LUMEL P21Z TYPE programmable transducer User’s manual
Below you will find brief information for AC Current and Voltage Transducer P21Z. This programmable transducer converts AC voltage, current, or frequency into standardized DC signals or digital signals via an RS-485 interface. It's compatible with voltage and current transformers and configurable via software (eCon) or a programmer (PD14) to adjust averaging time, conversion characteristics, and output signal behavior under limit conditions. Galvanic isolation protects various internal blocks.
Advertisement
Advertisement
PROGRAMMABLE TRANSDUCER OF AC CURRENT AND AC VOLTAGE SIGNALS AND FREQUENCY P21Z type user’s manual Contents 1. application.........................................................................5 2. Transducer set....................................................................5 3. Basic Requirements and Operational Safety ..........................6 4. installation........................................................................7 4.1 Mounting......................................................................7 4.2 Diagrams of external connections........................................8 5. operation.......................................................................... 10 5.1 Transducer configuration with eCon software......................... 12 5.2 Register map (for version with RS-485)................................ 12 5.3 Manufacturer’s parameters ............................................. 16 6. technical data................................................................... 18 7. Ordering code................................................................... 21 1. APPLICATION P21Z transducers are used for converting one parameter: a.c. voltage, a.c. current or frequency into a standardized direct current signal, direct voltage signal or digital signal available through RS485 interface. The transducers are designed also to work with voltage and current transformers. P21Z transducer may be configured with PD14 programmer. This programmer and eCon software enable users to program the following settings: measurement averaging time, converting characteristics value of output signal when limit value are exceeded, constraining output signal, transmission parameters of RS485. The transducer has galvanic isolation between the individual blocks of: power measurement input, output and PD14 programmer. 2. Transducer set The transducer set includes: P21Z transducer user’s manual guarantee card cap for programmer socket - 1 pc 1 pc 1 pc 1 pc 3. Basic Requirements and Operational Safety The operational safety of the transducer is compliant with the requirements of EN 61010-1 standard The meaning of the following symbol: - Attention! Danger! Observations Concerning the Operational Safety: • All operations concerning transport, installation, and commissioning as well as maintenance, must be carried out by qualified, skilled personnel, and national regulations for the prevention of accidents must be observed. • Before switching the transducer on, one must check the correctness of connections to the network. • Before removing the transducer housing, one must switch the supply off and disconnect measuring circuits. • The removal of the transducer housing during the guarantee contract period may cause its cancellation. • The P21Z transducer is destined to be installed and used in industrial electromagnetic environment conditions. • One must remember that in the building installation, a switch or a circuit-breaker should be installed. This switch should be located near the device, easy accessible by the operator, and suitably marked. 4. Installation 4.1 Mounting P21Z transducers are designed for mounting on a 35 mm according to PN-EN 60715. Dimensions and mounting method are presented in Fig. 1. Connection of PD14 programmer Fig 1. Dimensions and mounting of the transducer. 4.2 Diagrams of external connections The transmitter transducer has a detachable terminal strip with screw terminals that enable user to connect external power supply and output cables with cross section up to 2.5 mm2. Input signals shall be connected with wires of a maximum diameter of 1.5 mm2 to fixed screw terminals. Direct measurement of voltage I1 I1 I2 I1 I1 I2 I1 I2 I2 Direct measurement of current Indirect measurement with voltage transformer I1 I2 I1 I1 I2 I2 I2 Indirect measurement with current transformer I1 I2 I1 I2 Direct measurement of frequency I1 I2 I1 I2 Indirect measurement of frequency with voltage transformer Fig. 2. Electric connections of P21Z inputs. a) analog output supply analog output b) interface RS-485 supply Fig. 3. Electric connections of P21Z power supply and output. 5. Operation After the transducer is switched on, its Status LED should illuminate in red (transducer initialization), then it should turn green (normal operation). Status LED of the transducer: • when illuminated in green – normal operation; • when illuminated in red – incorrect operational parameters; re-configure the transducer; • when flashes in red – no calibration or damaged non-volatile memory; transduce should be returned to the manufacturer; LEDs installed only in version with RS485 interface: RxD LED is on – data receipt; • TxD LED is on – data transmission. • Fig. 4. P21Z transducer view. Data entry into the register is confirmed by a short illumination of the Status LED in red. Before the required number of correct measurements (according to Table 1) is achieved, the device displays arithmetic mean from the completed measurements. Subsequent measurements are added applying the walking window principle, i.e. the “oldest” measurement is deleted and replaced by the most recent one. When values outside the measuring range are measured, the device indicates it and correct measurements are counted from the beginning. Default time is set to 1s. 10 Table 1 Averaging time Number of averaged measurements Refreshing processed value (time of one measurement) 0.5 s 1 every 0.5 s 1s 2 every 0.5 s 3s 6 every 0.5 s 5s 10 every 0.5 s 10 s 20 every 0.5 s 15 s 30 every 0.5 s 30 s 60 every 0.5 s 1 min 100 every 0.6 s 2 min 100 every 1.21 s 5 min 100 every 3 s 7 min 100 every 4.2 s 12 min 100 every 6 s 15 min 100 every 9.1 s The transducer may be programmed with analog output values (values of the output register in RS-485 design) at exceeded input measurement range. The following parameters are adjustable: expected output value when lower limit is exceeded (Out-d) for values below the lower limit (In-d) and expected output value when upper limit is exceeded (Out-u) for values above the upper limit (In-u) – the values are presented in Table 3. 11 5.1 Transducer configuration with eCon software Configuration of P21Z transducers is performed with eCon software available free of charge at www.lumel.com.pl. Detailed description of parameter configuration is presented in the Manual for Transducer configuration with eCon software. Transducers with RS-485 interface may be configured directly via the interface. When configuring the transducer via PD14 programmer, disconnect RS-485 interface. 5.2 Register map (for version with RS-485) Register address Operations Table 2 Range 4000 RW 0..12 Averaging time: 0 – 0.5 s; 1 – 1 s; 2- 3 s; 3 – 5 s; 4 – 10 s; 5 - 15 s; 6 - 30 s; 7 - 1 min; 8 – 2 min s; 9 - 5 min; 10 – 7 min; 11 – 12 min; 12 – 15 min; 4001 RW 0..2 Continuous output: 0 - normal work, 1 – value from register7602, 2- value from register 7603 4002 RW 0..3 Continuous output – Operation with exceeded limit values and type of measured signal: 0 – inactivated, 1 – activated, 4003 RW 1..247 4004 RW 0..3 12 Decription Address in MODBUS network Transmission mode: 0->8n2, 1->8e1,2>8o1, 3->8n1 4005 RW 0..2 Transmission mode: 0->4800, 1->9600, 2->19200 4006 RW 0, 1 Change MODBUS transmission parameters: 1 - change 4007 R 0...65535 4008 R 0 reserved 4009 R 0..65535 reserved 4010 R 0..65535 reserved 4011 R 0..65535 Software version Status Reserved Reserved X X X X X X X X 14 13 12 11 10 9 8 7 Transducer output code Reserved X bity 15 Transducer input code Reserved Reserved Averaging state Range overflow Non-calibrated transducer Error of transducer parameter values Status register description XXXX 6 5 4 XXX 3 2 1 MSB 0 LSB Bit-15 Uncalibrated transducer 0 – transducer measuring input calibrated 1 – signal of uncalibrated transducer input Bit-14 Error of transducer parameter values 0 – transducer parameters correct 1 – signaling of an incorrect transducer parameter readout Bit – 13 Signaling of an range overflow 0 – normal work 1 – range overflow 13 Bit-12 Averaging 0 – full measurement averaging time expired 1 – full measurement averaging time not expired Bits- 11 – 7 Reserved Bits - 6 - 3 Measuring input Bit 6 Bit 5 0 0 Bit 4 Bit 3 Meaning 0 0 reserved 0 0 0 1 100 V a.c. 0 0 1 0 250 V a.c. 0 0 1 1 400 V a.c. 0 1 0 0 1 A a.c. 0 1 0 1 5 A a.c. 0 1 1 0 20...500 Hz Bity-2 - 0 Output Bit 2 Bit 1 Bit 0 Meaning 0 0 0 reserved 0 0 1 current output 0(4)…20 mA 0 1 0 current output 0(4)…20 mA 0 1 1 voltage output 0…10 V 1 0 0 RS-485 14 Register address 2x16 bit Register address 32 bit Operations Table 3 7200 7600 RW Continuous output – lower input value (x1) 7202 7601 RW Continuous output – upper input value (x2) 7204 7602 RW Continuous output – lower output value (y1) 7206 7603 RW Continuous output – upper output value (y2) 7208 7604 RW Input lower overflow In-d 7210 7605 RW Input upper overflow In-u 7212 7606 RW Expected value on the output Out-d at lower overflow In-d 7214 7607 RW Expected value on the output Out-u at upper overflow In-u Description 7216 7608 R Value measured, taking into account registers 7604 and 7605 reg. 7608 = reg. 7604 if reg. 7609 register 7604 reg. 7608 = rej. 7605 if reg. 7609 register7605 7218 7609 R Measured value 7220 7610 R Output value 15 5.3 Manufacturer’s parameters Table 4 Parameter description Range / Value Default value * Averaging time**** 0.5 s; 1 s; 3 s; 5 s; 10 s; 15 s; 30 s; 1 min; 2 min s; 5 min; 7 min; 12 min; 15 min; 1s Continuous output: operation mode normal work, minimum output, maximum output normal work -999999…999999 x1 = 0 or –Un or –In; x2 = Un or In, y1 = 0 or –Un lub –In or 4; y2 = 10 or 20 inactivated, activated inactivated measurement ** Lower input overflow -999999…999999 0 Upper input overflow -999999…999999 Un or In ** Expected value on the output at lower overflow -999999…999999 0, 4 **,1e+20*** Expected value on the output at upper overflow -999999…999999 11 V or 24 mA or 1e+20*** 1…247 1 Continuous output: transition characteristic: (x1, y1) (x2, y2) Continuous output: overflow service Address in MODBUS network *** Transmission mode *** 8n2, 8e1, 8o1, 8n1, 8n2 Baud rate *** 4800, 9600, 19200 9600 16 * - depending on design **- For 4..20 mA version, overflow service is activated, minimum output value is set at 4 mA, input values: minimu and maximum are calculated according to transition data. *** - only for version with RS-485 output ****- for transducers with the input for frequency measurement, the measurement time is always 1s, regardless the values in registers 7200 and 7600. 17 6. technical data Measuring ranges inputs: Measuring range for AC voltage (Un): 0..1..100…130 V a.c. 0..2.5..250…325 V a.c. input resistance > 2 M 0..4..400…600 V a.c. } Measuring range for AC current (In): 0..0.01..1.0…1.3 A a.c. input resistance 10 m 10 % 0..0.05..5.0…6.3 A a.c. input resistance 2 m 10 % Frequency measurement 20...500 Hz: (in range of 24...480 V) ) input resistance > 2 M Analog output current 0(4)…20…24 mA load resistance 250 voltage 0…10…11 V load resistance 500 resolution 0.01 % of range output response time: 200 ms Serial interface RS485: address 1..247 mode: 8N2, 8E1, 8O1,8N1 baud rate: 4.8, 9.6, 19.2 kbit/s transmission protocol: Modbus RTU response time: 200 ms 18 Basic conversion error (by default settings): voltage and current: 0.2% of range in the frequency range 45...65 Hz frequency: 0.02 % of range Additional errors in rated operating conditions: from ambient temperature changes (100 % of basic error/10 K) Sustained overload: 150 % Un (in. 400V a.c.), 120 % Un (other inputs), 120 % In Short duration overload (1 s): voltage input 2 (<1000 V) current input: 10 In Admissible peak factor: current: 2 voltage: 2 Un Rated operating conditions: supply voltage 85..253 V a.c. 40..400 Hz; 90..300 V d.c. 20..40 V a.c. 40..400 Hz; 20..60 V d.c. ambient temperature - 20...23...60 C storage temperature -25...+85 C humidity < 95 % (inadmissible condensation) work position any Averaging time – measurement (programmable): Pre-heating time: 0.5 s 15 minutes 19 Galvanic isolation between: - supply – meas.input: - supply – output: - measuring input – output: 3.2 kV d.c. 2 kV d.c. 3.2 kV d.c. Ensured protection grade acc. to EN 60529: - for the housing IP40 - from the terminal side IP20 Dimensions: 22.5 x 100 x 120 mm Weight: 0.125 kg Fixing: 35 mm rail acc. to EN 60715 Input power: < 3 VA Electromagnetic Compatibility: noise immunity acc. to EN 61000-6-2 noise emissions acc. to EN 61000-6-4 Safety requirements acc. to EN 61010 -1 standard: – isolation between circuits: basic – installation category III (for version 400 V – cat. II) – pollution level 2 – maximal phase-to-earth working voltage: - for power supply circuit 300 V - for measuring input 600 V – cat. II (300 V – cat. III) - for programming input 50 V - for output 50 V – altitude above sea level < 2000 m. 20 7.ordering code PRogrammable transducer of AC CURrent and ac voltage P21Z - X Input signal: 100 V a.c. 1 250 V a.c. 2 400 V a.c. 3 1 A a.c. 4 5 A a.c. 5 frequency 20...500 Hz 6 Output: 0...20 mA 4...20 mA 0...10 V RS-485 Supply voltage: 85..253 V a.c. 40..400 Hz; 90..300 V d.c. 20..40 V a.c. 40..400 Hz; 20..60 V d.c. Version: standard non-standard setti ngs custom-made* Language: Polish English other* Acceptance tests: without extra quality inspecti on requiremnts with an extra quality inspecti on certificate acc. to customer’s request* * - after agreeing with the manufacturer Table 5 X X XX X X 1 2 3 4 1 2 00 NS XX P E X 0 1 X 21 Order example: The code P21Z - 1 1 1 00 E 0 means: P21Z - transducer of d.c. current or d.c. voltage signals 1 - input signal: 1...100 V a.c. 1 - output signal: 0...20 mA 1 - supply voltage: 85..253 V a.c. 40..400 Hz; 90..300 V d.c. 00 - standard version E - English language 0 - without extra quality inspecti on requirements 22 23 LUMEL S.A. ul. Słubicka 1, 65-127 Zielona Góra, Poland Export Department: Tel.: (48-68) 45 75 302 Fax: (48-68) 32 54 091 e-mail: [email protected] 24 P21Z-09 Tel.: (48-68) 45 75 100 Fax: (48-68) 45 75 508 e-mail:[email protected] http://www.lumel.com.pl ">
Download
Advertisement
Key features
Converts AC voltage, AC current or frequency into a standardized DC signal, DC voltage signal or digital signal available through RS485 interface
Can be configured with the PD14 programmer and eCon software to program various settings
Has galvanic isolation between the power, measurement input, output and PD14 programmer
Frequently asked questions
The P21Z TYPE transducer converts AC voltage, AC current or frequency into a standardized DC signal, DC voltage signal or digital signal available through RS485 interface.
The settings that can be programmed include measurement averaging time, converting characteristics, output signal value when limit values are exceeded, constraining output signal, and transmission parameters of RS485.
The transducer has galvanic isolation between the power, measurement input, output and PD14 programmer.