Robic SC-636W-Heat Stress and Comfort Index Instruction manual

Add to My manuals
2 Pages

advertisement

Robic SC-636W-Heat Stress and Comfort Index Instruction manual | Manualzz

Suitable Mode: C5097-PD13377M SIZE: A4

Robic SC-636W INSTRUCTION GUIDE

Thank you for purchasing the Robic SC-636W-Heat Stress and

Comfort Index Stopwatch. Your purchase brings you a reliable,

World-Class Timer which measures performance for a wide array of sports and many other activities. Please become familiar with its operation so you can enjoy its many fine features:

FEATURES:

• Display time, date, temperature, humidity and Dew Point

• 10 Hour Coutdown Timer with 1/100 second resolution

• Display Heat Index and Comfort Index Levels

• 1/100 second stopwatch for 10 hours

• Fastest lap/Lowest lap/Average lap record

• Lap Counter to 99 with 30 Lap/Split Memory Recall

FUNCTION KEYS:

MODE key:

- In normal time mode, press it to switch among normal time mode, Temperature and Humidity mode, Heat Index mode, Dew

Point mode, LAP mode, SPLIT mode, countdown timer mode and alarm time mode.

- In setting mode, press it to save and exit the setting mode.

- In recall mode, press it to return to the lap/split mode.

RECALL key:

- In alarm time mode/normal time mode/countdown timer mode, press and hold it for 2 seconds to enter setting mode.

- In setting mode, press it to save and exit the setting.

- In lap/split mode, press it to enter recall mode to check the fastest lap record, lowest lap record and average lap record.

START·STOP key:

- In lap/split/countdown timer mode, press it to start/stop time counting.

- In recall mode, press it to check the lap and split time records;

Press it again to check the records upwards.

- In alarm time mode, press it to turn on/off the alarm.

- In normal time mode, press it to turn on/off key tone.

- In setting mode, press it to adjust the setting value of flashing digit; Or press it without releasing to speed up the setting.

- In Temperature and Humidity mode/Heat Index mode/Dew Point mode, press it to switch between °C / °F.

LAP·SPLIT/RESET key:

- In lap/split mode, during time counting period, press it to record the current lap/split number and time.

- When the time counting is stopped, press it to clear the time value.

- In recall mode, press it to check the lap and split time records.

Press it again to check the records downwards.

- In normal time mode, press it to turn on /off key tone.

- In setting mode, press it to step the setting items.

- In Temperature and Humidity mode/Heat Index mode/Dew Point mode, press it to switch between °C / °F.

HEAT INDEX/COMFORT INDEX key:

- Press it to switch between Heat Index and Comfort Index.

3 4

PRODUCT DESCRIPTION 2

5

1.LCD display

2.LAP·SPLIT/RESET key

3.RECALL key

4.MODE key

5.START·STOP key

6.HEAT INDEX/COMFORT INDEX key

1

1

6

FUNCTION MODES

Normal time mode

Alarm time mode

Humidity and Temperature mode

Heat Index mode

DEW Point mode

Lap mode

Split mode

Countdown timer mode

SET THE TIME AND CALENDAR

1.

In normal time mode, press and hold “RECALL” key for 2 seconds to enter time setting mode with the second digit flashing.

2.

Press “START·STOP” key to adjust the value of the flashing digit.

3.

Press “LAP·SPLIT/RESET” key to step the setting items in this sequence: Second > Minute > Hour > Year > Month > Date >

12/24 hour format.

4.

Press “MODE” or “RECALL” key to save and exit the setting mode.

Normal time mode Second setting Minute setting

Hour format setting Hour setting

Date setting

SET THE ALARM TIME

Month setting Year setting

1.

In alarm time mode, press and hold “RECALL” key for 2 seconds to enter alarm time setting mode with the Hour digit flashing.

2.

Press “START·STOP” key to adjust the value of the flashing digit.

3.

Press “LAP·SPLIT/RESET” key to step the setting items in this sequence: Hour > Minute.

4.

Press “MODE” or “RECALL” key to save and exit the setting mode.

Alarm time mode Hour setting Minute setting Alarm time mode

Note:

1. It will automatically turn on the alarm function when enter alarm time setting mode. Or you can press “START·STOP” key to turn on/ off it in alarm time mode.

2. When the alarm sounds, press any key to turn off the sound, or it will automatically turn off if there is no any operation in 30 seconds.

COUNTDOWN TIME SETTING

1.

In countdown timer mode, press and hold “RECALL” key for 2 seconds to enter countdown time setting mode with the Hour digit flashing.

2.

Press “START·STOP” key to adjust the value of the flashing digit.

3.

Press “LAP·SPLIT/RESET” key to step the setting items in this sequence: Hour > Minute > Second.

4.

Press “MODE” or “RECALL” key to save and exit the setting mode.

Countdown timer mode Hour setting Minute setting Second setting

Note:

1. The maximum time you set can be 9:59’59”

00

.

Countdown timer mode

USING COUNTDOWN FUNCTION

1.

Set the countdown time as described in the above section, or press “LAP·SPLIT/RESET” to clear the value to 0:00’00”

00

for countdown the time from 9:59’59”

00

.

2.

Press “START·STOP” key to start/stop the counting.

3.

When the time counting is stopped, press “LAP·SPLIT/RESET” key to clear the value to 0:00’00”

00

.

Note:

1. It will countdown again and record the counting cycle times as soon as it finishes the counting.

LAP TIME MEASUREMENT

Using this function, you can record the time you spend on each lap.

For example, you measure 3 lap time, do the following:

1.

Press “MODE” key to select lap mode with the icon “LAP” displayed on the LCD.

2.

Press “LAP·SPLIT/RESET” key to clear the value to 0:00’00”

00

.

3.

Press “START·STOP” key to start/stop the measurement.

4.

Press “LAP·SPLIT/RESET” key to record the time you spend on each lap when you finish 1 st lap, 2 nd lap and 3 rd lap.

5.

Press “START·STOP” key to stop the measurement with the icon “STOP” displays on the LCD.

Note:

1. The maximum time you can measure is 9:59’59”

00.

It will start a new measurement when it reach 9:59’59”

00.

2. The following picture shows the way of lap time measurement.

0 1 2 3 (Lap)

SLIPT TIME MEASUREMENT

Using this function, you can record the time you spend on every split. For example, you measure 3 split time, do the following:

1.

Press “MODE” key to select split mode with the icon “SPLIT” displays on the LCD.

2.

Press “LAP·SPLIT/RESET” key to clear the value to 0:00’00”

00

.

3.

Press “START·STOP” key to start/stop the measurement.

4.

Press “LAP·SPLIT/RESET” key to record the time you spend on each lap when you finish 1 split, 2 split and 3 split.

5.

Press “START·STOP” key to stop the measurement with the icon “STOP” displays on the LCD.

Note:

1. The maximum time you can measure is 9:59’59”

00.

It will start a new measurement when it reach 9:59’59”

00.

2. The following picture shows the way of split time measurement.

0 1 2 3

(Split)

RECALLING LAP/SPLIT RECORDS

1.

During the time measurement period or stop the measurement, press “RECALL” key to enter recall mode to check the fastest lap, slowest lap and average lap. And press “LAP·SPLIT/RESET” key or “START·STOP” key to turn to check the lap number and time record downwards or upwards.

2.

In recall mode, press “MODE” key to return to time measurement mode.

Note:

1.The sports timer can display up to 99-lap/split time records, but only memory the first 30 records.

2.The lap and split time records will be displayed together when you recall the lap or split records.

CHECK THE HEAT INDEX/COMFORT INDEX

You may press “HEAT INDEX/COMFORT INDEX” key to select the desired mode to check the Heat Index or Comfort Index.

Heat Index mode Comfort Index mode

Note:

You can check the Heat Index according to following reference table.

Heat Index

135

130

0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100

120 126

117 122 131

Temp

(°F)

125

120

115

111 116 123 131 141

107 111 116 123 130 139 148

105 107 111 115 120 127 135 143 151

99 102 105 108 112 117 123 130 137 143 150 110

105

100

95

90

85

80

75

70

95 97

91 93 95 97 99

87 88 90 91 93 94 96 98

83 84 85

78

73

79

74

100 102 105 109 113 118

80

75

86

81

76

87

82

77

88 90 91 93 94 96 98 100 102 106 109 113 117 122 126 131

83

77

84

78

85

79

123 129 135 142 149

101104 107 110 115 120 126 132 138 144 150

101104 107 110 114 119 124 130 136 140 150

86

79

87

80

88

81

89

81

90

82

91

83

93

84

95

85

97

86

99

87

102

88

105

89

108

90

69 69 70 71 72 72 73 73 74 74 75 75 76 76 77 77 78 78 79 79 80

64 64 65 65 66 66 67 67 68 68 69 69 70 70 70 70 71 71 71 71 72

Heat Index

Extreme danger:

above 130°F

Danger:

106 ~ 129°F

Extreme caution:

90 ~ 105°F

Caution:

80 ~ 90°F

No display:

below 79°F

KEY TONE SETTING

In normal time mode, press “LAP·SPLIT/RESET” key or

“START·STOP” key to turn on/off the key tone with the icon “ ” appears or disappears from the LCD.

BATTERY REPLACEMENT

If there is no display on the LCD or the display becomes dim, remove the screws at the back of the unit and replace with one new CR2032 battery at once.

Note:

Attention! Please dispose of the used unit or battery in an ecologically safe manner.

4

advertisement

Related manuals

advertisement