Sentry : Solutions for the Data Center Equipment Cabinet
Key Features
> Remote Power Management:
Power cycle individual power outlets, or groups of power outlets, to remotely reboot servers and network devices, anywhere in the world. Or, power-off unused power receptacles
> High Power Distribution: 120V,
208V, or 230V power; 20-Amp power input feed option
> High Density: Single power input feed; 16 outlets per enclosure
> IP Access & Security: Web interface, SSL, SSH, Telnet, SNMP,
FTP, SNTP, Syslog, LDAP, LDAPS,
TACACS and RS-232 access
> Add an Expansion Module:
Daisy chain the Switched CDU
Expansion Module (CW/CX) for power management of separate power circuits from a single IP address
> Environmental Monitoring:
Each Switched CDU supports two temperature & humidity probes and reports conditions thru the
Web interface
> Enterprise View: View and access up to 1,000 Switched
CDUs from one Web interface**
> SNMP Traps: Provide automated alerts for power and environmental conditions
> Input Current Monitor:
Precisely measure the aggregate current draw (in amps) on each power circuit. On-site verification of the input current with the LED digital display.
Remote verification via browser or serial screen.
> Power-up Sequencing: Prevent an in-rush power overload
Sentry Switched CDU
CW-16V (20-Amp)
High-Density Power Distribution
The Switched CDU’s combine remote configuration and management with power distribution and power and environmental monitoring.
Reboot a single or dual-power server with one command. Receive
SNMP-based alerts and email alerts when power or environmental conditions exceed thresholds. Assign users specific access rights to designated outlets or groups.
Only the Switched CDU products provide the flexibility needed for all data centers and remote sites, including power requirements for high-amp, high voltage; UL 60950-1 (branch circuit protection not required for 20A rated devices); SSL & SSH security; and SNMP-based input current monitoring.
The Switched CDU also supports Enterprise View PDU Manager.
This gives the engineer the ability to manage a large installation of
Networked CDUs from one location, view and access up to 1,000
Switched CDUs from a
single web interface.
Additional Benefits:
Input Current Monitoring
The CDU’s exclusive True RMS current monitoring is critical to preventing overloads in high-density computing environments. LED digital displays on the CDU enclosure report the input current of each phase or branch circuit.
Temperature and Humidity
The Switched CDU supports two external probes. Each of these probes measure both temperature and humidity.
Receive SNMP-based alert notifications when conditions exceed defined thresholds.
Sentry : CDU Technical Specifications
Model
CW-16V1-C20MX
CW-16V2-C20MX
CW-16VE-C20MX
Available Input
Voltages
100-120V
50/60Hz
208-240V
50/60Hz
230V
50/60Hz
Amperage
20A
20A
16A
Available Input
Cord
IEC 60320/C20
Power Inlet
IEC 60320/C20
Power Inlet
IEC 60320/C20
Power Inlet
Outlets
(16) NEMA 5-20R
(16) IEC 60320/C13
Dimensions
(L x W x D)
39.5” x 1.75” x 2.25”
39.5” x 1.75” x 2.25”
(16) IEC 60320/C13 39.5” x 1.75” x 2.25”
Additional Features and Specifications
Agency Approvals
> US & Canada (cTUVus mark) to UL 60950-1:2003 and
CAN/CSA 22.2 No. 60950-1-03
> FCC Class A, Part 15
> CE
> EMC - EN 55022 Class A, EN 55024
> European Union (TUVGS mark) to EN 60950-1:2001
Communications and Security
> 10/100 BaseT Ethernet
> HTTP/HTTPS
> SSLv3/TLSv1
> SNMPv2
> SSHv2
> Telnet
> LDAPv3 and LDAPS
> TACACS+
> RS-232 (Serial)
Branch Circuit Protection (not required)
> Compliant to UL 60950-1
Power Cord Options
> PTCORD-1 IEC 60320/C19 - NEMA L6-20P , 10’
> PTCORD-2 IEC 60320/C19 - Schuko 10’
> PTCORD-3 IEC 60320/C19 - IEC 60309 (BS4343, CEE17)
16/20A Blue (UK Commando) 10’
> PTCORD-4 IEC 60320/C19 - BS1363 13A (UK) 10’
> PTCORD-5 IEC 60320/C19 - 5-15P (15A Straight-Blade) 10’
> PTCORD-6 IEC 60320/C19 - 5-20P (20A Straight-Blade) 10’
> PTCORD-7 IEC 60320/C19 - L5-20P (20A Twist-Lock) 10’
> PT-ADP-C19 Cable mount IEC 60320/C19 Connector
Accessories
> Optional Temperature & Humidity Probe
EMTH-1-1 Temperature & Humidity Probe, 10’
**Enterprise View sold separtely
Expansion Module
Model Numbers
> CX-16V1-C20MX
> CX-16V2-C20MX
> CX-16VE-C20MX
© Server Technology, Inc. 01/26/2007 version. Information in this document is subject to change without notice. Sentry is a trademark of Server Technology, Inc.
Protected by one or more of the following patents: Patent # 7,043,543. Patent Pending. Printed in US.
NORTH AMERICA / ASIA
Server Technology, Inc.
1040 Sandhill Drive
Reno, NV 89521
United States
1.775.284.2000 Tel
1.775.284.2065 Fax [email protected]
www.servertech.com
www.servertechblog.com
EMEA
Server Technology Intl
Sienna Court
The Broadway
Maidenhead
Berkshire
SL6 1NJ
United Kingdom
+44 (0) 1628 509053 Tel
+44 (0) 1628 509100 Fax [email protected]
Sentry : CDU Technical Specifications Sentry : Solutions for the Data Center Equipment Cabinet
Key Features
> Remote Power Management:
Power cycle individual power outlets, or groups of power outlets, to remotely reboot servers and network devices, anywhere in the world. Or, power-off unused power receptacles
> High Power Distribution: 120V,
208V, or 230V power; 20-Amp power input feed option
> High Density: Single power input feed; 16 outlets per enclosure
> IP Access & Security: Web interface, SSL, SSH, Telnet, SNMP,
FTP, SNTP, Syslog, LDAP, LDAPS,
TACACS and RS-232 access
> Add an Expansion Module:
Daisy chain the Switched CDU
Expansion Module (CW/CX) for power management of separate power circuits from a single IP address
> Environmental Monitoring:
Each Switched CDU supports two temperature & humidity probes and reports conditions thru the
Web interface
> Enterprise View: View and access up to 1,000 Switched
CDUs from one Web interface**
> SNMP Traps: Provide automated alerts for power and environmental conditions
> Input Current Monitor:
Precisely measure the aggregate current draw (in amps) on each power circuit. On-site verification of the input current with the LED digital display.
Remote verification via browser or serial screen.
> Power-up Sequencing: Prevent an in-rush power overload
Sentry Switched CDU
CW-16V (20-Amp)
High-Density Power Distribution
The Switched CDU’s combine remote configuration and management with power distribution and power and environmental monitoring.
Reboot a single or dual-power server with one command. Receive
SNMP-based alerts and email alerts when power or environmental conditions exceed thresholds. Assign users specific access rights to designated outlets or groups.
Only the Switched CDU products provide the flexibility needed for all data centers and remote sites, including power requirements for high-amp, high voltage; UL 60950-1 (branch circuit protection not required for 20A rated devices); SSL & SSH security; and SNMP-based input current monitoring.
The Switched CDU also supports Enterprise View PDU Manager.
This gives the engineer the ability to manage a large installation of
Networked CDUs from one location, view and access up to 1,000
Switched CDUs from a
single web interface.
Additional Benefits:
Input Current Monitoring
The CDU’s exclusive True RMS current monitoring is critical to preventing overloads in high-density computing environments. LED digital displays on the CDU enclosure report the input current of each phase or branch circuit.
Temperature and Humidity
The Switched CDU supports two external probes. Each of these probes measure both temperature and humidity.
Receive SNMP-based alert notifications when conditions exceed defined thresholds.
Model
CW-16V1-C20MX
CW-16V2-C20MX
CW-16VE-C20MX
Available Input
Voltages
100-120V
50/60Hz
208-240V
50/60Hz
230V
50/60Hz
Amperage
20A
20A
16A
Available Input
Cord
IEC 60320/C20
Power Inlet
IEC 60320/C20
Power Inlet
IEC 60320/C20
Power Inlet
Outlets
(16) NEMA 5-20R
(16) IEC 60320/C13
Dimensions
(L x W x D)
39.5” x 1.75” x 2.25”
39.5” x 1.75” x 2.25”
(16) IEC 60320/C13 39.5” x 1.75” x 2.25”
Additional Features and Specifications
Agency Approvals
> US & Canada (cTUVus mark) to UL 60950-1:2003 and
CAN/CSA 22.2 No. 60950-1-03
> FCC Class A, Part 15
> CE
> EMC - EN 55022 Class A, EN 55024
> European Union (TUVGS mark) to EN 60950-1:2001
Communications and Security
> 10/100 BaseT Ethernet
> HTTP/HTTPS
> SSLv3/TLSv1
> SNMPv2
> SSHv2
> Telnet
> LDAPv3 and LDAPS
> TACACS+
> RS-232 (Serial)
Branch Circuit Protection (not required)
> Compliant to UL 60950-1
Power Cord Options
> PTCORD-1 IEC 60320/C19 - NEMA L6-20P , 10’
> PTCORD-2 IEC 60320/C19 - Schuko 10’
> PTCORD-3 IEC 60320/C19 - IEC 60309 (BS4343, CEE17)
16/20A Blue (UK Commando) 10’
> PTCORD-4 IEC 60320/C19 - BS1363 13A (UK) 10’
> PTCORD-5 IEC 60320/C19 - 5-15P (15A Straight-Blade) 10’
> PTCORD-6 IEC 60320/C19 - 5-20P (20A Straight-Blade) 10’
> PTCORD-7 IEC 60320/C19 - L5-20P (20A Twist-Lock) 10’
> PT-ADP-C19 Cable mount IEC 60320/C19 Connector
Accessories
> Optional Temperature & Humidity Probe
EMTH-1-1 Temperature & Humidity Probe, 10’
**Enterprise View sold separtely
Expansion Module
Model Numbers
> CX-16V1-C20MX
> CX-16V2-C20MX
> CX-16VE-C20MX
© Server Technology, Inc. 01/26/2007 version. Information in this document is subject to change without notice. Sentry is a trademark of Server Technology, Inc.
Protected by one or more of the following patents: Patent # 7,043,543. Patent Pending. Printed in US.
NORTH AMERICA / ASIA
Server Technology, Inc.
1040 Sandhill Drive
Reno, NV 89521
United States
1.775.284.2000 Tel
1.775.284.2065 Fax [email protected]
www.servertech.com
www.servertechblog.com
EMEA
Server Technology Intl
Sienna Court
The Broadway
Maidenhead
Berkshire
SL6 1NJ
United Kingdom
+44 (0) 1628 509053 Tel
+44 (0) 1628 509100 Fax [email protected]
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement