Bürkert 2730, 2731, K diaphragm control valve Operating Instructions
PDF
Документ
Реклама
Реклама
Type 2730, 2731, 2731 K DN 15 - 50 Piston controlled diaphragm control valve Kolbengesteuertes Membranregelventil Vanne de réglage à membrane commandée par piston Operating Instructions Bedienungsanleitung Manuel d‘utilisation We reserve the right to make technical changes without notice. Technische Änderungen vorbehalten. Sous réserve de modifications techniques. © Bürkert Werke GmbH & Co. KG, 200 - 2017 Operating Instructions 1706/_EU-EN_008 / Original DE Type 2730, 2731 and 2731 K 1 Operating instructions.................................................................4 1.1 Definition of term “device”........................................................ 4 1.2 Symbols........................................................................................ 4 2 Authorized use.......................................................................................5 3 Basic safety instructions...........................................................5 4 General information.........................................................................6 4.1 Contact address......................................................................... 6 4.2 Warranty....................................................................................... 6 4.3 Information on the internet....................................................... 6 5 Product description.........................................................................7 5.1 General description................................................................... 7 5.2 Properties..................................................................................... 7 5.3 Structure and function.............................................................. 7 6 Technical data.........................................................................................8 6.1 Conformity.................................................................................... 8 6.2 Standards..................................................................................... 8 6.3 Type label..................................................................................... 8 6.4 Labeling of the forged bodies................................................. 9 6.5 Labeling of the tube valve body (VP)..................................... 9 6.6 Operating conditions...............................................................10 6.7 Flow values and characteristics............................................16 6.8 General technical data............................................................16 7 Installation............................................................................................. 17 7.1 Before installation.....................................................................17 7.2 7.3 Installation..................................................................................19 Pneumatic connection.............................................................20 8 Removal....................................................................................................... 21 9 Electrical control unit............................................................. 21 10 Malfunctions......................................................................................... 22 11 Maintenance............................................................................................ 22 11.1 Maintenance and cleaning.....................................................22 11.2 Replacing the diaphragm.......................................................24 12 Replacement parts........................................................................... 26 12.1 Order table.................................................................................27 13 Packaging, transport, storage........................................... 28 english 3 Type 2730, 2731 and 2731 K Operating instructions 1 Operating instructions The operating instructions describe the entire life cycle of the device. Keep these instructions in a location which is easily accessible to every user and make these instructions available to every new owner of the device. 1.2 Danger! Warns of an immediate danger. ▶▶ Failure to observe the warning may result in a fatal or serious injury. Warning! Important safety information. Failure to observe these instructions may result in hazardous situations. ▶▶ The operating instructions must be read and understood. Symbols Warns of a potentially dangerous situation. ▶▶ Failure to observe the warning may result in serious injuries or death. Caution! 1.1 Definition of term “device” The term “device” used in these instructions always stands for the diaphragm control valve Type 2730, 2731 and 2731 K. Warns of a possible danger. ▶▶ Failure to observe this warning may result in a moderately severe or minor injury. Note! Warns of damage to property. Important additional information, tips and recommendations. Refers to information in these operating instructions or in other documentation. ▶▶ designates instructions for risk prevention. →→designates a procedure which you must carry out. 4 english Type 2730, 2731 and 2731 K Authorized use 2 Authorized use Non-authorized use of the diaphragm control valve Type 2730, 2731 and 2731 K may be a hazard to people, nearby equipment and the environment. ▶▶ The device is designed for the controlled flow of liquid media. ▶▶ In the potentially explosion-risk area Type 2730, 2731 and 2731 K may be used only according to the specification on the separate Ex type label. For use observe the additional information enclosed with the device together with safety instructions for the explosionrisk area. ▶▶ Devices without a separate Ex type label may not be used in a potentially explosive area. ▶▶ The admissible data, the operating conditions and conditions of use specified in the contract documents, operating instructions and on the label are to be observed during use. The designated application cases are specified in the chapter entitled “5 Product description”. ▶▶ The device may be used only in conjunction with third-party devices and components recommended and authorised by Bürkert. ▶▶ Correct transportation, correct storage and installation and careful use and maintenance are essential for reliable and faultless operation. ▶▶ Use the device only as intended. 3 Basic safety instructions These safety instructions do not make allowance for any • contingencies and events which may arise during the installation, operation and maintenance of the devices. • local safety regulations, whereby the operator is responsible for their compliance, by the installation personnel too. Danger! Danger – high pressure. ▶▶ Before dismounting the lines and valves, turn off the pressure and vent the lines. Risk of electric shock. ▶▶ Before reaching into the device, switch off the power supply and secure to prevent reactivation. ▶▶ Observe applicable accident prevention and safety regulations for electrical equipment. Risk of injury when opening the actuator. The actuator contains a tensioned spring. If the actuator is opened, there is a risk of injury from the spring jumping out! ▶▶ The actuator must not be opened. Risk of burns. The surface of the device may become hot during long-term operation. ▶▶ Do not touch the device with bare hands. english 5 Type 2730, 2731 and 2731 K General information General hazardous situations. To prevent injury, ensure that: ▶▶ The system cannot be activated unintentionally. ▶▶ Installation and repair work may be carried out by authorized technicians only and with the appropriate tools. ▶▶ After an interruption in the power supply or pneumatic supply, ensure that the process is restarted in a defined or controlled manner. ▶▶ The device may be operated only when in perfect condition and in consideration of the operating instructions. ▶▶ The general rules of technology apply to application planning and operation of the device. To prevent damage to property on the device, ensure: ▶▶ Supply the media connections only with those media which are specified as flow media in the chapter entitled “6 Technical data”. ▶▶ Do not put any loads on the valve (e.g. by placing objects on it or standing on it). ▶▶ Do not make any external modifications to the valves. Do not paint the body parts or screws. 4 General information 4.1 Contact address Germany Bürkert Fluid Control Systems Sales Center Christian-Bürkert-Str. 13-17 D-74653 Ingelfingen Tel.: + 49 (0)7940 - 10 91 111 Fax: + 49 (0)7940 - 10 91 448 E-mail: [email protected] International Contact addresses are found on the final pages of the printed operating manual. You can also find information on the Internet under: www.burkert.com 4.2 Warranty The warranty is only valid if the device is used as authorized in accordance with the specified application conditions. 4.3 Information on the internet The operating instructions and data sheets for Type 2730, 2731 and 2731 K can be found on the Internet at: www.burkert.com 6 english Type 2730, 2731 and 2731 K Product description 5 Product description 5.1 General description The piston-controlled diaphragm control valve Type 2730, 2731 and 2731K is suitable for liquid media. Using neutral gases or air (control media), it controls the flow of dirty, aggressive, ultrapure or sterile media, even highly viscous media can be used (flow media). The operation of the diaphragm control valve Type 2730, 2731 and 2731K is possible only in combination with an control unit. 5.2 Properties 5.3 Structure and function The operation of the diaphragm control valve Type 2730, 2731 and 2731 K is possible only in combination with an control unit. Possible control units are: Positioner Type 8635, 8692, 8694, 8792 Process controller Type 8693, 8793 5.3.1 Structure The piston-controlled diaphragm control valve consists of a pneumatically operated piston actuator and a 2/2-way valve body. • Any flow direction. • Self-draining for appropriate installation. The ends of the utilized connections must be cylindrical. Actuator cover • Free of empty space. Actuator body • Low-turbulence flow. • High flow values by the streamlined valve body. Upper pilot air port • Maintenance-free under normal conditions. Lower pilot air port 5.2.1 Diaphragm socket Actuator sizes Diaphragm The piston-controlled diaphragm control valve is available for the following actuator sizes: ø 80 mm, ø 100 mm, ø 125 mm. Line connection 5.2.2 Valve body Pilot pressure Designs with lower pilot pressure (reduced spring force) are available on request. Fig. 1: Structure and description english 7 Type 2730, 2731 and 2731 K Technical data 5.3.2 Function Spring force (CFA) or pneumatic pilot pressure (CFB) generates the closing force on the diaphragm pressure piece. The force is transferred via a spindle which is connected to the actuator piston. Control function A (CFA) Normally closed by spring action 6 Technical data 6.1 Conformity In accordance with the EU Declaration of conformity, the diaphragm control valve Type 2730, 2731 and 2731 K is compliant with the EU Directives. Control function B (CFB) 6.2 Standards Normally open by spring action The applied standards, which verify conformity with the EU Directives, can be found on the EU-Type Examination Certificate and / or the EU Declaration of Conformity. 6.3 Type label Control function Orifice (diaphragm size) Type Made in Germany Sealing material 2731 A 25,0 EPDM VA D29 Pmed 10 bar Pilot 5,5-7 bar Body material Line connection / Permitted medium pressure Permitted pilot pressure 00148320 W14UN Date of manufacture Identification number Fig. 2: 8 english Type label (example) Type 2730, 2731 and 2731 K Technical data 6.4 Labeling of the forged bodies 6.5 Batch number XX F XXXXXXXX/XXX 1.4435/316L(VS) XXXX PN16/CWP150 XXXXXX XXXXXXXXXX Material Material Company logo Heat Production number / serial number 1.4435 316L(VP) Self-drain angle XXXXXXXX Customer-specific text (optional) Nominal pressure Orifice connection and pipe dimension Fig. 3: Labeling of the tube valve body (VP) Nominal PN16 / CWP150 pressure Labeling of the forged bodies XXXXXXXXXX Production number / serial number XXXXXXXX / XXX XXXX / XXXXXX Fig. 4: Connection orifice and pipe dimensions Self-drain angle / Customer-specific text (optional) Labeling of the tube valve body (VP) english 9 Type 2730, 2731 and 2731 K Technical data 6.6 Operating conditions Warning! Risk of injury, chemical burns, scalding due to the device rupturing at excessively high pressure. ▶▶ Do not exceed the maximum pilot and medium pressure. ▶▶ Observe permitted ambient and medium temperature. ▶▶ Observe specifications on the type label. 6.6.1 Temperature ranges Permitted ambient temperature actuators Actuator size ø 80 mm Actuator material ø 100 mm PA, PPS Ambient temperature1) -10 – +60 °C ø 125 mm Tab. 1: Permitted ambient temperature actuators 1) If using a pilot valve / control unit, observe its temperature range. Permitted medium temperature for body lastic body: note that the permissible medium pressure is P dependent on the medium temperature (see “Fig. 5: Graph of medium pressure / medium temperature”). 10 english Body material Medium PVDF (PD) -10 – +120 °C PP (PP) -10 – +80 °C PVC (PV) -10 – +60 °C Tube valve body (VP) 1.4404 (AISI 316L) Cast body (VG) 1.4435 (AISI 316L) Forged body (VS) 1.4435 BN2 (AISI 316L) according to ASME BPE 1997 -10 – +150 °C Tab. 2: Permitted medium temperature for body Permitted medium temperature for diaphragms he indicated medium temperatures apply only to media T which do not corrode or swell the diaphragm materials. The behavior of the medium with respect to the diaphragm may be changed by the medium temperature. The function properties, in particular the service life of the diaphragm, may deteriorate if the medium temperature increases. Do not use the diaphragms as steam shut-off element. Material Temperature Remarks EPDM (AB) -10...+130 °C Steam sterilisation up to +140 °C / 60 min EPDM (AD) -5...+143 °C Steam sterilisation up to +150 °C / 60 min FKM (FF) 0...+130 °C No steam / dry heat up to +150 °C / 60 min PTFE (EA) -10...+130 °C Steam sterilisation up to +140 °C / 60 min Type 2730, 2731 and 2731 K Technical data Material Temperature Remarks Advanced PTFE (EU) -5...+143 °C Steam sterilisation up to +150 °C / 60 min Advanced PTFE (ET) -10...+90 °C - Gylon (ER) -5...+130 °C Steam sterilisation up to +140 °C / 60 min Tab. 3: Permitted medium temperature for diaphragms 6.6.2 Maximum pilot pressure for valves without pneumatic position controller - only control function B and tube valve body (VP) Actuator size [mm] Actuator material Max. permitted pilot pressure2) ø 80, ø 100, ø 125 6 bar Pressure ranges bserve the maximum pressure range according to the type O label! 2) Pilot pressure for valves with pneumatic position controller Actuator size [mm] Pilot pressure ø 80, ø 100, ø 125 5.5 – 7.0 bar Tab. 4: Pilot pressure for valves with pneumatic position controller Maximum pilot pressure for valves without pneumatic position controller Max. permitted pilot pressure2) ø 80, ø 100 PA 10 bar ø 125 PA 7 bar ø 80, ø 100, ø 125 PPS 7 bar Tab. 5: Pilot pressure for valves without pneumatic position controller lastic body: note that the permissible medium pressure is P dependent on the medium temperature (see “Fig. 5”). 10 Fig. 5: 8 PV DF 6 4 C PV Actuator size [mm] Actuator material Medium pressure for plastic body Medium pressure [bar] To ensure reliable operation with pneumatic position controller, observe the permitted minimum and maximum pilot pressure! PA, PPS Tab. 6: Maximum pilot pressure for valves without pneumatic position controller - only CFB and tube valve body (VP) 2 0 20 40 PP 60 80 Medium temperature [°C] 100 120 140 Graph of medium pressure / medium temperature english 11 Type 2730, 2731 and 2731 K Technical data Operating pressure for control function A3) The values apply to The values apply to • Plastic body PVDF (PD), PP (PP), PVC (PV) • Tube valve body (VP) withDIN weld end connection DIN clamp connection • Forged steel body (VS) • Precision casting body (VG) Max. sealed medium pressure [bar] Pressure on one Pressure on both side sides EPDM/FKM PTFE EPDM/FKM 15 10 10 10 ø 80 20 10 10 10 25 10 7.5 8.5 ø 100 32 10 8 9 40 10 10 10 ø 125 50 8 7 7 Tab. 7: Operating pressure for control function A PTFE 10 10 5.5 6 9 6 Actuator size [mm] Orifice DN (Diaphragm size) [mm] Actuator size [mm] • Tube valve body (VP) withISO weld end connection ISO clamp connection Threaded connection Welded neck flange english Max. sealed medium pressure [bar] Pressure on one Pressure on both side sides EPDM/FKM PTFE EPDM/FKM 15 10 10 10 20 10 10 10 ø 80 25 10 10 10 32 10 8 7.5 ø 100 40 10 8 8 ø 125 50 10 10 10 Tab. 8: Operating pressure for control function A 3) 12 Orifice DN (Diaphragm size) [mm] Operating pressure for control function A3) he control functions are described in the chapter entitled “5.3.2 T Function”. PTFE 10 10 9 6 6 8.5 Type 2730, 2731 and 2731 K Technical data Operating pressure for control function A3) Required minimum pilot pressure depending on medium pressure for control function B. PTFE EPDM/FKM 20 10 10 10 25 10 10 10 ø 100 40 10 8 8 ø 125 50 10 10 10 Tab. 9: Operating pressure for control function A ø 80 PTFE 10 9 6 8.5 • Forged steel body (VS) • Precision casting body (VG) • Tube valve body (VP) withISO- weld end connection ISO clamp connection Threaded connection Welded neck flange To protect the diaphragm during control function B, preferably do not select the pilot pressure higher than is required to switch the medium pressure. Control function B / elastomer diaphragm ø 80 EPDM Fig. 6: 10 9 8 7 6 5 4 3 2 1 0 0 1 DN20 EPDM/FKM • Plastic body PVDF (PD), PP (PP), PVC (PV) DN15 Max. sealed medium pressure [bar] Pressure on one Pressure on both side sides The values in the following graphs apply to: DN25 Orifice DN (Diaphragm size) [mm] Actuator size [mm] • Tube valve body (VP) withOD weld end connection BS clamp connection Medium pressure [bar] The values apply to 2 3 4 5 Pilot pressure [bar] 6 7 8 P ressure graph, actuator ø 80 mm, control function B, elastomer diaphragm english 13 Type 2730, 2731 and 2731 K DN50 • Tube valve body (VP) with DIN weld end connection DIN clamp connection To protect the diaphragm during control function B, preferably do not select the pilot pressure higher than is required to switch the medium pressure. 2 3 4 5 Pilot pressure [bar] 6 7 8 P ressure graph, actuator ø 100 mm and ø 125 mm, control function B, elastomer diaphragm Control function B / elastomer diaphragm ø 80 EPDM DN40 DN32 DN15 DN20 DN25 Control function B / PTFE diaphragm Medium pressure [bar] ø 80, ø 100, ø 125 PTFE Fig. 8: 14 10 9 8 7 6 5 4 3 2 1 0 DN50 Fig. 9: 0 1 2 3 4 5 Pilot pressure [bar] 6 7 P ressure graph, actuator ø 80 mm, ø 100 mm and ø 125 mm, control function B, PTFE diaphragm english 8 10 9 8 7 6 5 4 3 2 1 0 0 1 DN25 1 DN15 DN20 0 DN32 Fig. 7: 10 9 8 7 6 5 4 3 2 1 0 The values in the following graphs apply to: Medium pressure [bar] Medium pressure [bar] ø 100, ø 125 EPDM DN32 DN40 Technical data 2 3 4 5 Pilot pressure [bar] 6 7 8 Pressure graph, actuator ø 80 mm, control function B, elastomer diaphragm Type 2730, 2731 and 2731 K • Tube valve body (VP) with OD weld end connection BS clamp connection To protect the diaphragm during control function B, preferably do not select the pilot pressure higher than is required to switch the medium pressure. 0 1 2 3 4 5 Pilot pressure [bar] 6 7 8 Fig. 10: P ressure graph, actuator ø 100 mm and ø 125 mm, control function B, elastomer diaphragm Medium pressure [bar] ø 80, ø 100, ø 125 PTFE 10 9 8 7 6 5 4 3 2 1 0 DN50 DN40 DN15 DN20 DN25 DN32 Control function B / PTFE diaphragm Control function B / elastomer diaphragm DN20 DN25 10 9 8 7 6 5 4 3 2 1 0 The values in the following graphs apply to: ø 80 EPDM Medium pressure [bar] Medium pressure [bar] ø 100, ø 125 EPDM DN40 DN50 Technical data 10 9 8 7 6 5 4 3 2 1 0 0 1 2 3 4 5 Pilot pressure [bar] 6 7 8 Fig. 12: Pressure graph, actuator ø 80 mm, control function B, elastomer diaphragm 0 1 2 3 4 5 Pilot pressure [bar] 6 7 8 Fig. 11: P ressure graph, actuator ø 80 mm, ø 100 mm and ø 125 mm, control function B, PTFE diaphragm english 15 Type 2730, 2731 and 2731 K Medium pressure [bar] ø 100, ø 125 EPDM 10 9 8 7 6 5 4 3 2 1 0 6.7 DN40 DN50 Technical data Flow values and characteristics for Types 2730, 2731 and 2731 K you find at www.burkert.com → Type 2730. 6.8 Connections 0 1 2 3 4 5 Pilot pressure [bar] 6 7 8 Line connection Type 2730 Socket and spigot Materials DN50 DN40 DN20 DN25 Medium pressure [bar] ø 80, ø 100, ø 125 PTFE Pilot air portG1/4, stainless steel Type 2731 / 2731KWeld end: in accordance with EN ISO 1127 (ISO 4200), DIN 11850 R2 other connections on request Control function B / PTFE diaphragm Body Type 2730PVDF (PD), PP (PP), PVC (PV) Type 2731 Stainless steel precision casting (VG) 1.4435 (AISI 316L), Stainless steel forged steel (VS) 1.4435 (AISI 316L) 0 1 2 3 4 5 Pilot pressure [bar] 6 7 Fig. 14: P ressure graph, actuator ø 80 mm, ø 100 mm and ø 125 mm, control function B, PTFE diaphragm 16 General technical data Actuator sizesø 80 mm, ø 100 mm, ø 125 mm Fig. 13: P ressure graph, actuator ø 100 mm and ø 125 mm, control function B, elastomer diaphragm 10 9 8 7 6 5 4 3 2 1 0 Flow values and characteristics english 8 Type 2731KTube valve body (VP) cold-formed 1.4404 (316L) Actuator PA, PPS Sealing elements actuator FKM, NBR Type 2730, 2731 and 2731 K Installation DiaphragmEPDM in food quality, PTFE/EPDM, FKM Media Control mediumNeutral gases, air Quality classes in accordance with DIN ISO 8573-1 Dust content 7 Installation Danger! Danger – high pressure in the equipment. ▶▶ Before loosening the lines and valves, turn off the pressure and vent the lines. Class 5:max. particle size 40 μm, max. particle density 10 mg/m³ Warning! Water content Class 3:max. pressure dew point - 20 °C or min. 10 °C below the lowest operating temperature Risk of injury from improper installation. ▶▶ Installation may be carried out by authorised technicians only and with the appropriate tools! Oil content Risk of injury from unintentional activation of the system and an uncontrolled restart. ▶▶ Secure system from unintentional activation. ▶▶ Following assembly, ensure a controlled restart. Class 5:max. 25 mg/m³ with TopControl maxi 1 mg/m³ with SideControl Flow media Type 2730Liquids; aggressive or abrasive media Type 2731 / 2731KLiquids; ultrapure, sterile, aggressive or abrasive media 7.1 Viscosity • Before connecting the valve, ensure the pipelines are flush. up to viscous Before installation • The flow direction is optional. Installation positionany position, preferably with the actuator face up Protection classIP67 in accordance with IEC 529 / EN 60529 7.1.1 Installation position general Installation for self-drainage of the body It is the responsibility of the installer and operator to ensure self-drainage. english 17 Type 2730, 2731 and 2731 K Installation Installation for leakage detection 7.1.3 7.1.2 Preparatory work →→Clean pipelines (sealing material, swarf, etc.). →→Support and align pipelines. One of the bores (in the actuator base) for monitoring leakage must be at the lowest point. Devices with VG/VS/VA welded body: Installation position 2/2-way valve The piston-controlled diaphragm control valve can be installed in any installation position, preferably with the actuator face up. To ensure self-drainage: →→Install body inclined by an angle α = 15° – 35° to the horizontal. →→Observe an inclination angle of 1° – 5° to the line axis. Forged and cast body: Mark on the body must point upwards (12 o’clock position, see “Fig. 15”). →→One of the bores (in the actuator base) for monitoring leakage must be at the lowest point. Mark Note! Damage to the diaphragm or the actuator! ▶▶ Before welding in the body, remove the actuator. Remove the actuator from the valve body: Note! Damage to the diaphragm or the seat contour! ▶▶ When removing the actuator, ensure that the valve is in open position. →→Control function A pressurize the lower pilot air port with compressed air (5 bar): valve opens. α →→Remove actuator with diaphragm by loosening the body screws. Actuator Angle α: 15 °– 35° Inclination to the line axis 1° – 5° Upper pilot air port Fig. 15: Installation position for self-drainage of the body Lower pilot air port Diaphragm Body screws (4x) Valve body Fig. 16: Installation 18 english Type 2730, 2731 and 2731 K Installation 7.2 Installation Warning! Risk of injury from improper installation. Non-observance of the tightening torque is dangerous as the device may be damaged. ▶▶ Observe the tightening torque (see “Tab. 10: Tightening torques for diaphragms”). 7.2.1 Installation of the valve body Welded bodies →→Weld valve body in pipeline system. →→Without pressurization tighten the body screws to the permitted tightening torque (see following table “Tab. 10: Tightening torques for diaphragms”). Installation for actuator with control functions B: →→Lightly cross-tighten the body screws without pressurization until the diaphragm is between the body and actuator. Do not tighten the screws yet. →→Pressurize upper pilot air port of the actuator with compressed air (5 bar). →→Actuate the diaphragm control valve twice. →→With pressurization tighten the body screws to the permitted tightening torque (see “Tab. 10: Tightening torques for diaphragms”). Other body versions →→Connect body to pipeline. 7.2.2 Installation of the actuator (welded body) Installation for actuator with control function A: Notice! Damage to the diaphragm or the seat contour! ▶▶ When installing the actuator, ensure that the valve is in open position. →→Control function A pressurize the lower pilot air port with com- Orifice DN (diaphragm size) Tightening torques for diaphragms [Nm] EPDM PTFE 15 3.5 4 20 4 4.5 25 5 6 32 6 8 40 8 10 50 12 15 Tab. 10: Tightening torques for diaphragms pressed air (5 bar): valve opens. →→Lightly cross-tighten the body screws until the diaphragm is between the body and actuator. Do not tighten the screws yet. →→Actuate the diaphragm control valve twice. english 19 Type 2730, 2731 and 2731 K Installation 7.3 Pneumatic connection DANGER! 7.3.1 Connection of the actuator Control functions A: Danger – high pressure in the equipment. ▶▶ Before loosening the lines and valves, turn off the pressure and vent the lines. →→Connect the control medium to the lower pilot air port of the actuator (see “Fig. 17: Pneumatic connection”) Control functions B: →→Connect the control medium to the upper pilot air port of the Warning! actuator (see “Fig. 17: Pneumatic connection”) Risk of injury from unsuitable connection hoses. Hoses which cannot withstand the pressure and temperature range may result in hazardous situations. ▶▶ Use only hoses which are authorised for the indicated pressure and temperature range. ▶▶ Observe the data sheet specifications from the hose manufacturers. Silencer For reducing the exhaust air noise: plug the silencer into the free air discharge connection (see “Fig. 17: Pneumatic connection”) If used in an aggressive environment, we recommend conveying all free pneumatic connections into a neutral atmosphere with the aid of a pneumatic hose. The operation of the diaphragm control valve Type 2730, 2731 and 2731 K is possible only in combination with an control unit. Upper pilot air port Possible control units are: Positioner Type 8635, 8692, 8694, 8792 Process controller Type 8693, 8793 20 Lower pilot air port Observe the type label. Fig. 17: Pneumatic connection The pneumatic connection of the control unit is described in the respective operating instructions for the control unit. Control air hose: english Control air hoses of sizes 6/4 mm or 1/4“ can be used. Type 2730, 2731 and 2731 K Removal 8 Removal DANGER! 9 Electrical control unit The valve Type 2730, 2731 and 2731K can be combined with following control units: Risk of injury from discharge of medium and pressure. • Type 8635 It is dangerous to remove a device which is under pressure due to the sudden release of pressure or discharge of medium. ▶▶ Before removing a device, switch off the pressure and vent the lines. • Type 8692Positioner TopControl →→Loosen the pneumatic connection. →→Remove the device. Note! Positioner SideControl • Type 8694Positioner TopControl Basic • Type 8792 Positioner SideControl • Type 8693 Process controller TopControl • Type 8793 Process controller SideControl The electrical connection of the control unit is described in the respective operating instructions for the control unit. Deformation of the diaphragm. ▶▶ For prolonged storage of the valves, slacken the housing screws. english 21 Type 2730, 2731 and 2731 K Malfunctions 10 11 Malfunctions DANGER! Malfunction Cause /remedial action Actuator does not switch Pilot air port interchanged 4) CFA: Connecting lower pilot air port CFB: Connecting upper pilot air port Pilot pressure too low See pressure specifications on the type label. Medium pressure too high See pressure specifications on the type label. Valve is not sealed Medium pressure too high See pressure specifications on the type label. Pilot pressure too low See pressure specifications on the type label. Flow rate reduced PTFE diaphragm bulging →→Replace diaphragm. Tab. 11: Malfunctions Maintenance Danger – high pressure in the equipment. ▶▶ Before loosening the lines and valves, turn off the pressure and vent the lines. Risk of injury due to electrical shock. ▶▶ Before reaching into the system, switch off the power supply and secure to prevent reactivation! ▶▶ Observe applicable accident prevention and safety regulations for electrical equipment! Warning! Risk of injury from improper maintenance. ▶▶ Installation may be carried out by authorized technicians only and with the appropriate tools! Risk of injury from unintentional activation of the system and an uncontrolled restart. ▶▶ Secure system from unintentional activation. ▶▶ Following maintenance, ensure a controlled restart. 11.1 Maintenance and cleaning 11.1.1 Actuator 4) see “Fig. 17: Pneumatic connection” 22 english The actuator of the diaphragm control valve is maintenance-free provided it is used according to these operating instructions. Type 2730, 2731 and 2731 K Maintenance 11.1.2 Wearing parts of the diaphragm control valve 11.1.4 Service life of the diaphragm Parts which are subject to natural wear: • Diaphragm material • Seals • Medium, medium pressure, medium temperature • Diaphragm • Actuator size →→If leaks occur, replace the particular wearing part with an appropriate spare part (see chapter “12 Replacement parts”). A bulging PTFE diaphragm may reduce the flow. The replacing of the wearing parts is described in chapter “11.2”. The service life of the diaphragm depends on the following factors: • Pilot pressure for CFB. Protecting the diaphragm →→For CFA match the actuator size (actuator force) to the medium pressure to be actuated. If required, select the actuator with reduced spring force EC04. →→For CFB try and select the pilot pressure not higher than is required to actuate the medium pressure. 11.1.3 Inspection intervals 11.1.5 Cleaning The following maintenance work is required for the diaphragm valve: Commercially available cleaning agents can be used to clean the outside. →→After the first steam sterilization or when required retighten body screws crosswise. →→After maximum 105 switching cycles check the diaphragm for wear. Muddy and abrasive media require correspondingly shorter inspection intervals! Note! Avoid causing damage with cleaning agents. ▶▶ Before cleaning, check that the cleaning agents are compatible with the body materials and seals. english 23 Type 2730, 2731 and 2731 K Maintenance 11.2 Replacing the diaphragm DANGER! It is dangerous to remove a device which is under pressure due to the sudden release of pressure or discharge of medium. ▶▶ Before removing a device, switch off the pressure and vent the lines. 20 25 40 50 Notice! Damage to the diaphragm or the seat contour! ▶▶ When removing the actuator, ensure that the valve is in open position. →→Pressurize lower pilot air port of the actuator with compressed air (5 bar): valve opens. Fastening types 15 →→Clamp the valve body in a holding device (applies only to valves not yet installed). Risk of injury from discharge of medium and pressure. Orifice (Diaphragm size) [mm] Replacement for control function A Fastening types for diaphragms PTFE EPDM / FKM Diaphragm with bayonet catch Diaphragm with bayonet catch Diaphragm with bayonet catch Diaphragm screwed in Tab. 12: Fastening types for diaphragms →→Loosen the four body screws. →→Remove the actuator from the body. →→Unbutton or unscrew old diaphragm. If attachment is with a bayonet catch, remove the diaphragm by rotating it through 90°. For orifice DN25-DN50 observe chapter “11.2.1”. →→Install new diaphragm. →→Align diaphragm. The marker flap of the diaphragm must be perpendicular to the direction of flow (see “Fig. 18”)! →→Place actuator back on the body. →→Insert the body screws and lightly cross-tighten until the diaphragm is between the body and actuator. Do not tighten the screws yet. →→Actuate the diaphragm control valve twice. →→Without pressurization tighten the body screws to the per- mitted tightening torque (see “Tab. 13: Tightening torques for diaphragms”). 24 english Type 2730, 2731 and 2731 K Maintenance →→Place actuator back on the body. →→Lightly cross-tighten the body screws without pressurization until Marker flap of the diaphragm Actuator Upper pilot air port Lower pilot air port Diaphragm Body screws (4x) Valve body Fig. 18: Repairs Replacement for control functions B →→Clamp the valve body in a holding device (applies only to valves not yet installed). →→Loosen the four body screws. →→Remove the actuator from the body. →→Unbutton or unscrew old diaphragm. If attachment is with a bayonet catch, remove the diaphragm by rotating it through 90°. For orifice DN25-DN50 observe chapter “11.2.1”. the diaphragm is between the body and actuator. Do not tighten screws yet. →→Pressurize upper pilot air port of the actuator with compressed air (5 bar) (see “Fig. 18”). →→Actuate the diaphragm control valve twice. →→With pressurization tighten the body screws to the per- mitted tightening torque (see “Tab. 13: Tightening torques for diaphragms”). Orifice DN (diaphragm size) Tightening torques for diaphragms [Nm] EPDM PTFE 15 3.5 4 20 4 4.5 25 5 6 32 6 8 40 8 10 50 12 Tab. 13: Tightening torques for diaphragms 15 →→Install new diaphragm. →→Align diaphragm. The marker flap of the diaphragm must be perpendicular to the direction of flow (see “Fig. 18”). english 25 Type 2730, 2731 and 2731 K Replacement parts 11.2.1 Switch between PTFE and EPDM diaphragms Orifice DN15 and DN20: 12 Replacement parts Caution! →→Loosen PTFE diaphragm bayonet and attach new EPDM diaphragm. Risk of injury and/or damage by the use of incorrect parts. Orifice DN25 up to DN50: Incorrect accessories and unsuitable replacement parts may cause injuries and damage the device and the surrounding area. ▶▶ Use only original accessories and original replacement parts from Bürkert. →→Loosen PTFE diaphragm bayonet. →→Place the insert in the pressure piece. →→Insert and screw in EPDM diaphragm. The diaphragm is available as a replacement part for the piston-controlled diaphragm control valve Type 2730, 2731 and 2731K. If you have any queries, please contact your Bürkert sales office. Diaphragm Fig. 19: Diaphragm replacement part 26 english Type 2730, 2731 and 2731 K Replacement parts 12.1 Order table Orifice (Diaphragm size) [mm] Order numbers for diaphragms EPDM (AB*) EPDM (AD*) FKM (FF*) 15 677 664 E02** 688 422 E03** 677 685 F01** 15 BC** 693 162 E02** 693 163 E03** 693 164 F01** 32 677 678 E02PTFE** 679 544 E02PTFE+ Hole** – 40 677 679 E02PTFE** 679 545 E02PTFE+ Hole** 677 698 L01** 50 677 680 E02PTFE** 679 546 E02PTFE+ Hole** 677 699 L01** 20 677 665 E02** 688 423 E03** 677 686 F01** 20 BC** 693 165 E02** 693 166 E03** 693 167 F01** 25 677 667 E01** 688 424 E03** 677 687 F01** * SAP Code 32 677 668 E01** 688 425 E03** 677 688 F01** ** Identification on the diaphragm 40 677 669 E01** 688 426 E03** 677 689 F01** 50 677 670 E01** 688 427 E03** 677 690 F01** PTFE (EA*) Advanced PTFE (EU*) Laminated advanced PTFE (ET*) 15 677 675 E02PTFE** 679 541 E02PTFE+ Hole** 677 695 L02** 20 677 676 E02PTFE** 679 542 E02PTFE+ Hole** 677 696 L02** 25 677 677 E02PTFE** 679 543 E02PTFE+ Hole** 677 697 L01** Tab. 14: Order numbers for diaphragms english 27 Type 2730, 2731 and 2731 K Packaging, transport, storage 13 Packaging, transport, storage Note! Transport damages. Inadequately protected equipment may be damaged during transport. • During transportation protect the device against wet and dirt in shock-resistant packaging. • Avoid exceeding or dropping below the permitted storage temperature. Incorrect storage may damage the device. • Store the device in a dry and dust-free location. • Storage temperature -20 – +65 °C. Damage to the environment caused by device components contaminated with media. • Dispose of the device and packaging in an environmentally friendly manner. • Observe applicable regulations on disposal and the environment. Note: Observe national waste disposal regulations. 28 english www.burkert.com ">
/
Изтегляне
Само приятелско напомняне. Можете да видите документа точно тук. Но най-важното е, че нашият AI вече го е прочел. Той може да обясни сложни неща с прости думи, да отговори на вашите въпроси на всеки език и да ви помогне бързо да навигирате дори в най-дългите или сложни документи.
Реклама