Server Technology CW-16V1-C20MX Specification Sheet


Add to my manuals
2 Pages

advertisement

Server Technology CW-16V1-C20MX Specification Sheet | Manualzz

Sentry : Solutions for the Data Center Equipment Cabinet

Key Features

> Remote Power Management:

Power cycle individual power outlets, or groups of power outlets, to remotely reboot servers and network devices, anywhere in the world. Or, power-off unused power receptacles

> High Power Distribution: 120V,

208V, or 230V power; 20-Amp power input feed option

> High Density: Single power input feed; 16 outlets per enclosure

> IP Access & Security: Web interface, SSL, SSH, Telnet, SNMP,

FTP, SNTP, Syslog, LDAP, LDAPS,

TACACS and RS-232 access

> Add an Expansion Module:

Daisy chain the Switched CDU

Expansion Module (CW/CX) for power management of separate power circuits from a single IP address

> Environmental Monitoring:

Each Switched CDU supports two temperature & humidity probes and reports conditions thru the

Web interface

> Enterprise View: View and access up to 1,000 Switched

CDUs from one Web interface**

> SNMP Traps: Provide automated alerts for power and environmental conditions

> Input Current Monitor:

Precisely measure the aggregate current draw (in amps) on each power circuit. On-site verification of the input current with the LED digital display.

Remote verification via browser or serial screen.

> Power-up Sequencing: Prevent an in-rush power overload

Sentry Switched CDU

CW-16V (20-Amp)

High-Density Power Distribution

The Switched CDU’s combine remote configuration and management with power distribution and power and environmental monitoring.

Reboot a single or dual-power server with one command. Receive

SNMP-based alerts and email alerts when power or environmental conditions exceed thresholds. Assign users specific access rights to designated outlets or groups.

Only the Switched CDU products provide the flexibility needed for all data centers and remote sites, including power requirements for high-amp, high voltage; UL 60950-1 (branch circuit protection not required for 20A rated devices); SSL & SSH security; and SNMP-based input current monitoring.

The Switched CDU also supports Enterprise View PDU Manager.

This gives the engineer the ability to manage a large installation of

Networked CDUs from one location, view and access up to 1,000

Switched CDUs from a

single web interface.

Additional Benefits:

Input Current Monitoring

The CDU’s exclusive True RMS current monitoring is critical to preventing overloads in high-density computing environments. LED digital displays on the CDU enclosure report the input current of each phase or branch circuit.

Temperature and Humidity

The Switched CDU supports two external probes. Each of these probes measure both temperature and humidity.

Receive SNMP-based alert notifications when conditions exceed defined thresholds.

Sentry : CDU Technical Specifications

Model

CW-16V1-C20MX

CW-16V2-C20MX

CW-16VE-C20MX

Available Input

Voltages

100-120V

50/60Hz

208-240V

50/60Hz

230V

50/60Hz

Amperage

20A

20A

16A

Available Input

Cord

IEC 60320/C20

Power Inlet

IEC 60320/C20

Power Inlet

IEC 60320/C20

Power Inlet

Outlets

(16) NEMA 5-20R

(16) IEC 60320/C13

Dimensions

(L x W x D)

39.5” x 1.75” x 2.25”

39.5” x 1.75” x 2.25”

(16) IEC 60320/C13 39.5” x 1.75” x 2.25”

Additional Features and Specifications

Agency Approvals

> US & Canada (cTUVus mark) to UL 60950-1:2003 and

CAN/CSA 22.2 No. 60950-1-03

> FCC Class A, Part 15

> CE

> EMC - EN 55022 Class A, EN 55024

> European Union (TUVGS mark) to EN 60950-1:2001

Communications and Security

> 10/100 BaseT Ethernet

> HTTP/HTTPS

> SSLv3/TLSv1

> SNMPv2

> SSHv2

> Telnet

> LDAPv3 and LDAPS

> TACACS+

> RS-232 (Serial)

Branch Circuit Protection (not required)

> Compliant to UL 60950-1

Power Cord Options

> PTCORD-1 IEC 60320/C19 - NEMA L6-20P , 10’

> PTCORD-2 IEC 60320/C19 - Schuko 10’

> PTCORD-3 IEC 60320/C19 - IEC 60309 (BS4343, CEE17)

16/20A Blue (UK Commando) 10’

> PTCORD-4 IEC 60320/C19 - BS1363 13A (UK) 10’

> PTCORD-5 IEC 60320/C19 - 5-15P (15A Straight-Blade) 10’

> PTCORD-6 IEC 60320/C19 - 5-20P (20A Straight-Blade) 10’

> PTCORD-7 IEC 60320/C19 - L5-20P (20A Twist-Lock) 10’

> PT-ADP-C19 Cable mount IEC 60320/C19 Connector

Accessories

> Optional Temperature & Humidity Probe

EMTH-1-1 Temperature & Humidity Probe, 10’

**Enterprise View sold separtely

Expansion Module

Model Numbers

> CX-16V1-C20MX

> CX-16V2-C20MX

> CX-16VE-C20MX

© Server Technology, Inc. 01/26/2007 version. Information in this document is subject to change without notice. Sentry is a trademark of Server Technology, Inc.

Protected by one or more of the following patents: Patent # 7,043,543. Patent Pending. Printed in US.

NORTH AMERICA / ASIA

Server Technology, Inc.

1040 Sandhill Drive

Reno, NV 89521

United States

1.775.284.2000 Tel

1.775.284.2065 Fax [email protected]

www.servertech.com

www.servertechblog.com

EMEA

Server Technology Intl

Sienna Court

The Broadway

Maidenhead

Berkshire

SL6 1NJ

United Kingdom

+44 (0) 1628 509053 Tel

+44 (0) 1628 509100 Fax [email protected]

Sentry : CDU Technical Specifications Sentry : Solutions for the Data Center Equipment Cabinet

Key Features

> Remote Power Management:

Power cycle individual power outlets, or groups of power outlets, to remotely reboot servers and network devices, anywhere in the world. Or, power-off unused power receptacles

> High Power Distribution: 120V,

208V, or 230V power; 20-Amp power input feed option

> High Density: Single power input feed; 16 outlets per enclosure

> IP Access & Security: Web interface, SSL, SSH, Telnet, SNMP,

FTP, SNTP, Syslog, LDAP, LDAPS,

TACACS and RS-232 access

> Add an Expansion Module:

Daisy chain the Switched CDU

Expansion Module (CW/CX) for power management of separate power circuits from a single IP address

> Environmental Monitoring:

Each Switched CDU supports two temperature & humidity probes and reports conditions thru the

Web interface

> Enterprise View: View and access up to 1,000 Switched

CDUs from one Web interface**

> SNMP Traps: Provide automated alerts for power and environmental conditions

> Input Current Monitor:

Precisely measure the aggregate current draw (in amps) on each power circuit. On-site verification of the input current with the LED digital display.

Remote verification via browser or serial screen.

> Power-up Sequencing: Prevent an in-rush power overload

Sentry Switched CDU

CW-16V (20-Amp)

High-Density Power Distribution

The Switched CDU’s combine remote configuration and management with power distribution and power and environmental monitoring.

Reboot a single or dual-power server with one command. Receive

SNMP-based alerts and email alerts when power or environmental conditions exceed thresholds. Assign users specific access rights to designated outlets or groups.

Only the Switched CDU products provide the flexibility needed for all data centers and remote sites, including power requirements for high-amp, high voltage; UL 60950-1 (branch circuit protection not required for 20A rated devices); SSL & SSH security; and SNMP-based input current monitoring.

The Switched CDU also supports Enterprise View PDU Manager.

This gives the engineer the ability to manage a large installation of

Networked CDUs from one location, view and access up to 1,000

Switched CDUs from a

single web interface.

Additional Benefits:

Input Current Monitoring

The CDU’s exclusive True RMS current monitoring is critical to preventing overloads in high-density computing environments. LED digital displays on the CDU enclosure report the input current of each phase or branch circuit.

Temperature and Humidity

The Switched CDU supports two external probes. Each of these probes measure both temperature and humidity.

Receive SNMP-based alert notifications when conditions exceed defined thresholds.

Model

CW-16V1-C20MX

CW-16V2-C20MX

CW-16VE-C20MX

Available Input

Voltages

100-120V

50/60Hz

208-240V

50/60Hz

230V

50/60Hz

Amperage

20A

20A

16A

Available Input

Cord

IEC 60320/C20

Power Inlet

IEC 60320/C20

Power Inlet

IEC 60320/C20

Power Inlet

Outlets

(16) NEMA 5-20R

(16) IEC 60320/C13

Dimensions

(L x W x D)

39.5” x 1.75” x 2.25”

39.5” x 1.75” x 2.25”

(16) IEC 60320/C13 39.5” x 1.75” x 2.25”

Additional Features and Specifications

Agency Approvals

> US & Canada (cTUVus mark) to UL 60950-1:2003 and

CAN/CSA 22.2 No. 60950-1-03

> FCC Class A, Part 15

> CE

> EMC - EN 55022 Class A, EN 55024

> European Union (TUVGS mark) to EN 60950-1:2001

Communications and Security

> 10/100 BaseT Ethernet

> HTTP/HTTPS

> SSLv3/TLSv1

> SNMPv2

> SSHv2

> Telnet

> LDAPv3 and LDAPS

> TACACS+

> RS-232 (Serial)

Branch Circuit Protection (not required)

> Compliant to UL 60950-1

Power Cord Options

> PTCORD-1 IEC 60320/C19 - NEMA L6-20P , 10’

> PTCORD-2 IEC 60320/C19 - Schuko 10’

> PTCORD-3 IEC 60320/C19 - IEC 60309 (BS4343, CEE17)

16/20A Blue (UK Commando) 10’

> PTCORD-4 IEC 60320/C19 - BS1363 13A (UK) 10’

> PTCORD-5 IEC 60320/C19 - 5-15P (15A Straight-Blade) 10’

> PTCORD-6 IEC 60320/C19 - 5-20P (20A Straight-Blade) 10’

> PTCORD-7 IEC 60320/C19 - L5-20P (20A Twist-Lock) 10’

> PT-ADP-C19 Cable mount IEC 60320/C19 Connector

Accessories

> Optional Temperature & Humidity Probe

EMTH-1-1 Temperature & Humidity Probe, 10’

**Enterprise View sold separtely

Expansion Module

Model Numbers

> CX-16V1-C20MX

> CX-16V2-C20MX

> CX-16VE-C20MX

© Server Technology, Inc. 01/26/2007 version. Information in this document is subject to change without notice. Sentry is a trademark of Server Technology, Inc.

Protected by one or more of the following patents: Patent # 7,043,543. Patent Pending. Printed in US.

NORTH AMERICA / ASIA

Server Technology, Inc.

1040 Sandhill Drive

Reno, NV 89521

United States

1.775.284.2000 Tel

1.775.284.2065 Fax [email protected]

www.servertech.com

www.servertechblog.com

EMEA

Server Technology Intl

Sienna Court

The Broadway

Maidenhead

Berkshire

SL6 1NJ

United Kingdom

+44 (0) 1628 509053 Tel

+44 (0) 1628 509100 Fax [email protected]

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement