before You Begin

Emissions Disclaimer

To ensure EMC compliance with your local regional rules and regulations, the final configuration of your end system product may require additional EMC compliance testing. For more information please contact your local Intel Representative.

See “Regulatory and Integration Information” on page 91 for product Safety and EMC regulatory

compliance information. This is an FCC Class A device. Integration of it into a Class B chassis does not result in a Class B device.

Safety Cautions

Read all caution and safety statements in this document before performing any of the instructions.

See also Intel Server Boards and Server Chassis Safety Information on the Resource CD and/or at http:\\support.intel.com

.

CAUTIONS

System power on/off:

The power button DOES NOT turn off the system

AC power. To remove power from system, you must unplug the AC power cord from the wall outlet. Make sure the AC power cord is unplugged before you open the chassis, add, or remove any components.

Hazardous conditions, devices & cables

: Hazardous electrical conditions may be present on power, telephone, and communication cables.

Turn off the server and disconnect the power cord, telecommunications systems, networks, and modems attached to the server before opening it.

Otherwise, personal injury or equipment damage can result.

Server Board Installation 51

Electrostatic discharge (ESD) & ESD protection:

ESD can damage disk drives, boards, and other parts. We recommend that you perform all procedures in this chapter only at an ESD workstation. If one is not available, provide some ESD protection by wearing an antistatic wrist strap attached to chassis ground

 any unpainted metal surface

 on your server when handling parts.

ESD and handling boards:

Always handle boards carefully. They can be extremely sensitive to ESD. Hold boards only by their edges. After removing a board from its protective wrapper or from the server, place the board component side up on a grounded, static free surface. Use a conductive foam pad if available but not the board wrapper. Do not slide board over any surface.

Installing or removing jumpers:

A jumper is a small plastic encased conductor that slips over two jumper pins. Some jumpers have a small tab on top that you can grip with your fingertips or with a pair of fine needle nosed pliers. If your jumpers do not have such a tab, take care when using needle nosed pliers to remove or install a jumper; grip the narrow sides of the jumper with the pliers, never the wide sides. Gripping the wide sides can damage the contacts inside the jumper, causing intermittent problems with the function controlled by that jumper. Take care to grip with, but not squeeze, the pliers or other tool you use to remove a jumper, or you may bend or break the stake pins on the board.

Safety and Regulatory Compliance

See “Regulatory and Integration Information” on page 91 for product Safety and EMC regulatory

compliance information.

Intended uses: This product was evaluated for use in servers that will be installed in offices, computer rooms, and similar locations. Other uses require further evaluation.

EMC testing: Before computer integration, make sure that the chassis, power supply, and other modules have passed EMC testing using a server board with a microprocessor from the same family (or higher) and operating at the same (or higher) speed as the microprocessor used on this server board.

Server board diagram label provided: Place the label inside the chassis in an easy-to-see location, preferably oriented similarly to the server board.

52 Intel Server Board SE7501CW2 Product Guide

Minimum Hardware Requirements

To avoid integration difficulties and possible board damage, your system must meet the following minimum requirements. For a list of qualified memory and chassis components see:

http://support.intel.com/support/motherboards/server/SE7501CW2

Processor

A minimum of one 1.8 GHz Intel Xeon processor with 512KB cache support is required. For a complete list of supported processors, see:

http://support.intel.com/support/motherboards/server/SE7501CW2

Memory

A minimum of one 128 MB Registered, ECC, DDR200- or DDR266- compliant, 184-pin DIMMs.

3

Power Supply

A minimum of 450W is required. Your supply must provide a minimum of 1.2 A of 5 V standby current or the board will not boot.

Installation Notes

Installation Process Quick Reference

Step

Remove the access cover

Where the information is located

Your chassis manual

Install the I/O shield

Install memory

Install the standoffs

Install the rubber bumpers

Install the server board

Install the primary processor

Install the secondary processor

(optional)

Connect cables to the server board

This guide

This guide

This guide

This guide

This guide

This guide

This guide

This guide and your chassis manual

3

DDR200-compliant ECC DIMMs can be used only if 400 MHz processors are installed.

Server Board Installation 53

Installation Procedures

Installing the I/O Gasket and Shield

NOTE

An ATX 2.03-compliant I/O shield is provided with the server board. The shield is required by Electromagnetic Interference (EMI) regulations to minimize EMI. If the shield does not fit the chassis, obtain a properly sized shield from the chassis supplier.

The shield fits the rectangular opening in the back of a chassis. The shield has cutouts that match the I/O ports. Install the shield from inside the chassis.

Attaching the Gasket to the I/O Shield

1. Remove the two backing strips from the gasket.

2. Press the gasket onto the inside face of the I/O shield as shown.

OM14074

Figure 4. Attaching the Gasket to the I/O Shield

54 Intel Server Board SE7501CW2 Product Guide

Attaching the Label to the I/O Shield

1. Remove the backing from the label included with your server board.

2. Press the label onto the outside face of the I/O shield. See Figure 5, A.

USB

1

2

3

MO

US

KYB

D

E

PA

RA

LL

EL

10

NE

T

B

A

OM14360

Figure 5. Attaching the Label to the I/O Shield

Installing the I/O Shield

1. Position one edge so that the dotted groove is outside the chassis wall, and the lip of the shield rests on the inner chassis wall.

2. Hold the shield in place, and push it into the opening until it is seated. Make sure the I/O shield snaps into place all the way around.

1

2

Figure 6. Installing the I/O Shield

OM14427

Server Board Installation 55

Installing Chassis Standoffs

Standoffs are included with your chassis. For the Intel

®

Server Chassis SC5200 and the

Intel

®

Server Chassis SC5250-E, the locations where standoffs need to be installed are shown below.

If you are using a non-Intel chassis, you must rearrange the standoffs so they match the holes in the server board. Failure to properly rearrange the metal standoffs may cause the server board to malfunction and may permanently damage it. If your chassis does not include a hole for a particular standoff, install the adhesive-backed standoff that is included with your server board.

Your chassis may be different from the illustrations below.

Intel

®

Server Chassis SC5200

The Server Chassis SC5200 comes with standoffs pre-installed in positions 1, 4, 6, 20, 23, and 26.

Install standoffs in positions (7, 18, 19, P, and S).

4

6

1

7

P

P

P

P

18

P

P

P

20

P

23

S

19

26

TP00267

Figure 7. Installing Chassis Standoffs in the SC5200

56 Intel Server Board SE7501CW2 Product Guide

Intel

®

Server Chassis SC5250-E

The Server Chassis SC5250-E comes with standoffs pre-installed in positions K, F, A, N, I, and D.

Install standoffs in positions L, H, C, E, the four positions marked P1, and the four positions marked P2).

F

A

K

L

P1

P1

P2

P2

H

P1

N

P1

P2

P2

I

E

C

D

TP00101

Figure 8. Installing Chassis Standoffs in the SC5250-E

Server Board Installation 57

Installing the Server Board

Placing the Server Board into the Chassis

When placing the board into the Server Chassis SC5200, insert the rear I/O connector end first, carefully positioning the board’s I/O connectors into the openings in the I/O shield on the back of the chassis.

TP00103

Figure 9. Placing the Server Board in the SC5200 Chassis

When placing the board into the Server Chassis SC5250-E, you must first remove the hard drive cage. See the Intel

®

Server Chassis SC5250-E Quick Start User’s Guide or the Intel

®

Server

Chassis Product Guide for instructions.

After removing the hard drive cage, insert the front of the board first, then slide the board back so that the I/O connectors protrude through the I/O shield at the rear of the chassis.

58

TP00102

Figure 10. Placing the Server Board in the SC5250-E Chassis

Intel Server Board SE7501CW2 Product Guide

Attaching the Server Board to the Server Chassis SC5200

Mount the board to the chassis at the 10 locations shown by the figure below. Use screws from the bag labeled “C” that came with your chassis.

NOTE

The Server Chassis SC5200 (all versions) and the Server Chassis SC5250-E use different screws to attach the server board to t he chassis. Be sure to use the appropriate screw for your chassis. The Server Chassis SC5200 uses

screws from the bag labeled “C”. See Figure 11.

TP00265

Figure 11. Attaching the Server Board to Server Chassis SC5200

Attaching the Server Board to the Server Chassis SC5250-E

1. Press down firmly over the two snap-top standoffs that are indicated by the arrows in Figure 13.

TP00265

Figure 12. Engaging the Server Chassis SC5250-E Snap-top Standoffs

2. Mount the board to the chassis at the 8 locations shown by the figure below. Use screws from the bag labeled “A” that came with your chassis.

Server Board Installation 59

NOTE

The Server Chassis SC5200 (all versions) and the Server Chassis SC5250-E use different screws to attach the server board to the chassis. Be sure to use the appropriate screw for your chassis. The Server Chassis SC5250-E uses screws from the bag labeled “A”. See the diagram below.

TP00266

Figure 13. Attaching the Server Board to Server Chassis SC5250-E

60 Intel Server Board SE7501CW2 Product Guide

Installing or Replacing Memory

The server board supports only DDR200- and DDR266-compliant DIMMs. Install from 128 MB to

8 GB of memory, using up to four DIMMs.

4

DIMM 1A and DIMM 1B constitute Bank 1.

DIMM 2A and DIMM 2B constitute Bank 2.

Memory must be installed according to the following rules:

DIMM 1A must be populated first. This DIMM the closest to the edge of the board.

When only a single DIMM is to be used, that DIMM must be inserted into slot 1A.

When Bank 2 is used, both slots must be populated and Bank 1 must be fully populated with two DIMMs.

No DIMM mixing is allowed within a bank. Between banks only the DIMM size may be different.

All DIMMs must be the same speed and architecture. For a list of supported memory, visit the Intel

Support Web site:

http://support.intel.com/support/motherboards/server/SE7501CW2

DIMM 1A

DIMM 1B

DIMM 2A

DIMM 2B

1

3 2

Figure 14. Installing Memory

3

1

TP00089

4

DDR200-compliant ECC DIMMs can be used only if 400 MHz processors are installed.

Server Board Installation 61

Installing or Replacing the Processor(s)

NOTES

Use the instructions provided below to install or replace a processor instead of using the instructions that came with the processor.

If you are installing only one processor, it must be installed in the labeled

CPU1. This socket is located closest to the corner of the server board.

If you are installing a second processor, verify that the second processor is identical to the first processor, same voltage and speed. Do not mix processors of different types or frequencies.

CAUTIONS

Processor must be appropriate:

You may damage the server board if you install a processor that is inappropriate for your server. Make sure your server can handle a newer, faster processor (thermal and power considerations). For exact information about processor interchangeability, contact your customer service representative or visit the Intel Customer

Support website: http://support.intel.com/support/motherboards/server/SE7501CW2

ESD and handling processors:

Reduce the risk of electrostatic discharge (ESD) damage to the processor by doing the following: (1) Touch the metal chassis before touching the processor or server board. Keep part of your body in contact with the metal chassis to dissipate the static charge while handling the processor. (2) Avoid moving around unnecessarily.

If you are adding a second processor to your system, you must verify that the second processor is identical to the first processor, same voltage and speed.

Using non-identical processors could cause system failure.

Installing the Processor(s)

Use these instructions if you are installing a processor and the Processor Wind Tunnel (PWT) in the

Server Chassis SC5200 base or Base Redundant Power, in the Server Chassis SC5250-E, or in a reference chassis.

If you are replacing a processor for which the PWT has already been installed, follow the

instructions provided on page 68 titled, “Replacing a Processor.”

1. Observe the safety and ESD precautions at the beginning of this chapter and the additional precautions given here.

2. Remove power from your system by unplugging the AC power cord.

3. Remove the chassis cover (see your system or chassis documentation for instructions).

4. Lift the socket lever for the processor.

5. Align the pins of the processor with the socket, and insert the processor into the socket. Lower the socket lever completely.

62 Intel Server Board SE7501CW2 Product Guide

NOTE

Make sure the alignment triangle mark and the alignment triangle cutout

align correctly. See Figure 15.

A

B

OM15042

Figure 15. Opening Socket Lever and Attaching Processor

Server Board Installation 63

Installing the Retention Mechanism(s) and the Heat Sink(s)

1. Install the PWT retention mechanism over the top of the processor with the screws provided, as

shown in Figure 16.

NOTE

The Server Chassis SC5200 and the Server Chassis SC5250-E use different fasteners to connect the

PWT retention mechanism to the server board. The fasteners look nearly identical, but the Server

Chassis SC5250-E fasteners are slightly shorter.

When using the Server Chassis SC5200, use the fasteners provided with the boxed processor.

When using the Server Chassis SC5250-E, use the fasteners provided with the chassis.

OM15037

Figure 16. Attaching Retention Mechanism

2. Apply thermal grease to the processor as shown in Figure 17.

64

OM15040

Figure 17. Applying Thermal Grease

Intel Server Board SE7501CW2 Product Guide

3. Align the heat sink over the processor and set it into place. If your heat sink has a flat end on it, the flat end must point toward the rear of the chassis.

4. Position the retention mechanism clips over the plastic tabs at the center of the retention mechanism. Note that the slot in the clip provides room for side-to-side motion. Push down on

the top of each retention clip while sliding it to over. (Figure 18, 1).

5. Engage each end of the retention mechanism clips over the plastic tabs at the sides of the

retention mechanism (Figure 18, 2).

6. Press downward on the ends of the retention mechanism clips to lock them into place over the

plastic tabs (Figure 18, 3 and 4).

NOTES

The 400 MHz Intel

®

Xeon™ processor and the 533 MHz Intel Xeon processor use different retention mechanism clips. Although the clips appear to be nearly identical, they vary slightly in size. Use only the clips that came with your processor.

For both the 400 MHz clips and the 533 MHz clips, make sure the center tab on the clip engages in the heat sink base.

A

C

B

C

E

D

1 3

2 4

TP00099

Figure 18. Attaching the Heat Sink and Retention Clip

Server Board Installation 65

Assembling the Processor Wind Tunnel

1. Hold the fan case at approximately 45 degrees and engage the clip at the top of the tunnel as

shown by Figure 19, 1. Rotate the fan case downward (Figure 19, 2) to insert the tabs at each side of the fan case into the matching slots on the wind tunnel (Figure 19, 3)

1

66

3

2

TP00041

Figure 19. Attaching the Fan Case to the Wind Tunnel

2. Insert the fan between the two large plastic tabs at each side of the wind tunnel assembly as

shown in Figure 20, 1. Note the following items in the figure:

To ensure that the airflow direction is correct, use caution to insert the fan so that the label

shows through the assembled unit (Figure 20, 2).

To ensure the fan power cables will reach the connection on the baseboard, note that when you are looking at the fan with the wind tunnel assembly behind it, the cable must extend

from the left side for CPU2 (Figure 20, 3) and from the right side for CPU1 (Figure 20, 4).

2

3

1

4

TP00042

Figure 20. Attaching the Heat Sink Fan to the PWT

Intel Server Board SE7501CW2 Product Guide

Attaching the Wind Tunnel Assembly to the Board

1. Attach the fan assembly to the retention mechanism that was installed over the top of the processors. Pull the tabs at the sides of the retention mechanism apart slightly.

See Figure 21, 1a.

2. Lower the fan assembly into the retention mechanism. The tabs on the fan assembly (Figure

21, 2a) will fit into the slots of the retention mechanism (Figure 21, 2b).

3. Pull out on the tabs located at the bottom of the fan assembly to snap them into place on the

OUTSIDE of the retention mechanism (Figure 21, 3a and 3b).

4. Attach CPU Fan 1 cable to the server board at location J16 and/or attach CPU Fan 2 cable at

location J14. (Figure 21, 4.)

1a

3a

2a

1b

1a

3b

2b

4

TP00100

Figure 21. Attaching the Top Assembly to the Retention Mechanism

NOTE

System airflow must be from front to back. Make sure the PWT is aligned so the fan is toward the front of the chassis and the airflow is toward the I/O shield. If two processors are installed, the fans must be side by side.

Server Board Installation 67

When assembled, the Processor Wind Tunnel will look similar to the figure below. The dashed lines over CPU2 indicate that this processor assembly is only required when configuring the server

with two processors. The direction of the airflow is indicated by the arrow at Figure 22, A.

CPU1

CPU2

A

Figure 22. Processor and Wind Tunnel Installed

TP00095

Replacing a Processor

1. Observe the safety and ESD precautions at the beginning of this chapter and the additional cautions given here.

2. Unplug the processor fan cable from the server board.

3. Detach the fan assembly from the PWT retention mechanism by unlatching the clips at the bottom of the fan assembly and then lifting up on the fan assembly.

4. Remove the metal retention mechanism clips from the bottom of the retention mechanism.

Unhook each side of each clip and disengage the center latch.

5. Remove the heat sink by slightly spreading the sides of the retention mechanism and lifting straight up on the heat sink.

6. Raise the socket lever on the processor socket.

7. Remove the processor from the socket.

8. Align the pins of the replacement processor with the socket, and insert the processor into the socket. Lower the socket lever completely.

NOTE

Make sure the alignment triangle mark and the alignment triangle cutout align correctly.

68 Intel Server Board SE7501CW2 Product Guide

1. Re-insert the heat sink over the top of the processor. Make sure to face the flat edge of the heat sink towards the rear of the chassis.

2. Reconnect the retention mechanism clips. See Figure 18.

3. Reattach the fan assembly to the retention mechanism. Pull the tabs at the sides of the retention

mechanism apart slightly. See Figure 21, 1a. Lower the fan assembly into the retention mechanism. The tabs on the fan assembly (Figure 21, 2a) will fit into the slots of the retention mechanism (Figure 21, 2b). Pull out on the tabs located at the bottom of the fan assembly to snap them into place on the retention mechanism (Figure 21, 3a and 3b).

4. Reattach the CPU fan

Replacing the Backup Battery

The lithium battery on the server board powers the RTC for up to 10 years in the absence of power.

When the battery starts to weaken, it loses voltage, and the server settings stored in CMOS RAM in the RTC (for example, the date and time) may be wrong. Contact your customer service representative or dealer for a list of approved devices.

WARNING

Danger of explosion if battery is incorrectly replaced. Replace only with the same or equivalent type recommended by the equipment manufacturer. Discard used batteries according to manufacturer’s instructions.

ADVARSEL!

Lithiumbatteri - Eksplosionsfare ved fejlagtig håndtering. Udskiftning må kun ske med batteri af samme fabrikat og type. Levér det brugte batteri tilbage til leverandøren.

ADVARSEL

Lithiumbatteri - Eksplosjonsfare. Ved utskifting benyttes kun batteri som anbefalt av apparatfabrikanten. Brukt batteri returneres apparatleverandøren.

VARNING

Explosionsfara vid felaktigt batteribyte. Använd samma batterityp eller en ekvivalent typ som rekommenderas av apparattillverkaren. Kassera använt batteri enligt fabrikantens instruktion.

VAROITUS

Paristo voi räjähtää, jos se on virheellisesti asennettu. Vaihda paristo ainoastaan laitevalmistajan suosittelemaan tyyppiin. Hävitä käytetty paristo valmistajan ohjeiden mukaisesti.

Server Board Installation 69

1. Observe the safety and ESD precautions at the beginning of this chapter and in the Intel Server

Boards and Server Chassis Safety Information on the Resource CD and/or at http:\\support.intel.com

.

2. Open the chassis.

3. Insert the tip of a small flat bladed screwdriver, or an equivalent, under the tab in the plastic retainer. Gently push down on the screwdriver to lift the battery.

4. Remove the battery from its socket.

TP00091

Figure 23. Replacing the Backup Battery

5. Dispose of the battery according to local ordinance.

6. Remove the new lithium battery from its package, and, being careful to observe the correct polarity, insert it in the battery socket.

7. Close the chassis.

8. Run Setup to restore the configuration settings to the RTC.

70 Intel Server Board SE7501CW2 Product Guide

Making Connections to the Server Board

The connections you make depend on the chassis you are installing the board into and the components you are installing. You may not need to make all of the connections shown by the figure below.

If you are installing your Server Board SE7501CW2 into the Server Chassis SC5250-E, install the hard drive cage before making your connections. This is because the hard drive cage contains one of the front system fans.

12 V

A

B

C

D

O

N

K

J

E

G

F

I

H

A

T

A

1

0

0

M

L

A. Main power connector

B. Auxiliary signal connector

C. +12 V CPU power connector

D. CPU1 fan header (top)

CPU2 fan header (bottom)

E. System fan 2 header (left)

System fan 1 header (right)

F. Front panel header black connector)

TP00090

J. System fan 5 header

K. Floppy drive connector

L. Front USB header

M. Serial B header

N. Chassis intrusion header

I. Primary IDE connector (bottom,

H. Secondary IDE connector (top, white connector)

P. System fan 3 header (top)

System fan 4 header (bottom)

Figure 24. Making Connections to the Server Board

Server Board Installation 71

Routing Cables

To ensure proper airflow within the chassis, follow the cable routing guidelines below.

IDE Cables

For the Server Chassis SC5200, IDE cables that connect to devices in the lower device bays should be routed around the EPAC as shown below.

1. Remove the top half of the EPAC.

2. Route cables as shown in Figure 25.

3. Replace the top half of the EPAC.

A

B

OM14196

Figure 25. Routing IDE Cables

For the Server Chassis SC5250-E, route the cables along the sides of the chassis, being careful to avoid blocking the airflow from the fans.

72 Intel Server Board SE7501CW2 Product Guide

Floppy Drive Cable

For the Server Chassis SC5200, route the floppy drive cable as shown in Figure 26, A.

A

OM14421

Figure 26. Routing the Floppy Drive Cable

For the Server Chassis SC5250-E, route the cables along the sides of the chassis, being careful to avoid blocking the airflow from the fans.

Server Board Installation 73

Finishing Up

WARNING

An electrical shock hazard exists if the chassis cover is not replaced before connecting the chassis to the main power.

1. Install the chassis cover according to the instructions for your chassis.

2. See your chassis documentation to complete the rack or pedestal installation.

3. Connect the keyboard, mouse, and video cables to the back panel.

4. Connect the power cable to the back panel and to an AC outlet.

A

C

E

D

B

G

F

B. USB 1, 2, and 3

C. Mouse

E. Serial port B

I

H

OM14424

F. Keyboard

G. Serial port A

H. Video

I. Network

NIC1 (10/100 Mb left)

NIC2 (1 Gb right)

Figure 27. Making Back Panel Connections

74 Intel Server Board SE7501CW2 Product Guide

This chapter helps you identify and solve problems that might occur while you are using the system.

Resetting the System

To do this:

Soft boot reset, which clears system memory and reloads the operating system.

Clear system memory, restart POST, and reload the operating system.

Cold boot reset. Turn the system power off and then on. This clears system memory, restarts POST, reloads the operating system, and halts power to all peripherals.

Press:

<Ctrl+Alt+Del>

Reset button

Power off/on

Initial System Startup

Problems that occur at initial system startup are usually caused by incorrect installation or configuration. Hardware failure is a less frequent cause.

Checklist

Is AC power available at the wall outlet?

Are the power supplies plugged in? Check the AC cable on the back of the chassis and at the

AC source.

Are all cables correctly connected and secured?

Are the processors fully seated in their sockets on the server board?

Are all standoffs in the proper location and not touching any through hole components, causing a potential short?

Are all add-in PCI boards fully seated in their slots on the server board?

Are all jumper settings on the server board correct?

Are all jumper and switch settings on add-in boards and peripheral devices correct? To check these settings, refer to the manufacturer’s documentation that comes with them. If applicable, ensure that there are no conflicts—for example, two add-in boards sharing the same interrupt.

Are all peripheral devices installed correctly?

If the system has a hard disk drive, is it properly formatted or configured?

Are all device drivers properly installed?

Are the configuration settings made in Setup correct?

Is the operating system properly loaded? Refer to the operating system documentation.

Did you press the system power on/off switch on the front panel to turn the server on (power on light should be lit)?

Is the system power cord properly connected to the system and plugged into a

NEMA 5-15R outlet for 100-120 V

or a NEMA 6-15R outlet for 200-240 V

?

Are all integrated components from the tested components lists? Check the tested memory, and chassis lists, as well as the supported hardware and operating system list on the Intel Customer

Support Web site.

75

Running New Application Software

Problems that occur when you run new application software are usually related to the software.

Faulty equipment is much less likely, especially if other software runs correctly.

Checklist

Does the system meet the minimum hardware requirements for the software? See the software documentation.

Is the software an authorized copy? Unauthorized copies often do not work.

If you are running the software from a diskette, is it a good copy?

If you are running the software from a CD-ROM disk, is the disk scratched or dirty?

If you are running the software from a hard disk drive, is the software correctly installed?

Were all necessary procedures followed and files installed?

Are the correct device drivers installed?

Is the software correctly configured for the system?

Are you using the software correctly?

If the problems persist, contact the software vendor’s customer service representative.

After the System Has Been Running Correctly

Problems that occur after the system hardware and software have been running correctly may indicate equipment failure. Many situations that are easy to correct, however, can also cause such problems.

Checklist

If you are running the software from a diskette, try a new copy of the software.

If you are running the software from a CD-ROM disk, try a different disk to see if the problem occurs on all disks.

Reinstall the software and try running it again. Make sure all necessary files are installed.

If the problems are intermittent, there may be a loose cable, dirt in the keyboard (if keyboard input is incorrect), a marginal power supply, or other random component failures.

If you suspect that a transient voltage spike, power outage, or brownout might have occurred, reload the software and try running it again. (Symptoms of voltage spikes include a flickering video display, unexpected system reboots, and the system not responding to user commands.)

NOTE

Random errors in data files: If you are getting random errors in your data files, they may be getting corrupted by voltage spikes on your power line. If you are experiencing any of the above symptoms that might indicate voltage spikes on the power line, you may want to install a surge suppressor between the power outlet and the system power cord.

76 Intel Server Board SE7501CW2 Product Guide

More Problem Solving Procedures

This section provides a more detailed approach to identifying a problem and locating its source.

Preparing the System for Diagnostic Testing

CAUTION

Turn off devices before disconnecting cables: Before disconnecting any peripheral cables from the system, turn off the system and any external peripheral devices. Failure to do so can cause permanent damage to the system and/or the peripheral devices.

1. Turn off the system and all external peripheral devices. Disconnect all of them from the system, except the keyboard and video monitor.

2. Make sure the system power cord is plugged into a properly grounded AC outlet.

3. Make sure your video display monitor and keyboard are correctly connected to the system.

Turn on the video monitor. Set its brightness and contrast controls to at least two thirds of their maximum ranges (see the documentation supplied with your video display monitor).

4. If the operating system normally loads from the hard disk drive, make sure there is no diskette in drive A. Otherwise, place a diskette containing the operating system files in drive A.

5. Turn on the system. If the power LED does not light, see “Power Light Does Not Light” on

page 79.

Monitoring POST

See Chapter 2.

Verifying Proper Operation of Key System Lights

As POST determines the system configuration, it tests for the presence of each mass storage device installed in the system. As each device is checked, its activity light should turn on briefly. Check for the following:

Does the diskette drive activity light turn on briefly? If not, see “Diskette Drive Activity Light

Does Not Light” on page 79.

If a second diskette drive is installed, does its activity light turn on briefly? If not, see “Diskette

Drive Activity Light Does Not Light” on page 79.

Confirming Loading of the Operating System

Once the system boots up, the operating system prompt appears on the screen. The prompt varies according to the operating system. If the operating system prompt does not appear, see “No

Characters Appear on the Screen” on page 78.

Solving Problems 77

Specific Problems and Corrective Actions

This section provides possible solutions for these specific problems:

Power light does not light.

No characters appear on screen.

Characters on the screen appear distorted or incorrect.

System cooling fans do not rotate.

Diskette drive activity light does not light.

Hard disk drive activity light does not light.

CD-ROM drive activity light does not light.

There are problems with application software.

The bootable CD-ROM is not detected.

Try the solutions below in the order given. If you cannot correct the problem, contact your service representative or authorized dealer for help.

Power Light Does Not Light

Check the following:

Is the system operating normally? If so, the power LED might be defective or the cable from the front panel to the server board might be loose.

Are there other problems with the system? If so, check the items listed under ‘System Cooling

Fans Do Not Rotate Properly.”

No Characters Appear on Screen

Check the following:

Is the keyboard functioning? Check to see that the “Num Lock” light is functioning.

Is the video monitor plugged in and turned on?

Are the brightness and contrast controls on the video monitor properly adjusted?

Are the video monitor switch settings correct?

Is the video monitor signal cable properly installed?

Is the onboard video controller enabled?

If you are using an add-in video controller board, do the following:

1. Verify that the video works using the onboard video controller.

2. Verify that the video controller board is fully seated in the server board connector.

3. Reboot the system for changes to take effect.

4. If there are still no characters on the screen after you reboot the system and POST emits a beep code, write down the beep code you hear. This information is useful for your service representative.

5. If you do not receive a beep code and characters do not appear, the video display monitor or video controller may have failed. Contact your service representative or authorized dealer for help.

78 Intel Server Board SE7501CW2 Product Guide

Characters Are Distorted or Incorrect

Check the following:

Are the brightness and contrast controls properly adjusted on the video monitor? See the manufacturer’s documentation.

Are the video monitor’s signal and power cables properly installed?

If the problem persists, the video monitor may be faulty or it may be the incorrect type. Contact your service representative or authorized dealer for help.

System Cooling Fans Do Not Rotate Properly

If the system cooling fans are not operating properly, system components could be damaged.

Check the following:

Is AC power available at the wall outlet?

Is the system power cord properly connected to the system and the wall outlet?

Did you press the power button?

Is the power on light lit?

Have any of the fan motors stopped (use the server management subsystem to check the fan status)?

Are the fan power connectors properly connected to the server board?

Is the cable from the front panel board connected to the server board?

Are the power supply cables properly connected to the server board?

Are there any shorted wires caused by pinched-cables or power connector plugs forced into power connector sockets the wrong way?

If the switches and connections are correct and AC power is available at the wall outlet, contact your service representative or authorized dealer for help.

Diskette Drive Activity Light Does Not Light

Check the following:

Are the diskette drive’s power and signal cables properly installed?

Are all relevant switches and jumpers on the diskette drive set correctly?

Is the diskette drive properly configured?

Is the diskette drive activity light always on? If so, the signal cable may be plugged in incorrectly.

If you are using the onboard diskette controller, use the BIOS setup to make sure that “Onboard

Floppy” is set to “Enabled.” If you are using an add-in diskette controller, make sure that

“Onboard Floppy” is set to “Disabled.”

If the problem persists, there may be a problem with the diskette drive, server board, or drive signal cable. Contact your service representative or authorized dealer for help.

Solving Problems 79

CD-ROM Drive Activity Light Does Not Light

Check the following:

Are the CD-ROM drive’s power and signal cables properly installed?

Are all relevant switches and jumpers on the drive set correctly?

Is the drive properly configured?

Cannot Connect to a Server

Make sure you are using the drivers that are shipped on the system Configuration Software CD for the onboard network controller.

Make sure the driver is loaded and the protocols are bound.

Make sure the network cable is securely attached to the connector at the system back panel. If the cable is attached but the problem persists, try a different cable.

Make sure the hub port is configured for the same duplex mode as the network controller.

Check with your LAN administrator about the correct networking software that needs to be installed.

If you are directly connecting two servers (no hub), you will need a crossover cable (see your hub documentation for more information on crossover cables).

Check the network controller LEDs that are visible through an opening at the system back panel.

Problems with Network

The server hangs when the drivers are loaded.

Change the PCI BIOS interrupts. Try the “PCI Installation Tips” below.

Diagnostics pass but the connection fails.

Make sure the network cable is securely attached.

Make sure you specify the correct frame type in your NET.CFG file.

The Activity LED does not light.

The network activity light is not connected to the Server Board SE7501CW2.

The controller stopped working when an add-in adapter was installed.

Make sure the cable is connected to the port from the onboard network controller.

Make sure your PCI BIOS is current. Try the “PCI Installation Tips” below.

Make sure the other adapter supports shared interrupts. Also, make sure your operating system supports shared interrupts.

Try reseating the add-in adapter.

80 Intel Server Board SE7501CW2 Product Guide

The add-in adapter stopped working without apparent cause.

Try reseating the adapter first; then try a different slot if necessary.

The network driver files may be corrupt or deleted. Delete and then reinstall the drivers.

Run the diagnostics.

PCI Installation Tips

Certain drivers may require interrupts that are not shared with other PCI drivers. For these drivers, it may be necessary to alter settings so that interrupts are not shared.

Problems with Application Software

If you have problems with application software, do the following:

Verify that the software is properly configured for the system. See the software installation and operation documentation for instructions on setting up and using the software.

Try a different copy of the software to see if the problem is with the copy you are using.

Make sure all cables are installed correctly.

Verify that the server board jumpers are set correctly. See Chapter 5.

If other software runs correctly on the system, contact your vendor about the failing software.

If the problem persists, contact the software vendor’s customer service representative for help.

Bootable CD-ROM Is Not Detected

Check the following:

Is the BIOS configured to allow the CD-ROM to be the first bootable device?

Solving Problems 81

Recovering the BIOS

In the rare event that the BIOS becomes damaged, a recovery process needs to be followed to return the system to service. Two methods are available to recover the BIOS: automatically with the crisis recovery diskette, and manually by moving a jumper on the system board. These methods are described below.

NOTE

BIOS recovery is the mode of last resort, used only when the main system

BIOS will not come up.

Recovering the BIOS with the Crisis Recovery Diskette

Automatically Recovering the BIOS

If a ROM checksum error occurs during POST, the system will automatically enter BIOS recovery mode. This is indicated by system beeping with one long beep followed by two short beeps. When you hear this beep pattern, use the following steps to initiate an automatic recovery:

1. Insert the Crisis Recovery Diskette into the A: diskette drive. (See the section titled Crisis

Recovery Diskette on page 47 for instructions on creating the diskette.)

2. A blue screen will be displayed and the recovery process will automatically run. The system will continue to beep throughout the recovery process. The recovery process is complete when the beeping stops.

3. Remove the diskette and power down the system.

4. Power the system up to restart it and confirm that the recovery was successful.

82 Intel Server Board SE7501CW2 Product Guide

Manually Recovering the BIOS

A BIOS recovery can also be manually initiated. This option would be used only when the BIOS is corrupt, but the ROM checksum error does not occur during POST. To manually initiate a BIOS recovery, use the following steps:

1. Power down and uplug the system from the AC power source.

2. Move the recovery jumper at J32 from the spare location at pins 9 and 10 to cover pins 3 and 4.

See the figure below.

Main Power

10

8

6

4

2

J32

9

7

5

3

1

TP00096

Figure 28. BIOS Recovery Jumper

3. Insert the Crisis Recovery Diskette into the A: diskette drive. (See the section titled Crisis

Recovery Diskette on page 47 for instructions on creating the diskette.)

4. Plug the system into the AC power source and power it on.

5. A blue screen will be displayed and the recovery process will automatically run. The system will continue to beep throughout the recovery process. The recovery process is complete when the beeping stops.

6. Remove the diskette.

7. Power down and unplug the system from the AC power source.

8. Move the BIOS recovery jumper at J32 back to the original position, covering storage pins

9 and 10.

9. Plug the system into the AC power source and power it up to confirm that the recovery was successful.

Solving Problems 83

Clearing the Password

If the user or administrator password(s) is lost or forgotten, moving the password clear jumper into the “clear” position clears both passwords. The password clear jumper must be restored to its original position before a new password(s) can be set. The password clear jumper is located on jumper block J32 on the SE7501CW2 board.

1. Power down the system and disconnect the AC power.

2. Open the server chassis.

3. Move the jumper from the spare at pins 9 and 10 to the Clear Password position, covering pins

1 and 2 as indicated in the following diagram.

Main Power

10

8

6

4

2

J32

5

3

1

9

7

Figure 29. Password Recovery Jumper

4. Reconnect the AC power, power up the system.

5. Power down the system and disconnect the AC power.

6. Return the Password Clear jumper to the spare location, covering pins 9 and 10.

7. Close the server chassis.

TP00097

84 Intel Server Board SE7501CW2 Product Guide

Clearing the CMOS

If you are not able to access the BIOS setup screens, the CMOS Clear jumper will need to be used to reset the configuration RAM. The CMOS Clear jumper is located on jumper block J32 on the

Server Board SE7501CW2.

1. Power down the system and disconnect the AC power.

2. Open the server.

3. Move the jumper from the spare location at pins 9 and 10 to the Clear CMOS position, covering pins 5 and 6 as indicated in the following diagram.

Main Power

10

8

6

4

2

J32

9

7

5

3

1

Figure 30. CMOS Recovery Jumper

4. Reconnect the AC power, power up the system.

5. When the system begins beeping, power it down and disconnect the AC power.

6. Return the CMOS Clear jumper to the spare location, covering pins 9 and 10.

7. Close the server chassis, reconnect the AC power and power up the system.

TP00098

Solving Problems 85

86 Intel Server Board SE7501CW2 Product Guide

World Wide Web

http://support.intel.com/support/motherboards/server/SE7501CW2

Telephone

All calls are billed US $25.00 per incident, levied in local currency at the applicable credit card exchange rate plus applicable taxes. (Intel reserves the right to change the pricing for telephone support at any time without notice).

In U.S. and Canada 1-800-404-2284

In Europe

Finland 9 693 79297

France 01 41 918529

Italy

Spain

02 696 33276

91 377 8166

In Asia-Pacific region

Hong Kong 852 2 844 4456

Korea

PRC

822 767 2595

800 820 1100

Norway

Sweden

Holland

23 1620 50

08 445 1251

020 487 4562

Indonesian 001-803 65 7249

Malaysia 1-800 80 1390

New Zealand 0800 444 365

Pakistan 632 6368415 (IDD via Philippines)

Philippines 1-800 1 651 0117

Taiwan

2 2545-1640

In Japan

0120-868686 (Domestic)

Vietnam 632 6368416 (IDD via Philippines)

81-298-47-0800 (outside country)

In Latin America

Brazil 0021-0811-408-5540

Mexico 001-800-628-8686

Colombia 980-9-122-118

Costa Rica 0-800-011-0395

Panama 001-800-628-8686

Chile 800-532-992

Miami 1-800-621-8423

Ecuador 999-119, 800-628-8686 (via AT&T)

Guatemala 99-99-190, 800-628-8686 (via AT&T)

Venezuela 800-11-120, 800-628-8686 (via AT&T)

Paraguay 008-11, 800-628-8686 (via AT&T)

Peru 0-800-50000, 800-628-8686 (via AT&T)

Uruguay 000-410, 800-628-8686 (via AT&T)

For an updated support contact list, see

http://www.intel.com/support/9089.htm/

87

88 Intel Server Board SE7501CW2 Product Guide

Configuration Jumpers

Main Power

10

8

6

4

2

J32

9

7

5

3

1

TP00092

Figure 31. Configuration Jumper Location

Table 28. Configuration Jumper (J32)

Jumper Name Pins What happens at system reset

Spare location

BIOS Boot Block

Write Protect

CMOS Clear

BIOS Recovery

Password Clear

9-10 Leave the jumper here unless performing one of the operations below..

7-8 These pins, when jumpered, protect the BIOS Boot Block code. If it becomes necessary to update the BIOS Boot Block, this jumper should be removed during the update process. These pins should be jumpered for normal operation.

5-6

NOTE: This jumper should remain in place for normal BIOS operational code updates.

If these pins are jumpered, the CMOS settings will be cleared on the next reset. These pins should not be jumpered for normal operation.

3-4

1-2

If these pins are jumpered, the system will attempt BIOS recovery. These pins should not be jumpered for normal operation.

If these pins are jumpered, the password will be cleared on the next reset.

These pins should not be jumpered for normal operation.

NOTE

The jumper should remain on pins 7-8 at all times unless you are instructed to perform a BIOS Boot Block update. At this time, remove the jumper, run the BIOS update, and then replace the jumper when completed.

89

Front Panel Header

The front panel header provides connection to the front panel for power switching and LED operation.

90

A

2

1

C

D

E F

B

G

34

33

OM14434

Figure 32. Front Panel Header Connection Location

D

E

F

G

Table 29. Front Panel Header Connection Descriptions

Location Pins Description

A

B

C

12 & 14

22 & 24

1 & 5

LED shows network interface controller activity

LED shows network interface controller activity

LED shows power on

7 & 9

11 & 13

15 & 17

23

LED shows hard drive activity

Pressing the power switch removes all by standby power from the board

Pressing the reset button restarts the boot process

Pressing the NMI button causes a non-maskable interrupt

Intel Server Board SE7501CW2 Product Guide

7 Regulatory and Integration Information

Product Regulatory Compliance

Product Safety Compliance

The Server Board SE7501CW2 complies with the following safety requirements:

UL 1950 - CSA 950 (US/Canada)

EN 60 950 (European Union)

IEC60 950 (International)

CE – Low Voltage Directive (73/23/EEC) (European Union)

EMKO-TSE (74-SEC) 207/94 (Nordics)

GOST R 50377-92 (Russia)

Product EMC Compliance

The Server Board SE7501CW2 has been has been tested and verified to comply with the following electromagnetic compatibility (EMC) regulations when installed a compatible Intel

®

host system.

For information on compatible host system(s) refer to Intel’s Server Builder Web site or contact your local Intel representative.

FCC (Class A Verification) – Radiated & Conducted Emissions (USA)

ICES-003 (Class A) – Radiated & Conducted Emissions (Canada)

CISPR 22, 3 rd

Edition (Class A) – Radiated & Conducted Emissions (International)

EN55022 (Class A) – Radiated & Conducted Emissions (European Union)

EN55024 (Immunity) (European Union)

CE – EMC Directive (89/336/EEC) (European Union)

VCCI (Class A) – Radiated & Conducted Emissions (Japan)

AS/NZS 3548 (Class A) – Radiated & Conducted Emissions (Australia / New Zealand)

RRL (Class A) Radiated & Conducted Emissions (Korea)

BSMI CNS13438 (Class A) Radiated & Conducted Emissions (Taiwan)

GOST R 29216-91 (Class A) Radiated & Conducted Emissions (Russia)

GOST R 50628-95 (Immunity) (Russia)

91

Product Regulatory Compliance Markings

This product is marked with the following Product Certification Markings:

Table 30. Product Certification Markings

UL Recognition Mark

CE Mark

Russian GOST Mark

Australian C-Tick Mark

BSMI DOC Marking

BSMI EMC Warning

RRL MIC Mark

Electromagnetic Compatibility Notices

FCC (USA)

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

For questions related to the EMC performance of this product, contact:

5200 N.E. Elam Young Parkway

Hillsboro, OR 97124

1-800-628-8686

92 Intel Server Board SE7501CW2 Product Guide

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and the receiver.

Connect the equipment to an outlet on a circuit other than the one to which the receiver is connected.

Consult the dealer or an experienced radio/TV technician for help.

Any changes or modifications not expressly approved by the grantee of this device could void the user’s authority to operate the equipment.

The customer is responsible for ensuring compliance of the modified product.

Only peripherals (computer input/output devices, terminals, printers, etc.) that comply with FCC

Class A or B limits may be attached to this computer product. Operation with noncompliant peripherals is likely to result in interference to radio and TV reception.

All cables used to connect to peripherals must be shielded and grounded. Operation with cables, connected to peripherals, that are not shielded and grounded may result in interference to radio and

TV reception.

Industry Canada (ICES-003)

This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the interference-causing equipment standard entitled: “Digital Apparatus,”

ICES-003 of the Canadian Department of Communications.

Cet appareil numérique respecte les limites bruits radioélectriques applicables aux appareils numériques de Classe A prescrites dans la norme sur le matériel brouilleur: “Apparelis

Numériques”, NMB-003 édictee par le Ministre Canadian des Communications.

Europe (CE Declaration of Conformity)

This product has been tested in accordance too, and complies with the Low Voltage Directive

(73/23/EEC) and EMC Directive (89/336/EEC). The product has been marked with the CE Mark to illustrate its compliance.

Taiwan Declaration of Conformity

This product has been tested and complies with CNS13438. The product has been marked with the

BSMI DOC mark to illustrate compliance.

Regulatory and Integration Information 93

Korean RRL Compliance

This product has been tested and complies with MIC Notices No. 1997-41 and 1997-42. The product has been marked with the MIC logo to illustrate compliance.

The English translation for the above is as follows:

1. Type of Equipment (Model Name): SE7501CW2

2. Certification No.: Contact Intel Representative

3. Name of Certification Recipient: Intel

4. Date of Manufacturer: Marked on Product

5. Manufacturer / Nation : Intel

Australia / New Zealand

This product has been tested and complies with AS/NZS 3548. The product has been marked with the C-Tick mark to illustrate compliance.

94 Intel Server Board SE7501CW2 Product Guide

Index

A

ACPI, 19

APIC, 11

ATI* Rage XL, 15 audible beep error codes, 23

B

Back Panel Connectors, 8 battery disposing of safely, 69 installing, 70 removing, 69 beep codes, 23

BIOS, 12, 18, 19, 20 changing the language, 49 upgrading, 45, 46 bootable media required by POST, 23 booting cold, 75

Bridge, 7

C

cable

CPU fan, 67, 68

Caution avoid damaging jumpers when changing,

52 avoid touching processor pins, 62 selecting correct processor, 62

CMOS clear to reconfigure diskette drive, 24

Configuration, 19, 25 configuring server board jumpers location on server board, 89 configuring system

Setup, 23 connector

NIC, 18

RJ45, 18 controller

Ethernet, 8 network, 7, 17 video, 7

Controller, 12

CPU fan cable install, 67 removing, 68

D

diagnostics preparing system for testing, 77

DIMM, 13 diskette running SCU from, 23

E

ECC, 13 embedded NIC, disabling, 17

EMC compliance, 17

ESD add-in boards, 52 avoiding damage to product, 52 do not touch processor pins, 62

Ethernet, 7, 8, 15

Ethernet controllers, 8

Exit menu, configuring, Setup, 44

F

fan heat sink, disconnecting, 68

Fast Ethernet, 7, 8, 17 feature summary back panel connectors, 8

Flip Chip Pin Grid Array, 7 form factor, 8 front panel header location on server board, 90

Front Panel reset, 20

G

Getting Help, 87 gigabit ethernet controller, 17

95

H

Hardware Monitoring, 49 heat sink fan, 68 installation, 65

HI 2.0 bus, 11

I

I/O

PCI expansion slots, 7 ports provided, 8

I/O shield, 67

ICH3-S, 11

IDE interface, 11

Intel

®

82540, 8, 15, 17

Intel

®

82550, 7, 8, 15, 17

Intel® E7501 chipset, 7

Interrupt controller, 11

J

JEDEC, 13 jumpers do not damage when changing, 52

L

language changing in BIOS, 49 lithium backup battery disposing of safely, 69 installing, 70 removing, 69

LPC, 11

M

MCH, 11 memory capacity, 7 mimimum, 13 requirements, 61 video amount, 7 what type to install, 7

96

N

network controller, 7, 17

Network, 18

NIC

LED, 18

North Bridge, 7, 11

NVRAM, 44

P

Parallel, 12 password, 21 administrator, 21 forgotten, 84

Password, 20 password clear jumper, 84

PCI

32-bit / 33MHz, 14 embedded devices, 7 expansion slots, 7

PCI bus segments, 14

PCI-X, 14

PCI-X 64-bit / 100MHz, 14

POST, 23 bootable media required, 23

Power management, 11 problems after running new application software, 76 after system has been running correctly,

76 application software, 81

BIOS recovery, 82 bootable CD-ROM not detected, 81, 85 cannot connect to network server, 80

CD-ROM drive activity light, 80 confirm OS loading, 77 diskette drive light, 79 initial system startup, 75 network, 80 no characters on screen, 78

PCI installation tips, 81 power light, 78 preparing system for diagnostic testing, 77 random error in data files, 76 screen characters incorrect, 79 system cooling fans do not rotate, 79

Intel Server Board SE7501CW2 Product Guide

system lights, 77 processor adding second processor, 62 apply thermal grease, 64 heat sink, 65 installing, 62 packaging, 7 replacing, 68 retention clips, 65 processor speed, 10

Processor Wind Tunnel alignment, 67 installation, 67 installing, 62, 64 retention clips, 65, 68 retention device, 64, 68

Processor Wind Tunnel fan installation, 66 processor(s) what type to install, 7, 10, 62

PWT, 62

R

real time clock running SCU to configure settings, 70 reset system, 75

RTC, 19

S

SDRAM, 13

Sensor Event, 20

Serial, 12 server board component locations, figure, 9 configurations, 89

Setup

Advanced menu, 29 cannot enter, 24 changing configuration, 23 description, 24

Exit menu, 44

Main menu, 27

Security Menu, 41, 42, 43, 44

Setup Utility, 19

SGRAM, 15 soft boot, 75

South Bridge, 7, 11

Switches

DC power, 75 reset, 75

T

Transfer Mode, 28

U

upgrade Flash utility, 45

USB, 16 utilities

Setup, 23, 24

V

video memory, 7 video controller, 7

Video Controller, 15

W

Wake on LAN, 19

Wake on Ring, 20

Warning dispose of lithium battery safely, 69

ESD can damage product, 52

Index 97

98 Intel Server Board SE7501CW2 Product Guide

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement

Table of contents