Toro E-Series Antenna System User Manual
PDF
Tài liệu
Quảng cáo
Quảng cáo
E-Series OSMAC Digital Wireless Paging System Satellite Controller Wide Band to Narrow Band Conversion Kit Installation Instructions Installing the Narrow Band Decoder Module 1. Place the satellite AC power supply switch in the Off position. 2. Remove the clear plastic cover from the decoder module assembly 3. Release the ribbon cable connector from the decoder module by moving the cable receptacle locking tabs outward. 4. Disconnect the remote antenna cable (if installed). Figure 1 5. The decoder module is secured by a self-locking nylon standoff in each corner of the PCB. To remove the module, compress the standoff locking tab (indicated in Figure 1) using needle nose pliers or a flat blade screwdriver, then carefully lift the module upward just enough to keep the locking tab compressed. When all four standoffs are compressed, remove the module. 6. Position the narrow band decoder module onto the standoffs (in the same orientation as the wide band module), then simultaneously press downward on all four corners of the module to lock into position. 7. Place the (keyed) ribbon cable into the receptacle and push inward to lock into position. Figure 2 8. For remote antenna connection: Connect the short antenna cable assembly A B (supplied in the kit) to the receptacle on the decoder module (A) and the antenna or antenna cable BNC receptacle. Using small wire cutters, clip the wire jumper (B) located to the right of the de antenna receptacle. See Figure 2. 9. Place the satellite AC power switch in the On position. 10. When testing is complete (as per instructions on page 2), reinstall the decoder module cover. Selecting the Decoder Radio Frequency The narrow band decoder module stores four user-selectable radio frequencies. The frequencies are programmed at the factory or by the distributor prior to delivery. A set of jumper pins, located at the top center of the decoder module, enable the desired frequency to be selected by placing the jumper on the appropriate pin set. In most cases, the jumper will be configured properly by the distributor prior to delivery. However if a frequency change is desired, place the jumper on the desired pin set number as indicated in Figure 3. Figure 3 Important: The base station transmitter and decoder module must be set to the same frequency to enable communication. #4 Assigning the Satellite Address Number Each satellite requires a 3-digit address number to enable communication with the central controller and/or a hand-held radio. The address numbers range from 1 (001) through 255 and are issued to the satellite through an array of eight DIP switches, located on the decoder module assembly. See Figure 4. In the down position, the switch is Off (open) and represents a value of 0 (zero). In the up position, the switch is On (closed) and represents the following address number: Sw 1 = 1 Sw 2 = 2 Sw 3 = 4 Sw 4 = 8 Sw 5 = 16 Sw 6 = 32 Sw 7 = 64 Sw 8 = 128 To set the satellite address number, place the switch or combination of switches to the On position which provides the numerical equivalent of the desired address number. For example: To set satellite address number 50 (050), start with all eight DIP switches in the Off (open) position, then close switch numbers 2, 5 and 6; i.e., 2 (Sw 2) + 16 (Sw 5) + 32 (Sw 6) = 50. #3 #2 #1 Frequency # Jumper Pin Set Figure 4 O1 2 3 4 5 6 7 8 N DIP Switch Array Performing a Control Circuit Self Test A self-test feature is provided to check the functionality of various key satellite control circuits. Before performing the test, ensure the Field Common, Pump and Station Output control switches are set to the AUTO (down) position. The test is initiated by positioning the TEST/RESET switch, located on the decoder module, to the TEST position as shown in Figure 5. Testing will begin immediately and is indicated by the audible clicks of the control relays and momentary illumination of the LED’s on the various PCB assemblies. The test will repeat continuously until the TEST/RESET switch is positioned to the center (normal operation) position. Note: The RESET position resets the decoder microprocessor to factory defaults. To take affect, the satellite must be powered up with the switch in the RESET position. The switch should be placed in the NORMAL position after 15 seconds of operation. © 2000 The Toro Company, Irrigation Division Figure 5 Test Switch Form Number 373-0125 Rev. A ">
/
Tải xuống
Chỉ là một lời nhắc nhở thân thiện. Bạn có thể xem tài liệu ngay tại đây. Nhưng quan trọng nhất, AI của chúng tôi đã đọc nó. Nó có thể giải thích những điều phức tạp bằng những thuật ngữ đơn giản, trả lời các câu hỏi của bạn bằng bất kỳ ngôn ngữ nào và giúp bạn nhanh chóng điều hướng ngay cả những tài liệu dài nhất hoặc phức tạp nhất.
Quảng cáo