IMPORTANT

Please make certain that the person who is to use this equipment carefully reads and understands these instructions before starting operations.

The Model and Serial No. plate is located on the frame.

Record these numbers in the spaces below and retain for future reference.

Model No.

Type

Serial No.

Part No. D28469-032-0

SAFETY GUIDELINES / DEFINITIONS

This manual contains information that is important for you to know and understand. This information relates to protecting YOUR SAFETY and PREVENTING EQUIPMENT PROBLEMS. To help you recognize this information, we use the symbols below. Please read the manual and pay attention to these sections. i ndicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.

indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.

indicates a potentially hazardous situation which, if not avoided,may result in minor or moderate injury used without the safety alert symbol indicates potentially hazardous situation which, if not avoided, may result in property damage.

Read Operators Manual. Do not operate equipment until you have read operators Manual for Safety, Assembly, Operation, and Maintenance

Instructions.

This product may not be equipped with a spark arresting muffler. If the product is not equipped and will be used around flammable materials, or on land covered with materials such as agricultural crops, forest, brush, grass, or other similar items, then an approved spark arrester must be installed and is legally required in the state of

California. It is a violation of California statutes section 130050 and/or sections 4442 and 4443 of the California Public Resources Code, unless the engine is equipped with a spark arrester, as defined in section 4442, and maintained in effective working order. Spark arrester are also required on some U.S. Forest Service land and may also be legally required under other statutes and ordinances.

Engine exhaust contains chemicals known, in certain quantities, to cause cancer, birth defects or other reproductive harm.

IMPORTANT SAFETY INSTRUCTIONS

Improper operation or maintenance of this product could result in serious injury and property damage. Read and understand all warnings and operating instructions before using.

RISK OF ELECTROCUTION AND FIRE

HAZARD

Attempting to connect generator directly to the electrical system of any building structure.

WHAT CAN HAPPEN

Back feeding electricity through a building’s electrical system to the outside utility feed lines could endanger repair persons attempting to restore service.

HOW TO PREVENT IT

Never backfeed electricity through a structure's electrical system.

D28469 2- ENG

HAZARD

Attempting to connect generator directly to the electrical system of any building structure.

(Continued)

RISK OF ELECTROCUTION AND FIRE

(Continued)

WHAT CAN HAPPEN

Attempting to connect to the incoming utility service could result in electrocution.

Restoration of electrical service while the generator is connected to the incoming utility could result in a fire or serious damage if an isolator switch is not installed.

Failure to use a double throw transfer switch when connecting to a structure's electrical system can damage appliances and

WILL VOID the manufacturer's warranty.

HOW TO PREVENT IT

To connect to a structure's electrical system in a safe manner, always have a Double-Throw

Transfer Switch installed by a qualified electrician and in compliance with local ordinances.

(When installing a Double-

Throw Transfer Switch, a minimum of 10 gauge wiring must be used.)

Operation of generator in rain, wet, icy, or flooded conditions.

Use of worn, damaged, undersized or ungrounded extension cords.

Water is an excellent conductor of electricity! Water which comes in contact with electrically charged components can transmit electricity to the frame and other surfaces, resulting in electrical shock to anyone contacting them.

Contact with worn or damaged extension cords could result in electrocution.

Operate generator in a clean, dry, well ventilated area. Make sure hands are dry before touching unit.

Inspect extension cords before use and replace with new cord if required.

Use of undersize extension cords could result in overheating of the wires or attached items, resulting in fire.

Use of ungrounded cordsets could prevent operation of circuit breakers and result in electrical shock.

Use proper size (wire gauge) cordset for application see chart in the Assembly section of this manual.

Always use a cordset having a grounding wire with an appropriate grounding plug. DO

NOT use an ungrounded plug.

Placing generator on or against highly conductive surface, such as a steel walkway or metal roof.

Accidental leakage of electrical current could charge conductive surfaces in contact with the generator.

Place generator on low conductivity surface such as a concrete slab.

ALWAYS operate generator a minimum of six feet from any conductive surface.

Improper connection of items to generator.

Exceeding the load capacity of the generator by attaching too many items, or items with very high load ratings to it could result in overheating of some items or their attachment wiring resulting in fire or electrical shock.

3- ENG

Read the load rating chart and instructions in the Wattage Calculation section. Make sure that the summation of electrical loads for all attachments does not exceed the load rating of the generator.

D28469

HAZARD

Operation of unit when damaged, or with guards or panels removed.

RISK OF ELECTROCUTION AND FIRE

(Continued)

WHAT CAN HAPPEN HOW TO PREVENT IT

Attempting to use the unit when it has been damaged, or when it is not functioning normally could result in fire or electrocution.

Removal of guarding could expose electrically charged components and result in electrocution.

Do not operate generator with mechanical or electrical problem. Have unit repaired by an Authorized Service Center.

Do not operate generator with protective guarding removed.

RISK OF FIRE

HAZARD

Attempting to fill the fuel tank while the engine is running.

Sparks, fire, hot objects

Improper storage of fuel

Inadequate ventilation for generator

Tampering with factory set engine speed settings.

WHAT CAN HAPPEN

Gasoline and gasoline vapors can become ignited by coming in contact with hot components such as the muffler, engine exhaust gases, or from an electrical spark.

Cigarettes, sparks, fires, or other hot objects can cause gasoline or gasoline vapors to ignite.

HOW TO PREVENT IT

Turn engine off and allow it to cool before adding fuel to the tank. Equip area of operation with a fire extinguisher certified to handle gasoline or fuel fires.

Improperly stored fuel could lead to accidental ignition. Fuel improperly secured could get into the hands of children or other unqualified persons.

Materials placed against or near the generator or operating the generator in areas where the temperature exceeds 104° F. ambient (such as storage rooms or garages) can interfere with its proper ventilation features causing overheating and possible ignition of the materials or buildings.

Add fuel to tank in well ventilated area. Make sure there are no sources of ignition near the generator.

Store fuel in a OSHA approved container designed to hold gasoline. Store container in secure location to prevent use by others.

Operate generator in a clean, dry, well ventilated area a minimum of four feet from any building, object or wall. DO NOT OPERATE

UNIT INDOORS OR IN ANY

CONFINED AREA.

Engine speed has been factory set to provide safe operation.

Tampering with the engine speed adjustment could result in overheating of attachments and could cause a fire.

Never attempt to “speed-up” the engine to obtain more performance. Both the output voltage and frequency will be thrown out of standard by this practice, endangering attachments and the user.

D28469 4- ENG

HAZARD

RISK OF FIRE

(Continued)

WHAT CAN HAPPEN

Overfilling the fuel tank – fuel spillage.

Spilled fuel and its vapors can become ignited from hot surfaces or sparks.

HOW TO PREVENT IT

Use care in filling the tank to avoid spilling fuel. Make sure fuel cap is secured tightly and check engine for fuel leaks before starting engine. Move generator away from refueling area or any spillage before starting engine. Allow for fuel expansion. Keep maximum fuel level ¼ inch below the tip of the fuel tank. Never refuel with the engine running.

HAZARD

Fire, Inhalation,

Damage to

Vehicle Surfaces

RISK OF INJURY AND PROPERTY

DAMAGE WHEN TRANSPORTING

GENERATOR

WHAT CAN HAPPEN

Fuel or oil can leak or spill and could result in fire or breathing hazard, serious injury or death can result. Fuel or oil leaks will damage carpet, paint or other surfaces in vehicles or trailers.

HOW TO PREVENT IT

If generator is equipped with a fuel shut-off valve, turn the valve to the off position before transporting to avoid fuel leaks.

If generator is not equipped with a fuel shut-off valve, drain the fuel from tank before transporting. Transport fuel only in an

OSHA approved container.

Always place generator on a protective mat when transporting to protect against damage to vehicle from leaks. Remove generator from vehicle immediately upon arrival at your destination.

HAZARD

Gasoline engines produce toxic carbon monoxide exhaust fumes.

RISK OF BREATHING - INHALATION

HAZARD

WHAT CAN HAPPEN HOW TO PREVENT IT

Breathing exhaust fumes will cause serious injury or death.

Operate generator in clean, dry, well ventilated area. Never operate unit in enclosed areas such as garages, basements, storage, sheds, or in any location occupied by humans or animals. Keep children, pets and others away from area of operating unit.

5- ENG D28469

RISK OF UNSAFE OPERATION

HAZARD

Operation of generator in careless manner

Operation of voltage sensitive appliances without a voltage surge protector

Raising or suspending generators equipped with lift rings improperly

WHAT CAN HAPPEN

All sources of energy include the potential for injury. Unsafe operation or maintenance of your generator could lead to serious injury or death to you or others.

HOW TO PREVENT IT

• Review and understand all of the operating instructions and warnings in this manual.

• Become familiar with the operation and controls of the generator. Know how to shut it off quickly.

• Equip area of operation with a fire extinguisher certified to handle gasoline or fuel fires.

• Keep children or others away from the generator at all times.

Any gasoline operated household generator will incur voltage variations causing damage to voltage sensitive appliances or could result in fire.

Always use a U.L. listed voltage sensitive surge protector to connect voltage sensitive appliances (TV, computer, stereo, etc.). Failure to use a U.L. listed voltage surge protector will void the warranty on your generator.

Generator could fall causing serious injury or death to you or others.

Improper raising or suspending can cause damage to the generator.

Notice: A multiple outlet strip is not a surge protector. Make sure you use a U.L. listed voltage surge protector

Always use proper connecting procedures as described in this manual when connecting cables, chains, or straps for raising or suspending generators equipped with lift rings.

Always use cables, chains, or straps rated at 2000 lbs working load or more to raise or suspend generator.

Operating generator while suspended

Generator will not operate properly and will cause damage to the generator and could cause serious injury or death to you or others.

Never operate generator while suspended or in an unlevel position. Always operate generate on a flat, level surface.

D28469 6- ENG

RISK OF HOT SURFACES

HAZARD

Contact with hot engine and generator components.

WHAT CAN HAPPEN

Contact with hot surfaces, such as engines exhaust components, could result in serious burns.

HOW TO PREVENT IT

During operation, touch only the control surfaces of the generator. Keep children away from the generator at all times.

They may not be able to recognize the hazards of this product.

HAZARD

Contact with moving parts can result in serious injury.

RISK OF MOVING PARTS

WHAT CAN HAPPEN

The generator contains parts which rotate at high speed during operation. These parts are covered by guarding to prevent injury.

HOW TO PREVENT IT

Never operate generator with guarding or cover plates removed. Avoid wearing loose fitting clothing or jewelry which could be caught by moving parts.

HAZARD

Lifting a very heavy object.

RISK FROM LIFTING

WHAT CAN HAPPEN

Serious injury can result from attempting to lift too heavy an object.

HOW TO PREVENT IT

The generator is too heavy to be lifted by one person. Obtain assistance from others before you try to move it.

7- ENG D28469

CONSUMER GENERAL AND SERVICE INFORMATION

• Please read and follow these instructions for proper use and maintenance.

• If you experience any problems and need assistance, please call us at our toll free number 1-888-559-8550, Monday through Saturday.

• If repair or service part purchase is required, our many Authorized Warranty

Service Centers are conveniently located and equipped to handle all inwarranty and out-of-warranty service.

• For the location of the nearest Authorized Warranty Service Center call

1-888-559-8550, 24 hours a day, 7 days a week.

• Retain sales receipt as proof of purchase for warranty service.

Read and understand all safety warnings.

• Do not operate this unit until you have read and understand this Owners

Manual for Safety, Operation, and Maintenance Instructions.

• Do not operate this unit until you have read and understand the Engine

Owners Manual for Safety, Operation, and Maintenance Instructions.

Note: Photographs and line drawings used in this manual are for reference only and do not represent a specific model.

MODEL

HORSE POWER

RATED/SURGE WATTS

VOLTAGE

AMPERAGE

PHASE

HERTZ

ENGINE SPEED

MAX. AMBIENT TEMP.

FUEL CAPACITY

RUN TIME @ 50%/100%

SPECIFICATIONS

H1000IS

20

10000/19500

120/240V

83.3 A41.7 A

SINGLE

60 Hz

3600 RPM

104° F

7 GALLON

9.9/4.9 HOURS

D28469 8- ENG

ASSEMBLY

Read this manual. Do not attempt to operate equipment until you have read this Manual for Safety, Operation, and

Maintenance Instructions.

NOTE: This manual is a general manual. Information in this manual may or may not pertain to your model. Please read carefully.

NOTE: Left and right describes the location of a part with the operator facing the outlet panel.

UNPACKING

1.

Locate the parts carton and set aside for later use.

2.

Cut wire ties holding generator to pallet and remove protective wrapping.

3.

Remove all packaging, leaving generator on pallet.

IMPORTANT: DO NOT remove generator from pallet.

4.

Discard all packaging.

Wire Tie

Protective

Wrapping

ASSEMBLE WHEEL KIT

Tools needed:

2 - 2x4 at least 30” long

1 - 1/2” socket

1 - 1/2” open end wrench

1 - hammer

1 - pliers

Parts bag contains:

2 - Handle Grips

2 - Handle End Caps

4 - Screws, .313-18X1.75

1 - Cotter Pin

2 - Washers, 5/8" X 1.32 X .09

1 - Flat Steel Washer

2 - Axle Spacer

2 - Cap Screw 5/16-18 X 3/4

6 - Flange Nuts

2 - Wheel Brackets

1 - 5/8” Axle Cap

9- ENG D28469

1.

Lift the gas tank end of generator and slide 2x4 between generator and pallet as shown.

The generator is too heavy to be lifted by one person. Obtain assistance from others before lifting.

Gas Tank

2x4

2.

Place handle grips on handle assemblies.

Handle Grip

3.

Place one 5/8” washer into the bottom of each end cap. Push end caps onto the end of the handle assemblies.

End Cap

Handle

Assembly

4.

Attach handle assemblies to frame using four screws and flange nuts.

NOTE: Screw on outside of frame.

NOTE: Do not tighten until all screws and flange nuts are assembled.

Screws and

Flange Nuts

5/8” Washer

D28469 10- ENG

5.

Lift generator and remove 2x4.

6.

Lift other end of generator and place two 2x4s between generator and pallet as shown.

2x4

7.

On the muffler side of the engine, remove cap screws and flange nuts holding the heat shield to the frame.

Reassemble cap screws, heat shield, wheel bracket, and flange nuts and as shown. Tighten securely.

Cap

Screw

Muffler

Heat

Shield

Flange Nuts

Wheel

Bracket

8.

On other side, assemble wheel bracket using cap screws and flange nuts supplied. Tighten securely.

NOTE: Brackets are placed under frame with hole facing outward.

Cap screws

Wheel Bracket

9.

Using a hammer tap axle cap onto end of axle, without the hole .

10. Slide wheel onto axle with valve stem to the outside.

11. Slide spacer onto axle against wheel.

Hole in Axle

12. Slide axle through axle brackets. NOTE: The pallet will need to be removed before the wheel can be assembled.

13. Lift generator and slide pallet and 2x4s out. NOTE: Generator will tilt.

14. Lift generator and slide spacer, then wheel (with valve stem to the outside) onto axle.

15. Slide flat steel washer onto axle against wheel.

16. Secure with cotter pin.

11- ENG D28469

ASSEMBLE SKYHOOK

Tools needed:

1 - 1/2” socket or open end wrench

1 - 3/8" socket

1 - Torque wrench

Parts bag contains:

1 - Skyhook

2 - Upper brackets

4 - Bolts, 5/16-18 x 7/8”

4 - Lockwashers, 5/16”

4 - Nuts, Whizlock 5/16”

1.

Close fuel shut-off valve on tank by turning clockwise until it stops.

2.

Remove four screws, and washers securing fuel tank to frame. Save screws and washers for reassembly.

3.

Carefully place fuel tank inside frame rails as shown.

4.

Place skyhook under frame as shown.

D28469 12- ENG

5.

Place skyhook on the fuel tank side of the frame and install upper bracket as shown.

6.

Wrap upper bracket around frame.

7.

Slide lockwashers onto bolts, insert through brackets, and secure with whizlock nuts.

NOTE: DO NOT tighten bolts at this time.

8.

Repeat steps 5-7 on other side.

9 Position skyhook between arrows on label. NOTE: Bracket should not overlap onto weld (a).

Failure to properly position skyhook can cause property damage, serious injury or death, and void the manufacturer’s warranty.

10. Torque four bolts to 11-12 ft.-lbs.

(132-144 in.-lbs.)

IMPORTANT: DO NOT substitute hardware when assembling the skyhook.

11. Place tank on frame rails and align holes in tank with holes in frame.

12. Install fuel tank screws and washers. Torque screws to 20-

25 inch pounds (hand tight).

13. Open the fuel shut-off valve. Turn counter clockwise until the valve stops.

13- ENG a

D28469

BATTERY INSTALLATION

The generator is equipped with a maintenance free battery.

1.

For packaging purposes the black negative battery cable and battery were secured with wire ties. Cut these wire ties.

Wire Tie

Negative Battery Cable

2.

Connect black negative cable to negative (-) battery post. Tighten securely. NOTE: Make sure rubber boot is covering positive (+) battery terminal.

NOTE: If battery needs to be charged, follow these instructions.

Wire Tie

When charging the battery, do not smoke.

Keep away from any sparks. The fumes from the battery acid can cause an explosion. To prevent explosive fumes from accumulating do not charge in an enclosed area.

Negative Battery Cable

Sulfuric acid is a flammable and explosive chemical that is harmful to the skin, eyes, and clothing.

Positive

Battery Cable with rubber boot

To prevent sparks, disconnect the black battery cable from the negative (-) terminal before disconnecting the red positive cable.

1.

Remove black negative battery cable from the battery.

2.

Remove red positive battery cable from the battery.

3.

Use a portable 12 volt battery charger, if needed, to bring battery to full charge (12.6 at 70ºF.). Refer to the battery charger’s operator’s manual for the correct procedure. If a battery charger is not available, have an authorized service center charge the battery.

4.

Connect the battery cables.

To Prevent sparks connect the red (positive) cable to the positive (+) terminal before connecting the black negative cable.

When transporting unit over extremely rough terrain by vehicle the battery should be secured.

GROUNDING THE GENERATOR

A grounding lug is supplied with the generator for use when required by local electrical ordinances. Refer to article 250 of the National Electrical Code to clarify any needed grounding information. Your local electric company or a certified electrician should be able to help you with this information.

Grounding Lug

D28469 14- ENG

OBTAINING ELECTRICITY FROM THE GENERATOR

There are basically 2 ways to obtain electricity from a generator:

1.

Use of extension cords directly from the generator to the appliance, lights, tools, etc.

2.

Use of a double-throw transfer switch installed directly to the main electrical supply outside of house.

EXTENSION CORDS

When using an appliance or tool at a considerable distance from the generator, a 3-wire extension cord that has a 3blade grounding plug and a 3-slot receptacle that accepts the tool's plug MUST be used in order to reduce the risk of electrical shock. A cord of adequate size must be used. Using the following chart to determine the minimum wire size required.

An extension cord that is hot to the touch is overloaded. Repair or replace damaged extension cords immediately.

Extension Cord Wire Gauge Chart

Cord

Length

0 to 100 ft.

0 to 100 ft.

Wire

Gauge

Size

12 ga.

10 ga.

Amperage

1 Up to 20 amp draw

2 Up to 30 amp draw

0 to 100 ft.

8 ga.

Up to 40 amp draw

1.

When amperage exceeds 20 amp; a

12 gauge extension cord should not be used for long distances.

2.

When amperage exceeds 30 amp; a

10 gauge extension cord should not be used for long distances.

DOUBLE THROW TRANSFER SWITCH

Potential hazards exist when a portable electric generator is connected to the main electrical supply coming into the house.

It is at that point that the electrical generator could feed back into the utility company's system causing possible electrocution of workers who are repairing the electrical lines.

To avoid back feeding of electricity into utility systems, a double-throw transfer switch must be installed between the generator and utility power. The Double-

Throw Transfer Switch should be installed by a licensed electrician and in compliance with all state and local electrical codes. (When installing a Double-

Throw Transfer Switch, a minimum of 10 gauge wiring must be used.)

The electrician should also install a sub-panel to isolate the circuits you would want to use during an emergency or electrical power outage. Your generator will not be large enough to handle the load of all the lights, appliances, TV, etc. at one time. To select which items to run during the electrical power outage, see

Wattage Calculation section in this manual.

15- ENG D28469

OTHER LOOSE PARTS

1.

Oil is supplied, see engine operator’s manual for correct procedure to add oil and fuel to engine.

2.

The locking plugs maybe used when needed or required.

The locking plugs are to be installed and/or used in accordance with appropriate local electrical code regulations. Refer to instructions enclosed with each plug for proper installation.

3.

12V DC cables to be used with the 12V DC outlets. See Operation section.

IMPORTANT: Before any attempt to start your generator be sure to check engine oil (See Engine Operator's manual)

OPERATION

KNOW YOUR GENERATOR

Read this General Manual and Safety Rules before operation of your Generator.

Compare the illustration in your parts manual with your generator to familiarize yourself with the location of various controls and adjustments. Save all manuals for future references.

GENERATOR CAPACITY

IMPORTANT: Exceeding the rated capacity of your generator can result in serious damage to your generator and connected electrical devices. See the Wattage Calculation section in this manual to assist you in determining the appliances and tools that can be run with the wattage capacity of your generator.

CIRCUIT BREAKERS

Each receptacle has a circuit breaker to protect the generator from overloading. If the circuit breaker trips, unplug all electrical loads from the generator. Let the circuit breaker cool down. Push circuit breaker button to reset.

LOW OIL SHUTDOWN

Your generator engine is equipped with Low Oil Shutdown. Low Oil Shutdown is a safety device designed to protect your engine from damage in the event the oil level in the crankcase is low.

If while the engine is running, the oil gets low, it will automatically shut itself down and will not restart until the oil is added. If the oil is low before start-up, the generator will not start until oil is added.

NOTE: The Low Oil Shutdown mechanism is very sensitive. You must fill the engine to the full mark on the dipstick to inactivate this safety device.

OFF/RUN/START SWITCH

Placed in the start position to start engine and the off position to stop engine.

NOTE: When engine is running switch will remain in the run position.

D28469 16- ENG

IDLE CONTROL

Choose the correct application.

1.

For normal application such as power tools, small electric appliances, light bulbs, and radios:

Place the idle control switch in the ON position. The generator will idle down when there is no load. This lowers the engine noise, saves on fuel consumption, and engine life.

2.

Idling down IS NOT recommend on large motors (refrigerators, freezers, etc) or voltage sensitive electronic equipment (computers, televisions, etc). For these applications:

Place the idle control switch in the OFF position.

12V DC OUTLET

IMPORTANT: Allow generator to run at no load for 5 minutes upon each initial start-up to allow engine to stabilize.

IMPORTANT: When the unit is running the battery will charge. DO NOT connect the 12V DC cables to the generator’s battery.

To charge battery:

1.

Using the 12V DC cables supplied, connect the red positive (+) 12V DC cable to the battery's positive (+) terminal.

2.

Attach the other end of the red positive (+) 12V DC cable to the generators positive (+) 12V DC outlet.

3.

Connect the black negative (-) 12V DC cable to the battery's negative (-) terminal.

4.

Attach the other end of the black negative (-) 12V DC cable to the generators negative (-) 12V DC outlet.

5.

Charge the battery according to battery or equipment manufacturer recommendations.

BEFORE START UP

This generator has been shipped from the factory without oil in the crankcase. Operating the unit without oil can damage the engine.

Always check engine oil level before every start. Running engine low of oil or out of oil could result in serious damage to the engine.

Follow the steps listed below before starting generator:

1.

Check engine oil. Refer to the Engine Operator's Manual for correct grade and quantity of oil.

2.

Check fuel level, fill as required. Make sure generator is turned off and has been allowed time to cool down. Use clean, fresh, regular unleaded gasoline with a minimum of 87 octane. Do not mix oil with gasoline.

Never fill fuel tank completely. Fill tank to 1/2" below the bottom of the filler neck to provide space for fuel expansion. Wipe any fuel spillage from engine and equipment before starting engine.

17- ENG D28469

Never fill fuel tank indoors. Never fill fuel tank when engine is running or hot. Do not smoke when filling fuel tank.

Never run engine indoors or in enclosed, poor ventilated areas, engine exhaust contains carbon monoxide, an odorless and deadly gas.

3.

Make sure generator is grounded in accordance with local requirements.

4.

All electrical loads MUST be disconnected.

5.

Idle control switch must be in the OFF position.

6.

Make sure skyhook bolts are tightened and torqued to 11-12 ft.-lbs. (132-144 in.-lbs.).

Engine speed has been factory set to provide safe operation.

Tampering with the engine speed adjustment could result in overheating of attachments and could cause a fire. Never attempt to “speed-up” the engine to obtain more performance. Both the output voltage and frequency will be thrown out of standard by this practice, endangering attachments and the user.

You MUST unplug any load from the generator before starting to prevent permanent damage to any appliances.

TO START THE ENGINE

Never run engine indoors or in enclosed, poor ventilated areas, engine exhaust contains carbon monoxide, an odorless and deadly gas.

1.

Open the fuel shut-off valve.

2. Move the choke control located on the engine to "CHOKE" position. A cold engine may require to be choked longer than a warm engine.

3. Push ON\OFF\START switch on control panel to the

"START" position to start engine. Hold in "START" position no longer than 15 seconds per minute when trying to start engine. Extended cranking can damage the starter motor.

4.

When engine starts, gradually move the choke to the "NO Choke" position.

IMPORTANT: Allow generator to run at no load for 5 minutes upon each initial start-up to allow engine and generator to stabilize.

STOPPING ENGINE

1. Disconnect all electrical loads.

2. Place the ON\OFF\START switch to "OFF" position.

3. Close fuel shut-off valve.

CONNECTING ELECTRICAL LOADS

1.

Let engine run and warm up for five minutes after starting with no electrical load.

Connect loads in the following manner to prevent damage to equipment:

2.

Connect inductive load equipment first, inductive loads consist of refrigerators, freezers, water pumps, air conditioners, or small hand tools.

Connect the items that require the most wattage first. See Wattage Calcu-

lation Section in this manual.

3.

Connect the lights next.

D28469 18- ENG

4.

Voltage sensitive equipment should be the last equipment connected to the generator. Plug voltage sensitive appliances such at TV's, VCR's, microwaves, ovens, computers, and cordless telephones into a UL listed voltage surge protector, then connect the UL listed voltage surge protector to the generator.

Failure to connect and operate equipment in this sequence can cause damage to equipment and will void the warranty on your generator.

Follow the wattage calculation table in the Wattage Calculation section of this manual. Overloading the generator will cause power fluctuations and can damage equipment and appliances.

DeVilbiss Air Power Company will only be responsible for damage to customer's equipment when the generator is determined to be defective.

This determination will only be made by an authorized representative of

DeVilbiss Air Power Company and this decision will be final. DeVilbiss Air

Power Company reserves the right to inspect the electrical connections at the customer's site of operation and test the generator for proper operation before any determination of liability is made. Failure to maintain the equipment or wiring for inspection will void any claim for damages by the customer. DeVilbiss Air Power Company will not be responsible for equipment damaged as a result of voltage surges, improper operation or improper installation of the generator.

CONNECTING PROCEDURE FOR RAISING OR SUSPENDING

GENERATOR

Failure to properly connect lifting cables, chains, or straps can cause properly damage, serious injury or death, and void the manufacturer’s warranty.

Always use cables, chains, or straps rated at 2000 lbs. working load or more to raise or suspend generator.

Never operate generator while suspended. This could cause property damage, serious injury or death.

DO NOT suspend objects other than generator from skyhook.

1. Route cable, chain, or strap through lift ring as shown. ALWAYS use lift ring when raising or suspending generator.

NOTE: Make sure the generator is in a level position before raising or suspending to prevent damage.

19- ENG D28469

MAINTENANCE

CUSTOMER RESPONSIBILITIES TABLE

MAINTENANCE TASK

Before each use

Every 25

Hours of

Every

Season

See Note 2

Every 50

Hours of

Every

Season

Every 100

Hours of

Every

Season

Check oil level

Change oil

X

See Note 1

Clean Air Filter Assembly

Check Spark Plug

Prepare Unit for Storage

X

X X

Prepare unit for storage if it is to remain idle for more than 30 days.

Note 1: Change oil after first two (2) operating hours and every 50 operating hours thereafter, more often if operated in extreme dusty or dirty conditions.

Note 2: Check oil after 5 hours of operation.

GENERAL RECOMMENDATIONS

The warranty of the generator does not cover items that have been subjected to operator abuse or negligence. To receive full value from the warranty, operator must maintain the generator as instructed in this manual.

ENGINE MAINTENANCE

Refer to the Engine Operator's manual for service and maintenance of the engine.

GENERATOR MAINTENANCE

Your generator should be kept clean and dry at all times. The generator should not be stored or operated in environments that includes excessive moisture, dust or any corrosive vapors. If these substances are on the generator, clean with a cloth or soft bristle brush. Do not use a garden hose or anything with water pressure to clean the generator. Water may enter the cooling air slots and could possibly damage the rotor, stator and the internal windings of the gen head.

GROUND FAULT CIRCUIT INTERRUPTER GFCI RECEPTACLE

MONTHLY: For maximum protection against electrical shock the GFCI should be tested monthly.

To test:

1.

Depress the TEST button. The RESET button should extend. If the RESET button does not extend, notify a DeVilbiss Air Power Company Authorized

Warranty Service Center.

2.

To restore power, depress the RESET button firmly into the GFCI unit until an audible click is heard. If reset properly, the RESET button is flush with the surface of the test button. When the button stays in, the power is ON.

D28469 20- ENG

STORAGE

If you are going to store your generator for more than 30 days, use the following information as a guide to prepare the generator for storage.

Never store generator with fuel in the tank indoors or in enclosed, poorly ventilated areas, where fumes can reach an open flame, spark or pilot light as on a furnace, water heater, clothes dryer or other gas appliances.

ENGINE PREPARATION

1.

Add fuel stabilizer to fuel tank to minimize the formation of fuel gum deposits during storage.

2.

Run engine at least 10 minutes after adding stabilizer to allow it to enter the fuel system.

3. Next shut off engine.

4.

Disconnect the spark plug wire and remove the spark plug.

5.

Add one teaspoon of oil through the spark plug hole.

6.

Place rag over spark plug hole and pull the recoil a few times to lubricate the combustion chamber.

7. Replace the spark plug, but do not connect the spark plug wire.

NOTE: If a fuel stabilizer is not used, all gasoline must be drained from the tank and carburetor to prevent gum deposits from forming on these parts and causing possible malfunction of the engine.

GENERATOR

1. Clean the generator as outlined in the Maintenance Section on this manual.

2.

Check that cooling air slots and openings on generator are open and unobstructed.

BATTERY

1. Store battery as described by the battery manufacturer.

NOTE: After storing battery for a long period of time it may lose its charge. If the battery loses its charge, manually start the engine with the battery connected. The engine will recharge the battery as it runs.

21- ENG D28469

WATTAGE CALCULATIONS

IMPORTANT

Never exceed the rated capacity of your generator. Serious damage to the generator or appliance could result from an overload.

1.

Starting and running wattage requirements should always be calculated when matching a generators wattage capacity to the appliance or tool.

2.

There are two types of electrical appliances that can be powered by your generator:

A.

Items such as radios, light bulbs, television sets, and microwaves have a "resistive load". Starting wattage and running wattage are the same.

B.

Items such as refrigerators, air compressors, washer, dryer, and hand tools that use an electrical motor have an "inductive load".

Inductive load appliances and tools require approximately 2 to 4 times the listed wattage for starting the equipment. This initial load only lasts for a few seconds on start-up but is very important when figuring your total wattage to be used.

C.

Always start your largest electric motor first, and then plug in other items, one at a time.

NOTE: On 120-volt loads the maximum starting wattage should NOT exceed one half of the rated generator wattage. Example: a 5000 rated wattage generator = 2500 maximum starting wattage.

DETERMINING WATTAGE REQUIREMENTS

Before operating this generator list all of the appliances and/or tools that are going to operate at the same time. (Then determine the starting wattage requirements and the running wattage requirements by following example and/or refer to household wattage calculator.)

1.

First total the running wattage of all appliances and/or tools that will be operated at the same time.

Running Watts Starting Watts

Example 1:

Lights =

Television

Slow Cooker

=

=

300 Watts

250 Watts

=650 Watts

0

0

0

TOTAL 0

2.

Next the starting wattages of any appliances and/or tools that will start and stop during operation.

Running Watts Starting Watts

Example 2:

Small Refrigerator 500 Watts

TOTAL =500 Watts

2000 Watts

2000 Watts

D28469 22- ENG

3.

The running wattage of examples 1 & 2 totals 1150 watts. The starting wattage of the small refrigerator is 2000 watts which is 1500 watts more than the running watts. Take this difference of 1500 starting watts from the refrigerator and add to the total running watts of 1150.

Example 3: 1500 Starting Watts

1150 Running Watts

TOTAL =2650 Total Watts

Generator must have a maximum capacity of at least 2650 watts.

STARTING WATTAGE REQUIREMENTS

1.

Some appliances and tools will list on the motor nameplate the starting and running voltage and amperage requirements. Use the following formula to convert voltage and amperage to wattage:

Volts X Amp = Watts

Example: 120 volts x 10 amps = 1200 watts

2.

To determine the approximate starting wattage requirement for most appliances and tools with inductive type motors, multiply the wattage that was calculated by 2 to 4 times to assure adequate generator capacity. If the nameplate information is not available use the values on the following chart as a guide.

3.

Remember that the starting and running wattage for resistive loads are the same. (Example: a 100 watt light bulb requires only 100 watts to start.)

Most resistive loads will be listed in wattage.

Application Guide

3/8” Hand Drill

Jigsaw

(1/3 HP) Airless Sprayer

6” Bench Grinder

Belt Sander

Demolition Hammer

7-1/4” Circular Saw

(Small) Air Compressor

Light Bulb

Home Security

Television

Microwave

Toaster Oven

(5,000 BTU) Portable Heater

Furnace Fan

Refrigerator/Freezer

Sump Pump

Clothes Washer

Water Heater

(30,000 BTU) Air Conditioner

(12V DC) Battery Charger

Radio

Slow Cooker

Electric Blanket

Electric Skillet

Coffee Maker

Small Refrigerator

The wattage ratings shown are averages - actual wattage may vary.

To select the right generator for your needs, total the wattage of the items to be run at the same time.

10

0

250 500 1000 20

00

3000 4000 5000 6000 7000 8000 9000 10000

WATTAGE Run Start

23- ENG D28469

HOUSEHOLD WATTAGE CALCULATOR

DEVICES WITH HIGH STARTING (INDUCTIVE)LOADS

RUN WATTS TIMES (X) START FACTOR

APPLIANCE OR

LOAD DEVICE*

TYPICAL DEVICE

WATTAGE**

TOTAL

800

600

2400

1000

800

1000 x x x x x x

3

3

3

2

3

2

REFRIGERATOR/

FREEZER

=

SMALL REFRIGERATOR

=

AIR COND.(ROOM) =

SUMP PUMP 1/2 HP =

FURNACE FAN 1/3 HP

=

WELL PUMP 1/2 HP

=

2400

2000

2400

1800

7200

2000

=

=

=

=

=

=

CAUTION !!

HOT PLATE = 1500

DO NOT CONNECT VOLTAGE SENSITIVE

ELECTRONIC EQUIPMENT (TV SET, COMPUTER,

ETC.) DIRECTLY TO YOUR GENERATOR. IF YOU USE

THE GENERATOR TO POWER SENSITIVE EQUIPMENT

YOU MUST USE A U.L. LISTED VOLTAGE SURGE

PROTECTOR.

NOTICE: FAILURE TO USE A U.L. LISTED VOLTAGE

SURGE PROTECTOR WILL DAMAGE YOUR

EQUIPMENT AND VOID YOUR WARRANTY.

THE IDLE CONTROL MUST BE IN THE

OFF POSITION WHEN OPERATING

LARGE MOTOR LOADS (FREEZERS,

REFRIGERATORS,ETC.) OR VOLTAGE

SENSITIVE ELECTRONIC EQUIPMENT

(TV, COMPUTERS, ETC.)

TELEVISION

MICROWAVE

SPACE HEATER

=

=

=

300

800

1500

=

=

=

LIGHTING

60 WATT BULBS

75 WATT BULBS

100 WATT BULBS

300 WATT BULBS

WATER HEATER = 4000

WATTS

60

75

100

300 x x x x

TIMES NUMBER

OF BULBS

=

=

=

=

=

=

*FOR PRODUCTS NOT

LISTED REFER TO

CALCULATION

INSTRUCTIONS

**AVERAGE VALUES -

ACTUAL INDIVIDUAL

DEVICE VOLTAGES MAY

BE HIGHER OR LOWER

CAUTION !!

ELECTRIC LOAD GRAND TOTAL

THIS TOTAL MUST BE LESS THAN YOUR GENERATOR RATING

WATTAGE RATING OF YOUR GENERATOR

THIS TOTAL MUST BE GREATER THAN YOUR HOUSEHOLD WATTAGE LOAD

D28469 24- ENG

TROUBLESHOOTING GUIDE

PROBLEM

Engine will not start

No electrical output

Repeated circuit breaker tripping

Generator overheating

No auto idle

CAUSE CORRECTION

1.

Low on fuel or oil.

2.

Ignition switch in "Off" position.

3.

Faulty spark plug.

4.

Choke in wrong position.

5.

Fuel shut-off valve in closed position

6.

Unit loaded during startup.

7. Spark plug wire loose.

1.

Faulty receptacle.

1.

Add fuel or oil.

2.

Turn to "ON" position

3.

Replace spark plug.

4.

Adjust choke accordingly.

5.

Open fuel shut-off valve.

6.

7.

Remove load from unit.

Attach wire to spark plug.

1.

Have Service Center replace.

2.

Depress and reset.

2.

Circuit breaker kicked out.

3.

Defective capacitor.

3.

Have Service Center replace capacitor.

4.

Repair or replace cord.

4.

Faulty power cord.

5. GFCI switch breaker kicked out (if equipped)

1.

Overload

2.

Faulty cords or equipment

5. Depress and reset

1.

Reduce load.

2.

Check for damaged, bare, or frayed wires on equipment. Replace.

1.

Generator overloaded.

1.

Reduce load.

2.

Insufficient ventilation.

2.

Move to adequate supply of fresh air.

1. Have Service Center replace.

2. Faulty idle control switch 2. Have Service Center replace.

3. Faulty windings in stator

4. Faulty circuit board

5. Faulty wire harness

3. Have Service Center replace.

4. Have Service Center replace.

5. Have Service Center replace.

DC does not have power with the circuit breaker depressed

2. Faulty windings in stator

3. Faulty wire harness

1. Have Service Center replace.

2. Have Service Center replace.

3. Have Service Center replace.

25- ENG D28469

LIMITED WARRANTY

PORTER-CABLE CORPORATION warrants to the original purchaser that all products covered under this warranty are free from defects in material and workmanship. Products covered under this warranty include air compressors, air tools, service parts, pressure washers, and generators, which have the following warranty periods:

3 YEARS - Limited warranty on 2-stage oil-free air compressor pumps that operate at 1725 RPM.

2 YEARS - Limited warranty on oil-lubricated air compressor pumps.

1 YEAR - Limited warranty on all other air compressor components.

2 YEARS - Limited warranty on electric generator alternators.

1 YEAR - Limited warranty on other generator components.

2 YEARS - Limited warranty on pneumatic air tools as described in Porter-Cable general catalog.

1 YEAR - Limited warranty on pressure washers used in consumer applications (i.e. personal residential household usage only).

90 DAY - Pressure washers used for commercial applications (income producing) and service parts.

1 YEAR - Limited warranty on all accessories.

Porter-Cable will repair or replace, at Porter-Cable's option, products or components which have failed within the warranty period. Service will be scheduled according to the normal work flow and business hours at the service center location, and the availability of replacement parts. All decisions of Porter-

Cable Corporation with regard to this limited warranty shall be final.

This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

RESPONSIBILITY OF ORIGINAL PURCHASER (initial User):

• To process a warranty claim on this product, DO NOT return it to the retailer. The product must be evaluated by an Porter-Cable Authorized Warranty Service Center. For the location of the nearest Porter-

Cable Authorized Warranty Service Center call 1-888-559-8550, 24 hours a day, 7 days a week.

• Retain original cash register sales receipt as proof of purchase for warranty work.

• Use reasonable care in the operation and maintenance of the product as described in the Owners

Manual(s).

• Deliver or ship the product to the nearest Porter-Cable Authorized Warranty Service Center. Freight costs, if any, must be paid by the purchaser.

• Air compressors with 60 and 80 gallon tanks will be inspected at the site of installation. Contact the nearest Porter-Cable Authorized Warranty Service Center that provides on-site service calls, for service call arrangements.

• If the purchaser does not receive satisfactory results from the Porter-Cable Authorized Warranty Service

Center, the purchaser should contact Porter-Cable.

THIS WARRANTY DOES NOT COVER:

• Merchandise sold as reconditioned, used as rental equipment, and floor or display models.

• Merchandise that has become damaged or inoperative because of ordinary wear, misuse*, cold, heat, rain, excessive humidity, freeze damage, use of improper chemicals, negligence, accident, failure to operate the product in accordance with the instructions provided in the Owners Manual(s) supplied with the product, improper maintenance, the use of accessories or attachments not recommended by Porter-

Cable, or unauthorized repair or alterations.

* An air compressor that pumps air more than 50% during a one hour period is considered misuse because the air compressor is undersized for the required air demand.

• Repair and transportation costs of merchandise determined not to be defective.

• Costs associated with assembly, required oil, adjustments or other installation and start-up costs.

• Expendable parts or accessories supplied with the product which are expected to become inoperative or unuseable after a reasonable period of use, including but not limited to sanding disks or pads, saw and shear blades, grinding stones, springs, chisels, nozzles, o-rings, air jets, washers and similar accessories.

• Merchandise sold by Porter-Cable which has been manufactured by and identified as the product of another company, such as gasoline engines. The product manufacturer's warranty, if any, will apply.

ANY INCIDENTAL, INDIRECT OR CONSEQUENTIAL LOSS, DAMAGE, OR EXPENSE THAT MAY

RESULT FROM ANY DEFECT, FAILURE OR MALFUNCTION OF THE PRODUCT IS NOT COVERED BY

THIS WARRANTY. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.

IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY OR FITNESS FOR A

PARTICULAR PURPOSE, ARE LIMITED TO ONE YEAR FROM THE DATE OF ORIGINAL PURCHASE.

Some states do not allow limitations on how long an implied warranty lasts, so the above limitations may not apply to you.

D28469

Porter-Cable Corporation

Jackson, TN USA

1-888-559-8550

26- ENG

NOTES

27- ENG D28469

QUICK FACTS

CALL 1-888-559-8550 TO FIND A LOCAL AUTHORIZED SERVICE CENTER

NEAR YOU FOR REPAIRS AND SERVICE PART PURCHASES

ENGINE

GAS

ENGINE OIL

WATTAGE

Use clean, fresh gasoline with a minimum 87 octane rating. Do not add gasoline during or immediately after use.

Refer to engine owner's manual for oil recommendations.

Most generators are equipped with a low-oil shutdown. If the oil is low or if the Generator is not level, the engine will not start.

Make wattage calculations before use. Refer to general operator's manual for further instructions.

WIRING

BATTERY

VOLT REG.

ENGINE

STORAGE

Contact an electrician for any wiring instructions. If wiring into a house, a double-throw transfer switch and a heavy duty cord set must be used.

Use a standard (12V) lawn and garden battery with a minimum of 45 A.H. or 210 CCA.

The voltage and frequency are regulated by the rpm's of the engine. Do not adjust the throttle or governor to achieve higher performance. This will only alter the factory Pre-set settings and damage anything connected to the generator.

Be sure a volt/amp surge protector is used when sensitive electronic equipment is used, such as: televisions, computers, stereos, and etc… The damage of such equipment without the use of a protector WILL NOT be covered under warranty.

Do not adjust or attempt maintenance without consulting engine manual or an authorized engine service center.

Add stabilizer to fuel tank and run engine for 5 minutes before storage.

When in long term storage, operate the generator every 60 days for at least 10 minutes with a load on it. This will prevent the loss of residual magnetism that produces the electricity.

Allow the generator to run 5 minutes at no load for the engine and the gen head to stabilize.

OPERATION

Make sure the adequate size of extension cord is used. Refer to the Grounding Instructions/Extension Cord section of the owners manual.

If the generator is operating equipment that is drawing half of the rated watts it is considered 50% load. Using all of the rated watts is considered 100% load.

D28469

ALWAYS REFER TO THE MANUALS SUPPLIED WITH THIS UNIT

28- ENG

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Frequently Answers and Questions

What should you do to prevent electrocution and fire hazard while connecting the generator to a building's electrical system?
To connect to a structure's electrical system safely, have a qualified electrician install a Double-Throw Transfer Switch following local ordinances.
What should you do to prevent fire hazard when operating the generator?
Operate the generator in a clean, dry, well-ventilated area at least four feet from any building or object. Do not operate indoors or in confined areas.
How can you prevent fuel spillage during transportation?
If the generator has a fuel shut-off valve, turn it off before transporting. If it doesn't, drain the fuel tank before moving the generator.
How to prevent breathing-inhalation hazard?
Operate the generator in a clean, dry, well-ventilated area. Never operate it in enclosed spaces like garages, basements, storage sheds, or any location occupied by humans or animals.

advertisement