714 English Instruction Sheet
Page 1
99 Washington Street
Melrose, MA 02176
800.517.8431
TestEquipmentDepot.com
714
Thermocouple Calibrator
®
Instruction Sheet
Introduction
The Fluke 714 Thermocouple Calibrator is a precise source and measurement tool for calibrating thermocouple instruments. The calibrator sources or measures in units of ° C, ° F, or mV, through a thermocouple minijack.
Your calibrator is supplied with a Flex-Stand holster, an installed 9 V alkaline battery, and this instruction sheet. Sets of thermocouple miniplugs are available from Fluke. (Accessories
Fluke-700TC1 and Fluke-700TC2 TC Miniplug Kits.)
If the calibrator is damaged or something is missing, contact the place of purchase immediately. Contact your Fluke distributor for information about accessories. To order replacement parts or spares, see “Replacement Parts.”
The following tables list the thermocouple types supported by the calibrator, the standards and scales used for each type, the thermocouple properties, and calibrator resolution. Full calibrator specifications are listed at the end of this instruction sheet.
Note
Since mV input and output units are available, you can use the calibrator for any thermocouple type by making manual calculations or referring to tables.
PN 650306 July 1997 Rev. 1, 10/97
1997 Fluke Corporation. All rights reserved. Printed in U.S.A.
All product names are trademarks of their respective companies.
714 English Instruction Sheet
Page 2
Thermocouple Standards and Scales
Thermocouple Type Standard
J, K, T, E, R, S, B
L (J-DIN), U (T-DIN)
NIST 175
DIN 43710
Scale
ITS-90
IPTS-68
Thermocouple
Type
J
K
T
E
R
S
B
L
U
Thermocouple Properties
Temperature
Ranges
Display Resolution
0.1
° C or ° F -200 to 1200 ° C,
-328 to 2192 ° F
-200 to 1370
°
C
-328 to 2498 ° F
-200 to 400 ° C
-328 to 752 ° F
-200 to 950 ° C
-328 to 1742 ° F
-20 to 1750 ° C
-4 to 3182 ° F
-20 to 1750 ° C
-4 to 3182 ° F
600 to 1800 ° C
1112 to 3272 ° F
-200 to 900 ° C
-328 to 1652 ° F
0.1
0.1
0.1
1
1
1
°
°
°
C or
C or
C or
0.1
°
°
°
°
C or
C or
C or
°
°
°
F
F
F
C or
°
°
°
°
F
F
F
F
-200 to 600 ° C
-328 to 1112
°
F
0.1
° C or ° F
714 English Instruction Sheet
Page 3
Mode
mV
Millivolt Range and Resolution
Range Display Resolution
-10 to 75 mV 0.01 mV
Explanation of International Symbols
The following symbols are used on the calibrator or in this instruction sheet. The table below explains their meaning.
Symbol
J
I
M
W
T
International Symbols
Meaning
Earth ground
Fuse
Battery
Refer to this instruction sheet for information about this feature.
Double insulated
P
Conforms to relevant Canadian Standards
Association directives.
Conforms to European Union directives
714 English Instruction Sheet
Page 4
Safety Information
W
Warning
To avoid possible electric shock or personal injury:
•
Never apply more than 30 V between the TC terminals, or between either TC terminal and earth ground.
•
Make sure the battery door is closed and latched before you operate the calibrator.
•
Remove an attached thermocouple miniplug from the calibrator before you open the battery door.
•
Do not operate the calibrator if it is damaged.
•
Do not operate the calibrator around explosive gas, vapor, or dust.
When servicing the calibrator, use only specified replacement parts.
Turning the Calibrator On
Press the green
O
pushbutton to turn the calibrator on and off.
714 English Instruction Sheet
Page 5
Measuring a Thermocouple
INPUT
Shows TC type selected
714
Press to select
TC type or mV
Press to toggle
°
C or
°
F
Press so that
INPUT is on the display
30V
MAX
TC
TC wire and miniplug of same type as selected ke01f.eps
714 English Instruction Sheet
Page 6
Simulating a Thermocouple
OUTPUT
Shows TC type selected
714
Press to select
TC type or mV
Press so that
OUTPUT is on the display
Press to toggle
°
C or
°
F
Press to step up/down 50 °
(or 10 mV)
30V
MAX
TC
Press to scroll up/down 0.1
°
(or 0.01 mV).
Hold down to scroll faster
TC wire and miniplug of same type as selected ke02f.eps
714 English Instruction Sheet
Page 7
Maintenance
For maintenance procedures not described in this sheet, contact a Fluke Service Center.
In Case of Difficulty
• Check the battery and thermocouple test wiring. Replace as necessary.
• Review this sheet to make sure you are using the calibrator correctly.
If the calibrator needs repair, contact a Fluke Service Center. If the calibrator is under warranty, see the warranty statement for terms. If the warranty has lapsed, the calibrator will be repaired and returned for a fixed fee. Contact a Fluke Service Center for information and price.
Cleaning
Periodically wipe the case with a damp cloth and detergent; do not use abrasives or solvents.
Calibration
Calibrate your calibrator once a year to ensure that it performs according to its specifications. A calibration manual is available
(PN 686540). Call 1-800-526-4731 from the USA and Canada. In other countries, contact a Fluke Service Center.
Replacing the Battery
When the M symbol appears on the display, replace the battery with a 9 V alkaline battery.
714 English Instruction Sheet
Page 8
Replacing the Fuse
!
Warning
To avoid personal injury or damage to the calibrator, use only a 0.125A 250V fast fuse,
Littelfuse ® 2AG.
Fuse F1 is probably blown if in the input mode, the calibrator always reads OL, even with a thermocouple connected.
it07f.eps
714 English Instruction Sheet
Page 9
Replace the fuse as follows:
1. Remove the test leads and turn the calibrator off.
2. Remove the battery door.
3. Remove the three Phillips-head screws from the case bottom and turn the case over.
4. Gently lift the top cover from the end nearest the input/output terminals until it unsnaps from the bottom cover.
5. Replace the fuse with a 0.125 A 250 V fast fuse, Littelfuse
2AG.
®
6. Fit the top and bottom covers together, engaging the two snaps. Make sure that the gasket is properly seated.
Reinstall the three screws.
7. Replace the battery door.
714 English Instruction Sheet
Page 10
F1
Snaps ke03f.eps
714 English Instruction Sheet
Page 11
Replacement Parts and Accessories
Replacement Parts
Item Description PN or
Model no.
BT1 614487
CG81Y
!
F1
MP85
MP86
9V battery, ANSI/NEDA 1604A or
IEC 6LR61
Holster, Yellow
Fuse, 125 mA, 250V fast
Case top
Case bottom
1
CG81Y 1
686527 1
620234
620168
1
1
Qty.
S1
−
−
H2, 3, 4 Case screw
MP89, 90 Non-skid foot
MP92
H5, 6
Battery door
Battery door fasteners
Keypad
714 Instruction Sheet
71X Series Calibration Manual
832246
824466
619947 1
948609 2
3
2
687076 1
560306 1
686540 Option
714 English Instruction Sheet
Page 12
MP85
BT1
MP86
H2, 3, 4
H5, 6
F1
Instruction
Sheet
Holster
MP92
S1
MP89, 90 ke04c.eps
714 English Instruction Sheet
Page 13
Specifications
Specifications are based on a one year calibration cycle and apply for ambient temperature from +18 ° C to +28 ° C unless stated otherwise. “Counts” means number of increments or decrements of the least significant digit.
Temperature Measure and Thermocouple Simulate
TC Type Resolution
J, K, T, E, L, U 0.1
° C or ° F
B, R, S 1 ° C or ° F
Maximum input voltage: 30 V
-10 mV to 75 mV
Maximum input voltage: 30 V
0.01 mV
Error
± (0.3
° C + 10 µ V)
± (0.3
° C + 10 µ V)
Millivolt Measure and Source
Range Resolution
Reference
Junction
Error
± 0.2
° C
± 0.2
° C
Accuracy
± (0.025% + 1 count)
714 English Instruction Sheet
Page 14
General Specifications
Maximum voltage applied between any terminal and earth ground or between any two terminals:
30 V
Storage temperature:
-40 ° C to 60 ° C
Operating temperature:
-10 ° C to 55 ° C
Operating altitude:
3000 meters maximum
Temperature coefficient:
0.05 x specified accuracy per ° C for temperature ranges -10 ° C to 18 ° C and 28 ° C to 55 ° C
Relative humidity:
95% up to 30 ° C, 75% up to 40 ° C, 45% up to
50 ° C, and 35% up to 55 ° C
Vibration:
Random 2 g, 5 Hz to 500 Hz
Shock:
1 meter drop test
Safety:
Certified as compliant to CAN/CSA C22.2 No.
1010.1:1992. Complies with ANSI/ISA S82.01-1994.
Power requirements:
Single 9 V battery (ANSI/NEDA 1604A or
IEC 6LR61)
Size:
32 mm H x 87 mm W x 187 mm L (1.25 in H x 3.41 in W x
7.35 in L);
With holster and Flex-Stand: 52 mm H x 98 mm W x 201 mm L
(2.06 in H x 3.86 in W x 7.93 in L)
Weight:
332 g (11.7 oz);
With holster and Flex-Stand: 584 g (20.6 oz)
714 English Instruction Sheet
Page 15
LIMITED WARRANTY & LIMITATION OF LIABILITY
This Fluke product will be free from defects in material and workmanship for three years from the date of purchase. This warranty does not cover fuses, disposable batteries or damage from accident, neglect, misuse or abnormal conditions of operation or handling. Resellers are not authorized to extend any other warranty on Fluke’s behalf. To obtain service during the warranty period, send your defective calibrator to the nearest Fluke Authorized Service Center with a description of the problem.
THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER
WARRANTIES, SUCH AS FITNESS FOR A PARTICULAR PURPOSE,
ARE EXPRESSED OR IMPLIED. FLUKE IS NOT LIABLE FOR ANY
SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES
OR LOSSES, ARISING FROM ANY CAUSE OR THEORY. Since some states or countries do not allow the exclusion or limitation of an implied warranty or of incidental or consequential damages, this limitation of liability may not apply to you.