Yokogawa AF220 Flash Microprocessor Programmer Instruction Manual
Oglas
Oglas
NET IMPRESS
Network Compatible in-circuit Flash Micom Programmer for Enbedded Smart Systems
FLASH MICOM PROGRAMMER
Instruction Manual
Yokogawa Digital Computer Corporation
Contents
1. Overview and Features ...............................................................................................8
Part Names and Functions ...............................................................................................11
4. Using the AF220.......................................................................................................14
4.1 Installation.................................................................................................................................... 14
4.4 Programming................................................................................................................................ 23
5. List of Commands ....................................................................................................26
5.1 Functions List............................................................................................................................... 26
5.3.1 Edit (Buffer RAM Content Modifications) ....................................................................... 33
5.3.3 Buffer Clear (Buffer RAM Initialization).......................................................................... 36
5.3.4 Modified Bit Search (Modified Data Search).................................................................... 37
5.3.6 YSM File Check (Function 98) ......................................................................................... 39
5.4 Parameter Settings........................................................................................................................ 40
5.4.3 UART Baud Rate Setting (Function D2)........................................................................... 43
5.4.4 CSI Baud Rate Setting (Function D9) ............................................................................... 44
5.4.5 TVcc Threshold Setting (Function D3) ............................................................................. 45
5.4.10 Displayed Model Name Change (Function D8) ................................................................ 50
5.4.13 MCU Operating Frequency Setting (Function DF) ........................................................... 53
5.4.17 Beep Tone Setting (Function 95)....................................................................................... 57
5.5 Ethernet Settings .......................................................................................................................... 60
5.5.2 IP Address/Port Setting (Function E2) .............................................................................. 61
5.6 List of Device Functions .............................................................................................................. 63
5.6.1 Copy .................................................................................................................................. 64
2
5.6.3 Erase .................................................................................................................................. 66
5.6.4 Program ............................................................................................................................. 67
5.6.6 E.P.R. ................................................................................................................................ 69
6. One Action Key Function.........................................................................................70
6.2.1 Command Sequence File (*.CSB)..................................................................................... 71
6.2.2 Command Sequence File Format ...................................................................................... 71
8. Specifications ...........................................................................................................76
8.1 Operating Conditions ................................................................................................................... 76
8.2.1 Connector (RS-232C)........................................................................................................ 77
8.3 Ethernet Interface ......................................................................................................................... 80
8.3.1 Connector (Ethernet) ......................................................................................................... 80
8.3.2 Signal Table....................................................................................................................... 80
8.4.2 Signal Table....................................................................................................................... 81
8.5.1 Connector (EXT.KEY)...................................................................................................... 82
8.5.2 Signal Table....................................................................................................................... 82
8.6.1 Connector (TARGET PROBE) ......................................................................................... 84
9.1 Maintenance Service Contract Recommendation......................................................................... 88
9.2 Maintenance Service .................................................................................................................... 89
9.3.1 Purpose .............................................................................................................................. 90
9.3.2 Service Contents................................................................................................................ 90
9.3.3 Others ................................................................................................................................ 90
Appendix List of Error Codes ......................................................................................96
3
Instruction Manual
No. M2320KE-06
Revision History
Revision
Version 1
Version 2
Version 3
Version 4
Version 5
Publication Date
September 1, 1999
November 16,1999
June 12,2001
August 22,2001
June 25,2007
Details of Change
Initial Publication
Del. Appendix I and Appendix II
Correction of AZ211and AZ213 pin assign
Correspond to CE mark and
Correction of EXT.KEY pin assign
The information of the lead color change is added
Correction of One Action Key definitions Version 6 July 24,2007
Notices
(1) This manual may not be reproduced, neither in whole or in part, without permission.
(2) The contents of this manual are subjected to change without notice.
(3) Please contact YDC or your local distributors regarding any problems or suggestions.
(4) Regardless of (3), Yokogawa Digital Computer Corporation (YDC) accepts no liability for damages arose from the use of this product.
© 1999 Yokogawa Digital Computer Corporation. All rights reserved. Printed in Japan.
4
Ensuring Safety Use of Flash Writer
In order to ensure the proper and safety use of Flash Writer, please be sure to follow the safety caution mentioned below as operating Flash Writer. Yokogawa Digital Computer Corporation has no responsibility nor guarantee for any injuries which occur as a result of the violation of these safety caution and warnings.
♦
Following safety-related symbols are used on Flash Writer and its instruction manual for a safety use.
It indicates not only that there is a danger to humans as well as to the equipment, but also that it is necessary to refer to the instruction manual.
It indicates a safety ground terminal. As this terminal is on the main unit, please be sure to connect this terminal to the ground before operating.
Warning!
In order to avoid the risk of death or serious injury which may occur as a result of an incorrect use.
Caution!
In order to avoid the risk of minor injury or material damage which may occur as a result of an incorrect use.
♦
To avoid the risk of death or serious injury to users, such as electrocution or any other accidents, as well as the risk of damage to Flash Writer, please follow the warnings mentioned below.
•
Warning!
Use in Chemical Gases
Do not use Flash Writer in an environment where are combustible or explosive gases or steam.
Using Flash Writer in such environment is extremely dangerous.
•
Power Supply
As Flash Writer is designed to prevent the electrocution or any other accidents, be sure to use the power supply pack (AC adapter) specified by Yokogawa Digital Computer Corporation ONLY.
The power supply pack is designated as an option with /AC4P.
Confirm that the supply-side voltage matches to the rated power supply voltage for a power supply pack. Also ensure that the power supply switch (on the back panel) of Flash Writer is switched "OFF" before connecting to the power cord.
•
Removing the Case
Only qualified service engineers should remove the case of Flash Writer because of the high voltage.
5
Making the Most of Flash Writer
The Flash Writer is an electronic device which consists of high-precision electronic components. Please be sure to understand and follow the caution listed below in order to avoid any accidents and as well as to make the most of your Flash Writer.
1. Switch ON / Switch OFF Sequence
Warning!
•
Refer to the Switch ON / Switch OFF sequence below regarding Switch ON and OFF of the host computer, Flash Writer, and the target system.
•
The Switch ON / Switch OFF sequence should be followed in order to avoid major damages to the target system and Flash Writer itself. (especially between Flash Writer and the target system.)
<Power Up Sequence>
<Power Down Sequence>
computer
2. Connecting the Probe and Connector
Warning!
•
Switch OFF the power supply of Flash Writer and the target system before plugging in or unplugging any probes or cables.
•
All probes and cables are designed to prevent an incorrect connection. Never force them to plug in nor unplug. Confirm the position and direction.
3. Disassembling Flash Writer
Warning!
•
Since Flash Writer contains printed circuit boards with minute patterns, never remove screws or disassemble Flash Writer.
6
IMPORTANT
Flash Writer
To make the most of Flash Writer, please read and understand AF200 Flash Writer Instruction Manual before use. After reading the instruction manual, please keep it for the further reference whenever required.
Please ensure that Flash Writer should be used only by persons who have read and understood the instruction manual. We strongly recommend that the first-time users receive an proper instruction from those who have a good knowledge of Flash Writer.
What is Flash Writer?
The Flash Writer is AF200, Flash Writer main unit, control modules, and other related products manufactured by Yokogawa Digital Computer Corporation. The target system and the host computer are strictly excluded.
Flash Writer is an electronic device which consists of the high-precision electronic components. In order to make the most of Flash Writer and also to prevent any accidents, please follow the caution listed below.
A certain repair fee is required regarding the equipment damages resulted from an incorrect use or connection, etc. Please aware that it may require a few months for repairs.
Regarding software products and manuals, YDC guarantees only if there are any damages of media provided by Yokogawa Digital Corporation, manual defects or trouble executing the program installation.
If proved that there are bugs or that there are problems apart from those listed above, the action will be taken based on the maintenance agreement.
•
Caution!
Be sure to Switch OFF the power supply of Flash Writer and the target system before plugging in or unplugging any cables between Flash Writer and the target system. Be aware that plugging in or unplugging any cables while the power supply is ON, may result in an explosion or ignition of Flash Writer or the target system.
•
Before Switching ON the power supply, be sure to confirm whether the direction of Pin 1 in the probe tip matches to Pin 1 Socket in the target system. An incorrect connection may result in an explosion or ignition of Flash Writer or the target system.
Warning!
•
As particular parts of electronic circuits in the probe tip are exposed, Flash Writer should be used only in environments where are protected from a static electricity. Using Flash
Writer in such environment as without static electric protection, may result in destroying
Flash Writer or the target system.
•
The Switch ON / OFF sequence should be followed. Flash Writer should be switched ON prior to the target system and remained ON while Switch ON / OFF of the target system power supply. An incorrect Switch ON / OFF sequence may result in a serious damage to
Flash Writer or the target system circuits.
7
1. Overview and Features
The AF220 is a flash microprocessor programmer for programming microprocessors with embedded flash ROMs. Through using the microprocessor-specific control modules (optional
PC cards) the AF220 can support programming specifications for different types of microprocessors with embedded flash ROMs. The AF220 model offers more enhancements and higher speeds than the legacy AF200 model and supports Ethernet (10 BASE-T). As the
AF220 has forward compatibility with the AF200 models, all of the control modules used with the AF200 can also be used with the AF220.
CAUTION!: The /ACP and /AC2P AC adapters and the AZ201 and AZ202 RS-232C cables used with the AF200 can not be used with the AF220. Use /AC3P or /AC4P AC adapters and
AZ221 or AZ222 RS-232C cables with the AF220.
Features
1. The AF220 can support the programming specifications for all types of microprocessors using the microprocessor-specific control modules (optional PC cards).
2. The user system can connect to the AF200 using microprocessor-specific target probes
(option). The target microprocessors can be programmed while they are mounted and soldered on the user system.
3. It can be used as a standalone. Programming information can be saved as a file in the
DOS area of the PC card.
4. Remote control from the host computer can be performed using an RS-232C interface.
This enables file transfer and programming parameter changes (optional AZ290 software is required).
5. As the AF220 can be connected using Ethernet it can be connected to a network and used to build a system. The AF220 can be easily used to remotely control application software created at customers' sites using remote control package AZ291 (optional software which uses Microsoft's COM). The user can upgrade the AF220 to handle automatic programming systems.
6. High speed flash memory programming.
7. High speed search for modified data.
8. Modification information can be saved on the PC cards in the form of modification files for the original programming information files.
8
CE Notes: ( only for AF221 series )
The CE mark on the back of this Yokogawa Digital Computer (YDC) product indicates that it conforms to the requirement of the EMC (Electromagnetic Compatibility) Directive of the European
Union (Directive 89/336/EEC). This YDC product has been tested to the following technical standards:
■ EN 55022 (1998) :
■ EN55024 (1998) :
- Conducted Emission test.
- Radiated Emission test.
- Power-frequency magnetic field.
- Radio-frequency electromagnetic field.
- Electrostatic discharge.
- Radio-frequency continuous conducted.
- Fast transients.
- Voltage dips and interruptions.
- Surges.
■ EN61000-3-2 (1995):
- AC Mains Harmonic Emissions.
■ EN61000-3-3 (1995):
-Voltage Fluctuations and Flicker.
The details of product’s compliance with the EMC Directive are contained in a Technical
Construction File (TCF) which is on file at Ashling Microsystems Ltd., National Technological Park,
Limerick, Ireland.
To ensure that your product can be used without causing interference to, or being affected by other electronic equipment, please note the following:
■ Before using this YDC product, please read this User Manual, and in particular those sections of the manual that describe how the product may be safety used; and that describe how to avoid static-discharge damage to this YDC product, or the system in which it is used.
■ This product is designed for use with a Personal Computer whose electromagnetic emission and susceptibility performance comply with the EMC Directive.(at the Remote Control Application.)
■ This YDC product contains high speed digital electronic circuits which are susceptible to electrostatic discharges. The user is advised that no part of the product or its enclosure should be subjected to an electrostatic discharge exceeding 2KV.
■ This YDC product contains an Target Probe that is designed to attach directly to digital logic voltages in the range 0-5V (except for Vpp voltage). Please note in particular that.
・The Target probe should be attached to a target system, with the programmer powered on, before powering up the target system.
・If you have selected a specific operation voltage (for example 3.3V) then no voltage in excess of this figure should be applied to the Target probe (unless the User Manual specifically states that a higher voltage is permissible in certain cases).
■ Due to the nature of the Flash Micro Programmer, the target system and the connections to the
Programmer having to be exposed and having no shielding, it is to be expected that this YDC product will not meet the Class A Radiated Emission requirements of EN 55022. To resolve this issue the User Instructions specify that Radio and Broadcast Receivers used within a 30m. radius of the Programmer are likely to experience interference from the Flash Micro Programmer. The choice of 30m. distance is based on the actual radiated emissions measured at 10m..
9
2. General Precautions
1. Only use AC adapters that Yokogawa Digital Computer (YDC) has approved. When you connect the DC jack to the AF220, make sure that the AC plug has been unplugged and the Power Switch has been turned off.
2. Do not use the AF220 in dusty areas, where there is direct sunlight, or where corrosive gas is generated.
3. Use the AF220 in an environment with a temperature between 5 and 40 ℃ and between
20 and 80% humidity.
4. If there is noise in the AC current line then use a noise filter to eliminate the noise.
5. Do not format the control modules (PC cards). The control modules contain the control programs for the flash writers as well as the DOS area for the user programs. Formatting the control modules will destroy the control programs.
6. Turn off the AF220 power switch before replacing the control modules.
7. The procedure for turning the power on is to turn the AF220 on first and the user system second. The power should be turned off in the reverse order.
8. The AF220 can be operated with the PC cards connected to the specified PC card connector. The AF220 can not be operated with the PC cards removed.
CAUTION:
Carelessness while using the AF220 can cause the definitions (card contents) to be destroyed.
YDC does offer a fee-based service to program the definitions. For more information contact us or one of our authorized distributors.
Visit our home page for information about how to use the AF220 and related products and for the latest information.
Flash writer home page: http://www.ydc.co.jp/micom/
10
3. Part Names and Functions
2. RS-232C Connector
1. Ethernet Connector
3. Model Name
4. LCD
5. Target Connector
7. EXT.KEY Connector
6. DC Power Jack
8. Keyboard
9. PC Card slot
11
10. Power Switch
1. Ethernet Connector
This is the connector to connect with an Ethernet. The AF220 comes equipped with it.
2. RS-232C Connector
This is a serial communications connector to connect with the host computer.
3. Model Name
This is the model name.
4. LCD
Displays all types of information.
Ⅰ
Ⅱ
Ⅲ
H V / F O 0 0 1 S 1 / B L A N K
F / M / 0 0 1 0 0 0 / A A / A A
Ⅳ Ⅴ
Ⅵ Ⅶ
Ⅷ
I. Programming Power Application Display
This shows that high voltage power for programming is being applied. This display can be reset by pushing the RESET key.
II. Control Module Model Name
Displays the model name of the control modules in the PC cards. How to customize this display part is described in Chapter 5.
III. Device Function Display
Displays the device function which is being executed.
IV. Function Display
Displays the function which is being executed.
V. Bit Modification Display
Displays that the buffer RAM data is modified. Displays "M" when the data is modified by key input or buffer transfer.
12
VI. Address Display
Displays the flash memory address, data key entry, and all types of messages. This only displays the lowest six address digits and does not display the higher address digits.
VII. Buffer
Displays buffer RAM data and error codes.
VIII. ROM Data/Checksum
Displays the flash ROM data and the buffer RAM data checksum values.
5. Target Connector
This is the connector to connect the target system and the probe.
6. DC Power Jack
This jack is to connect the AC adapter for the AF220.
7 EXT KEY Connector
This connector can be used to externally operate "DEV", "RESET", "SET", and two blank keys. Use the connection cable AZ223 (option).
8. Keyboard
0-F
Use 16 hexadecimal data keys to enter the numerical values. Additionally, 8, 9, C, D, E, and F can be used combined with the DEV key to specify all device functions.
RESET
Use this key to abort operations and to delete error messages. This can also cancel remote operations at the same time.
FUNC, DEV
These are the command keys which are combined with the 16 hexadecimal data keys for all operating settings.
▲ ▼
These are the keys to increment and decrement the address values. The buffer RAM and the
ROM data for the addresses are displayed simultaneously. You can use the FUNC key to enter parameter delimiters.
SET
Use this key to set the modes and to execute commands with the FUNC and DEV keys.
You can use the SET key to modify the data in the buffer RAM.
9. PC Card Slot
This is the slot to put the control modules in. The AF220 only operates with the
AF220-specific PC cards.
10. Power Switch
I: Power ON
O: Power OFF
13
4. Using the AF220
4.1 Installation
Ethernet Type
Ethernet
PC
AZ290
Hub
Twisted Pair Cable
Control Module
AF220
User System
Target Probe
AC Adapter
AC 110V
Options
•
Remote controller (AZ290 ver 3.0 or higher)
•
Control modules (Requires control modules compatible with your microprocessors)
•
Target probe
14
PC
AZ290
RS-232C Type
RS-232C
AF220
Target Probe
AC Adapter
User System
AC100V
Options
•
Remote controller (AZ290)
•
RS-232 cable (AZ221)
•
Control modules (Requires control modules compatible with your microprocessors)
•
Target probe
15
Standalone Type
Target Probe
AC Adapter
User system
AF220
Control module
Options
•
•
Control module (Requires control modules compatible with your microprocessors)
Target probe
16
4.2 Connecting with User System.
Pin Assignments
AF220 pin assignments are as shown below. For input signals to the user system, YDC recommends that pull-up resisters (about 10 K Ω) be attached considering malfunctions when the AF220 is not connected. The definitions for specific signal lines vary for the control modules. For more information see the manual for your control module.
1 GND
2 TVccd
3 Vcc
4 TRES
5 /TRES
6 TCK
7 NC
8 NC
9 TAUX2
Ground
User system power input (or driver power for I/F when an optional adapter is installed)
5 V output (max. 100 mA)
Rest signal (active high)
Rest signal (active low)
Clock output for synchronous communication
10 /TICS
11 /TOE
12 TMODE
13 TTXD
14 GND
15 GND
16 TVpp1
17 TVpp2
18 WDT
19 TAUX3
Auxiliary input/output pin (Definition may vary depending the type of the Control
Module)
Output pin (Definition may vary depending the type of the Control Module)
Output pin (Definition may vary depending the type of the Control Module)
Transmission data output pin (also can be receive pin for bi-directional transfer)
Ground
Ground
Programming voltage output pin (max. 200 mA)
Variable voltage output pin (0-12 V, max. 100 mA)
20 TAUX4
Auxiliary input/output pin (Definition may vary depending the type of the Control
Module)
Auxiliary input/output pin (Definition may vary depending the type of the Control
Module)
21 NC
22 NC
23 TAUX
24 TBUSY
25 T10
Auxiliary input/output pin (Definition may vary depending the type of the Control
Module)
Busy input signal for synchronous communication
Input pin (Definition may vary depending the type of the Control Module)
26 T11
27 TRXD
Not used (or user power monitor input when an optional adapter is installed)
Receive data input pin
28 GND Ground
Connector: DX10-28S (Hirose)
If you use /TICS then use pull-up resisters (about 10 KΩ).
Type
-
1
4
7
3
2
3
-
-
3
-
5
4
-
3
3
3
5
2
4
1
6
-
6
6
-
-
4
17
Type 1
To VHC244&125 VCC
To voltage monitor circuit
Type 2
LM36
47K
47K
0.1u
1u
AF220 side User Target side
TVccd
47K
0.1u
1u
1M
TI1
LM36
LS07
220
AF220 side User Target side
1M
Type 3
VHC244
220
AF220 side User Target side
1M
18
Type 4
Type 5
VHC125
220
AF220 side User Target side
1M
2SA1362
10
0.22u
AF220 side User Target side
1M
Type 6
HCT541
10K
1M
AF220 side User Target side
Tyep 7
AF220 side User Target side
1
FUSE
19
1. Control Module Check
After checking that the control module is compatible with the target microprocessor then insert it in the AF220 PC card slot
2. Turning the Power On
Turn the power switch ON. The initialization process begins. When the initialization process is completed the control module model name will be displayed on the LDC. Then turn ON the power for the user system.
3. Setting Ethernet (AF220)
Setting the Communication Channel
Set the communication channel between the AF220 and the PC. RS-232 or Ethernet settings can be used for the channel.
Key Operations LCD Display
E/1/RS-23 2 C / FUNC E 1
Communication channel setup function
▲ ▼
Select Ethernet
SET FUNC SET
Decision
E/1/ETHER N E T /
20
Setting IP Address and Port Number
Set the AF220 IP address and port number.
Example: Set the IP address to "192.0.0.1" and the port number to "1100".
Key Operations LCD Display
FUNC E 2
IP address and port number setup function
1 9 2 ▼
Set the IP address to "192"
0 0 0 ▼
Set the IP address to "0"
0 0 0 ▼
Set the IP address to "0"
0 0 1 ▼
Set the IP address to "1"
1 1 0 0
Set the port number to "1100"
SET FUNC SET
Decision
▼
192.168.
192.168.
192.
192.
192.
E/2/
0.
0.
0.
0 .
0 .
0 .
0 .
0 .
0
0
0
0
1
0 x 1 1 0 0
21
Setting Gateway Address
Set the gateway address if the AF220 will be accessed from different networks or from the same network using routers. If the AF220 and the PC are on the same network then set the gateway address to "0.0.0.0".
Example: Set the gateway address to "192.0.0.254".
Key Operations LCD Display
FUNC E 3
Gateway address setup function
1 9 2 ▼
Set the gateway address to "192"
0 0 0 ▼
Set the gateway address to "0"
0 0 0 ▼
Set the gateway address to "0"
2 5 4 ▼
Set the gateway address to "254"
SET FUNC SET
Decision
0.
192.
192.
192.
192.
0.
0.
0.
0.
0.
0
0
0
0
0
.
.
.
.
. 2
4. Setting Parameters
The default parameter setting values can be used as they are. The parameter values can be changed if needed. Consult your control module manuals for the default values.
5
0
0
0
0
4
22
4.4 Programming
This manual describes how to operate the AF220 using the keyboard. Consult the AZ290 manual for information on remote controlling via RS-232 and Ethernet. Basic instructions for programming are described below. For more details refer to the list of commands in Chapter 5.
1. Initializing the Buffer RAM*1
Initialize
*2
the buffer RAMarea which corresponds to the flash ROM area of the microcomputer (MCU).
Key Operations
FUNC 2
Buffer RAM initialization function
SET FUNC SET
Decision
*1 Buffer RAM
This is the place where the program data for the MCU is stored. Binary data is converted and stored by loading object files on the buffer RAM. Data can be modified using the edit function (Chapter 5, Section 3). As the buffer RAM is on the PC card the buffer RAM data is preserved when the AF220 power is switched OFF.
*2 Initialization
The buffer RAM data at initialization varies depending on the control module and it will be
"00" or "FF". (Consult your control module manual for information about the data contents.)
23
2. Setting the Execution Address
Set the execution target area for the device function. The default setting is the entire flash
ROM area. Change the default setting if you want to change the programming area.
Example: Change the setting address from "FE0000H" to "FF0000H".
Key Operations LCD Display
FUNC
0
Programming area setup function
F E 0 0 0 0
Enter the first address
F F 0 0 0
Enter the last address
SET FUNC SET
Decision
0
▼
▼
0/
0/
0/
/FC000
/FE000
/FF000
0
0
0
/
/
/
F
F
L
/
/
/
If you change the execution address a warning message will be displayed when the AF220 power is restarted.
Execution address
Microprocessor flash ROM area
(Function 0)
(Function D6)
Transfer address (Function F5)
If the above settings are not consistent, a warning message such as "ADDR WARN FC0/F5" will be displayed and there will be a beep. Push the RESET key to cancel the warning. This warning can be ignored if you intentionally use the AF220 with a narrow device function execution area.
24
3. Loading the Object File
Load the user object file in the PC card DOS area on the AF220 buffer RAM. For example, load the "DAT128K.BIN" file.
Key Operations LCD Display
FUNC F 1
File load function
▲ ▼
Select "DAT128K.BIN".
F/1/TEST1
F/1/DAT12
.
8
H
K
E
.
X
B I N
SET FUNC SET
F/ /LOADI N G . . .
Decision
4. Programming
Execute the EPR command to perform the ERASE, BLANK-CHECK, PROGRAM, and
READ-VERIFY commands sequentially. Each command can be executed individually. (The available commands vary depending on the control modules. For more information consult your control module manual.)
Key operations LCD Display
DEV F
EPR command
SET DEV SET
Decision
ERASING
BLANK CH E C K I N G
Displayed sequentially
PROGRAMM I N G
READ CHE C K I N G
D/ /PASS / / 0 0
25
5. List of Commands
Command
File operation
Command contents Command key
File Load
File Save
File Purge
Current File Display
Transfer Address Setting
Buffer area editing
Edit
Block Store
Buffer Clear
Modified Bit Search
Checksum Value Display
Calls a file from the control modules to the buffer RAM.
Saves the buffer RAM contents to the control module as a file.
Deletes files on the control module.
Displays the name of the file loaded in the buffer RAM.
Sets the buffer RAM address range.
Modifies the buffer RAM contents.
Modifies the data in the specified range of the buffer RAM.
Resets the buffer RAM data to the initial state.
Displays the addresses of the modified buffer RAM data.
Displays checksum value of the buffer RAM data.
"FUNC", "F1"
"FUNC", "F2"
"FUNC", "F3"
"FUNC", "F4"
"FUNC", "F5"
"FUNC", "1"
"FUNC", "2"
"FUNC", "3"
"FUNC", "93"
YSM File Check
Parameter settings
Execution Address Setting
UART/CSI Switchover
UART Baud Rate Setting
TVcc Threshold Setting
MCU Mode Setting
Performs sumcheck using the YSM file.
Sets the device function execution address range.
"FUNC", "98"
"FUNC", "0"
Sets the communication channel between the AF2xx and the target system. "FUNC", "D1"
Sets the baud rate for UART communication.
Sets the target system operating voltage.
Target MCU mode switchover.*2
"FUNC", "D2"
"FUNC", "D3"
"FUNC", "D4"
Watchdog Timer Setting Sets the pulse to be sent to the watchdog timer circuit in the target system. "FUNC", "D5"
Flash Memory Area Display Displays the data in the target MCU's flash memory area.
Communication Channel
"FUNC", "D6"
Sets the communication channel between the AF2xx and the target system. "FUNC", "D7"
Setting
Changes the model name displayed on the AF2xx. "FUNC", "D8" Displayed Model Name
Change
CSI Baud Rate Setting
Data Format Setting
RS-232C Setting
MCU Operating Frequency
Setting
Sets the CSI communication baud rate.
Sets data format (50:Intel Hex, 60: Motorola S)
Sets the baud rate, data length, stop bit, and parity.
Sets the MCU operating frequency.
"FUNC", "D9"
"FUNC", "5"
"FUNC", "7"
"FUNC", "DF"
Beep Setting
Remote/Local Setting
Version Display
Beep Tone Setting
Battery Remaining
Read Mode Switchover
ON/OFF Setting
Wait T1 Setting
Turns the beep ON or OFF.
Sets the remote/local specification.
Displays the version.
Sets the beep tone (high, medium, low).
Displays the amount of the control module battery remaining
Sets the read check mode.
Application read setting(Contact to YDC in detailes)
Sets the application read ON (enable) or OFF (disable).
Wait T2 Setting
Wait T3 Setting
Wait T4 Setting
Ethernet setting (AF220 only)
Ethernet/RS-232C Switchover Sets the communication channel between the AF220 and the PC.
IP Address/Port Setting
Gateway Address Setting
Sets the AF220 IP address and port number.
Sets the AF220 default gateway address
"FUNC", "91"
"FUNC", "92"
"FUNC", "94"
"FUNC", "95"
"FUNC", "96"
"FUNC", "99"
"FUNC", "DA"
"FUNC", "DB"
"FUNC", "DC"
"FUNC", "DD"
"FUNC", "DE"
"FUNC", "E1"
"FUNC", "E2"
"FUNC", "E3"
* Some commands are not supported for specific MCUs.
* The MCU-specific commands are assigned from "FUNC","81" to "FUNC", "8F". In all cases, refer to your control module manual.
26
Calls the specified object file from the control module.
AF220 Operations
FUNC F
▲ ▼
SET FUNC
1
SET
... File Load command
... Select the name of the file to be loaded.
... Execute object file loading on the buffer RAM.
Operation Example:
Load the "DAT128K.BIN" file from the control module.
AF220 Operations
File Load command
AF220 Display
F / 1 / T E S T 1 .H E X
FUNC
▲
F
▼
1
SET FUNC SET
Execute file loading.
F / 1 / D A T 1 2 8 K .B I N
(Select the file name when it is displayed.)
F / / L O A D I N G ...
(Displayed during loading, and then disappeared when the loading completes.)
27
Saves the AF220 buffer RAM contents onto the DOS area on the PC card as an object file. If you select saving the modified data as a differential file, the automatically created modified object file (three digits will be added to the current file name) will be saved. If you select saving the contents as a new object file, then an empty file will be saved. (Some of the control modules will automatically create RAMxxx.bin, RAMxxx.S, or RAMxxx.HEX file as an empty file.)
*1 Differential file: A file which only saves the modified parts of the object.
*2 It is useful to have an empty object file prepared before using the AF220.
AF220 Operations
FUNC F
▲ ▼
SET FUNC
2
SET
... File Save command
... Select the name of the file to save.
... Execute save on the control module.
Operation Example:
Save the modified data as a differential file. (The current file name is "DAT128K.BIN)
AF220 Operations AF220 Display
FUNC F
SET FUNC
2
SET
File Save command
F 2 / + D A T 1 2 8 K . 0 0 0
(Difference file will be created automatically when you save it. Execute saving.)
F / / S A V I N G ...
(Displayed during loading, and then disappeared when the loading completes.)
28
Deletes the object files on the control module.
AF220 Operations
FUNC F
▲ ▼
SET
SET
FUNC or
3
SET
RESET
... File Purge (delete) command
... Select the file to purge.
... Execute file purging.
... To delete push the SET key. To cancel the deletion push the RESET key.
Operation Example:
Delete the "DAT128K.BIN" file from the control module.
AF220 Operations AF220 Display
FUNC F 3
File Purge command
▲ ▼
Select the "DAT128K.BIN" file.
SET FUNC SET
Execute Purge command
SET
Execute removing.
F / 3 / T E S T 1 .H E X
F / 3 / D A T 1 2 8 K . B I N
(Select the file to delete.)
F / / P U R G E O K ?
29
5.2.4 Current File Display (Function F4)
Displays the name of the current file loaded in the buffer RAM. This command also displays
KEY, BTP, YSM, and CSB files. If there are no files, a "NO FILE" message will be displayed.
AF220 Operations
FUNC F
FUNC SET
▲ ▼
4
SET
RESET
Note: AF220 Display
... Current File Display command
... Select display (CFL⇔YSM⇔CSB⇔BTP⇔KEY).
/ F F 0 0 1 / C O P Y
C F L / D A T 1 2 8 K . B I N
(Shadowed section shows the selected item.)
YSM .... YSM file
CSB ..... CSB file
BTP ..... BTP file
KEY..... KEY file
Note:
Some control modules do not support specific functions. In that case, unsupported items will not be displayed.
*YSM File: This is required to use the sumcheck function. For further information see Chapter
7, "Sumcheck Function".
*CSB File: This is required to use the one-action key function. For further information see
Chapter 6, "One-action key function".
* BTP File: This is a programming control program which is required to program the MCU.
According to the type of the MCU this file may be required. For further information see your control module manual.
* KEY file: There are times when MCUs with security functions need KEY files. For further information see your control module manual.
30
Operation Example:
Display the current file, BTP file, KEY file, YSM file, and CSB file.
AF220 Operations AF220 Display
FUNC F 4
F / / 4 / /
Current File Display command
SET FUNC SET
YSM file is displayed.
▼
C F L / D A T 1 2 8 K .B I N
(Current file is displayed with “CFL” leading.)
Execute the command → Current file is displayed.
▼
Y S M / D A T 1 2 8 K .Y S M
(YSM file is displayed with “YSM” leading.)
C S B / D A T 1 2 8 K .C S B
(CSB file is displayed with “CSB” leading.)
CSB file is displayed.
▼
B T P / M 0 0 1 H 0 1 .B T P
(BTP file is displayed with “BTP” leading.)
BTP file is displayed.
▼
K E Y / D A T 1 2 8 K .K E Y
(KEY file is displayed with “KEY” leading.)
Key file is displayed.
RESET
Display completed.
31
5.2.5 Transfer Address Setting (Function F5)
This carries out the buffer RAM range setting when object file loading and saving is done. For object files with Intel HEX and Motorola S formats the files contain address descriptions so that at the file loading time the settings are not used.
AF220 Operations
FUNC F
Enter the first address
Enter the last address
SET FUNC
5
SET
▲
▲
... Transfer Address Setting command
... Enter the first address.
... Enter the last address.
... Execute transfer address setting.
Notes: AF220 display during address settings.
/ F F 0 0 1 / C O P Y
-F ... First address
F / / F E 0 0 0 0 / - F /
(Shadowed section shows the selected item.)
-L ... Last address
Operation Example:
Set the first address to "FE0000 and the last address to "FFFFFF".
AF220 Operations AF220 Display
FUNC
F
5
Transfer Address Setting command
F E 0 0 0
Enter the first address.
F F F
Enter the last address.
SET FUNC SET
F
F F
0
▲
▲
1 /
1 / / F E 0 0 0 0 / - F /
(Check that “-F” (first address) is displayed.)
1 / / F F F F F F / - L /
(Check that “-L” (last address) is displayed.)
Execute transfer address setting.
/ F C 0 0 0 0 / - F /
32
5.3 Buffer RAM Editing
5.3.1 Edit (Buffer RAM Content Modifications)
Calls the contents of the specified buffer RAM address to edit them.
AF220 Operations
Enter the address
Enter the modified data
SET
SET
...Enter the address.
...Modify the data.
Operation Example:
Modify the data of the buffer address "FE0000" to "00".
AF220 Key Operations
F E
0 0
Enter the address "FE0000".
0 0 SET
Modify the data to "00".
0 0
SET
AF220 Display
/ / F E 0 0 0 0 / F F / F F
/ / F E 0 0 0 0 / 0 0 / F F
(Changing moves to next address.)
* Buffer RAM
This is the location to store the data to program the MCU.
The data is converted to binary data and saved by loading the object file onto the buffer
RAM. Even if the AF220 power is OFF the buffer RAM data is preserved because the buffer RAM is on the PC card.
33
5.3.2 Block Store (Modifying Buffer RAM Contents)
Fills the specified range of the buffer RAM with the same specified data.
AF220 Operations
FUNC 1
Enter the first address
Enter the last address
Enter the modified data
SET FUNC SET
▲
▲
...Block Store command
...Enter the first address.
...Enter the last address.
...Enter the new data.
...Execute buffer modifying.
Note:
AF220 display during address and data entries.
/ F F 0 0 1 / C O P Y
1 / / F E 0 0 0 0 / - F /
-L... Last address
(Shadowed section shows the selected item.)
-d...
34
Operation Example:
Modify data in the buffer RAM addresses from "FE0000" to "FEFFFF" to "55".
AF220 Operations AF220 Display
1 / / F C 0 0 0 0 / - F /
FUNC 1
Block Store command
F E 0
Enter the first address.
F E F
Enter the last address.
5 5
Enter the new data.
SET FUNC SET
F
0
Execute buffer modifying.
F
0
F
0
▲
▲
1 /
(Check that “-F” (first address) is displayed.)
1 / / F E F F F F / - L /
(Check that “-L” (last address) is displayed.)
1 /
/ F E 0 0 0 0 / - F /
/ 5 5 / - d /
(Check that “-D” (data) is displayed.)
35
5.3.3 Buffer Clear (Buffer RAM Initialization)
Initializes the buffer RAM which corresponds to the flash memory area (displayed by Function D6).
AF220 Operations
FUNC 2
...Buffer
SET FUNC SET
...Execute buffer clearing.
* Initialization
The data at the time of buffer RAM initialization will differ from the control module and this will be "00" or "FF". (Consult your control module manual concerning the data contents.)
36
5.3.4 Modified Bit Search (Modified Data Search)
Searches for and displays the addresses of the modified buffer RAM data, which correspond to the flash memory area (displayed by Function D6).
AF220 Operations AF220 Display
FUNC
SET
3
FUNC SET
...Modified Bit Search command 3 / / F E 0 0 0 0 / /
F / / S E A R C H I N G
(Searching the modified data.) searching.
▲ ▼
If modified data is found,
...Display the addresses located.
(▲: Next, ▼:Previous)
F / M / F E 0 0 0 1 / 1 1 / 0 1
(Displays the address for modified data.)
If no modified data is found,
/ / / /
(Nothing is displayed.)
37
Displays the checksum values of the object file loaded on to the buffer RAM. The two types of checksum values below will be displayed
F0: Checksum value for the device function execution area set using Function 0.
F5: Checksum value for the buffer RAM area set using Function F5.
AF220 Operation AF220 Display
9 3
Display command
9 / / 3 / /
FUNC SET
S U M value display.
RESET
S U M F
Display
C H E C K I N G
0 / 0 1 F 5 / 0 1
38
5.3.6 YSM File Check (Function 98)
Compares the YSM file contents and the buffer RAM contents. For more information see
Chapter 7, " Sumcheck Functions".
AF220 Operation AF220 Display
9 8
9 / / 8 / /
Display command
FUNC SET checksum
K I N G value display.
/ / P A S S / /
Error Display
•
YSM FILE NOT FOUND
(Displayed if sumcheck is passed. If an error occurs, the error location will be displayed.)
Cause: Displayed when the YSM file is not found.
Action: Copy the YSM file on the PC card.
•
YSM FILE FORMAT ERROR
Cause: The YSM file has the wrong description or the file is corrupted.
Action: Check that the YSM file has the proper format and correct it.
•
YSM CHECK ERROR YSM/XX RAM/YY
Displayed when checksum values differ during a check.
XX shows the checksum value described in the YSM file, while YY shows the checksum value for the buffer RAM.
•
YSM CHECK ERROR ADDRESS:ZZZZZZZ
Displayed when the data described on the YSM file and the buffer RAM data differ during a check. ZZZZZZZ shows the error address.
39
5.4.1 Execution Address Setting (Function 0)
Sets the target area for the device function execution. Make sure that the first address and the
ROM first address match.
AF220 Operations
FUNC 0
Enter the first address
Enter the last address
Enter the ROM first address
▲
▲
... Execution Address Setting command
... Enter the buffer RAM first address.
... Enter the buffer RAM last address.
... Enter the flash memory first address.
SET FUNC SET
Note: AF220 display during address entries.
... Execute address setting.
(Shadowed section shows the selected item.)
L........ Last
AL..... Block rF....... ROM first address
* Some control modules do not display the ROM first address.
* When the block alignment is ON and you try to specify the address within a block, the alignment is performed automatically.
40
Operation Example:
Set the first address to "FE0000", the last address to "FFFFFF", and the ROM first address to "FE0000".
AF220 Operations AF220 Display
0 / / F C 0 0 0 0 / F /
FUNC 0
Execution Address Setting command
F E 0 0 0
Enter the first address.
F F F F
Enter the last address.
F E 0 0
Enter the ROM first address.
SET FUNC
SET
F
0
Execute address execution setting.
0
F
0
▲
▲
0 / / F E 0 0 0 0 / F /
(Check that “F” (first address) is displayed.)
0 /
(Check that “L” (last address) is displayed.)
0 /
/ F F F F F F / L /
/ F E 0 0 0 0 / r F /
(Check that “rF” (ROM first address) is displayed.)
41
5.4.2 Communication Channel Setting (Function D1)
Sets the communication channel between the AF220 and the target system. You can select
"UART" or "CSI" for the communication channel to accommodate the MCU specifications.
AF220 Operations AF220 Display
▲
SET
▼
FUNC
Setting command
... Select the channel.
SET
...Execute channel setting.
D / 1 / C S I / /
(Select UART or CSI using the up and down arrow keys.)
42
5.4.3 UART Baud Rate Setting (Function D2)
Sets the UART baud rate if the communication channel between the AF220 and the target system is UART. You can select "2400", "4800", "9600", "19200", "31250", "38400", "57600",
"62500", "76800", or "10400" as the baud rate to accommodate to the MCU specifications.
AF220 Operations AF220 Display
▲ ▼
Baud
2 4 0 0 / /
Setting command
D / 2 / 4 8 0 0 / /
...Select the baud rate.
D / 2 / 9 6 0 0 / /
FUNC SET
D / 2 / 1 9 2 0 0 / / baud rate setting
D / 2 /
D / 2 /
3 1 2 5 0 / /
3 8 4 0 0 / /
D / 2 / 5 7 6 0 0 / /
D / 2 / 6 2 5 0 0 / /
D / 2 / 7 6 8 0 0 / /
D / 2 / 1 0 4 0 0 / /
(Select the baud rate using the up and down arrow keys.)
43
5.4.4 CSI Baud Rate Setting (Function D9)
Sets the CSI baud rate if the communication channel between the AF220 and the target system is CSI. You can select "62.5K", "125K", "250K", "500K", "850K", or "1.25M" as the baud rate to accommodate the MCU specifications.
AF220 Operations
FUNC
▲
D
▼
FUNC
9
SET
...CSI Baud Rate
Setting command
...Select the baud rate.
AF220 Display
D / 9 / 6 2 . 5 K / /
D / 9 /
D / 9 /
1 2 5 K / /
2 5 0 K / / baud rate setting.
D / 9 / 8 5 0 K / /
D / 9 / 1 . 2 5 M / /
(Select the baud rate using the up and down arrow keys.)
44
5.4.5 TVcc Threshold Setting (Function D3)
Sets the minimum operating voltage for the target system. This setting is required because this voltage setting will be used to detect the target system power OFF.
AF220 Operations
D 3
...TVcc Threshold Setting command
FUNC
▲
SET
▼
FUNC SET
...Select the TVcc threshold value.
...Execute TVcc threshold setting.
Operation Example:
Set the TVcc threshold value to "4.5V".
AF220 Operations AF220 Display
D 3
Setting command
D / 3 / 3 . 0 / /
▲ ▼
D / 3 / 4 . 5 / /
(Select the TVcc threshold value using the up and down arrow keys.)
SET FUNC SET
…Execute threshold setting.
* The TVcc detecting accuracy of the AF220 is the set value +- 0.1V.
45
5.4.6 MCU Mode Setting (Function D4)
Sets the MCU mode. Some types of MCUs do not support this command. For further information consult your control module manual.
AF220 Operations AF220 Display
D 4
Setting command
D / 4 / M O D E H / /
▲ ▼
FUNC SET
D / 4 / M O D E L / /
...Select the mode.
(Select the MCU mode using the up and down arrow keys.)
...Execute
SET mode setting.
Note: Some MCUs have different displays.
46
5.4.7 Watchdog Timer Setting (Function D5)
Sets the watchdog timer period.
AF220 Operations
FUNC
▲
SET
D
▼
FUNC
5
SET
...Watchdog Timer Setting command
...Set the period (unit: ms).
...Execute watchdog timer setting.
Operation Example:
Set the watchdog timer period to 10 ms.
AF220 Operations AF220 Display
D 5
Setting command
D / 5 / 2 0 / /
▲ ▼
FUNC SET
D / 5 / 1 0 / /
(Select the period using the up and down arrow keys.)
Execute
SET timer setting.
47
5.4.8 Flash Memory Area Display (Function D6)
Displays the flash memory area of the target MCU.
Display:
Fst: Shows the first address of the flash memory area.
Lst: Shows the last address of the flash memory area.
AF220 Operations AF220 Display
D 6
Display command
F / / 6 / /
SET FUNC SET
F / / F s
Execute. t : 0 0
(Displays the first address.)
0 0 0 0 0 0
▲
RESET
▼
Select the display item. F / / L s t : 0 0 0 0 7 F F F
(Displays the last address.)
48
5.4.9 Communication Channel Setting (Function D7)
▲
SET
Selects the communication channel between the AF220 and the target system. This command is required if more than one channel exists between the AF220 and the target system and you must set the number of the communication channel to use it.
AF220 Operations AF220 Display
D 7
Setting command
0 / /
▼
FUNC SET
F / / 1 / communication channel.
(Select the communication channel using the up and down arrow keys.)
Execute the communication channel setting.
49
5.4.10 Displayed Model Name Change (Function D8)
Changes the model name shown in the AF220 display. Up to 7 characters can be entered for the model name.
Note:
On the AF220 only characters from "0" to "9" and from "A" to "F can be entered. By connecting with the PC and using the software which runs on the PC, you can enter any alpha-numeric characters.
AF220 Operations AF220 Display
FUNC
D
Enter Model Name
FUNC
8
SET
Displayed Model Name
Change command
F / 8 / F M 2 0 1 /
Move the cursor with the ▲ and ▼ keys.
F / 8 / 9 1 6 /
(Pressing either the up or down key moves cursor.) model name change.
50
5.4.11 Data Format Setting (Function 5)
Sets the data format and length per record which will be used for data transfer from the AF220 to the PC. The Intel HEX and Motorola S formats are supported.
Enter "50" for the Intel HEX format or "60" for the Motorola S format.
Note: AF220 display during setting operation.
5 / / 5 0 / - F /
(Shadowed section shows the selected item.)
AF220 Operations
-L...Data length per record setting
FUNC
6
1
SET
FUNC
5
...Data Format Setting command
Enter format
Enter Data length
SET FUNC
▲
SET
...50: Intel HEX, 60: Motorola S
...Enter the data length per record.
...Execute data format setting.
Operation Example:
Set the record length to 16-bit and the format to Motorola S format.
AF220 Operations
5
Data Format Setting command
AF220 Display
5 / / 5 0 / - F /
0
0
FUNC
▲
SET
Motolora S format.
5 / / 6 0 / - F /
(Check that “-F” (first address) is displayed.)
Enter the record length in hexadecimal.
5 / / 1 0 / - L /
(Check that “-L” (last address) is displayed.)
51
5.4.12 RS-232C Setting (Function 7)
Sets the baud rate, data length, stop bit, and parity which will be used to communicate with a
PC via RS-232C interface.
-b: Baud rate setting
-P: Data length, stop bit, parity setting
•
Baud rate setting (-b)
Specify this with a one digit code which corresponds to one of the following eight baud rates.
Baud rate [bps] 2400 4800 9600 19200 38400 57600 76800 115200
Code 1 2 3 4 5 6 7 8
Note: If a communication error occurs, select a lower baud rate.
•
Data length, stop bit, parity settings (-P)
Specify these with a 2-digit code.
DataBits
7 : 7 bits (D6~D0)
D3 D2 D1 D0
8 : 8 bits (D7~D0)
LineBreakCheck
0 : disable
StopBits
0 : Stop bits = 1
1 : Stop bits = 2
Parity
00 : No parity check
01 : Odd parity
10 : Even parity
AF220 Operations AF220 Display
7
Enter baud rate code.
▲
Enter data length and others.
SET FUNC SET command
Set the baud rate.
Set data length and others.
(Check that “-b” (baud rate) is displayed.)
7 / / 8 8 / - P /
(Check that “-P” (parity) is displayed.)
Execute RS-232C settings.
52
5.4.13 MCU Operating Frequency Setting (Function DF)
Sets the MCU operating frequency.
AF220 Operations
FUNC
▲
D
▼
F
...MCU Operating Frequency Setting command
...Select the frequency.
SET FUNC SET
...Execute MCU operating frequency setting.
Operation Example:
Set the MCU operating frequency to 10 MHz.
AF220 Operations AF220 Display
D F
Frequency Setting command
D / F /
▲ ▼
D / F /
...Execute
SET FUNC SET frequency setting.
7 . 5 / /
1 0 . 0 / /
53
5.4.14 Beep Setting (Function 91)
Turns the beep ON or OFF.
Executing this command once changes the setting in the order of "ON"→"OFF"→"Key entry sound only OFF".
Note: Some control modules can not turn OFF the key entry sound alone.
AF220 Operations
FUNC
SET
9
FUNC
1
SET
...Beep On/Off Setting command
...Execute the command.
When "ON" before setting → Goes "OFF"
When "OFF" before setting → Goes " Only key entry sound OFF"
When "Only key entry sound Off" before setting → Goes "ON"
54
5.4.15 Remote/Local Setting (Function 92)
Set to the "Remote" mode if you want to remotely control the AF220 from the PC. In the
"Remote" mode, only the RESET key is enabled.
To cancel the Remote mode push the RESET key.
Note:
If you are using YDC Remote Control Software it will automatically set the mode.
Therefore this operation is not required.
AF220 Operations
FUNC
SET
9
FUNC
2
SET
...Remote/Local Setting command
...Execute the command → Goes to the "Remote" mode.
55
FUNC
SET
▲
RESET
Displays the versions of the AF220 and the control modules.
SOFT VER: Control module version
HARD VER: AF220 version
AF220 Operations
9 4
AF220 Display
Display
6 / / command
FUNC
▼
SET
Execute the command.
S O F T V E R 0 1 . 0 0
(Displays the version on the Control Module.)
Change the display item.
H A R D V E R 0 1 . 0 1
(Displays the version on the AF220 hardware.)
56
5.4.17 Beep Tone Setting (Function 95)
Sets the beep tone. High, medium, or low tone can be selected.
Executing this command once changes the tone in the order of "High", "Medium", and "Low".
AF220 Operations
FUNC
SET
9
FUNC
5
SET
...Beep Tone Setting command
...Execute the command.
57
Displays the battery remaining to preserve the control module memory. If BATTERY
REPLACE is displayed replace the battery promptly.
BATTERY FULL:
BATTERY REPLACE:
BATTERY EMPTY:
Good
Need to change the battery.
Remaining battery level is 0. (The memory contents have been erased.)
Caution:
Be careful as when the memory contents are erased the control program is also erased and the AF220 will not start up.
AF220 Operations AF220 Display
9 6
Display command
9 / /
SET FUNC SET
Execute the command.
B A T T
RESET
Display
E R
•
How to Change the Battery
6 / /
Y F U L L
1. Insert the PC card (control module) in the AF220 and turn the power "ON".
2. After starting the AF220 replace the battery.
At this time leave the AF220 power "ON". Do not turn the AF220 power "OFF" while changing the battery. If the power is "OFF" the PC card data will be erased.
•
Batteries for Memory Preservation
•
Mitsubishi SRAM card (MF3xM1-L6DAT0x)
→ BR2325
•
Maxell SRAM card (ML-xM-TB4Nxx.M-220)
→ CR2025(Maxell)
58
5.4.19 Read Mode Switchover (Function 99)
▲
SET
Toggles the read mode. The AF220 has two read modes.
FULL READ VERIFY: Compares the programmed data in the MCU with the buffer RAM data.
SUM READ VERIFY: Compares the checksum values received from the MCU with the checksum values of the buffer RAM.
Note:
Some control modules do not support mode switchovers.
AF220 Operations AF220 Display
9 9
Switchover command
V E R I F Y
▼
FUNC SET
...Select SUM or FULL.
S U M R E A D V E R I F Y
...Execute Read Mode toggling.
59
5.5.1 Communication Channel Setting (Function E1)
Sets the communication channel between the AF220 and the PC. The channel can be
"RS-232C" or "Ethernet". (This command is for the AF220 only.)
AF220 Operations
FUNC
▲
SET
E
▼
1
...Communication Channel Setting command
...Select the channel.
FUNC SET
...Execute communication channel setting.
Operation Example:
Change the communication channel from RS-232C to Ethernet.
AF220 Operations
FUNC E 1
Communication Channel Setting command
▲ ▼
Select Ethernet.
SET FUNC SET
Execute communication channel setting.
AF220 Display
E / 1 / R S - 2 3 2 C /
E / 1 / E T H E R N E T /
60
5.5.2 IP Address/Port Setting (Function E2)
Sets the IP address and port number for the AF220. (This command is for the AF220 only.)
AF220 Operations
FUNC
▲
E
▼
2
...IP Address/Port Setting command
...Sets the IP address and port number.
SET FUNC SET
...Execute IP address/port setting.
Operation Example:
Set the IP address to "192.0.0.1" and port number to "1100".
AF220 Operations AF220 Display
1 9 2 . 1 6 8 . 0 0
FUNC
E 2
IP Address/Port Setting command
1 9 2 ▼
Set "192" (IP address).
0 0 0 ▼
Set "0" (IP address).
0 0 0
Set "0" (IP address).
▼
0 0 1 ▼
Set "1" (IP address)
1 1 0 0
Set "1100" (port number).
SET FUNC SET
Execute IP address/port setting.
▼
1 9 2 . 1 6 8 . 0 . 0
1 9 2 .
1 9 2 .
1 9 2 .
E / 2 /
0 . 0 . 0
0 . 0 . 0
0 . 0 . 1
0 x 1 1 0 0
61
5.5.3 Gateway Address Setting (Function E3)
Sets the default AF220 gateway address. (This command is for the AF220 only.)
Set the gateway address if the AF220 is accessed from different networks or accessed from the same network using routers. If the AF220 and PC are used on the same network set the gateway address to "0.0.0.0".
AF220 Operations
FUNC
E 3
▲
SET
▼
FUNC SET
Operation Example:
...Gateway Address Setting command
...Set the gateway address.
...Execute gateway address setting.
Set the gateway address to "192.0.0.254".
AF220 Operations AF220 Display
0 .
0 . 0 0
FUNC
E 3
Gateway Address Setting command
1 9 2 ▼
Set "192" (gateway address).
0 0 0 ▼
Set "0" (gateway address).
0 0 0 ▼
Set "0" (gateway address).
2 5 4 ▼
Set "254" (gateway address).
SET FUNC SET
Execute gateway address setting.
1 9 2 .
1 9 2 .
1 9 2 .
1 9 2 .
0 . 0 . 0
0 . 0 . 0
0 . 0 . 0
0 . 0 . 2 5 4
62
5.6 List of Device Functions
Command Command contents
Copy
Command key
Reads data from the flash memory to the buffer RAM and performs read check.
"DEV", "8"
Blank Check Checks if the flash memory is erased before programming. "DEV", "9"
Erase
Program
Erases the flash memory and performs blank check.
Programs the flash memory and performs read check.
Read Check Compares the flash memory and the buffer RAM.
E.P.R.
"DEV", "C"
"DEV", "D"
"DEV", "E"
Executes the Erase, Blank Check, Program, and Read Check commands sequentially.
"DEV", "F"
* The functions of some MCUs do not support these commands. Consult your control module manual.
Caution:
The "HV" message appears in the upper left corner of the AF220 display while executing a device function. This shows that the programming voltage is being applied to the target system through the probe. To power off the user system or remove the probe, push the
RESET key on the AF200 and then check that the "HV" message is no longer displayed.
63
5.6.1 Copy
Copies the contents of the MCU flash memory to the AF220 buffer RAM. After copying this command compares the imported contents of the buffer RAM with the flash memory contents.
If the contents are copied successfully and match "PASS" will be displayed. If not, the error addresses will be displayed. The execution range for the Copy command is within the range of the flash memory area (FUNC D6).
AF220 Operations AF220 Display
DEV 8
COPYING
...Copy
SET DEV SET
...Execute the command.
READ CHE C K I N G
D/ /PASS / / 0 0
64
Checks that the flash memory area of the MCU has been erased. If the flash memory contents have been erased "PASS" will be displayed. If not, the address of the bits that have not been erased or the top address of the erased block including that address will be displayed. The execution range for the Blank Check command is within the device function execution range
(FUNC 0).
AF220 Operations AF220 Display
DEV 9
SET DEV SET
...Blank Check command
...Execute the command.
BLANK CH E C K I N
D/ /PASS / /
G
65
5.6.3 Erase
Erases the contents of the flash memory of the internal MCU. After erasing this command performs a blank check and verifies erasure has been successful. If the erasure has been successful, then "PASS" will be displayed. If not, the error address will be displayed. The execution range for the Erase command is within the device function execution range (FUNC 0).
AF220 Operations AF220 Display
DEV C ERASING
...Erase
SET DEV SET
...Execute the command.
BLANK
D/
CH
/PASS
E C
/
K I N G
/
66
5.6.4 Program
Writes the AF220 buffer RAM contents in the MCU flash memory area. Then this command compares the flash memory contents with the buffer RAM contents. If the buffer RAM contents match the MCU flash memory contents "PASS" will be displayed. If not, the error address on the buffer RAM will be displayed. The execution range for the Program command is within the device function execution range (FUNC 0).
AF220 Operations AF220 Display
DEV D
PROGRAMM I N G
...Program
SET DEV SET
...Execute the command.
READ CHE C K I N G
D/ /PASS / 0 0 /
67
Compares the MCU flash memory contents with the AF220 buffer RAM contents. If the data matches "PASS" will be displayed. If not, the error address or the top address of the erased block including that address will be displayed. The execution range for the Read Check command is within the device function execution range (FUNC 0).
There are two types of Read modes; "FULL READ VERIFY" and "SUM READ VERIFY".
See Section 5-4-19, "Read Mode Switchover (Function 99)" for setting the mode.
Some MCUs do not support the flash memory area reading function. The AF220 uses the application read function from the user system to read the programs. Reading the ROM contents is the means by which copying and reading can be done for unsupported devices. For more information on the application read function consult Appendix 1 and Appendix II of your manual.
Note:
Some control modules do not support the Read Mode Switchover command (Function 99).
AF220 Operations AF220 Display
DEV E
...Read
READ CHE C K I N G
SET DEV SET
...Execute the command.
D/ /PASS / / 0 0
68
5.6.6 E.P.R.
Writes on the internal flash memory area of the MCU. This command executes the Erase,
Blank Check, Program, and Read Check commands sequentially. If the E.P.R. command is completed successfully "PASS" will be displayed. If not, the error message will be displayed.
The execution range for the E.P.R. command is within the device function execution range
(FUNC 0).
Note:
Some control modules do not support these commands. For further information consult your control module manual.
AF220 Operations AF220 Display
DEV F ERASING
...E.P.R.
SET DEV SET
...Execute the command.
BLANK CH E C K I N G
PROGRAMM I N G
READ
D/
CHE
/PASS
C K I N G
/ 0 0 / 0 0
69
6. One Action Key Function
Control modules that support one-action key functions can execute device functions with one touch key entries. The two keys in the figure below, OneActionKey1 and OneActionKey2, can be assigned for this function. The usual key operation
DEV * SET DEV SET will not be necessary to execute the device functions and OneActionKey1 and OneActionKey2 can be used to execute these functions with one touch entries.
OneActionKey1
OneActionKey2
70
6.2 One Action Key Setting
6.2.1 Command Sequence File (*.CSB)
The command sequence file (extension: CSB) is used for one-action key setting. Only one CSB file can exist on the DOS area of the control module.
6.2.2 Command Sequence File Format
The command sequence file is a text file and stores the information on which device functions
(command sequence) are assigned to the OneActionKeys.
L K 1 , CNT1 CNT2 , C1
,
C2
, ・・・ ,
C16 ; Comment
L K 2 , CNT1 CNT2 , C1
,
C2
, ・・・ ,
C16 ; Comment
5 6
1
2
1. KeyNo code (3 bytes)
3 4
LK1: OneActionKey1/ LK2: OneActionKey2
2. ',' (1 byte)
Shows the command delimiter.
3. CNT1 and CNT2 (2 bytes)
Shows the number of device commands.
Decimal notation (after "09" is "10")
Maximum: "16"
For unused keys use "00".
4. Cn
Device commands ... See Table 1 on next page.
5. ';' (1 byte)
Shows the comment delimiter.
6. Comment (any number of bytes + CRLF)
Describes the comment.
71
Table 1. Key definitions
D9
DC
DD
DE
DF
Cn Description
F0(XXXXXXXX YYYYYYYY) Device function area setting
(XXXXXXXX: First address, YYYYYYYY: Last address) *1
F1(XXXXXXXX YYYYYYYY ZZ) Block store
(XXXXXXXX: First address, YYYYYYYY: Last address, ZZ: Data) *2
F2 Buffer memory clear
FF1(XXXXXXXX. XXX)
FF5(XXXXXXXX YYYYYYYY)
File load
(XXXXXXXX. XXX: Load file name) *3
Transfer address setting
(XXXXXXXX: First address, YYYYYYYY: Last address) *1
Blank (Device function)
Erase (Device function)
Program (Device function)
Read (Device function)
E. P. R (Device function)
*1 These settings can be omitted. When omitted, the address becomes the entire flash ROM area.
*2 These settings can be omitted. When omitted, the address becomes the entire flash ROM area and the data becomes “00”.
*3 This setting cannot be omitted.
72
Error messages will be displayed for 3 seconds after a beep sounds. Messages, causes, and actions are as shown below:
1. CSB NOT FOUND
Cause: This error will occur if a command sequence file is not found in the DOS area, multiple command sequence files are found in the DOS area, or the command sequence file has the wrong format.
Action: Check that there is only one command sequence file in the DOS area and that it has the proper format.
2. LK1 ASSIGN ERR/ LK2 ASSIGN ERR
Cause: This error will occur if the settings information in the command sequence file has any inconsistencies (undefined device commands, unmatched number of device commands, or others).
Action: Correct the setting information in the command sequence file.
73
7. Sumcheck Function
This function checks the checksum values and data at specified addresses for every device function execution. As this check is done for every device function execution it is possible to prevent incorrect object data from being written.
7.2 Sumcheck Function Settings
The YSM file (extension: YSM) is used for the sumcheck function settings. Only one YSM file can be exist in the DOS area of the control module. If there is a YSM file in the DOS area of the control module when a device function is executed, then the sumcheck function will be executed. Before executing the device function the YSM file data is compared with the buffer
RAM data. If it passes the check then the device function is executed. After reading and executing the device function a comparison is then carried out between the YSM file checksum value and the value at execution read time.
74
7.2.2 YSM File Format
The YSM file is in the Motorola S format. Use the AZ281 (option) to create this file.
Line 1 SUM Data
Set the checksum value for the object data.
Address: 00000000, Size: 1, Type: HEX
Data: Checksum value for the object data
Line 2 SUM Data Check Flag
Set whether Line 1 will be checked or not.
Address: 00000000, Size: 1, Type: HEX
Data: Checked (1), Not checked (0)
Line 3 Data1
Set the data address and other information for the check.
Address: Data top address
Size: Data size
Type: HEX or ASCII
Line 4 Data1 Check Flag
Set whether Line 3 will be checked or not.
Address: 00000000, Size: 1, Type: HEX
Data: Checked (1), Not checked (0)
These settings will generate the file below. (Motorola S format file)
1 S3060000000000F9
2 S3060000000001F8
← SUM Data Check Flag
3 S30B00000100010203040506DE
← Data1
4 S3060000000001F8
← Data1 Check Flag
5 S70500000000FA
From line 3, you can add as many data and check flag pairs as you want up to a maximum of
10 items.
75
8. Specifications
Ambient temperature: 5 to 40 ℃
Humidity:
Power:
20 to 80% (no condensation)
AF220 DC input Voltage: 6 to 16V
Current: 0.4A or less (average)
AC adapter input Voltage: 90 to 264 VAC
Current: 1 A rms (115 VAC)
0.5 A rms (230 VAC)
Physical dimensions: 210 (L) X 148 (W) X 44 (H)
76
Connector pin arrangement (mate side view)
DELC-J9PAF-13L6 ( JAE )
5 1
9 6
Supported baud rates are as shown below.
2400 bps
4800 bps
9600 bps
19200 bps
38400 bps
57600 bps
76800 bps
*
115200 bps
*
* If a communication error occurs, select a lower baud rate.
77
Connector for DOS/V (9 pin female - 9 pin female)
AZ221
DEU-9SF-P0 ( JAE ) DEU-9SF-P0 ( JAE )
AZ221 connection diagram
5
6
7
8
9
Pin
No
1
2
3
4
AF220/210
Signal Name
NC
RXD
TXD
DTR
SG
NC
RTS
CTS
NC
AZ221
3m
5
6
7
8
9
Pin
No
1
2
3
4
PC
Signal Name
DCD
RXD
TXD
DTR
SG
NC
RTS
CTS
RI
78
AZ222: Connector for PC98 (25 pin male - 9 pin female)
AZ222
DEU-9PF-P0 ( JAE ) DBU-25PF-P0 ( JAE )
D9S-FF ( SANWA SUPLY )
AZ222 connection diagram
4
5
6
7
8
9
Pin
No
1
2
3
AF220/210
Signal Name
NC
RXD
TXD
DTR
SG
NC
RTS
CTS
NC
AZ222
3m
4
5
6
7
20
Pin
No
1
2
3
PC
Signal Name
FG
TXD
RXD
RTS
CTS
DSR
SG
DTS
79
Connector pin arrangement (mate side view)
8
TM11R-5L-88( HRS )
1
Pin No
1
2
3
4
5
6
7
8
Signal Name
TXD+
TXD-
RXD+
N.C.
N.C.
RXD-
N.C.
N.C
80
Connector pin arrangement (mate side view)
IC7-68PD-1.27DS-EJR ( HRS )
1 34
35
Signal Name
D5
D6
D7
GND
D3
D4
/CE1
A10
/OE
A11
A9
A8
A13
A14
/WE
N.C.
Vcc
Pin
No
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
Pin
No
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
Signal Name
A5
A4
A3
A2
N.C.
A16
A15
A12
A7
A6
A1
A0
D0
D1
D2
WP
GND
Signal Name
GND
/CD1
N.C.
N.C.
N.C.
N.C.
N.C.
/CE2
N.C.
N.C.
N.C.
A17
A18
A19
A20
A21
Vcc
Pin
No
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
Pin
No
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
Signal Name
N.C.
A22
A23
A24
A25
N.C.
N.C.
N.C.
N.C.
/REG
BVD2
BVD1
N.C.
N.C.
N.C.
/CD2
GND
68
81
8.5 External Key Entry Interface
Connector pin arrangement (mate side view)
5 1
10 6
TX20A-10R-D2LT1-A1LH (JAE)
Definition
1 RST+
2 OAK1+
3 OAK2+
4 Reserved
5 Reserved
6 RST-
7 OAK1-
8 OAK2-
9 Reserved
10 Reserved
ONE ACTION KEY 1 + Pin (LINE KEY 1)
ONE ACITON KEY 2 + Pin (LINE KEY 2)
ONE ACTION KEY 1 – Pin (LINE KEY 1)
ONE ACTION KEY 2 – Pin (LINE KEY 2)
* The OneActionKey1 is the top right blank key and the OneActionKey2 is the bottom right blank key.
* By shorting the positive terminal and negative terminal of each signal the applicable key on the AF220 keyboard will go in a pressed state.
82
Key entering 1
Key entering 2
TPWL TINT
TPWL
8.5.4 EXT.KEY Interface Cable (AZ223)
AZ223
Plug : TX20A-10PH1-D2P1-D1( JAE )
1m
C a b l e : U L 2 7 2 7 6 - S B ( M A ) 1 0 P
×
2 8 A W G ( 7 / 0 . 1 2 7 ) ( H I T A C H I C A B L E )
Wiring Diagram
RST+
RST-
OAK1+
OAK1-
OAK2+
OAK2-
Reserved
Reserved
Reserved
Reserved
4
9
3
8
5
10
1
6
2
7
TX20A-10PH1-D2P1-D1
Orange ■
Orange □
Grey ■
Grey □
White ■
White □
Yellow ■
Yellow □
Pink ■
Pink □
■ :
Dot mark black
□ : Dot mark red
83
8.6.1 Connector (TARGET PROBE)
Connector pin arrangement (mate side view)
14 1
•
28
DX10-28S ( HRS )
15
Vpp output are as shown below:
Voltage (±5%)
Current (max value)
0 - 3.0 (V)
3.0 - 12.5 (V)
10 (mA)
200 (mA)
•
TVcc input is 2.7 - 5.25 (V).
84
This is used for the DX10-28S (HRS) or equivalent connector mounted on the target board.
AF200-side
(Target-side)
DX-28-CV
(Connector Cover w/ One-Touch Lock)
Target-side
(AF200-side)
Standard Probe
A: AZ210
1m
1
15
DX31A-28P
14
28
1 14
The pin layouts are viewed from the cable side.
DX31A-28P
15
*Connectors
Manufacturer: Hirose Electoronics
28
AZ210 Wiring Table
18
19
20
21
22
23
24
25
26
27
28
14
15
16
17
10
11
12
13
7
8
5
6
9
3
4
1
2
AZ210 : AF200-side(Target-side)
Standard Signal Pin Assign
Pin No.
AF200
Standard Signal Name
GND
TVcc
Vcc
TRES
/TRES
TCK
GND
GND
TAUX2 (TR/W)
/TICS
TAUX5 (/TOE)
TMODE
TTXD
GND
GND
TVpp1
TVpp2
WDT
TAUX3 (TVpp1C)
TAUX4 (TVpp2C)
GND
GND
TAUX
TBUSY
TI0
TI1
TRXD
GND
18
19
20
21
22
23
24
25
26
27
28
14
15
16
17
10
11
12
13
7
8
5
6
9
3
4
1
2
AZ210 : Target-side(AF200-side)
Standard Signal Pin Assign
Pin No.
AF200
Standard Signal Name
GND
TVcc
Vcc
TRES
/TRES
TCK
GND
GND
TAUX2 (TR/W)
/TICS
TAUX5 (/TOE)
TMODE
TTXD
GND
GND
TVpp1
TVpp2
WDT
TAUX3 (TVpp1C)
TAUX4 (TVpp2C)
GND
GND
TAUX
TBUSY
TI0
TI1
TRXD
GND
Full 28 pin-to-pin wired.
85
If the connector can not be mounted on the target board then use this cable to connect test clips to test pins or others.
Target-side
AF200-side
Standard Probe
B: AZ211
1m
1 14 2 20
0.25m
Test Clips:
Signal x 20
GND x 1
DX31A-28P
15
(Hirose Electronics)
28 1
PS-20PE-D4LT1-B1
(JAE)
The pin layouts are viewed from the cable side.
19
AZ211 Wiring Table
Enlarged View
Pin No.
7
8
9
10
11
12
13
4
5
6
1
2
3
14
15
16
17
18
19
20
AZ211(AZ213) : Target-side
Test Clips Signal Assign
Lead Color
Brown
Red
Orange
Yellow
Green
Blue
Violet
Grey
White
White & Black
White & Brown
White & Red
White & Orange
White & Yellow
White & Green
White & Blue
White & Violet
White & Grey
Yellow & Green
Light-Blue
AF200
Signal Name
TRXD
TTXD
TVccs (TI1)
TMODE
TI0
TAUX5 (/TOE)
TBUSY
/TICS
TAUX
TAUX2 (TR/W)
TAUX4 (TVpp2C)
TCK
TAUX3 (TVpp1C)
/TRES
WDT
TRES
TVpp2
Vcc
TVpp1
TVccd
GND (Black) : Directry Soldered to PWB.
I/O
O
O
O
I
O
O
O
O
I
O
I
O
I
O
O
I
O
O
O
O
※
The lead color of pin No.19 has been changed from “Light-Green”
to “Yellow & Green” to distinguish it from “Green”.
The pin No.19 which you have may be “Light-Green”.
21
22
23
24
25
26
27
28
14
15
16
17
18
19
20
7
8
9
10
11
12
13
4
5
6
1
2
3
AZ211(AZ213) : AF200-side
Standard Signal Pin Assign
Pin No.
AF200
Standard Signal Name
GND
TVccd
Vcc
TRES
/TRES
TCK
Reserved
GND
TAUX2 (TR/W)
/TICS
TAUX5 (/TOE)
TMODE
TTXD
GND
GND
TVpp1
TVpp2
WDT
TAUX3 (TVpp1C)
TAUX4 (TVpp2C)
GND
Reserved
TAUX
TBUSY
TI0
TVccs (TI1)
TRXD
GND
86
You can customize the connector and wiring.
DX-28-CV
(Connector Cover w/ One-Touch Lock)
AF200-side
Target-side
Standard Probe
C: AZ212
1m
1 14
DX31A-28P
15 28
The pin layouts are viewed from the cable side.
AZ211 Wiring Table
AZ212 : AF200-side
Standard Signal Pin Assign
17
18
19
20
13
14
15
16
21
22
23
24
25
26
27
28
6
7
4
5
1
2
3
8
9
10
11
12
Pin No.
AF200
Standard Signal Name
GND
TVcc
Vcc
TRES
/TRES
TCK
GND
GND
TAUX2 (TR/W)
/TICS
TAUX5 (/TOE)
TMODE
TTXD
GND
GND
TVpp1
TVpp2
WDT
TAUX3 (TVpp1C)
TAUX4 (TVpp2C)
GND
GND
TAUX
TBUSY
TI0
TI1
TRXD
GND
*Connectors (DX31A-28P, DX-28-CV)
Manufacturer: Hirose Electoronics
17
18
19
20
13
14
15
16
21
22
23
24
25
26
27
28
6
7
4
5
1
2
3
8
9
10
11
12
Pin No.
AF200
Standard Signal Name
GND
TVcc
Vcc
TRES
/TRES
TCK
GND
GND
TAUX2 (TR/W)
/TICS
TAUX5 (/TOE)
TMODE
TTXD
GND
GND
TVpp1
TVpp2
WDT
TAUX3 (TVpp1C)
TAUX4 (TVpp2C)
GND
GND
TAUX
TBUSY
TI0
TI1
TRXD
GND
AZ212 : Target-side
Wiring Specification
Insulator
Color
White
Yellow
Orange
Grey
White
Yellow
Pink
Orange
Grey
White
Yellow
Pink
Orange
Grey
White
Pink
Orange
Grey
White
Yellow
Pink
Orange
Grey
White
Yellow
Pink
Orange
Grey
Dot Mark
■
■
■■
■■
■■
■■
■■
■■■
■■
■■■
■■■
■■■
■■■
■
■
■
■■■
■■■
■■■
■
■
■
■
■
■■
■■
■■
■■
Black
Black
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
87
9. Maintenance Service
9.1 Maintenance Service Contract Recommendation
YDC offers preventive and quick repair services which allow our customers to always use their AF220s in excellent running condition and to produce great results.
Our maintenance service period is set to support you for the lifetime of your specified machine.
The lifetime maintenance service system is available by contract when you buy your AF220.
Our maintenance service include:
1. Taking care of repairs when failures occur
2. System software revision service
3. Loaning backup AF220s during the repair period
In addition YDC also offers our Engineering Service (ES) as an optional service contract. With this service contract and with our customer's cooperation we will propose a solution to the customer by determining and analyzing the problems when the customer connects the AF220 to the user system.
Through these services we believe that our customers can use the AF220 effectively for various purposes with a high up rate and increase their productivity. Please see our
"Maintenance Service Information" and make good use of it.
YDC offers product maintenance and repair parts for a period which lasts five years after YDC stops production for that product.
88
YDC offers both maintenance service and optional ES service. Our maintenance service menu and, for your reference, our on-call service menu which is available after your contract expires, are displayed below.
Work contents
Taking care of repairs
Lifetime maintenance contract
◯ Parts included in the lifetime maintenance contract are free of charge for repairs.
*1
On call service
◯ Fee based repairs
(rates for your reference)
Loaning a backup
AF220 during repairs
◯ Loaning a backup AF220 during repairs is free of charge.
◯ Fee based loan
AF220 (rates for your reference)
Software revision up
◯ Offering revision up information
To meet your needs, YDC will ship the latest software without any charge.
△ Revision up is fee based. optional service
*2
◯ Optional contract
(ES optional service)
This service provides technical supports for problems when the writer and target system are connected as shown on the separate ES
Optional Service list.
×
Note
*1 Cable, probe, and battery replacements are not included. In addition repairs that are the responsibility of the customer will require additional payment.
*2 In addition to the standard service, the Engineering Support service contract is required.
89
9.3.1 Purpose
The smooth connection of the target system and the writer.
•
YDC offers the examination of problems when your target system and writer are connected and then presents measures to solve those problems.
•
ES optional service is available from AM 9:00 to PM 5:00.
<On Carrying Out ES Optional Service>
•
You shall provide the equipment we need for our maintenance service. In addition, you shall provide effective information on your target system when we need the information during our investigation.
•
After investigation, YDC can provide additional hardware and/or software which is needed to fix the problem. This service is not covered by this service contact regardless of the cause of the problem. There are extra charges for these services.
•
YDC provides a special order model name for the above added hardware and software and manages it.
•
For services outside of the above time YDC also charges an extra fee.
•
If our service engineer travels to provide services, our hourly rates during normal hours are within the range in the contract, but YDC does charge for travel expenses such as transportation and lodging. YDC also charges extra for services outside of our normal
9:00 AM to 5:00 PM hours.
9.3.3 Others
•
ES optional service supplements the maintenance support for the control modules
(Fx-xxx).
•
In order to obtain ES optional service you must have the ES optional service contract for the attached control module and the lifetime maintenance service for the control module and the AF220.
90
The first six months after you purchase your AF220 is our period of free maintenance service.
During this period you can obtain our standard service free of charge.
<Maintenance Service Conditions>
Our lifetime maintenance service is a maintenance support option for the flash writer (AF220) and control module. After six months of the period of use (lifetime) of your flash writer a new maintenance contract agreement is necessary if you would like a maintenance agreement. The contents of this agreement may vary depending on the lifetime of your AF220. YDC is currently conducting a six month extension campaign, so if you enter into a lifetime maintenance contract when you purchase your flash writer, then YDC will extend the above free maintenance contract period to one year.
Please complete the information on the maintenance contract application form on the next page and sign up at our Instruments Business Division. Furthermore, concerning the maintenance service rates please see the list price which is on a separate sheet. If anything is not clear please contact our Instruments Business Division sales department or a distributor.
Send your registration and lifetime maintenance contract to:
Instruments Business Division Support Center
Yokogawa Digital Computer (K.K.)
91
Yokogawa Digital Computer (K.K.)
User registration and Lifetime Maintenance Contract Application Form
The flash writer lifetime maintenance contract can be concluded by applying as shown below.
<<How to contact you>>
Company name
(Office name)
Section: TEL:
Name: FAX:
<<System configuration>>
(A) Flash writer AF220
•
AF220 serial number:
(Write the serial number which is on the nameplate seal on the back of the AF220)
•
•
Control module model name:
Control module serial number:
(Write the serial number which is on the nameplate seal on the front of the control module PC card)
<<Contract service type and period>>
Check the box and fill in the contents for the service contract
□ 1. Standard service
Contract coverage Purchase date
(A) AF220
(B) Control module
Maintenance contract starting date
Contract period Contract completion scheduled date
□2. ES option (to be contracted for during the control module standard service contract period)
Contract contents
(C) ES optional service
Maintenance contract starting date
Contract period Contract completion scheduled date
*1 YDC is currently conducting a six month extension campaign for customers who enter into maintenance contracts at the time of purchase. YDC will extend the above free maintenance contract period to one year.
*2 YDC believes that our one year service period after purchase is appropriate for almost all of our customers.
92
The company which handles rental machines offers the following two types:
(1) Flash Writer Covered by Maintenance Service
This is the product that YDC has entered into a standard service contract with the rental company for. Customers using our flash writer covered by the maintenance contract can automatically use the standard services shown in our list of maintenance services. In addition customers using our flash writer maintenance contract can use ES optional services that they would like. (There are additional fees.) ES optional service is conducted by contracts between customers and our company. Enter the information in the attached lifetime maintenance contract application form and fax it to us.
YDC also offers an ES Optional Service for shorter periods for customers who will be using our AF220 for a shorter period of time.
(2) Flash Writer not Covered by Maintenance Contract
The rental company is in charge of Flash Writer maintenance service. When YDC provides maintenance services, YDC will ask you for reimbursement for our on-call service fees.
After confirming whether or not the maintenance contract applies to rental products, please contact the department in charge of the maintenance. In addition to the flash writer rental product, the dummy target (DUB) for the self-test function is added to the product for your use. If there are any problems with your AF220 after carrying out self-diagnostics with the dummy target, please contact our support center.
93
9.6 Maintenance Service System
The AF220 support center below is in charge of the flash writer maintenance service.
1. Support Center
Contact the support center below with any maintenance service inquiries you have.
Instruments Business Division Support Center
Yokogawa Digital Computer (K.K.)
Tel: 042-333-6245
Fax: 042-352-6107
For technical inquiries please send them by fax.
2. Maintenance Service Hours
A.M. 9:00 to P.M. 5:00 (Monday to Friday)
94
Fax to 042-352-6107
Instruments Business Division Support Center
Yokogawa Digital Computer (K.K.)
Q&A FAX SHEET
If there are any abnormalities generated while using the product please consult your user manual first. (Be especially sure to conduct the DUB programming test.) If the situation does not return to normal, then fill out the Q&A Fax Sheet items below and send the Fax Sheet to the Support Center. (Please fill out each item and keep a copy for your own use.)
<<How to contact you>>
Company name
(Office name)
Section: TEL:
Name: FAX:
<<System configuration>>
(A) Flash writer AF220
•
AF220 serial number:
(Write the serial number which is on the nameplate seal on the back of the AF220)
•
Control module model name:
•
Control module serial number:
(Write the serial number which is on the nameplate seal on the front of the control module PC card)
<<Problem contents and those conditions>>
Failures or Status (The frequency of the problems, operation procedures, and other things at that time)
Instruments Business Division Support Center (A.M.9:00 to P.M.5:00)
TEL: 042-333-6245
FAX: 042-352-6107
95
Appendix List of Error Codes
Error code
01:WORK RAM ERR
02:BUFFER RAM ERR
Content
Working RAM failure
State/Action
Defective AF220
03:PROGRAM ROM ERR Program ROM failure Defective AF220
04:PC CARD ERR
14:DEVICE ERR XX
15:TVCC TOO LOW
16:VPP1 TOO LOW
17:VPP2 TOO LOW
18:DEVICE ILLEGAL REPLY
XX
19:DEVICE CRC ERR
Target device error
User target voltage low
Vpp1 voltage low
Vpp2 voltage low
Illegal response from MCU
Device communication error
User target MCU abnormality.
Correct wiring.
Correct connection or target power.
*1
User target has a short circuit.
Correct wiring.
User target has a short circuit.
Correct wiring.
Correct connection or communication setting
Correct communication settings.
*1
1A:DEVICE OVERRUN XX
1E:DEVICE NO STR
1F:DEVICE NO KEY
Data has been overwritten before retrieving
Correct the communication settings.
1B:DEVICE FRAMING ERR
XX
1C:DEVICE SEND TIMEOUT
XX
1D:DEVICE RECV TIMEOUT
XX
Baud rate mismatch
AF220 does not transmit in the specified time.
Correct the communication settings.
Correct the connection or the communication settings.
No response from the target MCU in the specified time
Correct the connection or the communication settings.
Could not receive the STR code during Application Read
Keyword mismatch during
Application Read
20:COM I/O ERR
21:COM IN ERR
22:COM OUT ERR
33:DATA FORMAT ERR
Serial I/O line error
Serial IN parity error
Serial OUT timeout
Invalid receive data
Correct host communication settings.
Correct host communication settings.
Correct host communication settings.
Correct host communication settings.
34:DATA ADDRESS ERR
35:FILE CRC ERR
36:HEX ADDRESS
OVERFLOW
37:S5 RECORD CHECK ERR
Data being expanded outside the range of Func D6 address
Intel Hex or Motorola S file checksum value differs from the loaded data checksum value
Correct user object.
Correct user object.
The Intel Hex format file is over the
20 bit address range.
Correct user object.
Motorola S file S5 record value differs from the loaded data checksum value.
Correct user object.
*1
*1
*1
*1
96
40:INVALID PC CARD
42:PC CARD WRITE
PROTECTED
PC card has invalid format.
PC card is write protected.
Defective control module.
Remove the PC card write protect.
43:BATTERY EMPTY PC card battery is empty.
Internal PC card data will be erased.
44:PC CARD PARAMETER
ERR XXXX
45:BATTERY REPLACE
PC card parameter values are invalid. Download proper parameters.
Very little PC card battery remains. Change PC card battery.
*2
*3
50:PC CARD DISK FULL
60:FILE FORMAT ERR
62:MODIFY FILE FULL
64:RAM000 NUM MAX
65:YSM FILE NOT FOUND
No space is left on the PC card.
AF200 has loaded the file with the wrong extension.
The number suffixed to file extension may be over 1000.
The number suffixed to filename may be over 1000.
No YSM file on the PC card
Put in the proper extension.
Modify files can create up to 1000 files.
RAM xxx files can be up to a maximum of 1000 files
Copy the YSM file on the PC card.
66:YSM FILE FORMAT ERR
80:NO LICENCE
Illegal YSM file format
67:YSM CHECK ERR YSM/XX
RAM/YY
YSM file checksum value differs from the checksum value of the data on the buffer RAM.
67:YSM CHECK ERR
ADDRESS:ZZZZZZZ
Data on YSM file at the corresponding address differs from the data on the buffer RAM.
68:UNSPORTED FILE
FORMAT
Check file contents and describe them in the correct format.
AF200 is trying to load a file without a BIN, HEX, or S extension.
AF200 can only load files with a
BIN, HEX, or S extension.
No control module license
Control modules without licenses can not be loaded
E0:ETHERNET ERR XYZ Ethernet connection abnormality See detail code below.
*4
*4
*5
E2:NO BTP FILE No BTP file on the PC card
E3:FILE NOT FOUND There is no file.
*1
XX
01 : ERASE ERROR
02 : BLANK ERROR
03 : PROGRAM ERROR
04 : READ ERROR
05 : COPY ERROR
0F : OTHERS
*2
XXXX: Parameter address error
*3
Consult AF220 manual "Battery Remaining Display" to change battery.
Copy a BTP file on the PC card.
Choose an existing file.
97
*4
XX: YSM file checksum value
YY: Buffer RAM (Func 0 range) checksum value
ZZ:YSM file and the buffer RAM address do not match.
*5
X: Y:
0: Initializing
1: Opening
2: Closing
3: Sending
4: Receiving
5: Connecting
0: Subsystem reset error
1: Subsystem configuration error
2: Opening error
3: IP address setting error
4: Gateway address setting error
5: IP address port address setting error
6: Connect request (Listen) error
7: Connect permission (Accept) error
8: Closing error (Shut)
9: Closing error (Close)
A: Sending error (Send)
B: Receiving error (Recv)
C: Status error
Z:
0: Timeout
1: Request error 1
2: Request error 2
3: Response error 1
4: Response error 2
5: CCB error
6: DB error
7: Line error