DPI-1200
Digital Ad Server
Thank you for your purchase of the Adtec DPI-1200 Ad Server.
The most recent firmware releases are available on our support website, www.adtecdigital.com.
Advanced users can find direct API command help as part of the on-board web application, Help Tab.
System
Login
Network
Time
NTP
Alarm
Mirror
RAID Status
Name
Firmware
Channels 1 - 12
Not Active
Channel Connected
Pre-Roll / Transitioning
Channel Disconnected
Reset:
Should you need to reset your device, you can do so via the front panel by pressing the
MODE, ESCAPE and
RIGHT ARROW keys simultaneously.
NetSet
<<CH1 - CH12>>
Mode
Days On
Type
Start
Stop
Pre-Roll
Post-Roll
Avail
End By
Splicer Cue
<<CH1 - CH12>> <<CH1 - CH12>>
Mode
Name
DTMF History
DTMF Newest
Splicer IPA DTMF Oldest
Splicer Name
Chassis
Card
Port
Lead In
Schedule ID
GPI State
GPI Time Changed
GPO State
DTMF Speaker
Format
Break Repeat
Multicast IPA
Multicast Port
High Availability:
Each channel is individually configurable for
ASI or IP Streaming.
3 x Mirrored ASI ports allows for connection of up-to 3 separate splicers.
IP streaming via Unicast or Multicast using the GigE Connection.
*Note: If the same Multicast or Unicast address for multiple channels, the Multicast Port will need to be incremented by 2 for each channel.
Example: Channel 1 = Port 2000
Channel 2 = Port 2002
System LED Status
Quick Start Guide
Front Panel Menus:
Use Mode Button to move
through top layer menus.
Use arrows for navigation in submenus.
Use select to enter into edit mode and enter to save selection.
Units ship with the front panel logged in by default. If you become logged out and are prompted for a password, use the following key sequence for access.
Press <Select> when panel displays
‘User Login -- logged out’
Press <Up arrow>
Press <Select>
Press <Enter>
Press <Right arrow>
Press <Enter>
11.25.2013
Getting Connected
To begin, you will need to connect to your device via ethernet directly, or by adding the RD-60 to your local area network.The default address for all Adtec devices is 192.168.10.48.
To connect directly to the device, make sure that your computer and the device have IP addresses within the same IP class range (ex. 192.168.10.48 for the device and 192.168.10.49 for your computer). If you need to change the IP address of the device, this can be done via the front panel,
System > Network menu. Using a CAT 5 crossover cable, connect one end to your computer and the other to the Ethernet port found on the processor section of the back panel. (Some computers can auto negotiate the connection and a crossover may not be necessary.)
To add the device to a LAN, connect a standard CAT 5 Ethernet cable to your network router and then to the Ethernet port on the back of the device. If your network is DHCP enabled and you prefer that over a static IP, you can turn on DHCP for the device via the front panel, System > Network menu.
Web-Based Control Application
Adtec Digital has adopted zero-configuration networking technology, streamlining the setup and configuration processes for our products. The use of this technology enables automatic discovery of Adtec devices and services on an IP network. Used in tandem with the web-based control and configuration applications we can now provide 1-click access to any device.
By using the built-in Bonjour © locater in Apple's © Safari © browser or the plug-ins readily available for IE © or Firefox © browsers, users can locate all of the Adtec devices on a network by referencing the serial number on the back of the device. Clicking on the unit in the Bonjour © list will re-route you to a login page. If you do not wish to use Bonjour, you can reach the device’s web application by pointing your browser to the IP Address of the device. Ex. http://192.168.10.48/. You will be prompted for a username and password. The default username is ‘adtec’. The default password is ‘none’.
The left-hand panel of the application will report current status in real-time while the right panel tabs will allow you to configure your device.
?
Have questions?
Each field or group of fields in our web-based application has a hint button associate with it. It contains information on use of the field or acceptable ranges.
Getting Started
Once your DPI-1200 is accessible via network, you can set it up for Splicer connections. You will need to adjust the configurations using the front panel or web UI. As you make changes, you will see the status sections on the left hand side of the web UI adjust. These status sections report the majority of the critical information needed for monitoring during operation.
Each of these status menus can be collapsed by clicking on the icon. This allows you to view only that information which is most critical for you, but keeps a LED indicator visible for all sections at all times for alarms.
DPI Status:
Includes each channel connection status and method status. One for each channel.
Mirror Status:
These values indicate the FTP Mirroring Mode used on your unit along with the host server IP Address.
System Status:
These values provide information on the status and health of the internal RAID hard drives as well as NTP Time Sync Status with the configured time server.
Processor ..........................................................................................
Power AC Power - Standard 3 pin plug (70-240 VAC 50 - 60 Hz)
GigE
Terminal
Ethernet
RS232
GigE Interface - SPTS/MPTS Output over UDP, FTP, Management
API Serial Communication Interface / Troubleshooting
10/100 base T Ethernet interface
DB9/ Used to communicate with redundancy switch
N/A Intended for future use
External Cue Input and ASI Output ...................................
ASI Redundant BNC 75 Ohm, Asynchronous Serial Interface
Inputs 1&2 (EN 50083-9)
DTMF/GPIO
12 Ports
DTMF Tone Decoder / GPIO Detection board - 4 pin RST
Redundancy Tally Redundancy Tally, used to hook up to an
Relay Block external alarm device
ASI Out 1, 2 & 3 BNC 75 Ohm, Asynchronous Serial Interface
(EN 50083-9) Mirrored MPTS Output
P R
O C E
S S O
R
External Cue Input
& ASI Out put