Add to my manuals
American Standard TOWNSQUARE T555.500 is a bath and shower trim kit that includes a pressure balancing bath and shower trim kit. It is designed to work with 1/2" I.P.S. connections and features a slip-on tub spout. The trim kit is constructed of durable materials and is backed by a limited lifetime warranty.
Here are some of the features and benefits of the American Standard TOWNSQUARE T555.500:
- Pressure balancing design helps to maintain a consistent water temperature, even when there are changes in water pressure.
- Adjustable hot limit stop allows you to set the maximum hot water temperature, reducing the risk of accidental scalding.
advertisement
TOWNSQUARE
BATH/SHOWER TRIM KIT
Installation
Instructions
T555.500
T555.501
T555.502
PRESSURE BALANCING BATH
AND SHOWER TRIM KIT
Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years.
To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin.
Certified to comply with ANSI A112.18.1
M 9 6 8 2 3 5 Rev. 1. 5
Required Tools
Phillips Screwdriver Flat Blade Screwdriver
Adjustable Wrench
Channel Locks
ROUGHING-IN DIMENSIONS
■
To assure proper positioning in relation to
wall, note roughing-in dimensions.
2" REF.
FINISHED WALL
1
1-5/8" TO 3-1/4"
1/2" I.P.S.
OPTIONAL TO
FINISHED FLOOR
USUALLY BETWEEN
65'' AND 78''
8" REF.
74" FOR
HEAD CLEARANCE
7-5/8"
18"
OPTIONAL
7-1/4" REF.
1-3/4" REF.
4"
TOP OF
TUB RIM
BOTTOM OF
TUB
1/2" COPPER
Plumbers' Putty or Caulking
1
INSTALL TRIM
CAUTION: Protect finish on SHOWER ARM,
SHOWER HEAD and TUB SPOUT when installing.
When finished tiling the wall, remove PLASTER GUARD (A) and turn off water supply.
Push CAP (1) over VALVE CARTRIDGE (2).
Mount ESCUTCHEON (3) to valve body with SCREWS (4).
Remove PIPE CAPS (5) from shower pipe and tub filler pipe.
Install SHOWER ARM (6), SHOWER HEAD (7) by threading onto pipe nipples using teflon tape or pipe sealant.
Install SLIP-ON TUB SPOUT (8). Tighten with
HEX WRENCH supplied.
2
INSTALL HANDLE
Install HANDLE BUSHING (1) onto CAP (2).
Find correct position of HANDLE (3) and push
HANDLE (3) onto VALVE STEM (4).
Install HANDLE SCREW (5) and push in INDEX
CAP (6).
Check proper operation of HANDLE.
Turn water supply on and test installed fitting.
Operate valve and diverter spout.
7
6
5
1
2
1
A
6
5
3
4
2
3
5
4
1-3
/4
" R
EF.
HEX WRENCH 8
3
ADJUST HOT LIMIT STOP
■
By restricting HANDLE rotation and limiting the
amount of hot water allowed to mix with the
cold, the HOT LIMIT SAFETY STOP (1) reduces
risk of accidental scalding. To set the maximum
hot water temperature of your faucet, you
need to adjust the setting on the HOT LIMIT
SAFETY STOP (1).
■
Turn CARTRIDGE STEM (2) to the OFF position
(coldest setting) before making adjustment to
HOT LIMIT STOP (1). Use a flat blade
screwdriver to pry free the HOT LIMIT SAFETY
STOP (1).
Pull forward and rotate counterclockwise
one number to limit hot water temperature.
Use ARROW (3) on CARTRIDGE (4) and
NUMBERS (5) on HOT LIMIT STOP (1) for
indication.
0
531 97
11
13
15
2
3
4
5
1
3
4
3
5
7
9
1
1
3
1
15
COLDER
(Larger Numbers)
0 1 3 5 7 9 11 13 15
2
HOTTER
(Smaller Numbers)
0 1 3 5 7 9 11 13 15
5
15
1
1
3
5
7
9
1
1
3
1
M 9 6 8 2 3 5 Rev. 1. 5
4
TO GAIN ACCESS TO VALVE FOR SERVICING
Pull INDEX CAP, unscrew HANDLE SCREW and pull HANDLE off valve stem.
Remove two SCREWS holding ESCUTCHEON and remove ESCUTCHEON.
Remove COVER by pulling straight out.
Shut off water supply by either closing off main water supply, or closing off the hot and cold CHECK STOPS on valve.
VALVE LEAKS WHEN SHUT OFF
Remove CARTRIDGE (1) by removing CARTRIDGE SCREWS (2). Remove three SCREWS (3) from FIXATION RING (4) and pull out PRESSURE BALANCING (5) unit.
Clean SEALS (9) on base of CARTRIDGE (1). Check base of PRESSURE BALANCING UNIT (5) and clean O-RINGS (6). Remove
CAPS (7) and check O-RINGS on inside of CAPS (7) for debris. Clean inside sealing surfaces of VALVE BODY (8).
Re-assemble PRESSURE BALANCING UNIT (5) and CARTRIDGE (1). Tighten all screws.
Turn on water supply and see above for installing TRIM and HANDLE. If it still leaks, replace pressure balancing unit
(M952100-0070A).
UNABLE TO MAINTAIN CONSTANT TEMPERATURE
Remove PRESSURE BALANCE UNIT (5).
Remove CAPS (7) and clean valve thoroughly.
Examine balancing unit and check condition of O-ring on end of piston. Piston should move back and forth. Order Repair
Part M952100-0070A if balancing unit is defective.
Replace CAPS (7) and install PRESSURE BALANCE UNIT (5). Make sure inlets line up with two holes in bottom of casting.
Top flange should butt-up against top of casting.
BACK TO BACK INSTALLATION
Remove PRESSURE BALANCE UNIT (5). Rotate PRESSURE BALANCE UNIT (5) 180˚ so that the inlets face up and the large outlet port faces down.
Push PRESSURE BALANCE UNIT (5) in casting make sure inlets line up with holes in bottom of casting. Top flange should butt up against top of casting. Reassemble FIXATION RING (4) and CARTRIDGE (1).
ROTATE 180 ˚
8
6
7
5
4 3 9
1 2
LARGE OUTLET
5
INLETS
BACK TO BACK INSTALLATION
5
CARE INSTRUCTIONS:
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
M 9 6 8 2 3 5 Rev. 1. 5