R F M 8 0 0 R e f r a c t o m e t e r s

Refractometers with Peltier

Temperature Control for Laboratory

Applications

• Laboratory Automation

• Pharmaceutical

• Chemical

• Petrochemical

• Flavours

• Fragrance

• Essential Oils

• Edible Oils

• Mineral Oils

• Research

B e l l i n g h a m + S t a n l e y L t d .

Q u a l i t y S c i e n t i f i c I n s t r u m e n t s

RFM800

A u t o m a t i c D i g i t a l R e f r a c t o m e t e r s f o r t h e 21 s t C e n t u r y

For over 90-years Bellingham + Stanley has been at the forefront of refractometer design and the RFM trademark has become synonymous for setting the standards in precision, quality and reliability. Whilst these standards are now taken for granted, the

RFM800 series represents a major advance in measurement technology allowing digital refractometers to be placed in principal laboratories the world over.

The RFM800 series comprises four standard models that allow the user to select the instrument that best suits the particular application and regulatory requirements. Whilst all instruments incorporate common manufacturing components and software design, models vary according to measuring range, resolution and accuracy.

Measurement Features:

RFM800 series refractometers offer one of the highest measurement specifications available. Results may be displayed in refractive index or Brix, or alternatively, over 15 industry standard scales may be loaded from the instrument library without the need for expensive

‘plug-in cards’. Customer defined scales may also be created by using software available free of charge from the Internet.

Sample containment is vital in providing a rapid temperature response. A carefully shaped prism dish ensures only the right amount of sample is applied to the sapphire prism and closecontact temperature sensors ensure rapid response from Peltier devices to quickly control the sample temperature. Readings are monitored by software and when in ‘SMART temperature stability mode’, the result is displayed only when both reading and temperature has stabilised. ICUMSA temperature compensation is also provided with the option to load User

Temperature Compensation.

A carefully shaped prism dish controls precious sample volume and gives rapid temperature stability when samples are applied with a differing temperature to that of the instrument.

Cleaning requires less solvent with less interruption to temperature regulation.

Software Features:

A powerful microprocessor lies behind a simple control panel providing standard measurement or industry specific methods.

Navigation is by cursor or numeric index and access is protected to three levels depending on the security of measurement required.

The reading display can be configured to show one or a number of different measurement parameters along with instrument configuration, batch code and operator identifiers in accordance with GLP and the technical requirements of FDA regulation CFR21

Part 11. A ‘Methods system’ provides instant selection of measurement configuration (scale/TC/temperature etc.) and offers a check against predetermined reading limits. Readings may be output to a printer and/or sent to LIMS in CSV format.

Automation:

RFM800 series refractometers provide both mechanical and electrical connection to other instruments and automated systems.

Beer analysis in accordance with International Standards is made easy by connecting a compatible density meter, with alcohol & gravity results being calculated and output in the normal way. A micro flowcell provides the connection for pumped sample from an autosampler in beer and fragrance & flavours systems, whilst funnel flowcells give rapid readings in busy sugar laboratories. Full details of automated systems are available on request.

One, Two and Multipoint Calibration:

Two-point calibration in any selected scale allows accurate control of measurement. Typically ‘zero calibration’ is made with air and water but for narrow range or high temperature measurement, other samples such as oils may be used. Span calibration facilitates control at the upper end of the scale, whilst multipoint calibration is available to customers wishing to make minor adjustments at more than one point.

Uniquely, a wide selection of calibration materials traceable to

International Standards* is available from Bellingham + Stanley Ltd.

Robust Manufacture:

Construction materials have been carefully selected to withstand common samples and solvents. The chemical resistant

Polyurethane Foam case offers a seal against moisture and corrosion, whilst materials in contact with the prism are of the highest specification including Kalrez® gaskets and PEEK spill barriers as standard. Optional ‘splash covers’ are also available. The temperature control system comprises internal Peltier elements and heatsinks using a system of controlled airflow through filtered ducting to ensure there is no contamination to the optics, electronics or heatsinks; ensuring performance year after year.

* For details contact B+S Ltd or recognised distributor

Prism

Measurement display showing detailed reading

SMART stability check temperature screen

Computer simulated images

Security Features:

FDA Regulation CFR21 Part 11

Strict controls within the pharmaceutical industry dictate the need for high levels of security in terms of sample analysis and data control. Instrument software facilitates the level of security: low, medium and high. The lowest level requires a 3digit PIN to access determinable parts of the instrument menu, whilst ‘medium’ requires an 8-digit PIN. In either of these modes, setting the supervisor PIN to zero allows free access to all users.

The highest standard of security is compliant with the technical requirements of FDA regulation CFR21 Part 11, where access to measurement and data transfer is strictly controlled, making use of extended passwords and electronic signatures that have a controlled schedule of validity and re-usage. Changes to the instrument configuration are also recorded in the instrument as an ‘audit trail’ that also records calibration activity, all of which may be extracted using PC software.

Additionally, latest models are fitted with a non-volatile memory that if activated, will record instrument configuration and electronic signatures, so that in the unlikely event of instrument failure, installation of new equipment is made easy and audit trails remain intact.

Method set-up screen Security setting screen

Measurement Features:

• Wide Range – 1.30 to 1.70 RI

• Standard Brix range

• User Scale Library

• 5-decimal place RI

• 2-decimal place Brix

• Peltier Temperature Control

• Wide Temperature Range

Software Features:

• Temperature Stability Checks

• Measurement Methods

• Reading Limits Check

• Calibration Log/Report

• PIN Protection

• GLP Printout

• CFR21 Part 11

Methods:

• Coffee

• BeerSmart %ABV

• Daily Offsets

• Edible Oils

• Automation

Options:

• Funnel Flowcell

• Micro Flowcell

• Barcode Reader

• Autosampler

• IP66 Power Supply

• Calibration Materials

• Splash Covers

Compliance:

• GLP

• OIML

• USP/EP/BP

• ASTM D 1218-02

• ASTM D 5006

Measurement Specifications

Scales

RI

Sugar (°Brix)

User-defined (100 scales – configurable)

Resolution

RI

Sugar (°Brix)

Accuracy

RI

Sugar (°Brix)

Presser Type

Other Scales

Reading Time

Ambient Temperature Range

Measuring Temperature Range

Lower limit

Upper limit

Temperature Sensor Accuracy

Temperature Stability

Automatic Temperature Compensation

Sucrose (°Brix)

User-defined

Temperature Stability Checks

Ambient Humidity Range

RFM830

1.32 – 1.58

0-100

YES

RFM840

1.32 – 1.58

0-100

YES

RFM860

1.30 – 1.70

0-100

YES

RFM870

1.30 – 1.70

0-100

YES

0.0001

0.1

0.00001

0.01

0.0001

0.1

0.00001

0.01

±0.0001

±0.1

±0.00002

±0.02

±0.0001

±0.1

±0.00002

±0.02

Polyacetyl Polyacetyl PEEK PEEK

Zeiss, Oechsle (CH) & (D), Babo (KMW), Baumé, Probable Alcohol

(A.P.), Sodium Chloride (NaCl), HFCS (42, 55 & 90%), Butyro amongst others from instrument library OR custom user scales by push button entry or via PC program

Minimum 4 seconds

0 – 40 °C

0 °C or 10 °C below ambient whichever is the greater approximately 100 °C

± 0.03 °C

± 0.05 °C

5 – 80 °C

Simple coefficient (units/ °C) or polynomial function with offset

None/delay time/repeatability/Smart

(independently selectable by method)

< 80% RH

Bellingham+Stanley Ltd operates a Quality Management

System complying with BS EN

ISO 9001:2000 (Certificate No.

LRQ 0963791).

Bellingham+Stanley Ltd pursues a policy of continuous product development and improvement, and, as such, information given on this

Data Sheet may be updated or withdrawn without notice.

These products comply with the requirements of the

Low Voltage Directive 73/23/EEC and the EMC

Directive 89/336/EEC

Physical Specifications

Prism

Prism Dish

Prism Seal

Interfaces

Sample Illumination

Temperature Control

Artificial Sapphire

316 Stainless Steel / PEEK

Kalrez®

1 Parallel (printer), 2 x Serial (RS232)

Light Emitting Diode – (life 100,000 hours +)

Peltier

55-80

55-81

26-292

26-155

55-250

26-80

26-81

28-82

26-451

Warranty

Order Codes Description

26-30

26-40

26-60

26-70

RFM830 including external power supply (100-240V~, 50-60Hz), spare filters (4 Pack) and instructions

RFM840 including external power supply (100-240V~, 50-60Hz), spare filters (4 Pack) and instructions

RFM860 including external power supply (100-240V~, 50-60Hz), spare filters (4 Pack) and instructions

RFM870 including external power supply (100-240V~, 50-60Hz), spare filters (4 Pack) and instructions

Barcode Reader (230V~, 50Hz)

Barcode Reader (110V~, 60Hz)

Dust Filter (Pack of 20)

Switch Membrane Anti-splash Cover

Waterproof Power Supply to IP66 (100-240V~, 50-60Hz)

Micro Flowcell (vol. 0.6ml)

Macro Flowcell (vol. 1.2ml)

Funnel Flowcell (vol. 1.2ml & 30ml flush at 30 °Brix max.)

Validation Documentation (only)

24-months

B e l l i n g h a m + S t a n l e y L t d .

Longfield Road, Tunbridge Wells, Kent TN2 3EY, United Kingdom.

Phone: +44 (0) 1892 500400. Fax: +44 (0) 1892 543115. www.bellinghamandstanley.com [email protected]

Bellingham+Stanley Inc., 1000 Hurricane Shoals Road, Building D, Suite 300, Lawrenceville, GA 30043 USA

Phone: 770 822 6898. Fax: 770 822 9165. www.bellinghamandstanley.com [email protected]

1302/0406