American Standard TOWNSQUARE T555.500 Installation instructions


Add to my manuals

advertisement

American Standard TOWNSQUARE T555.500 Installation instructions | Manualzz

TOWNSQUARE

BATH/SHOWER TRIM KIT

Installation

Instructions

T555.500

T555.501

T555.502

PRESSURE BALANCING BATH

AND SHOWER TRIM KIT

Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years.

To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin.

Certified to comply with ANSI A112.18.1

M 9 6 8 2 3 5 Rev. 1. 5

Required Tools

Phillips Screwdriver Flat Blade Screwdriver

Adjustable Wrench

Channel Locks

ROUGHING-IN DIMENSIONS

To assure proper positioning in relation to

wall, note roughing-in dimensions.

2" REF.

FINISHED WALL

1

1-5/8" TO 3-1/4"

1/2" I.P.S.

OPTIONAL TO

FINISHED FLOOR

USUALLY BETWEEN

65'' AND 78''

8" REF.

74" FOR

HEAD CLEARANCE

7-5/8"

18"

OPTIONAL

7-1/4" REF.

1-3/4" REF.

4"

TOP OF

TUB RIM

BOTTOM OF

TUB

1/2" COPPER

Plumbers' Putty or Caulking

1

INSTALL TRIM

CAUTION: Protect finish on SHOWER ARM,

SHOWER HEAD and TUB SPOUT when installing.

When finished tiling the wall, remove PLASTER GUARD (A) and turn off water supply.

Push CAP (1) over VALVE CARTRIDGE (2).

Mount ESCUTCHEON (3) to valve body with SCREWS (4).

Remove PIPE CAPS (5) from shower pipe and tub filler pipe.

Install SHOWER ARM (6), SHOWER HEAD (7) by threading onto pipe nipples using teflon tape or pipe sealant.

Install SLIP-ON TUB SPOUT (8). Tighten with

HEX WRENCH supplied.

2

INSTALL HANDLE

Install HANDLE BUSHING (1) onto CAP (2).

Find correct position of HANDLE (3) and push

HANDLE (3) onto VALVE STEM (4).

Install HANDLE SCREW (5) and push in INDEX

CAP (6).

Check proper operation of HANDLE.

Turn water supply on and test installed fitting.

Operate valve and diverter spout.

7

6

5

1

2

1

A

6

5

3

4

2

3

5

4

1-3

/4

" R

EF.

HEX WRENCH 8

3

ADJUST HOT LIMIT STOP

By restricting HANDLE rotation and limiting the

amount of hot water allowed to mix with the

cold, the HOT LIMIT SAFETY STOP (1) reduces

risk of accidental scalding. To set the maximum

hot water temperature of your faucet, you

need to adjust the setting on the HOT LIMIT

SAFETY STOP (1).

Turn CARTRIDGE STEM (2) to the OFF position

(coldest setting) before making adjustment to

HOT LIMIT STOP (1). Use a flat blade

screwdriver to pry free the HOT LIMIT SAFETY

STOP (1).

Pull forward and rotate counterclockwise

one number to limit hot water temperature.

Use ARROW (3) on CARTRIDGE (4) and

NUMBERS (5) on HOT LIMIT STOP (1) for

indication.

0

531 97

11

13

15

2

3

4

5

1

3

4

3

5

7

9

1

1

3

1

15

COLDER

(Larger Numbers)

0 1 3 5 7 9 11 13 15

2

HOTTER

(Smaller Numbers)

0 1 3 5 7 9 11 13 15

5

15

1

1

3

5

7

9

1

1

3

1

M 9 6 8 2 3 5 Rev. 1. 5

4

TO GAIN ACCESS TO VALVE FOR SERVICING

Pull INDEX CAP, unscrew HANDLE SCREW and pull HANDLE off valve stem.

Remove two SCREWS holding ESCUTCHEON and remove ESCUTCHEON.

Remove COVER by pulling straight out.

Shut off water supply by either closing off main water supply, or closing off the hot and cold CHECK STOPS on valve.

VALVE LEAKS WHEN SHUT OFF

Remove CARTRIDGE (1) by removing CARTRIDGE SCREWS (2). Remove three SCREWS (3) from FIXATION RING (4) and pull out PRESSURE BALANCING (5) unit.

Clean SEALS (9) on base of CARTRIDGE (1). Check base of PRESSURE BALANCING UNIT (5) and clean O-RINGS (6). Remove

CAPS (7) and check O-RINGS on inside of CAPS (7) for debris. Clean inside sealing surfaces of VALVE BODY (8).

Re-assemble PRESSURE BALANCING UNIT (5) and CARTRIDGE (1). Tighten all screws.

Turn on water supply and see above for installing TRIM and HANDLE. If it still leaks, replace pressure balancing unit

(M952100-0070A).

UNABLE TO MAINTAIN CONSTANT TEMPERATURE

Remove PRESSURE BALANCE UNIT (5).

Remove CAPS (7) and clean valve thoroughly.

Examine balancing unit and check condition of O-ring on end of piston. Piston should move back and forth. Order Repair

Part M952100-0070A if balancing unit is defective.

Replace CAPS (7) and install PRESSURE BALANCE UNIT (5). Make sure inlets line up with two holes in bottom of casting.

Top flange should butt-up against top of casting.

BACK TO BACK INSTALLATION

Remove PRESSURE BALANCE UNIT (5). Rotate PRESSURE BALANCE UNIT (5) 180˚ so that the inlets face up and the large outlet port faces down.

Push PRESSURE BALANCE UNIT (5) in casting make sure inlets line up with holes in bottom of casting. Top flange should butt up against top of casting. Reassemble FIXATION RING (4) and CARTRIDGE (1).

ROTATE 180 ˚

8

6

7

5

4 3 9

1 2

LARGE OUTLET

5

INLETS

BACK TO BACK INSTALLATION

5

CARE INSTRUCTIONS:

DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.

DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A

CLOTH WITH A COARSE SURFACE.

M 9 6 8 2 3 5 Rev. 1. 5